HomeMy WebLinkAbout20260627 Brook Rd Verizon Communications Facility Site Plan Site Compliance Report1
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
Verizon Wireless
Site Compliance Report
Site name - Saratoga Quarry
Site Name: Saratoga Quarry
Site Address: Brook Rd, Saratoga Springs, NY, 12866
Structure Type: Monopole
Report Information
Report Date: June 29, 2026
Report Generated by: Mamta Verma
Customer Contact: Rick Andras
Compliance Statement
Verizon Compliance Statement:Verizon Wireless is compliant with FCC rules and regulations in all publicly accessible
areas.
2
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
Contents
1. Executive Summary........................................................................................................................................................3
2. Antenna Inventory .........................................................................................................................................................4
3. Analysis...........................................................................................................................................................................5
4. Appendix A: Reference Information...............................................................................................................................6
3
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
1. Executive Summary
Verizon Wireless has contracted with Circet USA, an independent Radio Frequency consulting firm, to determine
if the proposed telecommunications facility is in compliance with Federal Communications Commission (FCC)
rules and regulations regarding RF exposure as defined in 47 CFR § 1.1307(b) and 1.1310. This document and the
conclusions herein are based on the information provided by representatives of Verizon Wireless which is assumed
to be true and correct.
All information used in this report was analyzed to determine compliance in publicly accessible areas, in particular
at ground level. The analysis evaluates the telecommunications facility with respect to the General
Population/Uncontrolled Maximum Permissible Exposure (MPE) limits. Circet USA has taken into consideration
the Verizon Wireless antenna system as well as any existing antenna systems at the subject location.
Verizon Wireless final antenna count is (9) antenna.
Based on the analysis, Circet USA has determined that:
Verizon Wireless is compliant in all publicly accessible areas with the FCC rules and regulations governing human
exposure to RF electromagnetic fields as described in 47 CFR § 1.1307(b) and 1.1310.
With the proposed Verizon Wireless antenna configuration in service, the composite exposure from this facility in
all areas at ground level will be less than 1% of the General Population MPE limit, or over 100 times less than the
maximum allowed exposure in publicly accessible areas.
4
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
2. Antenna Inventory
The table below contains data provided by Verizon Wireless representatives and/or gathered by
Circet USA personnel. This data was used to perform the RF exposure analysis.
Notes: Each row with the same number in the Antenna ID column references the same physical antenna. Power values provided by the client and used in the analysis
may be greater than what is initially deployed.
80% TDD Duty Cycle and 100% FDD Duty Cycle are used.
Ant ID Owner
Antenna
manufacturer Antenna model Mech. Tilt
(°)
Azimuth
(°)Height (ft) Frequency band
Elec. Tilt
(°)HBW (°) VBW (°)
Total
power
(Watts)
Gain
(dBd)
ERP
(Watts)
1 Verizon Samsung MT6433-77A 0 0 115 NR 3.7GHz 0 98 18 381.3 24.45 106228.55
2 Verizon CommScope NHH-65C-HG-R2B 0 0 115 LTE 700 2 65 8.7 80 14.85 2443.94
2 Verizon CommScope NHH-65C-HG-R2B 0 0 115 LTE/NR 850 2 60 7.7 80 15.15 2618.73
2 Verizon CommScope NHH-65C-HG-R2B 0 0 115 LTE AWS3 2100 0 63 4.7 400 17.65 23284.13
3 Verizon CommScope NHH-65C-HG-R2B 0 0 115 LTE 700 2 65 8.7 80 14.85 2443.94
3 Verizon CommScope NHH-65C-HG-R2B 0 0 115 LTE 850 2 60 7.7 80 15.15 2618.73
3 Verizon CommScope NHH-65C-HG-R2B 0 0 115 LTE 1900 0 63 4.7 240 17.65 13970.48
4 Verizon Samsung MT6433-77A 0 120 115 NR 3.7GHz 0 98 18 381.3 24.45 106228.55
5 Verizon CommScope NHH-65C-HG-R2B 0 120 115 LTE 700 2 65 8.7 80 14.85 2443.94
5 Verizon CommScope NHH-65C-HG-R2B 0 120 115 LTE/NR 850 2 60 7.7 80 15.15 2618.73
5 Verizon CommScope NHH-65C-HG-R2B 0 120 115 LTE AWS3 2100 0 63 4.7 400 17.65 23284.13
6 Verizon CommScope NHH-65C-HG-R2B 0 120 115 LTE 700 2 65 8.7 80 14.85 2443.94
6 Verizon CommScope NHH-65C-HG-R2B 0 120 115 LTE 850 2 60 7.7 80 15.15 2618.73
6 Verizon CommScope NHH-65C-HG-R2B 0 120 115 LTE 1900 0 63 4.7 240 17.65 13970.48
7 Verizon Samsung MT6433-77A 0 240 115 NR 3.7GHz 0 98 18 381.3 24.45 106228.55
8 Verizon CommScope NHH-65C-HG-R2B 0 240 115 LTE 700 2 65 8.7 80 14.85 2443.94
8 Verizon CommScope NHH-65C-HG-R2B 0 240 115 LTE/NR 850 0 60 7.7 80 15.15 2618.73
8 Verizon CommScope NHH-65C-HG-R2B 0 240 115 LTE AWS3 2100 0 63 4.7 400 17.65 23284.13
9 Verizon CommScope NHH-65C-HG-R2B 0 240 115 LTE 700 2 65 8.7 80 14.85 2443.94
9 Verizon CommScope NHH-65C-HG-R2B 0 240 115 LTE 850 0 60 7.7 80 15.15 2618.73
9 Verizon CommScope NHH-65C-HG-R2B 0 240 115 LTE 1900 0 63 4.7 240 17.65 13970.48
5
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
3. Analysis
Circet USA has included the Verizon Wireless antenna system at the subject location in the
analysis. All existing and proposed antennas are listed in the antenna table above. Engineering
assumptions were used when specific antenna or operating parameter information was not
available for the other existing collocated antennas (if applicable).
