Loading...
20211199 344 Lake Solar Electrical System Agenda DocuSign Envelope ID:8264F79C-DB15-4C1 E-A988-E1 FOFF135152 ** IFOR OFFICE USE1 I Irk!V V V V I\I I I LIN/ -F L I V Pl I I V I V J V V I L L INV I I.J L P1 V V L P T E D �nTOG4 CITY OF SARATOGA SPRINGS (Application#) A DESIGN REVIEW COMMISSION .c� ) - CITY HALL-474 BROADWAY (Date received) w' ' SARATOGA SPRINGS, NEW YORK 12866-2296 • zcTEL: 518-587-3550 X2533 �RPORAjEfl www.saratoga-springs.org (Project Title) APPLICATION FOR: ARCHITECTURAL/HISTORIC REVIEW Staff Review APPLICANT(S)* OWNER(S) (if not applicant) ATTORNEY/(GENT) Name Robert Spring Robert Spring Loralee Reidy (SunCommon) Address 344 Lake Avenue 344 Lake Avenue 13 Hook Rd Saratoga Springs, NY 12866 Saratoga Springs, NY 12866 Rhinebeck, NY 12572 Phone 518-584-0596 / 518-584-0596 / 845-332-8800/ Email roberttspring@gmail.com roberttspring@gmail.com loralee.reidy@suncommon.com Identify primary contact person: 0 Applicant 0 Owner E Attorney/Agent *An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: E Owner 0 Lessee 0 Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: 344 Lake Avenue, Saratoga Springs, NY Tax Parcel #: 166.15 1 - 1(for example: /65.52-4-37) Date Acquired by Owner: Current Zoning District: U R5 Property use: a Residential 0 Non-residential/mixed-use Type of Review: 0 Architectural 0 Historic 0 Extension/modification (of current approval) Summary description of proposed action: Installation of a roof mounted solar electric system consisting of(22) LG425QAK-A6 modules & (22) Enphase IQ7A-72-2-US microinverters. Has a previous application been filed with the DRC for this property? IR No 0 Yes—date(s)? -App. No.(s)? Revised 01/2021 DocuSign Envelope ID:8264F79C-DB15-4C1 E-A988-E1 FOFF135152 **A "complete" application consists of 1 hard copy(original) , and I electronic copy of application &ALL other materials as required below: New Construction /Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ Site plan, drawn to scale, showing existing&proposed construction, property lines&dimensions, required &proposed setbacks&lot coverage, site features (fences,walks,trees, etc.); on no larger than 2'x3' sheet—smaller preferred if legible ❑ Elevation drawings showing design of all sides of existing&proposed construction—label dimensions, colors, materials, lighting(fixture &lamp type,wattage), etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ❑ Floor plans for proposed structure;on sheet no larger than 2'x3'—smaller permitted if legible ❑ Product literature,specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ▪ Color photographs showing site/exterior details of existing structures and that illustrate affected features ▪ Elevation drawings showing all sides of existing&proposed construction—label dimensions, colors, materials, lighting(fixture&lamp type,wattage),etc. - include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ▪ Product literature,specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks:UR-I &INST-HTR=30';UR-4=25';UR-2,UR-3&NCUD-I=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing&proposed construction: include property lines&dimensions, required &proposed setbacks&lot coverage, site features (fences,walks,trees, etc.) street names, compass bearing&scale; no larger than 2'x3'sheet—smaller preferred if legible ❑ Product literature, specifications and