Loading...
HomeMy WebLinkAbout20260521 Henning Rd Verizon Utility Pole ApplicationTransaction Record Fedla, TRACKING NO.: SHIP DATE: ESTIMATED TOTAL COST: 873503251603 Jun 24, 2026 33.73 USD From address Lisa Krutka YOUNG SOMMER LLC 500 Federal Street, 5th Floor FI 5 12180 NY TROY US Phone:5184389907 lkrutka@youngsommer.com To address Mark Graham, Admin. Asst. APED City of Saratoga Springs 474 Broadway 12866 NY SARATOGA SPRINGS US Phone:5185873550 Package information Pieces Weight Dimensions (LxWXH) Carriage value Package options 1 x 1.00 lb nla Packaging type: Service: Pickup l drop-off type: FedEx Envelope FedEx Nacional 1 0:30 a.m. I have already scheduled a pickup at my location Billing information Bill transportation cost to: ******419 P.O. No.: Bill duties, taxes and fees to: Invoice No.: Your reference: 11889.57 & 11889.96 Department No.: Please note: This transaction record is neither a statement nor an invoice, and does not confirm shipment tendered to FedEx or payment. FedEx will not be responsible for any claim in excess of $100 per package, whether the result of loss, damage, delay, non -delivery, misdelivery, or misinformation, unless you declare a higher value, pay an additional charge, document your actual loss and file a timely claim. Limitations found in the current FedEx Service Guide apply. Your right to recover from FedEx for any loss, including intrinsic value of the package, loss of sales, income interest, profit, attorney's fees, costs, and other forms of damage whether direct, incidental, consequential, or special is limited to the greater of $100 or the authorized declared value. Recovery cannot exceed actual documented loss. Maximum for items of extraordinary value is $1000, e.g., jewelry, precious metals, negotiable instruments and other items listed in our Service Guide. written claims must be filed within strict time limits; Consult the applicable FedEx Service Guide for details. The estimated shipping charge may be different than the actual charges for your shipment. Differences may occur based on actual weight, dimensions, and other factors. Consult the applicable FedEx Service Guide or the FedEx Rate Sheets for details on how shipping charges are calculated, Young. Sommer,.-,.,._,.-, ATTORNEYS AT LAW MAIN OFFICE (FOR ALL MAIL): Soo FEDERAL STREET, 5TH FLOOR, TROY, NEW YORK 12180 ALBANY OFFICE: 41 STATE STREET, STE 604-12, ALBANY, NEW YORK 12207 Phone: 518-438-9907 o Fax: 518-438-9914 www.youngsommer.com June 24, 2026 Vial Feder -a 11 Mark Graham Administrative Assistant for OPED City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866 David C. Brennan, Esq. Writer's Telephone Extension: 224 dbrennan@youngsommer.com RE: Cellco Partnership d/b/a Verizon Wireless Application for DRB Approval Utility Pole No. NM 17NZ 15 — Along Henning Rd. Dear Mr. Graham: Please find enclosed an application to the Design Review Board for a proposal to add a wireless small cell antenna and equipment to a replacement utility pole in the public right of way. Also enclosed is a check in the amount of $650.00 for the application fee. We look forward to discussing this further with the Design Review Board at an upcoming meeting. In the meantime, if you have any questions concerning this letter or the enclosed materials, please contact me at your convenience. Very truly yours, Z i David C. Brennan, Esq. Encl. DESHGI\\J ► EVHEW BOARD CHT"Y OF SARATOGA SPRINGS, S RATOGA COUC \\\ITY,N_I W'`i1ORK In the Matter of the Application of C EELLCO Pl\I,�1RT INE RS HP dyb/a-�Ve:inzo W Lre ess Utility Pole No. NM 17/VZ 15 Along Henning Rd., Saratoga Springs, New York 12866 P'- J. P ICA�TION FOR D E-i SIGN R►�VHE�W BOARD APPROVAL a Lno! STATEMENT OF IINTTENT Submitted bV: Verizon Wireless Kathy Pomponi o - Network Real Estate 175 Calkins Rd Rochester, New York 14623 (585) 321-5365 Tectonic Engineering & Surveying Consultants, P.C. Steven Matthews, P.E. 36 British American Blvd, Suite 101 Latham, New York 12110 (518) 783-1630 Airosmith Development Inc. Sara Colman, Site Acquisition Specialist 318 West Ave. Saratoga Springs, NY 12866 (518) 461-7114 Please Direct Correspondence T®o Young/ Sommer LLC David C. Brennan, Esq. 500 Federal Street, 5th Floor Troy NY,12180 (518) 438-9907 Dated: June 24, 2026 DESIGN REVIEW BOARD OF THE CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORK In the Matter of the Application of CELLCO PARTNERSHIP d/b/a Verizon Wireless Premises: Utility Pole No. NM 17/VZ 15 -Along Henning Rd Saratoga Springs, New York 12866 STATEMENT OF INTENT and APPLICATION FOR DESIGN REVIEW BOARD APPROVAL I. Purpose and Need CELLCO PARTNERSHIP d/b/a Verizon Wireless ("Verizon Wireless" or the "Applicant") proposes the collocation of an unmanned public utility/personal wireless service facility (a "communications facility") at the above location. More specifically, Verizon Wireless is proposing to add wireless telecommunications equipment to the proposed replacement utility pole. The Applicant proposes to install on a replacement utility pole: a single, cylindrical antenna (approximately 24" tall x 14.6" in diameter) mounted at the top of the pole at a tip height of 41.7± feet along with the installation of electric and telecommunications equipment on the utility pole at a minimum height of 8' above grade. All proposed equiprnient zvill be painted brown as noted on Sheet C-2B and consistent with prior DRB approvals for similar projects. The existing utility pole measures 33.2± feet in height, the proposed utility pole measures 38.5± feet. The property is located in the right of way along Henning Rd., City of Saratoga Springs, Saratoga County, New York (NM 17/ VZ 15) . [Zoning Site Plan Drawings of Tectonic Engineering Consultants, Geologists & Land Surveyors, D.P.0 at TAB 6]. Upon completion, the proposed facility will provide additional wireless network bandwidth and improved performance to the nearby roads and the surrounding neighborhood areas, as shown in the accompanying coverage maps. More specifically, the site is proposed improve coverage and network performance along the surrounding portion of Henning Rd. [Proposed Coverage Map at TAB 31. Verizon Wireless is considered a public utility for land use purposes under New York decisional law (Cellular Telephone Conipan y v, Rosenberg', 82 N.Y.2d 364 [1993]), and a provider of "personal wireless services" under the federal Telecommunications Act of 1996 (the "TCA"). Verizon Wireless' equipment will be in Operation twenty-four (24) hours a day, seven (7) days a week, three hundred sixty-five (365) days a year. 1 In Rosenberg, the State's highest Court determined that the ordinary variance standard is inapplicable and a cellular telephone company applying for relief need only show that (1) the relief is "required to render safe and adequate service," and (2) there are "compelling reasons, economic or otherwise," for needing the variance. Cellular Telephone Company v. Rosenberg, 82 N.Y.2d 364, 372 (1993). 1 Verizon Wireless is .applying for review by the Design Review Board,2 The proposed replacement pole is located in the Rural Residential (RR) Zoning District. The facility is not located in the Historic Review District or the Architectural Review District. The proposed communications facility is unmanned and will be visited for routine maintenance purposes approximately two times per year (only as needed). As such, the project will not have any impact on existing water and sewage services. In addition, neither pedestrian nor vehicular access to the premises will be impacted [see Zoning Drawings at TAB 6]. II. Compliance with City Requirements The proposed communications facility complies in all material respects with City requirements: 1. SEQRA: A Short Environmental Assessment Form is attached as TAB 2. 2. Minimum Visual Impact: As noted above, Verizon Wireless' proposed facility is designed to have a minimum possible visual effect on the surrounding community and neighborhood [TAB 4]. 3. Site Plan: The Applicant has provided a Zoning Site Plan that identifies the proposed improvements [TAB 6]. Based upon the foregoing, Verizon Wireless respectfully submits that approval is appropriate in this case. III. Conclusion The communications facility proposed is a public necessity under Rosenberg in that it is required to render adequate and safe service to this area of the City of Saratoga Springs. In an effort to supplement existing telecommunications services to this area of the City Verizon Wireless has identified an appropriate location for the deployment of a small cell facility. Verizon Wireless' existing macro cell sites in the area do not provide adequate coverage and capacity to this area of the City. The City of Saratoga Springs will be lacking adequate and safe capacity, and the failure to approve this application will eliminate the means to provide necessary capacity. This, combined with the federal mandate to expeditiously deploy advanced wireless services across the nation and Verizon Wireless' FCC licenses to provide such services in the City of Saratoga Springs, demonstrates that Verizon Wireless' facility is a public necessity. Without the construction of the communications facility proposed, the public would be deprived of an essential means of communication, which, in turn, would jeopardize the safety and welfare of the community and traveling public. The small cell facility will not be noticeable to the traveling public or nearby property owners. The communications system proposed has been sited to have the least practical adverse 2 For the reasons set forth herein, Verizon Wireless believes that its project complies in all material respects with the provisions of the City of Saratoga Springs Land Use Laws and, consistent with the application process established by the City for prior Small Cell applications, that no additional approvals or relief are required. To the extent that an additional approval or relief is required, Verizon Wireless submits these materials in support of such approval(s). 