Loading...
HomeMy WebLinkAbout20260793 Henning Rd Verizon Utility Pole Modification NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Karen Cavotta Karen D’Andrea Leslie DiCarlo Jeff Pfeil Geoff Wood Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20260793 Henning Road Verizon Utility Pole-Modification Henning Road Saratoga Springs, New York 12866 involving Architectural review of a modification to an approved application for the collocation of a utility pole and wireless equipment in the right of way within the Rural Residential (RR) District, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on September 23, 2026:  Approve the plans as submitted or shown on the attached Record of vote: motion to approve made by T Ehinger, seconded by G Wood passed 6-0 In favor: T Ehinger, K Cavotta, K D’Andrea, L DiCarlo, R DuBoff, G Wood Absent: J. Pfeil Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and actual work begun. As a result of this decision, the applicant:  may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent evised 12/2025 APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person: Applicant Owner Attorney/Agent An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - for example: 165.52 – 4 – 37 ) Current Zoning District: Property use: Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRB for this property? No Yes – date(s)? _____________________ App. No.(s)? _________________ Date Acquired by Owner: _________________ HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW FOR OFFICE USE] Application #) Date received) Project Title) Staff Review _______________ No. NM 17/VZ15 SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450) 3. REPLACE SPAN OF NEUTRAL TO P18 1MTH 250' OF 1/0 TPX. 4. ATTACH TPX AT 31'6". 5. REPLACE SEC BRACKETS (NG 10-101 FIG 5). 6. REPLACE PRI DG (NG 3-105). 7, INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. LICENSE APPLICATION BROOD & RIDDLE/MDG:5000993724 WORK REQUEST ##30352102 t F 4 ...• I• ti z • 1 EXISTING POLE PHOTO C-2A SCALE: NTS EXISTING PRIMARY ELECTRIC 34.0'± AGL \ TOP OF EXISTING UTILITY POLE 33.2'± AGL EXISTING PRIMARY ELECTRIC 31.3'± AGL EXISTING DOWN GUY WIRE IX 30.0'± AGL EXISTING PRIMARY ELECTRIC LINE TO BE RELOCATED PER NATIONAL GRID REQUIREMENTS SEE 3/C-2A) EXISTING PRIMARY ELECTRIC CROSSARM TO BE REMOVED & REPLACED PER NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) R_ EXISTING SECONDARY ELECTRIC LINE TO BE RELOCATED PER f NATIONAL GRID REQUIREMENTS EXISTING SECONDARY SEE 3/C-2A) 26.3'± AGL EXISTING DOWN GUY TO BE REMOVED & REPLACED EXISTING COMM LINE TO BE r1h EXISTING FIBER LINE RELOCATED (BY OTHERS) 22.7 ± AGL EXISTING DOWN GUY WIRE EXISTING COMM LINE TO BE 22.7'± AGL RELOCATED (BY OTHERS) EXISTING COMM LINE 22.0'± AGL EXISTING UTILITY POLE NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE STREET SIDE 2 EXISTING UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (22x34 SIZE) 19" TOP OF PROPOSED UTILITY POLE REPLACE PRIMARY 38.5 ± AGL / CROSSARM WITH NG 9-450 RELOCATED PRIMARY 36.5'± AGL- NEW/REPLACEMENT DOWN GUY WIRE 35.2'± AGL NEW REPLACEMENT SECONDARY 31.5'± AGL RELOCATED FIBER LINE MR-) 25.0'± AGL r rik RELOCATED DOWN GUY WIRE % 25.0'± AGL 0RELOCATED COMM LINE 24.0 ± AGL REPLACE PRI DG (NG 3-105). INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE REPLACE SPAN OF NEUTRAL TO P18 WITH 250' OF 1/0 TPX. ATTACH TPX AT 31'6". REPLACE SEC BRACKETS (NG 10-101 FIG 5) COMM/FIBER REATTACHMENTS TO BE DONE BY OTHERS (BY OTHERS) EXISTING UTILITY POLE NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE i STREET SIDE 3 PROPOSED UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (2204 SIZE) verizon 1 175 CALKINS ROAD ROCHESTER, NY 14623 la Tectonic FRACMAL sousnmca. Tat* m EmOw" Co mAmts, Codogisr i lad Uwwp s, Q.P.C. Proj. ? Gamut Info 36 British Amorleon Blva. Phor: (518) 783-1G3.9 Suiv te 101 800 829-6531 Latham. NY 12110 www.to&-onicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP Alf% r% ATC ICCIIC 0 05/ 06/26 FOR REGULATORY 1 06/ 09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIGINAL SIZE IN INCHES 22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES 11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 MAKE READY SCOPE OF WORK C- 2A