Loading...
HomeMy WebLinkAbout20260653 1 Kaydeross Ave Reverie 73 Signage NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Karen Cavotta Karen D’Andrea Leslie DiCarlo Jeff Pfeil Geoff Wood Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20260653 1 Kaydeross Ave Reverie 73 Signage 1 Kaydeross Ave. Saratoga Springs, New York 12866 involving Architectural review of illuminated monument signage within the Gateway Rural Commercial (GC-R) District, tax parcel #191.-2-26, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240 - 13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on September 9, 2026:  Approve the plans with the following conditions: The green sections of the top part of the sign are to be opaque and the bottom of the sign is to be non- illuminated. Address changes to be submitted for administrative approval. Record of vote: motion to approve made by L DiCarlo, seconded by J Pfeil passed 5-1 In favor: T Ehinger, K D’Andrea, L DiCarlo, J Pfeil, G Wood Opposed: R DuBoff Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and actual work begun. As a result of this decision, the applicant:  may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent DOUBLE SIDED MONUMENT: SCALE: 3/8”=1’-0” 24.7 SQ.FT. (SAME AS EXISTING) D/F ILLUM WHITE CABINET WITH 1.50” RETAINERS FACE: WHITE LEXAN WITH DIGITAL TRANSL PRINT LED IN CABINET: 3000Kelvin LEDs POLE COVERS: WHITE (OVER 10” I-BEAMS) 3” x 3” ALUM TUBE FRAME; WHITE .090” ALUM. SKINS NOTE: SEE FABRICATION AND ATTACHMENT DETAILS ON PAGE 2 CUT VINYL ADDRESS NUMBER FACE-LIT CHANNEL CELLS (QTY: 2) FACES: WHT LEXAN TRIMLESS RETURNS: 3” DEEP WHITE WHITE LED LIGHTING:3000Kelvin LEDs MTD FLUSH B 2 11.frame details 8/19/26 2-r11 15" 15 1/2" 12" 40" 2 3/16"3" 2” x 2” tube frame cap, .090” alum. faces; attaches down to lower tube frame using tamper-resistant at head screws; removable for access to lower face screws Dibond or similar LED carriers, both sides 1-1/4” x 1-1/4” x 1/8” cabinet frame, skinned with 1/8” alum., sides, and bottom, top panel removable for access inside 040” aluminum sheeting to cover steel beam, white Existing 10” steel beam, approx. 100” tall Power supplies housed in top of sign, accessible via removable top panel, cut o switch where required 22 3/16" 1-1/2” x 1-1/2” x 1/8” alum. angle retainer frame 1/8” alum. face with top and bottom folded anges for attachment to frame; screws accessible when top cap is removed Existing brick wall, to remain 3” deep trimless channel letter “cell” design; 3000K LEDS; attached to frame from inside alum. frame face 48" 22" 43 7/8" 89" 65 5/8" 24 5/8"10 1/8"6 1/2" 21 3/4" 43 1/2" 65 1/4" 89" Cabinet installs from inside through to steel beams using 3/8”-16 hardware 3/16” thick lexan face with translucent vinyl applied Central support tubes/attachment points for LED dibond carriers 22 1/2" 1/4”-20 hardware into brick anchors 3” x 3” x 1/8” alum. vertical tube supports 2” x 2” x 1/4” alum. angle welded to frame for attachment to brick 3” x 3” x 1/8” alum. mitered tube frame Power supply mounted inside sign 63 1/2" 12" 11.frame details 8/19/26 2-r11 FRONT FRAME VIEW 3/4” =1’-0” A SIDE SECTION 3/4” =1’-0” B