2 visual effect on the environment, and any resulting impact(s) may properly be considered as minimal in nature and scope. Attached to this Application and Statement of Intent are the following: 1) An Application for Architectural/Historic Review by the Design Review Board; 2) A Short Environmental Assessment Form; 3) Radio Frequency Coverage Plots: 4) Photosimulations of the proposed installation and SEQRA Visual EAF Addendum; 5) Radio Frequency -Site Compliance Report; and 6) Project Zoning Drawings. Kindly place this matter on the agenda for discussion at the next available meeting of the Design Review Board. In the meantime, if you should have any questions or require any additional information concerning this project, I can be reached at (518) 438-9907. Thank you for your consideration. Dated: June 24, 2026 Respectfully submitted, CELLCO PARTNERSHIP d/ b/ a Verizon Wireless « 1 David C. Brennan, Esq. Regional Local Counsel 3 -AY+lANDVVR1TTEli APPLIC ATIONS WILL NOT BE ACCEPTED-1r1;!%, 1FOR OFFICE USEI TY OF A RATO ASPRINGS � ;C AM A DESIGN REVIEW BOARD CITY HALL - 474 BROADWAY SARATOGA SPRINGS NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.sai-atoga-spi-ings.org APPLICATION FOR. - ARCHITECTURAL/ HISTORIC REVIEW (Application #) (Project Title) Staff Review APPLICANT(51"" OWNER If not Aee fAt—ITORNEY/AGENT Name Cellco Partnership d/b/a Verizon Wirele! National Grid David C. Brennan, Esq. Address 1275 John St., Suite 100 300 Erie Blvd W 500 Federal St, FI- 5 West Henrietta, NY 14586 Syracuse, NY 13202 Troy, NY 12180 Phone 518-714-9282 , j ......... .. F M ai I dbrennan@youngsommer.com Identify primary contact person: 0 Applicant 0 Owner 7---! Attorney/Agent ... An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: PROPERTY INFORM" A T[ON ® Owner 1@ Lessee 0 Under option to lease or purchase ROW along Henning Rd. Utility Pole NA Property Address/Location: No: N A: 11M7jVzt1-3 Tax Parcel #: ( for avample: 165.52 — 4 — 37) Date Acquired by Owner: RR Current Zoning District: Property use: 0 Residential M Non-residential/mixed-use Type of Review: El Architectural ® Historic 11 Extension/modification (of current approval) Summary description of proposed action: Collocation of an unmanned public ufflifty/personal wireless service facility on a replacement wooden utility pole Nvitll the antenna tip height of 41.7 +/- ft. Has a previous application been filed with the DRB for this property? IN No 0 Yes — date(s)? Revised 12/21025 5 "A complete' application consists of 1hard copy Loriginal) d I electronic copy of apKhcation & kLL oL-�u'l Sr, .r1C11,11r-''-a�r[,a-k as rrequired below: New Construction /.Additions M--- Color photographs showing site/exterior details of existing structures and adjacent properties E� A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 1 7"xl 1 " sheet. 0 Elevation drawings showing design of all sides of existing 84 proposed construction — label dimensions, colors, materials, lighting (fi,,&,ture Rt lamp type, wattage), etc. - include compass beafi-ing & scale; no larger than Tx,3' sheet — smaller permitted if legible 8 4> 10 Floor plans for proposed structure; on sheet no larger than 2x3' — smaller permitted if legible El Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) -1-1 Color photographs showing site/exterior details of existing structures and that illustrate affected features 0 Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller perrnitted if legible 0 Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Distric (Front setbacks: UR-1 "11\!ST-HTR=30';UR-4=25'-,UR-2,UR-3(",.INCUD-1=10') Installation, removal or change in material of drive- and wall(ways Installation or removal of architectural, sculptural or vegetative screening over 3' in height Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: 0 Color photographs showing site/exterior details of existing structures, and of adjacent properties 1.71 Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than TO' sheet — smaller preferred if legible ® Product literature, specifications and samples of proposed materials and colors Signage / Awnings 0 Color photographs showing site/exterior details of existing structures, and adjacent properties ® Plan showing location of proposed sign/awning structure on building/premises., no larger than I I "x 17" El Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware 0 Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location El Product literature, specifications and samples of proposed materials and colors 1671-3011TOWINSTAI 0 Color photographs showing site/exterior details of existing structures, and of adjacent proper -ties 13 Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing., and scale 0 Written description of reasons for demolition and, in addition: El For structures of "architectural/Historical significance", demonstrate "good cause" why structure cannot be preserved 13 For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a 44 contributing" structure in a National Register district (contact City staff' , provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 12/2025 .Request for extension of current approval 0 Identify date of original DRB approval: Current expiration date, - Org. App. No. L71- Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEOR Environmental AsSessinnent Form ffl.. Applicants proposing the following must complete "Part I" of the SECT Short Environmental Assessment Form (available here: http://%"w.dec.ii . ov/docs ermits q operations df/seafpijrtonc_._jQd0: Construction or expansion of a multi -family residential structure (4 units +) Construction or expansion (exceeding 4,000 sq, ft. gross floor area) of a principal or accessory non-residential structure Telecommunications facility, radio antennae, satellite dishes Demolition f �, kz; c I n f� i i r cm - Does any City officer, employee or family nnamber thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? ,7�- No -0 Yes - If yes, a statement disclosing the name, residence, nature, and ex^tent of this interest must be filed with this application, certification 1/we, the property owner(s), or purchaser(s)/Iessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Board. By the Signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated with this application for purposes of conducting any necessary, site inspections relating to this application. F C> Furthermore, I/we agree to meet all requirements Linder Article V11 for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date:6/24/26 (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature-.' Owner Signature: Date: Bate: Revised 12/2025 I I 0GI CITY OF ARATO A SPRINGS DESIGN Ri-n/lIEW BOARD City Hall. - 474 Broadway Saratoga Springs, New York 12-866 Tel: 518-587-3550 x2533 www.saratoga-springs.org INSTRUCTIONS A RC H I T E C T u R A L I H I S T U R �n "R,1E Vi L----- %�- �\ f" P F01 1CAT11 0 N ELIGIBILITY: An applicant to the Design Review Beard for Architectural Revietpj or Historic Review must be -11.he property ov�iner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRB will only consider properly completed applications that contain 1 o, cai nd� I chi itall version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTEMI, 3. ACTIONs REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit . .......... . . . ................ 1--­1-- ....... ­-.1- . ....... . ...... Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure - any material change to exterior of a structure including: c, demolition of a st=ructure addition or removal of exterior architectural features installation, removal or material changes to exterior Within a non-residential zoning district: building elements Such as roof, siding, windows, doors, • a change in exterior building color porches, etc. • installation of an awning enclosure or screening or buildings openings such as windows, doors, porches, etc. installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: installation, removal or material changes to drive- or walkways installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height o installation of accessory utility structures or radio/satellite- transmission/reception devices over 2' in diameter a change in exterior building color within a non- residential zoning district a new, or change to an existing, sign or awning installation of telecommunications facilities Note — Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review, Revised 12/2025 k. DESIGN GUIDELINES: The Design Review Board will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height — consistent with historic form and context of site and surrounding properties • Scale — relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front facade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other faqade elements • Directional Expression — compatibility with horizontal & vertical expression of surrounding structures • Massing & Open Space — relationship of structure to open space between it and adjoining buildings o, kntbalck- — cornpatibility with surrounding strUMTe.S c Compatibility of the follmlvino- with surrounding structures/properties: Major building elements (store'ronts, doors, windows, roof - Building materials - Color — (in non-residential zoning districts only) i. I L PECISIONS: The Design Review Board may approve, approve with conditions, or disapprove an application. .4 The F,--' ; RC ,' may -impose appropriate conditions and safeeuards in connection with its approval including nature/ t..a quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Ne I 'r, has Sufficiently Application approvals shall e.."Pire x.A.11-1-hin H9 months of the filing date unless the project commenced (i.a. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga--sprin s.oFg) for rneeting dates. Applicatimis are placed on an agenda on first -come, first -served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "'Commissioner of Finance" REFER TO THE CURRENT FEE WORKS HEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Board responsibilities may be found in the City's Unified Development Ordinance available in City Hall and on the Cites -Areb site at https-./Iny-saratogaspri.n.gs.civiCPILLS.com/DocumentCenter/ View/17803/Full -UDO Revised 12/2025 City of Saratoga Springs OFFICE OF ?L4*1fflNG AIXID E-CONOMIC DEVELO?NlEi°!T FEES - 2026 Applicadon to City Council FEE .... ....... ......... . . . Comprehensive Plan Amendment ....... . . . .... ... . ..... . . ....... ..... ............... ..... $1,800 + $300/acre Zoning Ordinance Amendment $800 + $300/acre Planned Unit Development (PUD) Amendment - -- - ------ - ------------ $800 + $3001acre ........ Application to Zoning Board of Appeals F E_ E ...... . .. ... . . . Use GG Variance Area Variance Residential (1 & 2 Family) S1,400 + $75/,app $35011 st var + S75/app + $1 50/ea add variance Area Variance - 3+ Family and Commercial $1,000/1st var + $75/app, + $2001ea add variance Interpretations $650 + $75/app Post Work Application Fee Application Fee x2 + $705/app Variance Extensions 50% of Application Fee + $75/app __­..,__­­ ......... ....... . ...... I.- ....... ...... ..... ..... .. ... ............ . .............. . .. . .................... . . . . . .. . .. Application to Design Revlevv Board �7_ EEE ...... .... Demolition $500 Residential Structures — 1 or 2 Family, Principal or Accessory Structure. Materials Change - roof, windows, siding $75 Fagade Change - removal/addition of windows., doors, porch $ 150 Addition or new construction $300 Approval Extension 50% of Application Fee 3+8%,lulti-Family, Cor irD_JAixed-qse Principal or &qessory Structure Equipment Install or Materials Change - roof, windows, siding, paint color $150 Signs, awnings 11�0 150 ' Facade Change - removal/addition of windows, doors, porch $300 Addition or new construction $650 ApprOV21 Extension or Modification 50% of Application Fee Post Work Application Fee Application Y,2 Application to Planning Board Special Use Pen -nil $1,200 + S75/app Temporary Use Pert -nit $500 Special Use Permit - Extension $400 Special Use Permit - Modification $550 + $75/app Site Plan Review - incl. PUD Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non -Residential I Mixed -use $800 + $150/1,000 sf (Non -Res) + 250 unit (Res) Administrative SPR Residential $400 Non -Residential / Mixed -use $800 Extension Residential $250 Non -Residential / Mixed -use $350 Subdivision - incl. PUD Sketch Plan $400 Per sketch Preliminary Approval Residential: 1-5 Lots $700 + $75/app Residential: 6-10 Lots $1..100 + $75/app Residential: 11-20 Lots $1,450 + S751app Residential, 21+ Lots $1,800 + $75/app Residential - Extension $350 Final Approval Residential $1,550 + $200/lot + $75/app Non -Residential $2,400/lot + $75/app Final Approval Modification Residential $400 + $75/app Non -Residential $800 + S75/app Final Approval Extension Residential $250 Non -Residential $350 Subdivisions and Site Plans are subject to Engineering Review- See DPW Fees Other Lot Line Adjustment/Subdivision Administrative Action Letter of Credit — !Modification Extension Letter of Credit - Collection Recreation Fee Land Disturbance Activity Permit WatercourselWetland Pemiit WatercourseMetland Permit Entension SEORA EIS Review (Draft & Final) Sidemik Fee Lieu Tree Removal $400 $400 LIP to 1 % of LoC $2,OO011ot or unit $750 + $35/acre $750 $350 TSD See, DPW Fps Avg, nursery cost in caliper of new species equivalent to diameter at breat height (DBH of tree(s) Removod �� L` r'! �'/� ?/� // (1 � ;1 ��!II t:��/J`•/� 1 f, /1rr��1 ��' rrfJ,��-i7 I ) r?� ��\ (77YYr'n /✓�' n/ �� lr! T / �`J�, l/l/' L✓ L L L f_`�✓ r L Imo✓ )..✓ I.i� lY J L/ I `/� ( �' ����� 1 Part I - jF�roll�'�'�`� lrn?�C�J��1fLApr! 1 i 5f�t-uk�_c tf' � si 3 D�oir Co ie_ta _-- - P - rt 1 — Project lnforniation. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information, Complete all items in Part 1. You rnay also provide any additional information you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Name of Action or Project: Cellco P-lartnership, d/b/a Verizon Wireless - Unmanned wireless Facility - "Rood & Riddle" Project Location (describe, and attach a location neap): Right-of-way of Denning Rd, City of Saratoga Springs, Saratoga County, NY 12866 Brief Description of Proposed Action: Cellco Partnership d/b/a Verizon wireless ("Verizon Wireless" or "Applicant14) is proposing an unmanned wireless communications facility on a proposed replacement wood utility pole on Henning Rd. The subject pole is located on the Southeast side of the right-of-way of Denning Rd, approximately 0.66 miles south of Lake Ave. In general, the installation consists of the following: one (1) antenna mounted at a centerline height of 40.7' above grade on a proposed 35.5' (41.7' including antenna height) tall replacement wood pole. All accessory equipment, cabling and utility services (power and fiber) are proposed to be mounted to the good pole. Name of Applicant or Sponsor: Telephone: 585 321.5 435 I l'-'-�Vlai.l: kathy.pomponio@verizonwireiess.com Cellco Partnership d/b/a Verizon wireless; attn: lathy Pomponio Address: 175 Calkins Load City/PC): State: Lip Code: Rochester NY 14623 1. Does the proposed action only involve the legislative adoption of a plan, local law. ordinance, NO YES administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that may be affected in the municipality and proceed to Part 2. if No, continue to question 2. 2. Does the proposed action require a permit, approval or funding from any other government Agency? NO YES If Yes, list agency(s) name and perrnit or approval: City of Saratoga Springs - Design Review Board approval; Building permit -- 3. a. Total acreage of the site of the proposed action? <0.0001 acres b. Total acreage to be physically disturbed? <o.00n, acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor. <0.0001 acres 4. Check all land uses that occur on, are adjoining or near the proposed action: M Urban. Pn� Rural (non -agriculture) ❑ Industrial Commercial M Residential (suburban) E01 Forest Agriculture 0 Aquatic Q Other(Specifyy): Saratoga Race Track, 1-87 0 Parl(land Corridor Page 1 of 3 SEAF 2026 5. Is the proposed action., � .�._._..__._..�...�..m..�.�_ a. A permitted use under the zoning regulations'? b. Consistent with the adopted comprehensive plan'? NO YES NIA � 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? NO YES 7. .Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? If Yes, identify: NO YES 8. a. Will the proposed action result in a substantial increase in traffic above present levels? b. Are public transportation services available at or near the site of the proposed action? c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed action? NO YES - - ✓ 9. Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: NO YES I Q. Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable water: Proposed action does not require a potable water supply. NO YES ✓ 11, Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: Proposed action does not require wastewater treatment. NO YES 12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district which is listed oil the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? The project is substantially contiguous to the Union Avenue Historic District. b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory? NO YES ✓ 13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody`? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: Federal Wetlands adjoin the project site. The project does not propose any wetland disturbance. NO YES ✓ Page 2 of 3 SEAF 2026 1.4. Identify the typical habitat types that occur on, or are .Likely to be round on the project site. Check all that apply: ❑ Shoreline [* Forest [❑ Agricultural/grasslands ❑ Early Enid -successional ❑ wetland ❑ 'Urban FMI Suburban 1.5.Does the site of the proposed action contain any species of anirnal, or associated .habitats, listed by the State or I� ederal government as threatened or endangered`? NO YES RI El 16. Is the project site located in the 100-year or 500-year flood plain? NO YES 17. will the, proposed action create storm water discharge, either from point or non -point sources? If Yes, a. will stor n water discharges flow to adjacent properties? b. will storm water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: NO YES E]_ 1:1 18. Does the proposed action include construction or other activities that Would result in the impoundment of Water or other liquids (e.g., retention pond, waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment: r� NO YES 19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste management facility? If Yes, describe: NO YES 21 20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or completed) for hazardous waste? If Yes, describe: NO YES 21. Is the project located within, or within '/z mile of, a disadvantaged community? If No, could impacts from the project affect a disadvantaged community? If Yes to either question in. 21, answer the following question. a. Identify the potential pollution impacts of the project, either direct or indirect, that may occur within the disadvantaged community (e.g., wastewater discharges, air emissions, noise, odors, solid or hazardous waste generation or management): NO YES � 1 CERTIFY THAT T'HE INFORMATION PROVIDED ABOVE I'S TRUE AND ACCURATE rro THE BEST OF MY KNOWLEDGE Applicant/sponsor/name: Steven Matthews, agent on behalf of applicant Date: 6/15/2026 Signature: M-a-, Title: Director of Engineering Page 3 of 3 SEAF 2026 1­�'�.1;1C�;;[f��ir�.1.1 Monday, June 15, 2026 9:15 AM J n5a Foil, Rapor. Disclaimer The EAF Mapper is a screening tool intended to assist project sponsors and reviewing agencies in preparing an environmental assessment form (EAF). Not all questions asked in the EAF are answered by the EAF Mapper. Additional information on any EAF question can be obtained by consulting the EAF Workbooks. Although the EAF Mapper provides the most up-to-date digital data available to DEC, you may also need to contact local or other data sources to confirm data provided by the Mapper or to obtain data not provided by the Mapper. SLU'd K I U1 C, 1) 11) e n u b t6 H,)ni ill.an Dn BLIf fak) :A I h , USGS. S Err, HERE, G:wil-r&) E;i H �I:11)0 K, %r, 'i K i ES-1 7. 