Loading...
HomeMy WebLinkAbout20260793 Henning Rd Verizon Utility Pole Modification Application ATTORNEYS AT LAW _______________ MAIN OFFICE (FOR ALL MAIL): 500 FEDERAL STREET, 5TH FLOOR, TROY, NEW YORK 12180 ALBANY OFFICE: 41 STATE STREET, STE 604-12, ALBANY, NEW YORK 12207 _______________ Phone: 518-438-9907 • Fax: 518-438-9914 _______________ www.youngsommer.com David C. Brennan, Esq. Writer’s Telephone Extension: 224 dbrennan@youngsommer.com September 4, 2026 Via Federal Express Mark Graham Administrative Assistant for OPED City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866 RE: Cellco Partnership d/b/a Verizon Wireless Application for Amended DRB Approval - Utility Pole No. NM 17/VZ 15 – Along Henning Rd. Dear Mr. Graham: Please find enclosed an application to the Design Review Board for a modified proposal to add a wireless small cell antenna and equipment to a replacement utility pole in the public right of way. This application was approved by the Design Review Board on July 22, 2026. The applicant is seeking to have this approval amended to reflect an increase in pole height. Please find the enclosed materials: 1. An Application for Amendment of Current Approval to the Design Review Board; 2. A Copy of the Notice of Decision Issued by the Design Review Board; 3. Updated SEQRA Short EAF; and 4. Updated Project Zoning Drawings Also enclosed is a check in the amount of $325.00 for the application fee. The purpose of this amended application is to increase the height of the replacement utility pole from the approved height of 38.5 ft. with an antenna tip height at 41.7 ft. to a revised utility pole height of 43.0 ft. with an antenna tip height at 46.2 ft. Utility poles come in standard five- foot increments, and the change represents use of the next taller pole size, with a burial depth of 10% of pole height plus 2 ft. This requirement is necessitated by National Grid requirements. National Grid proposed the 38.5 ft pole but subsequently revised its proposal to reflect its system needs and requirements. As National Grid owns and controls the infrastructure, Verizon is constrained to accept its requirements in order to collocate on the utility company’s infrastructure. We look forward to discussing this further with the Design Review Board at an upcoming meeting. In the meantime, if you have any questions concerning this letter or the enclosed materials, please contact me at your convenience. Very truly yours, David C. Brennan, Esq. Encl. DESIGN REVIEW BOARD CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, NEW YORK In the Matter of the Application of ______________________________________________________________ CELLCO PARTNERSHIP d/b/a Verizon Wireless Utility Pole No. NM 17/VZ 15 Along Henning Rd., Saratoga Springs, New York 12866 ____________________________________________________________ APPLICATION FOR DESIGN REVIEW BOARD APPROVAL and STATEMENT OF INTENT Submitted by: Verizon Wireless Kathy Pomponio – Network Real Estate 175 Calkins Rd Rochester, New York 14623 (585) 321-5365 Tectonic Engineering & Surveying Consultants, P.C. Steven Matthews, P.E. 36 British American