HomeMy WebLinkAbout20260521 Henning Rd Verizon Utility Pole ApplicationTransaction Record Fedla,
TRACKING NO.: SHIP DATE: ESTIMATED TOTAL COST:
873503251603 Jun 24, 2026 33.73 USD
From address
Lisa Krutka
YOUNG SOMMER LLC
500 Federal Street, 5th Floor
FI 5
12180 NY TROY
US
Phone:5184389907
lkrutka@youngsommer.com
To address
Mark Graham, Admin. Asst. APED
City of Saratoga Springs
474 Broadway
12866 NY SARATOGA SPRINGS
US
Phone:5185873550
Package information
Pieces Weight
Dimensions (LxWXH) Carriage value Package options
1 x 1.00 lb
nla
Packaging type:
Service: Pickup l drop-off type:
FedEx Envelope
FedEx Nacional 1 0:30 a.m. I have already scheduled a pickup at my
location
Billing information
Bill transportation cost to:
******419 P.O. No.:
Bill duties, taxes and fees to:
Invoice No.:
Your reference:
11889.57 & 11889.96 Department No.:
Please note: This transaction record is neither a statement nor an invoice, and does not confirm shipment tendered to FedEx or payment. FedEx will not be responsible
for any claim in excess of $100 per package, whether the result of loss, damage, delay, non -delivery, misdelivery, or misinformation, unless you declare a higher value,
pay an additional charge, document your actual loss and file a timely claim. Limitations found in the current FedEx Service Guide apply. Your right to recover from FedEx
for any loss, including intrinsic value of the package, loss of sales, income interest, profit, attorney's fees, costs, and other forms of damage whether direct, incidental,
consequential, or special is limited to the greater of $100 or the authorized declared value. Recovery cannot exceed actual documented loss. Maximum for items of
extraordinary value is $1000, e.g., jewelry, precious metals, negotiable instruments and other items listed in our Service Guide. written claims must be filed within strict
time limits; Consult the applicable FedEx Service Guide for details. The estimated shipping charge may be different than the actual charges for your shipment. Differences
may occur based on actual weight, dimensions, and other factors. Consult the applicable FedEx Service Guide or the FedEx Rate Sheets for details on how shipping
charges are calculated,
Young. Sommer,.-,.,._,.-,
ATTORNEYS AT LAW
MAIN OFFICE (FOR ALL MAIL): Soo FEDERAL STREET, 5TH FLOOR, TROY, NEW YORK 12180
ALBANY OFFICE: 41 STATE STREET, STE 604-12, ALBANY, NEW YORK 12207
Phone: 518-438-9907 o Fax: 518-438-9914
www.youngsommer.com
June 24, 2026
Vial Feder -a 11
Mark Graham
Administrative Assistant for OPED
City of Saratoga Springs
474 Broadway
Saratoga Springs, New York 12866
David C. Brennan, Esq.
Writer's Telephone Extension: 224
dbrennan@youngsommer.com
RE: Cellco Partnership d/b/a Verizon Wireless Application for DRB Approval
Utility Pole No. NM 17NZ 15 — Along Henning Rd.
Dear Mr. Graham:
Please find enclosed an application to the Design Review Board for a proposal to add a
wireless small cell antenna and equipment to a replacement utility pole in the public right of
way.
Also enclosed is a check in the amount of $650.00 for the application fee.
We look forward to discussing this further with the Design Review Board at an upcoming
meeting. In the meantime, if you have any questions concerning this letter or the enclosed
materials, please contact me at your convenience.
Very truly yours,
Z
i
David C. Brennan, Esq.
Encl.
DESHGI\\J ► EVHEW BOARD
CHT"Y OF SARATOGA SPRINGS, S RATOGA COUC \\\ITY,N_I W'`i1ORK
In the Matter of the Application of
C EELLCO Pl\I,�1RT INE RS HP
dyb/a-�Ve:inzo W Lre ess
Utility Pole No. NM 17/VZ 15
Along Henning Rd.,
Saratoga Springs, New York 12866
P'- J. P ICA�TION FOR D E-i SIGN R►�VHE�W BOARD APPROVAL
a Lno! STATEMENT OF IINTTENT
Submitted bV:
Verizon Wireless
Kathy Pomponi o - Network Real Estate
175 Calkins Rd
Rochester, New York 14623
(585) 321-5365
Tectonic Engineering & Surveying Consultants, P.C.
Steven Matthews, P.E.
36 British American Blvd, Suite 101
Latham, New York 12110
(518) 783-1630
Airosmith Development Inc.
Sara Colman, Site Acquisition Specialist
318 West Ave.
Saratoga Springs, NY 12866
(518) 461-7114
Please Direct Correspondence T®o
Young/ Sommer LLC
David C. Brennan, Esq.
500 Federal Street, 5th Floor
Troy NY,12180
(518) 438-9907
Dated: June 24, 2026
DESIGN REVIEW BOARD OF THE CITY OF SARATOGA SPRINGS
SARATOGA COUNTY, NEW YORK
In the Matter of the Application of
CELLCO PARTNERSHIP d/b/a Verizon Wireless
Premises: Utility Pole No. NM 17/VZ 15 -Along Henning Rd
Saratoga Springs, New York 12866
STATEMENT OF INTENT and
APPLICATION FOR DESIGN REVIEW BOARD APPROVAL
I. Purpose and Need
CELLCO PARTNERSHIP d/b/a Verizon Wireless ("Verizon Wireless" or the
"Applicant") proposes the collocation of an unmanned public utility/personal wireless service
facility (a "communications facility") at the above location. More specifically, Verizon Wireless is
proposing to add wireless telecommunications equipment to the proposed replacement utility
pole.
The Applicant proposes to install on a replacement utility pole: a single, cylindrical
antenna (approximately 24" tall x 14.6" in diameter) mounted at the top of the pole at a tip height
of 41.7± feet along with the installation of electric and telecommunications equipment on the
utility pole at a minimum height of 8' above grade. All proposed equiprnient zvill be painted brown as
noted on Sheet C-2B and consistent with prior DRB approvals for similar projects. The existing utility
pole measures 33.2± feet in height, the proposed utility pole measures 38.5± feet. The property is
located in the right of way along Henning Rd., City of Saratoga Springs, Saratoga County, New
York (NM 17/ VZ 15) . [Zoning Site Plan Drawings of Tectonic Engineering Consultants,
Geologists & Land Surveyors, D.P.0 at TAB 6].
Upon completion, the proposed facility will provide additional wireless network
bandwidth and improved performance to the nearby roads and the surrounding neighborhood
areas, as shown in the accompanying coverage maps. More specifically, the site is proposed
improve coverage and network performance along the surrounding portion of Henning Rd.
[Proposed Coverage Map at TAB 31.
Verizon Wireless is considered a public utility for land use purposes under New York
decisional law (Cellular Telephone Conipan y v, Rosenberg', 82 N.Y.2d 364 [1993]), and a provider of
"personal wireless services" under the federal Telecommunications Act of 1996 (the "TCA").
Verizon Wireless' equipment will be in Operation twenty-four (24) hours a day, seven (7) days a
week, three hundred sixty-five (365) days a year.
1 In Rosenberg, the State's highest Court determined that the ordinary variance standard is inapplicable and a cellular
telephone company applying for relief need only show that (1) the relief is "required to render safe and adequate
service," and (2) there are "compelling reasons, economic or otherwise," for needing the variance. Cellular Telephone
Company v. Rosenberg, 82 N.Y.2d 364, 372 (1993).
1
Verizon Wireless is .applying for review by the Design Review Board,2 The proposed
replacement pole is located in the Rural Residential (RR) Zoning District. The facility is not
located in the Historic Review District or the Architectural Review District.
The proposed communications facility is unmanned and will be visited for routine
maintenance purposes approximately two times per year (only as needed). As such, the project
will not have any impact on existing water and sewage services. In addition, neither pedestrian
nor vehicular access to the premises will be impacted [see Zoning Drawings at TAB 6].
II. Compliance with City Requirements
The proposed communications facility complies in all material respects with City
requirements:
1. SEQRA: A Short Environmental Assessment Form is attached as TAB 2.
2. Minimum Visual Impact: As noted above, Verizon Wireless' proposed facility is
designed to have a minimum possible visual effect on the surrounding community
and neighborhood [TAB 4].
3. Site Plan: The Applicant has provided a Zoning Site Plan that identifies the
proposed improvements [TAB 6].
Based upon the foregoing, Verizon Wireless respectfully submits that approval is
appropriate in this case.
III. Conclusion
The communications facility proposed is a public necessity under Rosenberg in that it is
required to render adequate and safe service to this area of the City of Saratoga Springs. In an
effort to supplement existing telecommunications services to this area of the City Verizon
Wireless has identified an appropriate location for the deployment of a small cell facility. Verizon
Wireless' existing macro cell sites in the area do not provide adequate coverage and capacity to
this area of the City. The City of Saratoga Springs will be lacking adequate and safe capacity, and
the failure to approve this application will eliminate the means to provide necessary capacity.
This, combined with the federal mandate to expeditiously deploy advanced wireless services
across the nation and Verizon Wireless' FCC licenses to provide such services in the City of
Saratoga Springs, demonstrates that Verizon Wireless' facility is a public necessity. Without the
construction of the communications facility proposed, the public would be deprived of an
essential means of communication, which, in turn, would jeopardize the safety and welfare of the
community and traveling public.
The small cell facility will not be noticeable to the traveling public or nearby property
owners. The communications system proposed has been sited to have the least practical adverse
2 For the reasons set forth herein, Verizon Wireless believes that its project complies in all material respects with the
provisions of the City of Saratoga Springs Land Use Laws and, consistent with the application process established by
the City for prior Small Cell applications, that no additional approvals or relief are required. To the extent that an
additional approval or relief is required, Verizon Wireless submits these materials in support of such approval(s).
2
visual effect on the environment, and any resulting impact(s) may properly be considered as
minimal in nature and scope.
Attached to this Application and Statement of Intent are the following:
1) An Application for Architectural/Historic Review by the Design Review Board;
2) A Short Environmental Assessment Form;
3) Radio Frequency Coverage Plots:
4) Photosimulations of the proposed installation and SEQRA Visual EAF Addendum;
5) Radio Frequency -Site Compliance Report; and
6) Project Zoning Drawings.
Kindly place this matter on the agenda for discussion at the next available meeting of the
Design Review Board. In the meantime, if you should have any questions or require any
additional information concerning this project, I can be reached at (518) 438-9907.
Thank you for your consideration.
Dated: June 24, 2026
Respectfully submitted,
CELLCO PARTNERSHIP d/ b/ a Verizon Wireless
« 1
David C. Brennan, Esq.
Regional Local Counsel
3
-AY+lANDVVR1TTEli APPLIC ATIONS WILL NOT BE ACCEPTED-1r1;!%,
1FOR OFFICE USEI
TY OF A RATO ASPRINGS
� ;C
AM A
DESIGN REVIEW BOARD
CITY HALL - 474 BROADWAY
SARATOGA SPRINGS NEW YORK 12866-2296
TEL: 518-587-3550 X2533
www.sai-atoga-spi-ings.org
APPLICATION FOR. -
ARCHITECTURAL/ HISTORIC REVIEW
(Application #)
(Project Title)
Staff Review
APPLICANT(51"" OWNER If not Aee fAt—ITORNEY/AGENT
Name Cellco Partnership d/b/a Verizon Wirele! National Grid David C. Brennan, Esq.
Address 1275 John St., Suite 100 300 Erie Blvd W 500 Federal St, FI- 5
West Henrietta, NY 14586 Syracuse, NY 13202 Troy, NY 12180
Phone 518-714-9282 , j
......... ..
F M ai I dbrennan@youngsommer.com
Identify primary contact person: 0 Applicant 0 Owner 7---! Attorney/Agent
... An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question.
Applicant's interest in premises:
PROPERTY INFORM" A T[ON
® Owner 1@ Lessee 0 Under option to lease or purchase
ROW along Henning Rd. Utility Pole NA
Property Address/Location: No: N A: 11M7jVzt1-3 Tax Parcel #:
( for avample: 165.52 — 4 — 37)
Date Acquired by Owner:
RR
Current Zoning District: Property use: 0 Residential M Non-residential/mixed-use
Type of Review: El Architectural ® Historic 11 Extension/modification (of current approval)
Summary description of proposed action:
Collocation of an unmanned public ufflifty/personal wireless service facility on a replacement wooden utility pole Nvitll the
antenna tip height of 41.7 +/- ft.
Has a previous application been filed with the DRB for this property?
IN No 0 Yes — date(s)?
Revised 12/21025
5
"A complete' application consists of 1hard copy Loriginal) d I electronic copy of apKhcation & kLL oL-�u'l Sr,
.r1C11,11r-''-a�r[,a-k as rrequired below:
New Construction /.Additions
M--- Color photographs showing site/exterior details of existing structures and adjacent properties
E� A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures
along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all
setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning
district on 1 7"xl 1 " sheet.
