Loading...
HomeMy WebLinkAbout20260778 58 Washington St Site Plan PlansCOVER S-1 SURVEY- [ Thompson Flemming Land Surveyors ] L-1.0 SITE PREPARATION AND DEMOLITION PLAN L-2.0 LAYOUT & MATERIALS PLAN L-3.0 GRADING PLAN L-3.1 STORM EXTENSION PLAN L-4.0 UTILITIES PLAN L-5.0 LIGHTING & LANDSCAPING PLAN L-6.0 SITE DETAILS L-6.1 SITE DETAILS 58 WASHINGTON STREET SITE PLAN SHEET INDEX: CITY OF SARATOGA SPRINGS STANDARD NOTES 1.ALL WORK MUST CONFORM TO ALL FEDERAL, STATE AND CITY CODES, SPECIFICATIONS, ORDINANCES, RULES AND REGULATIONS. 2.THE ELEVATION BASE FOR THE CONTOURS AND BENCHMARKS ARE BASED ON THE NATIONAL GEODETIC VERTICAL DATUM, 1929. 3.THE APPLICANT MUST SUBMIT A LETTER OF CREDIT ESTIMATE FOR PROJECT SITE WORK TO THE CITY ENGINEER FOR REVIEW AND APPROVAL. LETTER OF CREDIT FUNDS MUST BE POSTED WITH THE CITY PRIOR TO PLANNING BOARD CHAIR SIGNATURE ON FINAL PLAN. 4.THE CONTRACTOR MUST SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE CITY ENGINEER PRIOR TO ANY CONSTRUCTION. CONSTRUCTION INSPECTIONS BY A DESIGNATED REPRESENTATIVE OF THE APPLICANT ARE REQUIRED. THE COST OF THE CONSTRUCTION INSPECTIONS IS THE RESPONSIBILITY OF THE APPLICANT/DEVELOPER. 5.ALL PROPOSED EASEMENTS OR RIGHT-OF-WAY DEDICATIONS MUST BE VERIFIED AND APPROVED BY THE CITY ENGINEER PRIOR TO CONSTRUCTION. 6.THE APPLICANT MUST VERIFY THAT THE PROPOSED PROJECT CAN ACCOMMODATE THE TURNING MOVEMENTS OF ANY FIRE TRUCK THAT THE FIRE DEPARTMENT DESIGNATES. 7.THE CONTRACTOR MUST OBTAIN A STREET OPENING PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS FOR ANY WORK WITHIN THE STREET OR RIGHT-OF-WAY OF ANY CITY STREET, ROAD OR ALLEY. 8.CONTACT THE BUILDING INSPECTOR FOR A BLASTING PERMIT, IF BLASTING IS REQUIRED 9.ALL POINTS OF CONSTRUCTION INGRESS OR EGRESS SHALL BE MAINTAINED TO PREVENT TRACKING OR FLOWING OF SEDIMENT OR DEBRIS ONTO A PUBLIC RIGHT-OF-WAY. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES ALSO APPLY. 10.NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED UNTIL ALL SITE WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS; ALL DISTURBED SOILS OR BARE GROUND HAVE BEEN FULLY STABILIZED; AND AN AS-BUILT DRAWING HAS BEEN PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY ENGINEER. PROJECT LOCATION MAP SCALE: N.T.S. PROJECT VICINITY MAP SCALE: N.T.S. SITE / CIVIL:APPLICANT: Adelphi Owners, LLC 200 Robbins Lane Jericho, NY September 2, 2026 BR O A D W A Y WASHINGTON STREET FE D E R A L S T R E E T EM B A S S Y S U I T E S SAR A T O G A S P R I N G S PROJECT SITE CO N G R E S S S T R E E T SPRING STREET PHILA STREET RA I L R O A D P L A C E DIVISI O N S T R E E T FR A N K L I N S T R E E T S O U T H F R A N K L I N S T R E E T WASHINGTON STREET FE D E R A L S T R E E T CO N G R E S S S T R E E T FR A N K L I N S T R E E T E B E E K M A N S T R E E T EM B A S S Y S U I T E S SAR A T O G A S P R I N G S PROJECT SITE Planning Board #XXXXXXXX So u t h F e d e r a l S t . Washington Street Railroad Pl. CONCRETE WASHOUT2 L-6.0 SILT FENCE3 L-6.0 STABILIZED CONSTRUCTION ENTRANCE 1 L-6.0 REMOVE CONCRETE CURB REMOVE CONCRETE CURB REMOVE FENCE, TYP. REMOVE FENCE, TYP. REMOVE FENCE, TYP. REMOVE ASPHALT PAVEMENT REMOVE GRAVEL INLET PROTECTION4 L-6.0 SAWCUT AND REMOVE ASPHALT PAVEMENT REMOVE AND STOCKPILE EXISTING SIGN REMOVE EXISTING COBRA STYLE LIGHT POLE CUT AND CAP EXISTING WATER SERVICE REMOVE CONCRETE SIDEWALK SAWCUT AND REMOVE ASPHALT PAVEMENT AND CURB TO FACILITATE SANITARY CONNECTION Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 SITE PREPARATION AND DEMOLITION PLAN L-1.0 MCB AKN DBH 8/27/2026 1"=10' 1.EXISTING CONDITIONS ARE TAKEN FROM A SURVEY PLAN ENTITLED "BOUNDARY & TOPOGRAPHIC SURVEY FOR BEECHWOOD HOMES SITUATE AT 58 WASHINGTON STREET", DATED 07/06/2025, AS PREPARED BY THOMPSON FLEMING LAND SURVEYORS, PC. HORIZONTAL AND VERTICAL DATUM IS AS NOTED ON THE PROJECT SURVEY. 2.PRIOR TO COMMENCING ANY EXCAVATION WORK, THE CONTRACTOR SHALL CONTACT U.F.P.O. (1-800-962-7962) AND THE PROPER LOCAL AUTHORITIES OR RESPECTIVE UTILITY COMPANY HAVING JURISDICTION TO CONFIRM THE LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. ANY COSTS INCURRED BY THE CONTRACTOR DUE TO FAILURE TO CONTACT THE PROPER AUTHORITIES SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 3.THE LOCATIONS OF ALL UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (WALLS, FENCE, FOOTINGS, TREE ROOTBALLS, PROPOSED LIGHTING FOOTINGS, ETC.). EXCAVATION REQUIRED WITHIN PROXIMITY OF UTILITY LINES SHALL BE DONE BY HAND. ANY DAMAGE AND INCURRED COSTS DUE TO FAILURE OF THE CONTRACTOR TO CONTACT THE PROPER AUTHORITIES SHALL BE BORNE BY THE CONTRACTOR. 4.THE GENERAL CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS IN THE FIELD AND REPORT ANY DISCREPANCY BETWEEN THE PLANS AND THE ACTUAL FIELD CONDITIONS TO THE LANDSCAPE ARCHITECT. 5.LIMIT OF WORK LINE IS NOTED ON DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGE DUE TO OPERATIONS INSIDE AND OUTSIDE OF THE CONTRACT LIMIT LINE. ANY AREAS OUTSIDE THE LIMIT OF WORK THAT ARE DISTURBED SHALL BE RESTORED TO ITS ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL MEET LINE AND GRADE OF EXISTING CONDITIONS AT LIMIT OF WORK LINE. IF NO LIMIT OF WORK IS SHOWN, THE PROPERTY LINE SHALL BE THE LIMIT OF WORK. 6.THE CONTRACTOR SHALL ESTABLISH PERMANENT BENCH MARKS. MAINTAIN ALL ESTABLISHED BOUNDS AND BENCH MARKS AND REPLACE AS DIRECTED ANY WHICH ARE DESTROYED OR DISTURBED. 7.CONTRACTOR SHALL EMPLOY SPECIAL CARE IN SCHEDULING CONSTRUCTION SO AS TO MAINTAIN EXISTING VEHICULAR TRAFFIC PATTERNS, AND MINIMIZE DISRUPTION TO SURROUNDING PEDESTRIAN TRAFFIC. CONTRACTOR SHALL EMPLOY SPECIAL CARE TO PROTECT SAFETY OF PEDESTRIANS INSIDE AND OUTSIDE OF THE LIMIT OF WORK LINE. 8.IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL REQUIRED PERMITS FROM ALL JURISDICTIONS AFFECTED BY THIS WORK ARE IN PLACE PRIOR TO CONSTRUCTION. FOR PERMITS ALREADY ISSUED, CONTRACTOR SHALL OBTAIN COPIES OF PERMITS AND STRICTLY ADHERE TO PERMIT CONDITIONS. PERMITS THAT ARE OUTSTANDING SHALL BE SECURED BY THE CONTRACTOR AND COORDINATED WITH THE OWNER'S REPRESENTATIVE. 