Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20260543 100 Union Ave Exterior Modification- PV Array
Revised 01/2021 APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person: Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use: Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? No Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ installed a 3.90kW roof mounted PV array. **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 Request for extension of current approval Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure (4 units +) -Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? No Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: See Attached Revised 01/2021 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 6 ny-sun.ny.gov for Energy New York State Unified Solar Permit Expedited Solar Permit Process for Small-Scale Roof-Mounted Residential and Commercial Solar Electric Requirements for Application Submittal – Part A For use in all New York State counties with the exception of Nassau County and Suffolk County. The expedited solar permitting process uses a unified permit across participating municipalities in New York State. A combined building and electrical permit for a grid‐tied solar electric system will be issued pending proper completion of forms, submission of approved plans and approval by municipality. All applicants must submit: 1.Unified Solar Permit for Small-Scale Solar Electric Systems Eligibility Checklist – PART B 2.One (1) set of plans that include: •Site Plan showing location of major components of solar system and other equipment on roof or legal accessory structure. This plan should represent relative location of components at site, including, but not limited to, location of array, existing electrical service location, utility meter, inverter location, system orientation and tilt angle. This plan should show access and pathways that are compliant with New York State Fire Code, if applicable. •One‐Line or 3‐Line Electrical Diagram. The electric diagram required by NYSERDA for an incentive application and/or utility for an interconnection agreement can be used here. •Specification Sheets for all manufactured components. If these sheets are available electronically, a web address will be accepted in place of an attachment, at the discretion of the municipality. •All diagrams and plans must be prepared by a PE or RA as required by New York State law and include the following: (a)Project address, section, block and lot number of the property; (b) Owner’s name, address and phone number; (c)Name, address and phone number of the person preparing the plans; and (d) System capacity in kW‐DC. 3.Unified Solar Permit for Small-Scale Solar Electric Systems Application – PART C 4.Permit Fee Amount : Base fee of $150.00 for residential or $330.00 for commercial, check made payable to Commissioner of Finance. A fee of $.25 per square foot for residential or $.30 per square foot for commercial will be calculated by inspector during review. Permit Review and Inspection Timeline Permit determinations will be issued within 14 calendar days upon receipt of complete and accurate applications. The municipality will provide feedback within 7 calendar days of receiving incomplete or inaccurate applications. If an inspection is required, a single inspection should be sufficient and will be provided within 7 calendar days of inspection request. The NY-Sun Initiative, a dynamic public-private partnership, will drive growth of the solar industry and make solar technology more affordable for all New Yorkers. Visit ny-sun.ny.gov for more information on the NY-Sun initiative. CITY OF SARATOGA SPRINGS BUILDING DEPARTMENT City Hall - 474 Broadway Saratoga Springs, NY 12866 Telephone (518) 587-3550 Ext. 2511 Fax (518) 580-9480 FOR OFFICE USE ONLY: ZONING DISTRICT:_______________ PERMIT TYPE: RES____ COMM____ FILE #:___________________________ APPLICATION #:__________________ DATE APPLIED:__________________ PERMIT #: _______________________ ISSUE/DENY DATE:_______________ ISSUED BY:______________________ APPLICATION FEE PAID:__________ INSURANCE CERTIFICATES: LB WC DB ny-sun.ny.gov for Energy Eligibility Checklist – Part B To determine if you are eligible for the expedited permitting process, answer the questions below. Yes No 1. Solar installation has a rated capacity of 12 kW or less. Yes No 2. Solar installation is not subject to review by an Architectural or Historical Review Board. Yes No 3. Solar installation does not need a zoning variance or special use permit/conditional use permit. Yes No 4. Solar installation is to be mounted on a permitted roof structure of a building, or on a legal accessory structure. If on a legal accessory structure, a diagram showing existing electrical connection to structure is attached. Yes No 5. Solar installation is compliant with all applicable electrical and building codes. Yes No 6. Solar installation is compliant with New York State Fire Code. Yes No 7. The Solar Installation Contractor complies with all licensing and other requirements of the jurisdiction and the State. Yes No 8. The proposed equipment is permitted by code and equipment meets all relevant certification standards. Yes No 9. The solar electric system and all components will be installed per the manufacturer’s specifications. Yes No 10. The project will comply with adopted National Electrical Code® requirements. Yes No 11. The roof has no more than a single layer of roof covering (in addition to the solar equipment). Yes No 12. The system is to be mounted parallel to the roof surface, or tilted with no more than an 18 inch gap between the module frame and the roof surface. Yes No 13. The system will have a distributed weight of less than 5 pounds per square foot and less than 45 pounds per attachment point to roof. If you answered “No” to any of Questions 1‐10, you are not eligible to participate in the expedited permitting process and must go through the standard permitting process dictated by the municipality. If you answered “No” to any of Questions 11‐13, in order to use this form, in addition to other New York State PE or RA requirements, you must provide a letter from a Professional Engineer or Registered Architect certifying that the existing structure can support the additional weight and wind loads of the solar electric system. If you answered “Yes” to all of the above questions, please sign below to affirm that all answers are correct, and you have met all the conditions and requirements to participate in this expedited process. Property Owner’s Signature Date Solar Installation Contractor Signature Date The NY-Sun Initiative, a dynamic public-private partnership, will drive growth of the solar industry and make solar technology more affordable for all New Yorkers. Visit ny-sun.ny.gov for more information on the NY-Sun initiative. for Energy ny-sun.ny.gov taller Business Name Application – Part C 1.Property Owner: Property Owner’s Name Phone Email Property Address Section Block Lot Number 2.Existing Use: Single Family 2‐4 Family Commercial Other 3.Provide the total system capacity rating (sum of all panels) Solar Electric System: kW‐DC 4.Solar Installation Contractor and Electrician: Ins Installer Business Address Installer Contact Name Installer Phone Number Installer License Number(s) Installer Email Electrician Business Name Electrician License Number 5.What is the existing roofing material? 6.Provide method and type of weatherproofing for roof penetrations (i.e., flashing, caulk). 