0 Elevation drawings showing design of all sides of existing 84 proposed construction — label dimensions, colors, materials, lighting (fi,,&,ture
Rt lamp type, wattage), etc. - include compass beafi-ing & scale; no larger than Tx,3' sheet — smaller permitted if legible
8 4>
10 Floor plans for proposed structure; on sheet no larger than 2x3' — smaller permitted if legible
El Product literature, specifications and samples of proposed materials and colors
Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only)
-1-1 Color photographs showing site/exterior details of existing structures and that illustrate affected features
0 Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp
type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller perrnitted if legible
0 Product literature, specifications and samples of proposed materials and colors
Within front yard setbacks in Historic Distric (Front setbacks: UR-1 "11\!ST-HTR=30';UR-4=25'-,UR-2,UR-3(",.INCUD-1=10')
Installation, removal or change in material of drive- and wall(ways
Installation or removal of architectural, sculptural or vegetative screening over 3' in height
Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter)
For any of above:
0 Color photographs showing site/exterior details of existing structures, and of adjacent properties
1.71 Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than TO' sheet — smaller
preferred if legible
® Product literature, specifications and samples of proposed materials and colors
Signage / Awnings
0 Color photographs showing site/exterior details of existing structures, and adjacent properties
® Plan showing location of proposed sign/awning structure on building/premises., no larger than I I "x 17"
El Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type,
dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware
0 Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location
El Product literature, specifications and samples of proposed materials and colors
1671-3011TOWINSTAI
0 Color photographs showing site/exterior details of existing structures, and of adjacent proper -ties
13 Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing., and scale
0 Written description of reasons for demolition and, in addition:
El For structures of "architectural/Historical significance", demonstrate "good cause" why structure cannot be preserved
13 For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a
44 contributing" structure in a National Register district (contact City staff' , provide plans for site development following demolition -
include a timetable and letter of credit for project completion
Telecommunication facilities
Color photographs showing site/existing structures, and of adjacent properties
Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale
Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details
Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact
assessment and existing and proposed vegetative screening
Revised 12/2025
.Request for extension of current approval
0 Identify date of original DRB approval: Current expiration date,
-
Org. App. No.
L71- Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the
neighborhood.
SEOR Environmental AsSessinnent Form
ffl.. Applicants proposing the following must complete "Part I" of the SECT Short Environmental Assessment Form (available here:
http://%"w.dec.ii . ov/docs ermits q operations df/seafpijrtonc_._jQd0:
Construction or expansion of a multi -family residential structure (4 units +)
Construction or expansion (exceeding 4,000 sq, ft. gross floor area) of a principal or accessory non-residential structure
Telecommunications facility, radio antennae, satellite dishes
Demolition
f �, kz; c I n f� i i r cm -
Does any City officer, employee or family nnamber thereof have a financial interest (as defined by General Municipal Law
Section 809) in this application?
,7�- No -0 Yes - If yes, a statement disclosing the name, residence, nature, and ex^tent of this interest must be filed with this
application,
certification
1/we, the property owner(s), or purchaser(s)/Iessee(s) under contract, of the land in question, hereby request an appearance
before the Design Review Board.
By the Signature(s) attached hereto, I/we certify that the information provided within this application and accompanying
documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing
false or misleading information is grounds for immediate denial of this application.
I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated
with this application for purposes of conducting any necessary, site inspections relating to this application.
F C>
Furthermore, I/we agree to meet all requirements Linder Article V11 for Historic Review or Article VIII for Architectural
Review of the Zoning Code of the City of Saratoga Springs.
Date:
(applicant signature)
Date:6/24/26
(applicant signature)
If applicant is not the currently the owner of the property, the current owner must also sign.
Owner Signature-.'
Owner Signature:
Date:
Bate:
Revised 12/2025
I I 0GI
CITY OF ARATO A SPRINGS
DESIGN Ri-n/lIEW BOARD
City Hall. - 474 Broadway
Saratoga Springs, New York 12-866
Tel: 518-587-3550 x2533
www.saratoga-springs.org
INSTRUCTIONS
A RC H I T E C T u R A L I H I S T U R �n "R,1E Vi L----- %�- �\ f" P F01 1CAT11 0 N
ELIGIBILITY: An applicant to the Design Review Beard for Architectural Revietpj or Historic Review must be
-11.he property ov�iner(s) or lessee, or have an option to lease or purchase the property in question.
2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is
complete. The DRB will only consider properly completed applications that contain 1 o, cai nd� I
chi itall version of the application and ALL other required materials as indicated on the application.
HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTEMI,
3. ACTIONs REQUIRING REVIEW:
Architectural Review District Historic Review District
• any exterior changes that require a building permit
. .......... . . . ................ 1--1-- ....... -.1- . ....... . ......
Installation or exterior change to a structure requiring a
• any change in exterior building materials
building or demolition permit
• a new, or change to an existing, sign or sign structure
-
any material change to exterior of a structure including:
c, demolition of a st=ructure
addition or removal of exterior architectural features
installation, removal or material changes to exterior
Within a non-residential zoning district:
building elements Such as roof, siding, windows, doors,
• a change in exterior building color
porches, etc.
• installation of an awning
enclosure or screening or buildings openings such as
windows, doors, porches, etc.
installation of utility, mechanical or misc. accessory
structures to the exterior of a building such as HVAC
equipment, solar panels, wind turbines, radio/satellite
transmission/reception devices, etc.
Within a front yard setback:
installation, removal or material changes to drive- or
walkways
installation or removal of architectural, sculptural or
vegetative screening that exceeds 3' in height
o installation of accessory utility structures or
radio/satellite- transmission/reception devices over 2' in
diameter
a change in exterior building color within a non-
residential zoning district
a new, or change to an existing, sign or awning
installation of telecommunications facilities
Note — Ordinary maintenance or repair that does not involve a change in material, design or outer appearance
is exempt from Historic or Architectural Review,
Revised 12/2025
k. DESIGN GUIDELINES:
The Design Review Board will evaluate whether the proposed action (construction, alteration or demolition) is
compatible with existing structures and surrounding properties using the following criteria:
• Height — consistent with historic form and context of site and surrounding properties
• Scale — relationship of structure and its architectural elements to human size, form, perception
• Proportion — relationship among building elements including front facade, windows, and doors
• Rhythm — pattern resulting from repeating building elements such as door/window openings, columns,
arches, and other faqade elements
• Directional Expression — compatibility with horizontal & vertical expression of surrounding structures
• Massing & Open Space — relationship of structure to open space between it and adjoining buildings
o, kntbalck- — cornpatibility with surrounding strUMTe.S
c Compatibility of the follmlvino- with surrounding structures/properties:
Major building elements (store'ronts, doors, windows, roof
- Building materials
- Color — (in non-residential zoning districts only)
i. I L
PECISIONS: The Design Review Board may approve, approve with conditions, or disapprove an application.
.4
The F,--' ; RC ,' may -impose appropriate conditions and safeeuards in connection with its approval including nature/
t..a
quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on
the grounds of hardship.
Ne I 'r, has Sufficiently
Application approvals shall e.."Pire x.A.11-1-hin H9 months of the filing date unless the project
commenced (i.a. building/demolition permits obtained and construction/alteration begun). Applicants may
request up to 2 extensions if requested before expiration date of prior approval.
6. AGENDA DATE: Check City's website (www.saratoga--sprin s.oFg) for rneeting dates. Applicatimis are
placed on an agenda on first -come, first -served basis as determined by the completeness of the application.
7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "'Commissioner of Finance"
REFER TO THE CURRENT FEE WORKS HEET INCLUDED IN THIS DOCUMENT.
ADDITIONAL INFORMATION:
More detailed information on Architectural Review, Historic Review and the Design Review Board responsibilities may be found in the City's
Unified Development Ordinance available in City Hall and on the Cites -Areb site at https-./Iny-saratogaspri.n.gs.civiCPILLS.com/DocumentCenter/
View/17803/Full -UDO
Revised 12/2025
City of Saratoga Springs
OFFICE OF ?L4*1fflNG AIXID E-CONOMIC DEVELO?NlEi°!T FEES - 2026
Applicadon to City Council
FEE .... ....... ......... . . .
Comprehensive Plan Amendment
....... . . . .... ... . ..... . . ....... ..... ............... .....
$1,800 + $300/acre
Zoning Ordinance Amendment
$800 + $300/acre
Planned Unit Development (PUD) Amendment - -- - ------ - ------------
$800 + $3001acre ........
Application to Zoning Board of Appeals
F E_ E
...... . .. ...
. . .
Use GG
Variance
Area Variance Residential (1 & 2 Family)
S1,400 + $75/,app
$35011 st var + S75/app + $1 50/ea add variance
Area Variance - 3+ Family and Commercial
$1,000/1st var + $75/app, + $2001ea add variance
Interpretations
$650 + $75/app
Post Work Application Fee
Application Fee x2 + $705/app
Variance Extensions
50% of Application Fee + $75/app
__..,__ ......... ....... . ...... I.-
....... ...... ..... ..... .. ... ............ . .............. . .. . .................... . . . . . .. . ..
Application to Design Revlevv Board �7_ EEE
...... ....
Demolition
$500
Residential Structures — 1 or 2 Family, Principal or Accessory Structure.
Materials Change - roof, windows, siding
$75
Fagade Change - removal/addition of windows., doors, porch
$ 150
Addition or new construction
$300
Approval Extension
50% of Application Fee
3+8%,lulti-Family, Cor irD_JAixed-qse Principal or &qessory Structure
Equipment Install or Materials Change - roof, windows, siding, paint color
$150
Signs, awnings
11�0 150
'
Facade Change - removal/addition of windows, doors, porch
$300
Addition or new construction
$650
ApprOV21 Extension or Modification
50% of Application Fee
Post Work Application Fee
Application Y,2
Application to Planning Board
Special Use Pen -nil
$1,200 + S75/app
Temporary Use Pert -nit
$500
Special Use Permit - Extension
$400
Special Use Permit - Modification
$550 + $75/app
Site Plan Review - incl. PUD
Sketch Plan
$400 per sketch
Site Plan Full
Residential
$400 + $250/unit
Non -Residential I Mixed -use
$800 + $150/1,000 sf (Non -Res) + 250 unit (Res)
Administrative SPR
Residential
$400
Non -Residential / Mixed -use
$800
Extension
Residential
$250
Non -Residential / Mixed -use
$350
Subdivision - incl. PUD
Sketch Plan
$400 Per sketch
Preliminary Approval
Residential: 1-5 Lots
$700 + $75/app
Residential: 6-10 Lots
$1..100 + $75/app
Residential: 11-20 Lots
$1,450 + S751app
Residential, 21+ Lots
$1,800 + $75/app
Residential - Extension
$350
Final Approval
Residential
$1,550 + $200/lot + $75/app
Non -Residential
$2,400/lot + $75/app
Final Approval Modification
Residential
$400 + $75/app
Non -Residential
$800 + S75/app
Final Approval Extension
Residential
$250
Non -Residential
$350
Subdivisions and Site Plans are subject to Engineering Review-
See DPW Fees
Other
Lot Line Adjustment/Subdivision Administrative Action
Letter of Credit — !Modification Extension
Letter of Credit - Collection
Recreation Fee
Land Disturbance Activity Permit
WatercourselWetland Pemiit
WatercourseMetland Permit Entension
SEORA EIS Review (Draft & Final)
Sidemik Fee Lieu
Tree Removal
$400
$400
LIP to 1 % of LoC
$2,OO011ot or unit
$750 + $35/acre
$750
$350
TSD
See, DPW Fps
Avg, nursery cost in caliper of new species equivalent to
diameter at breat height (DBH of tree(s) Removod
�� L` r'! �'/� ?/� // (1 � ;1 ��!II t:��/J`•/� 1 f, /1rr��1 ��' rrfJ,��-i7 I ) r?� ��\ (77YYr'n /✓�' n/ �� lr! T / �`J�, l/l/'
L✓ L L L f_`�✓ r L Imo✓ )..✓ I.i� lY J L/ I `/� ( �' ����� 1
Part I - jF�roll�'�'�`� lrn?�C�J��1fLApr!
1 i 5f�t-uk�_c tf' � si 3 D�oir Co ie_ta
_-- -
P - rt 1 — Project lnforniation. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the
application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on
information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as
thoroughly as possible based on current information,
Complete all items in Part 1. You rnay also provide any additional information you believe will be needed by or useful to the lead
agency; attach additional pages as necessary to supplement any item.
