Loading...
HomeMy WebLinkAbout20260521 Henning Road Verizon Utility Pole NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Karen Cavotta Karen D’Andrea Leslie DiCarlo Jeff Pfeil Geoff Wood Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20260521 Henning Road Verizon Utility Pole Adj to Henning Road Saratoga Springs, New York 12866 involving Architectural review of collocation of a utility pole and wireless equipment in the right of way within the Rural Residential (RR) District, tax parcel #166.61-3-25, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on July 22, 2026:  Approve the plans as submitted or shown on the attached Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and actual work begun. Record of vote: motion to approve made by T Ehinger, seconded by G Wood passed 6-0 In favor: T Ehinger, R DuBoff, K D’Andrea, K Cavotta, J Pfeil, G Wood Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent 13# NORTH ORIENTATION N 7l1. NOR4 H ORIENTATIO'J ESTABL ISId ..0 N BY COMPASS OBSERVATION!. EDGE OF EXISTING—., PAVEMENT IIF1 1` C' O 41 o y. F its r ! A t w M C. Ir 1 EXISTING OVERHEAD WIRE (TYP) d .. . yf) # / t + C' PROPOSED VERIZON WIRELESS EQUIPMENT ON PROPOSED UTILITY POLE. NEW POLE TO \ t REPLACE EXISTING UTILITY POLE #NM 17/VZ 15 \ 1 e r s ir; do ` — EKSTI Nt U11LITY POLE `TIP) R NOTE: SITE IN- ORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING CONSULTANTS, GEOLOGISTS & LAND SURVEYORS D.P.C., OIJ 11 /10/25. 1 SITE PLAN 1" - 8"" (11x17 S12E) 1- = 40' (22x34 S17E) EXISTING UTILITY POLE TO BE REMOVED & REPLACED EQUIPMENT PLAN C-1 SCALE: 3/4' = 1•-0" (11x17 SIZE) 1 1/2" - (22x34 SIZE) PROPOSED VERIZON WIRELESS EQUIPMENT SHROUD WITH PROPOSED RRH AND ASSOCIATED EQUIPMENT SEE DETAIL 5/C-3) PROPOSED FUJITSU PASSIVE - FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD PROPOSED VERIZON WIRELESS 1" FIBER CONDUIT PROPOSED 1-1/2" CONDUIT FROM SECONDARY TO METER) PROPOSED UTILITY POLE 3 SHROUD PLAN VIEW SCALE; 3/4" = 1'-0" ('tx,7 SIZE) 1-1/2" = 1•-0" (22x34 SIZE) PROPOSED #2 VERTICAL GROUND 1-1 /2" FROM RY TO METER) PROPOSED METER PROPOSED #2 VERTICAL GROUND PROPOSED 100A LOAD CENTER DPOSED 1-1 /4" RISER FOR AC C`I IITq Tn gHRni In GUARD FOR ANTENNA verizon 175 CALKINS ROAD 11 ROCHESTER, NY 14623 Tectonic PRAC"i SOMC . Te,_tone E4%MWA0ComAwta, 090bolb ! Land %-wtom, "-.- Project ca":-tact Into 36 8r-tlwh Amerizon BlvC Phorn. '5'8) 7,43-1630 SJ;te 10' {900) 82.9-6531 Latnam, NY 12110 »wwAezt3mcengincerngxom NO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP kin 11A= ICCI IC 0 05/G6/26 FOR REGULATORY 1 05/D9/26 ADDED PAINT NOTE pF A` j UNAUTHORIZED AL =RATION CR ADDITIONS TO A PLAN: BLARING THE SEAL OF A LICENSED ENGINEER OR LAP:D SURVEYOR IS A VIOLATION OF SECTION 7209 SUED - VISION 2 OF THE NEW YORK STATE EDUCATION u.w. COPIES