Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2025095 144 Spring St. Verizon Utility Pole Updated Application
Transaction Record Fed & (EV TRACKING NO.: SHIP DATE: ESTIMATED TOTAL COST: 873503251603 Jun 24, 2026 33.73 USD From address Lisa Krutka YOUNG SOMMER LLC 500 Federal Street, 5th Floor Fl 5 12180 NY TROY US Phone:5184389907 lkrLitka@youngsommer.com To address Mark Graham, Admin. Asst. OPED City of Saratoga Springs 474 Broadway 12866 NY SARATOGA SPRINGS US Phone:5185873550 Package information Pieces Weight Dimensions (LxWxH) Carriage value Package options I x 1.00 lb n/a Packaging type: Service: Pickup / drop-off type: FedEx Envelope FedEx Nacional 10.30 a.m. I have already scheduled a pickup at my location Billing information Bill transportation cost to, ******419 P.O. No.: Bill duties, taxes and fees to: Invoice No.: Your reference: 11889.57 & 11889.96 Department No.: Please note: This transaction record is neither a statement nor ,in invoice, and does not confirm shipment tendered to FedEx or payment. FedEx %Nfill not be, responsible, for any claim in excess of $100 per package, %vhether the result of loss, darnage, delay, non -delivery, misdelivery, or Misinformation, unless you declare a higher value, pay an additional charge, document your actual loss and file a timely claim. Limitations found in the current FedEx SeRlice Guide apply. Your right to recover from FedEx for any loss, including intrinsic value Of the package, loss of sales, income interest, profit, attorney's fees, costs, and other forms of damage whether direct, incidental, Consequential, or special is limited to the greater of $100 or the authorized declared value. Recovery cannot exceed actual documented loss. IMaximurn for items of extraordinary value is $1000, e.g,, jewelry, precious metals, negotiable instruments and other items listed in our Service Guide, Written claims must be filed within strict time limits; Consult the applicable FedEx Service Guide for details. The estimated shipping charge may be different than the actual charges for your shipment. Differences may occur based on actual weight, dimensions, and other factors. Consult the applicable FedEx Service Guide or the FedEx Rate Sheets for details on how shipping charges are calculated. Young Sommer iFLh, � ATTO R N EYS AT LAW MAIN OFFICE FOR ALL MAIL): 500 FEDERAL STREET, 5TH FLOOR, TROY, NEW YORK 12180 ALBANY OFFICE: 41 STATE STREET, STE 604-12, ALBANY, NEW YORK 12207 Phone: 518-438-9907 o Fax: 518-438-9914 www.youngsommer.com June 24, 2026 Via header-aLT Mark Graham Administrative Assistant for OPED City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866 David C. Brennan, Esq. Writer's Telephone Extension: 224 dbrennan@youngsommer.com : Cellco Partnership d/b/a Verizon Wireless Application for DRB Approval Utility Pole No. NG 7-1 — ROW Adjacent to 72 Court St. Dear Mr. Graham: Please find enclosed a revised application to the Design Review Board for a proposal to add a wireless small cell antenna and equipment to a replacement utility pole in the state right of way (referred to internally as the "Spring Street Deli" site). Please note no additional application fee is included. Per our discussions, this is revised application previously proposed to be located in the ROW adjacent to 144 Spring Street, which fee was previously provided. We look forward to discussing this further with the Design Review Board at an upcoming meeting. In the meantime, if you have any questions concerning this letter or the enclosed materials, please contact me at your convenience. Very truly yours, David C. Brennan, Esq. E. Hyde Clarke, Esq. Encl. DESIGN REVIEW BOARD CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, NEW YORK In the Matter of the Application of CELLCO PARTNERSHIP d/b/a Verizon Wireless Utility Pole No. NG 7-1 Adjacent to 72 Court Street Saratoga Springs, New York 12866 APPLICATION FOR DESIGN REVIEW BOARD APPROVAL and STATEMENT OF INTENT Submitted by: Verizon Wireless Kathy Pomponio, Principal Engineer -Network Real Estate 175 Calkins Rd Rochester, New York 14623 (585) 321-5365 Tectonic Engineering & Surveying Consultants, P.C. Steven Matthews, P.E. 36 British American Blvd, Suite 101 Latham, New York 12110 (518) 783-1630 Airosmith Development Inc. Sara Colman, Site Acquisition Specialist 318 West Ave. Saratoga Springs, NY 12866 (518) 461-7114 Please Direct All Correspondence To: Young/ Sommer LLC David C. Brennan, Esq. 500 Federal Street, 5th Floor Troy NY,12180 (518) 438-9907 Dated: June 24, 2026 DESIGN REVIEW BOARD OF THE CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORK In the Matter of the Application of CELLCO PARTNERSHIP d/b/a Verizon Wireless Premises: Utility Pole No. NG 7-1-Adjacent to 72 Court Street Saratoga Springs, New York 12866 STATEMENT OF INTENT and APPLICATION FOR DESIGN REVIEW BOARD APPROVAL I. Purpose and Need CELLCO PARTNERSHIP d/b/ a Verizon Wireless ("Verizon Wireless" or the "Applicant") proposes the collocation of an unmanned public utility/ personal wireless service facility (a "communications facility") at the above location. More specifically, Verizon Wireless is proposing to add wireless telecommunications equipment to the proposed replacement utility pole. The Applicant proposes to install on a replacement utility pole: a single, cylindrical antenna (approximately 24" tall x 14.6" in diameter) mounted at the top of the pole at a tip height of 42.3± feet along with the installation of electric and telecommunications equipment on the utility pole at a minimum height of 8' above grade. All proposed equipment will be painted brolm as noted on Slieet C-2B and consistent zvith prior DRB approvals for sinzilar projects. The existing utility pole measures 32.0± feet in height, and the proposed utility pole measures 38.5± feet. The property is located in the right of way adjacent to 72 Court St., City of Saratoga Springs, Saratoga County, New York (NG 7-1). [Zoning Site Plan Drawings of Tectonic Engineering & Surveying, PC at TAB 6] . Upon completion, the proposed facility will provide additional wireless network bandwidth and improved performance to the nearby roads and the surrounding neighborhood areas, as shown in the accompanying coverage maps. More specifically, the site is proposed improve coverage and network performance along the surrounding portion of Court St. and the local roads and homes generally surrounding the proposed facility including portions of Phila St., Spring St., Regent St., and Nelson Ave. [Proposed Coverage Map at TAB 3]. Verizon Wireless is considered a public utility for land use purposes under New York decisional law (Cellular Telephone Conipan y v. Rosenberg', 82 N.Y.2d 364 [1993]), and a provider of "personal wireless services" under the federal Telecommunications Act of 1996 (the "TCA"). Verizon Wireless' equipment will be in operation twenty-four (24) hours a day, seven (7) days a week, three hundred sixty-five (365) days a year. 1 In Rosenberg, the State's highest Court detennined that the ordinary variance standard is inapplicable and a cellular telephone company applying for relief need only show that (1) the relief is "required to render safe and adequate service," and (2) there are "compelling reasons, economic or otherwise," for needing the variance. Cellular Telephone Co7npany v. Rosenberg, 82 N.Y.2d 364, 372 (1993). Verizon Wireless is applying for review by the Design Review Board.2 The proposed replacement pole is located in the UR-3 Zoning District. The facility is located in the Historic Review District but is not located in the Architectural Review District. The proposed communications facility is unmanned and will be visited for routine maintenance purposes approximately two times per year (only as needed). As such, the project will not have any impact on existing water and sewage services. In addition, neither pedestrian nor vehicular access to the premises will be impacted [see Zoning Drawings at TAB 6] . II. Compliance with City Requirements The proposed communications facility complies in all material respects with City requirements: 1. SEQRA: A Short Environmental Assessment Form is attached as TAB 2. 2. Minimum Visual Impact: As noted above, Verizon Wireless' proposed facility is designed to have a minimum possible visual effect on the surrounding community and neighborhood [TAB 4] . 3. Site Plan: The Applicant has provided a Zoning Site Plan that identifies the proposed improvements [TAB 6]. Based upon the foregoing, Verizon Wireless respectfully submits that approval is appropriate in this case. III. Conclusion The communications facility proposed is a public necessity under Rosenberg in that it is required to render adequate and safe service to this area of the City of Saratoga Springs. In an effort to supplement existing telecommunications services to this area of the City, while reducing the need for a new tower or macro cell collocation, Verizon Wireless has identified an appropriate location for the deployment of a small cell facility. Verizon Wireless' existing macro cell sites in the area do not provide adequate