Name of Action or Project:
Cellco P-lartnership, d/b/a Verizon Wireless - Unmanned wireless Facility - "Rood & Riddle"
Project Location (describe, and attach a location neap):
Right-of-way of Denning Rd, City of Saratoga Springs, Saratoga County, NY 12866
Brief Description of Proposed Action:
Cellco Partnership d/b/a Verizon wireless ("Verizon Wireless" or "Applicant14) is proposing an unmanned wireless
communications facility on a proposed replacement wood utility pole on Henning Rd. The subject pole is located
on the Southeast side of the right-of-way of Denning Rd, approximately 0.66 miles south of Lake Ave.
In general, the installation consists of the following: one (1) antenna mounted at a centerline height of 40.7'
above grade on a proposed 35.5' (41.7' including antenna height) tall replacement wood pole. All accessory
equipment, cabling and utility services (power and fiber) are proposed to be mounted to the good pole.
Name of Applicant or Sponsor:
Telephone: 585 321.5 435
I l'-'-�Vlai.l: kathy.pomponio@verizonwireiess.com
Cellco Partnership d/b/a Verizon wireless; attn: lathy Pomponio
Address:
175 Calkins Load
City/PC):
State:
Lip Code:
Rochester
NY
14623
1. Does the proposed action only involve the legislative adoption of a plan, local law. ordinance,
NO
YES
administrative rule, or regulation?
If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that
may be affected in the municipality and proceed to Part 2. if No, continue to question 2.
2. Does the proposed action require a permit, approval or funding from any other government Agency?
NO
YES
If Yes, list agency(s) name and perrnit or approval: City of Saratoga Springs - Design Review Board approval; Building permit
--
3. a. Total acreage of the site of the proposed action? <0.0001 acres
b. Total acreage to be physically disturbed? <o.00n, acres
c. Total acreage (project site and any contiguous properties) owned
or controlled by the applicant or project sponsor. <0.0001 acres
4. Check all land uses that occur on, are adjoining or near the proposed action:
M Urban. Pn� Rural (non -agriculture) ❑ Industrial Commercial M Residential (suburban)
E01 Forest Agriculture 0 Aquatic Q Other(Specifyy):
Saratoga Race Track, 1-87
0 Parl(land Corridor
Page 1 of 3 SEAF 2026
5. Is the proposed action., � .�._._..__._..�...�..m..�.�_
a. A permitted use under the zoning regulations'?
b. Consistent with the adopted comprehensive plan'?
NO
YES
NIA
�
6. Is the proposed action consistent with the predominant character of the existing built or natural landscape?
NO
YES
7. .Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area?
If Yes, identify:
NO
YES
8. a. Will the proposed action result in a substantial increase in traffic above present levels?
b. Are public transportation services available at or near the site of the proposed action?
c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed
action?
NO
YES
- -
✓
9. Does the proposed action meet or exceed the state energy code requirements?
If the proposed action will exceed requirements, describe design features and technologies:
NO
YES
I Q. Will the proposed action connect to an existing public/private water supply?
If No, describe method for providing potable water:
Proposed action does not require a potable water supply.
NO
YES
✓
11, Will the proposed action connect to existing wastewater utilities?
If No, describe method for providing wastewater treatment:
Proposed action does not require wastewater treatment.
NO
YES
12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district
which is listed oil the National or State Register of Historic Places, or that has been determined by the
Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the
State Register of Historic Places?
The project is substantially contiguous to the Union Avenue Historic District.
b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for
archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory?
NO
YES
✓
13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain
wetlands or other waterbodies regulated by a federal, state or local agency?
b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody`?
If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres:
Federal Wetlands adjoin the project site. The project does not propose any wetland
disturbance.
NO
YES
✓
Page 2 of 3 SEAF 2026
1.4. Identify the typical habitat types that occur on, or are .Likely to be round on the project site. Check all that apply:
❑ Shoreline [* Forest [❑ Agricultural/grasslands ❑ Early Enid -successional
❑ wetland ❑ 'Urban FMI Suburban
1.5.Does the site of the proposed action contain any species of anirnal, or associated .habitats, listed by the State or
I� ederal government as threatened or endangered`?
NO
YES
RI
El
16. Is the project site located in the 100-year or 500-year flood plain?
NO
YES
17. will the, proposed action create storm water discharge, either from point or non -point
sources? If Yes,
a. will stor n water discharges flow to adjacent properties?
b. will storm water discharges be directed to established conveyance systems (runoff and storm drains)?
If Yes, briefly describe:
NO
YES
E]_
1:1
18. Does the proposed action include construction or other activities that Would result in the impoundment of Water
or other liquids (e.g., retention pond, waste lagoon, dam)?
If Yes, explain the purpose and size of the impoundment: r�
NO
YES
19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste
management facility?
If Yes, describe:
NO
YES
21
20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or
completed) for hazardous waste?
If Yes, describe:
NO
YES
21. Is the project located within, or within '/z mile of, a disadvantaged community?
If No, could impacts from the project affect a disadvantaged community?
If Yes to either question in. 21, answer the following question.
a. Identify the potential pollution impacts of the project, either direct or indirect, that may occur within the
disadvantaged community (e.g., wastewater discharges, air emissions, noise, odors, solid or hazardous waste
generation or management):
NO
YES
�
1 CERTIFY THAT T'HE INFORMATION PROVIDED ABOVE I'S TRUE AND ACCURATE rro THE BEST OF
MY KNOWLEDGE
Applicant/sponsor/name: Steven Matthews, agent on behalf of applicant Date: 6/15/2026
Signature: M-a-, Title: Director of Engineering
Page 3 of 3 SEAF 2026
1�'�.1;1C�;;[f��ir�.1.1 Monday, June 15, 2026 9:15 AM
J
n5a Foil, Rapor.
Disclaimer The EAF Mapper is a screening tool intended to assist
project sponsors and reviewing agencies in preparing an environmental
assessment form (EAF). Not all questions asked in the EAF are
answered by the EAF Mapper. Additional information on any EAF
question can be obtained by consulting the EAF Workbooks. Although
the EAF Mapper provides the most up-to-date digital data available to
DEC, you may also need to contact local or other data sources to
confirm data provided by the Mapper or to obtain data not provided by
the Mapper.
SLU'd
K I U1 C, 1) 11) e
n
u b t6
H,)ni ill.an
Dn
BLIf fak)
:A I h
, USGS.
S Err, HERE, G:wil-r&)
E;i H �I:11)0 K, %r, 'i K i ES-1
7.
9L , E5 i . i,. I I E P, El. l' PIS
Whn hi I I oh
Part 1 / Question 7 [Critical Environmental
No
Area]
Part 1 / Question 12a [National or State
Yes
Register of Historic Places or State Eligible
Sites] . . ......... .
Part 1 Question 12b [Archeological Sites]
No
Part 1 Question 13a [Wetlands or Other
Yes - Digital mapping information on local, Ne\ivi York State, and federal
Regulated Waterbodies]
wetlands and waterbodies is known to be incomplete. Refer to the EAF
Workbook.
Part 1 Question 15 [Threatened or
No
Endangered Animal]
Part 1 Question 16 [100 or 500 Year
Digital mapping data are not available or are incomplete. Refer to EAF
Floodplain]
Workbook.
Part 1 Question 20 [Remediation Site]
No
Part 1 Question 21 [Disadvantaged
No
Community]
Short Environmental Assessment Form - EAF Mapper Summary Report I
IA
E
■
d)
to
4)
E >
00
&Z
LO
Q CL
u 0-
N CL
O
N
M�
;r
4LA kid
'Lbd& OIIILI�O'lk
AAW dr
Pl
.01
4%
AA
6L
y
ti•
r'
X
1l�
... ,
46
ftL
.� t„ • -
lop b
IWO
_ • .. _ 1 . •r., ., :fir•' _ !
•
.�• .1 is _
r it :�s Wit••
r• i*i• • S�a't.
lip
.:,` � � #fir }f• , � ti +�,• r �"' �'
•1 ,
O
N
a- J
J16
so,
t
41
ilk•
. w
7p
4FV
:1
14'il
4000��
1 le
1,
•
Ile
14
1%V I
I no-44
tow, r
46
tIr♦.
T
�•w' I
a
Y � , J%wA-3
r
IF
16-4,e
4
•
.
r•
I
k-M
c all,
�—
a:
en
17.26
Appendix B
State Environmental Quality Review
VISUAL EAF ADDENDUM
This form may be used to provide additional information relating to Question 11 of Part 2 of the Full EAF.
(To be completed by Lead Agency)
Distance Between
Visibility
Proj'ec�
cand L�(F�-.,'esacujrce (in Miles)
1 Would the project be visible from:
to - 1'/4
V4 - '/2
ii,�-2- 3
3- 5
5+
A parcel of land which is dedicated to and available
to the public for the use, enjoyment and appreciation
of natural or man-made scenic qualities?
An overlook or parcel of land dedicated to public
E
El
0.
E
observation, enjoyment and appreciation of natural
or man-made scenic qualities?
A site or structure listed on the National or State
El
0
Registers of Historic Places?
State Parks?
E J
I The State Forest Preserve?
I National Wildlife Refuges and State Game Refuges?
0
El
1:1
I National Natural Landmarks and other outstanding
0
F1
El
1:1
natural features?
I National Park Service lands?
El
1:1
I Rivers designated as National or State Wild, Scenic
or Recreational?
I Any transportation corridor of high exposure, such
L
F-7
L_J
Li
as part of the Interstate System, or Amtrak?
A governmentally established or designated interstate
11
El
07
D
El
or inter -county foot trail, or one formally proposed for
establishment or designation?
A site, area, lake, reservoir or highway designated as
scenic?
Municipal park, or designated open space?
El
El
0
County road?
0
—1
0
F
'1
1
State road?
F]
Local road? Henning Rd, Morrisey Ln
0
2. Is the visibility of the project seasonal? (i.e., screened by summer foliage, but visible during other seasons)
E]Yes ZNo
3. Are any of the resources checked in question I used by the public during the time of year during
which the
project will be visible?
Fv_�Yes No
f ll'trGuQ� CIF 00STING 111 UAh1- --NViR JP lW PVT
From each item checked in question 1, check those which generally describe the surrounding environment.
;Y V ! i �
` l� n 110'
Essentially undevelopedEl;
i
Forested
Agricultural
i
Suburban Residential
Industrial
�
Commerical
�-
Urban
River, Lake, Pond
Cliffs, Overlooks
Designated O S
en Space
9 p p
i
Flat
0
Hilly
D
Mountainous
Other
NOTE: add attachments as needed
5. Are there visually similar projects within:
1
�% mile Yes No I mile yes No 2 miles Yes 1110
3 miles Yes
01 1110
i
*Distance from project site is provided for assistance, Substitute other distances as appropriate.
6. The annual number of viewers likely to observe the proposed project is
,V0 1--ff when user data is unavailable or unknown, use best estimate.
2 Million ?
C0NTE X T
7. The situation or activity in which the viewers are engaged while viewing the proposed action is:
FREQUENCY
H- olidays/
Aothdt1f
Daily
weekly
Weekends
Seasonally
Travel to and from work
Q
o
0
0
Involved in recreational activities
Q
p
0
0
Routine travel by residents
C
®
0
0
At a residence
0
0
0
At worksite
O
O
O
Other
0
p
O
Q
Reset
circet
USA
Verizon Wireless
Site Compliance Report
Site name - ROOD & RIDDLE
Site Name: ROOD & RIDDLE
Site Address: Along Henning Road, City of Saratoga Springs, NY, 12866
Structure Type: Utility Pole
Report Information
Report Date: May 22, 2026
Report Generated by: Mamta Venna
Customer Contact: Rick Andras
Compliance Statement
Verizon Compliance Statement: Verizon Wireless is compliant with FCC rules and regulations in all publicly accessible
areas.
of: NEW
�PG�PRLES Co
��
T
02
o
7k' � as 70
n Z
m��t�` �86835
OAROFESS1��P�
David C. Cotton, Jr.
Licensed Professional Engin er
State of New York, 086838
Date: 2026-May-29
Warning: It is a violation of New York State Law, Article 145, Section §7209 for any person, unless acting
under the direction of a licensed professional engineer, to alter this document in any way.
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA * 19422
cirmcet
USA
Contents
1. Executive Summary........................................................................................................................................................3
2. Antenna Inventory .........................................................................................................................................................4
3. Analysis...........................................................................................................................................................................5
4. Appendix A: Reference Information............................................................................................................................... 6
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell o PA * 19422
circet
USA
1. Executive Summary
Verizon Wireless has contracted with Circet USA, an independent Radio Frequency consulting firm, to determine
if the proposed telecommunications facility is in compliance with Federal Coirununications Commission (FCC)
rules and regulations regarding RF exposure as defined in 47 CFR § 1.1307(b) and 1.1310. This document and the
conclusions herein are based on the information provided by representatives of Verizon Wireless which is assumed
to be true and correct.
