Loading...
HomeMy WebLinkAbout20260577 Excelsior Ave Apartments Exterior Modifications Revised Application 07.23.2026Revised 12/2025 APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRB for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 12/2025 Revised 12/2025 Request for extension of current approval Identify date of original DRB approval: ______________Current expiration date: ________________ Org. App. No. ____________ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure (4 units +) -Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? No  Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Board. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Revised 12/2025 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Board for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRB will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Board will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Board may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/ quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Board responsibilities may be found in the City’s Unified Development Ordinance available in City Hall and on the City’s web site at https://ny-saratogasprings.civicplus.com/DocumentCenter/ View/17803/Full-UDO Revised 12/2025 City of Saratoga Springs OFFICE OF PLANNING AND ECONOMIC DEVELOPMENT FEES - 2026 Application to City Council FEE Comprehensive Plan Amendment Zoning Ordinance Amendment Planned Unit Development (PUD) Amendment $1,800 + $300/acre $800 + $300/acre $800 + $300/acre Application to Zoning Board of Appeals FEE Use Variance $1,400 + $75/app Area Variance - Residential (1 & 2 Family) $350/1st var + $75/app + $150/ea add variance Area Variance - 3+ Family and Commercial $1,000/1st var + $75/app + $200/ea add variance Interpretations $650 + $75/app Post Work Application Fee Application Fee x2 + $75/app Variance Extensions 50% of Application Fee + $75/app Application to Design Review Board FEE Demolition Residential Structures - 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $500 $75 Façade Change - removal/addition of windows, doors, $150 Addition or new construction $300 Approval Extension 50% of application fee 3+/Multi-Family, Comm, Mixed-Use Principal or Accessory Structure Materials Change - roof, windows, siding, paint color $150 Façade Change - removal/addition of windows, doors, $150 Addition or new construction $650 Approval Extension 50% of application fee Post Work Application Fee Application Fee x2 Application to Planning Board Special Use Permit $1,200 + $75/app Temporary Use Permit $500 Special Use Permit - Extension $400 Special Use Permit - Modification $550 + $75/app Site Plan Review - incl. PUD Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non-Residential / Mixed-use $800 + $150/1,000 sf (Non-Res) + 250 unit (Res) Administrative SPR Residential $400 Non-Residential / Mixed-use $800 Extension Residential $250 Non-Residential / Mixed-use $350 Subdivision - incl. PUD Sketch Plan $400 per sketch Preliminary Approval Residential: 1-5 Lots $700 + $75/app Residential: 6-10 Lots $1,100 + $75/app Residential: 11-20 Lots $1,450 + $75/app Residential: 21+ Lots $1,800 + $75/app Residential - Extension $350 Final Approval Residential $1,550 + $200/lot + $75/app Non-Residential $2,400/lot + $75/app Final Approval Modification Residential $400 + $75/app Non-Residential $800 + $75/app Final Approval Extension Residential $250 Non-Residential $350 * Subdivisions and Site Plans are subject to Engineering Review- See DPW Fees Demolition $500 Residential Structures – 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $75 Façade Change - removal/addition of windows, doors, porch $150 Addition or new construction $300 Approval Extension 50% of Application Fee 3+/Multi-Family, Comm, Mixed-Use Principal or Accessory Structure Equipment Install or Materials Change - roof, windows, siding, paint color $150 Signs, awnings $150 Façade Change - removal/addition of windows, doors, porch $300 Addition or new construction $650 Approval Extension or Modification 50% of Application Fee Post Work Application Fee Application x2 Other Lot Line Adjustment/Subdivision Administrative Action $400 Letter of Credit – Modification Extension $400 Letter of Credit - Collection up to 1% of LoC Recreation Fee $2,000/lot or unit Land Disturbance Activity Permit $750 + $35/acre Watercourse/Wetland Permit $750 Watercourse/Wetland Permit Extension $350 SEQRA EIS Review (Draft & Final) TBD Sidewalk Fee Lieu See DPW Fees Tree Removal Avg. nursery cost in caliper of new species equivalent to diameter at breat height (DBH of tree(s) Removed diameter at breat height (DBH of tree(s) Removed EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 EXCELSIOR PARK AFFODABLE HOUSING BDA#:20082 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 74 75 76 78 79 80 81 82 83 84 85 18 29 63 64 65 66 67 68 69 70 71 72 73 EVEVEVEVEV EV PROPERTY LINE WHISTLER COURT EXISTING 5 STORY APARTMENT BUILDING 24 . 5 ' 9' ASPHALT PAVEMENT, TYP. (PARKING LOT) CONCRETE PAVEMENT, TYP. PEDESTRIAN DROP CURB ACCESSIBLE PARKING SPACES 24' 5' 22' TYP. 9' TY P . 22' 9' 24 ' 18 ' 18 ' 9' 8 L-6.0 CONCRETE PAVEMENT, TYP.8 L-6.0 1 L-2.0 7 L-6.0 1 L-6.1 ASPHALT PAVEMENT, TYP. (STANDARD ROAD) 7 L-6.0 RAMP, SEE ARCHITECTURAL PLANS 4' 34' R3' (TY P . ) R 5 ' T Y P . R10 ' T Y P . KEY PAVEMENT, BLEND SMOOTHLY9 L-6.0 5. 5 ' STOP SIGN3 L-6.1 PEDESTRIAN CROSSWALK 12 L-6.0 6" CONCRETE CURB, TYP.11 L-6.0 EXISTING TOWNHOUSES 4, 6, 8, & 10 WHISTLER COURT TRANSITION CURB BUILDING 1 4 STORIES PLUS PARKING LEVEL 2,450 S.F. NON-RESIDENTIAL SPACE 50 UNITS 290 EXCELSIOR AVENUE TRASH ROOM B U I L D I N G S E T B A C K 22' TYP. 9' TY P . 9' TRANSITION CURB, TYP. TRANSITION CURB, TYP. TRANSITION CURB, TYP. DETECTABLE WARNING STRIP, TYP. 50 ' KEY PAVEMENT, BLEND SMOOTHLY 9 L-6.0 6 L-6.0 6 L-6.0 13 L-6.0 6 L-6.0 6 L-6.0 CONCRETE PAVEMENT, TYP.8 L-6.0 KEY PAVEMENT, BLEND SMOOTHLY 9 L-6.0 FIRE TRUCK TURNING MOVEMENT ELEVATORS TO UPPER FLOORS EXISTING TOWNHOUSES 12, 14, 16, & 18 WHISTLER COURT COVERED VERANDA CONCRETE PAVEMENT, TYP.8 L-6.0 R 1 0 ' T Y P . R5' CONCRETE CURB, TYP. BLEND SMOOTHLY WITH EXISTING CURB 11 L-6.0 8'8' HANDICAP PARKING SIGNAGE HANDICAP PARKING SIGN STOP SIGN 3 L-6.1 BUILDING OVERHANG EXCELSIOR AVENUE PROPERTY LINE PR O P E R T Y L I N E P R O P E R T Y L I N E NYS ROU T E 5 0 CURB STOPS, TYP.6 L-6.2(2) DUAL AND ONE SINGLE ELECTRIC VEHICLE STATIONS PLAYGROUND SURFACE AND EDGING 4 L-6.1 (2) BICYCLE RACK 5 L-6.2 9', TYP. 5.0 0 ' TYP . R 5 ' 5' 5.50' 3.50' 3 L-6.1 STAIRS, SEE ARCHITECTURAL PLANS GATE AND FENCE 2 L-6.2 CONCRETE CURB, TYP. 11 L-6.0 6.00'40.00' 25 . 0 0 ' 5. 0 0 ' STOP SIGN 3 L-6.1 (2) BENCH, TYP.4 L-6.2 "WHISTLER COURT" STREET SIGN CONSTRUCTION EASEMENT DRAINAGE EASEMENT CONSTRUCTION EASEMENT CONSTRUCTION EASEMENT EV READY SPACE SINGLE VEHICLE EV STATION (5) EV READY SPACES DUMPSTER ENCLOSURE ON HEAVY DUTY CONCRETE PAD RAMP, SEE ARCHITECTURAL PLANS CONCRETE SIDEWALK DETECTABLE WARNING STRIP 1/4" REVEAL (MAX.) HEAVY BROOM FINISH (TYP.) 3' TRANSITION CURB 6' MIN. 3' TRANSITION CURB Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Beacon Communities, LLC 54 State Street, Suite 802 Albany, NY 12207 G: \ P r o j - 2 0 2 0 \ 2 0 2 0 0 4 7 _ E x c e l s i o r _ P a r k _ A p a r t m e n t s - B e a c o n \ 2 0 2 0 0 4 7 C A D \ L - 2 . 0 _ L a y o u t P l a n . d w g Excelsior Apartments Excelsior Avenue Saratoga Springs, NY 12866 Project 7itle: Prepared for: Drawing 7itle Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020047 Site Layout & Materials Plan L-2.0 DRC KAC DRC 6/15/2026 1"=20' LEGEND 1.ALL LINE AND GRADE INFORMATION SHALL BE LAID OUT BY A NEW YORK STATE REGISTERED SURVEYOR ENGAGED BY THE CONTRACTOR. 2.ALL NEW WORK SHALL BE STAKED OUT PRIOR TO CONSTRUCTION. THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED OF ANY DISCREPANCIES. FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 3.ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES FROM WHICH THEY ARE MEASURED UNLESS OTHERWISE NOTED. 4.DIMENSIONS TO CURBS ARE FROM FACE OR BOTTOM OF CURB TO FACE OR BOTTOM OF CURB. 5.FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE AND IF NECESSARY APPROPRIATE MUNICIPAL OFFICIALS. 6.ALL LAYOUTS FOR WALKS AND PATHS SHALL BE ADEQUATELY STAKED BY THE CONTRACTOR AND APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 7.ALL PROPOSED WALKS, PAVEMENTS, LIGHTS AND SITE IMPROVEMENTS SHALL BE STAKED IN THE FIELD FOR APPROVAL BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 8.CONTRACTOR SHALL COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (WALLS, FENCE, FOOTINGS, TREE ROOTBALLS, PROPOSED LIGHTING FOOTINGS, ETC.). CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. 9.ALL EXISTING UTILITIES ARE SHOWN IN THEIR RELATIVE POSITION. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE VERTICAL & HORIZONTAL POSITION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION. LAYOUT NOTES: BUILDING SETBACK CONCRETE PAVEMENT PARKING LOT ASPHALT PAVEMENT STEEL FENCE PROPERTY LINE SIGNAGE (CONTROL JOINT)(EXPANSION JOINT) 6" CONCRETE CURB STONE DUST WALL TRANSITION CURB Scale: NTS PEDESTRIAN DROP CURB1 10 5 10 15 20200 Scale: 1" = 20' Planning Board # 20200735 & 20200736 ROADWAY ASPHALT PAVEMENT PLAYGROUND SURFACE CONSTRUCTION EASEMENT DRAINAGE EASEMENT NEW NEW 50 ' - 0 " 292'-7" 20 ' - 0 " 30 ' - 0 " 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 74 75 76 78 79 80 81 82 83 84 85 18 29 63 64 65 66 67 68 69 70 71 72 73 PROPERTY LINE WHISTLER COURT EXISTING 5 STORY APARTMENT BUILDING 22 ' 9' ASPHALT PAVEMENT, TYP. (PARKING LOT) CONCRETE PAVEMENT, TYP. PEDESTRIAN DROP CURB ACCESSIBLE PARKING SPACES 24' 5'5' 22' TYP. 9' TY P . 22' 9' 24 ' 18 ' 24 ' 18 ' 9' 8 L-6.0 CONCRETE PAVEMENT, TYP.8 L-6.0 1 L-2.0 7 L-6.0 1 L-6.1 ASPHALT PAVEMENT, TYP. (STANDARD ROAD) 7 L-6.0 ACCESSIBLE RAMP 4' 34' R5' T Y P . R4.5' R 5 ' T Y P . R10 ' T Y P . KEY PAVEMENT, BLEND SMOOTHLY9 L-6.0 5. 5 ' STOP SIGN3 L-6.1 PEDESTRIAN CROSSWALK 12 L-6.0 6" CONCRETE CURB, TYP.11 L-6.0 EXISTING TOWNHOUSES 4, 6, 8, & 10 WHISTLER COURT TRANSITION CURB 5 L-6.1BUILDING 1 4 STORIES PLUS PARKING LEVEL 2,450 S.F. NON-RESIDENTIAL SPACE 52 UNITS 290 EXCELSIOR AVENUE TRASH ROOM B U I L D I N G S E T B A C K 22' TYP. 9' TY P . 9' TRANSITION CURB, TYP. TRANSITION CURB, TYP. TRANSITION CURB, TYP. DETECTABLE WARNING STRIP, TYP. 50 ' KEY PAVEMENT, BLEND SMOOTHLY 9 L-6.0 6 L-6.0 6 L-6.0 13 L-6.0 6 L-6.0 6 L-6.0 CONCRETE PAVEMENT, TYP.8 L-6.0 KEY PAVEMENT, BLEND SMOOTHLY 9 L-6.0 FIRE TRUCK TURNING MOVEMENT ELEVATORS TO UPPER FLOORS 5' EXISTING TOWNHOUSES 12, 14, 16, & 18 WHISTLER COURT COVERED VERANDA CONCRETE PAVEMENT, TYP.8 L-6.0 R 1 0 ' T Y P . R5' CONCRETE CURB, TYP. BLEND SMOOTHLY WITH EXISTING CURB 11 L-6.0 8'8' HANDICAP PARKING SIGNAGE HANDICAP PARKING SIGN STOP SIGN 3 L-6.1 BUILDING OVERHANG EXCELSIOR AVENUE PROPERTY LINE PR O P E R T Y L I N E P R O P E R T Y L I N E NYS ROU T E 5 0 CURB STOPS, TYP.6 L-6.2 (4) ELECTRIC VEHICLE STATIONS PLAYGROUND SURFACE AND EDGING 4 L-6.1 (2) BICYCLE RACK 5 L-6.2 9', TYP. 5.0 0 ' TYP . R4.5'R4.5'R4.5' 5' 5.50' 3.50' 3 L-6.1 STAIRS, TYP.6 L-6.1 GATE AND FENCE 2 L-6.2 CONCRETE CURB, TYP. 11 L-6.0 6.00'40.00' 25 . 0 0 ' 5. 0 0 ' STOP SIGN 3 L-6.1 (2) BENCH, TYP.4 L-6.2 "WHISTLER COURT" STREET SIGN ACCESSIBLE RAMP 5 L-6.1 CONSTRUCTION EASEMENT DRAINAGE EASEMENT CONSTRUCTION EASEMENT CONSTRUCTION EASEMENT CONCRETE SIDEWALK DETECTABLE WARNING STRIP 1/4" REVEAL (MAX.) HEAVY BROOM FINISH (TYP.) 3' TRANSITION CURB 6' MIN. 3' TRANSITION CURB Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Beacon Communities, LLC 54 State Street, Suite 802 Albany, NY 12207 G: \ P r o j - 2 0 2 0 \ 2 0 2 0 0 4 7 _ E x c e l s i o r _ P a r k _ A p a r t m e n t s - B e a c o n \ 2 0 2 0 0 4 7 C A D \ L - 2 . 0 _ L a y o u t P l a n . d w g Excelsior Apartments Excelsior Avenue Saratoga Springs, NY 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2020047 Site Layout & Materials Plan L-2.0 DRC KAC DRC 10/14/2020 1"=20' 1 Revised Per City Comment4/14/2021 2 Revised Per City Comment5/4/2021 3 Townhouse Removal 1/21/2022 4 Revised Per City Comment4/13/2022 5 Updated Unit Number 5/25/2022 LEGEND 1.ALL LINE AND GRADE INFORMATION SHALL BE LAID OUT BY A NEW YORK STATE REGISTERED SURVEYOR ENGAGED BY THE CONTRACTOR. 2.ALL NEW WORK SHALL BE STAKED OUT PRIOR TO CONSTRUCTION. THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED OF ANY DISCREPANCIES. FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 3.ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES FROM WHICH THEY ARE MEASURED UNLESS OTHERWISE NOTED. 4.DIMENSIONS TO CURBS ARE FROM FACE OR BOTTOM OF CURB TO FACE OR BOTTOM OF CURB. 5.FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE AND IF NECESSARY APPROPRIATE MUNICIPAL OFFICIALS. 6.ALL LAYOUTS FOR WALKS AND PATHS SHALL BE ADEQUATELY STAKED BY THE CONTRACTOR AND APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 7.ALL PROPOSED WALKS, PAVEMENTS, LIGHTS AND SITE IMPROVEMENTS SHALL BE STAKED IN THE FIELD FOR APPROVAL BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 8.CONTRACTOR SHALL COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (WALLS, FENCE, FOOTINGS, TREE ROOTBALLS, PROPOSED LIGHTING FOOTINGS, ETC.). CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. 9.ALL EXISTING UTILITIES ARE SHOWN IN THEIR RELATIVE POSITION. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE VERTICAL & HORIZONTAL POSITION OF EXISTING UTILITIES PRIOR TO CONSTRUCTION. LAYOUT NOTES: BUILDING SETBACK CONCRETE PAVEMENT PARKING LOT ASPHALT PAVEMENT STEEL FENCE PROPERTY LINE SIGNAGE (CONTROL JOINT)(EXPANSION JOINT) 6" CONCRETE CURB STONE DUST WALL TRANSITION CURB Scale: NTS PEDESTRIAN DROP CURB1 10 5 10 15 20200 Scale: 1" = 20' Planning Board # 20200735 & 20200736 ROADWAY ASPHALT PAVEMENT PLAYGROUND SURFACE CONSTRUCTION EASEMENT DRAINAGE EASEMENT PREVIOUS SUBMISSION UP UP DN DN DWDW DN UP DW DW Z-003 D ELEC RM 002 TRASH STORAGE 006 A-2021 A-200 1 A-201 1 A-202 2 3 A-301 50 ' - 0 " 295'-1 3/4" BIKE STORAGE 003 VEST. 007 1 A-301 2 / A -10 0 1 / A -10 0 A-354 2 A-351 1 UNEXCAVATED UNEXCAVATED UNEXCAVATED 2 A-301 A-355 1 MECH ROOM 001 1 2 5 6 7 8 9 10 12 19 A B F RE C Y C L I N G AR E A 14 16 D ELEV. MACHINE RM 009 ELEV. STAIR 2 004 4 A-310 2 A-311 Z-003 ENTRY LOBBY 101 CORRIDOR 103 TRASH 105 JANITOR CLOSET 105A VEST. 100 A-2021 A-201 1 A-202 2 3 A-301 2 BEDROOM UNIT 109 2 BEDROOM UNIT 108 2 BEDROOM UNIT 107 1 BEDROOM UNIT 106 1 BEDROOM UNIT 104 3 B E D R O O M UN I T 1 0 3 1 BEDROOM UNIT 102 1 BEDROOM UNIT 101 1 BEDROOM UNIT 100 3 B E D R O O M UN I T 1 1 0 PARCELS 108 STOR. 110A COMMUNITY ROOM 112 CORRIDOR 109 RR 112A RR 114A LAUNDRY 113 COPY 114 OFFICE 116 REC. 118 CONF. 115 FITNESS 102 STAIR 1 111 STAIR 2 104 A-402 1 TYP. 1 A-301 1 BEDROOM UNIT 105 2 / A -10 2 1 / A -10 2 A-350 1 A-354 5 A-351 2 SPACE LEGEND 1 BEDROOM 2 BEDROOM 3 BEDROOM TYPE 1 3 BEDROOM TYPE 2 COMMON SPACE STAIR, ELEV, MECHANICALS ELEV. LOBBY 106 A-352 3 A-352 1 A-352 4 2 A-301 A-355 2 OFFICE 117 1 3 4 6 8 9 9.6 11 13 15 17 18 19 A B C F D E ELEV. 4 A-310 IT 110 2 A-311 Z-003 CORRIDOR 204 JANITOR CLOSET 202A TRASH 202 A-2021 A-200 1 A-201 1 A-202 2 3 A-301 3 B E D R O O M UN I T 2 1 0 3 BEDROOM UNIT 209 2 BEDROOM UNIT 211 2 BEDROOM UNIT 212 2 BEDROOM UNIT 200 2 BEDROOM UNIT 201 2 BEDROOM UNIT 202 1 BEDROOM UNIT 203 1 BEDROOM UNIT 208 2 BEDROOM UNIT 207 2 BEDROOM UNIT 206 3 BEDROOM UNIT 205 3 B E D R O O M UN I T 2 0 4 STAIR 1 206 STOR. 205 A-404 1 TYP. A-408 1 TYP. 1 A-301 1 / A -10 2 2 / A -10 2 A-354 6 A-350 2 A-351 3 2 A-301 ELEV. 203 STAIR 2 201 1 3 4 6 8 9 9.6 11 13 15 17 18 19 A B C F A-402 1 TYP. E B.5 UNCONDITIONED VERANDA 4 A-310 2 A-311 UNIT SUMMARY: 50 TOTAL UNITS • 20% MI UNITS (10) • (2) 1 BED • (5) 2 BED • (3) 3 BED • 6% HVI UNITS (3) • (1) 1 BED • (1) 2 BED • (1) 3 BED 40 TYPE B UNITS SYMBOL: NOT FOR CONSTRUCTION no. revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 1 1 / 2 0 2 6 1 1 : 4 2 : 5 0 A M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 OVERALL BUILDING PLANS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-004 75% CONSTRUCTION DOCUMENTS SCALE: 1/16" = 1'-0" 1 PARKING LEVEL SCALE: 1/16" = 1'-0" 3 SECOND FLOOR PLAN SCALE: 1/16" = 1'-0" 2 FIRST FLOOR PLAN UNIT MIX UNIT TYPE QUANTITY 1 BEDROOM 12 2 BEDROOM 24 3 BEDROOM 14 50 PLAN NORTH 16'8'0'32'48' SCALE : 1/16" = 1'-0" 1 Revision 1 11.17.2015 DN UP DW DW DN UP DW DW JANITOR CLOSET 302A TRASH 302 A-2021 A-201 1 3 A-301 1 A-301 1 / A -10 3 2 / A -10 3 2 A-301 3 B E D R O O M UN I T 3 1 0 3 BEDROOM UNIT 309 2 BEDROOM UNIT 311 2 BEDROOM UNIT 312 2 BEDROOM UNIT 300 2 BEDROOM UNIT 301 2 BEDROOM UNIT 302 1 BEDROOM UNIT 303 1 BEDROOM UNIT 308 2 BEDROOM UNIT 307 2 BEDROOM UNIT 306 3 BEDROOM UNIT 305 3 B E D R O O M UN I T 3 0 4 A-351 3A-350 2 A-354 6 STAIR 2 301STAIR 1 306 STOR. 305 CORRIDOR 300 CORRIDOR 304 1 3 4 6 8 9.6 11 13 15 17 18 19 A B C F E ELEV. 4 A-310 2 A-311 CORRIDOR 400 A-2021 A-201 1 TRASH 402 JANITOR CLOSET 402A 3 A-301 SPACE LEGEND 1 BEDROOM 2 BEDROOM 3 BEDROOM TYPE 1 3 BEDROOM TYPE 2 COMMON SPACE STAIR, ELEV, MECHANICALSSTAIR 1 406 STOR. 405 1 A-301 1 / A -10 4 2 / A -10 4 A-350 5 A-351 7 2 A-301 3 B E D R O O M UN I T 4 1 0 3 BEDROOM UNIT 409 2 BEDROOM UNIT UNIT 411 2 BEDROOM UNIT UNIT 412 2 BEDROOM UNIT 400 2 BEDROOM UNIT 401 2 BEDROOM UNIT 402 1 BEDROOM UNIT 403 1 BEDROOM UNIT 408 2 BEDROOM UNIT 407 2 BEDROOM UNIT 406 3 BEDROOM UNIT 405 3 B E D R O O M UN I T 4 0 4 STAIR 2 401 CORRIDOR 404 1 3 4 6 8 9.6 11 13 15 17 18 19 A B C F E 4 A-310 2 A-311 3 A-301 1 A-301 1 / A -10 5 2 / A -10 5 2 A-301 1 3 4 6 8 9.6 11 13 15 17 18 19 A B C F D E B.5 4 A-310 2 A-311 UNIT SUMMARY: 50 TOTAL UNITS • 20% MI UNITS (10) • (2) 1 BED • (5) 2 BED • (3) 3 BED • 6% HVI UNITS (3) • (1) 1 BED • (1) 2 BED • (1) 3 BED 40 TYPE B UNITS ALL UNITS SHALL MEET THE CRITERIA FOR VISITABLE UNITS (TYPE C) SYMBOL: NOT FOR CONSTRUCTION no. revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 1 1 / 2 0 2 6 1 1 : 4 2 : 5 6 A M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 OVERALL BUILDING PLANS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-005 75% CONSTRUCTION DOCUMENTS SCALE: 1/16" = 1'-0" 1 THIRD FLOOR PLAN SCALE: 1/16" = 1'-0" 2 FOURTH FLOOR PLAN SCALE: 1/16" = 1'-0" 3 ROOF PLAN 16'8'0'32'48' SCALE : 1/16" = 1'-0" PLAN NORTH UNIT MIX UNIT TYPE QUANTITY 1 BEDROOM 12 2 BEDROOM 24 3 BEDROOM 14 50 290'-4" 50 ' - 0 " 30 ' - 0 " 20 ' - 0 " STAIR ELECTRICAL ROOM MECHANICAL ROOM GAS METERING ELEVATOR STAIR TRASH ROOM TRASH STORAGE AREA FOR WALL MOUNTED ELECTRIC METERS AND CONDENSER UNITS Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 3 / 2 0 2 1 1 0 : 5 9 : 3 2 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-100 07.07.2021 BUILDING KEY PLANS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" 1 PARKING LEVEL PLAN NORTH 16'8'0'32'48' SCALE : 1/16" = 1'-0" PREVIOUS SUBMISSION DN DW DW ROOM LEGEND 1 BEDROOM 2 BEDROOM 3 BEDROOM COMMON SPACE STAIR, ELEL, MECHANICALS STAIR, ELEV, MECHANICALS Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 4 : 5 5 : 2 9 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-101 07.07.2021 BUILDING KEY PLANS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 - JLB/JBC 2021 PLAN NORTH UNIT MIX UNIT TYPE QUANTITY 1 BEDROOM 18 2 BEDROOM 21 3 BEDROOM 9 TOWNHOUSES 10 58 SCALE: 1/16" = 1'-0" 3 THIRD FLOOR PLAN SCALE: 1/16" = 1'-0" 4 FOURTH FLOOR PLAN SCALE: 1/16" = 1'-0" 1 FIRST FLOOR PLAN SCALE: 1/16" = 1'-0" 2 SECOND FLOOR PLAN PREVIOUS SUBMISSION GROUND FLOOR 0" SECOND FLOOR 13'-1" THIRD FLOOR 22'-8" FOURTH FLOOR 32'-3" T/ PARAPET 46'-8" 52 ' - 9 " ± FINISH GRADE 1 A-301 13 ' - 1 " 9' - 7 " 9' - 7 " 8' - 2 " 6' - 3 " AVG GRADE PLANE 2 A-301 123455.566.77899.610111213151718191416 T/ PLATE 40'-5" 5' - 0 5 / 8 " FC-1 FC-2 FC-4 BRICK CONCRETE GLULAM COLUMN/BRACES EXTERIOR RAILING SYSTEM BUILDING IDENTIFICATION SIGNAGE LOUVER SHADING SYSTEM EXTERIOR DOWN LIGHTING 410 409 309310 210 209 111 110 108 208 308 408 407 307 207 107 109 101 403 402 303 302 203 202 201 RG 301 401 400 300 200RG 449 448 349 348 248249 447 347 228 139140141100101 102103 443 440 340341 241 240 130131 102 242 342 442 132 07 42 43 2 A-301 1234899.610111215171819 GUARDRAIL SYSTEM 16 TIE ROD CANOPY NOT FOR CONSTRUCTION no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 2 5 / 2 0 2 6 5 : 0 4 : 5 3 P M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 BUILDING ELEVATIONS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-200 75% CONSTRUCTION DOCUMENTS SCALE:1/16" = 1'-0"1 NORTH ELEVATION SCALE:1/8" = 1'-0"2 NORTH ELEVATION ENLARGED AREAS 16'8'0'32'48' SCALE : 1/16" = 1'-0" 0'8'4'16'24' SCALE : 1/8" = 1'-0" BRICK EXTERIOR RAILING SYSTEM EXTERIOR DOWN LIGHTING BUILDING IDENTIFICATION SIGNAGE CONCRETE LOUVER SHADING SYSTEM GLULAM COLUMNS/BRACES STEEL CONNECTION 123456789101112131415161718192021232425262728293022 52 ' - 9 " ± 24252627282930 01 04 08 121314151617181920 16 07 09 15 10 05 11 1718 09 1234 06 02 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 4 : 5 5 : 4 8 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-201 07.07.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" A NORTH ELEVATION PREVIOUS SUBMISSION GROUND FLOOR 0" SECOND FLOOR 13'-1" THIRD FLOOR 22'-8" FOURTH FLOOR 32'-3" T/ PARAPET 46'-8" PARKING LEVEL -12'-0" 1 A-301 2 A-301 1 2 3 4 5 5.5 6 6.7 7 8 9 9.6 10 11 12 13 15 17 18 191416 OPEN OPEN OPEN OPENOPEN OPEN OPEN OPEN 4 A-310 T/ STAIR TOWER 51'-8 3/8" 63 ' - 8 1 / 2 " 6' - 3 " 8' - 2 " 9' - 7 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " T/ PLATE 40'-5" 5' - 0 1 / 2 " 1 A-301 FC-1 FC-2 FIBER CEMENT PANEL 3 BRICK CL-FENCE 435 335 235 434 334 234 233 333 433 432 332 232 124 125 123 122 121 120 230231 331 330 430431 419 319 219 119 218 318 418 417 317 217 118 416 316 216 117 116 215 315 415 1 2 3 4 5 5.5 6 15 17 18 1916 009 OPEN OPEN OPEN 4 A-310 FC-1 010004 OPEN NOT FOR CONSTRUCTION no. revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 2 5 / 2 0 2 6 5 : 0 4 : 5 8 P M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 BUILDING ELEVATIONS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-201 75% CONSTRUCTION DOCUMENTS SCALE: 1/16" = 1'-0" 1 SOUTH ELEVATION SCALE: 1/8" = 1'-0" 2 SOUTH ELEVATION ENLARGED AREAS 16'8'0'32'48' SCALE : 1/16" = 1'-0" 0'8'4'16'24' SCALE : 1/8" = 1'-0" BRICK FC-1 FC-4 FC-4 CL-FENCE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 3022 1 2 3 4 5 6 7 8 9 06 01 07 0311 24 25 26 27 28 29 30 08 04 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 4 : 5 6 : 0 5 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-202 07.07.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" A SOUTH ELEVATION PREVIOUS SUBMISSION GROUND FLOOR 0" GROUND FLOOR 0" SECOND FLOOR 13'-1" SECOND FLOOR 13'-1" THIRD FLOOR 22'-8" THIRD FLOOR 22'-8" FOURTH FLOOR 32'-3" FOURTH FLOOR 32'-3" T/ PARAPET 46'-8" T/ PARAPET 46'-8" PARKING LEVEL -12'-0" 3 A-301 414 314 214 115 FINISH GRADE 8' - 2 " 9' - 7 " 9' - 7 " 13 ' - 1 " 51 ' - 8 1 / 2 " EXCELSIOR AVENUE FC-4 FC-1 FC-3 FC-2 BRICK GLULAM COLUMNS/BRACES EXTERIOR RAILING SYSTEM 112114113 211213212 311313312 412 411413 AVG GRADE PLANE ABCFDEB.5 T/ STAIR TOWER 51'-8 3/8" T/ STAIR TOWER 51'-8 3/8" 2 A-311 FC-1 TIE ROD CANOPY 5' - 0 1 / 2 " 63 ' - 8 1 / 2 " 6' - 3 " 8' - 2 " 9' - 7 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " CL FENCE T/ PLATE 40'-5" T/ PLATE 40'-5" 6' - 3 " 5' - 0 3 / 8 " GROUND FLOOR 0" GROUND FLOOR 0" SECOND FLOOR 13'-1" SECOND FLOOR 13'-1" THIRD FLOOR 22'-8" THIRD FLOOR 22'-8" FOURTH FLOOR 32'-3" FOURTH FLOOR 32'-3" T/ PARAPET 46'-8" T/ PARAPET 46'-8" PARKING LEVEL -12'-0" PARKING LEVEL -12'-0" STAIR TO ROOF BEYOND 3 A-301 63 ' - 8 1 / 2 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " 8' - 2 " 9' - 7 " FINISH GRADE EXCELSIOR AVENUE FC-1 FC-3 FC-3 BRICK EXTERIOR RAILING SYSTEM GLULAM COLUMNS/BRACES 439 339 239 238 338 438 437 337 237 436 336 236 126 127128129 AVG GRADE PLANE A B C FDEB.5 T/ STAIR TOWER 51'-8 3/8" T/ STAIR TOWER 51'-8 3/8" 2 A-311 5' - 0 1 / 2 " 63 ' - 8 1 / 2 " 6' - 3 " 8' - 2 " 9' - 7 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " T/ PLATE 40'-5" T/ PLATE 40'-5" 6' - 3 " 5' - 0 3 / 8 " NOT FOR CONSTRUCTION no. revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 2 5 / 2 0 2 6 5 : 0 5 : 0 2 P M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 BUILDING ELEVATIONS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-202 75% CONSTRUCTION DOCUMENTS SCALE: 1/8" = 1'-0" 1 EAST ELEVATION SCALE: 1/8" = 1'-0" 2 WEST ELEVATION 0'8'4'16'24' SCALE : 1/8" = 1'-0" 0'8'4'16'24' SCALE : 1/8" = 1'-0" BRICK FC-1 FC-2 FC-3 EXTERIOR RAILING SYSTEM FC-4 FC-1 GLULAM COLUMNS/BRACES BRICK EXTERIOR RAILING SYSTEM STEEL CONNECTION STEEL CONNECTION CHARCOAL BLUE CHARCOAL BLUE TAG DESCRIPTION TYPE NOTE FC 1 NOVENARY BY NICHIHA, COLOR "OPAL" FIBER CEMENT SIDING SYSTEM FC 2 VINTAGEWOOD BY NICHIHA, COLOR "BARK" FIBER CEMENT SIDING SYSTEM FC 3 ILLUMINATION BY NICHIHA, COLOR "CUSTOM" FIBER CEMENT SIDING SYSTEM CHARCOAL BLUE BY SHERWIN WILLIAMS SW2739 FC 4 RIBBED BY NICHIHA, COLOR "INDIGO" FIBER CEMENT SIDING SYSTEM BRICK URBAN GREY BY GLEN-GERY OR EQUAL MODULAR FACEBRICK FENESTRATION WINDOWS 100 SERIES BY ANDERSEN, COLOR "BLACK" FIBREX WINDOWS UPDATED SELECTION CONCRETE SITE CAST REINFORCED CONCRETE CONCRETE FINAL SPECIFICATON TO BE DETERMINED STEEL CONNECTION CUSTOM FABRICATED STEEL CONNECTIONS, PAINT FINISH STEEL ELEMENT CONNECTIONS FINAL SPECIFICATON TO BE DETERMINED GLULAM STRESS RATED ENGINEERED WOOD BEAMS/COLUMNS GLULAM FINAL SIZING/SPECIFICATION TO BE DETERMINED EXTERIOR RAILING SYSTEM STAINLESS STEEL WIRE MESH GUARDRAIL EXTERIOR RAILING SYSTEM UPDATED SELECTION CL-FENCE CHAIN LINK FENCE EXTERIOR FENCE SYSTEM LOUVER SHADING SYSTEM MILL FINISH ALUMINUM EXTERIOR LOUVER SYSTEM EXTERIOR SIGNAGE BACKLIT METALLIC POWDERCOATED BUILDING SIGNAGE BUILDING IDENTIFICATION FINAL SIGNAGE SCHEME TO BE DETERMINED UNDER SEPARATE APPROVAL EXTERIOR DOWNLIGHTING LDN6 CYLINDER SERIES BY LITHONIA LIGHTING, BLACK EXTERIOR DOWNLIGHTING EXTERIOR DOWNLIGHTING ARC LED WALL MOUNT LUMINAIRES BY LITHONIA LIGHTING, BLACK EXTERIOR WALL-MOUNTED LIGHTING SIDING VISIBLE STRUCTURAL ACCESSORIES AND LIGHTING DESIGN REVIEW MATERIALS AND FINISHES GROUND FLOOR 306'-11" SECOND FLOOR 320'-0" THIRD FLOOR 329'-7" FOURTH FLOOR 339'-2" PARAPET 352'-10 5/8" ABCE PARKING LEVEL 294'-11" D GROUND FLOOR 306'-11" SECOND FLOOR 320'-0" THIRD FLOOR 329'-7" FOURTH FLOOR 339'-2" PARAPET 352'-10 5/8" A B C E PARKING LEVEL 294'-11" D STAIR TO ROOF BEYOND 04 03 07 01 06 15 08 09 19 11 11 20 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 4 : 5 7 : 5 5 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-203 07.07.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE:1/8" = 1'-0"A EAST ELEVATION EXCELSIOR AVENUE EXCELSIOR AVENUE DESIGN REVIEW MATERIALS AND FINISHES TAG DESCRIPTION TYPE NOTE SIDING 01 NOVENARY BY NICHIHA, COLOR "OPAL" FIBER CEMENT SIDING SYSTEM 02 VINTAGEWOOD BY NICHIHA, COLOR "BARK" FIBER CEMENT SIDING SYSTEM 03 ILLUMINATION BY NICHIHA, COLOR "CUSTOM" FIBER CEMENT SIDING SYSTEM 04 RIBBED BY NICHIHA, COLOR "INDIGO" FIBER CEMENT SIDING SYSTEM 05 OUTSULATION RMD SYSTEM BY DRYVIT OR EQUAL, "SANDBLAST" FINISH EXTERIOR INSULATION FINISH SYSTEM 06 URBAN GREY BY GLEN-GERY OF EQUAL MODULAR FACEBRICK FENESTRATION 07 IMPERVIA BY PELLA, COLOR "BLACK" DURACAST FIBERGLASS COMPOSITE WINDOWS VISIBLE STRUCTURAL 08 SITE CAST REINFORCED CONCRETE CONCRETE FINAL SPECIFICATION TO BE DETERMINED 09 CUSTOM FABRICATED STEEL CONNECTIONS, PAINT FINISH STEEL ELEMENT CONNECTIONS FINAL SPECIFICATION TO BE DETERMINED 10 STRESS RATED ENGINEERED WOOD BEAMS/COLUMNS GLULAM FINAL SIZING/SPECIFICATIONS TO BE DETERMINED COLORS 11 CHARCOAL BLUE BY SHERWIN WILLIAMS SW2739 COLOR FINISH 12 GREEN-EARTH BY SHERWIN WILLIAMS SW7748 COLOR FINISH 13 SUMMIT-GREY BY SHERWIN WILLIAMS SW7669 COLOR FINISH 14 SNOWBOUND BY SHERWIN WILLIAMS SW7004 COLOR FINISH ACCESSORIES AND LIGHTING 15 STAINLESS STEEL MODULAR MESH "CIRA" BY VIVA RAILINGS OR EQUAL EXTERIOR RAILING SYSTEM SATIN FINISH 16 MILL FINISH ALUMINUM EXTERIOR LOUVER SYSTEM 17 BACKLIT METALLIC POWDERCOATED BUILDING SIGNAGE BUILDING IDENTIFICATION FINAL SIGNAGE SCHEME TO BE DETERMINED UNDER SEPARATE APPROVAL 18 LDN6 CYLINDER SERIES BY LITHONIA LIGHTING, BLACK EXTERIOR DOWNLIGHTING 19 ARC LED WALL MOUNTED LUMINAIRES BY LITHONIA LIGHTING, BLACK EXTERIOR WALL-MOUNTED LIGHTING 20 CHAIN LINK FENCING PREVIOUS SUBMISSION Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 4 : 4 9 : 4 7 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - T o w n h o s e - V 2 0 2 1 _ s f o l t s 2 N W E Q .r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C ZA-201 7.7.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 HCR Submission - 20082 - - 2018 0'8'4'16'24' SCALE : 1/8" = 1'-0" SCALE: 3/32" = 1'-0" 1 SOUTH ELEVATION SCALE: 3/16" = 1'-0" 2 SOUTH ELEVATION SCALE: 3/16" = 1'-0" 3 WEST ELEVATION PREVIOUS SUBMISSION NO LONGER PROPOSED REF. UP DW DN W/D DN 24 ' - 0 " 1' - 6 " UP 30 SF BULK 10 SF COATS 21 SF MECH30 SF 1/2 BATH 101 SF KITCHEN 354 SF DINING/LIVING PANTRY A P VENT TO EXTERIOR 12'-6"12'-6" 25'-0" 3' - 0 " 24 ' - 0 " 3' - 0 " 9 SF CLOS 162 SF MASTER BEDROOM #1 106 SF BEDROOM #2 3' - 3 1 / 4 " 3'-3 3/8" 14 SF CLOS 18 SF STOR 50 SF BATH 114 SF BEDROOM #3 10 SF CLOS 11'-5 3/4" 10 ' - 1 1 / 8 " 109 SF HALL VENT TO EXTERIOR 3 SF L 8'-7 7/8" 12'-6"12'-6" 25'-0" 17'-6" 2 5 2 07 11 12 1304 05 14 18 08 17 06 FIRST FLOOR 0" SECOND FLOOR 9'-5 7/8" T/WALL 17'-7" T/ROOF FRAMING 18'-11" Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 4 : 3 7 : 5 9 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - T o w n h o s e - V 2 0 2 1 _ s f o l t s 2 N W E Q .r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-102 7.7.2021 TOWNHOUSE PLANS AND ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 HCR Submission TMS/JBC 20082 - JLB/TMS 2018 PLAN NORTH 0'4'2'8'12' SCALE : 1/4" = 1'-0"SCALE:1/4" = 1'-0"A FIRST FLOOR PLAN SCALE: 1/4" = 1'-0" B SECOND FLOOR PLAN SCALE: 1/4" = 1'-0" 1 NORTH ELEVATION SCALE: 1/4" = 1'-0" 2 SOUTH ELEVATION PREVIOUS SUBMISSION NO LONGER PROPOSED NOT FOR CONSTRUCTION no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 2 5 / 2 0 2 6 5 : 1 3 : 2 8 P M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 WIRE MESH GUARDRAIL BOD EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-203 75% CONSTRUCTION DOCUMENTS NEW NOT FOR CONSTRUCTION no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ n g s \ D o c u m e n t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6 _ N o D a y c a r e _n s e a g r i f f W F W E 9 . r v t 6 / 2 5 / 2 0 2 6 9 : 3 6 : 3 9 P M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 WINDOW SAMPLE EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-503 75% CONSTRUCTION DOCUMENTS NEW THAT ’S EASY ON THE BUDGET. A MODERN LOOK 100 SERIES 2022 PRODUCT GUIDE FOR PROFESSIONALS CONTENTS Performance .......................................................................................... 2 Durability ............................................................................................... 3 Fibrex® Material ............................................................................. 4-5 Window & Door Types ................................................................. 6-7 New Construction, Remodeling & Replacement ........................ 9 Exterior & Interior Colors ................................................................ 10 Hardware ........................................................................................... 11 Glass Options ................................................................................... 12 Grille & Insect Screen Options ..................................................... 13 Build Bigger Views ........................................................................... 14 100 SERIES WINDOWS Windows Overview ........................................................................ 15 Casement Windows ................................................................... 18 Awning Windows ........................................................................ 25 Single-Hung Windows .............................................................. 30 Gliding Windows ........................................................................ 52 Picture, Transom & Specialty Windows ................................ 66 100 SERIES PATIO DOORS Patio Doors Overview ..................................................................... 91 Gliding Patio Doors .................................................................... 93 Patio Door Sidelights & Transoms ........................................... 95 Combination Designs ...................................................................... 99 Product Performance .....................................................................102 Installation Accessories & Information ..................................... 109 Sustainability .................................................................................... 112 For warranty information, visit andersenwindows.com/warranty. Lorem ipsum Andersen Corporation, including its subsidiaries, has been named a 2021 ENERGY STAR Partner of the Year – Sustained Excellence Award winner, the highest honor given by ENERGY STAR, for continued leadership in protecting the environment through superior energy efficiency achievements.“ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. CONTENTS Performance .......................................................................................... 2 Durability ............................................................................................... 3 Fibrex® Material ............................................................................. 4-5 Window & Door Types ................................................................. 6-7 New Construction, Remodeling & Replacement ........................ 9 Exterior & Interior Colors ................................................................ 10 Hardware ........................................................................................... 11 Glass Options ................................................................................... 12 Grille & Insect Screen Options ..................................................... 13 Build Bigger Views ........................................................................... 14 100 SERIES WINDOWS Windows Overview ........................................................................ 15 Casement Windows ................................................................... 18 Awning Windows ........................................................................ 25 Single-Hung Windows .............................................................. 30 Gliding Windows ........................................................................ 52 Picture, Transom & Specialty Windows ................................ 66 100 SERIES PATIO DOORS Patio Doors Overview ..................................................................... 91 Gliding Patio Doors .................................................................... 93 Patio Door Sidelights & Transoms ........................................... 95 Combination Designs ...................................................................... 99 Product Performance .....................................................................102 Installation Accessories & Information ..................................... 109 Sustainability .................................................................................... 112 For warranty information, visit andersenwindows.com/warranty. Lorem ipsum Andersen Corporation, including its subsidiaries, has been named a 2021 ENERGY STAR Partner of the Year – Sustained Excellence Award winner, the highest honor given by ENERGY STAR, for continued leadership in protecting the environment through superior energy efficiency achievements.“ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. 1 *2020 Andersen brand surveys of U.S. realtors, contractors and builders. **2020 Andersen brand surveys of U.S. contractors, builders and architects. †See the limited warranty for details. AMERICA’S MOSTLOVED BRAND OF WINDOWS & DOORS.* 100 SERIES PRODUCTS You want to give your customers a home they love, and we’re here to make that easy for you. That’s why we’re proud to offer you products that rate #1 in quality and performance,** and to be the #1 trusted and recommended window and door brand** by pros. The best way to give your customers a modern look that’s within budget and lasts.† The 100 Series product line is made from our proprietary Fibrex® material that’s energy efficient, environmentally responsible and stronger than vinyl. 2 COLORS THAT LAST Durable factory-finished interiors and exteriors never need painting and won’t fade, flake, blister or peel,* even in extreme cold or heat. ENERGY EFFICIENT IN EVERY CLIMATE Energy-efficient 100 Series products are available with options that make them ENERGY STAR® certified throughout the U.S. so they can help reduce heating and cooling bills. Visit andersenwindows.com/energystar for more information and to verify that the product with your glass option is certified in your area. QUALITY SO SOLID, THE WARRANTY IS TRANSFERABLE* Many other window and door warranties end when a home is sold, but our coverage — 20 years on glass, 10 years on non-glass parts — transfers from each owner to the next. And because it's not prorated, the coverage offers full benefits year after year, owner after owner. So it can add real value when you decide to sell your home. DESIGNED FOR PERFORMANCE 100 Series products are designed to meet or exceed performance requirements in all 50 states.† See pages 103-104 for details. PERFORMANCE 100 Series products simply perform like modern windows and doors should. They’re made from our proprietary Fibrex® material, which is extremely low maintenance and blocks thermal transfer 700 times better than aluminum to help your customers save money on heating and cooling costs. *Visit andersenwindows.com/warranty for details. **Products with Sandtone, dark bronze and black interiors have matching exteriors. †See your local code official for code requirements in your area. ††100SHS4066 DPUP IG +50/50 (AAMA/WDMA/CSA 101/I.S.2/A440-08 & -11). Optional PG50 performance grade upgrade is available for most sizes. For more information, visit andersenwindows.com/100series. “ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. SUPERIOR WEATHER RESISTANCE Our weather-resistant construction seals out drafts, wind and water so well that your reputation is protected whatever the weather. ATTRACTIVE CORNER SEAMS Low-visibility corner seams for a cleaner and more modern look. ATTRACTIVE MATTE INTERIORS Premium matte finish isn’t shiny like vinyl and is available in white, Sandtone, dark bronze and black.** EASY TO OPERATE FOR YEARS TO COME All 100 Series products are tested to the extreme to deliver years* of smooth, reliable operation. PG 50 PERFORMANCE 100SHS4066 DPUP +50/-50 (AAMA/WDMA/CSA 101/I.S.2/A440-08 & -11) OPTIONAL PERFORMANCE UPGRADE †† 3 *See the limited warranty for details. **When 100 Series products were tested against five leading competitors’ painted vinyl window products. DURABILITY Think vinyl, only stronger. The proprietary Fibrex® material in our 100 Series products has all the benefits of vinyl while holding up better to weather and wear. This way, your customers’ windows and doors are better protected from warping and cracking, even in tough climates.* The finish on 100 Series products has superior scratch resistance compared to painted vinyl windows** so they’ll look beautiful for years to come. Fibrex material retains its stability and rigidity in all climates, delivering exceptional durability. It makes our 100 Series products rigid and strong so the weathertight seals stay weathertight. 100 Series products can withstand temperatures up to 150◦F, even for dark colors, meaning they won’t warp due to sun exposure. ** 150WITHSTANDS TEMPERATURES 4 *Visit andersenwindows.com/warranty for details. **When tested against five leading competitors’ painted vinyl window products. REVOLUTIONARY BUILDING MATERIAL • Twice as strong as vinyl so weathertight seals stay weathertight • Blocks thermal transfer nearly 700 times better than aluminum to help reduce heating and cooling bills • Retains its stability and rigidity in all climates for exceptional durability • Offers superior scratch resistance compared to painted vinyl* ENVIRONMENTALLY RESPONSIBLE • Since Andersen developed the highly sustainable Fibrex material, reuse of waste wood fiber has prevented the harvesting of nearly 90 million board feet of timber • 100 Series products can help builders earn LEED® points in three key categories: Energy & Atmosphere, Materials & Resources and Indoor Environmental Quality • 100 Series products meet or exceed California Section 01350 Specification, a California indoor emission standard — one of the toughest in the country • Like all Andersen products, 100 Series products are designed to last** and help reduce future waste streams See how Andersen created Fibrex material at andersenwindows.com/fibrex. FIBREX® MATERIAL Developed by Andersen, Fibrex material is a revolutionary structural composite material that blends the very best attributes of vinyl and wood. Fibrex material saves on natural resources because it’s composed of 40% reclaimed wood fiber by weight. Special polymer formulations surround and fill each wood fiber, enabling top performance. The result is a material that provides uncommon value and enhances the quality of any project. In use for over two decades in Andersen® products, Fibrex material has proven its strength and durability in all types of climates. 5 400,000 Av e r a g e M o d u l u s Fibrex® Material Vinyl Pine 385,800 STABLE & PREDICTABLE Fibrex ® material is twice as stiff as vinyl. This strength makes it a better choice over time. DURABLE & RELIABLE All materials expand and contract when exposed to extreme temperatures. In these types of conditions, Fibrex material performs twice as well as vinyl, which can bow and crack over time. EXCELLENT INSULATOR The built-in thermal qualities of Fibrex material mean that less heat and cold get transferred through the product into your customers’ homes. As an insulator, it’s on par with vinyl and far superior to aluminum. MOISTURE RESISTANT Because Fibrex material combines wood fiber and a special polymer formula, water has a tough time penetrating. The result is an increased resistance to rot. Thermal Expansion Fibrex® Material 1.0 3.0 2.0 4.0 0 Vinyl Pine Aluminum 1.57 3.42 1.18.25In / I n ° F x 1 0 -5 Thermal Conductivity Fibrex® Material 0.3 0.9 0.6 1.2 0 Vinyl Pine Aluminum .13 .10 .07 92.00 BT U / h r . f t . ° F Decay of Materials Fibrex® Material 10 30 20 40 50 0 Vinyl Treated Pine Untreated Pine 0%10%0% 50% % W e i g h t L o s s D u e t o D e c a y HEAT RESISTANT Fibrex material can withstand temperatures in excess of 150°F, even for dark colors, making it a great fit for your projects in hot climates. 800,000 1,200,000 Stiffness 807,600 1,213,000 6 WINDOW & DOOR TYPES Available in custom sizes to fit all projects. GLIDING WINDOWS Gliding windows have one stationary sash and one operating sash that glides horizontally. A three-sash configuration, where two sash glide past a fixed center sash, is also available. CASEMENT & AWNING WINDOWS Casement windows are hinged on the side and open outward to the left or right, while awning windows are hinged at the top and open outward. Both are also available as non-operating stationary windows. SINGLE-HUNG WINDOWS Single-hung windows feature a fixed upper sash with an operable lower sash that slides up and down. For convenience, the hardware locks automatically when the window is closed. An arch single-hung is also available to add architectural interest. Picture With Flanking Casements Twin Casement Gliding Stationary-Active Gliding Active-Stationary Gliding Active-Stationary-Active, 1:1:1 Sash Ratio Gliding Active-Stationary-Active, 1:2:1 Sash Ratio Arch Single-HungTwin Single-Hung Picture With Flanking Single-Hungs 7 GLIDING PATIO DOORS Patio doors feature one stationary panel and one operating panel that glides smoothly on adjustable rollers. They feature a multi-point locking system for enhanced security and an optional exterior keyed lock for convenience. Sidelights and transoms are also available. PICTURE, TRANSOM & SPECIALTY WINDOWS Choose from a variety of shapes to make a signature statement or provide a delicate lighting accent. Shapes include picture, transom, half circle, quarter circle, circle, Springline™ and arch windows. Custom shapes are also available, including unequal leg arch, trapezoid, pentagon, octagon and triangle windows. 8 FIBREX® MATERIAL STRONG ON PERFORMANCE. 9 Dimensions in parenthesis are in millimeters. Insert1-3/8" Flange Setback NO Flange1" Flange Setback No Flange Insert FRAME TYPES: 13/8" Flange Setback or 1" Flange Setback With Stucco Key For new construction, both frames have an integral installation flange that makes installation into a new opening easy and helps make sure the windows and doors are weathertight. For stucco exteriors, choose the frame with the stucco key to eliminate gaps that can result from the natural contraction of exterior stucco. REMODELING & REPLACEMENT Whether you're adding or updating, Andersen® 100 Series windows and patio doors enhance any project with a variety of styles, shapes and colors, with custom sizing in 1/8" (3) increments. The no-flange frame options include pre-drilled, through-the-jamb installation holes and installation screws to save you time. FRAME TYPES: No Flange or Insert The no flange frame allows for full removal of an existing window in situations where the frame is rotten or damaged. The no flange window is then installed into the existing rough opening. The insert frame provides fast and easy window replacement when installing the window into an existing window frame without disturbing the interior or exterior trim, saving time and money. The exterior accessory kerf allows for convenient finishing of the window. An exterior sill extender is available to fill the gap at the sill. Exterior frame extenders and a head expander are also available. • 3 1/8" (79) uniform sight lines allow for easy specification. • An extension jamb attachment flange is available for easy application of extension jambs on the job site. • Single-hung drywall pass-through windows have an upper sash that can be easily removed on the job site after the window is installed. With both sash removed, drywall can easily fit through upper floor windows. Single-Hung Gliding Casement 3 1/8" NEW CONSTRUCTION You’ll find a 100 Series window or door to match any project from commercial to residential — no matter the location. And with uniform sight lines, it's easy to specify 100 Series products for the entire project. 1 3/8" (35) Flange Setback 1" (25) Flange Setback With Stucco Key Insert1-3/8" Flange Setback NO Flange1" Flange Setback 1 3/8" (35) 1-3/8" Flange Setback 1" Flange Setback Stucco Key 1" (25) No Installation Flange Insert1-3/8" Flange Setback NO Flange1" Flange Setback Sill Extender Accessory Kerf 10 *Products with Sandtone, dark bronze and black interiors have matching exteriors. Printing limitations prevent exact duplication of colors. See your Andersen supplier for actual color samples. Dark Bronze *Dark Bronze* Black *Black* TerratoneSandtone *Sandtone* White White EXTERIOR COLORS INTERIOR COLORS EXTERIOR & INTERIOR COLORS 100 Series windows and patio doors come in five exterior colors, including dark bronze and black – colors that are darker and richer than those of most vinyl windows. The interiors feature a premium matte finish for an attractive appearance. 11 Printing limitations prevent exact replication of colors and finishes. See your Andersen supplier for actual color and finish samples. HARDWARE Casement & Awning Windows Folding handles avoid interference with window treatments. Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Antique Brass | Black Bright Brass | Satin Nickel Exterior handle matches the door’s exterior color. Interior handle matches the door’s interior color. Dark bronze exterior and white interior shown. Optional auxiliary foot lock is available to secure the gliding panel and provides an extra measure of security when the door is in a locked position. See page 92. Exterior Interior Exterior TULSA AFTON Interior Standard Handle Optional Handle Bold name denotes finish shown. Single-Hung & Gliding Windows Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Hardware color matches the window’s interior color. Shown in white. Standard Lock Optional Lift/Pull Optional Metal Slim Line Lock Bold name denotes finish shown. Both lock styles automatically engage when window is closed. Gliding Patio Doors 12 Center of glass performance only. Ratings based on glass options as of January 2022. Visit andersenwindows.com/energystar for ENERGY STAR map and NFRC total unit performance data. “ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. Stainless Steel GLASS OPTIONS Andersen has the glass you need to get the performance you want, with options for every climate, project and customer. Check with your supplier for the selections that meet ENERGY STAR® requirements in your area. For more details on our glass options, visit andersenwindows.com/glass. HEATLOCK TECHNOLOGY Applied to the room-side glass surface, HeatLock coating reflects heat back into the home for improved performance. ADDITIONAL GLASS OPTIONS Tempered safety glass is standard on patio doors and required for larger window sizes. Patterned glass lets in light while obscuring vision and adds a unique, decorative touch. Cascade and Reed patterns can be ordered with either a vertical or horizontal orientation. TIME-SAVING FILM We protect our products during delivery and construction with translucent film on the glass that peels away for a virtually spotless window. Cascade ObscureFern Reed Satin Etch Black ENERGY LIGHT How well a product blocks heat caused by sunlight. Visible Light Transmittance How much visible light comes through a product. UV Protection How well a product blocks ultraviolet rays.GLASS How well a product prevents heat from escaping. Solar Heat Gain CoefficientU-Factor lllm lmmm llmm lmmm lllm llmm lllm llll lmmm lllm llmm llmm lmmm mmmm llll mmmmHigh visibility with basic thermal performance. Ideal for northern, passive solar construction applications where solar heat gain is desired. Applied to the room-side surface, it reflects heat back into the home and improves U-Factor values. Outstanding thermal control in southern climates where less solar heat gain is desired. Applied to the room-side surface, it reflects heat back into the home and improves U-Factor values. PassiveSun with HeatLock Coating Clear Dual-Pane PassiveSun® Sun lllm llll llmm llll lllm llll llmm llll Applied to the room-side surface, it reflects heat back into the home and improves U-Factor values. Thermal control similar to tinted glass, with visible light transmittance similar to Low-E glass. SmartSun with HeatLock® Coating SmartSun™ Low-E with HeatLock Coating Low-E Outstanding overall performance for climates where both heating and cooling costs are a concern. lllm lllm llmm lllm lllm lllm lllm lllm GLASS SPACER OPTIONS In addition to stainless steel glass spacers, black glass spacers are now available as a standard offering to provide another way to customize project designs and achieve a contemporary style. Black glass spacers blend in with the color of the window or door for a sleek design, or serve as a shadow line. Add full divided light grilles, and the grille spacer bar between the glass will match the selected glass spacer color. 13 *Specify number of same-size rectangles across or down. Dimensions in parentheses are in millimeters. GRILLE OPTIONS Grilles for Andersen® 100 Series windows and patio doors are available in a wide variety of patterns to complement virtually any style of home. Plus, they have options for easy cleaning and architectural authenticity many vinyl windows can’t match. FULL DIVIDED LIGHT Permanently applied to the exterior and interior of the window, with a spacer between the glass. SIMULATED DIVIDED LIGHT Permanently applied to the exterior and interior of the window, with no spacer between the glass. FINELIGHT™ GRILLES BETWEEN-THE-GLASS Make glass easy to clean and have an elegant, sculpted profile. Choose a two-sided color scheme to match both the interior and exterior of the window or patio door. Also available with exterior grilles to provide architectural style and detail. Permanent exterior and permanent interior grilles with spacer Permanent exterior and permanent interior grilles with no spacer Finelight grilles- between-the-glass Finelight grilles- between-the-glass with permanent exterior grilles To see all of the standard patterns available for a specific window or door, refer to the detailed product sections in this product guide or contact your Andersen supplier. Prairie A Colonial Tall Fractional Short Fractional Specified Equal Light* Grille Patterns Custom Grille Bar Widths A 2 1/4" (57) width profile is available for most units to simulate a meeting rail or a multi-unit combination, such as a transom over a window or patio door. 3/4" (19) width grille bar for windows. 1" (25) width grille bar for patio doors. 1” Doors 3/4” Windows 2 1/4” Full Divided Light Grille Simulated Check Rail Casement Only 2 1/4” Simulated Divided Light Simulated Check Rail Casement Only 2 1/4” Simulated Check Rail 1” Doors 3/4” Windows 2 1/4” Full Divided Light Grille Simulated Check Rail Casement Only 2 1/4” Simulated Divided Light Simulated Check Rail Casement Only 2 1/4” Simulated Check Rail Actual width shown. 1” Doors 3/4” Windows 2 1/4” Full Divided Light Grille Simulated Check Rail Casement Only 2 1/4” Simulated Divided Light Simulated Check Rail Casement Only 2 1/4” Simulated Check Rail INSECT SCREEN OPTIONS Insect screens for venting windows have a fiberglass screen mesh. Optional TruScene® insect screens are made with a micro-fine stainless steel mesh, providing 50% greater clarity than our conventional insect screens. Insect screen frames for casement and awning windows are color matched to the product interior and for single-hung and gliding windows are matched to the product exterior. Gliding insect screens for 2-panel gliding patio doors have a fiberglass screen mesh. Insect screen frames for doors are color matched to the product exterior. 14 *69% of 156 builders/general contractors in a 2018 survey said they could reduce the number of installers by half using the Easy Connect Joining System when comparing the installation of a 12' (3658) wide x 8' (2438) high pre-assembled window combination unit with four 3' (914) wide x 8' (2438) high window combination units. **When installed according to Andersen installation instructions. Dimensions in parentheses are in millimeters. AN EASIER WAY TO BUILD BIGGER VIEWS Our unique reinforced joining systems make it easier for you to design and install large window combinations in your projects. These systems use strong, fiberglass construction and can be joined at our factory, on the job site, or even within a rough opening — wherever works best for you. This way you can easily and confidently build bigger views for your customers. Non-reinforced joining options include factory-joined combinations or field joining kits. For more information, visit andersenwindows.com/joining. A B C D 1 2 3 4 A B C D E F G H 1 2 3 4 A B C D E F G H 1 2 3 4 1 2 A B E F 3 4 C D G H 1 2 3 4 Innovative patented reinforced joining system utilizes 5 1/8" (130) interlocking fiberglass joining plates. A 1 E B 2 F C 3 G D 4 H 1 2 3 4 A B C D E F G H 1 2 3 4 A B C D E F G H 1 2 3 4 1 2 A B E F 3 4 C D G H 1 2 3 4 Reinforced Easy Connect Joining System Receive lighter, easier-to-handle, pre-assembled smaller combinations that join as you install them into the rough opening, making it easier to install large combinations. In fact, most contractors surveyed said they could reduce the number of installers by 50% using the Andersen Easy Connect Joining System.* Reinforced Factory-Joined Combinations Eliminate the need for job site assembly and receive fully joined, factory-assembled window combinations to fit rough openings up to 12' (3658) x 8' (2438) or 8' (2438) x 12' (3658). Appearance of a reinforced join. Appearance of a non-reinforced join. ASSEMBLY READY TO INSTALL NUMBER OF INSTALLERS* HALLMARK CERTIFIED** TESTED TO AAMA 450 PERFORMANCE COMBINATION SIZE LIMITATIONS REINFORCED FACTORY-JOINED COMBINATIONS FACTORY l MORE l l EXTENSIVE UNIT COMBINATION SIZE OPTIONS AVAILABLE CERTIFIED TO PG50** MAX. JOIN LENGTH: 12' MAX. JOINED COMBINATION: 12' x 8' or 8' x 12' 96 sq. ft. or 8.92 m2 REINFORCED JOINING KITS JOB SITE MORE l l EXTENSIVE UNIT COMBINATION SIZE OPTIONS AVAILABLE CERTIFIED TO PG50** MAX. JOIN LENGTH: 12' MAX. JOINED COMBINATION: 16' x 9' or 12' x 12' 144 sq. ft. or 13.34 m2 REINFORCED FACTORY-PREPPED EASY CONNECT JOINING SYSTEM IN THE OPENING l FEWER l l EXTENSIVE UNIT COMBINATION SIZE OPTIONS AVAILABLE CERTIFIED TO PG50** MAX. JOIN LENGTH: 12' MAX. JOINED COMBINATION HEIGHT: 16' NO MAXIMUM WIDTH NON-REINFORCED FACTORY-JOINED COMBINATIONS FACTORY l MORE l l EXTENSIVE UNIT COMBINATION SIZE OPTIONS AVAILABLE CERTIFIED UP TO PG50** MAX. JOIN LENGTH: 8' MAX. JOINED COMBINATION: 12' x 8' or 8' x 12' 96 sq. ft. or 8.92 m2 NON-REINFORCED JOINING KITS JOB SITE MORE l l EXTENSIVE UNIT COMBINATION SIZE OPTIONS AVAILABLE CERTIFIED UP TO PG50** MAX. JOIN LENGTH: 8' MAX. JOINED COMBINATION: 12' x 8' or 8' x 12' 96 sq. ft. or 8.92 m2 Reinforced & Non-Reinforced Interiors *Visit andersenwindows.com/warranty for details. **Products with Sandtone, dark bronze and black interiors have matching exteriors. Dimensions in parentheses are in millimeters. Printing limitations prevent exact replication of colors and finishes. See your Andersen supplier for actual color and finish samples. FRAME A The frame is constructed with Fibrex® composite material. This construction produces a rigid frame. B Durable, low-maintenance finish won’t fade, flake, blister or peel.* Factory-assembled doors arrive at the job site ready to install. C Dual felt weatherstrip, applied on the inside pocket of both side jambs and the head jamb, creates a positive seal between the frame and panels. The result is a long-lasting,* energy-efficient barrier against wind, water and dust. A full-length combination weatherstrip/interlock system provides a flexible seal at the meeting stile. Three frame options include: • 1 3 ⁄8" (35) flange setback for siding applications. An integral rigid vinyl flange helps seal the unit to the structure. • 1" (25) flange setback with stucco key. An integral rigid vinyl flange helps seal the unit to the structure. • No-flange option for door replacement in an existing framed opening. PANEL D Fibrex material construction provides long-lasting performance.* The panel, finished with a durable capping, provides maximum protection and a matte, low-maintenance finish. E Dual corrosion-resistant* ball- bearing rollers on the operating door panel provide smooth operation with self-contained leveling adjusters. The rollers have deep grooves to increase engagement with the roller track and resist lateral movement. Metal reinforcement inserted into the panel stiles provides additional stability. SILL F The one-piece sill design with weep holes located on the sill exterior provides superior water management. The heavy-gauge PVC construction is wear resistant and neutral gray in color. G The roller track has a stainless steel cap that resists denting for smooth, reliable operation. GLASS A glazing bead and silicone provide superior weathertightness and durability. H High-Performance options include: • Low-E SmartSun™ tempered glass • Low-E SmartSun HeatLock® tempered glass • Low-E tempered glass • Low-E HeatLock tempered glass • Low-E Sun tempered glass • Low-E PassiveSun® tempered glass • Low-E PassiveSun HeatLock tempered glass • Clear Dual-Pane tempered glass Additional glass options are available. Contact your Andersen supplier. A removable translucent film helps shield the glass from damage during delivery and construction, and simplifies finishing at the job site. Patterned Glass Patterned glass options are available. See page 12 for more details. Glass Spacers Glass spacers are now available in black, in addition to stainless steel, to provide more ways to customize project designs and achieve a contemporary look. (E-Series window is shown above.) HARDWARE Locking System A two-point locking system engages a steel receiver plate that’s secured into the side jamb. This provides enhanced security and a weathertight seal, with the operating panel pulled tightly into the jamb. G EF D Dark **Bronze** Dark Bronze BlackSandtoneTerratone COLOR OPTIONS White EXTERIOR COLORS **Black****Sandtone**White INTERIOR COLORS FEATURES GLIDING PATIO DOORS Black glass spacer A B C H HARDWARE Antique Brass | Black Bright Brass | Satin Nickel Exterior handle matches the door’s exterior color. Interior handle matches the door’s interior color. Dark bronze exterior and white interior shown.Bold name denotes finish shown. ACCESSORIES Sold Separately HARDWARE Auxiliary Foot Lock Provides an extra measure of security when the door is in a locked position. Available in colors that coordinate with the interior. GRILLES Grilles are available in a variety of configurations. See page 13 for details. INSECT SCREENS Insect screens have charcoal gray fiberglass screen mesh. The latch mechanism is contained within the insect screen handle for easy operation. Frames are available in colors to match the door exterior. SIDELIGHTS & TRANSOMS Patio door sidelights and transoms are available. See pages 95-96. Antique Brass Bright Brass Black Satin Nickel AFTON HARDWARE FINISHES Finishes shown are for Afton hardware only. Exterior Interior TULSA AFTON Exterior Standard Handle Optional Handle Interior 92 PATIO DOORS Insert window shown with exterior frame extenders and sill extender in dark bronze. Optional accessories are available for the installation of Andersen® windows and patio doors. Keep instruction guidelines and safety information in mind when considering the installation and use of any Andersen product. For questions, contact your local Andersen supplier. FIBREX® TRIM BOARD Available in white, canvas, prairie grass, Sandtone, Terratone, cocoa bean, dark bronze, red rock, forest green, dove gray and black, this solid cellular Fibrex trim board can be cut or ripped to size, and can be fastened using nails or screws. 3 1⁄2" (89) x 3 ⁄4" (19) thick in 10' (3048) lengths. COLOR-MATCHED SEALANT Color-matched sealant is available in Andersen exterior colors. This high- quality sealant can be used during the installation of all Andersen products. VINYL CHANNELS Rigid vinyl “J” and “h” channels are available in white, Sandtone and Terratone. “J” and “h” channels are 1⁄2" (13) deep and come in 150" (3810) lengths. “J” channels are 3 ⁄4" (19) wide and “h” channels are 1" (25) wide. “H” channels are 3 ⁄4" (19) deep and come in 84" (2134) and 150" (3810) lengths. White “H” channels are 3 ⁄4" (19) wide. Sandtone and Terratone “H” channels are 1" (25) wide. DRIP CAP Heavy 24-gauge corrosion-resistant aluminum construction in two profiles to match frames. Available in white, canvas, Sandtone, Terratone, dark bronze, forest green and black in 6' (1829), 10' (3048) and 12'-7 1⁄2" (3848) lengths. AUXILIARY CASING Made of cellular Fibrex material. Available in white, canvas, Sandtone, Terratone, dark bronze, forest green and black. 1 3 ⁄16" (30) x 1 3 ⁄16" (30) thick in 150" (3810) lengths. COIL STOCK Andersen aluminum coil stock can be ordered in white, canvas, prairie grass, Sandtone, Terratone, cocoa bean, dark bronze, red rock, forest green, dove gray and black. Made from .018" thick aluminum, coil stock is available in 24" (610) x 50' (15240) rolls. Color- matched 1 1⁄4" (32)-long stainless steel trim nails are also available and can be ordered in 1 lb/454 kg boxes. INSTALLATION ACCESSORIES FOR INSERT WINDOWS INSTALLATION ACCESSORIES FOR WINDOWS & DOORS EXTERIOR SILL EXTENDER A sill extender fits into the exterior accessory kerf in the window frame to hide the gap between the new insert window and the existing window frame at the sill. Precut to fit a 14° sill slope, it can be cut to fit other slopes as needed. Available in all exterior colors. Shown in white. HEAD EXPANDER A head expander assists in filling the opening at the top of the window when doing an interior installation. Available in white. EXTERIOR FRAME EXTENDERS Frame extenders fit into the exterior accessory kerf in the frame to hide the gap around the sides and/or head between the new insert window and the existing window frame. Extenders can be cut to length as needed. Available in all exterior colors. Shown in dark bronze. Exterior frame and sill extenders are available in long lengths or can be ordered cut to approximate lengths for convenience at the job site. COIL STOCK Coil stock fits into the exterior accessory kerf in the window frame, then wraps the existing wood window trim. It can be cut and formed to profiles at the job site. Andersen aluminum coil stock can be ordered white, canvas, prairie grass, Sandtone, Terratone, cocoa bean, dark bronze, red rock, forest green, dove gray and black. Made from .018" thick aluminum, coil stock is available in 24" (610) x 50' (15240) rolls. Color- matched 1 1 ⁄4" (32) stainless steel trim nails are also available and can be ordered in 1 lb/.454 kg boxes. COLOR-MATCHED SEALANT Color-matched sealant is available in Andersen exterior colors and is specially formulated to adhere to Andersen products. FOAM BACKER ROD Available for installations, 3 ⁄8" (10) backer rod helps provide an air seal around the frame. Available in 100' (30480) rolls. SHIMS Flat self-hanging shims help with a secure installation. Available in boxes of 248 shims. 