7.Is the mounting structure an engineered product designed to mount solar electric modules?Yes No If no, provide details of structural attachment in a letter certified by a design professional. continued > The NY-Sun Initiative, a dynamic public-private partnership, will drive growth of the solar industry and make solar technology more affordable for all New Yorkers. Visit ny-sun.ny.gov for more information on the NY-Sun initiative. ny-sun.ny.gov Application – Part C (continued) for Energy GEN-NYSUN-uspi-form-1-v3 10/14 8.For manufactured mounting systems, provide the following information about the mounting system: a. Mounting System Manufacturer b.Product Name and Model Number c.Total Weight of Solar Electric Modules and Rails _lbs. d.Total Number of Attachment Points e.Weight per Attachment Point (c ÷ d)lbs. f.Maximum Spacing Between Attachment Points on a Rail inches (see product manual for maximum spacing allowed based on maximum design wind speed) g.Total Surface Area of Solar Electric Modules (square feet)ft2 h. Distributed Weight of Solar Electric Module on Roof (c ÷ g)lbs./ft2 9.Indicate quantity, brand, make and model of the: Inverter(s): ____________ ________________________ ______________________________________________ Quantity Make Model Modules: ____________ ________________________ ______________________________________________ Quantity Make Model Please sign below to affirm that all answers are correct and that you have met all the conditions and requirements to participate in this expedited process. Property Owner’s Signature Date Solar Installation Contractor Signature Date The NY-Sun Initiative, a dynamic public-private partnership, will drive growth of the solar industry and make solar technology more affordable for all New Yorkers. Visit ny-sun.ny.gov for more information on the NY-Sun initiative. 1 BUILDING PERMIT SUBMISSION CHECKLIST ROOF MOUNTED SOLAR PANELS RESIDENTIAL AND COMMERCIAL PROJECT SITE ADDRESS____________________________ ZONING DISTRICT____________________________ CHECKLIST PREPARED BY:__________________________ PREPARER’S PHONE NO.:______________________ ALL ITEMS BELOW MUST BE CHECKED EITHER “YES”, “NO” or “N/A. A separate checklist, must accompany each application for a building permit. All items checked “YES” shall accompany the application form at the time of submission to the building department. Until the application is deemed complete it may be rejected by the building department and returned to the applicant. Acceptance of a permit submission as complete does not imply or guarantee that a permit will be issued. YES NO N/A 1.Building permit form completed including all required signatures. 2.Base fee of $125.00 for residential or $175.00 for commercial, check made payable to Commissioner of Finance. A fee of $.20 per square foot for residential or $.25 per square foot for commercial will be calculated by inspector during review. 3.Home Owners Association approval. 4.All required Land Use Board approvals (if applicable). 5.Engineer’s letter certifying that the roof can hold the weight of the so lar panels. 6.Site Plan showing location of major components of solar system and other equipment on roof or legal accessory structure. 7.One Line or 3-Line Electrical Diagram. 8.Specification sheet of all manufactured components. 9.For the Certificate of Occupancy: Proof of Electrical Inspection, Letter certifying that the panels were installed per the manufacturers’ recommendations. 10.All required Insurance certificates: General Liability, Workers Compensation (form C105.2) and Disability (form DB120.1). 11.Additional information may be required by the reviewing inspector as deemed neces sary. FOR STAFF USE ONLY: HISTORIC REVIEW DISTRICT YES NO ARCHITECTURAL REVIEW DISTRICT YES NO ZONING VARIANCE YES NO ***** Application will not be accepted if required Land Use Board approvals have not be en obtained ***** SUBMISSION ACCEPTED FOR REVIEW DATE______________ TIME_______________ REVIEWED BY (SIGNATURE) _________________________________________________________ 2 The Individual filing this application, to the fullest extent provided by law, shall indemnify and save harmless the City of Saratoga Springs, its Agents and Employees (hereinafter referred to as “City”), from and against all claims, damages, losses and expense (including, but not limited to, attorneys’ fees), arising out of or resu lting from the performance of the work covered by this building permit application, sustained by any person or persons, provided that any such claim, damage, loss or expense is attributable to bodily injury, sickness, disease, or death, or to injury to or destruction of property caused by the tortious act or negligent act or omission of Applicant, its contractor or its employees or anyone for whom the Contractor is legally liable or Subcontractors. _______ (initial) Please note that all applications granted approval by the Design Review Commission and/or the Zoning Board of Appeals shall expire within eighteen months unless a building permit is issued and actual construction has begun (section 240-7.12) Application is hereby made to the Building Department for the issuance of a building permit for construction as herein described, pursuant to provisions of the Zoning Ordinance of the City of Saratoga Springs and in accordance with the N.Y. State Uniform Fire Prevention and Building Code which is applicable to new construction of buildings, and to conversions, additions and alterations to buildings. The owner and the applicant agree to comply with all applicable laws, ordinances and regulations and with all regulations and procedures as explained in this application, and will allow all inspectors to enter the premises for all required and necessary inspections. The following regulations shall apply: A.This application shall be completed including all required signatures. B.Insurance requirements: If homeowner is acting as general contractor: see Homeowners Insurance Requirements (attached) and Affidavit of Exemption of Workers Compensation. (Form BP-1, found on our website) If using a contractor, contractor must provide: (a) certificate of liability insurance showing a one million dollars per occurrence and two million dollars aggregate, with the City of Saratoga Springs listed as additional insured and certificate holder; (b) certificate of workers compensation insurance, on either the State approved C-105.2 form or the U-26.3 form; (c) certificate of disability insurance, on either the State approved DB-120.1 or DB-155 form; (d) If needed, Form CE-200 for WC/DB exemption is found at www.wcb.ny.gov. C.Application fee as required by the City Code and as calculated by the building department, shall be paid by check or money order (payable to “Commissioner of Finance”.) Base Fee $125.00 plus $.20/sf for residential or $175.00 plus $.25/sf for commercial. D.Work covered by this application shall not commence prior to permit issuance. E.Any deviation from approved plans must be authorized by the approval of revised plans subject to the same procedure established for the examination of the original plans by the building department, including any required fees. F.Building Department shall be notified (minimum notice – 24 hours in advance) according to this required schedule of inspections. (Note; before subsequent inspection requests will be scheduled, all prior inspections shall have passed). See attached card for required inspections included with building permit when issued. G.The building permit is effective for two years from the date of issuance unless a different period of time is specified. 464740969^ ^ ^ ^ ^ ^ LOVELL SAFETY MGMT CO., LLC 22 CORTLANDT STREET 33RD FLR NEW YORK NY 10007 | nysif.com PO Box 66699, Albany, NY 12206 KASSELMAN SOLAR LLC 279 BROADWAY, STE 2 MENANDS NY 12204 POLICYHOLDER CITY OF SARATOGA SPRINGS 474 BROADWAY SARATOGA SPRINGS NY 12866 CERTIFICATE HOLDER POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2329 433-3 729003 04/01/2026 TO 04/01/2027 03/10/2026 SCAN TO VALIDATE AND SUBSCRIBE THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2329 433-3, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP. THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR, PARTNERS AND/OR MEMBERS OF A LIMITED LIABILITY COMPANY. THE POLICY INCLUDES A WAIVER OF SUBROGATION ENDORSEMENT UNDER WHICH NYSIF AGREES TO WAIVE ITS RIGHT OF SUBROGATION TO BRING AN ACTION AGAINST THE CERTIFICATE HOLDER TO RECOVER AMOUNTS WE PAID IN WORKERS' COMPENSATION AND/OR MEDICAL BENEFITS TO OR ON BEHALF OF AN EMPLOYEE OF OUR INSURED IN THE EVENT THAT, PRIOR TO THE DATE OF THE ACCIDENT, THE CERTIFICATE HOLDER HAS ENTERED INTO A WRITTEN CONTRACT WITH OUR INSURED THAT REQUIRES THAT SUCH RIGHT OF SUBROGATION BE WAIVED. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR, INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 530042145 U-26.3Form WC-CERT-NOPRINT Version 3 (08/29/2019) [WC Policy-23294333] 00000000000148791171 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 235 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 3/25/2026 Arthur J.Gallagher Risk Management Services,LLC 30 Century Hill Drive Suite 200 Latham NY 12110 Susan Marlette 518-556-3130 518-869-3580 Susan_Marlette@AJG.com Southwest Marine &General Ins Co 12294 KASSSOL-01 Selective Insurance Company of America 12572KasselmanSolarLLC 279 Broadway,Building 2 Menands,NY 12204 ShelterPoint Life Insurance Company 81434 Selective Insurance Company of SE 39926 1172634107 A X 1,000,000 X 300,000 X BI/PD Ded:$5,000 5,000 1,000,000 2,000,000 X Y GL202600011431 3/24/2026 3/24/2027 2,000,000 D 1,000,000 X X X X X S 2513625 3/24/2026 3/24/2027 A X X 2,000,000EX2026000018143/24/2026 3/24/2027 2,000,000 X 10,000 C B Disability Installation Floater D441239 S 2513625 3/24/2026 3/24/2026 3/24/2027 3/24/2027 NY Statutory $500,000 Project:All Projects Certificate Holder is added to the General Liability coverage as Additional Insured if required by written contract with respect to the above project. City of Saratoga Springs Building Department 474 Broadway Saratoga Springs NY 12866 USA PART 1. To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier Please Note: Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) PART 2. To be completed by the NYS Workers' Compensation Board (Only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers' Compensation Board, the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. CERTIFICATE OF INSURANCE COVERAGE DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW 1a. Legal Name & Address of Insured (use street address only) Work Location of Insured (Only required if coverage is specifically limited to certain locations in New York State, i.e., Wrap-Up Policy) 1b. Business Telephone Number of Insured 1c. Federal Employer Identification Number of Insured or Social Security Number 2. Name and Address of Entity Requesting Proof of Coverage (Entity Being Listed as the Certificate Holder) 3a. Name of Insurance Carrier 3c. Policy effective period 3b. Policy Number of Entity Listed in Box "1a" 4. Policy provides the following benefits: 5. Policy covers: Under penalty of perjury, I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. IMPORTANT: If Boxes 4A and 5A are checked, and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier, this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B, 4C or 5B is checked, this certificate is NOT COMPLETE for purposes of Section 220, Subd. 8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers' Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. to A. Both disability and paid family leave benefits. B. Disability benefits only. C. Paid family leave benefits only. Date Signed Telephone Number Name and Title By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) A. All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B. Only the following class or classes of employer's employees: Date Signed Telephone Number Name and Title By (Signature of Authorized NYS Workers' Compensation Board Employee) DB-120.1 (10-17) Kasselman Solar LLC 279 Broadway,Building 2 Menands,NY 12204 518-478-8365 464740969 ShelterPoint Life Insurance Company City of Saratoga Springs Building Department 474 Broadway Saratoga Springs,NY 12866 USA D441239 03/24/202703/24/2026 3/25/2026 Bart Kresse Area President518-556-3130 Additional Instructions for Form DB-120.1 By signing this form, the insurance carrier identified in Box 3 on this form is certifying that it is insuring the business referenced in box "1a" for disability and/or paid family leave benefits under the New York State Disability and Paid Family Leave Benefits Law. The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in Box 2. The insurance carrier must notify the above certificate holder and the Workers' Compensation Board within 10 days IF a policy is cancelled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from coverage indicated on this Certificate. (These notices my be sent by regular mail.) Otherwise, this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent, or until the policy expiration date listed in Box 3c, whichever is earlier This certificate is issued as a matter of information only and confers no rights upon the certificate holder. This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Disability and/or Paid Family Leave Benefits contract of insurance only while the underlying policy is in effect. Please Note: Upon the cancellation of the disability and/or paid family leave benefits policy indicated on this form, if the business continues to be named on a permit, license or contract issued by a certificate holder, the business must provide that certificate holder with a new Certificate of NYS Disability and/or Paid Family Leave Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability and Paid Family Leave Benefits Law. DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article, and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand and twenty-one, the payment of family leave benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b) The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article and notwithstanding any general or special statute requiring or authorizing any such contract, shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair, that the payment of disability benefits and after January first, two thousand eighteen, the payment of family leave benefits for all employees has been secured as provided by this article. DB-120.1 (10-17) Reverse 279 Broadway Building #2 Menands, NY 12204 (518)-478-8365 (518)-953-1095 Fax I (Customer) hereby authorize Kasselman Solar LLC, to act as customer, agent & contractor, and to submit all necessary permit applications and supporting documents to the Town Building Department on my behalf. Customer Name (Print) ______________________________________________ Customer Signature__________________________________________________ Customer Address ___________________________________________________ Municipality that issues your Building Permit ______________________________ Kasselman Solar Employee Signature_____________________________________ Richard Higgins Richard Higgins 100 Union Ave Saratoga Springs , New York 12866 City of Saratoga Springs Docusign Envelope ID: DEEB715D-EB88-8793-8150-1DBB3FE0AD8B WESTSHORE DESIGN ENGINEERS, P.C. 6279 JOHNSTON RD. ALBANY Ϳ NEW YORK Ϳ 12203 WestShore Design Engineers ۅ 6279 Johnston Rd. ۅ Albany, NY 12203 Subject: Higgins Residence 100 Union Ave. Saratoga Springs, NY To Whom It May Concern, The following references the structural roof analysis of the Higgins residence located in Saratoga Springs, NY. Westshore Design Engineers has been retained in order to analyze the existing roof structure for adequacy in supporting the proposed additional loading due to rooftop solar panels. The site-specific loadings are as follows: Seismic Design Category B; basic Wind Speed of 115mph; and Ground Snow Load of 83psf, per ASCE 7-22. The Applicable codes include the 2025 NYSRC. The existing roofs consist of 2x4 at 18”o.c. with an 8’-4” span. Based on structural analysis, it has been determined that the R1 roof will require installing new collar ties between rafters without existing collar ties at 1/3 of the rafter length from the ridge below the solar panel array. With the additional structural reinforcement described above, the R1 roof is adequate to support rooftop solar panels with a maximum loading of 3psf. The panel layout is not restricted within the specified portions of roof. IronRidge UltraGrip anchors with (2) 1/4” diameter screws required at 48” on center maximum with 2.5” minimum embed, or (6) screws at 24”o.c. for deck attachment, or S-5! clamps