All information used in this report was analyzed to determine compliance in publicly accessible areas, in particular
at ground level. The analysis evaluates the telecommunications facility with respect to the General
Population/Uncontro I led Maximum Permissible Exposure (MPE) limits. Circet USA has taken into consideration
the Verizon Wireless antenna system as well as any existing antenna systems at the subject location.
Verizon Wireless final antenna count is (1) antenna.
Based on the analysis, Circet USA has determined that:
Verizon Wireless is compliant in all publicly accessible areas with the FCC rules and regulations governing human
exposure to RF electromagnetic fields as described in 47 CFR § 1.1307(b) and 1.1310.
With the proposed Verizon Wireless antenna configuration in service, the composite exposure from this facility in
all areas at ground level will be less than 1 % of the General Population MPE limit, or over 100 times less than the
maximum allowed exposure in publicly accessible areas.
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell * PA 9 19422
cirmcet
USA
2. Antenna Inventory
The table below contains data provided by Verizon Wireless representatives and/or gathered by
Circet USA personnel. This data was used to perform the RF exposure analysis.
Ant ID
Owner
Antenna manufacturer
Antenna model
(o) Mech. Tilt
Azimuth (°)
Height (ft)
Frequency band
Elec. c. Tilt
HBW (�)
VBW (°)
Total power
(Watts)
Gain (dBd) ERP (Watts)
1
Verizon
XvVN Wireless
CX160r,.11236-BF22
0
0
! 40.7
LTE 1900
2
360
27.1
I 63.5
5.25
213
1
Verizon
SSA Wireless
CX160MI236-BF22
0
0
I 40.7
AWS3 LTE 2100
2
360
27.1
190.6
5.25
639
1
Verizon
JrvttA, Wireless
CX160N11236-BF22
0
0
40.7
NR 3.7GHz
2
360
9.4
142.9
7.65
832.05
Notes: Each row with the some number in the Antenna ID column references the some physical antenna. Power values provided by the client and used in the analysis
may be greater than what is initially deployed.
80% TDD Duty Cycle and 100% FDD Duty Cycle are used.
Jumper/connector/coax loss between RRHs and antenna
AWS/PCS: 2 dB
C-Band: 2.5 dB
1777 Sentry Parkway W. Building 11 a Suite 201 Blue Bell e PA • 19422
circet
USA
3. Analysis
Circet USA has included the Verizon Wireless antenna system at the subject location in the
analysis. All existing and proposed antennas are listed in the antenna table above. Engineering
assumptions were used when. specific antenna or operating parameter information was not
available for the other existing collocated antennas (if applicable).
Using this data, software modeling using IXUS software was performed for all transmitting
antennas located at the site. Circet USA has assumed a 100% duty cycle and maximum radiated
power. The site has been modeled with these assumptions to determine the maximum potential
RF energy density at ground level. Circet USA believes this to be a worst -case analysis based
on the best available data.
As stated previously, based on this analysis, the calculated ground level exposure from the
Verizon Wireless antenna system alone is less than 1 % of the General Population MPE limit.
Keep in mind that the FCC did not arbitrarily establish their own standards but rather adopted
the recommendations of national and international organizations such as the National Council
on Radiation Protection and Measurements (NCRP), the American National Standards Institute
(ANSI) and the Institute of Electrical and Electronics Engineers (IEEE). These
recommendations were developed by expert scientists and engineers following extensive
evaluation of the potential biological effects from RF exposure. The FCC MPE limits are based
on thresholds for known adverse effects, and they were designed to provide a substantial
margin of safety. There is a safety factor of 50 built into the General Public MPE limits, and the
predicted Verizon Wireless exposure levels are over 100 times below these very conservative
limits.
In cases where such compliance exists, the subject of electromagnetic field safety is preempted
by the Telecommunications Act of 1996, which states: "No state or local government or
instrumentality thereof may regulate the placement, construction, and modification of personal
wireless service facilities on the basis of the environmental effects of radio frequency emissions
to the extent that such facilities comply with the (Federal Communication) Commission's
regulations concerning such emissions."
The graph below provides a visual depiction of the rather insignificant electromagnetic field
exposure contribution from the Verizon Wireless antenna system out to a distance of 500' from
the base of the structure. This portrays how low the Verizon Wireless contribution is when
compared to the General Population MPE limit.
?/6 General Public MPE vs Distance
120
100
LU
80
a
1-i 60
v
a
40
20
0
0 50 100 150 200 250 300 350 400 450 500
Distance (ft)
-VZW MPE Contribution -FCC MPE limit
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell 9 PA • 19422
crcet
USA
4. Appendix A: Reference Information
FCC Rules & Regulations
All information used in this report was analyzed as a percentage of the MPE limits as detailed in 47 CFR S
1.131 0. The calculated power density at each sample point divided by the limit at each calculated frequency
provides a result in % MPE. Summing the calculated % MPE from all contributors provides accumulative
01/0 MPE at a particular sample point. Wireless carriers use different frequency bands with varying MPE
limits; therefore, it is useful to report results in terms of % MPE as opposed to power density.
All results were compared to the FCC radio frequency exposure rules as detailed in 47 CFR § 1.1307(b) to
determine compliance with the MPE limits for General Population/Uncontrolled environments as defined
below:
1 wo Uli NSHICHtlulls lur Exposure LIMIts
Occupational — Applies to situations in which persons
are "exposed as a consequence of their einploym-ent"
and are "fully, alvare of the potential for exposure and
can exercise control over their exposure".
Environment Classification
General Population — Applies to situations in which
persons are "exposed as a consequence of their
employment maynot be made fidly aii,,are of the potential
for exposure or cannot exercise control over their
exposure". Generally speaking, those without significant
and documented RF Safety & Awareness training would
be in the General Population classification.
Controlled — Applies to environments that are restricted Uncontrolled — Applies to environments that are
or "controlled" in order to prevent access from members unrestricted or "uncontrolled" that allow access from
of the General Population classification. members of the General Population classification.
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422
circet
USA
FCC Limits for Maximum Permissible Exposure (MPE)
Plane -wave Equivalent Power Density
1000
N 100
0
1
E 10
� 1
L
3
Q. 0.1
0.01
— Occupational
—General Public
'0000/
0 1 10 100 1, 000 101000
Frequency (MHz)
The MPE limits defined in 47 CFR § 1. 13 10 and utilized in this analysis are outlined in the table and diagram
below:
Vin t8 for Occu atlonallControlled Exposure
Frequency
Electric Field
Magnetic Field
Power Density
Averaging Time
Range
Strength
Strength
(S)
E ', H , or S
(MHz)
(E) (N7/m)
(H) (Alm)
(MW/cm')
(minutes)
0.3-3.0
614
1.63
(100)*
6
3.0-30
1842/f
4.89/f
(900/f2)*
6
30-300
61.4
0.163
1.0
6
300-1500
--
--
f/300
6
1500-100,000
--
--
5
6
Lim tS or General Po tllatlolllUncontrolled Exposure
Frequency
Electric Field
Magnetic Field
Power Density
Averaging Time
Mange
Strength
Strength
(S)
JE 12, 1111112, or S
(MIIz)
(E) N'/m)
(II) (A/m)
(m�'�'/cm-)
(minutes)
0.3-1.34
614
1.63
(100)*
30
1.34-30
824/f
2.19/f
(180/f2)*
30
30-300
27.5
0.073
0.2
30
300-1500
--
--
f/1500
30
1500-1005000
--
--
1.0
30
f = fr•equericy iii AM..:
* = Plane -wave equivalent power densi
1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA * 19422
FtfrcitY St 4
S17E
Road b Ridzatcza
Hospital I
VA
/4
w
Yc'ddc lard 5
VICINITY MAP
DIRECTIONS
DIRECTIONS TO SITE:
FROM NORTH GREENBUSH SWITCH FACILITY, TURN LEFT ONTO JORDAN
RD. TURN LEFT ONTO US-4 N/N GREENBUSH RD. AT THE TRAFFIC
CIRCLE, TAKE THE 1ST EXIT ONTO US-4 N. TURN LEFT ONTO
MORRISON AVE. TURN LEFT ONTO NY-378 W/HIGH ST. USE THE RIGHT
LANE TO MERGE ONTO 1-787 N VIA THE RAMP TO COHOES. MERGE
ONTO I-787 N. USE THE RIGHT LANE TO MERGE ONTO NY-7 W VIA
THE RAMP TO I-87/SCHENECTADY/SARATOGA SPRINGS. TAKE THE
EXIT ONTO 1-87 TOWARD SARATOGA SPGS/GLENS FLS. TAKE EXIT 14
FOR NY-9P TOWARD NY-29/SARATOGA SPRINGS/SCHUYLERVILLE. USE
THE RIGHT LANE TO TAKE THE RAMP ONTO NY-9P N/UNION AVE.
USE THE RIGHT LANE TO MERGE ONTO NY-9P N/UNION AVE. TURN
RIGHT ONTO HENNING RD. THE SITE WILL BE ON THE RIGHT.
CELLCO PARTNERSHIP,
d/b/a
■
��erizon
ROOD RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
UTILITY POLE #: NIVI 17/VZ 15
SITE ADDRESS:
ALONG HENNING RD
SARATOGA SPRINGS, NY 12866
MUNICIPALITY:
CITY OF SARATOGA SPRINGS
COUNTY:
SARATOGA
TAX MAP NUMBER:
PUBLIC R.O.W.
STRUCTURE COORDINATES:
43.074339'
—73.754579'
GROUND ELEVATION:
262'± AMSL
POLE OWNER:
NATIONAL GRID/VERIZON
POLE #:
NM 17/VZ 15
APPLICANT:
VERIZON WIRELESS
1275 JOHN STREET, SUITE 100
WEST HENRIETTA, NY 14586
CONTACT PERSON:
KATHY POMPONIO
CONTACT PHONE:
(585) 321-5435
PROJECT SUMMARY
PROJECT DESCRIPTION
THE PROPOSED WORK CONSISTS OF:
• REMOVE EXISTING WOODEN UTILITY POLE. REPLACE WITH A
PROPOSED 45' (CLASS 1) 'WOODEN UTILITY POLE AND RELOCATE
ALL APPURTENANCES TO THE PROPOSED POLE.
• INSTALL (1) CELLULAR ANTENNA & ASSOCIATED EQUIPMENT ON
PROPOSED POLE.
• INSTALL ELECTRICAL, TELCO AND CABLE ROUTING .AS NECESSARY.
SHT.
NO.
DESCRIPTION
REV
NO
REVISION
DATE
T-1
TITLE SHEET
1
06/09/26
GN-1
GENERAL NOTES
1
06/09/26
C-1
SITE PLAN & EQUIPMENT PLAN
1
06/09/26
C-2A
MAKE READY SCOPE OF WORK
1
06/09/26
C-2B
POLE ELEVATION & DETAIL
1
06/09/26
C-3
POLE MOUNT DETAILS
1
06/09/26
E-1
ELECTRICAL & GROUNDING DIAGRAMS & DETAILS
1
06/09/26
SHEET INDEX
THIS SET OF PLANS SHALL NOT BE UTILIZED AS CONSTRUCTION DOCUMENTS
UNTIL ALL ITEMS OF CONCERN HAVE BEEN ADDRESSED AND EACH OF THE
DRAWINGS HAS BEEN REVISED AND ISSUED "FOR CONSTRUCTION".
SUMMARY OF MAKE READY WORK
I. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC
MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS,
2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH
TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450)
3. REPLACE SPAN OF NEUTRAL TO P18 WITH 250' OF 1 /0 TPX.
4, ATTACH TPX AT 31'6".
5. REPLACE SEC BRACKETS (NG 10-101 FIG 5).
6. REPLACE PRI DG (NG 3-105).
7. INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE.
NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK.
CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION
STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT
SPECIFICATIONS.
LICENSE APPLICATION #ROOD & RIDDLE/MDG:5000993724
WORK REQUEST #30352102
UTILITY PROVIDERS
ELECTRIC PROVIDER:
NATIONAL GRID
ESR #:
31326318
ACCOUNT #:
47801-80005
FEEDER#:
XXXXX
PLANNER:
TBD
PHONE:
(XXX) XXX—XXXX
FIBER:
VER€ZON
Before You Dig, Drill Or Blast!
Dig � Safely.
New York
UNDERGROUND FACILITIES
PROTECTIVE ORGANIZATION
CALL US TOLL FREE 1-800-962-7962
NY ind:uYial code rule 7,53 requires no less thar, two
working days r:ot:e, but not more than ten cay3 notice.
DIG SAFELY - N EW YORK
DO NOT SCALE DRAWINGS
THESE DRAWINGS ARE FORMATTED FOR 22'*x34" FULL SIZE AND 11"x17"
HALF SIZE. OTHER SIZED VERSIONS ARE NOT PRINTED TO THE SCALE
SHOWN. CONTRACTOR SHALL VERIFY ALL PLANS, EX"STING DIMENSIONS
& CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE
ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH
THE WORK OR BE RESPONSIBLE FOR SAME.
verizon
175 CALKINS ROAD I
ROCHESTER, NY 14623
Tectoni
*c
..ACTI� SOLB'f1CML EXCRI,ON" 31111MCIL
Teetonle EnOww" Cmm&wrte, Waloglele 4 land &eveyore, Q.P C.