9L , E5 i . i,. I I E P, El. l' PIS Whn hi I I oh Part 1 / Question 7 [Critical Environmental No Area] Part 1 / Question 12a [National or State Yes Register of Historic Places or State Eligible Sites] . . ......... . Part 1 Question 12b [Archeological Sites] No Part 1 Question 13a [Wetlands or Other Yes - Digital mapping information on local, Ne\ivi York State, and federal Regulated Waterbodies] wetlands and waterbodies is known to be incomplete. Refer to the EAF Workbook. Part 1 Question 15 [Threatened or No Endangered Animal] Part 1 Question 16 [100 or 500 Year Digital mapping data are not available or are incomplete. Refer to EAF Floodplain] Workbook. Part 1 Question 20 [Remediation Site] No Part 1 Question 21 [Disadvantaged No Community] Short Environmental Assessment Form - EAF Mapper Summary Report I IA E ■ d) to 4) E > 00 &Z LO Q CL u 0- N CL O N M� ;r 4LA kid 'Lbd& OIIILI�O'lk AAW dr Pl .01 4% AA 6L y ti• r' X 1l� ... , 46 ftL .� t„ • - lop b IWO _ • .. _ 1 . •r., ., :fir•' _ ! • .�• .1 is _ r it :�s Wit•• r• i*i• • S�a't. lip .:,` � � #fir }f• , � ti +�,• r �"' �' •1 , O N a- J J16 so, t 41 ilk• . w 7p 4FV :1 14'il 4000�� 1 le 1, • Ile 14 1%V I I no-44 tow, r 46 tIr♦. T �•w' I a Y � , J%wA-3 r IF 16-4,e 4 • . r• I k-M c all, �— a: en 17.26 Appendix B State Environmental Quality Review VISUAL EAF ADDENDUM This form may be used to provide additional information relating to Question 11 of Part 2 of the Full EAF. (To be completed by Lead Agency) Distance Between Visibility Proj'ec� cand L�(F�-.,'esacujrce (in Miles) 1 Would the project be visible from: to - 1'/4 V4 - '/2 ii,�-2- 3 3- 5 5+ A parcel of land which is dedicated to and available to the public for the use, enjoyment and appreciation of natural or man-made scenic qualities? An overlook or parcel of land dedicated to public E El 0. E observation, enjoyment and appreciation of natural or man-made scenic qualities? A site or structure listed on the National or State El 0 Registers of Historic Places? State Parks? E J I The State Forest Preserve? I National Wildlife Refuges and State Game Refuges? 0 El 1:1 I National Natural Landmarks and other outstanding 0 F1 El 1:1 natural features? I National Park Service lands? El 1:1 I Rivers designated as National or State Wild, Scenic or Recreational? I Any transportation corridor of high exposure, such L F-7 L_J Li as part of the Interstate System, or Amtrak? A governmentally established or designated interstate 11 El 07 D El or inter -county foot trail, or one formally proposed for establishment or designation? A site, area, lake, reservoir or highway designated as scenic? Municipal park, or designated open space? El El 0 County road? 0 —1 0 F '1 1 State road? F] Local road? Henning Rd, Morrisey Ln 0 2. Is the visibility of the project seasonal? (i.e., screened by summer foliage, but visible during other seasons) E]Yes ZNo 3. Are any of the resources checked in question I used by the public during the time of year during which the project will be visible? Fv_�Yes No f ll'trGuQ� CIF 00STING 111 UAh1- --NViR JP lW PVT From each item checked in question 1, check those which generally describe the surrounding environment. ;Y V ! i � ` l� n 110' Essentially undevelopedEl; i Forested Agricultural i Suburban Residential Industrial � Commerical �- Urban River, Lake, Pond Cliffs, Overlooks Designated O S en Space 9 p p i Flat 0 Hilly D Mountainous Other NOTE: add attachments as needed 5. Are there visually similar projects within: 1 �% mile Yes No I mile yes No 2 miles Yes 1110 3 miles Yes 01 1110 i *Distance from project site is provided for assistance, Substitute other distances as appropriate. 6. The annual number of viewers likely to observe the proposed project is ,V0 1--ff when user data is unavailable or unknown, use best estimate. 2 Million ? C0NTE X T 7. The situation or activity in which the viewers are engaged while viewing the proposed action is: FREQUENCY H- olidays/ Aothdt1f Daily weekly Weekends Seasonally Travel to and from work Q o 0 0 Involved in recreational activities Q p 0 0 Routine travel by residents C ® 0 0 At a residence 0 0 0 At worksite O O O Other 0 p O Q Reset circet USA Verizon Wireless Site Compliance Report Site name - ROOD & RIDDLE Site Name: ROOD & RIDDLE Site Address: Along Henning Road, City of Saratoga Springs, NY, 12866 Structure Type: Utility Pole Report Information Report Date: May 22, 2026 Report Generated by: Mamta Venna Customer Contact: Rick Andras Compliance Statement Verizon Compliance Statement: Verizon Wireless is compliant with FCC rules and regulations in all publicly accessible areas. of: NEW �PG�PRLES Co �� T 02 o 7k' � as 70 n Z m��t�` �86835 OAROFESS1��P� David C. Cotton, Jr. Licensed Professional Engin er State of New York, 086838 Date: 2026-May-29 Warning: It is a violation of New York State Law, Article 145, Section §7209 for any person, unless acting under the direction of a licensed professional engineer, to alter this document in any way. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA * 19422 cirmcet USA Contents 1. Executive Summary........................................................................................................................................................3 2. Antenna Inventory .........................................................................................................................................................4 3. Analysis...........................................................................................................................................................................5 4. Appendix A: Reference Information............................................................................................................................... 6 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell o PA * 19422 circet USA 1. Executive Summary Verizon Wireless has contracted with Circet USA, an independent Radio Frequency consulting firm, to determine if the proposed telecommunications facility is in compliance with Federal Coirununications Commission (FCC) rules and regulations regarding RF exposure as defined in 47 CFR § 1.1307(b) and 1.1310. This document and the conclusions herein are based on the information provided by representatives of Verizon Wireless which is assumed to be true and correct. All information used in this report was analyzed to determine compliance in publicly accessible areas, in particular at ground level. The analysis evaluates the telecommunications facility with respect to the General Population/Uncontro I led Maximum Permissible Exposure (MPE) limits. Circet USA has taken into consideration the Verizon Wireless antenna system as well as any existing antenna systems at the subject location. Verizon Wireless final antenna count is (1) antenna. Based on the analysis, Circet USA has determined that: Verizon Wireless is compliant in all publicly accessible areas with the FCC rules and regulations governing human exposure to RF electromagnetic fields as described in 47 CFR § 1.1307(b) and 1.1310. With the proposed Verizon Wireless antenna configuration in service, the composite exposure from this facility in all areas at ground level will be less than 1 % of the General Population MPE limit, or over 100 times less than the maximum allowed exposure in publicly accessible areas. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell * PA 9 19422 cirmcet USA 2. Antenna Inventory The table below contains data provided by Verizon Wireless representatives and/or gathered by Circet USA personnel. This data was used to perform the RF exposure analysis. Ant ID Owner Antenna manufacturer Antenna model (o) Mech. Tilt Azimuth (°) Height (ft) Frequency band Elec. c. Tilt HBW (�) VBW (°) Total power (Watts) Gain (dBd) ERP (Watts) 1 Verizon XvVN Wireless CX160r,.11236-BF22 0 0 ! 40.7 LTE 1900 2 360 27.1 I 63.5 5.25 213 1 Verizon SSA Wireless CX160MI236-BF22 0 0 I 40.7 AWS3 LTE 2100 2 360 27.1 190.6 5.25 639 1 Verizon JrvttA, Wireless CX160N11236-BF22 0 0 40.7 NR 3.7GHz 2 360 9.4 142.9 7.65 832.05 Notes: Each row with the some number in the Antenna ID column references the some physical antenna. Power values provided by the client and used in the analysis may be greater than what is initially deployed. 