9.ALL ALTERATIONS TO THESE DRAWINGS MADE IN THE FIELD DURING CONSTRUCTION SHALL BE RECORDED BY THE CONTRACTOR ON "AS-BUILT DRAWINGS," AS SPECIFIED. 10.STORAGE AREAS FOR THE GENERAL CONTRACTOR'S EQUIPMENT AND MATERIALS SHALL BE LOCATED WITHIN THE LIMITS OF WORK AS SHOWN ON THE PLANS OR AS APPROVED BY THE OWNER'S REPRESENTATIVE. 11.SHOULD ANYTHING BE OMITTED FROM THE PLANS WHICH IS NECESSARY FOR A COMPLETE UNDERSTANDING OF THE WORK, OR SHALL ANY ERROR APPEAR IN THE VARIOUS INSTRUMENTS FURNISHED OR IN THE WORK BY OTHER CONTRACTORS AFFECTING THE WORK COVERED HEREBY, THE CONTRACTOR SHALL AND WILL PROMPTLY NOTIFY THE OWNER'S REPRESENTATIVE, AND IN THE EVENT OF THE CONTRACTOR'S FAILURE TO DO SO, HE SHALL AND WILL MAKE GOOD OF ANY DAMAGE OR DEFECT IN HIS WORK CAUSED THEREBY. 12.PROVIDE EXPANSION JOINTS AT ALL CURBS, WALLS, STEPS, LIGHT POLE BASES, PULL BOXES, MANHOLES, TRAFFIC CONTROLLER BOXES AND AS SHOWN ON PLAN. 13.CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF ALL EXISTING INFRASTRUCTURE FOR THE DURATION OF CONSTRUCTION. CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT, ROADWAYS AND DRIVEWAYS. 14.THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS EFFORTS OF DEMOLITION, REMOVALS AND OR RELOCATION WORK WITH ALL TRADES, IF APPLICABLE. CONSULT ALL DRAWINGS AND SPECIFICATIONS FOR COORDINATION REQUIREMENTS BEFORE COMMENCING CONSTRUCTION. 15.CONTRACTOR TO COMPLY WITH ALL OSHA AND OTHER STATE AND LOCAL SAFETY REQUIREMENTS DURING CONSTRUCTION. 16.CONTRACTOR SHALL MAINTAIN PROPER SIGNS, BARRICADES, FENCES, TO PROPERLY PROTECT THE WORK, EQUIPMENT, PERSONS AND PROPERTY FROM DAMAGE. ALL DAILY TRAFFIC IN THE VICINITY OF THE SITE SHALL NOT BE IMPEDED. GENERAL NOTES 1.PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ARRANGE PRE-CONSTRUCTION MEETING WITH OWNER/OWNER'S REPRESENTATIVE TO REVIEW ALL APPLICABLE PERMIT CONDITIONS, THE CONSTRUCTION PLANS AND GENERAL CONSTRUCTION SCHEDULE. 2.THE CONTRACTOR'S ATTENTION IS DIRECTED TO THE GENERAL SURVEY NOTES, UTILITY NOTES AND UTILITY LOCATING SERVICE REQUIREMENTS. NO WORK SHALL COMMENCE UNTIL UNDERGROUND UTILITIES WITHIN THE SITE HAVE BEEN IDENTIFIED AND LOCATED. 3.ALL EROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO ANY EARTH DISTURBING ACTIVITIES. REFER TO PROJECT PLANS, NOTES AND DETAILS. 4.THE GENERAL CONTRACTOR SHALL COORDINATE ALL ADJUSTMENT OR ABANDONMENT OF UTILITIES WITH THE RESPECTIVE UTILITY COMPANY AND PAY ALL ASSOCIATED COSTS. 1.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE INSIDE AND OUTSIDE THE LIMIT OF WORK DUE TO THEIR CONTRACT OPERATIONS. 2.CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT, ROADWAYS AND DRIVEWAYS. 3.CONTRACTOR SHALL MAINTAIN NECESSARY TRAFFIC CONTROL DEVICES, DRUMS, DELINEATORS, SIGNS, FENCES, AND BARRICADES IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL MUTCD WITH NYS SUPPLEMENT TO PROPERLY PROTECT WORK, EQUIPMENT, PERSONS, AND PROPERTY FROM DAMAGE. 4.BEFORE ANY CLEARING IS DONE, THE CONTRACTOR SHALL ARRANGE A CONFERENCE ON THE SITE WITH THE LANDSCAPE ARCHITECT TO IDENTIFY TREES WHICH ARE TO BE PROTECTED OR REMOVED. DO NO CLEARING WITHOUT A CLEAR UNDERSTANDING OF EXISTING CONDITIONS TO BE PRESERVED. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL EXISTING TREES AND PLANTS DESIGNATED TO REMAIN FOR THE LENGTH OF THE CONSTRUCTION PERIOD AND SHALL, AT A MINIMUM, INSTALL TREE PROTECTION FENCE IN ACCORDANCE WITH PROJECT PLANS, DETAILS AND SPECIFICATIONS. VEHICLES SHALL NOT BE PARKED WITHIN THE DRIP LINE OR WHERE DAMAGE MAY RESULT TO TREES TO BE SAVED, AND CONSTRUCTION MATERIALS SHALL NOT BE STORED BENEATH TREES TO BE SAVED. 6.THE CONTRACTOR SHALL REVIEW THE LOCATIONS OF THE TREE PROTECTION FENCING FOR APPROVAL BY THE OWNER'S REPRESENTATIVE PRIOR TO INITIATION OF SITE WORK OPERATIONS. 7.AT ALL LOCATIONS WHERE EXISTING PAVEMENT ABUTS NEW CONSTRUCTION, THE EDGE OF THE EXISTING PAVEMENT SHALL BE SAW CUT TO A CLEAN, SMOOTH AND SHARP EDGE AND PROTECTED UNTIL ABUTTING MATERIALS ARE INSTALLED. 1.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S REPRESENTATIVE ON ALL MATERIALS TO BE REMOVED AND RECYCLED/DISPOSED OF OFF SITE. ALL HANDLING OF MATERIALS TO BE REMOVED, RECYCLED, OR DISPOSED OF MUST BE DONE SO IN A SAFE, LEGAL MANNER, IN ACCORDANCE WITH ALL LOCAL, COUNTY, STATE, FEDERAL AND ANY OTHER APPLICABLE REGULATIONS. 2.ALL ITEMS REQUIRING REMOVAL SHALL BE REMOVED TO FULL DEPTH TO INCLUDE BASE MATERIAL AND FOOTINGS OR FOUNDATIONS AS APPLICABLE UNLESS OTHERWISE NOTED. 3.EXISTING ITEMS INDICATED TO BE SALVAGED OR STOCKPILED SHALL BE CAREFULLY REMOVED AND STORED AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 4.TREE, SHRUB AND VEGETATION REMOVAL SHALL INCLUDE THE FILLING, CUTTING, GRUBBING OUT OF ENTIRE ROOT SYSTEM AND SATISFACTORY OFF-SITE DISPOSAL OF ALL TREES, SHRUBS, STUMPS, VEGETATIVE AND EXTRANEOUS DEBRIS PRODUCED THROUGH THE REMOVAL OPERATIONS. FELL TREES IN SUCH A WAY AS TO NOT DAMAGE ADJACENT BUILDINGS OR OTHER TREES TO BE SAVED. 5.CONTRACTOR SHALL STRIP AND STOCKPILE EXISTING TOPSOIL TO FULL DEPTH WITHIN LIMIT OF GRADING BEFORE COMMENCING EXCAVATION AND GRADING OPERATIONS. TOPSOIL SHALL NOT BE REMOVED FROM THE SITE, UNLESS APPROVED BY THE OWNER'S REPRESENTATIVE. SITE PREPARATION NOTES: PROTECTION NOTES: REMOVALS NOTES: LEGEND PROPERTY LINE EXISTING GAS LINE EXISTING OVERHEAD UTILITY EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND WATER REMOVE ITEM REMOVE CONCRETE PAVEMENT REMOVE ASPHALT PAVEMENT EXISTING UNDERGROUND TELECOMMUNICATIONS SILT FENCE 86425 10100 Scale: 1" = 10' Planning Board #XXXXXXXX REMOVE GRAVEL So u t h F e d e r a l S t . Washington Street Railroad Pl. UP UP DN UP R20' R5. 0 0 ' R 5 . 0 0 ' R5. 0 0 ' 3.98' 6. 0 0 ' 3. 3 8 ' 9. 8 3 ' 3. 5 3 ' 3.96'6.00'4.23' 6.05' 1.52' 1. 