109 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES GROUND FLOOR 306'-11" SECOND FLOOR 320'-0" T/FOOTING 289'-11" THIRD FLOOR 329'-7" FOURTH FLOOR 339'-2" PARAPET 352'-10 5/8" T/ROOF FRAMING 348'-10 5/8" A B C E PARKING LEVEL 294'-11" D T/STAIR TOWER 356'-10 5/8" 4' - 0 " 4' - 0 " 9' - 8 5 / 8 " 9' - 7 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " 5' - 0 " A-310 3 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no. revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 11 / 1 0 / 2 0 2 0 1 0 : 4 4 : 3 1 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ j b c o e . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-301 11.09.2020 BUILDING SECTIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 HCR Submission JBC 20082 - JLB/JBC 2018 0'8'4'16'24' SCALE : 1/8" = 1'-0" SCALE: 1/4" = 1'-0" 1 BUILDING SECTION - AA GROUND FLOOR 0" SECOND FLOOR 13'-1" T/FOOTING -17'-0" THIRD FLOOR 22'-8" FOURTH FLOOR 32'-3" T/ PARAPET 46'-8" PARKING LEVEL -12'-0" 9' - 7 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " 5' - 0 " 63 ' - 8 " CORRIDOR 109 CORRIDOR 204 CORRIDOR CORRIDOR PARKING EXCELSIOR AVENUE A-310 3 3 BEDROOM UNIT 3 BEDROOM UNIT 3 BEDROOM UNIT 2 BEDROOM UNIT 1 BEDROOM UNIT 1 BEDROOM UNIT 1 BEDROOM UNIT UNEXCAVATED COMMUNITY ROOM 112 A B C FDEB.5 A-312 1 F2 F3 F3 R1 F0 F5 T/ PL - 4TH FLR 40'-5" F3F3 F3 F3 1/4" / 12"1/4" / 12" 6' - 3 " 8' - 2 " SIGH T L I N E E X C E L S I O R A V E N U E , N O R T H E D G E SIGHTLIN E R O U T E 5 0 . L E F T N - B O U N D L A N E SIGHTL I N E B I K E P A T H 4' - 9 " 3' - 6 " TALLEST HEATPUMP ON 18" STAND. 3rd & 4th FLOOR HEAT PUMPS ON ROOF BETWEEN STAIRWELLS 1st & 2nd FLOOR HEAT PUMPS ON WALL OF PARKING LEVEL 7' - 1 1 1 / 2 " 7' - 1 1 1 / 2 " SIGH T L I N E E X C E L S I O R A V E N U E , N O R T H E D G E SIGHTLIN E R O U T E 5 0 . L E F T N - B O U N D L A N E SIGHTL I N E B I K E P A T H Aegis A-W Heatpump on 16" Curb 06.15.2026 75% CONSTRUCTION DOCUMENTS NEW GROUND FLOOR 306'-11" SECOND FLOOR 320'-0" T/FOOTING 289'-11" THIRD FLOOR 329'-7" FOURTH FLOOR 339'-2" PARAPET 352'-10 5/8" T/ROOF FRAMING 348'-10 5/8" A B C E PARKING LEVEL 294'-11" D T/STAIR TOWER 356'-10 5/8" 4' - 0 " 4' - 0 " 9' - 8 5 / 8 " 9' - 7 " 9' - 7 " 13 ' - 1 " 12 ' - 0 " 5' - 0 " 54 ' - 9 1 / 8 " Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 3 : 2 5 : 4 4 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-301 05.26.2021 BUILDING SECTIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 - JLB/JBC 2021 0'8'4'16'24' SCALE : 1/8" = 1'-0" SCALE:1/4" = 1'-0"2 BUILDING SECTION - AA SIGH T L I N E E X C E L S I O R A V E N U E , N O R T H E D G E SIGHTLIN E R O U T E 5 0 . L E F T N - B O U N D L A N E SIGHTL I N E B I K E P A T H 9' - 6 " 6' - 6 " TALLEST HEATPUMP ON 18" STAND. 3rd & 4th FLOOR HEAT PUMPS ON ROOF BETWEEN STAIRWELLS 1st & 2nd FLOOR HEAT PUMPS ON WALL OF PARKING LEVEL 15 ' - 1 1 " 15 ' - 1 1 " HVAC PREVIOUS SUBMISSION OLD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 3022 1 2 3 4 5 6 7 8 9 06 01 07 0311 24 25 26 27 28 29 30 08 04 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 1 0 : 2 9 : 2 3 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-202 07.21.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" A SOUTH ELEVATION 0'-2 1/2" 7' - 9 " EA 0'-8" OA TYPICAL 3 BR END APARTMENT TYPICAL 3 BR APARTMENT 0'-3"0'-7 1/2" 8' - 7 " 8' - 7 " 8' - 7 " EA OAKE ON PERPENDICULAR WALL HIDDEN FROM VIEW LEGEND EA - 8"x8" EXHAUST AIR , FROM APT BATHROOMS OA - 8"x8" APT OUTSIDE AIR INTAKE KE - 8"x8" APT KITCHEN EXHAUST OA1 - 30"x18" OUTDOOR AIR LOUVER OA2 - 42"x18" OUTDOOR AIR LOUVER 9' - 6 " 5'-0" OA1 OA2 OA2OA1OA1 9' - 6 " 5'-0" HVAC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 3022 1 2 3 4 5 6 7 8 9 06 01 07 0311 24 25 26 27 28 29 30 08 04 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 1 0 : 2 9 : 2 3 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-202 05.26.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" A SOUTH ELEVATION 0'-2 1/2" 7' - 9 " EA 0'-8" OA TYPICAL 3 BR END APARTMENT TYPICAL 3 BR APARTMENT 0'-3"0'-7 1/2" 8' - 7 " 8' - 7 " 8' - 7 " EA OAKE ON PERPENDICULAR WALL HIDDEN FROM VIEW LEGEND EA - 8"x8" EXHAUST AIR , FROM APT BATHROOMS OA - 8"x8" APT OUTSIDE AIR INTAKE KE - 8"x8" APT KITCHEN EXHAUST OA1 - 30"x18" OUTDOOR AIR LOUVER OA2 - 42"x18" OUTDOOR AIR LOUVER 9' - 6 " 5'-0" OA1 OA2 OA2OA1OA1 9' - 6 " 5'-0" HVAC PREVIOUS SUBMISSION 123456789101112131415161718192021232425262728293022 52 ' - 9 " ± 24252627282930 01 04 08 121314151617181920 16 07 09 15 10 05 11 1718 09 1234 06 02 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 7/ 2 0 / 2 0 2 1 9 : 3 3 : 3 0 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-201 07.21.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" A NORTH ELEVATION TYPICAL 1 BR APARTMENT TYPICAL 2 BR APARTMENT 1'-4" 7' - 9 " KE TYPICAL 3 BR APARTMENT 1'-0" KE EAOA 1'-9"1'-0" KE EAOA 1'-9" 7' - 9 " 0'-10" 8' - 7 " LEGEND EA - 8"x8" EXHAUST AIR, FROM APT BATHROOMS OA - 8"x8" APT OUTSIDE AIR INTAKE KE - 8"x8" APT KITCHEN EXHAUST HVAC 123456789101112131415161718192021232425262728293022 52 ' - 9 " ± 24252627282930 01 04 08 121314151617181920 16 07 09 15 10 05 11 1718 09 1234 06 02 Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 1 0 : 4 2 : 5 1 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-201 05.26.2021 BUILDING ELEVATIONS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission JBC 20082 -- JLB/JBC 2021 SCALE: 1/16" = 1'-0" A NORTH ELEVATION TYPICAL 1 BR APARTMENT TYPICAL 2 BR APARTMENT 1'-4" 7' - 9 " KE TYPICAL 3 BR APARTMENT 1'-0" KE EAOA 1'-9"1'-0" KE EAOA 1'-9" 7' - 9 " 0'-10" 8' - 7 " LEGEND EA - 8"x8" EXHAUST AIR, FROM APT BATHROOMS OA - 8"x8" APT OUTSIDE AIR INTAKE KE - 8"x8" APT KITCHEN EXHAUST HVAC PREVIOUS SUBMISSION NOT FOR CONSTRUCTION no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ h w \ D o c u m e n t s \ R E V I T L O C A L \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6_ N o D a y c a r e _ H a n n a h W a m b a c h . r v t 6 / 3 0 / 2 0 2 6 1 1 : 0 3 : 2 4 A M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 RENDERINGS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-901 75% CONSTRUCTION DOCUMENTS Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 10 / 1 3 / 2 0 2 0 9 : 2 5 : 4 5 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ f a f . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-901 10.09.2020 RENDERINGS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission - 20082 -- JLB/JBC 2018 OLD PREVIOUS SUBMISSION Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 3 / 2 0 2 1 1 0 : 3 3 : 4 1 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-901 07.07.2021 RENDERINGS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission - 20082 -- JLB/JBC 2021 PREVIOUS SUBMISSION NOT FOR CONSTRUCTION no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ h w \ D o c u m e n t s \ R E V I T L O C A L \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6_ N o D a y c a r e _ H a n n a h W a m b a c h . r v t 6 / 3 0 / 2 0 2 6 1 1 : 0 2 : 2 5 A M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 RENDERINGS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-902 75% CONSTRUCTION DOCUMENTS Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 10 / 1 3 / 2 0 2 0 9 : 2 5 : 4 7 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ f a f . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-902 10.09.2020 RENDERINGS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission - 20082 -- JLB/JBC 2018 OLD PREVIOUS SUBMISSION Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 2 / 2 0 2 1 5 : 1 4 : 0 0 P M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t ARCHITECTURE Be a c o n C o m m u n i t i e s , L L C A-902 07.07.2021 RENDERINGS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission - 20082 -- JLB/JBC 2021 PREVIOUS SUBMISSION NOT FOR CONSTRUCTION no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE 69 State Street, Suite 1400B Albany, NY 12207 315.253.7301 ALBANY Fi l e n a m e : Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © 115 Solar St Syracuse, NY 13204 315.472.6980 SYRACUSE C: \ U s e r s \ h w \ D o c u m e n t s \ R E V I T L O C A L \ B E A R - A - 2 0 0 8 2 - V 2 0 2 6_ N o D a y c a r e _ H a n n a h W a m b a c h . r v t 6 / 3 0 / 2 0 2 6 1 1 : 0 0 : 1 8 A M ARCHITECTURE BE A C O N C O M M U N I T I E S , L L C 06.15.2026 RENDERINGS EX C E L S I O R A P A R T M E N T S EX C E L S I O R A V E N U E , SA R A T O G A S P R I N G S N Y , 1 2 8 6 6 NGS 20082 NGS/JLB JLB 2025 A-903 75% CONSTRUCTION DOCUMENTS Beardsley Design Associates Architecture, Engineering, Landscape Architecture, D.P.C. © Fi l e n a m e : NO T F O R C O N S T R U C T I O N no.revision description by date Project Number: Drawn By: Designed By: Reviewed By: WARNING Any alterations to this document not conforming to section 7307. New York State Education Law are strictly prohibited. 320 West Main Street Malone, NY 12953 518.483.1585 5789 Widewaters Pkwy Dewitt, NY 13214 315.472.6980 64 South Street Auburn, NY 13021 315.253.7301 AUBURN MALONE SYRACUSE 150 State Street, 4th Floor Albany, NY 12207 315.253.7301 ALBANY 6/ 2 3 / 2 0 2 1 1 0 : 3 3 : 4 1 A M C: \ P r o j e c t s \ B E A R - A - 2 0 0 8 2 - V 2 0 2 1 _ s f o l t s 2 N W E Q . r v t Be a c o n C o m m u n i t i e s , L L C A-903 07.07.2021 RENDERINGS Ex c e l s i o r P a r k A f f o r d a b l e H o u s i n g Ex c e l s i o r A v e n u e , S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 DRC Submission Author 20082 Checker Designer 2021 PREVIOUS SUBMISSION Upgrade Your Expectations ARC LED Visually Comfortable Wall-Mounted Luminaires It’s time to upgrade your expectations when it comes to upgrading wall-mounted lighting. The all-new Lithonia Lighting® ARC LED wall-mounted luminaires combine visually comfortable illumination and architectural styling to create an affordable lighting upgrade that you can be proud of, while saving 80% in energy costs. No ugly fins, no blinding LED’s… ARC LED is your new best choice for wall-mounted luminaires. With two sizes and lumen packages ranging from 1,500 to 6,500 lumens, the ARC family is ideal for applications from over-the-door lighting to mounting heights of up to 15 feet. Emergency battery pack, photocell, CCT and finish options make the ARC configurable to meet the needs of any application. Since the ARC LED luminaires are made in North America, all these options are available with industry-leading quick delivery. Outdoor ARC1 ARC2 Quick Facts: ƒVisually comfortable optics ƒTwo sizes deliver 1,500 to 6,500 lumens ƒReplace 70W to 250W metal halide ƒIntegral photocell and battery pack options ƒ3000K, 4000K and 5000K CCT (80 CRI) ƒDLC Premium listed* ƒ5-year limited warranty * Not all options are DLC premium Visually Comfortable Optics Key Features Ordering Information One Lithonia Way, Conyers, GA 30012 | Phone: (800) 279-8014 | www.acuitybrands.com © 2020 Acuity Brands Lighting, Inc. All Rights Reserved. | LL_422627.04 Visit www.lithonia.com for more information Recessed diffused lens to cut off high angle light and reduce glare. Combination of diffused lens and reflector design has low surface brightness creating a visually comfortable environment with great distribution. LEDs are fully hidden from view to eliminate pixelization and harsh glare. NOTE: 1. 347V not available with E4WH and E8WC 2. E8WC only available on ARC2 3. FAO and DMG not available together ARC LED Series & Package Color Temperature Voltage Options Finish ARC1 LED 30K 3000K, 80 CRI MVOLT 120-277V E4WH Emergency battery backup, CEC compliant (4W, 0°C min) DDBXD Dark Bronze 40K 4000K, 80 CRI 3471 347V E8WC 2 Emergency battery backup, CEC compliant (8W, -20°C min) DNAXD Black 50K 5000K, 80 CRI PE Photocell, Button Type DNAXD Natural Aluminum FAO 3 Field adjustable output DWHXD White DDLBXD Textured Dark Bronze DMG3 0-10V dimming wires pulled outside fixture (for use with an external control, ordered separately) Consult factory for other finish options Clean look with no fins for a true architectural style that looks great on any building. Built-in wet location wiring compartment for applications with no existing junction box. ARC LED Wall-Mounted Luminaires DDBXD Dark Bronze DNAXD Black DNAXD Natural Aluminum DWHXD White DDLBXD Textured Dark Bronze DDLBXD Textured Black DNATXD Textured Natural Aluminum DWHGXD Textured White Emergency battery backup integrated into the luminaire housing for a clean aesthetic. Field adjustable light output device (allows for easy adjustment to the desired light levels, from 20% to 100%) P1 1,500 Lumens P2 2,000 Lumens P3 3,000 Lumens P1 1,500 Lumens P2 2,000 Lumens P3 3,000 Lumens P41 4,000 Lumens P5 6,500 Lumens ARC2 LED Project Name/Number/Date 07 42 43-1 Composite Wall Panels VintageWood Three-Part Specification 07 42 43 Composite Wall Panels Part I - General 1.1 SECTION INCLUDES: A. Exterior, panelized fiber cement cladding system and accessories to complete a drained and back-ventilated rainscreen. B. Interior fiber cement panelized cladding system and accessories. 1.2 RELATED SECTIONS A. Section 05 41 00 - Structural Metal Stud Framing B. Section 06 10 00 - Rough Carpentry C. Section 06 16 00 - Sheathing D. Section 07 20 00 - Thermal Protection E. Section 07 25 00 - Weather Barriers F. Section 07 60 00 - Flashing and Sheet Metal G. Section 07 90 00 - Joint Protection 1.3 REFERENCES A. American Architectural Manufacturers Association (AAMA): 1. AAMA 509-14 – Voluntary Test and Classification Method of Drained and Back Ventilated Rain Screen Wall Cladding Systems B. ASTM International (ASTM): 1. ASTM C 518 - Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. 2. ASTM C 1185 - Standard Test Methods for Sampling and Testing Non-Asbestos Fiber Cement. a. ASTM C 1186 – Standard Specification for Flat Fiber-Cement Sheets. 3. ASTM E-84 - Standard Test for Surface Burning Characteristics of Building Materials. 4. ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials. 5. ASTM E 228 - Standard Test Method for Linear Thermal Expansion of Solid Materials with a Vitreous Silica Dilatometer. Project Name/Number/Date 07 42 43-2 Composite Wall Panels 6. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 7. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. C. Florida Building Code - Test Protocol HVHZ 1. Testing Application Standard (TAS) 202, 203 – HVHZ Test Procedures D. National Fire Protection Association (NFPA): 1. NFPA 285 - Fire Test Method for Exterior Wall Assemblies Containing Combustible Material. 2. NFPA 268 – Ignition Resistance of Exterior Wall Assemblies. E. Standards Council of Canada & Underwriters Laboratories Canada (ULC): 1. CAN/ULC S-102 – Standard Method of Test for Surface Burning Characteristics. 2. CAN/ULC S-134 – Standard Method of Fire Test of Exterior Wall Assembly. 1.4 SUBMITTALS A. Submit under provisions of Section 01 33 00. B. Product Data: Submit manufacturer’s product description, storage and handling requirements, and installation instructions. C. Product Test Reports and Code Compliance: Documents demonstrating product compliance with local building code, such as test reports or Evaluation Reports from qualified, independent testing agencies. D. LEED Credits: Provide documentation of LEED Credits for project certification under USGBC LEED 2009 (Version 3.0) or 2012 v.4. E. Manufacturer’s Details: Submit drawings (.dwg, .rvt, and/or .pdf formats), including plans, sections, showing installation details that demonstrate product dimensions, edge/termination conditions/treatments, compression and control joints, corners, openings, and penetrations. F. Samples: Submit samples of each product type proposed for use. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: 1. All fiber cement panels specified in this section must be supplied by a manufacturer with a minimum of 10 years of experience in fabricating and supplying fiber cement cladding systems. a. Products covered under this section are to be manufactured in an ISO 9001 certified facility. Project Name/Number/Date 07 42 43-3 Composite Wall Panels 2. Provide technical and design support as needed regarding installation requirements and warranty compliance provisions. B. Installer Qualifications: All products listed in this section are to be installed by a single installer trained by manufacturer or representative. C. Mock-Up Wall: Provide a mock-up wall as evaluation tool for product and installation workmanship. D. Pre-Installation Meetings: Prior to beginning installation, conduct conference to verify and discuss substrate conditions, manufacturer’s installation instructions and warranty requirements, and project requirements. 1.6 DELIVERY, STORAGE, AND HANDLING A. Panels must be stored flat and kept dry before installation. A waterproof cover over panels and accessories should be used at all times prior to installation. Do not stack pallets more than two high. Refer to the information included on each pallet. B. If panels are exposed to water or water vapor prior to installation, allow to completely dry before installing. Failure to do so may result in panel shrinkage at ship lap joints, and such action may void warranty. C. Panels MUST be carried on edge. Do not carry or lift panels flat. Improper handling may cause cracking or panel damage. D. Direct contact between the panels and the ground should be avoided at all times. It is necessary to keep panels clean during installation process. 1.7 WARRANTY A. Provide manufacturer’s 15-year warranty against manufactured defects in fiber cement panels. Additional 5-year extension available when refinished in year 14-15. B. Provide manufacturer’s 15-year warranty against manufactured defects in panel finish. C. Warranty provides for the original purchaser. See warranty for detailed information on terms, conditions and limitations. PART II: PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Nichiha Corporation, 18-19 Nishiki 2-chome Naka-ku, Nagoya, Aichi 460-8610, Japan. Project Name/Number/Date 07 42 43-4 Composite Wall Panels B. Acceptable Manufacturer’s Representative: Nichiha USA, Inc., 6465 E. Johns Crossing, Suite 250, Johns Creek, GA 30097. Toll free: 1.866.424.4421, Office: 770.805.9466, Fax: 770.805.9467, www.nichiha.com. 1. Basis of Design Product: Nichiha VintageWood. a. Profile colors: Bark, Cedar, Redwood, Ash, and Spruce. b. Profiles: Wood plank texture with three, 3/8” grooves running lengthwise, spaced 5-5/8” apart. c. Accessory/Component Options: i. Manufactured Corners with 3-1/2” returns for each profile color. ii. Aluminum trim options: Corner Key, Open Outside Corner, H-Mold, J-Mold, Compression Joint, Inside Corner 1. Finish: Bark, Cedar, Clear Anodized, or Primed. iii. Essential Flashing System: Starter, Overhang. 1. Finish: Matte black. d. Dimensions: 1. AWP-1818: 455mm (17-7/8”) (h) x 1,818 mm (71-9/16”) (l). 2. AWP-3030: 455mm (17-7/8”) (h) x 3,030 mm (119-5/16”) (l). e. Panel Thickness: 16 mm (5/8"). f. Weight: AWP-1818: 35.27 lbs. per panel, AWP-3030: 57.32 lbs. per panel. g. Coverage: 8.88 sq. ft. per panel (1818), 14.81 sq. ft. per panel (3030). h. Factory sealed on six [6] sides. C. Substitutions: Not permitted. D. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00. 2.2 MATERIALS A. Fiber cement panels manufactured from a pressed, stamped, and autoclaved mix of Portland cement, fly ash, silica, recycled rejects, and wood fiber bundles. B. Panel surface pre-finished and machine applied. C. Panels profiled along 3030mm edges so that the long joints between the installed panels are ship-lapped. D. Factory-applied sealant gasket added to top panel edge; all 3030mm edge joints contain a factory sealant. Project Name/Number/Date 07 42 43-5 Composite Wall Panels 2.3 PERFORMANCE REQUIREMENTS: A. Fiber Cement Cladding – Must comply with ASTM C-1186, Type A, Grade II requirements: 1. Wet Flexural Strength: Result: 1418 psi, Lower Limit: 1015 psi. 2. Water Tightness: No water droplets observed on any specimen. 3. Freeze-thaw: No damage or defects observed. 4. Warm Water: No evidence of cracking, delamination, swelling, or other defects observed. 5. Heat-Rain: No crazing, cracking, or other deleterious effects, surface or joint changes observed in any specimen. B. Mean Coefficient of Linear Thermal Expansion (ASTM E-228): Max 1.0*10^-5 in./in. F. C. Surface Burning (CAN-ULC S102/ASTM E-84): Flame Spread: 0, Smoke Developed: 0. D. Wind Load (ASTM E-330): Contact manufacturer for ultimate test pressure data corresponding to framing type, dimensions, fastener type, and attachment clips. Project engineer(s) must determine Zone 4 and 5 design pressures based on project specifics. 1. Minimum lateral deflection: L/120. E. Water Penetration (ASTM E-331): No water leakage observed into wall cavity. F. Steady-State Heat Flux and Thermal Transmission Properties Test (ASTM C-518): 16mm thick panel thermal resistance R Value of 0.47. G. Fire Resistant (ASTM E-119): The wall assembly must successfully endure 60-minute fire exposure without developing excessive unexposed surface temperature or allowing flaming on the unexposed side of the assembly. H. Ignition Resistance (NFPA 268): No sustained flaming of panels, assembly when subjected to a minimum radiant heat flux of 12.5 kW/m2 ± 5% in the presence of a pilot ignition source for a 20-minute period. I. Fire Propagation (NFPA 285): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Commercial Wrap, ½” Densglass Gold Sheathing, 16” o.c. 18 gauge steel studs, mineral wool in-cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of NFPA 285. J. Fire Propagation (CAN/ULC S-134): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Housewrap, 5/8” FRT plywood, 16” o.c. 2x wood studs, fiberglass in- cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of CAN/ULC S-134. K. Drained and Back Ventilated Rainscreen (AAMA 509-14): System classifications: W1, V1. Project Name/Number/Date 07 42 43-6 Composite Wall Panels L. Florida Building Code - Test Protocol HVHZ (TAS 202, 203): Horizontal Application Design Pressure: 95 psf, Vertical Application Design Pressure: 85 psf. 2.4 INSTALLATION COMPONENTS A. Ultimate Clip System: 1. Starter Track: a. Horizontal Panel Installations - FA 700 – 3,030mm (l) galvalume coated steel. b. Vertical Panel Installations (AWP-3030 only) – FA 710T – 3,030mm (l) galvalume coated steel. 2. Panel Clips: JEL 778 “Ultimate Clip II” (10mm rainscreen for 16mm AWP) – Zinc- Aluminum-Magnesium alloy coated steel. a. Joint Tab Attachments (included) – used at all AWP-1818 panel to panel vertical joints, NOT used with AWP-3030 installations. 3. Corner Clips: JE 777C (10mm rainscreen for 5/8” AWP Manufactured Corners) -- Zinc-Aluminum-Magnesium alloy coated steel. 4. Single Flange Sealant Backer – FHK 1015 R (10mm) – 6.5’ (l) fluorine coated galvalume. 5. Double Flange Sealant Backer – FH 1015 R (10mm) – 10’ (l) fluorine coated galvalume. 6. Corrugated Spacer – FS 1005 (5mm), FS 1010 (10mm) – 4’ (l). B. Aluminum Trim (optional): Paint primed trim as specified in finish schedule. C. Essential Flashing System (optional): 1. Starter – main segments (3,030mm), inside corners, outside corners 2. Overhang – main segments (3,030mm), inside corners, outside corners, joint clips D. Fasteners: Corrosion resistant fasteners, such as hot-dipped galvanized screws appropriate to local building codes and practices must be used. Use Stainless Steel fasteners in high humidity and high-moisture regions. Panel manufacturer is not liable for corrosion resistance of fasteners. Do not use aluminum fasteners, staples or fasteners that are not rated or designed for intended use. See manufacturer’s instructions for appropriate fasteners for construction method used. Project Name/Number/Date 07 42 43-7 Composite Wall Panels E. Flashing: Flash all areas specified in manufacturer’s instructions. Do not use raw aluminum flashing. Flashing must be galvanized, anodized, or PVC coated. F. Sealant: Sealant shall comply with ASTM C920, Class 35. PART III: EXECUTION 3.1 EXAMINATION A. Verification of Conditions: 1. Fiber cement panels can be installed over braced wood, steel studs and sheathing including plywood, OSB, plastic foam (1” or less) or fiberboard sheathing. Fiber cement panels can also be installed over Structural Insulated Panels (SIP’s), Concrete Masonry Units (CMU’s) and Concrete Block Structures (CBS’s) with furring strips, and Pre- Engineered Metal Construction. Insulated Concrete Forms (ICFs) require added measures. Consult with Nichiha Technical Services. 2. Allowable stud spacing: 16” o.c. maximum. 3. A weather resistive barrier is required when installing fiber cement panels. Use an approved weather resistive barrier (WRB) as defined by the 2015 IBC or IRC. Refer to local building codes. 4. Appropriate metal flashing should be used to prevent moisture penetration around all doors, windows, wall bottoms, material transitions and penetrations. Refer to local building codes for best practices. B. Examine site to ensure substrate conditions are within alignment tolerances for proper installation. C. Do not begin installation until unacceptable conditions have been corrected. D. Do not install panels or components that appear to be damaged or defective. Do not install wet panels. 3.2 TOLERANCE A. Wall surface plane must be plumb and level within +/- ¼ inch in 20 feet in any direction. 1. One layer of Nichiha 5mm (~3/16”) Spacer may be used as shim. 3.3 INSTALLATION A. General: Install products in accordance with the latest installation guidelines of the manufacturer and all applicable building codes and other laws, rules, regulations and Project Name/Number/Date 07 42 43-8 Composite Wall Panels ordinances. Review all manufacturer installation, maintenance instructions, and other applicable documents before installation. 1. Consult with your local dealer or Nichiha Technical Department before installing any Nichiha fiber cement product on a building higher than 45 feet or three stories or for conditions not matching prescribed standard installation guide requirements and methods. A Technical Design Review (TDR) process is available to evaluate project feasibility. 2. Vertical Control/Expansion Joints are required with AWP-1818, for walls wider than 30 feet, within 2-12 feet of outside corners finished with metal trim and approximately every 30 feet thereafter. A. Vertical Control/Expansion Joints are required at each AWP-3030 vertical joint, or H-Mold trim may be used instead. 3. Horizontal/Compression Joints are required for multi-story installations of AWP. Locate joints at floor lines. Joints are flashed minimum ½” breaks. Do not caulk. Refer to installation guide(s). A. Wood framed buildings of three or more floors require a compression joint at each floor. B. Steel framed buildings (including reinforced concrete core with LGMF exterior walls) of more than three floors (or 45 feet) require a compression joint every 25 feet at a floor line. B. Panel Cutting 1. Always cut fiber cement panels outside or in a well ventilated area. Do not cut the products in an enclosed area. 2. Always wear safety glasses and NIOSH/OSHA approved respirator whenever cutting, drilling, sawing, sanding or abrading the products. Refer to manufacturer SDS for more information. 3. Use a dust-reducing circular saw with a diamond-tipped or carbide-tipped blade. a. Recommended circular saw: Makita 7-1/4” Circular Saw with Dust Collector (#5057KB). b. Recommended blade: Tenryu Board-Pro Plus PCD Blade (#BP-18505). c. Shears (electric or pneumatic) or jig saw can be used for complicated cuttings, such as service openings, curves, radii and scrollwork. 4. Silica Dust Warning: Fiber cement products may contain some amounts of crystalline silica, a naturally occurring, potentially hazardous mineral when airborne in Project Name/Number/Date 07 42 43-9 Composite Wall Panels dust form. Consult product SDS or visit https://www.osha.gov/dsg/topics/silicacrystalline/. 5. Immediately clean dust from cut panels as it may bind to the finish. 3.4 CLEANING AND MAINTENANCE A. Review manufacturer guidelines for detailed care instructions. I 100 SERIES 2024-25 PRODUCT GUIDE FOR PROFESSIONALS THAT ’S EASY ON THE BUDGET A MODERN LOOK WEB VERSION October 2025 CONTENTS Performance & Durability ............................................................. 2-3 Fibrex® Material ............................................................................. 4-5 Window & Door Types ................................................................. 6-7 Window Frame Options ............................................................... 8-9 Exteriors & Interiors ...........................................................................10 Hardware ........................................................................................... 11 Glass ................................................................................................... 13 Grilles & Insect Screens .................................................................. 14 Build Bigger Views ........................................................................... 16 100 SERIES WINDOWS Windows Overview ........................................................................ 17 Casement Windows ................................................................... 20 Awning Windows ........................................................................ 27 Single-Hung Windows .............................................................. 32 Gliding Windows ........................................................................ 55 Picture, Transom & Specialty Windows ................................ 68 100 SERIES PATIO DOORS Patio Doors Overview ..................................................................... 99 Gliding Patio Doors .................................................................. 101 Patio Door Sidelights & Transoms ........................................ 103 Combination Designs ................................................................... 107 Product Performance ..................................................................... 111 Installation Accessories & Information ..................................... 120 Sustainability .................................................................................... 123 For warranty information, visit andersenwindows.com/warranty. Andersen Corporation, including its subsidiaries, has been named a 2023 ENERGY STAR® Partner of the Year – Sustained Excellence Award winner, the highest honor given by ENERGY STAR, for continued leadership in protecting the environment through superior energy efficiency achievements.“ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. Throughout this product guide, when you see the arrow icon, click for more information. 1 AMERICA’S MOSTLOVED BRAND OF WINDOWS & DOORS* 100 SERIES PRODUCTS You want to give your customers a home they love, and we’re here to make that easy for you. That’s why we’re proud to offer you products that rate #1 in quality and performance,** and to be the #1 trusted and recommended window and door brand** by pros. The best way to give your customers a modern look that’s within budget and lasts.† The 100 Series product line is made from our proprietary Fibrex® material that’s energy efficient, environmentally responsible and stronger than vinyl. *2022 Andersen brand surveys of U.S. realtors, contractors, builders and homeowners. **2022 Andersen brand surveys of U.S. contractors, builders, architects and homeowners. †Visit andersenwindows.com/warranty for details. 2 COLORS THAT LAST Durable factory-finished interiors and exteriors never need painting and won’t fade, flake, blister or peel,* even in extreme cold or heat. ENERGY EFFICIENT IN EVERY CLIMATE Energy-efficient 100 Series products are available with options that make them ENERGY STAR® v. 7.0 certified throughout the U.S. so they can help reduce heating and cooling bills. Visit andersenwindows.com/energystar for more information and to verify that the product with your glass option is certified in your area. QUALITY SO SOLID, THE WARRANTY IS TRANSFERABLE* Many other window and door warranties end when a home is sold, but our coverage – 20 years on glass, 10 years on non-glass parts – transfers from each owner to the next. And because it’s not prorated, the coverage offers full benefits year after year, owner after owner. So it can add real value when you decide to sell your home. DESIGNED FOR PERFORMANCE 100 Series products are designed to meet or exceed performance requirements in all 50 states.† See pages 112-113 for details. PERFORMANCE 100 Series products simply perform like modern windows and doors should. They’re made from our proprietary Fibrex® material, which is extremely low maintenance and blocks thermal transfer 700 times better than aluminum to help your customers save money on heating and cooling costs. *Visit andersenwindows.com/warranty for details. **Products with Sandtone, dark bronze and black interiors have matching exteriors. †See your local code official for code requirements in your area. ††100SHS4066 PGUP +50/-50 (AAMA/WDMA/CSA 101/I.S.2/A440-08 & -11). Optional PG50 performance grade upgrade is available for most sizes. For more information, visit andersenwindows.com/100series. “ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. SUPERIOR WEATHER RESISTANCE Our weather-resistant construction seals out drafts, wind and water so well that your reputation is protected whatever the weather. ATTRACTIVE CORNER SEAMS Low-visibility corner seams for a cleaner and more modern look. ATTRACTIVE MATTE INTERIORS Premium matte finish isn’t shiny like vinyl and is available in white, Sandtone, dark bronze and black.** EASY TO OPERATE FOR YEARS TO COME All 100 Series products are tested to the extreme to deliver years* of smooth, reliable operation. PG 50 PERFORMANCE 100SHS4066 PGUP +50/-50 (AAMA/WDMA/CSA 101/I.S.2/A440-08 & -11) OPTIONAL PERFORMANCE UPGRADE †† 3 *Visit andersenwindows.com/warranty for details. **When 100 Series products were tested against five leading competitors’ painted vinyl window products. DURABILITY Think vinyl, only stronger. The proprietary Fibrex® material in our 100 Series products has all the benefits of vinyl while holding up better to weather and wear. This way your customers’ windows and doors are better protected from warping and cracking, even in tough climates.* The finish on 100 Series products has superior scratch resistance compared to painted vinyl windows** so they’ll look beautiful for years to come. Fibrex material retains its stability and rigidity in all climates, delivering exceptional durability. It makes our 100 Series products rigid and strong so the weathertight seals stay weathertight. 100 Series products can withstand temperatures up to 150◦F, even for dark colors, meaning they won’t warp due to sun exposure. THAN PAINTED VINYL THICKERFINISH 12X FIBREX® MATERIAL ** FIBREX® MATERIAL THAN VINYL STRONGER 2X 150WITHSTANDS TEMPERATURES FIBREX® MATERIAL 4 *Visit andersenwindows.com/warranty for details. **When tested against five leading competitors’ painted vinyl window products. REVOLUTIONARY BUILDING MATERIAL • Twice as strong as vinyl so weathertight seals stay weathertight • Blocks thermal transfer nearly 700 times better than aluminum to help reduce heating and cooling bills • Retains its stability and rigidity in all climates for exceptional durability • Offers superior scratch resistance compared to painted vinyl* ENVIRONMENTALLY RESPONSIBLE • Since Andersen developed the highly sustainable Fibrex material, reuse of waste wood fiber has prevented the harvesting of nearly 90 million board feet of timber • 100 Series products can help builders earn LEED® points in three key categories: Energy & Atmosphere, Materials & Resources and Indoor Environmental Quality • 100 Series products meet or exceed California Section 01350 Specification, a California indoor emission standard – one of the toughest in the country • Like all Andersen products, 100 Series products are designed to last** and help reduce future waste streams See how Andersen created Fibrex material at andersenwindows.com/fibrex. FIBREX® MATERIAL Developed by Andersen, Fibrex material is a revolutionary structural composite material that blends the very best attributes of vinyl and wood. Fibrex material saves on natural resources because it’s composed of 40% reclaimed wood fiber by weight. Special polymer formulations surround and fill each wood fiber, enabling top performance. The result is a material that provides uncommon value and enhances the quality of any project. In use for over two decades in Andersen® products, Fibrex material has proven its strength and durability in all types of climates. 5 400,000 Av e r a g e M o d u l u s Fibrex® Material Vinyl Pine 385,800 STABLE & PREDICTABLE Fibrex ® material is twice as stiff as vinyl. This strength makes it a better choice over time. DURABLE & RELIABLE All materials expand and contract when exposed to extreme temperatures. In these types of conditions, Fibrex material performs twice as well as vinyl, which can bow and crack over time. EXCELLENT INSULATOR The built-in thermal qualities of Fibrex material mean that less heat and cold get transferred through the product into your customers’ homes. As an insulator, it’s on par with vinyl and far superior to aluminum. MOISTURE RESISTANT Because Fibrex material combines wood fiber and a special polymer formula, water has a tough time penetrating. The result is an increased resistance to rot. Thermal Expansion Fibrex® Material 1.0 3.0 2.0 4.0 0 Vinyl Pine Aluminum 1.57 3.42 1.18.25In / I n ° F x 1 0 -5 Thermal Conductivity Fibrex® Material 0.3 0.9 0.6 1.2 0 Vinyl Pine Aluminum .13 .10 .07 BT U / h r . f t . ° F Decay of Materials Fibrex® Material 10 30 20 40 50 0 Vinyl Treated Pine Untreated Pine 0%10%0% 50% % W e i g h t L o s s D u e t o D e c a y HEAT RESISTANT Fibrex material can withstand temperatures in excess of 150°F, even for dark colors, making it a great fit for your projects in hot climates. 800,000 1,200,000 Stiffness 807,600 1,213,000 92.00 6 WINDOW & DOOR TYPES Available in custom sizes to fit all projects. GLIDING WINDOWS Gliding windows have one stationary sash and one operating sash that glides horizontally. A three-sash configuration, where two sash glide past a fixed center sash, is also available. CASEMENT & AWNING WINDOWS Casement windows are hinged on the side and open outward to the left or right, while awning windows are hinged at the top and open outward. Both are also available as non-operating stationary windows. SINGLE-HUNG WINDOWS Single-hung windows feature a fixed upper sash with an operable lower sash that slides up and down. For convenience, the hardware locks automatically when the window is closed. An arch single-hung is also available to add architectural interest. Picture With Flanking Casements Twin Casement Gliding Stationary-Active Gliding Active-Stationary Gliding Active-Stationary-Active, 1:1:1 Sash Ratio Gliding Active-Stationary-Active, 1:2:1 Sash Ratio Arch Single-HungTwin Single-Hung Picture With Flanking Single-Hungs 7 GLIDING PATIO DOORS Patio doors feature one stationary panel and one operating panel that glides smoothly on adjustable rollers. They feature a multi-point locking system for enhanced security and an optional exterior keyed lock for convenience. Sidelights and transoms are also available. PICTURE, TRANSOM & SPECIALTY WINDOWS Choose from a variety of shapes to make a signature statement or provide a delicate lighting accent. Shapes include picture, transom, half circle, quarter circle, circle, Springline™ and arch windows. Custom shapes are also available, including unequal leg arch, trapezoid, pentagon, octagon and triangle windows. 8 • 3 1/8" (79) uniform sight lines allow for easy specification • An extension jamb attachment flange is available for easy application of extension jambs on the job site • Single-hung drywall pass-through windows have an upper sash that can be easily removed on the job site after the window is installed.* With both sash removed, drywall can easily fit through upper-floor windows. Single-Hung Gliding Casement 3 1/8" (79) WINDOW FRAME OPTIONS You’ll find a 100 Series window to match any project from commercial to residential, no matter the location. And with uniform sight lines, it’s easy to specify 100 Series products for the entire project. Additionally, 100 Series window frame options offer the flexibility needed to complete everything from new construction to home improvement, and they’re available in 1/8" (3) increments when custom sizing is required. 1-3/8" Flange Setback 1" Flange Setback 1 3/8" (35) 1-3/8" Flange Setback 1" Flange Setback Stucco Key 1" (25) *Optional drywall pass-through window is not available with flush fin frame. Dimensions in parentheses are in millimeters. NEW CONSTRUCTION WINDOW FRAME OPTIONS 1 3/8 " (35) Flange Setback • Designed for new construction • Integral installation flange makes installation into a new opening easy and helps make sure the windows and doors are weathertight 1" (25) Flange Setback With Stucco Key • For new construction with stucco exteriors • Stucco key eliminates gaps that can result from the natural contraction of the exterior stucco • Integral installation flange makes installation into a new opening easy and helps make sure the windows and doors are weathertight 9 Flush Fin Frame • Allows for easy replacement in stucco applications when installing over an existing aluminum window frame • Minimizes disruption to the home’s stucco exterior • Flush fin has grooves at 1/2" (13) and 1" (25) for easy trimming • Flat and curved interior trim is available to cover the existing window frame • Available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Dimensions in parentheses are in millimeters. Insert1-3/8" Flange Setback NO Flange1" Flange Setback No Flange Frame • Allows for full removal of an existing window when the existing frame is rotten or damaged • Installed into the existing rough opening • Includes pre-drilled, through-the-jamb installation holes and installation screws to save you time No Installation Flange Insert1-3/8" Flange Setback NO Flange1" Flange Setback Flush Fin Sill Extender Accessory Kerf Insert Frame • Provides fast and easy window replacement when installing into an existing window frame • Saves time and money with minimal disruption to the interior or exterior trim • Exterior accessory kerf for convenient finishing of the window • Installation accessories include an exterior sill extender to fill the gap at the sill (shown) in addition to exterior frame extender for sides and a head expander REPLACEMENT WINDOW FRAME OPTIONS 10 *Products with Sandtone, dark bronze and black interiors have matching exteriors. Printing limitations prevent exact duplication of colors. See your Andersen supplier for actual color samples. Dark Bronze *Dark Bronze* Black *Black* TerratoneSandtone *Sandtone* White White EXTERIOR COLORS INTERIOR COLORS EXTERIORS & INTERIORS 100 Series windows and patio doors come in five exterior colors, including dark bronze and black – colors that are darker and richer than those of most vinyl windows. The interiors feature a premium matte finish for an attractive appearance. 11 *Available for exterior handle only. Printing limitation prevent exact replication of colors and finishes. See your Andersen supplier for actual color and finish samples. Dark BronzeBlack Sandtone White Antique Brass Bright BrassBlack Satin Nickel White Antique Brass Dark BronzeBlack Casement & Awning Windows Folding handles avoid interference with window treatments. Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Single-Hung & Gliding Windows Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Hardware color matches the window’s interior. Shown in white. Lock automatically engages when window is closed. Standard Lock Optional Lift/Pull Optional Metal Slim Line Lock Lock automatically engages when window is closed. Exterior handle color matches the door’s exterior. Interior handle color matches the door’s interior. Exterior handle shown in dark bronze. Interior handle shown in white. Optional auxiliary foot lock is available. See page 100.Exterior Interior Exterior TULSA Interior Standard Handle Bold name denotes color or finish shown. Gliding Patio Doors HARDWARE WINDOW HARDWARE FINISHES TULSA HARDWARE FINISHES AFTON Optional Handle Antique Brass Black Bright Brass Satin Nickel Optional auxiliary foot lock is available. See page 100. Bold name denotes color or finish shown. AFTON HARDWARE FINISHES Satin Nickel Sandtone †Terratone* 12 ANDERSEN, STRONG INCREDIBLY UNIQUELY 100 SERIES 13 “ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. Center of glass performance only. Ratings based on glass options as of August 2023. Visit andersenwindows.com/energystar for ENERGY STAR map and NFRC total unit performance data. Stainless Steel GLASS Andersen has the glass you need to get the performance you want, with options for every climate, project and customer. Check with your supplier for the selections that meet ENERGY STAR® requirements in your area. For more details on our glass options, visit andersenwindows.com/glass. HEATLOCK TECHNOLOGY Applied to the room-side glass surface, HeatLock coating reflects heat back into the home for improved performance. ADDITIONAL GLASS OPTIONS Tempered safety glass is standard on patio doors and required for larger window sizes. Patterned glass lets in light while obscuring vision and adds a unique, decorative touch. TIME-SAVING FILM We protect our products during delivery and construction with translucent film on the glass that peels away for a virtually spotless window. Cascade ObscureFern Reed Satin Etch Black GLASS SPACER OPTIONS In addition to stainless steel glass spacers, black glass spacers are available as another way to customize project designs and achieve a contemporary style. Black glass spacers can blend in with the color of the window or door for a sleek design or serve as a shadow line. Add full divided light grilles and the grille spacer bar between the glass will match. Cascade and Reed patterns are only available in a vertical orientation. ENERGY LIGHT How well a product blocks heat caused by sunlight. Visible Light Transmittance How much visible light comes through a product. UV Protection How well a product blocks ultraviolet rays.GLASS How well a product prevents heat from escaping. Solar Heat Gain CoefficientU-Factor lmmm llmm lmmm llmm lllm llll lmmm lllm lllm lllm lllm lllm lmmm mmmm llll mmmmHigh visibility, with basic thermal performance. Ideal for northern, passive solar construction applications where solar heat gain is desired. Applied to the room-side surface, it reflects heat back into the home and improves U-Factor values. Outstanding thermal control in southern climates where less solar heat gain is desired. Applied to the room-side surface, it reflects heat back into the home and improves U-Factor values. PassiveSun with HeatLock Coating Clear Dual-Pane PassiveSun® Sun lllm llll llll lllm llll llmm llmm llll Applied to the room-side surface, it reflects heat back into the home and improves U-Factor values. Thermal control similar to tinted glass, with visible light transmittance similar to Low-E glass. SmartSun with HeatLock® Coating SmartSun™ Low-E with HeatLock Coating Low-E Outstanding overall performance for climates where both heating and cooling costs are a concern. lllm lllm lllm lllm lllm lllm lllm lllm Triple-pane glass is now available for most casement, awning, picture & transom windows. Click for more information. 14 *Specify number of same-size rectangles across or down. Dimensions in parentheses are in millimeters. GRILLES Grilles for 100 Series windows and patio doors are available in a wide variety of patterns to complement virtually any style of home. Plus, they have options for easy cleaning and architectural authenticity many vinyl windows can’t match. FULL DIVIDED LIGHT Permanently applied to the exterior and interior of the window, with a spacer between the glass. SIMULATED DIVIDED LIGHT Permanently applied to the exterior and interior of the window, without a spacer between the glass. FINELIGHT™ GRILLES-BETWEEN-THE-GLASS Make glass easy to clean and have an elegant, sculpted profile. Choose a two-sided color scheme to match both the interior and exterior of the window or patio door. Also available with exterior grilles to provide architectural style and detail. Permanent exterior and permanent interior with spacer Permanent exterior and permanent interior without spacer Finelight grilles- between-the-glass Finelight grilles- between-the-glass with permanent exterior To see all of the standard patterns available for a specific window or door, refer to the detailed product sections in this product guide or contact your Andersen supplier. Prairie A Colonial Short Fractional Tall Fractional Specified **Equal Light* Grille Patterns Custom Grille Bar Widths A 2 1/4" (57) width grille is available for most units to simulate a meeting rail or a multi-unit combination such as a transom over a window or patio door. 3/4" (19) width grille bar for windows. 1" (25) width grille bar for patio doors. 1” Doors 3/4” Windows 2 1/4” Full Divided Light Grille Simulated Check Rail Casement Only 2 1/4” Simulated Divided Light Simulated Check Rail Casement Only 2 1/4” Simulated Check Rail 1” Doors 3/4” Windows 2 1/4” Full Divided Light Grille Simulated Check Rail Casement Only 2 1/4” Simulated Divided Light Simulated Check Rail Casement Only 2 1/4” Simulated Check Rail Actual width shown. 1” Doors 3/4” Windows 2 1/4” Full Divided Light Grille Simulated Check Rail Casement Only 2 1/4” Simulated Divided Light Simulated Check Rail Casement Only 2 1/4” Simulated Check Rail INSECT SCREENS Insect screens for venting windows have a fiberglass screen mesh. Optional TruScene® insect screens are made with a micro-fine stainless steel mesh, providing more than 50% greater clarity than our conventional insect screens. Insect screen frames for casement and awning windows are color matched to the product interior and for single-hung and gliding windows are matched to the product exterior. Gliding insect screens for two-panel gliding patio doors have a fiberglass screen mesh. Insect screen frames for doors are color matched to the product exterior. Colonial Modified Colonial Prarie A Tall Fractional Specified Equal Light Simulated Single-Hung Short FractionalColonial Modified Colonial Prarie A Tall Fractional Specified Equal Light 2x2Simulated Single-Hung Specified Equal Light 2x4Short Fractional Victorian RenaissanceColonial Modified Colonial Prarie A Tall Fractional Specified Equal Light 2x2Simulated Single-Hung Specified Equal Light 2x4Short Fractional Victorian Renaissance Renaissa Modified Colonial Colonial Modified Colonial Prarie A Tall Fractional Specified Equal Light 2x2Simulated Single-Hung Specified Equal Light 2x4Short Fractional Victorian RenaissanceColonial Modified Colonial Prarie A Tall Fractional Specified Equal Light 2x2Simulated Single-Hung Specified Equal Light 2x4Short Fractional Victorian Renaissance Renaissance and Su Colonial Modified Colonial Prarie A Tall Fractional Specified Equal Light 2x2Simulated Single-Hung Specified Equal Lig Short Fractional 15 *2022 Andersen brand survey of U.S. builders. OF ANDERSEN’S MATERIAL OUTPERFORM VINYL WINDOWS* FIBREX® COMPOSITE WINDOWS MADE BUILDERS AGREE 16 Dimensions in parentheses are in millimeters. Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. AN EASIER WAY TO BUILD BIGGER VIEWS Now available for joining patio doors in addition to windows, our unique reinforced fiberglass joining system makes it easier for you to design and install large combinations in your projects. The Easy Connect Joining System uses strong fiberglass construction – for windows, choose from three options: fully assembled factory-joined combinations, partially assembled factory-prepped combinations or field join kits; patio doors use field join kits. For windows, non-reinforced joining options include factory-joined combinations or field join kits. For more information, visit andersenwindows.com/joining.Innovative patented reinforced joining system utilizes 5 1/8" (130) interlocking fiberglass joining plates. Window joining shown. 1 2 3 4 A B C D E F G H 1 2 3 4 A B C D E F G H 1 2 3 4 1 2 A B E F 3 4 C D G H 1 2 3 4 Reinforced Factory-Prepped Window Combinations Receive lighter, easier-to-handle, pre-assembled smaller window combinations that join as you install them into the rough opening, making it easier to install large combinations. In fact, most contractors surveyed said they could reduce the number of installers by 50% using the Andersen® Easy Connect Joining System.* A 1 E B 2 F C 3 G D 4 H 1 2 3 4 A B C D E F G H 1 2 3 4 A B C D E F G H 1 2 3 4 1 2 A B E F 3 4 C D G H 1 2 3 4 Reinforced Factory-Joined Window Combinations Eliminate the need for job site assembly and receive fully assembled, factory-joined window combinations to fit rough openings up to 12' (3658) x 8' (2438) or 8' (2438) x 12' (3658). Appearance of a reinforced join. Appearance of a non-reinforced join. ASSEMBLY READY TO INSTALL NUMBER OF INSTALLERS* HALLMARK CERTIFIED** TESTED TO AAMA 450 PERFORMANCE COMBINATION SIZE LIMITATIONS REINFORCED FACTORY-JOINED WINDOW COMBINATIONS FACTORY l MORE l l Extensive unit combination size options available certified to PG50** Maximum join length: 12' Maximum combination: 12' x 8' or 8' x 12' 96 sq. ft. or 8.92 m2 REINFORCED FACTORY-PREPPED WINDOW COMBINATIONS IN THE OPENING l FEWER l l Extensive unit combination size options available certified to PG50** Maximum join length: 12' Maximum combination height: 16'' No maximum width REINFORCED FIELD JOIN KITS JOB SITE MORE l l Extensive unit combination size options available certified to PG50** Maximum join length: 12' Maximum combination: 16' x 9' or 12' x 12' 144 sq. ft. or 13.34 m2 NON-REINFORCED FACTORY-JOINED WINDOW COMBINATIONS FACTORY l MORE l l Extensive unit combination size options available certified up to PG50** Maximum join length: 8' Maximum combination: 12' x 8' or 8' x 12' 96 sq. ft. or 8.92 m2 NON-REINFORCED FIELD JOIN KITS JOB SITE MORE l l Extensive unit combination size options available certified up to PG50** Maximum join length: 8' Maximum combination: 12' x 8' or 8' x 12' 96 sq. ft. or 8.92 m2 Reinforced & Non-Reinforced Window Interiors *69% of 156 builders/general contractors in a 2018 survey said they could reduce the number of installers by half using the Easy Connect Joining System when comparing the installation of a 12' (3658) wide x 8' (2438) high pre-assembled window combination unit with four 3' (914) wide x 8' (2438) high window combination units. **Easy Connect and other fiberglass joins are certified up to PG50 when installed according to Andersen installation instructions. Dimensions in parentheses are in millimeters. Casement Tables of Sizes .................................... 20-22 Specifications ....................................... 23-24 Grille Patterns ............................................. 24 Window Details .................................. 25-26 Awning Tables of Sizes ..................................... 27-28 Specifications ............................................. 29 Grille Patterns ............................................. 28 Window Details .................................. 30-31 Single-Hung Tables of Sizes ....................... 32-40, 42-49 Specifications ......... 33, 35, 41, 43, 45, 47 Grille Patterns ............................................. 49 Window Details .................................. 50-54 Gliding Tables of Sizes .................................... 55-59 Specifications ...................................... 60-65 Grille Patterns ............................................. 65 Window Details .................................. 66-67 Picture, Transom & Specialty Tables of Sizes ....................... 68-75, 78-81 Specifications ............................... 70-73, 82 Custom Shapes ....................................76-77 Grille Patterns ............................................. 79 Window Details .................................. 83-86 Joining Details ........................................... 88-93 Custom Sizes ............................................ 94-98 Combination Designs ................................... 107 Product Performance ..................................... 111 WINDOWS in 1⁄8" (3) increments CUSTOM SIZING 100 SERIES *Visit andersenwindows.com/warranty for details. **Available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. †Products with Sandtone, dark bronze and black interiors have matching exteriors. Printing limitations prevent exact duplication of colors. See your Andersen supplier for actual color samples. Dimensions in parentheses are in millimeters. Black† Dark **Bronze† Sandtone†White INTERIOR COLORS Sandtone Terratone FEATURES CASEMENT & AWNING SINGLE-HUNG COMMON FEATURES Dark Bronze EXTERIORS & INTERIORS White Black EXTERIOR COLORS A B C D A B D E F G H Equal Sash Arch Single-Hung Reverse Cottage Sash Single-Hung E FFRAME A Constructed with Fibrex® composite material. This construction produces a rigid frame. The durable, low-maintenance finish won’t fade, flake, blister or peel.* Concealed receiving brackets mounted on the hinge side of the frame keep the sash tightly secured within the window frame when closed. B See Common Features for frame options. SASH C Fibrex material construction provides long-lasting performance.* The sash, finished with a durable capping, provides maximum protection and a low-maintenance matte finish. D The dual weatherstrip system combines both an exterior watershed design and a bulb weatherstrip seal between the sash and frame. The result is a long-lasting,* energy-efficient barrier against wind, water and dust. GLASS E A glazing bead and silicone provide superior weathertightness and durability. F See Common Features for glass options. HARDWARE Sash operator provides easy to operate opening and closing, regardless of window size. Long-lasting stainless steel hinge channels are used at the head and sill to provide easy operation. Single-Action Casement Sash Lock A single-action lock easily releases all concealed locking points on the casement sash. The color or finish of the lock hardware matches the handle. Awning Sash Locks Awning sash locks provide an added measure of security and weathertightness. The standard sash lock matches the window’s interior color. C FRAME A Constructed with Fibrex® composite material. This construction produces a rigid frame. The durable, low-maintenance finish won’t fade, flake, blister or peel.* B A durable side-loaded balancer provides for easy sash opening and closing. The lower sash can be removed without the use of tools. C Weep holes are located on the exterior nose of the sill for proper water management. D See Common Features for frame options. SASH The lower sash has a meeting rail cover with a unique raised profile design, allowing the sash to be opened and closed easily. E Fibrex material construction provides long-lasting performance.* The sash, finished with a durable capping, provides maximum protection and a matte low-maintenance finish. F Dual felt weatherstrip provides a long-lasting,* energy-efficient barrier against wind, water and dust. GLASS G A glazing bead and silicone provide superior weathertightness and durability. H See Common Features for glass options. HARDWARE Sash Lock The sash lock engages automatically when the lower sash is closed. The standard sash lock matches the window’s interior color. SHAPES & SASH OPTIONS 18 WINDOWS FRAME Five frame options include: • 1 3 ⁄8" (35) flange setback for new construction siding applications. • 1" (25) flange setback with stucco key for new construction stucco applications. • No flange for full removal and replacement of an existing window when the existing frame is rotten or damaged. • Insert for window replacement into an existing window frame. • Flush fin** for stucco applications when installing over an existing aluminum window frame. For frame drawings and more detailed information, see pages 8-9. GLASS Glass spacers are available in stainless steel and black. High-Performance options include: • Low-E SmartSun™ glass • Low-E SmartSun HeatLock® glass • Low-E glass • Low-E HeatLock glass • Low-E Sun glass • Low-E PassiveSun® glass • Low-E PassiveSun HeatLock glass • Clear dual-pane glass Tempered glass, STC glass and other glass options are available. Contact your Andersen supplier. A removable translucent film helps shield the glass from damage during delivery and construction, and simplifies finishing at the job site. Patterned Glass Patterned glass options are available. See page 13 for more details. PERFORMANCE OPTIONS Performance Grade (PG) Upgrades PG upgrades are available for select sizes of standard non-impact windows, allowing units to achieve PG50. PG ratings are more comprehensive than Design Pressure (DP) ratings for measuring product performance. Choosing the PG50 upgrade doesn’t change the appearance of the unit. For up-to-date performance ratings, visit andersenwindows.com. Triple-pane glass is now available for most casement, awning, picture & transom windows. Click for more information. Dimensions in parentheses are in millimeters. Printing limitations prevent exact replication of colors and finishes. See your Andersen supplier for actual color and finish samples. *Visit andersenwindows.com/warranty for details. **TruScene insect screens let in over 25% more fresh air than standard Andersen fiberglass insect screens. SandtoneAntique Brass Dark Bronze Black Satin Nickel White GLIDING HARDWARE PICTURE, TRANSOM & SPECIALTY ACCESSORIES Sold Separately Single-Hung & Gliding Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Casement & Awning Standard Lock Optional Lift/Pull Hardware color matches the window’s interior. Shown in white. Bold name denotes color or finish shown. Antique Brass Black Dark Bronze Sandtone Satin Nickel White Folding handles avoid interference with window treatments. HARDWARE FINISHES HARDWARE Window Opening Control Device A window opening control device is available for casement, single-hung and gliding windows, which limits sash travel to less than 4" (102) when the window is first opened. Available factory applied, or as a field-applied kit in stone, white and black. Vent Limiter for Awning Windows A vent limiter is available for awning windows, which prevents opening the sash more than 4" (102). Available factory applied or as a field-applied kit. GRILLES Grilles are available in a variety of configurations. See page 14 for details. INSECT SCREENS Conventional Insect Screens Insect screens have charcoal gray fiberglass screen mesh. For casement and awning windows, frames are color matched to the product interior. For single-hung and gliding windows, stainless steel springs hold the insect screen tightly to the window frame, and their frames are available in colors to match the product’s exterior. TruScene® Insect Screens Our TruScene insect screens let in over 25% more fresh air** and provide 50% greater clarity than conventional Andersen insect screens, all while keeping out unwanted small insects. For casement and awning windows, the frame color matches the product interior. For single-hung and gliding windows, the frame color matches the product’s exterior. A C D E F G B A B C D Optional Metal Slim Line Lock FRAME A Constructed with Fibrex® composite material. This construction produces a rigid frame. The durable, low-maintenance finish won’t fade, flake, blister or peel.* B See Common Features for frame options. SASH The operating sash has a meeting stile cover with a unique raised profile design, allowing the sash to be opened and closed easily. C Fibrex material construction provides long-lasting performance.* The sash, finished with a durable capping, provides maximum protection and a matte low-maintenance finish. D Dual felt weatherstrip provides a long-lasting,* energy-efficient barrier against wind, water and dust. E Operating sash has four metal rollers mounted at the bottom for easy, smooth travel over the sill. GLASS F A glazing bead and silicone provide superior weathertightness and durability. G See Common Features for glass options. HARDWARE Sash Lock The sash lock engages automatically when the operable sash is closed. The standard sash lock matches the window’s interior color. FRAME A Constructed with Fibrex® composite material. This construction produces a rigid frame. The durable, low-maintenance finish won’t fade, flake, blister or peel.* B See Common Features for frame options. GLASS C A glazing bead and silicone provide superior weathertightness and durability. D See Common Features for glass options. SHAPES Along with rectangular windows, half circle, quarter circle, circle, Springline™ and arch windows are available in both standard and custom sizes. Custom windows are also available in unequal leg arch, trapezoid, pentagon, octagon and triangle shapes. 