samples of proposed materials and colors Signage/Awnings ❑ Color photographs showing site/exterior details of existing structures, and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I"x 17" ❑ Scaled illustration of proposed sign/awning structure and lettering(front view&profile): include all dimensions of structure;type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method, and location ❑ Product literature, specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing and any proposed structures- include dimensions,setbacks, street names, compass bearing,and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of"architectural/historical significance",demonstrate "good cause"why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing" structure in a National Register district(contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions, setbacks,street names, compass bearing, and scale ❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 DocuSign Envelope ID:8264F79C-DB15-4C1 E-A988-E1 FOFF135152 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org.App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form ❑ Applicants proposing the following must complete"Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/perm its_ej_operations_pdf/seaf partone.pdf): -Construction or expansion of a multi-family residential structure(4 units +) -Construction or expansion (exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? E No 0 Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we,the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. �DocuSigned by: Owner Signature:_ 1 �2 Date: 10/26/2021 —6737235A5ElD4F2... Owner Signature: Date: Revised 01/2021 DocuSign Envelope ID:8264F79C-DB15-4C1 E-A988-E1 FOFF135152 0G4 6'A CITY OF SARATOGA SPRINGS A . DESIGN REVIEW COMMISSION •AptiAour City Hall -474 Broadway { •' • Saratoga Springs, New York 12866 ORPORATEfl Tel:518-587-3550 x2533 www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/HISTORIC REVIEW APPLICATION I. ELIGIBILITY:An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit • Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure • any material change to exterior of a structure including: • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, Within a non-residential zoning district: • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. • Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note—Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. Revised 01/2021 DocuSign Envelope ID:8264F79C-DB15-4C1 E-A988-E1 FOFF135152 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height—consistent with historic form and context of site and surrounding properties • Scale— relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front facade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other facade elements • Directional Expression —compatibility with horizontal &vertical expression of surrounding structures • Massing & Open Space— relationship of structure to open space between it and adjoining buildings • Setback—compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Building materials - Color— (in non-residential zoning districts only) 5. DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come,first-served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 DocuSign Envelope ID:8264F79C-DB15-4C1 E-A988-E1 FOFF135152 2021 LAND USE BOARD