4 6 ' DROP CURB WITH DETECTABLE WARNING PLATE PROPOSED BUILDING COMMERCIAL DRIVEWAY DROP CURB 6 L-6.1 CONCRETE CURB CONCRETE SIDEWALK DROP CURB WITH DETECTABLE WARNING PLATE 1 2 3 4 5 6 7 8 9 10 UP UP 15 14 13 12 11 27 29 31 33 35 37 39 26 28 30 32 34 36 38 16 17 18 19 20 21 22 23 24 25 Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 LAYOUT & MATERIALS PLAN L-2.0 MCB AKN DBH 8/24/2026 1"=10' Planning Board #XXXXXXXX LEGEND PROPERTY LINE CONCRETE WALK ASPHALT PAVING 6 L-6.0 86425 10100 Scale: 1" = 10' Scale: 1"=20' BASEMENT FLOOR PARKING1 So u t h F e d e r a l S t . Washington Street Railroad Pl. 306.18 306.3 306.5 310.10 EX. 309.68 EX. 309.30 312.60 312.70 312.50 FFE: 310.15 316.00 310.00 310.00 310.15 EX311.04 312.45 314.90 314.80 315.00 CB-1 RIM: 304.50 INV IN: 300.10 INV OUT: 300.00 MATCH SHEET L-3.0 MATCH SHEET L-3.1 8" HDPE CONNECT TO ROOF DRAIN Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project 7itle: Prepared for: Drawing 7itle Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 GRADING ANDDRAINAGE PLAN L-3.0 MCB AKN DBH 8/28/2026 1"=10' 86425 10100 Scale: 1" = 10' Planning Board #XXXXXXXX 1.EXISTING BASE INFORMATION DERIVED FROM FIELD SURVEY DATED 07/06/26 PERFORMED BY THOMPSON FLEMING LAND SURVEYORS, PC. 2.ALL PROPOSED GRADES SHALL BE SET IN THE FIELD BY A NEW YORK STATE LICENSED LAND SURVEYOR. 3.CONTRACTOR SHALL ESTABLISH PERMANENT SECONDARY BENCHMARKS PRIOR TO THE START OF CONSTRUCTION. ALL SECONDARY BENCHMARKS SHALL BE SO LOCATED THAT THEY WILL NOT BE DISTURBED BY CONSTRUCTION. 4.PITCH EVENLY BETWEEN SPOT GRADES. ALL PAVED AREAS MUST PITCH TO DRAIN AT A MINIMUM SLOPE OF ONE-EIGHTH INCH (1/8") PER FOOT. MAXIMUM CROSSPITCH OF ALL SIDEWALKS IS 2%. ANY DISCREPANCIES NOT ALLOWING THIS TO OCCUR SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. 5.MAXIMUM CROSSPITCH OF ALL SIDEWALKS IS 2%. RAMPS SHALL NOT EXCEED 1 IN 12 OR 30' IN LENGTH. ANY DISCREPANCIES NOT ALLOWING THIS TO OCCUR SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. 6.SITE PAVEMENT SHALL MEET ALL BUILDING DOOR THRESHOLDS FLUSH AND IN ACCORDANCE WITH ADA GUIDELINES. 7.ALL PROPOSED TOP OF VERTICAL CURB ELEVATIONS ARE SIX INCHES (6") ABOVE BOTTOM OF CURB UNLESS SHOWN OTHERWISE. 8.WHERE NEW PAVING MEETS EXISTING PAVING, NEW PAVING SHALL MEET THE LINE AND GRADE OF THE EXISTING PAVING. 9.SET CATCH BASIN AND DROP INLET RIMS TO DRAIN SURROUNDING AREAS AND AT SAME PITCH AS SLOPING PAVEMENT. IF STRUCTURE IS SHOWN ADJACENT TO CURB, SET GRATE TIGHT TO FACE OF CURB. 10.EXCAVATION REQUIRED WITHIN 3 FEET OF EXISTING UTILITY LINE SHALL BE DONE BY HAND. CONTRACTOR SHALL REPAIR ANY DAMAGE TO EXISTING UTILITY LINES OR STRUCTURES INCURRED DURING CONSTRUCTION OPERATIONS AT NO ADDITIONAL COST TO OWNER. 11.CONTRACTOR SHALL STRIP AND STOCKPILE EXISTING TOPSOIL TO FULL DEPTH WITHIN LIMIT OF GRADING BEFORE COMMENCING EXCAVATION AND GRADING OPERATIONS. NO TOPSOIL SHALL BE REMOVED FROM SITE WITHOUT PRIOR AUTHORIZATION FROM OWNER. TOPSOIL SHALL BE STOCKPILED FOR RE-USE ON SITE OR LEGALLY DISPOSED OF OFFSITE. 12.ALL AREAS REQUIRING FILL SHALL BE BROUGHT TO REQUIRED GRADE IN 6" MAXIMUM COMPACTED LIFTS. GENERAL FILL SHALL BE FREE OF DELETERIOUS MATERIAL, CONTAIN NO GRAVEL LARGER THAN 2", AND SHALL BE COMPACTED IN ACCORDANCE WITH PROJECT PLANS AND DETAILS. 13.GRADE AREAS ADJACENT TO BUILDING LINES TO DRAIN AWAY FROM STRUCTURE AND PREVENT PONDING. FINISH SURFACES SHALL BE FREE FROM IRREGULAR SURFACE CHANGES. 14.EXCAVATION REQUIRED WITHIN DRIP LINE OF TREES DESIGNATED TO REMAIN SHALL BE DONE BY HAND. PLANT MATERIALS DAMAGED BY CONTRACTOR SHALL BE REPLACED IN KIND. 15.SLOPE SIDES OF EXCAVATIONS TO COMPLY WITH LOCAL CODES AND ORDINANCES HAVING JURISDICTION AND OSHA REGULATIONS. MAINTAIN SIDE SLOPES OF EXCAVATIONS IN A SAFE CONDITION UNTIL COMPLETION OF BACKFILLING. 16.THE GENERAL CONTRACTOR SHALL MAINTAIN OR ADJUST TO NEW FINISH GRADE AS NECESSARY ALL UTILITY AND SITE STRUCTURES SUCH AS LIGHT POLES, SIGN POLES, MAN HOLES, CATCH BASINS, HAND HOLES, WATER AND GAS GATES, HYDRANTS, ETC., FROM MAINTAINED UTILITY AND SITE SYSTEMS UNLESS OTHERWISE NOTED ON THE UTILITY DRAWINGS OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 17.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY INTO EXISTING, PROVIDING VERTICAL CURVES OR ROUNDINGS AT ALL TOP AND BOTTOM OF SLOPES. 18.CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING DRAINAGE SYSTEM AT ALL TIMES. DURING EARTHWORK OPERATIONS, DRAINAGE OF THE SITE AND ADJACENT AREAS SHALL BE MAINTAINED CONTINUOUSLY TO PREVENT EROSION OR DAMAGE RESULTING FROM CONCENTRATED RUN-OFF. WHEN IT IS NECESSARY TO INTERRUPT THE EXISTING DRAINAGE PATTERNS AND/OR UTILITIES, PROVIDE TEMPORARY FACILITIES UNTIL WORK IS PERMANENTLY STABILIZED AND APPROVED BY OWNER'S REPRESENTATIVE. 19.THE GENERAL CONTRACTOR SHALL MAINTAIN OR ADJUST TO NEW FINISH GRADE AS NECESSARY ALL UTILITY AND SITE STRUCTURES SUCH AS LIGHT POLES, SIGN POLES, MAN HOLES, CATCH BASINS, HAND HOLES, WATER AND GAS GATES, HYDRANTS, ETC., FROM MAINTAINED UTILITY AND SITE SYSTEMS UNLESS OTHERWISE NOTED ON THE UTILITY DRAWINGS OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 20.IN ALL LAWN AREAS, ROUGH GRADE SHALL BE BROUGHT TO WITHIN 4" OF FINISHED GRADE UNLESS OTHERWISE NOTED. 21.THE SIDES OF ANY NEW CUT AND/OR FILL SLOPES SHALL BE CONSTRUCTED W/ SLOPES NO STEEPER THAN 1 FOOT (VERTICAL) ON 2 FOOT (HORIZONTAL). GRADING NOTES: PROPERTY LINE MAJOR CONTOUR MINOR CONTOUR 850 EXISTING CONTOUR850 PROPOSED SPOT ELEVATION857 852 LEGEND Federal Street CB-2 RIM: 299.46 INV IN: 295.16 INV OUT: 295.06 CB-3 RIM: 296.10 INV IN: 289.52 INV OUT: 289.47 12" HDPE12" HDPE MA T C H S H E E T L - 3 . 0 MA T C H S H E E T L - 3 . 