Blvd, Suite 101 Latham, New York 12110 (518) 783-1630 Airosmith Development Inc. Sara Colman, Site Acquisition Specialist 318 West Ave. Saratoga Springs, NY 12866 (518) 461-7114 Please Direct All Correspondence To: Young/Sommer LLC David C. Brennan, Esq. 500 Federal Street, 5th Floor Troy NY, 12180 (518) 438-9907 Dated: September 4, 2026 Revised 12/2025 APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRB for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ No. NM 17/VZ15 **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 12/2025 Revised 12/2025 Request for extension of current approval Identify date of original DRB approval: ______________Current expiration date: ________________ Org. App. No. ____________ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure (4 units +) -Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? No  Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Board. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Revised 12/2025 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Board for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRB will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Board will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Board may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/ quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Board responsibilities may be found in the City’s Unified Development Ordinance available in City Hall and on the City’s web site at https://ny-saratogasprings.civicplus.com/DocumentCenter/ View/17803/Full-UDO Revised 12/2025 City of Saratoga Springs OFFICE OF PLANNING AND ECONOMIC DEVELOPMENT FEES - 2026 Application to City Council FEE Comprehensive Plan Amendment Zoning Ordinance Amendment Planned Unit Development (PUD) Amendment $1,800 + $300/acre $800 + $300/acre $800 + $300/acre Application to Zoning Board of Appeals FEE Use Variance $1,400 + $75/app Area Variance - Residential (1 & 2 Family) $350/1st var + $75/app + $150/ea add variance Area Variance - 3+ Family and Commercial $1,000/1st var + $75/app + $200/ea add variance Interpretations $650 + $75/app Post Work Application Fee Application Fee x2 + $75/app Variance Extensions 50% of Application Fee + $75/app Application to Design Review Board FEE Demolition Residential Structures - 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $500 $75 Façade Change - removal/addition of windows, doors, $150 Addition or new construction $300 Approval Extension 50% of application fee 3+/Multi-Family, Comm, Mixed-Use Principal or Accessory Structure Materials Change - roof, windows, siding, paint color $150 Façade Change - removal/addition of windows, doors, $150 Addition or new construction $650 Approval Extension 50% of application fee Post Work Application Fee Application Fee x2 Application to Planning Board Special Use Permit $1,200 + $75/app Temporary Use Permit $500 Special Use Permit - Extension $400 Special Use Permit - Modification $550 + $75/app Site Plan Review - incl. PUD Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non-Residential / Mixed-use $800 + $150/1,000 sf (Non-Res) + 250 unit (Res) Administrative