OF THIS DOCUMEN' VlrTHOUT A FACSIMILE 0= THE SIGriATLRE AND AN: ORIGINAL EMBOSSED SEAL OR OR;GINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR L-.'JD SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES- 0 1 ORIGINAL SIZE IN INCHES 22x34 FORMAT) 0 ORIGINAL SIZE IN INCHES 11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE IDS: 17612418 MDG#: 5000993724 511E ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE SITE PLAN & EQUIPMENT PLAN SHEET NUMBER Cw l SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450) 3. REPLACE SPAN OF NEUTRAL TO P18 1MTH 250' OF 1/0 TPX. 4. ATTACH TPX AT 31'6". 5. REPLACE SEC BRACKETS (NG 10-101 FIG 5). 6. REPLACE PRI DG (NG 3-105). 7, INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. LICENSE APPLICATION BROOD & RIDDLE/MDG:5000993724 WORK REQUEST ##30352102 t F 4 ...• I• ti z • 1 EXISTING POLE PHOTO C-2A SCALE: NTS EXISTING PRIMARY ELECTRIC 34.0'± AGL \ TOP OF EXISTING UTILITY POLE 33.2'± AGL EXISTING PRIMARY ELECTRIC 31.3'± AGL EXISTING DOWN GUY WIRE IX 30.0'± AGL EXISTING PRIMARY ELECTRIC LINE TO BE RELOCATED PER NATIONAL GRID REQUIREMENTS SEE 3/C-2A) EXISTING PRIMARY ELECTRIC CROSSARM TO BE REMOVED & REPLACED PER NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) R_ EXISTING SECONDARY ELECTRIC LINE TO BE RELOCATED PER f NATIONAL GRID REQUIREMENTS EXISTING SECONDARY SEE 3/C-2A) 26.3'± AGL EXISTING DOWN GUY TO BE REMOVED & REPLACED EXISTING COMM LINE TO BE r1h EXISTING FIBER LINE RELOCATED (BY OTHERS) 22.7 ± AGL EXISTING DOWN GUY WIRE EXISTING COMM LINE TO BE 22.7'± AGL RELOCATED (BY OTHERS) EXISTING COMM LINE 22.0'± AGL EXISTING UTILITY POLE NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE STREET SIDE 2 EXISTING UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (22x34 SIZE) 19" TOP OF PROPOSED UTILITY POLE REPLACE PRIMARY 38.5 ± AGL / CROSSARM WITH NG 9-450 RELOCATED PRIMARY 36.5'± AGL- NEW/REPLACEMENT DOWN GUY WIRE 35.2'± AGL NEW REPLACEMENT SECONDARY 31.5'± AGL RELOCATED FIBER LINE MR-) 25.0'± AGL r rik RELOCATED DOWN GUY WIRE % 25.0'± AGL 0RELOCATED COMM LINE 24.0 ± AGL REPLACE PRI DG (NG 3-105). INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE REPLACE SPAN OF NEUTRAL TO P18 WITH 250' OF 1/0 TPX. ATTACH TPX AT 31'6". REPLACE SEC BRACKETS (NG 10-101 FIG 5) COMM/FIBER REATTACHMENTS TO BE DONE BY OTHERS (BY OTHERS) EXISTING UTILITY POLE NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE i STREET SIDE 3 PROPOSED UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (2204 SIZE) verizon 1 175 CALKINS ROAD ROCHESTER, NY 14623 la Tectonic FRACMAL sousnmca. Tat* m EmOw" Co mAmts, Codogisr i lad Uwwp s, Q.P.C. Proj. ? Gamut Info 36 British Amorleon Blva. Phor: (518) 783-1G3.9 Suiv te 101 800 829-6531 Latham. NY 12110 www.to&-onicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP Alf% r% ATC ICCIIC 0 05/ 06/26 FOR REGULATORY 1 06/ 09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIGINAL SIZE IN INCHES 22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES 11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 MAKE READY SCOPE OF WORK C- 2A NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. PROPOSED 4G ANTENNA SEE DETAIL 1 /C-3) PROPOSED POLE TOP ANTENNA MOUNT (SEE DETAIL 1 /C-3) INSTALL RF "CAUTION" SIGNAGE 2't BELOW PROPOSED ANTENNA (SEE DETAIL 4/C-3) PROPOSED WEATHERHEAD FOR POWER CARLON P/N: E99SH-CAR OR APPROVED EQUAL) PROPOSED COAX CABLES TO ANTENNAS IN 4" MAX U-GUARD PROPOSED MOPT TERMINAL - BY OTHERS) PROPOSED LC/UPC BIDI RUGGEDIZED FIBER - JUMPER FROM THE PROPOSED MOPT TERMINAL TO PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE WITHIN 1" CONDUIT PROPOSED VERIZON WIRELESS - EQUIPMENT SHROUD WITH PROPOSED RRH & ASSOCIATED EQUIPMENT COMMSCOPE PN: SSC-760249586X1 X OR EQUAL) (SEE DETAIL 5/C-3) PROPOSED 1-1/4- PVC RISER FOR - AC CIRCUITS TO SHROUD PROPOSED EATON BRP12B10OR LOAD CENTER OR APPROVED EQUAL (SECURE TO POLE USING UNISTRUT OR APPROVED MANUFACTURER RECOMMENDED HARDWARE) PROPOSED RF "INFORMATION" - SIGNAGE (SEE DETAIL 4/C-3) PROPOSED METER MILBANK P/N: U2048-RL OR-/ APPROVED EQUAL (SECURE TO POLE USING ERICKSON SERIES PBAL MOUNTING BRACKET OR ELECTRIC COMPANY APPROVED EQUAL) TOP OF PROPOSED ANTENNA 41.7'f AGL q PROPOSED ANTENNA- ---- --- -- - - 40.7'f AGL TOP OF EXISTING UTILITY POLE 38.5't AGL MIN EXISTING PRIMARY 36,3't AGL EXISTING SECONDARY 31.5'± AGL PROPOSED 1-1 /2" PVC RISER FOR POWER EXISTING GUY %"v'IRE 75.Ci't AGL EXISTING FIBER 25.0't AGL EXISTING C01/IMUNICATION 4.0'+ AGL BOTTOM OF PROPOSED MOPT TERMINAL21.7'f AGL PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD Y2 C-2E BOTTOM OF PROPOSED EQUIPMENT 12.0'f AGL (MINIMUM) BOTTOM OF PROPOSED LOAD CENTER 10.0't AGL (MINIMUM) BOTTOM OF PROPOSED METER 8.0't AGL (MINIMUM) BOTTOM OF PROPOSED RF SIGNAGE 8.0't AGL (MINIMUM) EXISTING UTILITY POLE PROPOSED HIGH IMPACT - PVC CABLE COVER (BLACK) EXISTING G)\ADFi 1 UTILITY POLE ELEVATION 28 SCALE: 3/16" = 1'—u" (11x17 SIZE) 3/8" = V-0" (22 x34 SIZE) EXISTING GRADE 0.0'f AGL PROP( TERMINAL (E PAINTING NOTE: ALL PROPOSED EQUIPMENT SHALL BE PAINTED BROW XISTING FIBER LINE XISTING COMIM LINE POSED VERIZON WIRELESS U-GUARD (CABLES FROM I TO ANTENNA) POSED LC/UPC BIDI RUGGEDIZED R JUMPER FROM THE PROPOSED IT TERMINAL TO PROPOSED FUJITSU 3SIVE FIBER ENCLOSURE POSED VERIZON WIRELESS EQUIPMENT OUD (COMMSCOPE PN: SSC-760249586X1 X EQUAL) (SEE DETAIL 5/C-3) POSED 1-1/2" CONDUIT OM SECONDARY TO METER) OPOSED RUGGEDIZED FIBER JUMPERS TO Hs AND MMUs IN THE SHROUD (TYP OF 2) OPOSED EATON BRP126100R AD CENTER OR APPROVED EQUAL IN OPPOSITE SIDE OF POLE) OPOSED 1-1/2" LIQUIDTIGHT ETER TO LOAD CENTER) PPOSITE