FEE WORKSHEET OPED Fees Type 2021 Fee Application to Zoning Board of Appeals[1][2] TOTAL #VARIANCE Use Variance $1100+$50/app Area Variance-Residential $275/var+$50/app+$125 eachadd'I variance Area Variance-Multi-Family,Comm,Mixed-Use $660/var+$50/app+$200 eachadd'I variance Interpretations $550+$50/app Post-Work Application Fee Add 50%App fee+$50/app Variance extensions 50%ofAppfee+$50/app Application to Design Review Commission[1] TOTAL #STRUCTURE Demolition I $385 Residential Structures Principal $55 Accessory $55 Extension $35 Modification 55 $55 Multi-Family,Comm,Mixed-Use Structures Sketch $165 Principal $550 Extension $200 Modification $330 Multi-Family,Comm,Mixed-Use Accessory,Signs,Awnings Principal $140 Extension $75 Modification $140 Post-Work Application Fee Add 50%App fee Application to Planning Board[1] TOTAL #STRUCTURE Special Use Permit[2] $990+$50/app Special UsePermit-extension $330 Special UsePermit-modification[2] $450+$50/app Site Plan Review-incl.PUD: Sketch Plan $330 Residential $330+$200/unit Residential-extension $200 Residential-modification $400 Non-residential $660+$130/1000 sf Non-Residential-extension $300 Non-Residential-modification $650 Subdivision-incl.PUD: TOTAL #LOTS Sketch Plan I $330 Preliminary Approval[2] Residential:1-5 lots $660+$50/app Residential:6-10 lots $990+$50/app Residential:11-20 lots $1320+$50/app Residential:21+lots $1650+50/app Residential-extension $330 Final Approval[2] Residential $1320+$175/lot+$50/app Non-Residential $2000/lot+$50/app Final Approval Modification[2] Residential $330+$50/app Non-Residential $550+$50/app Final Approval Extension Residential $135 Non-Residential $330 Other: TOTAL #LOT/ACRE Post-Work Application Fee Add 50%App fee Lot Line Adjustment $350 Letter of Credit-modification or extension $440 Letter of Credit-collection up to 1%ofLoC Recreation Fee $2000/lotorunit Land Disturbance $660+$55/acre SEQRA EIS Review(Draft&Final) TBD Legal Noticing if PB requires Public Hearing $50/app [1] Fees are based on per structure,except where noted. $55.00 TOTAL DUE [2] Legal ad required;includes City processing and publishing For Administrative Use Total Paid at Intake Revised Fee Balance Due / / Balance Paid Staff approval SOLACOM-01 CPERKINS '`,CCPRCir CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 10/26/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Camille Perkins NAME: AssuredPartners New England,Inc. PHONE FAX 38 Eastwood Drive,Suite 105 (A/C,No,Ext). (802)456-4463 (A/C,No):(802)456-4463 South Burlington,VT 05403 ADDRESS:ICamille.Perkins@AssuredPartners.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Ohio Security Insurance Company 24082 INSURED INSURER B:Ohio Casualty Ins. Co. 24074 Solar Communities Inc.dba SunCommon,Hudson Valley INSURER C: Clean Energy,Inc dba Husdon Solar 442 US Route 2 INSURER D: Waterbury,VT 05676 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR WPOLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD VD (MM/DD/YYYY) (MM/DD/YYYY) A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR BKS(21)58362800RENTED 12/30/2020 12/30/2021 PREMISESO(Ea occurrence) $ 500,000 MED EXP(Any one person) $ 15,000 PERSONAL&ADV INJURY $ 1,000,000 GE 'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY JECT LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ A AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) X