HomeMy WebLinkAbout20240752 76 Walton Addition Final PlansScale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
0
0
P
M
A000
Cover Sheet
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
LEVEL 3 ALTERATION RENOVATION
AND 2-STORY ADDITION
AT
76 WALTON DR.
SARATOGA SPRINGS, NY 12866
BERGMAN RESIDENCE
Sheet
Number Sheet Name
Current Revision
Date
A000 Cover Sheet 8/11/24
A010 Site Plan & Code Schedule 8/11/24
A100 Basement Framing & Foundation Plan 8/11/24
A101 First Floor Framing & Proposed Plan 8/11/24
A102 Second Floor Framing & Proposed Plan 8/11/24
A103 Attic Framing & Proposed Plan 8/11/24
A104 Roof Removal, Framing and Proposed Plan 8/11/24
A200 Exterior Elevations 8/11/24
A300 Overall Building Sections Checker
A301 Building Sections at Addition 8/11/24
A302 Building Section and Details at Addition 8/11/24
A303 Sections at Stairs & Egress 8/11/24
A400 Reflected Ceiling Plans & Electrical Checker
A500 Exterior Wall Details
AD100 Demolition Plans & Notes Checker
AD101 Demolition Plans Checker
CS01 Alternative 2nd Floor Plan with Historic Elements Checker
SD200 Elevations 8/11/24
No. Description Date
Issued for Design Review Board 5/1/26
DN
WD
DN
SD
SD
SD SD
DN
DN
RE
F
.
SDSD
SD
SD
UP
W
REF.
DN
SD
SD
SD
DN
REF.
SD
SD SD
10' - 0"
NE
W
A
D
D
I
T
I
O
N
EX
I
S
T
I
N
G
T
O
R
E
M
A
I
N
EXISTING 2-STORY
GARAGE
EXISTING
SHED
EXISTING
CONCRETE PAD
EXISTING
PAVEMENT
EXISTING REAR YARD
EXISTING 2-
STORY
BUILDING
NEW 1-STORY ADDITION
WALTON STREET
RAILROAD ALLEY
NEW RETAINING WALLS
NEW PATIO
15' - 7 1/4"
RE-GRADE SOIL AT
GRADUAL SLOPE 1:2 MAX
6' - 9 1/4"
FENCE
147 SF
MECH/ LAUNDRY ROOM
20
171 SF
PASSAGE
21
226 SF
BEDROOM
23
210 SF
PLAYROOM
24
44 SF
BATHRM
22
321 SF
FAMILY ROOM
2515 SF
CL
25A
UNOCCUPIED SPACE
UNDER STAIR
47 SF
CL
23A
NEW EGRESS WINDOW
NEW EGRESS WINDOW WELL
PR
O
P
E
R
T
Y
L
I
N
E
2' - 8"
3' - 11"
3' - 0"
4'
-
6
"
170 SF
BEDROOM
16
153 SF
DINING
17
272 SF
KITCHEN
13
367 SF
LIVING
12
157 SF
BEDROOM
14
71 SF
ENTRY
10
R303.5.2 EXHAUST AIR
SHALL NOT BE DIRECTED
AT WALKWAYS
77 SF
BATHRM
10P
41 SF
HALL
10Q
7 SF
CL
10R
2ND DWELLING UNIT
PATH OF EGRESS
R705.5 NON LOAD-
BEARING WALL: FIRE
SEPARATION DISTANCE =
NON-RATED
EXISTING NONCONFORMING STAIRS
PERMITTED TO REMAIN IN
ACCORDANCE WITH THE EXISTING
BUILDING CODE, NO UNSAFE
CONDITIONS EXIST.
GUARDRAIL MIN. 3'-6" HT,
WITHSTAND LOAD OF 200 LBS
169 SF
LIVING
10S
248 SF
KITCHEN
10U
137 SF
PRIME BEDRM
10H
R420.3 FLOOR ASSEMBLY:
1 HR FIRE-RATED
DECK
1 HR FIRE-RATED
PARTITIONS AT FLOOR
OPENINGS, TYP.
HABITABLE SPACE WITH
7'-6" CH: 78 SF
MINIMUM ROOM AREA
REQUIRED: 70 SF
PROVIDED: 76 SF
142 SF
BEDROOM 3
32
165 SF
BEDROOM 2
33
11 SF
CL 4
33A
REQUIRED FLOOR AREA OF ROOM
ABOVE 5 FT HT: 135 SF
UNOCCUPIED
SPACE
UNOCCUPIED
SPACE
HABITABLE SPACE
WITH 7'-6" CH: 263 SF
FLOOR AREA ABOVE
5 FT HT: 340 SF
NOTE:EXISTING UNOCCUPIED
ATTIC CONVERTED INTO
OCCUPIED HABITABLE SPACE.
LEVEL TO BE SPRINKLERED BY
DELEGATED DESIGN..
R310 ATTIC SLEEPING ROOMS
SHALL BE PROVIDED WITH
EMERGENCY ESCAPE AND
RESCUE OPENINGS. OPENINGS
SHALL HAVE A MINIMUM NET
CLEAR OPENING OF 5.7 SQ FT,
MINIMUM CLEAR WIDTH OF 20 IN,
MINIMUM CLEAR HEIGHT OF 24 IN,
AND SILL HEIGHT NOT MORE THAN
44 IN ABOVE THE FLOOR.
2'
-
4
"
2' - 0" EGRESS WIDTH
42 SF
BATHRM
31156 SF
HALL
30
TYPICAL WALLS: EXISTING 2X4
FRAMING LIMITS CAVITY INSULATION
DEPTH. MAXIMUM FEASIBLE
INSULATION WITHIN EXISTING CAVITY
TABLE 302.1
EXTERIOR WALLS FIRE SEPARATION FROM PROPERTY LINE
WALLS
PROJECTIONS
OPENINGS
<5 FT
< 5 FT
<5 FT
0 HOUR FIRE-RATED MIN.
0 HOUR FIRE-RATED MIN.
UNLIMITED MAXIMUM OF WALL AREA: NON-
RATED
1. FIRE-RESISTANCE CONTINUITY
A. FIRE-RESISTANCE-RATED WALL ASSEMBLIES SHALL BE CONTINUOUS FROM
FOUNDATION TO UNDERSIDE OF ROOF SHEATHING, ROOF DECK, OR FLOOR/CEILING
ASSEMBLY ABOVE, AND EXTEND FULL LENGTH OF WALL, INCLUDING THROUGH
ATTACHED ACCESSORY STRUCTURES.
B. EXCEPTION: FIRE-RESISTANCE RATING AT UNDERSIDE OF EAVE OVERHANG PERMITTED
TO BE 0 HOURS WHERE APPROVED FIREBLOCKING IS INSTALLED FROM WALL TOP PLATE
TO UNDERSIDE OF ROOF SHEATHING.
2. EMERGENCY ESCAPE AND RESCUE OPENINGS
A. PROVIDE EMERGENCY ESCAPE AND RESCUE OPENINGS IN ACCORDANCE WITH CODE:
a. MINIMUM NET CLEAR OPENING: 5.7 SQ. FT.
b. GRADE FLOOR OPENINGS: 5.0 SQ. FT. MIN.
c. MINIMUM CLEAR HEIGHT: 24 INCHES
d. MINIMUM CLEAR WIDTH: 20 INCHES
3. SMOKE ALARMS
A. INSTALL SMOKE ALARMS IN ACCORDANCE WITH NFPA 72 AND APPLICABLE CODE
SECTIONS.
B. PROVIDE SMOKE ALARMS IN ALL DWELLING UNITS.
C. EXISTING DWELLINGS UNDERGOING ALTERATION, REPAIR, ADDITION, OR CHANGE OF
OCCUPANCY SHALL BE PROVIDED WITH SMOKE ALARMS PER APPENDIX J.
4. PROTECTION OF WOOD FROM DECAY
A. PROVIDE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD IN ACCORDANCE
WITH AWPA U1 AT THE FOLLOWING LOCATIONS:
a. WOOD JOISTS <18" TO GROUND; GIRDERS <12" TO GROUND IN CRAWL SPACES.
b. WOOD FRAMING ON FOUNDATION WALLS <8" FROM EXPOSED GROUND.
c. SILLS/SLEEPERS ON SLABS IN CONTACT WITH GROUND UNLESS SEPARATED BY
MOISTURE BARRIER.
d. ENDS OF GIRDERS EMBEDDED IN MASONRY/CONCRETE WITH <1/2" CLEARANCE.
e. EXTERIOR WOOD SIDING/SHEATHING/FRAMING <6" TO GRADE OR <2" TO PAVED
SURFACES.
f. WOOD SUPPORTING MOISTURE-PERMEABLE FLOORS/ROOFS EXPOSED TO WEATHER
WITHOUT MOISTURE BARRIER.
g. WOOD FURRING/FRAMING ON INTERIOR OF BELOW-GRADE MASONRY/CONCRETE
WALLS WITHOUT VAPOR RETARDER.
5. FIELD TREATMENT OF WOOD
A. FIELD-CUT ENDS, NOTCHES, AND DRILLED HOLES OF TREATED WOOD SHALL BE FIELD-
TREATED PER AWPA M4.
6. FASTENERS AND CONNECTORS
A. FASTENERS AND CONNECTORS IN CONTACT WITH PRESERVATIVE-TREATED OR FIRE-
RETARDANT-TREATED WOOD SHALL COMPLY WITH APPLICABLE STANDARDS.
B. PROVIDE HOT-DIPPED GALVANIZED, STAINLESS STEEL, SILICON BRONZE, OR COPPER
FASTENERS; STAPLES SHALL BE STAINLESS STEEL.
C. ZINC-COATED FASTENERS SHALL COMPLY WITH ASTM A153; STAINLESS STEEL
FASTENERS WITH ASTM F1667.
D. CONNECTORS: PROVIDE MINIMUM ASTM A653 G185 GALVANIZED WHERE
MANUFACTURER REQUIREMENTS ARE NOT SPECIFIED.
E. EXCEPTIONS:
a. 1/2" DIAMETER OR LARGER STEEL BOLTS.
b. MECHANICALLY DEPOSITED ZINC-COATED FASTENERS PER ASTM B695, CLASS 55
MINIMUM.
c. PLAIN CARBON STEEL FASTENERS PERMITTED IN SBX/DOT OR ZINC BORATE-TREATED
WOOD IN INTERIOR DRY CONDITIONS.
7. FIRE ALARM SYSTEM
A. PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH SECTION R314.7.
B. SYSTEM SHALL BE MONITORED BY AN APPROVED SUPERVISING STATION IN
ACCORDANCE WITH NFPA 72 THROUGHOUT THE BUILDING.
C. PROVIDE SYSTEM IN ACCORDANCE WITH APPENDIX J REQUIREMENTS WHERE
APPLICABLE.
8. HISTORIC BUILDING –FIRE AND LIFE SAFETY
A. COMPLY WITH FIRE AND LIFE SAFETY REQUIREMENTS FOR HISTORIC BUILDINGS.
B. PROVIDE HARD-WIRED, INTERCONNECTED SMOKE ALARMS THROUGHOUT.
C. PROVIDE CARBON MONOXIDE ALARMS THROUGHOUT DWELLING UNITS.
9. ALTERATIONS –LEVEL 2 COMPLIANCE
A. WORK CLASSIFIED AS LEVEL 2 ALTERATION SHALL COMPLY WITH NEW YORK STATE
EXISTING BUILDING CODE 2025.
B. NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY
WITH NEW YORK STATE BUILDING CODE 2025.
C. EXCEPTIONS:
a. NEWLY INSTALLED WINDOWS ARE NOT REQUIRED TO COMPLY WITH LIGHT AND
VENTILATION REQUIREMENTS.
b. NEWLY INSTALLED ELECTRICAL EQUIPMENT SHALL COMPLY WITH SECTION 807.
c. DEAD-END CORRIDORS IN NEW SPACES SHALL COMPLY WITH SECTION 805.6 ONLY.
d. MINIMUM CEILING HEIGHT FOR NEWLY CREATED HABITABLE/OCCUPIABLE SPACES
AND CORRIDORS: 7'-0" MIN.
10. CONSTRUCTION SAFETY –GENERAL
A. STORE AND PLACE CONSTRUCTION MATERIALS AND EQUIPMENT TO PREVENT HAZARD
TO PUBLIC, WORKERS, AND ADJACENT PROPERTY.
B. MAINTAIN REQUIRED EXITS, STRUCTURAL ELEMENTS, FIRE PROTECTION SYSTEMS, AND
SANITARY SAFEGUARDS AT ALL TIMES DURING CONSTRUCTION.
11. CONSTRUCTION SAFETY –WASTE REMOVAL
A. REMOVE WASTE MATERIALS IN A MANNER THAT PREVENTS INJURY OR DAMAGE TO
PERSONS, ADJACENT PROPERTY, AND PUBLIC RIGHTS-OF-WAY.
12. FIRE SAFETY DURING CONSTRUCTION
A. PROVIDE FIRE SAFETY MEASURES DURING CONSTRUCTION IN ACCORDANCE WITH:
a. NEW YORK STATE BUILDING CODE 2025
b. CHAPTER 33 OF THE NEW YORK STATE FIRE CODE 2025
13. FIREBLOCKING
A. PROVIDE FIREBLOCKING IN CONCEALED SPACES IN ACCORDANCE WITH R302.11.
B. COORDINATE WITH ALL PENETRATIONS, SOFFITS, AND CONCEALED FRAMING CAVITIES.
CONSTRUCTION TYPE: STACKED TWO-FAMILY DWELLING (NYSRC)
EXISTING:
CONVENTIONAL WOOD FRAMING WITH MASONRY VENEER EXTERIOR
WALLS
NEW ADDITION:
WOOD FRAMING WITH FIBER CEMENT BOARD SIDING
TYPE OF ALTERATION:LEVEL 3 -WORK AREA <50% BUILDING
TYPE OF WORK BEING PERFORMED:RENOVATION & ADDITION
SPRINKLERS:
REQUIRED AT THIRD STORY, AUTOMATIC
FLOOD HAZARD AREA:NO
METHOD OF COMPLIANCE:
ENERGY CODE: PRESCRIPTIVE
ASHRAE 90.1: PRESCRIPTIVE
EBC502.1 ALLOWABLE STORY, AREA & HEIGHT
3 STORIES ABOVE GRADE PLANE MAXIMUM
INCLUDES 1ST, 2ND, & ATTIC
BASEMENT <50% AREA BELOW GRADE
BASEMENT
FIRST FLOOR
SECOND FLOOR
ATTIC FLOOR
TOTAL:
EXISTING
1,120 SF
1,128 SF
1,128 SF
0 SF
3,376 SF
PROPOSED
403 SF
403 SF
-
515 SF
1,776 SF
SUBTOTAL
1,523 SF
1,531 SF
1,128 SF
515 SF
5,152 SF
ARCHITECTURAL GENERAL NOTES:
1. WRITTEN DIMENSIONS HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE
CONTRACTOR SHALL USE CAUTION WHEN SCALING REPRODUCED PLANS. IN THE
CASE OF A CONFLICT BETWEEN THIS PLAN SET AND ANY OTHER DRAWING, DETAIL,
OR SPECIFICATION THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR
CLARIFICATION.