19 10 0 S e r i e s W i n d o w Ov e r v i e w 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610) with appropriate hinge specified. See table on page 23. Choose left, right or stationary as viewed from the exterior. Grille patterns shown on page 24. Details shown on pages 25-26. Custom-size windows are available in 1 ⁄8" (3) increments. See page 94 for custom sizes and specifications. 2620 302016202020 2626 302616262026 2630 303016302030 2636 303616362036 2640 304016402040 2646 304616462046 2650 30501650 2050 2656 305616562056 2660 30601660 2060 Window Dimension Unobstructed Glass Minimum Rough Opening Table of Casement Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 CU S T O M H E I G H T S — 23 1 ⁄ 2" t o 71 1 ⁄ 2" CUSTOM WIDTHS — 17 1 ⁄2" to 35 1 ⁄2" 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 11 1/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 17 1/4" 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 1' - 1 1 1/2" (749) (762) (591) (902) (914) (743) (445) (457) (286) (597) (610) (438) (59 7 ) (61 0 ) (43 8 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (89 5 )Left Right StationaryLeftRightStationary 20 CASEMENT & AWNING WINDOWS Custom-size windows are available in 1 ⁄8" (3) increments. See page 94 for custom sizes and specifications. Choose left, right or stationary as viewed from the exterior. In addition to venting shown, other standard configurations are available. Windows have one continuous outer frame. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 24. Details shown on pages 25-26. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610) with appropriate hinge specified. See table on pages 23-24. 2020-21620-2 1920-2 2026-21626-2 1926-2 2030-21630-2 1930-2 2036-21636-2 1936-2 2040-21640-2 1940-2 2046-21646-2 1946-2 2050-21650-2 1950-2 2056-21656-2 1956-2 2060-2 2320-2 2620-2 2920-2 2326-2 2626-2 2926-2 2330-2 2630-2 2930-2 2336-2 2636-2 2936-2 2340-2 2640-2 2940-2 2346-2 2646-2 2946-2 2350-2 2650-2 2950-2 2356-2 2656-2 2956-2 2360-2 2660-2 2960-21660-2 1960-2 2010-2 2310-2 2610-2 2910-21610-2 1910-2 2016-2 2316-2 2616-2 2916-21916-2 2020-2 2320-2 2620-2 2920-21620-2 1920-2 3020-2 3026-2 3030-2 3036-2 3040-2 3046-2 3050-2 3056-2 3060-2 3010-2 3016-2 3020-2 1616-2 Window Dimension Unobstructed Glass (width of single sash) Minimum Rough Opening Table of Twin Casement Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 CUSTOM WIDTHS — 35 1 ⁄2" to 71 1 ⁄2" CU S T O M H E I G H T S — 23 1 ⁄2" t o 71 1 ⁄2" 11 1/4" 2'-11 1/2" 3'-0" 17 1/4" 3'-11 1/2" 4'-0" 14 1/4" 3'-5 1/2" 3'-6" 4'-5 1/2" 4'-6" 20 1/4"23 1/4" 4'-11 1/2" 5'-0" 26 1/4" 5'-5 1/2" 5'-6"6'-0" 5'-11 1/2" 29 1/4" 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 17 1/4" 1' - 1 1 1/2" 2' - 0 " 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " (902) (914) (286) (1207) (1219) (438) (1054) (1067) (362) (1359) (1372) (514) (1511) (1524) (591) (1664) (1676) (667) (1816) (1829) (743) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (59 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (89 5 ) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) 21 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610) with appropriate hinge specified. See table on pages 23-24. Choose left, right or stationary as viewed from the exterior. In addition to venting shown, other standard configurations are available. Windows have one continuous outer frame. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 24. Details shown on pages 25-26. 26-5020-2616-3020-16 20-4020-20 26-5026-2616-3026-16 20-4026-20 26-5030-2616-3030-16 20-4030-20 26-5036-2616-3036-16 20-4036-20 26-5040-2616-3040-16 20-4040-20 26-5046-2616-3046-16 20-4046-20 26-5050-2616-3050-16 20-4050-20 26-5056-2616-3056-16 20-4056-20 26-5060-26 30-6020-30 30-6026-30 30-6030-30 30-6036-30 30-6040-30 30-6046-30 30-6050-30 30-6056-30 30-6060-3016-3060-16 20-4060-20 26-5010-26 30-6010-3016-3010-16 20-4010-20 26-5016-26 30-6016-3016-3016-16 20-4016-20 26-5020-26 30-6020-3016-3020-16 20-4020-20 Window Dimension Minimum Rough Opening Table of Picture Window With Flanking Casements Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 Unobstructed Glass (width of center sash) 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 17 1/4" 1' - 1 1 1/2" 2' - 0 " 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 6'-0" 5'-11 1/2" 29 1/4"41 1/4" 7'-11 1/2" 8'-0" 65 1/4" 11'-11 1/2" 12'-0" 53 1/4" 9'-11 1/2" 10'-0" 17 1/4"Unobstructed Glass (width of single anking sash) 11 1/4"23 1/4"29 1/4" (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (59 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (89 5 ) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (1816) (1829) (743) (2426) (2438) (1048) (3645) (3658) (1657) (3035) (3048) (1353) (438)(286)(591)(743) 22 CASEMENT & AWNING WINDOWS Casement Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Default Hinge Type*Width Inches/(mm) Height Inches/(mm) 1620 0.67 (0.06) 5 3/8" (137) 17 13/16" (452) 1.35 (0.13) 1.46 (0.14) 61 9/16" (1564) 2.86 (0.27) wash mode 1626 0.89 (0.08) 5 3/8" (137) 23 13/16" (605) 1.82 (0.17) 1.95 (0.18) 55 9/16" (1411) 3.59 (0.33) wash mode 1630 1.12 (0.10) 5 3/8" (137) 29 13/16" (757) 2.29 (0.21) 2.44 (0.23) 49 9/16" (1259) 4.31 (0.40) wash mode 1636 1.34 (0.12) 5 3/8" (137) 35 13/16" (909) 2.75 (0.26) 2.94 (0.27) 43 9/16" (1106) 5.04 (0.47) wash mode 1640 1.57 (0.15) 5 3/8" (137) 41 13/16" (1062) 3.22 (0.30) 3.43 (0.32) 37 9/16" (954) 5.77 (0.54) wash mode 1646 1.79 (0.17) 5 3/8" (137) 47 13/16" (1214) 3.69 (0.34) 3.92 (0.36) 31 9/16" (802) 6.50 (0.60) wash mode 1650 2.02 (0.19) 5 3/8" (137) 53 13/16" (1367) 4.16 (0.39) 4.41 (0.41) 25 9/16" (649) 7.23 (0.67) wash mode 1656 2.24 (0.21) 5 3/8" (137) 59 13/16" (1519) 4.63 (0.43) 4.90 (0.46) 19 9/16" (497) 7.96 (0.74) wash mode 1660 2.47 (0.23) 5 3/8" (137) 65 13/16" (1671) 5.10 (0.47) 5.40 (0.50) 13 9/16" (344) 8.69 (0.81) wash mode 2020 1.41 (0.13) 11 3/8" (289) 17 13/16" (452) 2.07 (0.19) 2.20 (0.20) 61 9/16" (1564) 3.84 (0.36) wash mode 2026 1.88 (0.18) 11 3/8" (289) 23 13/16" (605) 2.79 (0.26) 2.94 (0.27) 55 9/16" (1411) 4.81 (0.45) wash mode 2030 2.36 (0.22) 11 3/8" (289) 29 13/16" (757) 3.50 (0.33) 3.69 (0.34) 49 9/16" (1259) 5.79 (0.54) wash mode 2036 2.83 (0.26) 11 3/8" (289) 35 13/16" (909) 4.22 (0.39) 4.43 (0.41) 43 9/16" (1106) 6.77 (0.63) wash mode 2040 3.31 (0.31) 11 3/8" (289) 41 13/16" (1062) 4.94 (0.46) 5.17 (0.48) 37 9/16" (954) 7.75 (0.72) wash mode 2046 3.78 (0.35) 11 3/8" (289) 47 13/16" (1214) 5.66 (0.53) 5.91 (0.55) 31 9/16" (802) 8.73 (0.81) wash mode 2050 4.26 (0.40) 11 3/8" (289) 53 13/16" (1367) 6.38 (0.59) 6.65 (0.62) 25 9/16" (649) 9.71 (0.90) wash mode 2056 4.73 (0.44) 11 3/8" (289) 59 13/16" (1519) 7.10 (0.66) 7.40 (0.69) 19 9/16" (497) 10.69 (0.99) wash mode 2060 5.21 (0.48) 11 3/8" (289) 65 13/16" (1671) 7.82 (0.73) 8.14 (0.76) 13 9/16" (344) 11.67 (1.08) wash mode 2620 2.15 (0.20) 17 3/8" (442) 17 13/16" (452) 2.79 (0.26) 2.94 (0.27) 61 9/16" (1564) 4.81 (0.45) wash mode 2626 2.88 (0.27) 17 3/8" (442) 23 13/16" (605) 3.75 (0.35) 3.94 (0.37) 55 9/16" (1411) 6.04 (0.56) wash mode 2630 3.60 (0.33) 17 3/8" (442) 29 13/16" (757) 4.72 (0.44) 4.93 (0.46) 49 9/16" (1259) 7.27 (0.68) wash mode 2636 4.33 (0.40) 17 3/8" (442) 35 13/16" (909) 5.69 (0.53) 5.92 (0.55) 43 9/16" (1106) 8.50 (0.79) wash mode 2640 ◊6.30 (0.59) 21 11/16" (551) 41 13/16" (1062) 6.66 (0.62) 6.91 (0.64) 37 9/16" (954) 9.73 (0.90) widest clear opening 2646 ◊7.21 (0.67) 21 11/16" (551) 47 13/16" (1214) 7.63 (0.71) 7.90 (0.73) 31 9/16" (802) 10.96 (1.02) widest clear opening 2650 ◊8.11 (0.75) 21 11/16" (551) 53 13/16" (1367) 8.60 (0.80) 8.90 (0.83) 25 9/16" (649) 12.19 (1.13) widest clear opening 2656 ◊9.02 (0.84) 21 11/16" (551) 59 13/16" (1519) 9.57 (0.89) 9.89 (0.92) 19 9/16" (497) 13.42 (1.25) widest clear opening 2660 ◊9.92 (0.92) 21 11/16" (551) 65 13/16" (1671) 10.54 (0.98) 10.88 (1.01) 13 9/16" (344) 14.65 (1.36) widest clear opening 3020 2.89 (0.27) 23 3/8" (594) 17 13/16" (452) 3.50 (0.33) 3.69 (0.34) 61 9/16" (1564) 5.79 (0.54) wash mode 3026 3.87 (0.36) 23 3/8" (594) 23 13/16" (605) 4.72 (0.44) 4.93 (0.46) 55 9/16" (1411) 7.27 (0.68) wash mode 3030 4.84 (0.45) 23 3/8" (594) 29 13/16" (757) 5.94 (0.55) 6.17 (0.57) 49 9/16" (1259) 8.75 (0.81) wash mode 3036 ◊5.82 (0.54) 23 3/8" (594) 35 13/16" (909) 7.16 (0.67) 7.41 (0.69) 43 9/16" (1106) 10.23 (0.95) wash mode 3040 ◊6.79 (0.63) 23 3/8" (594) 41 13/16" (1062) 8.38 (0.78) 8.65 (0.80) 37 9/16" (954) 11.71 (1.09) wash mode 3046 ◊7.77 (0.72) 23 3/8" (594) 47 13/16" (1214) 9.60 (0.89) 9.90 (0.92) 31 9/16" (802) 13.19 (1.23) wash mode 3050 ◊8.74 (0.81) 23 3/8" (594) 53 13/16" (1367) 10.82 (1.00) 11.14 (1.03) 25 9/16" (649) 14.67 (1.36) wash mode 3056 ◊9.72 (0.90) 23 3/8" (594) 59 13/16" (1519) 12.04 (1.12) 12.38 (1.15) 19 9/16" (497) 16.15 (1.50) wash mode 3060 ◊10.69 (0.99) 23 3/8" (594) 65 13/16" (1671) 13.25 (1.23) 13.62 (1.27) 13 9/16" (344) 17.63 (1.64) wash mode continued on next page • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. *To calculate alternative hinge type, see page 94. Twin Casement Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Default Hinge Type*Width Inches/(mm) Height Inches/(mm) 1620-2 0.67 (0.06) 5 3/8" (137) 17 13/16" (452) 2.70 (0.25) 2.92 (0.27) 61 9/16" (1564) 5.79 (0.54) wash mode 1626-2 0.89 (0.08) 5 3/8" (137) 23 13/16" (605) 3.63 (0.34) 3.90 (0.36) 55 9/16" (1411) 7.27 (0.68) wash mode 1630-2 1.12 (0.10) 5 3/8" (137) 29 13/16" (757) 4.57 (0.42) 4.89 (0.45) 49 9/16" (1259) 8.75 (0.81) wash mode 1636-2 1.34 (0.12) 5 3/8" (137) 35 13/16" (909) 5.51 (0.51) 5.87 (0.55) 43 9/16" (1106) 10.23 (0.95) wash mode 1640-2 1.57 (0.15) 5 3/8" (137) 41 13/16" (1062) 6.45 (0.60) 6.86 (0.64) 37 9/16" (954) 11.71 (1.09) wash mode 1646-2 1.79 (0.17) 5 3/8" (137) 47 13/16" (1214) 7.38 (0.69) 7.84 (0.73) 31 9/16" (802) 13.19 (1.23) wash mode 1650-2 2.02 (0.19) 5 3/8" (137) 53 13/16" (1367) 8.32 (0.77) 8.82 (0.82) 25 9/16" (649) 14.67 (1.36) wash mode 1656-2 2.24 (0.21) 5 3/8" (137) 59 13/16" (1519) 9.26 (0.86) 9.81 (0.91) 19 9/16" (497) 16.15 (1.50) wash mode 1660-2 2.47 (0.23) 5 3/8" (137) 65 13/16" (1671) 10.20 (0.95) 10.79 (1.00) 13 9/16" (344) 17.63 (1.64) wash mode 1920-2 1.04 (0.10) 8 3/8" (213) 17 13/16" (452) 3.41 (0.32) 3.66 (0.34) 61 9/16" (1564) 6.77 (0.63) wash mode 1926-2 1.39 (0.13) 8 3/8" (213) 23 13/16" (605) 4.60 (0.43) 4.90 (0.45) 55 9/16" (1411) 8.50 (0.79) wash mode 1930-2 1.74 (0.16) 8 3/8" (213) 29 13/16" (757) 5.79 (0.54) 6.13 (0.57) 49 9/16" (1259) 10.23 (0.95) wash mode 1936-2 2.09 (0.19) 8 3/8" (213) 35 13/16" (909) 6.98 (0.65) 7.36 (0.68) 43 9/16" (1106) 11.96 (1.11) wash mode 1940-2 2.44 (0.23) 8 3/8" (213) 41 13/16" (1062) 8.16 (0.76) 8.60 (0.80) 37 9/16" (954) 13.69 (1.27) wash mode 1946-2 2.79 (0.26) 8 3/8" (213) 47 13/16" (1214) 9.35 (0.87) 9.83 (0.91) 31 9/16" (802) 15.42 (1.43) wash mode 1950-2 3.14 (0.29) 8 3/8" (213) 53 13/16" (1367) 10.54 (0.98) 11.06 (1.03) 25 9/16" (649) 17.15 (1.59) wash mode 1956-2 3.49 (0.32) 8 3/8" (213) 59 13/16" (1519) 11.73 (1.09) 12.30 (1.14) 19 9/16" (497) 18.88 (1.75) wash mode 1960-2 3.84 (0.36) 8 3/8" (213) 65 13/16" (1671) 12.91 (1.20) 13.53 (1.26) 13 9/16" (344) 20.61 (1.91) wash mode 2020-2 1.41 (0.13) 11 3/8" (289) 17 13/16" (452) 4.13 (0.38) 4.40 (0.41) 61 9/16" (1564) 7.75 (0.72) wash mode • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). *To calculate alternative hinge type, see page 94. 23 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 100 SERIES Number of lights and overall pattern varies with window size. Patterns may not be available in all configurations or sizes. Specified equal light and custom patterns are also available. For specified equal light, specify number of same-size rectangles across or down. For more grille options, see page 14 or visit andersenwindows.com/grilles. Custom ExampleSpecied Equal Light Examples Twin Casement Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Default Hinge Type*Width Inches/(mm) Height Inches/(mm) 2026-2 1.88 (0.18) 11 3/8" (289) 23 13/16" (605) 5.57 (0.52) 5.89 (0.55) 55 9/16" (1411) 9.73 (0.90) wash mode 2030-2 2.36 (0.22) 11 3/8" (289) 29 13/16" (757) 7.01 (0.65) 7.37 (0.68) 49 9/16" (1259) 11.71 (1.09) wash mode 2036-2 2.83 (0.26) 11 3/8" (289) 35 13/16" (909) 8.45 (0.78) 8.86 (0.82) 43 9/16" (1106) 13.69 (1.27) wash mode 2040-2 3.31 (0.31) 11 3/8" (289) 41 13/16" (1062) 9.88 (0.92) 10.34 (0.96) 37 9/16" (954) 15.67 (1.46) wash mode 2046-2 3.78 (0.35) 11 3/8" (289) 47 13/16" (1214) 11.32 (1.05) 11.82 (1.10) 31 9/16" (802) 17.65 (1.64) wash mode 2050-2 4.26 (0.40) 11 3/8" (289) 53 13/16" (1367) 12.76 (1.19) 13.31 (1.24) 25 9/16" (649) 19.63 (1.82) wash mode 2056-2 4.73 (0.44) 11 3/8" (289) 59 13/16" (1519) 14.20 (1.32) 14.79 (1.37) 19 9/16" (497) 21.61 (2.01) wash mode 2060-2 5.21 (0.48) 11 3/8" (289) 65 13/16" (1671) 15.63 (1.45) 16.27 (1.51) 13 9/16" (344) 23.59 (2.19) wash mode 2320-2 1.78 (0.17) 14 3/8" (366) 17 13/16" (452) 4.85 (0.45) 5.15 (0.48) 61 9/16" (1564) 8.73 (0.81) wash mode 2326-2 2.38 (0.22) 14 3/8" (366) 23 13/16" (605) 6.54 (0.61) 6.88 (0.64) 55 9/16" (1411) 10.96 (1.02) wash mode 2330-2 2.98 (0.28) 14 3/8" (366) 29 13/16" (757) 8.23 (0.76) 8.61 (0.80) 49 9/16" (1259) 13.19 (1.23) wash mode 2336-2 3.58 (0.33) 14 3/8" (366) 35 13/16" (909) 9.91 (0.92) 10.35 (0.96) 43 9/16" (1106) 15.42 (1.43) wash mode 2340-2 4.18 (0.39) 14 3/8" (366) 41 13/16" (1062) 11.60 (1.08) 12.08 (1.12) 37 9/16" (954) 17.65 (1.64) wash mode 2346-2 4.78 (0.44) 14 3/8" (366) 47 13/16" (1214) 13.29 (1.23) 13.81 (1.28) 31 9/16" (802) 19.88 (1.85) wash mode 2350-2 5.38 (0.50) 14 3/8" (366) 53 13/16" (1367) 14.98 (1.39) 15.55 (1.44) 25 9/16" (649) 22.11 (2.05) wash mode 2356-2 5.98 (0.56) 14 3/8" (366) 59 13/16" (1519) 16.66 (1.55) 17.28 (1.61) 19 9/16" (497) 24.34 (2.26) wash mode 2360-2 6.58 (0.61) 14 3/8" (366) 65 13/16" (1671) 18.35 (1.70) 19.02 (1.77) 13 9/16" (344) 26.56 (2.47) wash mode 2620-2 2.15 (0.20) 17 3/8" (442) 17 13/16" (452) 5.57 (0.52) 5.89 (0.55) 61 9/16" (1564) 9.71 (0.90) wash mode 2626-2 2.88 (0.27) 17 3/8" (442) 23 13/16" (605) 7.51 (0.70) 7.87 (0.73) 55 9/16" (1411) 12.19 (1.13) wash mode 2630-2 3.60 (0.33) 17 3/8" (442) 29 13/16" (757) 9.45 (0.88) 9.86 (0.92) 49 9/16" (1259) 14.67 (1.36) wash mode 2636-2 4.33 (0.40) 17 3/8" (442) 35 13/16" (909) 11.38 (1.06) 11.84 (1.10) 43 9/16" (1106) 17.15 (1.59) wash mode 2640-2 ◊6.30 (0.59) 21 11/16" (551) 41 13/16" (1062) 13.32 (1.24) 13.82 (1.28) 37 9/16" (954) 19.63 (1.82) widest clear opening 2646-2 ◊7.21 (0.67) 21 11/16" (551) 47 13/16" (1214) 15.26 (1.42) 15.81 (1.47) 31 9/16" (802) 22.11 (2.05) widest clear opening 2650-2 ◊8.11 (0.75) 21 11/16" (551) 53 13/16" (1367) 17.20 (1.60) 17.79 (1.65) 25 9/16" (649) 24.59 (2.28) widest clear opening 2656-2 ◊9.02 (0.84) 21 11/16" (551) 59 13/16" (1519) 19.13 (1.78) 19.77 (1.84) 19 9/16" (497) 27.06 (2.51) widest clear opening 2660-2 ◊9.92 (0.92) 21 11/16" (551) 65 13/16" (1671) 21.07 (1.96) 21.76 (2.02) 13 9/16" (344) 29.54 (2.74) widest clear opening 2920-2 2.52 (0.23) 20 3/8" (518) 17 13/16" (452) 6.29 (0.58) 6.63 (0.62) 61 9/16" (1564) 10.69 (0.99) wash mode 2926-2 3.37 (0.31) 20 3/8" (518) 23 13/16" (605) 8.48 (0.79) 8.86 (0.82) 55 9/16" (1411) 13.42 (1.25) wash mode 2930-2 4.22 (0.39) 20 3/8" (518) 29 13/16" (757) 10.66 (0.99) 11.10 (1.03) 49 9/16" (1259) 16.15 (1.50) wash mode 2936-2 ◊6.08 (0.57) 24 1/2" (621) 35 13/16" (909) 12.85 (1.19) 13.33 (1.24) 43 9/16" (1106) 18.88 (1.75) widest clear opening 2940-2 ◊5.92 (0.55) 20 3/8" (518) 41 13/16" (1062) 15.04 (1.40) 15.56 (1.45) 37 9/16" (954) 21.61 (2.01) wash mode 2946-2 ◊6.77 (0.63) 20 3/8" (518) 47 13/16" (1214) 17.23 (1.60) 17.80 (1.65) 31 9/16" (802) 24.34 (2.26) wash mode 2950-2 ◊7.62 (0.71) 20 3/8" (518) 53 13/16" (1367) 19.41 (1.80) 20.03 (1.86) 25 9/16" (649) 27.06 (2.51) wash mode 2956-2 ◊8.47 (0.79) 20 3/8" (518) 59 13/16" (1519) 21.60 (2.01) 22.27 (2.07) 19 9/16" (497) 29.79 (2.77) wash mode 2960-2 ◊9.32 (0.87) 20 3/8" (518) 65 13/16" (1671) 23.79 (2.21) 24.50 (2.28) 13 9/16" (344) 32.52 (3.02) wash mode 3020-2 2.89 (0.27) 23 3/8" (594) 17 13/16" (452) 7.01 (0.65) 7.37 (0.68) 61 9/16" (1564) 11.67 (1.08) wash mode 3026-2 3.87 (0.36) 23 3/8" (594) 23 13/16" (605) 9.45 (0.88) 9.86 (0.92) 55 9/16" (1411) 14.65 (1.36) wash mode 3030-2 4.84 (0.45) 23 3/8" (594) 29 13/16" (757) 11.88 (1.10) 12.34 (1.15) 49 9/16" (1259) 17.63 (1.64) wash mode 3036-2 ◊5.82 (0.54) 23 3/8" (594) 35 13/16" (909) 14.32 (1.33) 14.82 (1.38) 43 9/16" (1106) 20.61 (1.91) wash mode 3040-2 ◊6.79 (0.63) 23 3/8" (594) 41 13/16" (1062) 16.76 (1.56) 17.31 (1.61) 37 9/16" (954) 23.59 (2.19) wash mode 3046-2 ◊7.77 (0.72) 23 3/8" (594) 47 13/16" (1214) 19.20 (1.78) 19.79 (1.84) 31 9/16" (802) 26.56 (2.47) wash mode 3050-2 ◊8.74 (0.81) 23 3/8" (594) 53 13/16" (1367) 21.63 (2.01) 22.27 (2.07) 25 9/16" (649) 29.54 (2.74) wash mode 3056-2 ◊9.72 (0.90) 23 3/8" (594) 59 13/16" (1519) 24.07 (2.24) 24.76 (2.30) 19 9/16" (497) 32.52 (3.02) wash mode 3060-2 ◊10.69 (0.99) 23 3/8" (594) 65 13/16" (1671) 26.51 (2.46) 27.24 (2.53) 13 9/16" (344) 35.50 (3.30) wash mode Prairie A Colonial Colonial Meeting Rail Fractional Fractional Victorian Casement Grille Patterns Modied Simulated Tall Short • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). *To calculate alternative hinge type, see page 94. (continued) 24 CASEMENT & AWNING WINDOWS Low-E Glass Insect Screen Window Dimension Width Minimum Rough Opening Clear Opening Width 1 3 ⁄ 8" (3 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) Unobstructed Glass2 7 ⁄8" (73) 2 7⁄8" (73) 1 ⁄4" (6) jambjamb width sash projection 16 14 29 ⁄32" (379) 19 17 29 ⁄32" (455) 20 20 29 ⁄32" (531) 23 23 29 ⁄32" (607) 26 26 29 ⁄32" (683) 29 29 29⁄32" (760) 30 32 29 ⁄32" (836) Andersen® Extension Jamb Attachment Flange (optional) Casement Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Vertical Section Stucco Exterior • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. Horizontal Section Stucco Exterior Horizontal Section Low-E Glass Insect Screen3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1 3 ⁄8" (35) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 1 ⁄4" (6 ) sill head Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 2 7⁄8" (73) 1 7⁄16" (37) Low-E Glass Insect Screen3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1" (25) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 1 ⁄ 8" (3 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄ 8" (3 ) 1 ⁄4" (6 ) sill head Sill Stop to Suboor Dimension1 7⁄16" (37) 2 7⁄8" (73) 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) Low-E Glass Insect Screen jambjamb 2 7⁄8" (73) 2 7⁄8" (73) Horizontal Section Twin Casement Horizontal Section Picture With Flanking Casement 6 3 ⁄4" (171) 6 3 ⁄4" (171) In t e g r a l s See pages 88-93 for joining details. 25 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 100 SERIES Casement Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Existing Framed Opening Horizontal Section Existing Framed Opening Low-E Glass Insect Screen Andersen® Exterior Sill Extender Trim (optional) 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Ex i s t i n g O p e n i n g Un o b s t r . Gl a s s 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 3 1 ⁄4" (83) 1 ⁄4" (6 ) sill head Sill Stop to Suboor Dimension 2 7 ⁄8" (73) 1 7⁄16" (37) No F l a n g e (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) 2 7⁄8" (73) 2 7⁄8" (73) Low-E Glass Insect Screen jambjamb Andersen® Extension Jamb Attachment Flange (optional) Vertical Section Existing Window Opening Horizontal Section Existing Window Opening In s e r t • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Fl u s h F i n * 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 1 ⁄4" (6 ) sill head Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 2 7⁄8" (73) 1 7⁄16" (37) Low-E Glass Insect Screen (79)(79) 3 1 ⁄8" Window Dimension Width Existing Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass Insect Screen jambjamb 2 7⁄8" (73) 2 7⁄8" (73) Integral details shown on previous page. Installation accessories are available for windows with insert and flush fin frames; see page 120. See pages 88-93 for joining details. Vertical Section Existing Aluminum Frame Window Opening Horizontal Section Existing Aluminum Frame Window Opening sill head 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 3 ⁄16 " (5 ) 3 1 ⁄ 8" (7 9 ) 3 ⁄16 " (5 ) 1 5 ⁄ 8" (4 1 ) 3 ⁄8" (10) 1 5 ⁄8" (4 1 ) 2 7⁄8" (73) 1 7⁄16" (37) Sill Stop to Suboor Dimension Low-E Glass Insect Screen Andersen® Interior Flat Trim (79)(79) 3 1 ⁄8" Window Dimension Width Existing Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 3 ⁄16" (5) 3 ⁄16" (5) 3 ⁄ 8" (1 0 ) 1 5 ⁄8" (41) 1 5 ⁄8" (41) 2 7⁄8" (73) 2 7⁄8" (73) jambjamb Low-E Glass Insect Screen Andersen® Interior Flat Trim 26 CASEMENT & AWNING WINDOWS Custom-size windows are available in 1 ⁄8" (3) increments. See page 95 for custom sizes and specifications. Windows have one continuous outer frame. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 28. Details shown on pages 30-31. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Custom-size windows are available in 1 ⁄8" (3) increments. See page 95 for custom sizes and specifications.2616 301616162016 2620 302016202020 2626 302616262026 2630 303020301630 3616 3620 3626 3630 4016 4020 4026 4030 Window Dimension Unobstructed Glass Minimum Rough Opening Table of Awning Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 CU S T O M H E I G H T S — 17 1 ⁄ 2" t o 35 1 ⁄2" CUSTOM WIDTHS — 17 1 ⁄2" to 47 1 ⁄2" 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 11 1/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 17 1/4" 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 1' - 1 1 1/2" 11 1/4" 1' - 5 1/2" 1' - 6 " (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (597) (610) (438) (59 7 ) (61 0 ) (43 8 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (44 5 ) (45 7 ) (28 6 ) 2020-21620-2 1920-2 2026-21626-2 1926-2 2030-21630-2 1930-2 2320-2 2620-2 2920-2 2326-2 2626-2 2926-2 2330-2 2630-2 2930-2 2010-2 2310-2 2610-2 2910-21610-2 1910-2 2016-2 2316-2 2616-2 2916-21616-2 1916-2 2020-2 2320-2 2620-2 2920-21620-2 1920-2 3020-2 3026-2 3030-2 3010-2 3016-2 3020-2 2016-21616-2 2316-2 2616-2 2916-2 3016-21916-2 Window Dimension Unobstructed Glass (width of single sash) Minimum Rough Opening Table of Twin Awning Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 CUSTOM WIDTHS — 35 1 ⁄2" to 71 1 ⁄2" CU S T O M H E I G H T S — 17 1 ⁄2" t o 35 1 ⁄ 2" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 17 1/4" 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 1' - 1 1 1/2" 11 1/4" 1' - 5 1/2" 1' - 6 " 11 1/4" 2'-11 1/2" 3'-0" 17 1/4" 3'-11 1/2" 4'-0" 14 1/4" 3'-5 1/2" 3'-6" 4'-5 1/2" 4'-6" 20 1/4"23 1/4" 4'-11 1/2" 5'-0" 26 1/4" 5'-5 1/2" 5'-6"6'-0" 5'-11 1/2" 29 1/4" (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (59 7 ) (61 0 ) (43 8 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (44 5 ) (45 7 ) (28 6 ) (902) (914) (286) (1207) (1219) (438) (1054) (1067) (362) (1359) (1372) (514) (1511) (1524) (591) (1664) (1676) (667) (1816) (1829) (743) Choose venting or stationary. Awning windows must be installed to vent as shown and should not be rotated and used as a hopper. Grille patterns shown on page 28. Details shown on pages 30-31. Venting StationaryVentingStationary 27 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. 20202020 26202620 30203020 36203620 40204020 20262026 26262626 20302030 26302630 30303030 36303630 40304030 20402020 26402620 30403020 36403620 40404020 20402030 26402630 30403030 36403630 40404030 20502020 26502620 30503020 36503620 40504020 20502030 26502630 30503030 36503630 40504030 30263026 36263626 40264026 Window Dimension Unobstructed Glass (height of upper sash) Minimum Rough Opening Table of Picture Window Over Awning Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 17 1/4" 1'-11 1/2" 2'-0" 3' - 1 1 1/2" 4' - 0 " 17 1/4" 4' - 1 1 1/2" 5' - 0 " 23 1/4" 5' - 1 1 1/2" 6' - 0 " 29 1/4" 7' - 0 " 6' - 1 1 1/2" 35 1/4" 7' - 1 1 1/2" 8' - 0 " 53 1/4" 5' - 1 1 1/2" 6' - 0 " 35 1/4" 7' - 0 " 6' - 1 1 1/2" 53 1/4" (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (597) (610) (438) (18 1 6 ) (18 2 9 ) (74 3 ) (12 0 7 ) (12 1 9 ) (61 0 ) (15 1 1 ) (15 2 4 ) (59 1 ) (2 1 2 1 ) (21 3 4 ) (89 5 ) (24 2 6 ) (24 3 8 ) (13 5 3 ) (18 1 6 ) (18 2 9 ) (89 5 ) (2 1 2 1 ) (21 3 4 ) (13 5 3 ) CU S T O M H E I G H T S — 47 1 ⁄2" t o 95 1 ⁄2" CUSTOM WIDTHS — 17 1 ⁄2" to 47 1 ⁄2" Custom ExampleSpecied Equal Light Examples Number of lights and overall pattern varies with window size. Patterns may not be available in all configurations or sizes. Specified equal light and custom patterns are also available. For specified equal light, specify number of same-size rectangles across or down. For more grille options, see page 14 or visit andersenwindows.com/grilles. Prairie A Colonial Colonial* Modied Awning Grille Patterns Fractional Fractional Tall Short Custom-size windows are available in 1 ⁄8" (3) increments. See page 95 for custom sizes and specifications. Windows have one continuous outer frame. For unobstructed glass height dimensions of lower sash, see page 27. Grille patterns shown below. Details shown on pages 30-31. *Modified colonial pattern is only available for the upper sash of a picture window over awning configuration. 28 CASEMENT & AWNING WINDOWS Awning Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Depth Inches/(mm) 1616 0.66 (0.06) 11 13/16" (300) 8" (203) 0.88 (0.08) 0.66 (0.06) 67 9/16" (1716) 2.13 (0.20) 1620 0.66 (0.06) 11 13/16" (300) 8" (203) 1.35 (0.13) 0.66 (0.06) 61 9/16" (1564) 2.86 (0.27) 1626 0.66 (0.06) 11 13/16" (300) 8" (203) 1.82 (0.17) 0.66 (0.06) 55 9/16" (1411) 3.59 (0.33) 1630 0.66 (0.06) 11 13/16" (300) 8" (203) 2.29 (0.21) 0.66 (0.06) 49 9/16" (1259) 4.31 (0.40) 2016 0.99 (0.09) 17 13/16" (452) 8" (203) 1.35 (0.13) 0.99 (0.09) 67 9/16" (1716) 2.86 (0.27) 2020 0.99 (0.09) 17 13/16" (452) 8" (203) 2.07 (0.19) 0.99 (0.09) 61 9/16" (1564) 3.84 (0.36) 2026 0.99 (0.09) 17 13/16" (452) 8" (203) 2.79 (0.26) 0.99 (0.09) 55 9/16" (1411) 4.81 (0.45) 2030 0.99 (0.09) 17 13/16" (452) 8" (203) 3.50 (0.33) 0.99 (0.09) 49 9/16" (1259) 5.79 (0.54) 2616 1.32 (0.12) 23 13/16" (605) 8" (203) 1.82 (0.17) 1.32 (0.12) 67 9/16" (1716) 3.59 (0.33) 2620 1.32 (0.12) 23 13/16" (605) 8" (203) 2.79 (0.26) 1.32 (0.12) 61 9/16" (1564) 4.81 (0.45) 2626 1.32 (0.12) 23 13/16" (605) 8" (203) 3.75 (0.35) 1.32 (0.12) 55 9/16" (1411) 6.04 (0.56) 2630 1.32 (0.12) 23 13/16" (605) 8" (203) 4.72 (0.44) 1.32 (0.12) 49 9/16" (1259) 7.27 (0.68) 3016 1.66 (0.15) 29 13/16" (757) 8" (203) 2.29 (0.21) 1.66 (0.15) 67 9/16" (1716) 4.31 (0.40) 3020 1.66 (0.15) 29 13/16" (757) 8" (203) 3.50 (0.33) 1.66 (0.15) 61 9/16" (1564) 5.79 (0.54) 3026 1.66 (0.15) 29 13/16" (757) 8" (203) 4.72 (0.44) 1.66 (0.15) 55 9/16" (1411) 7.27 (0.68) 3030 1.66 (0.15) 29 13/16" (757) 8" (203) 5.94 (0.55) 1.66 (0.15) 49 9/16" (1259) 8.75 (0.81) 3616 1.99 (0.18) 35 13/16" (909) 8" (203) 2.75 (0.26) 1.99 (0.18) 67 9/16" (1716) 5.04 (0.47) 3620 1.99 (0.18) 35 13/16" (909) 8" (203) 4.22 (0.39) 1.99 (0.18) 61 9/16" (1564) 6.77 (0.63) 3626 1.99 (0.18) 35 13/16" (909) 8" (203) 5.69 (0.53) 1.99 (0.18) 55 9/16" (1411) 8.50 (0.79) 3630 1.99 (0.18) 35 13/16" (909) 8" (203) 7.16 (0.67) 1.99 (0.18) 49 9/16" (1259) 10.23 (0.95) 4016 2.32 (0.22) 41 13/16" (1062) 8" (203) 3.22 (0.30) 2.32 (0.22) 67 9/16" (1716) 5.77 (0.54) 4020 2.32 (0.22) 41 13/16" (1062) 8" (203) 4.94 (0.46) 2.32 (0.22) 61 9/16" (1564) 7.75 (0.72) 4026 2.32 (0.22) 41 13/16" (1062) 8" (203) 6.66 (0.62) 2.32 (0.22) 55 9/16" (1411) 9.73 (0.90) 4030 2.32 (0.22) 41 13/16" (1062) 8" (203) 8.38 (0.78) 2.32 (0.22) 49 9/16" (1259) 11.71 (1.09) Twin Awning Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Depth Inches/(mm) 1616-2 0.66 (0.06) 11 13/16" (300) 8" (203) 1.76 (0.16) 1.31 (0.12) 67 9/16" (1716) 4.31 (0.40) 1620-2 0.66 (0.06) 11 13/16" (300) 8" (203) 2.70 (0.25) 1.31 (0.12) 61 9/16" (1564) 5.79 (0.54) 1626-2 0.66 (0.06) 11 13/16" (300) 8" (203) 3.63 (0.34) 1.31 (0.12) 55 9/16" (1411) 7.27 (0.68) 1630-2 0.66 (0.06) 11 13/16" (300) 8" (203) 4.57 (0.42) 1.31 (0.12) 49 9/16" (1259) 8.75 (0.81) 1916-2 0.82 (0.08) 14 13/16" (376) 8" (203) 2.23 (0.21) 1.65 (0.15) 67 9/16" (1716) 5.04 (0.47) 1920-2 0.82 (0.08) 14 13/16" (376) 8" (203) 3.41 (0.32) 1.65 (0.15) 61 9/16" (1564) 6.77 (0.63) 1926-2 0.82 (0.08) 14 13/16" (376) 8" (203) 4.60 (0.43) 1.65 (0.15) 55 9/16" (1411) 8.50 (0.79) 1930-2 0.82 (0.08) 14 13/16" (376) 8" (203) 5.79 (0.54) 1.65 (0.15) 49 9/16" (1259) 10.23 (0.95) 2016-2 0.99 (0.09) 17 13/16" (452) 8" (203) 2.70 (0.25) 1.98 (0.18) 67 9/16" (1716) 5.77 (0.54) 2020-2 0.99 (0.09) 17 13/16" (452) 8" (203) 4.13 (0.38) 1.98 (0.18) 61 9/16" (1564) 7.75 (0.72) 2026-2 0.99 (0.09) 17 13/16" (452) 8" (203) 5.57 (0.52) 1.98 (0.18) 55 9/16" (1411) 9.73 (0.90) 2030-2 0.99 (0.09) 17 13/16" (452) 8" (203) 7.01 (0.65) 1.98 (0.18) 49 9/16" (1259) 11.71 (1.09) 2316-2 1.16 (0.11) 20 13/16" (528) 8" (203) 3.16 (0.29) 2.31 (0.21) 67 9/16" (1716) 6.50 (0.60) 2320-2 1.16 (0.11) 20 13/16" (528) 8" (203) 4.85 (0.45) 2.31 (0.21) 61 9/16" (1564) 8.73 (0.81) 2326-2 1.16 (0.11) 20 13/16" (528) 8" (203) 6.54 (0.61) 2.31 (0.21) 55 9/16" (1411) 10.96 (1.02) 2330-2 1.16 (0.11) 20 13/16" (528) 8" (203) 8.23 (0.76) 2.31 (0.21) 49 9/16" (1259) 13.19 (1.23) 2616-2 1.32 (0.12) 23 13/16" (605) 8" (203) 3.63 (0.34) 2.65 (0.25) 67 9/16" (1716) 7.23 (0.67) 2620-2 1.32 (0.12) 23 13/16" (605) 8" (203) 5.57 (0.52) 2.65 (0.25) 61 9/16" (1564) 9.71 (0.90) 2626-2 1.32 (0.12) 23 13/16" (605) 8" (203) 7.51 (0.70) 2.65 (0.25) 55 9/16" (1411) 12.19 (1.13) 2630-2 1.32 (0.12) 23 13/16" (605) 8" (203) 9.45 (0.88) 2.65 (0.25) 49 9/16" (1259) 14.67 (1.36) 2916-2 1.49 (0.14) 26 13/16" (681) 8" (203) 4.10 (0.38) 2.98 (0.28) 67 9/16" (1716) 7.96 (0.74) 2920-2 1.49 (0.14) 26 13/16" (681) 8" (203) 6.29 (0.58) 2.98 (0.28) 61 9/16" (1564) 10.69 (0.99) 2926-2 1.49 (0.14) 26 13/16" (681) 8" (203) 8.48 (0.79) 2.98 (0.28) 55 9/16" (1411) 13.42 (1.25) 2930-2 1.49 (0.14) 26 13/16" (681) 8" (203) 10.66 (0.99) 2.98 (0.28) 49 9/16" (1259) 16.15 (1.50) 3016-2 1.66 (0.15) 29 13/16" (757) 8" (203) 4.57 (0.42) 3.31 (0.31) 67 9/16" (1716) 8.69 (0.81) 3020-2 1.66 (0.15) 29 13/16" (757) 8" (203) 7.01 (0.65) 3.31 (0.31) 61 9/16" (1564) 11.67 (1.08) 3026-2 1.66 (0.15) 29 13/16" (757) 8" (203) 9.45 (0.88) 3.31 (0.31) 55 9/16" (1411) 14.65 (1.36) 3030-2 1.66 (0.15) 29 13/16" (757) 8" (203) 11.88 (1.10) 3.31 (0.31) 49 9/16" (1259) 17.63 (1.64) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. 29 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 100 SERIES Awning Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Vertical Section Stucco Exterior Horizontal Section Stucco Exterior Horizontal Section Low-E Glass Insect Screen (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass1 3 ⁄ 8" (3 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb Andersen® Extension Jamb Attachment Flange (optional) 2 7⁄8" (73) 2 7⁄8" (73) (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) Low-E Glass Insect Screen jambjamb 2 7⁄8" (73) 2 7⁄8" (73) Low-E Glass Insect Screen 1 3 ⁄8" (35) 3 1 ⁄4" (83) 2 7⁄ 8" (7 3 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d G l a s s 1 ⁄4" (6 ) 2 7⁄ 8" (7 3 ) 1 ⁄4" (6 ) 8" (203) 11" (279) Clear Opening Width Sash Projection sill head Andersen® Extension Jamb Attachment Flange (optional) 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y Low-E Glass Insect Screen3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1" (25) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 1 ⁄ 8" (3 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄8" (3 ) 1 ⁄4" (6 ) sill head Sill Stop to Suboor Dimension1 7⁄16" (37) 2 7 ⁄8" (73) • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. In t e g r a l s 6 3 ⁄4" (1 7 1 ) 6 3 ⁄4" (171) Horizontal Section Twin Awning Vertical Section Picture Over Awning See pages 88-93 for joining details. 30 CASEMENT & AWNING WINDOWS 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Ex i s t i n g O p e n i n g Un o b s t r . Gl a s s 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 3 1 ⁄4" (83) 1 ⁄4" (6 ) Low-E Glass Insect Screen Andersen® Exterior Sill Extender Trim (optional) sill head Sill Stop to Suboor Dimension1 7⁄16" (37) 2 7 ⁄8" (73) (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) 2 7 ⁄8" (73) 2 7⁄8" (73) Low-E Glass Insect Screen jambjamb Andersen® Extension Jamb Attachment Flange (optional) Awning Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Horizontal Section Existing Framed Opening Vertical Section Existing Framed Opening Horizontal Section Existing Window Opening Vertical Section Existing Window Opening (79)(79) 3 1 ⁄8" Window Dimension Width Existing Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass Insect Screen jambjamb 2 7⁄8" (73) 2 7⁄8" (73) 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 1 ⁄4" (6 ) sill head Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 2 7⁄8" (73) 1 7⁄16" (37) Low-E Glass Insect Screen No F l a n g e In s e r t • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Fl u s h F i n * Integral details shown on previous page. Installation accessories are available for windows with insert and flush fin frames; see page 120. See pages 88-93 for joining details. Horizontal Section Existing Aluminum Frame Window Opening Vertical Section Existing Aluminum Frame Window Opening sill head 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 3 ⁄16 " (5 ) 3 1 ⁄ 8" (7 9 ) 3 ⁄16 " (5 ) 1 5 ⁄ 8" (4 1 ) 3 ⁄8" (10) 1 5 ⁄ 8" (4 1 ) Sill Stop to Suboor Dimension 2 7⁄8" (73) 1 7⁄16" (37) Low-E Glass Insect Screen Andersen® Interior Flat Trim Window Dimension Width Existing Opening 3 1 ⁄4" (8 3 ) 3 ⁄16" (5) 3 ⁄16" (5) 3 ⁄ 8" (1 0 ) 1 5 ⁄8" (41) 1 5 ⁄8" (41) 2 7⁄8" (73) 2 7⁄8" (73) jambjamb (79)(79) 3 1 ⁄8"3 1 ⁄8"Unobstr. Glass Low-E Glass Insect Screen Andersen® Interior Flat Trim 31 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. • Arch single-hung windows are not available with the flush fin frame option. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on pages 33 and 41. 30402640 36402040 30462646 36462046 30502650 36502050 30562656 36562056 30602660 36602060 30662666 36662066 2030 363026303030 2026 362626263026 2636 363620363036 Table of Arch Single-Hung Window Sizes Window Width Dimension Minimum Rough Opening 23 1 ⁄2"29 1 ⁄2"35 1 ⁄2"41 1 ⁄2" Si d e H e i g h t Radius Chord Height Mi n i m u m R o u g h O p e n i n g = W i n d o w H e i g h t + 1 ⁄ 2" 3 1 ⁄ 8" 4"4 3 ⁄4" 5 1 ⁄ 2" Unobstructed Glass (width of upper sash) Unobstructed Glass (width of lower sash) 15 1/16"15 7/8"16 11/16"17 1/2" 18 1/16"18 7/8"19 11/16"20 1/2" 21 1/16"21 7/8"22 11/16"23 1/2" 24 1/16"24 7/8"25 11/16"26 1/2" 27 1/16"27 7/8"28 11/16"29 1/2" 30 1/16"30 7/8"31 11/16"32 1/2" 33 1/16"33 7/8"34 11/16"35 1/2" 36 1/16"36 7/8"37 11/16"38 1/2" 39 1/16"39 7/8"40 11/16"41 1/2" 1'-11 1/2" 2'-0" 20" 2'-5 1/2" 3'-6" 3'-5 1/2" 2'-6" 26"38"32" 2'-11 1/2" 3'-0" 17 1/4" 10 9/16" 13 9/16" 16 9/16" 19 9/16" 22 9/16" 25 9/16" 28 9/16" 31 9/16" 34 9/16" 23 1/4"29 1/4"35 1/4" 2' - 1 1 " 3' - 5 " 3' - 1 1 " (1 0 4 1 ) 4' - 5 " 4' - 1 1 " 5' - 5 " 5' - 1 1 " 6' - 5 " 6 ' - 1 1 " (1 0 2 ) (1 2 1 ) 2' - 1 0 1/4" 2' - 9 1/2" 3' - 4 1/4" 3' - 3 1/2" 3' - 1 0 1/4" 3' - 9 1/2" 4' - 4 1/4" 4' - 3 1/2" 4' - 1 0 1/4" 4' - 9 1/2" 5' - 4 1/4" 5' - 3 1/2" 5' - 1 0 1/4" 5' - 9 1/2" 6' - 4 1/4" 6' - 3 1/2" 6 ' - 1 0 1/4" 6' - 9 1/2" (403) (479) (556) (632) (708) (784) (860) (937) (1013) 2' - 5 1 ⁄2" 2 ' - 1 1 1 ⁄ 2" 3' - 5 1 ⁄ 2" 2' - 8 5/8" 3' - 2 5/8" 3' - 8 5/8" 3' - 1 1 1 ⁄ 2" 4' - 2 5/8" 4' - 5 1 ⁄2" 4' - 8 5/8" 4' - 1 1 1 ⁄ 2" 5' - 2 5/8" 5' - 5 1 ⁄ 2" 5' - 8 5/8" 5' - 1 1 1 ⁄ 2" 6' - 2 5/8" 6' - 5 1 ⁄ 2" 6' - 8 5/8" Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 UnobstructedGlass (height of lower sash shown below) Unobstructed Glass (height of upper sash shown to right of window) Wi n d o w H e i g h t (s h o w n l e f t o f w i n d o w ) (902)(1054)(597)(749) (1 3 ) (7 9 ) (1 4 0 ) (8 2 9 ) (9 8 1 ) (1 1 3 3 ) (8 8 9 ) (1 1 9 4 ) (7 4 9 ) (9 0 2 ) (1 0 5 4 ) (8 7 0 ) (1 0 2 2 ) (1 1 7 5 ) (8 5 1 ) (1 0 0 3 ) (1 1 5 6 ) (1 2 8 6 ) (1 3 4 6 ) (1 2 0 7 ) (1 3 2 7 ) (1 3 0 8 ) (1 4 3 8 ) (1 4 9 9 ) (1 3 5 9 ) (1 4 8 0 ) (1 4 6 1 ) (1 5 9 1 ) (1 6 5 1 ) (1 5 1 1 ) (1 6 3 2 ) (1 6 1 3 ) (1 7 4 3 ) (1 8 0 3 ) (1 6 6 4 ) (1 7 8 4 ) (1 7 6 5 ) (1 8 9 5 ) (1 9 5 6 ) (1 8 1 6 ) (1 9 3 7 ) (1 9 1 8 ) (2 0 4 8 ) (2 1 0 8 ) (1 9 6 9 ) (2 0 8 9 ) (2 0 7 0 ) (383)(424)(445) (459)(500)(521) (535)(576)(597) (611)(652)(673) (687)(729)(749) (764)(805)826) (840)(881)(902) (916)(957)(978) (992)(1033)(1054) (749) (762) (660) (597) (610) (508) (1054) (1067) (965) (902) (914) (813) (438) (268) (345) (421) (497) (573) (649) (726) (802) (878) (591)(743)(895) continued on next page Custom-size windows are available in 1 ⁄8" (3) increments. Contact your Andersen supplier for more information. For arch single-hung windows, the size designation does not reflect the overall window height (e.g., a 2026 window size has a side height of 2'-5 1 ⁄2" and an overall window height of 2'-8 5 ⁄8"). Height dimensions for upper sash are shown to the right of each window size and for lower sash are to the far left. Grille patterns shown on page 49. Details shown on pages 50-51. 32 SINGLE-HUNG WINDOWS • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. • Arch single-hung windows are not available with the flush fin frame option. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on pages 33 and 41. *For side heights greater than 6'-5 1/2" (1969), meeting rail location = (side height in inches x 0.33) + 1.96". 30702670 36702070 30762676 36762076 Table of Arch Single-Hung Window Sizes Window Width Dimension Minimum Rough Opening 23 1 ⁄2"29 1 ⁄2"35 1 ⁄2"41 1 ⁄2" Mi n . Ro u g h O p e n i n g = W i n d o w H e i g h t + 1 ⁄ 2" 3 1 ⁄ 8" 4"4 3 ⁄4" 5 1 ⁄ 2" 55"55 13/16"56 9/16"57 3/8" 59"59 13/16"60 9/16"61 3/8" 1'-11 1/2" 2'-0" 20" 2'-5 1/2" 3'-6" 3'-5 1/2" 2'-6" 26"38"32" 2'-11 1/2" 3'-0" 17 1/4" 24 11/16" 26 11/16" 23 1/4"29 1/4"35 1/4" 7' - 5 " (2 2 6 1 ) 7' - 1 1 " (1 0 2 ) (1 2 1 ) 7' - 4 1/4" 7' - 3 1/2" 7 ' - 1 0 1/4" 7' - 9 1/2" (1418) (1519) 6' - 1 1 1 ⁄2" 7' - 2 5/8" 7' - 5 1 ⁄ 2" 7' - 8 5/8" Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 Si d e H e i g h t Radius Chord Height Unobstructed Glass (width of upper sash) Unobstructed Glass (width of lower sash) UnobstructedGlass (height of lower sash shown below) Unobstructed Glass (height of upper sash shown to right of window) Wi n d o w H e i g h t (s h o w n l e f t o f w i n d o w ) (902)(1054)(597)(749) (1 3 ) (7 9 ) (1 4 0 ) (2 2 0 0 ) (2 1 2 1 ) (2 2 4 2 ) (2 2 2 3 ) (2 3 5 3 ) (2 4 1 3 ) (2 2 7 3 ) (2 3 9 4 ) (2 3 7 5 ) (1397)(1437)(1457) (1499)(1538)(1559) (749) (762) (660) (597) (610) (508) (1054) (1067) (965) (902) (914) (813) (438) (627) (678) (591)(743)(895) Windows with a side height greater than 6'-5 1 ⁄2" (1969) are only available with a 2:1 reverse cottage sash ratio.* (continued) Reverse Cottage* 2 1 Arch Single-Hung Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 2026 1.53 (0.14) 20" (508) 11 1/16"(280) 3.25 (0.30) 1.53 (0.14) 51 3/8"(1304) 5.16 (0.48) 2030 1.95 (0.18) 20"(508) 14 1/16"(357) 4.03 (0.37) 1.95 (0.18) 45 3/8"(1152) 6.14 (0.57) 2036 2.37 (0.22) 20"(508) 17 1/16"(433) 4.80 (0.45) 2.37 (0.22) 39 3/8"(1000) 7.12 (0.66) 2040 2.78 (0.26) 20"(508) 20 1/16"(509) 5.58 (0.52) 2.78 (0.26) 33 3/8"(847) 8.10 (0.75) 2046 3.20 (0.30) 20"(508) 23 1/16"(585) 6.36 (0.59) 3.20 (0.30) 27 3/8"(695) 9.08 (0.84) 2050 3.62 (0.34) 20"(508) 26 1/16"(661) 7.13 (0.66) 3.62 (0.34) 21 3/8"(542) 10.06 (0.93) 2056 4.03 (0.37) 20"(508) 29 1/16"(738) 7.91 (0.73) 4.03 (0.37) 15 3/8"(390) 11.04 (1.03) 2060 4.45 (0.41) 20"(508) 32 1/16"(814) 8.68 (0.81) 4.45 (0.41) 9 3/8"(238) 12.02 (1.12) 2066 4.87 (0.45) 20"(508) 35 1/16"(890) 9.46 (0.88) 4.87 (0.45) 16 7/8"**(429)**12.99 (1.21) 2070*3.48 (0.32) 20"(508) 25 1/16"(636) 10.48 (0.97) 3.48 (0.32) 10 7/8"**(276)**13.97 (1.30) 2076*3.76 (0.35) 20"(508) 27 1/16"(687) 11.28 (1.05) 3.76 (0.35) 4 7/8"**(124)**14.95 (1.39) 2626 1.99 (0.19) 26"(660) 11 1/16"(280) 4.39 (0.41) 1.99 (0.19) 50 9/16"(1284) 6.59 (0.61) 2630 2.53 (0.24) 26"(660) 14 1/16"(357) 5.41 (0.50) 2.53 (0.24) 44 9/16"(1132) 7.82 (0.73) 2636 3.08 (0.29) 26"(660) 17 1/16"(433) 6.44 (0.60) 3.08 (0.29) 38 9/16"(979) 9.05 (0.84) 2640 3.62 (0.34) 26"(660) 20 1/16"(509) 7.46 (0.69) 3.62 (0.34) 32 9/16"(827) 10.28 (0.95) 2646 4.16 (0.39) 26"(660) 23 1/16"(585) 8.49 (0.79) 4.16 (0.39) 26 9/16"(674) 11.51 (1.07) 2650 4.70 (0.44) 26"(660) 26 1/16"(661) 9.52 (0.88) 4.70 (0.44) 20 9/16"(522) 12.74 (1.18) 2656 5.24 (0.49) 26"(660) 29 1/16"(738) 10.54 (0.98) 5.24 (0.49) 14 9/16"(370) 13.97 (1.30) 2660 ◊5.78 (0.54) 26"(660) 32 1/16"(814) 11.57 (1.07) 5.78 (0.54) 8 9/16"(217) 15.20 (1.41) 2666 ◊6.33 (0.59) 26"(660) 35 1/16"(890) 12.59 (1.17) 6.33 (0.59) 16 1/16"**(429)**16.42 (1.53) 2670*4.52 (0.42) 26"(660) 25 1/16"(636) 13.87 (1.29) 4.52 (0.42) 10 1/16"**(256)**17.65 (1.64) 2676*4.88 (0.45) 26"(660) 27 1/16"(687) 14.91 (1.39) 4.88 (0.45) 4 1/16"**(103)**18.88 (1.75) 3026 2.45 (0.23) 32"(813) 11 1/16"(280) 5.57 (0.52) 2.45 (0.23) 49 3/4"(1263) 8.07 (0.75) 3030 3.12 (0.29) 32"(813) 14 1/16"(357) 6.84 (0.64) 3.12 (0.29) 43 3/4"(1111) 9.54 (0.89) continued on page 41 • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096) except for XX66, XX70 and XX76 heights, which are calculated using a header height of 8' (2438). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). *Available only with a 2:1 reverse cottage sash ratio. **Calculated based upon a structural header height of 8' (2438). Notes on previous page also apply to this page. 33 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES Custom-size windows are available in 1 ⁄8" (3) increments. See page 96 for custom sizes and specifications. For construction site convenience, an optional drywall pass-through window is available for removal and reinstallation of the upper and lower sash. Windows with a height greater than 6'-5 1 ⁄2" (1969) are only available with a 2:1 reverse cottage sash ratio.** To see all windows sizes with reverse cottage sash, visit andersenwindows.com/sizing. Grille patterns shown on page 49. Details shown on pages 52-54. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on page 35. †Drywall pass-through window available for these standard and reverse cottage sizes and for custom-size windows wider than 1'-11 1/2" (597) and taller than 4'-5 1/2" (1359). *For reverse cottage sash windows, meeting rail location = (window height in inches x 0.40) + 1.96". **For heights greater than 6'-5 1/2" (1969), meeting rail location = (window height in inches x 0.33) + 1.96". 2620 3020 3620 40201620 2020 2626 3026 3626 402616262026 2630 3030 3630 403016302030 2636 3036 3636 403616362036 2640 3040 3640 404016402040 2646 3046 3646 404616462046 2650 †3050 †3650 †4050 †1650 2050 2656†3056 †3656 †4056 †1656 2056 2660 †3060 †3660 †4060 †1660 2060 2666 †3066 †3666 †4066 †1666 2066 2670†3070†3670 †4070 †1670 2070 Reverse Cottage* 3 2 Window Dimension Unobstructed Glass (height of single sash) Minimum Rough Opening Table of Single-Hung Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 CU S T O M H E I G H T S — 23 1 ⁄2" t o 77 1 ⁄2" CUSTOM WIDTHS — 17 1 ⁄2" to 47 1 ⁄2" 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 11 1/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 7 9/16 " 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 13 9/16 " 2' - 6 " 2' - 5 1/2" 10 9/16 " 3' - 5 1/2" 3' - 6 " 16 9/16 " 3' - 1 1 1/2" 4' - 0 " 19 9/16 " 4' - 5 1/2" 4' - 6 " 22 9/16 " 4' - 1 1 1/2" 5' - 0 " 25 9/16 " 5' - 5 1/2" 5' - 6 " 28 9/16 " 5' - 1 1 1/2" 6' - 0 " 31 9/16 " 1' - 1 1 1/2" 7' - 0 " 6' - 1 1 1/2" 6' - 5 1/2" 6' - 6 " 34 9/16 " 50 7/16" 24 5/8" CU S T O M HE I G H T S (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (597) (610) (438) (59 7 ) (61 0 ) (19 2 ) (7 4 9 ) (76 2 ) (26 8 ) (90 2 ) (91 4 ) (34 5 ) (16 6 4 ) (16 7 6 ) (72 6 ) (18 1 6 ) (18 2 9 ) (80 2 ) (12 0 7 ) (12 1 9 ) (49 7 ) (13 5 9 ) (57 3 ) (15 1 1 ) (15 2 4 ) (64 9 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (42 1 ) (2 1 2 1 ) (21 3 4 ) (19 6 9 ) (19 8 1 ) (87 8 ) (1282) (626) Reverse cottage sash is available based on a 3:2 ratio. Available in standard widths for the heights shown below. REVERSE COTTAGE CUSTOM WIDTHS — 17 1/2" (445) to 47 1/2" (1207) REVERSE COTTAGE CUSTOM HEIGHTS — 29 1/2" (749) to 77 1/2" (1969) continued on next page Reverse Cottage* 2 1 2:1 sash ratio is not available for heights 6'-5 1/2" (1969) and less. 34 SINGLE-HUNG WINDOWS 2676†3076 †3676 †4076 †1676 2076 2 1 Window Dimension Unobstructed Glass Minimum Rough Opening Table of Single-Hung Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 11 1/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 7' - 5 1/2" 7' - 6 " 54 7/16" 26 5/8" (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (597) (610) (438) (22 7 3 ) (22 8 6 )(1383) (676) CU S T O M HE I G H T S CUSTOM WIDTHS (continued) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table below. †Drywall pass-through window available for these standard and reverse cottage sizes and for custom-size windows wider than 1'-11 1/2" (597) and taller than 4'-5 1/2" (1359). *For heights greater than 6'-5 1/2" (1969), meeting rail location = (window height in inches x 0.33) + 1.96". Windows with a height greater than 6'-5 1 ⁄2" (1969) are only available with a 2:1 reverse cottage sash ratio.* To see all windows sizes with reverse cottage sash, visit andersenwindows.com/sizing. Reverse Cottage* 2 1 Single-Hung Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Height Inches/(mm) 1620 0.78 (0.07) 14" (356) 8 1/16"(204) 1.18 (0.11) 0.78 (0.07) 60 1/2"(1537) 2.86 (0.27) 1626 1.07 (0.10) 14" (356) 11 1/16"(280) 1.65 (0.15) 1.07 (0.10) 54 1/2"(1384) 3.59 (0.33) 1630 1.37 (0.13) 14" (356) 14 1/16"(357) 2.12 (0.20) 1.37 (0.13) 48 1/2"(1232) 4.31 (0.40) 1636 1.66 (0.15)14" (356) 17 1/16"(433) 2.59 (0.24) 1.66 (0.15) 42 1/2"(1080) 5.04 (0.47) 1640 1.95 (0.18) 14" (356) 20 1/16"(509) 3.05 (0.28) 1.95 (0.18) 36 1/2"(927) 5.77 (0.54) 1646 2.24 (0.21) 14" (356) 23 1/16"(585) 3.52 (0.33) 2.24 (0.21) 30 1/2"(775) 6.50 (0.60) 1650 2.53 (0.24) 14" (356) 26 1/16"(661) 3.99 (0.37) 2.53 (0.24) 24 1/2"(622) 7.23 (0.67) 1656 2.82 (0.26) 14" (356) 29 1/16"(738) 4.46 (0.41) 2.82 (0.26) 18 1/2"(470) 7.96 (0.74) 1660 3.12 (0.29) 14" (356) 32 1/16"(814) 4.93 (0.46) 3.12 (0.29) 12 1/2"(318) 8.69 (0.81) 1666 3.41 (0.32) 14" (356) 35 1/16"(890) 5.40 (0.50) 3.41 (0.32) 6 1/2"(165) 9.42 (0.88) 1670*2.43 (0.23) 14" (356) 25 1/16"(636) 5.87 (0.55) 2.43 (0.23) 14"**(356)**10.15 (0.94) 1676*2.63 (0.24) 14" (356) 27 1/16"(687) 6.34 (0.59) 2.63 (0.24) 8"**(203)**10.88 (1.01) 2020 1.12 (0.10) 20" (508) 8 1/16"(204) 1.81 (0.17) 1.12 (0.10) 60 1/2"(1537) 3.84 (0.36) 2026 1.53 (0.14) 20" (508) 11 1/16"(280) 2.53 (0.24) 1.53 (0.14) 54 1/2"(1384) 4.81 (0.45) 2030 1.95 (0.18) 20" (508) 14 1/16"(357) 3.25 (0.30) 1.95 (0.18) 48 1/2"(1232) 5.79 (0.54) 2036 2.37 (0.22) 20" (508) 17 1/16"(433) 3.96 (0.37) 2.37 (0.22) 42 1/2"(1080) 6.77 (0.63) 2040 2.78 (0.26) 20" (508) 20 1/16"(509) 4.68 (0.44) 2.78 (0.26) 36 1/2"(927) 7.75 (0.72) 2046 3.20 (0.30) 20" (508) 23 1/16"(585) 5.40 (0.50) 3.20 (0.30) 30 1/2"(775) 8.73 (0.81) 2050 3.62 (0.34) 20" (508) 26 1/16"(661) 6.12 (0.57) 3.62 (0.34) 24 1/2"(622) 9.71 (0.90) 2056 4.03 (0.38) 20" (508) 29 1/16"(738) 6.84 (0.64) 4.03 (0.38) 18 1/2"(470) 10.69 (0.99) 2060 4.45 (0.41) 20" (508) 32 1/16"(814) 7.56 (0.70) 4.45 (0.41) 12 1/2"(318) 11.67 (1.08) 2066 4.87 (0.45) 20" (508) 35 1/16"(890) 8.28 (0.77) 4.87 (0.45) 6 1/2"(165) 12.65 (1.18) 2070*3.48 (0.32) 20" (508) 25 1/16"(636) 9.00 (0.84) 3.48 (0.32) 14"**(356)**13.63 (1.27) 2076*3.76 (0.35) 20" (508) 27 1/16"(687) 9.71 (0.90) 3.76 (0.35) 8"**(203)**14.61 (1.36) 2620 1.45 (0.14) 26" (660) 8 1/16"(204) 2.44 (0.23) 1.45 (0.14) 60 1/2"(1537) 4.81 (0.45) 2626 1.99 (0.19) 26" (660) 11 1/16"(280) 3.41 (0.32) 1.99 (0.19) 54 1/2"(1384) 6.04 (0.56) 2630 2.54 (0.24) 26" (660) 14 1/16"(357) 4.37 (0.41) 2.54 (0.24) 48 1/2"(1232) 7.27 (0.68) 2636 3.08 (0.29) 26" (660) 17 1/16"(433) 5.34 (0.50) 3.08 (0.29) 42 1/2"(1080) 8.50 (0.79) 2640 3.62 (0.34) 26" (660) 20 1/16"(509) 6.31 (0.59) 3.62 (0.34) 36 1/2"(927) 9.73 (0.90) 2646 4.16 (0.39) 26" (660) 23 1/16"(585) 7.28 (0.68) 4.16 (0.39) 30 1/2"(775) 10.96 (1.02) 2650 4.70 (0.44) 26" (660) 26 1/16"(661) 8.25 (0.77) 4.70 (0.44) 24 1/2"(622) 12.19 (1.13) 2656 5.24 (0.49) 26" (660) 29 1/16"(738) 9.22 (0.86) 5.24 (0.49) 18 1/2"(470) 13.42 (1.25) 2660 ◊5.79 (0.54) 26" (660) 32 1/16"(814) 10.19 (0.95) 5.79 (0.54) 12 1/2"(318) 14.65 (1.36) 2666 ◊6.33 (0.59) 26" (660) 35 1/16"(890) 11.16 (1.04) 6.33 (0.45) 6 1/2"(165) 15.88 (1.48) 2670*4.52 (0.42) 26" (660) 25 1/16"(636) 12.12 (1.13) 4.52 (0.42) 14"**(356)**17.11 (1.59) 2676*4.88 (0.45) 26" (660) 27 1/16"(687) 13.09 (1.22) 4.88 (0.45) 8"**(203)**18.34 (1.70) continued on page 41 For reverse cottage, twin and triple single-hung window specifications, see pages 43, 45 and 47. • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096) except for XX70 and XX76 heights, which are calculated using a header height of 8' (2438). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). *Available only with a 2:1 reverse cottage sash ratio. **Calculated based upon a structural header height of 8' (2438). Notes on previous page also apply to this page. 35 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See tables on pages 45 and 47. 2010-2 2610-21610-2 2016-2 2616-2 2020-2 2620-21620-2 3010-2 3016-2 3020-2 1616-2 2620-2 3020-2 3620-2 4020-21620-2 2020-2 2626-2 3026-2 3626-2 4026-21626-2 2026-2 2630-2 3030-2 3630-2 4030-21630-2 2030-2 2636-2 3036-2 3636-2 4036-21636-2 2036-2 2640-2 3040-2 3640-2 4040-21640-2 2040-2 2646-2 3046-2 3646-2 4046-21646-2 2046-2 2650-2 3050-2 3650-2 4050-21650-2 2050-2 3610-2 4010-2 3616-2 4016-2 3620-2 4020-2 1610-3 1616-3 1620-3 1620-3 1626-3 1630-3 1636-3 1640-3 1646-3 1650-3 1656-3 1660-3 2656-2 3056-2 3656-2 4056-21656-2 2056-2 2660-2 3060-2 3660-2 4060-21660-2 2060-2 Window Dimension Unobstructed Glass (width of single sash) Minimum Rough Opening Table of Twin and Triple Single-Hung Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 CU S T O M H E I G H T S — 23 1 ⁄2" t o 71 1 ⁄2" CUSTOM WIDTHS TWIN — 35 1 ⁄2" to 95 1 ⁄2" 11 1/4" 2'-11 1/2" 3'-0" 17 1/4" 3'-11 1/2" 4'-0" 7 9/16 " 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 13 9/16 " 2' - 6 " 2' - 5 1/2" 10 9/16 " 3' - 5 1/2" 3' - 6 " 16 9/16 " 3' - 1 1 1/2" 4' - 0 " 19 9/16 " 4' - 5 1/2" 4' - 6 " 22 9/16 " 4' - 1 1 1/2" 5' - 0 " 25 9/16 " 5' - 5 1/2" 5' - 6 " 28 9/16 " 5' - 1 1 1/2" 6' - 0 " 31 9/16 " 1' - 1 1 1/2" 23 1/4" 4'-11 1/2" 5'-0"6'-0" 5'-11 1/2" 29 1/4"35 1/4" 6'-11 1/2" 7'-0" 41 1/4" 7'-11 1/2" 8'-0" 4'-5 1/2" 4'-6" 11 1/4" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " (902) (914) (286) (1207) (1219) (438) (59 7 ) (61 0 ) (1 9 2 ) (7 4 9 ) (76 2 ) (26 8 ) (90 2 ) (91 4 ) (34 5 ) (16 6 4 ) (16 7 6 ) (72 6 ) (18 1 6 ) (18 2 9 ) (80 2 ) (12 0 7 ) (12 1 9 ) (49 7 ) (13 5 9 ) (57 3 ) (15 1 1 ) (15 2 4 ) (64 9 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (42 1 ) (1511) (1524) (591) (1816) (1829) (743) (2121) (2134) (895) (2426) (2438) (1048) (1359) (1372) (286) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) Notes on next page also apply to this page. 36 SINGLE-HUNG WINDOWS • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See tables on pages 45 and 47. Custom-size windows are available in 1 ⁄8" (3) increments. See page 96 for custom sizes and specifications. Windows have one continuous outer frame. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 49. Details shown on pages 52-54. 2010-3 2610-3 3010-3 3610-3 4010-3 2016-3 2616-3 3016-3 3616-3 4016-3 2020-3 2620-3 3020-3 3620-3 4020-3 2020-3 2620-3 3020-3 3620-3 4020-3 2026-3 2626-3 3026-3 3626-3 4026-3 2030-3 2630-3 3030-3 3630-3 4030-3 2036-3 2636-3 3036-3 3636-3 4036-3 2040-3 2640-3 3040-3 3640-3 4040-3 2046-3 2646-3 3046-3 3646-3 4040-3 2050-3 2650-3 3050-3 3650-3 4050-3 2056-3 2656-3 3056-3 3656-3 4056-3 2060-3 2660-3 3060-3 3660-3 4060-3 6'-0" 5'-11 1/2" 17 1/4"23 1/4" 7'-5 1/2" 7'-6" 29 1/4" 8'-11 1/2" 9'-0" 35 1/4" 10'-5 1/2" 10'-6" 41 1/4" 11'-11 1/2" 12'-0" CUSTOM WIDTHS TRIPLE — 53 1 ⁄2" to 143 1 ⁄2" (1816) (1829) (438) (2273) (2286) (591) (2731) (2743) (743) (3188) (3200) (895) (3645) (3658) (1048) 37 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Windows have one continuous outer frame. Unobstructed glass height dimension of upper transom sash is 5 1 ⁄4" (133). Grille patterns shown on page 49. Details shown on pages 52-54. 26102630 30103030 36103630 401040301610163020102030 26102636 30103036 36103636 401040361610163620102036 26102640 30103040 36103640 401040401610164020102040 26102646 30103046 36103646 401040461610164620102046 26102650 30103050 36103650 401040501610165020102050 26102656 30103056 36103656 401040561610165620102056 26102660 30103060 36103660 401040601610166020102060 Window Dimension Unobstructed Glass (height of individual single-hung sash only) Minimum Rough Opening Table of 10-High Transom Window Over Single-Hung Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 111/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 3' - 1 1 1/2" 4' - 0 " 13 9/16 " 4' - 5 1/2" 4' - 6 " 16 9/16 " 4' - 1 1 1/2" 5' - 0 " 19 9/16 " 5' - 5 1/2" 5' - 6 " 22 9/16 " 6' - 1 1 1/2" 7' - 0 " 31 9/16 " 6' - 6 " 6' - 5 1/2" 28 9/16 " 5' - 1 1 1/2" 6' - 0 " 25 9/16 " (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (597) (610) (438) (15 1 1 ) (15 2 4 ) (49 7 ) (16 6 4 ) (16 7 6 ) (57 3 ) (12 0 7 ) (34 5 ) (13 5 9 ) (13 7 2 ) (42 1 ) (12 1 9 ) (21 2 1 ) (21 3 4 ) (80 2 ) (1 9 6 9 ) (19 8 1 ) (72 6 ) (18 1 6 ) (18 2 9 ) (64 9 ) 38 SINGLE-HUNG WINDOWS • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Windows have one continuous outer frame. Unobstructed glass height dimension of upper transom sash is 11 1 ⁄4" (286). Grille patterns shown on page 49. Details shown on pages 52-54. 26162630 30163030 36163630 401640301616163020162030 26162636 30163036 36163636 401640361616163620162036 26162640 30163040 36163640 401640401616164020162040 26162646 30163046 36163646 401640461616164620162046 26162650 30163050 36163650 4016 40501616165020162050 26162656 30163056 36163656 401640561616165620162056 26162660 30163060 36163660 401640601616166020162060 Window Dimension Unobstructed Glass (height of individual single-hung sash only) Minimum Rough Opening Table of 16-High Transom Window Over Single-Hung Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 11 1/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 4' - 5 1/2" 4' - 6 " 13 9/16 " 4' - 1 1 1/2" 5' - 0 " 16 9/16 " 5' - 5 1/2" 5' - 6 " 19 9/16 " 5' - 1 1 1/2" 6' - 0 " 22 9/16 " 7' - 5 1/2" 7' - 6 " 31 9/16 " 7' - 0 " 6' - 1 1 1/2" 28 9/16 " 6' - 5 1/2" 6' - 6 " 25 9/16 " (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (597) (610) (438) (16 6 4 ) (16 7 6 ) (49 7 ) (18 1 6 ) (18 2 9 ) (57 3 ) (13 5 9 ) (34 5 ) (15 1 1 ) (15 2 4 ) (42 1 ) (13 7 2 ) (22 7 3 ) (22 8 6 ) (80 2 ) (2 1 2 1 ) (21 3 4 ) (72 6 ) (19 6 9 ) (19 8 1 ) (64 9 ) 39 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Windows have one continuous outer frame. Unobstructed glass height dimension of upper transom sash is 17 1 ⁄4" (438). Grille patterns shown on page 49. Details shown on pages 52-54. 26202630 30203030 36203630 402040301620163020202030 26202636 30203036 36203636 402040361620163620202036 26202640 30203040 36203640 402040401620164020202040 26202646 30203046 36203646 402040461620164620202046 26202650 30203050 36203650 402040501620165020202050 26202656 30203056 36203656 402040561620165620202056 26202660 30203060 36203660 4020 4060 16201660 20202060 Window Dimension Unobstructed Glass (height of individual single-hung sash only) Minimum Rough Opening Table of 20-High Transom Window Over Single-Hung Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" 11 1/4" 1'-5 1/2" 1'-6" 17 1/4" 1'-11 1/2" 2'-0" 4' - 1 1 1/2" 5' - 0 " 13 9/16 " 5' - 5 1/2" 5' - 6 " 16 9/16 " 5' - 1 1 1/2" 6' - 0 " 19 9/16 " 6' - 5 1/2" 6' - 6 " 22 9/16 " 7' - 1 1 1/2" 8' - 0 " 31 9/16 " 7' - 6 " 7' - 5 1/2" 28 9/16 " 6' - 1 1 1/2" 7' - 0 " 25 9/16 " (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (597) (610) (438) (1 81 6 ) (18 2 9 ) (49 7 ) (19 6 9 ) (19 8 1 ) (57 3 ) (15 1 1 ) (34 5 ) (16 6 4 ) (16 7 6 ) (42 1 ) (15 2 4 ) (24 2 6 ) (24 3 8 ) (80 2 ) (2 2 7 3 ) (22 8 6 ) (72 6 ) (21 2 1 ) (21 3 4 ) (64 9 ) 40 SINGLE-HUNG WINDOWS Arch Single-Hung Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Height Inches/(mm) 3036 3.79 (0.35) 32"(813) 17 1/16"(433) 8.12 (0.75) 3.79 (0.35) 37 3/4"(959) 11.02 (1.02) 3040 4.45 (0.41) 32"(813) 20 1/16"(509) 9.39 (0.87) 4.45 (0.41) 31 3/4"(806) 12.50 (1.16) 3046 5.12 (0.48) 32"(813) 23 1/16"(585) 10.67 (0.99) 5.12 (0.48) 25 3/4"(654) 13.98 (1.30) 3050 ◊5.79 (0.54) 32"(813) 26 1/16"(661) 11.95 (1.11) 5.79 (0.54) 19 3/4"(501) 15.46 (1.44) 3056 ◊6.45 (0.60) 32"(813) 29 1/16"(738) 13.22 (1.23) 6.45 (0.60) 13 3/4"(349) 16.94 (1.57) 3060 ◊7.12 (0.66) 32"(813) 32 1/16"(814) 14.50 (1.35) 7.12 (0.66) 7 3/4"(197) 18.42 (1.71) 3066 ◊7.79 (0.72) 32"(813) 35 1/16"(890) 15.77 (1.47) 7.79 (0.72) 15 1/4"**(387)**19.90 (1.85) 3070*5.56 (0.52) 32"(813) 25 1/16"(636) 17.30 (1.61) 5.56 (0.52) 9 1/4"**(235)**21.38 (1.99) 3076 ◊*6.01 (0.56) 32"(813) 27 1/16"(687) 18.59 (1.73) 6.01 (0.56) 3 1/4"**(83)**22.86 (2.12) 3626 2.91 (0.27) 38"(965) 11 1/16"(280) 6.79 (0.63) 2.91 (0.27) 48 15/16"(1243) 9.59 (0.89) 3630 3.70 (0.34) 38"(965) 14 1/16"(357) 8.32 (0.77) 3.70 (0.34) 42 15/16"(1091) 11.31 (1.05) 3636 4.50 (0.42) 38"(965) 17 1/16"(433) 9.84 (0.91) 4.50 (0.42) 36 15/16"(938) 13.04 (1.21) 3640 5.29 (0.49) 38"(965) 20 1/16"(509) 11.37 (1.06) 5.29 (0.49) 30 15/16"(786) 14.77 (1.37) 3646 6.08 (0.56) 38"(965) 23 1/16"(585) 12.89 (1.20) 6.08 (0.56) 24 15/16"(633) 16.50 (1.53) 3650 ◊6.87 (0.64) 38"(965) 26 1/16"(661) 14.42 (1.34) 6.87 (0.64) 18 15/16"(481) 18.23 (1.69) 3656 ◊7.66 (0.71) 38"(965) 29 1/16"(738) 15.95 (1.48) 7.66 (0.71) 12 15/16"(329) 19.96 (1.85) 3660 ◊8.45 (0.79) 38"(965) 32 1/16"(814) 17.47 (1.62) 8.45 (0.79) 6 15/16"(176) 21.69 (2.02) 3666 ◊9.25 (0.86) 38"(965) 35 1/16"(890) 19.00 (1.77) 9.25 (0.86) 14 7/16"**(367)**23.42 (2.18) 3670 ◊*6.61 (0.61) 38"(965) 25 1/16"(636) 20.77 (1.93) 6.61 (0.61) 8 7/16"**(214)**25.15 (2.34) 3676 ◊*7.14 (0.66) 38" (965) 27 1/16"(687) 22.32 (2.07) 7.14 (0.66) 2 7/16"**(62)**26.88 (2.50) (continued from page 33) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096) except for XX66, XX70 and XX76 heights, which are calculated using a header height of 8' (2438). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). *Available only with a 2:1 reverse cottage sash ratio. **Calculated based upon a structural header height of 8' (2438). • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096) except for XX70 and XX76 heights, which are calculated using a header height of 8' (2438). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). *Available only with a 2:1 reverse cottage sash ratio. **Calculated based upon a structural header height of 8' (2438). (continued from page 35) For reverse cottage, twin and triple single-hung window specifications, see pages 43, 45 and 47. continued on page 39 Single-Hung Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Height Inches/(mm) 3020 1.79 (0.17) 32" (813) 8 1/16"(204) 3.07 (0.29) 1.79 (0.17) 60 1/2"(1537) 5.79 (0.54) 3026 2.45 (0.23) 32" (813) 11 1/16"(280) 4.28 (0.40) 2.45 (0.23) 54 1/2"(1384) 7.27 (0.68) 3030 3.12 (0.29) 32" (813) 14 1/16"(357) 5.50 (0.51) 3.12 (0.29) 48 1/2"(1232) 8.75 (0.81) 3036 3.79 (0.35) 32" (813) 17 1/16"(433) 6.72 (0.62) 3.79 (0.35) 42 1/2"(1080) 10.23 (0.95) 3040 4.45 (0.41) 32" (813) 20 1/16"(509) 7.94 (0.74) 4.45 (0.41) 36 1/2"(927) 11.71 (1.09) 3046 5.12 (0.48) 32" (813) 23 1/16"(585) 9.16 (0.85) 5.12 (0.48) 30 1/2"(775) 13.19 (1.23) 3050 ◊5.79 (0.54) 32" (813) 26 1/16"(661) 10.38 (0.96) 5.79 (0.54) 24 1/2"(622) 14.67 (1.36) 3056 ◊6.45 (0.60) 32" (813) 29 1/16"(738) 11.60 (1.08) 6.45 (0.60) 18 1/2"(470) 16.15 (1.50) 3060 ◊7.12 (0.66) 32" (813) 32 1/16"(814) 12.82 (1.19) 7.12 (0.66) 12 1/2"(318) 17.63 (1.64) 3066 ◊7.79 (0.72) 32" (813) 35 1/16"(890) 14.03 (1.30) 7.79 (0.72) 6 1/2"(165) 19.11 (1.78) 3070*5.56 (0.52) 32" (813) 25 1/16"(636) 15.25 (1.42) 5.56 (0.52) 14"**(356)**20.59 (1.91) 3076 ◊*6.01 (0.56) 32" (813) 27 1/16"(687) 16.47 (1.53) 6.01 (0.56) 8"**(203)**22.06 (2.05) 3620 2.12 (0.20) 38" (965) 8 1/16"(204) 3.69 (0.34) 2.12 (0.20) 60 1/2"(1537) 6.77 (0.63) 3626 2.91 (0.27) 38" (965) 11 1/16"(280) 5.16 (0.48) 2.91 (0.27) 54 1/2"(1384) 8.50 (0.79) 3630 3.71 (0.34) 38" (965) 14 1/16"(357) 6.63 (0.62) 3.71 (0.34) 48 1/2"(1232) 10.23 (0.95) 3636 4.50 (0.42) 38" (965) 17 1/16"(433) 8.10 (0.75) 4.50 (0.42) 42 1/2"(1080) 11.96 (1.11) 3640 5.29 (0.49) 38" (965) 20 1/16"(509) 9.57 (0.89) 5.29 (0.49) 36 1/2"(927) 13.69 (1.27) 3646 6.08 (0.57) 38" (965) 23 1/16"(585) 11.04 (1.03) 6.08 (0.57) 30 1/2"(775) 15.42 (1.43) 3650 ◊6.87 (0.64) 38" (965) 26 1/16"(661) 12.51 (1.16) 6.87 (0.64) 24 1/2"(622) 17.15 (1.59) 3656 ◊7.66 (0.71) 38" (965) 29 1/16"(738) 13.98 (1.30) 7.66 (0.71) 18 1/2"(470) 18.88 (1.75) 3660 ◊8.46 (0.79) 38" (965) 32 1/16"(814) 15.44 (1.44) 8.46 (0.79) 12 1/2"(318) 20.61 (1.91) 3666 ◊9.25 (0.86) 38" (965) 35 1/16"(890) 16.91 (1.57) 9.25 (0.86) 6 1/2"(165) 22.34 (2.08) 3670 ◊*6.61 (0.61) 38" (965) 25 1/16"(636) 18.38 (1.71) 6.61 (0.61) 14"**(356)**24.06 (2.24) 3676 ◊*7.14 (0.66) 38" (965) 27 1/16"(687) 19.85 (1.84) 7.14 (0.66) 8"**(203)**25.79 (2.40) 4020 2.46 (0.23) 44" (1118) 8 1/16"(204) 4.32 (0.40) 2.46 (0.23) 60 1/2"(1537) 7.75 (0.72) 4026 3.37 (0.31) 44"(1118) 11 1/16"(280) 6.04 (0.56) 3.37 (0.31) 54 1/2"(1384) 9.73 (0.90) 4030 4.29 (0.40) 44"(1118) 14 1/16"(357) 7.76 (0.72) 4.29 (0.40) 48 1/2"(1232) 11.71 (1.09) 4036 5.21 (0.48) 44"(1118) 17 1/16"(433) 9.48 (0.88) 5.21 (0.48) 42 1/2"(1080) 13.69 (1.27) 4040 6.12 (0.57) 44"(1118) 20 1/16"(509) 11.20 (1.04) 6.12 (0.57) 36 1/2"(927) 15.67 (1.46) 4046 7.04 (0.65) 44"(1118) 23 1/16"(585) 12.92 (1.20) 7.04 (0.65) 30 1/2"(775) 17.65 (1.64) 4050 ◊7.96 (0.74) 44"(1118) 26 1/16"(661) 14.64 (1.36) 7.96 (0.74) 24 1/2"(622) 19.63 (1.82) 4056 ◊8.87 (0.82) 44"(1118) 29 1/16"(738) 16.35 (1.52) 8.87 (0.82) 18 1/2"(470) 21.61 (2.01) 4060 ◊9.79 (0.91) 44" (1118) 32 1/16"(814) 18.07 (1.68) 9.79 (0.91) 12 1/2"(318) 23.59 (2.19) 4066 ◊10.71 (1.00) 44"(1118) 35 1/16"(890) 19.79 (1.84) 10.70 (1.00) 6 1/2"(165) 25.56 (2.38) 4070 ◊*7.65 (0.71) 44"(1118) 25 1/16"(636) 21.51 (2.00) 7.65 (0.71) 14"**(356)**27.54 (2.56) 4076 ◊*8.26 (0.77) 44"(1118) 27 1/16"(687) 23.23 (2.16) 8.26 (0.77) 8"**(203)**29.52 (2.74) 41 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES 16-4640-16 16-5040-16 16-5640-1616-3040-16 16-4040-16 16-4646-16 16-5046-16 16-5646-1616-3046-16 16-4046-16 16-4650-16 16-5050-16 16-5650-1616-3050-16 16-4050-16 16-4656-16 16-5056-16 16-5656-1616-3056-16 16-4056-16 16-4660-16 16-5060-16 16-5660-1616-3060-16 16-4060-16 16-4610-16 16-5010-16 16-5610-1616-3010-16 16-4010-16 16-4616-16 16-5016-16 16-5616-1616-3016-16 16-4016-16 16-4620-16 16-5020-16 16-5620-1616-3020-16 16-4020-16 16-3640-16 16-3646-16 16-3650-16 16-3656-16 16-3660-16 16-3610-16 16-3616-16 16-3620-16 Window Dimension Unobstructed Glass (center sash only) Minimum Rough Opening Table of Picture Window With Flanking 16-Wide Single-Hungs Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 6'-0" 5'-11 1/2" 29 1/4"35 1/4" 6'-5 1/2" 6'-6" 41 1/4" 6'-11 1/2" 7'-0" 47 1/4" 7'-5 1/2" 7'-6" 53 1/4" 7'-11 1/2" 8'-0" 59 1/4" 8'-5 1/2" 8'-6" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" (1816) (1829) (743) (1969) (1981) (895) (2121) (2134) (1048) (2273) (2286) (1200) (2426) (2438) (1353) (2578) (2591) (1505) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) Windows have one continuous outer frame. Unobstructed glass width dimension of flanking sash is 11 1 ⁄4" (286). For unobstructed glass height dimensions of flanking single-hungs, see page 34. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 49. Details shown on pages 52-54. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. 