SIDE OF POLE) OPOSED METER MILBANK P/N: 048-RL OR APPROVED EQUAL (SECURE POLE USING ERICSSON SERIES PBAL UNTING BRACKET OR APPROVED EQUAL) EXISTING UTILITY POLE ELEVATION DETAIL 2B SCA'_L: 2" = 1'-0" (11x17 SIZE) 1" - 1'—O" (22x34 SIZE) verizon i 75 CALKINS ROAD IitPr)rrESTER, NY 14623 i flectonic AmuL,SOLUTIoR&EXUP"ON LS.RVICE. T.etd E/+okiew10 Cenartw* Gedogletr t Lane 5lrwyon, Q.P.C. rrojsct Cc^loci info 36 bnt%eh American 81vc. Phore- (5'8 783-1G3J S J'te 101 ,800 829-6531 Lulhom. NY 12110 www.tectoricengmeenng.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP P kin MATT Icc11c C 05/06j26 FOR REGULATORY 1 0o/C9/26 ADDED FAINT NOTE UNAUTHORIZED ALTERATION OR ADDIT5ONS TO A PLAIT SEARING THE SEAL OF A LICENSED ENGINEER OR LAND LRVEYOR IS A VIOLA"ION OF SECTION 7205 SUED -VISION 2 OF T-Ic NFiV YORK STATE EDUCATION L' IV, COPIES OF THIS DOCUMEM WITHOUT A FACSIMTF 0= THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR ZED INK OF THE PROFESSIONAL ENGINEER OR L-.ND SURVEYOR. SHALL NOT 3E CONSIDERED V UD COPIES_ 0 1 ORIGINAL SIZE IN INCHES 22x34 FORIVAT) 0 ORIGINAL SIZE IN INCHES 11 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE POLE ELEVATION & DETAIL SHEET NUMBER ANTENNA (JMA P/N: CX160M1236—BF22) IA MOUNT SLEEVE (GIMBAL) ALFAB P/N: 900070) OLE MOUNT BRACKET CONCEALFAB P/N: 007951 R APPROVED EQUAL) TILITY POLE 0 TO tJE VERIFIED IN FIELD POLE —TOP ANTENNA MOUNTING 3 SCALE: %T3 I` A CAUTION A Transmitting Antenna(s) Radio frequency fields beyond this point MAY EXCEED the FCC Occupational exposure limit. Obey all posted signs and site guidelines. Call Verizon at 1-800-264-6620 PRIOR to working beyond this point. Site ID/ PSLC: verizon •` ACTIVE COMMUNICATION EQUIPMENT u1+JIUYAPR0004t W74i M FT FfOtR2r31iTJILA>tD R V1ERTtf,•1 POMP VON%AkT[hM BY VT7<AM DWOWOMT MTR} OR CALL v [ Iambi V nRE'. E 55 rOR PMR a•aTT001M V44E EVERAPPROACHW# TrViA1ao" _rt 1lOKITIUTALAtq-FT VUMCAI PIAAK CA- L tEF. Z0M WI R 3 S FT 1-I114l- 4QG FRl01l To CFfrtSTlr,G : C _hVEGT :'C- NOTE: 1. CONTRACTOR TO FURNISH AND INSTALL PHENOLIC LABEL APPLIED TO LOAD CENTER. 2. ATTACH R:Y "CAUTION" AND "INFORMATION" SIGNAGE TO FACE OF UTILITY POLE USING 1' r WOOD SCREWS. 3. RF SIGNS ARE APPROXIMATELY 6"0.5" IN SIZE. PROPOSED SIGNAGE SCALE: NTS POLE MOUNTING BRACKET — ERICKSON P/N: PBAL-12 OR APPROVED EQUAL) (TYP OF 2) e r -mil p 1p- 1 /4%1" WOOD SCREW TYP OF 4/BRACKET) S.S. 1/4"-2Ox3/4" CARRIAGE BOLT, FLAT WASHER, & NYLON LOCK NUT INCLUDED WITH BRACKET) PROPOSED METER SOCKET, MILBANK P/N/ U2048—RL (OR APPROVED EQUAL CONFORMING TO UTILITY COMPANY STANDARDS) METER MOUNTING DETAIL C-3 SCALE: NTS Metro Cell Solutions COMMSC- PE SSC-760249586X1X MV2 Micro Radio Concealment Enclosure Universal Single Part Number Radio Enclosure Introduction One pale mou led Ratio Er c i . - •, re fr r a U ywr radio moons under a siroE Dan r, UiTlt er Hpfty contigurabde - swports varyrng conrigurations with a unhwwl mounting t solution Aesftlicaa0F awwad trout ` r. Accepts Rados Iron: • Ericssw radios SSC-760249586EIX Nokia radios SSC-760249586N i X Samsung ra(hos SSC-760249586S 1 X Th= raoic __. ceairrler! e :cf^_ silplsu-e 1= deed to coriia +ea! smaj: cell -e ni " Jr-Te'd 10 wisl 1A MCiiJ) LOT..