HomeMy WebLinkAbout20250566 33-35 Caroline St Site Plan Floor Plan and Building ElevationsDN
UP
DN UP
DN
1
A15
ELEVATOR 200 SF
PARKING OFFICE
RAMP UP 1/12
RAMP UP 1/12
677 SF
COMMON
210 SF
CAR ELEVATOR-1
181 SF
RESIDENT TRASH
ROOM
RAMP
UP 1/12
RESIDENTIAL
ENTRANCE
79 SF
MAIL ROOM
LOBBY
7'
-
1
0
"
12' - 2"
4'
-
0
"
25' - 9"4' - 9"
58
'
-
4
"
10' - 11"
B
B
E
C
D
D
C F G G
100
002
002
001
002
009
009
102
102 102
101
100
101 101BB
A
A
B B B B101
A1
1
5
A1 A1
A1
5
3
3
2
5
A1
A1
3
5
3
A1 A1
A1
A1 A1
A1 A1
A1
A1
A1A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
11
'
-
3
"
10
'
-
6
"
8'
-
8
"
23' - 8"8' - 1"20' - 2"11' - 6"15' - 5"11' - 6"17' - 3"
53' - 4"53' - 4"
22
'
-
1
0
"
5'
-
4
"
10
'
-
8
"
26
'
-
0
"
7'
-
4
"
20
'
-
8
"
88
'
-
9
"
4'
-
0
"
107' - 7"
92
'
-
9
"
3
11' - 3"7' - 2"
10
'
-
0
"
8' - 0"
3'
-
6
"
3'
-
6
"
3'
-
6
"
3' - 6"
5'
-
8
"
8'
-
1
1
"
8'
-
3
"
18
'
-
1
0
"
CMCM
CM
CM
CM
CM
CM
CM
CM
CM
1
A12
A1
A1
1
A13
RETAIL WASTE
BIN ZONE
107' - 7"
5
5
1
A B C D E F G H I J K L
2
3
4
5
6
7
8
9
10
J.2
6.5
K.7
9.8
14' - 3"
6
T2
NOTE:
A FULL WARNING
SYSTEM (VISUAL &
AUDIBLE ALARM)
FOR VEHICLE &
PEDESTRIAN
WARNING SYSTEM
STAIR - 1 STAIR - 2
PROVIDE GATE TO
RESTRICT ACCESS TO
BASEMENT.
PROVIDE GATE
TO RESTRICT
ACCESS TO
BASEMENT.
DROP OFF & PICK UP AREA
RAMP UP 1/12
5' - 0"53' - 0"
24' - 0"
6'
-
4
"
9' - 10"
88' - 5"
4'
-
0
"
21
'
-
9
"
67
'
-
0
"
96' - 6"
001
009
2
A36
5' - 0"6' - 7"24' - 0"
5' - 0"
101
A1
A1
5
1'
-
7
"
009
RETAIL - 1
2,294 SF INTERIOR
2,348 SF TOTAL
RETAIL - 2
2,647 SF INTERIOR
2,695 SF TOTAL
VESTIBULE
109 SF INTERIOR
155 SF TOTAL
202 SF
CAR ELEVATOR-2
GARAGE ACCESS
1,662 SF
A36
1
16' - 4"
PASSENGER LOADING ZONE
14
'
-
2
"
59' - 1"
43 CAROLINE
STREET
(CLANCY'S
TAVERN)
ONE‑STORY
ABUTTING
BUILDING.
HEIGHT: ± 20
FT (BASED
ON GOOGLE
EARTH DATA)
5'
-
0
"
16
'
-
2
"
ABUTTING
BUILDING
5
5 5
3
A1
A1
Room name
150 SF
101
1i
1t
R @ 7 1/2"20
CM
ROOM NAME
DOOR TAG
WALL TAG
WINDOW TAG
STAIR TAG
SMOKE DETECTOR
CARBON MONOXIDE
1' - 6"
1' - 0"
18" PULL SIDE
12" PUSH SIDE
ALL DOOR CLEARANCES
TYPICAL ALL DOORS
NOTE:
1. STENCIL THE FOLLOWING NOTE ON WALLS
ABOVE ALL SUSPENDED CEILINGS:
"FIRE BARRIER – PROTECT ALL OPENINGS."
•LETTERING SHALL BE NOT LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8-INCH STROKE AND SHALL
BE A CONTRASTING COLOR TO THE WALL COLOR.
•LOCATE STENCIL WITHIN 15 FEET OF THE END OF
EACH WALL AND AT INTERVALS NOT TO EXCEED 30
FEET, MEASURED HORIZONTALLY ALONG THE WALL
OR PARTITION.
2.PROVIDE 3-HOUR SPRAY-APPLIED
FIREPROOFING AT ALL COLUMNS:
Z-106 HY BY MONOKOTE, OR APPROVED EQUAL.
3.ALL WOOD FRAMING ON FIRST FLOOR TO BE
FIRE-RETARDANT TREATED LUMBER.
4.AT THIS TIME, ONLY THE BUILDING SHELL FOR
THE TWO RETAIL SPACES IS BEING CONSTRUCTED.
THE SPACES WILL BE SHEETROCKED FOR FIRE
PROTECTION, AND REQUIRED LIFE SAFETY SYSTEMS
WILL BE INSTALLED.