2. ALL CONSTRUCTION IS TO COMPLY TO RESIDENTIAL CODE (2020) & LOCAL CODES.
NEW YORK STATE 2020 UNIFORM CODE SUPPLEMENT.
3. ALL DIMENSIONS FROM EXT. SHEATHING TO FINISHED DRYWALL
4. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
5. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE
CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED
MODIFICATIONS PRIOR TO COMMENCING INSTALLATION OF EQUIPMENT AND
ASSOCIATED WORK.
6. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR
OPENINGS.
7. ADJACENT AREAS AND/OR PORTIONS OF THE WORK AREA ARE OWNER OCCUPIED
AND OPERATE FULL TIMES TWENTY FOUR (24) HOURS A DAY AND SEVEN (7) DAYS A
WEEK. THE WORK SHALL BE COORDINATED TO ALLOW OWNER ACCESS ADJACENT TO
AND AROUND THE PROJECT SPECIFIC AREAS AT ALL TIMES UNLESS SPECIFICALLY
PERMITTED IN ADVANCE BY THE OWNER.
8. SPECIAL PROTECTION AND SEPARATION IS REQUIRED FOR WORK ADJACENT TO
OCCUPIED SPACES. AIR BARRIERS, AIR SEPARATION, AND OTHER PROTECTION
SHALL BE REQUIRED TO SEPARATE WORK FROM ALL OWNER OCCUPIED AREAS.
PROTECTION SHALL BE REQUIRED TO RESIST IMPACT BY OWNER TRAFFIC;
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING IMPACT REQUIREMENTS
WITH OWNER'S REPRESENTATIVE. ALL PROTECTION SHALL BE SUBJECT TO REVIEW
AND APPROVAL BY THE OWNER AND ARCHITECT.
9. SPECIAL NOISE CONTROL AND/OR LIMITED HOURS FOR WORK REQUIRING NOISE
AND/OR VIBRATION SHALL BE REQUIRED FOR WORK IN, ADJACENT TO AND ABOVE OR
BELOW OCCUPIED SPACES, INCLUDING BUT NOT LIMITED TO ANY WORK THAT MAY
TRANSMIT SOUND OR VIBRATION TO OWNER OCCUPIED SPACES. ALL SCHEDULING
FOR WORK PRODUCING NOISE SHALL BE SUBJECT TO APPROVAL BY THE OWNER.
10. PROVIDE 1/2 INCH GYPSUM WALL BOARD ON INTERIOR WALLS AND CEILINGS.
11. PROVIDE 1/2 INCH TYPE-X FIRERATED GYPSUM BOARD ON INSIDE OF FIRE-RATED
EXTERIOR WALLS.
12. PROVIDE 1/2 INCH WATER RESISTANT GYPSUM BOARD AROUND TUBS, SHOWERS AND
WHIRLPOOLS.
13. GRADE MUST DROP 6 INCHES THE FIRST 10 FEET OF GRADE FROM HOUSE
FOUNDATION
FIRE BLOCKING NOTES:
1. PROVIDE FIREBLOCKING AT ALL LOCATIONS REQUIRED BY CODE SECTION 602.8.
2. FIREBLOCK SECOND FLOOR JOISTS SO THAT NO HORIZONTAL RUN EXCEED 20'-0"
TYPICAL.
3. FIREBLOCK STAIRWELL ALONG STRINGERS.
4. FIREBLOCK WALLS WHERE THE VERTICAL CONCEALED SPACE EXCEEDS 8 FEET
VERTICALLY. VERTICAL CONCEALED SPACES ARE NOT TO EXCEED 8 FEET
VERTICALLY TYPICAL.
5. FIREBLOCK ALL WALLS WHERE A SOFFIT IS CONSTRUCTED AT THE SOFFIT LEVEL.
6. FIREBLOCK AT BEARING WALL AND GIRDER LOCATION.
R308 SAFETY GLAZING NOTES:
1. GLAZING REQUIRED IN SIDE-HINGED DOORS EXCEPT JALOUSIES.
2. GLAZING REQUIRED IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES
AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR ASSEMBLIES.
3. GLAZING REQUIRED IN STORM DOORS.
4. GLAZING REQUIRED IN ALL UNFRAMED SWINGING DOORS.
5. GLAZING REQUIRED IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS,
SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PART OF A
BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED
EDGE MEASURES VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.
6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE
THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARC OF THE DOOR IN A CLOSED
POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES OF THE GLAZING IS
LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE.
7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE
LOCATIONS DESCRIBED IN ITEMS 5 AND 6 ABOVE, THAT MEETS ALL OF THE
FOLLOWING CONDITIONS:
A. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET.
B. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
C. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR.
D. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE
GLAZING.
8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE A WALKING
SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL IN-
FILL PANELS.
9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR SWIMMING
POOLS, HOT TUBS, SHOWERS, BATHTUBS AND SPAS WHERE THE BOTTOM EDGE OF
THE POOL OR SPA SIDE IS LESS THAN 60 INCHES ABOVE A WALKING SURFACE AND
WITHIN 60 INCHES HORIZONTALLY OF THE WATER'S EDGE. THIS SHALL APPLY TO
SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING.
10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES
HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE
GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING
SURFACE.
11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES HORIZONTALLY OF THE
BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF
THE GLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THE TREAD.
WOOD PROTECTION NOTES:
1. PROTECTION OF WOOD AND WOOD-BASED PRODUCTS FROM DECAY SHALL BE
PROVIDED IN THE FOLLOWING LOCATIONS BY THE USE OF NATURALLY DURABLE
WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1.
A. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHERE
CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHERE CLOSER THAN 12
INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR
UNEXCAVATED AREA LOCATED WITHIN THE PERIPHERY OF THE BUILDING
FOUNDATION.
B. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR
FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203 MM) FROM THE
EXPOSED GROUND.
C. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT
CONTACT WITH THE GROUND UNLESS SEPARATED FROM SUCH SLAB BY AN
IMPERVIOUS MOISTURE BARRIER.
D. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE
WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH (12.7 MM) ON TOPS,SIDES
AND ENDS.
E. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A
BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152 MM) FROM THE
GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM
CONCRETE STEPS, PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL
SURFACES EXPOSED TO THE WEATHER.
F. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS
OR ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS CONCRETE OR
MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN
IMPERVIOUS MOISTURE BARRIER.
G. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED
DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY WALLS OR CONCRETE
WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS
APPLIED BETWEEN THE WALL AND THE FURRING STRIPS OR FRAMING MEMBERS.
MECHANICAL GENERAL NOTES:
1. ALL MATERIALS AND EQUIPMENT SUPPLIED SHALL BE INSTALLED AS PER
MANUFACTURERS SPECIFICATIONS AND AS PER LOCAL CODES AND
REQUIREMENTS.
2. FINAL LOCATION OF EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR AND
SUBCONTRACTORS.
3. ALL DUCT WORK IN SPACE SHALL BE SEALED WITH APPROVED TAPES OR
SEALANTS. SUPPLY DUCTS SHALL BE INSULATED TO R-8. ALL OTHER DUCTS TO
BE INSULATED TO R-6. DUCT TIGHTNESS SHALL BE VERIFIED BY A DUCT
PRESSURIZATION TEST.
4. HVAC CONTRACTOR TO VERIFY NEW FURNITURE LOCATIONS WITH OWNER.
5. ALL BATHROOMS SHALL BE PROVIDED WITH 3 SQUARE FEET OF GLAZED AREA,
HALF OF WHICH MUST BE OPENABLE UNLESS ARTIFICIAL LIGHT AND
INTERMITTENT MECHANICAL VENTILATION (50 CFM) TO OUTSIDE OR 20 CFM OF
CONTINUOUS VENTILATION IS PROVIDED.
6. THE MAXIMUM LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED
25 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. THE
MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET FOR EACH 45-
DEGREE BEND AND 5 FEET FOR EACH 90-DEGREE BEND. THE MAXIMUM LENGTH
OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT.
7. GAS CLOTHES DRYER EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED
WITH MAKEUP AIR. WHERE A CLOSET IS DESIGNED FOR THE INSTALLATION OF A
CLOTHES DRYER, AN OPENING HAVING AN AREA OF NOT LESS THAN 100 SQUARE
INCHES FOR MAKEUP AIR SHALL BE PROVIDED IN THE CLOSET ENCLOSURE.
8. CLOTHES WASHER DRAIN MUST BE 2 INCH DIAMETER AND CONNECT TO A 3 INCH
DIAMETER DRAIN MINIMUM.
9. APPLIANCE ACCESS -APPLIANCE SHALL BE ACCESSIBLE FOR INSPECTION.
SERVICE, REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT
CONSTRUCTION. THIRTY INCHES OF WORKING SPACE SHALL BE PROVIDED IN
FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE. APPLIANCE HAVING AN
IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE SOURCE OF IGNITION IS
NOT LESS THAN 18" ABOVE THE FLOOR IN GARAGES.
ELECTRICAL GENERAL NOTES:
1. ALL ELECTRICAL WORK IS TO COMPLY TO THE NATIONAL ELECTRICAL CODE.
2. ALL RECESS LIGHTS INSTALLED IN A THERMAL BARRIER SHALL BE RATED FOR
INSULATED CEILINGS (IC) AND BE OF THE AIR TIGHT TYPE WITH SEALING GASKET.
3. INSTALL 110V HARD-WIRED INTERCONNECTED SMOKE DETECTORS THRU-OUT THE
RESIDENCE PER CODE.
4. ELECTRICAL SERVICE SHALL CONTAIN AN EXTERIOR DISCONNECT WHERE THE
INTERIOR SERVICE ENTRANCE CONDUCTORS EXCEED 6 FT IN LENGTH.
5. SEE EQUIPMENT AND DEVICE MOUNTING HEIGHT DIAGRAM TO REFERENCE
DEVICE MOUNTING HEIGHTS, TYPICAL UNLESS OTHERWISE NOTED.
6. WHERE EXISTING OR SPECIAL CONDITIONS PREVENT THE INSTALLATION OF
DEVICES AT APPROPRIATE HEIGHTS, THE CONTRACTOR SHALL VERIFY HEIGHTS
WITH THE OWNER ON SITE.
7. PROVIDE CONTINUOUS BLOCKING CONCEALED WITHIN PARTITION AND WALL
CONSTRUCTION AS REQUIRED TO PROPERLY SECURE AND ANCHOR ANY AND ALL
WALL MOUNTED EQUIPMENT, FURNISHINGS, DEVICES, ETC.
8. WHERE SWITCHES, RECEPTACLES, THERMOSTATS, ETC. ARE INDICATED ON
WALLS IN PROXIMITY TO ONE ANOTHER, ALIGN VERTICALLY UNLESS NOTED
OTHERWISE.
9. WHERE SWITCHES, RECEPTACLES, THERMOSTATS, ETC. ARE LOCATED ADJACENT
TO DOOR FRAMES, LOCATE THE NEAR FACE OF THE DEVICE BOX 6" FROM FINISH
CASING OF DOOR FRAME, UNLESS OTHERWISE NOTED.
10. WHERE RECEPTACLES ARE SHOWN ADJACENT TO ROOM CORNERS, LOCATE
HORIZONTALLY 2'-0" FROM CORNER TO CENTER OF DEVICE BOX.
11. WHERE RECEPTACLES ARE SHOWN NEAR WALL CENTER, CENTER ON WALL.
12. COORDINATE LOCATIONS OF OUTLETS, FIXTURES, SWITCHES, SMOKE
DETECTORS, CARBON MONOXIDE DETECTORS, AND ALL OTHER DEVICES WITH
OWNER PRIOR TO INSTALLATION.
13. PROVIDE SMOKE DETECTORS:
A. AT EACH SLEEPING ROOM.
B. OUTSIDE EACH SEPARATE SLEEPING AREA.
C. ON EACH ADDITIONAL STORY OF THE DWELLING INCLUDING BASEMENT
14. R303.7 PROVIDE STAIRWAY ILLUMINATION WHERE ELECTRICAL POWER IS
PRESENT:
A. EACH INTERIOR STAIRWAY MUST BE PROVIDED WITH A MEANS OF
ILLUMINATION CAPABLE OF PROVIDING AT LEAST 1 FOOT-CANDLE OF
ILLUMINATION AT EACH LANDING OR AT AN INTERMEDIATE POINT BETWEEN
THE LANDINGS.
B. EXTERIOR STAIRWAYS MUST BE EQUIPPED WITH ARTIFICIAL ILLUMINATION AT
THE TOP LANDING.
C. EXTERIOR STAIRWAYS ACCESSING BASEMENTS SHALL BE EQUIPPED WITH
ARTIFICIAL ILLUMINATION AT THE BASE LANDING.
UTILITY GENERAL NOTES:
1. THE CONTRACTOR SHALL TAKE CARE TO NOT DAMAGE EXISTING UTILITIES. ANY
DAMAGED UTILITIES SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR AT
THE CONTRACTOR'S EXPENSE.
2. THE CONTRACTOR SHALL MAINTAIN FLOWS FOR ALL EXISTING UTILITIES.
3. ALL UTILITY LOCATIONS, EXISTING SEWERS, WATER, TELEPHONE, GAS ETC. MUST
BE LOCATED PRIOR TO ANY CONSTRUCTION. ELEVATIONS MUST BE VERIFIED
PRIOR TO CONSTRUCTION.
