Loading...
HomeMy WebLinkAbout20260800 172 Caroline St Construction Application"HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED" CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)" OWNER(S) (llnotapplicant) Name Rick & Jodi Romero SAME Address 172 Caroline Street Saratoga Springs, N.Y. 12866 Phone 602-524-3554 Email Identify primary contact person: ❑ Applicant ❑ Owner IN Attorney/Agent [FOR OFFICE USEI (Application #) (Date received) (Project Title) Staff Review ATTORNEY/AGENT Robert L. Flansburg 6 Meghan Court Saratoga Springs, N.Y. 12866 518-935-3285 / 4 An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: PROPERTY INFORMATION W Owner ❑ Lessee Property Address/Location: 172 Caroline Street Date Acquired by Owner: 3/10/26 ❑ Under option to lease or purchase Tax Parcel #: 166 61 1 7 (!or example: 16552 — 4 — 37) Current Zoning District: UR-3 Property use: © Residential ❑ Non-residential/mixed-use Type of Review: ❑ Architectural © Historic ❑ Extension/modification (of current approval) Summary description of proposed action: Applicants wish to add a rear porch to the home to match the front porch in composition. They desire to connect the newly relocated garage tote huime via a small -c-o—ve—re-cl walkway o t e —proposed rear porch. Has a previous application been filed with the DRB for this property? ❑ No ® Yes - date(s)? multiple App. No.(s)? 20240457 Revised 12/2025 **A "complete" application consists of 1 hard copy (original) and I electronic copy of application &ALL other materials as required below: New Construction / Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. ❑ Elevation drawings showing design of all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Floor plans for proposed structure; on sheet no larger than 2'x3' — smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Within front yard setbacks In Historic Districts Only (Front setbacks: UR-I & INST-HTR=30'; UR-4=25'; UR-2, UR-3 & NCUD-1=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2'x3' sheet — smaller preferred if legible ❑ Product literature, specifications and samples of proposed materials and colors Signage / Awnings ❑ Color photographs showing site/exterior details of existing structures, and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I "xi 7" ❑ Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location ❑ Product literature, specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of "architectural/historical significance", demonstrate "good cause" why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing" structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale ❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 12/2025 Request for extension of current approval ❑ Identify date of original DRB approval: Current expiration date: Org. App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the Uneighborhood. SE Environmental Assessment Form ❑ Applicants proposing the following must complete "Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.5!ov/docs/`permits ei operations Pdf/seafpartone 0 : - Construction or expansion of a multi -family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? ® No ❑ Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification /we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Board. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Further I/ agre meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review o Z ing C of the City Springs. 