42 SINGLE-HUNG WINDOWS 16-6040-16 16-6046-16 16-6050-16 16-6056-16 16-6060-16 16-6010-16 16-6016-16 16-6020-16 65 1/4" 8'-11 1/2" 9'-0" (2731) (2743) (1657) See notes on previous page. Single-Hung Window Opening and Area Specifications – 3:2 Reverse Cottage Sash Ratio Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 1626 0.88 (0.08) 14"(356) 9 1/16"(230) 1.65 (0.15) 0.88 (0.08) 54 1/2"(1384) 3.59 (0.33) 1630 1.07 (0.10) 14"(356) 11 1/16"(280) 2.12 (0.20) 1.07 (0.10) 48 1/2"(1232) 4.31 (0.40) 1636 1.37 (0.13) 14"(356) 14 1/16"(357) 2.59 (0.24) 1.37 (0.13) 42 1/2"(1080) 5.04 (0.47) 1640 1.56 (0.15) 14"(356) 16 1/16"(407) 3.05 (0.28) 1.56 (0.15) 36 1/2"(927) 5.77 (0.54) 1646 1.85 (0.17) 14"(356) 19 1/16"(484) 3.52 (0.33) 1.85 (0.17) 30 1/2"(775) 6.50 (0.60) 1650 2.05 (0.19) 14"(356) 21 1/16"(534) 3.99 (0.37) 2.05 (0.19) 24 1/2"(622) 7.23 (0.67) 1656 2.24 (0.21) 14"(356) 23 1/16"(585) 4.46 (0.41) 2.24 (0.21) 18 1/2"(470) 7.96 (0.74) 1660 2.53 (0.24) 14"(356) 26 1/16"(661) 4.93 (0.46) 2.53 (0.24) 12 1/2"(318) 8.69 (0.81) 1666 2.73 (0.25) 14"(356) 28 1/16"(712) 5.40 (0.50) 2.73 (0.25) 6 1/2"(165) 9.42 (0.88) 2026 1.26 (0.12) 20"(508) 9 1/16"(230) 2.53 (0.24) 1.26 (0.12) 54 1/2"(1384) 4.81 (0.45) 2030 1.53 (0.14) 20"(508) 11 1/16"(280) 3.25 (0.30) 1.53 (0.14) 48 1/2"(1232) 5.79 (0.54) 2036 1.95 (0.18) 20"(508) 14 1/16"(357) 3.96 (0.37) 1.95 (0.18) 42 1/2"(1080) 6.77 (0.63) 2040 2.23 (0.21) 20"(508) 16 1/16"(407) 4.68 (0.44) 2.23 (0.21) 36 1/2"(927) 7.75 (0.72) 2046 2.64 (0.25) 20"(508) 19 1/16"(484) 5.40 (0.50) 2.64 (0.25) 30 1/2"(775) 8.73 (0.81) 2050 2.92 (0.27) 20"(508) 21 1/16"(534) 6.12 (0.57) 2.92 (0.27) 24 1/2"(622) 9.71 (0.90) 2056 3.20 (0.30) 20"(508) 23 1/16"(585) 6.84 (0.64) 3.20 (0.30) 18 1/2"(470) 10.69 (0.99) 2060 3.62 (0.34) 20"(508) 26 1/16"(661) 7.56 (0.70) 3.62 (0.34) 12 1/2"(318) 11.67 (1.08) 2066 3.89 (0.36) 20"(508) 28 1/16"(712) 8.28 (0.77) 3.89 (0.36) 6 1/2"(165) 12.65 (1.18) 2626 1.63 (0.15) 26"(660) 9 1/16"(230) 3.41 (0.32) 1.63 (0.15) 54 1/2"(1384) 6.04 (0.56) 2630 1.99 (0.19) 26"(660) 11 1/16"(280) 4.37 (0.41) 1.99 (0.19) 48 1/2"(1232) 7.27 (0.68) 2636 2.54 (0.24) 26"(660) 14 1/16"(357) 5.34 (0.50) 2.54 (0.24) 42 1/2"(1080) 8.50 (0.79) 2640 2.90 (0.27) 26"(660) 16 1/16"(407) 6.31 (0.59) 2.90 (0.27) 36 1/2"(927) 9.73 (0.90) 2646 3.44 (0.32) 26"(660) 19 1/16"(484) 7.28 (0.68) 3.44 (0.32) 30 1/2"(775) 10.96 (1.02) 2650 3.80 (0.35) 26"(660) 21 1/16"(534) 8.25 (0.77) 3.80 (0.35) 24 1/2"(622) 12.19 (1.13) 2656 4.16 (0.39) 26"(660) 23 1/16"(585) 9.22 (0.86) 4.16 (0.39) 18 1/2"(470) 13.42 (1.25) 2660 4.70 (0.44) 26"(660) 26 1/16"(661) 10.19 (0.95) 4.70 (0.44) 12 1/2"(318) 14.65 (1.36) 2666 5.06 (0.47) 26"(660) 28 1/16"(712) 11.16 (1.04) 5.06 (0.47) 6 1/2"(165) 15.88 (1.48) 3026 2.01 (0.19) 32"(813) 9 1/16"(230) 4.28 (0.40) 2.01 (0.19) 54 1/2"(1384) 7.27 (0.68) 3030 2.45 (0.23) 32"(813) 11 1/16"(280) 5.50 (0.51) 2.45 (0.23) 48 1/2"(1232) 8.75 (0.81) 3036 3.12 (0.29) 32"(813) 14 1/16"(357) 6.72 (0.62) 3.12 (0.29) 42 1/2"(1080) 10.23 (0.95) 3040 3.56 (0.33) 32"(813) 16 1/16"(407) 7.94 (0.74) 3.56 (0.33) 36 1/2"(927) 11.71 (1.09) 3046 4.23 (0.39) 32"(813) 19 1/16"(484) 9.16 (0.85) 4.23 (0.39) 30 1/2"(775) 13.19 (1.23) 3050 4.68 (0.43) 32"(813) 21 1/16"(534) 10.38 (0.96) 4.68 (0.43) 24 1/2"(622) 14.67 (1.36) 3056 5.12 (0.48) 32"(813) 23 1/16"(585) 11.60 (1.08) 5.12 (0.48) 18 1/2"(470) 16.15 (1.50) 3060 ◊5.79 (0.54) 32"(813) 26 1/16"(661) 12.82 (1.19) 5.79 (0.54) 12 1/2"(318) 17.63 (1.64) 3066 ◊6.23 (0.58) 32"(813) 28 1/16"(712) 14.03 (1.30) 6.23 (0.58) 6 1/2"(165) 19.11 (1.78) 3626 2.39 (0.22) 38"(965) 9 1/16"(230) 5.16 (0.48) 2.39 (0.22) 54 1/2"(1384) 8.50 (0.79) 3630 2.91 (0.27) 38"(965) 11 1/16"(280) 6.63 (0.62) 2.91 (0.27) 48 1/2"(1232) 10.23 (0.95) 3636 3.71 (0.34) 38"(965) 14 1/16"(357) 8.10 (0.75) 3.71 (0.34) 42 1/2"(1080) 11.96 (1.11) 3640 4.23 (0.39) 38"(965) 16 1/16"(407) 9.57 (0.89) 4.23 (0.39) 36 1/2"(927) 13.69 (1.27) 3646 5.02 (0.47) 38"(965) 19 1/16"(484) 11.04 (1.03) 5.02 (0.47) 30 1/2"(775) 15.42 (1.43) 3650 5.55 (0.52) 38"(965) 21 1/16"(534) 12.51 (1.16) 5.55 (0.52) 24 1/2"(622) 17.15 (1.59) 3656 6.08 (0.57) 38"(965) 23 1/16"(585) 13.98 (1.30) 6.08 (0.57) 18 1/2"(470) 18.88 (1.75) 3660 ◊6.87 (0.64) 38"(965) 26 1/16"(661) 15.44 (1.44) 6.87 (0.64) 12 1/2"(318) 20.61 (1.91) 3666 ◊7.40 (0.69) 38"(965) 28 1/16"(712) 16.91 (1.57) 7.40 (0.69) 6 1/2"(165) 22.34 (2.08) 4026 2.76 (0.26) 44"(1118) 9 1/16"(230) 6.04 (0.56) 2.76 (0.26) 54 1/2"(1384) 9.73 (0.90) 4030 3.37 (0.31) 44"(1118) 11 1/16"(280) 7.76 (0.72) 3.37 (0.31) 48 1/2"(1232) 11.71 (1.09) 4036 4.29 (0.40) 44"(1118) 14 1/16"(357) 9.48 (0.88) 4.29 (0.40) 42 1/2"(1080) 13.69 (1.27) 4040 4.90 (0.46) 44"(1118) 16 1/16"(407) 11.20 (1.04) 4.90 (0.46) 36 1/2"(927) 15.67 (1.46) 4046 5.82 (0.54) 44"(1118) 19 1/16"(484) 12.92 (1.20) 5.82 (0.54) 30 1/2"(775) 17.65 (1.64) 4050 6.43 (0.60) 44"(1118) 21 1/16"(534) 14.64 (1.36) 6.43 (0.60) 24 1/2"(622) 19.63 (1.82) 4056 7.04 (0.65) 44"(1118) 23 1/16"(585) 16.35 (1.52) 7.04 (0.65) 18 1/2"(470) 21.61 (2.01) 4060 ◊7.96 (0.74) 44"(1118) 26 1/16"(661) 18.07 (1.68) 7.96 (0.74) 12 1/2"(318) 23.59 (2.19) 4066 ◊8.57 (0.80) 44"(1118) 28 1/16"(712) 19.79 (1.84) 8.57 (0.80) 6 1/2"(165) 25.56 (2.38) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 43 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Windows have one continuous outer frame. Unobstructed glass width dimension of flanking sash is 17 1 ⁄4" (438). For unobstructed glass height dimensions of flanking single-hungs, see page 34. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 49. Details shown on pages 52-54. 20-4640-20 20-5040-2020-3040-20 20-4040-20 20-4646-20 20-5046-2020-3046-20 20-4046-20 20-4650-20 20-5050-2020-3050-20 20-4050-20 20-4656-20 20-5056-2020-3056-20 20-4056-20 20-4660-20 20-5060-2020-3060-20 20-4060-20 20-4610-20 20-5010-2020-3010-20 20-4010-20 20-4616-20 20-5016-2020-3016-20 20-4016-20 20-4620-20 20-5020-2020-3020-20 20-4020-20 20-3640-20 20-3646-20 20-3650-20 20-3656-20 20-3660-20 20-3610-20 20-3616-20 20-3620-20 Window Dimension Unobstructed Glass (center sash only) Minimum Rough Opening Table of Picture Window With Flanking 20-Wide Single-Hungs Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 29 1/4" 6'-11 1/2" 7'-0" 35 1/4" 7'-5 1/2" 7'-6" 41 1/4" 7'-11 1/2" 8'-0" 47 1/4" 8'-5 1/2" 8'-6" 53 1/4" 8'-11 1/2" 9'-0" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" (2121) (2134) (743) (2273) (2286) (895) (2426) (2438) (1048) (2578) (2591) (1200) (2731) (2743) (1353) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) 44 SINGLE-HUNG WINDOWS 20-5640-20 20-5646-20 20-5650-20 20-5656-20 20-5660-20 20-6040-20 20-6046-20 20-6050-20 20-6056-20 20-6060-20 20-5610-20 20-6010-20 20-5616-20 20-6016-20 20-5620-20 20-6020-20 59 1/4" 9'-5 1/2" 9'-6" 65 1/4" 9'-11 1/2" 10'-0" (2883) (2896) (1505) (3035) (3048) (1657) Notes on previous page also apply to this page. Twin Single-Hung Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Height Inches/(mm) 1620-2 0.78 (0.07) 14"(356) 8 1/16"(204) 2.36 (0.22) 1.56 (0.15) 60 1/2"(1537) 5.79 (0.54) 1626-2 1.07 (0.10) 14"(356) 11 1/16"(280) 3.30 (0.31) 2.15 (0.20) 54 1/2"(1384) 7.27 (0.68) 1630-2 1.37 (0.13) 14"(356) 14 1/16"(357) 4.23 (0.39) 2.73 (0.25) 48 1/2"(1232) 8.75 (0.81) 1636-2 1.66 (0.15) 14"(356) 17 1/16"(433) 5.17 (0.48) 3.31 (0.31) 42 1/2"(1080) 10.23 (0.95) 1640-2 1.95 (0.18) 14"(356) 20 1/16"(509) 6.11 (0.57) 3.90 (0.36) 36 1/2"(927) 11.71 (1.09) 1646-2 2.24 (0.21) 14"(356) 23 1/16"(585) 7.05 (0.66) 4.48 (0.42) 30 1/2"(775) 13.19 (1.23) 1650-2 2.53 (0.24) 14"(356) 26 1/16"(661) 7.98 (0.74) 5.06 (0.47) 24 1/2"(622) 14.67 (1.36) 1656-2 2.82 (0.26) 14"(356) 29 1/16"(738) 8.92 (0.83) 5.65 (0.53) 18 1/2"(470) 16.15 (1.50) 1660-2 3.12 (0.29) 14"(356) 32 1/16"(814) 9.86 (0.92) 6.23 (0.58) 12 1/2"(318) 17.63 (1.64) 2020-2 1.12 (0.10) 20"(508) 8 1/16"(204) 3.62 (0.34) 2.23 (0.21) 60 1/2"(1537) 7.75 (0.72) 2026-2 1.53 (0.14) 20"(508) 11 1/16"(280) 5.05 (0.47) 3.07 (0.29) 54 1/2"(1384) 9.73 (0.90) 2030-2 1.95 (0.18) 20"(508) 14 1/16"(357) 6.49 (0.60) 3.90 (0.36) 48 1/2"(1232) 11.71 (1.09) 2036-2 2.37 (0.22) 20"(508) 17 1/16"(433) 7.93 (0.74) 4.73 (0.44) 42 1/2"(1080) 13.69 (1.27) 2040-2 2.78 (0.26) 20"(508) 20 1/16"(509) 9.37 (0.87) 5.57 (0.52) 36 1/2"(927) 15.67 (1.46) 2046-2 3.20 (0.30) 20"(508) 23 1/16"(585) 10.80 (1.00) 6.40 (0.60) 30 1/2"(775) 17.65 (1.64) 2050-2 3.62 (0.34) 20"(508) 26 1/16"(661) 12.24 (1.14) 7.23 (0.67) 24 1/2"(622) 19.63 (1.82) 2056-2 4.03 (0.38) 20"(508) 29 1/16"(738) 13.68 (1.27) 8.07 (0.75) 18 1/2"(470) 21.61 (2.01) 2060-2 4.45 (0.41) 20"(508) 32 1/16"(814) 15.12 (1.40) 8.90 (0.83) 12 1/2"(318) 23.59 (2.19) 2620-2 1.45 (0.14) 26"(660) 8 1/16"(204) 4.87 (0.45) 2.90 (0.27) 60 1/2"(1537) 9.71 (0.90) 2626-2 1.99 (0.19) 26"(660) 11 1/16"(280) 6.81 (0.63) 3.99 (0.37) 54 1/2"(1384) 12.19 (1.13) 2630-2 2.54 (0.24) 26"(660) 14 1/16"(357) 8.75 (0.81) 5.07 (0.47) 48 1/2"(1232) 14.67 (1.36) 2636-2 3.08 (0.29) 26"(660) 17 1/16"(433) 10.69 (0.99) 6.15 (0.57) 42 1/2"(1080) 17.15 (1.59) 2640-2 3.62 (0.34) 26"(660) 20 1/16"(509) 12.62 (1.17) 7.24 (0.67) 36 1/2"(927) 19.63 (1.82) 2646-2 4.16 (0.39) 26"(660) 23 1/16"(585) 14.56 (1.35) 8.32 (0.77) 30 1/2"(775) 22.11 (2.05) 2650-2 4.70 (0.44) 26"(660) 26 1/16"(661) 16.50 (1.53) 9.40 (0.87) 24 1/2"(622) 24.59 (2.28) 2656-2 5.24 (0.49) 26"(660) 29 1/16"(738) 18.44 (1.71) 10.49 (0.97) 18 1/2"(470) 27.06 (2.51) 2660-2 ◊5.79 (0.54) 26" (660) 32 1/16"(814) 20.37 (1.89) 11.57 (1.08) 12 1/2"(318) 29.54 (2.75) 3020-2 1.79 (0.17) 32" (813) 8 1/16"(204) 6.13 (0.57) 3.57 (0.33) 60 1/2"(1537) 11.67 (1.08) 3026-2 2.45 (0.23) 32" (813) 11 1/16"(280) 8.57 (0.80) 4.91 (0.46) 54 1/2"(1384) 14.65 (1.36) 3030-2 3.12 (0.29) 32"(813) 14 1/16"(357) 11.01 (1.02) 6.24 (0.58) 48 1/2"(1232) 17.63 (1.64) 3036-2 3.79 (0.35) 32" (813) 17 1/16"(433) 13.44 (1.25) 7.57 (0.70) 42 1/2"(1080) 20.61 (1.91) 3040-2 4.45 (0.41) 32" (813) 20 1/16"(509) 15.88 (1.48) 8.91 (0.83) 36 1/2"(927) 23.59 (2.19) 3046-2 5.12 (0.48) 32" (813) 23 1/16"(585) 18.32 (1.70) 10.24 (0.95) 30 1/2"(775) 26.56 (2.47) 3050-2 ◊5.79 (0.54) 32"(813) 26 1/16"(661) 20.76 (1.93) 11.57 (1.08) 24 1/2"(622) 29.54 (2.75) 3056-2 ◊6.45 (0.60) 32" (813) 29 1/16"(738) 23.19 (2.16) 12.91 (1.20) 18 1/2"(470) 32.52 (3.02) 3060-2 ◊7.12 (0.66) 32" (813) 32 1/16"(814) 25.63 (2.38) 14.24 (1.32) 12 1/2"(318) 35.50 (3.30) 3620-2 2.12 (0.20) 38" (965) 8 1/16"(204) 7.39 (0.69) 4.24 (0.39) 60 1/2"(1537) 13.63 (1.27) 3626-2 2.91 (0.27) 38" (965) 11 1/16"(280) 10.33 (0.96) 5.83 (0.54) 54 1/2"(1384) 17.11 (1.59) 3630-2 3.71 (0.34) 38" (965) 14 1/16"(357) 13.26 (1.23) 7.41 (0.69) 48 1/2"(1232) 20.59 (1.91) 3636-2 4.50 (0.42) 38" (965) 17 1/16"(433) 16.20 (1.51) 8.99 (0.84) 42 1/2"(1080) 24.06 (2.24) 3640-2 5.29 (0.49) 38" (965) 20 1/16"(509) 19.14 (1.78) 10.58 (0.98) 36 1/2"(927) 27.54 (2.56) 3646-2 6.08 (0.57) 38" (965) 23 1/16"(585) 22.08 (2.05) 12.16 (1.13) 30 1/2"(775) 31.02 (2.88) 3650-2 ◊6.87 (0.64) 38" (965) 26 1/16"(661) 25.01 (2.32) 13.74 (1.28) 24 1/2"(622) 34.50 (3.21) 3656-2 ◊7.66 (0.71) 38"(965) 29 1/16"(738) 27.95 (2.60) 15.33 (1.42) 18 1/2"(470) 37.98 (3.53) 3660-2 ◊8.46 (0.79) 38"(965) 32 1/16"(814) 30.89 (2.87) 16.91 (1.57) 12 1/2"(318) 41.46 (3.85) 4020-2 2.46 (0.23) 44"(1118) 8 1/16"(204) 8.65 (0.80) 4.91 (0.46) 60 1/2"(1537) 15.59 (1.45) 4026-2 3.37 (0.31) 44" (1118) 11 1/16"(280) 12.08 (1.12) 6.75 (0.63) 54 1/2"(1384) 19.56 (1.82) 4030-2 4.29 (0.40) 44" (1118) 14 1/16"(357) 15.52 (1.44) 8.58 (0.80) 48 1/2"(1232) 23.54 (2.19) 4036-2 5.21 (0.48) 44" (1118) 17 1/16"(433) 18.96 (1.76) 10.41 (0.97) 42 1/2"(1080) 27.52 (2.56) 4040-2 6.12 (0.57) 44"(1118) 20 1/16"(509) 22.40 (2.08) 12.25 (1.14) 36 1/2"(927) 31.50 (2.93) 4046-2 7.04 (0.65) 44"(1118) 23 1/16"(585) 25.83 (2.40) 14.08 (1.31) 30 1/2"(775) 35.48 (3.30) 4050-2 ◊7.96 (0.74) 44" (1118) 26 1/16"(661) 29.27 (2.72) 15.91 (1.48) 24 1/2"(622) 39.46 (3.67) 4056-2 ◊8.87 (0.82) 44"(1118) 29 1/16"(738) 32.71 (3.04) 17.75 (1.65) 18 1/2"(470) 43.44 (4.04) 4060-2 ◊9.79 (0.91) 44" (1118) 32 1/16"(814) 36.15 (3.36) 19.58 (1.82) 12 1/2"(318) 47.42 (4.41) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 45 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES Windows have one continuous outer frame. Unobstructed glass width dimension of flanking sash is 23 1 ⁄4" (591). For unobstructed glass height dimensions of flanking single-hungs, see page 34. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown on page 49. Details shown on pages 52-54. 26-4640-26 26-5040-2626-3040-26 26-4040-26 26-4646-26 26-5046-2626-3046-26 26-4046-26 26-4650-26 26-5050-2626-3050-26 26-4050-26 26-4656-26 26-5056-2626-3056-26 26-4056-26 26-4660-26 26-5060-2626-3060-26 26-4060-26 26-4610-26 26-5010-2626-3010-26 26-4010-26 26-4616-26 26-5016-2626-3016-26 26-4016-26 26-4620-26 26-5020-2626-3020-26 26-4020-26 26-3640-26 26-3646-26 26-3650-26 26-3656-26 26-3660-26 26-3610-26 26-3616-26 26-3620-26 Window Dimension Unobstructed Glass (center sash only) Minimum Rough Opening Table of Picture Window With Flanking 26-Wide Single-Hungs Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 29 1/4" 7'-11 1/2" 8'-0" 35 1/4" 8'-5 1/2" 8'-6" 41 1/4" 8'-11 1/2" 9'-0" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 47 1/4" 9'-5 1/2" 9'-6" 53 1/4" 9'-11 1/2" 10'-0" (2426) (2438) (743) (2578) (2591) (895) (2731) (2743) (1048) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (2883) (2896) (1200) (3035) (3048) (1353) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 46 SINGLE-HUNG WINDOWS 26-5640-26 26-5646-26 26-5650-26 26-5656-26 26-5660-26 26-6040-26 26-6046-26 26-6050-26 26-6056-26 26-6060-26 26-5610-26 26-6010-26 26-5616-26 26-6016-26 26-5620-26 26-6020-26 59 1/4" 10'-5 1/2" 10'-6" 65 1/4" 10'-11 1/2" 11'-0" (3188) (3200) (1505) (3340) (3353) (1657) Notes on previous page also apply to this page. Triple Single-Hung Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 1620-3 0.78 (0.07) 14"(356) 8 1/16"(204) 3.54 (0.33) 2.35 (0.22) 60 1/2"(1537) 8.73 (0.81) 1626-3 1.07 (0.10) 14"(356) 11 1/16"(280) 4.94 (0.46) 3.22 (0.30) 54 1/2"(1384) 10.96 (1.02) 1630-3 1.37 (0.13) 14"(356) 14 1/16"(357) 6.35 (0.59) 4.10 (0.38) 48 1/2"(1232) 13.19 (1.23) 1636-3 1.66 (0.15) 14"(356) 17 1/16"(433) 7.76 (0.72) 4.97 (0.46) 42 1/2"(1080) 15.42 (1.43) 1640-3 1.95 (0.18) 14"(356) 20 1/16"(509) 9.16 (0.85) 5.85 (0.54) 36 1/2"(927) 17.65 (1.64) 1646-3 2.24 (0.21) 14"(356) 23 1/16"(585) 10.57 (0.98) 6.72 (0.62) 30 1/2"(775) 19.88 (1.85) 1650-3 2.53 (0.24) 14"(356) 26 1/16"(661) 11.97 (1.11) 7.60 (0.71) 24 1/2"(622) 22.11 (2.05) 1656-3 2.82 (0.26) 14"(356) 29 1/16"(738) 13.38 (1.24) 8.47 (0.79) 18 1/2"(470) 24.34 (2.26) 1660-3 3.12 (0.29) 14"(356) 32 1/16"(814) 14.79 (1.37) 9.35 (0.87) 12 1/2"(318) 26.56 (2.47) 2020-3 1.12 (0.10) 20"(508) 8 1/16"(204) 5.42 (0.50) 3.35 (0.31) 60 1/2"(1537) 11.67 (1.08) 2026-3 1.53 (0.14) 20"(508) 11 1/16"(280) 7.58 (0.70) 4.60 (0.43) 54 1/2"(1384) 14.65 (1.36) 2030-3 1.95 (0.18) 20"(508) 14 1/16"(357) 9.74 (0.90) 5.85 (0.54) 48 1/2"(1232) 17.63 (1.64) 2036-3 2.37 (0.22) 20"(508) 17 1/16"(433) 11.89 (1.11) 7.10 (0.66) 42 1/2"(1080) 20.61 (1.91) 2040-3 2.78 (0.26) 20"(508) 20 1/16"(509) 14.05 (1.31) 8.35 (0.78) 36 1/2"(927) 23.59 (2.19) 2046-3 3.20 (0.30) 20"(508) 23 1/16"(585) 16.20 (1.51) 9.60 (0.89) 30 1/2"(775) 26.56 (2.47) 2050-3 3.62 (0.34) 20"(508) 26 1/16"(661) 18.36 (1.71) 10.85 (1.01) 24 1/2"(622) 29.54 (2.75) 2056-3 4.03 (0.38) 20"(508) 29 1/16"(738) 20.52 (1.91) 12.10 (1.12) 18 1/2"(470) 32.52 (3.02) 2060-3 4.45 (0.41) 20"(508) 32 1/16"(814) 22.67 (2.11) 13.35 (1.24) 12 1/2"(318) 35.50 (3.30) 2620-3 1.45 (0.14) 26"(660) 8 1/16"(204) 7.31 (0.68) 4.35 (0.41) 60 1/2"(1537) 14.61 (1.36) 2626-3 1.99 (0.19) 26"(660) 11 1/16"(280) 10.22 (0.95) 5.98 (0.56) 54 1/2"(1384) 18.34 (1.70) 2630-3 2.54 (0.24) 26"(660) 14 1/16"(357) 13.12 (1.22) 7.60 (0.71) 48 1/2"(1232) 22.06 (2.05) 2636-3 3.08 (0.29) 26"(660) 17 1/16"(433) 16.03 (1.49) 9.23 (0.86) 42 1/2"(1080) 25.79 (2.40) 2640-3 3.62 (0.34) 26"(660) 20 1/16"(509) 18.93 (1.76) 10.85 (1.01) 36 1/2"(927) 29.52 (2.74) 2646-3 4.16 (0.39) 26"(660) 23 1/16"(585) 21.84 (2.03) 12.48 (1.16) 30 1/2"(775) 33.25 (3.09) 2650-3 4.70 (0.44) 26"(660) 26 1/16"(661) 24.75 (2.30) 14.10 (1.31) 24 1/2"(622) 36.98 (3.44) 2656-3 5.24 (0.49) 26"(660) 29 1/16"(738) 27.65 (2.57) 15.73 (1.46) 18 1/2"(470) 40.71 (3.78) 2660-3 ◊5.79 (0.54) 26"(660) 32 1/16"(814) 30.56 (2.84) 17.35 (1.61) 12 1/2"(318) 44.44 (4.13) 3020-3 1.79 (0.17) 32" (813) 8 1/16"(204) 9.20 (0.85) 5.36 (0.50) 60 1/2"(1537) 17.54 (1.63) 3026-3 2.45 (0.23) 32" (813) 11 1/16"(280) 12.85 (1.19) 7.36 (0.68) 54 1/2"(1384) 22.02 (2.05) 3030-3 3.12 (0.29) 32" (813) 14 1/16"(357) 16.51 (1.53) 9.36 (0.87) 48 1/2"(1232) 26.50 (2.46) 3036-3 3.79 (0.35) 32" (813) 17 1/16"(433) 20.16 (1.87) 11.36 (1.06) 42 1/2"(1080) 30.98 (2.88) 3040-3 4.45 (0.41) 32" (813) 20 1/16"(509) 23.82 (2.21) 13.36 (1.24) 36 1/2"(927) 35.46 (3.29) 3046-3 5.12 (0.48) 32" (813) 23 1/16"(585) 27.48 (2.55) 15.36 (1.43) 30 1/2"(775) 39.94 (3.71) 3050-3 ◊5.79 (0.54) 32" (813) 26 1/16"(661) 31.13 (2.89) 17.36 (1.61) 24 1/2"(622) 44.42 (4.13) 3056-3 ◊6.45 (0.60) 32" (813) 29 1/16"(738) 34.79 (3.23) 19.36 (1.80) 18 1/2"(470) 48.90 (4.54) 3060-3 ◊7.12 (0.66) 32" (813) 32 1/2"(814) 38.45 (3.57) 21.36 (1.98) 12 1/2"(318) 53.38 (4.96) 3620-3 2.12 (0.20) 38"(965) 8 1/16"(204) 11.08 (1.03) 6.36 (0.59) 60 1/2"(1537) 20.48 (1.90) 3626-3 2.91 (0.27) 38"(965) 11 1/16"(280) 15.49 (1.44) 8.74 (0.81) 54 1/2"(1384) 25.71 (2.39) 3630-3 3.71 (0.34) 38"(965) 14 1/16"(357) 19.89 (1.85) 11.11 (1.03) 48 1/2"(1232) 30.94 (2.87) 3636-3 4.50 (0.42) 38"(965) 17 1/16"(433) 24.30 (2.26) 13.49 (1.25) 42 1/2"(1080) 36.17 (3.36) 3640-3 5.29 (0.49) 38"(965) 20 1/16"(509) 28.71 (2.67) 15.86 (1.47) 36 1/2"(927) 41.40 (3.85) 3646-3 6.08 (0.57) 38"(965) 23 1/16"(585) 33.11 (3.08) 18.24 (1.69) 30 1/2"(775) 46.63 (4.33) 3650-3 ◊6.87 (0.64) 38"(965) 26 1/16"(661) 37.52 (3.49) 20.61 (1.92) 24 1/2"(622) 51.86 (4.82) 3656-3 ◊7.66 (0.71) 38"(965) 29 1/16"(738) 41.93 (3.90) 22.99 (2.14) 18 1/2"(470) 57.09 (5.30) 3660-3 ◊8.46 (0.79) 38"(965) 32 1/16"(814) 46.33 (4.30) 25.36 (2.36) 12 1/2"(318) 62.31 (5.79) 4020-3 2.46 (0.23) 44"(1118) 8 1/16"(204) 12.97 (1.21) 7.37 (0.69) 60 1/2"(1537) 23.42 (2.18) 4026-3 3.37 (0.31) 44"(1118) 11 1/16"(280) 18.12 (1.68) 10.12 (0.94) 54 1/2"(1384) 29.40 (2.73) 4030-3 4.29 (0.40) 44"(1118) 14 1/16"(357) 23.28 (2.16) 12.87 (1.20) 48 1/2"(1232) 35.38 (3.29) 4036-3 5.21 (0.48) 44"(1118) 17 1/16"(433) 28.44 (2.64) 15.62 (1.45) 42 1/2"(1080) 41.36 (3.84) 4040-3 6.12 (0.57) 44"(1118) 20 1/16"(509) 33.59 (3.12) 18.37 (1.71) 36 1/2"(927) 47.34 (4.40) 4046-3 7.04 (0.65) 44"(1118) 23 1/16"(585) 38.75 (3.60) 21.12 (1.96) 30 1/2"(775) 53.31 (4.95) 4050-3 ◊7.96 (0.74) 44"(1118) 26 1/16"(661) 43.91 (4.08) 23.87 (2.22) 24 1/2"(622) 59.29 (5.51) 4056-3 ◊8.87 (0.82) 44"(1118) 29 1/16"(738) 49.06 (4.56) 26.62 (2.47) 18 1/2"(470) 65.27 (6.06) 4060-3 ◊9.79 (0.91) 44"(1118) 32 1/16"(814) 54.22 (5.04) 29.37 (2.73) 12 1/2"(318) 71.25 (6.62) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 47 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES 30-4640-3030-3040-30 30-4040-30 30-4646-3030-3046-30 30-4046-30 30-4650-3030-3050-30 30-4050-30 30-4656-3030-3056-30 30-4056-30 30-4660-3030-3060-30 30-4060-30 30-4610-3030-3010-30 30-4010-30 30-4616-3030-3016-30 30-4016-30 30-4620-3030-3020-30 30-4020-30 30-3640-30 30-3646-30 30-3650-30 30-3656-30 30-3660-30 30-3610-30 30-3616-30 30-3620-30 Window Dimension Unobstructed Glass (center sash only) Minimum Rough Opening Table of Picture Window With Flanking 30-Wide Single-Hungs Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 29 1/4" 8'-11 1/2" 9'-0" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 35 1/4" 9'-5 1/2" 9'-6" 41 1/4" 9'-11 1/2" 10'-0" 47 1/4" 10'-5 1/2" 10'-6" (2731) (2743) (743) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (2883) (2896) (895) (3035) (3048) (1048) (3188) (3200) (1200) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Notes on next page also apply to this page. 48 SINGLE-HUNG WINDOWS Windows have one continuous outer frame. Unobstructed glass width dimension of flanking sash is 29 1 ⁄4" (743). For unobstructed glass height dimensions of flanking single-hungs, see page 34. Matching transom windows are also shown. See Picture, Transom & Specialty Windows section starting on page 68 for more information. Grille patterns shown below. Details shown on pages 52-54. 30-5040-30 30-5640-30 30-5046-30 30-5646-30 30-5050-30 30-5650-30 30-5056-30 30-5656-30 30-5060-30 30-5660-30 30-6040-30 30-6046-30 30-6050-30 30-6056-30 30-6060-30 30-5010-30 30-5610-30 30-6010-30 30-5016-30 30-5616-30 30-6016-30 30-5020-30 30-5620-30 30-6020-30 53 1/4" 10'-11 1/2" 11'-0" 59 1/4" 11'-5 1/2" 11'-6" 65 1/4" 11'-11 1/2" 12'-0" (3340) (3353) (1353) (3493) (3505) (1505) (3645) (3658) (1657) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Specied Equal Light Examples Custom Example*Custom Single-hung window patterns are also available in Upper Sash Only (USO) configurations. For picture window patterns that require alignment with single-hung patterns, identify the single-hung sash style (equal or reverse cottage) when ordering. Number of lights and overall pattern varies with window size. Patterns may not be available in all configurations or sizes. Specified equal light and custom grille patterns are also available. For specified equal light, specify number of same-size rectangles across or down. For more grille options, see page 14 or visit andersenwindows.com/grilles. Prairie A Colonial Fractional Short Single-Hung Grille Patterns *Grille illustration reflects a window taller than 6'-5 1/2" (1969) with a 2:1 sash ratio. • Dimensions in parentheses are in millimeters. 49 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES 1 3 ⁄4" (4 4 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d Gl a s s 1 5 ⁄16" (33) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄16 " (5 6 ) Low-E Glass Insect Screen sill head meeting rail Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening 1 7 ⁄16" (37) Arch Single-Hung Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Arch Single-Hung Vertical Section Arch Single-Hung, Stucco Exterior Horizontal Section Arch Single-Hung, Stucco Exterior Horizontal Section Arch Single-Hung 1 3 ⁄4" (4 4 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d Gl a s s 1" (25) 3 1 ⁄4" (83) 3 1 ⁄ 8" (7 9 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄16 " (5 6 ) 1 ⁄4" (6 ) 1 ⁄ 8" (3 ) 1 ⁄ 8" (3 ) 1 ⁄4" (6 ) Low-E Glass Insect Screen sill head meeting rail Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening 1 7⁄16" (37) • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass1 5 ⁄16 " (3 3 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass Insect Screenjambjamb 1 11 ⁄16" (43) Clear Opening (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) Low-E Glass Insect Screen jambjamb 1 11 ⁄16" (43) Clear Opening 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y 50 SINGLE-HUNG WINDOWS • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. Arch Single-Hung Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Arch Single-Hung, Existing Framed Opening Horizontal Section Arch Single-Hung, Existing Framed Opening N o F l a n g e 1 3 ⁄4" (4 4 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄16 " (5 6 ) Low-E Glass Insect Screen sill head meeting rail Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening 1 7⁄16" (37) (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass Insect Screenjambjamb 1 11 ⁄16" (43) Clear Opening Arch single-hung windows are not available with insert or flush fin frames. 51 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES Horizontal Section Twin or Triple Single-Hung Vertical Section Transom Over Single-Hung 6 3 ⁄4" (1 7 1 ) Horizontal Section Picture With Flanking Single-Hung In t e g r a l s 6 3 ⁄4" (171) 6 3 ⁄4" (171) Single-Hung Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 See pages 88-93 for joining details. Low-E Glass Insect Screen 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d Gl a s s 1 " (25) 3 1 ⁄4" (83) 3 1 ⁄ 8" (7 9 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄16 " (5 6 ) 1 ⁄4" (6 ) 1 ⁄8" (3 ) 1 ⁄ 8" (3 ) 1 ⁄4" (6 ) sill head meeting rail Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) Insect Screen Low-E Glass jambjamb 1 3 ⁄4" (44) Clear Opening Vertical Section Stucco Exterior Horizontal Section Stucco Exterior 1" F l a n g e S e t b a c k W i t h S t u c c o K e y (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass1 3 ⁄ 8" (3 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass Insect Screenjambjamb Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d Gl a s s 1 3 ⁄8" (35) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄ 16 " (5 6 ) sill head meeting rail Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening Vertical SectionHorizontal Section 1 3/8" F l a n g e S e t b a c k • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. 52 SINGLE-HUNG WINDOWS Single-Hung Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Existing Framed Opening Vertical Section Existing Window Opening Horizontal Section Existing Window Opening Horizontal Section Existing Framed Opening No F l a n g e In s e r t Low-E Glass Insect Screen 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u c t e d Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 1 ⁄4" (6 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄16 " (5 6 ) sill head meeting rail Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass Insect Screenjambjamb Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Ex i s t i n g O p e n i n g Un o b s t r u c t e d Gl a s s 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Un o b s t r u c t e d Gl a s s 2 3 ⁄16 " (5 6 ) 3 1 ⁄4" (83) sill head meeting rail Andersen® Exterior Sill Extender (optional) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen (79)(79) 3 1 ⁄8" Window Dimension Width Existing Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb 1 3 ⁄4" (44) Clear Opening Integral details shown on previous page. Installation accessories are available for windows with insert frame; see page 120. See pages 88-93 for joining details. • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. continued on next page 53 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 100 SERIES Single-Hung Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Existing Aluminum Frame Window Opening Horizontal Section Existing Aluminum Frame Window Opening Fl u s h F i n * 3 1 ⁄4" (83) 3 ⁄8" (10) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) 1 3 ⁄8" (35) 1 3 ⁄4" (4 4 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u s t e d Gl a s s 3 ⁄16 " (5 ) 1 3 ⁄4" (4 4 ) 3 ⁄16 " (5 ) 1 5 ⁄ 8" (4 1 ) 1 5 ⁄8" (4 1 ) Un o b s t r u s t e d Gl a s s 2 3 ⁄ 16 " (5 6 ) sill head Low-E Glass Andersen® Interior Flat Trim Insect Screen Integral details shown on page 52. Installation accessories are available for windows with flush fin frame; see page 120. See pages 88-93 for joining details. • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. (continued) Window Dimension Width Existing Opening 3 1 ⁄4" (8 3 ) 3 ⁄16" (5) 3 ⁄16" (5) 3 ⁄ 8" (1 0 ) 1 5 ⁄8" (41) 1 5 ⁄8" (41) jambjamb (79)(79) 3 1 ⁄8"3 1 ⁄8"Unobstr. Glass 1 3 ⁄4" (44) Clear Opening Insect Screen Low-E Glass Andersen® Interior Flat Trim 54 SINGLE-HUNG WINDOWS • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on pages 60-61. Custom-size windows are available in 1 ⁄8" (3) increments. See page 97 for custom sizes and specifications. 2020 2620 2026 2626 2030 2630 2036 2636 2040 2640 2046 2646 2050 2650 2056 2656 3020 3620 3026 3626 3030 3630 3036 3636 3040 3640 3046 3646 3050 3650 3056 3656 3060 366020602660 2010 2016 2616 3016 3616 2610 3010 3610 4020 4026 4030 4036 4040 4046 4050 4056 4060 4016 4010 4620 4626 4630 4636 4640 4646 4650 4656 4660 4616 4610 5020 5026 5030 5036 5040 5046 5050 5056 5060 5016 5010 5620 5626 5630 5636 5640 5646 5650 5656 5660 5616 5610 6020 6026 6030 6036 6040 6046 6050 6056 6060 6016 6010 Window Dimension Unobstructed Glass (width of single sash) Minimum Rough Opening Table of Gliding Active-Stationary or Stationary-Active Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 10 9/16" 13 9/16" 2'-11 1/2" 3'-0" 19 9/16" 3'-11 1/2" 4'-0" 16 9/16" 3'-5 1/2" 3'-6" 7 9/16" 1'-11 1/2" 2'-0" 4'-5 1/2" 4'-6" 22 9/16"25 9/16" 4'-11 1/2" 5'-0" 28 9/16" 5'-5 1/2" 5'-6"6'-0" 5'-11 1/2" 31 9/16" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" CUSTOM WIDTHS — 23 1 ⁄2" to 71 1 ⁄2" CU S T O M H E I G H T S — 11 1 ⁄ 2" t o 71 1 ⁄2" (749) (762) (268) (902) (914) (344) (1207) (1219) (496) (1054) (1067) (420) (597) (610) (192) (1359) (1372) (573) (1511) (1524) (649) (1664) (1676) (725) (1816) (1829) (801) (44 5 ) (45 7 ) (28 6 ) (29 2 ) (30 5 ) (13 3 ) (59 7 ) (61 0 ) (43 8 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (89 5 ) Choose active-stationary (XO) sash or stationary-active (OX) sash as viewed from the exterior. Two locks are standard on all heights greater than 4'-2" (1270). Grille patterns shown on page 65. Details shown on pages 66-67. Active-Stationary Stationary-Active 55 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on pages 62-63. 5016 6016 7016 7616 8016 8616 5020 6020 7020 7620 8020 8620 5026 6026 7026 7626 8026 8626 5030 6030 7030 7630 8030 8630 5036 6036 7036 7636 8036 8636 5040 6040 7040 7640 8040 8640 5046 6046 7046 7646 8046 8646 5050 6050 7050 7650 8050 8650 5056 6056 7056 7656 8056 8656 5060 6060 7060 7660 8060 8660 Window Dimension Unobstructed Glass (width of center sash) Unobstructed Glass (width of single venting sash) Minimum Rough Opening Table of Gliding Active-Stationary-Active 1:2:1 Sash Ratio Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 11 1/4" 1' - 5 1/2" 1' - 6 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 6'-0" 5'-11 1/2" 33 7/8"39 7/8" 6'-11 1/2" 7'-0" 45 7/8" 7'-11 1/2" 8'-0" 27 7/8" 4'-11 1/2" 5'-0" 42 7/8" 7'-5 1/2" 7'-6" 48 7/8" 8'-5 1/2" 8'-6" CUSTOM WIDTHS — 59 1 ⁄2" to 143 1 ⁄2" CU S T O M H E I G H T S — 17 1 ⁄ 2" t o 71 1 ⁄ 2" 13 17/32"16 17/32"19 17/32"10 17/32"18 1/32"21 1/32" (44 5 ) (45 7 ) (28 6 ) (59 7 ) (61 0 ) (43 8 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (89 5 ) (1816) (1829) (861) (2121) (2134) (1013) (2426) (2438) (1165) (1511) (1524) (708) (2273) (2286) (1089) (2578) (2591) (1242) (344)(420)(496)(267)(458)(534) Notes on next page also apply to this page. 56 GLIDING WINDOWS Custom-size windows are available in 1 ⁄8" (3) increments. See page 97 for custom sizes and specifications. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on pages 62-63. 10016 11016 12016 10020 11020 12020 10026 11026 12026 10030 11030 12030 10036 11036 12036 10040 11040 12040 10046 11046 12046 10050 11050 12050 10056 11056 12056 10060 11060 12060 9016 9020 9026 9030 9036 9040 9046 9050 9056 9060 69 7/8" 11'-11 1/2" 12'-0" 57 7/8" 9'-11 1/2" 10'-0" 63 7/8" 10'-11 1/2" 11'-0" 51 7/8" 8'-11 1/2" 9'-0" 31 17/32"25 17/32"28 17/32"22 17/32" (3645) (3658) (1775) (3035) (3048) (1470) (3340) (3353) (1623) (2731) (2743) (1318) (801)(648)(725)(572) Exterior view shown. Active-stationary-active (XOX) sash with a 1:2:1 sash ratio. Two locks for each sash are standard on all heights greater than 4'-2" (1270). Grille patterns shown on page 65. Details shown on pages 66-67. Active-Stationary-Active 57 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES 4016 5016 6016 7016 7616 8016 4020 5020 6020 7020 7620 8020 4026 5026 6026 7026 7626 8026 4030 5030 6030 7030 7630 8030 4036 5036 6036 7036 7636 8036 4040 5040 6040 7040 7640 8040 4046 5046 6046 7046 7646 8046 4050 5050 6050 7050 7650 8050 4056 5056 6056 7056 7656 8056 4060 5060 6060 7060 7660 8060 8616 8620 8626 8630 8636 8640 8646 8650 8656 8660 Window Dimension Minimum Rough Opening Table of Gliding Active-Stationary-Active 1:1:1 Sash Ratio Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 11 1/4" 1' - 5 1/2" 1' - 6 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 6'-0" 5'-11 1/2" 20 11/32"24 11/32" 6'-11 1/2" 7'-0" 28 11/32" 7'-11 1/2" 8'-0" 16 11/32" 4'-11 1/2" 5'-0" 26 11/32" 7'-5 1/2" 7'-6" 12 11/32" 3'-11 1/2" 4'-0" CUSTOM WIDTHS — 47 1 ⁄2" to 101 1 ⁄2" CU S T O M H E I G H T S — 17 1 ⁄ 2" t o 71 1 ⁄ 2" 30 11/32" 8'-5 1/2" 8'-6" 20 9/32"24 9/32"28 9/32"16 9/32"26 9/32"12 9/32"30 9/32" Unobstructed Glass (width of center sash) Unobstructed Glass (width of single venting sash) (44 5 ) (45 7 ) (28 6 ) (59 7 ) (61 0 ) (43 8 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (10 5 4 ) (10 6 7 ) (89 5 ) (1816) (1829) (517) (2121) (2134) (618) (2426) (2438) (720) (1511) (1524) (415) (2273) (2286) (669) (1207) (1219) (313) (2578) (2591) (771) (516)(617)(719)(414)(668)(312)(770) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). See table on pages 64-65. Custom-size windows are available in 1 ⁄8" (3) increments. See page 97 for custom sizes and specifications. Exterior view shown. Sash configuration is active-stationary-active (XOX) with a 1:1:1 equal sash ratio. Two locks are standard on all heights greater than 4'-2" (1270). Details shown on pages 66-67. Active-Stationary-Active 58 GLIDING WINDOWS 30363016 30403020 30503020 40364016 40404020 40504020 50365016 50405020 50505020 60366016 60406020 60506020 Window Dimension Unobstructed Glass (upper sash only) Minimum Rough Opening Table of Picture Over Gliding Window With Active-Stationary or Stationary-Active Sash Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 53 1/4" 4'-11 1/2" 5'-0"6'-0" 5'-11 1/2" 65 1/4" 4' - 1 1 1/2" 5' - 0 " 35 1/4" 5' - 1 1 1/2" 6' - 0 " 41 1/4" 7' - 0 " 6' - 1 1 1/2" 53 1/4" (902) (914) (743) (1207) (1219) (1048) (1511) (1524) (1353) (1816) (1829) (1657) (18 1 6 ) (18 2 9 ) (10 4 8 ) (15 1 1 ) (15 2 4 ) (89 5 ) (2 1 2 1 ) (21 3 4 ) (13 5 3 ) Choose picture over gliding active-stationary (XO) sash or picture over gliding stationary-active (OX) sash as viewed from the exterior. Windows have one continuous outer frame. For unobstructed glass dimensions of lower sash, see page 55. Grille patterns shown on page 65. Details shown on pages 66-67. Picture Over Gliding With Active-Stationary Sash Picture Over Gliding With Stationary-Active Sash • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Exterior view shown. Picture over active-stationary-active (XOX) sash with a 1:2:1 sash ratio. Windows have one continuous outer frame. For unobstructed glass dimensions of lower sash, see pages 56-57. Grille patterns shown on page 65. Details shown on pages 66-67. 60366016 60406020 60506020 70367016 70407020 70507020 80368016 80408020 80508020 90369016 90409020 90509020 Window Dimension Unobstructed Glass (upper sash only) Minimum Rough Opening Table of Picture Window Over Gliding With Active-Stationary-Active 1:2:1 Sash Ratio Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 6'-0" 5'-11 1/2" 65 1/4" 4' - 1 1 1/2" 5' - 0 " 35 1/4" 5' - 1 1 1/2" 6' - 0 " 41 1/4" 7' - 0 " 6' - 1 1 1/2" 53 1/4" 77 1/4" 6'-11 1/2" 7'-0" 89 1/4" 7'-11 1/2" 8'-0" 101 1/4" 8'-11 1/2" 9'-0" (1816) (1829) (1657) (18 1 6 ) (18 2 9 ) (10 4 8 ) (15 1 1 ) (15 2 4 ) (89 5 ) (2 1 2 1 ) (21 3 4 ) (13 5 3 ) (2121) (2134) (1962) (2426) (2438) (2267) (2731) (2743) (2572) Active-Stationary-Active 59 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES continued on next page Gliding Active-Stationary or Stationary-Active Sash Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Total Glass Area Sq. Ft./(m2) Fixed Sash Glass Area Sq. Ft./(m2) Active Sash Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 2010 0.45 (0.04) 8 1/16"(204) 8"(203) 0.55 (0.05) 0.28 (0.03) 0.27 (0.03) 0.45 (0.04) 72 1/2"(1842) 1.88 (0.17) 2016 0.78 (0.07) 8 1/16"(204) 14"(356) 1.18 (0.11) 0.59 (0.05) 0.59 (0.05) 0.78 (0.07) 66 1/2"(1689) 2.86 (0.27) 2020 1.12 (0.10) 8 1/16"(204) 20"(508) 1.81 (0.17) 0.91 (0.08) 0.90 (0.08) 1.12 (0.10) 60 1/2"(1537) 3.84 (0.36) 2026 1.45 (0.13) 8 1/16"(204) 26"(660) 2.44 (0.23) 1.22 (0.11) 1.21 (0.11) 1.45 (0.13) 54 1/2"(1384) 4.81 (0.45) 2030 1.79 (0.17) 8 1/16"(204) 32"(813) 3.07 (0.28) 1.54 (0.14) 1.53 (0.14) 1.79 (0.17) 48 1/2"(1232) 5.79 (0.54) 2036 2.12 (0.20) 8 1/16"(204) 38"(965) 3.69 (0.34) 1.85 (0.17) 1.84 (0.17) 2.12 (0.20) 42 1/2"(1080) 6.77 (0.63) 2040 2.46 (0.23) 8 1/16"(204) 44"(1118) 4.32 (0.40) 2.17 (0.20) 2.16 (0.20) 2.46 (0.23) 36 1/2"(927) 7.75 (0.72) 2046 2.79 (0.26) 8 1/16"(204) 50"(1270) 4.95 (0.46) 2.48 (0.23) 2.47 (0.23) 2.79 (0.26) 30 1/2"(775) 8.73 (0.81) 2050 3.13 (0.29) 8 1/16"(204) 56"(1422) 5.58 (0.52) 2.80 (0.26) 2.78 (0.26) 3.13 (0.29) 24 1/2"(622) 9.71 (0.90) 2056 3.46 (0.32) 8 1/16"(204) 62"(1575) 6.21 (0.58) 3.11 (0.29) 3.10 (0.29) 3.46 (0.32) 18 1/2"(470) 10.69 (0.99) 2060 3.80 (0.35) 8 1/16"(204) 68"(1727) 6.84 (0.64) 3.43 (0.32) 3.41 (0.32) 3.80 (0.35) 12 1/2"(318) 11.67 (1.08) 2610 0.61 (0.06) 11 1/16"(280) 8"(203) 0.77 (0.07) 0.39 (0.04) 0.38 (0.04) 0.61 (0.06) 72 1/2"(1842) 2.36 (0.22) 2616 1.07 (0.10) 11 1/16"(280) 14"(356) 1.65 (0.15) 0.83 (0.08) 0.82 (0.08) 1.07 (0.10) 66 1/2"(1689) 3.59 (0.33) 2620 1.53 (0.14) 11 1/16"(280) 20"(508) 2.53 (0.23) 1.27 (0.12) 1.26 (0.12) 1.53 (0.14) 60 1/2"(1537) 4.81 (0.45) 2626 1.99 (0.19) 11 1/16"(280) 26"(660) 3.41 (0.32) 1.71 (0.16) 1.70 (0.16) 1.99 (0.19) 54 1/2"(1384) 6.04 (0.56) 2630 2.45 (0.23) 11 1/16"(280) 32"(813) 4.28 (0.40) 2.15 (0.20) 2.14 (0.20) 2.45 (0.23) 48 1/2"(1232) 7.27 (0.68) 2636 2.91 (0.27) 11 1/16"(280) 38"(965) 5.16 (0.48) 2.59 (0.24) 2.58 (0.24) 2.91 (0.27) 42 1/2"(1080) 8.50 (0.79) 2640 3.37 (0.31) 11 1/16"(280) 44"(1118) 6.04 (0.56) 3.03 (0.28) 3.01 (0.28) 3.37 (0.31) 36 1/2"(927) 9.73 (0.90) 2646 3.83 (0.36) 11 1/16"(280) 50"(1270) 6.92 (0.64) 3.47 (0.32) 3.45 (0.32) 3.83 (0.36) 30 1/2"(775) 10.96 (1.02) 2650 4.29 (0.40) 11 1/16"(280) 56"(1422) 7.80 (0.72) 3.91 (0.36) 3.89 (0.36) 4.29 (0.40) 24 1/2"(622) 12.19 (1.13) 2656 4.75 (0.44) 11 1/16"(280) 62"(1575) 8.68 (0.81) 4.35 (0.40) 4.33 (0.40) 4.75 (0.44) 18 1/2"(470) 13.42 (1.25) 2660 5.21 (0.48) 11 1/16"(280) 68"(1727) 9.56 (0.89) 4.79 (0.44) 4.77 (0.44) 5.21 (0.48) 12 1/2"(318) 14.65 (1.36) 3010 0.78 (0.07) 14 1/16"(357) 8"(203) 0.99 (0.09) 0.49 (0.05) 0.49 (0.05) 0.78 (0.07) 72 1/2"(1842) 2.84 (0.26) 3016 1.36 (0.13) 14 1/16"(357) 14"(356) 2.12 (0.20) 1.06 (0.10) 1.06 (0.10) 1.36 (0.13) 66 1/2"(1689) 4.31 (0.40) 3020 1.95 (0.18) 14 1/16"(357) 20"(508) 3.25 (0.30) 1.63 (0.15) 1.62 (0.15) 1.95 (0.18) 60 1/2"(1537) 5.79 (0.54) 3026 2.53 (0.24) 14 1/16"(357) 26"(660) 4.37 (0.41) 2.19 (0.20) 2.18 (0.20) 2.53 (0.24) 54 1/2"(1384) 7.27 (0.68) 3030 3.12 (0.29) 14 1/16"(357) 32"(813) 5.50 (0.51) 2.76 (0.26) 2.75 (0.26) 3.12 (0.29) 48 1/2"(1232) 8.75 (0.81) 3036 3.70 (0.34) 14 1/16"(357) 38"(965) 6.63 (0.62) 3.32 (0.31) 3.31 (0.31) 3.70 (0.34) 42 1/2"(1080) 10.23 (0.95) 3040 4.29 (0.40) 14 1/16"(357) 44"(1118) 7.76 (0.72) 3.89 (0.36) 3.87 (0.36) 4.29 (0.40) 36 1/2"(927) 11.71 (1.09) 3046 4.87 (0.45) 14 1/16"(357) 50"(1270) 8.89 (0.83) 4.45 (0.41) 4.44 (0.41) 4.87 (0.45) 30 1/2"(775) 13.19 (1.23) 3050 5.46 (0.51) 14 1/16"(357) 56"(1422) 10.02 (0.93) 5.02 (0.47) 5.00 (0.46) 5.46 (0.51) 24 1/2"(622) 14.67 (1.36) 3056 6.04 (0.56) 14 1/16"(357) 62"(1575) 11.15 (1.04) 5.58 (0.52) 5.56 (0.52) 6.04 (0.56) 18 1/2"(470) 16.15 (1.50) 3060 6.63 (0.62) 14 1/16"(357) 68"(1727) 12.28 (1.14) 6.15 (0.57) 6.13 (0.57) 6.63 (0.62) 12 1/2"(318) 17.63 (1.64) 3610 0.95 (0.09) 17 1/16"(433) 8"(203) 1.21 (0.11) 0.60 (0.06) 0.60 (0.06) 0.95 (0.09) 72 1/2"(1842) 3.31 (0.31) 3616 1.66 (0.15) 17 1/16"(433) 14"(356) 2.59 (0.24) 1.29 (0.12) 1.29 (0.12) 1.66 (0.15) 66 1/2"(1689) 5.04 (0.47) 3620 2.37 (0.22) 17 1/16"(433) 20"(508) 3.96 (0.37) 1.98 (0.18) 1.98 (0.18) 2.37 (0.22) 60 1/2"(1537) 6.77 (0.63) 3626 3.08 (0.29) 17 1/16"(433) 26"(660) 5.34 (0.50) 2.67 (0.25) 2.67 (0.25) 3.08 (0.29) 54 1/2"(1384) 8.50 (0.79) 3630 3.79 (0.35) 17 1/16"(433) 32"(813) 6.72 (0.62) 3.36 (0.31) 3.36 (0.31) 3.79 (0.35) 48 1/2"(1232) 10.23 (0.95) 3636 4.50 (0.42) 17 1/16"(433) 38"(965) 8.10 (0.75) 4.06 (0.38) 4.04 (0.38) 4.50 (0.42) 42 1/2"(1080) 11.96 (1.11) 3640 5.21 (0.48) 17 1/16"(433) 44"(1118) 9.48 (0.88) 4.75 (0.44) 4.73 (0.44) 5.21 (0.48) 36 1/2"(927) 13.69 (1.27) 3646 5.92 (0.55) 17 1/16"(433) 50"(1270) 10.86 (1.01) 5.44 (0.50) 5.42 (0.50) 5.92 (0.55) 30 1/2"(775) 15.42 (1.43) 3650 6.63 (0.62) 17 1/16"(433) 56"(1422) 12.24 (1.14) 6.13 (0.57) 6.11 (0.57) 6.63 (0.62) 24 1/2"(622) 17.15 (1.59) 3656 7.34 (0.68) 17 1/16"(433) 62"(1575) 13.62 (1.26) 6.82 (0.63) 6.80 (0.63) 7.34 (0.68) 18 1/2"(470) 18.88 (1.75) 3660 8.05 (0.75) 17 1/16"(433) 68"(1727) 14.99 (1.39) 7.51 (0.70) 7.49 (0.70) 8.05 (0.75) 12 1/2"(318) 20.61 (1.91) 4010 1.11 (0.10) 20 1/16"(509) 8"(203) 1.43 (0.13) 0.71 (0.07) 0.71 (0.07) 1.11 (0.10) 72 1/2"(1842) 3.79 (0.35) 4016 1.95 (0.18) 20 1/16"(509) 14"(356) 3.05 (0.28) 1.53 (0.14) 1.53 (0.14) 1.95 (0.18) 66 1/2"(1689) 5.77 (0.54) 4020 2.78 (0.26) 20 1/16"(509) 20"(508) 4.68 (0.44) 2.34 (0.22) 2.34 (0.22) 2.78 (0.26) 60 1/2"(1537) 7.75 (0.72) 4026 3.62 (0.34) 20 1/16"(509) 26"(660) 6.31 (0.59) 3.16 (0.29) 3.15 (0.29) 3.62 (0.34) 54 1/2"(1384) 9.73 (0.90) 4030 4.45 (0.41) 20 1/16"(509) 32"(813) 7.94 (0.74) 3.97 (0.37) 3.97 (0.37) 4.45 (0.41) 48 1/2"(1232) 11.71 (1.09) 4036 5.29 (0.49) 20 1/16"(509) 38"(965) 9.57 (0.89) 4.79 (0.44) 4.78 (0.44) 5.29 (0.49) 42 1/2"(1080) 13.69 (1.27) 4040 ◊6.12 (0.57) 20 1/16"(509) 44"(1118) 11.20 (1.04) 5.60 (0.52) 5.59 (0.52) 6.12 (0.57) 36 1/2"(927) 15.67 (1.46) 4046 ◊6.96 (0.65) 20 1/16"(509) 50"(1270) 12.83 (1.19) 6.42 (0.60) 6.41 (0.60) 6.96 (0.65) 30 1/2"(775) 17.65 (1.64) 4050 ◊7.79 (0.72) 20 1/16"(509) 56"(1422) 14.46 (1.34) 7.24 (0.67) 7.22 (0.67) 7.79 (0.72) 24 1/2"(622) 19.63 (1.82) 4056 ◊8.63 (0.80) 20 1/16"(509) 62"(1575) 16.08 (1.49) 8.05 (0.75) 8.03 (0.75) 8.63 (0.80) 18 1/2"(470) 21.61 (2.01) 4060 ◊9.46 (0.88) 20 1/16"(509) 68"(1727) 17.71 (1.65) 8.87 (0.82) 8.85 (0.82) 9.46 (0.88) 12 1/2"(318) 23.59 (2.19) 4610 1.28 (0.12) 23 1/16"(585) 8"(203) 1.64 (0.15) 0.82 (0.08) 0.82 (0.08) 1.28 (0.12) 72 1/2"(1842) 4.27 (0.40) 4616 2.24 (0.21) 23 1/16"(585) 14"(356) 3.52 (0.33) 1.76 (0.16) 1.76 (0.16) 2.24 (0.21) 66 1/2"(1689) 6.50 (0.60) 4620 3.20 (0.30) 23 1/16"(585) 20"(508) 5.40 (0.50) 2.70 (0.25) 2.70 (0.25) 3.20 (0.30) 60 1/2"(1537) 8.73 (0.81) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 60 GLIDING WINDOWS Gliding Active-Stationary or Stationary-Active Sash Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Total Glass Area Sq. Ft./(m2) Fixed Sash Glass Area Sq. Ft./(m2) Active Sash Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 4626 4.16 (0.39) 23 1/16"(585) 26"(660) 7.28 (0.68) 3.64 (0.34) 3.64 (0.34) 4.16 (0.39) 54 1/2"(1384) 10.96 (1.02) 4630 5.12 (0.48) 23 1/16"(585) 32"(813) 9.16 (0.85) 4.58 (0.43) 4.58 (0.43) 5.12 (0.48) 48 1/2"(1232) 13.19 (1.23) 4636 ◊6.08 (0.56) 23 1/16"(585) 38"(965) 11.04 (1.03) 5.52 (0.51) 5.51 (0.51) 6.08 (0.56) 42 1/2"(1080) 15.42 (1.43) 4640 ◊7.04 (0.65) 23 1/16"(585) 44"(1118) 12.92 (1.20) 6.46 (0.60) 6.45 (0.60) 7.04 (0.65) 36 1/2"(927) 17.65 (1.64) 4646 ◊8.00 (0.74) 23 1/16"(585) 50"(1270) 14.80 (1.37) 7.40 (0.69) 7.39 (0.69) 8.00 (0.74) 30 1/2"(775) 19.88 (1.85) 4650 ◊8.96 (0.83) 23 1/16"(585) 56"(1422) 16.67 (1.55) 8.34 (0.78) 8.33 (0.77) 8.96 (0.83) 24 1/2"(622) 22.11 (2.05) 4656 ◊9.92 (0.92) 23 1/16"(585) 62"(1575) 18.55 (1.72) 9.28 (0.86) 9.27 (0.86) 9.92 (0.92) 18 1/2"(470) 24.34 (2.26) 4660 ◊10.88 (1.01) 23 1/16"(585) 68"(1727) 20.43 (1.90) 10.23 (0.95) 10.21 (0.95) 10.88 (1.01) 12 1/2"(318) 26.56 (2.47) 5010 1.45 (0.13) 26 1/16"(661) 8"(203) 1.86 (0.17) 0.93 (0.09) 0.93 (0.09) 1.45 (0.13) 72 1/2"(1842) 4.75 (0.44) 5016 2.53 (0.24) 26 1/16"(661) 14"(356) 3.99 (0.37) 2.00 (0.19) 1.99 (0.19) 2.53 (0.24) 66 1/2"(1689) 7.23 (0.67) 5020 3.62 (0.34) 26 1/16"(661) 20"(508) 6.12 (0.57) 3.06 (0.28) 3.06 (0.28) 3.62 (0.34) 60 1/2"(1537) 9.71 (0.90) 5026 4.70 (0.44) 26 1/16"(661) 26"(660) 8.25 (0.77) 4.13 (0.38) 4.12 (0.38) 4.70 (0.44) 54 1/2"(1384) 12.19 (1.13) 5030 ◊5.79 (0.54) 26 1/16"(661) 32"(813) 10.38 (0.96) 5.19 (0.48) 5.18 (0.48) 5.79 (0.54) 48 1/2"(1232) 14.67 (1.36) 5036 ◊6.87 (0.64) 26 1/16"(661) 38"(965) 12.51 (1.16) 6.26 (0.58) 6.25 (0.58) 6.87 (0.64) 42 1/2"(1080) 17.15 (1.59) 5040 ◊7.96 (0.74) 26 1/16"(661) 44"(1118) 14.64 (1.36) 7.32 (0.68) 7.31 (0.68) 7.96 (0.74) 36 1/2"(927) 19.63 (1.82) 5046 ◊9.04 (0.84) 26 1/16"(661) 50"(1270) 16.76 (1.56) 8.39 (0.78) 8.38 (0.78) 9.04 (0.84) 30 1/2"(775) 22.11 (2.05) 5050 ◊10.13 (0.94) 26 1/16"(661) 56"(1422) 18.89 (1.76) 9.45 (0.88) 9.44 (0.88) 10.13 (0.94) 24 1/2"(622) 24.59 (2.28) 5056 ◊11.21 (1.04) 26 1/16"(661) 62"(1575) 21.02 (1.95) 10.52 (0.98) 10.50 (0.98) 11.21 (1.04) 18 1/2"(470) 27.06 (2.51) 5060 ◊12.30 (1.14) 26 1/16"(661) 68"(1727) 23.15 (2.15) 11.58 (1.08) 11.57 (1.07) 12.30 (1.14) 12 1/2"(318) 29.54 (2.74) 5610 1.61 (0.15) 29 1/16"(738) 8"(203) 2.08 (0.19) 1.04 (0.10) 1.04 (0.10) 1.61 (0.15) 72 1/2"(1842) 5.23 (0.49) 5616 2.82 (0.26) 29 1/16"(738) 14"(356) 4.46 (0.41) 2.23 (0.21) 2.23 (0.21) 2.82 (0.26) 66 1/2"(1689) 7.96 (0.74) 5620 4.03 (0.37) 29 1/16"(738) 20"(508) 6.84 (0.64) 3.42 (0.32) 3.42 (0.32) 4.03 (0.37) 60 1/2"(1537) 10.69 (0.99) 5626 5.24 (0.49) 29 1/16"(738) 26"(660) 9.22 (0.86) 4.61 (0.43) 4.61 (0.43) 5.24 (0.49) 54 1/2"(1384) 13.42 (1.25) 5630 ◊6.45 (0.60) 29 1/16"(738) 32"(813) 11.60 (1.08) 5.80 (0.54) 5.79 (0.54) 6.45 (0.60) 48 1/2"(1232) 16.15 (1.50) 5636 ◊7.66 (0.71) 29 1/16"(738) 38"(965) 13.98 (1.30) 6.99 (0.65) 6.98 (0.65) 7.66 (0.71) 42 1/2"(1080) 18.88 (1.75) 5640 ◊8.87 (0.82) 29 1/16"(738) 44"(1118) 16.35 (1.52) 8.18 (0.76) 8.17 (0.76) 8.87 (0.82) 36 1/2"(927) 21.61 (2.01) 5646 ◊10.08 (0.94) 29 1/16"(738) 50"(1270) 18.73 (1.74) 9.37 (0.87) 9.36 (0.87) 10.08 (0.94) 30 1/2"(775) 24.34 (2.26) 5650 ◊11.29 (1.05) 29 1/16"(738) 56"(1422) 21.11 (1.96) 10.56 (0.98) 10.55 (0.98) 11.29 (1.05) 24 1/2"(622) 27.06 (2.51) 5656 ◊12.50 (1.16) 29 1/16"(738) 62"(1575) 23.49 (2.18) 11.75 (1.09) 11.74 (1.09) 12.50 (1.16) 18 1/2"(470) 29.79 (2.77) 5660 ◊13.71 (1.27) 29 1/16"(738) 68"(1727) 25.87 (2.40) 12.94 (1.20) 12.92 (1.20) 13.71 (1.27) 12 1/2"(318) 32.52 (3.02) 6010 1.78 (0.17) 32 1/16"(814) 8"(203) 2.30 (0.21) 1.15 (0.11) 1.15 (0.11) 1.78 (0.17) 72 1/2"(1842) 5.71 (0.53) 6016 3.11 (0.29) 32 1/16"(814) 14"(356) 4.93 (0.46) 2.47 (0.23) 2.46 (0.23) 3.11 (0.29) 66 1/2"(1689) 8.69 (0.81) 6020 4.45 (0.41) 32 1/16"(814) 20"(508) 7.56 (0.70) 3.78 (0.35) 3.78 (0.35) 4.45 (0.41) 60 1/2"(1537) 11.67 (1.08) 6026 ◊5.78 (0.54) 32 1/16"(814) 26"(660) 10.19 (0.95) 5.10 (0.47) 5.09 (0.47) 5.78 (0.54) 54 1/2"(1384) 14.65 (1.36) 6030 ◊7.12 (0.66) 32 1/16"(814) 32"(813) 12.82 (1.19) 6.41 (0.60) 6.40 (0.59) 7.12 (0.66) 48 1/2"(1232) 17.63 (1.64) 6036 ◊8.45 (0.79) 32 1/16"(814) 38"(965) 15.44 (1.43) 7.73 (0.72) 7.72 (0.72) 8.45 (0.79) 42 1/2"(1080) 20.61 (1.91) 6040 ◊9.79 (0.91) 32 1/16"(814) 44"(1118) 18.07 (1.68) 9.04 (0.84) 9.03 (0.84) 9.79 (0.91) 36 1/2"(927) 23.59 (2.19) 6046 ◊11.12 (1.03) 32 1/16"(814) 50"(1270) 20.70 (1.92) 10.36 (0.96) 10.34 (0.96) 11.12 (1.03) 30 1/2"(775) 26.56 (2.47) 6050 ◊12.46 (1.16) 32 1/16"(814) 56"(1422) 23.33 (2.17) 11.67 (1.08) 11.66 (1.08) 12.46 (1.16) 24 1/2"(622) 29.54 (2.74) 6056 ◊13.79 (1.28) 32 1/16"(814) 62"(1575) 25.96 (2.41) 12.99 (1.21) 12.97 (1.21) 13.79 (1.28) 18 1/2"(470) 32.52 (3.02) 6060 ◊15.13 (1.41) 32 1/16"(814) 68"(1727) 28.59 (2.66) 14.30 (1.33) 14.28 (1.33) 15.13 (1.41) 12 1/2"(318) 35.50 (3.30) (continued) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 61 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES Gliding Active-Stationary-Active 1:2:1 Sash Ratio Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Total Glass Area Sq. Ft./(m2) Fixed Sash Glass Area Sq. Ft./(m2) Single Active Sash Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Height Inches/(mm) 5016 1.16 (0.11)11 7/8"(302) 14"(356) 3.82 (0.36) 2.18 (0.20) 0.82 (0.08) 2.31 (0.21)66 1/2"(1689) 7.23 (0.67) 5020 1.65 (0.15)11 7/8"(302) 20"(508) 5.86 (0.54) 3.34 (0.31) 1.26 (0.12) 3.31 (0.31)60 1/2"(1537) 9.71 (0.90) 5026 2.15 (0.20)11 7/8"(302) 26"(660) 7.90 (0.73) 4.50 (0.42) 1.70 (0.16) 4.30 (0.40)54 1/2"(1384) 12.19 (1.13) 5030 2.64 (0.25)11 7/8"(302) 32"(813) 9.94 (0.92) 5.66 (0.53) 2.14 (0.20) 5.29 (0.49)48 1/2"(1232) 14.67 (1.36) 5036 3.14 (0.29)11 7/8"(302) 38"(965) 11.98 (1.11) 6.83 (0.63) 2.58 (0.24) 6.28 (0.58)42 1/2"(1080) 17.15 (1.59) 5040 3.64 (0.34)11 7/8"(302) 44"(1118) 14.02 (1.30) 7.99 (0.74) 3.01 (0.28) 7.27 (0.68)36 1/2"(927) 19.63 (1.82) 5046 4.13 (0.38)11 7/8"(302) 50"(1270) 16.06 (1.49) 9.15 (0.85) 3.45 (0.32) 8.26 (0.77)30 1/2"(775) 22.11 (2.05) 5050 4.63 (0.43)11 7/8"(302) 56"(1422) 18.09 (1.68) 10.31 (0.96) 3.89 (0.36) 9.25 (0.86)24 1/2"(622) 24.59 (2.28) 5056 5.12 (0.48)11 7/8"(302) 62"(1575) 20.13 (1.87) 11.47 (1.07) 4.33 (0.40) 10.25 (0.95)18 1/2"(470) 27.06 (2.51) 5060 5.62 (0.52)11 7/8"(302) 68"(1727) 22.17 (2.06) 12.63 (1.17) 4.77 (0.44) 11.24 (1.04)12 1/2"(318) 29.54 (2.74) 6016 1.45 (0.13)14 7/8"(378) 14"(356) 4.76 (0.44) 2.65 (0.25) 1.06 (0.10) 2.90 (0.27)66 1/2"(1689) 8.69 (0.81) 6020 2.07 (0.19)14 7/8"(378) 20"(508) 7.30 (0.68) 4.06 (0.38) 1.62 (0.15) 4.14 (0.38)60 1/2"(1537) 11.67 (1.08) 6026 2.69 (0.25)14 7/8"(378) 26"(660) 9.84 (0.91) 5.47 (0.51) 2.18 (0.20) 5.38 (0.50)54 1/2"(1384) 14.65 (1.36) 6030 3.31 (0.31)14 7/8"(378) 32"(813) 12.38 (1.15) 6.88 (0.64) 2.75 (0.26) 6.62 (0.62)48 1/2"(1232) 17.63 (1.64) 6036 3.93 (0.37)14 7/8"(378) 38"(965) 14.92 (1.39) 8.29 (0.77) 3.31 (0.31) 7.86 (0.73)42 1/2"(1080) 20.61 (1.91) 6040 4.55 (0.42)14 7/8"(378) 44"(1118) 17.45 (1.62) 9.71 (0.90) 3.87 (0.36) 9.10 (0.85)36 1/2"(927) 23.59 (2.19) 6046 5.17 (0.48)14 7/8"(378) 50"(1270) 19.99 (1.86) 11.12 (1.03) 4.44 (0.41) 10.35 (0.96)30 1/2"(775) 26.56 (2.47) 6050 5.79 (0.54)14 7/8"(378) 56"(1422) 22.53 (2.09) 12.53 (1.16) 5.00 (0.46) 11.59 (1.08)24 1/2"(622) 29.54 (2.74) 6056 6.41 (0.60)14 7/8"(378) 62"(1575) 25.07 (2.33) 13.94 (1.30) 5.56 (0.52) 12.83 (1.19)18 1/2"(470) 32.52 (3.02) 6060 7.04 (0.65)14 7/8"(378) 68"(1727) 27.61 (2.56) 15.35 (1.43) 6.13 (0.57) 14.07 (1.31)12 1/2"(318) 35.50 (3.30) 7016 1.74 (0.16)17 7/8"(455) 14"(356) 5.70 (0.53) 3.12 (0.29) 1.29 (0.12) 3.48 (0.32) 66 1/2"(1689) 10.15 (0.94) 7020 2.49 (0.23)17 7/8"(455) 20"(508) 8.74 (0.81) 4.78 (0.44) 1.98 (0.18) 4.97 (0.46) 60 1/2"(1537) 13.63 (1.27) 7026 3.23 (0.30)17 7/8"(455) 26"(660) 11.78 (1.09) 6.44 (0.60) 2.67 (0.25) 6.46 (0.60) 54 1/2"(1384) 17.11 (1.59) 7030 3.98 (0.37)17 7/8"(455) 32"(813) 14.81 (1.38) 8.10 (0.75) 3.36 (0.31) 7.96 (0.74) 48 1/2"(1232) 20.59 (1.91) 7036 4.72 (0.44)17 7/8"(455) 38"(965) 17.85 (1.66) 9.76 (0.91) 4.04 (0.38) 9.45 (0.88) 42 1/2"(1080) 24.06 (2.24) 7040 5.47 (0.51)17 7/8"(455) 44"(1118) 20.89 (1.94) 11.42 (1.06) 4.73 (0.44) 10.94 (1.02) 36 1/2"(927) 27.54 (2.56) 7046 6.21 (0.58)17 7/8"(455) 50"(1270) 23.93 (2.22) 13.09 (1.22) 5.42 (0.50) 12.43 (1.15) 30 1/2"(775) 31.02 (2.88) 7050 6.96 (0.65)17 7/8"(455) 56"(1422) 26.97 (2.51) 14.75 (1.37) 6.11 (0.57) 13.92 (1.29) 24 1/2"(622) 34.50 (3.21) 7056 7.71 (0.72)17 7/8"(455) 62"(1575) 30.01 (2.79) 16.41 (1.52) 6.80 (0.63) 15.41 (1.43) 18 1/2"(470) 37.98 (3.53) 7060 8.45 (0.79)17 7/8"(455) 68"(1727) 33.05 (3.07) 18.07 (1.68) 7.49 (0.70) 16.90 (1.57) 12 1/2"(318) 41.46 (3.85) 7616 1.89 (0.18)19 3/8"(493) 14"(356) 6.17 (0.57) 3.35 (0.31) 1.41 (0.13) 3.77 (0.35) 66 1/2"(1689) 10.88 (1.01) 7620 2.69 (0.25)19 3/8"(493) 20"(508) 9.46 (0.88) 5.14 (0.48) 2.16 (0.20) 5.39 (0.50) 60 1/2"(1537) 14.61 (1.36) 7626 3.50 (0.33)19 3/8"(493) 26"(660) 12.74 (1.18) 6.92 (0.64) 2.91 (0.27) 7.01 (0.65) 54 1/2"(1384) 18.34 (1.70) 7630 4.31 (0.40)19 3/8"(493) 32"(813) 16.03 (1.49) 8.71 (0.81) 3.66 (0.34) 8.62 (0.80) 48 1/2"(1232) 22.06 (2.05) 7636 5.12 (0.48)19 3/8"(493) 38"(965) 19.32 (1.80) 10.50 (0.98) 4.41 (0.41) 10.24 (0.95) 42 1/2"(1080) 25.79 (2.40) 7640 5.93 (0.55)19 3/8"(493) 44"(1118) 22.61 (2.10) 12.28 (1.14) 5.16 (0.48) 11.85 (1.10) 36 1/2"(927) 29.52 (2.74) 7646 6.74 (0.63)19 3/8"(493) 50"(1270) 25.90 (2.41) 14.07 (1.31) 5.91 (0.55) 13.47 (1.25) 30 1/2"(775) 33.25 (3.09) 7650 7.54 (0.70)19 3/8"(493) 56"(1422) 29.19 (2.71) 15.86 (1.47) 6.67 (0.62) 15.09 (1.40) 24 1/2"(622) 36.98 (3.44) 7656 8.35 (0.78)19 3/8"(493) 62"(1575) 32.48 (3.02) 17.64 (1.64) 7.42 (0.69) 16.70 (1.55) 18 1/2"(470) 40.71 (3.78) 7660 9.16 (0.85)19 3/8"(493) 68"(1727) 35.77 (3.32) 19.43 (1.81) 8.17 (0.76) 18.32 (1.70) 12 1/2"(318) 44.44 (4.13) 8016 2.03 (0.19)20 7/8"(531) 14"(356) 6.64 (0.62) 3.58 (0.33) 1.53 (0.14) 4.06 (0.38) 66 1/2"(1689) 11.61 (1.08) 8020 2.90 (0.27)20 7/8"(531) 20"(508) 10.17 (0.95) 5.50 (0.51) 2.34 (0.22) 5.81 (0.54) 60 1/2"(1537) 15.59 (1.45) 8026 3.77 (0.35)20 7/8"(531) 26"(660) 13.71 (1.27) 7.41 (0.69) 3.15 (0.29) 7.55 (0.70) 54 1/2"(1384) 19.56 (1.82) 8030 4.64 (0.43)20 7/8"(531) 32"(813) 17.25 (1.60) 9.32 (0.87) 3.97 (0.37) 9.29 (0.86) 48 1/2"(1232) 23.54 (2.19) 8036 5.52 (0.51)20 7/8"(531) 38"(965) 20.79 (1.93) 11.23 (1.04) 4.78 (0.44) 11.03 (1.02) 42 1/2"(1080) 27.52 (2.56) 8040 ◊6.39 (0.59)20 7/8"(531) 44"(1118) 24.33 (2.26) 13.14 (1.22) 5.59 (0.52) 12.77 (1.19) 36 1/2"(927) 31.50 (2.93) 8046 ◊7.26 (0.67)20 7/8"(531) 50"(1270) 27.87 (2.59) 15.06 (1.40) 6.41 (0.60) 14.51 (1.35) 30 1/2"(775) 35.48 (3.30) 8050 ◊8.13 (0.76)20 7/8"(531) 56"(1422) 31.41 (2.92) 16.97 (1.58) 7.22 (0.67) 16.25 (1.51) 24 1/2"(622) 39.46 (3.67) 8056 ◊9.00 (0.84)20 7/8"(531) 62"(1575) 34.95 (3.25) 18.88 (1.75) 8.03 (0.75) 18.00 (1.67) 18 1/2"(470) 43.44 (4.04) 8060 ◊9.87 (0.92)20 7/8"(531) 68"(1727) 38.48 (3.58) 20.79 (1.93) 8.85 (0.82) 19.74 (1.83) 12 1/2"(318) 47.42 (4.41) 8616 2.18 (0.20)22 3/8"(569) 14"(356) 7.10 (0.66) 3.82 (0.35) 1.64 (0.15) 4.36 (0.40) 66 1/2"(1689) 12.34 (1.15) 8620 3.11 (0.29)22 3/8"(569) 20"(508) 10.89 (1.01) 5.86 (0.54) 2.52 (0.23) 6.22 (0.58) 60 1/2"(1537) 16.56 (1.54) 8626 4.04 (0.38)22 3/8"(569) 26"(660) 14.68 (1.36) 7.89 (0.73) 3.39 (0.32) 8.09 (0.75) 54 1/2"(1384) 20.79 (1.93) 8630 4.98 (0.46)22 3/8"(569) 32"(813) 18.47 (1.72) 9.93 (0.92) 4.27 (0.40) 9.96 (0.92) 48 1/2"(1232) 25.02 (2.32) 8636 ◊5.91 (0.55)22 3/8"(569) 38"(965) 22.26 (2.07) 11.97 (1.11) 5.15 (0.48) 11.82 (1.10) 42 1/2"(1080) 29.25 (2.72) 8640 ◊6.84 (0.64)22 3/8"(569) 44"(1118) 26.05 (2.42) 14.00 (1.30) 6.02 (0.56) 13.69 (1.27) 36 1/2"(927) 33.48 (3.11) 8646 ◊7.78 (0.72)22 3/8"(569) 50"(1270) 29.84 (2.77) 16.04 (1.49) 6.90 (0.64) 15.55 (1.45) 30 1/2"(775) 37.71 (3.50) 8650 ◊8.71 (0.81)22 3/8"(569) 56"(1422) 33.63 (3.12) 18.08 (1.68) 7.77 (0.72) 17.42 (1.62) 24 1/2"(622) 41.94 (3.90) continued on next page• Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 62 GLIDING WINDOWS Gliding Active-Stationary-Active 1:2:1 Sash Ratio Window Opening and Area Specifications Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Total Glass Area Sq. Ft./(m2) Fixed Sash Glass Area Sq. Ft./(m2) Single Active Sash Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 8656 ◊9.64 (0.90)22 3/8"(569) 62"(1575) 37.41 (3.48) 20.11 (1.87) 8.65 (0.80) 19.29 (1.79) 18 1/2"(470) 46.17 (4.29) 8660 ◊10.58 (0.98)22 3/8"(569) 68"(1727) 41.20 (3.83) 22.15 (2.06) 9.53 (0.89) 21.15 (1.97) 12 1/2"(318) 50.40 (4.68) 9016 2.32 (0.22) 23 7/8"(607) 14"(356) 7.57 (0.70) 4.05 (0.38) 1.76 (0.16) 4.65 (0.43) 66 1/2"(1689) 13.06 (1.21) 9020 3.32 (0.31) 23 7/8"(607) 20"(508) 11.61 (1.08) 6.22 (0.58) 2.70 (0.25) 6.64 (0.62) 60 1/2"(1537) 17.54 (1.63) 9026 4.32 (0.40) 23 7/8"(607) 26"(660) 15.65 (1.45) 8.38 (0.78) 3.64 (0.34) 8.63 (0.80) 54 1/2"(1384) 22.02 (2.05) 9030 5.31 (0.49) 23 7/8"(607) 32"(813) 19.69 (1.83) 10.54 (0.98) 4.58 (0.43) 10.62 (0.99) 48 1/2"(1232) 26.50 (2.46) 9036 ◊6.31 (0.59) 23 7/8"(607) 38"(965) 23.73 (2.20) 12.70 (1.18) 5.51 (0.51) 12.61 (1.17) 42 1/2"(1080) 30.98 (2.88) 9040 ◊7.30 (0.68) 23 7/8"(607) 44"(1118) 27.77 (2.58) 14.86 (1.38) 6.45 (0.60) 14.60 (1.36) 36 1/2"(927) 35.46 (3.29) 9046 ◊8.30 (0.77) 23 7/8"(607) 50"(1270) 31.81 (2.95) 17.02 (1.58) 7.39 (0.69) 16.60 (1.54) 30 1/2"(775) 39.94 (3.71) 9050 ◊9.29 (0.86) 23 7/8"(607) 56"(1422) 35.84 (3.33) 19.19 (1.78) 8.33 (0.77) 18.59 (1.73) 24 1/2"(622) 44.42 (4.13) 9056 ◊10.29 (0.96) 23 7/8"(607) 62"(1575) 39.88 (3.71) 21.35 (1.98) 9.27 (0.86) 20.58 (1.91) 18 1/2"(470) 48.90 (4.54) 9060 ◊11.29 (1.05) 23 7/8"(607) 68"(1727) 43.92 (4.08) 23.51 (2.18) 10.21 (0.95) 22.57 (2.10) 12 1/2"(318) 53.38 (4.96) 10016 2.62 (0.24) 26 7/8"(683) 14"(356) 8.51 (0.79) 4.52 (0.42) 1.99 (0.19) 5.23 (0.49) 66 1/2"(1689) 14.52 (1.35) 10020 3.74 (0.35) 26 7/8"(683) 20"(508) 13.05 (1.21) 6.93 (0.64) 3.06 (0.28) 7.47 (0.69) 60 1/2"(1537) 19.50 (1.81) 10026 4.86 (0.45) 26 7/8"(683) 26"(660) 17.59 (1.63) 9.35 (0.87) 4.12 (0.38) 9.71 (0.90) 54 1/2"(1384) 24.48 (2.27) 10030 5.98 (0.56) 26 7/8"(683) 32"(813) 22.13 (2.06) 11.76 (1.09) 5.18 (0.48) 11.96 (1.11) 48 1/2"(1232) 29.46 (2.74) 10036 ◊7.10 (0.66) 26 7/8"(683) 38"(965) 26.67 (2.48) 14.17 (1.32) 6.25 (0.58) 14.20 (1.32) 42 1/2"(1080) 34.44 (3.20) 10040 ◊8.22 (0.76) 26 7/8"(683) 44"(1118) 31.20 (2.90) 16.58 (1.54) 7.31 (0.68) 16.44 (1.53) 36 1/2"(927) 39.42 (3.66) 10046 ◊9.34 (0.87) 26 7/8"(683) 50"(1270) 35.74 (3.32) 18.99 (1.76) 8.38 (0.78) 18.68 (1.74) 30 1/2"(775) 44.40 (4.12) 10050 ◊10.46 (0.97) 26 7/8"(683) 56"(1422) 40.28 (3.74) 21.40 (1.99) 9.44 (0.88) 20.92 (1.94) 24 1/2"(622) 49.38 (4.59) 10056 ◊11.58 (1.08) 26 7/8"(683) 62"(1575) 44.82 (4.16) 23.82 (2.21) 10.50 (0.98) 23.16 (2.15) 18 1/2"(470) 54.36 (5.05) 10060 ◊12.70 (1.18) 26 7/8"(683) 68"(1727) 49.36 (4.59) 26.23 (2.44) 11.57 (1.07) 25.40 (2.36) 12 1/2"(318) 59.34 (5.51) 11016 2.91 (0.27) 29 7/8"(759) 14"(356) 9.45 (0.88) 4.99 (0.46) 2.23 (0.21) 5.81 (0.54) 66 1/2"(1689) 15.98 (1.48) 11020 4.15 (0.39) 29 7/8"(759) 20"(508) 14.49 (1.35) 7.65 (0.71) 3.42 (0.32) 8.31 (0.77) 60 1/2"(1537) 21.46 (1.99) 11026 5.40 (0.50) 29 7/8"(759) 26"(660) 19.53 (1.81) 10.31 (0.96) 4.61 (0.43) 10.80 (1.00) 54 1/2"(1384) 26.94 (2.50) 11030 ◊6.64 (0.62) 29 7/8"(759) 32"(813) 24.56 (2.28) 12.98 (1.21) 5.79 (0.54) 13.29 (1.23) 48 1/2"(1232) 32.42 (3.01) 11036 ◊7.89 (0.73) 29 7/8"(759) 38"(965) 29.60 (2.75) 15.64 (1.45) 6.98 (0.65) 15.78 (1.47) 42 1/2"(1080) 37.90 (3.52) 11040 ◊9.14 (0.85) 29 7/8"(759) 44"(1118) 34.64 (3.22) 18.30 (1.70) 8.17 (0.76) 18.27 (1.70) 36 1/2"(927) 43.38 (4.03) 11046 ◊10.38 (0.96) 29 7/8"(759) 50"(1270) 39.68 (3.69) 20.96 (1.95) 9.36 (0.87) 20.76 (1.93) 30 1/2"(775) 48.86 (4.54) 11050 ◊11.63 (1.08) 29 7/8"(759) 56"(1422) 44.72 (4.15) 23.62 (2.19) 10.55 (0.98) 23.25 (2.16) 24 1/2"(622) 54.34 (5.05) 11056 ◊12.87 (1.20) 29 7/8"(759) 62"(1575) 49.76 (4.62) 26.28 (2.44) 11.74 (1.09) 25.75 (2.39) 18 1/2"(470) 59.81 (5.56) 11060 ◊14.12 (1.31) 29 7/8"(759) 68"(1727) 54.80 (5.09) 28.95 (2.69) 12.92 (1.20) 28.24 (2.62) 12 1/2"(318) 65.29 (6.07) 12016 3.20 (0.30) 32 7/8"(836) 14"(356) 10.39 (0.96) 5.46 (0.51) 2.46 (0.23) 6.40 (0.59) 66 1/2"(1689) 17.44 (1.62) 12020 4.57 (0.42) 32 7/8"(836) 20"(508) 15.92 (1.48) 8.37 (0.78) 3.78 (0.35) 9.14 (0.85) 60 1/2"(1537) 23.42 (2.18) 12026 ◊5.94 (0.55) 32 7/8"(836) 26"(660) 21.46 (1.99) 11.28 (1.05) 5.09 (0.47) 11.88 (1.10) 54 1/2"(1384) 29.40 (2.73) 12030 ◊7.31 (0.68) 32 7/8"(836) 32"(813) 27.00 (2.51) 14.19 (1.32) 6.40 (0.59) 14.62 (1.36) 48 1/2"(1232) 35.38 (3.29) 12036 ◊8.68 (0.81) 32 7/8"(836) 38"(965) 32.54 (3.02) 17.11 (1.59) 7.72 (0.72) 17.36 (1.61) 42 1/2"(1080) 41.36 (3.84) 12040 ◊10.05 (0.93) 32 7/8"(836) 44"(1118) 38.08 (3.54) 20.02 (1.86) 9.03 (0.84) 20.10 (1.87) 36 1/2"(927) 47.34 (4.40) 12046 ◊11.42 (1.06) 32 7/8"(836) 50"(1270) 43.62 (4.05) 22.93 (2.13) 10.34 (0.96) 22.85 (2.12) 30 1/2"(775) 53.31 (4.95) 12050 ◊12.79 (1.19) 32 7/8"(836) 56"(1422) 49.16 (4.57) 25.84 (2.40) 11.66 (1.08) 25.59 (2.38) 24 1/2"(622) 59.29 (5.51) 12056 ◊14.16 (1.32) 32 7/8"(836) 62"(1575) 54.70 (5.08) 28.75 (2.67) 12.97 (1.21) 28.33 (2.63) 18 1/2"(470) 65.27 (6.06) 12060 ◊15.54 (1.44) 32 7/8"(836) 68"(1727) 60.23 (5.60) 31.67 (2.94) 14.28 (1.33) 31.07 (2.89) 12 1/2"(318) 71.25 (6.62) (continued) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 63 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES continued on next page Gliding Active-Stationary-Active 1:1:1 Sash Ratio Window Opening and Area Specification Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Total Glass Area Sq. Ft./(m2) Fixed Sash Glass Area Sq. Ft./(m2) Single Active Sash Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2) Width Inches/(mm) Height Inches/(mm) 4016 1.04 (0.10)10 5/8"(271) 14"(356) 2.89 (0.27) 0.96 (0.09) 0.96 (0.09) 2.07 (0.19)66 1/2"(1689) 5.77 (0.54) 4020 1.48 (0.14)10 5/8"(271) 20"(508) 4.42 (0.41) 1.48 (0.14) 1.47 (0.14) 2.96 (0.28)60 1/2"(1537) 7.75 (0.72) 4026 1.93 (0.18)10 5/8"(271) 26"(660) 5.96 (0.55) 1.99 (0.19) 1.99 (0.18) 3.85 (0.36)54 1/2"(1384) 9.73 (0.90) 4030 2.37 (0.22)10 5/8"(271) 32"(813) 7.50 (0.70) 2.51 (0.23) 2.50 (0.23) 4.74 (0.44)48 1/2"(1232) 11.71 (1.09) 4036 2.82 (0.26)10 5/8"(271) 38"(965) 9.04 (0.84) 3.02 (0.28) 3.01 (0.28) 5.63 (0.52)42 1/2"(1080) 13.69 (1.27) 4040 3.26 (0.30)10 5/8"(271) 44"(1118) 10.58 (0.98) 3.53 (0.33) 3.52 (0.33) 6.52 (0.61)36 1/2"(927) 15.67 (1.46) 4046 3.70 (0.34)10 5/8"(271) 50"(1270) 12.12 (1.13) 4.05 (0.38) 4.03 (0.37) 7.41 (0.69)30 1/2"(775) 17.65 (1.64) 4050 4.15 (0.39)10 5/8"(271) 56"(1422) 13.66 (1.27) 4.56 (0.42) 4.55 (0.42) 8.30 (0.77)24 1/2"(622) 19.63 (1.82) 4056 4.59 (0.43)10 5/8"(271) 62"(1575) 15.20 (1.41) 5.08 (0.47) 5.06 (0.47) 9.19 (0.85)18 1/2"(470) 21.61 (2.01) 4060 5.04 (0.47)10 5/8"(271) 68"(1727) 16.73 (1.55) 5.59 (0.52) 5.57 (0.52) 10.08 (0.94)12 1/2"(318) 23.59 (2.19) 5016 1.43 (0.13)14 5/8"(373) 14"(356) 3.82 (0.36) 1.28 (0.12) 1.27 (0.12) 2.85 (0.26)66 1/2"(1689) 7.23 (0.67) 5020 2.04 (0.19)14 5/8"(373) 20"(508) 5.86 (0.54) 1.96 (0.18) 1.95 (0.18) 4.07 (0.38)60 1/2"(1537) 9.71 (0.90) 5026 2.65 (0.25)14 5/8"(373) 26"(660) 7.90 (0.73) 2.64 (0.25) 2.63 (0.24) 5.30 (0.49)54 1/2"(1384) 12.19 (1.13) 5030 3.26 (0.30)14 5/8"(373) 32"(813) 9.94 (0.92) 3.32 (0.31) 3.31 (0.31) 6.52 (0.61)48 1/2"(1232) 14.67 (1.36) 5036 3.87 (0.36)14 5/8"(373) 38"(965) 11.98 (1.11) 4.00 (0.37) 3.99 (0.37) 7.74 (0.72)42 1/2"(1080) 17.15 (1.59) 5040 4.48 (0.42)14 5/8"(373) 44"(1118) 14.02 (1.30) 4.68 (0.43) 4.67 (0.43) 8.96 (0.83)36 1/2"(927) 19.63 (1.82) 5046 5.09 (0.47)14 5/8"(373) 50"(1270) 16.06 (1.49) 5.36 (0.50) 5.35 (0.50) 10.19 (0.95)30 1/2"(775) 22.11 (2.05) 5050 5.70 (0.53)14 5/8"(373) 56"(1422) 18.09 (1.68) 6.04 (0.56) 6.03 (0.56) 11.41 (1.06)24 1/2"(622) 24.59 (2.28) 5056 6.32 (0.59)14 5/8"(373) 62"(1575) 20.13 (1.87) 6.72 (0.62) 6.71 (0.62) 12.63 (1.17)18 1/2"(470) 27.06 (2.51) 5060 6.93 (0.64)14 5/8"(373) 68"(1727) 22.17 (2.06) 7.40 (0.69) 7.38 (0.69) 13.85 (1.29)12 1/2"(318) 29.54 (2.74) 6016 1.82 (0.17)18 5/8"(474) 14"(356) 4.76 (0.44) 1.59 (0.15) 1.59 (0.15) 3.63 (0.34)66 1/2"(1689) 8.69 (0.81) 6020 2.59 (0.24)18 5/8"(474) 20"(508) 7.30 (0.68) 2.44 (0.23) 2.43 (0.23) 5.19 (0.48)60 1/2"(1537) 11.67 (1.08) 6026 3.37 (0.31)18 5/8"(474) 26"(660) 9.84 (0.91) 3.28 (0.31) 3.28 (0.30) 6.74 (0.63)54 1/2"(1384) 14.65 (1.36) 6030 4.15 (0.39)18 5/8"(474) 32"(813) 12.38 (1.15) 4.13 (0.38) 4.12 (0.38) 8.30 (0.77)48 1/2"(1232) 17.63 (1.64) 6036 4.93 (0.46)18 5/8"(474) 38"(965) 14.92 (1.39) 4.98 (0.46) 4.97 (0.46) 9.85 (0.92)42 1/2"(1080) 20.61 (1.91) 6040 5.70 (0.53)18 5/8"(474) 44"(1118) 17.45 (1.62) 5.83 (0.54) 5.81 (0.54) 11.41 (1.06)36 1/2"(927) 23.59 (2.19) 6046 6.48 (0.60)18 5/8"(474) 50"(1270) 19.99 (1.86) 6.67 (0.62) 6.66 (0.62) 12.96 (1.20)30 1/2"(775) 26.56 (2.47) 6050 7.26 (0.67)18 5/8"(474) 56"(1422) 22.53 (2.09) 7.52 (0.70) 7.51 (0.70) 14.52 (1.35)24 1/2"(622) 29.54 (2.74) 6056 8.04 (0.75)18 5/8"(474) 62"(1575) 25.07 (2.33) 8.37 (0.78) 8.35 (0.78) 16.08 (1.49)18 1/2"(470) 32.52 (3.02) 6060 8.82 (0.82)18 5/8"(474) 68"(1727) 27.61 (2.56) 9.22 (0.86) 9.20 (0.85) 17.63 (1.64)12 1/2"(318) 35.50 (3.30) 7016 2.20 (0.20)22 5/8"(576) 14"(356) 5.70 (0.53) 1.90 (0.18) 1.90 (0.18) 4.41 (0.41)66 1/2"(1689) 10.15 (0.94) 7020 3.15 (0.29)22 5/8"(576) 20"(508) 8.74 (0.81) 2.92 (0.27) 2.91 (0.27) 6.30 (0.59)60 1/2"(1537) 13.63 (1.27) 7026 4.09 (0.38)22 5/8"(576) 26"(660) 11.78 (1.09) 3.93 (0.37) 3.92 (0.36) 8.19 (0.76)54 1/2"(1384) 17.11 (1.59) 7030 5.04 (0.47)22 5/8"(576) 32"(813) 14.81 (1.38) 4.94 (0.46) 4.94 (0.46) 10.08 (0.94)48 1/2"(1232) 20.59 (1.91) 7036 ◊5.98 (0.56)22 5/8"(576) 38"(965) 17.85 (1.66) 5.96 (0.55) 5.95 (0.55) 11.96 (1.11)42 1/2"(1080) 24.06 (2.24) 7040 ◊6.93 (0.64)22 5/8"(576) 44"(1118) 20.89 (1.94) 6.97 (0.65) 6.96 (0.65) 13.85 (1.29)36 1/2"(927) 27.54 (2.56) 7046 ◊7.87 (0.73)22 5/8"(576) 50"(1270) 23.93 (2.22) 7.99 (0.74) 7.97 (0.74) 15.74 (1.46)30 1/2"(775) 31.02 (2.88) 7050 ◊8.82 (0.82)22 5/8"(576) 56"(1422) 26.97 (2.51) 9.00 (0.84) 8.98 (0.83) 17.63 (1.64)24 1/2"(622) 34.50 (3.21) 7056 ◊9.76 (0.91)22 5/8"(576) 62"(1575) 30.01 (2.79) 10.01 (0.93) 10.00 (0.93) 19.52 (1.81)18 1/2"(470) 37.98 (3.53) 7060 ◊10.70 (0.99)22 5/8"(576) 68"(1727) 33.05 (3.07) 11.03 (1.02) 11.01 (1.02) 21.41 (1.99)12 1/2"(318) 41.46 (3.85) 7616 2.40 (0.22)24 5/8"(627) 14"(356) 6.17 (0.57) 2.06 (0.19) 2.05 (0.19) 4.80 (0.45)66 1/2"(1689) 10.88 (1.01) 7620 3.43 (0.32)24 5/8"(627) 20"(508) 9.46 (0.88) 3.15 (0.29) 3.15 (0.29) 6.85 (0.64)60 1/2"(1537) 14.61 (1.36) 7626 4.45 (0.41)24 5/8"(627) 26"(660) 12.74 (1.18) 4.25 (0.40) 4.25 (0.39) 8.91 (0.83)54 1/2"(1384) 18.34 (1.70) 7630 5.48 (0.51)24 5/8"(627) 32"(813) 16.03 (1.49) 5.35 (0.50) 5.34 (0.50) 10.96 (1.02)48 1/2"(1232) 22.06 (2.05) 7636 ◊6.51 (0.60)24 5/8"(627) 38"(965) 19.32 (1.80) 6.45 (0.60) 6.44 (0.60) 13.02 (1.21)42 1/2"(1080) 25.79 (2.40) 7640 ◊7.54 (0.70)24 5/8"(627) 44"(1118) 22.61 (2.10) 7.54 (0.70) 7.53 (0.70) 15.08 (1.40)36 1/2"(927) 29.52 (2.74) 7646 ◊8.57 (0.80)24 5/8"(627) 50"(1270) 25.90 (2.41) 8.64 (0.80) 8.63 (0.80) 17.13 (1.59)30 1/2"(775) 33.25 (3.09) 7650 ◊9.59 (0.89)24 5/8"(627) 56"(1422) 29.19 (2.71) 9.74 (0.90) 9.72 (0.90) 19.19 (1.78)24 1/2"(622) 36.98 (3.44) 7656 ◊10.62 (0.99)24 5/8"(627) 62"(1575) 32.48 (3.02) 10.84 (1.01) 10.82 (1.01) 21.24 (1.97)18 1/2"(470) 40.71 (3.78) 7660 ◊11.65 (1.08)24 5/8"(627) 68"(1727) 35.77 (3.32) 11.93 (1.11) 11.92 (1.11) 23.30 (2.16)12 1/2"(318) 44.44 (4.13) 8016 2.59 (0.24)26 5/8"(677) 14"(356) 6.64 (0.62) 2.21 (0.21) 2.21 (0.21) 5.19 (0.48)66 1/2"(1689) 11.61 (1.08) 8020 3.70 (0.34)26 5/8"(677) 20"(508) 10.17 (0.95) 3.39 (0.32) 3.39 (0.31) 7.41 (0.69)60 1/2"(1537) 15.59 (1.45) 8026 4.82 (0.45)26 5/8"(677) 26"(660) 13.71 (1.27) 4.58 (0.43) 4.57 (0.42) 9.63 (0.89)54 1/2"(1384) 19.56 (1.82) 8030 ◊5.93 (0.55)26 5/8"(677) 32"(813) 17.25 (1.60) 5.76 (0.53) 5.75 (0.53) 11.85 (1.10)48 1/2"(1232) 23.54 (2.19) 8036 ◊7.04 (0.65)26 5/8"(677) 38"(965) 20.79 (1.93) 6.94 (0.64) 6.93 (0.64) 14.08 (1.31)42 1/2"(1080) 27.52 (2.56) 8040 ◊8.15 (0.76)26 5/8"(677) 44"(1118) 24.33 (2.26) 8.12 (0.75) 8.11 (0.75) 16.30 (1.51)36 1/2"(927) 31.50 (2.93) 8046 ◊9.26 (0.86)26 5/8"(677) 50"(1270) 27.87 (2.59) 9.30 (0.86) 9.28 (0.86) 18.52 (1.72)30 1/2"(775) 35.48 (3.30) 8050 ◊10.37 (0.96)26 5/8"(677) 56"(1422) 31.41 (2.92) 10.48 (0.97) 10.46 (0.97) 20.74 (1.93)24 1/2"(622) 39.46 (3.67) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 64 GLIDING WINDOWS Gliding Active-Stationary-Active 1:1:1 Sash Ratio Window Opening and Area Specification Window Number Clear Opening Area Sq. Ft./(m2) Clear Opening in Full Open Position Total Glass Area Sq. Ft./(m2) Fixed Sash Glass Area Sq. Ft./(m2) Single Active Sash Glass Area Sq. Ft./(m2) Vent Area Sq. Ft./(m2) Top of Subfloor to Top of Inside Sill Stop Inches/(mm) Overall Window Area Sq. Ft./(m2)Width Inches/(mm) Height Inches/(mm) 8056 ◊11.48 (1.07)26 5/8"(677) 62"(1575) 34.95 (3.25) 11.66 (1.08) 11.64 (1.08) 22.97 (2.13)18 1/2"(470) 43.44 (4.04) 8060 ◊12.59 (1.17)26 5/8"(677) 68"(1727) 38.48 (3.58) 12.84 (1.19) 12.82 (1.19) 25.19 (2.34)12 1/2"(318) 47.42 (4.41) 8616 2.79 (0.26)28 5/8"(728) 14"(356) 7.10 (0.66) 2.37 (0.22) 2.37 (0.22) 5.57 (0.52) 66 1/2"(1689) 12.34 (1.15) 8620 3.98 (0.37)28 5/8"(728) 20"(508) 10.89 (1.01) 3.63 (0.34) 3.63 (0.34) 7.96 (0.74) 60 1/2"(1537) 16.56 (1.54) 8626 5.18 (0.48)28 5/8"(728) 26"(660) 14.68 (1.36) 4.90 (0.46) 4.89 (0.45) 10.35 (0.96) 54 1/2"(1384) 20.79 (1.93) 8630 ◊6.37 (0.59)28 5/8"(728) 32"(813) 18.47 (1.72) 6.16 (0.57) 6.15 (0.57) 12.74 (1.18) 48 1/2"(1232) 25.02 (2.32) 8636 ◊7.57 (0.70)28 5/8"(728) 38"(965) 22.26 (2.07) 7.43 (0.69) 7.42 (0.69) 15.13 (1.41) 42 1/2"(1080) 29.25 (2.72) 8640 ◊8.76 (0.81)28 5/8"(728) 44"(1118) 26.05 (2.42) 8.69 (0.81) 8.68 (0.81) 17.52 (1.63) 36 1/2"(927) 33.48 (3.11) 8646 ◊9.95 (0.92)28 5/8"(728) 50"(1270) 29.84 (2.77) 9.95 (0.92) 9.94 (0.92) 19.91 (1.85) 30 1/2"(775) 37.71 (3.50) 8650 ◊11.15 (1.04)28 5/8"(728) 56"(1422) 33.63 (3.12) 11.22 (1.04) 11.20 (1.04) 22.30 (2.07) 24 1/2"(622) 41.94 (3.90) 8656 ◊12.34 (1.15)28 5/8"(728) 62"(1575) 37.41 (3.48) 12.48 (1.16) 12.47 (1.16) 24.69 (2.29) 18 1/2"(470) 46.17 (4.29) 8660 ◊13.54 (1.26)28 5/8"(728) 68"(1727) 41.20 (3.83) 13.75 (1.28) 13.73 (1.28) 27.08 (2.52) 12 1/2"(318) 50.40 (4.68) Number of lights and overall pattern varies with window size. Patterns may not be available in all configurations or sizes. Specified equal light and custom patterns are also available. For specified equal light, specify number of same-size rectangles across or down. For more grille options, see page 14 or visit andersenwindows.com/grilles. Prairie A Colonial Colonial Fractional Fractional Modied Tall Short Grille Patterns Gliding Custom ExampleSpecied Equal Light Examples (continued) • Top of Subfloor to Top of Inside Sill Stop is calculated based upon a structural header height of 6'-10 1/2" (2096). • Dimensions in parentheses are in millimeters or square meters. ◊ Meets or exceeds clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). 