1 CORE STRUCTURE TO ACCEPT NEW STORM LINE INV IN: 289.23 REMOVE AND REPLACE CURB TO FACILITATE NEW STORM INFRASTRUCTURE SAWCUT, REMOVE AND REPLACE ASPHALT PAVEMENT TO FACILITATE NEW STORM INFRASTRUCTURE CONDUCT TEST PIT PRIOR TO STORM INSTALLTION TO CONFIRM EXISTING WATERLINE DEPTH AND REPORT FINDINGS TO OWNERS REP CONDUCT TEST PIT PRIOR TO STORM INSTALLTION TO CONFIRM EXISTING WATERLINE DEPTH AND REPORT FINDINGS TO OWNERS REP Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 STORM EXTENSIONPLAN L-3.1 MCB AKN DBH 8/28/2026 1"=10' 86425 10100 Scale: 1" = 10' Planning Board #XXXXXXXX PROPERTY LINE MAJOR CONTOUR MINOR CONTOUR 850 EXISTING CONTOUR850 PROPOSED SPOT ELEVATION857 852 LEGEND ASPHALT PAVING 6 L-6.0 So u t h F e d e r a l S t . Washington Street Railroad Pl. 6"X10" TAPPING SLEEVE AND VALVE 6" DIP WATER SERVICE CONNECT TO EXISTING 10" SANITARY MAIN WITH CHIMNEY STYLE CONNECTION 8" SDR-26 SEWER SERVICE @ 1% MIN. SLOPE BLDG INV: 308.00 CONDUCT TEST PIT PRIOR TO STORM INSTALLATION TO CONFIRM EXISTING WATERLINE DEPTH AND REPORT FINDINGS TO OWNERS REP EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 UTILITIES PLAN L-4.0 MCB AKN DBH 8/28/2026 1"=10' LEGEND 86425 10100 Scale: 1" = 10' Planning Board #XXXXXXXX LEGEND POTABLE WATER LINE SANITARY SEWER LINE STORM SEWER LINE UNDERGROUND ELECTRIC LINE TELECOMMUNICATION LINE 1.PVC SANITARY SEWERS, FITTINGS AND SERVICE LATERALS TO PROPERTY LINES SHALL CONFORM TO AND BE INSTALLED AND TESTED IN ACCORDANCE WITH THE CITY OF SARATOGA SPRINGS AND SARATOGA COUNTY SEWER DISTRICT #1 STANDARDS. 2.ALL SEWER PIPING AND FITTINGS SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR PVC PIPE, ASTM DESIGNATION D-3034-78 OR LATEST REVISION AND TO THE DIMENSIONS AND TOLERANCES OF CLASSIFICATION SDR-26 WITH SINGLE GASKET PUSH-ON JOINTS. 3.INFORMATION AND SHOP DRAWINGS FOR MATERIALS USED SHALL BE SUBMITTED TO AND APPROVED BY THE DESIGN ENGINEER PRIOR TO THE PLACEMENT OF ANY ORDERS OF SAID MATERIALS. 4.FIELD ADJUSTMENTS SHALL BE APPROVED BY THE LA GROUP AND THE CITY OF SARATOGA SPRINGS, PRIOR TO INSTALLATIONS. SANITARY SEWER NOTES WATER SYSTEM NOTES 1.WATER MAINS AND SERVICES SHALL BE INSTALLED AT A MINIMUM DEPTH OF COVER BELOW FINISHED GRADE OF 5'-0". 2.SUBMIT APPROVED SHOP DRAWINGS FOR ALL WATER MAINS AND APPURTENANCES TO THE CITY ENGINEER PRIOR TO CONSTRUCTION. 3.ALL CAST IRON AND DUCTILE IRON FITTINGS SHALL BE MECHANICAL JOINT, DOUBLE CEMENT LINED, PAINT SEAL COATED, 350 P.S.I. PRESSURE RATING. 4.CHLORINATION, PRESSURE AND LEAKAGE TESTS OF WATER MAINS SHALL BE IN CONFORMANCE WITH THE CITY OF SARATOGA SPRINGS AND A.W.W.A. STANDARDS AND SHALL BE PERFORMED UNDER THE SUPERVISION OF THE CITY ENGINEER. BACTERIA EXAMINATION AFTER DISINFECTION AT A N.Y.S.D.O.H APPROVED LABORATORY WILL TAKE PLACE PRIOR TO TURNING WATER MAIN OVER TO THE CITY TO VERIFY SANITARY QUALITY. WATER SERVICE LINES ARE EXCLUDED FROM THIS REQUIREMENT. 5.THERE SHALL BE A MINIMUM HORIZONTAL SEPARATION OF TEN FEET (EDGE TO EDGE) BETWEEN ANY WATER MAIN AND ANY SANITARY OR STORM SEWER. THERE SHALL ALSO BE A MINIMUM VERTICAL SEPARATION OF EIGHTEEN INCHES BETWEEN ANY WATER MAIN AND ANY SANITARY OR STORM SEWER. 6.THRUST BLOCKING SHALL COMPLY WITH DETAILS ON THESE DRAWINGS AND CITY STANDARDS. 7.NEW WATER SERVICES FROM MAIN TO CURB STOP WILL BE INSTALLED WITH MINIMUM COVER SHOWN ON STANDARD DETAILS UNLESS ADJUSTMENT IS REQUIRED BECAUSE OF DEPTH OF EXISTING WATER MAIN. SERVICE SHALL BE BROUGHT TO MINIMUM DEPTH IN STANDARD DETAILS AS CLOSE TO THE MAIN AS POSSIBLE. 8.DURING ALL EXCAVATION IN WHICH THE EXISTING WATER MAIN IS OR CAN EASILY BE EXPOSED, THE CONTRACTOR SHALL LOCATE THE WATER LINE, BOTH HORIZONTALLY AND VERTICALLY. THIS INFORMATION SHALL BE PROVIDED TO THE CITY OF SARATOGA SPRINGS AND INCORPORATED IN THE AS-BUILT DRAWINGS. 9.THE CONTRACTOR SHALL PROVIDE TWO (2) BRONZE WEDGES AT EACH BELL JOINT OF PUSH-ON PIPE. 10.THE CONTRACTOR SHALL PROVIDE ID TAPE ABOVE WATER LINES AS SHOWN ON THE TRENCHING DETAIL. 11.VALVE BOXES 11.a.CAST IRON TWO PIECE VALVE BOX AS MANUFACTURED BY CLOW (MODEL F2494), OR APPROVED EQUAL. 11.b.COVER SHALL BE STAY-PUT TYPE (CLOW MODEL F2490), OR APPROVED EQUAL, AND BE CLEARLY MARKED "WATER". 12.VALVES 12.a.ALL VALVES UNDER 12 INCHES IN DIAMETER SHALL BE MECHANICAL JOINT RESILIENT WEDGE (R/W). 12.b.R/W VALVES, 3-INCHES AND LARGER, SHALL BE IRON BODY, NON-RISING STEM CONFORMING TO A.W.W.A. C509. GLAND BOLTS SHALL BE ZINC COATED STEEL. 12.c.ALL VALVES SHALL HAVE A MAXIMUM WORKING PRESSURE RATING OF 200 P.S.I.G. 12.d.ALL VALVES SHALL HAVE MECHANICAL JOINT ENDS CONFORMING TO ANSI AS1.10/AS1.11. 12.e.VALVES SHALL OPEN RIGHT (CLOCKWISE) WITH A STANDARD 2-INCH SQUARE OPERATING NUT WITH ARROW CAST INTO IT INDICATING THE DIRECTION OF OPENING. 12.f.EACH VALVE SHALL BE FURNISHED COMPLETE WITH NECESSARY NUTS, BOLTS, STUDS, AND GASKETS. 12.g.MUELLER A-2360 MJ RESILIENT, OR APPROVED EQUAL. 13.ALL WATER MAIN VALVES SHALL OPEN RIGHT (CLOCKWISE). 14.THE LOCATION OF UNDERGROUND UTILITIES INDICATED ON THE PLANS ARE FOR INFORMATION ONLY, AND ALL UTILITIES MAY NOT BE SHOWN. THE CONTRACTOR SHALL CONTACT DIG SAFELY NY (1-800-962-7962) AND THE PROPER LOCAL AUTHORITIES OR RESPECTIVE UTILITY COMPANY HAVING JURISDICTION TO FIELD VERIFY THE LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. ANY COSTS INCURRED BY THE CONTRACTOR DUE TO FAILURE TO CONTACT THE PROPER AUTHORITIES SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 15.WATER VALVE BOXES, EXISTING STRUCTURE RIMS, NEW STRUCTURE RIMS, ETC., SHALL BE ADJUSTED TO CONFORM TO NEW FINISHED PAVEMENT GRADES UNLESS OTHERWISE NOTED AND/OR DIRECTED BY THE OWNER'S REPRESENTATIVE. 1.THE CONTRACTOR SHALL CONTACT U.F.P.O. (1-800-962-7962) AND THE PROPER LOCAL AUTHORITIES OR RESPECTIVE UTILITY COMPANY HAVING JURISDICTION TO CONFIRM THE LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. ANY COSTS INCURRED BY THE CONTRACTOR DUE TO FAILURE TO CONTACT THE PROPER AUTHORITIES SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 2.CONTRACTOR SHALL COORDINATE ALL REQUIRED UTILITY INSPECTIONS BY THE AUTHORITY HAVING JURISDICTION IN ACCORDANCE WITH THEIR RESPECTIVE REQUIREMENTS. 3.LOCATION OF UTILITY CONNECTIONS AT BUILDING TO BE VERIFIED BASED ON FINAL BUILDING FOOTPRINT CONFIGURATION. 4.ALL UTILITY INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL REGULATORY, LOCAL MUNICIPAL AND BUILDING CODE REQUIREMENTS. 5.THE LOCATION OF UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE DIAGRAMMATIC FOR INFORMATION ONLY, AND MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. ALL UTILITIES MAY NOT BE SHOWN. CONTRACTOR SHALL COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (WALLS, FENCE, FOOTINGS, TREE ROOTBALLS, PROPOSED LIGHTING FOOTINGS, ETC.) AND IMMEDIATELY REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE. ANY DAMAGE AND INCURRED COSTS DUE TO FAILURE OF THE CONTRACTOR TO VERIFY UTILITY LOCATIONS SHALL BE BORNE BY THE CONTRACTOR. 