or racking system & attachments of equal or greater design values for metal roof. Please don’t hesitate to contact us with additional requests. Thank you. Westshore Design Engineers 6/2/2026 John Eibert Nicolas Nitti, PE Director of Solar Operations President To: Kasselman Solar 279 Broadway Bldg. 2 Menands, NY Date: June 2, 2026 Ref.: 26060029 DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3.1 ELECTRICAL PLAN 1 PV-3.2 ELECTRICAL PLAN 2 PV-4 PV SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN AP P E N D I X ELECTRICAL CALCULATIONS MODULE DATASHEET INVERTER DATASHEET ARRAY WIRING BOX DATASHEET MOUNTING SYSTEM DATASHEET UL 2703 CLASS A FIRE CERTIFICATION UL 2703 GROUNDING AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER RICHARD HIGGINS PROPERTY ADDRESS 100 UNION AVENUE, SARATOGA SPRINGS, NY 12866 APN 411501 166.69-4-5 ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF SARATOGA SPRINGS UTILITY COMPANY NATIONAL GRID GENERATION, LLC UTILITY METER SERIAL NUMBER 06719147 UTILITY ACCOUNT NUMBER 17790-94102 ELECTRICAL CODE 2023 NEC (NFPA 70) FIRE CODE 2024 IFC OTHER BUILDING CODES 2025 BCNYS 2025 RCNYS 2025FCNYS THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. PV SYSTEM DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO ENERGY STORAGE PV SYSTEM DC RATING 2.64KW PV SYSTEM AC RATINGS 1.92KW, 8.0A INVERTER(S) 6 X ENPHASE IQ8MC-72-M-US PV MODULE(S) 6 X HYUNDAI HIN-T440NF(BK) PV ARRAY WIRING (1) BRANCH OF 6 IQ8MC-72-M-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF INTERCONNECTION NEW LOAD-SIDE AC CONNECTION PER NEC 705.12(B)(2) AT MSP UTILITY SERVICE 120/240V 1Φ ELECTRICAL PANEL MAIN SERVICE PANEL W/ TOP-FED 100A BUSBAR 100A MCB SITE DESIGN PARAMETERS DRY BULB EXTREME LOW -29°C (-20°F) DRY BULB 2% HIGH 31°C (88°F) DATA SOURCE ASHRAE DATASET WIND (ASCE 7-22)115 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 83 PSF 15337 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 GR I D - T I E D P V S Y S T E M HI G G I N S R E S I D E N C E 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 PROJECT SUMMARY DOC ID:53D767-2 DATE:6/9/26 CREATOR:C.P. REVIEWER:C.P. REVISIONS PV-1 6-10-2026 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MIN. WORKING CLEARANCES PER NEC 110.26. 2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL NATIONAL GRID GENERATION, LLC EQUIPMENT. 3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 4 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 5 ALL EXPOSED PV ROOFTOP CONDUCTORS NOT UNDER THE ARRAY SHALL BE PROTECTED BY A RACEWAY WITH A LISTED JUNCTION BOX AT BOTH ENDS AND COMPLY WITH NEC 690.31(A). 6 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. (N) AC COMBINER (C1), INDOOR (N) PROPOSED ROOF-MOUNTED PV ARRAY. 6/12 (27.0°) SLOPED ROOF, (6) HYUNDAI HIN-T440NF(BK) MODULES (BLACK FRAME, CLEAR BACKSHEET), 106° AZIMUTH. (6) ENPHASE IQ8MC-72-M-US MICROINVERTERS (E) MAIN SERVICE PANEL (MSP), INDOOR (N) TRANSITION BOX, OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN 3/4″ ABOVE ROOF SURFACE (E) UTILITY METER, OUTDOOR, SN 06719147 15337 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 GR I D - T I E D P V S Y S T E M HI G G I N S R E S I D E N C E 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 SITE PLAN DOC ID:53D767-2 DATE:6/9/26 CREATOR:C.P. REVIEWER:C.P. REVISIONS PV-2 6-10-2026 PV MODULE MICROINVERTER 6 IN BRANCH PM1-6 440W 1 1 2 3 4 5 6 7 8 JUNCTION BOX JB1 2 AC COMBINER COMM GATEWAY 3 CB1 20A C1 15A 9 10 MAIN SERVICE PANEL (E) GEC NN (E) RC2040M200 120/240V 1ɸ, 3W 100A BUSBAR (TOP-FED) 100A MAIN BREAKER (E) 100A CB2 20A 11 12 13 KWHR LOAD LINE KWHR LOAD LINE UTILITY METER S/N: 06719147 ACCT #: 17790-94102 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-6 6 HYUNDAI HIN-T440NF(BK)440W 418W 14.39A 13.63A 38.8V 32.3V -0.097V/°C (-0.25%/°C)30A INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER RATED CONTINUOUS CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-6 6 ENPHASE IQ8MC-72-M-US 240V NOT SOLIDLY GROUNDED 320W 1.33A 14.0A 60V 97.0% OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1 1 20A 240VAC CB2 1 20A 10KAIC 240VAC PASS-THRU BOXES AND COMBINERS RE F. QT Y.MAKE AND MODEL RATED MAX CURRENT RATED MAX VOLTAGE JB1 1 TRANSITION BOX FOR 1 CIRCUIT 30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 3 W/ IQ GATEWAY FOR PRODUCTION MONITORING 80A 240VAC PV SYSTEM SUMMARY INVERTERS PER BRANCH 6 CONT. AC CURRENT 7.98A MAX AC OUTPUT POWER 1,920 W ARRAY STC POWER 2,640 W ARRAY PTC POWER 2,505 W TOTAL CONT. AC CURRENT 7.98A MAX AC OUTPUT POWER 1,920 W DERATED AC POWER 1,920 W RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM (PVHCS), AS PER NEC 690.12(B)(2).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8MC-72-M-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33.3 THE ENPHASE IQ8MC-72-M-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE.4 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703.5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 44.0V AT -29°C (-29°C - 25°C) X -0.097V/C + 38.8V = 44.0V).7 PV ARRAY EGC SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC 250.120(C).8 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3).9 THE ENPHASE IQ COMBINER 3 CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A.10 POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(B)(2). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL. THE SUM OF 125% OF POWER SOURCE(S) OUTPUT CURRENT (7A X 1.25 = 9A) AND THE MAIN BREAKER (100A) DOES NOT EXCEED 120% OF BUSBAR RATING (100A X 1.20 = 120A). 9A + 100A <= 120A11 THE PV BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. IT SHALL NOT BE MARKED FOR "LINE" AND "LOAD".12 PV BREAKER MEETS NEC 690.12(C) REQUIREMENT FOR A RAPID SHUTDOWN INITIATION DEVICE13 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT 1.25 FACTOR APPLIED BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 11 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 8 AWG BARE, COPPER 0.96 (31°C)1.0 7.98A 9.98A 30A 29A 90 °C 30A 39FT 0.51% 21 12 AWG THWN-2, COPPER 0.75" DIA. EMT 2 20A 12 AWG THWN-2, COPPER 0.96 (31°C)1.0 7.98A 9.98A 30A 29A 75 °C 25A 62.3FT 0.82% 3 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 3 20A 12 AWG THWN-2, COPPER 0.96 (31°C)1.0 7.98A (DERS) 0.02A (LOADS) 9.98A 30A 29A 75 °C 25A 48IN 0.05% GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 UNPROTECTED, BARE EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 HI G G I N S R E S I D E N C E SINGLE-LINE DIAGRAM 53D767-2 C.P. C.P. 6/9/26 15337 PV-3.1 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 GR I D - T I E D P V S Y S T E M NTS SINGLE-LINE DIAGRAM PV-3.1 1 PV MODULE MICROINVERTER 6 IN BRANCH PM1-6 440W 1 1 2 3 4 5 6 7 8 JUNCTION BOX 2 JB1 ACCOMBINERCOMM GATEWAY 15A CB1 20A C1 3 9 10 MAIN SERVICE PANEL (E) GEC LOADSLOADS (E) RC2040M200 120/240V 1ɸ, 3W 100A BUSBAR (TOP-FED) 100A MAIN BREAKER (E) 100A CB2 20A 11 12 13 UTILITY METER LINE LOAD LINE LOAD S/N: 06719147 ACCT #: 17790-94102 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-6 6 HYUNDAI HIN-T440NF(BK)440W 418W 14.39A 13.63A 38.8V 32.3V -0.097V/°C (-0.25%/°C)30A INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER RATED CONTINUOUS CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-6 6 ENPHASE IQ8MC-72-M-US 240V NOT SOLIDLY GROUNDED 320W 1.33A 14.0A 60V 97.0% OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1 1 20A 240VAC CB2 1 20A 10KAIC 240VAC PASS-THRU BOXES AND COMBINERS RE F. QT Y.MAKE AND MODEL RATED MAX CURRENT RATED MAX VOLTAGE JB1 1 TRANSITION BOX FOR 1 CIRCUIT 30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 3 W/ IQ GATEWAY FOR PRODUCTION MONITORING 80A 240VAC PV SYSTEM SUMMARY INVERTERS PER BRANCH 6 CONT. AC CURRENT 7.98A MAX AC OUTPUT POWER 1,920 W ARRAY STC POWER 2,640 W ARRAY PTC POWER 2,505 W TOTAL CONT. AC CURRENT 7.98A MAX AC OUTPUT POWER 1,920 W DERATED AC POWER 1,920 W RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM (PVHCS), AS PER NEC 690.12(B)(2).