coverage and capacity to this area of the City. The City of Saratoga Springs will be lacking adequate and safe capacity, and the failure to approve this application will eliminate the means to provide necessary capacity. This, combined with the federal mandate to expeditiously deploy advanced wireless services across the nation and Verizon Wireless' FCC licenses to provide such services in the City of Saratoga Springs, demonstrates that Verizon Wireless' facility is a public necessity. Without the construction of the communications facility proposed, the public would be deprived of an essential means of communication, which, in turn, would jeopardize the safety and welfare of the community and traveling public. The small cell facility will not be noticeable to the traveling public or nearby property owners. The communications system proposed has been sited to have the least practical adverse 2 For the reasons set forth herein, Verizon Wireless believes that its project complies in all material respects with the provisions of the City of Saratoga Springs Land Use Laws and, consistent with the application process established by the City for prior Small Cell applications, that no additional approvals or relief are required. To the extent that an additional approval or relief is required, Verizon Wireless submits these materials in support of such approval(s). 2 visual effect on the environment, and any resulting impact(s) may properly be considered as minimal in nature and scope. Attached to this Application and Statement of Intent are the following: 1) An Application for Architectural/Historic Review by the Design Review Board; 2) A Short Environmental Assessment Form; 3) Radio Frequency Coverage Plots: 4) Photosimulations of the proposed installation and SEQRA Visual EAF Addendum; 5) Radio Frequency - Site Compliance Report; and 6) Project Zoning Drawings. Kindly place this matter on the agenda for discussion at the next available meeting of the Design Review Board. In the meantime, if you should have any questions or require any additional information concerning this project, I can be reached at (518) 438-9907. Thank you for your consideration. Respectfully submitted, CELLCO PARTNERSHIP d/b/ a Verizon Wireless David C. Brennan, Esq. Regional Local Counsel Dated: June 24, 2026 [FOR OFFICE USE] "-'FIANDWRITTEN APPLICAT IONS WILL NOT BE ACCEPTED" CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEVV YORK 12866-2296 TEL: 518-587-3550 X2533 wwm sa ra toga -springs. org APPLICATION FOR: ARCHITECTURAL/ HISTORIC REVIEW (Applicatiori #) (Project Title) Staff Review APPLICANTS}`'` OWNE.E(�J ff no- 2,pplicantl' N-FTORNEY/AGENT Name Cellco Partnership d/b/a Verizon Wirele! National Grid David C. Brennan, Esq. Address 175 Calkins Rd 300 Erie Blvd West Young/Sommer LLC, 500 Federal S Rochester NY 14623 Syracuse NY 13202 5th FI, Troy NY 12180 Phone 518-714-9282 15 18-869-2299 Email Identify primary contact person: 0 Applicant ® Owner 77, Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: El Owner 9 Lessee El Under option to lease or purchase PROPERTY I NFORMA I —ION ROW Ad to 72 Court Street Property Address/Location: J Tay, Parcel #-. _IWA - - (fbt- example: / 65.52 - 4 - 37) Date Acquired by Owner: a I U R 3' Curl Zoning District: Property use: 0 Residential 0 Non-residential/mixed-use Type of Review: EJ Architectural IM Historic 0 Extensi o n/mod ifl cation (of current approval) Summary description of proposed action: Collocation of unmanned public utility/personal wireless service facility on a replacement wooden utility pole with an antenna tip height of 42.3 +/- ft. Has a previous application been filed with the DRB for this property? M No 11 Yes — date(s)? Note, a past application was proposed for the ROW adj' is acent to 144 Spring Street, this application serves to replace that prevl'OLls application. - App. No. (s)? Revised 12/2025 and I electronic of application& LL other --A "complete" application consists of I hard copy (original as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties Q A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 1 7")(1 I " sheet. LJ Elevation drawings showing design of all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'A' sheet — smaller permitted if legible 11 Floor plans for proposed structure; on sheet no larger than TO smaller permitted if legible '71 Product literature, specifications and samples of proposed materials and colors Chance in exterior building materials (windows, doors, roof., siding, etc.), or color (in non-residential districts only) 0 COiOiphotographs showing site/exterior details of existing structures and that illustrate affected features r� Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp r type, wattage), etc. - include compass bearing & scale-, no larger than 2A' sheet — smaller permitted if legible E .] Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR- I St FIST-HTR=30'; UR-4=25% UR-2, UR-3 & NCUD-1=10') Installation, removal or change in material of drive- and walkways 4- Installation or removal of architectural, sculptural or vegetative screening over 3" in height Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: 11 Color photographs showing site/exterior details of existing structures, and of adjacent properties n Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2'x3' sheet — smaller preferred if legible 11 Product literature, specifications and samples of proposed materials and colors Sign4ge / Awnings El Color photographs showing site/exterior details of existing structures, and adjacent properties ® Plan showing location of proposed sign/awning structure on building/premises: no larger than I I "x 17" 0 Scaled illustration of proposed sign/awning structure and lettering (front view & profile); include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Cl Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location 11 Product literature, specifications and samples of proposed materials and colors 0 Color photographs showing site/exterior details of existing structures, and of adjacent proper -ties El Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale ® Written description of reasons for demolition and, in addition: El For structures of "architectural/historical significance", demonstrate "good cause" why structure cannot be preserved El For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing" structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities R Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions-, colors, materials, lighting, mounting details ® Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 12/2025 Request for extension of current nproyal ® Identify date of original DRB approval: Cur -rent e)"piration date: Org. App. No. 0 Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood, SEQR Environn-iental Assessment Form L'J-- Applicants proposing the following must complete "Part I" of the SEQR Short Environmental Assessment Form (available here: http: de.c.ny.gov/,docsjp,errnits_ ej op rations pdf/sgaf -p f partone 0) , - Construction or expansion of a multi -family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Di-qrInstire Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? ® No 0 Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application, Certifica'don I/we, the property owner(s), or purchaser(s)/Iessee(s) under contract, of the land in question, hereby request an appearance beforen, the Design Review Board. By the signature(s) attached hereto, 1/we certify that the information provided within this application and accompanying documentation is, to the best of my/our k1nowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application, Furthermore, I/we agree to meet all requirements under Article V11 for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs, Date: tAnnlir;int signature) Date:6/24/26 (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign, Owner Signature: Owner Signature: Date., Date: RerjSed 12/2025 't►cr `, /' CITY OF ARATOGA SPRINGS 7r DESIGN REVIEW BOARD City Hall - 474 Broadway Saratoga Springs, New York 12866 PRPOR A VC, U Tel: 518-587-3550 X'2_533 wmAi.saratoga-springs.org 6 INSTRUCTIONS ARCH ITECTURA L/ HISTORIc RE\AEwAPPhi CKfi0N ELIGIBILITY: An applicant to the Design Review Board for Architectural Revievv or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the proper cy in question. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRB wM only consider properly completed applications that contain I alrdiudl I&- of the application and ALL other required materials as indicated on the application. 