6.EXCAVATION REQUIRED WITHIN PROXIMITY OF UTILITY LINES SHALL BE DONE BY HAND. 7.EXTEND DESIGNATED LIMIT OF WORK AS NECESSARY TO ACCOMPLISH SITE UTILITY WORK AS REQUIRED BY THESE DRAWINGS AND SPECIFICATIONS. 8.CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT ROADWAYS AND DRIVEWAYS FOR THE DURATION OF CONSTRUCTION. UTILITY NOTES EXISTING POTABLE WATER LINE EXISTING SANITARY SEWER LINE EXISTING STORM SEWER LINE EXISTING UNDERGROUND ELECTRIC LINE EXISTING TELECOMMUNICATION LINE PROPERTY LINE So u t h F e d e r a l S t . Washington Street Railroad Pl. UP UP DN UP 1 CO 1 GB 1 CO LAWN LAWN LAWN 648 PA DECORATIVE PEDESTRIAN STREET LIGHT, TYP DECORATIVE PEDESTRIAN STREET LIGHT, TYP Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 LANDSCAPE AND LIGHTING PLAN L-5.0 MCB AKN DBH 8/24/2026 1"=10' 86425 10100 Scale: 1" = 10' Planning Board #XXXXXXXX LEGEND (PLANTING) NEW SHRUB PROPERTY LINE 1.ALL NEW PLANT MATERIAL SHALL CONFORM TO THE MINIMAL GUIDELINES ESTABLISHED BY THE AMERICAN STANDARD FOR NURSERY STOCK PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, INC. PROVIDE QUALITY, SIZE, GENUS, SPECIES, VARIETY OF TREES AND SHRUBS INDICATED, AND ROOT BALL SIZE COMPLYING WITH APPLICABLE REQUIREMENTS OF ANSI Z60.1 “AMERICAN STANDARD FOR NURSERY STOCK.” ALL PLANTS SHOULD BE NURSERY GROWN UNDER CLIMATIC CONDITIONS SIMILAR TO THOSE IN THE LOCALITY OF THE PROJECT. 2.PLANT SIZES: MEASURE TREES AND SHRUBS ACCORDING TO ANSI Z60.1 WITH BRANCHES AND TRUNKS OR CANES IN THEIR NORMAL POSITION. TAKE CALIPER MEASUREMENTS 6 INCHES ABOVE GROUND FOR TREES UP TO 4-INCH CALIPER SIZE, MEASURE MAIN BODY OF TREE OR SHRUB FOR HEIGHT AND SPREAD; DO NOT MEASURE BRANCHES OR ROOTS TIP-TO-TIP. 3.ALL CONTAINER GROWN PLANTS SHALL SIZED ACCORDING TO ANSI Z60.1 FOR TYPE AND SIZE OF PLANT REQUIRED. PLANTS SHALL BE PREMIUM QUALITY, APPEAR 'FULL', OR 'HEAVY' WITHIN THEIR CONTAINER, AND BE REPRESENTATIVE OF THE CONTAINER SIZE SPECIFIED. PLANTS DEEMED TO BE SUBSTANDARD IN SIZE BY THE LANDSCAPE ARCHITECT WILL BE REJECTED. 4.ALL NEW PLANTS TO BE BALLED AND BURLAPPED OR CONTAINER GROWN UNLESS OTHERWISE NOTED ON PLANT LIST. 5.TREES SHOULD BE FRESHLY DUG DURING THE SEASON OF PLANTING, MARCH 1ST TO MAY 1ST FOR SPRING PLANTING AND OCTOBER 15TH TO DECEMBER 15TH FOR FALL PLANTING. PLANTS KNOWN AS FALL DIG HAZARDS SHALL BE DUG IN THE SPRING ONLY. 6.THE CONTRACTOR SHALL SUPPLY ALL NEW PLANT MATERIAL IN QUANTITIES SUFFICIENT TO COMPLETE THE PLANTING SHOWN ON THE DRAWINGS. 7.IN GENERAL, PLANT SPECIES SUBSTITUTIONS WILL NOT BE ACCEPTED. IF SPECIFIED MATERIAL IS NOT OBTAINABLE, CONTRACTOR SHALL SUBMIT PROOF OF NON-AVAILABILITY TO LANDSCAPE ARCHITECT ALONG WITH PROPOSED SUBSTITUTION. ANY PROPOSED SUBSTITUTIONS OF PLANT SPECIES SHALL BE MADE WITH PLANTS OF EQUIVALENT OVERALL FORM, HEIGHT, SIZE, BRANCHING HABIT, FLOWER, LEAF, COLOR, FRUIT AND CULTURE, AND ONLY AFTER WRITTEN APPROVAL OF THE LANDSCAPE ARCHITECT. 8.THE LANDSCAPE ARCHITECT RETAINS THE RIGHT TO INSPECT TREES AND SHRUBS FOR SIZE AND CONDITION OF BALLS AND ROOT SYSTEMS, INSECTS, INJURIES AND LATENT DEFECTS, AND TO REJECT UNSATISFACTORY OR DEFECTIVE MATERIAL AT ANY TIME DURING PROGRESS OF WORK. CONTRACTOR SHALL REMOVE REJECTED TREES OR SHRUBS IMMEDIATELY FROM PROJECT SITE. 9.CONTRACTOR SHALL LOCATE AND VERIFY ALL EXISTING UTILITY LINES PRIOR TO PLANTING AND SHALL REPORT ANY CONFLICTS TO THE LANDSCAPE ARCHITECT. 10.THE CONTRACTOR SHALL STAKE THE LOCATIONS OF ALL PROPOSED PLANT MATERIAL AND PLANT BEDS FOR APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF PLANTING. 11.INSTALLED PLANTS SHALL BEAR THE SAME RELATIONSHIP TO PROPOSED GRADE AS THEY BORE TO PREVIOUS GRADE. NO TREES SHALL BE PLANTED BEFORE ACCEPTANCE OF ROUGH GRADING. 12.CONTRACTOR SHALL PROVIDE LONG LASTING, SLOW RELEASE STARTER FERTILIZER IN EACH PLANTING PIT FOR TREES, SHRUBS AND PERENNIALS. 13.ALL PLANT BEDS SHALL RECEIVE THREE INCHES (3") OF SHREDDED BARK MULCH. MULCH SHALL BE FREE FROM DELETERIOUS MATERIALS AND SUITABLE AS A TOP DRESSING OF TREES AND SHRUBS, CONSISTING OF DOUBLE HAMMERED SHREDDED BARK MULCH COMPRISED OF EITHER HARDWOOD OR SOFTWOOD SHREDDED BARK. SHREDDED BARK MULCH SHALL NOT EXCEED 3" IN GREATEST DIMENSION, AND SHALL BE DARK BROWN IN COLOR. 14.PLANTS SHALL BE DELIVERED ONLY AS THEY CAN BE INSTALLED IN REASONABLE TIME. ALL PLANTS ARE SUBJECTED TO INSPECTION AT DELIVERY BY THE LANDSCAPE ARCHITECT / OWNER'S REPRESENTATIVE. 15.IF DISCREPANCIES EXIST BETWEEN THE NUMBER OF PLANTS DRAWN ON THE PLANTING PLAN AND THE NUMBER OF PLANTS IN THE PLANT LIST, THE PLANTING PLAN SHALL GOVERN. 16.MAINTENANCE SHALL BEGIN IMMEDIATELY AFTER EACH PLANT IS PLANTED AND SHALL CONTINUE FOR A MINIMUM 30-DAY MONITORING PERIOD AFTER NOTIFICATION OF SUBSTANTIAL COMPLETION, AND UNTIL FINAL ACCEPTANCE, WHICHEVER IS GREATER. MAINTENANCE INCLUDES PRUNING, WEEDING, WATERING, FERTILIZATION, AND RE-SEEDING AS NECESSARY. 17.PROTECT PLANTS FROM DAMAGE DUE TO LANDSCAPE OPERATIONS AND OPERATIONS OF OTHER CONTRACTORS AND TRADES. MAINTAIN PROTECTION DURING INSTALLATION AND MAINTENANCE PERIODS. TREAT, REPAIR, OR REPLACE DAMAGED PLANTINGS. 18.UPON COMPLETION OF ALL PLANTING WORK, THE CONTRACTOR SHALL REQUEST IN WRITING THAT THE LANDSCAPE ARCHITECT FORMALLY INSPECT THE PLANTING WORK. IF PLANT MATERIALS AND WORKMANSHIP ARE ACCEPTABLE, THE LANDSCAPE ARCHITECT WILL ISSUE A WRITTEN CERTIFICATE OF SUBSTANTIAL COMPLETION. 19.FOLLOWING THE ISSUANCE OF THE CERTIFICATE OF SUBSTANTIAL COMPLETION TO THE CONTRACTOR, THE CONTRACTOR SHALL MAINTAIN THE PLANTS FOR THE MAINTENANCE PERIOD SPECIFIED IN THIS SECTION. 20.ACCEPTANCE STANDARDS AT END OF THE MAINTENANCE PERIOD: 20.1.PLANTS SHALL BE FREE OF FROST CRACKS; SUN SCALD; DAMAGE DUE TO INSECTS, PESTS, AND DISEASE; STRUCTURAL DEFECTS; AND DAMAGE RESULTING FROM MACHINERY OR TOOLS. ALL PLANTS REGARDLESS OF THE SEASON OF REVIEW SHALL HAVE A MINIMUM OF 75 PERCENT HEALTHY, BALANCED BRANCHING STRUCTURE WITH A HEALTHY TERMINAL LEADER(S) WITH VIABLE TERMINAL BUD(S). TREES SHALL BE PLUMB AND SHOW NO SIGNS OF UNEVEN SETTLING OR LEANING. 