Pevj.ct Confaer Info
38 Br;tleh Amerlcan Blvo. Phone: (518) 783-16M
Suite 101 (800) 829-6531
Latham. NY 12110 w�w.tectcnicengineering.com
NO NUMBER DRAWN BY REVIEWED BY
12861.115 LP1F MP
Alf% r%ATC' lecl1:
0
05/06/26
FOR REGULATORY
1
06/09/26
ADDED PAINT NOTE
UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN
BEARING THE SEAL OF A LICENSED ENGINEER OR LAND
SURVEYOR 15 A VIOLATION OF SECTION 7209
SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION
LAW.
COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE
OF THE SIGNATURE AND AN ORIGINAL EMBOSSED
SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF
THE PROFESSIONAL ENGINEER OR LAND SURVEYOR
SHALL NOT BE CONSIDERED VALID COPIES.
0 1
ORIGINAL SIZE IN INCHES
(22x34 FORMAT)
0 1
ORIGINAL SIZE IN INCHES
(11 x17 FORMAT)
SITE INFORMATION
ROOD & RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
SITE ADDRESS
UTILITY POLE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
TITLE SHEET
SHEET NUMBER
T�l
ELECTRI CAL NOTES
1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT
SPECIFICATIONS, NEC AND ALL APPLICABLE LOCAL CODES.
2. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED.
3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT
ACCESS TO EQUIPMENT IS NOT BLOCKED.
4. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE
REQUIREMENTS OF THE NEC.
5. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS
REQUIRED BY THE NEC.
6. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING, AND T1
CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL
TAPE (3M BRAND, 1 /2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL).
THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA.
7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED. ALL EQUIPMENT SHALL BE
LABELED WITH THEIR VOLTAGE RATING, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT
ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S).
8. PANELBQARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS)
SHALL BE CLEARLY LABELED.
9. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE
SINGLE CONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2,
STRANDED COPPER CABLE RATED FOR 90"C (WET AND DRY) OPERATION; LISTED OR
LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED.
10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR
(#6 AWG OR LARGER), 600 V. OIL RESISTANT THHN OR THWN-2 GREEN INSULATION,
STRANDED COPPER CABLE RATED FOR 90'C (WET AND DRY) OPERATION; LISTED OR
LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED.
11. POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR,
TYPE USE-2 CABLE (##14 AWG OR LARGER), 600 V, OIL RESISTANT RHW-2 OR XHHW-2,
STRANDED COPPER CABLE RATED FOR 90-C (WET AND DRY) OPERATION; WITH OUTER
JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED.
12. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE
LUGS AND W fRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL
BE RATED FOR OPERATION AT NO LESS THAN 90'C.
13. ELECTRICAL METALLIC TUBING (EMT) OR RIGID METALLIC CONDUIT (RMC) SHALL BE USED
FOR EXPOSED OR CONCEALED LOCATIONS.
14. ALL OUTDOOR EXPOSED CONDUIT SHALL BE PVC SCHEDULE 80 AND SHALL BE SUPPORTED
ADEQUATELY.
15. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED OUTDOORS,
WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. LFMC SHALL CONFORM TO NEC
ARTICLE 350.
16. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND
APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE.
17. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN
ACCORDANCE NTH NEMA, UL, ANSI/IEEE. AND NEC.
18. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE
GALVANIZED OR EPDXY -COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED
NEMA 3R (OR BETTER) OUTDOORS.
19. IF REQUIRED, CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE
AND COORDINATE REQUIREMENTS, SERVICE ROUTING, AND METER SOCKET TYPE WITH LOCAL
POWER COMPANY.
20. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS.
21. CONTRACTOR SHALL LABEL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.16 AND
110.24.
22. CONTRACTOR SHALL VERIFY THAT THE MAIN BONDING JUMPER AND GROUNDING ELECTRODE
CONDUCTOR IS INSTALLED PROPERLY AT SERVICE ENTRANCE.
23. WHERE ELECTRICAL POWER IS TO BE SUB -FED FROM AN EXISTING DISTRIBUTION SYSTEM,
THE FOLLOWING SHALL APPLY:
A. CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND
PER N.E.C. ARTICLE 220.
B. CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE
CALCULATED PER N.E.C. ARTICLE 220.
C. EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS
EQUIPMENT SUPPLYING IT.
D. PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE
LOCATED IN EXISTING PANEL.
ANTENNA MOUNTING NOTES
1. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO
ANSI /TIA-222-H-2017 "STRUCTURAL STANDARD FOR ANTENNA
SUPPORTING STRUCTURES, ANTENNAS AND SMALL WIND TURBINE
SUPPORT STRUCTURES". THE BUILDING CODE OF NEW YORK STATE, AND
ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL CODES.
2. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN
ACCORDANCE WITH ASTM A123 "ZINC (HOT -DIP GALVANIZED) COATINGS
ON IRON AND STEEL PRODUCTS", UNLESS OTHERWISE NOTED.
3. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE
GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC -COATING (HOT -DIP)
ON IRON AND STEEL HARDWARE", UNLESS OTHERWISE NOTED.
4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD
GALVANIZING IN ACCORDANCE WITH ASTM A780 "REPAIR OF DAMAGED
AND UNCOATED AREAS OF HOT -DIP GALVANIZED COATINGS", USING COLD
GALVANIZING COMPOUND AS MANUFACTURED BY ZINGA-USA OR ZINC
KOTE, OR ENGINEER APPROVED EQUAL WITH A MINIMUM METALLIC ZINC
CONTENT OF 95% BY WEIGHT 1N DRY FILM. DRY FINISHED COATING
THICKNESS SHALL BE 3 MILS MINIMUM.
5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE NUTS AND
SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS.
6. DESIGN OF THE ANTENNA MOUNTING BRACKETS, SUPPORTS, AND ALL
COMPONENTS THEREOF AND ATTACHMENT THERETO SHALL BE THE
RESPONSIBILITY OF THE MANUFACTURER. MANUFACTURER SHALL PROVIDE
THE OWNER DRAWINGS DETAILING ALL COMPONENTS OF THE ASSEMBLY,
INCLUDING CONNECTIONS, DESIGN LOADS, AND ALL OTHER PERTINENT
DATA. MANUFACTURER SHALL ALSO PROVIDE THE OWNER WITH A
STATEMENT OF COMPLIANCE, INDICATING THAT THE ANTENNA SUPPORTS
HAVE BEEN DESIGNED IN ACCORDANCE WITH ANSI/TIA-222-H
STANDARDS. ALL SUBMISSIONS SHALL BEAR THE SIGNATURE AND SEAL
OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK.
STRUCTURAL NOTE
1. THE VERIFICATION OF STRUCTURAL ADEQUACY AND DESIGN OF THE
ATTACHMENTS MUST BE PERFORMED, PRIOR TO THE COMMENCEMENT
OF CONSTRUCTION, BY A PROFESSIONAL ENGINEER LICENSED IN THE
STATE OF NEW YORK.
2. REFER TO STRUCTURAL ANALYSIS REPORT PREPARED BY XXXXXXXXXXX
DATED XX/XX/XX.
GROUNDING NOTES
GROUND TESTING AFTER CONSTRUCTION:
1. AFTER COMPLETION OF CONSTRUCTION OF THE CELL SITE GROUND SYSTEM,
A POST INSTALLATION GROUND TEST SHALL BE PERFORMED BY THE
CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE GROUND
RESISTANCE FOR ALL SITES AFTER INSTALLATION OF THE EARTH GROUND
SYSTEM. A PRELIMINARY EARTH RESISTIVITY TEST (3 POLE TEST OR
CLAMP -ON -METER) SHALL BE PERFORMED PRIOR TO BACK FILLING ALL
TRENCHES AS SPECIFIED IN VERIZON NETWORK STANDARDS (NSTD46) AND
THE NATIONAL ELECTRIC CODE.
2. APPROVED MEASUREMENT METHODS FOR POST INSTALLATION GROUND
TESTING SHALL BE ONE OF THE FOLLOWING METHODS:
A. FALL OF POTENTIAL METHOD - 3 POINT
B. CLAMP -ON RESISTANCE TEST
C. TOWER AND EXTERNAL CONDUCTOR TEST
3. A GROUNDING RESISTANCE TEST REPORT SHALL BE PREPARED UPON
COMPLETION OF THE TESTING. THE TEST REPORT SHALL SHOW THE
RESISTANCE IN OHMS AT 40%, 52%, 62%, 72% AND 82% POINTS IN 10%
INTERVALS. RESISTANCE IS TO BE RECORDED AT EACH INTERVAL FOR
EACH POINT FOR FOUR (4) DIFFERENT DIRECTIONS UNTIL THERE IS A
PLATEAU SEEN AT THE 62% POINT. TESTING SHOULD BE COMPLETED IN A
MINIMUM OF TWO (2) DIFFERENT DIRECTIONS AT 90 DEGREES .APART.
RECORD THE AVERAGE OR MEAN AS THE RESISTANCE OF THE SITE AND
ENTER THIS ON THE POST RESISTANCE DATA CHART.
4. PROVIDE THE POST INSTALLATION - GROUND RESISTANCE TEST REPORT TO
THE REGIONAL PROJECT ENGINEER ACCOMPANIED BY THE POST
RESISTANCE DATE CHART.
5. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL
BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. ALL
BENDS SHALL BE MADE WTH 12" RADIUS OR LARGER.
6. APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE)
SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND
CONNECTIONS.
7. GROUNDING TEST SHALL BE TAKEN BEFORE A/C POWER, NEUTRAL/GROUND
BOND IS CONNECTED.
8. ANTI -OXIDATION CONDUCTIVE COMPOUNDS ARE REQUIRED ON ALL GROUND
CONNECTIONS. NO OX-ID (COSMOLINE GREASE BASED COMPOUND) SHALL
BE USED FOR COPPER TO COPPER CONNECTIONS. ZINC BASED COMPOUND
(GREY COLORED) OR APPROVED EQUAL SHALL BE USED FOR COPPER TO
STEEL CONNECTIONS.
9. ALL LUG CONNECTIONS & THEIR MATING SURFACES SHALL BE CLEANED
AND COATED WITH THE APPROPRIATE ANTI -OXIDIZING CONDUCTIVE
COMPOUND. IF A LUG CONNECTION IS TO BE SECURED DIRECTLY TO A
PAINTED SURFACE, THE PAINT SHALL BE REMOVED TO REVEAL BARE
METAL AROUND THE AREA OF THE CONNECTION AND COATED WITH AN
APPROPRIATE ANTI -OXIDATION CONDUCTIVE COMPOUNDS.
GENERAL NOTES
1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK
STATE BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND
ORDINANCES.
2. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL
CONDITIONS AFFECTING THE PROPOSED WORK AND MAKE PROVISIONS AS TO
THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR
FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS
AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE .ACCOMPLISHED
AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE
COMMENCEMENT OF WORK.
3. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A
DIAGRAMMATIC OUTLINE ONLY, UNLESS OTHERWISE NOTED. THE WORK SHALL
INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR
NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.
4. DIMENSIONS SHOWN ARE TO FINISH SURFACES, UNLESS OTHERWISE NOTED.
SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS
CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS
REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR
DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A
CLARIFICATION FROM THE CARRIER'S AUTHORIZED REPRESENTATIVE OR THE
ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
5. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR
MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS,
AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK.
6. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE
IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY
ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS.
7. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ALL
PRODUCTS OR ITEMS NOTED AS "EXISTING" WHICH ARE NOT FOUND TO BE IN
THE FIELD.
8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST
CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES, PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE
WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED.
9. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT
EXPERIENCED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE
BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE
AS INDICATED ON THE DRAWINGS.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA,
AND ADJACENT AREAS, THAT ARE LIKELY TO BE AFFECTED BY THE WORK
UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA
REQUIREMENTS.
11. CONTRACTOR SHALL COORDINATE HIS WORK AND SCHEDULE HIS ACTIVITIES
AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS OF THE
OWNER.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH
THE WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS
AND ANY OTHER PORTIONS OF THE WORK.
13. CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT THE OWNER
AND CARRIER.
14. INSTALL .ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OR
WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.
15. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT,
IMPROVEMENTS, PIPING, ANTENNA AND ANTENNA CABLES. REPAIR ANY
DAMAGE THAT OCCURS DURING CONSTRUCTION.
16, REPAIR ALL EXISTING SURFACES DAMAGED DURING CONSTRUCTION SUCH
THAT THEY MATCH AND BLEND WITH ADJACENT SURFACES.
17. KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS
AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY
OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION
AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE.
CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL
COMPLETION OF CONSTRUCTION.
18. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD
PRIOR TO FABRICATION AND ERECTION OF ANY MATERIAL. ANY UNUSUAL
CONDITIONS SHALL BE REPORTED TO THE ATTENTION OF THE ENGINEER.
19. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND
INSPECTIONS AND PAY ALL REQUIRED FEES.
20. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS
THAN 2-A OR 2-A/10-BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL
PORTIONS OF THE BUILDOUT AREA DURING CONSTRUCTION.
21. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP
DRAWINGS AND OTHER DOCUMENTATION SHALL BE TURNED OVER TO CARRIER
AT COMPLETION OF CONSTRUCTION.
22. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR
AFTER THE DATE OF ACCEPTANCE BY CARRIER. ANY WORK, MATERIALS, OR
EQUIPMENT FOUND TO BE DEFECTIVE DURING THAT PERIOD SHALL BE
CORRECTED IMMEDIATELY UPON WRITTEN NOTIFICATION AT NO ADDITIONAL
COST TO CARRIER.
23, RIGGING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH STATE AND
FEDERAL SAFETY REGULATIONS (OSHA). ENGINEER, CARRIER AND THE OWNER
SHALL BE HELD HARMLESS IN THE EVENT THE CONTRACTOR DOES NOT
FOLLOW SUCH SAFETY REGULATIONS.
24. CONTRACTOR SHALL PROVIDE ACCESS TO THE SITE AND ASSIST THE RADIO
EQUIPMENT VENDOR AND THE ANTENNA INSTALLATION CONTRACTOR AS THEY
MAY REQUIRE.
vverizon
I 175 CALKINS ROAD I
ROCHESTER, NY 14623
• 'Iwi
Tectonic
rRAMCA.soLmOIRL EXCEMowLLsuMOL
Tww* & w" mmuft lht, "a "Ift i tmd &awywl, O.P.C.
Project cantact Into
36 British Amerlcon Blvo. Phonr. (518) 783-1630
Suite 101 (800) 829-8531
Latham, NY 12110 www.tectomicengincefing.com
WO NUMBER DRAWN BY REVIEWED BY
12861.115 11 LPJF MP
kin Harr, Icci Tr,
0
05/06/26
FOR REGULATORY
1
06/09/26
ADDED PAINT NOTE
UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN
BEARING THE SEAL OF A LICENSED ENGINEER OR LAND
SURVEYOR IS A VIOLATION OF SECTION 7209
SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION
LAW.
COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE
OF THE SIGNATURE AND AN ORIGINAL EMBOSSED
SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF
THE PROFESSIONAL ENGINEER OR LAND SURVEYOR
SHALL NOT BE CONSIDERED VALID COPIES.
0 1
ORIGINAL SIZE IN INCHES
(22x34 FORMAT)
0 i
ORIGINAL SIZE IN INCHES
(11x17 FORMAT)
ROOD &RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
UTILITY POLE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
GENERAL NOTES
SHEET NUMBER
13# NORTH ORIENTATION
N 7l 1. NOR 4 H ORIENTATIO'J ESTABL ISId ..0 N
BY COMPASS OBSERVATION!.
EDGE OF EXISTING—.,
PAVEMENT
,IIF1 1`�
<
'C'
O
41
�.
o
y.
♦ , � F its
r ! A
t�w M
C.
Ir
1 EXISTING OVERHEAD
, ► / ' WIRE (TYP)
d .. .
\
yf) # /
t +� C' PROPOSED VERIZON WIRELESS EQUIPMENT ON
PROPOSED UTILITY POLE. NEW POLE TO \
t REPLACE EXISTING UTILITY POLE #NM 17/VZ 15 \
1
e r
s ir; do ` �— EKSTI Nt U11LITY
POLE `TIP) R
NOTE:
SITE IN- ORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING
CONSULTANTS, GEOLOGISTS & LAND SURVEYORS D.P.C., OIJ 11 /10/25.
1 SITE PLAN
1" - 8"" (11x17 S12E)
1- = 40' (22x34 S17E)
EXISTING UTILITY POLE TO
BE REMOVED & REPLACED
EQUIPMENT PLAN
C-1 SCALE: 3/4' = 1•-0" (11x17 SIZE)
1 1/2" - (22x34 SIZE)
PROPOSED VERIZON WIRELESS
EQUIPMENT SHROUD WITH PROPOSED
RRH AND ASSOCIATED EQUIPMENT
(SEE DETAIL 5/C-3)
PROPOSED FUJITSU PASSIVE -
FIBER ENCLOSURE MOUNTED
TO EXTERIOR OF SHROUD
PROPOSED VERIZON WIRELESS
1" FIBER CONDUIT
PROPOSED 1-1/2" CONDUIT
(FROM SECONDARY TO METER)
PROPOSED
UTILITY POLE
3 SHROUD PLAN VIEW
` SCALE; 3/4" = 1'-0" ('tx,7 SIZE)
1-1/2" = 1•-0" (22x34 SIZE)
PROPOSED #2
VERTICAL GROUND
1-1 /2"
(FROM
RY TO METER)
--PROPOSED
METER
PROPOSED #2
VERTICAL GROUND
-PROPOSED
100A LOAD
CENTER
DPOSED 1-1 /4"
RISER FOR AC
C`I IITq Tn gHRni In
-GUARD FOR
ANTENNA
verizon
175 CALKINS ROAD
11 ROCHESTER, NY 14623
Tectonic
PRAC"i SOMC .
Te,_tone E4%MWA0ComAwta, 090bolb ! Land %-wtom, "-.-
Project ca":-tact Into
36 8r-tlwh Amerizon BlvC Phorn. '5'8) 7,43-1630
SJ;te 10' {900) 82.9-6531
Latnam, NY 12110 »wwAezt3mcengincerngxom
NO NUMBER DRAWN BY REVIEWED BY
12861.115 LP MP
kin 11A= ICCI IC
0
05/G6/26
FOR REGULATORY
1
05/D9/26
ADDED PAINT NOTE
pF A` j
UNAUTHORIZED AL =RATION CR ADDITIONS TO A PLAN:
BLARING THE SEAL OF A LICENSED ENGINEER OR LAP:D
SURVEYOR IS A VIOLATION OF SECTION 7209
SUED -
VISION 2 OF THE NEW YORK STATE EDUCATION
u.w.
COPIES OF THIS DOCUMEN' VlrTHOUT A FACSIMILE
0= THE SIGriATLRE AND AN: ORIGINAL EMBOSSED
SEAL OR OR;GINAL STAMP IN BLUE OR RED INK OF
THE PROFESSIONAL ENGINEER OR L-.'JD SURVEYOR
SHALL NOT BE CONSIDERED VALID COPIES-
0 1
ORIGINAL SIZE IN INCHES
(22x34 FORMAT)
0
ORIGINAL SIZE IN INCHES
(11x17 FORMAT)
SITE INFORMATION
ROOD & RIDDLE
FUZE IDS: 17612418
MDG#: 5000993724
511E ADDRESS
UTILITY POLE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
SHEET TITLE
SITE PLAN & EQUIPMENT
PLAN
SHEET NUMBER
Cw�l
SUMMARY OF MAKE READY WORK
1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC
MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS.
2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH
TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450)
3. REPLACE SPAN OF NEUTRAL TO P18 1MTH 250' OF 1/0 TPX.
4. ATTACH TPX AT 31'6".
5. REPLACE SEC BRACKETS (NG 10-101 FIG 5).
6. REPLACE PRI DG (NG 3-105).
7, INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE.
NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK.
CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION
STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT
SPECIFICATIONS.
LICENSE APPLICATION BROOD & RIDDLE/MDG:5000993724
WORK REQUEST ##30352102
t�
F
4 ...•
I•
ti
,
z •
,
1 EXISTING POLE PHOTO
C-2A SCALE: NTS
EXISTING PRIMARY ELECTRIC
34.0'± AGL \
TOP OF EXISTING UTILITY POLE
33.2'± AGL
EXISTING PRIMARY ELECTRIC
_
31.3'± AGL
EXISTING DOWN GUY WIRE IX
30.0'± AGL
EXISTING PRIMARY ELECTRIC
LINE TO BE RELOCATED PER
NATIONAL GRID REQUIREMENTS
(SEE 3/C-2A)
EXISTING PRIMARY ELECTRIC
CROSSARM TO BE REMOVED &
REPLACED PER NATIONAL GRID
REQUIREMENTS (SEE 3/C-2A)
R_
- EXISTING SECONDARY ELECTRIC
LINE TO BE RELOCATED PER
f NATIONAL GRID REQUIREMENTS
EXISTING SECONDARY
(SEE 3/C-2A)
26.3'± AGL
EXISTING DOWN GUY TO
BE REMOVED & REPLACED �
-- EXISTING COMM LINE TO BE
r1h EXISTING FIBER LINE
�
✓% RELOCATED (BY OTHERS)
22.7 ± AGL
EXISTING DOWN GUY WIRE
EXISTING COMM LINE TO BE
22.7'± AGL
RELOCATED (BY OTHERS)
EXISTING COMM LINE
22.0'± AGL
EXISTING UTILITY POLE
#NM 17 /VZ 15 TO BE
REMOVED & REPLACED
EXISTING GRADE
STREET SIDE
2 EXISTING UTILITY POLE ELEVATION
C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE)
3/8" = 1'—O" (22x34 SIZE)
19"
TOP �OF PROPOSED UTILITY POLE REPLACE PRIMARY
38.5 ± AGL / CROSSARM WITH NG 9-450
RELOCATED PRIMARY
36.5'± AGL-�
NEW/REPLACEMENT DOWN GUY WIRE
35.2'± AGL
NEW REPLACEMENT SECONDARY
31.5'± AGL
RELOCATED FIBER LINE
MR-) 25.0'± AGL
r
rik
RELOCATED DOWN GUY WIRE %
25.0'± AGL
-0RELOCATED COMM LINE
-24.0 ± AGL
REPLACE PRI DG (NG 3-105).
INSTALL SEC DG (NG 3-118)
CONFIRMED ON EXISTING THIMBLE
REPLACE SPAN OF NEUTRAL TO
P18 WITH 250' OF 1/0 TPX.
ATTACH TPX AT 31'6". REPLACE SEC
BRACKETS (NG 10-101 FIG 5)
COMM/FIBER REATTACHMENTS TO
BE DONE BY OTHERS (BY OTHERS)
EXISTING UTILITY POLE
#NM 17 /VZ 15 TO BE
REMOVED & REPLACED
EXISTING GRADE
i
STREET SIDE
3 PROPOSED UTILITY POLE ELEVATION
C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE)
3/8" = 1'—O" (2204 SIZE)
'verizon
1 175 CALKINS ROAD
ROCHESTER, NY 14623
la
Tectonic
FRACMAL sousnmca.
Tat*m EmOw" Co mAmts, Codogisr i lad Uwwp s, Q.P.C.
Proj. ? Gamut Info
36 British Amorleon Blva. Phor: (518) 783-1G3.9
Suiv
te 101 800 829-6531
Latham. NY 12110 www.to&-onicengineering.com
WO NUMBER DRAWN BY REVIEWED BY
12861.115 LP MP
Alf% r%ATC ICCIIC
0
05/06/26
FOR REGULATORY
1
06/09/26
ADDED PAINT NOTE
UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN
BEARING THE SEAL OF A LICENSED ENGINEER OR LAND
SURVEYOR IS A VIOLATION OF SECTION 7209
SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION
LAW.
COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE
OF THE SIGNATURE AND AN ORIGINAL EMBOSSED
SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF
THE PROFESSIONAL ENGINEER OR LAND SURVEYOR
SHALL NOT BE CONSIDERED VAUD COPIES.
0 1
ORIGINAL SIZE IN INCHES
(22x34 FORMAT)
0 1
ORIGINAL SIZE IN INCHES
(11x17 FORMAT)
SITE INFORMATION
ROOD & RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
SITE ADDRESS
UTILITY PO LE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
MAKE READY SCOPE OF
WORK
C-2A
NOTE:
USE OF SCHEDULE 40/80 CONDUIT OR
RIGID CONDUIT SHALL BE DETERMINED BY
THE UTILITY PROVIDERS REQUIREMENTS.