80% TDD Duty Cycle and 100% FDD Duty Cycle are used. Jumper/connector/coax loss between RRHs and antenna AWS/PCS: 2 dB C-Band: 2.5 dB 1777 Sentry Parkway W. Building 11 a Suite 201 Blue Bell e PA • 19422 circet USA 3. Analysis Circet USA has included the Verizon Wireless antenna system at the subject location in the analysis. All existing and proposed antennas are listed in the antenna table above. Engineering assumptions were used when. specific antenna or operating parameter information was not available for the other existing collocated antennas (if applicable). Using this data, software modeling using IXUS software was performed for all transmitting antennas located at the site. Circet USA has assumed a 100% duty cycle and maximum radiated power. The site has been modeled with these assumptions to determine the maximum potential RF energy density at ground level. Circet USA believes this to be a worst -case analysis based on the best available data. As stated previously, based on this analysis, the calculated ground level exposure from the Verizon Wireless antenna system alone is less than 1 % of the General Population MPE limit. Keep in mind that the FCC did not arbitrarily establish their own standards but rather adopted the recommendations of national and international organizations such as the National Council on Radiation Protection and Measurements (NCRP), the American National Standards Institute (ANSI) and the Institute of Electrical and Electronics Engineers (IEEE). These recommendations were developed by expert scientists and engineers following extensive evaluation of the potential biological effects from RF exposure. The FCC MPE limits are based on thresholds for known adverse effects, and they were designed to provide a substantial margin of safety. There is a safety factor of 50 built into the General Public MPE limits, and the predicted Verizon Wireless exposure levels are over 100 times below these very conservative limits. In cases where such compliance exists, the subject of electromagnetic field safety is preempted by the Telecommunications Act of 1996, which states: "No state or local government or instrumentality thereof may regulate the placement, construction, and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply with the (Federal Communication) Commission's regulations concerning such emissions." The graph below provides a visual depiction of the rather insignificant electromagnetic field exposure contribution from the Verizon Wireless antenna system out to a distance of 500' from the base of the structure. This portrays how low the Verizon Wireless contribution is when compared to the General Population MPE limit. ?/6 General Public MPE vs Distance 120 100 LU 80 a 1-i 60 v a 40 20 0 0 50 100 150 200 250 300 350 400 450 500 Distance (ft) -VZW MPE Contribution -FCC MPE limit 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell 9 PA • 19422 crcet USA 4. Appendix A: Reference Information FCC Rules & Regulations All information used in this report was analyzed as a percentage of the MPE limits as detailed in 47 CFR S 1.131 0. The calculated power density at each sample point divided by the limit at each calculated frequency provides a result in % MPE. Summing the calculated % MPE from all contributors provides accumulative 01/0 MPE at a particular sample point. Wireless carriers use different frequency bands with varying MPE limits; therefore, it is useful to report results in terms of % MPE as opposed to power density. All results were compared to the FCC radio frequency exposure rules as detailed in 47 CFR § 1.1307(b) to determine compliance with the MPE limits for General Population/Uncontrolled environments as defined below: 1 wo Uli NSHICHtlulls lur Exposure LIMIts Occupational — Applies to situations in which persons are "exposed as a consequence of their einploym-ent" and are "fully, alvare of the potential for exposure and can exercise control over their exposure". Environment Classification General Population — Applies to situations in which persons are "exposed as a consequence of their employment maynot be made fidly aii,,are of the potential for exposure or cannot exercise control over their exposure". Generally speaking, those without significant and documented RF Safety & Awareness training would be in the General Population classification. Controlled — Applies to environments that are restricted Uncontrolled — Applies to environments that are or "controlled" in order to prevent access from members unrestricted or "uncontrolled" that allow access from of the General Population classification. members of the General Population classification. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 circet USA FCC Limits for Maximum Permissible Exposure (MPE) Plane -wave Equivalent Power Density 1000 N 100 0 1 E 10 � 1 L 3 Q. 0.1 0.01 — Occupational —General Public '0000/ 0 1 10 100 1, 000 101000 Frequency (MHz) The MPE limits defined in 47 CFR § 1. 13 10 and utilized in this analysis are outlined in the table and diagram below: Vin t8 for Occu atlonallControlled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength Strength (S) E ', H , or S (MHz) (E) (N7/m) (H) (Alm) (MW/cm') (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f2)* 6 30-300 61.4 0.163 1.0 6 300-1500 -- -- f/300 6 1500-100,000 -- -- 5 6 Lim tS or General Po tllatlolllUncontrolled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Mange Strength Strength (S) JE 12, 1111112, or S (MIIz) (E) N'/m) (II) (A/m) (m�'�'/cm-) (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f2)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/1500 30 1500-1005000 -- -- 1.0 30 f = fr•equericy iii AM..: * = Plane -wave equivalent power densi 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA * 19422 FtfrcitY St 4 S17E Road b Ridzatcza Hospital I VA /4 w Yc'ddc lard 5 VICINITY MAP DIRECTIONS DIRECTIONS TO SITE: FROM NORTH GREENBUSH SWITCH FACILITY, TURN LEFT ONTO JORDAN RD. TURN LEFT ONTO US-4 N/N GREENBUSH RD. AT THE TRAFFIC CIRCLE, TAKE THE 1ST EXIT ONTO US-4 N. TURN LEFT ONTO MORRISON AVE. TURN LEFT ONTO NY-378 W/HIGH ST. USE THE RIGHT LANE TO MERGE ONTO 1-787 N VIA THE RAMP TO COHOES. MERGE ONTO I-787 N. USE THE RIGHT LANE TO MERGE ONTO NY-7 W VIA THE RAMP TO I-87/SCHENECTADY/SARATOGA SPRINGS. TAKE THE EXIT ONTO 1-87 TOWARD SARATOGA SPGS/GLENS FLS. TAKE EXIT 14 FOR NY-9P TOWARD NY-29/SARATOGA SPRINGS/SCHUYLERVILLE. USE THE RIGHT LANE TO TAKE THE RAMP ONTO NY-9P N/UNION AVE. USE THE RIGHT LANE TO MERGE ONTO NY-9P N/UNION AVE. TURN RIGHT ONTO HENNING RD. THE SITE WILL BE ON THE RIGHT. CELLCO PARTNERSHIP, d/b/a ■ ��erizon ROOD RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 UTILITY POLE #: NIVI 17/VZ 15 SITE ADDRESS: ALONG HENNING RD SARATOGA SPRINGS, NY 12866 MUNICIPALITY: CITY OF SARATOGA SPRINGS COUNTY: SARATOGA TAX MAP NUMBER: PUBLIC R.O.W. STRUCTURE COORDINATES: 43.074339' —73.754579' GROUND ELEVATION: 262'± AMSL POLE OWNER: NATIONAL GRID/VERIZON POLE #: NM 17/VZ 15 APPLICANT: VERIZON WIRELESS 1275 JOHN STREET, SUITE 100 WEST HENRIETTA, NY 14586 CONTACT PERSON: KATHY POMPONIO CONTACT PHONE: (585) 321-5435 PROJECT SUMMARY PROJECT DESCRIPTION THE PROPOSED WORK CONSISTS OF: • REMOVE EXISTING WOODEN UTILITY POLE. REPLACE WITH A PROPOSED 45' (CLASS 1) 'WOODEN UTILITY POLE AND RELOCATE ALL APPURTENANCES TO THE PROPOSED POLE. • INSTALL (1) CELLULAR ANTENNA & ASSOCIATED EQUIPMENT ON PROPOSED POLE. • INSTALL ELECTRICAL, TELCO AND CABLE ROUTING .AS NECESSARY. SHT. NO. DESCRIPTION REV NO REVISION DATE T-1 TITLE SHEET 1 06/09/26 GN-1 GENERAL NOTES 1 06/09/26 C-1 SITE PLAN & EQUIPMENT PLAN 1 06/09/26 C-2A MAKE READY SCOPE OF WORK 1 06/09/26 C-2B POLE ELEVATION & DETAIL 1 06/09/26 C-3 POLE MOUNT DETAILS 1 06/09/26 E-1 ELECTRICAL & GROUNDING DIAGRAMS & DETAILS 1 06/09/26 SHEET INDEX THIS SET OF PLANS SHALL NOT BE UTILIZED AS CONSTRUCTION DOCUMENTS UNTIL ALL ITEMS OF CONCERN HAVE BEEN ADDRESSED AND EACH OF THE DRAWINGS HAS BEEN REVISED AND ISSUED "FOR CONSTRUCTION". SUMMARY OF MAKE READY WORK I. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS, 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450) 3. REPLACE SPAN OF NEUTRAL TO P18 WITH 250' OF 1 /0 TPX. 4, ATTACH TPX AT 31'6". 5. REPLACE SEC BRACKETS (NG 10-101 FIG 5). 6. REPLACE PRI DG (NG 3-105). 7. INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. LICENSE APPLICATION #ROOD & RIDDLE/MDG:5000993724 WORK REQUEST #30352102 UTILITY PROVIDERS ELECTRIC PROVIDER: NATIONAL GRID ESR #: 31326318 ACCOUNT #: 47801-80005 FEEDER#: XXXXX PLANNER: TBD PHONE: (XXX) XXX—XXXX FIBER: VER€ZON Before You Dig, Drill Or Blast! Dig � Safely. New York UNDERGROUND FACILITIES PROTECTIVE ORGANIZATION CALL US TOLL FREE 1-800-962-7962 NY ind:uYial code rule 7,53 requires no less thar, two working days r:ot:e, but not more than ten cay3 notice. DIG SAFELY - N EW YORK DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED FOR 22'*x34" FULL SIZE AND 11"x17" HALF SIZE. OTHER SIZED VERSIONS ARE NOT PRINTED TO THE SCALE SHOWN. CONTRACTOR SHALL VERIFY ALL PLANS, EX"STING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. verizon 175 CALKINS ROAD I ROCHESTER, NY 14623 Tectoni *c ..ACTI� SOLB'f1CML EXCRI,ON" 31111MCIL Teetonle EnOww" Cmm&wrte, Waloglele 4 land &eveyore, Q.P C. Pevj.ct Confaer Info 38 Br;tleh Amerlcan Blvo. Phone: (518) 783-16M Suite 101 (800) 829-6531 Latham. NY 12110 w�w.tectcnicengineering.com NO NUMBER DRAWN BY REVIEWED BY 12861.115 LP1F MP Alf% r%ATC' lecl1: 0 05/06/26 FOR REGULATORY 1 06/09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR 15 A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES (11 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 TITLE SHEET SHEET NUMBER T�l ELECTRI CAL NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE LOCAL CODES. 2. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED. 3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 4. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 5. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 6. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA. 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S). 8. PANELBQARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED. 9. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, STRANDED COPPER CABLE RATED FOR 90"C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (#6 AWG OR LARGER), 600 V. OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, STRANDED COPPER CABLE RATED FOR 90'C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE USE-2 CABLE (##14 AWG OR LARGER), 600 V, OIL RESISTANT RHW-2 OR XHHW-2, STRANDED COPPER CABLE RATED FOR 90-C (WET AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED. 12. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND W fRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 90'C. 13. ELECTRICAL METALLIC TUBING (EMT) OR RIGID METALLIC CONDUIT (RMC) SHALL BE USED FOR EXPOSED OR CONCEALED LOCATIONS. 14. ALL OUTDOOR EXPOSED CONDUIT SHALL BE PVC SCHEDULE 80 AND SHALL BE SUPPORTED ADEQUATELY. 15. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. LFMC SHALL CONFORM TO NEC ARTICLE 350. 16. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 17. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE NTH NEMA, UL, ANSI/IEEE. AND NEC. 18. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 3R (OR BETTER) OUTDOORS. 19. IF REQUIRED, CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS, SERVICE ROUTING, AND METER SOCKET TYPE WITH LOCAL POWER COMPANY. 20. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS. 21. CONTRACTOR SHALL LABEL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.16 AND 110.24. 22. CONTRACTOR SHALL VERIFY THAT THE MAIN BONDING JUMPER AND GROUNDING ELECTRODE CONDUCTOR IS INSTALLED PROPERLY AT SERVICE ENTRANCE. 23. WHERE ELECTRICAL POWER IS TO BE SUB -FED FROM AN EXISTING DISTRIBUTION SYSTEM, THE FOLLOWING SHALL APPLY: A. CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND PER N.E.C. ARTICLE 220. B. CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE 220. C. EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS EQUIPMENT SUPPLYING IT. D. PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE LOCATED IN EXISTING PANEL. ANTENNA MOUNTING NOTES 1. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO ANSI /TIA-222-H-2017 "STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES, ANTENNAS AND SMALL WIND TURBINE SUPPORT STRUCTURES". THE BUILDING CODE OF NEW YORK STATE, AND ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL CODES. 2. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC (HOT -DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS OTHERWISE NOTED. 3. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC -COATING (HOT -DIP) ON IRON AND STEEL HARDWARE", UNLESS OTHERWISE NOTED. 4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780 "REPAIR OF DAMAGED AND UNCOATED AREAS OF HOT -DIP GALVANIZED COATINGS", USING COLD GALVANIZING COMPOUND AS MANUFACTURED BY ZINGA-USA OR ZINC KOTE, OR ENGINEER APPROVED EQUAL WITH A MINIMUM METALLIC ZINC CONTENT OF 95% BY WEIGHT 1N DRY FILM. DRY FINISHED COATING THICKNESS SHALL BE 3 MILS MINIMUM. 5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE NUTS AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 6. DESIGN OF THE ANTENNA MOUNTING BRACKETS, SUPPORTS, AND ALL COMPONENTS THEREOF AND ATTACHMENT THERETO SHALL BE THE RESPONSIBILITY OF THE MANUFACTURER. MANUFACTURER SHALL PROVIDE THE OWNER DRAWINGS DETAILING ALL COMPONENTS OF THE ASSEMBLY, INCLUDING CONNECTIONS, DESIGN LOADS, AND ALL OTHER PERTINENT DATA. MANUFACTURER SHALL ALSO PROVIDE THE OWNER WITH A STATEMENT OF COMPLIANCE, INDICATING THAT THE ANTENNA SUPPORTS HAVE BEEN DESIGNED IN ACCORDANCE WITH ANSI/TIA-222-H STANDARDS. ALL SUBMISSIONS SHALL BEAR THE SIGNATURE AND SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK. STRUCTURAL NOTE 1. THE VERIFICATION OF STRUCTURAL ADEQUACY AND DESIGN OF THE ATTACHMENTS MUST BE PERFORMED, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK. 2. REFER TO STRUCTURAL ANALYSIS REPORT PREPARED BY XXXXXXXXXXX DATED XX/XX/XX. GROUNDING NOTES GROUND TESTING AFTER CONSTRUCTION: 1. AFTER COMPLETION OF CONSTRUCTION OF THE CELL SITE GROUND SYSTEM, A POST INSTALLATION GROUND TEST SHALL BE PERFORMED BY THE CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE GROUND RESISTANCE FOR ALL SITES AFTER INSTALLATION OF THE EARTH GROUND SYSTEM. A PRELIMINARY EARTH RESISTIVITY TEST (3 POLE TEST OR CLAMP -ON -METER) SHALL BE PERFORMED PRIOR TO BACK FILLING ALL TRENCHES AS SPECIFIED IN VERIZON NETWORK STANDARDS (NSTD46) AND THE NATIONAL ELECTRIC CODE. 2. APPROVED MEASUREMENT METHODS FOR POST INSTALLATION GROUND TESTING SHALL BE ONE OF THE FOLLOWING METHODS: A. FALL OF POTENTIAL METHOD - 3 POINT B. CLAMP -ON RESISTANCE TEST C. TOWER AND EXTERNAL CONDUCTOR TEST 3. A GROUNDING RESISTANCE TEST REPORT SHALL BE PREPARED UPON COMPLETION OF THE TESTING. THE TEST REPORT SHALL SHOW THE RESISTANCE IN OHMS AT 40%, 52%, 62%, 72% AND 82% POINTS IN 10% INTERVALS. RESISTANCE IS TO BE RECORDED AT EACH INTERVAL FOR EACH POINT FOR FOUR (4) DIFFERENT DIRECTIONS UNTIL THERE IS A PLATEAU SEEN AT THE 62% POINT. TESTING SHOULD BE COMPLETED IN A MINIMUM OF TWO (2) DIFFERENT DIRECTIONS AT 90 DEGREES .APART. RECORD THE AVERAGE OR MEAN AS THE RESISTANCE OF THE SITE AND ENTER THIS ON THE POST RESISTANCE DATA CHART. 4. PROVIDE THE POST INSTALLATION - GROUND RESISTANCE TEST REPORT TO THE REGIONAL PROJECT ENGINEER ACCOMPANIED BY THE POST RESISTANCE DATE CHART. 5. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. ALL BENDS SHALL BE MADE WTH 12" RADIUS OR LARGER. 6. APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 7. GROUNDING TEST SHALL BE TAKEN BEFORE A/C POWER, NEUTRAL/GROUND BOND IS CONNECTED. 8. ANTI -OXIDATION CONDUCTIVE COMPOUNDS ARE REQUIRED ON ALL GROUND CONNECTIONS. NO OX-ID (COSMOLINE GREASE BASED COMPOUND) SHALL BE USED FOR COPPER TO COPPER CONNECTIONS. ZINC BASED COMPOUND (GREY COLORED) OR APPROVED EQUAL SHALL BE USED FOR COPPER TO STEEL CONNECTIONS. 9. ALL LUG CONNECTIONS & THEIR MATING SURFACES SHALL BE CLEANED AND COATED WITH THE APPROPRIATE ANTI -OXIDIZING CONDUCTIVE COMPOUND. IF A LUG CONNECTION IS TO BE SECURED DIRECTLY TO A PAINTED SURFACE, THE PAINT SHALL BE REMOVED TO REVEAL BARE METAL AROUND THE AREA OF THE CONNECTION AND COATED WITH AN APPROPRIATE ANTI -OXIDATION CONDUCTIVE COMPOUNDS. GENERAL NOTES 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK STATE BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND ORDINANCES. 2. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND MAKE PROVISIONS AS TO THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE .ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 3. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS OTHERWISE NOTED. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 4. DIMENSIONS SHOWN ARE TO FINISH SURFACES, UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE CARRIER'S AUTHORIZED REPRESENTATIVE OR THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 5. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 6. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ALL PRODUCTS OR ITEMS NOTED AS "EXISTING" WHICH ARE NOT FOUND TO BE IN THE FIELD. 8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. 9. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, AND ADJACENT AREAS, THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS. 11. CONTRACTOR SHALL COORDINATE HIS WORK AND SCHEDULE HIS ACTIVITIES AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS OF THE OWNER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH THE WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS AND ANY OTHER PORTIONS OF THE WORK. 13. CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT THE OWNER AND CARRIER. 14. INSTALL .ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 15. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT, IMPROVEMENTS, PIPING, ANTENNA AND ANTENNA CABLES. REPAIR ANY DAMAGE THAT OCCURS DURING CONSTRUCTION. 16, REPAIR ALL EXISTING SURFACES DAMAGED DURING CONSTRUCTION SUCH THAT THEY MATCH AND BLEND WITH ADJACENT SURFACES. 17. KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 18. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND ERECTION OF ANY MATERIAL. ANY UNUSUAL CONDITIONS SHALL BE REPORTED TO THE ATTENTION OF THE ENGINEER. 19. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND INSPECTIONS AND PAY ALL REQUIRED FEES. 20. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A/10-BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDOUT AREA DURING CONSTRUCTION. 21. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS AND OTHER DOCUMENTATION SHALL BE TURNED OVER TO CARRIER AT COMPLETION OF CONSTRUCTION. 22. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF ACCEPTANCE BY CARRIER. ANY WORK, MATERIALS, OR EQUIPMENT FOUND TO BE DEFECTIVE DURING THAT PERIOD SHALL BE CORRECTED IMMEDIATELY UPON WRITTEN NOTIFICATION AT NO ADDITIONAL COST TO CARRIER. 23, RIGGING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH STATE AND FEDERAL SAFETY REGULATIONS (OSHA). ENGINEER, CARRIER AND THE OWNER SHALL BE HELD HARMLESS IN THE EVENT THE CONTRACTOR DOES NOT FOLLOW SUCH SAFETY REGULATIONS. 24. CONTRACTOR SHALL PROVIDE ACCESS TO THE SITE AND ASSIST THE RADIO EQUIPMENT VENDOR AND THE ANTENNA INSTALLATION CONTRACTOR AS THEY MAY REQUIRE. vverizon I 175 CALKINS ROAD I ROCHESTER, NY 14623 • 'Iwi Tectonic rRAMCA.soLmOIRL EXCEMowLLsuMOL Tww* & w" mmuft lht, "a "Ift i tmd &awywl, O.P.C. Project cantact Into 36 British Amerlcon Blvo. Phonr. (518) 783-1630 Suite 101 (800) 829-8531 Latham, NY 12110 www.tectomicengincefing.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 11 LPJF MP kin Harr, Icci Tr, 0 05/06/26 FOR REGULATORY 1 06/09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 i ORIGINAL SIZE IN INCHES (11x17 FORMAT) ROOD &RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 GENERAL NOTES SHEET NUMBER 13# NORTH ORIENTATION N 7l 1. NOR 4 H ORIENTATIO'J ESTABL ISId ..0 N BY COMPASS OBSERVATION!. EDGE OF EXISTING—., PAVEMENT ,IIF1 1`� < 'C' O 41 �. o y. ♦ , � F its r ! A t�w M C. Ir 1 EXISTING OVERHEAD , ► / ' WIRE (TYP) d .. . \ yf) # / t +� C' PROPOSED VERIZON WIRELESS EQUIPMENT ON PROPOSED UTILITY POLE. NEW POLE TO \ t REPLACE EXISTING UTILITY POLE #NM 17/VZ 15 \ 1 e r s ir; do ` �— EKSTI Nt U11LITY POLE `TIP) R NOTE: SITE IN- ORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING CONSULTANTS, GEOLOGISTS & LAND SURVEYORS D.P.C., OIJ 11 /10/25. 