REMOVAL & DEMOLITION GENERAL NOTES:
1. PRIOR TO COMMENCING WORK THE CONTRACTOR SHALL VERIFY AND STAKE THE
LOCATIONS OF ALL UNDERGROUND UTILITIES. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO UTILIZE A LOCATING SERVICE TO VERIFY UNDERGROUND
UTILITY LOCATIONS.
2. CONTRACTOR SHALL VERIFY THE FOLLOWING: FIELD MEASUREMENTS, FIELD
CONSTRUCTION CRITERIA, CATALOGUE NUMBERS, AND SIMILAR DATA.
3. CONTRACTOR SHALL OBTAIN AND COMPLY WITH ALL NECESSARY APPROVALS,
PERMITS, INSPECTIONS AND CERTIFICATIONS PRIOR TO AND DURING THE
COURSE OF CONSTRUCTION.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR OR REPLACE ALL ITEMS DAMAGED
OUTSIDE OF CONSTRUCTION LIMITS, OR ANY ITEMS DISTURBED ON THE SITE
WHICH ARE NOT PART OF THE IDENTIFIED WORK OF THIS CONTRACT.
5. CONTRACTOR SHALL PROVIDE PROPER SIGNS, BARRICADES, FENCES, TO
PROTECT THE WORK, PROPERTY, EQUIPMENT AND PERSONS FROM DAMAGE
DURING ALL PHASES OF CONSTRUCTION.
6. DO NOT DRIVE VEHICLES, STORE EQUIPMENT, SPILL LIQUIDS OR STORE
CHEMICALS ON THE SITE. CONTRACTOR IS RESPONSIBLE FOR DAMAGE OUTSIDE
THE CONSTRUCTION LIMIT LINE AND WITHIN PROTECTION AREAS.
7. CONTRACTOR SHALL STRIP, STORE, AND REUSE ALL TOPSOIL FROM AREAS TO BE
PAVED OR RE-GRADED. PROVIDE SEDIMENT CONTROL FENCE AROUND BASE OF
TOPSOIL STOCKPILE.
8. IN AREAS WHERE PLANT MATERIAL IS PROPOSED ON AREAS OF EXISTING
PAVEMENT, EXCAVATE EXISTING SOIL TO A DEPTH OF 30" AND REPLACE WITH
APPROVED TOPSOIL, COORDINATE WITH PLANTING PLAN.
9. ALL EXISTING MATERIAL TO BE SALVAGED SHALL BE VERIFIED BY THE OWNER'S
REPRESENTATIVE AND REMOVED AND STORED BY CONTRACTOR IN A LOCATION
COORDINATED WITH OWNER. CONTRACTOR SHALL COMPENSATE OWNER FOR
ANY DAMAGE TO SALVAGED MATERIALS THAT OCCURS DURING REMOVAL,
STORAGE OR REINSTALLATION.
10. ALL EXISTING UTILITIES TO REMAIN, UNLESS OTHERWISE NOTED.
11. WHEN PRACTICAL ALL SAW-CUTS INTO EXISTING CONCRETE SHALL OCCUR AT
EXISTING CONSTRUCTION OR EXPANSION JOINTS.
12. REMOVE CONSTRUCTION AS REQUIRED FOR PROPER INSTALLATION OF NEW
OPENING AND TO PROPERLY RECEIVE NEW CONSTRUCTION.
13. REMOVE WALL MOUNTED ELECTRICAL RACEWAY, DEVICES, CABLING AND
MOUNTING AND ANCHORAGES COMPLETE. CLEAN, PATCH AND REPAIR REMAINING
WALL SURFACES AS REQUIRED TO PROVIDE A SMOOTH SURFACE READY TO
RECEIVE PAINT.
14. COORDINATE EXACT EXTENT OF ALL REMOVALS AND MODIFICATIONS WITH
REQUIREMENTS OF NEW CONSTRUCTION. DIMENSIONED REMOVALS ARE FOR
GENERAL INFORMATION PURPOSES ONLY. REFER TO PLANS AND DETAILS FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
15. ALL REMAINING WALL, FLOOR, CEILING AND ANY AND ALL OTHER EXISTING
CONSTRUCTION DAMAGED DURING REMOVALS ARE TO BE REPAIRED SUCH THAT
REMAINING SURFACES ARE SMOOTH AND FLUSH WITH SURROUNDING MATERIALS
AND READY FOR APPLICATION OF REQUIRED FINISHES. PROVIDE NEW MATERIALS
TO MATCH EXISTING ADJACENT MATERIALS AND FINISHES AS REQUIRED TO
MATCH EXISTING CONSTRUCTION.
16. REMOVE ALL DISCONTINUED OR NON-FUNCTIONING WIRE, TELEPHONE AND DATA
COMMUNICATIONS CABLING COMPLETE.
17. CONTRACTOR IS RESPONSIBLE TO MEET ALL OSHA REGULATIONS AND BUILDING
CODE REQUIREMENTS FOR THE REMOVAL OF EXISTING BUILDINGS AND
SELECTIVE DEMOLITION OF BUILDING COMPONENTS.
CODE NOTES GENERAL NOTES
GROSS BUILDING AREACODE CLASSIFICATIONS
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
0
2
P
M
As indicated
A010
Site Plan & Code Schedule
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/8" = 1'-0"1 Site Plan
Garage Doors No less than 0.40 ECCNYS Table R402.5.2
Swinging Doors No less than 0.50 ECCNYS Table R402.5.2
Sliding Doors No less than 0.30 ECCNYS Table R402.5.2
Windows No less than 0.30 ECCNYS Table R402.5.2
Air Barrier No less than 0.004 ECCNYS R402.5.1.2.1
Air Leakage - Thermal Envelope Air Permeability - cfm/ft2
PF > or equal 0.5 0.61 ECCNYS Table R402.1.4
0.2 < or equal PF < 0.5 0.46 ECCNYS Table R402.1.4
SHGC - PF < 0.2 0.38 0.35 ECCNYS Table R402.1.4
Glazed Fenestration SHGC ECCNYS Table R402.1.4
Fenestration U-Factor
Fixed
Operable
Entrance Doors
U-0.27
U-0.45
U-0.77
U-0.55
ECCNYS Table R402.1.4
Fenestration Requirements
Access doors Same as Wall R-Value Y ECCNYS R402.2.4
Attic Knee Wall Same as Wall R-Value Y ECCNYS RTable R402.1.3 and R402.2
Unheated Slab R-Value & Depth R-10ci & 4 ft R-10ci ECCNYS Table R402.1.3
Below Grade Wall R-15ci or R-13 cavity +
R-5ci
R-13+R-5ci ECCNYS Table R402.1.3
Mass Wall R-20ci at Interior side R-20ci at Interior side ECCNYS Table R402.1.3
Wood Frame Wall R-30 or R-20+R-5Ci R-30 ECCNYS Table R402.1.3
Ceiling R-Value (Without Attics) R-49 R-49 ECCNYS Table R402.1.3
Opaque Thermal Envelope Requirements
C4 Commercial Energy Efficiency Required Provided Reference
Degree Days 6,894 HDD65 Zone 14A
Climate Zone Saratoga County 5A ECCNYS Table R301.1
C3 General Requirements Reference
2025 Energy Conservation Code of New York State ECCNYS
2025 Existing Building Code of New York State EBCNYS
2025 Residential Code of New York State RCNYS
Applicable Codes
Energy Code Information Reference
1/8" = 1'-0"2 Basement Life Safety Plan
1/8" = 1'-0"3 First Floor Life Safety Plan
1/8" = 1'-0"4 Second Floor Life Safety Plan
1/8" = 1'-0"5 Attic Life Safety Plan
No. Description Date
UP
WD
DN
TOP OF SLAB AT -6 1/2" BELOW EXISTING
BASEMENT FLOOR ELEVATION
PROVIDE CONTINUOUS TOP & BTM RUBBER WATER
STOP. CONNECT NEW CONC. WALL TO EXTG, PRE-DRILL
4" DEEP HOLES INTO EXTG WALL 12" OC. ENTIRE HEIGHT
OF WALL, SET 8" LONG #4 REBAR INTO THE PRE-DRILLED
HOLE WITH EPOXY. POUR NEW WALL OVER EXPOSED 4"
OF REBAR (TYP.)
8" CONC. FOUNDATION WALLS, #4
VERTICAL REBAR AT 4'-0" OC., 6" INTO
FOOTING UP TO FIRST FLOOR LEVEL
FOOTING
1' - 4"
WALL
8".
T/O CURB FLUSH WITH FLOOR SLAB
TOP OF RETAINING
WALL AT GRADE
DEPRESSION FOR 6" X 6" TRENCH DRAIN
5' - 7 1/4"6' - 9 1/4"8"19' - 6 1/4"8"2' - 10"
+ 5' - 6"
T/O WALL ABV BASEMENT
SLAB LEVEL, VIF.
1'
-
0
"
SAW CUT NEW OPENING IN EXIST.
FDN WALL 7'-0" HIGH
EXTG F.J. TO REMAIN
TYPICAL AT TOP OF FOUNDATION WALL:
TREATED 2X12 LEDGER
STAGGER BOLTED HI-LOW
W/1/2"Ø GALVANIZED EXPANSION
BOLTS & WASHERS AT 12" O.C. &
MAX OF 2" FOR EA. END OF
LEDGER FOR NEW JOIST
HANGERS WRAPPED W/Z-FLASHING
EXTG F.J. TO REMAIN
EXISTING WINDOW
OPENINGS TO REMAIN
TOP OF EXTG SLAB AT 0" -0"TOP OF EXTG SLAB AT -0" -4"
TOP OF NEW SLAB AT
BELOW EXTG BASEMENT LEVEL
6"
1'
-
5
"
9"
SL
O
P
E
1
/
4
"
PE
R
1
2
"
M
I
N
.
-1' - 11 1/2"
T/O FOOTING
CONCRETE IN PLACE WITH 20" X 12" 3
#4 REBAR
FOUNDATION FLOOR
4" CONC. WITH 6X6 W2.9 W.W.F. ON 6 MM
POLYETHYLENE VAPOR BARRIER ON R-10
POLYISOCYANURATE RIGID INSULATION ON
4" COMPACTED GRAVEL BASE
PATIO AT GRADE
STONE SET IN 4" CONC. SLAB ON 4" GRAVEL.
TOP OF NEW SLAB AT -0 -7" EL. BELOW T.O.S.
ADDITION LEVEL
8 1/2"
REMOVE AND CUT STONE
FOUNDATION WALL OPENING TO
FIT NEW EGRESS WINDOW,
REUSE EXIST. WDW HDR
4'
-
6
"
3' - 0"
3' - 9"
4
1
/
4
"
4'
-
1
0
3
/
4
"
9'
-
1
1
1
/
4
"
16
'
-
1
0
1
/
2
"
10
'
-
1
1
3
/
4
"
0"
11' - 8 1/2"
1' - 4" FTG
2" STONE VENEER
AT EXPOSED SIDE
4" DIA WEEP HOLES AT CENTER OF
WALL LENGTH, 1 FT HT ABOVE PATIO
SLAB, TYP. AT RETAINING WALLS
4X4 PRT WD POST COLUMN
ANCHORED TO 3 FT DIA.
CONCRETE PIER
FOUNDATION, MIN 4 FT
BELOW GRADE
-11 1/2"
2'
-
6
"
1'
-
5
"
1
A301
1
A302
1
A302
W6
W6
W6
11
1
/
4
"
4'
-
7
3
/
4
"
7'
-
8
"
D3
6
S60
D32
D3
6
X7
2
MECH/ LAUNDRY ROOM
20
PASSAGE
21
BEDROOM
23
PLAYROOM
24
FAMILY ROOM
25
BATHRM
22
ALIGN WALLS BELOW
WITH FACE OF STAIR
CARRIAGE LANDING
ABOVE
ALIGN
-11 1/2" T/O CONC. SLAB
-11 3/4" T/O FF
FACE OF FOUNDATION WALL
CONC. RETAINING WALL BY DELEGATED DESIGN
BLUESTONE PATIO STONE FLOOR
6X6 TRENCH DRAIN
CONNECTED TO
UNDERGROUND
PERFORATED DRAIN AT
FOOTINGS
NOTE:
1. EXPOSED BRICK WALL AT EXISTING LOCATIONS.
PATCH AND REPAIR GROUT IN EXPOSED
LOCATIONS. APPLY CLEAR SEALER TO PROTECT
SURFACES.
2. FOR INTERIOR FINISHES, CABINETRY, FIXTURE
SELECTIONS AND TRIMWORK, REFER TO
INTERIOR DWGS.
4
A303
B60
ELEC RM
10Z
36C
2
A301
12" X 12"
ACCESS
PANEL, TYP.
METAL
LADDER TO
GRADE
WIN
D
O
W
4'
-
6
"
O
.
C
.
8" IN SITU CONCRETE RETAINING WALL
3
A303
3' - 0"
W4
TYP. UON
RE-CONSTRUCT
CONCRETE EDGE OF
SLAB AT DIFF. BELOW
1-
P
L
Y
1
3
/
4
"
X
9
1
/
4
"
L
V
L
5'
-
4
"
6X6 POST COLUMNS, TYP.
D3
6
CL
25A
3' - 11 3/4"
3-PLY 1 3/4" X 11 1/4" LVL
11' - 4 3/4"
12' - 6" W10X33 ABV
ET
R
W
N
D
W
H
D
R
3'
-
3
"
F4
F4T
INFILL WALL AT
OPENING
(3) 2X10 WD HDR
6' - 9"
FRAMING PLAN NOTES
FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS
PRIOR TO COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER,
STUDS -STUD GRADE, U.O.N.
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL
DEPTH SOLID BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT
TO HEADER, BAND, RIM JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED
AT EACH INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054
THICK BY 1 1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR
WALLS ARE COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY
STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8.,
602.6(1).(2) R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS
ARE COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN
PREPARED UNDER THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE
CERTIFIED PROFESSIONAL STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED
ENGINEERING PRACTICE (ASCE-7), CROSS-LAMINATED TIMBER TO BE MANUFACTURED AND
IDENTIFIED ACCORDING TO ANSI/APA PRG 320.