Using this data, software modeling using IXUS software was performed for all transmitting
antennas located at the site. Circet USA has assumed a 100% duty cycle and maximum radiated
power. The site has been modeled with these assumptions to determine the maximum potential
RF energy density at ground level. Circet USA
on the best available data.
As stated previously, based on this analysis, the calculated ground level exposure from the
Verizon Wireless antenna system alone is less than 1% of the General Population MPE limit.
Keep in mind that the FCC did not arbitrarily establish their own standards but rather adopted
the recommendations of national and international organizations such as the National Council
on Radiation Protection and Measurements (NCRP), the American National Standards Institute
(ANSI) and the Institute of Electrical and Electronics Engineers (IEEE). These
recommendations were developed by expert scientists and engineers following extensive
evaluation of the potential biological effects from RF exposure. The FCC MPE limits are based
on thresholds for known adverse effects, and they were designed to provide a substantial
margin of safety. There is a safety factor of 50 built into the General Public MPE limits, and the
predicted Verizon Wireless exposure levels are over 100 times below these very conservative
limits.
In cases where such compliance exists, the subject of electromagnetic field safety is preempted
by the Telecommunications Act of 1996, which states: “No state or local government or
instrumentality thereof may regulate the placement, construction, and modification of personal
wireless service facilities on the basis of the environmental effects of radio frequency emissions
to the extent that such facilities comply with the (Federal Communication) Commission’s
regulations concerning such emissions.”
The graph below provides a visual depiction of the rather insignificant electromagnetic field
exposure contribution from the Verizon Wireless antenna system out to a distance of 500’ from
the base of the structure. This portrays how low the Verizon Wireless contribution is when
compared to the General Population MPE limit.
6
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
4. Appendix A: Reference Information
FCC Rules & Regulations
All information used in this report was analyzed as a percentage of the MPE limits as detailed in 47 CFR §
1.1310. The calculated power density at each sample point divided by the limit at each calculated frequency
provides a result in % MPE. Summing the calculated % MPE from all contributors provides accumulative
% MPE at a particular sample point. Wireless carriers use different frequency bands with varying MPE
limits; therefore, it is useful to report results in terms of % MPE as opposed to power density.
All results were compared to the FCC radio frequency exposure rules as detailed in 47 CFR § 1.1307(b) to
determine compliance with the MPE limits for General Population/Uncontrolled environments as defined
below:
Two Classifications for Exposure Limits
Occupational – Applies to situations in which persons
are “exposed as a consequence of their employment”
and are “fully aware of the potential for exposure and
can exercise control over their exposure”.
General Population – Applies to situations in which
persons are “exposed as a consequence of their
employment may not be made fully aware of the potential
for exposure or cannot exercise control over their
exposure”. Generally speaking, those without significant
and documented RF Safety & Awareness training would
be in the General Population classification.
Environment Classification
Controlled – Applies to environments that are restricted
or “controlled” in order to prevent access from members
of the General Population classification.
Uncontrolled – Applies to environments that are
unrestricted or “uncontrolled” that allow access from
members of the General Population classification.
7
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
The MPE limits defined in 47 CFR § 1.1310 and utilized in this analysis are outlined in the table and diagram
below:
Limits for Occupational/Controlled Exposure
Frequency Electric Field Magnetic Field Power Density Averaging Time
Range Strength Strength (S)|E|2, |H|2, or S
(MHz)(E) (V/m)(H) (A/m)(mW/cm2)(minutes)
0.3-3.0 614 1.63 (100)* 6
3.0-30 1842/f 4.89/f (900/f2)* 6
30-300 61.4 0.163 1.0 6
300-1500 f/300 6
1500-100,000 5 6
Limits for General Population/Uncontrolled Exposure
Frequency Electric Field Magnetic Field Power Density Averaging Time
Range Strength Strength (S)|E|2, |H|2, or S
(MHz)(E) (V/m)(H) (A/m)(mW/cm2)(minutes)
0.3-1.34 614 1.63 (100)* 30
1.34-30 824/f 2.19/f (180/f2)* 30
30-300 27.5 0.073 0.2 30
300-1500 f/1500 30
1500-100,000 1.0 30
f = frequency in MHz
* =