65 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES Gliding Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. Vertical Section Vertical Section Stucco Exterior Horizontal Section Stucco Exterior Horizontal Section 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1 3 ⁄8" (35) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 1 ⁄4" (6 ) Low-E Glass sill head Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1" (25) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 1 ⁄8" (3 ) 3 1 ⁄8" (7 9 ) 1 ⁄ 8" (3 ) 1 ⁄4" (6 ) Low-E Glass sill head Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen (79)(79) Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstructed Glass1 3 ⁄ 8" (3 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) (56) 2 3 ⁄16"3 1 ⁄8"Unobstructed Glass jambjamb meeting stile Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) Clear Opening 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) (79)(79) Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstructed Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) (56) 2 3 ⁄16"3 1 ⁄8"Unobstructed Glass Low-E Glass Insect Screen jambjamb meeting stile 1 3 ⁄4" (44) Clear Opening 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y Vertical Section Picture Over Gliding 6 3 ⁄4" (1 7 1 ) 3 7⁄ 8" (9 8 ) In t e g r a l See pages 88-93 for joining details. 66 GLIDING WINDOWS Vertical Section Existing Framed Opening Horizontal Section Existing Framed Opening sill head Andersen® Extension Jamb Attachment Flange (optional) 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Low-E Glass Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen (79)(79) Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstructed Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) (56) 2 3 ⁄16"3 1 ⁄8"Unobstructed Glass jambjamb meeting stile Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) Clear Opening Gliding Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 No F l a n g e In s e r t Vertical Section Existing Window Opening Horizontal Section Existing Window Opening 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Ex i s t i n g O p e n i n g Un o b s t r . Gl a s s 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 3 1 ⁄4" (83) 1 ⁄4" (6 ) Low-E Glass Andersen® Exterior Sill Extender Trim (optional) sill head Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Clear Opening 3 1 ⁄4" (8 3 ) (79)(79) Window Dimension Width Existing Opening 3 1 ⁄8"Unobstructed Glass 1 ⁄4" (6) 1 ⁄4" (6) (56) 2 3 ⁄16"3 1 ⁄8"Unobstructed Glass Low-E Glass jamb Insect Screen jambjamb meeting stile 1 3 ⁄4" (44) Clear Opening Integral detail shown on previous page. Installation accessories are available for insert and flush fin frames; see page 120. See pages 88-93 for joining details. • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Fl u s h F i n * Horizontal Section Existing Aluminum Frame Window Opening Vertical Section Existing Aluminum Frame Window Opening sill head 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 3 ⁄16 " (5 ) 3 1 ⁄8" (7 9 ) 3 ⁄16 " (5 ) 1 5 ⁄ 8" (4 1 ) 3 ⁄8" (10) 1 5 ⁄ 8" (4 1 ) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) 1 3 ⁄8" (35) Low-E Glass Andersen® Interior Flat Trim Insect Screen (79)(79) Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstructed Glass (56) 2 3 ⁄16"3 1 ⁄8"Unobstructed Glass 3 ⁄16" (5) 3 ⁄16" (5) 1 5 ⁄8" (41) 1 5 ⁄8" (41) jamb jamb meeting stile 1 3 ⁄4" (44) Clear Opening 3 1 ⁄4" (8 3 ) 3 ⁄ 8" (1 0 ) Low-E Glass Andersen® Interior Flat Trim 67 10 0 S e r i e s G l i d i n g Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. 2616 30161616 2016 2620 30201620 2020 2630 303020301630 3616 3620 3630 4016 4020 4030 2610 30101610 2010 3610 4010 1016 1020 1030 50104610 5610 50164616 5616 50204620 5620 50304630 5630 1010 2636 303620361636 3636 40361036 50364636 5636 2640 3040204016401040 4640 5640 2626 302620261626 3626 40261026 50264626 5626 3640 4040 5040 2646 304620461646 3646 40461046 50464646 5646 2650 305020501650 3650 40501050 50504650 5650 2656 305620561656 3656 40561056 50564656 5656 2660 306020601660 3660 40601060 50604660 5660 2666 306620661666 3666 40661066 50664666 5666 Window Dimension Unobstructed Glass Minimum Rough Opening Table of Picture and Transom Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" CU S T O M H E I G H T S — 11 1 ⁄2" t o 95 1 ⁄2" 11 1/4" 1'-5 1/2" 1'-6" 5 1/4" 11 1/2" 1'-0" 17 1/4" 1'-11 1/2" 2'-0" 4'-5 1/2" 4'-6" 47 1/4"53 1/4" 4'-11 1/2" 5'-0" 59 1/4" 5'-5 1/2" 5'-6" 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" CUSTOM WIDTHS — 11 1 ⁄2" to 95 1 ⁄2" 11 1/4" 1' - 5 1/2" 1' - 6 " 5 1/4" 11 1/2" 1' - 0 " 17 1/4" 1' - 1 1 1/2" 2' - 0 " 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 5' - 5 1/2" 5' - 6 " 59 1/4" 5' - 1 1 1/2" 6' - 0 " 65 1/4" 6' - 5 1/2" 6' - 6 " 71 1/4" (749) (762) (591) (902) (914) (743) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (292) (305) (133) (597) (610) (438) (1359) (1372) (1200) (1511) (1524) (1353) (1664) (1676) (1505) (12 0 7 ) (12 1 9 ) (10 4 8 ) (10 5 4 ) (10 6 7 ) (89 5 ) (2 9 2 ) (30 5 ) (59 1 ) (4 4 5 ) (45 7 ) (28 6 ) (5 9 7 ) (61 0 ) (43 8 ) (16 6 4 ) (16 7 6 ) (15 0 5 ) (18 1 6 ) (18 2 9 ) (16 5 7 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (19 6 9 ) (19 8 1 ) (18 1 0 ) Notes on next page also apply to this page. 68 PICTURE, TRANSOM & SPECIALTY WINDOWS 6010 6016 6020 6030 6610 6616 6620 6626 6630 7010 7016 7020 7026 7030 7610 7616 7620 7626 7630 8010 8016 8020 8026 8030 6036 6636 7036 7636 8036 6040 6640 7040 7640 8040 6026 6046 6646 7046 7646 8046 6050 6650 7050 7650 8050 6056 6656 7056 7656 8056 6060 6660 7060 7660 8060 6066 6'-0" 5'-11 1/2" 65 1/4"71 1/4" 6'-5 1/2" 6'-6" 77 1/4" 6'-11 1/2" 7'-0" 83 1/4" 7'-5 1/2" 7'-6" 89 1/4" 7'-11 1/2" 8'-0" (1816) (1829) (1657) (1969) (1981) (1810) (2121) (2134) (1962) (2273) (2286) (2115) (2426) (2438) (2267) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Custom-size windows are available in 1 ⁄8" (3) increments. See page 98 for custom sizes and specifications. Grille patterns shown on page 79. Details shown on pages 83-86. continued on next page 69 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES 2670 307020701670 3670 40701070 50704670 5670 2676 307620761676 3676 40761076 50764676 5676 2680 308020801680 3680 40801080 50804680 5680 Window Dimension Unobstructed Glass Minimum Rough Opening Table of Picture and Transom Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 2'-5 1/2" 2'-6" 23 1/4" 29 1/4" 2'-11 1/2" 3'-0" 41 1/4" 3'-11 1/2" 4'-0" 35 1/4" 3'-5 1/2" 3'-6" CU S T O M H E I G H T S — 11 1 ⁄ 2" t o 95 1 ⁄ 2" 11 1/4" 1'-5 1/2" 1'-6" 5 1/4" 11 1/2" 1'-0" 17 1/4" 1'-11 1/2" 2'-0" 4'-5 1/2" 4'-6" 47 1/4"53 1/4" 4'-11 1/2" 5'-0" 59 1/4" 5'-5 1/2" 5'-6" 7' - 5 1/2" 7' - 6 " 83 1/4" 7' - 0 " 6' - 1 1 1/2" 77 1/4" 7' - 1 1 1/2" 8' - 0 " 89 1/4" CUSTOM WIDTHS — 11 1 ⁄2" to 95 1 ⁄2" (749) (762) (591) (902) (914) (743) (1207) (1219) (1048) (1054) (1067) (895) (445) (457) (286) (292) (305) (133) (597) (610) (438) (1359) (1372) (1200) (1511) (1524) (1353) (1664) (1676) (1505) (22 7 3 ) (22 8 6 ) (21 1 5 ) (2 1 2 1 ) (21 3 4 ) (19 6 2 ) (24 2 6 ) (24 3 8 ) (22 6 7 ) (continued) Picture and Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1010 0.19 (0.02) 0.92 (0.09) 1016 0.41 (0.04) 1.40 (0.13) 1020 0.63 (0.06) 1.88 (0.17) 1026 0.85 (0.08) 2.36 (0.22) 1030 1.07 (0.10) 2.84 (0.26) 1036 1.29 (0.12) 3.31 (0.31) 1040 1.50 (0.14) 3.79 (0.35) 1046 1.72 (0.16) 4.27 (0.40) 1050 1.94 (0.18) 4.75 (0.44) 1056 2.16 (0.20) 5.23 (0.49) 1060 2.38 (0.22) 5.71 (0.53) 1066 2.60 (0.24) 6.19 (0.57) 1070 2.82 (0.26) 6.67 (0.62) 1076 3.04 (0.28) 7.15 (0.66) 1080 3.25 (0.30) 7.63 (0.71) 1610 0.41 (0.04) 1.40 (0.13) 1616 0.88 (0.08) 2.13 (0.20) 1620 1.35 (0.13) 2.86 (0.27) 1626 1.82 (0.17) 3.59 (0.33) 1630 2.29 (0.21) 4.31 (0.40) 1636 2.75 (0.26) 5.04 (0.47) 1640 3.22 (0.30) 5.77 (0.54) 1646 3.69 (0.34) 6.50 (0.60) Picture and Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 2616 1.82 (0.17) 3.59 (0.33) 2620 2.79 (0.26) 4.81 (0.45) 2626 3.75 (0.35) 6.04 (0.56) 2630 4.72 (0.44) 7.27 (0.68) 2636 5.69 (0.53) 8.50 (0.79) 2640 6.66 (0.62) 9.73 (0.90) 2646 7.63 (0.71) 10.96 (1.02) 2650 8.60 (0.80) 12.19 (1.13) 2656 9.57 (0.89) 13.42 (1.25) 2660 10.54 (0.98) 14.65 (1.36) 2666 11.50 (1.07) 15.88 (1.47) 2670 12.47 (1.16) 17.11 (1.59) 2676 13.44 (1.25) 18.34 (1.70) 2680 14.41 (1.34) 19.56 (1.82) 3010 1.07 (0.10) 2.84 (0.26) 3016 2.29 (0.21) 4.31 (0.40) 3020 3.50 (0.33) 5.79 (0.54) 3026 4.72 (0.44) 7.27 (0.68) 3030 5.94 (0.55) 8.75 (0.81) 3036 7.16 (0.67) 10.23 (0.95) 3040 8.38 (0.78) 11.71 (1.09) Picture and Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1650 4.16 (0.39) 7.23 (0.67) 1656 4.63 (0.43) 7.96 (0.74) 1660 5.10 (0.47) 8.69 (0.81) 1666 5.57 (0.52) 9.42 (0.87) 1670 6.04 (0.56) 10.15 (0.94) 1676 6.50 (0.60) 10.88 (1.01) 1680 6.97 (0.65) 11.61 (1.08) 2010 0.63 (0.06) 1.88 (0.17) 2016 1.35 (0.13) 2.86 (0.27) 2020 2.07 (0.19) 3.84 (0.36) 2026 2.79 (0.26) 4.81 (0.45) 2030 3.50 (0.33) 5.79 (0.54) 2036 4.22 (0.39) 6.77 (0.63) 2040 4.94 (0.46) 7.75 (0.72) 2046 5.66 (0.53) 8.73 (0.81) 2050 6.38 (0.59) 9.71 (0.90) 2056 7.10 (0.66) 10.69 (0.99) 2060 7.82 (0.73) 11.67 (1.08) 2066 8.54 (0.79) 12.65 (1.17) 2070 9.25 (0.86) 13.63 (1.27) 2076 9.97 (0.93) 14.61 (1.36) 2080 10.69 (0.99) 15.59 (1.45) 2610 0.85 (0.08) 2.36 (0.22) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. • Dimensions in parentheses are in square meters. continued on next page Notes on next page also apply to this page. 70 PICTURE, TRANSOM & SPECIALTY WINDOWS Custom-size windows are available in 1 ⁄8" (3) increments. See page 98 for custom sizes and specifications. Grille patterns shown on page 79. Details shown on pages 83-86. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. 6070 6076 6080 6'-0" 5'-11 1/2" 65 1/4" (1816) (1829) (1657) Picture and Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 3046 9.60 (0.89) 13.19 (1.23) 3050 10.82 (1.00) 14.67 (1.36) 3056 12.04 (1.12) 16.15 (1.50) 3060 13.25 (1.23) 17.63 (1.64) 3066 14.47 (1.34) 19.11 (1.77) 3070 15.69 (1.46) 20.59 (1.91) 3076 16.91 (1.57) 22.06 (2.05) 3080 18.13 (1.68) 23.54 (2.19) 3610 1.29 (0.12) 3.31 (0.31) 3616 2.75 (0.26) 5.04 (0.47) 3620 4.22 (0.39) 6.77 (0.63) 3626 5.69 (0.53) 8.50 (0.79) 3630 7.16 (0.67) 10.23 (0.95) 3636 8.63 (0.80) 11.96 (1.11) 3640 10.10 (0.94) 13.69 (1.27) 3646 11.57 (1.07) 15.42 (1.43) 3650 13.04 (1.21) 17.15 (1.59) 3656 14.50 (1.35) 18.88 (1.75) 3660 15.97 (1.48) 20.61 (1.91) 3666 17.44 (1.62) 22.34 (2.07) 3670 18.91 (1.76) 24.06 (2.24) 3676 20.38 (1.89) 25.79 (2.40) 3680 21.85 (2.03) 27.52 (2.56) Picture and Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 4010 1.50 (0.14) 3.79 (0.35) 4016 3.22 (0.30) 5.77 (0.54) 4020 4.94 (0.46) 7.75 (0.72) 4026 6.66 (0.62) 9.73 (0.90) 4030 8.38 (0.78) 11.71 (1.09) 4036 10.10 (0.94) 13.69 (1.27) 4040 11.82 (1.10) 15.67 (1.46) 4046 13.54 (1.26) 17.65 (1.64) 4050 15.25 (1.42) 19.63 (1.82) 4056 16.97 (1.58) 21.61 (2.01) 4060 18.69 (1.74) 23.59 (2.19) 4066 20.41 (1.90) 25.56 (2.37) 4070 22.13 (2.06) 27.54 (2.56) 4076 23.85 (2.22) 29.52 (2.74) 4080 25.57 (2.38) 31.50 (2.93) 4610 1.72 (0.16) 4.27 (0.40) 4616 3.69 (0.34) 6.50 (0.60) 4620 5.66 (0.53) 8.73 (0.81) 4626 7.63 (0.71) 10.96 (1.02) 4630 9.60 (0.89) 13.19 (1.23) 4636 11.57 (1.07) 15.42 (1.43) 4640 13.54 (1.26) 17.65 (1.64) 4646 15.50 (1.44) 19.88 (1.85) 4650 17.47 (1.62) 22.11 (2.05) 4656 19.44 (1.81) 24.34 (2.26) 4660 21.41 (1.99) 26.56 (2.47) 4666 23.38 (2.17) 28.79 (2.67) 4670 25.35 (2.35) 31.02 (2.88) 4676 27.32 (2.54) 33.25 (3.09) 4680 29.29 (2.72) 35.48 (3.30) 5010 1.94 (0.18) 4.75 (0.44) 5016 4.16 (0.39) 7.23 (0.67) 5020 6.38 (0.59) 9.71 (0.90) 5026 8.60 (0.80) 12.19 (1.13) 5030 10.82 (1.00) 14.67 (1.36) 5036 13.04 (1.21) 17.15 (1.59) 5040 15.25 (1.42) 19.63 (1.82) 5046 17.47 (1.62) 22.11 (2.05) 5050 19.69 (1.83) 24.59 (2.28) 5056 21.91 (2.04) 27.06 (2.51) 5060 24.13 (2.24) 29.54 (2.74) 5066 26.35 (2.45) 32.02 (2.97) 5070 28.57 (2.65) 34.50 (3.21) 5076 30.79 (2.86) 36.98 (3.44) 5080 33.00 (3.07) 39.46 (3.67) 5610 2.16 (0.20) 5.23 (0.49) 5616 4.63 (0.43) 7.96 (0.74) 5620 7.10 (0.66) 10.69 (0.99) 5626 9.57 (0.89) 13.42 (1.25) 5630 12.04 (1.12) 16.15 (1.50) 5636 14.50 (1.35) 18.88 (1.75) 5640 16.97 (1.58) 21.61 (2.01) 5646 19.44 (1.81) 24.34 (2.26) 5650 21.91 (2.04) 27.06 (2.51) 5656 24.38 (2.26) 29.79 (2.77) 5660 26.85 (2.49) 32.52 (3.02) 5666 29.32 (2.72) 35.25 (3.27) 5670 31.79 (2.95) 37.98 (3.53) 5676 34.25 (3.18) 40.71 (3.78) 5680 36.72 (3.41) 43.44 (4.04) Picture and Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 6010 2.38 (0.22) 5.71 (0.53) 6016 5.10 (0.47) 8.69 (0.81) 6020 7.82 (0.73) 11.67 (1.08) 6026 10.54 (0.98) 14.65 (1.36) 6030 13.25 (1.23) 17.63 (1.64) 6036 15.97 (1.48) 20.61 (1.91) 6040 18.69 (1.74) 23.59 (2.19) 6046 21.41 (1.99) 26.56 (2.47) 6050 24.13 (2.24) 29.54 (2.74) 6056 26.85 (2.49) 32.52 (3.02) 6060 29.57 (2.75) 35.50 (3.30) 6066 32.29 (3.00) 38.48 (3.57) 6070 35.00 (3.25) 41.46 (3.85) 6076 37.72 (3.50) 44.44 (4.13) 6080 40.44 (3.76) 47.42 (4.41) 6610 2.60 (0.24) 6.19 (0.57) 6616 5.57 (0.52) 9.42 (0.87) 6620 8.54 (0.79) 12.65 (1.17) 6626 11.50 (1.07) 15.88 (1.47) 6630 14.47 (1.34) 19.11 (1.77) 6636 17.44 (1.62) 22.34 (2.07) 6640 20.41 (1.90) 25.56 (2.37) 6646 23.38 (2.17) 28.79 (2.67) 6650 26.35 (2.45) 32.02 (2.97) 6656 29.32 (2.72) 35.25 (3.27) 6660 32.29 (3.00) 38.48 (3.57) 7010 2.82 (0.26) 6.67 (0.62) 7016 6.04 (0.56) 10.15 (0.94) 7020 9.25 (0.86) 13.63 (1.27) 7026 12.47 (1.16) 17.11 (1.59) 7030 15.69 (1.46) 20.59 (1.91) 7036 18.91 (1.76) 24.06 (2.24) 7040 22.13 (2.06) 27.54 (2.56) 7046 25.35 (2.35) 31.02 (2.88) 7050 28.57 (2.65) 34.50 (3.21) 7056 31.79 (2.95) 37.98 (3.53) 7060 35.00 (3.25) 41.46 (3.85) 7610 3.04 (0.28) 7.15 (0.66) 7616 6.50 (0.60) 10.88 (1.01) 7620 9.97 (0.93) 14.61 (1.36) 7626 13.44 (1.25) 18.34 (1.70) 7630 16.91 (1.57) 22.06 (2.05) 7636 20.38 (1.89) 25.79 (2.40) 7640 23.85 (2.22) 29.52 (2.74) 7646 27.32 (2.54) 33.25 (3.09) 7650 30.79 (2.86) 36.98 (3.44) 7656 34.25 (3.18) 40.71 (3.78) 7660 37.72 (3.50) 44.44 (4.13) 8010 3.25 (0.30) 7.63 (0.71) 8016 6.97 (0.65) 11.61 (1.08) 8020 10.69 (0.99) 15.59 (1.45) 8026 14.41 (1.34) 19.56 (1.82) 8030 18.13 (1.68) 23.54 (2.19) 8036 21.85 (2.03) 27.52 (2.56) 8040 25.57 (2.38) 31.50 (2.93) 8046 29.29 (2.72) 35.48 (3.30) 8050 33.00 (3.07) 39.46 (3.67) 8056 36.72 (3.41) 43.44 (4.04) 8060 40.44 (3.76) 47.42 (4.41) • Dimensions in parentheses are in square meters. (continued) 71 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES Triple Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1610-3 1.23 (0.11) 4.27 (0.40) 2010-3 1.89 (0.18) 5.71 (0.53) 2610-3 2.54 (0.24) 7.15 (0.66) 3010-3 3.20 (0.30) 8.59 (0.80) 3610-3 3.86 (0.36) 10.02 (0.93) 4010-3 4.51 (0.42) 11.46 (1.06) 1616-3 2.64 (0.24) 6.50 (0.60) 2016-3 4.04 (0.38) 8.69 (0.81) 2616-3 5.45 (0.51) 10.88 (1.01) 3016-3 6.86 (0.64) 13.06 (1.21) 3616-3 8.26 (0.77) 15.25 (1.42) 4016-3 9.67 (0.90) 17.44 (1.62) 1620-3 4.04 (0.38) 8.73 (0.81) 2020-3 6.20 (0.58) 11.67 (1.08) 2620-3 8.36 (0.78) 14.61 (1.36) 3020-3 10.51 (0.98) 17.54 (1.63) 3620-3 12.67 (1.18) 20.48 (1.90) 4020-3 14.82 (1.38) 23.42 (2.18) Twin Transom Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1610-2 0.82 (0.08) 2.84 (0.26) 1910-2 1.04 (0.10) 3.31 (0.31) 2010-2 1.26 (0.12) 3.79 (0.35) 2310-2 1.48 (0.14) 4.27 (0.40) 2610-2 1.70 (0.16) 4.75 (0.44) 2910-2 1.91 (0.18) 5.23 (0.49) 3010-2 2.13 (0.20) 5.71 (0.53) 3610-2 2.57 (0.24) 6.67 (0.62) 4010-2 3.01 (0.28) 7.63 (0.71) 1616-2 1.76 (0.16) 4.31 (0.40) 1916-2 2.23 (0.21) 5.04 (0.47) 2016-2 2.70 (0.25) 5.77 (0.54) 2316-2 3.16 (0.29) 6.50 (0.60) 2616-2 3.63 (0.34) 7.23 (0.67) 2916-2 4.10 (0.38) 7.96 (0.74) 3016-2 4.57 (0.42) 8.69 (0.81) 3616-2 5.51 (0.51) 10.15 (0.94) 4016-2 6.45 (0.60) 11.61 (1.08) 1620-2 2.70 (0.25) 5.79 (0.54) 1920-2 3.41 (0.32) 6.77 (0.63) 2020-2 4.13 (0.38) 7.75 (0.72) 2320-2 4.85 (0.45) 8.73 (0.81) 2620-2 5.57 (0.52) 9.71 (0.90) 2920-2 6.29 (0.58) 10.69 (0.99) 3020-2 7.01 (0.65) 11.67 (1.08) 3620-2 8.45 (0.78) 13.63 (1.27) 4020-2 9.88 (0.92) 15.59 (1.45) Half Circle Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 20 0.80 (0.07) 2.02 (0.19) 26 1.46 (0.14) 3.01 (0.28) 30 2.32 (0.22) 4.21 (0.39) 36 3.37 (0.31) 5.60 (0.52) 40 4.62 (0.43) 7.18 (0.67) 46 6.06 (0.56) 8.97 (0.83) 50 7.70 (0.72) 10.95 (1.02) 56 9.54 (0.89) 13.12 (1.22) 60 11.58 (1.08) 15.49 (1.44) 66 13.81 (1.28) 18.06 (1.68) 70 16.23 (1.51) 20.83 (1.93) 76 18.85 (1.75) 23.79 (2.21) 80 21.67 (2.01) 26.94 (2.50) 1610-2 1910-2 2010-2 2610-22310-2 2910-2 3010-2 3610-2 1610-3 2010-3 1616-2 1916-2 2016-2 2616-22316-2 2916-2 3016-2 3616-2 1616-3 2016-3 1620-2 1920-2 2020-2 2620-22320-2 2920-2 3020-2 3620-2 1620-3 2020-3 Window Dimension Unobstructed Glass (width of twin single sash) Unobstructed Glass (width of triple single sash) Minimum Rough Opening Table of Twin and Triple Transom Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 11 1/4" 2'-11 1/2" 3'-0" 11 1/4" 1' - 5 1/2" 1' - 6 " 17 1/4" 3'-11 1/2" 4'-0" 14 1/4" 3'-5 1/2" 3'-6" 17 1/4" 1' - 1 1 1/2" 2' - 0 " CU S T O M H E I G H T S — 11 1 ⁄ 2" t o 23 1 ⁄2" 5 1/4" 11 1/2" 1' - 0 " 4'-5 1/2" 4'-6" 20 1/4"23 1/4" 4'-11 1/2" 5'-0" 26 1/4" 5'-5 1/2" 5'-6"6'-0" 5'-11 1/2" 29 1/4"35 1/4" 6'-11 1/2" 7'-0" CUSTOM WIDTHS TWIN — 35 1 ⁄2" to 95 1 ⁄2" TRIPLE — 53 1 ⁄2" to 143 1 ⁄2" 17 1/4"11 1/4" (902) (914) (286) (44 5 ) (45 7 ) (28 6 ) (1207) (1219) (438) (1054) (1067) (362) (59 7 ) (61 0 ) (43 8 ) (29 2 ) (30 5 ) (13 3 ) (1359) (1372) (514) (1511) (1524) (591) (1664) (1676) (667) (1816) (1829) (743) (2121) (2134) (895) (286)(438) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Circle Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 2020 1.61 (0.15) 3.01 (0.28) 2626 2.93 (0.27) 4.75 (0.44) 3030 4.65 (0.43) 6.87 (0.64) 3636 6.75 (0.63) 9.39 (0.87) 4040 9.25 (0.86) 12.31 (1.14) • Dimensions in parentheses are in square meters. Notes on next page also apply to this page. • Dimensions in parentheses are in square meters. • Dimensions in parentheses are in square meters. • Dimensions in parentheses are in square meters. Click for revised "Half Circle Window Area Specifications" 72 PICTURE, TRANSOM & SPECIALTY WINDOWS Quarter Circle Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1616 0.69 (0.06) 1.82 (0.17) 2020 1.62 (0.15) 3.22 (0.30) 2626 2.95 (0.27) 5.01 (0.47) 3030 4.67 (0.43) 7.19 (0.67) 3636 6.78 (0.63) 9.77 (0.91) 4040 9.28 (0.86) 12.73 (1.18) 4646 12.18 (1.13) 16.09 (1.50) 5050 15.47 (1.44) 19.85 (1.84) Springline™ Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 2020 3.23 (0.30) 5.34 (0.50) 2026 3.95 (0.37) 6.32 (0.59) 2030 4.67 (0.43) 7.30 (0.68) 2036 5.38 (0.50) 8.28 (0.77) 2040 6.10 (0.57) 9.26 (0.86) 2046 6.81 (0.63) 10.24 (0.95) 2050 7.53 (0.70) 11.22 (1.04) 2620 4.74 (0.44) 7.19 (0.67) 2626 5.71 (0.53) 8.42 (0.78) 2630 6.67 (0.62) 9.65 (0.90) 2636 7.64 (0.71) 10.87 (1.01) 2640 8.61 (0.80) 12.10 (1.12) 2646 9.57 (0.89) 13.33 (1.24) Springline™ Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 2650 10.54 (0.98) 14.56 (1.35) 3020 6.45 (0.60) 9.23 (0.86) 3026 7.66 (0.71) 10.71 (0.99) 3030 8.88 (0.82) 12.19 (1.13) 3036 10.10 (0.94) 13.67 (1.27) 3040 11.31 (1.05) 15.15 (1.41) 3046 12.53 (1.16) 16.63 (1.54) 3050 13.74 (1.28) 18.11 (1.68) 3620 8.35 (0.78) 11.47 (1.07) 3626 9.81 (0.91) 13.20 (1.23) 3630 11.28 (1.05) 14.93 (1.39) 3636 12.75 (1.18) 16.66 (1.55) 3640 14.21 (1.32) 18.39 (1.71) 3646 15.68 (1.46) 20.12 (1.87) 3650 17.14 (1.59) 21.84 (2.03) 4020 10.45 (0.97) 13.90 (1.29) 4026 12.16 (1.13) 15.88 (1.48) 4030 13.88 (1.29) 17.86 (1.66) 4036 15.59 (1.45) 19.84 (1.84) 4040 17.31 (1.61) 21.82 (2.03) 4046 19.03 (1.77) 23.80 (2.21) 4050 20.74 (1.93) 25.78 (2.40) 4620 12.74 (1.18) 16.54 (1.54) 4626 14.71 (1.37) 18.77 (1.74) 4630 16.67 (1.55) 20.99 (1.95) 4636 18.64 (1.73) 23.22 (2.16) 4640 20.60 (1.91) 25.45 (2.36) 4646 22.57 (2.10) 27.68 (2.57) 4010-2 2610-3 3010-3 3610-3 4016-2 2616-3 4020-2 2620-3 3016-3 3616-3 3020-3 3620-3 4010-3 4016-3 4020-3 23 1/4" 7'-5 1/2" 7'-6" 41 1/4" 7'-11 1/2" 8'-0" 29 1/4" 8'-11 1/2" 9'-0" 35 1/4" 10'-5 1/2" 10'-6" 41 1/4" 11'-11 1/2" 12'-0" (2273) (2286) (591) (2426) (2438) (1048) (2731) (2743) (743) (3188) (3200) (895) (3645) (3658) (1048) Springline™ Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 4650 24.54 (2.28) 29.91 (2.78) 5020 15.23 (1.41) 19.36 (1.80) 5026 17.45 (1.62) 21.84 (2.03) 5030 19.66 (1.83) 24.32 (2.26) 5036 21.88 (2.03) 26.80 (2.49) 5040 24.09 (2.24) 29.28 (2.72) 5046 26.31 (2.44) 31.76 (2.95) 5050 28.53 (2.65) 34.24 (3.18) 5620 17.92 (1.66) 22.39 (2.08) 5626 20.38 (1.89) 25.12 (2.33) 5630 22.85 (2.12) 27.85 (2.59) 5636 25.31 (2.35) 30.58 (2.84) 5640 27.78 (2.58) 33.31 (3.09) 5646 30.25 (2.81) 36.03 (3.35) 5650 32.71 (3.04) 38.76 (3.60) 6020 20.80 (1.93) 25.61 (2.38) 6026 23.51 (2.18) 28.59 (2.66) 6030 26.23 (2.44) 31.57 (2.93) 6036 28.95 (2.69) 34.55 (3.21) 6040 31.66 (2.94) 37.53 (3.49) 6046 34.38 (3.19) 40.51 (3.76) 6050 37.10 (3.45) 43.48 (4.04) Custom-size windows are available in 1 ⁄8" (3) increments. See page 98 for custom sizes and specifications. Windows have one continuous outer frame. Details shown on pages 83-86. • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. • Dimensions in parentheses are in square meters. • Dimensions in parentheses are in square meters. Click for revised "Quarter Circle Window Area Specifications" 73 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES 20 26 30 36 40 50 56 60 66 70 76 80 46 Window Dimension Minimum Rough Opening Table of Half Circle Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 1'-11 1/2" 2'-0" 17 1/4" 2'-5 1/2" 2'-6" 23 1/4"29 1/4" 2'-11 1/2" 3'-0" 1' - 8 7/8" 1' - 9 3/8" 14 5/8" 1' - 6 3/8" 1' - 5 7/8" 11 5/8" 1' - 1 1 7/8" 2' - 0 3/8" 17 5/8" 2' - 2 7/8" 2' - 3 3/8" 20 5/8" 2' - 5 7/8" 2' - 6 3/8" 23 5/8" 2' - 8 7/8" 2' - 9 3/8" 26 5/8" 1' - 3 3/8" 1' - 2 7/8" 8 5/8" 3'-5 1/2" 3'-6" 35 1/4" 4'-5 1/2" 4'-6" 47 1/4" 53 1/4" 4'-11 1/2" 5'-0" 3'-11 1/2" 4'-0" 41 1/4" Unobstructed Glass 59 1/4" 5'-5 1/2" 5'-6"6'-0" 5'-11 1/2" 65 1/4"71 1/4" 6'-5 1/2" 6'-6" 77 1/4" 6'-11 1/2" 7'-0" 83 1/4" 7'-5 1/2" 7'-6" 89 1/4" 7'-11 1/2" 8'-0" 2' - 1 1 7/8" 3' - 0 3/8" 29 5/8" 3' - 8 7/8" 3' - 9 3/8" 38 5/8" 3' - 2 7/8" 3' - 3 3/8" 32 5/8" 3' - 5 7/8" 3' - 6 3/8" 35 5/8" 11 3/4"Radius 14 3/4"17 3/4" 20 3/4"23 3/4"26 3/4" 29 3/4" 32 3/4"35 3/4"38 3/4" 41 3/4"44 3/4" 3' - 1 1 7/8" 4' - 0 3/8" 41 5/8" 47 3/4" 4' - 2 7/8" 4' - 3 3/8" 44 5/8" (749) (762) (591) (597) (610) (438) (902) (914) (743) (68 3 ) (69 5 ) (52 4 ) (75 9 ) (60 0 ) (83 5 ) (84 8 ) (67 6 ) (77 2 ) (4 5 4 ) (46 7 ) (29 5 ) (53 0 ) (54 3 ) (37 1 ) (60 6 ) (61 9 ) (44 8 ) (3 7 8 ) (39 1 ) (21 9 ) (1353) (1200)(1048)(895) (1524) (1372)(1219)(1067) (1511) (1359)(1207)(1054) (1664) (1676) (1505) (1816) (1829) (1657) (1969) (1981) (1810) (2121) (2134) (1962) (2273) (2286) (2115) (2426) (2438) (2267) (91 1 ) (92 4 ) (75 2 ) (11 4 0 ) (11 5 3 ) (98 1 ) (98 7 ) (10 0 0 ) (82 9 ) (10 6 4 ) (10 7 6 ) (90 5 ) (298)(375)(451) (527)(603)(679) (756)(832)(908)(984) (1060)(1137) (12 1 6 ) (12 2 9 ) (10 5 7 ) (1213) (12 9 2 ) (13 0 5 ) (11 3 3 ) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Custom-size half circle windows are available in 1 ⁄8" (3) increments. Contact your Andersen supplier for more information. Grille patterns shown on page 79. Details shown on pages 83-86. Click for revised "Table of Half Circle Window Sizes" 74 PICTURE, TRANSOM & SPECIALTY WINDOWS 2020 2626 3030 3636 4040 Window Dimension Unobstructed Glass Minimum Rough Opening Table of Circle Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 1'-11 1/2" 2'-0" 17 1/4" 2'-5 1/2" 2'-6" 23 1/4"29 1/4" 2'-11 1/2" 3'-0" 3'-5 1/2" 3'-6" 35 1/4" 3'-11 1/2" 4'-0" 41 1/4" (749) (762) (591) (597) (610) (438) (902) (914) (743)(1048)(895) (1219)(1067) (1207)(1054) 1616 2020 2626 3030 3636 4040 4646 5050 Window Dimension Minimum Rough Opening Table of Quarter Circle Window Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 1'-11 1/2" 2'-0" 17 1/2" 2'-5 1/2" 2'-6" 23 1/4" 1'-5 1/2" 1'-6" 5 1/4"29 1/4" 2'-11 1/2" 3'-0" 2' - 1 1 1/2" 3' - 0 " 29 1/4" 2' - 6 " 2' - 5 1/2" 23 1/4" 3' - 5 1/2" 3' - 6 " 35 1/4" 3' - 1 1 1/2" 4' - 0 " 41 1/4" 4' - 5 1/2" 4' - 6 " 47 1/4" 4' - 1 1 1/2" 5' - 0 " 53 1/4" 1' - 6 " 1' - 5 1/2" 5 1/4" 2' - 0 " 1' - 1 1 1/2" 17 1/2" 3'-5 1/2" 3'-6" 35 1/4" 4'-5 1/2" 4'-6" 47 1/4"53 1/4" 4'-11 1/2" 5'-0" 3'-11 1/2" 4'-0" 41 1/4" Unobstructed Glass 32 3/8"26 3/8"20 3/8"14 3/8" 56 3/8"50 3/8"44 3/8"38 3/8" Radius (749) (762) (591) (597) (610) (438) (445) (457) (133) (902) (914) (743) (12 0 7 ) (12 1 9 ) (10 4 8 ) (13 5 9 ) (12 0 0 ) (15 1 1 ) (15 2 4 ) (13 5 3 ) (13 7 2 ) (7 4 9 ) (76 2 ) (59 1 ) (90 2 ) (91 4 ) (74 3 ) (10 5 4 ) (10 6 7 ) (89 5 ) (4 4 5 ) (45 7 ) (13 3 ) (5 9 7 ) (61 0 ) (43 8 ) (1353)(1200)(1048)(895) (1524)(1372)(1219)(1067) (1511)(1359)(1207)(1054) (822)(670)(518)(365) (1432)(1280)(1127)(975) • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Custom-size circle windows are available in 1 ⁄8" (3) increments. Contact your Andersen supplier for more information. Grille patterns shown on page 79. Details shown on pages 83-86. Custom-size quarter circle windows are available in 1 ⁄8" (3) increments. Contact your Andersen supplier for more information. Grille patterns shown on page 79. Details shown on pages 83-86. Click for revised "Table of Quarter Circle Window Sizes" 75 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES Window Height Side Height Window Width Window Width Custom Peak Pentagon Custom-size design limitations: Min./Max. Window Width 17 1 ⁄2" (445) to 107 1 ⁄2" (2731) Min./Max. Window Height 14 1 ⁄8" (359) to 107 1 ⁄2" (2731) Min./Max. Side Height 9 3 ⁄4" (248) to 94 1 ⁄8" (2391) Max. Frame Area: 40 sq. ft. or 3.7 m2 Based on the smallest square or rectangular shape that covers the entire window. Additional limitations may apply. Contact your Andersen supplier for more information. Contains sides of equal length, extending at right angles from the sill and two angled sides of equal length that peak above the center of the sill. These custom shapes are available in 1 ⁄8" (3) increments. Design Criteria Listed for each custom shape are factors that must be considered when deciding on a custom-shaped specialty window. Grilles are available for most shapes and sizes in colonial and specified equal divided light patterns. For more grille options, see page 14 or contact your Andersen supplier. Details shown on pages 83-86. Window Height Short Side Height Window Width Window Width Custom Trapezoid Custom-size design limitations: Min./Max. Window Width 17 1 ⁄2" (445) to 107 1 ⁄2" (2731) Min./Max. Window Height 9 7 ⁄8" (251) to 95 1 ⁄2" (2426) Min./Max. Short Side Height 9 3 ⁄4" (248) to 95 3 ⁄8" (2423) Max. Frame Area: 40 sq. ft. or 3.7 m2 Based on the smallest square or rectangular shape that covers the entire window. Additional limitations may apply. Contact your Andersen supplier for more information. Choose left facing (1) or right facing (2) as viewed from the exterior. Contains a slope to the left or right. Slope is often designed to match a roof’s pitch. 1 Window Height Short Side Height Window Height Short Side Height Window Width Window Width 2 Custom Unequal Leg Arch Custom-size design limitations: Min./Max. Window Width 17 1 ⁄2" (445) to 95 1 ⁄2" (2426) Min./Max. Window Height 11 3 ⁄8" (289) to 95 1 ⁄2" (2426) Min./Max. Short Side Height 9 3 ⁄4" (248) to 93 7 ⁄8" (2384) Max. Frame Area: 40 sq. ft. or 3.7 m2 Based on the smallest square or rectangular shape that covers the entire window. Additional limitations may apply. Contact your Andersen supplier for more information. Choose left facing (1) or right facing (2) as viewed from the exterior. Contains unequal legs, two right angles at the sill and an arch at the top. 1 2 • Dimensions in parentheses are in millimeters. 76 PICTURE, TRANSOM & SPECIALTY WINDOWS 2 1 Choose left facing (1) or right facing (2) as viewed from the exterior. Contains one 90-degree angle. Window Height Window Width Window Width Window Height Custom Right Triangle Custom-size design limitations: Min./Max. Window Width 17 1 ⁄2" (445) to 95 1 ⁄2" (2426) Min./Max. Window Height 17 1 ⁄2" (445) to 95 1 ⁄2" (2426) Max. Frame Area: 40 sq. ft. or 3.7 m2 Based on the smallest square or rectangular shape that covers the entire window. Additional limitations may apply. Contact your Andersen supplier for more information. Window Height Window Width Contains two sides of equal length and two equal angles. Custom Isosceles Triangle Custom-size design limitations: Min./Max. Window Width 17 1 ⁄2" (445) to 107 1 ⁄2" (2731) Min./Max. Window Height 17 1 ⁄2" (445) to 75 7 ⁄8" (1927) Max. Frame Area: 40 sq. ft. or 3.7 m2 Based on the smallest square or rectangular shape that covers the entire window. Additional limitations may apply. Contact your Andersen supplier for more information. Contains eight equal angles and sides. Equal Sides Window Height Window Width Custom Octagon Custom-size design limitations: Min./Max. Window Width 23 1 ⁄2" (597) to 71 1 ⁄2" (1816) Min./Max. Window Height 23 1 ⁄2" (597) to 71 1 ⁄2" (1816) Additional limitations may apply. Contact your Andersen supplier for more information. Window Width Window Height Short Side Height Top Width Window Width Custom Angled Pentagon Custom-size design limitations: Min./Max. Window Width 17 1 ⁄2" (445) to 107 1 ⁄2" (2731) Min./Max. Top Width 9 3 ⁄4" (248) to 107 3 ⁄8" (2727) Min./Max. Window Height 14 3 ⁄8" (365) to 107 1 ⁄2" (2731) Min./Max. Short Side Height 9 3 ⁄4" (248) to 94 1 ⁄8" (226) Max. Frame Area: 40 sq. ft. or 3.7 m2 Based on the smallest square or rectangular shape that covers the entire window. Additional limitations may apply. Contact your Andersen supplier for more information. 1 Choose left facing (1) or right facing (2) as viewed from the exterior. Contains an angle cut, or a “clipped corner,” sloping to the left or right. 2 • Dimensions in parentheses are in millimeters. 77 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. 3020 36202020 2620 502040204620 3026 36262026 2626 502640264626 3030 36302030 2630 503040304630 3036 36362036 2636 503640364636 3040 36402040 2640 504040404640 3046 36462046 2646 504640464646 3050 36502050 2650 505040504650 CUSTOM SIZES AVAILABLE CU S T O M S I Z E S A V A I L A B L E Table of Springline™ Window Sizes Window Width Dimension Minimum Rough Opening 11 3/4" 14 3/4" 17 3/4"20 3/4" Si d e H e i g h t Radius Chord Height Mi n i m u m R o u g h O p e n i n g = W i n d o w H e i g h t + 1 ⁄ 2" 11 3/4" 14 3/4" 17 3/4" 20 3/4" Unobstructed Glass 1'-11 1/2" 2'-0" 17 1/4" 2'-5 1/2" 3'-6" 3'-5 1/2" 2'-6" 23 1/4"35 1/4"29 1/4" 2'-11 1/2" 3'-0" 4' - 2 1/4" 4' - 8 1/4" 5' - 2 1/4" 5' - 8 1/4" 6' - 2 1/4" 6' - 8 1/4" (3 7 5 ) 3 ' - 1 1 1/4" (4 5 1 ) 3' - 8 1/4" 4' - 5 1/4" 4' - 2 1/4" 4 ' - 1 1 1/4" 4' - 8 1/4" 5' - 5 1/4" 5' - 2 1/4" 5 ' - 1 1 1/4" 5' - 8 1/4" 6' - 5 1/4" 6' - 2 1/4" 2' - 5 1/2" 2 ' - 1 1 1/2" 3' - 5 1/2" 3' - 5 1/4" 3' - 1 1 1/4" 4' - 5 1/4" 3 ' - 1 1 1/2" 4' - 1 1 1/4" 4' - 5 1/2" 5' - 5 1/4" 4' - 1 1 1/2" 5 ' - 1 1 1/4" Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 Window Height Shown in Table Un o b s t r u c t e d G l a s s = W i n d o w H e i g h t – 6 . 2 5 " (1 5 9 ) 23 3/4" 23 3/4" 4'-0" 3'-11 1/2" 41 1/4" 26 3/4" 26 3/4" 4'-6" 4'-5 1/2" 47 1/4" 29 3/4" 29 3/4" 5'-0" 4'-11 1/2" 53 1/4" 1' - 1 1 1/2" 2 ' - 1 1 1/4" 3' - 2 1/4" 3' - 5 1/4" 3' - 8 1/4" 3' - 1 1 1/4" 4' - 2 1/4" 4' - 5 1/4" 4' - 5 1/4" 4' - 8 1/4" 4 ' - 1 1 1/4" 4' - 1 1 1/4" 5' - 2 1/4" 5' - 5 1/4" 5' - 5 1/4" 5' - 8 1/4" 5' - 1 1 1/4" 5' - 1 1 1/4" 6' - 2 1/4" 6' - 5 1/4" 6' - 5 1/4" 6' - 8 1/4" 6 ' - 1 1 1/4" 6 ' - 1 1 1/4" 7' - 2 1/4" 7' - 5 1/4" (451) (527)(298)(375) (1 3 ) (2 9 8 ) (5 2 7 ) (1 0 4 8 ) (1 2 0 0 ) (1 2 7 6 ) (1 5 8 1 ) (1 3 5 3 ) (7 4 9 ) (9 0 2 ) (1 2 0 0 ) (1 3 5 3 ) (1 5 0 5 ) (1 0 5 4 ) (1 1 2 4 ) (1 2 7 6 ) (1 4 2 9 ) (1 7 3 4 ) (1 5 0 5 ) (1 6 5 7 ) (1 2 0 7 ) (1 5 8 1 ) (1 8 8 6 ) (1 6 5 7 ) (1 8 1 0 ) (1 3 5 9 ) (1 7 3 4 ) (2 0 3 8 ) (1 8 1 0 ) (1 9 6 2 ) (1 5 1 1 ) (1 8 8 6 ) (749) (762) (591) (597) (610) (438) (1054) (1067) (895) (902) (914) (743) (603) (6 0 3 ) (1207) (1219) (1048) (679) (6 7 9 ) (1359) (1372) (1200) (756) (7 5 6 ) (1511) (1524) (1353) (1 4 2 9 ) (8 9 5 ) (5 9 7 ) (9 7 2 ) (1 0 4 8 ) (1 1 2 4 ) (1 2 0 0 ) (1 2 7 6 ) (1 3 5 3 ) (1 3 5 3 ) (1 4 2 9 ) (1 5 0 5 ) (1 5 0 5 ) (1 5 8 1 ) (1 6 5 7 ) (1 6 5 7 ) (1 7 3 4 ) (1 8 1 0 ) (1 8 1 0 ) (1 8 8 6 ) (1 9 6 2 ) (1 9 6 2 ) (2 0 3 8 ) (2 1 1 5 ) (2 1 1 5 ) (2 1 9 1 ) (2 2 6 7 ) Notes on next page also apply to this page. 78 PICTURE, TRANSOM & SPECIALTY WINDOWS 79 • Window Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. 5620 6020 5626 6026 5630 6030 5636 6036 5640 6040 5646 6046 5650 6050 32 3/4" 32 3 ⁄4" 5'-6" 5'-5 1/2" 59 1/4" 34 3/4" 34 3 ⁄4" 5'-11 1/2" 6'-0" 65 1/4" 4' - 1 1 1/4" 4' - 8 1/4" 5' - 5 1/4" 5' - 2 1/4" 5' - 1 1 1/4" 5' - 8 1/4" 6' - 5 1/4" 6' - 2 1/4" 6 ' - 1 1 1/4" 6' - 8 1/4" 7' - 5 1/4" 7' - 2 1/4" 7 ' - 1 1 1/4" 7' - 8 1/4" (832) (8 3 2 ) (1664) (1676) (1505) (908) (1816) (1829) (1657) (9 0 8 ) (1 5 0 5 ) (1 4 2 9 ) (1 6 5 7 ) (1 5 8 1 ) (1 8 1 0 ) (1 7 3 4 ) (1 9 6 2 ) (1 8 8 6 ) (2 1 1 5 ) (2 0 3 8 ) (2 2 6 7 ) (2 1 9 1 ) (2 4 1 9 ) (2 3 4 3 ) Half Circle Quarter Circle Circle Springline™ Arch Grille Patterns Colonial Renaissance Sunburst Prairie A Colonial Colonial Fractional Fractional Modied Tall Short Transom Picture Custom Pattern ExamplesSpecied Equal Light Examples Number of lights and overall pattern varies with window size. Patterns may not be available in all configurations or sizes. Specialty window patterns may not align with picture window patterns when joined. Specified equal light pattern is available for all shapes except quarter circle. For specified equal light, specify number of same-size rectangles across or down. Custom grille patterns are available for picture and transom windows. For more grille options, see page 14 or visit andersenwindows.com/grilles. Custom-size windows are available in 1 ⁄8" (3) increments. Contact your Andersen supplier for more information. For Springline™ and arch windows, the size designation does not reflect the overall window height (e.g., a 2020 Springline window size has a side height of 1'-11 1 ⁄2" and an overall window height of 2'-11 1 ⁄4"). Grille patterns shown below. Details shown on pages 83-86. 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES 3010 36102010 501040104610 3016 36162016 2616 501640164616 3020 36202020 2620 502040204620 3026 36262026 2626 502640264626 3030 36302030 2630 503040304630 3036 36362036 2636 503640364636 3040 36402040 2640 504040404640 3046 36462046 2646 504640464646 3050 36502050 2650 505040504650 3656 505640564656 3660 506040604660 30562056 2656 30602060 2660 2610 CUSTOM SIZES AVAILABLE CU S T O M S I Z E S A V A I L A B L E Table of Arch Window Sizes Window Width Dimension Minimum Rough Opening 23 1/2"29 1/2"35 1/2"41 1/2" Si d e H e i g h t Radius Chord Height Mi n i m u m R o u g h O p e n i n g = W i n d o w H e i g h t + 1 ⁄ 2" 3 5 ⁄ 32 " 3 15 ⁄16 " 4 3 ⁄4" 5 9 ⁄16 " Unobstructed Glass 1'-11 1/2" 2'-0" 17 1/4" 2'-5 1/2" 3'-6" 3'-5 1/2" 2'-6" 23 1/4"35 1/4"29 1/4" 2'-11 1/2" 3'-0" 2 ' - 1 1 1/16 " 3' - 5 1/16 " 3' - 1 1 1/16 " 4' - 5 1/16 " 4' - 1 1 1/16 " 5' - 5 1/16 " 5' - 1 1 1/16 " 6' - 5 1/16 " (1 0 0 ) 2 ' - 1 0 1/4" (1 2 1 ) 2' - 9 7/16 " 3' - 4 1/4" 3' - 3 7/16 " 3 ' - 1 0 1/4" 3' - 9 7/16 " 4' - 4 1/4" 4' - 3 7/16 " 4' - 1 0 1/4" 4' - 9 7/16 " 5' - 4 1/4" 5' - 3 7/16 " 5' - 1 0 1/4" 5' - 9 7/16 " 6' - 4 1/4" 6' - 3 7/16 " 2' - 5 1 ⁄ 2" 2 ' - 1 1 1 ⁄ 2" 3' - 5 1 ⁄ 2" 2' - 8 21 /32 " 3' - 2 21 /32 " 3' - 8 21 /32 " 3' - 1 1 1 ⁄ 2" 4' - 2 21 /32 " 4' - 5 1 ⁄ 2" 4' - 8 21 /32 " 4' - 1 1 1 ⁄ 2" 5' - 2 21 /32 " 5' - 5 1 ⁄ 2" 5' - 8 21 /32 " 5' - 1 1 1 ⁄ 2" 6' - 2 21 /32 " Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 Window Height Shown in Table Un o b s t r u c t e d G l a s s = W i n d o w H e i g h t – 6 . 2 5 " (1 5 9 ) 11 1 ⁄ 2" 1' - 2 21 /32 " 1' - 3 7/16 " 47 1/2" 6 3 ⁄ 8" 4'-0" 3'-11 1/2" 41 1/4" 53 1/2" 7 5 ⁄32 " 4'-6" 4'-5 1/2" 47 1/4" 59 1/2" 7 31 ⁄ 32 " 5'-0" 4'-11 1/2" 53 1/4" 1' - 4 1/4" 1' - 5 1/16 " 1' - 5 7/8" 1' - 6 21 /32 " 1' - 7 15 /32 " 1' - 5 1 ⁄ 2" 1' - 8 21 /32 " 1' - 9 7/16 " 1' - 1 0 1/4" 1' - 1 1 1/16 " 1' - 1 1 7/8" 2' - 0 21 /32 " 2 ' - 1 15 /32 " 1' - 1 1 1 ⁄ 2" 2' - 2 21 /32 " 2' - 3 7/16 " 2' - 4 1/4" 2' - 5 1/16 " 2' - 5 7/8" 2' - 6 21 /32 " 2' - 7 15 /32 " 2' - 1 1 7/8" 3' - 0 21 /32 " 3 ' - 1 15 /32 " 3' - 5 7/8" 3' - 6 21 /32 " 3' - 7 15 /32 " 3' - 1 1 7/8" 4' - 0 21 /32 " 4' - 1 15 /32 " 4' - 5 7/8" 4' - 6 21 /32 " 4' - 7 15 /32 " 4' - 1 1 7/8" 5' - 0 21 /32 " 5 ' - 1 15 /32 " 5' - 5 7/8" 5' - 6 21 /32 " 5' - 7 15 /32 " 5' - 1 1 7/8" 6' - 0 21 /32 " 6 ' - 1 15 /32 " 6' - 5 7/8" 6' - 6 21 /32 " 6' - 7 15 /32 " (902)(1054)(597)(749) (1 3 ) (8 0 ) (1 4 1 ) (8 2 9 ) (9 8 2 ) (8 9 1 ) (1 1 9 5 ) (1 1 3 4 ) (7 4 9 ) (9 0 2 ) (8 7 0 ) (1 0 2 3 ) (1 1 7 5 ) (1 0 5 4 ) (8 5 0 ) (1 0 0 2 ) (1 1 5 4 ) (1 3 4 8 ) (1 2 8 6 ) (1 3 2 7 ) (1 2 0 7 ) (1 3 0 7 ) (1 5 0 0 ) (1 4 3 9 ) (1 4 8 0 ) (1 3 5 9 ) (1 4 5 9 ) (1 6 5 3 ) (1 5 9 1 ) (1 6 3 2 ) (1 5 1 1 ) (1 6 1 2 ) (1 8 0 5 ) (1 7 4 4 ) (1 7 8 5 ) (1 6 6 4 ) (1 7 6 4 ) (1 9 5 7 ) (1 8 9 6 ) (1 9 3 7 ) (1 8 1 6 ) (1 9 1 6 ) (749) (762) (591) (597) (610) (438) (1054) (1067) (895) (902) (914) (743) (3 7 2 ) (2 9 2 ) (3 9 2 ) (1207) (1 6 2 ) (1207) (1219) (1048) (1359) (1 8 2 ) (1359) (1372) (1200) (1511) (2 0 2 ) (1511) (1524) (1353) (4 1 3 ) (4 3 3 ) (4 5 4 ) (4 7 4 ) (4 9 5 ) (1 0 4 3 ) (5 2 4 ) (4 4 5 ) (5 4 5 ) (5 6 5 ) (5 8 6 ) (6 0 6 ) (6 2 7 ) (6 4 7 ) (6 7 7 ) (5 9 7 ) (6 9 7 ) (7 1 8 ) (7 3 8 ) (7 5 9 ) (7 7 9 ) (7 9 9 ) (9 1 1 ) (9 3 1 ) (9 5 2 ) (1 0 6 3 ) (1 0 8 4 ) (1 1 0 4 ) (1 2 1 6 ) (1 2 3 6 ) (1 2 5 7 ) (1 3 6 8 ) (1 3 8 9 ) (1 4 0 9 ) (1 5 2 1 ) (1 5 4 1 ) (1 5 6 1 ) (1 6 7 3 ) (1 6 9 3 ) (1 7 1 4 ) (1 8 2 5 ) (1 8 4 6 ) (1 8 6 6 ) (1 9 7 8 ) (1 9 9 8 ) (2 0 1 9 ) Notes on page 79 also apply to this page. 80 PICTURE, TRANSOM & SPECIALTY WINDOWS Notes on page 79 also apply to this page. 5610 6010 7610 801066107010 5616 6016 7616 801666167016 5620 6020 7620 802066207020 5626 6026 7626 802666267026 5630 6030 7630 803066307030 5636 6036 7636 803666367036 5640 6040 7640 804066407040 5646 6046 7646 804666467046 5650 6050 7650 805066507050 5656 6056 7656 805666567056 5660 6060 7660 806066607060 65 1/2" 8 25 ⁄ 32 " 5'-6" 5'-5 1/2" 59 1/4" 71 1/2" 9 19 ⁄ 32 " 5'-11 1/2" 6'-0" 65 1/4" 1' - 9 3/32 " 77 1/2" 10 3 ⁄ 8" 6'-5 1/2" 6'-6" 71 1/4" 1' - 9 7/8" 83 1/2" 11 3 ⁄16 " 6'-11 1/2" 7'-0" 77 1/4" 1' - 1 0 11 /16 " 89 1/2" 12 " 7'-5 1/2" 7'-6" 83 1/4" 1' - 1 1 1/2" 95 1/2" 12 25 /32 " 7'-11 1/2" 8'-0" 89 1/4" 2' - 0 9/32 " 1' - 8 9/32 " 2' - 3 3/32 " 2' - 3 7/8" 2' - 4 11 /16 " 2' - 5 1/2" 2' - 6 9/32 " 2' - 2 9/32 " 2' - 9 3/32 " 2' - 9 7/8" 2 ' - 1 0 11 /16 " 2 ' - 1 1 1/2" 3' - 0 9/32 " 2' - 8 9/32 " 3' - 3 3/32 " 3' - 3 7/8" 3' - 4 11 /16 " 3' - 5 1/2" 3' - 6 9/32 " 3' - 2 9/32 " 3' - 9 3/32 " 3' - 9 7/8" 3' - 1 0 11 /16 " 3 ' - 1 1 1/2" 4' - 0 9/32 " 3' - 8 9/32 " 4' - 3 3/32 " 4' - 3 7/8" 4' - 4 11 /16 " 4' - 5 1/2" 4' - 6 9/32 " 4' - 2 9/32 " 4' - 9 3/32 " 4' - 9 7/8" 4' - 1 0 11 /16 " 4 ' - 1 1 1/2" 5' - 0 9/32 " 4' - 8 9/32 " 5' - 3 3/32 " 5' - 3 7/8" 5' - 4 11 /16 " 5' - 5 1/2" 5' - 6 9/32 " 5' - 2 9/32 " 5' - 9 3/32 " 5' - 9 7/8" 5 ' - 1 0 11 /16 " 5' - 1 1 1/2" 6' - 0 9/32 " 5' - 8 9/32 " 6' - 3 3/32 " 6' - 3 7/8" 6' - 4 11 /16 " 6' - 5 1/2" 6' - 6 9/32 " 6' - 2 9/32 " 6' - 9 3/32 " 6' - 9 7/8" 6 ' - 1 0 11 /16 " 6 ' - 1 1 1/2" 7' - 0 9/32 " 6' - 8 9/32 " (1664) (2 2 3 ) (1664) (1676) (1505) (1816) (1816) (1829) (1657) (5 3 5 ) (1969) (2 6 4 ) (1969) (1981) (1810) (5 5 6 ) (2121) (2 8 4 ) (2121) (2134) (1962) (5 7 6 ) (2273) (3 0 5 ) (2273) (2286) (2115) (5 9 7 ) (2426) (3 2 5 ) (2426) (2438) (2267) (6 1 7 ) (5 1 5 ) (2 4 3 ) (6 8 8 ) (7 0 8 ) (7 2 9 ) (7 4 9 ) (7 6 9 ) (6 6 7 ) (8 4 0 ) (8 6 1 ) (8 8 1 ) (9 0 1 ) (9 2 2 ) (8 2 0 ) (9 9 3 ) (1 0 1 3 ) (1 0 3 3 ) (1 0 5 4 ) (1 0 7 4 ) (9 7 2 ) (1 1 4 5 ) (1 1 6 5 ) (1 1 8 6 ) (1 2 0 6 ) (1 2 2 7 ) (1 1 2 5 ) (1 2 9 7 ) (1 3 1 8 ) (1 3 3 8 ) (1 3 5 9 ) (1 3 7 9 ) (1 2 7 7 ) (1 4 5 0 ) (1 4 7 0 ) (1 4 9 1 ) (1 5 1 1 ) (1 5 3 1 ) (1 4 2 9 ) (1 6 0 2 ) (1 6 2 3 ) (1 6 4 3 ) (1 6 6 3 ) (1 6 8 4 ) (1 5 8 2 ) (1 7 5 5 ) (1 7 7 5 ) (1 7 9 5 ) (1 8 1 6 ) (1 8 3 6 ) (1 7 3 4 ) (1 9 0 7 ) (1 9 2 7 ) (1 9 4 8 ) (1 9 6 8 ) (1 9 8 9 ) (1 8 8 7 ) (2 0 5 9 ) (2 0 8 0 ) (2 1 0 0 ) (2 1 2 1 ) (2 1 4 1 ) (2 0 3 9 ) 81 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES Arch Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 4640 15.26 (1.42) 19.45 (1.81) 4646 17.23 (1.60) 21.68 (2.01) 4650 19.20 (1.78) 23.91 (2.22) 4656 21.17 (1.97) 26.14 (2.43) 4660 23.13 (2.15) 28.36 (2.64) 5010 4.09 (0.38) 6.98 (0.65) 5016 6.30 (0.59) 9.46 (0.88) 5020 8.52 (0.79) 11.94 (1.11) 5026 10.74 (1.00) 14.42 (1.34) 5030 12.96 (1.20) 16.90 (1.57) 5036 15.18 (1.41) 19.37 (1.80) 5040 17.40 (1.62) 21.85 (2.03) 5046 19.62 (1.82) 24.33 (2.26) 5050 21.84 (2.03) 26.81 (2.49) 5056 24.05 (2.23) 29.29 (2.72) 5060 26.27 (2.44) 31.77 (2.95) 5610 4.77 (0.44) 7.93 (0.74) 5616 7.24 (0.67) 10.66 (0.99) 5620 9.71 (0.90) 13.39 (1.24) 5626 12.18 (1.13) 16.12 (1.50) 5630 14.65 (1.36) 18.85 (1.75) 5636 17.11 (1.59) 21.58 (2.00) 5640 19.58 (1.82) 24.30 (2.26) 5646 22.05 (2.05) 27.03 (2.51) 5650 24.52 (2.28) 29.76 (2.77) 5656 26.99 (2.51) 32.49 (3.02) 5660 29.46 (2.74) 35.22 (3.27) 6010 5.50 (0.51) 8.93 (0.83) 6016 8.22 (0.76) 11.91 (1.11) 6020 10.94 (1.02) 14.88 (1.38) 6026 13.66 (1.27) 17.86 (1.66) 6030 16.38 (1.52) 20.84 (1.94) 6036 19.09 (1.77) 23.82 (2.21) 6040 21.81 (2.03) 26.80 (2.49) 6046 24.53 (2.28) 29.78 (2.77) 6050 27.25 (2.53) 32.76 (3.04) 6056 29.97 (2.78) 35.74 (3.32) 6060 32.69 (3.04) 38.72 (3.60) 6610 6.27 (0.58) 9.97 (0.93) 6616 9.24 (0.86) 13.20 (1.23) 6620 12.21 (1.13) 16.43 (1.53) 6626 15.18 (1.41) 19.66 (1.83) 6630 18.15 (1.69) 22.88 (2.13) 6636 21.12 (1.96) 26.11 (2.43) 6640 24.09 (2.24) 29.34 (2.73) 6646 27.06 (2.51) 32.57 (3.03) 6650 30.02 (2.79) 35.80 (3.33) 6656 32.99 (3.07) 39.03 (3.63) 6660 35.96 (3.34) 42.26 (3.93) 7010 7.10 (0.66) 11.05 (1.03) 7016 10.31 (0.96) 14.53 (1.35) 7020 13.53 (1.26) 18.01 (1.67) 7026 16.75 (1.56) 21.49 (2.00) 7030 19.97 (1.86) 24.97 (2.32) 7036 23.19 (2.15) 28.45 (2.64) 7040 26.41 (2.45) 31.93 (2.97) 7046 29.63 (2.75) 35.41 (3.29) 7050 32.85 (3.05) 38.89 (3.61) 7056 36.06 (3.35) 42.37 (3.94) 7060 39.28 (3.65) 45.85 (4.26) 7610 7.96 (0.74) 12.19 (1.13) Arch Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 7616 11.43 (1.06) 15.92 (1.48) 7620 14.90 (1.38) 19.64 (1.83) 7626 18.37 (1.71) 23.37 (2.17) 7630 21.84 (2.03) 27.10 (2.52) 7636 25.30 (2.35) 30.83 (2.86) 7640 28.77 (2.67) 34.56 (3.21) 7646 32.24 (3.00) 38.29 (3.56) 7650 35.71 (3.32) 42.02 (3.90) 7656 39.18 (3.64) 45.75 (4.25) 7660 42.65 (3.96) 49.48 (4.60) 8010 8.87 (0.82) 13.36 (1.24) 8016 12.59 (1.17) 17.34 (1.61) 8020 16.31 (1.52) 21.32 (1.98) 8026 20.03 (1.86) 25.30 (2.35) 8030 23.75 (2.21) 29.28 (2.72) 8036 27.47 (2.55) 33.26 (3.09) 8040 31.18 (2.90) 37.24 (3.46) 8046 34.90 (3.24) 41.22 (3.83) 8050 38.62 (3.59) 45.20 (4.20) 8056 42.34 (3.93) 49.18 (4.57) 8060 46.06 (4.28) 53.16 (4.94) Arch Window Area Specifications Window Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 2010 0.93 (0.09) 2.22 (0.21) 2016 1.65 (0.15) 3.20 (0.30) 2020 2.37 (0.22) 4.18 (0.39) 2026 3.09 (0.29) 5.16 (0.48) 2030 3.81 (0.35) 6.14 (0.57) 2036 4.52 (0.42) 7.12 (0.66) 2040 5.24 (0.49) 8.10 (0.75) 2046 5.96 (0.55) 9.08 (0.84) 2050 6.68 (0.62) 10.06 (0.93) 2056 7.40 (0.69) 11.04 (1.03) 2060 8.12 (0.75) 12.02 (1.12) 2610 1.34 (0.12) 2.90 (0.27) 2616 2.31 (0.21) 4.13 (0.38) 2620 3.28 (0.30) 5.36 (0.50) 2626 4.25 (0.39) 6.59 (0.61) 2630 5.22 (0.48) 7.82 (0.73) 2636 6.19 (0.57) 9.05 (0.84) 2640 7.16 (0.66) 10.28 (0.95) 2646 8.12 (0.75) 11.51 (1.07) 2650 9.09 (0.84) 12.74 (1.18) 2656 10.06 (0.93) 13.97 (1.30) 2660 11.03 (1.02) 15.20 (1.41) 3010 1.80 (0.17) 3.63 (0.34) 3016 3.02 (0.28) 5.11 (0.47) 3020 4.24 (0.39) 6.59 (0.61) 3026 5.46 (0.51) 8.07 (0.75) 3030 6.68 (0.62) 9.54 (0.89) 3036 7.90 (0.73) 11.02 (1.02) 3040 9.11 (0.85) 12.50 (1.16) 3046 10.33 (0.96) 13.98 (1.30) 3050 11.55 (1.07) 15.46 (1.44) 3056 12.77 (1.19) 16.94 (1.57) 3060 13.99 (1.30) 18.42 (1.71) 3610 2.30 (0.21) 4.40 (0.41) 3616 3.77 (0.35) 6.13 (0.57) 3620 5.24 (0.49) 7.86 (0.73) 3626 6.71 (0.62) 9.59 (0.89) 3630 8.18 (0.76) 11.31 (1.05) 3636 9.65 (0.90) 13.04 (1.21) 3640 11.12 (1.03) 14.77 (1.37) 3646 12.59 (1.17) 16.50 (1.53) 3650 14.05 (1.31) 18.23 (1.69) 3656 15.52 (1.44) 19.96 (1.85) 3660 16.99 (1.58) 21.69 (2.02) 4010 2.85 (0.27) 5.21 (0.48) 4016 4.57 (0.42) 7.19 (0.67) 4020 6.29 (0.58) 9.17 (0.85) 4026 8.01 (0.74) 11.15 (1.04) 4030 9.73 (0.90) 13.13 (1.22) 4036 11.45 (1.06) 15.11 (1.40) 4040 13.17 (1.22) 17.09 (1.59) 4046 14.88 (1.38) 19.07 (1.77) 4050 16.60 (1.54) 21.05 (1.96) 4056 18.32 (1.70) 23.03 (2.14) 4060 20.04 (1.86) 25.00 (2.32) 4610 3.45 (0.32) 6.07 (0.56) 4616 5.42 (0.50) 8.30 (0.77) 4620 7.38 (0.69) 10.53 (0.98) 4626 9.35 (0.87) 12.76 (1.19) 4630 11.32 (1.05) 14.99 (1.39) 4636 13.29 (1.23) 17.22 (1.60) • Dimensions in parentheses are in square meters. For picture, transom, half circle, quarter circle, circle and Springline™ window specifications, see pages 70-73. 82 PICTURE, TRANSOM & SPECIALTY WINDOWS • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. Picture, Transom and Specialty Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Vertical Section Stucco Exterior Horizontal Section Stucco Exterior Horizontal Section 3 1 ⁄8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1 3 ⁄8" (35) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 1 ⁄4" (6 ) Low-E Glasssill head Andersen® Extension Jamb Attachment Flange (optional) 1 11 ⁄16" (43) 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1" (25) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 1 ⁄ 8" (3 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄ 8" (3 ) 1 ⁄4" (6 ) Low-E Glasssill head 1 11 ⁄16" (43) Low-E Glass (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass1 3 ⁄8" (3 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) Low-E Glass jambjamb 1 3 ⁄4" (44) 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y 83 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES Picture, Transom and Specialty Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 In s e r t Vertical Section Existing Window Opening Horizontal Section Existing Window Opening 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Ex i s t i n g O p e n i n g Un o b s t r . Gl a s s 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 3 1 ⁄4" (83) 1 ⁄4" (6 ) Low-E Glass Andersen® Exterior Sill Extender Trim (optional) sill head 1 11 ⁄16" (43) Low-E Glass (79)(79) 3 1 ⁄8" Window Dimension Width Existing Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb 1 3 ⁄4" (44) Vertical Section Existing Framed Opening Horizontal Section Existing Framed Opening 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Low-E Glasssill head Andersen® Extension Jamb Attachment Flange (optional) 1 11 ⁄16" (43) Low-E Glass (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) No F l a n g e Vertical Section Existing Aluminum Frame Window Opening Horizontal Section Existing Aluminum Frame Window Opening sill head 1 3 ⁄4" (4 4 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r u s t e d Gl a s s 3 1 ⁄4" (83) 3 ⁄16 " (5 ) 1 3 ⁄4" (4 4 ) 3 ⁄16 " (5 ) 1 5 ⁄ 8" (4 1 ) 3 ⁄8" (10) 1 5 ⁄ 8" (4 1 ) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Low-E Glass Andersen® Interior Flat Trim (44)(44) 1 3 ⁄4" Window Dimension Width Existing Opening 1 3 ⁄4"Unobstr. Glass 3 1 ⁄4" (8 3 ) 3 ⁄16" (5) 3 ⁄16" (5) 3 ⁄8" (1 0 ) 1 5 ⁄8" (41) 1 5 ⁄8" (41) jambjamb 1 3 ⁄4" (44) Low-E Glass Andersen® Interior Flat Trim • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Fl u s h F i n * Installation accessories are available for windows with insert and flush fin frames; see page 120. See pages 88-93 for joining details. 84 PICTURE, TRANSOM & SPECIALTY WINDOWS Vertical Section Stucco Exterior Horizontal Section Stucco Exterior 1" F l a n g e S e t b a c k W i t h S t u c c o K e y 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1" (25) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 1 ⁄ 8" (3 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄ 8" (3 ) 1 ⁄4" (6 ) Low-E Glass sill head Sill Stop to Suboor Dimension 1 3 ⁄4" (44)(79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 1" (2 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄8" (3)1 ⁄8" (3) 1 ⁄4" (6) Low-E Glass jambjamb 1 11 ⁄16" (43) Twin and Triple Transom Window Details – New Construction Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Horizontal Section 1 3/8" F l a n g e S e t b a c k 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1 3 ⁄8" (35) 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Low-E Glass sill head Andersen® Extension Jamb Attachment Flange (optional) Sill Stop to Suboor Dimension 1 3 ⁄4" (44)(79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass1 3 ⁄8" (3 5 ) 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) Low-E Glass jambjamb Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete window installation as shown but may not be included with window. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. Horizontal Section Twin/Triple Transom 6 3 ⁄4" (171) In t e g r a l 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES 85 Twin and Triple Transom Window Details – Replacement Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Vertical Section Existing Window Opening Horizontal Section Existing Window Opening In s e r t 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Ex i s t i n g O p e n i n g Un o b s t r . Gl a s s 1 ⁄4" (6 ) 3 1 ⁄8" (7 9 ) 3 1 ⁄4" (83) 1 ⁄4" (6 ) Low-E Glass Andersen® Exterior Sill Extender Trim (optional) sill head Sill Stop to Suboor Dimension 1 3 ⁄4" (44) Low-E Glass (79)(79) 3 1 ⁄8" Window Dimension Width Existing Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb 1 3 ⁄4" (44) Vertical Section Existing Framed Opening Horizontal Section Existing Framed Opening 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 3 1 ⁄4" (83) 1 ⁄4" (6 ) 3 1 ⁄ 8" (7 9 ) 1 ⁄4" (6 ) Low-E Glasssill head Andersen® Extension Jamb Attachment Flange (optional) 1 11 ⁄16" (43) Low-E Glass (79)(79) 3 1 ⁄8" Window Dimension Width Minimum Rough Opening 3 1 ⁄8"Unobstr. Glass 3 1 ⁄4" (8 3 ) 1 ⁄4" (6) 1 ⁄4" (6) jambjamb Andersen® Extension Jamb Attachment Flange (optional) 1 3 ⁄4" (44) No F l a n g e Integral detail shown on page 85. Installation accessories are available for windows with insert and flush fin frames; see page 120. See pages 88-93 for joining details. Vertical Section Existing Aluminum Frame Window Opening Horizontal Section Existing Aluminum Frame Window Opening sill head 3 1 ⁄ 8" (7 9 ) Wi n d o w D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t . Gl a s s 3 1 ⁄4" (83) 3 ⁄16 " (5 ) 3 1 ⁄8" (7 9 ) 3 ⁄16 " (5 ) 1 5 ⁄ 8" (4 1 ) 3 ⁄8" (10) 1 5 ⁄ 8" (4 1 ) Sill Stop to Suboor Dimension 1 3 ⁄4" (44) 1 3 ⁄8" (35) Low-E Glass Andersen® Interior Flat Trim Window Dimension Width Existing Opening 3 1 ⁄4" (8 3 ) 3 ⁄16" (5) 3 ⁄16" (5) 3 ⁄ 8" (1 0 ) 1 5 ⁄8" (41) 1 5 ⁄8" (41) jambjamb 1 3 ⁄4" (44) (79)(79) 3 1 ⁄8"3 1 ⁄8"Unobstr. Glass Low-E Glass Andersen® Interior Flat Trim Fl u s h F i n * 86 PICTURE, TRANSOM & SPECIALTY WINDOWS 87 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 100 SERIES • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual product or join in the combination. • Dimensions in parentheses are in millimeters. Casement to Casement (Lock Jamb to Lock Jamb) Casement to Casement (Hinge Jamb to Hinge Jamb) Casement to Casement (Lock Jamb to Stationary Jamb) Single-Hung to Single-Hung Single-Hung to Picture Casement to Picture (Casement Lock Jamb) Casement to Picture (Casement Hinge Jamb) Awning to Awning Awning to Picture 1 ⁄2" (13) (171) 6 3 ⁄4" Overall Window Dimension Width – Sum of individual window widths plus 1 ⁄2" (13) per join. Overall Minimum Rough Opening Width – Overall window dimension width plus 3 ⁄4" (19). The addition of joining materials will affect the overall rough opening dimension. See page 121. Vertical (ribbon) Fiberglass Joining Details – Non-Reinforced Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Gliding to Gliding (Active Jamb to Stationary Jamb) Gliding to Picture (Gliding Stationary Jamb) Picture to Picture 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" Gliding to Picture (Gliding Active Jamb) 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" Casement to Casement (Stationary Jamb to Stationary Jamb) 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" FRAME TYPES: 1 3/8" Flange Setback, 1" Flange Setback With Stucco Key, No Flange and Insert 88 WINDOW JOINING DETAILS 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" Picture/Specialty Over Casement Casement Over Picture Overall Window Dimension Width – Sum of individual window widths plus 1 ⁄2" (13) per join. Overall Minimum Rough Opening Width – Overall window dimension width plus 3 ⁄4" (19). The addition of joining materials will affect the overall rough opening dimension. See page 121. Horizontal (stack) Fiberglass Joining Details – Non-Reinforced Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Picture/Specialty Over Picture 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" Picture/Specialty Over Awning Awning Over Picture Transom Over Casement Transom Over Awning Picture/Specialty Over GlidingPicture/Specialty Over Single-Hung Transom Over Single-Hung 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" FRAME TYPES: 1 3/8" Flange Setback, 1" Flange Setback With Stucco Key, No Flange and Insert Transom Over PictureTransom Over Gliding 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual product or join in the combination. • Dimensions in parentheses are in millimeters. For more information on joining, refer to the Combination Designs section starting on page 107. 89 10 0 S e r i e s W i n d o w Jo i n i n g D e t a i l s 100 SERIES Casement to Casement (Lock Jamb to Lock Jamb) Casement to Casement (Hinge Jamb to Hinge Jamb) Casement to Casement (Lock Jamb to Stationary Jamb) Single-Hung to Single-Hung Single-Hung to Picture Casement to Picture (Casement Lock Jamb) Casement to Picture (Casement Hinge Jamb) Awning to Awning Awning to Picture 1 ⁄2" (13) (171) 6 3 ⁄4" Overall Window Dimension Width – Sum of individual window widths plus 1 ⁄2" (13) per join. Overall Minimum Rough Opening Width – Overall window dimension width plus 3 ⁄4" (19). The addition of joining materials will affect the overall rough opening dimension. See page 121. Vertical (ribbon) Fiberglass Joining Details – Non-Reinforced Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Gliding to Gliding (Active Jamb to Stationary Jamb) Gliding to Picture (Gliding Stationary Jamb) Picture to Picture 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (102) 4" 1 ⁄2" (13) (137) 5 3 ⁄8" 1 ⁄2" (13) (137) 5 3 ⁄8" 1 ⁄2" (13) (137) 5 3 ⁄8" 1 ⁄2" (13) (171) 6 3 ⁄4" Gliding to Picture (Gliding Active Jamb) 1 ⁄2" (13) (137) 5 3 ⁄8" 1 ⁄2" (13) (137) 5 3 ⁄8" Casement to Casement (Stationary Jamb to Stationary Jamb) 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (171) 6 3 ⁄4" 1 ⁄2" (13) (137) 5 3 ⁄8" FRAME TYPE: Flush Fin* • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on pages 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual product or join in the combination. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. 90 WINDOW JOINING DETAILS 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" Picture/Specialty Over Casement Casement Over Picture Overall Window Dimension Width – Sum of individual window widths plus 1 ⁄2" (13) per join. Overall Minimum Rough Opening Width – Overall window dimension width plus 3 ⁄4" (19). The addition of joining materials will affect the overall rough opening dimension. See page 121. Horizontal (stack) Fiberglass Joining Details – Non-Reinforced Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Transom Over Gliding 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" Picture/Specialty Over Awning Awning Over Picture Transom Over Casement Transom Over Awning Picture/Specialty Over GlidingPicture/Specialty Over Single-Hung Transom Over Single-Hung 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄ 8" 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄8" 1 ⁄ 2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 7 1 ) 6 3 ⁄4" 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄ 8" 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄ 8" 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄ 8" 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄8" Transom Over Picture 1 ⁄2" (1 3 ) (1 3 7 ) 5 3 ⁄8" Picture/Specialty Over Picture 1 ⁄2" (1 3 ) (1 0 2 ) 4" FRAME TYPE: Flush Fin* • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual product or join in the combination. • Dimensions in parentheses are in millimeters. *Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. For more information on joining, refer to the Combination Designs section starting on page 107. 91 10 0 S e r i e s W i n d o w Jo i n i n g D e t a i l s 100 SERIES • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual product or join in the combination. • Dimensions in parentheses are in millimeters. Casement to Casement (Lock Jamb to Lock Jamb) Casement to Casement (Hinge Jamb to Hinge Jamb) Casement to Casement (Lock Jamb to Stationary Jamb) Single-Hung to Single-Hung Single-Hung to Picture Casement to Picture (Casement Lock Jamb) Casement to Picture (Casement Hinge Jamb) Awning to Awning Awning to Picture 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" Overall Window Dimension Width – Sum of individual window widths plus 3 ⁄4" (19) per join. Overall Minimum Rough Opening Width – Overall window dimension width plus 3 ⁄4" (19). The addition of joining materials will affect the overall rough opening dimension. See page 121. Vertical (ribbon) Easy Connect Fiberglass Joining Details – Reinforced Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Gliding to Gliding (Active Jamb to Stationary Jamb) Gliding to Picture (Gliding Stationary Jamb) Picture to Picture 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" Gliding to Picture (Gliding Active Jamb) 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" Casement to Casement (Stationary Jamb to Stationary Jamb) 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" (42) 3 ⁄4" (19) (178) 7" 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19) (178) 7" (42) 1 5 ⁄8" (52) 2 1 ⁄16" FRAME TYPES: 1 3/8" Flange Setback, 1" Flange Setback With Stucco Key and No Flange 92 WINDOW JOINING DETAILS 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" • Light-colored areas are parts included with window. Dark-colored areas are additional Andersen® parts required to complete window assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or join in the combination. • Dimensions in parentheses are in millimeters. Picture/Specialty Over Casement Casement Over Picture Overall Window Dimension Width – Sum of individual window widths plus 3 ⁄4" (19) per join. Overall Minimum Rough Opening Width – Overall window dimension width plus 3 ⁄4" (19). The addition of joining materials will affect the overall rough opening dimension. See page 121. Horizontal (stack) Easy Connect Fiberglass Joining Details – Reinforced Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Picture/Specialty Over Picture 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" 2 1 ⁄16" (52) Picture/Specialty Over Awning Awning Over Picture Transom Over Casement Transom Over Awning Picture/Specialty Over GlidingPicture/Specialty Over Single-Hung Transom Over Single-Hung 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19)(178)(42) 1 5 ⁄8" (52) 2 1 ⁄16" 7" 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" 3 ⁄4" (19)(178) 7"(42) 1 5 ⁄8" (52) 2 1 ⁄16" Transom Over Gliding Transom Over Picture FRAME TYPES: 1 3/8" Flange Setback, 1" Flange Setback With Stucco Key and No Flange 3 ⁄4" (19)(178)(42) 1 5 ⁄8" (52) 2 1 ⁄16" 7" 3 ⁄4" (19)(178)(42) 1 5 ⁄8" (52) 2 1 ⁄16" 7" For more information on joining, refer to the Combination Designs section starting on page 107. 10 0 S e r i e s W i n d o w Jo i n i n g D e t a i l s 100 SERIES 93 Casement Windows Custom Sizes and Specification Formulas 100 Series custom-size windows are available in 1 ⁄8" (3) increments between minimum and maximum widths and heights shown. Some restrictions apply. CUSTOM WIDTHS CU S T O M H E I G H T S 17 1 ⁄2" (445) 35 1 ⁄2" (902)to 23 1 ⁄ 2" (5 9 7 ) 71 1 ⁄ 2" (1 8 1 6 ) to Clear Opening Width = window width - 12.103" (307) wash mode* Width = window width - 7.790" (198) widest clear opening* Height = window height - 5.694" (145) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = window width - 7.964" (202) Height = window height - 5.694" (145) Unobst. Glass Width = window width - 6.250" (159) Height = window height - 6.250" (159) Single CUSTOM WIDTHS CU S T O M H E I G H T S 35 1 ⁄2" (902) 71 1 ⁄2" (1816)to 23 1 ⁄ 2" (5 9 7 ) 71 1 ⁄2" (1 8 1 6 ) to Clear Opening Width = (window width ÷ 2) - 12.353" (314) wash mode* Width = (window width ÷ 2) - 8.040" (204) widest clear opening* Height = window height - 5.694" (145) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = window width - 16.428" (417) Height = window height - 5.694" (145) Unobst. Glass Single Sash Width = (window width ÷ 2) - 6.50" (165) Total Sash Width = window width - 13.000" (330) Height = window height - 6.250" (159) Twin *Widest clear opening hinge will be applied, based on window size, if it allows the window to meet or exceed clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Hinge type cannot be specified. • Clear Opening formulas provide dimensions for determining area available for egress. Vent Opening formulas provide dimensions for determining area available for passage of air. Minimum R.O. (minimum rough opening) formulas provide minimum rough opening width and height dimensions. Unobst. Glass (unobstructed glass) formulas provide dimensions for determining area available for passage of light. • Dimensions in parentheses are in millimeters. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. *Widest clear opening hinge will be applied, based on window size, if it allows the window to meet or exceed clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). Hinge type cannot be specified. 94 WINDOW CUSTOM SIZES CUSTOM WIDTHS CU S T O M H E I G H T S 35 1 ⁄2" (902) 71 1 ⁄2" (1816)to 17 1 ⁄2" (4 4 5 ) 35 1 ⁄ 2" (9 0 2 ) to Clear Opening Width = (window width ÷ 2) - 5.944" (151) Depth = 8.000" (203) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = (window width ÷ 2) - 5.944" (151) Depth = 8.000" (203) Unobst. Glass Single Sash Width = (window width ÷ 2) - 6.50" (165) Total Sash Width = window width - 13.000" (330) Height = window height - 6.250" (159) Single Twin Picture Window Over Awning Awning Windows Clear Opening Width = window width - 5.694" (145) Depth = 8.000" (203) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = window width - 5.694" (145) Depth = 8.000" (203) Unobst. Glass Width = window width - 6.250" (159) Total Sash Height = window height - 13.000" (330) Contact your Andersen supplier for unobstructed glass height dimension of individual stationary sash or venting sash. CUSTOM WIDTHS CU S T O M H E I G H T S 17 1 ⁄2" (445) 47 1 ⁄2" (1207)to 47 1 ⁄2" (1 2 0 7 ) 95 1 ⁄ 2" (2 4 2 6 ) to Contact your Andersen supplier for minimum and maximum height dimensions for lower venting sash. CUSTOM WIDTHS CU S T O M H E I G H T S 17 1 ⁄2" (445) 47 1 ⁄2" (1207)to 17 1 ⁄ 2" (4 4 5 ) 35 1 ⁄ 2" (9 0 2 ) to Clear Opening Width = window width - 5.694" (145) Depth = 8.000" (203) Minimum R.O. Vent Opening Width = window width - 5.694" (145) Depth = 8.000" (203) Unobst. Glass Width = window width - 6.250" (159) Height = window height - 6.250" (159) 1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) • Awning windows do not meet clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). • Awning windows do not meet clear opening area of 5.7 sq. ft. or 0.53 m2, clear opening width of 20" (508) and clear opening height of 24" (610). • Clear Opening formulas provide dimensions for determining area available for egress. Vent Opening formulas provide dimensions for determining area available for passage of air. Minimum R.O. (minimum rough opening) formulas provide minimum rough opening width and height dimensions. Unobst. Glass (unobstructed glass) formulas provide dimensions for determining area available for passage of light. • Dimensions in parentheses are in millimeters. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. 95 10 0 S e r i e s W i n d o w Cu s t o m S i z e s 100 SERIES CUSTOM WIDTHS CU S T O M H E I G H T S 35 1 ⁄2" (902) 95 1 ⁄2" (2426)to 23 1 ⁄ 2" (5 9 7 ) 71 1 ⁄ 2" (1 8 1 6 ) to Clear Opening Width = (window width ÷ 2) - 3.750" (95) Height = (window height ÷ 2) - 3.711" (94)) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Equal Sash Ratio Width = window width - 3.500" (89) Height = (window height ÷ 2) - 3.711" (94) Unobst. Glass Single Sash Width = (window width ÷ 2) - 6.500" (165) Total Sash Width = window width - 13.000" (330) Fixed Sash Height = (window height ÷ 2) - 4.184" (106) Venting Sash Height = (window height ÷ 2) - 4.226" (107) Total Sash Height = window height - 8.410 " (214) CUSTOM WIDTHS CU S T O M H E I G H T S 71 1 ⁄2" (1 8 1 6 ) 53 1 ⁄2" (1359) 143 1 ⁄2" (3645)to 23 1 ⁄ 2" (5 9 7 ) to Clear Opening Width = (window width ÷ 3) - 3.833" (97) Height = (window height ÷ 2) - 3.711" (94) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Equal Sash Ratio Width = window width - 11.500" (292) Height = (window height ÷ 2) - 3.711" (94) Unobst. Glass Single Sash Width = (window width ÷ 3) - 6.583" (167) Total Sash Width = window width - 19.750" (502) Fixed Sash Height = (window height ÷ 2) - 4.184" (106) Venting Sash Height = (window height ÷ 2) - 4.226" (107) Total Sash Height = window height - 8.410" (214) Twin Triple Single-Hung Windows CUSTOM WIDTHS CU S T O M H E I G H T S 17 1 ⁄2" (445) 47 1 ⁄2" (1207)to 23 1 ⁄ 2" (5 9 7 ) 77 1 ⁄ 2" (1 9 6 9 ) to Clear Opening Width = window width - 3.500" (89) Height = (window height ÷ 2) - 3.711" (94) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Equal Sash Ratio Width = window width - 3.500" (89) Height = (window height ÷ 2) - 3.711" (94) Unobst. Glass Equal Sash Ratio Width = window width - 6.250" (159) Fixed Sash Height = (window height ÷ 2) - 4.184" (106) Venting Sash Height = (window height ÷ 2) - 4.226" (107) Total Sash Height = window height - 8.410 " (214) Equal Sash Ratio • Drywall pass-through window is available for custom-size windows wider than 23 1/2" (597) and taller than 53 1/2" (1359). Not available for windows with flush fin frame. • Windows with a 3:2 reverse cottage sash ratio are available in custom sizes from 17 1/2" (445) to 47 1/2" (1207) in width to 29 1/2" (749) to 77 1/2" (1969) in height. For area and opening specification formulas, visit andersenwindows.com. Windows with a height greater than 77 1/2" (1969) are only available with a 2:1 reverse cottage sash ratio.* • Clear Opening formulas provide dimensions for determining area available for egress. Vent Opening formulas provide dimensions for determining area available for passage of air. Minimum R.O. (minimum rough opening) formulas provide minimum rough opening width and height dimensions. Unobst. Glass (unobstructed glass) formulas provide dimensions for determining area available for passage of light. • Dimensions in parentheses are in millimeters. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. *Window heights that require a 2:1 reverse cottage sash ratio are available in custom sizes from 17 1/2" (445) to 47 1/2" (1207) in width to 77 5/8" (1972) to 89 1 ⁄2" (2273) in height. For area and opening specifications, contact your Andersen supplier. CUSTOM WIDTHS CU S T O M H E I G H T S 11 1 ⁄2" (292) 95 1 ⁄2" (2426)to 11 1 ⁄ 2" (2 9 2 ) 95 1 ⁄ 2" (2 4 2 6 ) to Either height or width must be 71 1 ⁄2" (1816)or less. 96 WINDOW CUSTOM SIZES 2:1 sash ratio is not available for heights 6'-5 1/2" (1969) and less. Clear Opening Width = (window width ÷ 4) - 2.976" (76) Height = window height - 3.500" (89) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = (window width ÷ 2) - 5.952" (151) Height = window height - 3.500" (89) Unobst. Glass Fixed Sash Width = (window width ÷ 2) - 1.868" (47) Venting Sash Width = (window width ÷ 4) - 4.351" (111) Total Sash Width = window width - 10.570" (268) Height = window height - 6.250" (159) Gliding Windows Active-Stationary-Active 1:2:1 Sash Ratio Clear Opening Width = (window width ÷ 3) - 5.164" (131) Height = window height - 3.500" (89) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = (window width ÷ 3) - 5.164" (131) Height = window height - 3.500" (89) Unobst. Glass Fixed Sash Width = (window width ÷ 3) - 3.496" (89) Venting Sash Width = (window width ÷ 3) - 3.537" (90) Total Sash Width = window width - 10.570 " (268) Height = window height - 6.250" (159) Active-Stationary-Active 1:1:1 Equal Sash Ratio CUSTOM WIDTHS CU S T O M H E I G H T S 23 1 ⁄2" (597) 71 1 ⁄2" (1816)to 11 1 ⁄ 2" (2 9 2 ) 71 1 ⁄ 2" (1 8 1 6 ) to Clear Opening Width = (window width ÷ 2) - 3.711" (94) Height = window height - 3.500" (89) Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Vent Opening Width = (window width ÷ 2) - 3.711" (94) Height = window height - 3.500" (89) Unobst. Glass Fixed Sash Width = (window width ÷ 2) - 4.184" (106) Venting Sash Width = (window width ÷ 2) - 4.226" (107) Total Sash Width = window width - 8.410 " (214) Height = window height - 6.250" (159) Active-Stationary or Stationary-Active CUSTOM WIDTHS CU S T O M H E I G H T S 59 1 ⁄2" (1511) 143 1 ⁄2" (3645)to 17 1 ⁄2" (4 4 5 ) 71 1 ⁄ 2" (1 8 1 6 ) to CU S T O M H E I G H T S 17 1 ⁄ 2" (4 4 5 ) 71 1 ⁄ 2" (1 8 1 6 ) to CUSTOM WIDTHS 47 1 ⁄2" (1207) 101 1 ⁄2" (2578)to • Clear Opening formulas provide dimensions for determining area available for egress. Vent Opening formulas provide dimensions for determining area available for passage of air. Minimum R.O. (minimum rough opening) formulas provide minimum rough opening width and height dimensions. Unobst. Glass (unobstructed glass) formulas provide dimensions for determining area available for passage of light. • Dimensions in parentheses are in millimeters. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. 97 100 SERIES CUSTOM WIDTHS CU S T O M H E I G H T S 11 1 ⁄2" (292) 95 1 ⁄2" (2426)to 11 1 ⁄ 2" (2 9 2 ) 95 1 ⁄ 2" (2 4 2 6 ) to Either height or width must be 71 1 ⁄2" (1816)or less. CUSTOM WIDTHS CU S T O M H E I G H T S 35 1 ⁄2" (902) 95 1 ⁄2" (2426)to 11 1 ⁄ 2" (2 9 2 ) 23 1 ⁄ 2" (5 9 7 ) to CUSTOM WIDTHS CU S T O M H E I G H T S 53 1 ⁄2" (1359) 143 1 ⁄2" (3645)to 11 1 ⁄ 2" (2 9 2 ) 23 1 ⁄ 2" (5 9 7 ) to Picture Windows Twin Triple transom windows with unequal sash are not available in custom sizes. • Minimum R.O. (minimum rough opening) formulas provide minimum rough opening width and height dimensions. Unobst. Glass (unobstructed glass) formulas provide dimensions for determining area available for passage of light. • Dimensions in parentheses are in millimeters. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Unobst. Glass 1 3/8" & 1" Flange Setback, No Flange and Insert Frames Width = window width - 6.250" (159) Height = window height - 6.250" (159) Flush Fin Frame Width = window width - 3.500" (89) Height = window height - 3.500" (89) Transom Windows Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Unobst. Glass Twin Single Sash Width = (window width ÷ 2) - 6.500" (165) Total Sash Width = window width - 13.000" (330) Height = window height - 6.250" (159) Triple Minimum R.O.1 3/8" & 1" Flange Setback Frames Width = window width + 1/2" (13) Height = window height + 1/2" (13) Insert & Flush Fin Frames Width = window width + 3/8" (10) Height = window height + 3/8" (10) Unobst. Glass Triple Single Sash Width = (window width ÷ 3) - 6.583" (167) Total Sash Width = window width - 19.750" (502) Height = window height - 6.250" (159) CUSTOM WIDTHS CU S T O M H E I G H T S 11 1 ⁄2" (292) 95 1 ⁄2" (2426)to 11 1 ⁄ 2" (2 9 2 ) 95 1 ⁄ 2" (2 4 2 6 ) to Either height or width must be 71 1 ⁄2" (1816) or less. 98 WINDOW CUSTOM SIZES Dimensions in parentheses are in millimeters. Gliding Patio Doors Table of Sizes ........................................... 101 Specifications ........................................... 101 Grille Patterns ........................................... 102 Door Details ............................................. 102 Patio Door Sidelights & Transoms Table of Sizes ........................................... 103 Specifications ........................................... 103 Grille Patterns ........................................... 102 Sidelight & Transom Details .................. 104 Joining Details ................................................ 105 Custom Sizes ................................................ 106 Combination Designs ................................... 107 Product Performance ..................................... 111 PATIO DOORS in 1⁄8" (3) increments CUSTOM SIZING 100 SERIES G E D Dark **Bronze** Dark Bronze BlackSandtoneTerratone EXTERIORS & INTERIORS White EXTERIOR COLORS **Black****Sandtone**White INTERIOR COLORS FEATURES GLIDING PATIO DOORS A B C F FRAME A The frame is constructed with Fibrex® composite material. This construction produces a rigid frame. The durable, low-maintenance finish won’t fade, flake, blister or peel.* Factory-assembled doors arrive at the job site ready to install. B Dual felt weatherstrip, applied on the inside pocket of both side jambs and the head jamb, creates a positive seal between the frame and panels. The result is a long-lasting,* energy-efficient barrier against wind, water and dust. A full-length combination weatherstrip/interlock system provides a flexible seal at the meeting stile. Three frame options include: • 1 3 ⁄8" (35) flange setback for new construction siding applications. An integral rigid vinyl flange helps seal the unit to the structure. • 1" (25) flange setback with stucco key for new construction stucco applications. An integral rigid vinyl flange helps seal the unit to the structure. • No flange for door replacement in an existing framed opening. PANEL C Fibrex material construction provides long-lasting performance.* The panel, finished with a durable capping, provides maximum protection and a matte low-maintenance finish. D Dual corrosion-resistant* ball- bearing rollers on the operating door panel provide smooth operation with self-contained leveling adjusters. The rollers have deep grooves to increase engagement with the roller track and resist lateral movement. Metal reinforcement inserted into the panel stiles provides additional stability. SILL E The one-piece sill design with weep holes located on the sill exterior provides superior water management. The heavy-gauge PVC construction is wear resistant and neutral gray in color. F The roller track has a stainless steel cap that resists denting for smooth, reliable operation. GLASS Glass spacers are available in stainless steel and black. Stainless steel glass spacer shown. A glazing bead and silicone provide superior weathertightness and durability. H High-Performance options include: • Low-E SmartSun™ tempered glass • Low-E SmartSun HeatLock® tempered glass • Low-E tempered glass • Low-E HeatLock tempered glass • Low-E Sun tempered glass • Low-E PassiveSun® tempered glass • Low-E PassiveSun HeatLock tempered glass • Clear dual-pane tempered glass Additional glass options are available. Contact your Andersen supplier. A removable translucent film helps shield the glass from damage during delivery and construction, and simplifies finishing at the job site. Patterned Glass Patterned glass options are available. See page 13 for more details. HARDWARE Locking System A two-point locking system engages a steel receiver plate that’s secured into the side jamb. This provides enhanced security and a weathertight seal, with the operating panel pulled tightly into the jamb. *Visit andersenwindows.com/warranty for details. **Products with Sandtone, dark bronze and black interiors have matching exteriors. Dimensions in parentheses are in millimeters. Printing limitations prevent exact replication of colors and finishes. See your Andersen supplier for actual color and finish samples. HARDWARE Exterior handle color matches the door’s exterior. Interior handle color matches the door’s interior. Exterior handle shown in dark bronze. Interior handle shown in white. See exterior and interior color swatches shown above. ACCESSORIES Sold Separately HARDWARE Auxiliary Foot Lock Provides an extra measure of security when the door is in a locked position. Available in colors that coordinate with the door’s interior. GRILLES Grilles are available in a variety of configurations. See page 14 for details. INSECT SCREENS Insect screens have charcoal gray fiberglass screen mesh. The latch mechanism is contained within the insect screen handle for easy operation. Frames are available in colors to match the door’s exterior. SIDELIGHTS & TRANSOMS Patio door sidelights and transoms are available. See page 103. TULSA Standard Handle Bold name denotes finish shown. Exterior Interior Exterior Interior Antique Brass Black Bright Brass Satin Nickel AFTON Optional Handle Antique Brass Bright Brass Black Satin Nickel 100 PATIO DOORS Custom-size patio doors are available in 1 ⁄8" (3) increments. See page 106 for custom sizes and specifications. Arrow indicates direction of panel operation as viewed from the exterior. To meet or exceed a clear opening width of 32" (813), select a door width that requires a rough opening width of 6'-6" (1981) or greater. Grille patterns and details shown on page 102. • Door Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. *Meets or exceeds a 32" (813) clear opening width. x x 68 x x 611 x x 80 6' - 7 1/2" 6' - 8 " 71 1/4" 6' - 1 0 1/2" 6' - 1 1 " 74 1/4" 7' - 1 1 1/2" 8' - 0 " 87 1/4" Do o r D i m e n s i o n Un o b s t r u c t e d G l a s s Mi n i m u m Ro u g h O p e n i n g (2 0 1 9 ) (2 0 3 2 ) (18 1 0 ) (20 9 6 ) (2 1 0 8 ) (18 8 6 ) (2 4 2 6 ) (2 4 3 8 ) (22 1 6 ) 5068L 50611L 5080L 6068L 60611L 6080L 5068R 50611R 5080R 6068R 60611R 6080R 8068L* 80611L* 8080L* 8068R* 80611R* 8080R* Door Dimension Minimum Rough Opening Table of Gliding Patio Doors Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 24 1/8" 4'-11 1/4" 5'-0"6'-0" 5'-11 1/4" 30 1/8" 3 heights 24 1/8" 4'-11 1/4" 5'-0"6'-0" 5'-11 1/4" 30 1/8" 42 1/8" 7'-11 1/4" 8'-0" 42 1/8" 7'-11 1/4" 8'-0" 3 heights Door Dimension Minimum Rough Opening Unobstructed Glass (width of single panel only) (1505) (1524) (613) (1810) (1829) (765) (1505) (1524) (613) (1810) (1829) (765) (2419) (2438) (1070) (2419) (2438) (1070) Patio Door Heights Gliding Patio Door Opening and Area Specifications Door Number Clear Opening Area* Sq. Ft./(m2) Clear Opening in Full Open Position Glass Area Sq. Ft./(m2) Vent Area* Sq. Ft./(m2) Overall Door Area Sq. Ft./(m2)Width* Inches/(mm) Height Inches/(mm) 5068 12.38 (1.15) 23 1/2"(597) 75 7/8"(1927) 23.87 (2.22) 12.38 (1.15) 32.71 (3.04) 6068 15.54 (1.44) 29 1/2"(749) 75 7/8"(1927) 31.27 (2.91) 15.54 (1.44) 39.34 (3.65) 8068 21.87 (2.03) 41 1/2"(1054) 75 7/8"(1927) 43.14 (4.01) 21.87 (2.03) 52.59 (4.89) 50611 12.87 (1.20) 23 1/2"(597) 78 7/8"(2003) 52.79 (4.90) 12.87 (1.20) 33.95 (3.15) 60611 16.16 (1.50) 29 1/2"(749) 78 7/8"(2003) 32.58 (3.03) 16.16 (1.50) 40.82 (3.79) 80611 22.73 (2.11) 41 1/2"(1054) 78 7/8"(2003) 44.96 (4.18) 22.73 (2.11) 54.57 (5.07) 5080 14.99 (1.39) 23 1/2"(597) 91 7/8"(2334) 31.02 (2.88) 14.99 (1.39) 39.29 (3.65) 6080 18.82 (1.75) 29 1/2"(749) 91 7/8"(2334) 38.29 (3.56) 18.82 (1.75) 47.25 (4.39) 8080 26.48 (2.46) 41 1/2"(1054) 91 7/8"(2334) 52.83 (4.91) 26.48 (2.46) 63.17 (5.87) • Dimensions in parentheses are in millimeters or square meters. *For doors with Tulsa hardware only. Contact your Andersen supplier for doors with Afton hardware. 6068 L Door Rough Opening LeftGliding 6068 R Door RoughOpening RightGliding Order Designation Description Viewed from the exterior. 6068 L Door Rough Opening LeftGliding 6068 R Door RoughOpening RightGliding 101 10 0 S e r i e s G l i d i n g Pa t i o D o o r s 100 SERIES Gliding Patio Door Details Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Vertical Section Stucco Exterior Horizontal Section Stucco Exterior Horizontal Section Prairie A Colonial Fractional Short Gliding Patio Doors and Patio Door Sidelights Patio Door Transoms Grille Patterns 4" (1 0 2 ) Do o r D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g 1 3 ⁄8" (35) 5 1 ⁄8" (130) 4 1 ⁄ 8" (1 0 5 ) 1 ⁄ 2" (1 3 ) Un o b s t r u c t e d G l a s s 7⁄ 8" (2 2 ) 1 1 ⁄4" (3 2 ) Low-E Glass Insect Screen sill head 5 3 ⁄16" (132) 1 1 ⁄ 8" (2 9 ) 1 7⁄8" (48) 2 1 ⁄4" (57) 1 3 ⁄4" (44) Clear Opening 4" (1 0 2 ) Do o r D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g 1" (25) 5 1 ⁄8" (130) 4 1 ⁄ 8" (1 0 5 ) Un o b s t r u c t e d G l a s s 1 ⁄8" (3 ) 1 ⁄ 2" (1 3 ) 1 1 ⁄8" (2 9 ) 7 ⁄8" (2 2 ) 1 3 ⁄ 8" (3 5 ) 5 3 ⁄16" (132) Low-E Glass Insect Screen head sill head 1 7⁄8" (48) 2 1 ⁄4" (57) 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen (102)(102) Door Dimension Width Minimum Rough Opening 4"Unobstructed Glass1 3 ⁄ 8" (3 5 ) 5 1 ⁄ 8" (1 3 0 ) 3 ⁄8" (10) 3 ⁄8" (10) (73) 2 7⁄8"4"Unobstructed Glass jambjamb meeting stile active panelstationary panel 1 3 ⁄4" (44) Clear Opening Low-E Glass Insect Screen 3 ⁄8" (10) 1 ⁄8" (3)1 ⁄8" (3) 3 ⁄8" (10) 1" (2 5 ) 5 1 ⁄ 8" (1 3 0 ) (102)(102) Door Dimension Width Minimum Rough Opening 4"Unobstructed Glass (73) 2 7⁄8"4"Unobstructed Glass jambjambjambjamb meeting stile active panelstationary panel 1 3 ⁄4" (44) Clear Opening See page 105 for joining details. • Light-colored areas are parts included with door. Dark-colored areas are additional Andersen® parts required to complete door assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete door installation as shown but may not be included with door. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y Number of lights and overall pattern varies with door size. Patterns may not be available in all configurations or sizes. Specified equal light and custom patterns are also available. For specified equal light, specify number of same-size rectangles across or down. For more grille options, see page 14 or visit andersenwindows.com/grilles. Custom Example Specied Equal Light Examples Custom Example Specied Equal Light Examples 102 GLIDING PATIO DOORS 1313 1613 1316 1616 1320 1620 2013 2016 2020 2613 2616 2620 3013 3016 3020 4013 4016 4020 5013 5016 5020 6013 6016 6020 8013 8016 8020 1368 1668 13611 1380 16611 1680 2068 20611 2080 2668 26611 2680 3068 30611 3080 4068 40611 4080 Sidelight/Transom Dimension Minimum Rough Opening Table of Patio Door Sidelight and Transom Sizes Scale 1 ⁄8" (3) = 1'-0" (305) — 1:96 27 3/16" 2'-11 1/4" 3'-0" 39 3/16" 3'-11 1/4" 4'-0" 51 3/16" 4'-11 1/4" 5'-0"6'-0" 5'-11 1/4" 63 3/16" 9 3/16 " 1' - 5 1/4" 1' - 6 " 6 3/16 " 1' - 2 1/4" 1' - 3 " 15 1/16 " 1' - 1 1 1/4" 2' - 0 " 2'-5 1/4" 2'-6" 21 3/16"6 3/16" 1'-2 1/4" 1'-3" 15 3/16" 1'-11 1/4" 2'-0" 9 3/16" 1'-5 1/4" 1'-6" 87 3/16" 7'-11 1/4" 8'-0" 71 1/4" 6' - 7 1/2" 6' - 8 " 7' - 1 1 1/2" 8' - 0 " 87 1/4" 74 1/4" 6' - 1 0 1/2" 6' - 1 1 " CUSTOM WIDTHS — 14 1 ⁄4" to 47 1 ⁄4" CU S T O M H E I G H T S — 79 1 ⁄ 2" t o 95 1 ⁄ 2" Unobstructed Glass CU S T O M HE I G H T S — 14 1 ⁄4" t o 23 1 ⁄4" CUSTOM WIDTHS — 14 1 ⁄4" to 95 1 ⁄4" (895) (914) (691) (1200) (1219) (995) (1505) (1524) (1300) (1810) (1829) (1605) (43 8 ) (45 7 ) (23 3 ) (36 2 ) (3 8 1 ) (15 7 ) (59 1 ) (61 0 ) (38 6 ) (743) (762) (538) (362) (381) (157) (591) (610) (386) (438) (457) (233) (2419) (2438) (2215) (20 1 9 ) (20 3 2 ) (18 1 0 ) (24 2 6 ) (24 3 8 ) (22 1 6 ) (20 9 6 ) (21 0 8 ) (18 8 6 ) Patio Door Sidelight Area Specifications Sidelight Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1368 3.06 (0.28) 7.87 (0.73) 13611 3.19 (0.30) 8.16 (0.76) 1380 3.75 (0.35) 9.45 (0.88) 1668 4.55 (0.42) 9.52 (0.88) 16611 4.74 (0.44) 9.88 (0.92) 1680 5.57 (0.52) 11.44 (1.06) 2068 7.51 (0.70) 12.84 (1.19) 20611 7.83 (0.73) 13.32 (1.24) 2080 9.20 (0.85) 15.42 (1.43) 2668 10.48 (0.97) 16.15 (1.50) 26611 10.92 (1.01) 16.76 (1.56) 2680 12.84 (1.19) 19.40 (1.80) 3068 13.45 (1.25) 19.46 (1.81) 30611 14.02 (1.30) 20.20 (1.88) 3080 16.47 (1.53) 23.38 (2.17) 4068 19.39 (1.80) 26.09 (2.42) 40611 20.21 (1.88) 27.07 (2.51) 4080 23.74 (2.21) 31.34 (2.91) • Transom/Sidelight Dimension always refers to outside frame-to-frame dimension. • Minimum Rough Opening dimensions may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See page 121 for more details. • Dimensions in parentheses are in millimeters. Custom-size doors are available in 1 ⁄8" (3) increments. See page 106 for custom sizes and specifications. Grille patterns shown on page 102. Details shown on page 104. Patio Door Transom Area Specifications Transom Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 1313 0.27 (0.03) 1.41 (0.13) 1316 0.40 (0.04) 1.71 (0.16) 1320 0.65 (0.06) 2.30 (0.21) 1613 0.40 (0.04) 1.71 (0.16) 1616 0.59 (0.05) 2.07 (0.19) 1620 0.97 (0.09) 2.79 (0.26) 2013 0.65 (0.06) 2.30 (0.21) 2016 0.97 (0.09) 2.79 (0.26) 2020 1.61 (0.15) 3.75 (0.35) 2613 0.91 (0.09) 2.90 (0.27) 2616 1.35 (0.13) 3.50 (0.33) 2620 2.24 (0.21) 4.72 (0.44) 3013 1.17 (0.11) 3.49 (0.32) 3016 1.74 (0.16) 4.22 (0.39) 3020 2.87 (0.27) 5.69 (0.53) 4013 1.69 (0.16) 4.68 (0.43) 4016 2.50 (0.23) 5.66 (0.53) 4020 4.13 (0.39) 7.63 (0.71) • Dimensions in parentheses are in square meters. Patio Door Transom Area Specifications Transom Number Glass Area Sq. Ft./(m2) Overall Window Area Sq. Ft./(m2) 5013 2.20 (0.20) 5.86 (0.55) 5016 3.27 (0.30) 7.10 (0.66) 5020 5.40 (0.50) 9.57 (0.89) 6013 2.72 (0.25) 7.05 (0.66) 6016 4.03 (0.38) 8.54 (0.79) 6020 6.67 (0.62) 11.50 (1.07) 8013 3.75 (0.35) 9.43 (0.88) 8016 5.56 (0.52) 11.41 (1.06) 8020 9.20 (0.85) 15.38 (1.43) • Dimensions in parentheses are in square meters. 103 10 0 S e r i e s P a t i o D o o r Si d e l i g h t s & T r a n s o m s 100 SERIES Patio Door Sidelight and Transom Details Scale 1 1 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical Section Sidelight Vertical Section Sidelight, Stucco Exterior Horizontal Section Sidelight/Transom, Stucco Exterior Horizontal Section Sidelight/Transom Vertical Section Transom Vertical Section Transom, Stucco Exterior 4" (1 0 2 ) Si d e l i g h t D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g 1 3 ⁄8" (35) 5 1 ⁄8" (130) 4 1 ⁄ 8" (1 0 5 ) 1 ⁄ 2" (1 3 ) Un o b s t r u c t e d G l a s s Low-E Glass sill head 5 3 ⁄16" (132) 2 1 ⁄4" (57) 1 3 ⁄4" (44) 1 7⁄8" (48) 4" (1 0 2 ) Si d e l i g h t D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g 4 1 ⁄8" (1 0 5 ) 1 ⁄ 2" (1 3 ) Un o b s t r u c t e d G l a s s 1 ⁄ 8" (3 ) 1" (25) 5 1 ⁄8" (130) 5 3 ⁄16" (132) Low-E Glass head sill head 1 7⁄8" (48) 2 1 ⁄4" (57) 1 3 ⁄4" (44) 4" (1 0 2 ) Tr a n s o m D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1 3 ⁄8" (35) 5 1 ⁄8" (130) 3 ⁄ 8" (1 0 ) 4" (1 0 2 ) 3 ⁄ 8" (1 0 ) Low-E Glass sill head 1 7⁄8" (48) 1 3 ⁄4" (44) 4" (1 0 2 ) Tr a n s o m D i m e n s i o n H e i g h t Mi n i m u m R o u g h O p e n i n g Un o b s t r . Gl a s s 1" (25) 5 1 ⁄8" (130) 3 ⁄ 8" (1 0 ) 4" (1 0 2 ) 3 ⁄ 8" (1 0 ) 1 ⁄ 8" (3 ) 1 ⁄ 8" (3 ) Low-E Glass sill head 1 7⁄8" (48) 1 3 ⁄4" (44) (102)(102) Window Dimension Width Minimum Rough Opening 4"Unobstr. Glass 4" 3 ⁄8" (10) 1 ⁄8" (3)1 ⁄8" (3) 3 ⁄8" (10) 1" (2 5 ) 5 1 ⁄ 8" (1 3 0 ) jambjamb 1 3 ⁄4" (44) (102)(102) Window Dimension Width Minimum Rough Opening 4"Unobstr. Glass1 3 ⁄8" (3 5 ) 5 1 ⁄ 8" (1 3 0 ) 3 ⁄8" (10) 3 ⁄8" (10) 4"jambjamb 1 3 ⁄4" (44) See page 105 for joining details. • Light-colored areas are parts included with sidelight/transom. Dark-colored areas are additional Andersen® parts required to complete sidelight/transom assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Drip cap is required to complete door installation as shown but may not be included with door. Use of drip cap is recommended for proper installation. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. 1 3/8" F l a n g e S e t b a c k 1" F l a n g e S e t b a c k W i t h S t u c c o K e y 104 PATIO DOOR SIDELIGHTS & TRANSOMS • Light-colored areas are parts included with door/sidelight/transom. Dark-colored areas are additional Andersen® parts required to complete door/sidelight/transom assembly as shown. • Minimum rough openings may need to be increased to allow for use of building wraps, flashing, sill panning, brackets, fasteners or other items. See installation information on page 121. • Details are for illustration only and are not intended to represent product installation methods or materials. Refer to product installation instructions at andersenwindows.com. • Structural performance of any combination is only as high as the lowest structural performance of any individual product or join in the combination. • Contact your Andersen supplier for information on meeting wind load requirements for patio door joined combinations. • Dimensions in parentheses are in millimeters. For more information on joining, refer to the Combination Designs section starting on page 107. Transom Over SidelightTransom Over Gliding Patio Door Overall Transom/Door or Transom/Sidelight Dimension Height – Sum of individual transom/door or transom/sidelight heights plus 3/4" (19). Overall Minimum Rough Opening Height – Overall dimension height plus 1/2" (13). Horizontal (stack) Easy Connect Fiberglass Joining Details Scale 11 ⁄2" (38) = 1'-0" (305) — 1:8 Vertical (ribbon) Easy Connect Fiberglass Joining Details Scale 11 ⁄2" (38) = 1'-0" (305) — 1:8 Sidelight to SidelightSidelight to Gliding Patio Door Operating Jamb Sidelight to Gliding Patio Door Stationary Jamb Overall Door-Sidelight or Sidelight-Sidelight Dimension Width – Sum of individual door-sidelight or sidelight-sidelight widths plus 3/4" (19). Overall Minimum Rough Opening Width – Overall dimension width plus 3/4" (19). (2 2 2 ) 8 3 ⁄4" 3 ⁄4" (1 9 ) (2 2 2 ) 8 3 ⁄4" 3 ⁄4" (19) (222) 8 3 ⁄4" 3 ⁄4" (19) (222) 8 3 ⁄4" 3 ⁄4" (19) (222) 8 3 ⁄4" Sidelight to Gliding Patio Door to Sidelight Stationary Jamb, Operating Jamb Overall Sidelight-Door-Sidelight Dimension Width – Sum of individual sidelight-door-sidelight widths plus 1 1/2" (38). Overall Minimum Rough Opening Width – Overall dimension width plus 3/4" (19). 3 ⁄4" (19) (222) 8 3 ⁄4" 3 ⁄4" (19) (222) 8 3 ⁄4" The addition of joining materials will affect the overall rough opening dimension. The addition of joining materials will affect the overall rough opening dimension. 105 10 0 S e r i e s P a t i o D o o r Jo i n i n g D e t a i l s 100 SERIES Unobst. Glass Single-Panel Width = (door width ÷ 2) - 5.500" (140) Two-Panel Width = door width - 11.000" (279) Height = door height - 8.250" (210) Minimum R.O.Width = door width + 3/4" (19) Height = door height + 1/2" (13) Clear Opening Width = (door width ÷ 2) - 6.125" (156) Height = door height - 3.625" (92) CUSTOM WIDTHS CU S T O M H E I G H T S 14 1 ⁄4" (362) 47 1 ⁄4" (1200)to 79 1 ⁄ 2" (2 0 1 9 ) 95 1 ⁄ 2" (2 4 2 6 ) to CUSTOM WIDTHS CU S T O M H E I G H T S 59 1 ⁄4" (1505) 95 1 ⁄4" (2419)to 79 1 ⁄ 2" (2 0 1 9 ) 95 1 ⁄2" (2 4 2 6 ) to Unobst. Glass Width = sidelight width - 8.048" (204) Height = sidelight height - 8.048" (204) Minimum R.O.Width = sidelight width + 3/4" (19) Height = sidelight height + 1/2" (13) Unobst. Glass Width = transom width - 8.048" (204) Height = transom height - 8.048" (204) Minimum R.O.Width = transom width + 3/4" (19) Height = transom height + 3/4" (19) Gliding Patio Doors Patio Door Sidelights Patio Door Transoms CUSTOM WIDTHS CU S T O M H E I G H T S 14 1 ⁄4" (362) 95 1 ⁄4" (2419)to 14 1 ⁄ 4" (3 6 2 ) 23 1 ⁄ 4" (5 9 1 ) to Custom Sizes and Specification Formulas 100 Series custom-size patio doors and patio door sidelights and transoms are available in 1 ⁄8" (3) increments between minimum and maximum widths and heights shown. Some restrictions apply. To meet or exceed a clear opening width of 32" (813), select a custom-size door width that requires a rough opening width of 6'-6" (1981) or greater. • Clear Opening formulas provide dimensions for determining area available for egress. Minimum R.O. (minimum rough opening) formulas provide minimum rough opening width and height dimensions. Unobst. Glass (unobstructed glass) formulas provide dimensions for determining area available for passage of light. • Dimensions in parentheses are in millimeters. 106 PATIO DOOR CUSTOM SIZES 107 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES Combination Types Ribbons are horizontal window combinations (vertical joins) where opposite ends (head and sill) of individual windows are fastened to the building structure. Stacks are vertical window combinations (horizontal joins) where opposite sides (both side jambs) of individual windows are fastened to the building structure. One-way configurations or two-way configurations are used in combination designs. Stack CombinationRibbon Combination One-Way Two-way combinations exist when multiple vertical stacks and horizontal ribbons are joined together. Unlike one-way combinations, the adjacent sides (head and sill, or both side jambs) of individual units are not necessarily fastened directly to the building structure. Two-way combinations are joined with both vertical and horizontal joining material, and may require reinforced joining materials and brackets depending on the local building code requirement for design wind load (measured in pounds per square foot, psf). Two-Way Determining Design Wind Load Performance Proper combination design in conformance with local wind load requirements is vital to the success of your project. To make sure a combination is safe and that it complies with local building codes, the combination design wind load performance capacity must be determined. Correctly determining this performance capacity involves the following three steps: STEP 2: Determine Product Performance Compare product Design Pressure Rating data to the local building code (psf) requirement. This will show whether the individual units in a com bi na tion design are acceptable. STEP 3: Determine Combination Performance This step helps determine whether a given product, size, configuration and joining material type will meet the local building code design wind load requirement. To determine what joining material type to use (non-reinforced or reinforced), compare the local building code design wind load requirement to the design wind load table value for a particular joining material on the following pages. STEP 1: Determine Building Code Requirement Make sure you have the proper local codes and have identified specified compliance values. This calculated value (psf) will be used to determine if the combination will be ac cept able (STEP 3). Multiple Ribbon/Stack Combination Andersen® window and patio doors make it easy to create a wide variety of combination designs Andersen Joining Material For a successful installation, one engineered to provide the required design pressure, it is important Andersen joining materials and installation accessories be specified by a project architect or contractor. For one- and two-way combinations, Andersen offers a fiberglass joining system that meets specified performance requirements and enhances the look of Andersen products without sacrificing performance. The addition of joining materials will affect the overall rough opening dimension. See page 121. For all joining methods, read and follow product joining and installation instructions in their entirety. Visit andersenwindows.com for instructions. Exterior trim strips and trim strip end caps are included with each kit for finishing the exterior join. Interior trim is included with each joining kit for finishing the join on the interior. Components used with each joining system will vary depending on products being joined. Check with your Andersen supplier for more information. Reinforced joining material is used to create product alignment, positive joining and load transfer between Andersen windows and doors and the rough opening. They provide added strength capable of withstanding a greater range of wind load pressures. Non- reinforced joining material is used to create alignment and positive joining between windows. Joining materials are not connected to the rough opening structure. The structural performance of any combination is only as high as the lowest structural performance rating of any individual unit or joining material in the combination. Contact your Andersen supplier for specific performance and product recommendations. 108 COMBINATION DESIGNS psf(A + B) ÷ 2 = 4'-0" (1219)50 50 49 43 39 34 30 (A + B) ÷ 2 = 3'-6" (1067)50 50 50 47 42 38 33 (A + B) ÷ 2 = 3'-0" (914)50 50 50 50 47 43 38 (A + B) ÷ 2 = 2'-6" (762)50 50 50 50 50 50 45 (A + B) ÷ 2 = 2'-0" (610)50 50 50 50 50 50 50 C = (length of join)5'-0" (1524) 5'-6" (1676) 6'-0" (1829) 6'-6" (1981) 7'-0" (2134) 7'-6" (2286) 8'-0" (2438) psf(A + B) ÷ 2 = 5'-0" (1524)50 50 45 39 35 31 28 (A + B) ÷ 2 = 4'-6" (1372)50 50 46 41 36 33 30 (A + B) ÷ 2 = 4'-0" (1219)50 50 49 43 39 35 32 (A + B) ÷ 2 = 3'-6" (1067)50 50 50 47 42 39 36 (A + B) ÷ 2 = 3'-0" (914)50 50 50 50 47 43 40 (A + B) ÷ 2 = 2'-6" (762)50 50 50 50 50 50 46 (A + B) ÷ 2 = 2'-0" (610)50 50 50 50 50 50 50 C = (length of join)5'-0" (1524) 5'-6" (1676) 6'-0" (1829) 6'-6" (1981) 7'-0" (2134) 7'-6" (2286) 8'-0" (2438) psf (A + B) ÷ 2 = 6'-0" (1829)50 50 43 37 32 29 26 (A + B) ÷ 2 = 5'-6" (1676)50 50 44 38 33 30 27 (A + B) ÷ 2 = 5'-0" (1524)50 50 45 39 35 31 28 (A + B) ÷ 2 = 4'-6" (1372)50 50 46 41 36 33 30 (A + B) ÷ 2 = 4'-0" (1219)50 50 49 43 39 35 32 (A + B) ÷ 2 = 3'-6" (1067)50 50 50 47 42 39 36 (A + B) ÷ 2 = 3'-0" (914)50 50 50 50 47 43 40 (A + B) ÷ 2 = 2'-6" (762)50 50 50 50 50 50 46 (A + B) ÷ 2 = 2'-0" (610)50 50 50 50 50 50 50 C = (length of join)5'-0" (1524) 5'-6" (1676) 6'-0" (1829) 6'-6" (1981) 7'-0" (2134) 7'-6" (2286) 8'-0" (2438) 1-Way Non-Reinforced Fiberglass Joining 100 Series Windows: Picture to Picture, Casement to Casement, Awning to Awning, Casement to Picture, Awning to Picture Applicable for flanged or flangeless installations into wood or metal. Ratings for windows installed into concrete or masonry are lower. Av e r a g e A d j a c e n t W i n d o w D i m e n s i o n Av g . A d j . W i n d o w D i m . 1-Way Non-Reinforced Fiberglass Joining 100 Series Windows: Single-Hung to Picture, Gliding to Picture Applicable for flanged or flangeless installations into wood or metal. Ratings for windows installed into concrete or masonry are lower. Av g . A d j a c e n t W i n d o w D i m . 1-Way Non-Reinforced Fiberglass Joining 100 Series Windows: Single-Hung to Single-Hung, Gliding to Gliding, Single-Hung to Casement, Single-Hung to Awning Applicable for flanged or flangeless installations into wood or metal. Ratings for windows installed into concrete or masonry are lower. BA C BA C BA C 1/2" (13) x 3 1/4" (83) Fiberglass Joining Material 1/2" (13) x 3 1/4" (83) Fiberglass Joining Material 1/2" (13) x 3 1/4" (83) Fiberglass Joining Material • Numerical values in charts represent structural pressure only. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Easy Connect and other fiberglass joins are certified up to PG50 when installed according to Andersen installation instructions. • Andersen® products must be installed and anchored properly according to joining and installation instructions to meet rated structural performance. Refer to product joining and installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. • Contact your Andersen supplier for joining windows to patio doors and for specific performance and product recommendations. • Transom windows use picture frame type. Integral transom windows use single-hung frame type. Combination performance should be determined accordingly. 109 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES psf (A + B) ÷ 2 = 8'-0" (2438)50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 7'-6" (2286)50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 7'-0" (2134)50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 6'-6" (1981)50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 6'-0" (1829)50 50 50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 5'-6" (1676)50 50 50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 5'-0" (1524)50 50 50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 4'-6" (1372)50 50 50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 4'-0" (1219)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 37 35 28 27 (A + B) ÷ 2 = 3'-9" (1372)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 42 40 30 28 (A + B) ÷ 2 = 3'-6" (1067)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 44 42 32 30 (A + B) ÷ 2 = 3'-0" (914)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 48 36 34 (A + B) ÷ 2 = 2'-6" (762)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 42 40 (A + B) ÷ 2 = 2'-0" (610)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 1'-6" (457)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 C = (length of join)2'-0" (610) 2'-6" (762) 3'-0" (914) 3'-6" (1067) 4'-0" (1219) 4'-6" (1372) 5'-0" (1524) 5'-6" (1676) 6'-0" (1829) 6'-6" (1981) 7'-0" (2134) 7'-6" (2286) 8'-0" (2438) 8'-6" (2591) 9'-0" (2743) 9'-6" (2896) 10'-0" (3048) 10'-6" (3200) 11'-0" (3353) 11'-6" (3505) 12'-0" (3658) 1-Way Reinforced Easy Connect Fiberglass Joining 100 Series Windows: Casement, Awning, Single-Hung, Gliding, Picture Applicable for flanged or flangeless installations into wood, metal, concrete or masonry. Av e r a g e A d j a c e n t W i n d o w D i m e n s i o n psf (A + B) ÷ 2 = 6'-0" (1829)50 50 50 50 50 50 50 50 50 50 50 50 50 50 49 44 40 26 23 21 20 (A + B) ÷ 2 = 5'-6" (1676)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 48 43 28 26 23 21 (A + B) ÷ 2 = 5'-0" (1524)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 48 32 30 26 24 (A + B) ÷ 2 = 4'-6" (1372)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 36 33 27 25 (A + B) ÷ 2 = 4'-0" (1219)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 41 37 30 28 (A + B) ÷ 2 = 3'-9" (1372)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 43 40 32 30 (A + B) ÷ 2 = 3'-6" (1067)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 47 42 35 32 (A + B) ÷ 2 = 3'-0" (914)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 40 37 (A + B) ÷ 2 = 2'-6" (762)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 43 40 (A + B) ÷ 2 = 2'-0" (610)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 (A + B) ÷ 2 = 1'-6" (457)50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 C = (length of join)2'-0" (610) 2'-6" (762) 3'-0" (914) 3'-6" (1067) 4'-0" (1219) 4'-6" (1372) 5'-0" (1524) 5'-6" (1676) 6'-0" (1829) 6'-6" (1981) 7'-0" (2134) 7'-6" (2286) 8'-0" (2438) 8'-6" (2591) 9'-0" (2743) 9'-6" (2896) 10'-0" (3048) 10'-6" (3200) 11'-0" (3353) 11'-6" (3505) 12'-0" (3658) 2-Way Reinforced Easy Connect Fiberglass Joining* 100 Series Windows: Casement, Awning, Single-Hung, Gliding, Picture Applicable for flanged or flangeless installations into wood, metal, concrete or masonry. Av e r a g e A d j a c e n t W i n d o w D i m e n s i o n C BA CB A A B C A B C 3/4" (19) x 5 1/8" (130) Fiberglass Joining Material For wall depths ≥ 4 9/16" (116). Red lines represent reinforced joins. Blue lines represent non-reinforced joins. 3/4" (19) x 5 1/8" (130) Fiberglass Joining Material For wall depths ≥ 4 9/16" (116). • Numerical values in charts represent structural pressure only. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Easy Connect and other fiberglass joins are certified up to PG50 when installed according to Andersen installation instructions. • Andersen® products must be installed and anchored properly according to joining and installation instructions to meet rated structural performance. Refer to product joining and installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. • Contact your Andersen supplier for joining windows to patio doors and for specific performance and product recommendations. • Transom windows use picture frame type. Integral transom windows use single-hung frame type. Combination performance should be determined accordingly. • Performance of two-way combinations may be limited by non-reinforced joins 6' (1829) or greater in length. Verify performance of non-reinforced joins within two-way combinations using the appropriate non-reinforced joining table. *All two-way joining requires both non-reinforced and reinforced elements. Intersecting reinforced or non-reinforced joins are not available. 110 COMBINATION DESIGNS psf (A + B) ÷ 2 = 8'-0" (2438)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 7'-6" (2286)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 7'-0" (2134)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 6'-6" (1981)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 6'-0" (1829)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 5'-6" (1676)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 5'-0" (1524)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 4'-6" (1372)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 4'-0" (1219)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 3'-9" (1372)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 3'-6" (1067)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 3'-0" (914)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 2'-6" (762)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 2'-0" (610)30 30 30 30 30 30 30 30 30 30 30 30 30 (A + B) ÷ 2 = 1'-6" (457)30 30 30 30 30 30 30 30 30 30 30 30 30 C = (length of join)2'-0" (610) 2'-6" (762) 3'-0" (914) 3'-6" (1067) 4'-0" (1219) 4'-6" (1372) 5'-0" (1524) 5'-6" (1676) 6'-0" (1829) 6'-6" (1981) 7'-0" (2134) 7'-6" (2286) 8'-0" (2438) Av e r a g e A d j a c e n t D o o r / S i d e l i g h t / T r a n s o m D i m e n s i o n 3/4" (19) x 5 1/8" (130) Fiberglass Joining Material 8' M a x . (2 4 3 8 ) BA C BA C C B A BA C C B A 1-Way Reinforced Easy Connect Fiberglass Joining 100 Series Patio Doors: Gliding Patio Doors, Patio Door Sidelights and Transoms Applicable for field joining kits only. • Numerical values in charts represent structural pressure only. • Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. • Easy Connect and other fiberglass joins are certified up to PG50 when installed according to Andersen installation instructions. • Andersen® products must be installed and anchored properly according to joining and installation instructions to meet rated structural performance. Refer to product joining and installation instructions at andersenwindows.com. • Dimensions in parentheses are in millimeters. • Contact your Andersen supplier for joining windows to patio doors and for specific performance and product recommendations. 111 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES Andersen® Product 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 100 Series Casement Windows 1620 1650 2020 2050 2660 2626 2656 3056 3030 1626 1656 2026 2056 2630 3026 3060 3036 1630 1660 2030 2060 2636 3040 1636 2036 2620 2640 3046 1640 2040 3020 2646 3050 1646 2046 2650 100 Series Awning Windows 1616 2016 4016 2020 3020 2626 4026 3030 1620 2616 2026 3620 2630 3630 1626 3016 2030 4020 3026 4030 1630 3616 2620 3626 100 Series Single-Hung Windows 1620 1626 1666 3030 2036 2076 2640 2646 3646 3050 3056 3660 2020 1630 1670 3626 2040 2636 3040 2650 4046 3650 3060 3666 2620 1636 1676 3630 2046 3036 3640 2656 4050 3066 3670 3020 1640 2026 4026 2050 3636 4040 2660 3070 3676 3620 1646 2030 4030 2056 4036 2666 3076 4060 4020 1650 2626 2060 2670 3656 4066 1656 2630 2066 2676 4056 4070 1660 3026 2070 3046 4076 100 Series Gliding Windows Active-Stationary or Stationary-Active 2010 2056 4016 2620 3020 3620 3626 4626 4030 4630 5630 5036 5636 6040 2016 2060 4610 2626 3026 4020 3630 5026 4036 4636 6030 5040 5640 6046 2020 2610 4616 2630 3030 4620 3636 5626 4040 4640 5046 5646 2026 2616 5010 2636 3036 5020 3640 6026 4046 4646 5050 5650 2030 3010 5016 2640 3040 5620 3646 4050 4650 5056 6036 2036 3016 5610 2646 3046 6020 3650 4056 4656 5656 6050 2040 3610 5616 2650 3050 3656 4060 4660 5660 6056 2046 3616 6010 2656 3056 3660 5030 6060 2050 4010 6016 2660 3060 4026 5060 100 Series Gliding Windows Active-Stationary-Active 5016 6020 6036 8020 7040 8040 7640 8636 8646 9050 12056 10056 5020 6026 6040 8620 7046 7646 8640 8650 9056 12060 11060 5026 6030 6046 9020 7050 7650 9026 8656 9060 12036 5030 7016 6050 10020 7056 7656 9030 8660 10060 12040 5036 7616 6056 11020 7060 7660 9036 10030 11030 12046 5040 8016 6060 12020 7626 8046 9040 10036 11036 5046 8616 7020 7630 8050 9046 10040 11040 5050 9016 7026 7636 8056 10026 10046 11046 5056 10016 7030 8026 8060 11026 10050 11050 5060 11016 7036 8030 8626 12026 11056 12030 6016 12016 7620 8036 8630 12050 100 Series Picture, Transom and Specialty Windows 1010 5610 1616 2060 7016 2626 3030 3636 4040 5066 6646 1016 6010 1620 2066 7020 2630 3036 3640 4046 5070 6650 1020 6610 1626 2070 7616 2636 3040 3646 4050 5076 6656 1026 7010 1630 2076 7620 2640 3046 3650 4056 5080 6660 1030 7610 1636 2080 8016 2646 3050 3656 4060 5640 7040 1036 8010 1640 2616 8020 2650 3056 3660 4066 5646 7046 1040 1646 2620 2656 3060 3666 4070 5650 7050 1046 1650 3016 2660 3066 3670 4076 5656 7056 1050 1656 3020 2666 3070 3676 4080 5660 7060 1056 1660 3616 2670 3076 3680 4640 5666 7640 1060 1666 3620 2676 3080 4036 4646 5670 7646 1066 1670 4016 2680 3630 4636 4650 5676 7650 1070 1676 4020 3026 4030 5036 4656 5680 7656 1076 1680 4616 3626 4630 5636 4660 6040 7660 1080 2016 4620 4026 5030 6036 4666 6046 8040 1610 2020 5016 4626 5630 6636 4670 6050 8046 2010 2026 5020 5026 6030 7036 4676 6055 8050 2610 2030 5616 5626 6630 7636 4680 6060 8056 3010 2036 5620 6026 7030 8036 5040 6066 8060 3610 2040 6016 6626 7630 5046 6070 4010 2046 6020 7026 8030 5050 6076 4610 2050 6616 7626 5056 6080 5010 2056 6620 8026 5060 6640 100 Series Gliding Patio Doors 5068 6068 8068 50611 60611 80611 5080 6080 8080 100 Series Patio Door Sidelights 1368 1668 2068 2668 3068 4068 13611 16611 20611 26611 30611 40611 1380 1680 2080 2680 3080 4080 100 Series Patio Door Transoms 1313 2016 5013 2020 1316 2613 5016 2620 1320 2616 6013 3020 1613 3013 6016 4020 1616 3016 8013 5020 1620 4013 8016 6020 2013 4016 8020 • Deflection of glass will occur on units with larger glass areas. If interior/exterior grilles are used on single-hung windows, gliding windows or gliding patio doors at higher altitudes without cappillary breather tubes, some interference may occur, affecting operation. • Altitude limits for patio doors shown in two-panel configurations. These limits also qualify for same-size panels used in single-panel configurations. • Contact your Andersen supplier for altitude limits for custom-sized windows and doors. Altitude Limits The chart below gives the altitude limit in feet for 100 Series products in this guide. If the installation of a given product is at an altitude greater than that shown in this chart, a capillary breather tube must be ordered. Be aware that the use of a capillary breather tube eliminates argon gas blend fill and will result in a slightly lower thermal performance (approximately 0.02 increase in window U-Factor). For NFRC certified total unit performance on units with capillary breather tubes for higher altitude applications, see your Andersen supplier. The use of dual-pane insulating glass without capillary breather tubes at altitudes higher than its rating will result in severe glass distortion, increased glass breakage potential and a risk of seal failure. Smaller windows are most affected by altitude changes. An increase in altitude results in a decrease in atmospheric pressure. A sealed insulating glass unit attempts to combat this change by increasing its volume to reduce its pressure. One way to increase its volume is by glass deflection. A smaller window is stiffer and does not deflect as much as a larger window; therefore, it cannot relieve the pressure as readily. Thus, the load applied to the glass is greater, resulting in a greater risk for breakage. Another way the window tries to increase its volume is by increasing the edge area; i.e., the seal area. The increased pressure applied to the edge seal load for a smaller window is therefore greater, increasing the chance for seal failure. 112 PRODUCT PERFORMANCE HALLMARK CERTIFICATION The Window and Door Manufacturers Association (WDMA)-sponsored Hallmark Certification Program provides manufacturers with certification to the AAMA/WDMA/CSA 101/I.S.2/A440 Standard and is designed to provide builders, architects, specifiers and consumers with an easily recognizable means of identifying products that have been manufactured and tested in accordance with NAFS (AAMA/WDMA/CSA 101/I.S.2/A440) industry standards and other applicable performance standards. Conformance is determined by periodic in-plant inspections by a third-party administrator. Inspections include auditing licensee quality control procedures and processes, and a review to confirm products are manufactured in accordance with the appropriate performance standards. Periodic testing of representative product constructions and components by an independent testing laboratory is also required. When all of the program requirements are met, the licensee is authorized to use the WDMA Hallmark registered logo on their certification label as a means of identifying products and their performance ratings. Products successfully obtaining Hallmark Certification will be labeled with a three-part code, which includes performance class, performance grade and size tested. In addition to this mandatory requirement, you are allowed to list the design pressure on a separate line. (1) – Performance Class (2) – Performance Grade (3) – Size Tested (4) – Design Pressure In the example above, the performance class is LC, the performance grade (PG) is 40 pounds per square foot (psf) and the size tested is 71.5" x 71.5". What this means to the specifier is, based on the performance grade chart, the laboratory-tested air infiltration was less than 0.3 cfm/ft2 (test pressure is always 1.57 psf and the allowable airflow is 0.3 cfm/ft2), the product tested successfully resisted a laboratory water penetration test at a test pressure of 6.0 psf, the product tested successfully withstood a laboratory positive test pressure of 60 psf and a laboratory negative test pressure of 67 psf, and the product tested passed the laboratory requirements for operational force and forced-entry resistance. Based on this test, all products of the same design that are smaller than the tested size can be labeled with this product performance rating. IMPORTANT Building codes prescribe design pressure based on a variety of criteria (i.e., windspeed zone, building height, building type, job site exposure, etc.). Design pressures derived from Performance Grade (PG) test requirements should be used to determine compliance to building code required design pressures. Structural test pressures, which are tested at 1.5 times the design pressure, should not be used for determining design pressure code compliance. In the example above, a PG 40 performance grade rating, which passes a 40 psf design pressure, should be used for determining code compliance, not the structural test pressure of 60 psf. If you need further details about how Andersen® products perform to this standard, contact your Andersen supplier. If you need further information about the AAMA/WDMA/CSA 101/I.S.2/A440 standard or the Hallmark Certification Program, please contact: WDMA, 2001 K Street NW, 3rd Floor North, Washington, D.C. 20006. Phone: 202-367-1157 Website: wdma.com Where designated, Andersen products are tested, certified and labeled to the requirements of the Hallmark Certification Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. Hallmark Certified www.wdma.com Andersen Corporation 100 SERIES CASEMENT WINDOW Manufacturer stipulates certification as indicated below. Class LC(1) – PG40(2) – Size Tested 71.5 x 71.5 in.(3) DP+40/-45(4) Class LC(1) – PG40(2) – Size Tested 71.5 x 71.5 in.(3) DP+40/-45(4) STANDARD RATING AAMA/WDMA/CSA 101/I.S.2/A440-11 AAMA/WDMA/CSA 101/I.S.2/A440-08 PERFORMANCE STANDARDS The Window and Door Manufacturers Association (WDMA), the American Architectural Manufacturers Association (AAMA) and the Canadian Standards Association (CSA) jointly release the North American Fenestration Standard/Specification for Windows, Doors and Skylights (NAFS). NAFS is also referred to as AAMA/WDMA/CSA 101/I.S.2/A440, which is how the International Code Council (ICC) lists this standard in the International Residential Code (IRC) and International Building Code (IBC) as the means to indicate the window, door or skylights design pressure rating used to determine compliance to the job site design pressure requirements. A product only achieves a “Performance Grade” or “PG” rating when it complies with all of the NAFS performance requirements such as ease of operation, air infiltration resistance, resistance to water penetration and resistance to forced entry, etc. A “Design Pressure Rating” or “DP” rating only depicts the design and structural load performance. Performance Classes The NAFS Standard/Specification defines requirements for four performance classes. Performance classes are designated R, LC, CW and AW. This classification system provides for several levels of performance. Product selection is always based on the performance and building code requirements of the particular project. Performance Class/ Performance Grade Air Infiltration Test Pressure Maximum Allowable Air Infiltration/ Exfiltration Rate Water Penetration Resistance Test Pressure Design Pressure Structural Test Pressure R LC Pa psf L/s·m 2 cfm/ft2 Pa psf Pa psf Pa psf 15 - 75 1.57 1.5 0.30 140 2.92 720 15.04 1080 22.56 20 - 75 1.57 1.5 0.30 150 3.13 960 20.05 1440 30.08 25 25 75 1.57 1.5 0.30 180 3.76 1200 25.06 1800 37.59 30 30 75 1.57 1.5 0.30 220 4.59 1440 30.08 2160 45.11 35 35 75 1.57 1.5 0.30 260 5.43 1680 35.09 2520 52.63 40 40 75 1.57 1.5 0.30 290 6.06 1920 40.10 2880 60.15 45 45 75 1.57 1.5 0.30 330 6.89 2160 45.11 3240 67.67 50 50 75 1.57 1.5 0.30 360 7.52 2400 50.13 3600 75.19 55 55 75 1.57 1.5 0.30 400 8.35 2640 55.14 3960 82.71 60 60 75 1.57 1.5 0.30 440 9.19 2880 60.15 4320 90.23 65 65 75 1.57 1.5 0.30 470 9.82 3120 65.16 4680 97.74 70 70 75 1.57 1.5 0.30 510 10.65 3360 70.18 5040 105.26 75 75 75 1.57 1.5 0.30 540 11.28 3600 75.19 5400 112.78 80 80 75 1.57 1.5 0.30 580 12.11 3840 80.20 5760 120.30 85 85 75 1.57 1.5 0.30 620 12.94 4080 85.21 6120 127.82 90 90 75 1.57 1.5 0.30 660 13.78 4320 90.23 6480 135.34 95 95 75 1.57 1.5 0.30 682 14.25 4560 95.24 6840 142.86 100 100 75 1.57 1.5 0.30 718 15.00 4800 100.25 7200 150.38 Elements of Performance Grade (PG) Designations In order to qualify for a given performance grade (PG), test specimens need to pass all required performance tests for the following, in addition to all required auxiliary (durability) and applicable material/component tests (not shown here) for the applicable product type and desired performance class: (a) Operating force (if applicable): Maximum operating force varies by product type and performance class. (b) Air leakage resistance: Tested in accordance with ASTM E283 at a test pressure of 1.57 psf. Allowable air infiltration for R, LC and CW class designations is 0.3 cubic feet per minute per square foot of frame (cfm/ft2). (c) Water penetration resistance: Tested in accordance with ASTM E547 with the specified test pressure applied per NAFS. Test consists of four cycles. Each cycle consists of five minutes with pressure applied and one minute with the pressure released, during which the water spray is continuously applied. Water spray shall be uniformly applied at a constant rate of 5 U.S. gal/ft2 • hr. (d) Uniform load deflection test: Tested in accordance with ASTM E330 for both positive and negative pressure (pressure defined by NAFS) with the load maintained for a period of 10 seconds. The test specimen shall be evaluated for deflection during each load for permanent damage after each load and for any effects on the normal operation of the specimen. Starting with the 2008 version of NAFS, design pressure (DP) will only represent the “uniform load deflection test.” (e) Uniform load structural test: Tested in accordance with ASTM E330 for both positive and negative pressure (pressure defined by NAFS) with the load maintained for a period of 10 seconds. After loads are removed, there shall be no permanent deformation in excess of 0.4% of its span and no damage to the unit, which would make it inoperable. (f) Forced-entry resistance (if applicable): Tested in accordance with ASTM F588 (windows), F476 (swinging doors) and F842 (sliding doors) at a performance level 10 rating. Performance Grades (PG) and Corresponding Test Pressures (psf) 113 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES Performance Grade and Air Infiltration Ratings Andersen® 100 Series Product AAMA/WDMA/CSA 101/I.S.2/A440 Performance Grade (PG) +/- Corresponding Design Pressure (DP) Air Infiltration CFM/FT2 Casement Windows Single and Twin (venting/stationary)Class LC-PG40 Size Tested 71.5" x 71.5"40/45 < 0.2 Single and Twin, PG Upgrade (venting/stationary)Class LC-PG50 Size Tested 71.5" x 71.5" 50/50*< 0.2 Picture With Flanking Casements Class LC-PG40 Size Tested 143.5" x 71.5" 40/40 < 0.2 Picture With Flanking Casements, PG Upgrade Class LC-PG50 Size Tested 143.5" x 65.5" 50/50*< 0.2 Awning Windows Single and Twin (venting/stationary)Class LC-PG40 Size Tested 47.5" x 95.5"40/45 < 0.2 Single and Twin, PG Upgrade (venting/stationary)Class LC-PG50 Size Tested 47.5" x 95.5" 50/50*< 0.2 Picture Over Awning Class LC-PG40 Size Tested 47.5" x 95.5"40/45 < 0.2 Picture Over Awning, PG Upgrade Class LC-PG50 Size Tested 47.5" x 95.5" 50/50*< 0.2 Single-Hung Windows Arch Single-Hung Class LC-PG30 Size Tested 41.5" x 95.0"30/30 < 0.2 Arch Single-Hung, PG Upgrade Class LC-PG50 Size Tested 41.5" x 83.0" 50/50*< 0.2 Single-Hung Class LC-PG30 Size Tested 47.5" x 77.5"30/30 < 0.2 Single-Hung, PG Upgrade Class LC-PG50 Size Tested 47.5" x 77.5" 50/50*< 0.2 Twin and Triple Single-Hung Class LC-PG30 Size Tested 143.5" x 71.5"30/30 < 0.2 Twin and Triple Single-Hung, PG Upgrade Class LC-PG50 Size Tested 143.5" x 65.5" 50/50*< 0.2 Transom Over Single-Hung Class LC-PG30 Size Tested 47.5" x 95.5"30/30 < 0.2 Transom Over Single-Hung, PG Upgrade Class LC-PG50 Size Tested 47.5" x 95.5" 50/50*< 0.2 Picture With Flanking Single-Hungs Class LC-PG30 Size Tested 143.5" x 71.5"30/30 < 0.2 Picture With Flanking Single-Hungs, PG Upgrade Class LC-PG50 Size Tested 143.5" x 59.5" 50/50*< 0.2 Gliding Windows Gliding (active-stationary or stationary-active)Class LC-PG30 Size Tested 71.5" x 71.5"30/30 < 0.2 Gliding, PG Upgrade (active-stationary or stationary-active)Class LC-PG50 Size Tested 71.5" x 59.5" 50/50*< 0.2 Picture Over Gliding (active-stationary or stationary-active)Class LC-PG30 Size Tested 59.5" x 83.5"30/30 < 0.2 Gliding (active-stationary-active)Class LC-PG30 Size Tested 143.5" x 71.5"30/30 < 0.2 Gliding, PG Upgrade (active-stationary-active)Class LC-PG50 Size Tested 101.5" x 59.5" 50/50*< 0.2 Picture Over Gliding (active-stationary-active)Class LC-PG30 Size Tested 107.5" x 83.5"30/30 < 0.2 Picture, Transom & Specialty Windows Picture, Transom and Specialty Class LC-PG40 Size Tested 95.5" x 84.3"40/40 < 0.2 Picture, Transom and Specialty, PG Upgrade Class LC-PG50 Size Tested 95.5" x 71.5" 50/50*< 0.2 Gliding Patio Doors Class LC-PG30 Size Tested 95.3" x 95.5"30/30 < 0.2 Patio Door Sidelights Class LC-PG30 Size Tested 47.3" x 95.3"30/30 < 0.2 Patio Door Transoms Class LC-PG30 Size Tested 95.3" x 23.3"30/30 < 0.2 For current performance information, please visit andersenwindows.com. • Performance Grade (PG) ratings may vary from tested performance rating for larger or smaller units of a particular type. • This data is accurate as of August 2023. Due to ongoing product changes, updated test results or new industry standards, this data may change over time. • Where designated, Andersen products are certified and labeled to the requirements of the Hallmark Certification Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. • Contact your Andersen supplier for more information. • PG upgrade ratings do not apply to windows with insert frames. • Data does not apply to windows with flush fin frames. *Available for select sizes. Contact your Andersen supplier. Performance Grade and Air Infiltration Ratings for Windows With Flush Fin Frames Andersen® 100 Series Product AAMA/WDMA/CSA 101/I.S.2/A440 Performance Grade (PG) +/- Corresponding Design Pressure (DP) Air Infiltration CFM/FT2 Casement Windows Single and Twin (venting/stationary)Class LC-PG40 Size Tested 71.5" x 71.5"40/45 < 0.2 Awning Windows Single and Twin (venting/stationary)Class LC-PG40 Size Tested 47.5" x 95.5"40/45 < 0.2 Picture Over Awning Class LC-PG40 Size Tested 47.5" x 95.5"40/45 < 0.2 Single-Hung Windows Single-Hung Class LC-PG30 Size Tested 47.5" x 89.5"30/30 < 0.2 Twin and Triple Single-Hung Class LC-PG30 Size Tested 143.5" x 71.5"30/30 < 0.2 Gliding Windows Gliding (active-stationary or stationary-active)Class LC-PG30 Size Tested 71.5" x 71.5"30/30 < 0.2 Gliding (active-stationary-active)Class LC-PG30 Size Tested 143.5" x 71.5"30/30 < 0.2 Picture, Transom & Specialty Windows Class LC-PG40 Size Tested 95.5" x 84.3"40/40 < 0.2 For current performance information, please visit andersenwindows.com. • Performance Grade (PG) ratings may vary from tested performance rating for larger or smaller units of a particular type. • This data is accurate as of August 2023. Due to ongoing product changes, updated test results or new industry standards, this data may change over time. • Where designated, Andersen products are certified and labeled to the requirements of the Hallmark Certification Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. • Contact your Andersen supplier for more information. • PG upgrades are not available for windows with flush fin frames. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. For windows with flush fin frame, see chart below. For sound transmission ratings, see page 114. 114 Sound Transmission Ratings For current performance information, please visit andersenwindows.com. • Sound Transmission Class (STC) and Outdoor/Indoor Transmission Class (OITC) ratings are for individual units based on independent tests and represent entire unit. • This data is accurate as of August 2023. Due to ongoing product changes, updated test results or new industry standards, this data may change over time. • Contact your Andersen supplier for more information. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. STANDARD GLASS STC UPGRADE GLASS Andersen® 100 Series Product Sound Transmission Class (STC) Outdoor/Indoor Transmission Class (OITC) Sound Transmission Class (STC) Outdoor/Indoor Transmission Class (OITC) Casement Windows Single (venting/stationary)30 25 33 28 Single, PG Upgrade (venting/stationary)30 25 33 28 Awning Windows Single (venting/stationary)---- Single, PG Upgrade (venting/stationary)---- Single-Hung Windows Arch Single-Hung 28 23 32 26 Arch Single-Hung, PG Upgrade 28 23 32 26 Single-Hung 28 23 32 26 Single-Hung, PG Upgrade 28 23 32 26 Gliding Windows Gliding (active-stationary or stationary-active)--32 27 Gliding, PG Upgrade (active-stationary or stationary-active)--32 27 Gliding (active-stationary-active)---- Gliding, PG Upgrade (active-stationary-active)---- Picture, Transom & Specialty Windows Picture and Specialty – 1 3/8" Flange Setback, 1" Flange Setback, No Flange and Insert Frames 29 24 32 27 Picture and Specialty, PG Upgrade – 1 3/8" Flange Setback, 1" Flange Setback, No Flange and Insert Frames 29 24 32 27 Picture and Specialty – Flush Fin Frame 29 24 32 27 Picture and Specialty, PG Upgrade – Flush Fin Frame 29 24 32 27 Transom ---- Transom, PG Upgrade ---- Gliding Patio Doors 28 23 29 25 Patio Door Sidelights ---- Patio Door Transoms --31 26 PRODUCT PERFORMANCE 115 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES • Based on NFRC testing/simulation conditions using Windows v7.4.6.0 and NFRC validated spectral data. 0°F outside temperature, 70°F inside temperature and a 15 mph wind. 1) Visible Transmittance (VT) measures how much light comes through the glass. The higher the value, from 0 to 1, the more daylight the glass lets in. Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. 2) Shading Coefficient (SC) defines the amount of heat gain through the glass compared to a single lite of clear 1/8" (3) glass. 3) Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass directly transmitted, as well as absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product. 4) Relative Heat Gain (RHG) is the amount of heat gain through a glazing incorporating U-Factor and Solar Heat Gain Coefficient. 5) Transmission Ultra-Violet Energy (Tuv). The transmission of short-wave energy in the 300-380 nanometer portion of the solar spectrum. The energy can cause fabric fading. 6) Transmission Damage Function (Tdw). The transmission of UV and visible light energy in the 300-600 nanometer portion of the solar spectrum. The value includes both the UV and visible light energy that can cause fabric fading. This rating has also been referred to as the Krochmann Damage Function. This rating better predicts fading potential than UV transmission alone. The lower the Damage Function rating, the less transmission of short-wave energy through the glass that can potentially cause fabric fading. Fabric type is also a key component of fading potential. 