20.2.LAWN AREAS SHALL HAVE A HEALTHY, UNIFORM STAND OF GRASS FREE OF WEEDS, SURFACE IRREGULARITIES, WITH COVERAGE EXCEEDING 90% OVER ANY 10 SQ. FT. AND BARE SPOTS NOT EXCEEDING 5"X5" 21.IF PLANT MATERIALS AND WORKMANSHIP ARE ACCEPTABLE, THE LANDSCAPE ARCHITECT WILL ISSUE A WRITTEN CERTIFICATE OF FINAL ACCEPTANCE TO THE CONTRACTOR. 22.GUARANTEE: CONTRACTOR SHALL GUARANTEE ALL PLANT MATERIAL TO REMAIN ALIVE AND BE IN A HEALTHY, VIGOROUS CONDITION FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE OF PLANTING WORK, AGAINST DEFECTS INCLUDING DEATH AND UNSATISFACTORY WORK. 23.CONTRACTOR SHALL REPLACE ALL PLANTS THAT ARE MORE THAN 25% DEAD OR, AS DETERMINED BY THE LANDSCAPE ARCHITECT, ARE IN AN UNHEALTHY OR UNSIGHTLY CONDITION. CONTRACTOR SHALL BEAR THE COST OF COMPLETE REPLACEMENT(S). REPLACEMENTS SHALL BE OF THE SAME SIZE AND SPECIES AS SPECIFIED ON THE PLANTING LIST. 24.TOPSOIL SHALL HAVE A SANDY LOAM, LOAMY SAND, OR LOAM TEXTURE AS DETERMINED BY MECHANICAL ANALYSIS (ASTM 422) AND BASED ON THE 'USDA CLASSIFICATION SYSTEM' MAXIMUM CLAY CONTENT SHALL BE 10%. TOPSOIL SHALL BE FERTILE, FRIABLE SOIL FREE OF STONES LARGER THAN ONE INCH IN ANY DIRECTION, LUMPS, PLANTS AND THEIR ROOTS, DEBRIS AND OTHER EXTRANEOUS MATTER AS DETERMINED BY THE OWNER'S REPRESENTATIVE, AND TOXIC MATTER HARMFUL TO PLANT GROWTH, PLANTING NOTES: PROPOSED TREE PLANT LIST SYM.QTY.BOTANICAL NAME COMMON NAME SIZE REMARKS/SPACING DECIDUOUS TREES GB 1 Ginkgo Biloba 'Princeton Sentry'Princeton Sentry Ginkgo 2"-2.5"B&B male only CO 2 Celtis Occidentalis Hackberry 2.5"- 3"B&B GROUNDCOVERS PA 648 Pachysandra Terminalis Japanese Pachysandra Plugs, 12" O.C. TOPSOIL SPECIFICATION: GRADATION: SIEVE % PASSING BY WEIGHT CHEMICAL ANALYSIS MIN.MAX. #10 100 PH RANGE 5.2-7.0 #20 78 95 ORGANIC MATTER 4%-6% #40 67 87 MAGNESIUM 35LB. PER AC #60 48 78 PHOSPHORUS 75LB/AC #100 40 75 POTASSIUM 85LB/AC #200 28 63 SOLUBLE SALTS NOT TO EXCEED 500 PPM #270 22 55 .002 2 7 DECORATIVE PEDESTRIAN STREET LIGHT 50'-0" 12" THICK, 50/50 MIXTURE TYPE 3 AND TYPE 4 GRANULAR MATERIAL OVER GEOTEXTILE (MIRAFI 600X) R . 3 0 ' - 0 " T Y P . EDGE OF EXISTING ROADWAY CONSTRUCTION SPECIFICATIONS: 1.STONE SIZE- USE 1-4 INCH STONE, OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. 2.LENGTH- NOT LESS THAN 50 FEET (EXCEPT ON A SINGLE RESIDENCE LOT WHERE A 30 FOOT MIN. WOULD APPLY. 3.THICKNESS- NOT LESS THAN SIX (6) INCHES. 4.WIDTH- TWELVE (12) FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS OCCURS. GEOTEXTILE- WILL BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE. 5.ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ACCESS SHALL BE PIPED BENEATH THE ENTRANCE, IF PIPING IS IMPRACTICAL A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 6.THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OR SEDIMENT INTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 7.WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH STONE AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 8.PERIODIC INSPECTION AND DEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN EVENT. 24 ' - 0 " MI N . STRAWBALES STAKED INTO GROUND NOTE: 1.WASHOUT AREA SHALL BE SIZED BY THE CONTRACTOR TO ADEQUATELY CONTAIN CONCRETE CLEANOUT. 10 MIL PLASTIC LINING WOOD OR METAL STAKES (2 PER BALE) STAPLES (2 PER BALE) STRAW BALE 10 MIL PLASTIC LINING 8' MIN. 2' M I N . CONCRETE WASHOUT SIGN CONCRETE WASHOUT EXISTING PAVING TO REMAINPROPOSED PAVING TOP COURSE BINDER COURSE 1-/2" MINIMUM DEEP KEY INTO EXISTING PAVEMENT COMPACTED BASE MATERIAL KEYED PAVEMENT TO BE FLUSH WITH EXISTING PAVEMENT 1' NOTES: EXPANSION JOINT SPACING - 20'-25' O.C. CONTROL JOINT SPACING - 5' O.C. NOMINAL CROSS SLOPE - 1/8" TO 1/4" PER FOOT (MAX. SLOPE 1:50 TYP.) TOWARDS STREET OR A.O.B.E. MAX. SLOPE ALONG THE LENGTH OF THE WALK SHOULD NOT EXCEED 1:12 CONSTRUCTION JOINT DETAILS TO BE SUBMITTED AND APPROVED BY CITY ENGINEER SIDEWALK WIDTH TO BE 5' MIN. OR AS ORDERED BY CITY ENGINEER THESE GENERAL CONCRETE SPECIFICATIONS SHALL APPLY TO ALL CONCRETE WORK WITHIN THE CITY OF SARATOGA SPRINGS INSTALLED WITHIN A CITY RIGHT-OF-WAY AND/OR WITHIN THE APPROVAL AUTHORITY MINIMUM SPECIFICATIONS. ALL CONCRETE THAT MAY COME IN CONTACT WITH DEICING CHEMICALS SHALL MEET OR EXCEED THESE CONCRETE SHALL BE ONLY PORTLAND CEMENT CONCRETE AIR-ENTRAINED OF DURABLE MATERIALS AND SHALL HAVE (1) A LOW WATER-CEMENT RATIO (MAXIMUM 0.46), (2) A SLUMP OF 4 INCHES OR LESS,* (3) A CEMENT CONTENT OF 606 LB PER CUBIC YARD OR MORE, (4) PROPER FINISHING AFTER BLEED WATER HAS EVAPORATED FROM THE SURFACE, (5) ADEQUATE DRAINAGE WITH A SLOPE OF 1/8 INCH PER LINEAR FOOT OR MORE, (6) A MINIMUM OF 7 DAYS MOIST CURING AT OR ABOVE 50 DEGREES F, (7) A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS, AND (8) A MINIMUM 30-DAY DRYING PERIOD AFTER MOIST CURING IF CONCRETE IS PLACED IN THE FALL AND WILL BE EXPOSED TO FREEZE-THAW CYCLES AND DEICERS WHEN SATURATED. THE EXACT LENGTH OF TIME FOR SUFFICIENT DRYING TO TAKE PLACE MAY VARY WITH CLIMATE AND WEATHER CONDITIONS. TECHNICAL SPECIFICATIONS FOR CONCRETE AS HEREIN DEFINED SHALL COMPLY WITH THE APPLICABLE SPECIFICATIONS OF THE "NEW YORK STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS CONSTRUCTION AND MATERIALS", 1985. ANY CLARIFICATION, REVISIONS, MODIFICATIONS THERETO SHALL ONLY BE MADE SUBJECT TO APPROVAL OF THE CITY OF SARATOGA SPRINGS PLANNING BOARD. *A SUPER PLASTICIZER MAY BE USED TO INCREASE SLUMP AND WORKABILITY WITHOUT INCREASING THE WATER-CEMENT RATIO. CITY OF SARATOGA SPRINGS CONCRETE SPECIFICATIONS OF THE PLANNING BOARD BROOM FINISH PERPENDICULAR TO WALK 4" CONCRETE 6" X 6" NO 6 6 WOVEN WIRE MESH EXCEPT A.O.B.E. 6" GRANULAR SUBBASE COURSE NYS DOT SECT. 304, TYPE 2 COMPACTED TO 95% STANDARD PROCTOR SUBGRADE COMPACTED TO 90% STANDARD PROCTOR BROOM FINISH PERPENDICULAR TO WALK 6" CONCRETE - SEE CONCRETE SPECIFICATIONS 6" X 6" NO 6 6 WOVEN WIRE MESH EXCEPT A.O.B.E. 8" GRANULAR SUBBASE COURSE NYS DOT SECT. 304, TYPE 2 COMPACTED TO 95% STANDARD PROCTOR SUBGRADE COMPACTED TO 90% STANDARD PROCTOR TYPE 1 SIDEWALK TYPE 2 PARKING AREA NOTES: 1.PAVEMENT SECTIONS SPECIFIED ARE TYPICAL FOR STREET, DRIVEWAY AND PARKING LOT CONSTRUCTION WHERE TRAFFIC VOLUMES AND LOADINGS ARE NOT EXCESSIVE. BASED ON ANTICIPATED VOLUMES AND LOADS, THE CITY ENGINEER MAY REQUIRE STRUCTURAL PAVEMENT SECTION TO BE INCREASED TO CARRY DESIGN LOADING. 