IT IS A VIOLATION OF THE LAW
FOR ANY PERSON, UNLESS
ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL,
TO ALTER AN ITEM IN ANY WAY.
IF AN ITEM BEARING THE SEAL
OF A LICENSED PROFESSIONAL
IS ALTERED, THE ALTERING
LICENSED PROFESSIONAL
SHALL AFFIX TO THEIR ITEM
THEIR SEAL AND THE NOTATION
"ALTERED BY," FOLLOWED BY
THEIR SIGNATURE AND THE
DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
PROJECT #
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
CR
O
N
A
N
D
E
M
P
S
E
Y
35
C
A
R
O
L
I
N
E
S
T
R
E
E
T
SA
R
A
T
O
G
A
S
P
R
I
N
G
,
N
Y
1
2
8
6
6
VERIFY AND CONFIRM ALL CONDITIONS AND/OR DIMENSIONS SHOWN PRIOR TO
COMMENCING CONSTRUCTION OR ORDERING MATERIALS. NOTIFY ARCHITECT OF
ANY INCONSISTENCIES FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH
CONSTRUCTION.
GENERAL NOTE:
86
T
u
t
t
l
e
S
t
r
e
e
t
,
D
o
r
c
h
e
s
t
e
r
,
M
a
s
s
a
c
h
u
s
e
t
t
s
0
2
1
2
5
T
e
l
:
8
5
7
-
2
6
4
-8
0
8
5
EXP: 06-30-2027
As indicated
5/11/2026 12:47:44 PM
FI
R
S
T
F
L
O
O
R
P
L
A
N
25-030
09-22-2025
DK
WC
A1
3/16" = 1'-0"1 FIRST FLOOR
3/16" = 1'-0"
DOOR CLEARANCES
FIRST FLOOR
STAIR0' - 0"
SECOND FLOOR12' - 0"
THIRD FLOOR22' - 0"
FOURTH FLOOR
32' - 0"
FIFTH FLOOR42' - 0"
PENTHOUSE52' - 0"
ROOF.63' - 0"
0 2'-0"4'-0"8'-0"
SCALE: 1/4" = 1'-0"
12
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
10
'
-
0
"
11
'
-
0
"
KEARNEY BLOCK
35 CAROLINE
RESTAURANT
TOP OF PARAPET64' - 7"
1'
-
7
"
CUSTOM CAST
PEDESTRIAN CAR
WARNING SYSTEMS
PEDESTRIAN CAR
WARNING SYSTEMS
TYPICAL FOR SWINGING DOORS NOT LOCATED IN DWELLING UNITS.
SWINGING DOOR SURFACES WITHIN 10 INCHES OF THE FINISHED
FLOOR, MEASURED VERTICALLY, MUST HAVE A SMOOTH SURFACE
ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR, PER
2009 ICC A117.1, SECTION 404.2.9.
3
4
1
2KEY PLAN Caroline Street
Pa
v
i
l
i
o
n
P
l
a
c
e
NOTE: WINDOWS AND DOORS
SHALL HAVE A ROWLOCK
MASONRY COURSE AT THE
HEADER. WINDOWS SHALL HAVE
PRECAST CONCRETE SILLS. SEE
DETAIL ON DRAWING A14.
NO PENETRATIONS THROUGH THE EXTERIOR WALL. ALL
VENTING IS THROUGH THE ROOF.
IT IS A VIOLATION OF THE LAW
FOR ANY PERSON, UNLESS
ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL,
TO ALTER AN ITEM IN ANY WAY.
IF AN ITEM BEARING THE SEAL
OF A LICENSED PROFESSIONAL
IS ALTERED, THE ALTERING
LICENSED PROFESSIONAL
SHALL AFFIX TO THEIR ITEM
THEIR SEAL AND THE NOTATION
"ALTERED BY," FOLLOWED BY
THEIR SIGNATURE AND THE
DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION
OF THE ALTERATION.
PROJECT #
DATE:
SCALE:
DRAWN BY:
CHECKED BY:
CR
O
N
A
N
D
E
M
P
S
E
Y
35
C
A
R
O
L
I
N
E
S
T
R
E
E
T
SA
R
A
T
O
G
A
S
P
R
I
N
G
,
N
Y
1
2
8
6
6
VERIFY AND CONFIRM ALL CONDITIONS AND/OR DIMENSIONS SHOWN PRIOR TO
COMMENCING CONSTRUCTION OR ORDERING MATERIALS. NOTIFY ARCHITECT OF
ANY INCONSISTENCIES FOR REVIEW AND APPROVAL BEFORE PROCEEDING WITH
CONSTRUCTION.
GENERAL NOTE:
86
T
u
t
t
l
e
S
t
r
e
e
t
,
D
o
r
c
h
e
s
t
e
r
,
M
a
s
s
a
c
h
u
s
e
t
t
s
0
2
1
2
5
T
e
l
:
8
5
7
-
2
6
4
-8
0
8
5
EXP: 06-30-2027
As indicated
5/11/2026 12:47:56 PM
BU
I
L
D
I
N
G
E
L
E
V
A
T
I
O
N
-
1
M
A
I
N
EN
T
R
A
N
C
E
25-030
09-22-2025
DK
WC
A8
1/4" = 1'-0"1 ELEVATION 1 MAIN ENTRANCE