(C:C. i)1)., iS'_ _ Ili Al. --tJ'CS 81i wd ai vale replan ernerlts wrterc ,; _ :il Impact tt desired- UniQue, ant-.emaI internal rr•wunting s-,s,em Can he k;tted with Rec6-5erz CorrrnScoCe diF.wexers and jumpers System Dimensioning & Configuration i•__ ..-.- n-! -.!..i-. -iti •=i. ll«'".. :-rtr-, •tJ jr .i.;F. ri+i;,i .._ , .C.. :.. its•. 1+._'; ._ i- 1041b f43_+]I with rip fifdC efx:,QFMrY. ,-'I•.; S;:t--, ;`.,i'4 Approx 479tt 1276kgliciytoeded' (maxi weipW vaned on oofilguraeon LAn. ,, Max f..:,ilrCattle Poia 00 2.5ira85 in 00 by ciarnIpr4 (Lwgrr dionew pales by steell bardtng) Mth het ded MWr&V kt) Up to 121n DID Wood Ada with irm:Jitded 511l- ftreaded rod for ttr k* booing UV-resntao powder eoaL Vanouc eako o0o is a, ailae!a Finish 'I- for Ligm Gary. -Y for Green -3- for 84m*, --C for Brown W fcw Fa)rfax Brown -F Federal Park Brown. 'T for hietaa"c SNw "W for W hte Bik-A 1-2) 2' Trade Sire Knockouts Paver: Fiber input Corduii Bat: (2) I Trade Saa KnockocRs Top: (2 ) 2' Trade Size Knockouts MC-SP-RENT-21-001-M NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. UTILITY POLE - r'rCUt-UJ V Ghi t UN Dlzr- I LE ELECTRIC PANEL OR APPROVED E PROPOSED 1 /4%20 3/4" LONG BOLT (TYP OF 3) PROPOSED P1000T — UNISTRUT 6" LONG TYP OF 2) PROPOSED 1 CHANNEL NUT (TYF PROPOSE[ L 3 LOAD CENTER MOUNTING DETAIL SCALE: 4- = 1'-0" (11x17 SIZE) 1•-0" (22x34 SIZE) Metro Cell Solutions COMMSC,. PE Ericaeon CordiOurations 2) RRU1 VRRU!32R212s44154s2&4478 b (i) PSU AC OZW unim 118843 or 4449 Dual Band RRU 6 t2) PSU AC 02'Oa units 1) 9843 and (1) 4478 & (3) PSU AC 02V units 1) 4415_ (1) 444{1 wid (1) 220%440x i (3) PSU AC 02'DB units 1) 4455 and (1) •44413 d. 4 3) PSU AC 02.1% :slits 1) 4440 and (2) 220x-440s 8121 PSU AC 0204 Lauts Up to (61 Zn&K22052206 or 4402 440B radios 1) 4415 or 4426 radea and (1) 220x$440x a (1) PSU AC 02i08 I'Li tine Corrtpatibiltty for plot 320W C-Band Radio '• 11 r 8863 a--.J I 1 I cN S-. a•r 11) 444y (4 ) PSU ACO8,11) (1) :SOX 19=-43 811) Raycap se "PTease e Ccrrtnscgpe for additionaf wriigurabom - sa--m Co"Norrad— 01 or (2) 70Q'1l50 32M oval bard radio. t 1 r RT4401-48A CBRS radio. (1) RT2201- 46r1 LAA rA io, 0 l c1r (2b Dots 2 dk W DC rectifier. (1) SOX 1 o2f Q4W SDx 1426T-43 and (1) Raycep e 11) AWS+PCS AWS.'PCs 32OW dual band rode 11) RT4441.4aA CBRS radio. 01 RT2201j46A LAA radio, (1) Debts 2.0kW DC rectifier, (1) SOX11i260-43r SDX1926T- 43 and (1) Rsycao 111 AWS-PCS or 7W.'85O 32OW duo ber-4 radio. 