2.TACK COAT BINDER BEFORE PLACING TOP COARSE IF MORE THAN 48 HOURS HAVE ELAPSED AFTER PLACING BINDER COURSE. 3.FOR WORK WITHIN CITY ROW THE CITY ENGINEER MAY REQUIRE COMPACTION TESTING AND/OR CORE SAMPLES TO VERIFY PAVEMENT THICKNESS. ALL TESTING SHALL BE AS ORDERED BY THE CITY ENGINEER AND SHALL BE PAID BY THE CONTRACTOR. 4.NOTIFY THE CITY ENGINEER 48 HOURS MINIMUM PRIOR TO COMMENCING PAVING OPERATIONS. SUBGRADE OR STRUCTURAL FILL COMPACTED TO 95% MODIFIED PROCTOR COMPACTED GRAVEL - NYSDOT TYPE 2 (SECT. 304) COMPACTED TO 95% STANDARD PROCTOR DE P T H T O SU B G R A D E A S RE Q U I R E D BINDER COURSE - NYSDOT ITEM 402.198902 - 19F9 H.M.A., 80 SERIES COMPACTION PG BINDER (LIQUID ASPHALT) GRADE SHALL BE PG-64-22 TACK COAT - NYSDOT ITEM 407-0102 DILUTED TOP COURSE - NYSDOT ITEM 402.098302 - 9.5F3 H.M.A., 80 SERIES COMPACTION PAVEMENT TYPE TOP COURSE BINDER COURSE GRAVEL COURSE STREET 1-1/2"3"12" GEOTEXTILE FABRIC, MIIRAFI 500X 2'-23 8" 1' - 5 1 2" 2' - 8 " 6' 6'-1" 4" CONCRETE PAD4" CONCRETE PAD 6" GRANULAR SUBBASE 16 " 6" FLUSH CURB IN PAVING 1/ 2 " 6" 6" 6"6"6" PROVIDE CLEAN SQUARE CORNER WHERE BITUMINOUS WALK ABUTS CURB FINISH GRADE; BITUMINOUS OR LAWN, SEE PLANS 1/2" RADIUS FINISH GRADE 4,000 PSI CAST-IN-PLACE CONCRETE CURB COMPACTED GRAVEL BASE NYSDOT SECT. 304, TYPE 2 16 " A B O V E GR A D E 6" BE L O W G R A D E 10' MAX. ℄ TO ℄ 36" MIN., 2" HARDWOOD FENCE POSTS, DRIVEN MIN. 16" INTO GROUND 2' O V E R A L L FA B R I C H T . 20 " M I N . 16 " M I N . 36" MIN. FENCE POST FILTER FABRIC FLOW 6" MI N . EMBED FILTER CLOTH MIN. 6" INTO GROUND SECTION PERSPECTIVE VIEW FILTER FABRIC; FASTENED SECURELY TO FENCE POSTS W/ STAPLES FLOW FLOW CONSTRUCTION SPECIFICATIONS: 1.WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES. POSTS SHALL BE STEEL EITHER "T" OR "U" TYPE OR HARDWOOD. 2.FILTER CLOTH TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION. FENCE SHALL BE WOVEN WIRE 6' MAXIMUM MESH OPENING. 3.WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY SIX INCHES AND FOLDED. FILTER CLOTHE SHALL BE EITHER FILTER X, MIRAFI 100X, STABILINKA T140N, OR APPROVED EQUIVALENT. 4.PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE OR APPROVED EQUIVALENT. 5.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN "BULGES" DEVELOP IN THE SILT FENCE. 6.FILTER FABRIC SHALL BE ON THE NYSDOT APPROVED MATERIAL LIST FOR SILT FENCE, UNSUPPORTED 1.2M POST SPACING. EXPANSION JOINT CONTROL JOINT EXPANSION JOINTS TO OCCUR 30' O.C. MAX, WHERE CONCRETE MEETS VERTICAL SURFACES OR IMMOVABLE OBJECTS SUCH AS CURBS, WALLS, FOOTINGS ETC, AND IN LOCATIONS SHOWN ON PLANS. 1/4" 3/8" JOINT JOINT SEALANT TO 1/2" DEPTH TOOLED JOINT WITH 1/4" RADIUS EDGE BACKER ROD PREMOULDED JOINT FILLER. CUT BACK AS NECESSARY AFTER PLACEMENT 1/4 THE DEPTH OF THE CONCRETE SLAB TOOLED CONTROL JOINT. PLACE 5'-0" O.C. UNLESS OTHERWISE SHOWN ON PLANS. 3" 3" +/ - 3 4 " +/- 19-3/8" 4' 10 " 6"6"6"6" POWDER COATED BLACK STEEL BIKE RACK, MODEL 4180-IG-P BY BELSON OUTDOORS OR APPROVED EQUAL EXPANSION JOINT CONCRETE WALK 3 8" ANCHOR ROD CONCRETE FOOTING COMPACTED SUBGRADE NOTES: 1.VERIFY DIMENSIONS OF BICYCLE RACK & STAKE LOCATION PRIOR TO START OF FOOTING CONSTRUCTION & INSTALLATION 2.INSTALL EMBEDDED ANCHORING PER MANUFACTURERS SPECIFICATIONS FULL CURB AT LAWN 6" 6" 18 " 6" PAVEMENT 1 4" RADIUSFINISH GRADE CAST-IN-PLACE CONCRETE CURB, SEE CONCRETE SPECIFICATION GRAVEL COMPACTED TO 95% STANDARD PROCTOR SUBGRADE COMPACTED TO 90% STANDARD PROCTOR 7" NOTES: 1.FILTER BAG SHALL BE ADS FLEXSTORM CATCH-IT INLET FILTER, OR APPROVED EQUIVALENT. 2.PERFORMANCE STANDARD: AT A MINIMUM, THE FABRIC SHALL HAVE A MINIMUM GRAB TENSILE STRENGTH OF 120 LBS., A MINIMUM BURST STRENGTH OF 200 PSI, AND A MINIMUM TRAPEZOIDAL TEAR STRENGTH OF 50 LBS. FILTER BAGS SHALL BE CAPABLE OF TRAPPING ALL PARTICLES NOT PASSING A NO. 40 SIEVE. 3.INLET FILTER BAGS SHALL BE INSPECTED ON A WEEKLY BASIS AND AFTER EACH RUNOFF EVENT. 4.BAGS SHALL BE EMPTIED AND RINSED OR REPLACED WHEN HALF FULL OR WHEN FLOW CAPACITY HAS BEEN REDUCED SO AS TO CAUSE FLOODING OR BYPASSING THE INLET. 5.DAMAGED OR CLOGGED BAGS SHALL BE REPLACED IMMEDIATELY AFTER INSPECTION. 6.A SUPPLY SHALL BE MAINTAINED ON SITE FOR REPLACEMENT OF BAGS. ISOMETRIC VIEW CATCH BASIN INLET GRATE STEEL FRAME FOR BAG REMOVAL FROM CATCH BASIN FILTER BAG Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 SITE DETAILS L-6.0 DBH AKN DBH 8/24/2026 NTS Scale: NTS STABILIZED CONSTRUCTION ENTRANCE1 Scale: NTS CONCRETE WASHOUT2 Scale: NTS INLET PROTECTION4 Scale: NTS CONCRETE PAVEMENT5 Scale: NTS ASPHALT PAVEMENT6 Scale: NTS BENCH8 Scale: NTS FLUSH CONCRETE CURB9 Scale: NTS SILT FENCE 3 Planning Board #XXXXXXXX Scale: NTS CONCRETE JOINTS7 Scale: NTS PAVEMENT KEY10 Scale: NTS TRANSITION CURB11 Scale: NTS BIKE RACK12 6' (ADJACENT SIDEWALK) 3' (ADJACENT LAWN) ADJACENT SIDEWALK, 1:12 MAX 1' CONCRETE CURB 6" 3/8" EXPANSION JOINT ADJACENT FINISH GRADE AT BOTTOM OF CURB Scale: NTS 6" CONCRETE CURB13 NOTES: -TREE SHALL BEAR SAME RELATIONSHIP TO FINISH GRADE AS IN THE NURSERY. -THIN BRANCHES & FOLIAGE AS DIRECTED WHILE RETAINING NORMAL SHAPE OF TREE. NEVER CUT A LEADER. -TREE SHALL BE PLUMB & STRAIGHT. 12 " EQ.EQ. STAKE AND GUY TREE-CONTRACTOR SHALL PROVIDE METHOD AND MANUFACTURER SAMPLE TO OWNER'S REPRESENTATIVE FOR APPROVAL. NEATLY WRAP ALL DECIDUOUS TRUNKS TO A HEIGHT OF THE SECOND LOWEST BRANCH (FALL PLANTING ONLY) 3" DEPTH PINE BARK MULCH (OR STONE); PULL MATERIAL AWAY FROM TRUNK. 3" HT. PLANTING MIX SAUCER AMENDED PLANTING MIX, COMPACTED CUT ROPE SURROUNDING BOTTOM OF TREE TRUNK AFTER BACKFILLING BUT BEFORE MULCHING. DO NOT REMOVE BURLAP. NATIVE SOIL DRAINAGE MOUND, COMPACTED TO 92% UNDISTURBED SUBGRADE FULL LENGTH OF PIPE CENTERED ON SEWER LINE 18 " M I N . 