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8MC-72-M-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33.3 THE ENPHASE IQ8MC-72-M-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE.4 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703.5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 44.0V AT -29°C (-29°C - 25°C) X -0.097V/C + 38.8V = 44.0V).7 PV ARRAY EGC SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC 250.120(C).8 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3).9 THE ENPHASE IQ COMBINER 3 CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A.10 POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(B)(2). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL. THE SUM OF 125% OF POWER SOURCE(S) OUTPUT CURRENT (7A X 1.25 = 9A) AND THE MAIN BREAKER (100A) DOES NOT EXCEED 120% OF BUSBAR RATING (100A X 1.20 = 120A). 9A + 100A <= 120A11 THE PV BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. IT SHALL NOT BE MARKED FOR "LINE" AND "LOAD".12 PV BREAKER MEETS NEC 690.12(C) REQUIREMENT FOR A RAPID SHUTDOWN INITIATION DEVICE13 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT 1.25 FACTOR APPLIED BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 11 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 8 AWG BARE, COPPER 0.96 (31°C)1.0 7.98A 9.98A 30A 29A 90 °C 30A 39FT 0.51% 21 12 AWG THWN-2, COPPER 0.75" DIA. EMT 2 20A 12 AWG THWN-2, COPPER 0.96 (31°C)1.0 7.98A 9.98A 30A 29A 75 °C 25A 62.3FT 0.82% 3 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 3 20A 12 AWG THWN-2, COPPER 0.96 (31°C)1.0 7.98A (DERS) 0.02A (LOADS) 9.98A 30A 29A 75 °C 25A 48IN 0.05% GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 UNPROTECTED, BARE EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 HI G G I N S R E S I D E N C E THREE-LINE DIAGRAM 53D767-2 C.P. C.P. 6/9/26 15337 PV-3.2 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 GR I D - T I E D P V S Y S T E M NTS THREE-LINE DIAGRAM PV-3.2 1 6-10-2026 AC COMBINER CB2 IN MAIN SERVICE PANEL MAIN SERVICE PANEL SEE NOTE NO. 3 (MSP) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. NEC 690.12(D) AND IFC 1205.4.1 SEE NOTE NO. 4 (C1, MSP) !! CAUTIONN ! MULTIPLE SOURCES OF POWER NEC 705.30(C) SERVICE EQUIPMENT LOCATION OR AN APPROVED READILY VISIBLE LOCATION (MSP) !! CAUTION:: MULTIPLEE SOURCESS OFF POWERR ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF-MOUNTED SOLAR ARRAY WITH SAFETY DISCONNECTS AS SHOWN 100 UNION AVENUE, SARATOGA SPRINGS • INSTALLED BY KASSELMAN SOLAR • (518) 478-8365 NEC 690.56 AND NEC 705.10 AC COMBINER PANEL (C1) !! WARNINGG ! EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC 705.12(B)(3) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (CB2 IN MSP) !! WARNINGG ! ELECTRIC SHOCK HAZARD. TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.13(B) SEE NOTE NO. 5 (CB2 IN MSP) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.12(D)(2) AND IFC 1205.4.3 SOLAR BACKFEED BREAKER AS MAIN PV SYSTEM DISCONNECT (CB2 IN MSP) PV SYSTEM DISCONNECT NEC 690.13(B) AC DISCONNECT (CB2 IN MSP) MAXIMUM AC OPERATING CURRENT: 8.0A MAXIMUM AC OPERATING VOLTAGE: 240V EMERGENCY CONTACT DETAILS (MSP) IN CASE OF EMERGENCY CONTACT KASSELMAN SOLAR (518) 478-8365 NEC 705.10 SOLAR BREAKER (MSP) !! WARNINGG ! POWER SOURCE OUTPUT. DO NOT RELOCATE THIS OVERCURRENT DEVICE. NEC 705.12(B)(2) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2023 NEC AND 2024 IFC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION. THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″. 4 LABEL(S) WITH MARKING, "MULTIPLE SOURCES OF POWER," SHALL BE LOCATED AT EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. 5 LABEL(S) WITH MARKING, "RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF RAPID SHUTDOWN SWITCH. THE LABEL SHALL HAVE 3/8″ TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND. 15337 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 GR I D - T I E D P V S Y S T E M HI G G I N S R E S I D E N C E 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 SAFETY LABELS DOC ID:53D767-2 DATE:6/9/26 CREATOR:C.P. REVIEWER:C.P. REVISIONS PV-4 6-10-2026 STRUCTURAL DESIGN PARAMETERS SEISMIC 0.227 SDS WIND (ASCE 7-22)115 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 83 PSF ROOF PROPERTIES ROOF MATERIAL STANDING SEAM METAL (18IN) SLOPE 6/12 (27.0°) MEAN ROOF HEIGHT 21.4FT ROOF DECKING 1X SKIP SHEATHING CONSTRUCTION RAFTERS (2X4'S), 20IN OC MODULE MECHANICAL PROPERTIES MODEL HYUNDAI HIN-T440NF(BK) DIMENSIONS (AREA) 67.8IN X 44.6IN X 1.2IN (21.0 SQ FT) WEIGHT 54.0 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR10 ANCHOR MODEL S-5! S-5-(X), 2.0IN AIR GAP FASTENING METHOD CLAMPS GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 6 54.0 324.1 MICROINVERTERS 6 2.4 14.6 LINEAR FEET OF RAIL 69 FT 0.4 30.1 ANCHORS 28 0.2 4.6 MISC. HARDWARE 11.8 11.8 TOTAL ARRAY WEIGHT 385.1 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 6 21.0 126.0 POINT LOAD (385.1 LBS / 28 ATTACHMENTS) 13.8 LBS DIST. LOAD (385.1 LBS / 126.0 SQFT) 3.06 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. CONTRACTOR MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR LOCATIONS. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-22) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER* ZONES 1, 2 NORMAL 48.0IN 36.0IN 19.2IN *FOR ROWS WITH LESS THAN 3 MODULES THE MAX. ALLOWABLE CANTILEVER SHALL NOT EXCEED 1/3 OF MAX. ANCHOR SPAN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-22 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 3.2 FT = MAX(MIN(0.4 * 21.4 FT, 0.1 * 32.1 FT), 0.04 * 32.1 FT, 3 FT) 15337 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 GR I D - T I E D P V S Y S T E M HI G G I N S R E S I D E N C E 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 ATTACHMENT PLAN DOC ID:53D767-2 DATE:6/9/26 CREATOR:C.P. REVIEWER:C.P. REVISIONS PV-5 6-10-2026 15337 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 GR I D - T I E D P V S Y S T E M HI G G I N S R E S I D E N C E 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 ATTACHMENT DETAILS DOC ID:53D767-2 DATE:6/9/26 CREATOR:C.P. REVIEWER:C.P. REVISIONS PV-6 6-10-2026 GENERAL NOTES 1 AT LEAST TWO 3′-WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS, WITH AT LEAST ONE PATHWAY ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PV ARRAY, AT LEAST ONE SUCH PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE, OR ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. (IFC 1205.2.1.1) 2 FOR PV ARRAYS OCCUPYING 33% OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A MIN. 18″-WIDE SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. (IFC 1205.2.1.2) 3 PV MODULES SHALL NOT BE PLACED BELOW AN EMERGENCY ESCAPE/RESCUE OPENING. A MIN. 3′-WIDE PATHWAY SHALL BE PROVIDED TO SUCH AN OPENING. (IFC 1205.2.2) 4 ROOF FACES WITH NO PV ARE DESIGNATED FOR FIRE VENTILATION AND ACCESS ROOF ACCESS POINT 3.0′ WIDE FIRE ACCESS PATHWAY, PER IFC 1205.2.1.1 1.5′ WIDE SMOKE-VENTILATION SETBACK, PER IFC 1205.2.1.2 PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM. 2-STORY, GROUP R3 BUILDING TOTAL PLAN VIEW ARRAY AREA IS 110.7 SQ.FT, WHICH REPRESENTS 5.7% OF TOTAL PLAN VIEW ROOF AREA (1956.5 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. 15337 279 BROADWAY BLDG 2 MENANDS, NY 12204 (518) 478-8365 GR I D - T I E D P V S Y S T E M HI G G I N S R E S I D E N C E 10 0 U N I O N A V E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 AP N : 4 1 1 5 0 1 1 6 6 . 