14 M-411,. "v/V"_RJTTEN APPLICATIONS WILL NOT BEACCEPTED11 3. ACTIONS REQUIRING REVIEW: Arc'nitectul)-al RevaP_\A/, District Historic Review District o any exterior changes that require a building permit InstAlation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure any material change to exterior of a structure including: demolition of a structure- addition or removal of exterior architectural features installation, removal or material changes to exterior Within a non-residential zoning district: building elements such as roof, siding, windows, doors, a change in exterior building color porches, etc. installation of an awning enclosure or screening or buildings openings Such as windows, doors, porches, etc. installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: installation, removal or material changes to drive- or walkv,/ays installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter a change in exterior building color within a non- r residential zoning .esi district a new, or change to an existing, sign or awning installation of telecommunications facilities Note - Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. .......... Revised 12/202-5 14. DESIGN GUIDELINES: The Design Review Board will evaluate whether the proposed action (construction, alteration or demolition) is compatible%with existing s and surrounding properties using the following criteria: structures o Height — consistent with historic form and context of site and surrounding properties a Scale — relationship of struojure and its architectum.] elements to human size, form, perception o Proportion — relationship among building elements including front facade, windows, and doors o Rhythm — pattern resulting from repeating building elements such as door/ -window openings, colun-ins, arches, and other faqade elements a Directional 'Ex"pression — compatibility with horizontal & vertical expression of surrounding structures (-.-, J\ g, Massin g & Open Space — relationship of structure to open Space bemteen it and adjoining buildings • Setback — compatibility with surrounding structures • Compatibility of the following NAfith surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Bufl.dina6 materials - Color--- (in non-residential zoning districts only) ,5. 1 M01FIS, Or disapprove an -appiication, PECISIONS: The Design Review Board may approve, approve vtith conditions, C& L The DRC innay impose appropriate conditions and safeguards in connection with its approval inciuding6 natuire/ quality of materials, manner of construction, and design. An applicant may an p�a! a. denied F)RC application on the grounds of hardship. Application approvals shall expire vvithin .18 months of the filirig date unless the project ha.S SUfficiently commenced (i.e. buildinjRdemolition permits obtaimad and construction/alteration begun-,). Applicants may i-eqUest up -Co 2, extensions if requested be-iore e,-0_-1,.pi ration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratogamsprings.orF) for.meeting dates. Applicatio-ns are placed on an agenda on first -come, first -served basis as determined by the completeneSs of the application, 7. APPLICATION FEE (NON- REF UNDAB LE): Make checks payable to the "Commissioner of Finance" REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUIMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Desip Review Board responsibilities maybe f-bund in ithe City's Unified Development Ordinance aNratlable in City Hall and on the CitY "s NAveb site at https://r.iy-saratouaspri.i-igs.cix,-iCPILLs.coiii/DocuiiieritCel-itei-/ View/17803/Full-UDO Revised 12/2025 City of Saratoga Springs OFFICE OF PLANNING AND ECONOMIC DEVELOPMENT FEES - 2026 Application to City Council FEE Comprehensive Plan Amendment $1,800 + $300/acre Zoning Ordinance Amendment $800 + $300/acre Planned Unit Development (PUD) Amendment $800 + $3001acre Application to Zoning Board of Appeals FEE Use Variance $1,400 + $75/app Area Variance - Residential (1 & 2 Family) $350/1 st var + $75/app + $150/ea add variance Area Variance - 3+ Family and Commercial $1,000/1st var + $75/app + $2001ea add variance Interpretations $650 + $75/app Post Work Application Fee Application Fee x2 + $75/app Variance Extensions 50% of Application Fee + $751app Demolition $500 Residential Structures -- 1 or 2 Family Principal or Accessory Structure_ ~� (Materials Change - roof, windows, siding $75 Fagade Change - removalfaddition of windows, doors, porch $150 Addition or new construction $300 Approval Extension 50% of Application Fee 3+!Multi-Family, Comm, Mixed -Use Principal or Accessory Structure Equipment Install or Materials Change - roof, windows, siding, paint color $150 Signs, awnings $150 Fagade Change - removal/addition of windows, doors, porch $300 Addition or new construction $650 Approval Extension or Modification 50% of Application Fee Post Work Application Fee Application x2 Application to Planning Board Special Use Permit $1,200 + $75lapp Temporary Use Permit $500 Special Use Permit - Extension $400 Special Use