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR
BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE
EXTERIOR OF THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
16. ALL PENETRATIONS IN FIRE RATED PARTITIONS TO BE FIRE STOPPED AND SEALED.
17. ALL FIRE AND SMOKE RESISTANCE RATED WALL ASSEMBLIES SHALL BE IDENTIFIED AND
MAINTAIN REQUIRED CONTINUITY.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
TYPE ID
S4
W4a
W4
W4i
F4
F4T
W6
PARTITION ASSEMBLY
1-HOUR SHAFT WALL (UL U305) 1" TYPE X SHAFT LINER ON 4"
H-STUD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1-HOUR FIRE-RATED WALL (UL U305) 5/8" TYPE X GYP BD ON
2X4 WD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2" GYP BD, TYPICAL
U.O.N.
SAME AS W4, WITH CLOSED CELL SPRAY FOAM INSULATION
(MIN. R-20)
1/2" GYP BD ON 2X4 WD FURRING
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2" GYP BD
WALLS WITH THIS SYMBOL INDICATE 3" SOUND-ABSORBING
INSULATION IS ADDED FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND
ATTIC FLOOR
DECK
ROOF (PITCHED)
SNOW
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
30 PSF
100 PSF
20 PSF DEAD
50 PSF GROUND SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
INDICATES POINT LOAD SUPPORTED BELOW
INDICATES POINT LOAD FROM ABOVE
NEW WALL
NEW DOOR
1. ALL CONC. TO BE MIN. 3000 PSI AT 28 DAY COMPRESSIVE STRENGTH.
2. ALL CONC. TO REST ON UNDISTURBED SOIL OF 2000 PSF BEARING CAPACITY
MINIMUM, OR COMPACTED STRUCTURAL FILL OR BEDROCK.
3. CONC. FOOTINGS TO BE LOCATED MIN. -4'-0" FROM GRADE TO TOP OF
FOOTING U.O.N. FOOTINGS MAY BE STEPPED DOWN OR LOWERED TO REACH
AN ACCEPTABLE BEARING STRATUM AS DETERMINED BY GEOTECHNICAL
ENGINEER.
4. DO NOT PLACE FOOTINGS IN WATER OR IN FROZEN GROUND.
5. DO NOT ALLOW GROUND BENEATH FOOTINGS OR SLABS TO FREEZE.
6. CENTER FOOTINGS UNDER WALLS OR GRADE BEAMS U.O.N.
7. WHERE CONTROL JOINTS ARE NOT INDICATED ON PLAN, PROVIDE CONTROL
JOINTS SPACED AT 35 FEET, MAXIMUM.
8. CONCRETE WALLS SHALL ATTAIN A MAXIMUM STRENGTH OF 70% F'C BEFORE
PLACING BACKFILL AGAINST THEM.
9. EXTEND WALL FOOTING REINFORCEMENT INTO COLUMN FOOTINGS WITH A
MINIMUM EMBEDMENT EQUAL TO THE MINIMUM BAR DEVELOPMENT LENGTH.
10. CAST STEPPED FOOTINGS MONOLITHICALLY.
11. DO NOT LOCATE PENETRATIONS THROUGH FOOTINGS. STEP FOOTINGS
DOWN AS REQUIRED TO LOCATE PENETRATION IN WALL.
12. CHAMFER EXPOSED CONCRETE CORNERS AND EDGES 3/4 INCH U.O.N.
13. CONCRETE COVER FOR REINFORCEMENT SHALL BE 1 1/2" MIN.
FOUNDATION PLAN NOTES
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
0
2
P
M
As indicated
A100
Basement Framing & Foundation Plan
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"2 Basement Foundation Plan
1/4" = 1'-0"3 Basement Framing Plan
No. Description Date
DN
DN 15
14
13 12 11 10 9 8 7 6 5 4 3 2 1
DN
RE
F
.
1
A301
2
A303
1
A302
1
A302
5'
-
0
"
7'
-
0
3
/
4
"
(3) WD FRAMING STUDS
5' - 10"27' - 3" NEW ADDITION 2' - 11 3/4"
NEW 2X10 AT 16" O.C. WD FRAME FLOOR
INFILL FLUSH WITH EXTG ADJACENT WD
FRAMING
15
'
-
1
1
3
/
4
"
5' - 10"
SP
S
S
2
X
1
0
AT
1
2
"
O
.
C
.
17' - 7" W10X33 ABV
DBL. 2X10 HEADERS AT ALL
NEW DOOR AND WINDOW
OPENINGS, TYP.
INFILL WD FRAMING AT EXTG
OPENINGS TO MATCH EXISTING TYPE
& ALIGN WITH ADJ, TYP.
EXTG 2X8 TO
REMAIN
EX
T
G
2
X
8
T
O
RE
M
A
I
N
EX
T
G
2
X
8
T
O
RE
M
A
I
N
PATCH AND REPAIR EXTG
OPENING, INFILL WALL WITH
SALVAGED BRICK, TYP.
4' - 6 1/2"4' - 6 1/2"4' - 6 1/2"4' - 6 1/2"4' - 6 1/2"4' - 6 1/4"
36A36A
36A
LANDING
4' - 0 3/4"
(10) T AT 11" D EA.
11' - 0"
11
"
NEW WALL PENETRATION
FOR NEW HOOD EXHAUST
EXISTING STAIR TREAD AND
STRINGERS TO REMAIN
NEW WD RAILING, TOP OF
HANDRAIL AT 34" HT ABOVE
TREAD, TYP.
NEW PTD. WALL UNDER STAIR
EXISTING LOAD-BEARING WALL
TO REMAIN
BEDROOM
16
DINING
17
LIVING
12
BEDROOM
14
ENTRY
10
5'
-
0
1
/
4
"
10
'
-
1
1
1
/
2
"
1
A300
1
A300
4
A303
KITCHEN
13
16
'
-
9
"
N
E
W
A
D
D
I
T
I
O
N
36A36A36A
(2) T AT 11" D EA.
SECURE NEW WD
FRAMING THROUGH
BRICK WITH BOLTS TO
EXTG WD FRAMING, TYP.
2' - 3 1/2"
1' - 7"3' - 2"2' - 6"
# TREADS VIF. TO GRADE
5' - 6"
LANDING
4' - 0"
2'
-
2
"
3'
-
0
"
4"
2
A301
4X4 WD POST COLUMN SET IN
CONCRETE PIER FOOTING TO
3'-0" BELOW GRADE
(2) 2X10 PRTD WD
DROP BEAM
EX
T
G
2
X
8
T
O
RE
M
A
I
N
EX
T
G
2
X
8
T
O
RE
M
A
I
N
3'
-
1
1
/
2
"
1'
-
5
1
/
2
"
3' - 11"11' - 5"
6' - 5"
EXTG 2X8 TO
REMAIN
3'
-
0
"
4"
5'
-
6
"
PRTD 2X10 WD
AT 16" O.C.
3-
P
L
Y
1
3
/
4
"
X
1
4
"
L
V
L
10
'
-
3
"
AB
V
1
3
/
4
"
X
9
1
/
2
"
L
V
L
3'
-
7
"
STL BEAM MIN. BEARING 3" ON
REINF. (3) WD FRAMING STUDS
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
W4
TYP. UON.INFILL WALL TO MATCH ADJ.
INFILL WALL TO MATCH ADJ.
DRAIN
FROM ABV
W6
2
A300
2
A300
2-PLY 1 3/4" X 14" LVL HDR
7' - 9"
STL LINTEL L5X3-1/2X1/2 AT BRICK ETR
TYP.
HANDRAIL
POST
PROVIDE (3) 2X8 WD FRAMING
CROSS-SUPPORT BTW F.J. AT
LOCATIONS OF POINT LOADS
ABOVE, TYP.
1 HR FIRE-RATED SHAFT
CONSTRUCTION FOR
MECHANICAL SYSTEMS
WOOD HANDRAIL AT 3-0 HT.,
METAL 34 DIA. BALUSTERS
SPACED AT 4" MAX. O.C.
NOTE:
1. EXPOSED BRICK WALL AT EXISTING LOCATIONS.
PATCH AND REPAIR GROUT IN EXPOSED
LOCATIONS. APPLY CLEAR SEALER TO PROTECT
SURFACES.
2. SP SS : SOUTHERN PINE GRADE SS
TYP. 1ST FLOOR ASSEMBLY:
• NEW FINISH FLOORING
• NEW SUBFLOORING: 1/2" OSB PLY.
• EXIST. 2X8 WD FRAMING
• NEW SAB BATT INSULATION
• (1) LAYER PTD. GWB
D3
6
D3
0
D3
0
X36
D28
D30
9' - 6"
6'
-
1
"
FRAMING PLAN NOTES
FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS
PRIOR TO COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER,
STUDS -STUD GRADE, U.O.N.
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL
DEPTH SOLID BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT
TO HEADER, BAND, RIM JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED
AT EACH INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054
THICK BY 1 1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR
WALLS ARE COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY
STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8.,
602.6(1).(2) R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS
ARE COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN
PREPARED UNDER THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE
CERTIFIED PROFESSIONAL STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED
ENGINEERING PRACTICE (ASCE-7), CROSS-LAMINATED TIMBER TO BE MANUFACTURED AND
IDENTIFIED ACCORDING TO ANSI/APA PRG 320.
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR
BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE
EXTERIOR OF THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
16. ALL PENETRATIONS IN FIRE RATED PARTITIONS TO BE FIRE STOPPED AND SEALED.
17. ALL FIRE AND SMOKE RESISTANCE RATED WALL ASSEMBLIES SHALL BE IDENTIFIED AND
MAINTAIN REQUIRED CONTINUITY.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
TYPE ID
S4
W4a
W4
W4i
F4
F4T
W6
PARTITION ASSEMBLY
1-HOUR SHAFT WALL (UL U305) 1" TYPE X SHAFT LINER ON 4"
H-STUD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1-HOUR FIRE-RATED WALL (UL U305) 5/8" TYPE X GYP BD ON
2X4 WD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2" GYP BD, TYPICAL
U.O.N.
SAME AS W4, WITH CLOSED CELL SPRAY FOAM INSULATION
(MIN. R-20)
1/2" GYP BD ON 2X4 WD FURRING
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2" GYP BD
WALLS WITH THIS SYMBOL INDICATE 3" SOUND-ABSORBING
INSULATION IS ADDED FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND
ATTIC FLOOR
DECK
ROOF (PITCHED)
SNOW
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
30 PSF
100 PSF
20 PSF DEAD
50 PSF GROUND SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
INDICATES POINT LOAD SUPPORTED BELOW
INDICATES POINT LOAD FROM ABOVE
NEW WALL
NEW DOOR
PLAN VIEW
FLOOR SECTION
HEAD SECTION BOTTOM OF STRUC
ACOUSTICAL OR FIRE RESISTIVE
JOINT SEALANT (BOTH SIDES)
SCHED. CEILING, SEE RCP
5/8" TYPE X GWB EA. SIDE FULL HEIGHT
WOOD STUDS AT 16" O.C., FRT WOOD
STUDS AT 1HR FIRE-RATED WALLS
SOUND ATTENUATION BATT INSULATION
(TO UNDERSIDE OF DECK) WHERE
INDICATED ON PLANS
ACOUSTICAL OR FIRE RESISTIVE
JOINT SEALANT (BOTH SIDES)
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
0
3
P
M
As indicated
A101
First Floor Framing & Proposed Plan
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"2 First Floor Framing
Door & Window Schedule
Door # Quantity Width Height Door Type Glass Type Daylight Area
Heat Transfer
Coefficient (U)Thermal Resistance (R) Fire Rating Comments
X72 1 6' - 0" 6' - 8" Exterior Double Panel
X36 2 3' - 0" 7' - 8" Exterior Single Panel See Product
Documentation Link for
more information
B42 6 3' - 6" 6' - 8" Interior BiFold -
B60 1 5' - 0" 6' - 8" Interior BiFold -
B48 1 4' - 0" 7' - 0" Interior Bifold -
D28 2 2' - 4" 7' - 0" Interior Single Panel
D30 8 2' - 6" 6' - 8" Interior Single Panel -
D32 3 2' - 8" 6' - 8" Interior Single Panel -
D32A 1 2' - 8" 7' - 0" Interior Single Panel 45-MIN CLOSER
D36 4 3' - 0" 6' - 8" Interior Single Panel -
S60 1 5' - 0" 6' - 8" Interior Sliding 2-Panel -
A30 1 2' - 6" 4' - 0" Interior Storage Access - R-30 MIN INSULATED
Window # Count Width Height Head Height Manufacturer Model Daylight Area Vent Area
Heat Transfer
Coefficient
U-Factor
Thermal
Resistance
R-value
Solar Heat Gain
Transmittance
Visible Light
Transmittance Comments
24K 1 2' - 0" 2' - 6" 4' - 6"
31 1 2' - 7" 5' - 10" 7' - 10" Pella Dual Pane Vent 15 SF 14 SF 0.4 2.5 0.4 0.81
36A 6 3' - 0" 5' - 0" 7' - 8" Pella Dual Pane Vent 15 SF 14 SF 0.4 2.5 0.4 0.81
36C 2 2' - 6" 3' - 0" <varies> Pella Casement 0 SF 25 SF 0.4 2.5 0.4 0.81
39K 1 4' - 0" 3' - 6" 6' - 6"
No. Description Date
1" = 1'-0"1 PARTITION TYPE W - 1HR FR
DN
UP
W
REF.
DNUP
W
REF.
14' - 1"10' - 0"3' - 11"3' - 1"
4x4 WD COLUMN TO SUPPORT
ATTIC STRUC FL AND STAIR
FRAMING ABOVE, TYP.
NE
W
2
X
1
0
A
T
1
6
"
O
.
C
.
NEW STL LINTEL TO SUPPORT
BRICK WALL ABOVE, SECURE TO
2ND FLOOR JOIST FRAMING
BELOW, SPAN OPENING BELOW
NEW STAIR; CLOSED
STRINGER SECURED TO
EXTG WD WALL ADJ,
PROVIDE ADDITIONAL WD
BLOCKING
EQ
EQ
EQ EQ
20' - 5 1/2"
7'
-
2
"
2' - 2"
9'
-
2
"
6' - 9"8' - 4"
3'
-
6
"
4'
-
4
"
5'
-
1
1
"
W6
ALIGN
3' -6" H 1 1/2" DIA. GUARDRAIL,
TENSION CABLE (SPACED 4" MAX.
