HomeMy WebLinkAbout20260573 23 Division St. Mechanical Install & Signage PlansNORTH 18 MERICAN DUCT VEN11LATION
IMF EN SOLUTIONS
I N C O k P O k A T E a
SFI SERIES
Single Forward Curved Inline Duct Blowers
As part of an HVAC system SFI Duct Blowers will not "surge", "hunt". or'stall,
Quiet forward curved blowers operate at 1A the rpm of other inline solulions.
SFI is an outdoor series.
Intake Hood
(Snorkel Included) FEATURES
SFI SERIES
Heavy duty, insulated Indoor
or Outdoor Applications
rNABS cer[Hlos that the 200 R 9200 Serlos shown
aln� herein are Ilconeed to bearihe AAACA Seal, c
The radngs shown era hasad an tuts and
procedunapmrkwnwdInaccordancewith AMCA
Pubk
requir allana till 8 9and campy wllh the
raqulnmrnaa of A the MCA Cartlllad Ratings Inrel'tek
Pr°gremrr' 705
PERFORMANCE SPECIFICATIONS
• Wheel Diameters: 9" through 15"
• CFM: Approximately 500 to 4,400 CFM in a single blower.
• Constructed from cold rolled steel, with grey baked on powder coat.
The outdoor unit uses protective galvaneal steel under the powder coal.
• Forward Curved blowers operate at low RPM For law noise levels -
Heavy duty ball bearings suitable for-65' F to +25W F
• Keywayed shafts both ends for clockwise or counter clockwise rotation.
• Saddle type motor mounting platform provides extended belt tension
adjustment range on all models.
EID0
0.5
786
0.12
5.2
SFIS
1 - 115230Y
MHP.56 FR
575-862
110a
0.125
573
0.12
3.3
SFl5-3PH
3 - 2301460
11a0
a-5
616
0-2
&
13a0
a.5
051
0.20
6.0
1B00
0.125
642
0.3
7-8
SFl7
1 - 515+230V
1HP. 56 FS
E40 - 887
230a
0-125
796
0.56
12.4
SFl7.3PH
3. 23W460
190a
a.5
622
0.45
16.3
2100
0.5
066
0.56
12.1
2600
0.125
620
0.43
6.3
SF19
1 - t15+2a0Y
32aa
0.125
737
0.75
12
1 HP 56 FR
575 - 862
22aa
a.5
746
0.46
9-6
SFl6-31AH
3 - 23W460
230a
0-5
759
0.51
10.4
3000
B60
0.BB
3600
0.125
7.2
BFl9
] - 11 30Y
4100
0.125
492
0.84
RA
1 •112HP, 56 itH
431 - 616
##00
0.125
525
1.04
10.7
SF19-3PH
3. 2301460
3100
0-5
532
0.62
se
#400
0-6
596
1.23
12.1
INDUSTRIES SERVED
• Commercial HVAC
• Ventilation
Heating
Cooling
Construction
TYPICAL APPLICATIONS FOR OUR INLINE BLOWERS
Power rating (BHP) does not include
transmission losses. Perkxmance certified
is For Instahadon type B; Free inlet. Ducted
outlet. Performance ratings do not include
the effect of appurtenances (accessories).
An Inllne make-up air solution for eases where a rooftop curb mouriled When the application requires an air mover in a duct system located
solution is not available. in a Ceiling space.
As an air moving module For systems built up with other components Redistribution or recirculation of air in a work space.
such as heatinglcooling coils. Interlocked with entry doors to prevenl enlry of cold outdoor air into
• Noise sensitive areas - the low rpm forward curved wheel typically retail sales space and thus greets customers with warmth.
radiates less vibration than higher rpm backward inclined wheel Bathroom/ rest room exhausl - one duct blower serving multiple
solutions. intakes.