Permit - Modification $550 + $75/app Site Plan Review - incl. PUD Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non -Residential / Mixed -use $800 + $150/1,000 sf (Non -Res) + 250 unit (Res) Administrative SPR Residential $400 Non -Residential / Mixed -use $800 Extension Residential $250 Non -Residential 1 Mixed -use $350 Subdivision - incl. PUD Sketch Plan $400 per sketch Preliminary Approval Residential: 1-5 hots $700 + $75/app Residential: 8-10 Lots $1,100 + $75lapp Residential: 11-20 Lots $1,450 + $75lapp Residential: 21+ Lots $1,800 + $75lapp Residential - Extension $350 Final Approval Residential $1,550 + $200/lot + $75/app Non -Residential $2,400/lot + $75lapp Final Approval Modification Residential $400 + $75/app Non -Residential $800 + $75/app Final Approval Extension Residential $250 Non-Residentiai $350 Subdivisions and Site Plans are subject to Engineering Review- See DPW Fees Other Lot Line Adjustment/Subdivision Administrative Action Letter of Crcdit —Modification Extension Letter of Credit - Collection Recreation Fee Land Disturbance activity Permit Watercourse/Wetiand Permit Watercoursei'VVetland Permit Extension SEQRA EIS Review (Draft & Final) Sidewalk Fee Lieu Tree Removal $400 $400 LAP to 1 °� of LoC $2,OOOflot or unit $750 + $35/acre $750 $350 TBD See DPW Fees Avg. nursery cost in caliper of new species equivalent to diameter at breat height (DBH of tree(s) Removed � 5..Hfo,� Lvitd L�110 ��;� � �� ' �11'- `%�L Part 1 — Project lnfarnne2t1on. The applicant or project spoK�sul° is Lresponsible for he completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current informatloll. Complete all items in Fart 1. You may also provide any additional i��formation you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part I — r-Lr C1)jof,t 2nd' �ns'r'L I.` E--ififeR`ti1�-aIlan, Name of Action or Project: Cellco Partnership, d/b/a verizon wireless - Unmanned Wireless Facility - "Spring Street Deli" Project Location (describe, and attach a location map): Fight -of -way adj J. to 72 Court St, City of Saratoga Springs, Saratoga County, NY 12800 Brief Description of Proposed Action: ' Cellco Partnership d/b/a verizon Wireless ("Verizon Wireless" or "Applicant") is proposing an unmanned wireless communications facility on a proposed replacement wood utility pole on Court St. The subject pole is located on the East side of the right -or -way of Court St, approximately 150 Noah of Spring St. In general, the installation consists of the following: one (1) antenna mounted at a centerline height of 41.3' above grade on a proposed 38.5' (42.3' including antenna height) tail replacement wood pole. All accessory equipment, cabling and utility services (power and fiber) are proposed to be mounted to the wood pole. Name of Applicant or Sponsor: Telephone: 585 321.5435 I:- . - Lmail: Kathy.pomponio�«�veriZonwireiess.com � Cellco Partnership d/b/a verizon \Alireless; attn: Kathy Pomponio Address: 175 Calkins road City/PO: State: Lip Code: Rochester NY 14623 1. Does the proposed action only involve the legislative: adoption of a plan, local law, ordinance,NO YES administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that may be affected in the municipality and proceed to Part 2. If No, continue to question 2. p _w_ _ ._... __...._.._ W__ _..___.._ �.—_......... _.._.___.�.......W....._....._ _ ._._ ___.._._..___.__....._..._._._......_._...._..._._._......____........._.._._..—.__._..,__._._............. ... _.... _..... _...__...._ 2. Does the proposed action require a peniiit, approval or finding from any other government Agency`:? NO YES If Yes, list agency(s) name and permit or approval: City of Saratoga Springs - Design Review Board approval; Building permit 3. a. Total acreage of the site of the proposed action? <0.0001 acres b. Total acreage to be physically disturbed`? <0.0001 acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor`? <0.0001 acres 4. Check all land uses that occur on, are adjoining or near the proposed action: Urban Rural (non -agriculture) ® Industrial Con-ime,-cial ED Residential (suburban) F±1 l Forest Agriculture ❑ Aquatic Q Other(Specify): Saratoga Race Track Parkland 'age 1 of 3 SEAF 2026 5. is the proposed action., ��^ .