7) Percent relative humidity before condensation occurs at the center of glass, taken using center of glass temperature. 8) Inside glass surface temperatures are taken at the center of glass. • This data is accurate as of November 2023. Due to ongoing product changes, updated test results or new industry standards, this data may change over time. Contact your Andersen supplier for current performance information or upgrade options. • Contact your Andersen supplier for center of glass performance data on windows with patterned glass, tempered glass and products ordered with capillary breather tubes. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. Andersen® 100 Series Product VT1 SC 2 SHGC 3 RHG 4 Fading %RH @ center7 IGST 8Tuv5Tdw6 Low-E Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)72% 0.48 0.41 98 16% 33% 61% 56°F Picture and Specialty Windows – Flush Fin Frame 72% 0.48 0.41 98 16% 33% 61% 56°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 72% 0.47 0.41 98 16% 33% 60% 55°F Gliding Patio Doors 72% 0.47 0.41 98 16% 33% 60% 55°F Patio Door Sidelights and Transoms 72% 0.47 0.41 98 16% 33% 60% 55°F Low-E With HeatLock® Technology Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)70% 0.47 0.41 96 16% 33% 44% 47°F Picture and Specialty Windows – Flush Fin Frame 70% 0.47 0.41 96 16% 33% 44% 47°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 70% 0.47 0.40 95 16% 33% 44% 47°F Gliding Patio Doors 70% 0.47 0.40 95 16% 33% 44% 47°F Patio Door Sidelights and Transoms 70% 0.47 0.40 95 16% 33% 44% 47°F Low-E SmartSun™ Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)65% 0.31 0.27 66 5% 21% 62% 56°F Picture and Specialty Windows – Flush Fin Frame 65% 0.31 0.27 66 5% 21% 62% 56°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 65% 0.31 0.27 65 5% 21% 61% 56°F Gliding Patio Doors 65% 0.31 0.27 65 5% 21% 61% 56°F Patio Door Sidelights and Transoms 65% 0.31 0.27 65 5% 21% 61% 56°F Low-E SmartSun With HeatLock Technology Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)63% 0.31 0.27 64 5% 21% 46% 48°F Picture and Specialty Windows – Flush Fin Frame 63% 0.31 0.27 64 5% 21% 46% 48°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 63% 0.31 0.27 63 5% 21% 44% 47°F Gliding Patio Doors 63% 0.31 0.27 63 5% 21% 44% 47°F Patio Door Sidelights and Transoms 63% 0.31 0.27 63 5% 21% 44% 47°F Sun Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)40% 0.29 0.25 61 16% 24% 60% 55°F Picture and Specialty Windows – Flush Fin Frame 40% 0.29 0.25 61 16% 24% 60% 55°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 40% 0.29 0.25 60 16% 24% 59% 55°F Gliding Patio Doors 40% 0.29 0.25 60 16% 24% 59% 55°F Patio Door Sidelights and Transoms 40% 0.29 0.25 60 16% 24% 59% 55°F Low-E PassiveSun Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)79% 0.79 0.69 161 29% 42% 60% 55°F Picture and Specialty Windows – Flush Fin Frame 79% 0.79 0.69 161 29% 42% 60% 55°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 79% 0.79 0.69 161 29% 42% 59% 55°F Gliding Patio Doors 79% 0.79 0.69 161 29% 42% 59% 55°F Patio Door Sidelights and Transoms 79% 0.79 0.69 161 29% 42% 59% 55°F Low-E PassiveSun With HeatLock Technology Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)77% 0.72 0.62 146 27% 40% 42% 46°F Picture and Specialty Windows – Flush Fin Frame 77% 0.72 0.62 146 27% 40% 42% 46°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 77% 0.72 0.63 146 27% 40% 42% 46°F Gliding Patio Doors 77% 0.72 0.63 146 27% 40% 42% 46°F Patio Door Sidelights and Transoms 77% 0.72 0.63 146 27% 40%42%46°F Clear Dual-Pane Casement, Awning, Single-Hung, Gliding and Transom Windows (all frames types)82% 0.89 0.78 186 58% 61% 39% 44°F Picture and Specialty Windows – Flush Fin Frame 82% 0.89 0.78 186 58% 61% 39% 44°F Picture and Specialty Windows – 1 3/8" Flange Setback, 1" Flange Setback, No Flange, Insert Frames 82% 0.89 0.78 186 58% 61% 39% 44°F Gliding Patio Doors 82% 0.89 0.78 186 58% 61% 39% 44°F Patio Door Sidelights and Transoms 82% 0.89 0.78 186 58% 61% 39% 44°F Center of Glass Performance Data For current performance information, please visit andersenwindows.com. 116 PRODUCT PERFORMANCE 1) U-Factor defines the amount of heat loss through the total unit in BTU/hr-ft 2-°F. The lower the value, the less heat is lost through the entire product. Window values represent non-tempered glass. Use of tempered glass can increase U-Factor ratings. See andersenwindows.com/nfrc for specific performance values. Door values represent tempered glass. 2) Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass directly transmitted, as well as absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product. 3) Visible Transmittance (VT) measures how much light comes through a product (glass and frame). The higher the value, from 0 to 1, the more daylight the product lets in over the product’s total unit area. Visible light transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. • NFRC ratings are based on modeling by a third-party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements. • This data is accurate as of August 2023. Due to ongoing product changes, updated test results, or new industry standards or requirements, this data may change over time. Ratings are for sizes specified by NFRC for testing and certification. Ratings may vary depending on unit size, use of tempered glass, different grille options, glass for high altitudes, etc. • Values are for single units with given pane thickness and 3/4" (19 mm) grilles for windows and 1" (25 mm) grilles for door products. Andersen® Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC2 VT 3 100 Series Casement Windows AND-N-84 2.2 mm glass Lo w - E Without Grilles 0.28 0.28 0.48 Simulated Divided Light Grilles 0.28 0.25 0.43 Finelight™ Grilles 0.28 0.25 0.43 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.25 0.43 Lo w - E w/ H e a t L o c k ®Without Grilles 0.24 0.27 0.47 Simulated Divided Light Grilles 0.24 0.25 0.42 Finelight Grilles 0.24 0.25 0.42 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.26 0.25 0.42 Lo w - E Sm a r t S u n ™ Without Grilles 0.27 0.18 0.43 Simulated Divided Light Grilles 0.27 0.17 0.39 Finelight Grilles 0.27 0.17 0.39 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.17 0.39 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.24 0.18 0.42 Simulated Divided Light Grilles 0.24 0.16 0.38 Finelight Grilles 0.24 0.16 0.38 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.25 0.16 0.38 Lo w - E Su n Without Grilles 0.28 0.17 0.26 Simulated Divided Light Grilles 0.28 0.16 0.24 Finelight Grilles 0.28 0.16 0.24 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.16 0.24 Lo w - E Pa s s i v e S u n ® Without Grilles 0.28 0.46 0.53 Simulated Divided Light Grilles 0.28 0.42 0.47 Finelight Grilles 0.28 0.42 0.47 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.42 0.47 Cl e a r Du a l - P a n e Without Grilles 0.41 0.52 0.55 Simulated Divided Light Grilles 0.41 0.48 0.49 Finelight Grilles 0.41 0.48 0.49 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.42 0.48 0.49 100 Series Awning Windows AND-N-85 2.2 mm glass Lo w - E Without Grilles 0.28 0.28 0.48 Simulated Divided Light Grilles 0.28 0.25 0.43 Finelight™ Grilles 0.28 0.25 0.43 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.25 0.43 Lo w - E w/ H e a t L o c k ®Without Grilles 0.25 0.27 0.47 Simulated Divided Light Grilles 0.25 0.25 0.42 Finelight Grilles 0.25 0.25 0.42 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.26 0.25 0.42 Lo w - E Sm a r t S u n ™ Without Grilles 0.27 0.18 0.43 Simulated Divided Light Grilles 0.27 0.17 0.39 Finelight Grilles 0.27 0.17 0.39 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.17 0.39 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.24 0.18 0.42 Simulated Divided Light Grilles 0.24 0.16 0.38 Finelight Grilles 0.24 0.16 0.38 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.26 0.16 0.38 Lo w - E Su n Without Grilles 0.28 0.17 0.26 Simulated Divided Light Grilles 0.28 0.16 0.24 Finelight Grilles 0.28 0.16 0.24 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.16 0.24 Lo w - E Pa s s i v e S u n ® Without Grilles 0.28 0.46 0.53 Simulated Divided Light Grilles 0.28 0.42 0.47 Finelight Grilles 0.28 0.42 0.47 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.42 0.47 Cl e a r Du a l - P a n e Without Grilles 0.42 0.52 0.55 Simulated Divided Light Grilles 0.42 0.48 0.49 Finelight Grilles 0.42 0.48 0.49 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.42 0.48 0.49 Andersen® Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC2 VT 3 100 Series Single-Hung Windows AND-N-80 2.2 mm glass Lo w - E Without Grilles 0.30 0.31 0.54 Simulated Divided Light Grilles 0.30 0.28 0.48 Finelight™ Grilles 0.30 0.28 0.48 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.28 0.48 Lo w - E w/ H e a t L o c k ®Without Grilles 0.26 0.31 0.53 Simulated Divided Light Grilles 0.26 0.28 0.47 Finelight Grilles 0.26 0.28 0.47 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.28 0.47 Lo w - E Sm a r t S u n ™ Without Grilles 0.29 0.21 0.49 Simulated Divided Light Grilles 0.29 0.19 0.43 Finelight Grilles 0.29 0.19 0.43 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.19 0.43 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.25 0.20 0.48 Simulated Divided Light Grilles 0.25 0.18 0.42 Finelight Grilles 0.25 0.18 0.42 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.18 0.42 Lo w - E Su n Without Grilles 0.30 0.19 0.30 Simulated Divided Light Grilles 0.30 0.17 0.27 Finelight Grilles 0.30 0.17 0.27 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.32 0.17 0.27 Lo w - E Pa s s i v e S u n ® Without Grilles 0.31 0.52 0.60 Simulated Divided Light Grilles 0.31 0.47 0.53 Finelight Grilles 0.31 0.47 0.53 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.32 0.47 0.53 Cl e a r Du a l - P a n e Without Grilles 0.46 0.59 0.62 Simulated Divided Light Grilles 0.46 0.53 0.55 Finelight Grilles 0.46 0.53 0.55 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.47 0.53 0.55 100 Series Gliding Windows AND-N-81 2.2 mm glass Lo w - E Without Grilles 0.30 0.31 0.54 Simulated Divided Light Grilles 0.30 0.28 0.48 Finelight™ Grilles 0.30 0.28 0.48 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.28 0.48 Lo w - E w/ H e a t L o c k ®Without Grilles 0.26 0.31 0.53 Simulated Divided Light Grilles 0.26 0.28 0.47 Finelight Grilles 0.26 0.28 0.47 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.28 0.47 Lo w - E Sm a r t S u n ™ Without Grilles 0.29 0.21 0.49 Simulated Divided Light Grilles 0.29 0.19 0.43 Finelight Grilles 0.29 0.19 0.43 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.19 0.43 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.26 0.20 0.48 Simulated Divided Light Grilles 0.26 0.18 0.42 Finelight Grilles 0.26 0.18 0.42 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.18 0.42 Lo w - E Su n Without Grilles 0.30 0.19 0.30 Simulated Divided Light Grilles 0.30 0.17 0.27 Finelight Grilles 0.30 0.17 0.27 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.32 0.17 0.27 Lo w - E Pa s s i v e S u n ® Without Grilles 0.31 0.52 0.60 Simulated Divided Light Grilles 0.31 0.47 0.53 Finelight Grilles 0.31 0.47 0.53 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.32 0.47 0.53 Cl e a r Du a l - P a n e Without Grilles 0.46 0.59 0.62 Simulated Divided Light Grilles 0.46 0.53 0.55 Finelight Grilles 0.46 0.53 0.55 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.47 0.53 0.55 continued on next page NFRC Certified Total Unit Performance For current performance information, please visit andersenwindows.com. 117 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES (continued) Andersen® Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC2 VT3 100 Series Picture & Specialty Windows 1 3/8" Flange Setback, 1" Flange Setback, No Flange and Insert Frames AND-N-82 3.0 mm glass Lo w - E Without Grilles 0.27 0.32 0.56 Simulated Divided Light Grilles 0.27 0.29 0.50 Finelight™ Grilles 0.27 0.29 0.50 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.29 0.50 Lo w - E w/ H e a t L o c k ®Without Grilles 0.23 0.32 0.55 Simulated Divided Light Grilles 0.23 0.29 0.49 Finelight Grilles 0.23 0.29 0.49 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.26 0.29 0.49 Lo w - E Sm a r t S u n ™ Without Grilles 0.27 0.22 0.50 Simulated Divided Light Grilles 0.27 0.20 0.45 Finelight Grilles 0.27 0.20 0.45 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.20 0.45 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.23 0.21 0.49 Simulated Divided Light Grilles 0.23 0.19 0.44 Finelight Grilles 0.23 0.19 0.44 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.25 0.19 0.44 Lo w - E Su n Without Grilles 0.28 0.20 0.31 Simulated Divided Light Grilles 0.28 0.18 0.28 Finelight Grilles 0.28 0.18 0.28 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.30 0.18 0.28 Lo w - E Pa s s i v e S u n ® Without Grilles 0.28 0.54 0.61 Simulated Divided Light Grilles 0.28 0.48 0.55 Finelight Grilles 0.28 0.48 0.55 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.30 0.48 0.55 Cl e a r Du a l - P a n e Without Grilles 0.44 0.61 0.64 Simulated Divided Light Grilles 0.44 0.55 0.57 Finelight Grilles 0.44 0.55 0.57 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.45 0.55 0.57 100 Series Picture & Specialty Windows Flush Fin Frame AND-N-192 3.0 mm glass Lo w - E Without Grilles 0.27 0.36 0.63 Simulated Divided Light Grilles 0.27 0.33 0.56 Finelight™ Grilles 0.27 0.33 0.56 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.33 0.56 Lo w - E w/ H e a t L o c k ®Without Grilles 0.23 0.35 0.61 Simulated Divided Light Grilles 0.23 0.32 0.55 Finelight Grilles 0.23 0.32 0.55 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.25 0.32 0.55 Lo w - E Sm a r t S u n ™ Without Grilles 0.26 0.24 0.56 Simulated Divided Light Grilles 0.26 0.22 0.51 Finelight Grilles 0.26 0.22 0.51 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.28 0.22 0.51 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.22 0.23 0.55 Simulated Divided Light Grilles 0.22 0.21 0.49 Finelight Grilles 0.22 0.21 0.49 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.24 0.21 0.49 Lo w - E Su n Without Grilles 0.27 0.22 0.35 Simulated Divided Light Grilles 0.27 0.20 0.31 Finelight Grilles 0.27 0.20 0.31 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.20 0.31 Lo w - E Pa s s i v e S u n ® Without Grilles 0.28 0.60 0.69 Simulated Divided Light Grilles 0.28 0.54 0.62 Finelight Grilles 0.28 0.54 0.62 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.29 0.54 0.62 Cl e a r Du a l - P a n e Without Grilles 0.46 0.68 0.72 Simulated Divided Light Grilles 0.46 0.61 0.64 Finelight Grilles 0.46 0.61 0.64 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.47 0.61 0.64 Andersen® Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC2 VT 3 100 Series Transom Windows AND-N-83 3.0 mm glass Lo w - E Without Grilles 0.29 0.32 0.56 Simulated Divided Light Grilles 0.29 0.29 0.50 Finelight™ Grilles 0.29 0.29 0.50 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.29 0.50 Lo w - E w/ H e a t L o c k ®Without Grilles 0.25 0.32 0.55 Simulated Divided Light Grilles 0.25 0.29 0.49 Finelight Grilles 0.25 0.29 0.49 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.27 0.29 0.49 Lo w - E Sm a r t S u n ™ Without Grilles 0.28 0.22 0.50 Simulated Divided Light Grilles 0.28 0.19 0.45 Finelight Grilles 0.28 0.19 0.45 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.30 0.19 0.45 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.25 0.21 0.49 Simulated Divided Light Grilles 0.25 0.19 0.44 Finelight Grilles 0.25 0.19 0.44 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.27 0.19 0.44 Lo w - E Su n Without Grilles 0.30 0.20 0.31 Simulated Divided Light Grilles - - - Finelight Grilles 0.30 0.18 0.28 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.18 0.28 Lo w - E Pa s s i v e S u n ® Without Grilles 0.30 0.54 0.61 Simulated Divided Light Grilles 0.30 0.48 0.55 Finelight Grilles 0.30 0.48 0.55 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.31 0.48 0.55 Cl e a r Du a l - P a n e Without Grilles 0.46 0.61 0.64 Simulated Divided Light Grilles 0.46 0.54 0.57 Finelight Grilles 0.46 0.54 0.57 Finelight With Exterior Applied Grilles - - - Full Divided Light Grilles 0.47 0.54 0.57 100 Series Gliding Patio Doors AND-N-100 3.1 mm glass Lo w - E Without Grilles 0.30 0.32 0.55 Simulated Divided Light Grilles 0.30 0.25 0.42 Finelight™ Grilles 0.30 0.29 0.48 Finelight With Exterior Applied Grilles 0.30 0.25 0.42 Full Divided Light Grilles 0.35 0.25 0.42 Lo w - E w/ H e a t L o c k ®Without Grilles 0.26 0.32 0.54 Simulated Divided Light Grilles 0.26 0.25 0.41 Finelight Grilles 0.26 0.28 0.47 Finelight With Exterior Applied Grilles 0.26 0.25 0.41 Full Divided Light Grilles 0.33 0.25 0.41 Lo w - E Sm a r t S u n ™ Without Grilles 0.29 0.21 0.50 Simulated Divided Light Grilles 0.29 0.17 0.38 Finelight Grilles 0.29 0.19 0.44 Finelight With Exterior Applied Grilles 0.29 0.17 0.38 Full Divided Light Grilles 0.34 0.17 0.38 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.25 0.21 0.49 Simulated Divided Light Grilles 0.25 0.17 0.37 Finelight Grilles 0.25 0.19 0.43 Finelight With Exterior Applied Grilles 0.25 0.17 0.37 Full Divided Light Grilles 0.32 0.17 0.37 Lo w - E Su n Without Grilles 0.30 0.20 0.31 Simulated Divided Light Grilles 0.30 0.16 0.23 Finelight Grilles 0.30 0.18 0.27 Finelight With Exterior Applied Grilles 0.30 0.16 0.23 Full Divided Light Grilles 0.35 0.16 0.23 Lo w - E Pa s s i v e S u n ® Without Grilles 0.31 0.53 0.61 Simulated Divided Light Grilles 0.31 0.41 0.46 Finelight Grilles 0.31 0.47 0.53 Finelight With Exterior Applied Grilles 0.31 0.41 0.46 Full Divided Light Grilles 0.35 0.41 0.46 Cl e a r Du a l - P a n e Without Grilles 0.46 0.60 0.63 Simulated Divided Light Grilles 0.46 0.46 0.48 Finelight Grilles 0.46 0.53 0.55 Finelight With Exterior Applied Grilles 0.46 0.46 0.48 Full Divided Light Grilles 0.49 0.46 0.48 continued on next page1) U-Factor defines the amount of heat loss through the total unit in BTU/hr-ft 2-°F. The lower the value, the less heat is lost through the entire product. Window values represent non-tempered glass. Use of tempered glass can increase U-Factor ratings. See andersenwindows.com/nfrc for specific performance values. Door values represent tempered glass. 2) Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass directly transmitted, as well as absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product. 3) Visible Transmittance (VT) measures how much light comes through a product (glass and frame). The higher the value, from 0 to 1, the more daylight the product lets in over the product’s total unit area. Visible light transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. • NFRC ratings are based on modeling by a third-party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements. • This data is accurate as of August 2023. Due to ongoing product changes, updated test results, or new industry standards or requirements, this data may change over time. Ratings are for sizes specified by NFRC for testing and certification. Ratings may vary depending on unit size, use of tempered glass, different grille options, glass for high altitudes, etc. • Values are for single units with given pane thickness and 3/4" (19 mm) grilles for windows and 1" (25 mm) grilles for door products. • Windows with flush fin frame are available in select Southwestern states including Arizona, California, Nevada, New Mexico and Utah. Limited configuration availability. See your Andersen supplier for more information. NFRC Certified Total Unit Performance For current performance information, please visit andersenwindows.com. 118 PRODUCT PERFORMANCE Andersen® Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC2 VT 3 100 Series Patio Door Transoms AND-N-98 3.0 mm glass Lo w - E Without Grilles 0.32 0.25 0.43 Simulated Divided Light Grilles 0.32 0.20 0.34 Finelight™ Grilles 0.32 0.23 0.38 Finelight With Exterior Applied Grilles 0.32 0.20 0.34 Full Divided Light Grilles 0.35 0.20 0.34 Lo w - E w/ H e a t L o c k ®Without Grilles 0.29 0.25 0.42 Simulated Divided Light Grilles 0.29 0.20 0.33 Finelight Grilles 0.29 0.22 0.37 Finelight With Exterior Applied Grilles 0.29 0.20 0.33 Full Divided Light Grilles 0.33 0.20 0.33 Lo w - E Sm a r t S u n ™ Without Grilles 0.31 0.17 0.38 Simulated Divided Light Grilles 0.31 0.14 0.30 Finelight Grilles 0.31 0.15 0.34 Finelight With Exterior Applied Grilles 0.31 0.14 0.30 Full Divided Light Grilles 0.34 0.14 0.30 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.29 0.17 0.37 Simulated Divided Light Grilles 0.29 0.14 0.30 Finelight Grilles 0.29 0.15 0.33 Finelight With Exterior Applied Grilles 0.29 0.14 0.30 Full Divided Light Grilles 0.33 0.14 0.30 Lo w - E Su n Without Grilles 0.32 0.16 0.24 Simulated Divided Light Grilles 0.32 0.13 0.19 Finelight Grilles 0.32 0.14 0.21 Finelight With Exterior Applied Grilles 0.32 0.13 0.19 Full Divided Light Grilles 0.35 0.13 0.19 Lo w - E Pa s s i v e S u n ® Without Grilles 0.33 0.41 0.47 Simulated Divided Light Grilles 0.33 0.33 0.37 Finelight Grilles 0.33 0.37 0.42 Finelight With Exterior Applied Grilles 0.33 0.33 0.37 Full Divided Light Grilles 0.35 0.33 0.37 Cl e a r Du a l - P a n e Without Grilles 0.45 0.47 0.49 Simulated Divided Light Grilles 0.45 0.38 0.38 Finelight Grilles 0.45 0.42 0.43 Finelight With Exterior Applied Grilles 0.45 0.38 0.38 Full Divided Light Grilles 0.46 0.38 0.38 Andersen® Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC2 VT 3 100 Series Patio Door Sidelights AND-N-97 3.0 mm glass Lo w - E Without Grilles 0.31 0.25 0.43 Simulated Divided Light Grilles 0.31 0.21 0.34 Finelight™ Grilles 0.31 0.23 0.38 Finelight With Exterior Applied Grilles 0.31 0.21 0.34 Full Divided Light Grilles 0.34 0.21 0.34 Lo w - E w/ H e a t L o c k ®Without Grilles 0.28 0.25 0.42 Simulated Divided Light Grilles 0.28 0.20 0.33 Finelight Grilles 0.28 0.23 0.37 Finelight With Exterior Applied Grilles 0.28 0.20 0.33 Full Divided Light Grilles 0.33 0.20 0.33 Lo w - E Sm a r t S u n ™ Without Grilles 0.31 0.17 0.38 Simulated Divided Light Grilles 0.31 0.14 0.31 Finelight Grilles 0.31 0.15 0.34 Finelight With Exterior Applied Grilles 0.31 0.14 0.31 Full Divided Light Grilles 0.34 0.14 0.31 Lo w - E Sm a r t S u n w/ H e a t L o c k Without Grilles 0.28 0.17 0.38 Simulated Divided Light Grilles 0.28 0.14 0.30 Finelight Grilles 0.28 0.15 0.34 Finelight With Exterior Applied Grilles 0.28 0.14 0.30 Full Divided Light Grilles 0.32 0.14 0.30 Lo w - E Su n Without Grilles 0.32 0.16 0.24 Simulated Divided Light Grilles 0.32 0.13 0.19 Finelight Grilles 0.32 0.14 0.21 Finelight With Exterior Applied Grilles 0.32 0.13 0.19 Full Divided Light Grilles 0.35 0.13 0.19 Lo w - E Pa s s i v e S u n ® Without Grilles 0.32 0.42 0.47 Simulated Divided Light Grilles 0.32 0.34 0.37 Finelight Grilles 0.32 0.37 0.42 Finelight With Exterior Applied Grilles 0.32 0.34 0.37 Full Divided Light Grilles 0.35 0.34 0.37 Cl e a r Du a l - P a n e Without Grilles 0.44 0.47 0.49 Simulated Divided Light Grilles 0.44 0.38 0.39 Finelight Grilles 0.44 0.42 0.44 Finelight With Exterior Applied Grilles 0.44 0.38 0.39 Full Divided Light Grilles 0.45 0.38 0.39 (continued) 1) U-Factor defines the amount of heat loss through the total unit in BTU/hr-ft 2-°F. The lower the value, the less heat is lost through the entire product. Window values represent non-tempered glass. Use of tempered glass can increase U-Factor ratings. See andersenwindows.com/nfrc for specific performance values. Door values represent tempered glass. 2) Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass directly transmitted, as well as absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product. 3) Visible Transmittance (VT) measures how much light comes through a product (glass and frame). The higher the value, from 0 to 1, the more daylight the product lets in over the product’s total unit area. Visible light transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. • NFRC ratings are based on modeling by a third-party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements. • This data is accurate as of August 2023. Due to ongoing product changes, updated test results, or new industry standards or requirements, this data may change over time. Ratings are for sizes specified by NFRC for testing and certification. Ratings may vary depending on unit size, use of tempered glass, different grille options, glass for high altitudes, etc. • Values are for single units with given pane thickness and 3/4" (19 mm) grilles for windows and 1" (25 mm) grilles for door products. NFRC Certified Total Unit Performance For current performance information, please visit andersenwindows.com. 119 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES 100 Series Single Hung Window AND-N-80-02062-00001 Fibrex Composite Frame, Low-E SmartSun HeatLock with Argon Product Type: Single Hung 0.25 1.42 0.20 0.48 Licensee: 129-H-899 Andersen Corporation 100 Series Single-Hung Window Manufacturer stipulates Hallmark Certication as indicated below. STANDARD RATING Class LC-PG30 Size Tested 143.5" x 71.5"DP+30/-30 Class LC-PG30 Size Tested 143.5" x 71.5"DP+30/-30 Class LC-PG30 - 3645mm x 1816mmPositive/Negative Design Pressure (DP) = 1440 Pa/-1440 PaWater Penetration Resistance Test Pressure = 220 PaCanadian Air Infiltration/Exfiltration = A3 AAMA/WDMA/CSA 101/I.S.2/A440-11 AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA/WDMA/CSA 101/I.S.2/A440-08 A440S1-09 FL 15906 Glazing: 2.2mm AN outer/2.2mm AN inner Hallmark Certied www.wdma.com Do not remove until nal code inspection. Save label for future reference. ENERGY STAR® Certied in Highlighted Regions Certi é ENERGY STAR dans les régions en surbrillance = Certied/Certi é DO NOT REMOVE UNTIL FINAL INSPECTION/NE PAS RETIRER AVANT L’INSPECTION FINALE ER/RE 18energystar.gc.ca energystar.gov Canada U.S. / É.U. DO NOT REMOVE UNTIL FINAL INSPECTION/NE PAS RETIRER AVANT L’INSPECTION FINALE = Certified/Certifié ENERGY STAR® Certified in Highlighted Regions Certifié ENERGY STAR dans les régions en surbrillance Meets or exceeds CEC & IECC Air Infiltration Requirements of 0.2 CFM/sq.ft. or lower. WDMA Hallmark Certification Program. Complies with HUD UM Bulletin No. 111. This product can expose you to chemicals includingtitanium dioxide, which is known in the state ofCalifornia to cause cancer, and methanol, which isknown to the state of California to cause birth defectsor other reproductive harm. For more information go to www.P65Warnings.ca.gov Solar Heat Gain Coefficient measures how well a product blocks heat caused by sunlight (the lower the number, the more it will help reduce the use of air conditioning and as a result, reduce electrical bills and energy use). U-Factor indicates how well a product prevents heat from escaping (the lower the number, the better). Visible Transmittance refers to how much visible light comes through a product (the closer to 1.0, the more light is transmitted). Performance Grade (PG) and Design Pressure (DP) Ratings About the NFRC The National Fenestration Rating Council (NFRC) is a nonpartisan coalition of professionals whose purpose is to provide fair, accurate and credible energy performance ratings for fenestration products. NFRC’s membership includes manufacturers, suppliers, designers, specifiers, utility companies, government agencies and other building industry representatives. Andersen Corporation is a founding member of the NFRC and continues to support its work by providing fair, accurate and credible energy performance ratings to consumers and the building industry. If you have any questions about the NFRC, its program or energy performance ratings, write them at: NFRC, 6305 Ivy Lane, Suite 410, Greenbelt, MD 20770. Phone: 301-589-1776. Website: nfrc.org About the Label Look for this certification label on every window and patio door you buy. The NFRC section was designed by the National Fenestration Rating Council to provide accurate information that helps you promote the energy efficiency of the homes you build. These ratings allow you – and your customers – to measure and compare the energy performance of similar products. If the product does not have this label, the NFRC has not verified its claims. • NFRC ratings are based on modeling by a third-party agency as validated by an independent test lab in compliance with NFRC program and procedural requirements. • “ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. ENERGY STAR® Climate Zone Map is based on U-Factor and solar heat gain coefficient criteria for specific ENERGY STAR climate zones within the United States and Canada. The shading of the map shows which climate zone(s) a particular product and glass type is ENERGY STAR Version 7.0 certified in. Visit andersenwindows.com/energystar for more details. Glass Construction used with this product type. Energy Rating (ER) represents “Energy Rating” and is a rating used in Canada for product comparison purposes (the higher the ER number, the more energy saved during the heating season). Test Standards WDMA Hallmark Certification verifies the performance ratings of this product were tested by an independent testing laboratory and verified by a third-party certification program. Dimensions in parentheses are in millimeters. Exterior Sill Extender for Insert Windows 1" (25)-wide PVC (shown) or 2" (51)-wide Fibrex sill extender fits into an exterior accessory kerf on the insert window frame to hide the gap between the new insert window and the existing window frame at the sill. Precut to fit a 14° sill slope, it can be cut to fit other slopes or lengths as needed. Available in white, Sandtone, Terratone, dark bronze and black. Exterior Frame Extender for Insert Windows 1" (25)-wide PVC or 2" (51)-wide Fibrex (shown) frame extender fits into exterior accessory kerfs on the insert window frame to hide the gap around the sides and/or at the head between the new insert window and the existing window frame. Available in long lengths or can be ordered cut to approximate lengths for convenience at the job site. Available in white, Sandtone, Terratone, dark bronze and black. Head Expander for Insert Windows A head expander assists in filling the opening at the top of the insert window frame when doing an interior installation. Available in white, dark bronze and black. Two-tone options are available in black/white or dark bronze/white. Interior Trim for Flush Fin Windows Flat or curved interior trim for flush fin window frame provides a fast and easy way to cover existing aluminum window frames. The trim is pre- scored for easy sizing and includes a 3 ⁄4" (19) adhesive strip on the back side for secure positioning. Flat interior trim is available in 12' (3658) lengths, and curved interior trim will come cut to the size of the unit. Available in white, Sandtone, dark bronze and black. Optional accessories are available for the installation of Andersen® windows and patio doors. Keep instructions and safety information in mind when considering the installation and use of any Andersen product. For questions, contact your local Andersen supplier. Fibrex® Trim Board This solid cellular Fibrex trim board can be cut or ripped to size, and fastened using nails or screws. 3 1⁄2" (89) x 3 ⁄4" (19) thick in 10' (3048) lengths. Available in white, canvas, prairie grass, Sandtone, Terratone, cocoa bean, dark bronze, red rock, forest green, dove gray and black. Vinyl Channels Rigid vinyl “J” and “h” channels are 1⁄2" (13) deep and come in 150" (3810) lengths. “J” channels are 3 ⁄4" (19) wide and “h” channels are 1" (25) wide. “J” and “h” channels are available in white, Sandtone and Terratone. “H” channels are 3 ⁄4" (19) deep and come in 84" (2134) and 150" (3810) lengths. White “H” channels are 3 ⁄4" (19) wide. Sandtone and Terratone “H” channels are 1" (25) wide. Auxiliary Casing Made of cellular Fibrex material. 1 3 ⁄16" (30) x 1 3 ⁄16" (30) thick in 150" (3810) lengths. Available in white, canvas, Sandtone, Terratone, dark bronze, forest green and black. Drip Cap Heavy 24-gauge corrosion-resistant aluminum construction in two profiles to match frames. Available in 6' (1829), 10' (3048) and 12'-7 1⁄2" (3848) lengths in white, canvas, Sandtone, Terratone, dark bronze, forest green and black. Coil Stock Made from .018" thick aluminum, Andersen coil stock is available in 24" (610) x 50' (15240) rolls and can be ordered in white, canvas, prairie grass, Sandtone, Terratone, cocoa bean, dark bronze, red rock, forest green, dove gray and black. Color- matched 1 1⁄4" (32)-long stainless steel trim nails are also available and can be ordered in 1 lb/454 kg boxes. Coil stock can be cut and formed to profiles at the job site. For insert window frames, coil stock fits into the exterior accessory kerf in the window frame, then wraps the existing wood window trim. Shims Flat self-hanging shims help with a secure installation. Available in boxes of 248 shims. Straight Flashing Tape Superior high-tack acrylic adhesive sticks and stays adhered. Split release liner for easy and accurate application. Available in 4" (102) or 6" (152) widths in 33' (10058) or 75' (22860) lengths in a single roll or case of 12. Installation Foam Available for sealing the unit into the rough opening, our minimally expanding low-pressure build foam remains soft and pliable. Foam Backer Rod 3⁄8" (10) backer rod helps provide an air seal around the frame. Available in 100' (30480) rolls. Color-Matched Sealant This high-performance sealant provides excellent long-term durability and adhesion to Andersen product substrates and common building materials. Color-matched sealant, in white, canvas, prairie grass, Sandtone, Terratone, cocoa bean, dark bronze, red rock, forest green, dove gray and black, is available in single 10.1 ounce/300 ml tubes or in a case of 12 tubes. 20 ounce/591 ml foil packs are available in white, dark bronze and black. Installation Screws Properly sized installation screws are provided for windows that will be secured through the jamb. INSTALLATION ACCESSORIES Insert window shown with exterior frame extenders and sill extender in dark bronze. ADDITIONAL INSTALLATION ACCESSORIES FOR INSERT & FLUSH FIN WINDOWS 120 INSTALLATION ACCESSORIES Dimensions in parentheses are in millimeters. ROUGH OPENINGS The purpose of a rough opening is to allow for proper spacing between the window or patio door unit and the building structure. The space is required for locating, leveling and squaring the unit during installation and to provide an area for insulation. A rough opening that is incorrectly sized may affect unit operation and may not allow for adequate fastening of the unit to the building structure. Andersen® rough opening dimensions are provided as a guideline to help determine the minimum amount of space needed between the window or patio door and the building structure. See appropriate product sections for rough opening guidelines for each product. Keep in mind that rough opening dimensions may need to be altered from published guidelines, depending on installation methods, joining methods, replacement methods, etc. For example, flashing systems can reduce the amount of available rough opening space and should be factored in when calculating rough opening dimensions. The use of support or joining materials will encroach on the rough opening and may require additional rough opening space between the unit and the building structure, depending on the thickness of the flashing system and joining materials used. To facilitate drainage, the rough opening sill plate should never slope toward the interior. For challenging environments and other information, refer to EEBA’s (Energy and Environmental Building Association) Water Management Guide (eeba.org). IMPORTANCE OF PROPER INSTALLATION Proper installation and maintenance of Andersen products is essential to attain optimum performance and operation. Installation instructions that provide guidelines for proper installation are typically provided with Andersen products. They are also available by visiting andersenwindows.com. Remember that every installation is different, and Andersen strongly recommends consultation with the local supplier or an experienced contractor, architect or structural engineer prior to the installation of any Andersen product. The method of attachment for Andersen products, fastener selection and code compliance is the responsibility of the architect, building owner, contractor, installer and/or consumer. For more complete installation details, visit andersenwindows.com or see your Andersen supplier. GENERAL NOTES When ordering, make certain you specify, then verify, the exact product, unit dimensions, configuration requirements, color and options you desire on each window or patio door. Before installing the product, we suggest you verify that it includes the features and options you ordered. Visit andersenwindows.com for product installation and joining guides. Printing limitations prohibit exact color duplication of products. View actual samples for building specifications. Andersen Corporation reserves the right to change details, specifications or sizes without notice. The customer assumes all risk of alterations made to Andersen products. Example of window unit installed using Andersen published minimum rough opening dimensions. Example of two units joined together with the use of gusset plates and flat head screws that will require additional rough opening space. Interior and exterior example of window sill flashing in a membrane drainage system. INSTALLATION INFORMATION 3 ⁄8" 1 ⁄4"1 ⁄4" 1 ⁄4" 7 ⁄64" Flat Head 3 ⁄8" 1 ⁄4"1 ⁄4" 1 ⁄4" 7 ⁄64" Flat Head 3 ⁄8" 1 ⁄4"1 ⁄4" 1 ⁄4" 7 ⁄64" Flat Head 3 ⁄8" 1 ⁄4"1 ⁄4" 1 ⁄4" 7 ⁄64" Flat Head 121 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES Dimensions in parentheses are in millimeters. CODES Appropriate selection of Andersen® products that conform to all applicable laws, ordinances, building codes and safety requirements is the sole responsibility of the architect, designer, building owner and/or contractor. Check with your local building code officials for specific information. Unit wind load, performance grade and energy performance information is provided on pages 111-119. For up-to-date product performance information, visit andersenwindows.com. The performance of any building system depends on the design and construction of the building system in its entirety, which should meet building code requirements, as well as address product and material limitations, and local environment and climate. DRIP CAPS Drip caps are a specific type of flashing or trim used at the head of a window or door to direct water from the drainage plane out beyond the face of the unit. FLASHING Flashing is an important element in a building’s water management system. It is used to shed and direct water to the building exterior or to the drainage plane. Flashing materials are typically applied starting from the bottom and working upward, with each successive layer overlapping the previous one in shingle fashion. Water infiltration problems in any type of building can be reduced by properly flashing and/or sealing around all building openings, including windows and doors. USE OF SHIMS Shims are used along the side jambs of windows and doors to center the unit in the rough opening and to position it plumb, level and square. In addition, shims are always required for windows under the sill at the side jambs to lift it off the rough opening sill plate. Shims also enable a straight frame for proper weatherstrip contact and unit operation. If not placed properly, unit performance and operation can be affected. Use waterproof shims capable of supporting the weight of the product. When using tapered shims, use them in pairs with the tapers opposing each other to avoid tilting the unit or twisting (rotating) of the jambs. SEALANTS Sealants are elastic materials used to block the passage of water and/or air while allowing movement between the two sides of the joint. A sealant should bond tightly, and be able to expand and contract to accommodate joint movement without cracking or tearing away from the substrate. Surfaces must be clean, dry and sound for adequate sealant adhesion. Choose a sealant that is compatible with, and that will adhere adequately to, all building materials used in the window and patio door area. Proper sealant joint design is based upon the expected movement of adjacent materials and the movement capability of the sealant. A general rule of thumb is that the depth of the sealant joint should be equal to half the width (D = W/2), but generally not less than 1 ⁄4" (6) or more than 1 ⁄2" (13). Foam-plastic backer rod can be used to limit the depth of the sealant joint, to provide a backstop for tooling the sealant without damage to the bond. It also acts as a bond breaker to help minimize stress in the sealant. Sealants should be maintained seasonally, and repaired and/or replaced as needed. GENERAL INSTALLATION GUIDELINES 1. Read and follow the installation guide in its entirety. 2. Decide whether you are integrating to a surface barrier or a membrane drainage system before installing the product. The appropriate method for your installation may vary based on building design, application and industry practices. 3. Make certain the drainage plane is continuous (proper overlaps to shed water, taped seams, etc.). 4. Andersen products should be installed only in the vertical position. 5. Check the rough opening to make sure it is sized properly, is square and is level. 6. Install the window or door plumb. 7. Install the window or door level. 8. Install the window or door square. Diagonal measurements should be within 1⁄8" (3). 9. Follow installation instructions to properly locate shims and to make sure that units are plumb, level and square. Shims are always required under the window jambs at the sill and along the jambs on the sides for windows and doors. 10. Check for squareness of unit before final anchoring of the product into the wall. 11. Anchor unit as directed with appropriate fasteners. 12. Integrate the window and door into the drainage plane of the wall using quality flashing and sealing materials. All flashing materials should be properly overlapped to shed water. 13. Allow 1⁄4" (6) minimum space for a sealant joint around perimeter of unit between exterior finish materials and unit. 14. Insulate and seal the interior cavity between the window or door frame and the rough opening. 15. Check operation before application of interior trim. CAUTIONS 1. Do not apply any type of film to insulating glass. Thermal stress and glass damage can result. Andersen Corporation is not responsible for product performance when films are applied to Andersen products. 2. The use of removable insulating materials such as insulated window coverings, shutters and other shading devices may also cause thermal stress conditions and/or deformation of protective vinyl. In addition, excessive condensation may result, which can have a deteriorating effect on the window or door unit(s) involved. Andersen Corporation is not responsible for product performance when these kinds of materials or devices are applied to or used in conjunction with Andersen products. 3. In wall construction utilizing brick facades, leave adequate clearance between sill, jambs and brick for sealing and dimensional change of framework. 4. Acid solutions commonly used to wash brick and other masonry materials will damage glass, fasteners, hardware and metal flashing. Protect unit and follow cleaning product instructions carefully. Damage caused by acid solution is not covered under the Andersen limited warranty. 5. Andersen windows may be combined in almost unlimited ribbons or stacks if each unit is positively secured to structural elements on opposing sides and if the proper joining system is used. See page 107 for more information. SAFETY GLASS Unless specifically ordered, Andersen windows are not made with safety glass and, if broken, the glass could fragment, causing injury. Andersen windows may be ordered with tempered glass which may reduce the likelihood of injury when broken. All Andersen patio doors are made with tempered glass. Differences in appearance between tempered and non-tempered glass can be expected. Slight visual distortions may be noticeable and occur normally as a result of the tempering process. Building codes require safety glass in locations adjacent to or near doors and other locations. WINDOW AND PATIO DOOR SAFETY Windows may provide a secondary avenue of escape or rescue in an emergency, such as a fire. Every family should develop an escape plan and make sure family members know how to escape from the home in an emergency. In your plan, include two ways to escape from every room in case one way is blocked by fire or smoke, and make sure you have a designated meeting place outside. A window or a patio door is an alternate means of escape or rescue. Practice your plan until each member of the family understands it and is able to escape without assistance. Remember, you may not be able to reach children during a fire emergency. Teach children – even very young children – that they must escape from a fire in the home and never hide from the fire or from emergency personnel. LOOKOUT FOR KIDS® PROGRAM The Consumer Product Safety Commission has said: “Keep children away from open windows to prevent falls. Don’t depend on insect screens to keep the child from falling out of the window. They are designed to keep insects out, not children in. Avoid placing furniture near windows to keep children from climbing to a window seat or sill.” In an effort to educate consumers about the potential for child falls from windows, Andersen Corporation created the LookOut For Kids Program. It combines a window and door safety brochure and specific product instructions to help make window and door safety an important priority for consumers. For more information on child safety, write: Andersen Corporation LookOut For Kids Program 100 Fourth Avenue North Bayport, MN 55003 Call 800-313-8889 or email lofk@andersencorp.com 122 INSTALLATION INFORMATION LEED V4 FOR BUILDING DESIGN AND CONSTRUCTION: NEW CONSTRUCTION AND MAJOR RENOVATIONS Integrative Process Credit: Energy & Atmosphere – Minimum energy performance prerequisite – Optimize energy performance credit – Renewable energy production credit – Green power and carbon offsets credit Materials & Resources – Construction and demolition waste management planning credit – Building product disclosure and optimization sourcing of raw materials credit – Construction and demolition waste management credit Indoor Environmental Quality – Minimum indoor air quality performance prerequisite – Minimum acoustic performance prerequisite – schools – Enhanced indoor air quality strategies credit – Low-emitting materials credit – Thermal comfort credit – Daylight credit – Quality views credit – Acoustic performance credit (option 2) LEED V4 FOR BUILDING DESIGN AND CONSTRUCTION: HOMES AND MULTI-FAMILY MIDRISES Energy & Atmosphere – Minimum energy performance prerequisite – Education of the homeowner, tenant or building prerequisite – Annual energy use credit – Building orientation for passive solar credit – Air infiltration credit – Windows credit Materials & Resources – Durability management prerequisite – Environmentally preferable products credit – Construction waste management credit Indoor Environmental Quality – Ventilation prerequisite – Low-emitting products credit ANSI ICC/ASHRAE 700-2015 NATIONAL GREEN BUILDING STANDARD NGBS section numbers are referenced in parentheses. Resource Efficiency – Prefinished materials (601.7) – Flashing (602.12) – Exterior doors, including storm doors (602.1.10) – Recycled construction materials (605.3) – Bio-based products (606.1) – Wood-based products (606.2) – Manufacturer’s environmental management system concepts (611.1) Energy Efficiency – Mandatory requirements (701.1) – Building thermal envelope air sealing (701.4.3.1) – Multi-family air leakage alternative (701.4.3.3) – Fenestration air leakage (701.4.3.4) – ICC IECC analysis (702.2.1) – Energy performance analysis (702.2.2) – UA improvement (703.2.1) – Fenestration (703.2.5) – Sun-tempered design (703.7.1) – Passive cooling design (703.7.3) – Passive solar heating design (703.7.4) Indoor Environmental Quality – Wood materials (901.4) – Interior architectural coatings (901.9) – Interior adhesives & sealants (901.9) – Operable windows & sliding glass doors (902.1.5) Energy Efficient – Homeowner’s manual (1001.1) – Building construction manual (1002.1) Andersen® windows and patio doors can make significant contributions to the success of sustainable design strategies As a charter member of the U.S. Green Building Council, we’re active supporters of certified green buildings. Our products can help customers in pursuing green building programs, such as Leadership in Energy and Environmental Design (LEED®), the National Green Building Standard, Green Globes, GreenStar and more. Below is an overview of how our products may assist project teams with pursuing LEED v4 or the NAHB National Green Building Standard rating systems. More detailed credit summaries, as well as information about how Andersen products can support earlier versions of LEED certification (e.g., LEED v3 or LEED 2008), are available at andersenwindows.com. 123 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 100 SERIES *Visit andersenwindows.com/warranty for details. All logos and marks are trademarks of their respective owners. WINDOW & DOOR MANUFACTURERS ASSOCIATIONWDMA THE ENVIRONMENT HAS A BUSINESS PARTNER Respect for the environment is nothing new at Andersen. For more than a century, it has been part of who we are. Our commitment to recycle and reclaim materials began simply because it was good business. Now it’s part of our broader commitment to sustainability and responsible stewardship of all of our resources. Andersen is committed to providing you with long-lasting,* energy-efficient windows and patio doors. Visit andersenwindows.com/sustainability for more information. Andersen Corporation is proud to be an ENERGY STAR® partner. For over 120 years, Andersen has built a reputation for environmental stewardship and energy-efficient products. In fact, Andersen has been part of the ENERGY STAR program since it started and was the first window manufacturer to be named an ENERGY STAR National Window Partner of the Year in 1999. 100 Series windows and doors are Recycled Content Certified by SCS Global Services. For values and certificate details, visit andersenwindows.com/environmental. The Window & Door Manufacturers Association (WDMA) Hallmark Certification program includes product testing and quality-control process audits to verify that Andersen windows and doors are produced in conformance with the industry standards for air, water resistance and structural performance. Andersen® products are certified under the National Fenestration Rating Council (NFRC) voluntary third-party certification program designed to ensure accurate energy performance ratings and labeling. 100 Series windows and doors are Indoor Advantage Gold™ Certified by SCS Global Services for indoor air quality. Andersen was the first window manufacturer to certify products for indoor air quality, beginning in 2008. For products covered, values, and certificate details, visit andersenwindows.com/environmental. 124 Printed on FSC® certified paper. I 10 1 10 0 S e r i e s G l i d i n g Pa t i o D o o r s 17 10 0 S e r i e s W i n d o w Ov e r v i e w 10 3 10 0 S e r i e s P a t i o D o o r Si d e l i g h t s & T r a n s o m s 20 10 0 S e r i e s C a s e m e n t & A w n i n g W i n d o w s 10 5 10 0 S e r i e s P a t i o D o o r Jo i n i n g D e t a i l s 32 10 0 S e r i e s S i n g l e - H u n g Wi n d o w s 10 6 10 0 S e r i e s P a t i o D o o r Cu s t o m S i z e s 5510 0 S e r i e s G l i d i n g Wi n d o w s 10 7 Co m b i n a t i o n D e s i g n s , Pr o d u c t P e r f o r m a n c e & I n s t a l l a t i o n 68 10 0 S e r i e s P i c t u r e , Tr a n s o m & S p e c i a l t y Wi n d o w s 88 10 0 S e r i e s W i n d o w Jo i n i n g D e t a i l s 94 10 0 S e r i e s W i n d o w Cu s t o m S i z e s 99 10 0 S e r i e s P a t i o D o o r Ov e r v i e w All trademarks where denoted are marks of their respective owners. ©2025 Andersen Corporation. All rights reserved. 12/23 Part #9045491 WEB VERSION Revised 10/2025 Acrobat will display the bookmarks panel on the right side when you open the PDF. Bookmarks are the easiest way to find specific product information. Select a topic and that page will be displayed. You can also use the embedded links to navigate between sections. All links are underlined in blue. In the bookmarks panel you can print a specific section by holding down your “Ctrl” key and clicking on the section you want to print. Then choose Print Section. Website links automatically open in your web browser. Welcome to an overview of the enhanced navigation tools available in this PDF. Before you begin be sure you are using the latest version of Adobe Acrobat Reader (March 2023), available at – https://get.adobe.com/reader/ PDF NAVIGATION TIPS BOOKMARK NAVIGATION 1 3 2 4 LINKS AND URL NAVIGATION Ctrl Top left side navigation tools. The “commenting” and “highlight” tools here. Add additional navigation tools by adjusting the default settings in Acrobat. 5 87 TOOL BAR NAVIGATION We are always looking for ways to improve. Please send feedback to webmarketing@andersencorp.com. PDF NAVIGATION TIPS (continued) Lower right side navigation tools. Click on the icon shown above to scroll through a list of additional tools. Add “Previous View” tool. Go to the lower right side navigation tools. Scroll through the list and “pin” the previous view icon A left facing arrow will be added to the tool bar allowing you to go back to the previous page you viewed. Add “Loupe Zoom” tool. Go to the lower right side navigation tools. Scroll through the list and “pin” the loupe zoom icon. The loupe icon will be added to the tool bar allowing you to zoom in on details without changing the page view. 6 General Glen-Gery’s Hanley Plant manufactures many sizes of Klaycoat brick, with a nominal four inch bed depth, in a variety of shades and textures. The Klaycoat coatings are engobes (clay in liquid form) applied to the unfired brick body that fuse to the body during firing. The Klaycoat surface coating allows water vapor to pass through the face of the brick, unlike a glaze which is typically impervious. Unit Specifications Glen-Gery nominal four-inch Hanley brick are manufactured to conform to the American Society for Testing and Materials Standard Specifications C 216, Grade SW, Type FBX. Glen-Gery Klaycoat brick also conform to the requirements of ASTM C 216, Grade MW and all grades of ASTM C 62. Inquiries should be made for specific applications or for conformance with standards other than C 216 or C 652. When specifying this product, the specification should cite: 1) The product name and state “... as manufactured by the Hanley Plant of the Glen-Gery Corporation.” 2) Conformance to the requirements of the appropriate specification. The Grades and Types should also be specified. 3) The descriptive size of the unit and the actual unit dimensions, listed as thickness x height x length. For example: K74 as manufactured by the Hanley Plant of the Glen-Gery Corporation to conform to the requirements of ASTM C 216, Grade SW, Type FBX. The units shall be standard size having dimensions of 3-5/8" x 2-3/4" x 8". 1 Revised 6/2020 P R O D U C T P R O F I L E Design Criteria Size: Glen-Gery Klaycoat brick are available in seven sizes. Description (in.)(in.)(in.) Thickness x Height x Length *Body meets requirements of ASTM C216. Other sizes may be available on special order. Modular 3-5/8 x 2-1/4 x 7-5/8 Eng. Modular 3-5/8 x 2-3/4 x 7-5/8 Econo 3-5/8 x 3-5/8 x 7-5/8 Standard 3-5/8 x 2-1/4 x8 Eng. Standard 3-5/8 x 2-3/4 x8 Norman 3-5/8 x 2-1/4 x11-5/8 Utility 3-5/8 x 3-5/8 x 11-5/8 Dimensional Tolerances: Glen-Gery Klaycoat brick are manufactured to provide specific dimensional tolerances. The tolerances for the various unit dimensions are typically: Thickness: –3/32" to +3/32" Height: 3" or less –1/16" to +1/16" 3" to 4" –3/32" to +3/32" Length: over 6" to 8" –5/32" to +5/32" over 8" to 12" –7/32" to +7/32" Glen-Gery Klaycoat®Brick Standard 3-5/8 x 2-1/4 x 8 6.55 units/sq. ft. Engineer Standard 3-5/8 x 2-3/4 x 8 5.39 units/sq. ft. Modular 3-5/8 x 2-1/4 x 7-5/8 6.75 units/sq. ft. Engineer Modular 3-5/8 x 2-3/4 x 7-5/8 5.63 units/sq. ft. Handmade Oversized 4 x 2-3/4 x 8-1/2 5.00 units/sq. ft. Utility 3-5/8 x 3-5/8 x 11-5/8 3.00 units/sq. ft. King Narrow-Bed 3-1/8 x 2-3/4 x 9-5/8 4.55 units/sq. ft. Engineer King 2-13/16 x 2-13/16 x 9-5/8 4.55 units/sq. ft. Kingston 3-5/8 x 2-3/4 x 11-5/8 3.75 units/sq. ft. Engineer Modular 3-5/8 x 2-3/4 x 7-5/8 5.63 units/sq. ft. Queen 3 x 2-3/4 x 7-5/8 5.63 units/sq. ft. Standard 3-5/8 x 2-1/4 x 8 6.55 units/sq. ft. Modular 3-5/8 x 2-1/4 x 7-5/8 6.75 units/sq. ft. Engineer Standard 3-5/8 x 2-3/4 x 8 5.39 units/sq. ft. Econo 3-5/8 x 3-5/8 x 7-5/8 4.50 units/sq. ft. Roman 3-5/8 x 1-5/8 x 11-5/8 6.00 units/sq. ft. Norman 3-5/8 x 2-1/4 x 11-5/8 4.50 units/sq. ft. Saxon 3-5/8 x 2-1/4 x 15-5/8 3.38 units/sq. ft. Double Utility 3-5/8 x 7-5/8 x 11-5/8 1.50 units/sq. ft. Double Titan 3-5/8 x 7-5/8 x 15-5/8 2.25 units/sq. ft. Titan 3-5/8 x 3-5/8 x 15-5/8 2.25 units/sq. ft. Regent 7-5/8 x 3-5/8 x 11-5/8 3.00 units/sq. ft. 8-Square 3-5/8 x 7-5/8 x 7-5/8 2.25 units/sq. ft. Glen-Gery Brick Sizes www.glengery.com • 610-374-4011 Coring and frogs are at the manufacturer’s option. Actual coring patterns may not match the illustrations. Titan Plus 7-5/8 x 3-5/8 x 15-5/8 2.25 units/sq. ft. Double Titan Plus 7-5/8 x 7-5/8 x 15-5/8 1.13 units/sq. ft. King 3-5/8 x 2-3/4 x 9-5/8 4.55 units/sq. ft. Lightweight Modular 3-1/2 x 2-1/4 x 7-5/8 6.75 units/sq. ft. Lightweight Engineer Modular 3-1/2 x 2-3/4 x 7-5/8 5.63 units/sq. ft. Viking 3-1/2 x 1-5/8 x 15-5/8 4.50 units/sq. ft. 2 Contact plant for specific information on sizing and coring. Revised 6/2020 3 Glen-Gery Klaycoat Brick Revised 6/2020 Generally, the product ordered may contain a number of units which are over or under the specified dimension. These dimensional variations are related to the raw materials and the forming, drying, and firing processes. Thus, for an individual order, all of the units may average slightly over or slightly under the specified dimensions. Inquiries should be made regarding the dimensional variations which might be expected if the project detailing requires precise coursing. Specialty products or gauged products may be desirable for such applications. Configuration: All units are normally manufactured as solid brick to conform to the require- ments of the applicable ASTM standards. The solid unit may have cores, which cre- ate an aggregate void space, which may not exceed twenty-five percent of the gross cross-sectional area in every plane parallel to the bearing surface. The units may have three, five, or ten core holes. Variations in core size and configuration may be available on special orders. Weight: The weight of brick units varies with the raw materials, size, manufacturing process, and the amount and configuration of coring. Finishes: Glen-Gery Klaycoat brick are available smooth, wirecut, rough, stone rolled and craftsman textures. Brick having the craftsman texture may conform to Type FBS dimensional tolerances for thickness. Please note that the requirements of ASTM C 216, Paragraph 10.4, regarding distribution of color on the faces and heads of individual brick, are waived. The Modular 4.0 Engineer Modular 5.0 Econo 6.5 Standard 4.3 Engineer Standard 5.2 Norman 6.3 Utility 10.1 Description Cored Units Typical weight (lb. /unit) number and location of finished faces must be specifically stated in the Klaycoat order. Color: Glen-Gery Klaycoat brick are available in a multitude of color blends. Custom color blends are available upon request. The color range includes various shades of reds, browns, grays, blues, oranges, yellows, buffs, and whites. Because all of these colors are produced by the applied engobe, through-the-body colors are not possible. Shapes: Standard brick shapes are shapes whose dimensions course properly with standard brick and include the S2 Jamb Quoin (coated on one stretcher face and one head) and the S80 Header (coated on one head only). Standard brick shapes are not stock items. The standard size brick shapes are described in the Glen-Gery Standard Shapes Catalog, “Brick Shapes.” The typical extruded brick shapes, as described in the catalog, include various configurations of bullnose, watertable, octagon, shelf -angle, sill, and coping units. Shapes dimensioned for coursing with other brick sizes and shapes having configurations to fit specific project requirements are also available. All shapes require detailed dimension drawings, which must be submitted to Glen-Gery and confirmed. All shapes must be identified early in the project design, because certain shape configurations may require special forming, drying, or firing processes. These processes may require more time or different scheduling than the Klaycoat stretchers. Note that some shape designs may require special coring in order to achieve the effects desired by the designer. Physical Properties of Units Compressive Strength: The average compressive strength of Glen-Gery Klaycoat brick exceeds 3,000 psi when tested with loads applied normal to the bedding surface. Typically, the average compressive strength of Klaycoat brick exceeds 8,000 psi and may be as high as 14,000 psi. The actual compressive strength is dependent upon the specific product selected. Water Absorption: The average maximum water absorption by submersion in boiling water for five hours is less than 17% and will typically be less than 5% for Glen-Gery Klaycoat brick. The average saturation coefficient will typically exceed 0.78. In these instances, the cold-water absorption is less than 8% and is often less than 4% and the units are in compliance with the requirements of ASTM C 216, Grade SW, or C 652, Grade SW. Initial Rate of Absorption (IRA): The initial rate of absorption (suction) of Glen-Gery Klaycoat brick normally does not exceed 20 grams per 30 square inches per minute under laboratory conditions. However, all brick should be checked to determine if wetting is necessary, unless familiarity with the product has demonstrated that wetting is not required. The procedure for determining wetting requirements should be in accordance with the field test procedure described in ASTM C 67. Because of the generally low suctions of Klaycoat brick, it is imperative that the handling instructions contained in this profile be precisely followed to reduce the possibility of brick floating during cool, damp, and still conditions. Properties of Walls Compressive Strength: The minimum assumed compressive strength for a wall constructed of Glen-Gery Klaycoat units, using good workmanship and Type "S" portland cement/lime mortar is 735 psi. Most Glen-Gery Klaycoat brick, when used with good workmanship and Type "S" portland cement/lime mortar, will provide a mini- mum compressive strength of 1,435 psi. Specific products may provide assumed compressive strengths as high as 2,600 psi. Reference: Brick Institute of America (BIA) Recommended Practice for Engineered Brick Masonry. Thermal Performances: The thermal resistivity of Glen-Gery’s Klaycoat brick is approximately 0.15 (hr. • sq. ft. • deg F) /(BTU• in.). A nominal four-inch wythe, excluding air films will provide a thermal resistance of approximately 0.54. The thermal resistivity 4 is used to predict the thermal performance of wall elements under steady state conditions. The mass and the specific heat of the product provides additional benefits when subjected to the dynamic conditions of the natural environment. As described in the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) Standard 90, the effects of mass, specific heat, and the color of the brick should be considered. Reference: BIA Technical Notes on Brick Construction: 4 "Introduction to Energy Performance of Brick Masonry;" and 4B Revised, “Energy Code Compliance of Brick Masonry Walls.” Sound Transmission: A nominal four-inch wythe of brickwork has a sound transmission classification (STC) of approximately 45. Reference: BIA Technical Notes on Brick Construction: 5A “Sound Insulation – Clay Masonry Walls.” Fire Resistance: A nominal 3-5/8" wythe of load bearing brickwork has an ultimate fire resistance period of approximately 1-1/4. hours. This provides a one-hour rating. Reference: BIA Technical Notes on Brick Construction: 16, “Fire Resistance of Brick Masonry.” Coefficient of Thermal Expansion: Brick walls constructed of Glen-Gery Klaycoat brick-have a coefficient of thermal expansion of approximately 0.000004 in./(in • deg F). A wall one hundred feet long (or high) constructed of Glen-Gery Klaycoat brick and exposed to an annual extreme temperature difference of 100 degrees F would be expected to experience a total thermal movement of approximately one-half inch. Coefficient of Moisture Expansion: The coefficient of moisture expansion of Glen-Gery Klaycoat brick is typically less than 0.00065 in./in. (0.065%). Much of the moisture expansion of Glen-Gery Hanley Klaycoat brick occurs shortly after the brick have been fired and before the brick arrive on the job site. The maximum expected moisture expansion of a wall 100 feet long (or high) may be three- quarters of an inch. Construction Storage: It is imperative that Klaycoat brick be stored off of the ground to avoid contamination by mud, dust, water, or materials likely to cause staining, charging with soluble salts, or other defects. Protection: It is imperative that Klaycoat brick be covered with a waterproof membrane held securely in place or be otherwise protected from the elements. Wetting: As deemed necessary, wet units prior to laying. However, wetting is rarely required for Klaycoat units. Wetting typically consists of saturating the units three to twenty-four hours before laying the units. Units which have been wet should be surface dry when laid. Cold Weather: Follow the procedures developed by the International Masonry Industry All- Weather Council (IMIAC). Reference: IMIAC “Recommended Practice and Guide Specifications for Cold Weather Masonry Construction” and BIA Technical Notes on Brick Construction, 1, “Hot and Cold Weather Construction.” Installation: Place units in full mortar joints. The mortar used to lay Klaycoat brick must be mixed from ASTM C 150 portland cement, ASTM C 207, Type S, hydrated lime, ASTM C 144 sand, and clean, potable water. Except for ASTM C 979 mineral aggregate pigments, there must be no substitutions, additions or deletions to these ingredients. Depend- ing upon the design conditions and the installation conditions, such as weather, the mortar may be proportioned to meet the requirements of ASTM C 270 Type S or Type N mortar. Note that Type N mortars provide greater resistance to water penetration, while Type S mortars provide greater resistance to flexural stresses. A prepackaged mortar mix conforming to these specifications is Glen-Gery Color Mortar Blend. Reference: Glen-Gery Color Mortar Product Profile. Keys to Successful Performance: Extraneous water must be kept from saturating the brickwork. This is successfully done by: 1) Placing flashings above window and door heads, under window sills, at the top of the brickwork, below the first course of Klaycoat brick (as a dampproof course), at shelf angles, at changes in construction, and wherever conditions require protection of the brickwork from water. 