0116OW dual band radio (1) RT4401-48A CBRS radio. (1) RT2201-46A LAA radio. (1) or (21 Deu 20kW DC Racko, Cow"Itibil-dy rtcilf w. t t l SDX 1926U-43r SDX192UT-43 arxi 11) Raycap SSC-760249S86XIX . 11) or (2) 16OW dual band ratbm (1) RT4401-46A CBRS radio. (1) RT-701 -6A LAA todlo. (1) or iZ) Deka 2.OkW DC rechW (1) 9DX 19260-4N SDX 1926T-4 3 t 1 ! Rayow PifCa-4ns--qr1r, rrprrsar AhV roradxfirtr:ar CO 5gnf ildOf s- Nokia Coefiprodons 14) A scale Micro rziaim 12) Dual Band Radios- 7&)VV and 320W phis tschfws S, upporfed dual band radios. AHFiA " AHFIS "AHFIC '-AHLBA "AP48C.A "AHRCC "Al4 BBA supported Rectifiers, Dolts " GE "CCI "Ndur FPAE Pk; arrtr see Cormrrscnpr+ re6paisenri im far additional cn6gtmatiorss- tf es- os.re Ac runw mho Vo eornsa,c warts "=MI i asc.:- as.v-.az-r•rscx-f rs>•_i.r:.c•v 3.:a,: Ervvclt: car.:CrxprWaare C3r.-s-_uor D M4e - llwx to -.SOX Mloc 43. 3Ct t?2CT.[1 E,-:;, as rrrye: :oormwwn 0"W 194W t f w OF., rink reCW%M a CCI .screres, chi tecottM OR tle FPAE-acomwa.- rumor see rrnee cr.e r0PT2W 0&V* to dea t x' 0W.4es i0Q-- -$ -roi LVII Glra. '.r +a Greer: -3- yr e.KA -4- F anfar erc•rt. T- F. eoe•a Pee sMW&. T tar Tar ''Al"r i x MC- SP-REMI-21-003v04 r EQUIPMENT SHROUD DETAILS S•.. l,': NTS SHOWN MOUNTED ON AN g'o POLE CLAMP. STRAP. AND THRU BOLT OPTIONS s. 0 , t3.0 , l jI ( 2) 2 TRADE SIZE KNOCKOUTS FOR CABLE ENTRY/ EXIT ( CROSS CUT RUBBER GROMMETS INCLUDED) T-`• — RJLLY VENTED WITH GR487 COMPLIANT PERF PATTERNS tr f . J i UNIVERSAL POLE—? REMOVABLE 24_ Ll MOUNTING BRACKET Pi4NEL ACCESS 3- 3 di 777, y t- 3048. ETAtitPE? RESISTANT LATCH f ." _...Y-... WITH PADLOCK HASP K 7' TRADE SIZE KNOCKOUTS 7 TRADE SIZE KNOCKOIJk, TAMPED. RESISTANT MTO SCREWS 4. 0.— r-• •-•• SSC-760249%6X1X 3: 5747 11{ i METROCELL RADIO CONCEALMENT 6.r. V.E;: A 1 CoMMSCC*APE I— -- - --- verizon1 175 CALKINS ROAD I ROCHESTER, NY14623ectonicPRArnuu SOLUTlottls. axatrr ON LL5111MCL Tectonic Enlmav ig Conu *-(t , Geologists • tmd Suvgors, D.P-C. Frnj•ct Cup-focf Info 36 86tish Amerl=n Blva. Fhone: (5'f3 783-1630 Suits 101 ( 800 829-6531 Latham. NY 12110 www.tectomicengineen-ng.comWO NUMBER DRAWN BY REVIEWED BY 12861.115 LP I MP NO. DATE ISSUE 0 05/ 06/26 FOR REGULATORY 1 06/ 09/26 ADDED PAINT NOTE I UNAUTHORIZED AL ERATION uR ADDI?!ONS TO A PLAN BEARING THE SEAL OF A LICENSED EfGINEER OR LAND SLR'v? YOR IS A VIOLATION OF SECTION 7209 SLED VISION 2 OF THE NEW YORK STATE EDUCAi1ON LA'r1'- COPIES OF THIS DOCUMENT yi1THCUT A FACSIMILE OF THE SIGNATURE AND AN ORIGIMA'_ -EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAUD SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 01 1 ORIGINAL SIZE IN INCHES 22x34 FORI'',: AT) 0 ORIGINAL SIZE IN INCHES 111 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866