SPR Residential $400 Non-Residential / Mixed-use $800 Extension Residential $250 Non-Residential / Mixed-use $350 Subdivision - incl. PUD Sketch Plan $400 per sketch Preliminary Approval Residential: 1-5 Lots $700 + $75/app Residential: 6-10 Lots $1,100 + $75/app Residential: 11-20 Lots $1,450 + $75/app Residential: 21+ Lots $1,800 + $75/app Residential - Extension $350 Final Approval Residential $1,550 + $200/lot + $75/app Non-Residential $2,400/lot + $75/app Final Approval Modification Residential $400 + $75/app Non-Residential $800 + $75/app Final Approval Extension Residential $250 Non-Residential $350 * Subdivisions and Site Plans are subject to Engineering Review- See DPW Fees Demolition $500 Residential Structures – 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $75 Façade Change - removal/addition of windows, doors, porch $150 Addition or new construction $300 Approval Extension 50% of Application Fee 3+/Multi-Family, Comm, Mixed-Use Principal or Accessory Structure Equipment Install or Materials Change - roof, windows, siding, paint color $150 Signs, awnings $150 Façade Change - removal/addition of windows, doors, porch $300 Addition or new construction $650 Approval Extension or Modification 50% of Application Fee Post Work Application Fee Application x2 Other Lot Line Adjustment/Subdivision Administrative Action $400 Letter of Credit – Modification Extension $400 Letter of Credit - Collection up to 1% of LoC Recreation Fee $2,000/lot or unit Land Disturbance Activity Permit $750 + $35/acre Watercourse/Wetland Permit $750 Watercourse/Wetland Permit Extension $350 SEQRA EIS Review (Draft & Final) TBD Sidewalk Fee Lieu See DPW Fees Tree Removal Avg. nursery cost in caliper of new species equivalent to diameter at breat height (DBH of tree(s) Removed diameter at breat height (DBH of tree(s) Removed Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Karen Cavotta Karen D’Andrea Leslie DiCarlo Jeff Pfeil Geoff Wood Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application 20260521 Henning Road Verizon Utility Pole Adj to Henning Road Saratoga Springs, New York 12866 involving Architectural review of collocation of a utility pole and wireless equipment in the right of way within the Rural Residential (RR) District, tax parcel #166.61-3-25, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR: Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on July 22, 2026: Approve the plans as submitted or shown on the attached Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and actual work begun. Record of vote: motion to approve made by T Ehinger, seconded by G Wood passed 6-0 In favor: T Ehinger, R DuBoff, K D’Andrea, K Cavotta, J Pfeil, G Wood Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent 13# NORTH ORIENTATION N 7l1. NOR4 H ORIENTATIO'J ESTABL ISId ..0 N BY COMPASS OBSERVATION!. EDGE OF EXISTING—., PAVEMENT IIF1 1` C' O 41 o y. F its r ! A t w M C. Ir 1 EXISTING OVERHEAD WIRE (TYP) d .. . yf) # / t + C' PROPOSED VERIZON WIRELESS EQUIPMENT ON PROPOSED UTILITY POLE. NEW POLE TO \ t REPLACE EXISTING UTILITY POLE #NM 17/VZ 15 \ 1 e r s ir; do ` — EKSTI Nt U11LITY POLE `TIP) R NOTE: SITE IN- ORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING CONSULTANTS, GEOLOGISTS & LAND SURVEYORS D.P.C., OIJ 11 /10/25. 