ANY AUTO BAS(21)58362800 12/30/2020 12/30/2021 BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ AUTOS ONLY NON-OWNED ONLYY PROPERTY DAMAGE (Per ccident B X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE USO(21)58362800 12/30/2020 12/30/2021 AGGREGATE $ 5,000,000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITYY/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) The Certificate Holder is included as an Additional Insured,when required by written contract,per the terms,conditions and exclusions of the referenced General Liability policy. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Cityof Saratoga Springs THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 9ACCORDANCE WITH THE POLICY PROVISIONS. 484 Broadway Saratoga Springs,NY 12866 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID'.06E958FE-DD16-472F-9C6O-DSEAAD6A687E DRAWING LIST SCOPE OF WORK AERIAL PARCEL VIEW(SCALE:1/16"=1) PV-01 TITLE SHEET ARRAY(S):R15TALIATION OF FLUSH-MOUNTED ARRAYS ON SOUTH - I _ ROOF(R1),EAST ROOF(R2),AND WEST ROOF(R3). -41111.11.0. PV-02 SITE PIAN CONDUIT RUNS:SUNCOMMON TO PERFORM PRE-WIRE DURING PV-03 ARRAY LAYOUT NEW CONSTRUCTION PRIOR TO INTERIOR WALLS CLOSING. _ _.__ _ ill CONDUIT/CABLE RUNS TO BE DETERMINED DURING PRE-WIRE f PV-04 ELECTRICAL DRAWING INSTALLATION. ELECTRICAL EQUIPMENT:INSTALLATION OF AC COMBINER AND PRODUCTION METER ON NORTH INTERIOR WALL IN HOUSEK I BASEMENT.AC DISCONNECT ON FAST EXTERIOR HOUSE WALL. I • SUNCOMMON TO INSTALL SOIADECKS(51,52,53)DURING I PRE-WIRE INSTALLATION.. I V INTERCONNECTION I ELECTRICAL SCOPE:INTERCONNECT SOLAR ,�' -.' '• PV SYSTEM VIA BACKFEED BREAKER IN THE MAN SERVICE PANEL -• -• • -- IN. BAR.CUSTOMER LS TO UPGRADE MAIN SERVICE PANEL AND • I I COMPLETE ROOF It15TALLATION BEFORE SUNCOMMON PRE-WIRE f �" . INSTALLATION.SUNCOMMON TO INSTALL NEW 2'X 4'COLLAR `■ i. TIES BETWEEN UPPER RAFTERS UNDER EXISTING ROOF PLANE'S ` •�I *. ` ';" X- o , r I �, � (R28,R3)TO MEET BUILDING CODE STANDARDS. R t •J. rr ,• 1 ,�•- w PRELIMINARY DESIGN NOTES:PRELIMINARY DESIGN IS SUBJECT I' ZONING DETAILS TO CHANGE AFTER SITE EVALUATION REVISIT.SUNCOMMON TO _ PERFORM REVISIT WHEN ROOF AND ELECTRICAL WORK ARE COMPLETED.SUNCOMMON TO CONFIRM SHADE REPORTS,ROOF ' I r . : A ZONING CRSS: LIR, MEASUREMENTS,ROOF TYPE,AND TO RETAKE NEW INTERIOR PHOTOS DURING REVISIT. ai 11111 '1 TAX I.D.#: 166.15-1-1 • 1. K is aviolalion of New York Stale Education Law (' ' • 0' DESIGN CRITERIA Mick 145 for any person,unless acting under - ��� . the direct supervsi0n of a licensed professional " . en9neer,to alter the drawing in any way. 4 8450 WIND SPEED: 115 MPH •� V' _ O r S�VF-FOIL' . . _ - •' WIND EXPOSURE CATEGORY B •• E GROUND SNOW LOAD NTPSF �ep'''''.2.'_%"2_.-t'''w . • 17• l� r• 1 14 t ASCE CODE 7-10 o�s'-- • - • All S WA°, li. APPLICABLE CODES • 419�I • r+ CONTRACTOR TO ENSURE THAT THE ENERGY STORAGE SYSTEM IS INSTALLED IN COMPLIANCE WITH SECTION R327 OF ME 2020 RESIDENTIAL CODE OF NEW , • YORK STATE AND,IF APPLICABLE,SECTION 1.OF THE 2020 FIRE CODE OF NEW YORK STATE. -a. • CT 4,7‘.k u PRD)FLoc APPLICABLE CODES: RE D RD o�sr M o iA IOa awD TITLE SHEETSPRING oc sYsrEM SNE nwPIMODDLE Lam Moon: rzn Ec4zOX-SA SERVICE MEN SUNCUMMUN 3aa LAKE AVE szE nw,: RTER cam MODE: an ENSHASEma-72-SLIS PV-07 13 HOOK ROAD SARATOGA SPRINGS,NY,12866 CONTRACTOR TO PERFORM SERVICE svE CA3_ MxaarwERTERS ._� RHINEBECK,NEW YORK 12572 CITY OF SARATOGA,INSIDE ALL WORK IN ACCORDANCE (B66)-452-7652 SARATOGA COUNTY WITH THE 2020 RESIDENTIAL 1 OF 4 suncommon PHONE:(518)584-0596 CODE OF NEW YORK STATE. SUNCOMMON CONFIDENTIAL AND PROPRIETARY t DocuSign Envelope ID'.06E958FE-DD16-472F-9C6O-D1EAAD6A687E It is a violation of New York State Education Law LEGEND STREET *tee 145 for any person,unless acing wad er. eoNStonOenuprofession* engine talter ha drawing m+NW wel. S.apF NEW yp STRUCTURE OR ROAD hRP(pfF B.IRYsyq,F EXISTING VEGETATION MAIN SERVICE PANEL ',zeros," AC COMBINER, PV METER C04981r5C4E7 UTILITY METER AC DISCONNECT, ROOF (R3) "RAPID SHUTDOWN INITIATION Mil _. DEVICE PER NEC 690.12(C)" TRENCH DETAIL OF APPLICABLE) 6' RADE 1 tall; _ WARNING TAPE a 111'-6" SCH.40 PVC CONDUIT(2 ROOF (R2) FOR REFERENCE -SIZES VARY) 111111111 AT 1151 AND IliApr6" TRENCH WIDTH VARIES I I 1 PHOTOVOLTAIC ARRAY MOUNTED ROOF (R1) ON ALUMINUM RACK N SCALE: Cal C Driveway W s 1/16" = 1' E PLAN NI PROJECT LOG APPLICABLE CODES: ee e M 0SYSTEM°ETAILS SITSUNCOMMON SPRING SF ns TLEfamMODEL cmNOLoSe2�An-Ae 344 LAKE AVE . v« DATENOTA ns sysrEMsizF(k). ��e irvvESTEa f¢Tvt MosEL 44 E"'"ASEie7Aaz-z�s 1 13 HOOK ROAD SARATOGA SPRINGS,NY,T 2866 "° °°'..` °°"'°` CONTRACTOR TO PERFORM ERVICE s A miosswvEaTEas PV-02 •l RHINEBECK,NEW YORK 12572 CITY OF SARATOGA,INSIDE _ _ n+= ®= ALL WORK IN ACCORDANCE sSERVICE rvPE. UNDERGROUND unurv. NATIONAL GRID (866)-452-7652 PHONE:(ST 8)584-0596 GA COUNTY ( WITH THE 2020 RESIDENTIAL 2 ❑F 4 SUACOmmonCODE OF NEW YORK STATE. SUNCOMMON CONFIDENTIAL AND PROPRIETARY DocuSign Envelope ID'.06E958FE-DD16-472F-9C60-D1EAAD6A6S7E It is a violation of New Vac Stale Education Law RACKING DETAIL VIEW Article 145 far any person,unless acting under the direct supervision eta licensed professional engineer,to alter this drawing in any way. EOFN � ,S,,4FaRryA,. West Roof ( R3) ..r111 : NAPNRAGK MODULE CLAMP PITCH CHANGE 6'-1" �J MODULE RornaseNN 79�_C� - SNAPNRACK 11 SNAPNRACK ,-DocuSigned I, ULTRA RAIL UR SPEEDSEAL FOOT 0„ MODULE HEIGHT --IOFF ROOF,RANGE 11 � � 3-3/8"-4-3/8' Clamping Ranges for LG425GAK-A6 Modules — `COMP.SHINGLE ROOFING 10'A" (inches) // DECK NG 5" I 0-10' 25"MIN. SNAPNRACK _l EMBEDMENT LAG SCREW SS B-10' INTO WOOD MEMBER (5/16"DIAMETER) v FRAMING South Roof ( R1 ) East Roof ( R2) ROOF MOUNT DETAILS ARRAY SQUARE FOOTAGE 471 FT' 6"RIDGE CAP s° 22'4 B' 7 PITCH CHANGE 2'-2' 9'2' v-9' B„ TOTAL DISTRIBUTED LOAD 255 FOR 0-P MODULE DIMENSIONS(LENGTH X WIDTH X DEPTH). 75.2 X 41 02'01 50 5 ---- ROOF TYPE ASPHALT SHINGLE R ���� ROOF0140(INPITCH C). 1 23'(A1)//z5°(RO E R3) 10-8 RAFTER/TRUSS/SEAM SPACING(INCHES). 18'(R1)/24"(R2&R3) 15'2" III MAX ALLOWABLE ATTACHMENT SPACING(INCHES). 48" 6' MAX ALLOWABLE RAIL CANTILEVER(INCHES) pORDTRA TPE1 Bz(R1RR2R3 ) RAIL IVPE. SNAPNRACKUR40 1'-1' ATTACHMENT TYPE. SNAPNRACK SPEEDSEAL KIT 12.7' LS ARRAY LAYOUT PROJECT LOG APPLICABLE CODES: ne� M eeeeSYSTEMOET�MaeSUNCOMMON SPRING zE ur nLE eclon eocecMODEL e24Leez�AK-Ae 344 LAKE AVE oa V• m.E .mA AO SYSTEM SIZE(Mv(. �35e irvvESrEa(¢Tv1 MooEL D4 a"aHasEioaaaz-z�s fiN06 1 13 HOOK ROAD SARATOGA SPRINGS,NY,12866 "° °°'1_ °°_''°` CONTRACTOR TO PERFORM ERVICE e A mionowvEaTEas PV-03 °all RHINEBECK,NEW YORK 12572 CITY OF SARATOGA,INSIDE _ _ >_+_ ®= ALL WORK IN ACCORDANCE SSERVICE rveE. UNDERGROUND unurv. NATIONAL GRID (866)-452-7652 SARATOGA COUNTY WITH THE 2020 RESIDENTIAL 3 ❑P 4 SUACOmm�n PHONE:(518)584-0596 CODE OF NEW YORK STATE. SUNCOMMON CONFIDENTIAL AND PROPRIETARY t DocuSign Envelope ID'.06E958FE-DD16-472F-9C60-D1EAAD6A687E ELECTRICAL NOTES I. ALL CONDUCTORS SIZED o°E1811E/T10.s1E�,1E COFFER/AL. IFWOATED ON INTERIORT� CONDUCTOR. 