O.C.), 1 1/2" DIA. POSTS SECURED
WITH GALV. STL ANGLES TO ROOF
JOISTS STRUC FRAMING BELOW
INFILL GWB ON WD
FRAMING TO MATCH
ADJACENT WALLS
10
'
-
1
0
1
/
4
"
5' - 8"27' - 6 1/2"2' - 10 1/4"
ROOF TYPE 3 (DECK ON TPO ROOF)
1x4 TREX DECKING ON PRESSURE-TRD WD
SLEEPERS ON TPO MEMBRANE FULLY
ADHERED WITH HEAT-WELDED SEAMS ON
5/8" THK COVER BOARD ON R-10 (MIN. 2")
RIGID INSULATION ON 3/4" THK EXTERIOR
GRADE PLY SHEATHING ON 2X10 WD
FRAMING AT 16" O.C. WITH R-19 FACED BATT
INSULATION
EX
I
S
T
.
2
X
1
0
A
T
1
6
"
O
.
C
.
EXIST. 2X10 AT 16" O.C.
EXIST. 2X10 AT 16" O.C.
INFILL FLOOR WITH
NEW FRAMING TO
MATCH EXIST.
DBL. 2X10 HEADERS AT
ALL NEW DOOR AND
WINDOW OPENINGS, TYP.
3' - 5"
TYP. UON
NEW DOOR OPENING IN
EXTG WINDOW OPENING
EXIST. 2X10 AT 16" O.C.
VENT ABOVE TO ROOF
4'
-
7
"
4'
-
1
0
"
12
'
-
5
"
3'
-
0
"
2-
P
L
Y
1
3
/
4
"
X
9
1
/
2
"
L
V
L
H
D
R
6'
-
3
"
PROVIDE FIRESTOPPING AT CONDUIT/
PIPEWORK PENETRATING FLORO
BELOW, TYP. AT ALL LOCATIONS
CONTINUOUS 1-HOUR FIRE-RATED
SEPARATION REQUIRED AT SECOND FLR
FLOOR ASSEMBLY, AND STAIR
ENCLOSURE.
W4
a
S4
NEW CLOSED CELL SPRAY INSULATION
(MIN R-30) AT EXISTING EXTERIOR
WALL BRICK ON 2X6 WD FRAMING TO
REMAIN, TYP.
1
A301
2
A303
NOTE:
1. EXPOSED BRICK WALL AT EXISTING LOCATIONS.
PATCH AND REPAIR GROUT IN EXPOSED
LOCATIONS. APPLY CLEAR SEALER TO PROTECT
SURFACES.
2. FOR INTERIOR FINISHES, CABINETRY, FIXTURE
SELECTIONS AND TRIMWORK, REFER TO
INTERIOR DWGS.
1
A300
1
A303
FLOOR ASSEMBLY (1 HR FIRE-RATED):
• NEW FINISH FLOORING
• NEW SOUND MAT
• NEW SUBFLOORING: 1/2" OSB PLY.
• EXIST. WD FRAMING
• NEW SAB BATT INSULATION
• NEW 7/8" RESILIENT CHANNELS AT 16" O.C.
• (2) LAYERS PTD. GWB
REPLACE DOOR AND FRAME
SYSTEM WITH 1HR FIRE-
RATED SELF-CLOSING DOOR
DOOR WIDTH: EXISTING NON-
CONFORMING, SPACE IS
LIMITED
169 SF
LIVING
10S
170 SF
DINING
10T
248 SF
KITCHEN
10U
X3
6
D30
B4
2
B4
2
137 SF
PRIME BEDRM
10H
22 SF
HALF BATH
10C
35 SF
STORAGE
10B
DECK
FIRE-RESISTIVE
SEALANT AT JOINTS
WITH FIRE-RATED
WALLS, TYP.
2
A301
BUILT-IN STORAGE UNDER
STAIR LANDING TO BLOCK
LOW HEIGHT OF LANDING
ABOVE
LINE OF STAIR LANDING
ABOVE
D28
D3
2
D3
2
B42
2
A300
2
A300
RE-FINISH AND RESTORE EXISTING CABINETS
PRESERVE AND REPAIR EXISTING DOORWAY
TRIM WHERE OPENINGS REMAIN, TYP.
D3
2
A
FRAMING PLAN NOTES
FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS
PRIOR TO COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER,
STUDS -STUD GRADE, U.O.N.
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL
DEPTH SOLID BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT
TO HEADER, BAND, RIM JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED
AT EACH INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054
THICK BY 1 1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR
WALLS ARE COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY
STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8.,
602.6(1).(2) R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS
ARE COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN
PREPARED UNDER THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE
CERTIFIED PROFESSIONAL STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED
ENGINEERING PRACTICE (ASCE-7), CROSS-LAMINATED TIMBER TO BE MANUFACTURED AND
IDENTIFIED ACCORDING TO ANSI/APA PRG 320.
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR
BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE
EXTERIOR OF THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
16. ALL PENETRATIONS IN FIRE RATED PARTITIONS TO BE FIRE STOPPED AND SEALED.
17. ALL FIRE AND SMOKE RESISTANCE RATED WALL ASSEMBLIES SHALL BE IDENTIFIED AND
MAINTAIN REQUIRED CONTINUITY.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
TYPE ID
S4
W4a
W4
W4i
F4
F4T
W6
PARTITION ASSEMBLY
1-HOUR SHAFT WALL (UL U305) 1" TYPE X SHAFT LINER ON 4"
H-STUD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1-HOUR FIRE-RATED WALL (UL U305) 5/8" TYPE X GYP BD ON
2X4 WD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2" GYP BD, TYPICAL
U.O.N.
SAME AS W4, WITH CLOSED CELL SPRAY FOAM INSULATION
(MIN. R-20)
1/2" GYP BD ON 2X4 WD FURRING
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2" GYP BD
WALLS WITH THIS SYMBOL INDICATE 3" SOUND-ABSORBING
INSULATION IS ADDED FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND
ATTIC FLOOR
DECK
ROOF (PITCHED)
SNOW
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
30 PSF
100 PSF
20 PSF DEAD
50 PSF GROUND SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
INDICATES POINT LOAD SUPPORTED BELOW
INDICATES POINT LOAD FROM ABOVE
NEW WALL
NEW DOOR
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
0
4
P
M
As indicated
A102
Second Floor Framing & Proposed Plan
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
P R O G R E S S -N O T F O R C O N S T R U C T I O N
1/4" = 1'-0"2 Second Floor Framing Plan
Door & Window Schedule
Door # Quantity Width Height Door Type Glass Type Daylight Area
Heat Transfer
Coefficient (U)Thermal Resistance (R) Fire Rating Comments
X72 1 6' - 0" 6' - 8" Exterior Double Panel
X36 2 3' - 0" 7' - 8" Exterior Single Panel See Product
Documentation Link for
more information
B42 6 3' - 6" 6' - 8" Interior BiFold -
B60 1 5' - 0" 6' - 8" Interior BiFold -
B48 1 4' - 0" 7' - 0" Interior Bifold -
D28 2 2' - 4" 7' - 0" Interior Single Panel
D30 8 2' - 6" 6' - 8" Interior Single Panel -
D32 3 2' - 8" 6' - 8" Interior Single Panel -
D32A 1 2' - 8" 7' - 0" Interior Single Panel 45-MIN CLOSER
D36 4 3' - 0" 6' - 8" Interior Single Panel -
S60 1 5' - 0" 6' - 8" Interior Sliding 2-Panel -
A30 1 2' - 6" 4' - 0" Interior Storage Access - R-30 MIN INSULATED
Window # Count Width Height Head Height Manufacturer Model Daylight Area Vent Area
Heat Transfer
Coefficient
U-Factor
Thermal
Resistance
R-value
Solar Heat Gain
Transmittance
Visible Light
Transmittance Comments
24K 1 2' - 0" 2' - 6" 4' - 6"
31 1 2' - 7" 5' - 10" 7' - 10" Pella Dual Pane Vent 15 SF 14 SF 0.4 2.5 0.4 0.81
36A 6 3' - 0" 5' - 0" 7' - 8" Pella Dual Pane Vent 15 SF 14 SF 0.4 2.5 0.4 0.81
36C 2 2' - 6" 3' - 0" <varies> Pella Casement 0 SF 25 SF 0.4 2.5 0.4 0.81
39K 1 4' - 0" 3' - 6" 6' - 6"
1/4" = 1'-0"3 Second Floor Proposed Plan
No. Description Date
DN
W
REF.
DN
BEDROOM 3
32
BEDROOM 2
33
CL
4
33
A
UNOCCUPIED
SPACE
ALIGN
NEW WINDOW OPENING IN EXTG
EXT. WALL, DBL. 2X10 HEADER
ALIGN FACE OF NEW
VERTICAL WALLS AT
LOCATIONS WHERE SLOPED
HEAD HT IS 4'-0" AFF, TYP.
39K
D30
D30
AL
I
G
N
NEW SPF 2X10
AT 16" O.C.
NE
W
S
P
F
2
X
1
0
AT
1
6
"
O
.
C
.
DBL. 2X10 HEADERS AT
ALL NEW DOOR AND
WINDOW OPENINGS,
TYP.
(2) STUDS E.E.
WALLS UNDER LOW ROOF
AREAS, TYP
2-PLY 1 3/4" X
9 1/2" LVL
D3
0
B42
TYP. FLOOR ASSEMBLY:
• NEW FINISH FLOORING
• NEW SUBFLOORING: 1/2" OSB PLY.
• NEW 2X10 SPF SISTERED TO EXIST. 2X6
WD FRAMING
• NEW SAB BATT INSULATION
• (1) LAYER PTD. GWB
2-PLY 1 3/4" X 9 1/2" LVL
BELOW ROUGH OPENING TO
LOAD-BEARING WALLS BELOW
24K
39K
12" / 12"
12" / 12"
EXISTING ROOF TO REMAIN:
• ASPHALT SHINGLES
• ROOF FELT
• 1X T&G BOARD SHEATHING
• 2X6 AT 24" O.C. WITH NEW
CLOSED CELL SPRAY FOAM
INSULATION (MIN. R-49)
4'
-
7
"
2' - 5"2' - 5"
ALIGN
B42
6'
-
0
"
9'
-
2
"
11
'
-
2
"
2-PL
Y
1
3
/
4
"
X
9
1
/
2
"
L
V
L
13' - 6"7' - 6"
10' - 6"3' - 8"
8'
-
9
"
3'
-
3
"
3'
-
0
"
DECK BELOW
NEW LARGER WINDOW AT EXIST. WINDOW
LOCATION. RE-FRAME ENLARGED ROUGH
OPENING, TYPICAL FOR ALL BEDROOM
WINDOWS.
2-PL
Y
1
3
/
4
"
X
9
1
/
2
"
L
V
L
1
A301
2
A303
1
A302
1
A302
142 SF
BEDROOM 3
32
165 SF
BEDROOM 2
33
11
S
F
CL
4
33
A
UNOCCUPIED
STORAGE
39K
D30
D3
0
WALLS UNDER LOW ROOF
AREAS, TYP
VENT THROUGH
ROOF ABOVE
A3
0
D30
1
A303
DECK BELOW
42 SF
BATHRM
31
156 SF
HALL
30
12
S
F
CL
3
30
A
9 SF
CL 5
32A
9
S
F
CL
6
32
B
DN
2
A300
2
A300
D3
0
B42
B42
(5) TREADS AT 11" MIN. EA
3' - 8"3' - 0" LANDING
LA
N
D
I
N
G
3'
-
2
"
8'
-
6
"
B48
24K
39K
FRAMING PLAN NOTES
FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS
PRIOR TO COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER,
STUDS -STUD GRADE, U.O.N.
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL
DEPTH SOLID BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT
TO HEADER, BAND, RIM JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED
AT EACH INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054
THICK BY 1 1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR
WALLS ARE COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY
STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8.,
602.6(1).(2) R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS
ARE COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN
PREPARED UNDER THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE
CERTIFIED PROFESSIONAL STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED
ENGINEERING PRACTICE (ASCE-7), CROSS-LAMINATED TIMBER TO BE MANUFACTURED AND
IDENTIFIED ACCORDING TO ANSI/APA PRG 320.
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR
BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE
EXTERIOR OF THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
16. ALL PENETRATIONS IN FIRE RATED PARTITIONS TO BE FIRE STOPPED AND SEALED.
17. ALL FIRE AND SMOKE RESISTANCE RATED WALL ASSEMBLIES SHALL BE IDENTIFIED AND
MAINTAIN REQUIRED CONTINUITY.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
TYPE ID
S4
W4a
W4
W4i
F4
F4T
W6
PARTITION ASSEMBLY
1-HOUR SHAFT WALL (UL U305) 1" TYPE X SHAFT LINER ON 4"
H-STUD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1-HOUR FIRE-RATED WALL (UL U305) 5/8" TYPE X GYP BD ON
2X4 WD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2" GYP BD, TYPICAL
U.O.N.