1 SITE PLAN 1" - 8"" (11x17 S12E) 1- = 40' (22x34 S17E) EXISTING UTILITY POLE TO BE REMOVED & REPLACED EQUIPMENT PLAN C-1 SCALE: 3/4' = 1•-0" (11x17 SIZE) 1 1/2" - (22x34 SIZE) PROPOSED VERIZON WIRELESS EQUIPMENT SHROUD WITH PROPOSED RRH AND ASSOCIATED EQUIPMENT (SEE DETAIL 5/C-3) PROPOSED FUJITSU PASSIVE - FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD PROPOSED VERIZON WIRELESS 1" FIBER CONDUIT PROPOSED 1-1/2" CONDUIT (FROM SECONDARY TO METER) PROPOSED UTILITY POLE 3 SHROUD PLAN VIEW ` SCALE; 3/4" = 1'-0" ('tx,7 SIZE) 1-1/2" = 1•-0" (22x34 SIZE) PROPOSED #2 VERTICAL GROUND 1-1 /2" (FROM RY TO METER) --PROPOSED METER PROPOSED #2 VERTICAL GROUND -PROPOSED 100A LOAD CENTER DPOSED 1-1 /4" RISER FOR AC C`I IITq Tn gHRni In -GUARD FOR ANTENNA verizon 175 CALKINS ROAD 11 ROCHESTER, NY 14623 Tectonic PRAC"i SOMC . Te,_tone E4%MWA0ComAwta, 090bolb ! Land %-wtom, "-.- Project ca":-tact Into 36 8r-tlwh Amerizon BlvC Phorn. '5'8) 7,43-1630 SJ;te 10' {900) 82.9-6531 Latnam, NY 12110 »wwAezt3mcengincerngxom NO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP kin 11A= ICCI IC 0 05/G6/26 FOR REGULATORY 1 05/D9/26 ADDED PAINT NOTE pF A` j UNAUTHORIZED AL =RATION CR ADDITIONS TO A PLAN: BLARING THE SEAL OF A LICENSED ENGINEER OR LAP:D SURVEYOR IS A VIOLATION OF SECTION 7209 SUED - VISION 2 OF THE NEW YORK STATE EDUCATION u.w. COPIES OF THIS DOCUMEN' VlrTHOUT A FACSIMILE 0= THE SIGriATLRE AND AN: ORIGINAL EMBOSSED SEAL OR OR;GINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR L-.'JD SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES- 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 ORIGINAL SIZE IN INCHES (11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE IDS: 17612418 MDG#: 5000993724 511E ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE SITE PLAN & EQUIPMENT PLAN SHEET NUMBER Cw�l SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE (NG 9-450) 3. REPLACE SPAN OF NEUTRAL TO P18 1MTH 250' OF 1/0 TPX. 4. ATTACH TPX AT 31'6". 5. REPLACE SEC BRACKETS (NG 10-101 FIG 5). 6. REPLACE PRI DG (NG 3-105). 7, INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. LICENSE APPLICATION BROOD & RIDDLE/MDG:5000993724 WORK REQUEST ##30352102 t� F 4 ...• I• ti , z • , 1 EXISTING POLE PHOTO C-2A SCALE: NTS EXISTING PRIMARY ELECTRIC 34.0'± AGL \ TOP OF EXISTING UTILITY POLE 33.2'± AGL EXISTING PRIMARY ELECTRIC _ 31.3'± AGL EXISTING DOWN GUY WIRE IX 30.0'± AGL EXISTING PRIMARY ELECTRIC LINE TO BE RELOCATED PER NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) EXISTING PRIMARY ELECTRIC CROSSARM TO BE REMOVED & REPLACED PER NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) R_ - EXISTING SECONDARY ELECTRIC LINE TO BE RELOCATED PER f NATIONAL GRID REQUIREMENTS EXISTING SECONDARY (SEE 3/C-2A) 26.3'± AGL EXISTING DOWN GUY TO BE REMOVED & REPLACED � -- EXISTING COMM LINE TO BE r1h EXISTING FIBER LINE � ✓% RELOCATED (BY OTHERS) 22.7 ± AGL EXISTING DOWN GUY WIRE EXISTING COMM LINE TO BE 22.7'± AGL RELOCATED (BY OTHERS) EXISTING COMM LINE 22.0'± AGL EXISTING UTILITY POLE #NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE STREET SIDE 2 EXISTING UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (22x34 SIZE) 19" TOP �OF PROPOSED UTILITY POLE REPLACE PRIMARY 38.5 ± AGL / CROSSARM WITH NG 9-450 RELOCATED PRIMARY 36.5'± AGL-� NEW/REPLACEMENT DOWN GUY WIRE 35.2'± AGL NEW REPLACEMENT SECONDARY 31.5'± AGL RELOCATED FIBER LINE MR-) 25.0'± AGL r rik RELOCATED DOWN GUY WIRE % 25.0'± AGL -0RELOCATED COMM LINE -24.0 ± AGL REPLACE PRI DG (NG 3-105). INSTALL SEC DG (NG 3-118) CONFIRMED ON EXISTING THIMBLE REPLACE SPAN OF NEUTRAL TO P18 WITH 250' OF 1/0 TPX. ATTACH TPX AT 31'6". REPLACE SEC BRACKETS (NG 10-101 FIG 5) COMM/FIBER REATTACHMENTS TO BE DONE BY OTHERS (BY OTHERS) EXISTING UTILITY POLE #NM 17 /VZ 15 TO BE REMOVED & REPLACED EXISTING GRADE i STREET SIDE 3 PROPOSED UTILITY POLE ELEVATION C-2A SCALE: 3/16" = 1'—O" (11x17 SIZE) 3/8" = 1'—O" (2204 SIZE) 'verizon 1 175 CALKINS ROAD ROCHESTER, NY 14623 la Tectonic FRACMAL sousnmca. Tat*m EmOw" Co mAmts, Codogisr i lad Uwwp s, Q.P.C. Proj. ? Gamut Info 36 British Amorleon Blva. Phor: (518) 783-1G3.9 Suiv te 101 800 829-6531 Latham. NY 12110 www.to&-onicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP MP Alf% r%ATC ICCIIC 0 05/06/26 FOR REGULATORY 1 06/09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES (11x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 MAKE READY SCOPE OF WORK C-2A NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. PROPOSED 4G ANTENNA (SEE DETAIL 1 /C-3) PROPOSED POLE TOP ANTENNA MOUNT (SEE DETAIL 1 /C-3) INSTALL RF "CAUTION" SIGNAGE 2't BELOW PROPOSED ANTENNA (SEE DETAIL 4/C-3) PROPOSED WEATHERHEAD FOR POWER (CARLON P/N: E99SH-CAR OR APPROVED EQUAL) PROPOSED COAX CABLES TO ANTENNAS IN 4" MAX U-GUARD PROPOSED MOPT TERMINAL - (BY OTHERS) PROPOSED LC/UPC BIDI RUGGEDIZED FIBER -� JUMPER FROM THE PROPOSED MOPT TERMINAL TO PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE WITHIN 1" CONDUIT PROPOSED VERIZON WIRELESS - EQUIPMENT SHROUD WITH PROPOSED RRH & ASSOCIATED EQUIPMENT (COMMSCOPE PN: SSC-760249586X1 X OR EQUAL) (SEE DETAIL 5/C-3) PROPOSED 1-1/4- PVC RISER FOR - AC CIRCUITS TO SHROUD PROPOSED EATON BRP12B10OR LOAD CENTER OR APPROVED EQUAL (SECURE TO POLE USING UNISTRUT OR APPROVED MANUFACTURER RECOMMENDED HARDWARE) PROPOSED RF "INFORMATION" -� SIGNAGE (SEE DETAIL 4/C-3) PROPOSED METER MILBANK P/N: U2048-RL OR-/ APPROVED EQUAL (SECURE TO POLE USING ERICKSON SERIES PBAL MOUNTING BRACKET OR ELECTRIC COMPANY APPROVED EQUAL) TOP OF PROPOSED ANTENNA 41.7'f AGL - - --- --q PROPOSED ANTENNA- ---- --- -- - - 40.7'f AGL TOP OF EXISTING UTILITY POLE 38.5't AGL MIN EXISTING PRIMARY 36,3't AGL EXISTING SECONDARY 31.5'± AGL - PROPOSED 1-1 /2" PVC RISER FOR POWER EXISTING GUY %"v'IRE 75.Ci't AGL EXISTING FIBER 25.0't AGL EXISTING C01�/IMUNICATION �4.0'+ AGL BOTTOM OF PROPOSED MOPT TERMINAL 21.7'f AGL PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD Y2 C-2E BOTTOM OF PROPOSED EQUIPMENT 12.0'f AGL (MINIMUM) _ BOTTOM OF PROPOSED LOAD CENTER 10.0't AGL (MINIMUM) BOTTOM OF PROPOSED METER 8.0't AGL (MINIMUM) BOTTOM OF PROPOSED RF SIGNAGE 8.0't AGL (MINIMUM) - EXISTING UTILITY POLE PROPOSED HIGH IMPACT - PVC CABLE COVER (BLACK) EXISTING G)\ADF i 1 UTILITY POLE ELEVATION -28 SCALE: 3/16" = 1'—u" (11x17 SIZE) 3/8" = V-0" (22 x34 SIZE) EXISTING GRADE 0.0'f AGL PROP( TERMINAL (E PAINTING NOTE: ALL PROPOSED EQUIPMENT SHALL BE PAINTED BROW XISTING FIBER LINE XISTING COMIM LINE )POSED VERIZON WIRELESS U-GUARD (CABLES FROM I TO ANTENNA) )POSED LC/UPC BIDI RUGGEDIZED :R JUMPER FROM THE PROPOSED :IT TERMINAL TO PROPOSED FUJITSU 3SIVE FIBER ENCLOSURE ►POSED VERIZON WIRELESS EQUIPMENT OUD (COMMSCOPE PN: SSC-760249586X1 X EQUAL) (SEE DETAIL 5/C-3) )POSED 1-1/2" CONDUIT OM SECONDARY TO METER) OPOSED RUGGEDIZED FIBER JUMPERS TO Hs AND MMUs IN THE SHROUD (TYP OF 2) ?OPOSED EATON BRP126100R )AD CENTER OR APPROVED EQUAL IN OPPOSITE SIDE OF POLE) OPOSED 1-1/2" LIQUIDTIGHT ETER TO LOAD CENTER) PPOSITE SIDE OF POLE) 'OPOSED METER MILBANK P/N: 048-RL OR APPROVED EQUAL (SECURE POLE USING ERICSSON SERIES PBAL )UNTING BRACKET OR APPROVED EQUAL) `- EXISTING UTILITY POLE ELEVATION DETAIL —2B SCA'_L: 2" = 1'-0" (11x17 SIZE) 1" - 1'—O" (22x34 SIZE) verizon "i 75 CALKINS ROAD I it Pr)rrESTER, NY 14623 i flectonic ..AmuL,SOLUTIoR&EXUP"ON LS.RVICE. T.etd E/+okiew10 Cenartw* Gedogletr t Lane 5lrwyon, Q.P.C. rrojsct Cc^loci info 36 bnt%eh American 81vc. Phore- (5'8 783-1G3J S J'te 101 ,800 829-6531 Lulhom. NY 12110 www.tectoricengmeenng.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP P kin MATT Icc11c C 05/06j26 FOR REGULATORY 1 0o/C9/26 ADDED FAINT NOTE UNAUTHORIZED ALTERATION OR ADDIT5ONS TO A PLAIT SEARING THE SEAL OF A LICENSED ENGINEER OR LAND LRVEYOR IS A VIOLA"ION OF SECTION 7205 SUED -VISION 2 OF T-Ic NFiV YORK STATE EDUCATION L' IV, COPIES OF THIS DOCUMEM WITHOUT A FACSIMTF 0= THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR ZED INK OF THE PROFESSIONAL ENGINEER OR L-.ND SURVEYOR. SHALL NOT 3E CONSIDERED V UD COPIES_ 0 1 ORIGINAL SIZE IN INCHES (22x34 FORIVAT) 0 ORIGINAL SIZE IN INCHES (11 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE POLE ELEVATION & DETAIL SHEET NUMBER ANTENNA (JMA P/N: CX160M1236—BF22) IA MOUNT SLEEVE (GIMBAL) ALFAB P/N: 900070) 'OLE MOUNT BRACKET CONCEALFAB P/N: 007951 )R APPROVED EQUAL) TILITY POLE 0 TO tJE VERIFIED IN FIELD POLE —TOP ANTENNA MOUNTING "-3 SCALE: %T3 I` A CAUTION A Transmitting Antenna(s) Radio frequency fields beyond this point MAY EXCEED the FCC Occupational exposure limit. Obey all posted signs and site guidelines. Call Verizon at 1-800-264-6620 PRIOR to working beyond this point. Site ID/ PSLC: verizon •` ACTIVE COMMUNICATION EQUIPMENT u1►+JIUYAPR0004t W74i M FT FfOtR2r31iTJILA>tD R V1ERTtf,•1 POMP VON%AkT[hM BY VT7<AM DWOWOMT MTR} OR CALL v [ Iambi V nRE'. E 55 rOR PMR a•aTT001M V44E EVER APPROACHW# "TrViA1ao" _rt 1lOKITIUTALAtq�­FT VUMCAI PIAAK CA- L tEF. Z0M WI R 3 S FT 1-I114l- 4QG FRl01l To CFfrtSTlr,G : �C _hVEGT �:�'C- NOTE: 1. CONTRACTOR TO FURNISH AND INSTALL PHENOLIC LABEL APPLIED TO LOAD CENTER. 2. ATTACH R:Y "CAUTION" AND "INFORMATION" SIGNAGE TO FACE OF UTILITY POLE USING 1'r WOOD SCREWS. 