1 SITE PLAN 1" - 8"" (11x17 S12E) 1- = 40' (22x34 S17E) EXISTING UTILITY POLE TO BE REMOVED & REPLACED EQUIPMENT PLAN C-1 SCALE: 3/4' = 1•-0" (11x17 SIZE) 1 1/2" - (22x34 SIZE) PROPOSED VERIZON WIRELESS EQUIPMENT SHROUD WITH PROPOSED RRH AND ASSOCIATED EQUIPMENT SEE DETAIL 5/C-3) PROPOSED FUJITSU PASSIVE - FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD PROPOSED VERIZON WIRELESS 1" FIBER CONDUIT PROPOSED 1-1/2" CONDUIT FROM SECONDARY TO METER) PROPOSED UTILITY POLE 3 SHROUD PLAN VIEW SCALE; 3/4" = 1'-0" ('tx,7 SIZE) 1-1/2" = 1•-0" (22x34 SIZE) PROPOSED #2 VERTICAL GROUND 1-1 /2" FROM RY TO METER) PROPOSED METER PROPOSED #2 VERTICAL GROUND PROPOSED 100A LOAD CENTER DPOSED 1-1 /4" RISER FOR AC C`I IITq Tn gHRni In GUARD FOR ANTENNA verizon 175 CALKINS ROAD 11 ROCHESTER, NY 14623 Tectonic PRAC"i SOMC . Te,_tone E4%MWA0ComAwta, 090bolb ! Land %-wtom, "-.- Project ca":-tact Into 36 8r-tlwh Amerizon BlvC Phorn. '5'8) 7,43-1630 SJ;te 10' {900) 82.9-6531 Latnam, NY 12110 »wwAezt3mcengincerngxom NO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP kin 11A= ICCI IC 0 05/G6/26 FOR REGULATORY 1 05/D9/26 ADDED PAINT NOTE pF A` j UNAUTHORIZED AL =RATION CR ADDITIONS TO A PLAN: BLARING THE SEAL OF A LICENSED ENGINEER OR LAP:D SURVEYOR IS A VIOLATION OF SECTION 7209 SUED - VISION 2 OF THE NEW YORK STATE EDUCATION u.w. COPIES OF THIS DOCUMEN' VlrTHOUT A FACSIMILE 0= THE SIGriATLRE AND AN: ORIGINAL EMBOSSED SEAL OR OR;GINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR L-.'JD SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES- 0 1 ORIGINAL SIZE IN INCHES 22x34 FORMAT) 0 ORIGINAL SIZE IN INCHES 11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE IDS: 17612418 MDG#: 5000993724 511E ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE SITE PLAN & EQUIPMENT PLAN SHEET NUMBER Cw l SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450) 3. REPLACE SPAN OF NEUTRAL TO P18 1MTH 250' OF 1/0 TPX. 4. ATTACH TPX AT 31'6". 5. REPLACE SEC BRACKETS (NG 10-101 FIG 5). 6. REPLACE PRI DG (NG 3-105). 7, INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. LICENSE APPLICATION BROOD & RIDDLE/MDG:5000993724 WORK REQUEST ##30352102 t F 4 ...• I• ti z • 1 EXISTING POLE PHOTO C-2A SCALE: NTS EXISTING PRIMARY ELECTRIC 34.0'± AGL \ TOP OF EXISTING UTILITY POLE 33.2'± AGL EXISTING PRIMARY ELECTRIC 31.3'± AGL EXISTING DOWN GUY WIRE IX 30.0'± AGL EXISTING PRIMARY ELECTRIC LINE TO BE RELOCATED PER NATIONAL GRID REQUIREMENTS SEE 3/C-2A) EXISTING PRIMARY ELECTRIC CROSSARM TO BE REMOVED & REPLACED PER NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) R_ EXISTING SECONDARY ELECTRIC LINE TO BE RELOCATED PER f NATIONAL GRID REQUIREMENTS EXISTING SECONDARY SEE 3/C-2A) 26.3'± AGL EXISTING DOWN GUY TO BE REMOVED & REPLACED EXISTING COMM LINE TO BE r1h EXISTING FIBER LINE RELOCATED (BY OTHERS) 22.7 ± AGL EXISTING DOWN GUY WIRE EXISTING COMM LINE TO BE 22.7'± AGL RELOCATED (BY OTHERS) EXISTING COMM LINE 22.0'± AGL EXISTING UTILITY POLE NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE STREET SIDE 2 EXISTING UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (22x34 SIZE) 19" TOP OF PROPOSED UTILITY POLE REPLACE PRIMARY 38.5 ± AGL / CROSSARM WITH NG 9-450 RELOCATED PRIMARY 36.5'± AGL- NEW/REPLACEMENT DOWN GUY WIRE 35.2'± AGL NEW REPLACEMENT SECONDARY 31.5'± AGL RELOCATED FIBER LINE MR-) 25.0'± AGL r rik RELOCATED DOWN GUY WIRE % 25.0'± AGL 0RELOCATED COMM LINE 24.0 ± AGL REPLACE PRI DG (NG 3-105). INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE REPLACE SPAN OF NEUTRAL TO P18 WITH 250' OF 1/0 TPX. ATTACH TPX AT 31'6". REPLACE SEC BRACKETS (NG 10-101 FIG 5) COMM/FIBER REATTACHMENTS TO BE DONE BY OTHERS (BY OTHERS) EXISTING UTILITY POLE NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE i STREET SIDE 3 PROPOSED UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (2204 SIZE) verizon 1 175 CALKINS ROAD ROCHESTER, NY 14623 la Tectonic FRACMAL sousnmca. Tat* m EmOw" Co mAmts, Codogisr i lad Uwwp s, Q.P.C. Proj. ? Gamut Info 36 British Amorleon Blva. Phor: (518) 783-1G3.9 Suiv te 101 800 829-6531 Latham. NY 12110 www.to&-onicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP Alf% r% ATC ICCIIC 0 05/ 06/26 FOR REGULATORY 1 06/ 09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIGINAL SIZE IN INCHES 22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES 11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 MAKE READY SCOPE OF WORK C- 2A NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. PROPOSED 4G ANTENNA SEE DETAIL 1 /C-3) PROPOSED POLE TOP ANTENNA MOUNT (SEE DETAIL 1 /C-3) INSTALL RF "CAUTION" SIGNAGE 2't BELOW PROPOSED ANTENNA (SEE DETAIL 4/C-3) PROPOSED WEATHERHEAD FOR POWER CARLON P/N: E99SH-CAR OR APPROVED EQUAL) PROPOSED COAX CABLES TO ANTENNAS IN 4" MAX U-GUARD PROPOSED MOPT TERMINAL - BY OTHERS) PROPOSED LC/UPC BIDI RUGGEDIZED FIBER - JUMPER FROM THE PROPOSED MOPT TERMINAL TO PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE WITHIN 1" CONDUIT PROPOSED VERIZON WIRELESS - EQUIPMENT SHROUD WITH PROPOSED RRH & ASSOCIATED EQUIPMENT COMMSCOPE PN: SSC-760249586X1 X OR EQUAL) (SEE DETAIL 5/C-3) PROPOSED 1-1/4- PVC RISER FOR - AC CIRCUITS TO SHROUD PROPOSED EATON BRP12B10OR LOAD CENTER OR APPROVED EQUAL (SECURE TO POLE USING UNISTRUT OR APPROVED MANUFACTURER RECOMMENDED HARDWARE) PROPOSED RF "INFORMATION" - SIGNAGE (SEE DETAIL 4/C-3) PROPOSED METER MILBANK P/N: U2048-RL OR-/ APPROVED EQUAL (SECURE TO POLE USING ERICKSON SERIES PBAL MOUNTING BRACKET OR ELECTRIC COMPANY APPROVED EQUAL) TOP OF PROPOSED ANTENNA 41.7'f AGL q PROPOSED ANTENNA- ---- --- -- - - 40.7'f AGL TOP OF EXISTING UTILITY POLE 38.5't AGL MIN EXISTING PRIMARY 36,3't AGL EXISTING SECONDARY 31.5'± AGL PROPOSED 1-1 /2" PVC RISER FOR POWER EXISTING GUY %"v'IRE 75.Ci't AGL EXISTING FIBER 25.0't AGL EXISTING C01/IMUNICATION 4.0'+ AGL BOTTOM OF PROPOSED MOPT TERMINAL21.7'f AGL PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD Y2 C-2E BOTTOM OF PROPOSED EQUIPMENT 12.0'f AGL (MINIMUM) BOTTOM OF PROPOSED LOAD CENTER 10.0't AGL (MINIMUM) BOTTOM OF PROPOSED METER 8.0't AGL (MINIMUM) BOTTOM OF PROPOSED RF SIGNAGE 8.0't AGL (MINIMUM) EXISTING UTILITY POLE PROPOSED