SAME AS W4, WITH CLOSED CELL SPRAY FOAM INSULATION
(MIN. R-20)
1/2" GYP BD ON 2X4 WD FURRING
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2" GYP BD
WALLS WITH THIS SYMBOL INDICATE 3" SOUND-ABSORBING
INSULATION IS ADDED FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND
ATTIC FLOOR
DECK
ROOF (PITCHED)
SNOW
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
30 PSF
100 PSF
20 PSF DEAD
50 PSF GROUND SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
INDICATES POINT LOAD SUPPORTED BELOW
INDICATES POINT LOAD FROM ABOVE
NEW WALL
NEW DOOR
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
10
/
7
/
2
0
2
6
4
:
0
1
:
4
2
P
M
As indicated
A103
Attic Framing & Proposed Plan
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"1 Attic Floor Framing Plan
1/4" = 1'-0"3 Attic Floor Proposed Plan
No. Description Date
Door & Window Schedule
Door # Quantity Width Height Door Type Daylight Area
Heat Transfer
Coefficient (U)Thermal Resistance (R) Fire Rating Comments
X72 1 6' - 0" 6' - 8" Exterior Double Panel 25 SF 0.5510 BTU/(h·ft²·°F) 1.8150 (h·ft²·°F)/BTU -
X36 2 3' - 0" 7' - 8" Exterior Single Panel 12 SF 0.1500 BTU/(h·ft²·°F) 6.6667 (h·ft²·°F)/BTU See Product
Documentation Link for
more information
B42 6 3' - 6" 6' - 8" Interior BiFold -
B60 1 5' - 0" 6' - 8" Interior BiFold -
B48 1 4' - 0" 7' - 0" Interior Bifold -
D28 2 2' - 4" 7' - 0" Interior Single Panel
D30 8 2' - 6" 6' - 8" Interior Single Panel -
D32 3 2' - 8" 6' - 8" Interior Single Panel -
D32A 1 2' - 8" 7' - 0" Interior Single Panel 45-MIN CLOSER
D36 4 3' - 0" 6' - 8" Interior Single Panel -
S60 1 5' - 0" 6' - 8" Interior Sliding 2-Panel -
A30 1 2' - 6" 4' - 0" Interior Storage Access 0.3865 BTU/(h·ft²·°F) 2.5873 (h·ft²·°F)/BTU - R-30 MIN INSULATED
Window # Count Width Height Head Height Daylight Area Thermal Resistance (R)
Heat Transfer
Coefficient (U)Vent Area
Heat Transfer
Coefficient
U-Factor
Thermal
Resistance
R-value
Solar Heat Gain
Transmittance
Visible Light
Transmittance Comments
24K 1 2' - 3" 2' - 6" 4' - 6" 2.5000 (h·ft²·°F)/BTU 0.4000 BTU/(h·ft²·°F)
31A 1 2' - 7" 5' - 10" 7' - 10" 15 SF 1.8146 (h·ft²·°F)/BTU 0.5511 BTU/(h·ft²·°F) 14 SF 0.4 2.5 0.4 0.81
36A 6 3' - 0" 5' - 0" 7' - 8" 15 SF 1.8146 (h·ft²·°F)/BTU 0.5511 BTU/(h·ft²·°F) 14 SF 0.4 2.5 0.4 0.81
36C 1 2' - 6" 3' - 0" 6' - 6" 5 SF 1.8146 (h·ft²·°F)/BTU 0.5511 BTU/(h·ft²·°F) 5 SF 0.4 2.5 0.4 0.81
39K 2 2' - 3" 3' - 6" <varies> 3.0303 (h·ft²·°F)/BTU 0.3300 BTU/(h·ft²·°F)
12" / 12"12" / 12"
12" / 12"
12
"
/
1
2
"
12
"
/
1
2
"
8" / 12"8" / 12"
ROOF OVER 1ST FLOOR
NEW VENT PIPE PENETRATION WITH FLASHING, TYP.
12" / 12"
EXISTING ROOF TO REMAIN:
• EXIST. ASPHALT SHINGLES
• EXIST. ROOF FELT
• EXIST. 1X T&G BOARD SHEATHING
• EXIST. 2X6 AT 24" O.C. WITH NEW CLOSED
CELL SPRAY FOAM INSULATION (MIN. R-39)
• NEW 2" RIGID INSULATION (MIN. R-10)
• NEW 1X WD FURRING & 1/2" GWB AT
FINISHED AREAS ONLY
2-
P
L
Y
1
3
/
4
"
X
1
1
1
/
4
"
L
V
L
10
'
-
0
"
NEW LVL HEADER TO SUPPORT BOTTOM OF
EXISTING ROOF RAFTERS.
CUT RAFTER ENDS BELOW TO CREATE NEW
OPENING FOR OCCUPIED ATTIC SPACES
PATCH ROOF TO RE-COVER
OPENINGS NOT IN USE, TYP.
LINE OF EXTERIOR WALL BELOW
ROOF OVER FRONT DOOR BELOW
1/
4
"
/
1
2
"
ROOF PLAN NOTES
1. ALL DIMENSIONS ARE PROVIDED FOR GENERAL INFORMATION PURPOSES ONLY. CONTRACTOR
SHALL VERIFY ALL DIMENSIONS DURING LAYOUT AND INFORM ARCHITECT OF ANY
DISCREPANCIES OR NECESSARY MODIFICATIONS PRIOR TO PROCEEDING WITH CONSTRUCTION.
2. ± NOTATIONS ARE USED IN DIMENSION STRINGS TO ACCOUNT FOR VARIATIONS BETWEEN
DRAWINGS AND FIELD CONDITIONS.
3. PATCH, REPAIR AND OTHERWISE RECONSTRUCT ROOFING SYSTEMS WHERE NEW WORK
PENETRATES OR OTHERWISE AFFECTS EXISTING ROOFING SYSTEMS, AS REQUIRED TO PROVIDE
A WEATHERTIGHT INSTALLATION. PROVIDE NEW MATERIALS TO MATCH EXISTING SIMILAR
MATERIALS, COMPATIBLE WITH AND FULLY INTEGRATED INTO EXISTING ROOFING SYSTEMS.
4. REPAIR AND RECONSTRUCTION WORK TO EXISTING ROOFING SYSTEMS SHALL BE PROVIDED AS
REQUIRED TO MAINTAIN OWNER'S EXISTING ROOFING WARRANTY AND/OR WARRANTIES.
5. ALL FLASHINGS, COPINGS, SEAMS, AND TRANSITIONS SHALL BE DONE PER ROOFING
MANUFACTURER'S STANDARD DETAILS AND INSTALLATION INSTRUCTIONS.
6. FOLLOW ALL ROOFING SYSTEM MANUFACTURER'S STANDARD INSTALLATION INSTRUCTION AND
DETAILS.
7. INSTALL NON-CORROSIVE FLASHING AT WALL AND ROOF INTERSECTIONS, ROOF SLOPE OR
DIRECTION CHANGES AND AROUND ALL ROOF OPENINGS.
FRAMING PLAN NOTES
FRAMING PLAN LEGEND
1. ALL DIMENSIONS ARE FROM FACE OF FRAMING U.O.N.
2. CONC. CONTRACTOR TO BE RESPONSIBLE FOR ALL CONC. CUTTING & REMOVAL.
3. THE CONTRACTOR SHALL VERIFY EXISTING AND FIELD CONDITIONS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR REQUIRED MODIFICATIONS
PRIOR TO COMMENCING INSTALLATION OF EQUIPMENT AND ASSOCIATED WORK.
4. PROVIDE DOUBLE STUDS AT JAMBS OF ALL DOORS, WINDOWS AND SIMILAR OPENINGS.
5. ALL CONNECTORS USED IN PRESSURE-TREATED WOOD FRAMING SHALL BE STAINLESS OR
GALVANIZED STEEL.
6. ALL HEADERS, FLOOR JOISTS & RAFTERS ARE TO BE SPRUCE-PINE-FIR #2 OR BETTER,
STUDS -STUD GRADE, U.O.N.
7. ALL HEADERS ARE TO BE 3-2X10'S UNLESS OTHERWISE SPECIFIED.
8. JOISTS:
A. SHALL BE SUPPORTED LATERALLY (TO PREVENT ROTATION) AT THE ENDS BY FULL
DEPTH SOLID BLOCKING NOT LESS THAN 2" NOMINAL THICKNESS OR BY ATTACHMENT
TO HEADER, BAND, RIM JOIST, OR TO AN ADJOINING STUD.
B. IN SEISMIC DESIGN CATEGORIES D1 AND D2, LATERAL RESTRAINT MUST BE PROVIDED
AT EACH INTERMEDIATE SUPPORT R502.7.
9. NOTCHING REQUIREMENTS FOR EXTERIOR LOAD BEARING WALLS:
A. LOAD BEARING WALLS CUT MORE THAN 50% MUST BE SECURED BY A METAL TIE .054
THICK BY 1 1/2 INCHES WIDE WITH 8-16D NAILS ON EACH SIDE EXCEPT WHERE EXTERIOR
WALLS ARE COVERED BY SHEATHING.
B. HOLES BETWEEN 40% AND 60% OF STUD DEPTH REQUIRE DOUBLE STUDS.
C. NO HOLES ARE PERMITTED WITHIN 5/8 INCH OF THE EDGE OF ANY STUD.
D. NO HOLES ARE PERMITTED WITHIN ON THE SAME CROSS SECTION AS A NOTCH ON ANY
STUD.
E. NO NOTCHES ARE PERMITTED TO BE MORE THAN 25% OF THE STUD DEPTH . R502.8.,
602.6(1).(2) R602.6.1
10. ALL HEADERS, GIRDERS SUPPORTING BEAMS AND OTHER STRUCTURAL COMPONENTS
ARE COVERED UNDER R301.1.3 ENGINEERED DESIGN. THESE DRAWINGS HAVE BEEN
PREPARED UNDER THE DIRECT SUPERVISION AND SEALED BY A NEW YORK STATE
CERTIFIED PROFESSIONAL STRUCTURAL ENGINEER IN ACCORDANCE WITH ACCEPTED
ENGINEERING PRACTICE (ASCE-7), CROSS-LAMINATED TIMBER TO BE MANUFACTURED AND
IDENTIFIED ACCORDING TO ANSI/APA PRG 320.
11. ALL TOP PLATES AND SILL PLATES SHALL BE #3 SYP OR DFL (19% MC) OR BETTER.
12. HEADERS, FLUSH BEAMS, AND DROP BEAMS SHALL BE #2 DFL OR SYP (19%MC) OR
BETTER, U.O.N.
13. ALL HEADERS AND BEAMS SHALL HAVE DOUBLE STUD PACK UNDER EACH END, U.O.N.
14. SIMPSON CS20 X 48" LONG STRAPS SPACED AT 48" O.C. SHALL BE USED ALONG THE
EXTERIOR OF THE BUILDING CENTERED ACROSS THE FLOOR CAVITY.
15. THE STABILITY OF THE FLOOR IS NOT ACHEIVED UNTIL THE DECKING HAS BEEN PROPERLY
INSTALLED AND FASTENED.
16. ALL PENETRATIONS IN FIRE RATED PARTITIONS TO BE FIRE STOPPED AND SEALED.
17. ALL FIRE AND SMOKE RESISTANCE RATED WALL ASSEMBLIES SHALL BE IDENTIFIED AND
MAINTAIN REQUIRED CONTINUITY.
EXISTING WALL TO REMAIN
EXISTING DOOR AND FRAME
TO REMAIN
TYPE ID
S4
W4a
W4
W4i
F4
F4T
W6
PARTITION ASSEMBLY
1-HOUR SHAFT WALL (UL U305) 1" TYPE X SHAFT LINER ON 4"
H-STUD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1-HOUR FIRE-RATED WALL (UL U305) 5/8" TYPE X GYP BD ON
2X4 WD FRAMING WITH BATT INSULATION AT 16" O.C. ON 5/8"
TYPE X GYP BD
1/2" GYP BD ON 2X4 WD FRAMING ON 1/2" GYP BD, TYPICAL
U.O.N.
SAME AS W4, WITH CLOSED CELL SPRAY FOAM INSULATION
(MIN. R-20)
1/2" GYP BD ON 2X4 WD FURRING
1/2" GYP BD ON TURNED 2X4 WD FURRING
1/2" GYP BD ON 2X6 WD FRAMING ON 1/2" GYP BD
WALLS WITH THIS SYMBOL INDICATE 3" SOUND-ABSORBING
INSULATION IS ADDED FOR ACOUSTICAL INSULATION
DESIGN LOADS:
FIRST FLOOR
SECOND
ATTIC FLOOR
DECK
ROOF (PITCHED)
SNOW
LOADS:
40 PSF LIVE / 10 PSF DEAD
40 PSF LIVE / 10 PSF DEAD
30 PSF
100 PSF
20 PSF DEAD
50 PSF GROUND SNOW
20 PSF DEAD
115 MPH WIND
EXPOSURE: B
INDICATES POINT LOAD SUPPORTED BELOW
INDICATES POINT LOAD FROM ABOVE
NEW WALL
NEW DOOR
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
0
5
P
M
As indicated
A104
Roof Removal, Framing and Proposed Plan
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"2 Roof Framing Proposed Plan
No. Description Date
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
13
'
-
9
1
/
2
"
9'
-
5
"
11
'
-
3
1
/
2
"
7'
-
6
1
/
2
"
Ex. Attic
20' -8 1/2"
ORIGINAL HISTORIC BLDG
EXISTING TO REMAIN NEW ADDITION
NEW RETAINING WALL AT MIN. +1' -0"
ABOVE GRADE PLANE
Addition T.O.S.
-8' -6"
RE-GRADE EXTG EARTH 1:2 SLOPE MAX. FROM
ORIGINAL BLDG TO END OF RETAINING WALL
S.M. FLASHING UNDER
SIDING, TYP.
NEW WALL PENETRATION
FOR STOVE HOOD EXHAUST
NEW EGRESS WINDOW
& WINDOW WELL
NEW WOOD GUARD
RAIL, TYP.
1/4"
12"
36C Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
X72
36A 36A
11
1
/
2
"
3'
-
6
1
/
2
"
4'
-
0
"
11
'
-
3
1
/
2
"
9'
-
5
"
13
'
-
9
1
/
2
"
SLOPE SLOPE
Addition T.O.S.
-8' -6"
REPLACE EXISTING TRIANGULAR-
TOPPED WINDOW, REPAIR ROUGH
OPENING. PROVIDE WD SUPPORT,
SMART TRIM AND SILL.
ROOF TYPE 3 (DECK ON TPO ROOF)
1x4 TREX DECKING ON PRESSURE-TRD WD
SLEEPERS ON TPO MEMBRANE FULLY
ADHERED WITH HEAT-WELDED SEAMS ON
5/8" THK COVER BOARD ON R-10 (MIN. 2")
RIGID INSULATION ON 3/4" THK EXTERIOR
GRADE PLY SHEATHING ON 2X10 WD
FRAMING AT 16" O.C. WITH R-19 FACED BATT
INSULATION
REPAIR EXISTING LOUVERED ATTIC
VENTS TO REMAIN, PAINT SAME
COLOR AS TRIM
36A 36A 36AEXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
X36
NEW WINDOW AT EXISTING LOCATION TO
MATCH ORIGINAL CONSTRUCTION AT
ADJACENT WINDOWS
NEW DOOR TO ACCESS ROOF DECK AT
SAME LOCATION AS EXISTING WINDOW
39K
31A
AR
E
A
2'
-
1
0
"
C
L
R
AREA
2' - 3" CLR
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
EXISTING TO REMAIN
13
'
-
9
1
/
2
"
9'
-
5
"
11
'
-
3
1
/
2
"
4'
-
0
"
NEW RAILING ON EXTG
STAIR, 3' -6" HT
PATCH AND REPAIR EXTG STAIR AND
FRONT DOOR, STAIN AND SEAL
SCRAPE, PATCH, REPAIR ALL
EXISTING WOOD TRIMWORK AND
DOOR AWNINGS. PAINT
ACCORDING TO OWNER'S
SELECTED COLOR, TYP.
