HomeMy WebLinkAbout20260793 Henning Rd Verizon Utility Pole Modification NOD
Page 1 of 1
Tamie Ehinger, Chair
Rob DuBoff, Vice Chair
Karen Cavotta
Karen D’Andrea
Leslie DiCarlo
Jeff Pfeil
Geoff Wood
Alison Dockum, Alternate
Christina Abele, Alternate
CITY OF SARATOGA SPRINGS
D ESIGN R EVIEW B OARD
❖
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x.2517
www.saratoga-springs.org
NOTICE OF DECISION
In the matter of the application
#20260793
Henning Road Verizon Utility Pole-Modification
Henning Road
Saratoga Springs, New York 12866
involving Architectural review of a modification to an approved application for the collocation of a utility pole and wireless
equipment in the right of way within the Rural Residential (RR) District, within the City of Saratoga Springs.
In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:
Type II action – exempt from further SEQR review
And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance
Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the
following decision on September 23, 2026:
Approve the plans as submitted or shown on the attached
Record of vote:
motion to approve made by T Ehinger, seconded by G Wood passed 6-0
In favor: T Ehinger, K Cavotta, K D’Andrea, L DiCarlo, R DuBoff, G Wood
Absent: J. Pfeil
Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and
actual work begun.
As a result of this decision, the applicant:
may proceed with the proposed project as approved
Please contact the Building Department to verify permit requirements.
Chair Received by Accounts
cc: Building Department
Accounts Dept.
Applicant/Agent
evised 12/2025
APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT
Name
Address
Phone / / /
Email
Identify primary contact person: Applicant Owner Attorney/Agent
An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question.
Applicant’s interest in premises: Owner Lessee Under option to lease or purchase
PROPERTY INFORMATION
Property Address/Location: Tax Parcel #: . - -
for example: 165.52 – 4 – 37 )
Current Zoning District: Property use: Residential Non-residential/mixed-use
Type of Review: Architectural Historic Extension/modification (of current approval)
Summary description of proposed action:
Has a previous application been filed with the DRB for this property? No Yes – date(s)? _____________________
App. No.(s)? _________________
Date Acquired by Owner: _________________
HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED**
CITY OF SARATOGA SPRINGS
DESIGN REVIEW BOARD
CITY HALL - 474 BROADWAY
SARATOGA SPRINGS, NEW YORK 12866-2296
TEL: 518-587-3550 X2533
www.saratoga-springs.org
APPLICATION FOR:
ARCHITECTURAL / HISTORIC REVIEW
FOR OFFICE USE]
Application #)
Date received)
Project Title)
Staff Review _______________
No. NM 17/VZ15
SUMMARY OF MAKE READY WORK
1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC
MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS.
2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH
TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450)
3. REPLACE SPAN OF NEUTRAL TO P18 1MTH 250' OF 1/0 TPX.
4. ATTACH TPX AT 31'6".
5. REPLACE SEC BRACKETS (NG 10-101 FIG 5).
6. REPLACE PRI DG (NG 3-105).
7, INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE.
NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK.
CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION
STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT
SPECIFICATIONS.