PROPOSED 4G ANTENNA
(SEE DETAIL 1 /C-3)
PROPOSED POLE TOP ANTENNA
MOUNT (SEE DETAIL 1 /C-3)
INSTALL RF "CAUTION" SIGNAGE 2't BELOW
PROPOSED ANTENNA (SEE DETAIL 4/C-3)
PROPOSED WEATHERHEAD FOR POWER
(CARLON P/N: E99SH-CAR OR APPROVED EQUAL)
PROPOSED COAX CABLES TO
ANTENNAS IN 4" MAX U-GUARD
PROPOSED MOPT TERMINAL -
(BY OTHERS)
PROPOSED LC/UPC BIDI RUGGEDIZED FIBER -�
JUMPER FROM THE PROPOSED MOPT
TERMINAL TO PROPOSED FUJITSU PASSIVE
FIBER ENCLOSURE WITHIN 1" CONDUIT
PROPOSED VERIZON WIRELESS -
EQUIPMENT SHROUD WITH PROPOSED
RRH & ASSOCIATED EQUIPMENT
(COMMSCOPE PN: SSC-760249586X1 X
OR EQUAL) (SEE DETAIL 5/C-3)
PROPOSED 1-1/4- PVC RISER FOR -
AC CIRCUITS TO SHROUD
PROPOSED EATON BRP12B10OR LOAD CENTER
OR APPROVED EQUAL (SECURE TO POLE
USING UNISTRUT OR APPROVED
MANUFACTURER RECOMMENDED HARDWARE)
PROPOSED RF "INFORMATION" -�
SIGNAGE (SEE DETAIL 4/C-3)
PROPOSED METER MILBANK P/N: U2048-RL OR-/
APPROVED EQUAL (SECURE TO POLE USING
ERICKSON SERIES PBAL MOUNTING BRACKET OR
ELECTRIC COMPANY APPROVED EQUAL)
TOP OF PROPOSED ANTENNA
41.7'f AGL
- - --- --q PROPOSED ANTENNA- ---- --- -- - -
40.7'f AGL
TOP OF EXISTING UTILITY POLE
38.5't AGL
MIN
EXISTING PRIMARY
36,3't AGL
EXISTING SECONDARY
31.5'± AGL
- PROPOSED 1-1 /2" PVC RISER FOR POWER
EXISTING GUY %"v'IRE
75.Ci't AGL
EXISTING FIBER
25.0't AGL
EXISTING C01�/IMUNICATION
�4.0'+ AGL
BOTTOM OF PROPOSED MOPT TERMINAL
21.7'f AGL
PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE
MOUNTED TO EXTERIOR OF SHROUD
Y2
C-2E
BOTTOM OF PROPOSED EQUIPMENT
12.0'f AGL (MINIMUM)
_ BOTTOM OF PROPOSED LOAD CENTER
10.0't AGL (MINIMUM)
BOTTOM OF PROPOSED METER
8.0't AGL (MINIMUM)
BOTTOM OF PROPOSED RF SIGNAGE
8.0't AGL (MINIMUM)
- EXISTING UTILITY POLE
PROPOSED HIGH IMPACT -
PVC CABLE COVER (BLACK)
EXISTING G)\ADF
i
1 UTILITY POLE ELEVATION
-28 SCALE: 3/16" = 1'—u" (11x17 SIZE)
3/8" = V-0" (22 x34 SIZE)
EXISTING GRADE
0.0'f AGL
PROP(
TERMINAL (E
PAINTING NOTE: ALL
PROPOSED EQUIPMENT
SHALL BE PAINTED BROW
XISTING FIBER LINE
XISTING COMIM LINE
)POSED VERIZON WIRELESS
U-GUARD (CABLES FROM
I TO ANTENNA)
)POSED LC/UPC BIDI RUGGEDIZED
:R JUMPER FROM THE PROPOSED
:IT TERMINAL TO PROPOSED FUJITSU
3SIVE FIBER ENCLOSURE
►POSED VERIZON WIRELESS EQUIPMENT
OUD (COMMSCOPE PN: SSC-760249586X1 X
EQUAL) (SEE DETAIL 5/C-3)
)POSED 1-1/2" CONDUIT
OM SECONDARY TO METER)
OPOSED RUGGEDIZED FIBER JUMPERS TO
Hs AND MMUs IN THE SHROUD (TYP OF 2)
?OPOSED EATON BRP126100R
)AD CENTER OR APPROVED EQUAL
IN OPPOSITE SIDE OF POLE)
OPOSED 1-1/2" LIQUIDTIGHT
ETER TO LOAD CENTER)
PPOSITE SIDE OF POLE)
'OPOSED METER MILBANK P/N:
048-RL OR APPROVED EQUAL (SECURE
POLE USING ERICSSON SERIES PBAL
)UNTING BRACKET OR APPROVED EQUAL)
`- EXISTING UTILITY POLE
ELEVATION DETAIL
—2B
SCA'_L: 2" = 1'-0" (11x17 SIZE)
1" - 1'—O" (22x34 SIZE)
verizon
"i 75 CALKINS ROAD I
it Pr)rrESTER, NY 14623
i
flectonic
..AmuL,SOLUTIoR&EXUP"ON LS.RVICE.
T.etd E/+okiew10 Cenartw* Gedogletr t Lane 5lrwyon, Q.P.C.
rrojsct Cc^loci info
36 bnt%eh American 81vc. Phore- (5'8 783-1G3J
S J'te 101 ,800 829-6531
Lulhom. NY 12110 www.tectoricengmeenng.com
WO NUMBER DRAWN BY REVIEWED BY
12861.115 LP P
kin MATT Icc11c
C
05/06j26
FOR REGULATORY
1
0o/C9/26
ADDED FAINT NOTE
UNAUTHORIZED ALTERATION OR ADDIT5ONS TO A PLAIT
SEARING THE SEAL OF A LICENSED ENGINEER OR LAND
LRVEYOR IS A VIOLA"ION OF SECTION 7205
SUED -VISION 2 OF T-Ic NFiV YORK STATE EDUCATION
L' IV,
COPIES OF THIS DOCUMEM WITHOUT A FACSIMTF
0= THE SIGNATURE AND AN ORIGINAL EMBOSSED
SEAL OR ORIGINAL STAMP IN BLUE OR ZED INK OF
THE PROFESSIONAL ENGINEER OR L-.ND SURVEYOR.
SHALL NOT 3E CONSIDERED V UD COPIES_
0 1
ORIGINAL SIZE IN INCHES
(22x34 FORIVAT)
0
ORIGINAL SIZE IN INCHES
(11 x17 FORMAT)
SITE INFORMATION
ROOD & RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
SITE ADDRESS
UTILITY POLE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
SHEET TITLE
POLE ELEVATION & DETAIL
SHEET NUMBER
ANTENNA (JMA P/N:
CX160M1236—BF22)
IA MOUNT SLEEVE (GIMBAL)
ALFAB P/N: 900070)
'OLE MOUNT BRACKET
CONCEALFAB P/N: 007951
)R APPROVED EQUAL)
TILITY POLE 0 TO
tJE VERIFIED IN FIELD
POLE —TOP ANTENNA MOUNTING
"-3 SCALE: %T3
I` A CAUTION A
Transmitting Antenna(s)
Radio frequency fields beyond
this point MAY EXCEED the FCC
Occupational exposure limit.
Obey all posted signs and
site guidelines.
Call Verizon at 1-800-264-6620
PRIOR to working beyond this
point.
Site ID/ PSLC:
verizon •`
ACTIVE COMMUNICATION EQUIPMENT
u1►+JIUYAPR0004t W74i M FT FfOtR2r31iTJILA>tD R V1ERTtf,•1
POMP VON%AkT[hM BY VT7<AM DWOWOMT MTR} OR CALL
v [ Iambi V nRE'. E 55 rOR PMR a•aTT001M V44E EVER APPROACHW#
"TrViA1ao" _rt 1lOKITIUTALAtq�FT VUMCAI
PIAAK CA- L tEF. Z0M WI R 3 S FT 1-I114l- 4QG FRl01l To
CFfrtSTlr,G : �C _hVEGT �:�'C-
NOTE:
1. CONTRACTOR TO FURNISH AND INSTALL PHENOLIC
LABEL APPLIED TO LOAD CENTER.
2. ATTACH R:Y "CAUTION" AND "INFORMATION" SIGNAGE
TO FACE OF UTILITY POLE USING 1'r WOOD SCREWS.
3. RF SIGNS ARE APPROXIMATELY 6"0.5" IN SIZE.
- PROPOSED SIGNAGE
SCALE: NTS
POLE MOUNTING BRACKET —�
(ERICKSON P/N: PBAL-12 OR
APPROVED EQUAL) (TYP OF 2)
/ e
r� -mil
,p
1p- 1 /4%1" WOOD SCREW
(TYP OF 4/BRACKET)
S.S. 1/4"-2Ox3/4" CARRIAGE BOLT,
FLAT WASHER, & NYLON LOCK NUT
(INCLUDED WITH BRACKET)
PROPOSED METER SOCKET,
MILBANK P/N/ U2048—RL (OR
APPROVED EQUAL CONFORMING TO
UTILITY COMPANY STANDARDS)
METER MOUNTING DETAIL
C-3 SCALE: NTS
Metro Cell Solutions COMMSC�- PE
SSC-760249586X1X
MV2 Micro Radio Concealment Enclosure
Universal Single Part Number Radio Enclosure
Introduction
One pale mou led Ratio Er c i . - •, re fr r a U ywr radio
moons under a siroE Dan r, UiTlt er
Hpfty contigurabde - swports varyrng
conrigurations with a unhwwl mounting t
solution
• Aesftlicaa0F awwad trout `
r.
• Accepts Rados Iron: •
Ericssw radios SSC-760249586EIX
Nokia radios SSC-760249586N i X
Samsung ra(hos SSC-760249586S 1 X �
Th= raoic __. ceairrler! e :cf^_ silpl su-e 1= deed to
coriia +ea! smaj: cell -e ni " Jr-Te'd 10 wisl 1A
MCiiJ) LOT..(C:C. i)1)., iS'_ _ Ili Al. --tJ'CS 81i wd ai
vale replan ernerlts wrterc ,; _ :il Impact tt
desired-
UniQue, ant-.emaI internal rr•wunting s-,s,em
• Can he k;tted with Rec6-5erz CorrrnScoCe
diF.wexers and jumpers
System Dimensioning & Configuration
-:. i•__ ..-.- n�-!� -.!..i-. -iti •=i. ll«'".. :-rtr-, •tJ jr .i.�;F. ri+i;,i .._ , .C.. :.. its•. 1+._'; ._ i-
1041b► f43►_+]I with rip fifdC efx:,QFMrY. ,-'I•.;
S;:t--, ;`.,i�'4 Approx 479tt 1276kgliciytoeded' (maxi
•weipW vaned on oofilguraeon
LAn. ,, Max f..:,ilrCattle Poia 00 2.5ira85 in 00 by ciarnIpr4 (Lwgrr dionew pales by steell bardtng)
Mth het ded MWr&V kt) Up to 121n DID Wood Ada with irm:Jitded 511l- ftreaded rod for ttr k* booing
UV-resntao powder eoaL Vanouc eako o0o is a, ailae!a
Finish 'I- for Ligm Gary. -Y for Green -3- for 84m*, --C for Brown W fcw Fa)rfax Brown -F
Federal Park Brown. 'T for hietaa"c SNw "W for W hte
Bik-A 1-2) 2' Trade Sire Knockouts
Paver: Fiber input Corduii Bat: (2) I Trade Saa KnockocRs
Top: (2 ) 2' Trade Size Knockouts
MC-SP-RENT-21-001-M
NOTE:
USE OF SCHEDULE 40/80 CONDUIT OR
RIGID CONDUIT SHALL BE DETERMINED BY
THE UTILITY PROVIDERS REQUIREMENTS.
UTILITY POLE -�
r'rCUt-UJ V Ghi t UN Dlzr- I LE
ELECTRIC PANEL OR APPROVED E
PROPOSED 1 /4%20 3/4"
LONG BOLT (TYP OF 3)
PROPOSED P1000T —
UNISTRUT 6" LONG
(TYP OF 2)
PROPOSED 1
CHANNEL NUT (TYF
PROPOSE[
L�
3 LOAD CENTER MOUNTING DETAIL
SCALE: 4- = 1'-0" (11x17 SIZE)
= 1•-0" (22x34 SIZE)
Metro Cell Solutions COMMSC,. PE
Ericaeon CordiOurations
• (2) RRU1 VRRU!32R212s44154s2&4478 b (i) PSU AC OZW unim
• (118843 or 4449 Dual Band RRU 6 t2) PSU AC 02'Oa units
• (1) 9843 and (1) 4478 & (3) PSU AC 02V units
• (1) 4415_ (1) 444{1 wid (1) 220%440x i (3) PSU AC 02'DB units
• (1) 4455 and (1) •44413 d. 4 3) PSU AC 02.1% :slits
• (1) 4440 and (2) 220x-440s 8121 PSU AC 0204 Lauts
• Up to (61 Zn&K22052206 or 4402 440B radios
• (1) 4415 or 4426 radea and (1) 220x$440x a (1) PSU AC 02i08
"I'Li tine Corrtpatibiltty for plot 320W C-Band Radio '•
• 11 r 8863 a--.J I 1 I cN S-. a•r 11) 444y (4 ) PSU ACO8,11) (1) :SOX 19=-43 811) Raycap
se "PTease e Ccrrtnscgpe for additionaf wriigurabom -
sa--m Co"Norrad—
• 01 or (2) 70Q'1l50 32M oval bard radio. t 1 r RT4401-48A CBRS radio. (1) RT2201-
46r1 LAA rA io, 0 l c1r (2b Dots 2 dk W DC rectifier. (1) SOX 1 o2f Q4W SDx 1426T-43
and (1) Raycep
e 11) AWS+PCS AWS.'PCs 32OW dual band rode 11) RT4441.4aA CBRS radio. 01
RT2201j46A LAA radio, (1) Debts 2.0kW DC rectifier, (1) SOX11i260-43r SDX1926T-
43 and (1) Rsycao
• 111 AWS-PCS or 7W.'85O 32OW duo ber-4 radio. 0116OW dual band radio (1)
RT4401-48A CBRS radio. (1) RT2201-46A LAA radio. (1) or (21 Deu 20kW DC
Racko, Cow"Itibil-dy rtcilf w. t t l SDX 1926U-43r SDX192UT-43 arxi 11) Raycap
SSC-760249S86XIX . 11) or (2) 16OW dual band ratbm (1) RT4401-46A CBRS radio. (1) RT-701 -6A LAA
todlo. (1) or iZ) Deka 2.OkW DC rechW (1) 9DX 19260-4N SDX 1926T-4 3 t 1 !