76
ADDRESS IDENTIFICATION
NEW PAINT ON EXTG WOOD SHINGLES
NEW EGRESS WINDOW WELL
24K
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
NEW WINDOW AT ATTIC
BEDROOM
36A
39K
13
'
-
9
1
/
2
"
9'
-
5
"
11
'
-
3
1
/
2
"
4'
-
0
"
3'
-
6
1
/
2
"
SCRAPE, PATCH, REPAIR ALL EXISTING WOOD TRIMWORK
AND DOOR AWNINGS. PAINT ACCORDING TO OWNER'S
SELECTED COLOR, TYP.
REPAIR EXISTING BASEMENT WINDOWS AND
RETROFIT FOR NEW MECHANICAL WORK
EXTERIOR WALL -WD SHAKE SIDING ON 2X8
PTD WD SHAKES ON WEATHER BARRIER ON
3/4" EXT. GRADE PLY SHEATHING ON 2X8 WD
FRAMING AT 16" O.C. WITH R-21 BATT
INSULATION ON VAPOR BARRIER ON PTD. 1/2"
GWB
3'
-
7
"
NEW ADDITION EXISTING TO REMAIN
X36
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
10
/
7
/
2
0
2
6
4
:
0
2
:
0
8
P
M
3/16" = 1'-0"
A200
Exterior Elevations
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
3/16" = 1'-0"1 West Elevation
3/16" = 1'-0"2 South Elevation
3/16" = 1'-0"3 North Elevation
3/16" = 1'-0"4 East Elevation
No. Description Date
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
1
A301
2
A303
Addition T.O.S.
-8' -6"
2
A301
HALL
30
BATHRM
31
BEDROOM 2
33
KITCHEN
13
HALL
10Q
BATHRM
10P
PLAYROOM
24
2
A300
8'
-
0
"
C
H
8'
-
8
"
C
H
PASSAGE
21
CL
23A
EXISTING ROOF TO REMAIN:
• EXIST. ASPHALT SHINGLES
• EXIST. ROOF FELT
• EXIST. 1X T&G BOARD SHEATHING
• EXIST. 2X6 AT 24" O.C. WITH NEW CLOSED
CELL SPRAY FOAM INSULATION (MIN. R-39)
• NEW 2" RIGID INSULATION (MIN. R-10)
• NEW 1X WD FURRING & 1/2" GWB AT
FINISHED AREAS ONLY
NEW CLOSED CELL SPRAY
INSULATION (MIN R-30) AT
EXISTING EXTERIOR WALL
BRICK ON 2X6 WD FRAMING TO
REMAIN, TYP.
CONTINUOUS 1-HOUR FIRE-RATED
SEPARATION REQUIRED AT SECOND
FLR FLOOR ASSEMBLY, AND STAIR
ENCLOSURE.
PROVIDE NEW COLLAR TIES AT NEW
CEILING CONSTRUCTION.
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
1
A302
Addition T.O.S.
-8' -6"
1
A300
BATHRM
31
BEDROOM 3
32
HALL
30
DINING
10T KITCHEN
10U
DINING
17
KITCHEN
13
LIVING
12
FAMILY ROOM
25
PASSAGE
21
CL
23A
BEDROOM
23
STRUC BEAM SUPPORT
NON-STRUC SOFFIT
NEW ADDITIONORIGINAL BUILDING
9'
-
7
"
8'
-
0
"
HALF BATH
10C
ROOF TYPE 3 (DECK ON TPO ROOF)
1x4 TREX DECKING ON PRESSURE-TRD WD
SLEEPERS ON TPO MEMBRANE FULLY
ADHERED WITH HEAT-WELDED SEAMS ON
5/8" THK COVER BOARD ON R-10 (MIN. 2")
RIGID INSULATION ON 3/4" THK EXTERIOR
GRADE PLY SHEATHING ON 2X10 WD
FRAMING AT 16" O.C. WITH R-19 FACED BATT
INSULATION
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
1/2" GWB ON NEW 2X6 WD AT 24" OC.
RAFTER TIES
FLOOR ASSEMBLY (NEW)
NEW FINISH FLOORING ON NEW SOUND MAT
ON 1/2" OSB PLY. SUBFLOOR ON 2X10 SP #1
WD FRAMING AT 12" O.C. WITH SAB BATT
INSULATION ON 7/8" RESILIENT CHANNELS AT
12" O.C. ON (1) LAYER PTD. GWB CEILING
FOUNDATION FLOOR
4" CONC. WITH 6X6 W2.9 W.W.F. ON 6 MM
POLYETHYLENE VAPOR BARRIER ON R-10
POLYISOCYANURATE RIGID INSULATION ON
4" COMPACTED GRAVEL BASE
X72
36A
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
1
7
P
M
1/4" = 1'-0"
A300
Overall Building Sections
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/4" = 1'-0"1 Building Cross-Section North-South
1/4" = 1'-0"2 Overall Building Section East-West
No. Description Date
14
15Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Basement
-7' -6 1/2"
Ex. Attic
20' -8 1/2"
T/O LANDING
Addition T.O.S.
-8' -6"
T/O FOUNDATION WALL
8'
-
6
"
36A
PROVIDE NEW 1/2" GYP BD (PTD
FINISH) AND CLOSED CELL SPRAY
FOAM INSULATION (R-20 MIN.) TO
EXTG ATTIC 2X4 WD FRAMING,
TYP.
T/O SILL HT
PROTECTIVE BOARD ON R-10
RIGID INSULATION, TYP.
ORIGINAL STONE FOUNDATION
WALL TO REMAIN
F42X4 WD FRAMING ON SHIMS ON EXTG
STONE FOUNDATION WALL, WALLS
TO BE PLUMB, TYP.
CONTRACTOR TO V.I.F. TOP OF WALL
CONDITION, SECURE NEW STRUCTURAL
FRAMING TO EXISTING
PROVIDE NEW HDWD FLOOR FINISH
ON NEW FLOOR STRUCTURAL
ASSEMBLY, TYP.
EXIST. BRICK ON 2X4 WD FRAMING TO
REMAIN. REMOVE INSULATION IN CAVITY AT
NEW ADDITION LOCATIONS. RE-FINISH WITH
PTD 1/2" THK. GWB.
A302
6
A500
5
LEDGER, P.T. 2X10 THRU-BOLTED TO RIM
W/2 GALV. 1/2" BOLTS OR LAG BOLTED
WITH LEDGE LOCK, TYP.
LEDGER, P.T. 2X10 THRU-BOLTED TO RIM
W/2 GALV. 1/2" BOLTS OR LAG BOLTED
WITH LEDGE LOCK, TYP.
A500
10
GUTTER, TYP.
7' - 4 1/2" ABOVE SLAB
137 SF
PRIME BEDRM
10H
157 SF
BEDROOM
14
367 SF
LIVING
12
ELEC RM
10Z
INFILL WALL AT DOOR OPENING TO MATCH
ADJACENT WALL CONSTRUCTION WITH
SALVAGED BRICK ON 2X4 WD FRAMING. FINISH
WITH PTD 1/2" THK. GWB.
X36
+ 9' - 7" AFF
B/O FIN. CLG
1/2" GWB ON 2X4 WD FRAMING WITH CLOSED
CELL SPRAY INSULATION (MIN. R-20ci) BETWEEN
STUDS SECURED TO FOUNDATION WALL, TYP.
1/2" FOAM ISOLATION JOINT
EXISTING CONC. FOOTING, V.I.F.
FOUNDATION FLOOR
4" CONC. WITH 6X6 W2.9 W.W.F. ON 6 MM
POLYETHYLENE VAPOR BARRIER ON R-10
POLYISOCYANURATE RIGID INSULATION ON
4" COMPACTED GRAVEL BASE
2
R
I
S
E
R
S
A
T
6
3
/
4
"
E
A
.
1'
-
1
"
3' - 6" MIN.
FLOOR ASSEMBLY (1 HR FIRE-RATED)
NEW FINISH FLOORING ON NEW SOUND MAT
ON NEW 1/2" OSB PLY. SUBFLOOR ON EXIST.
WD 2X10 FRAMING WITH NEW SAB BATT
INSULATION ON NEW 7/8" RESILIENT
CHANNELS AT 16" O.C. ON (2) LAYERS PTD.
TYPE X GWB CEILING
CL
25A
ELEC RM
10Z
FLOOR ASSEMBLY (NEW)
NEW FINISH FLOORING ON NEW SOUND MAT
ON 1/2" OSB PLY. SUBFLOOR ON 2X10 SP #1
WD FRAMING AT 12" O.C. WITH SAB BATT
INSULATION ON 7/8" RESILIENT CHANNELS AT
12" O.C. ON (1) LAYER PTD. GWB CEILING
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
Ex. Attic
20' -8 1/2"
1
A302
Addition T.O.S.
-8' -6"
LEDGER, P.T. 2X10 THRU-BOLTED TO
RIM W/ 2 GALV. 1/2" BOLTS OR LAG
BOLTED WITH LEDGE LOCK, TYP.
7'
-
6
"
C
H
FLOOR ASSEMBLY (NEW)
NEW FINISH FLOORING ON NEW SOUND MAT
ON 1/2" OSB PLY. SUBFLOOR ON 2X10 SP #1
WD FRAMING AT 12" O.C. WITH SAB BATT
INSULATION ON 7/8" RESILIENT CHANNELS AT
12" O.C. ON (1) LAYER PTD. GWB CEILING
FOUNDATION FLOOR
4" CONC. WITH 6X6 W2.9 W.W.F. ON 6 MM
POLYETHYLENE VAPOR BARRIER ON R-10
POLYISOCYANURATE RIGID INSULATION ON
4" COMPACTED GRAVEL BASE
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
(2
)
R
I
S
E
R
S
A
T
5
1
/
4
"
H
E
A
11
1
/
2
"
1/2" THK PTD. GWB ON 2X4 WD STUD
FRAMING SISTERED LEVEL TO SLOPED
ROOF STRUC. JOISTS. BLOCKING AS
REQUIRED
ROOF TYPE 3 (DECK ON TPO ROOF)
1x4 TREX DECKING ON PRESSURE-TRD WD
SLEEPERS ON TPO MEMBRANE FULLY
ADHERED WITH HEAT-WELDED SEAMS ON
5/8" THK COVER BOARD ON R-10 (MIN. 2")
RIGID INSULATION ON 3/4" THK EXTERIOR
GRADE PLY SHEATHING ON 2X10 WD
FRAMING AT 16" O.C. WITH R-19 FACED BATT
INSULATION
3'
-
6
"
M
I
N
.
FLOOR TYPE 3 (ATTIC)
NEW FLOOR FINISH ON 3/4" PLY SUBSTRATE
ON SPF 2x10 AT 16" O.C. (TOP TO BE FLUSH
WITH EX. 2X6 JOISTS) ON 1/2" GWB
TOP OF CONC. RETAINING WALL
BEDROOM 3
32
KITCHEN
10U
KITCHEN
13
LIVING
12
FAMILY ROOM
25
PASSAGE
21
DRILL AND EPOXY #4 DOWELS INTO
EXISTING FOOTING AT 24" O.C.
TRENCH DRAIN TO PERFORATED DRAIN
AT FOUNDATION FOOTING
RECONSTRUCT EDGE OF CONC.
SLAB AT NEW OPENING
EXIST. HDWD FIN FLR ON F.J. TO BE
SANDED AND REFINISHED, TYP.
WD CROSS-BRACING SUPPORT, TYP.
WD BLOCKING
2-PLY 1 3/4" X 14" LVL HDR
STL LINTEL L5X3-1/2X1/2
A302
3
NEW DRIP EDGE METAL FLASHING AT
BOTTOM OF BRICK, TYP.
39K
36A
X72
2'
-
8
"
36A
X36
NEW CLOSED CELL SPRAY
INSULATION (MIN R-30) AT
EXISTING EXTERIOR WALL
BRICK ON 2X6 WD FRAMING TO
REMAIN, TYP.
FLOOR ASSEMBLY (1 HR FIRE-RATED)
NEW FINISH FLOORING ON NEW SOUND MAT
ON NEW 1/2" OSB PLY. SUBFLOOR ON EXIST.
WD 2X10 FRAMING WITH NEW SAB BATT
INSULATION ON NEW 7/8" RESILIENT
CHANNELS AT 16" O.C. ON (2) LAYERS PTD.
TYPE X GWB CEILING
GUTTER, TYP.
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
2
0
P
M
1/2" = 1'-0"
A301
Building Sections at Addition
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/2" = 1'-0"1 Overall Section at Asphalt Roof Typical
1/2" = 1'-0"2 Section 1
No. Description Date
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15 Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
1
A301
1
A301
Addition T.O.S.
-8' -6"
OPEN TO
BEYOND
OPEN TO
BEYOND
UNOCCUPIED
SPACE UNDER
STAIR
FINISH FLOOR, SEE
INTERIOR DWGS, TYP.