LICENSE APPLICATION BROOD & RIDDLE/MDG:5000993724
WORK REQUEST ##30352102
t
F 4 ...•
I•
ti
z •
1 EXISTING POLE PHOTO
C-2A
SCALE: NTS
EXISTING PRIMARY ELECTRIC
34.0'± AGL \
TOP OF EXISTING UTILITY POLE
33.2'± AGL
EXISTING PRIMARY ELECTRIC
31.3'± AGL
EXISTING DOWN GUY WIRE
IX
30.0'± AGL
EXISTING PRIMARY ELECTRIC
LINE TO BE RELOCATED PER
NATIONAL GRID REQUIREMENTS
SEE 3/C-2A)
EXISTING PRIMARY ELECTRIC
CROSSARM TO BE REMOVED &
REPLACED PER NATIONAL GRID
REQUIREMENTS (SEE 3/C-2A)
R_
EXISTING SECONDARY ELECTRIC
LINE TO BE RELOCATED PER
f
NATIONAL GRID REQUIREMENTS
EXISTING SECONDARY SEE 3/C-2A)
26.3'± AGL
EXISTING DOWN GUY TO
BE REMOVED & REPLACED
EXISTING COMM LINE TO BE
r1h EXISTING FIBER LINE
RELOCATED (BY OTHERS)
22.7 ± AGL
EXISTING DOWN GUY WIRE
EXISTING COMM LINE TO BE
22.7'± AGL RELOCATED (BY OTHERS)
EXISTING COMM LINE
22.0'± AGL
EXISTING UTILITY POLE
NM 17 /VZ 15 TO BE
REMOVED & REPLACED
EXISTING GRADE
STREET SIDE
2 EXISTING UTILITY POLE ELEVATION
C-2A
SCALE: 3/16" = 1'—O" (11x17 SIZE)
3/8" = 1'—O" (22x34 SIZE)
19"
TOP OF PROPOSED UTILITY POLE
REPLACE PRIMARY
38.5 ± AGL /
CROSSARM WITH NG 9-450
RELOCATED PRIMARY
36.5'± AGL-
NEW/REPLACEMENT DOWN GUY WIRE
35.2'± AGL
NEW REPLACEMENT SECONDARY
31.5'± AGL
RELOCATED FIBER LINE
MR-) 25.0'± AGL
r
rik RELOCATED DOWN GUY WIRE %
25.0'± AGL
0RELOCATED
COMM LINE
24.0 ± AGL
REPLACE PRI DG (NG 3-105).
INSTALL SEC DG (NG 3-118)
CONFIRMED ON EXISTING THIMBLE
REPLACE SPAN OF NEUTRAL TO
P18 WITH 250' OF 1/0 TPX.
ATTACH TPX AT 31'6". REPLACE SEC
BRACKETS (NG 10-101 FIG 5)
COMM/FIBER REATTACHMENTS TO
BE DONE BY OTHERS (BY OTHERS)
EXISTING UTILITY POLE
NM 17 /VZ 15 TO BE
REMOVED & REPLACED
EXISTING GRADE
i
STREET SIDE
3 PROPOSED UTILITY POLE ELEVATION
C-2A
SCALE: 3/16" = 1'—O" (11x17 SIZE)
3/8" = 1'—O" (2204 SIZE)
verizon
1
175 CALKINS ROAD
ROCHESTER, NY 14623
la
Tectonic
FRACMAL sousnmca. Tat*
m EmOw" Co mAmts, Codogisr i lad Uwwp s, Q.P.C. Proj. ?
Gamut
Info 36
British Amorleon Blva. Phor: (518) 783-1G3.9 Suiv
te
101
800 829-6531 Latham. NY
12110 www.to&-onicengineering.com WO NUMBER
DRAWN BY REVIEWED BY 12861.115
LP MP Alf% r%
ATC ICCIIC 0 05/
06/26 FOR REGULATORY 1 06/
09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION
OR ADDITIONS TO A PLAN BEARING THE
SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS
A VIOLATION OF SECTION 7209 SUBDIVISION 2
OF THE NEW YORK STATE EDUCATION LAW. COPIES
OF
THIS DOCUMENT WITHOUT A FACSIMILE OF THE
SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR
ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL
ENGINEER OR LAND SURVEYOR SHALL NOT
BE CONSIDERED VAUD COPIES. 0 1
ORIGINAL SIZE
IN INCHES 22x34 FORMAT)
0 1
ORIGINAL SIZE
IN INCHES 11x17 FORMAT)
SITE INFORMATION
ROOD & RIDDLE
FUZE ID#:
17612418 MDG#: 5000993724
SITE ADDRESS
UTILITY PO
LE# NM 17/VZ 15 ALONG HENNING
RD CITY OF
SARATOGA SPRINGS SARATOGA COUNTY
NY 12866
MAKE READY
SCOPE OF WORK C-
2A