2) Avoiding parapet walls, but if they must be used, taking special care in design, construction, and workmanship. NOTE: Venting cavities at the top and bottom has been proven to allow the wall to weep, breathe, and dry quicker. 3) Following the recommendations discussed in other parts of this document. Tooling: Tool all joints when thumbprint hard to produce a concave joint profile. Do not use struck, flush, or raked joints. Protection of the Work: At the end of each day or shut down period, it is imperative that all partially completed masonry work, including work at window and door sills and jambs and under unroofed areas, be covered with a strong waterproof membrane held securely in place. Cleaning: Clean with wooden paddles and stiff fiber bristle brushes using clean water. If a cleaning agent is necessary, contact your local Glen-Gery Sales office. If a cleaning agent is to be used, test the cleaning agent on a small sample area to observe the effectiveness of the cleaning agent and, most importantly, to detect possible deleterious effects or changes in appearance. Always presoak the wall prior to applying the cleaning agent and thoroughly rinse the wall with clean water after cleaning. Diedrich 202V Vana-Stop will generally perform effectively, but your local Glen-Gery Sales office should be consulted before the selection of a Glen-Gery Klaycoat Brick Revised 6/2020 Glen-Gery Klaycoat Brick Revised 6/2020 5 cleaning chemical is made. Cleaning should never occur prior to 7 calendar days after work is completed to assure appropriate curing of the mortar. Reference: BIA Technical Notes on Brick Construction 20, “Cleaning Brickwork.” Estimating: The quantities of brick and mortar required for a project vary with the wall construction, the number of field cuts necessary, the coring configuration of the units, and the workmanship. Table 1 provides the quantities of brick and mortar per square foot of wall and mortar quantities per 1000 brick units. These figures are based upon the units being placed in the wall as stretchers in stack or running bond. The values provided are estimates of the quantities in the finished wall and do not account for waste. The values found in Table 2 may be useful for approximating the number of units for caps, sills, bands, etc. These values represent the actual number of units per linear foot for the most frequently used positions of the brick in the wall. For further information contact: Glen-Gery Technical Services 433 South Pottsville Pike Shoemakersville, PA 19555 (610) 562-3076 1 These values are actual quantities and must be increased for waste and any possible construction requirements which may necessitate additional quantities. *Bags includes cement mixed with 3 parts of sand. Modular Engineer Modular Econo Standard Engineer Standard Norman Utility 8.10 8.52 9.15 6.29 8.81 11.24 12.29 5.46 4.79 4.12 6.55 4.75 5.06 3.69 6.75 5.63 4.50 6.55 5.39 4.50 3.00 3 Courses per 8" 5 Courses per 16" 2 Course per 8" 3 Courses per 8" 5 Courses per 16" 3 Courses per 8" 1 Course per 4" Descriptive Unit Size Vertical Coursing in courses per inch Units per square foot Cubic Foot per 100 square foot Quantity of Mortar per 1000 units (bags*) TABLE 1 Brick and Mortar Quantities1 Nominal 3/8 Inch Mortar Joints TABLE 2 Units Per Linear Foot in Various Positions Nominal 3/8 Inch Mortar Joints Modular Engineer Modular Econo Standard Engineer Standard Norman Utility 3.00 3.00 3.00 3.00 3.00 3.00 3.00 4.50 3.75 3.00 4.50 3.75 4.50 3.00 4.50 3.75 3.00 4.50 3.75 4.50 3.00 1.50 1.50 1.50 1.43 1.43 1.00 1.00 Brick Size Stretcher Rowlock Soldier Header Glen-Gery Klaycoat Brick Revised 6/2020 6 This document is furnished for informational purposes only and is NOT intended as an EXPRESSED WARRANTY. Glen-Gery accepts no liability for the use of this information. All information should be independently evaluated by a qualified design professional in the context of the specific circumstances in which it is to be applied. Seller warrants title to said goods and that the goods supplied shall meet applicable specifications where such are designated in the Buyer’s order. Should the said goods fail to conform to the foregoing warranty, Seller will, at its option replace the same, F.O.B. job site or refund the portion of purchase price paid for such non-conforming goods. SELLER SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR ANY BREACH OF THESE WARRANTIES. THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, INCLUDING, WITHOUT LIMITATION, WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. 610.374.4011 info@ glengery.com www.glengery.com ©2020 Glen-Gery 6/20/ LSD LDN6CYL 6" CYLINDER Non-IC ORDERING INFORMATION Example: LDN6CYL 35/15 LO6AR LSS MVOLT EZ1 FCM DWHG DOWNLIGHTING LDN6CYL Lead times will vary depending on options selected. Consult with your sales representative. Notes 1 Not available in ACC mount. 2 Not available with finishes. 3 Refer to TECH-240 for compatible dimmers. 4 Supplied with 10” supply and dimming connections. 5 White cord supplied with white housings. All other finishes supplied with black cord. 6 Must specify voltage 120V or 277V. 7 Specify voltage. ER for use with generator supply EM power. Will require an emergency hot feed and normal hot feed. 8 Interface remote mounted. Access panel (supplied by others) recommended. 9 Not available with ACC & ACC180 mounting options. 10 Additional architectural colors available; see www.lithonia.com/archcolors. 11 Color and length of stem must be specified (from 6” to 240” in even increments in maximum sections of 48”). Ex.: CYS06 DWHG. Ceiling attachment for interior use. Consult factory for exterior. 12 Must be field-installed to an accessible remote-mounted junction box. Catalog Number Notes Type LDN6CYL Series Color temperature Lumens Aperture/Trim Color Finish Voltage LDN6CYL 6" cylinder 27/2700K 30/3000K 35/3500K 40/4000K 50/5000K 05 500 lumens 07 750 lumens 10 1000 lumens 15 1500 lumens 20 2000 lumens 25 2500 lumens 30 3000 lumens 40 4000 lumens 50 5000 lumens LO6 Downlight LW61 Wallwash AR Clear WR2 White BR2 Black LSS Semi-specular LD Matte diffuse LS Specular MVOLT Multi-volt 120 120V 277 277V Driver3 Mounting Options6 Architectural Colors10,11 GZ10 0-10V driver dims to 10% GZ1 0-10V driver dims to 1% EZ10 0-10V eldoLED driver with smooth and flicker-free deep dimming performance down to 10% EZ1 0-10V eldoLED driver with smooth and flicker-free deep dimming performance down to 1% FCM Ceiling mount WM Wall mount PM4 Pendant 3/8” thread mount ACC 5 10ft aircraft cable and cord mount ACC1805 15ft aircraft cable and cord mount SF6 Single fuse NPP16D7,8 nLight® network power/relay pack with 0-10V dimming for non-eldoLED drivers (GZ10, GZ1). NPP16DER7,8 nLight® network power/relay pack with 0-10V dimming for non-eldoLED drivers (GZ10, GZ1). ER controls fixtures on emergency circuit. NPS80EZ7,8 nLight® dimming pack controls 0-10V eldoLED drivers (EZ10, EZ1). NPS80EZER7,8 nLight® dimming pack controls 0-10V eldoLED drivers (EZ10, EZ1). ER controls fixtures on emergency circuit. 90CRI High CRI (90+) WL9 Wet location DWHG Matte white DDB Dark bronze DBL Black DWH Glossy white DMB Medium bronze DNA Natural aluminum DSS Sandstone DGC Charcoal grey DTG Tennis green DBR Bright red DSB Steel blue D IM M AB L E FEATURES & SPECIFICATIONS INTENDED USE — Typical applications include corridors, lobbies, conference rooms and private offices. CONSTRUCTION — Heavy-gauge aluminum housing. Ceiling mount for direct installation to 4” octagonal or square junction box. Pendant mount entry for 3/8” National Pipe Thread stem; wires supplied by others. Textured polyester powder paint finish standard. Multiple ceiling, pendant, cord, and wall mount options available. OPTICS — LEDs are binned to a 3-step SDCM; 80 CRI minimum. 90 CRI optional. LED light source concealed with diffusing optical lens. General illumination lighting with 1.0 S/MH and 55° cutoff to source and source image. Self-flanged anodized reflectors in specular, semi-specular, or matte diffuse finishes. Also available in white and black painted reflectors. ELECTRICAL — Multi-volt (120-277V, 50/60Hz) 0-10V dimming drivers mounted to junction box, 10% or 1% minimum dimming level available. 347V available option; transformer must be field-installed to an accessible remote-mounted junction box. 0-10V dimming fixture requires two (2) additional low-voltage wires to be pulled. 70% lumen maintenance at 60,000 hours. LISTINGS — Certified to US and Canadian safety standards. Damp location standard (wet location, covered ceiling optional). ENERGY STAR® certified product. WARRANTY — 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. A+ Capable options indicated by this color background. LDN6CYL DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/25/20 LDN6CYL LDN6 35/10 LO6AR, input watts: 10.44, delivered lumens: 987.10, LM/W = 94.54, spacing criterion at 0= 1.02, test no. ISF 30716P262. LDN6 35/15 LO6AR, input watts: 17.52, delivered lumens: 1572.9, LM/W = 87.45, spacing criterion at 0= 1.02, test no. ISF 30716P265. LDN6 35/30 LO6AR, input watts: 34.75, delivered lumens: 3138.5, LM/W = 90.31, spacing criterion at 0= 1.02, test no. ISF 30716P274. PHOTOMETRY Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance Data at 30” Above Floor for a Single Luminaire Accessories: Order as separate catalog number. (shipped separately) CYS11 3/8" stem and canopy with 5° "hang straight" swivel CRS11 3/8" stem and canopy with 45° swivel SDT 347/120 75VA12 347V Step-down transformer PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P262 Lithonia Lighting LDN6 35/10 LO6AR LS 6IN LDN, 3500K, 1000LM, CLEAR, SPECULAR REFLECTOR, CRI80 987.0469 LED LDN6 Round Series f10c02be-762d-40f0-9a15-d770f5aadb94 6 RECESSED DOWNLIGHT 987.1 10.44 -0.52, -0.52, 0 0° 20° 40° 60° 80° 200 400 600 800 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 876 905 971 720 330 110 1 1 0 0 0 89 269 322 214 87 4 1 0 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 680.7 895.0 986.0 987.0 0.0 0.0 0.0 0.0 987.0 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80%70%50% pw 50%30%10% 50%30%10% 50%30%10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RC R 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 29.0 15.6 9.7 6.6 4.8 5.7 7.7 9.8 11.8 13.9 14.5 7.8 4.9 3.3 2.4 9.6 13.1 16.6 20.1 23.6 2.9 1.6 1.0 0.7 0.5 Spacing to Mounting Height:1.0 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P265 Lithonia Lighting LDN6 35/15 LO6AR LS 6IN LDN, 3500K, 1500LM, CLEAR, SPECULAR REFLECTOR, CRI80 1572.875 LED LDN6 Round Series 353e6a9b-84c5-4dbd-9a8d-3e8e112b9264 6 RECESSED DOWNLIGHT 1572.9 17.52 -0.52, -0.52, 0 0° 20° 40° 60° 80° 600 1200 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 1396 1442 1547 1147 526 176 2 1 1 0 0 142 429 514 342 139 6 1 1 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 1084.6 1426.2 1571.3 1572.9 0.0 0.0 0.0 0.0 1572.9 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80%70%50% pw 50%30%10% 50%30%10% 50%30%10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RC R 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 46.2 24.8 15.5 10.6 7.7 5.7 7.7 9.8 11.8 13.9 23.1 12.4 7.7 5.3 3.8 9.6 13.1 16.6 20.1 23.6 4.6 2.5 1.5 1.1 0.8 Spacing to Mounting Height:1.0 PRINT DATE: TEST NO: MANUFACTURER: LUMINAIRE CATALOG NO.: LUMINAIRE DESCRIPTION: LUMENS PER LAMP: [_LAMPTYPE] [_FAMILY] [_PRODUCTID] [_APERTURE] [_MOUNTING] [_TOTALLUMINAIRELUMENS] [_INPUTWATTAGE] [_PHYSICALDIMENSIONS] July 25, 2019 ISF 30716P274 Lithonia Lighting LDN6 35/30 LO6AR LS 6IN LDN, 3500K, 3000LM, CLEAR, SPECULAR REFLECTOR, CRI80 3138.479 LED LDN6 Round Series d5b00a16-a91a-46b1-8fc1-15e68906b538 6 RECESSED DOWNLIGHT 3138.5 34.75 -0.52, -0.52, 0 0° 20° 40° 60° 80° 1200 2400 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 2786 2877 3087 2289 1049 350 5 2 1 0 0 284 855 1025 682 277 12 2 1 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 2164.3 2845.9 3135.3 3138.5 0.0 0.0 0.0 0.0 3138.5 69.0 90.7 99.9 100.0 0.0 0.0 0.0 0.0 *100.0 *Efficiency Coefficients of Utilization pf 20% pc 80%70%50% pw 50%30%10% 50%30%10% 50%30%10% 0 1 2 3 4 5 6 7 8 9 10 119 111 103 96 89 83 78 73 69 65 61 119 108 99 91 84 77 72 67 63 59 55 119 106 95 87 79 73 68 63 59 55 51 116 109 101 94 88 82 77 73 68 64 61 116 106 97 90 83 77 72 67 62 59 55 116 104 94 86 79 73 67 63 58 55 51 111 104 98 92 86 81 76 71 67 63 60 111 103 95 88 81 76 71 66 62 58 55 111 101 92 85 78 72 67 62 58 54 51 RC R 50% beam - 54.5° 10% beam - 82.2° Mounting Height Inital FC Center Beam Diameter FC Diameter FC 8.0 10.0 12.0 14.0 16.0 92.1 49.5 30.9 21.1 15.3 5.7 7.7 9.8 11.8 13.9 46.1 24.8 15.4 10.5 7.6 9.6 13.1 16.6 20.1 23.6 9.2 5.0 3.1 2.1 1.5 Spacing to Mounting Height:1.0 LDN6CYL DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/25/20 LDN6CYL * All dimensions are inches (centimeters) unless otherwise noted. A SECTION A-A SCALE 1 : 1LDN 6 INCH CYLINDER WALL MOUNT LDN 6 CYLINDER LUMEN OUTPUT STYLE DIM "A"DIM "B"DIM "C"DIM "D"DIM "E"DIM "F"500-3000 LM CEILING MOUNT (FCM)11 5/16 8 1/8 ---- 500-3000 LM CEILING MOUNT WET LOCATION (FCM WL)11 5/16 8 1/8 ---- 500-3000 LM PENDANT MOUNT (PM)10 1/2 8 1/8 ---- 500-3000 LM PENDANT MOUNT WET LOCATION (PM WL)11 1/2 8 1/8 ---- 500-3000 LM CABLE MOUNT (ACC)10 5/16 8 1/8 ---- 500-3000 LM WALL MOUNT (WM)--10 1/16 8 1/8 11 1/2 6 3/8500-3000 LM WALL MOUNT WET LOCATION (WM WL)--11 3/16 8 1/8 11 1/2 6 3/84000-5000 LM CEILING MOUNT (FCM)11 3/8 10 1/4 ---- 4000-5000 LM CEILING MOUNT WET LOCATION (FCM WL)11 3/8 10 1/4 ---- 4000-5000 LM PENDANT MOUNT (PM)10 3/4 10 1/4 ---- 4000-5000 LM PENDANT MOUNT WET LOCATION (PM WL)11 1/2 10 1/4 ---- 4000-5000 LM CABLE MOUNT (ACC)10 3/8 10 1/4 ---- 4000-5000 LM WALL MOUNT (WM)--10 1/16 10 1/4 13 1/2 6 3/84000-5000 LM WALL MOUNT WET LOCATION (WM WL)--11 3/16 10 1/4 13 1/2 6 3/8 DIM "A" DIM "C" DIM "D" DIM "E" DIM "F" 3 516 [8.3] 5 516 [13.5] DIM "B" DIMENSION TABLE LUMEN OUTPUT STYLE DIM "A"DIM "B"DIM "C"DIM "D"DIM "E"DIM "F" 500-3000 LM CEILING MOUNT (FCM)11 5/16 8 1/8 500-3000 LM CEILING MOUNT WET LOCATION (FCM WL)11 5/16 8 1/8 500-3000 LM PENDANT MOUNT (PM)10 1/2 8 1/8 500-3000 LM PENDANT MOUNT WET LOCATION (PM WL)11 1/2 8 1/8 500-3000 LM CABLE MOUNT (ACC)10 5/16 8 1/8 500-3000 LM WALL MOUNT (WM)10 1/16 8 1/8 11 1/2 6 3/8 500-3000 LM WALL MOUNT WET LOCATION (WM WL)11 3/16 8 1/8 11 1/2 6 3/8 4000-5000 LM CEILING MOUNT (FCM)11 3/8 10 1/4 4000-5000 LM CEILING MOUNT WET LOCATION (FCM WL)11 3/8 10 1/4 4000-5000 LM PENDANT MOUNT (PM)10 3/4 10 1/4 4000-5000 LM PENDANT MOUNT WET LOCATION (PM WL)11 1/2 10 1/4 4000-5000 LM CABLE MOUNT (ACC)10 3/8 10 1/4 4000-5000 LM WALL MOUNT (WM)10 1/16 10 1/4 13 1/2 6 3/8 4000-5000 LM WALL MOUNT WET LOCATION (WM WL)11 3/16 10 1/4 13 1/2 6 3/8 LUMEN OUTPUT MULTIPLIERS - FINISH Clear (AR)White (WR)Black (BR) Specular (LS)1.0 N/A N/A Semi-specular (LSS)0.950 N/A N/A Matte diffuse (LD)0.85 N/A N/A Painted N/A 0.87 0.73 LUMEN OUTPUT MULTIPLIERS - CCT 2700K 3000K 3500K 4000K 5000K 80CRI 0.950 0.966 1.000 1.025 1.101 LDN6CYL Nominal Lumens Lumens Wattage Lm/W 500 527.9 5.8 90.5 750 758.1 8.9 85.1 1000 950.1 10.4 91.0 1500 1514 17.5 86.4 2000 2006 22.5 89.1 2500 2504 28.3 88.6 3000 3021 34.8 86.9 4000 4008 44.3 90.6 5000 4975 57.7 86.3 LDN6CYL DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2015-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/25/20 LDN6CYL ADDITIONAL DATA nLight® Control Accessories: Order as separate catalog number. Visit www.sensorswitch.com/nLight for complete listing of nLight controls. WallPod stations Model number Occupancy sensors Model number On/Off nPODM [color]Small motion 360°, ceiling (PIR / dual tech)nCM 9 / nCM PDT 9 On/Off & Raise/Lower nPODM DX [color]Large motion 360°, ceiling (PIR / dual tech)nCM 10 / nCM PDT 10 Graphic Touchscreen nPOD GFX [color]Wide view (PIR / dual tech)nWV 16 / nWV PDT 16 Photocell controls Model number Wall Switch w/ Raise/Lower (PIR / dual tech) nWSX LV DX / nWSX PDT LV DX Dimming nCM ADCX Cat-5 cables (plenum rated)Model number 10', CAT5 10FT CAT5 10FT J1 15', CAT5 15FT CAT5 15FT J1 A A B B A nPS 80 EZ nCM ADCX nCM PDT 9 nPS 80 EZ nPODM 2P DX B C C A OPTIONAL WIRING KEY BA C CAT-5e Cable Line Power Low VoltageDimming Wires Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning. • All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency • This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background* • This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background* To learn more about A+, visit www.acuitybrands.com/aplus. *See ordering tree for details COMPATIBLE 0-10V WALL-MOUNT DIMMERS MANUFACTURER PART NO.POWER BOOSTER AVAILABLE Lutron® Diva® DVTV Diva® DVSCTV Nova T® NTFTV Nova® NFTV Leviton® AWSMT-7DW CN100 AWSMG-7DW PE300 AMRMG-7DW Leviton Centura Fluorescent Control System IllumaTech® IP7 Series Synergy® ISD BC RDMFCSLD LPCS Digital Equinox (DEQ BC) Douglas Lighting Controls WPC-5721 Entertainment Technol- ogy Tap Glide TG600FAM120 (120V) Tap Glide Heatsink TGH1500FAM120 (120V) Oasis 0A2000FAMU Honeywell EL7315A1019 EL7305A1010 (optional)EL7315A1009 HUNT Dimming Preset slide: PS-010-IV and PS-010-WH Preset slide: PS-010-3W-IV and PS-010-3W-WH Preset slide, controls FD-010: PS-IFC-010-IV and PS-IFC-010-WH-120/277V Preset slide, controls FD-010: PS-IFC-010-3W-IV and PS-IFC-010-3W-WH-120/277V Remote mounted unit: FD-010 Lehigh Electronic Products Solitaire PBX PDM Electrical Products WPC-5721 Starfield Controls TR61 with DALI interface port RT03 DALInet Router WattStopper®LS-4 used with LCD-101 and LCD-103 Project Name/Number/Date 07 42 43-1 Composite Wall Panels Illumination Series Three-Part Specification 07 42 43 Composite Wall Panels Part I - General 1.1 SECTION INCLUDES: A. Exterior, panelized fiber cement cladding system and accessories to complete a drained and back-ventilated rainscreen. B. Interior fiber cement panelized cladding system and accessories. 1.2 RELATED SECTIONS A. Section 05 41 00 - Structural Metal Stud Framing B. Section 06 10 00 - Rough Carpentry C. Section 06 16 00 - Sheathing D. Section 07 20 00 - Thermal Protection E. Section 07 25 00 - Weather Barriers F. Section 07 60 00 - Flashing and Sheet Metal G. Section 07 90 00 - Joint Protection 1.3 REFERENCES A. American Architectural Manufacturers Association (AAMA): 1. AAMA 509-14 – Voluntary Test and Classification Method of Drained and Back Ventilated Rain Screen Wall Cladding Systems B. ASTM International (ASTM): 1. ASTM C 518 - Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. 2. ASTM C 1185 - Standard Test Methods for Sampling and Testing Non-Asbestos Fiber Cement. a. ASTM C 1186 – Standard Specification for Flat Fiber-Cement Sheets. 3. ASTM E-84 - Standard Test for Surface Burning Characteristics of Building Materials. 4. ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials. 5. ASTM E 228 - Standard Test Method for Linear Thermal Expansion of Solid Materials with a Vitreous Silica Dilatometer. Project Name/Number/Date 07 42 43-2 Composite Wall Panels 6. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 7. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. C. Florida Building Code - Test Protocol HVHZ 1. Testing Application Standard (TAS) 202, 203 – HVHZ Test Procedures D. National Fire Protection Association (NFPA): 1. NFPA 285 - Fire Test Method for Exterior Wall Assemblies Containing Combustible Material. 2. NFPA 268 – Ignition Resistance of Exterior Wall Assemblies. E. Standards Council of Canada & Underwriters Laboratories Canada (ULC): 1. CAN/ULC S-102 – Standard Method of Test for Surface Burning Characteristics. 2. CAN/ULC S-134 – Standard Method of Fire Test of Exterior Wall Assembly. 1.4 SUBMITTALS A. Submit under provisions of Section 01 33 00. B. Product Data: Submit manufacturer’s product description, storage and handling requirements, and installation instructions. C. Product Test Reports and Code Compliance: Documents demonstrating product compliance with local building code, such as test reports or Evaluation Reports from qualified, independent testing agencies. D. LEED Credits: Provide documentation of LEED Credits for project certification under USGBC LEED 2009 (Version 3.0) or 2012 v.4. E. Manufacturer’s Details: Submit drawings (.dwg, .rvt, and/or .pdf formats), including plans, sections, showing installation details that demonstrate product dimensions, edge/termination conditions/treatments, compression and control joints, corners, openings, and penetrations. F. Samples: Submit samples of each product type proposed for use. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: 1. All fiber cement panels specified in this section must be supplied by a manufacturer with a minimum of 10 years of experience in fabricating and supplying fiber cement cladding systems. a. Products covered under this section are to be manufactured in an ISO 9001 certified facility. Project Name/Number/Date 07 42 43-3 Composite Wall Panels 2. Provide technical and design support as needed regarding installation requirements and warranty compliance provisions. B. Installer Qualifications: All products listed in this section are to be installed by a single installer trained by manufacturer or representative. C. Mock-Up Wall: Provide a mock-up wall as evaluation tool for product and installation workmanship. D. Pre-Installation Meetings: Prior to beginning installation, conduct conference to verify and discuss substrate conditions, manufacturer’s installation instructions and warranty requirements, and project requirements. 1.6 DELIVERY, STORAGE, AND HANDLING A. Panels must be stored flat and kept dry before installation. A waterproof cover over panels and accessories should be used at all times prior to installation. Do not stack pallets more than two high. Refer to the information included on each pallet. B. If panels are exposed to water or water vapor prior to installation, allow to completely dry before installing. Failure to do so may result in panel shrinkage at ship lap joints, and such action may void warranty. C. Panels MUST be carried on edge. Do not carry or lift panels flat. Improper handling may cause cracking or panel damage. D. Direct contact between the panels and the ground should be avoided at all times. It is necessary to keep panels clean during installation process. 1.7 WARRANTY A. Provide manufacturer’s 15-year warranty against manufactured defects in fiber cement panels. Additional 5-year extension available when refinished in year 14-15. B. Provide manufacturer’s 15-year warranty against manufactured defects in panel finish. C. Warranty provides for the original purchaser. See warranty for detailed information on terms, conditions and limitations. PART II: PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Nichiha Corporation, 18-19 Nishiki 2-chome Naka-ku, Nagoya, Aichi 460-8610, Japan. Project Name/Number/Date 07 42 43-4 Composite Wall Panels B. Acceptable Manufacturer’s Representative: Nichiha USA, Inc., 6465 E. Johns Crossing, Suite 250, Johns Creek, GA 30097. Toll free: 1.866.424.4421, Office: 770.805.9466, Fax: 770.805.9467, www.nichiha.com. 1. Basis of Design Product: Nichiha Illumination Series. a. Profile colors: Designer-specified custom color (finished in U.S.). b. Profiles: 1. AWP-1818 Panel: Smooth, no score lines. 2. AWP-3030 Panel: Smooth, No score lines. Wider, soft-U chamfered edge at horizontal joints. i. Do not pair the different sizes directly together. c. Accessory/Component Options: i. Manufactured Corners with 3-1/2” returns for each profile size and color. a. Do not use AWP-1818 Corners with AWP-3030 Panels. ii. Aluminum trim options: Corner Key, Open Outside Corner, H-Mold, J-Mold, Compression Joint, Inside Corner 1. Finish: Custom Color, Clear Anodized, or Primed. iii. Essential Flashing System: Starter, Overhang. 1. Finish: Matte black. d. Dimensions: 1. AWP-1818: 455mm (17-7/8”) (h) x 1,818 mm (71-9/16”) (l). 2. AWP-3030: 455mm (17-7/8”) (h) x 3,030 mm (119-5/16”) (l). e. Panel Thickness: 16 mm (5/8"). f. Weight: AWP-1818: 35.27 lbs. per panel, AWP-3030: 57.32 lbs. per panel. g. Coverage: 8.88 sq. ft. per panel (1818), 14.81 sq. ft. per panel (3030). h. Factory sealed on six [6] sides. C. Substitutions: Not permitted. D. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00. 2.2 MATERIALS A. Fiber cement panels manufactured from a pressed, stamped, and autoclaved mix of Portland cement, fly ash, silica, recycled rejects, and wood fiber bundles. B. Panel surface pre-finished and machine applied. C. AWP-1818 profiled along all four edges, such that both horizontal and vertical joints between the installed panels are ship-lapped. Project Name/Number/Date 07 42 43-5 Composite Wall Panels D. Factory-applied sealant gasket added to top and right panel edges; all AWP-1818 joints contain a factory sealant. 2.3 PERFORMANCE REQUIREMENTS: A. Fiber Cement Cladding – Must comply with ASTM C-1186, Type A, Grade II requirements: 1. Wet Flexural Strength: Result: 1418 psi, Lower Limit: 1015 psi. 2. Water Tightness: No water droplets observed on any specimen. 3. Freeze-thaw: No damage or defects observed. 4. Warm Water: No evidence of cracking, delamination, swelling, or other defects observed. 5. Heat-Rain: No crazing, cracking, or other deleterious effects, surface or joint changes observed in any specimen. B. Mean Coefficient of Linear Thermal Expansion (ASTM E-228): Max 1.0*10^-5 in./in. F. C. Surface Burning (CAN-ULC S102/ASTM E-84): Flame Spread: 0, Smoke Developed: 0. D. Wind Load (ASTM E-330): Contact manufacturer for ultimate test pressure data corresponding to framing type, dimensions, fastener type, and attachment clips. Project engineer(s) must determine Zone 4 and 5 design pressures based on project specifics. 1. Minimum lateral deflection: L/120. E. Water Penetration (ASTM E-331): No water leakage observed into wall cavity. F. Steady-State Heat Flux and Thermal Transmission Properties Test (ASTM C-518): 16mm thick panel thermal resistance R Value of 0.47. G. Fire Resistant (ASTM E-119): The wall assembly must successfully endure 60-minute fire exposure without developing excessive unexposed surface temperature or allowing flaming on the unexposed side of the assembly. H. Ignition Resistance (NFPA 268): No sustained flaming of panels, assembly when subjected to a minimum radiant heat flux of 12.5 kW/m2 ± 5% in the presence of a pilot ignition source for a 20-minute period. I. Fire Propagation (NFPA 285): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Commercial Wrap, ½” Densglass Gold Sheathing, 16” o.c. 18 gauge steel studs, mineral wool in-cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of NFPA 285. Project Name/Number/Date 07 42 43-6 Composite Wall Panels J. Fire Propagation (CAN/ULC S-134): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Housewrap, 5/8” FRT plywood, 16” o.c. 2x wood studs, fiberglass in- cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of CAN/ULC S-134. K. Drained and Back Ventilated Rainscreen (AAMA 509-14): System classifications: W1, V1. L. Florida Building Code - Test Protocol HVHZ (TAS 202, 203): Horizontal Application Design Pressure: 95 psf, Vertical Application Design Pressure: 85 psf. 2.4 INSTALLATION COMPONENTS A. Ultimate Clip System: 1. Starter Track: a. Horizontal Panel Installations - FA 700 – 3,030mm (l) galvalume coated steel. b. Vertical Panel Installations (AWP-3030 only) – FA 710T – 3,030mm (l) galvalume coated steel. 2. Panel Clips: JEL 778 “Ultimate Clip II” (10mm rainscreen for 16mm AWP) – Zinc- Aluminum-Magnesium alloy coated steel. a. Joint Tab Attachments (included) – used at all AWP-1818 panel to panel vertical joints. NOT used with AWP-3030 installations. 3. Corner Clips: JE 777C (10mm rainscreen for 5/8” AWP Manufactured Corners) -- Zinc-Aluminum-Magnesium alloy coated steel. 4. Single Flange Sealant Backer – FHK 1015 R (10mm) – 6.5’ (l) fluorine coated galvalume. 5. Double Flange Sealant Backer – FH 1015 R (10mm) – 10’ (l) fluorine coated galvalume. 6. Corrugated Spacer – FS 1005 (5mm), FS 1010 (10mm) – 4’ (l). B. Aluminum Trim (optional, see Section 2.1): Choose primed trim finish as specified in finish schedule. C. Essential Flashing System (optional, see Section 2.1): 1. Starter – main segments (3,030mm), inside corners, outside corners 2. Overhang – main segments (3,030mm), inside corners, outside corners, joint clips Project Name/Number/Date 07 42 43-7 Composite Wall Panels D. Fasteners: Corrosion resistant fasteners, such as hot-dipped galvanized screws appropriate to local building codes and practices must be used. Use Stainless Steel fasteners in high humidity and high-moisture regions. Panel manufacturer is not liable for corrosion resistance of fasteners. Do not use aluminum fasteners, staples or fasteners that are not rated or designed for intended use. See manufacturer’s instructions for appropriate fasteners for construction method used. E. Flashing: Flash all areas specified in manufacturer’s instructions. Do not use raw aluminum flashing. Flashing must be galvanized, anodized, or PVC coated. F. Sealant: Sealant shall comply with ASTM C920, Class 35. PART III: EXECUTION 3.1 EXAMINATION A. Verification of Conditions: 1. Fiber cement panels can be installed over braced wood, steel studs and sheathing including plywood, OSB, plastic foam (1” or less) or fiberboard sheathing. Fiber cement panels can also be installed over Structural Insulated Panels (SIP’s), Concrete Masonry Units (CMU’s) and Concrete Block Structures (CBS’s) with furring strips, and Pre- Engineered Metal Construction. Insulated Concrete Forms (ICFs) require added measures. Consult with Nichiha Technical Services. 2. Allowable stud spacing: 16” o.c. maximum. 3. A weather resistive barrier is required when installing fiber cement panels. Use an approved weather resistive barrier (WRB) as defined by the 2015 IBC or IRC. Refer to local building codes. 4. Appropriate metal flashing should be used to prevent moisture penetration around all doors, windows, wall bottoms, material transitions and penetrations. Refer to local building codes for best practices. B. Examine site to ensure substrate conditions are within alignment tolerances for proper installation. C. Do not begin installation until unacceptable conditions have been corrected. D. Do not install panels or components that appear to be damaged or defective. Do not install wet panels. Project Name/Number/Date 07 42 43-8 Composite Wall Panels 3.2 TOLERANCE A. Wall surface plane must be plumb and level within +/- ¼ inch in 20 feet in any direction. 1. One layer of Nichiha 5mm (~3/16”) Spacer may be used as shim. 3.3 INSTALLATION A. General: Install products in accordance with the latest installation guidelines of the manufacturer and all applicable building codes and other laws, rules, regulations and ordinances. Review all manufacturer installation, maintenance instructions, and other applicable documents before installation. 1. Consult with your local dealer or Nichiha Technical Department before installing any Nichiha fiber cement product on a building higher than 45 feet or three stories or for conditions not matching prescribed standard installation guide requirements and methods. A Technical Design Review (TDR) process is available to evaluate project feasibility. 2. Vertical Control/Expansion Joints are required with AWP-1818, for walls wider than 30 feet, within 2-12 feet of outside corners finished with metal trim and approximately every 30 feet thereafter. A. Vertical Control/Expansion Joints are required at each AWP-3030 vertical joint, or H-Mold trim may be used instead. 3. Horizontal/Compression Joints are required for multi-story installations of AWP. Locate joints at floor lines. Joints are flashed minimum ½” breaks. Do not caulk. Refer to installation guide(s). A. Wood framed buildings of three or more floors require a compression joint at each floor. B. Steel framed buildings (including reinforced concrete core with LGMF exterior walls) of more than three floors (or 45 feet) require a compression joint every 25 feet at a floor line. B. Panel Cutting 1. Always cut fiber cement panels outside or in a well ventilated area. Do not cut the products in an enclosed area. 2. Always wear safety glasses and NIOSH/OSHA approved respirator whenever cutting, drilling, sawing, sanding or abrading the products. Refer to manufacturer SDS for more information. 3. Use a dust-reducing circular saw with a diamond-tipped or carbide-tipped blade. Project Name/Number/Date 07 42 43-9 Composite Wall Panels a. Recommended circular saw: Makita 7-1/4” Circular Saw with Dust Collector (#5057KB). b. Recommended blade: Tenryu Board-Pro Plus PCD Blade (#BP-18505). c. Shears (electric or pneumatic) or jig saw can be used for complicated cuttings, such as service openings, curves, radii and scrollwork. 4. Silica Dust Warning: Fiber cement products may contain some amounts of crystalline silica, a naturally occurring, potentially hazardous mineral when airborne in dust form. Consult product SDS or visit https://www.osha.gov/dsg/topics/silicacrystalline/. 5. Immediately clean dust from cut panels as it may bind to the finish. 3.4 CLEANING AND MAINTENANCE A. Review manufacturer guidelines for detailed care instructions. Project Name/Number/Date 07 42 43-1 Composite Wall Panels Novenary Tile Three-Part Specification 07 42 43 Composite Wall Panels Part I - General 1.1 SECTION INCLUDES: A. Exterior, panelized fiber cement cladding system and accessories to complete a drained and back-ventilated rainscreen. B. Interior fiber cement panelized cladding system and accessories. 1.2 RELATED SECTIONS A. Section 05 41 00 - Structural Metal Stud Framing B. Section 06 10 00 - Rough Carpentry C. Section 06 16 00 - Sheathing D. Section 07 20 00 - Thermal Protection E. Section 07 25 00 - Weather Barriers F. Section 07 60 00 - Flashing and Sheet Metal G. Section 07 90 00 - Joint Protection 1.3 REFERENCES A. American Architectural Manufacturers Association (AAMA): 1. AAMA 509-14 – Voluntary Test and Classification Method of Drained and Back Ventilated Rain Screen Wall Cladding Systems B. ASTM International (ASTM): 1. ASTM C 518 - Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. 2. ASTM C 1185 - Standard Test Methods for Sampling and Testing Non-Asbestos Fiber Cement. a. ASTM C 1186 – Standard Specification for Flat Fiber-Cement Sheets. 3. ASTM E-84 - Standard Test for Surface Burning Characteristics of Building Materials. 4. ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials. 5. ASTM E 228 - Standard Test Method for Linear Thermal Expansion of Solid Materials with a Vitreous Silica Dilatometer. Project Name/Number/Date 07 42 43-2 Composite Wall Panels 6. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 7. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. C. Florida Building Code - Test Protocol HVHZ 1. Testing Application Standard (TAS) 202, 203 – HVHZ Test Procedures D. National Fire Protection Association (NFPA): 1. NFPA 285 - Fire Test Method for Exterior Wall Assemblies Containing Combustible Material. 2. NFPA 268 – Ignition Resistance of Exterior Wall Assemblies. E. Standards Council of Canada & Underwriters Laboratories Canada (ULC): 1. CAN/ULC S-102 – Standard Method of Test for Surface Burning Characteristics. 2. CAN/ULC S-134 – Standard Method of Fire Test of Exterior Wall Assembly. 1.4 SUBMITTALS A. Submit under provisions of Section 01 33 00. B. Product Data: Submit manufacturer’s product description, storage and handling requirements, and installation instructions. C. Product Test Reports and Code Compliance: Documents demonstrating product compliance with local building code, such as test reports or Evaluation Reports from qualified, independent testing agencies. D. LEED Credits: Provide documentation of LEED Credits for project certification under USGBC LEED 2009 (Version 3.0) or 2012 v.4. E. Manufacturer’s Details: Submit drawings (.dwg, .rvt, and/or .pdf formats), including plans, sections, showing installation details that demonstrate product dimensions, edge/termination conditions/treatments, compression and control joints, corners, openings, and penetrations. F. Samples: Submit samples of each product type proposed for use. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: 1. All fiber cement panels specified in this section must be supplied by a manufacturer with a minimum of 10 years of experience in fabricating and supplying fiber cement cladding systems. a. Products covered under this section are to be manufactured in an ISO 9001 certified facility. Project Name/Number/Date 07 42 43-3 Composite Wall Panels 2. Provide technical and design support as needed regarding installation requirements and warranty compliance provisions. B. Installer Qualifications: All products listed in this section are to be installed by a single installer trained by manufacturer or representative. C. Mock-Up Wall: Provide a mock-up wall as evaluation tool for product and installation workmanship. D. Pre-Installation Meetings: Prior to beginning installation, conduct conference to verify and discuss substrate conditions, manufacturer’s installation instructions and warranty requirements, and project requirements. 1.6 DELIVERY, STORAGE, AND HANDLING A. Panels must be stored flat and kept dry before installation. A waterproof cover over panels and accessories should be used at all times prior to installation. Do not stack pallets more than two high. Refer to the information included on each pallet. B. If panels are exposed to water or water vapor prior to installation, allow to completely dry before installing. Failure to do so may result in panel shrinkage at ship lap joints, and such action may void warranty. C. Panels MUST be carried on edge. Do not carry or lift panels flat. Improper handling may cause cracking or panel damage. D. Direct contact between the panels and the ground should be avoided at all times. It is necessary to keep panels clean during installation process. 1.7 WARRANTY A. Provide manufacturer’s 15-year warranty against manufactured defects in fiber cement panels. Additional 5-year extension available when refinished in year 14-15. B. Provide manufacturer’s 15-year warranty against manufactured defects in panel finish. C. Warranty provides for the original purchaser. See warranty for detailed information on terms, conditions and limitations. PART II: PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Nichiha Corporation, 18-19 Nishiki 2-chome Naka-ku, Nagoya, Aichi 460-8610, Japan. Project Name/Number/Date 07 42 43-4 Composite Wall Panels B. Acceptable Manufacturer’s Representative: Nichiha USA, Inc., 6465 E. Johns Crossing, Suite 250, Johns Creek, GA 30097. Toll free: 1.866.424.4421, Office: 770.805.9466, Fax: 770.805.9467, www.nichiha.com. 1. Basis of Design Product: Nichiha Novenary Tile. a. Profile colors: Clay, Ochre, Opal, Sand, and Slate. b. Profile: Nine rectangular blocks about 23-1/4” wide by 5-3/8” tall, separated by 5/8” wide and 3/8” deep grooves. c. Accessory/Component Options: i. Manufactured Corners with 3-1/2” returns for each profile color. ii. Aluminum trim options: J-Mold (MTJM21), Compression Joint (MTCJ21) 1. Finish: Pre-Matched to profile colors. iii. Essential Flashing System: Starter, Overhang. 1. Finish: Matte black. d. Dimensions – AWP-1818: 455mm (17-7/8”) (h) x 1,818 mm (71-9/16”) (l). e. Panel Thickness: 21 mm (7/8"). f. Finish: Matte, lightly textured. g. Weight: 47.8 lbs. per panel. h. Coverage: 8.88 sq. ft. per panel. i. Factory sealed on six [6] sides. C. Substitutions: Not permitted. D. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00. 2.2 MATERIALS A. Fiber cement panels manufactured from a pressed, stamped, and autoclaved mix of Portland cement, fly ash, silica, recycled rejects, and wood fiber bundles. B. Panel surface pre-finished and machine applied. C. Panels profiled along all four edges, such that both horizontal and vertical joints between the installed panels are ship-lapped. D. Factory-applied sealant gasket added to top and right panel edges; all joints contain a factory sealant. 2.3 PERFORMANCE REQUIREMENTS: A. Fiber Cement Cladding – Must comply with ASTM C-1186, Type A, Grade II requirements: Project Name/Number/Date 07 42 43-5 Composite Wall Panels 1. Wet Flexural Strength: Result: 1418 psi, Lower Limit: 1015 psi. 2. Water Tightness: No water droplets observed on any specimen. 3. Freeze-thaw: No damage or defects observed. 4. Warm Water: No evidence of cracking, delamination, swelling, or other defects observed. 5. Heat-Rain: No crazing, cracking, or other deleterious effects, surface or joint changes observed in any specimen. B. Mean Coefficient of Linear Thermal Expansion (ASTM E-228): Max 1.0*10^-5 in./in. F. C. Surface Burning (CAN-ULC S102/ASTM E-84): Flame Spread: 0, Smoke Developed: 0. D. Wind Load (ASTM E-330): Contact manufacturer for ultimate test pressure data corresponding to framing type, dimensions, fastener type, and attachment clips. Project engineer(s) must determine Zone 4 and 5 design pressures based on project specifics. 1. Minimum lateral deflection: L/120. E. Water Penetration (ASTM E-331): No water leakage observed into wall cavity. F. Steady-State Heat Flux and Thermal Transmission Properties Test (ASTM C-518): 16mm thick panel thermal resistance R Value of 0.47. G. Fire Resistant (ASTM E-119): The wall assembly must successfully endure 60-minute fire exposure without developing excessive unexposed surface temperature or allowing flaming on the unexposed side of the assembly. H. Ignition Resistance (NFPA 268): No sustained flaming of panels, assembly when subjected to a minimum radiant heat flux of 12.5 kW/m2 ± 5% in the presence of a pilot ignition source for a 20-minute period. I. Fire Propagation (NFPA 285): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Commercial Wrap, ½” Densglass Gold Sheathing, 16” o.c. 18 gauge steel studs, mineral wool in-cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of NFPA 285. J. Fire Propagation (CAN/ULC S-134): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Housewrap, 5/8” FRT plywood, 16” o.c. 2x wood studs, fiberglass in- cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of CAN/ULC S-134. K. Drained and Back Ventilated Rainscreen (AAMA 509-14): System classifications: W1, V1. L. Florida Building Code - Test Protocol HVHZ (TAS 202, 203): Design Pressure: 95 psf. Project Name/Number/Date 07 42 43-6 Composite Wall Panels 2.4 INSTALLATION COMPONENTS A. Ultimate Clip System: 1. Starter Track: FA 700 (10mm rainscreen) – 10’ (3030mm) (l) galvalume coated steel. 2. Panel Clips: JEL 778 “Ultimate Clip II” (10mm rainscreen for 5/8” AWP) – Zinc- Aluminum-Magnesium alloy coated steel. a. Joint Tab Attachments (included) – used at all AWP-1818 panel to panel vertical joints. 3. Corner Clips: JE 777C (10mm rainscreen for 5/8” AWP Manufactured Corners) -- Zinc-Aluminum-Magnesium alloy coated steel. 4. Single Flange Sealant Backer – FHK 1015 R (10mm) – 6.5’ (l) fluorine coated galvalume. 5. Double Flange Sealant Backer – FH 1015 R (10mm) – 10’ (l) fluorine coated galvalume. 6. Corrugated Spacer – FS 1005 (5mm), FS 1010 (10mm) – 4’ (l). B. Aluminum Trim (optional): J-Mold and Compression Joint Flashing available for 21-mm thick panels. C. Essential Flashing System (optional): 1. Starter – main segments (3030mm), inside corners, outside corners 2. Overhang – main segments (3030mm), inside corners, outside corners, joint clips D. Fasteners: Corrosion resistant fasteners, such as hot-dipped galvanized screws appropriate to local building codes and practices must be used. Use Stainless Steel fasteners in high humidity and high-moisture regions. Panel manufacturer is not liable for corrosion resistance of fasteners. Do not use aluminum fasteners, staples or fasteners that are not rated or designed for intended use. See manufacturer’s instructions for appropriate fasteners for construction method used. E. Flashing: Flash all areas specified in manufacturer’s instructions. Do not use raw aluminum flashing. Flashing must be galvanized, anodized, or PVC coated. F. Sealant: Sealant shall comply with ASTM C920, Class 35. PART III: EXECUTION 3.1 EXAMINATION A. Verification of Conditions: Project Name/Number/Date 07 42 43-7 Composite Wall Panels 1. Fiber cement panels can be installed over braced wood, steel studs and sheathing including plywood, OSB, plastic foam (1” or less) or fiberboard sheathing. Fiber cement panels can also be installed over Structural Insulated Panels (SIP’s), Concrete Masonry Units (CMU’s) and Concrete Block Structures (CBS’s) with furring strips, and Pre- Engineered Metal Construction. Insulated Concrete Forms (ICFs) require added measures. Consult with Nichiha Technical Services. 2. Allowable stud spacing: 16” o.c. maximum. 3. A weather resistive barrier is required when installing fiber cement panels. Use an approved weather resistive barrier (WRB) as defined by the 2015 IBC or IRC. Refer to local building codes. 4. Appropriate metal flashing should be used to prevent moisture penetration around all doors, windows, wall bottoms, material transitions and penetrations. Refer to local building codes for best practices. B. Examine site to ensure substrate conditions are within alignment tolerances for proper installation. C. Do not begin installation until unacceptable conditions have been corrected. D. Do not install panels or components that appear to be damaged or defective. Do not install wet panels. 3.2 TOLERANCE A. Wall surface plane must be plumb and level within +/- ¼ inch in 20 feet in any direction. 1. One layer of Nichiha 5mm (~3/16”) Spacer may be used as shim. 3.3 INSTALLATION A. General: Install products in accordance with the latest installation guidelines of the manufacturer and all applicable building codes and other laws, rules, regulations and ordinances. Review all manufacturer installation, maintenance instructions, and other applicable documents before installation. 1. Consult with your local dealer or Nichiha Technical Department before installing any Nichiha fiber cement product on a building higher than 45 feet or three stories or for conditions not matching prescribed standard installation guide requirements and methods. A Technical Design Review (TDR) process is available to evaluate project feasibility. 2. Vertical Control/Expansion Joints are required, for walls wider than 30 feet, within 2-12 feet of outside corners finished with metal trim and approximately every 30 feet thereafter. Project Name/Number/Date 07 42 43-8 Composite Wall Panels 3. Horizontal/Compression Joints are required for multi-story installations of AWP. Locate joints at floor lines. Joints are flashed minimum ½” breaks. Do not caulk. Refer to installation guide(s). A. Wood framed buildings of three or more floors require a compression joint at each floor. B. Steel framed buildings (including reinforced concrete core with LGMF exterior walls) of more than three floors (or 45 feet) require a compression joint every 25 feet at a floor line. B. Panel Cutting 1. Always cut fiber cement panels outside or in a well ventilated area. Do not cut the products in an enclosed area. 2. Always wear safety glasses and NIOSH/OSHA approved respirator whenever cutting, drilling, sawing, sanding or abrading the products. Refer to manufacturer SDS for more information. 3. Use a dust-reducing circular saw with a diamond-tipped or carbide-tipped blade. a. Recommended circular saw: Makita 7-1/4” Circular Saw with Dust Collector (#5057KB). b. Recommended blade: Tenryu Board-Pro Plus PCD Blade (#BP-18505). c. Shears (electric or pneumatic) or jig saw can be used for complicated cuttings, such as service openings, curves, radii and scrollwork. 4. Silica Dust Warning: Fiber cement products may contain some amounts of crystalline silica, a naturally occurring, potentially hazardous mineral when airborne in dust form. Consult product SDS or visit https://www.osha.gov/dsg/topics/silicacrystalline/. 5. Immediately clean dust from cut panels as it may bind to the finish. 3.4 CLEANING AND MAINTENANCE A. Review manufacturer guidelines for detailed care instructions. Project Name/Number/Date 07 42 43-1 Composite Wall Panels Ribbed Three-Part Specification 07 42 43 Composite Wall Panels Part I - General 1.1 SECTION INCLUDES: A. Exterior, panelized fiber cement cladding system and accessories to complete a drained and back-ventilated rainscreen. B. Interior fiber cement panelized cladding system and accessories. 1.2 RELATED SECTIONS A. Section 05 41 00 - Structural Metal Stud Framing B. Section 06 10 00 - Rough Carpentry C. Section 06 16 00 - Sheathing D. Section 07 20 00 - Thermal Protection E. Section 07 25 00 - Weather Barriers F. Section 07 60 00 - Flashing and Sheet Metal G. Section 07 90 00 - Joint Protection 1.3 REFERENCES A. American Architectural Manufacturers Association (AAMA): 1. AAMA 509-14 – Voluntary Test and Classification Method of Drained and Back Ventilated Rain Screen Wall Cladding Systems B. ASTM International (ASTM): 1. ASTM C 518 - Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus. 2. ASTM C 1185 - Standard Test Methods for Sampling and Testing Non-Asbestos Fiber Cement. a. ASTM C 1186 – Standard Specification for Flat Fiber-Cement Sheets. 3. ASTM E-84 - Standard Test for Surface Burning Characteristics of Building Materials. 4. ASTM E 119 - Standard Test Methods for Fire Tests of Building Construction and Materials. 5. ASTM E 228 - Standard Test Method for Linear Thermal Expansion of Solid Materials with a Vitreous Silica Dilatometer. Project Name/Number/Date 07 42 43-2 Composite Wall Panels 6. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 7. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. C. Florida Building Code - Test Protocol HVHZ 1. Testing Application Standard (TAS) 202, 203 – HVHZ Test Procedures D. National Fire Protection Association (NFPA): 1. NFPA 285 - Fire Test Method for Exterior Wall Assemblies Containing Combustible Material. 2. NFPA 268 – Ignition Resistance of Exterior Wall Assemblies. E. Standards Council of Canada & Underwriters Laboratories Canada (ULC): 1. CAN/ULC S-102 – Standard Method of Test for Surface Burning Characteristics. 2. CAN/ULC S-134 – Standard Method of Fire Test of Exterior Wall Assembly. 1.4 SUBMITTALS A. Submit under provisions of Section 01 33 00. B. Product Data: Submit manufacturer’s product description, storage and handling requirements, and installation instructions. C. Product Test Reports and Code Compliance: Documents demonstrating product compliance with local building code, such as test reports or Evaluation Reports from qualified, independent testing agencies. D. LEED Credits: Provide documentation of LEED Credits for project certification under USGBC LEED 2009 (Version 3.0) or 2012 v.4. E. Manufacturer’s Details: Submit drawings (.dwg, .rvt, and/or .pdf formats), including plans, sections, showing installation details that demonstrate product dimensions, edge/termination conditions/treatments, compression and control joints, corners, openings, and penetrations. F. Samples: Submit samples of each product type proposed for use. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: 1. All fiber cement panels specified in this section must be supplied by a manufacturer with a minimum of 10 years of experience in fabricating and supplying fiber cement cladding systems. a. Products covered under this section are to be manufactured in an ISO 9001 certified facility. Project Name/Number/Date 07 42 43-3 Composite Wall Panels 2. Provide technical and design support as needed regarding installation requirements and warranty compliance provisions. B. Installer Qualifications: All products listed in this section are to be installed by a single installer trained by manufacturer or representative. C. Mock-Up Wall: Provide a mock-up wall as evaluation tool for product and installation workmanship. D. Pre-Installation Meetings: Prior to beginning installation, conduct conference to verify and discuss substrate conditions, manufacturer’s installation instructions and warranty requirements, and project requirements. 1.6 DELIVERY, STORAGE, AND HANDLING A. Panels must be stored flat and kept dry before installation. A waterproof cover over panels and accessories should be used at all times prior to installation. Do not stack pallets more than two high. Refer to the information included on each pallet. B. If panels are exposed to water or water vapor prior to installation, allow to completely dry before installing. Failure to do so may result in panel shrinkage at ship lap joints, and such action may void warranty. C. Panels MUST be carried on edge. Do not carry or lift panels flat. Improper handling may cause cracking or panel damage. D. Direct contact between the panels and the ground should be avoided at all times. It is necessary to keep panels clean during installation process. 1.7 WARRANTY A. Provide manufacturer’s 15-year warranty against manufactured defects in fiber cement panels. Additional 5-year extension available when refinished in year 14-15. B. Provide manufacturer’s 15-year warranty against manufactured defects in panel finish. C. Warranty provides for the original purchaser. See warranty for detailed information on terms, conditions and limitations. PART II: PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Nichiha Corporation, 18-19 Nishiki 2-chome Naka-ku, Nagoya, Aichi 460-8610, Japan. Project Name/Number/Date 07 42 43-4 Composite Wall Panels B. Acceptable Manufacturer’s Representative: Nichiha USA, Inc., 6465 E. Johns Crossing, Suite 250, Johns Creek, GA 30097. Toll free: 1.866.424.4421, Office: 770.805.9466, Fax: 770.805.9467, www.nichiha.com. 1. Basis of Design Product: Nichiha Ribbed. a. Profile colors: Indigo, Ivory, or designer-specified custom color. b. Profile: Each panel has nine (35mm) ribs with chamfered edges, spaced with 10mm grooves between. c. Finish: Moderately textured ribs. Grooves are smooth. d. Accessory/Component Options: i. Manufactured Corners with 3-1/2” returns for each profile color. ii. Aluminum trim options: Corner Key, Open Outside Corner, H-Mold, J-Mold, Compression Joint, Inside Corner 1. Finish: Custom Color, Clear Anodized, or Primed iii. Essential Flashing System: Starter, Overhang. 1. Finish: Matte black. e. Dimensions - AWP-3030: 455mm (17-7/8”) (h) x 3,030 mm (119-5/16”) (l). f. Panel Thickness: 16 mm (5/8"). g. Weight: 57.32 lbs. per panel. h. Coverage: 14.81 sq. ft. per panel. i. Factory sealed on six [6] sides. C. Substitutions: Not permitted. D. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00. 2.2 MATERIALS A. Fiber cement panels manufactured from a pressed, stamped, and autoclaved mix of Portland cement, fly ash, silica, recycled rejects, and wood fiber bundles. B. Panel surface pre-finished and machine applied. C. Panels profiled along 3030mm edges so that the long joints between the installed panels are ship-lapped. D. Factory-applied sealant gasket added to top panel edge; all 3030mm edge joints contain a factory sealant. 2.3 PERFORMANCE REQUIREMENTS: A. Fiber Cement Cladding – Must comply with ASTM C-1186, Type A, Grade II requirements: Project Name/Number/Date 07 42 43-5 Composite Wall Panels 1. Wet Flexural Strength: Result: 1418 psi, Lower Limit: 1015 psi. 2. Water Tightness: No water droplets observed on any specimen. 3. Freeze-thaw: No damage or defects observed. 4. Warm Water: No evidence of cracking, delamination, swelling, or other defects observed. 5. Heat-Rain: No crazing, cracking, or other deleterious effects, surface or joint changes observed in any specimen. B. Mean Coefficient of Linear Thermal Expansion (ASTM E-228): Max 1.0*10^-5 in./in. F. C. Surface Burning (CAN-ULC S102/ASTM E-84): Flame Spread: 0, Smoke Developed: 0. D. Wind Load (ASTM E-330): Contact manufacturer for ultimate test pressure data corresponding to framing type, dimensions, fastener type, and attachment clips. Project engineer(s) must determine Zone 4 and 5 design pressures based on project specifics. 1. Minimum lateral deflection: L/120. E. Water Penetration (ASTM E-331): No water leakage observed into wall cavity. F. Steady-State Heat Flux and Thermal Transmission Properties Test (ASTM C-518): 16mm thick panel thermal resistance R Value of 0.47. G. Fire Resistant (ASTM E-119): The wall assembly must successfully endure 60-minute fire exposure without developing excessive unexposed surface temperature or allowing flaming on the unexposed side of the assembly. H. Ignition Resistance (NFPA 268): No sustained flaming of panels, assembly when subjected to a minimum radiant heat flux of 12.5 kW/m2 ± 5% in the presence of a pilot ignition source for a 20-minute period. I. Fire Propagation (NFPA 285): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Commercial Wrap, ½” Densglass Gold Sheathing, 16” o.c. 18 gauge steel studs, mineral wool in-cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of NFPA 285. J. Fire Propagation (CAN/ULC S-134): Wall assembly of Nichiha AWP, Ultimate Clips and Starter Track, Tyvek Housewrap, 5/8” FRT plywood, 16” o.c. 2x wood studs, fiberglass in- cavity insulation, and interior 5/8” Type X gypsum met the acceptance criteria of CAN/ULC S-134. K. Drained and Back Ventilated Rainscreen (AAMA 509-14): System classifications: W1, V1. L. Florida Building Code - Test Protocol HVHZ (TAS 202, 203): Horizontal Application Design Pressure: 95 psf, Vertical Application Design Pressure: 85 psf. Project Name/Number/Date 07 42 43-6 Composite Wall Panels 2.4 INSTALLATION COMPONENTS A. Ultimate Clip System: 1. Starter Track: a. Horizontal Panel Installations - FA 700 – 3,030mm (l) galvalume coated steel. b. Vertical Panel Installations (AWP-3030 only) – FA 710T – 3,030mm (l) galvalume coated steel. 2. Panel Clips: JEL 778 “Ultimate Clip II” (10mm rainscreen for 16mm AWP) – Zinc- Aluminum-Magnesium alloy coated steel. a. Joint Tab Attachments (included) – used at all AWP-1818 panel to panel vertical joints – NOT used with AWP-3030 installations. 3. Corner Clips: JE 777C (10mm rainscreen for 5/8” AWP Manufactured Corners) -- Zinc-Aluminum-Magnesium alloy coated steel. 4. Single Flange Sealant Backer – FHK 1015 R (10mm) – 6.5’ (l) fluorine coated galvalume. 5. Double Flange Sealant Backer – FH 1015 R (10mm) – 10’ (l) fluorine coated galvalume. 6. Corrugated Spacer – FS 1005 (5mm), FS 1010 (10mm) – 4’ (l). B. Aluminum Trim (optional): Paint primed trim as specified in finish schedule. C. Essential Flashing System (optional): 1. Starter – main segments (3,030mm), inside corners, outside corners 2. Overhang – main segments (3,030mm), inside corners, outside corners, joint clips D. Fasteners: Corrosion resistant fasteners, such as hot-dipped galvanized screws appropriate to local building codes and practices must be used. Use Stainless Steel fasteners in high humidity and high-moisture regions. Panel manufacturer is not liable for corrosion resistance of fasteners. Do not use aluminum fasteners, staples or fasteners that are not rated or designed for intended use. See manufacturer’s instructions for appropriate fasteners for construction method used. E. Flashing: Flash all areas specified in manufacturer’s instructions. Do not use raw aluminum flashing. Flashing must be galvanized, anodized, or PVC coated. F. Sealant: Sealant shall comply with ASTM C920, Class 35. Project Name/Number/Date 07 42 43-7 Composite Wall Panels PART III: EXECUTION 3.1 EXAMINATION A. Verification of Conditions: 1. Fiber cement panels can be installed over braced wood, steel studs and sheathing including plywood, OSB, plastic foam (1” or less) or fiberboard sheathing. Fiber cement panels can also be installed over Structural Insulated Panels (SIP’s), Concrete Masonry Units (CMU’s) and Concrete Block Structures (CBS’s) with furring strips, and Pre- Engineered Metal Construction. Insulated Concrete Forms (ICFs) require added measures. Consult with Nichiha Technical Services. 2. Allowable stud spacing: 16” o.c. maximum. 3. A weather resistive barrier is required when installing fiber cement panels. Use an approved weather resistive barrier (WRB) as defined by the 2015 IBC or IRC. Refer to local building codes. 4. Appropriate metal flashing should be used to prevent moisture penetration around all doors, windows, wall bottoms, material transitions and penetrations. Refer to local building codes for best practices. B. Examine site to ensure substrate conditions are within alignment tolerances for proper installation. C. Do not begin installation until unacceptable conditions have been corrected. D. Do not install panels or components that appear to be damaged or defective. Do not install wet panels. 3.2 TOLERANCE A. Wall surface plane must be plumb and level within +/- ¼ inch in 20 feet in any direction. 1. One layer of Nichiha 5mm (~3/16”) Spacer may be used as shim. 3.3 INSTALLATION A. General: Install products in accordance with the latest installation guidelines of the manufacturer and all applicable building codes and other laws, rules, regulations and ordinances. Review all manufacturer installation, maintenance instructions, and other applicable documents before installation. 1. Consult with your local dealer or Nichiha Technical Department before installing any Nichiha fiber cement product on a building higher than 45 feet or three stories or for conditions not matching prescribed standard installation guide requirements and Project Name/Number/Date 07 42 43-8 Composite Wall Panels methods. A Technical Design Review (TDR) process is available to evaluate project feasibility. 2. Vertical Control/Expansion Joints are required at each AWP-3030 vertical joint, or H-Mold trim may be used instead. 3. Horizontal/Compression Joints are required for multi-story installations of AWP. Locate joints at floor lines. Joints are flashed minimum ½” breaks. Do not caulk. Refer to installation guide(s). A. Wood framed buildings of three or more floors require a compression joint at each floor. B. Steel framed buildings (including reinforced concrete core with LGMF exterior walls) of more than three floors (or 45 feet) require a compression joint every 25 feet at a floor line. B. Panel Cutting 1. Always cut fiber cement panels outside or in a well ventilated area. Do not cut the products in an enclosed area. 2. Always wear safety glasses and NIOSH/OSHA approved respirator whenever cutting, drilling, sawing, sanding or abrading the products. Refer to manufacturer SDS for more information. 3. Use a dust-reducing circular saw with a diamond-tipped or carbide-tipped blade. a. Recommended circular saw: Makita 7-1/4” Circular Saw with Dust Collector (#5057KB). b. Recommended blade: Tenryu Board-Pro Plus PCD Blade (#BP-18505). c. Shears (electric or pneumatic) or jig saw can be used for complicated cuttings, such as service openings, curves, radii and scrollwork. 4. Silica Dust Warning: Fiber cement products may contain some amounts of crystalline silica, a naturally occurring, potentially hazardous mineral when airborne in dust form. Consult product SDS or visit https://www.osha.gov/dsg/topics/silicacrystalline/. 5. Immediately clean dust from cut panels as it may bind to the finish. 3.4 CLEANING AND MAINTENANCE A. Review manufacturer guidelines for detailed care instructions.