(4
)
R
I
S
E
R
S
A
T
7
"
E
A
8'
-
6
"
A302
2
A302
4
A302
8
7'
-
7
"
C
H
EXTERIOR WALL -LAP SIDING ON 2X8
HARDIPLANK SIDING ON WEATHER BARRIER
ON 3/4" EXT. GRADE PLY SHEATHING ON 2X8
WD FRAMING AT 16" O.C. WITH R-21 BATT
INSULATION ON VAPOR BARRIER ON PTD. 1/2"
GWB (TYPICAL AT 1ST FL)
ROOF TYPE 3 (DECK ON TPO ROOF)
1x4 TREX DECKING ON PRESSURE-TRD WD
SLEEPERS ON TPO MEMBRANE FULLY
ADHERED WITH HEAT-WELDED SEAMS ON
5/8" THK COVER BOARD ON R-10 (MIN. 2")
RIGID INSULATION ON 3/4" THK EXTERIOR
GRADE PLY SHEATHING ON 2X10 WD
FRAMING AT 16" O.C. WITH R-19 FACED BATT
INSULATION
FOUNDATION FLOOR
4" CONC. WITH 6X6 W2.9 W.W.F. ON 6 MM
POLYETHYLENE VAPOR BARRIER ON R-10
POLYISOCYANURATE RIGID INSULATION ON
4" COMPACTED GRAVEL BASE
FLOOR ASSEMBLY (NEW)
NEW FINISH FLOORING ON NEW SOUND MAT
ON 1/2" OSB PLY. SUBFLOOR ON 2X10 SP #1
WD FRAMING AT 12" O.C. WITH SAB BATT
INSULATION ON 7/8" RESILIENT CHANNELS AT
12" O.C. ON (1) LAYER PTD. GWB CEILING
36A
METAL TERMITE SHIELD AT 45
DEG. ANGLE, SEAL ALL SEAMS
AND HOLES, TYP.
BITUMINOUS, FIBERGLASS
REINF. DAMP PROOFING
2X6 TREATED WOOD PLATE W/ 1/2" 10"
8" CONC. FOUNDATION WALLS, #4 VERTICAL
REBAR AT 4'-0" OC., 6" INTO FOOTING
2
A301
2
A301
EQ
EQ
1/2" GWB ON 2X4 WD FRAMING WITH
CLOSED CELL SPRAY INSULATION (MIN.
R-13) BETWEEN STUDS SECURED TO
FOUNDATION WALL, TYP.
4'
-
0
"
T
Y
P
.
11
1
/
2
"
INFILL OPENING WITH BRICK ON WD
FRAMING TO MATCH ADJ.
+ 7' - 4 1/2" AFF
TOP OF LANDING
(1
3
)
R
I
S
E
R
S
A
T
6
3
/
4
"
E
A
.
7'
-
4
"
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
ROOF TYPE 3 (DECK ON TPO ROOF)
1x4 TREX DECKING ON PRESSURE-TRD WD
SLEEPERS ON TPO MEMBRANE FULLY
ADHERED WITH HEAT-WELDED SEAMS ON
5/8" THK COVER BOARD ON R-10 (MIN. 2")
RIGID INSULATION ON 3/4" THK EXTERIOR
GRADE PLY SHEATHING ON 2X10 WD
FRAMING AT 16" O.C. WITH R-19 FACED BATT
INSULATION
HOT WELD PER TPO MANF.
EXTERIOR SILICONE SEALANT
PER TPO MANF. SPEC
METAL EDGE FLASHING PER TPO MANF.
METAL COUNTERFLASHING
PER TPO MANF. SECURED
TO WD BLOCKING, TYP.
EXTERIOR SILICONE SEALANT
PTD. 1X SMART TRIM FRIEZE
SELF-ADHERED FLASHING ON 1/2"
PLY ON WD BLOCKING
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
Ex. First Floor
0' -0"
EXT INT
PROTECTIVE FOUNDATION PRE-MIXED
100% ACRYLIC TROWEL-ON COATING
DOWN TO -12" BELOW GRADE
METAL TERMITE SHIELD AT 45 DEG.
ANGLE, 1 1/2" MIN. LENGTH, SEAL ALL
SEAMS AND HOLES, TYP.
CONT. WEATHER BARRIER
POLYETHYLENE SELF-ADHERED
MEMBRANE FLASHING OVERLAPPING
WEATHER BARRIER AND TOP OF
FOUNDATION WALL ASSEMBLY
2" THK RIGID INSULATION, TYP.
SILL SEALER, TYP.
2X6 PRT WD PLATE 1 1/2" DIA. #10 LG
ANCHOR BOLTS AT 48" O.C., TYP.
BITUMINOUS, FIBERGLASS REINF.
DAMPPROOFING, TYP.2X4 WD FURRING ON CONC.
FOUNDATION WALL, TYP.
1/2" PTD. GWB ON CLOSED
CELL SPRAY FOAM INSULATION
(MIN R-13), TYP.
TYP. FOUNDATION WALL
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
WEB STIFFENER & CLOSED CELL SPRAY FOAM
AT JOIST ENDS, TYP.
Ex. First Floor
0' -0"
PROTECTIVE FOUNDATION PRE-MIXED
100% ACRYLIC TROWEL-ON COATING
DOWN TO -12" BELOW GRADE
METAL TERMITE SHIELD AT 45 DEG. ANGLE, 1 1/2"
MIN. LENGTH, SEAL ALL SEAMS AND HOLES, TYP.
CONT. WEATHER BARRIER, TYP.
POLYETHYLENE SELF-ADHERED
MEMBRANE FLASHING OVERLAPPING
WEATHER BARRIER AND TOP OF
FOUNDATION WALL ASSEMBLY, TYP.
2" THK RIGID INSULATION, TYP.
SILL SEALER, TYP.
2X6 PRT WD PLATE 1 1/2" DIA. 10 LG
ANCHOR BOLTS AT 48" O.C., TYP.
BITUMINOUS, FIBERGLASS REINF.
DAMPPROOFING, TYP.
2X4 WD FURRING ON CONC.
FOUNDATION WALL, TYP.
1/2" PTD. GWB ON CLOSED
CELL SPRAY FOAM INSULATION
(MIN R-13), TYP.
EXT
TYP. SIDING
1X12 FREIZE BOARD
TYP. FOUNDATION WALL
2X12 HDWD STAIR STRINGER, TYP.
2X6 HDWD STAIR LANDING
EXTERIOR WALL -PTD BD ON 2X8
PTD 3/4" THK BOARD ON CONT. WEATHER
BARRIER ON 1/2" EXT GRADE PLY SHEATHING
ON 2X8 WD FRAMING WITH FACED BATT
INSULATION (MIN R-21) ON PTD 1/2" GWB
INT
Addition T.O.S.
-8' -6"
TYP. FOOTING
1' - 4"
BITUMINOUS, FIBERGLASS
REINF. FOUNDATION
DAMPPROOFING, TYP.
3/4" STONE SURROUND
WRAPPED IN GEO-FABRIC WRAP,
TYP.
6" DIA. PERFORATED PVC
DRAINPIPE, TYP
1" COMPRESSIBLE FILL AT FLOOR
EDGE, TYP
FOUNDATION FLOOR
4" CONC. WITH 6X6 W2.9 W.W.F. ON 6 MM
POLYETHYLENE VAPOR BARRIER ON R-10
POLYISOCYANURATE RIGID INSULATION ON
4" COMPACTED GRAVEL BASE
TYP. WALL
8"1/2" GWB ON 2X4 WD FRAMING WITH
CLOSED CELL SPRAY INSULATION (MIN.
R-13) BETWEEN STUDS SECURED TO
FOUNDATION WALL, TYP.
2-#4 REBAR TOP & BTM (TYP)
2X4 STOUT KEYWAY
PVC WATERSTOP
8"
8" CONC. FOUNDATION WALLS, #4
VERTICAL REBAR AT 4'-0" OC., 6" INTO
FOOTING, TYP.
Addition T.O.S.
-8' -6"
9 1/4"
-9' - 6"
T/O FOOTING
POLYETHYLENE VAPOR
BARRIER, TYP.
R-10 XPS RIGID INSULATION
4" CONC SLAB
SELF-ADHERED MEMBRANE ACROSS
JOINTS, UNDER SILL, AND EXTEND EXTERIOR
SIDE UNDER DRAINAGE MAT
4" GRAVEL
6" PERF. PVC DRAINAGE PIPE, TYP.
6" X 6" TRENCH DRAIN EMBEDDED INTO
CONC. SLAB, CENTER LINE ALIGNED WITH
ROOF EDGE OVERHANG ABOVE
BLUESTONE ON 4" CONC.
ON 4" GRAVEL
DRAINAGE MAT
EXTEND R-10 XPS RIGID INSULATION
TO TRENCH DRAIN
TYP. FINISH FLOOR 1' - 8"
1/4" / 12"
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
2
2
P
M
As indicated
A302
Building Section and Details at Addition
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/2" = 1'-0"1 Building Cross Section at Stair
1 1/2" = 1'-0"2 Section Detail at Typical TPO Roof Edge
1 1/2" = 1'-0"4 Section Detail at Typical Sill Detail
1 1/2" = 1'-0"6 Section Detail at Top Sill at Stair Stringer
1 1/2" = 1'-0"8 Typ. Section Detail at Bottom of Foundation Wall
1 1/2" = 1'-0"3 Section Detail at Foundation & Door Sill
No. Description Date
Ex. First Floor
0' -0"
Ex. Second Floor
11' -3 1/2"
Ex. Attic
20' -8 1/2"
ENTRY
10
NEW PTD. GWB FINISH AT FLOOR
EDGE, WD BLOCKING, TYP.
17
R
I
S
E
R
S
A
T
8
"
E
A
EX
I
S
T
I
N
G
N
O
N
-
C
O
N
F
O
R
M
I
N
G
S
T
A
I
R
11
'
-
3
1
/
2
"
TOP OF LANDING
EXISTING LOAD-BEARING
WALL BEYOND TO REMAIN
NEW PTD. (2) LAYERS 5/8" TYPE X
GWB ON WD FRAMING ON NEW STL
BEAM, TYP.
1 3/4" X 9 1/4" LVL, SEE
FRAMING PLAN
2X12 HDWD STAIR STRINGER
(CLOSED) AT WALL SIDE
2X6 HDWD LANDING
EXISTING ROOF ASSEMBLY AND
RAFTERS TO REMAIN
1
1
/
2
"
FLOOR TYPE 3 (ATTIC)
NEW FLOOR FINISH ON 3/4" PLY SUBSTRATE
ON SPF 2x10 AT 16" O.C. (TOP TO BE FLUSH
WITH EX. 2X6 JOISTS) ON 1/2" GWB HEAD CLR OBSTRUCTION MAX.
1
A300
1
A303
6'
-
0
3
/
4
"
8'
-
7
1
/
4
"
C
H
+ 6' - 9" AFF
STORAGE
10B
HALL
30
CL 6
32B
KITCHEN
10U
KITCHEN
13
3'
-
0
"
M
I
N
.
FLOOR ASSEMBLY (1 HR FIRE-RATED)
NEW FINISH FLOORING ON NEW SOUND MAT
ON NEW 1/2" OSB PLY. SUBFLOOR ON EXIST.
WD 2X10 FRAMING WITH NEW SAB BATT
INSULATION ON NEW 7/8" RESILIENT
CHANNELS AT 16" O.C. ON (2) LAYERS PTD.
TYPE X GWB CEILING
EXISTING STAIR & RAIL TO REMAIN
EXISTING FRONT ENTRY
DOOR TO REMAIN
EXISTING EXTERIOR
FEATURES TO REMAIN
EXISTING WINDOW TO REMAIN
NEW CLOSED CELL SPRAY
INSULATION (MIN R-30) AT
EXISTING EXTERIOR WALL
BRICK ON 2X6 WD FRAMING TO
REMAIN, TYP.
NEW CLOSED CELL SPRAY
INSULATION (MIN R-30) AT
EXISTING EXTERIOR WALL WD
SIDING ON 2X6 WD FRAMING TO
REMAIN, TYP.
ACOUSTIC BATT INSULATION IN
WALLS ADJACENT TO STAIRS, TYP.
(1
2
)
R
I
S
E
R
S
A
T
6
3
/
4
"
E
A
6'
-
9
"
7'
-
0
"
Ex. Second Floor
11' -3 1/2"
T/O Roof
34' -6"
Ex. Attic
20' -8 1/2"
2
A303
2
A300
UNOCCUPIED
SPACE UNDER
STAIR
HALL
30
DINING
10T
STORAGE
10B
OPEN TO BEYOND
+ 6' - 9" AFF
(5
)
R
I
S
E
R
S
A
T
6
3
/
4
"
E
A
2'
-
9
"
T/O LANDING
3'
-
0
"
M
I
N
.
1/2" PTD. GWB ON ED
BLOCKING AT UNDERSIDE
OF STAIR
7'
-
0
"
CUSTOM SHELVING BELOW
STAIR CONSTRUCTION AT
HEIGHTS UNDER 7'-0" HT AFF
6'
-
1
"
Ex. First Floor
0' -0"
Ex. Basement
-7' -6 1/2"
Grade
-4' -0"
EXISTING EXTERIOR WALL
TO REMAIN, TYP.
EXISTING FOUNDATION WALL TO REMAIN, TYP.
TYPICAL FOUNDATION
ASSEMBLY, REFER TO TYP.
FOOTING DETAIL
4" DEPTH GRAVEL BASE AT BOTTOM
OF EGRESS WELL
TYP. 8" THK. CONC. WALL
EGRESS LADDER FROM TOP OF EGRESS
WELL TO TOP OF CONCRETE WALL
1'
-
0
"
M
I
N
.
Ex. First Floor
0' -0"
Grade
-4' -0"
1' -6" DIA. CONC. FOOTINGS, MIN. 4' -0"
DEEP BELOW GRADE AT EACH WD
POST COLUMN
4X4 PRTD WD
POST COLUMNS
(2) 2X10 PRTD WD FRAMING
HANDRAIL, MIN 36" FROM TOP OF STEP,
SECURED TO WD FRAMING BELOW TO
RESIST MIN. 250#, TYP.
4" THK CONC. PAD LANDING ON
4" GRAVEL
SECURE BOTTOM OF STRINGER
TO CONC. PAD
2X TREX COMPOSITE DECK
BOARD ON PRTD WD FRAMING
Scale
Project number
Date
devon telberg, aia
388 Greenway
Albany, NY 12208
t (518) 212-7778
e devon@telbergstudio.com P R O G R E S S -N O T F O R C O N S T R U C T I O N
9/
2
2
/
2
0
2
6
4
:
3
2
:
2
4
P
M
1/2" = 1'-0"
A303
Sections at Stairs & Egress
2404
The Bergman Residence
5/27/26
76 Walton St.
Saratoga Springs, NY 12866
76 Walton St Addition & Renovation
1/2" = 1'-0"2 Section at Attic Stair - East-West
1/2" = 1'-0"1 Cross-Section at Attic Stair
1/2" = 1'-0"3 Section at Basement Egress Window
1/2" = 1'-0"4 Section at Rear Deck Entrance
No. Description Date