Loading...
HomeMy WebLinkAbout20250583 9 Bingham St Area Variance Revised Plans 08.07.2026FRONT ELEVATION PROPOSED HANDRAIL REQ FOR 4 OR MORE RISERS METAL ROOF DUE TO 3/ 12 PITCH ON PORCH 2nd FLOOR 2nd FLOOR CEILING TOP OF WINDOWS 17'-0" ADDITIONNEW COVERED PORCH RIGHT ELEVATION PROPOSED 8'-0" NEW COVERED PORCH 30'-0" 4'-0" REAR ELEVATION PROPOSED 2nd FLOOR 2nd FLOOR CEILING TOP OF WINDOWS 17'-8" LEFT ELEVATION PROPOSED REAR STOOP REQ AT REAR DOOR MAIN HOUSE ADDITION MAIN HOUSE ADDITION 8'-0" MAIN FLOOR PLAN PROPOSED 19'-11" 1'-61 2" 5'-81 2" 13 ' - 4 " 13 ' - 3 " 17'-2" 9'-11" 9'-101 2" 6' - 8 " 2-8 LIVING ROOM 36" x 67" DH 36" x 67" DH 32 " x 6 0 " D H 7' 6 1/2" CEILING HT DINING AREA 9'-71 2" 31 " x 5 2 " D H KITCHEN 7' 7" CEILING HT FIXED DR 2-10 C.O. 25 " x 4 3 " D H 3-0 LAUNDRY 9' 1 1/ 2" WALL HT 7' 1 1/ 2" WALL HT (13)RISERS UP NEW COVERED PORCH 8' - 0 " 2' - 0 " STORAGE 6' - 1 1 " ± 3-0 2-8 30 ' - 0 " (1)CAR GARAGE 17'-0" 6' - 6 " 29 ' - 1 " 9-0 x 7-0 OVERHEAD DR ROOF OVERHANG BRACKET 5' - 0 " 3-0 3-0 MODIFIED EXISTING STAIRS TO CELLAR 20'-9" 3'-7" GUARD REQ IF PORCH > 30" ABOVE GRADE 2-8 STORAGE UNDER STAIRS STEPS UP AS NEC 16'-61 2" 12'-6" 2-6 6' - 8 " 2-6 36" MIN LANDING REQ 4' - 0 " 10'-0" 4' - 0 " 10'-0"6'-0" 50 CFM MIN EXHAUST FAN TO EXTERIOR SMOKE ALARM / CARBON MONOXIDE DETECTOR / ALARM (HARD WIRED) 60W EQUIV LIGHT FIXTURE HEAT DETECTOR (HARD WIRED) 9'-51 2" 4' - 1 " 2'-6" 3'-4" 2' - 3 12"5'-10" 13'-0" 4' - 1 " CANTILEVERED DECK ABOVE CANTILEVERED DECK ABOVE 3'-1" 4'-1" LANDING 12'-0" MAIN FLOOR PLAN EXISTING DOCUMENTED 5/19/26 BY: Y ENGINEERING, DPC 19'-11" 1'-61 2" 5'-81 2" 13 ' - 4 " 13 ' - 3 " 17'-2" 9'-11" 9'-101 2" 6' - 8 " 15'-7" 2-8 LIVING ROOM 36" x 67" DH 36" x 67" DH 32 " x 6 0 " D H 7' 6 1/2" CEILING HT DINING AREA 9'-71 2" 31 " x 5 2 " D H KITCHEN 32 " x 6 0 " D H 7' 7" CEILING HT FIXED DR 2-10 C.O. 25 " x 4 3 " D H 3-0 LAUNDRY 9' 1 1/ 2" WALL HT 7' 1 1/ 2" WALL HT COVERED PORCH (2)RISERS UP (13)RISERS UP UPPER FLOOR PLAN EXISTING DOCUMENTED 5/19/26 BY: Y ENGINEERING, DPC PRIMARY BEDROOM 36" x 67" DH 36" x 67" DH 32 " x 6 0 " D H BEDROOM 9'-10" 34 " x 6 0 " D H BEDROOM 32 " x 6 0 " D H 7' 7" CEILING HT 8' - 6 12" 6'-10" 13 ' - 5 12" BUILT INS 2-8 2-8 CLOSET CABINET 13 ' - 3 12" 12'-8" 4' - 4 " 7'-0" 5' - 0 " 2-82-8 CL O S E T 34 " x 6 0 " D H (13)RISERS DN 7'-0" 12 ' - 4 " UPPER FLOOR PLAN PROPOSED BEDROOM 36" x 67" DH 36" x 67" DH 32 " x 6 0 " D H 9'-10" 34 " x 6 0 " D H BEDROOM 8' - 6 12" 6'-10" BUILT INS 2-8 2-8 CLOSET CABINET 13 ' - 3 12" 12'-8" 4' - 4 " 7'-0" 5' - 0 " 2-82-8 CL O S E T 7'-0" 34 " x 6 0 " D H 12 ' - 4 " (13)RISERS DN 20 ' - 9 " EXPANDED BR AREA 4' - 0 " CANTILEVERED DECK 6-0 SLIDER 4' - 0 " 10'-0" CANTILEVERED DECK 5'-1" 6' - 7 12" ROOF BELOW 2'-2"14'-1" 4' - 7 " 11 ' - 1 " 13'-2" BEDROOM 5' - 1 " 8'-2" 12 ' - 4 " 10'-01 2" 16'-61 2" KITCHEN LIVING AREA DN 3'-1" 2-8 4'-81 2" 2'-10" 3'-1" 8'-51 2" 10'-0"6'-0" 4'-21 4" 2-8 2-6 HANDRAIL REQ 34-36" AFT 11'-11 2" 2-6 (188 SQ.FT. TOTAL) (REMAINS UNCHANGED) (REMAINS UNCHANGED) 9' - 0 " 6'-6" 3' - 1 " 50 CFM MIN EXHAUST FAN TO EXTERIOR SMOKE ALARM / CARBON MONOXIDE DETECTOR / ALARM (HARD WIRED) 60W EQUIV LIGHT FIXTURE 6-0 SLIDER (150 SQ.FT.) 2'-6" 2'-10" PARTIAL WALL (FINAL LAYOUT TBD) (204 SQ.FT) TR A N S O M W I N D O W 36" x 60" DH 17'-0" 36" x 60" DH 36 x 6 0 " D H 36 x 6 0 " D H VAULTED CEILING VAULTED CEILING FLAT CEILING AREA FLAT CEILING AREA VAULTED CEILING VAULTED CEILING PORCH ROOF BELOW 30 ' - 0 " 5' - 0 "