3. RF SIGNS ARE APPROXIMATELY 6"0.5" IN SIZE. - PROPOSED SIGNAGE SCALE: NTS POLE MOUNTING BRACKET —� (ERICKSON P/N: PBAL-12 OR APPROVED EQUAL) (TYP OF 2) / e r� -mil ,p 1p- 1 /4%1" WOOD SCREW (TYP OF 4/BRACKET) S.S. 1/4"-2Ox3/4" CARRIAGE BOLT, FLAT WASHER, & NYLON LOCK NUT (INCLUDED WITH BRACKET) PROPOSED METER SOCKET, MILBANK P/N/ U2048—RL (OR APPROVED EQUAL CONFORMING TO UTILITY COMPANY STANDARDS) METER MOUNTING DETAIL C-3 SCALE: NTS Metro Cell Solutions COMMSC�- PE SSC-760249586X1X MV2 Micro Radio Concealment Enclosure Universal Single Part Number Radio Enclosure Introduction One pale mou led Ratio Er c i . - •, re fr r a U ywr radio moons under a siroE Dan r, UiTlt er Hpfty contigurabde - swports varyrng conrigurations with a unhwwl mounting t solution • Aesftlicaa0F awwad trout ` r. • Accepts Rados Iron: • Ericssw radios SSC-760249586EIX Nokia radios SSC-760249586N i X Samsung ra(hos SSC-760249586S 1 X � Th= raoic __. ceairrler! e :cf^_ silpl su-e 1= deed to coriia +ea! smaj: cell -e ni " Jr-Te'd 10 wisl 1A MCiiJ) LOT..(C:C. i)1)., iS'_ _ Ili Al. --tJ'CS 81i wd ai vale replan ernerlts wrterc ,; _ :il Impact tt desired- UniQue, ant-.emaI internal rr•wunting s-,s,em • Can he k;tted with Rec6-5erz CorrrnScoCe diF.wexers and jumpers System Dimensioning & Configuration -:. i•__ ..-.- n�-!� -.!..i-. -iti •=i. ll«'".. :-rtr-, •tJ jr .i.�;F. ri+i;,i .._ , .C.. :.. its•. 1+._'; ._ i- 1041b► f43►_+]I with rip fifdC efx:,QFMrY. ,-'I•.; S;:t--, ;`.,i�'4 Approx 479tt 1276kgliciytoeded' (maxi •weipW vaned on oofilguraeon LAn. ,, Max f..:,ilrCattle Poia 00 2.5ira85 in 00 by ciarnIpr4 (Lwgrr dionew pales by steell bardtng) Mth het ded MWr&V kt) Up to 121n DID Wood Ada with irm:Jitded 511l- ftreaded rod for ttr k* booing UV-resntao powder eoaL Vanouc eako o0o is a, ailae!a Finish 'I- for Ligm Gary. -Y for Green -3- for 84m*, --C for Brown W fcw Fa)rfax Brown -F Federal Park Brown. 'T for hietaa"c SNw "W for W hte Bik-A 1-2) 2' Trade Sire Knockouts Paver: Fiber input Corduii Bat: (2) I Trade Saa KnockocRs Top: (2 ) 2' Trade Size Knockouts MC-SP-RENT-21-001-M NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. UTILITY POLE -� r'rCUt-UJ V Ghi t UN Dlzr- I LE ELECTRIC PANEL OR APPROVED E PROPOSED 1 /4%20 3/4" LONG BOLT (TYP OF 3) PROPOSED P1000T — UNISTRUT 6" LONG (TYP OF 2) PROPOSED 1 CHANNEL NUT (TYF PROPOSE[ L� 3 LOAD CENTER MOUNTING DETAIL SCALE: 4- = 1'-0" (11x17 SIZE) = 1•-0" (22x34 SIZE) Metro Cell Solutions COMMSC,. PE Ericaeon CordiOurations • (2) RRU1 VRRU!32R212s44154s2&4478 b (i) PSU AC OZW unim • (118843 or 4449 Dual Band RRU 6 t2) PSU AC 02'Oa units • (1) 9843 and (1) 4478 & (3) PSU AC 02V units • (1) 4415_ (1) 444{1 wid (1) 220%440x i (3) PSU AC 02'DB units • (1) 4455 and (1) •44413 d. 4 3) PSU AC 02.1% :slits • (1) 4440 and (2) 220x-440s 8121 PSU AC 0204 Lauts • Up to (61 Zn&K22052206 or 4402 440B radios • (1) 4415 or 4426 radea and (1) 220x$440x a (1) PSU AC 02i08 "I'Li tine Corrtpatibiltty for plot 320W C-Band Radio '• • 11 r 8863 a--.J I 1 I cN S-. a•r 11) 444y (4 ) PSU ACO8,11) (1) :SOX 19=-43 811) Raycap se "PTease e Ccrrtnscgpe for additionaf wriigurabom - sa--m Co"Norrad— • 01 or (2) 70Q'1l50 32M oval bard radio. t 1 r RT4401-48A CBRS radio. (1) RT2201- 46r1 LAA rA io, 0 l c1r (2b Dots 2 dk W DC rectifier. (1) SOX 1 o2f Q4W SDx 1426T-43 and (1) Raycep e 11) AWS+PCS AWS.'PCs 32OW dual band rode 11) RT4441.4aA CBRS radio. 01 RT2201j46A LAA radio, (1) Debts 2.0kW DC rectifier, (1) SOX11i260-43r SDX1926T- 43 and (1) Rsycao • 111 AWS-PCS or 7W.'85O 32OW duo ber-4 radio. 0116OW dual band radio (1) RT4401-48A CBRS radio. (1) RT2201-46A LAA radio. (1) or (21 Deu 20kW DC Racko, Cow"Itibil-dy rtcilf w. t t l SDX 1926U-43r SDX192UT-43 arxi 11) Raycap SSC-760249S86XIX . 11) or (2) 16OW dual band ratbm (1) RT4401-46A CBRS radio. (1) RT-701 -6A LAA todlo. (1) or iZ) Deka 2.OkW DC rechW (1) 9DX 19260-4N SDX 1926T-4 3 t 1 ! Rayow "PifCa-4ns--qr1r, rrprrsar AhV roradxfirtr:ar CO 5gnf ildOf s- Nokia Coefiprodons • 14) A scale Micro rziaim • 12) Dual Band Radios- 7&)VV and 320W phis tschfws S,upporfed dual band radios. "AHFiA "AHFIS "AHFIC '-AHLBA "AP48C.A "AHRCC "Al4 BBA supported Rectifiers, "Dolts "GE "CCI "Ndur FPAE **Pk;arrtr see Cormrrscnpr+ re6paisenri im far additional cn6gtmatiorss- tf • es-�os.re Ac runw mho Vo eornsa,c warts "=MI i asc�.:-as.v-.az-r•�rscx-f►rs>•_i�.r:.c•v �3.�:a,: • Ervvclt: car.:CrxprWaare C3r.►-s-_uor D M4e - llwx to -.SOX Mloc 43. 3Ct t?2CT.[1 • E,-:;,as rr rye: :oormwwn 0"W 194W t f w OF., rink reCW%M a CCI .screres, chi tecottM OR !•>•tle FPAE-acomwa.- rumor see rrnee�cr.�e r0PT2W 0&V* to dea t • 'x' 0W.4es i0Q-- -$ -roi LVII Glra. '.r +a Greer: -3- yr e.KA -4- F anfar erc•rt. T- F.eoe•a Pee sMW&. T tar Tar ''Al"r i �x MC-SP-REMI-21-003v04 r EQUIPMENT SHROUD DETAILS S•..l,'�: NTS SHOWN MOUNTED ON AN g'o POLE CLAMP. STRAP. AND THRU BOLT OPTIONS s.0 , t3.0 �, l jI (2) 2 TRADE SIZE KNOCKOUTS FOR CABLE ENTRY/ EXIT (CROSS CUT RUBBER GROMMETS INCLUDED) T-`• — RJLLY VENTED WITH GR487 + COMPLIANT PERF PATTERNS -tr f . �J i UNIVERSAL POLE—? REMOVABLE 24_Ll MOUNTING BRACKET Pi4NEL ACCESS 3-3 di ��777, y t-3 048.E TAtitPE? RESISTANT LATCH f ." _...Y-�... WITH PADLOCK HASP K 7' TRADE SIZE � KNOCKOUTS • ' �(?) 7 TRADE SIZE KNOCKOIJk, TAMPED. RESISTANT MTO SCREWS 4.0.— � � --r-• •-•• SSC-760249%6X1X 3:5747 11{ i METROCELL RADIO CONCEALMENT -- ! 6�.�r.V.E�;: A 1 CoMMSCC*APE . . • I— -- - --- verizon 1 175 CALKINS ROAD I ROCHESTER, NY 14623 ectonic PRArnuu SOLUTlottls. axatrr ON LL5111MCL Tectonic Enlmav ig Conu *-(t , Geologists • tmd Suvgors, D.P-C. Frnj•ct Cup-focf Info 36 86tish Amerl=n Blva. Fhone: (5'f3 783-1630 Suits 101 (800� 829-6531 Latham. NY 12110 www.tectomicengineen-ng.com WO NUMBER DRAWN BY REVIEWED BY 12861.115 LP I MP NO. DATE ISSUE 0 05/06/26 FOR REGULATORY 1 06/09/26 ADDED PAINT NOTE I UNAUTHORIZED AL ERATION uR ADDI?!ONS TO A PLAN BEARING THE SEAL OF A LICENSED EfGINEER OR LAND SLR'v?YOR IS A VIOLATION OF SECTION 7209 SLED VISION 2 OF THE NEW YORK STATE EDUCAi1ON LA'r1'- COPIES OF THIS DOCUMENT yi1THCUT A FACSIMILE OF THE SIGNATURE AND AN ORIGIMA'_ -EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAUD SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 01 1 ORIGINAL SIZE IN INCHES (22x34 FORI'',:AT) 0 ORIGINAL SIZE IN INCHES 111 x17 FORMAT) SITE INFORMATION ROOD & RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 SITE ADDRESS UTILITY PO LE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 ANTENNA MOUNT GROUNDING -, CONDUCTORS. #6 AWG STRANDED, , INSULATED AND COPPER CABLE, SECURED TO POLE AND ANTENNA \ MOUNT USING UV RATED CABLE TIES ANTENNA GROUNDING CONDUCTORS. #6 AWG STRANDED, INSULATED AND COPPER `y CABLE, SECURED TO POLE AND ANTENNA MOUNT USING UV RATED CABLE TIES PROPOSED VERIZON WIRELESS ANTENNA BOND MAIN GROUND TO NEUTRAL WIRE OF SECONDARY TRIPLEX PROPOSED INSULATED P-CLIPS/STRAPS OR E STAPLES PLACED 18" APART p� i PROPOSED HOME RUN GROUND- ' - PROPOSED WIRE, #2 AWG COPPER MOPT TERMINAL INSULATED OR #2 TINNED ' (BY OTHERS) PROPOSED - EQUIPMENT SHROUD PROPOSED LOAD CENTER PROPOSED METER #6 AWG INSULATED GROUND TO HOME RUN FROM ALL CABLES AND METALLIC OBJECTS PROPOSED 1 /2" HIGH IMPACT PVC U—GUARD (U—MOLDING) MOLDING TO COVER GROUND DOWN WIRE ALONG BOTTOM 8' OF POLE EXISTING GRADE -- c M „ PROPOSED GROUND ROD (TYP OF 2) 3 _ (SEE DETAIL 3/E-1) 's z s s" s 1- 011 UTILITY POLE GROUNDING DETAIL E—, SCALE: 3/16" = 1'-0" (1107 SIZE) 3/8" = 1'—O" (22x34 SIZE) Q z z w z COAX GROUND- �¢ - ANTENNA MOUNT KIT (TYP) �= __ --COMPRESSION CONNECTION BY CONTRACTOR (TYP) ;I I - SECONDARY i II I 'i I I ' 'I ' 'I I PROPOSED CALIBRATION CABLE I ANTENNA COAX JUMPERS I (TYP OF 16) ' i - - - - - - - - - - '--- -- --I----- - SMALL CELL C-BAND RRH I POWER ' I MODULE ��--- I -- -F-- - HI -BAND GROUND BAR WITHIN SHROUD DOUBLE C-TAP OR COLOR CODED -� LONG BARREL DOUBLE LUG CONNECTION WITH NON OXIDIZING COMPOUND (TYP) #6 AWG INSULATED GROUND TO HOME RUN FROM ALL CABLES AND METALLIC OBJECTS HOME RUN GROUND WIRE, #2 AWG COPPER INSULATED OR #2 TINNED RRH r POWER .4 MODULE I LOAD CENTER 0 METER SOCKET GRADE , GROUND ROD (TYP) GROUND LINE #2 AWG COPPER GROUNDING RISER DIAGRAM E-1 SCALE: NTS PROPOSED 100A METER SOCKET (MILBANK P/N: U2048-RL OR APPROVED EQUAL BY UTILITY PROVIDER) 100A METER BY UTILITY PROVIDER �. P P 1-1/2" CONDUIT W/ (3)# 1. CONTRACTOR TO ROUTE CONDUIT TO THE HEIGHT OF THE SECONDARY OHW AND SPOOL 10' OF CONDUCTOR ABOVE THE. CONDUIT. SPLICE TO SINGLE PHASE SERVICE TO BE r PERFORMED BY UTILITY PROVIDER. CONTRACTOR TO UTILIZE PENETROX -' --e0 --Z 0 EQUIPMENT SHROUD -54DC CABLE r 1 120/240V SUPPLY CABLE (TYP) PROPOSED VERIZON 1IRELESS ' nn n LOAD CENTER (EATON BRP1281 1 1 /2" C W/ (3) #1 P P P (OR APPROVED EQUAL) ON ALL ONE LINE DIAGRAM CONNECTIONS WITHIN METER SOCKET 5 E—, SCALE: NTS \DE )THERMIC WELD (TYP) GROUND ROD, COPPER CLAD STEEL ROD, MIN 5/8" DIA. X 8'-0" LONG (TYP OF 2) n Y 6' MIN NOTE: GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM VERTICAL. GROUND ROD DETAIL E-1 SCALE: NTS NEUTRAL BONDING SCREW PROPOSED LOAD CENTER (EATON P/N: BRP1213100R) PROPOSED GROUNDING ELECTRODE CONDUCTOR. #2 AWG STRANDED, INSULATED COPPER CABLE TO GROUND BUS LOAD CENTER GROUNDING E—� SCALE: NTS PROPOSED SMALL CELL -� C-BAND MMU (1) DC CABLE (DELTA P/N - ,} 3799423700-S) s r- (1) AC CABLE (DELTA / P/N 3799919300-S) RRH DELTA ADVANTAGE P P -� P AC/DC MODULE PROPOSED -� HI -BAND RRH ti DELTA ADVANTAGE P P AC/DC MODULE P RRH L (1) AC CABLE (DELTA P/N 3799919300-S) (1) DC CABLE (DELTA P/N 3799423700-S) verizon 175 CALKINS ROAD I ROCHESTER. NY 14623 Tecton'i*c nArnnci ,o*w ""W*q owl~ "dag A t toga Urw om D.P.c. Ffo;.ct Canted Info 36 Brltieh Ar ericon Blvd. Phone: (518) 783-1630 Suite 101 (800) 829-6531 Latham. NY 12110 www.tectomicangincering.corn WO NUMBER DRAWN BY REVIEWED BY 12861.115 LPIF MP AIA IIATC MCI IC 0 05/06/26 FOR REGULATORY 1 06/09/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEYV YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE - OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES (11 x17 FORMAT) ROOD &RIDDLE FUZE ID#: 17612418 MDG#: 5000993724 UTILITY POLE# NM 17/VZ 15 ALONG HENNING RD CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE ELECTRICAL & GROUNDING DIAGRAMS & DETAILS SHEET NUMBER E�l