HIGH IMPACT - PVC CABLE COVER (BLACK) EXISTING G)\ADFi 1 UTILITY POLE ELEVATION 28 SCALE: 3/16" = 1'—u" (11x17 SIZE) 3/8" = V-0" (22 x34 SIZE) EXISTING GRADE 0.0'f AGL PROP( TERMINAL (E PAINTING NOTE: ALL PROPOSED EQUIPMENT SHALL BE PAINTED BROW XISTING FIBER LINE XISTING COMIM LINE POSED VERIZON WIRELESS U-GUARD (CABLES FROM I TO ANTENNA) POSED LC/UPC BIDI RUGGEDIZED R JUMPER FROM THE PROPOSED IT TERMINAL TO PROPOSED FUJITSU 3SIVE FIBER ENCLOSURE POSED VERIZON WIRELESS EQUIPMENT OUD (COMMSCOPE PN: SSC-760249586X1 X EQUAL) (SEE DETAIL 5/C-3) POSED 1-1/2" CONDUIT OM SECONDARY TO METER) OPOSED RUGGEDIZED FIBER JUMPERS TO Hs AND MMUs IN THE SHROUD (TYP OF 2) OPOSED EATON BRP126100R AD CENTER OR APPROVED EQUAL IN OPPOSITE SIDE OF POLE) OPOSED 1-1/2" LIQUIDTIGHT ETER TO LOAD CENTER) PPOSITE SIDE OF POLE) OPOSED METER MILBANK P/N: 048-RL OR APPROVED EQUAL (SECURE POLE USING ERICSSON SERIES PBAL UNTING BRACKET OR APPROVED EQUAL) EXISTING UTILITY POLE ELEVATION DETAIL 2B SCA'_L: 2" = 1'-0" (11x17 SIZE) 1" - 1'—O" (22x34 SIZE) verizon i 75 CALKINS ROAD IitPr)rrESTER, NY 14623 i flectonic AmuL,SOLUTIoR&EXUP"ON LS.RVICE. T.etd E/+okiew10 Cenartw* Gedogletr t Lane 5lrwyon, Q.P.C. rrojsct Cc^loci info 36 bnt%eh American 81vc. Phore- (5'8 783-1G3J S J'te 101 ,800 829-6531 Lulhom. NY 12110 www.tectoricengmeenng.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP P kin MATT Icc11c C 05/06j26 FOR REGULATORY 1 0o/C9/26 ADDED FAINT NOTE UNAUTHORIZED ALTERATION OR ADDIT5ONS TO A PLAIT SEARING THE SEAL OF A LICENSED ENGINEER OR LAND LRVEYOR IS A VIOLA"ION OF SECTION 7205 SUED -VISION 2 OF T-Ic NFiV YORK STATE EDUCATION L' IV, COPIES OF THIS DOCUMEM WITHOUT A FACSIMTF 0= THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR ZED INK OF THE PROFESSIONAL ENGINEER OR L-.ND SURVEYOR. SHALL NOT 3E CONSIDERED V UD COPIES_ 0 1 ORIGINAL SIZE IN INCHES 22x34 FORIVAT) 0 ORIGINAL SIZE IN INCHES 11 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE POLE ELEVATION & DETAIL SHEET NUMBER ANTENNA (JMA P/N: CX160M1236—BF22) IA MOUNT SLEEVE (GIMBAL) ALFAB P/N: 900070) OLE MOUNT BRACKET CONCEALFAB P/N: 007951 R APPROVED EQUAL) TILITY POLE 0 TO tJE VERIFIED IN FIELD POLE —TOP ANTENNA MOUNTING 3 SCALE: %T3 I` A CAUTION A Transmitting Antenna(s) Radio frequency fields beyond this point MAY EXCEED the FCC Occupational exposure limit. Obey all posted signs and site guidelines. Call Verizon at 1-800-264-6620 PRIOR to working beyond this point. Site ID/ PSLC: verizon •` ACTIVE COMMUNICATION EQUIPMENT u1+JIUYAPR0004t W74i M FT FfOtR2r31iTJILA>tD R V1ERTtf,•1 POMP VON%AkT[hM BY VT7<AM DWOWOMT MTR} OR CALL v [ Iambi V nRE'. E 55 rOR PMR a•aTT001M V44E EVERAPPROACHW# TrViA1ao" _rt 1lOKITIUTALAtq-FT VUMCAI PIAAK CA- L tEF. Z0M WI R 3 S FT 1-I114l- 4QG FRl01l To CFfrtSTlr,G : C _hVEGT :'C- NOTE: 1. CONTRACTOR TO FURNISH AND INSTALL PHENOLIC LABEL APPLIED TO LOAD CENTER. 2. ATTACH R:Y "CAUTION" AND "INFORMATION" SIGNAGE TO FACE OF UTILITY POLE USING 1' r WOOD SCREWS. 