6(mic S(EG31o'srecc3xac, rLOCATED ON INTERIOR ti ORTH BASEMENT WAL�i 310.1 5(e)(3)1)AND ARTICLE ego. LOCATED UNDER NORTH BASEMENT WAW D ACCORDING PV OUTPUT METER TO -_ .1TABLE R3 ARRAY ` 8O3016/31c.150 3) coPPE O/AL.1004240Vac NESGDNAN3 NEMA 0, CONDUCTOR. o(0o0A1 LOCATED AT:R2&R3' AG Landscape TOTAL BUN ( uDms PHASE "" MILBANK (Axi(A1000ID)(3)(a). GL 0)803)(0)AND CHAPTER 9. TO Li .'"uee3axL-BLG TABLE LE e. 1 7 n •• A�.O O O 0 • PERMANENT LABELS FOR THE )5 /Lsasa7asaa' C SYSTEM IN CORDING 3. INSTALLER SHALL PROVIDE • Wh • ELECTRICAL LABEL TO NEC BG,T.ARTICLE 690 AND • DRAWING.SEE 7x345Va—04425MAK-AB Modules=2875% TOTAL BUN 60' 00400100. 1 Circuit Of70443W r LOCATED UNDER , MC-1N4CABLE 4. ALL CONDUITS AND WIRE SIZES L R2 ARRAY • V - G.. SHOWN ARE MINIMUM REQUIRED SIZES. -- SITE CONDITIONS AND PROCUREMENT EN5H so cA e4L EMT 351"EMT MAY DICTATE LARGER SIZES BEING LOCATED AT:R2 B G ��a(P12) USED.WITH ENGINEERING APPROVAL. TOTAL BUN.36 SLIDEck ,GAN etc 5. ALL EXPOSED PV WIRE MUST BE 1 8 TOSOLOED,II GI e• GANP,G 0 0 0 • - -0-.4---0.--�• + _.--• ] s :AS OncLE 3co.SUPPORTED ACCORDING TO NECzG,7 6. ALL CONDUCTORS TO BE 10114011 of 8 LG4250AK-A6 Modules=3,400WpTOTAL BUN STRAND IS c' STRANDED TOOWN Lou UNLESS 8 x345Va=2,792W. LOCATED UNDER i MC-1N4 CABLE "" EATON UNGROUNDED CONDUCTOR INSULATION L R1 ARRAY 1 •• DG222URB o.BLUE,BROWN. O DENEM GA ORANGE.YELLOW LOCATED AT:01 oa(P1z SCI ELVA T TOTAL BUN • LOCATED ON EXTERIOR GROUNDED CONDUCTOR 1 7 TOsotnec ,a use EAST WALL INSULATION COLORS:WHITE.CHET, 0 O 0 O • Bucu+wwTE s-TRIPE. • 3 L B. 00AOE ENT 01/0EO AC DISCONNECT,NON-FUSIBLE coNcucToO corvoucTo0s0(c[c)Nc -- LG--O --0- - + • 60A 240Vac DING coLoOs:GREEN.GORE OCR.of 7 LG4250AK-A6 Motlules=2 WSWpTOTAL Al "NEUTRAL BONDED TO CABLGEC TO BE IRREVERSIBLY E 7x345Va=2443 Wac Mc-1004 cAAlF it LOCATED ON INTERIOR' GROUND" SPLICED OR EXOTHERMICALLY WELDED. LNDRTH BASEMENTWALU "RAPID SHUTDOWN INITIATION DEVICE PER NEC 600.12(C)' It is a violation or New York state Education Law IIT LOCATED ON EXTERIOR MAIN SERVICE PANEL ELECTRICAL SCOPE DETAILS Article 145 for any person,unless acting under the L EAST HOUSE WALL 200A,240Vac direct sapeMsion of a licensed professional "NEUTRAL BONDED TO GROUND" 3,01"EMT engineer,to alter this drawing in any way. UTILITY METER .oHa P6 200A,1207240 VAC SQUARE D HOMELINE c-•_)1 wn rveWro Zee, f,rB-1R S,qF use 2]024 0 1GAN a1c TO NATIONAL r ® n /-/----`-‘ GE UTILITY GRID -4 2000 F 4/0 ALSEU 4NALSEU //Q/Q Docubignad by: ELECTRICAL `� PROJECT Loc APPLICABLE CODES: SYSTEM DETAILS DRAWING ■■1 SUNCOMMON SPRING oa H. ICA DC SYSTEMSIZF�AT Peen MODULE(amMODEL Wz,LG4a�An-AG 344 LAKE AVE AO SYSTEM SIZE(M49. 3350 INVERTER(¢TT EXCEL 44 G"P"ASEIOTAaz-zA,s ,I 13 HOOK ROAD SARATOGA SPRINGS,NY,12866 "° 555 (55( CONTRACTOR TO PERFORM e A mloAowvEaTEas PV-04 :,l RHINEBECK,NEW YORK 12572 CITY OF SARATOGA,INSIDE _ _ >_+_ ®= ALL WORK IN ACCORDANCE SERVICESIZE TYPE0101: UNDERGROUND unuTv. NATIONAL GRID (866)-452-7652 PHONE:SARAT (GA COUNTY WITH THE 2020 RESIDENTIAL 4 ❑C 4 $uncommon (518)584-0596 CODE OF NEW YORK STATE. SUNCOMMON CONFIDENTIAL AND PROPRIETARY