5' - 0 " M I N . * SEE NOTE WATER LINE SANITARY SEWER OR STORM SEWER FINISHED GRADE NOTE: (REFERENCE - "TEN STATE STANDARDS") WHEN INSTALLED PARALLEL, ALL WATER AND SEWER LINES SHALL HAVE A MINIMUM SEPARATION OF 10', EDGE TO EDGE. IF MINIMUM CANNOT BE MAINTAINED, WATER MAIN SHALL BE IN SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF TO ONE SIDE OF SEWER WITH BOTTOM OF WATER MAIN 18" MINIMUM ABOVE TOP OF SEWER PIPE. WHEN CROSSING, MAINS SHALL BE INSTALLED TO INSURE 18" MINIMUM VERTICAL SEPARATION BETWEEN PIPES, OUTSIDE TO OUTSIDE. WHERE WATER MAIN IS UNDERNEATH SEWER, ADEQUATE STRUCTURAL SUPPORT SHALL BE PROVIDED FOR THE SEWER TO PREVENT DAMAGE TO WATER MAIN. WHEN IT IS IMPOSSIBLE TO PROVIDE THE ABOVE MINIMUMS, THE SEWER SHALL BE DESIGNED AND CONSTRUCTED EQUAL TO WATER PIPE, AND SHALL BE PRESSURE TESTED TO ASSURE WATERTIGHT PRIOR TO BACKFILLING. Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Adelphi Owner, LLC 200 Robbins Ln, Jericho, NY 11753 58 Washington St. 58 Washington Street Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020049.03 SITE DETAILS L-6.1 DBH AKN DBH 8/24/2026 NTS Scale: NTS DECIDUOUS TREE1 Planning Board #XXXXXXXX Scale: NTS CITY OF SARATOGA SPRINGS DECORATIVE STREET LIGHT3 Scale: NTS CITY OF SARATOGA SPRINGS- DROP CURB AT COMMERCIAL DRIVEWAY2 5' M I N . C O V E R 1 PIPE LENGTH (18'-0" MIN.) PROPOSED TAPPING SLEEVE EXISTING WATER MAIN 3,000 PSI MIN. CAST-IN-PLACE CONCRETE THRUST BLOCK UNEXCAVATED/ UNDISTURBED EARTH MECHANICAL JOINT TAPPING VALVE & M.J. RETAINER GLANDS 12" X 12" SOLID PRECAST CONCRETE BLOCKS (6" MIN. THICK) CRUSHED STONE PIPE BEDDING, AS SPECIFIED 6"Ø DIP MECHANICAL JOINT RETAINER GLAND FOR DIP PIPE, AS REQ'D. (2) 3/4" Ø THREADED TIE RODS, WASHERS & NUTS AS SPECIFIED; APPLY (2) COATS OF COAL TAR EPOXY PAINT FOLLOWING ASSEMBLY (20 MILS MIN. DFT TOTAL), TYP. PROPOSED FINISHED GRADE OR EXISTING GROUND LINE TELESCOPIC PATTERN VALVE BOX PER CITY OF SARATOGA SPRINGS STANDARD Scale: NTS WATER MAIN CONNECTION4 1' - 0 " MIN. MI N . PIPE O.D. 6" MIN. O.D./2 COMPACTION COMPACTION MECHANICAL COMPACTION MECHANICAL MECHANICAL PLACEMENT METHOD OF FINAL TRENCH BACKFILL PIPE ZONE BACKFILL 1 & 2 1 & 2 203.07 CRUSHED COVER VARIES 12' MIN. PIPE O.D./2 6" MIN. +PIPE ZONE BEDDING NYSDOT SIZEMATERIALDEPTHITEM NEW PVMT., SEE DETAIL PVMT. RESTORATIONLAWN RESTORATION 1 1 1 1 VA R I E S - A S R E Q ' D . 5' - 0 " M A X . V E R T . W A L L PIPE O.D. + 24" 8" 1' - 6 " AGGREGATE SAW-CUT EXIST. PVMT. IN TRUE LINE. KEY PVMT. AS SHOWN. TACK COAT EXPOSED EDGES OF EXIST. PVMT. PRIOR TO PLACEMENT OF NEW PAVEMENT. BURIED IDENTIFICATION WARNING TAPE EXIST. PVMT. SUBBASE MAT'L.; REFER TO NEW PVMT. DETAIL FINAL TRENCH BACKFILL (SEE NOTE) TOPSOIL & SEED AS SPECIFIED PIPE ZONE BACKFILL PIPE ZONE BEDDING MAT'L MIN. KEY JT. CRUSHED AGGREGATE NOTES: 1.ALL PIPE ZONE BEDDING, PIPE ZONE BACKFILL, AND FINAL TRENCH BACKFILL SHALL BE PLACED IN 6 INCH MAX. COMPACTED LIFTS. ALL BEDDING AND BACKFILL MATERIALS SHALL BE MECHANICALLY COMPACTED TO THE SATISFACTION OF THE ENGINEER. 2.EXCAVATION SHALL BE KEPT DRY AND DEWATERED AT ALL TIMES. SELECT GRANULAR FILL Scale: NTS TYPICAL PIPE TRENCH DETAIL5 D= D E P T H W=WIDTH A A 0.5 x 1.5 90° (1/4) BEND 45° (1/8) BEND NOTES: 81 V± = LD (W + I.D.) - I.D. 5. APPROXIMATE VOLUME OF CONCRETE THRUST BLOCK:1. FOR REQUIRED BEARING AREA AND DIMENSIONS L AND D, SEE SCHEDULE BELOW. VALUES OF L AND D OTHER THAN THOSE SHOWN IN THE TABLE MAY BE USED PROVIDED THEY YIELD A BEARING AREA EQUAL TO OR LARGER THAN THAT REQUIRED. 2. CONCRETE NOT TO OVERLAP ANY JOINT. 3. CONCRETE TO BE PLACED SO AS NOT TO INTERFERE WITH REMOVING OR INSTALLING ANY OF THE JOINTING HARDWARE. 4. BEARING AREAS FOR THRUST BLOCKS FOR WATER MAINS LARGER THAN 12" DIA. TO BE APPROVED BY CITY ENGINEER. WHERE: V = VOLUME IN CUBIC YARDS L = LENGTH OF BLOCK IN FEET D = DEPTH OF BLOCK IN FEET W = WIDTH OF BLOCK IN FEET I.D. = INSIDE DIAMETER OF PIPE IN FEET 6. REQUIRED BEARING AREAS ARE BASED ON ALLOWABLE SOIL BEARING CAPACITY OF 2000 p.s.i. (MEDIUM CLAY) WITH A SAFETY FACTOR OF 1.7. PRESSURE OF FLUID FLOW IS BASED ON A 300' HEAD. 7. IN MUCK, PEAT OR RECENTLY PLACED FILL ALL THRUST SHALL BE RESISTED BY PILES OR TIE RODS TO SOLID FOUNDATIONS, OR BY REMOVAL OF SUCH UNSTABLE MATERIAL AND REPLACEMENT WITH BALLAST OF SUFFICIENT STABILITY TO RESIST THRUSTS, ALL AS REQUIRED BY THE ENGINEER. PIPE SIZE INCHES AREA SQ. FT. AREA SQ. FT. AREA SQ. FT. 22-1/2° (1/16) BEND 11-1/4° (1/32) BEND DIMENSIONS D x L TEE DIMENSIONS DIMENSIONS 2.0 x 2.5 D x L 3.2 1.5 x 2.56 4.5 D x L 1.5 x 2.02.4 AREA SQ. FT. 1.2 D x L 1.0 x 1.5 0.6 AREA SQ. FT. DIMENSIONS D x L DIMENSIONS REQUIRED BEARING AREAS & DIMENSIONS FOR CONCRETE THRUST BLOCKS SECTION A-A PLAN (TYP.) WATER MAIN (OR SEWER FORCE MAIN) CONCRETE THRUST BLOCK SCHEDULE 4,000 P.S.I UNDISTURBED SOIL GRADE #30 ROOFING FELT THRUST BLOCK 1.0 x 2.03.0 x 4.58.8 2.5 x 3.510 12.5 2.0 x 3.06.8 3.4 1.5 x 2.5 1.7 1.5 x 2.04.0 x 4.512.7 3.5 x 3.512 18.0 2.5 x 4.09.7 5.0 2.0 x 2.5 2.5 Scale: NTS THRUST BLOCK7 24"MIN.EXISTING AND/OR FINISHED GRADE LATERAL CONNECTION SECTION PRESSURE TREATED 4"X4" LOCATION MARKER LABELED "SEWER END CAP" (TYP.) VARIES - 45° BEND MAX. VARIES - 45° BEND MAX. VARIES - 45° BEND MAX. AS REQUIRED 2% MINIMUM SLOPE (TYP) CAP (TYP.) BEDDING MATERIAL (TYP.) (SEE TRENCH DETAIL) MAIN SEWER MAIN SEWER VARIES - 45° BEND MAX. TEE, ONLY IF SPECIFIED OR ALLOWED BY THE ENGINEER PROPERTY LINE R.O.W. OR EASEMENT LIMIT WYE, 45° VARIES - 45° BEND MAX. AS REQUIRED 4" OR 6" INDIVIDUAL RESIDENTIAL BUILDING SEWER LATERAL (TYP.) 6" MIN. COMMERCIAL SEWER LATERAL (TYP.) NOTES: ·BUILDING SEWER LATERAL MATERIALS SHALL BE THE SAME AS THE MAIN SEWER LINE MATERIAL UNLESS OTHERWISE SPECIFIED. ·ALL GRAVITY SANITARY SEWER LINES SHALL BE AT A DEPTH OF 4' OR GREATER, IF LESS THAN 4', LINE SHALL BE INSULATED (SEE TRENCH DETAIL) ·CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING FLOW Scale: NTS SEWER SERVICE DETAIL8 Scale: NTS UTILITY CROSSING6 COMPACTED STRUCTURAL FILL