Rayow
"PifCa-4ns--qr1r, rrprrsar AhV roradxfirtr:ar CO 5gnf ildOf s-
Nokia Coefiprodons
• 14) A scale Micro rziaim
• 12) Dual Band Radios- 7&)VV and 320W phis tschfws
S,upporfed dual band radios.
"AHFiA "AHFIS "AHFIC '-AHLBA "AP48C.A "AHRCC "Al4 BBA
supported Rectifiers,
"Dolts "GE "CCI "Ndur FPAE
**Pk;arrtr see Cormrrscnpr+ re6paisenri im far additional cn6gtmatiorss-
tf
• es-�os.re Ac runw mho Vo eornsa,c warts "=MI i
asc�.:-as.v-.az-r•�rscx-f►rs>•_i�.r:.c•v �3.�:a,:
• Ervvclt: car.:CrxprWaare C3r.►-s-_uor D M4e - llwx to -.SOX Mloc 43. 3Ct t?2CT.[1
• E,-:;,as rr rye: :oormwwn 0"W 194W t f w OF., rink reCW%M a CCI .screres, chi tecottM OR
!•>•tle FPAE-acomwa.- rumor see rrnee�cr.�e r0PT2W 0&V* to dea t
• 'x' 0W.4es i0Q-- -$ -roi LVII Glra. '.r +a Greer: -3- yr e.KA -4- F anfar erc•rt. T-
F.eoe•a Pee sMW&. T tar Tar ''Al"r
i
�x
MC-SP-REMI-21-003v04
r EQUIPMENT SHROUD DETAILS
S•..l,'�: NTS
SHOWN MOUNTED ON AN g'o POLE
CLAMP. STRAP. AND THRU BOLT OPTIONS
s.0 , t3.0 �, l jI (2) 2 TRADE SIZE KNOCKOUTS FOR CABLE ENTRY/
EXIT (CROSS CUT RUBBER GROMMETS INCLUDED)
T-`• — RJLLY VENTED WITH GR487
+ COMPLIANT PERF PATTERNS
-tr f .
�J
i
UNIVERSAL POLE—? REMOVABLE
24_Ll MOUNTING BRACKET Pi4NEL ACCESS
3-3
di
��777,
y t-3
048.E
TAtitPE? RESISTANT LATCH f ." _...Y-�...
WITH PADLOCK HASP K 7' TRADE SIZE �
KNOCKOUTS
• ' �(?) 7 TRADE SIZE
KNOCKOIJk,
TAMPED. RESISTANT
MTO SCREWS
4.0.—
� � --r-• •-•• SSC-760249%6X1X
3:5747 11{ i METROCELL RADIO CONCEALMENT
-- !
6�.�r.V.E�;: A 1 CoMMSCC*APE
. . • I— -- - ---
verizon
1 175 CALKINS ROAD I
ROCHESTER, NY 14623
ectonic
PRArnuu SOLUTlottls. axatrr ON LL5111MCL
Tectonic Enlmav ig Conu *-(t , Geologists • tmd Suvgors, D.P-C.
Frnj•ct Cup-focf Info
36 86tish Amerl=n Blva. Fhone: (5'f3 783-1630
Suits 101 (800� 829-6531
Latham. NY 12110 www.tectomicengineen-ng.com
WO NUMBER DRAWN BY REVIEWED BY
12861.115 LP I MP
NO. DATE ISSUE
0
05/06/26
FOR REGULATORY
1
06/09/26
ADDED PAINT NOTE
I
UNAUTHORIZED AL ERATION uR ADDI?!ONS TO A PLAN
BEARING THE SEAL OF A LICENSED EfGINEER OR LAND
SLR'v?YOR IS A VIOLATION OF SECTION 7209
SLED VISION 2 OF THE NEW YORK STATE EDUCAi1ON
LA'r1'-
COPIES OF THIS DOCUMENT yi1THCUT A FACSIMILE
OF THE SIGNATURE AND AN ORIGIMA'_ -EMBOSSED
SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF
THE PROFESSIONAL ENGINEER OR LAUD SURVEYOR
SHALL NOT BE CONSIDERED VALID COPIES.
01
1
ORIGINAL SIZE IN INCHES
(22x34 FORI'',:AT)
0
ORIGINAL SIZE IN INCHES
111 x17 FORMAT)
SITE INFORMATION
ROOD & RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
SITE ADDRESS
UTILITY PO LE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
ANTENNA MOUNT GROUNDING -,
CONDUCTORS. #6 AWG STRANDED, ,
INSULATED AND COPPER CABLE,
SECURED TO POLE AND ANTENNA \
MOUNT USING UV RATED CABLE TIES
ANTENNA GROUNDING CONDUCTORS. #6
AWG STRANDED, INSULATED AND COPPER `y
CABLE, SECURED TO POLE AND ANTENNA
MOUNT USING UV RATED CABLE TIES
PROPOSED VERIZON
WIRELESS ANTENNA
BOND MAIN GROUND TO NEUTRAL
WIRE OF SECONDARY TRIPLEX
PROPOSED INSULATED
P-CLIPS/STRAPS OR
E STAPLES PLACED 18" APART
p�
i
PROPOSED HOME RUN GROUND- ' - PROPOSED
WIRE, #2 AWG COPPER MOPT TERMINAL
INSULATED OR #2 TINNED ' (BY OTHERS)
PROPOSED -
EQUIPMENT
SHROUD
PROPOSED
LOAD CENTER
PROPOSED METER
#6 AWG INSULATED GROUND TO
HOME RUN FROM ALL CABLES
AND METALLIC OBJECTS
PROPOSED 1 /2" HIGH IMPACT PVC
U—GUARD (U—MOLDING) MOLDING
TO COVER GROUND DOWN WIRE
ALONG BOTTOM 8' OF POLE
EXISTING GRADE
-- c
M
„
PROPOSED GROUND ROD (TYP OF 2)
3 _
(SEE DETAIL 3/E-1)
's
z
s
s"
s
1- 011
UTILITY POLE GROUNDING DETAIL
E—, SCALE: 3/16" = 1'-0" (1107 SIZE)
3/8" = 1'—O" (22x34 SIZE)
Q
z
z
w
z
COAX GROUND- �¢ - ANTENNA MOUNT
KIT (TYP) �=
__ --COMPRESSION CONNECTION
BY CONTRACTOR (TYP)
;I
I
- SECONDARY
i
II
I
'i
I I
'
'I
'
'I
I
PROPOSED
CALIBRATION CABLE
I
ANTENNA COAX JUMPERS
I
(TYP OF 16) ' i
- - - - - - - - - -
'---
-- --I----- - SMALL CELL
C-BAND RRH
I
POWER
'
I MODULE
��---
I
-- -F-- - HI -BAND
GROUND BAR WITHIN SHROUD
DOUBLE C-TAP OR COLOR CODED -�
LONG BARREL DOUBLE LUG
CONNECTION WITH NON OXIDIZING
COMPOUND (TYP)
#6 AWG INSULATED GROUND TO
HOME RUN FROM ALL CABLES
AND METALLIC OBJECTS
HOME RUN GROUND WIRE,
#2 AWG COPPER
INSULATED OR #2 TINNED
RRH
r POWER
.4
MODULE
I
LOAD
CENTER
0
METER
SOCKET
GRADE ,
GROUND ROD (TYP)
GROUND LINE #2 AWG COPPER
GROUNDING RISER DIAGRAM
E-1 SCALE: NTS
PROPOSED 100A METER SOCKET
(MILBANK P/N: U2048-RL OR
APPROVED EQUAL BY UTILITY PROVIDER)
100A METER BY
UTILITY PROVIDER �.
P P
1-1/2" CONDUIT W/ (3)# 1. CONTRACTOR
TO ROUTE CONDUIT TO THE HEIGHT OF THE
SECONDARY OHW AND SPOOL 10' OF
CONDUCTOR ABOVE THE. CONDUIT. SPLICE
TO SINGLE PHASE SERVICE TO BE r
PERFORMED BY UTILITY PROVIDER.
CONTRACTOR TO UTILIZE PENETROX -'
--e0
--Z 0
EQUIPMENT
SHROUD
-54DC CABLE
r
1
120/240V
SUPPLY CABLE
(TYP)
PROPOSED VERIZON 1IRELESS ' nn n
LOAD CENTER (EATON
BRP1281
1 1 /2" C W/ (3) #1
P P P
(OR APPROVED EQUAL) ON ALL ONE LINE DIAGRAM
CONNECTIONS WITHIN METER SOCKET 5
E—, SCALE: NTS
\DE
)THERMIC WELD (TYP)
GROUND ROD, COPPER
CLAD STEEL ROD, MIN
5/8" DIA. X 8'-0" LONG
(TYP OF 2)
n Y
6' MIN
NOTE:
GROUND ROD SHALL BE DRIVEN VERTICALLY,
NOT TO EXCEED 45 DEGREES FROM VERTICAL.
GROUND ROD DETAIL
E-1 SCALE: NTS
NEUTRAL
BONDING SCREW
PROPOSED LOAD CENTER
(EATON P/N: BRP1213100R)
PROPOSED GROUNDING ELECTRODE
CONDUCTOR. #2 AWG STRANDED, INSULATED
COPPER CABLE TO GROUND BUS
LOAD CENTER GROUNDING
E—� SCALE: NTS
PROPOSED SMALL CELL -�
C-BAND MMU
(1) DC CABLE (DELTA P/N - ,}
3799423700-S)
s
r- (1) AC CABLE (DELTA
/ P/N 3799919300-S)
RRH
DELTA ADVANTAGE P
P -� P AC/DC MODULE
PROPOSED -�
HI -BAND RRH ti
DELTA ADVANTAGE
P P AC/DC MODULE P RRH
L (1) AC CABLE (DELTA
P/N 3799919300-S)
(1) DC CABLE (DELTA P/N
3799423700-S)
verizon
175 CALKINS ROAD I
ROCHESTER. NY 14623
Tecton'i*c
nArnnci
,o*w ""W*q owl~ "dag A t toga Urw om D.P.c.
Ffo;.ct Canted Info
36 Brltieh Ar ericon Blvd. Phone: (518) 783-1630
Suite 101 (800) 829-6531
Latham. NY 12110 www.tectomicangincering.corn
WO NUMBER DRAWN BY REVIEWED BY
12861.115 LPIF MP
AIA IIATC MCI IC
0
05/06/26
FOR REGULATORY
1
06/09/26
ADDED PAINT NOTE
UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN
BEARING THE SEAL OF A LICENSED ENGINEER OR LAND
SURVEYOR IS A VIOLATION OF SECTION 7209
SUBDIVISION 2 OF THE NEYV YORK STATE EDUCATION
LAW.
COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE -
OF THE SIGNATURE AND AN ORIGINAL EMBOSSED
SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF
THE PROFESSIONAL ENGINEER OR LAND SURVEYOR
SHALL NOT BE CONSIDERED VAUD COPIES.
0 1
ORIGINAL SIZE IN INCHES
(22x34 FORMAT)
0 1
ORIGINAL SIZE IN INCHES
(11 x17 FORMAT)
ROOD &RIDDLE
FUZE ID#: 17612418
MDG#: 5000993724
UTILITY POLE# NM 17/VZ 15
ALONG HENNING RD
CITY OF SARATOGA SPRINGS
SARATOGA COUNTY
NY 12866
SHEET TITLE
ELECTRICAL & GROUNDING
DIAGRAMS & DETAILS
SHEET NUMBER
E�l