6 9 - 4 - 5 FIRE SAFETY PLAN DOC ID:53D767-2 DATE:6/9/26 CREATOR:C.P. REVIEWER:C.P. REVISIONS PV-7 6-10-2026 CConductor, Conduit, and OCPD Sizing Validation 1. Maximum System DC Voltage Test 1.1. Enphase microinverter system w/6 Hyundai HiN-T440NF(BK) (440W)s Array Properties Array Type Microinverter Array System Description Enphase microinverter system w/6 Hyundai HiN-T440NF(BK) (440W)s Module HiN-T440NF(BK) (440W) Highest number of modules in series in a PV Source Circuit 1 Design Low Temp. -29°C Module Voc 38.8V Temp. Coefficient Voc -0.097V/C NEC Code Calculations A. Maximum Voltage of PV Source Circuit 44.04V see NEC 690.7(A) NEC 690.7(A) requires that if the PV module manufacturer provides a temperature coefficient of open-circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE 'Extreme Annual Mean Minimum Design Dry Bulb Temperature' as the design low temperature. Using these values, the module Voc (38.8V) will increase to 44.04V at the design low temperature (-29°C). (-29°C - 25°C) X -0.097V/C + 38.8V = 44.04V The module Voc at the design low temperature is 44.04V. 44.04V X 1 = 44.04V NEC Code Validation Tests 1.PV Source Circuit maximum Voc must not exceed 600V 44.04V < 600V = true PASS 2. Wire, Conduit, and OCPD Code Compliance Validation 2.1. #1: Branch cables: Microinverter to Transition Box Circuit Section Properties Conductor 12 AWG THHN/THWN-2 in Enphase Q Cable, Copper Equipment Ground Conductor (EGC) 8 AWG Bare, Copper OCPD(s) 20A Raceway/Cable Cable Lowest Terminal Temperature Rating 90 °C Maximum Wire Temperature 31 °C Power Source Description Branch of 6 IQ8MC-72-M-US microinverters Power Source Current 7.98A Voltage 240V NEC Code Calculations A. Continuous Current 7.98A see NEC Article 100 Rated continuous current is 6 X 1.33A = 7.98A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see NEC Table 310.15(B)(1)(1), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 31°C is 0.96. The fill factor for a cable that has 2 current-carrying conductors is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 30A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16, which is 30A. E. Minimum Allowed OCPD Rating 10A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 7.98A X 1.25 = 9.97A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC 250.122(A) The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 7.98A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 29A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 29A >= 7.98A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A >= 7.98A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 30A >= 7.98A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC 250.122(A)) 8 AWG >= 12 AWG = true PASS 8.EGC must meet code requirements for physical protection (NEC 250.120(C)) EGC used to bond modules and mounting system hardware shall be protected from physical damage. PASS 22.2. #2: AC Branch Output: Transition Box to AC Combiner Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 20A Raceway/Cable 0.75" dia. EMT Lowest Terminal Temperature Rating 75 °C Maximum Wire Temperature 31 °C Power Source Description Branch of 6 IQ8MC-72-M-US microinverters Power Source Current 7.98A Voltage 240V NEC Code Calculations A. Continuous Current 7.98A see NEC Article 100 Rated continuous current is 6 X 1.33A = 7.98A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see NEC Table 310.15(B)(1)(1), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 31°C is 0.96. The fill factor for a conduit that has 2 current-carrying conductors is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 25A. E. Minimum Allowed OCPD Rating 10A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 7.98A X 1.25 = 9.97A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC 250.122(A) The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see NEC 300.17 The total area of all conductors is 0.0399in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 3 0.0399in² 0.0399in² / 0.4 = 0.0998in² (Corresponding to a diameter of 0.5") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 7.98A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 29A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 29A >= 7.98A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A >= 7.98A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 25A >= 7.98A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC 250.122(A)) 12 AWG >= 12 AWG = true PASS 8.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.75in. >= 0.5in. = true PASS 2.3. #3: AC Combiner Output: AC Combiner to Main Service Panel Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 20A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75 °C Maximum Wire Temperature 31 °C Power Source Description Enphase microinverter system w/6 Hyundai HiN-T440NF(BK) (440W)s Power Source Current 7.98A Voltage 240V NEC Code Calculations A. Continuous Current 7.98A see NEC Article 100 Rated continuous current is 7.98A B. Ampacity of Conductor 30A see NEC Table 310.16 Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see NEC Table 310.15(B)(1)(1), NEC Table 310.15(C)(1), and NEC Article 100 The temperature factor for 90°C insulation at 31°C is 0.96. The fill factor for a conduit that has 3 current-carrying conductors is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see NEC 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in NEC Table 310.16, which is 25A. E. Minimum Allowed OCPD Rating 10A see NEC 240.4 NEC 690.9(B)(1) requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 7.98A X 1.25 = 9.97A F. Maximum Allowed OCPD Rating 20A see NEC 240.4(D) NEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 12 AWG see NEC 250.122(A) The smallest EGC size allowed is 12 AWG for OCPD rating 20A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see NEC 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") NEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (NEC 240.4) 20A >= 7.98A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (NEC 240.4) 29A >= 20A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (NEC 240.4) 20 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (NEC Article 100) 29A >= 7.98A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (NEC 215.2(A)(1)) 30A >= 7.98A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (NEC 110.14(C)) 25A >= 7.98A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (NEC 250.122(A)) 12 AWG >= 12 AWG = true PASS 8.Conduit must meet code recommendation for minimum size (NEC 300.17) 0.5in. >= 0.5in. = true PASS FOHIEIZVOEBJFTDPLS $PNQBUJCMF XJUI$BSQPSU "QQMJDBUJPOT 3FGFSUP)%)&4TUBOEBSEXBSSBOUZGPSEFUBJMT )%)&4501$PO.PEVMF 1&3$4UBOEBSE )%):6/%"*40-"3.0%6-& /' #, 4FSJFT 1SFNJVN/5ZQF501$PO.PEVMF )J/5/' #, ǟ)J/5/' #, ǟ)J/5/' #, ൬:FBS1SPEVDU8BSSBOUZ h.BUFSJBMTBOEXPSLNBOTIJQ ൬:FBS1FSGPSNBODF8BSSBOUZ h'JSTUZFBSEFHSBEBUJPO h-JOFBSXBSSBOUZBGUFSJOJUJBMZFBS XJUIQBOOVBMEFHSBEBUJPO JTHVBSBOUFFEVQUPZFBST )%)ZVOEBJT8BSSBOUZ1SPWJTJPOT )JHIFS #JGBDJBMJUZ -POH5FSN 3FMJBCJMJUZ )JHI&GGJDJFODZ )JHI&OE 501$PO 5FDIOPMPHZ :56)UT:56)UT 'PS3FTJEFOUJBM 'VMM#MBDL%FTJHO h*402VBMJUZNBOBHFNFOUTZTUFNT h*40&OWJSPONFOUBMNBOBHFNFOUTZTUFNT h*400DDVQBUJPOBMIFBMUIBOETBGFUZNBOBHFNFOUTZTUFNT h6-1IPUPWPMUBJD 17 NPEVMFTBGFUZRVBMJGJDBUJPO $4" h*&$4BMUNJTUDPSSPTJPOUFTUJOH h*&$"NNPOJBDPSSPTJPOUFTUJOH h*&$1PUFOUJBM*OEVDFE%FHSBEBUJPO 1*% UFTUJOH h*&$4BOEBOEEVTUUFTUJOHGPSFOWJSPONFOUBMEVSBCJMJUZ $FSUJGJDBUJPO 4BMFT.BSLFUJOH IFTTBMFT!IEDPN '30/5 4*%& 3&"3 N N NN "" N N NN ## (SPVOEJOH IPMFT ʡ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äVCMJ.$HFOVJOF$POOFDUPS$PNQBUJCMF *1 +VODUJPO#PY QBSU CZQBTTEJPEFT *1SBUFE $POTUSVDUJPO 'SPOUNN JO TFNJUFNQFSFETPMBSHMBTTXJUIIJHIUSBOTNJUUBODF BOEBOUJSFGMFDUJWFDPBUJOH 3FBSNN JO TFNJUFNQFSFETPMBSHMBTT 'SBNF "OPEJ[FEBMVNJOVNBMMPZ &MFDUSJDBM$IBSBDUFSJTUJDT )J/5YYY/' #, )J/5/' #, )J/5/' #, )J/5/' #, *UFN 6OJU #/1* #/1* #/1* /PNJOBMPVUQVU 1NBY 8 0QFODJSDVJUWPMUBHF 7PD 7 4IPSUDJSDVJUDVSSFOU *TD " 7PMUBHFBU1NBY 7NQQ 7 $VSSFOUBU1NBY *NQQ " .PEVMFFGGJDJFODZ 1PXFS$MBTT4PSUJOH 8 _ 5FNQFSBUVSFDPFGGJDJFOUPG1NBY , 5FNQFSBUVSFDPFGGJDJFOUPG7PD , 5FNQFSBUVSFDPFGGJDJFOUPG*TD , #JGBDJBMJUZ 45$*SSBEJBODF 8N͋ DFMMUFNQFSBUVSF ".5FTUVODFSUBJOUZGPS1NBY7PD*TD 5IFFMFDUSJDBMQSPQFSUJFTPG#/1*BSFNFBTVSFEVOEFSUIFJSSBEJBODFDPSSFTQPOEJOHUP8N͋POUIFNPEVMFGSPOUBOE8N͋POUIFNPEVMFSFBS "EEJUJPOBM1PXFS(BJOGSPNSFBSTJEF 1NQQHBJO 1NQQ<8> 7NQQ<7> *NQQ<"> 7PD<7> *TD<"> &MFDUSJDBMDIBSBDUFSJTUJDTXJUIEJGGFSFOUSFBSQPXFSHBJO SFGFSFODFUP8 *OTUBMMBUJPO4BGFUZ(VJEF ൬0OMZRVBMJGJFEQFSTPOOFMTIPVMEJOTUBMMPSQFSGPSN NBJOUFOBODF ൬#FBXBSFPGEBOHFSPVTIJHI%$WPMUBHF ൬ %POPUIBOEMFPSJOTUBMMNPEVMFTXIFOUIFZBSFXFU /PNJOBM.PEVMF0QFSBUJPO 5FNQFSBUVSF 0QFSBUJOH5FNQFSBUVSF _ .BYJNVN4ZTUFN7PMUBHF%$ 7 .BYJNVN3FWFSTF$VSSFOU" .BYJNVN5FTU-PBE 4FF*OTUBMMBUJPO.BOVBM 'SPOU 1B 3FBS 1B 'JSF1FSGPSNBODF 5ZQF *7$VSWFT )J/5/' #, $VSSFOU<"> 7PMUBHF<7> 0QFSBUJOH$FMM5FNQ$ 0QFSBUJOH$FMM5FNQ$ 0QFSBUJOH$FMM5FNQ$ 0QFSBUJOH$FMM5FNQ$ $VSSFOU<"> 7PMUBHF<7> *SSBEJBODF 8N *SSBEJBODF8N *SSBEJBODF8N *SSBEJBODF8N *SSBEJBODF8N DATA SHEET IQ8MC Microinverter Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8 and IQ8+ support split phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters that has integrated MC4 connectors. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ8MC-MC4-14A-DS-0122-01-EN-US-2023-02-10 #~9 (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC Microinverter INPUT DATA (DC)IQ8MC-72-M-US Commonly used module pairings 1 W 260 – 460 Module compatibility 54-cell/108 half-cell, 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 25 – 45 Operating range V 18 – 58 Min./max. start voltage V 22/58 Max. input DC voltage V 60 Max. continuous operating DC current A 14 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20 A per branch circuit OUTPUT DATA (AC)IQ8MC-72-M-US Peak output power VA 330 315 Max. continuous output power VA 320 310 Nominal (L-L) voltage/range 2 V 240/211 - 264 208/183 - 229 Phase connection Single phase/[plit phase (L-L) Single phase/[plit phase (L-L) Max. continuous output current A 1.33 1.49 Nominal frequency Hz 60 Extended frequency range Hz 47 - 68 AC short circuit fault current over 3 cycles Arms TBD Max. units per 20 A (L-L) branch circuit 3 12 10 Total harmonic distortion %< 5 Overvoltage class AC port III AC port backfeed current mA TBD TBD Power factor setting 1.0 Grid-tied power factor (adjustable) 0.85 leading – 0.85 lagging Peak efficiency %TBD TBD CEC weighted efficiency %TBD TBD Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H x W x D) 212 mm (8.3") x 175 mm (6.9") x 30.2 mm (1.2") Weight 1.1 kg (2.43 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MC-MC4-14A-DS-0122-01-EN-US-2023-02-10 The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 (X-IQ-AM1-240-3) To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable ŵ (YVEFPI 2680GIVXMƤIH 2)1% X]TI 3R enclosure • Five-year warranty •UL listed To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 2018-09-13 MODEL NUMBER -5 'SQFMRIV <-5%1IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV TVSHYGXMSR QIXIVMRK %27- ' ERH STXMSREP GSRWYQTXMSR QSRMXSVMRK ACCESSORIES and REPLACEMENT PARTS (not included, order separately) )RTLEWI 1SFMPI 'SRRIGXƎ ')0013()1 + ]IEV HEXE TPER ')0013()1 + ]IEV HEXE TPER ')0013()11+FEWIH08)1]IEVHEXETPER Plug and play industrial grade cellular modem with data plan for systems up to 60 QMGVSMRZIVXIVW%ZEMPEFPIMRXLI97'EREHE1I\MGS4YIVXS6MGSERHXLI97:MVKMR-WPERHW [LIVIXLIVIMWEHIUYEXIGIPPYPEVWIVZMGIMRXLIMRWXEPPEXMSREVIE 'SRWYQTXMSR 1SRMXSVMRK '8 CT-200-SPLIT 7TPMX GSVI GYVVIRX XVERWJSVQIVW IREFPI [LSPI LSQI GSRWYQTXMSR QIXIVMRK Circuit Breakers &6/% &6/% BRK-20A-2P-240 7YTTSVXW )EXSR &6 &6 &6 &6 &6 &6 ERH &6 GMVGYMXFVIEOIVW 'MVGYMX FVIEOIV TSPI % )EXSR &6 'MVGYMX FVIEOIV TSPI % )EXSR &6 Circuit breaker, 2 pole, 20A, Eaton BR220 )40'Power line carrier (communication bridge pair), quantity 2 <%409+ %GGIWWSV]VIGITXEGPIJSV4S[IV0MRI'EVVMIVMR-5'SQFMRIV VIUYMVIH JSV )40' XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage :%' ,^ Eaton BR series busbar rating % 1E\ GSRXMRYSYW GYVVIRX VEXMRK SYXTYX XS KVMH % 1E\ JYWIGMVGYMX VEXMRK SYXTYX 90 A &VERGL GMVGYMXW WSPEV ERHSV WXSVEKI 9T XS JSYV TSPI )EXSR &6 WIVMIW (MWXVMFYXIH +IRIVEXMSR (+ FVIEOIVW SRP] RSX MRGPYHIH 1E\ GSRXMRYSYW GYVVIRX VEXMRK MRTYX JVSQ 4: 64 A 1E\ XSXEP FVERGL GMVGYMX FVIEOIV VEXMRK MRTYX % SJ HMWXVMFYXIH KIRIVEXMSR%[MXL-5)RZS]FVIEOIVMRGPYHIH 4VSHYGXMSR 1IXIVMRK '8 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA (MQIRWMSRW ;\,\( \ \ GQ ű \ ű \ ű ,IMKLX MW GQ [MXL QSYRXMRK FVEGOIXW Weight OK PFW Ambient temperature range {'XS{'{XS{* Cooling Natural convection, plus heat shield Enclosure environmental rating 3YXHSSV 2680GIVXMƤIH 2)1% X]TI 6 TSP]GEVFSREXI GSRWXVYGXMSR Wire sizes • %XS%FVIEOIVMRTYXWXS%;+GSTTIVGSRHYGXSVW • % FVIEOIV FVERGL MRTYX XS %;+ GSTTIV GSRHYGXSVW • 1EMR PYK GSQFMRIH SYXTYX XS %;+ GSTTIV GSRHYGXSVW • 2IYXVEP ERH KVSYRH XS GSTTIV GSRHYGXSVW %P[E]W JSPPS[ PSGEP GSHI VIUYMVIQIRXW JSV GSRHYGXSV WM^MRK Altitude 8S QIXIVW JIIX INTERNET CONNECTION OPTIONS Integrated Wi-Fi FKR Ethernet 3TXMSREP'EX)SV'EX 984)XLIVRIXGEFPIRSXMRGPYHIH Cellular 3TXMSREP ')0013()1 + SV ')0013()1 + SV ')0013()11+FEWIH 08)1 (not included) COMPLIANCE Compliance, Combiner 90 '%2'7% ' 2S '*6 4EVX 'PEWW & -')7 4VSHYGXMSRQIXIVMRK%27-'EGGYVEG]GPEWW4:TVSHYGXMSR Compliance, IQ Envoy 90 '%2'7% 2S 'SRWYQTXMSR QSRMXSVMRK MW VIUYMVIH JSV )RTLEWI 7XSVEKI 7]WXIQW Enphase IQ Combiner 3 Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails® are the structural backbone preventing these results. They resist uplift, protect against buckling and safely DQGHIÀFLHQWO\WUDQVIHUORDGVLQWRWKH building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail® Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails® is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, WRVHFXUHV\VWHPVÁXVK against residential roofs. Roof Mount utilizes XR Rails, along with optional all-in-one attachments, WRVHFXUHV\VWHPVÁXVK against residential roofs. Corrosion-Resistant Materials XR Rails® are compatible with FlashFoot® and other pitched roof attachments. IronRidge®offers a range of tilt leg RSWLRQVIRUÁDW roof mounting applications. All XR Rails® are made of 6000-series aluminum alloy, then protected with an DQRGL]HGÀQLVK$QRGL]LQJSUHYHQWVVXUIDFH and structural corrosion, while also providing a more attractive appearance. XR Rail® Family The XR Rail®)DPLO\RIIHUVWKHVWUHQJWKRIDFXUYHGUDLOLQWKUHHWDUJHWHGVL]HV(DFKVL]HVXSSRUWVVSHFLÀF design loads, while minimizing material costs. Depending on your location, there is an XR Rail® to match. © 2023 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.22 Tech Brief Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof 6ORSHRIWRGHJUHHVDQG0HDQ%XLOGLQJ+HLJKWRIIW9LVLW,URQ5LGJHFRPIRUGHWDLOHGFHUWLÀFDWLRQOHWWHUV Load Rail Span Snow (PSF) Wind (MPH) 4’ 5’ 4” 6’ 8’ 10’ 12’ None 90 120 140 XR10 XR100 XR1000 160 20 90 120 140 160 30 90 160 40 90 160 80 160 120 160 XR100 XR100 is a residential and commercial mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. •·VSDQQLQJFDSDELOLW\ • Heavy load capability •&OHDU EODFNDQRGL]HGÀQLVK • Internal splices available XR10 ;5LVDVOHHNORZSURÀOHPRXQWLQJ rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. •·VSDQQLQJFDSDELOLW\ • Moderate load capability •&OHDU EODFNDQRGL]HGÀQLVK • Internal splices available XR1000 XR1000 is a heavyweight among VRODUPRXQWLQJUDLOV,W·VEXLOWWRKDQGOH extreme climates and spans up to 12 feet for commercial applications. •·VSDQQLQJFDSDELOLW\ • Extreme load capability •&OHDUDQRGL]HGÀQLVK • Internal splices available Tech Brief :PTWSPÄLK.YV\UKPUNMVY,]LY`(WWSPJH[PVU The UFO® family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge® XR Rails®. All system types that feature the UFO® family—Flush Mount®, Tilt Mount® and Ground Mount®—are fully listed to the UL 2703 standard. UFO® hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system. This leads to safer and more reliable installations. UFO® Family of Components <UP]LYZHS-HZ[LUPUN6IQLJ[<-6®) The UFO® securely bonds solar modules to XR Rails®. It comes assembled and lubricated, and FDQÀWDZLGHUDQJHRIPRGXOHKHLJKWV the g ore <UP]LYZHS-HZ[L The UFO® securely Rails®. It comes ass FDQÀWDZLGHUDQJH :[VWWLY:SLL]L The Stopper Sleeve snaps onto the UFO®, converting it into a bonded end clamp.into )6::® Splice Bonded Structural Splice connects rails with built-in bonding teeth. No tools or hardware needed. )VUKLK([[HJOTLU[Z The bonding bolt attaches and bonds the L-foot® to the rail. It is installed with the same socket as the rest of the system. .YV\UKPUN3\N A single Grounding Lug connects an entire row of PV modules to the grounding conductor. )6::® Splice Bonded Structural Splice il i h b il i Only for installation and use with IronRidge products in accord with written instructions. See IronRidge.com/UFO :`Z[LT+PHNYHT <3*LY[PÄJH[PVU The IronRidge® Flush Mount®, Tilt Mount®, and Ground Mount Systems have been listed to UL 2703 by Intertek Group plc. UL 2703 is the standard for evaluating solar mounting systems. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. 0YVU9PKNL0UJ(SSYPNO[ZYLZLY]LK=PZP[^^^PYWH[LU[ZJVTMVYWH[LU[PUMVYTH[PVU=LYZPVU Tech Brief *YVZZ:`Z[LT*VTWH[PIPSP[` -LH[\YL -S\ZO4V\U[ ;PS[4V\U[ .YV\UK4V\U[ XR Rails®((XR100 & XR1000 UFO®/Stopper ((( BOSS® Splice ((N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Compatible with most MLPE manufacturers. Refer to system installation manual. Fire Rating Class A Class A N/A Modules Tested or Evaluated with over 400 Framed Modules Refer to installation manuals for a detailed list. í Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for JURXQGLQJOXJVDQGÀHOGLQVWDOOHGHTXLSPHQWJURXQGFRQGXFWRUV(*&$PLQLPXPRIWZRPLFURLQYHUWHUVPRXQWHGWRWKH same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. .V[V0YVU9PKNLJVT<-6 '!$"$#"##$ !#" 3URGXFWPDUNLQJVDUHORFDWHGRQWKH*URXQGLQJ/XJEROW !" $ "# 43-462784$"# "8)3+)6+-46")-,8<0678+08043493803."<78,27493803.,:0*,71)2503. !,8,38043,:0*,7)3+6493+9.7-46$7,;08/1)8 1)8, /484:418)0*4+91,7)3+ )3,17 -6FRSHRI(YDOXDWLRQLQFOXGHVERQGLQJJURXQGLQJPHFKDQLFDOORDGLQJDQG¿UHFODVVL¿FDWLRQ - +)%(%%!'%"''))'! - +"(, '. -0RGXOH2ULHQWDWLRQ3RUWUDLWRU/DQGVFDSH -6\VWHP'HVLJQ/RDG5DWLQJ36)GRZQZDUG36)XSZDUG36)ODWHUDO -$FWXDOV\VWHPVWUXFWXUDOFDSDFLW\LQFOXGLQJVSDQVDQGFDQWLOHYHUVDUHGH¿QHGE\3(VWDPSHGFHUWL¿FDWLRQOHWWHUV -&$026SHFL¿F'HVLJQ/RDGUDWLQJ36)GRZQZDUG36)XSZDUG36)ODWHUDO &HUWL¿HGWR&6$7,/1R$3KRWRYROWDLF0RGXOH5DFNLQJ6\VWHPV -/RDG5DWLQJ3$>36)@ """("#!!# !$ -$Q\5RRI6ORSHZLWK0RGXOH7\SHVDQG$OORZHGZLWKDQ\URRIVORSH$Q\PRGXOHWRURRIJDS &#% ''*'!"#% '%(%!%$(% -0RGXOH7\SHVDQG$OORZHGZLWK6WHHS6ORSH5RRIV$Q\PRGXOHWRURRIJDSLVSHUPLWWHGORZHGJH (%!% %$(% -&ODVV$UDWHG39V\VWHPVFDQEHLQVWDOOHGRQ&ODVV$%DQG&URRIVZLWKRXWDႇHFWLQJWKHURRI¿UHUDWLQJ """("#!!# !$ -0RGXOH7\SHVDQG$OORZHGZLWK6WHHS6ORSH5RRIV$Q\PRGXOHWRURRIJDSLVSHUPLWWHGZLWKQR #% '%(%!%$(% &#!"!#" -8/DQG7$6$)ODVKIRRW/0RXQW)ODVKYXH$OO7LOH+RRN.QRFNRXW7LOH+DOR8OWUD*ULS - &'!)('*'"('&!' -$Q\URR¿QJPDQXIDFWXUHUDSSURYHGVHDODQWLVDOORZHG -5DWLQJVDSSOLFDEOHIRUVWHHSURRIVORSHVDQGDERYH $ !#" -&RQIRUPVWR8/68%-(&7$+DOR8OWUD*ULSDQG%8* -6WHHS6ORSH5DWLQJVDSSOLFDEOHIRU$VSKDOW6KLQJOHURRIVZLWKVORSHVDQGXS -/RZ6ORSH5DWLQJVDSSOLFDEOHIRU5ROO5RR¿QJ5ROOHG&RPSURRIVZLWKVORSHVDQGXS -/RZ6ORSH5DWLQJVDSSOLFDEOHIRU0RGL¿HG%LWXPHQ0RG%LWURRIVZLWKVORSHVDQGXS -,QVWDOOHUPXVWYHULI\URRIVORSHSULRUWRLQVWDOOLQJ+8*RU%8*WRYDOLGDWHDSSOLFDEOHURRIW\SHV !"#$"# !##" "#%"&! - #%'! #%'(%! '" -0D[LPXP/RDGOEV -)RURXWGRRUXVH "#!$#$!!## -'HVLJQHGDQG&HUWL¿HGIRU&RPSOLDQFHZLWKWKH,QWHUQDWLRQDO%XLOGLQJ&RGH $6&(6(, ! !$# !% -$SSURYHGIRULQVWDOODWLRQERWKLQVLGHDQGRXWVLGH+LJK9HORFLW\+XUULFDQH=RQHV+9+= - '"!'&!(&'"##%")" #"!!'&!"(!% Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, Wisconsin 53562 Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) Signature: Name: Nalini Mandadi Position: Project Engineer Date: 11/14/2014 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address:Enstall US, Inc. 41 West Putnam Avenue, Suite 303 Greenwich, CT 06830-5300 USA Product Description:Flush Mount System with XR Rails. Ratings & Principle Characteristics: Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low and Steep Slope applications when using Type 1, 2, 3, 13, 19, 25, 29 and 38 listed photovoltaic modules, no perimeter guarding is required. Class A Fire Rated for Steep Slope applications when using Type 4 and 5 listed photovoltaic modules and required perimeter low edge guarding. Class B Fire Rated for Steep Slope applications when using Type 4 and 5 listed photovoltaic modules, no perimeter guarding is required. Tested with a 5” gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. This rating is applicable with any 3rd party roof attachment with similar construction and material. Models:IronRidge Flush Mount with XR Rails Brand Name:IronRidge Flush Mount Relevant Standards:UL 2703 (2023)(Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office:Intertek Testing Services NA, Inc. 8431 Murphy Drive, Middleton, WI 53562 Date of Tests:08/27/2014 to 03/17/2015 Test Report Number(s):101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, 104428358MID-001 EEV, 105041839MID-001 & 002, 105499394MID-008 PEV Revision Summary 08/27/2020 Added type 13, 19, 25 and 29 to system, update address. 06/28/2022 Added Type 5. 09/14/2022 Added Type 4. 12/8/23 added type 38. 1/5/24 changed word anchor to attachment. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by:Brian Brunson Reviewed by:Chad Naggs Title:Operations Manager, Middleton Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 01/05/24 Date: 01/05/24 The S-5-U clamp is our most popular and versatile clamp ¿ttinJ aEout 5 oI the standinJ seam pro¿les in North America. ® ® ® Th e r i Jht Za\ t o a t t a c h a l m o s t a n \th i n J t o m e t a l r o o Is S- 5 - U a n d S - 5 - U M i n i - 5- _ ZZ Z .S - 5 . c o m _ S-5-U Clamp The S-5-U clamp is by far our most popular and most versatile clamp. It fits about 85% of the standing seam profiles manufactured in North America—including most structural and architectural profiles. It can be used on vertically oriented seams and, by rotating the clamp 90 degrees, it can also be used on most horizontal 2" seam profiles. Its simple design, generous dimensioning, and multiple hole orientations are what make the S-5-U clamp so versatile for use with the S-5!® snow retention products, such as ColorGard®, as well as with other heavy-duty applications. Installation is as simple as setting the specially patented round-point setscrews into the clamp, placing the clamp on the seam, and tightening them to the specified tension. Then, affix ancillary items using the bolt provided with the product. Go to www.S-5.com/tools for information and tools available for properly attaching and tensioning S-5! clamps. S-5-U Mini Clamp The S-5-U Mini is a bit shorter than the S-5-U and has one setscrew rather than two. The mini is the choice for attaching all kinds of rooftop accessories: signs, walkways, satellite dishes, antennas, rooftop lighting, lightning protection systems, solar arrays, exhaust stack bracing, conduit, condensate lines, mechanical equipment—just about anything!* *S-5! mini clamps are not compatible with, and should not be used with S-5! SnoRail™/SnoFence™ or ColorGard® snow retention systems. Please note: All measurements are rounded to the second decimal place. Distributed byS-5!® Warning! Please use this product responsibly! Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength, setscrews should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5! website at www.S-5.com for published data regarding holding strength. Copyright 2015, Metal Roof Innovations, Ltd. S-5! products are patent protected. S-5! aggressively protects its patents, trademarks, and copyrights. Version 052115. The strenJth oI the S-5-U clamp is in its simple desiJn. The patented setscreZs Zill sliJhtl\ dimple the metal seam material Eut not pierce it² leavinJ the rooI manuIacturer s Zarrant\ intact. S-5-U Mini Clamp S-5-U Clamp Note: ,nstall Eoth setscreZs on same side oI clamp. 1.50" .00 mm 0.90" .00 mm 0.0" 10.00 mm 1.50" .00 mm M hole located 1" 1.00 mm Irom edJe oI part 0.5" 1.00 mm 1.50" .00 mm 0.90" .00 mm 0.0" 10.00 mm 1.50" .00 mm M holes centered on part 0.5" 1.00 mm 1.1" 0.00 mm .00" 51.00 mm ([ample Pro¿les For horizontal seams under 0.65", do not use this clamp. Visit www.S-5.com for more detailed information and proper clamp usage. The S-5-U and S-5-U Mini clamps are each furnished with the hardware shown to the right. Each box also includes a bit tip for tightening setscrews using an electric screw gun. A structural aluminum attachment clamp, the S-5-U is compatible with most common metal roofing materials excluding copper. All included hardware is stainless steel. Please visit www.S-5.com for more information including CAD details, metallurgical compatibilities and specifications. The S-5-U clamp has been tested for load-to-failure results on most major brands and profiles of standing seam roofing. The independent lab test data found at www.S-5.com can be used for load-critical designs and applications. S-5!® holding strength is unmatched in the industry.