3. RF SIGNS ARE APPROXIMATELY 6"0.5" IN SIZE. PROPOSED SIGNAGE SCALE: NTS POLE MOUNTING BRACKET — ERICKSON P/N: PBAL-12 OR APPROVED EQUAL) (TYP OF 2) e r -mil p 1p- 1 /4%1" WOOD SCREW TYP OF 4/BRACKET) S.S. 1/4"-2Ox3/4" CARRIAGE BOLT, FLAT WASHER, & NYLON LOCK NUT INCLUDED WITH BRACKET) PROPOSED METER SOCKET, MILBANK P/N/ U2048—RL (OR APPROVED EQUAL CONFORMING TO UTILITY COMPANY STANDARDS) METER MOUNTING DETAIL C-3 SCALE: NTS Metro Cell Solutions COMMSC- PE SSC-760249586X1X MV2 Micro Radio Concealment Enclosure Universal Single Part Number Radio Enclosure Introduction One pale mou led Ratio Er c i . - •, re fr r a U ywr radio moons under a siroE Dan r, UiTlt er Hpfty contigurabde - swports varyrng conrigurations with a unhwwl mounting t solution Aesftlicaa0F awwad trout ` r. Accepts Rados Iron: • Ericssw radios SSC-760249586EIX Nokia radios SSC-760249586N i X Samsung ra(hos SSC-760249586S 1 X Th= raoic __. ceairrler! e :cf^_ silplsu-e 1= deed to coriia +ea! smaj: cell -e ni " Jr-Te'd 10 wisl 1A MCiiJ) LOT..(C:C. i)1)., iS'_ _ Ili Al. --tJ'CS 81i wd ai vale replan ernerlts wrterc ,; _ :il Impact tt desired- UniQue, ant-.emaI internal rr•wunting s-,s,em Can he k;tted with Rec6-5erz CorrrnScoCe diF.wexers and jumpers System Dimensioning & Configuration i•__ ..-.- n-! -.!..i-. -iti •=i. ll«'".. :-rtr-, •tJ jr .i.;F. ri+i;,i .._ , .C.. :.. its•. 1+._'; ._ i- 1041b f43_+]I with rip fifdC efx:,QFMrY. ,-'I•.; S;:t--, ;`.,i'4 Approx 479tt 1276kgliciytoeded' (maxi weipW vaned on oofilguraeon LAn. ,, Max f..:,ilrCattle Poia 00 2.5ira85 in 00 by ciarnIpr4 (Lwgrr dionew pales by steell bardtng) Mth het ded MWr&V kt) Up to 121n DID Wood Ada with irm:Jitded 511l- ftreaded rod for ttr k* booing UV-resntao powder eoaL Vanouc eako o0o is a, ailae!a Finish 'I- for Ligm Gary. -Y for Green -3- for 84m*, --C for Brown W fcw Fa)rfax Brown -F Federal Park Brown. 'T for hietaa"c SNw "W for W hte Bik-A 1-2) 2' Trade Sire Knockouts Paver: Fiber input Corduii Bat: (2) I Trade Saa KnockocRs Top: (2 ) 2' Trade Size Knockouts MC-SP-RENT-21-001-M NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. UTILITY POLE - r'rCUt-UJ V Ghi t UN Dlzr- I LE ELECTRIC PANEL OR APPROVED E PROPOSED 1 /4%20 3/4" LONG BOLT (TYP OF 3) PROPOSED P1000T — UNISTRUT 6" LONG TYP OF 2) PROPOSED 1 CHANNEL NUT (TYF PROPOSE[ L 3 LOAD CENTER MOUNTING DETAIL SCALE: 4- = 1'-0" (11x17 SIZE) 1•-0" (22x34 SIZE) Metro Cell Solutions COMMSC,. PE Ericaeon CordiOurations 2) RRU1 VRRU!32R212s44154s2&4478 b (i) PSU AC OZW unim 118843 or 4449 Dual Band RRU 6 t2) PSU AC 02'Oa units 1) 9843 and (1) 4478 & (3) PSU AC 02V units 1) 4415_ (1) 444{1 wid (1) 220%440x i (3) PSU AC 02'DB units 1) 4455 and (1) •44413 d. 4 3) PSU AC 02.1% :slits 1) 4440 and (2) 220x-440s 8121 PSU AC 0204 Lauts Up to (61 Zn&K22052206 or 4402 440B radios 1) 4415 or 4426 radea and (1) 220x$440x a (1) PSU AC 02i08 I'Li tine Corrtpatibiltty for plot 320W C-Band Radio '• 11 r 8863 a--.J I 1 I cN S-. a•r 11) 444y (4 ) PSU ACO8,11) (1) :SOX 19=-43 811) Raycap se "PTease e Ccrrtnscgpe for additionaf wriigurabom - sa--m Co"Norrad— 01 or (2) 70Q'1l50 32M oval bard radio. t 1 r RT4401-48A CBRS radio. (1) RT2201- 46r1 LAA rA io, 0 l c1r (2b Dots 2 dk W DC rectifier. (1) SOX 1 o2f Q4W SDx 1426T-43 and (1) Raycep e 11) AWS+PCS AWS.'PCs 32OW dual band rode 11) RT4441.4aA CBRS radio. 