8/28/26 Date: (applicant signature) (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Owner Signature: Date: Revised 12/2025 T 2'-2" 4'-10" 22'-4" M O O a W N m 1 N EXISTING HOUSE =L -8 COVERED Q FRONT c0 PORCH 0; ;& 2'-4" 1'-10" 3'-O" I'-10" 2'-4" --------------- --------------- 6'-2'i-z" I: -I" 2'-4" 6'4' 2'-4" 25'-0" FIRST FLOOR PLAN SCALE: 1/4% f-O" ri m 22'-` 11 �I-011 10�-4" 0 -011 la 11'-2" EXISTING GARAGE FLAN SGALE: 1/2" X V-O" TOP OF PLATE TOP OF WINDOW _P = Q Q SUBFLOOR TOP OF PLATE TOP OF WINDOW m Q r SUBFLOOR TOP OF FDN. TOP OF PLATE TOP OF WINDOW � Q Q BUBFLOOR iOP OF PLATE TOP OF WINDOW m Q �a r SUBFLOOR iOP OF FDN. REAR ELEVATION - EXISTING SCALE: 1/4"= 1'-0" FRONT ELEVATION - EXISTING SCALE: 1/4% I'-O" TOP OF PLATE fOP OF WINDOW _7 Q Q SUBFLOOR TOP OF PLATE G OF WINDOW Q Q! �a SUBFLOOR r TOP OF FDN. TOP OF PLATE 'OP OF WINDOW Q ! s SUBFLOOR TOP OF PLATE 'OP OF WINDOW Q Q� SUBFLOOR r OP OF FDN TOP OF LL m Q s �a r BUBFLc iOP OF FDN. iOP OF PL TOP OF WINI Q s SUBFLOC TOP OF PL41 TOP OF WIN Q! Q aTa IT SUBFLOOI TOP OF FDN. LEFT ELEVATION - EXISTING SCALE: 1/4% f-O" RIGHT ELEVATION - EXISTING BCALE: 1/4% f-O" OF PLATE OF WINDOW Q Q BFLOOR W OF PLATE OF WINDOW Q Q! �a 1BFLOOR r iOP OF FDN. OF PLATE DF WINDOW Q s !FLOOR P OF PLATE- — JF WINDOW Q 6� �a BFLooR r TOP OF FDN NEW Describe edits or ask questions 0 Q Edit Comment Resize PROPOSED REAR ELEVATION PROPOSED FRONT ELEVATION �1 FROF06ED LEFT ELEVATION 22'-4" 4' 'W x TIMBEf (T"rf=.) 4' 'W X TIMBEf (TYf .) 5' -5 11 W -roll V -5 11 NEW FIR&T FLOOR PLAN - GARAGE 9, SCALE: 1/4" = 1'-O" 22'-` 11 At In i i N ' N Q S? N N N T t �4 T CV MD _ -1'-211 Si_OII -ti-211 ------------------- ---- ----- F-7 16'-O3/q�� ---- ----- g ii o /q, EXISTING 2X4 EXTERIOR WALLS - ---- ----- - TO BE FIRRED OUT N - m - - - - ---- - - - _ - ---- _ - TO BE 2X6 IUALLS (TYF'.) r m 6� 0� N �� 5EDROOI" I - - Q- N------------ 2'-ro KITCHE (V \ LIVING AP _ Room � � 61 m (NEW 8' CEILING I-IEIGPT) m m r -t'-2lip FRIDCx '-211 � Q cv ------------------- o�m�� 1'-2%2" 1'-2�/:211 -'-2n 8'-Oii -V-2ii 22'-4" NEW SECOND FLOOD' FLAN - GAIRA E SCALE: 1/4" = 1'-O" EXISTING SECONI OR WINDOWS WILL REPLACED WITH I PELLA ALUMINUM iD WINDOWS WITH - TOP OF PLATE TOP OF WINDOW r SURF TOP 0 ol TOP AO ROOFINGALL SIDING, AND EXTERIOR TRIM ■n`MATERIALS TO MATCH inmm■um� \ . - ■�■m■m■m ��■i ■n■n��n■ nn in■m■m■n�■ �■� ■mm�mn■nn �■i ■�■m■m■m■n ■m■m■mimm ■■n■■ol■�■n■ ALL EXISTING SECONI FLOOR WINDOWS WILL BE REPLACED WITH NEW FELLA ALUMINUM CLAD WINDOWS WITH F PLATE SOL MUNTINS OF WINDOW PROPOSED WOODEN STAIRCASE AND STAIR RAILING I X 2 WOODEN BALLUSTERS _ i 3FLOOR (h OF PLATE *09ED 4'O" X 4'O" X6" JEN SUPPORT BRACKETS - - - - - - OTAIRB 4 LANDING ABOVE - - - - - - TOP OF SLAB RIGHT ELEVATION SCALE: 1/4 FRONT ELEVATION SCALE: 1/4% 1'-0" �ry TC NOTE: ALL SIDING AND ROOFING TO BE REPLACED IN KIND, MATERIALS TO MATCH EXISTING. TOP O TOP N = r � t" TC NOTE: ALL SIDING AND ROOFING TO BE REPLACED IN KIND, MATERIALS TO MATCH EXISTING. TOP O TOP N = r � t" JOVERHEAD Q RAGE DOOR BE INSTALLED DDUCT DETAIL 7TOP , TOP SCALE: 22'-8" REAR ELEVATION SCALE: 1/4% 1'-0" 31--l" 2'-2" 12,-111, 22'-4" EXISTING ENTRY 2'-2" TO BE REMOVED F OM THIS OOATION 3.--T.. 1 -4 !o 12,-0 22'-4" NEW NEI D- IN PLACE COVERED F EXISTING I -P JP ri EXISTING HOUSE +4� FRONT COVERED PORGH :(D:. 2'-4" 1'-1011. 3'-0" 2-1" &'-0 11'-2" ql,-I" 1 1 2'-4" 1 2-l" 25--0-- PROPOSED FLOOR FLAN SCALE: li4 =-', ALL RAILING6. LATTICE AND C TO MATCH EXIf FRONT PORCH REAR PORCH PROPOSED REAR ELEVATION SCALE: 1/4 I'-O" REAR PORCH PROPOSED LEFT ELEVATION SCALE: 1/4"= f-O" PLATE WINDOW 0 0 _OOR OF PLATE ' WINDOW Q� �a 'LOOK r 70P OF FDN.