01 RT2201j46A LAA radio, (1) Debts 2.0kW DC rectifier, (1) SOX11i260-43r SDX1926T- 43 and (1) Rsycao 111 AWS-PCS or 7W.'85O 32OW duo ber-4 radio. 0116OW dual band radio (1) RT4401-48A CBRS radio. (1) RT2201-46A LAA radio. (1) or (21 Deu 20kW DC Racko, Cow"Itibil-dy rtcilf w. t t l SDX 1926U-43r SDX192UT-43 arxi 11) Raycap SSC-760249S86XIX . 11) or (2) 16OW dual band ratbm (1) RT4401-46A CBRS radio. (1) RT-701 -6A LAA todlo. (1) or iZ) Deka 2.OkW DC rechW (1) 9DX 19260-4N SDX 1926T-4 3 t 1 ! Rayow PifCa-4ns--qr1r, rrprrsar AhV roradxfirtr:ar CO 5gnf ildOf s- Nokia Coefiprodons 14) A scale Micro rziaim 12) Dual Band Radios- 7&)VV and 320W phis tschfws S, upporfeddual band radios. AHFiA " AHFIS "AHFIC '-AHLBA "AP48C.A "AHRCC "Al4 BBA supported Rectifiers, Dolts " GE "CCI "Ndur FPAE Pk; arrtr see Cormrrscnpr+ re6paisenri im far additional cn6gtmatiorss- tf es- os.re Ac runw mho Vo eornsa,c warts "=MI i asc.:- as.v-.az-r•rscx-f rs>•_i.r:.c•v 3.:a,: Ervvclt: car.:CrxprWaare C3r.-s-_uor D M4e - llwx to -.SOX Mloc 43. 3Ct t?2CT.[1 E,-:;, as rrrye: :oormwwn 0"W 194W t f w OF., rink reCW%M a CCI .screres, chi tecottM OR tle FPAE-acomwa.- rumor see rrnee cr.e r0PT2W 0&V* to dea t x' 0W.4es i0Q-- -$ -roi LVII Glra. '.r +a Greer: -3- yr e.KA -4- F anfar erc•rt. T- F. eoe•a Pee sMW&. T tar Tar ''Al"r i x MC- SP-REMI-21-003v04 r EQUIPMENT SHROUD DETAILS S•.. l,': NTS SHOWN MOUNTED ON AN g'o POLE CLAMP. STRAP. AND THRU BOLT OPTIONS s. 0 , t3. 0 , l jI ( 2) 2 TRADE SIZE KNOCKOUTS FOR CABLE ENTRY/ EXIT ( CROSS CUT RUBBER GROMMETS INCLUDED) T-`• — RJLLY VENTED WITH GR487 COMPLIANT PERF PATTERNS tr f . J i UNIVERSAL POLE—? REMOVABLE 24_ Ll MOUNTING BRACKET Pi4NEL ACCESS 3- 3 di 777, y t- 3048.ETAtitPE? RESISTANT LATCH f ." _...Y-... WITH PADLOCK HASP K 7' TRADE SIZE KNOCKOUTS 7 TRADE SIZE KNOCKOIJk, TAMPED. RESISTANT MTO SCREWS 4. 0.— r-• •-•• SSC-760249%6X1X 3: 5747 11{ i METROCELL RADIO CONCEALMENT 6.r. V.E;: A 1 CoMMSCC*APE I— -- - --- verizon1 175 CALKINS ROAD I ROCHESTER, NY14623ectonicPRArnuu SOLUTlottls. axatrr ON LL5111MCL Tectonic Enlmav ig Conu *-(t , Geologists • tmd Suvgors, D.P-C. Frnj•ct Cup-focf Info 36 86tish Amerl=n Blva. Fhone: (5'f3 783-1630 Suits 101 ( 800 829-6531 Latham. NY 12110 www.tectomicengineen-ng.comWO NUMBER DRAWN BY REVIEWED BY 12861.115 LP I MP NO. DATE ISSUE 0 05/ 06/26 FOR REGULATORY 1 06/ 09/26 ADDED PAINT NOTE I UNAUTHORIZED AL ERATION uR ADDI?!ONS TO A PLAN BEARING THE SEAL OF A LICENSED EfGINEER OR LAND SLR'v? YOR IS A VIOLATION OF SECTION 7209 SLED VISION 2 OF THE NEW YORK STATE EDUCAi1ON LA'r1'- COPIES OF THIS DOCUMENT yi1THCUT A FACSIMILE OF THE SIGNATURE AND AN ORIGIMA'_ -EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAUD SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 01 1 ORIGINAL SIZE IN INCHES 22x34 FORI'',: AT) 0 ORIGINAL SIZE IN INCHES 111 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 & NY industrial code rule 753 requires no less than two working days notice, but not more than ten days notice. Before You Dig, Drill Or Blast! CALL US TOLL FREE 1-800-962-7962 UNDERGROUND FACILITIES PROTECTIVE ORGANIZATION New York Dig Safely. · · ·