�...T a. A permitted use under the zoning regulations'? b. Consistent with the adopted comprehensive plan? NO YES N/A E]- E1_ 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? NO YES ✓ 7. Is the site of the proposed action located in, or does it adioin, a state listed Critical Environmental Area? If Yes, identify: NO YES 8. a. Will the proposed action result in a substantial increase in traffic above present levels? b. Are public transportation services available at or near the site of the proposed action? c. Are any pedestrian accolnn-iodations or bicycle routes available on or near the site of the proposed acti on'? NO YES ✓ 9. Does the proposed action meet or exceed the state energy code requirements? If. the proposed action will exceed requirer rents, describe design features and technologies: NO YES 10. Will the proposed action connect- to an existing public/private water supply? If No, describe method for providing potable water: Proposed action does not require a potable water supply. NO YES 11. Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: Proposed action does not require wastewater treatment. NO YES 12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district which is listed on the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and I--listornc Preservation to be eligible For -listing on the State Register of Historic Places? The project is located within the East Side Historic District. b. Is the J ro'ect site, or an ortion of it located in or ad:' acent to an area desi hated as sensitive for P any .I g archaeological sites on the NY State Historic Preservation Office (SI- PO) archaeological site inventory? NO YES ✓ 13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies .regulated by a federal, state or local agency? b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feat or acres: NO YES Page 2 of 3 SEAF 2026 14. Identify the typical habitat types that occur on, or are likely to be found ^on the project site. Check all that apply: ❑ Shoreline ❑ Forest �.gri' ❑ culturallgrasslands Early mid -successional ❑ wetland Ci Urban Suburban 1.5. Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or Federal government as threatened or endangered? NO YES 21 F] 16. Is the project site located in the 100-year or 500-year flood plain? NO YES Z E_ 17. will the proposed action cI'eate storm water discharge, either from point or non -point sources? If Yes, a. will storm water discharges flow to adjacent properties? b. Will stone water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: NO YES F El 18. Does the proposed action include construction or other activities that would result in the impoundment of water or other liquids (e.g., retention pond, waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment: NO YES 19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste management facility? If Yes, describe: NO YES 121 20.Has the site of the proposed action or an adjoining property been the subject of remediation. (ongoing or completed) for hazardous waste? If Yes, describe: The project site is located 0.24 miles southeast of the Saratoga Springs Lake Ave MGP site. NO YES 21. Is the project located within, or within '/Z mile of, a disadvantaged community? If No, could impacts from the project affect a disadvantaged community? If Yes to either question in 21, answer the following question. a. Identify the potential pollution impacts of the project, either direct or indirect, that may occur within the disadvantaged community (e.g., wastewater discharges, air emissions, noise, odors, solid or hazardous waste generation or management): NC7 YES � I CERTIFY THAT THE INFGRMAUON PRGVIDE:D ABOVE I'S TRUE AN'D ACCURATE TO THE BEST OF MY KNOWLEDGE Applicant/sponsor/name: Steven Matthews, agent on behalf of applicant Date: 6/15/2026 Signature: Attvm matt'a-" Tit : Director of Engineering Wage 3 of 3 SEAF 2026 EAF Mapper Summary Report Monday, June 15, 2026 1:07 PM Disclaimer: The EAF Mapper is a screening tool intended to assist r� - .: y •[,� �,� [._2 � r. 2: .$_-`- project sponsors and reviewing agencies in preparing an environmental 'U 1-`[ �.w assessment form (EAF). Not all questions asked in the EAF are h;•..t> :'.. 65; answered by the EAF Mapper. Additional information on any EAF . _5 H question can be obtained by consulting the EAF Workbooks. Although bILI the EAF Mapper provides the most up-to-date digital data available to 4 ' ld �1 1� `il DEC, you may also need to contact local or other data sources to by Mapper to data by . �► iEll -'1-1 `�<« - 'I•�r �'-`1'"` confirm data provided the or obtain not provided the Mapper. n _ � "�•' •r'. •� 1 f]�� 1 '� I1 � 1. FAT .I. - ►' ^ 4� Fr�l�rynI _ Fair tip,inn. p �. ..�--�• I Q� 1 '1� =a.. iN.,rnlll�n Koq-41C.r.nr .,�' I 5. - --��• - ,�� ,\r.f, �:n Buffalo li =` '1�►l' Alhnra ti'y`� e.- ^r �' ,lit S ��z, r� � � ; Ef r H ERE G .,rl '�i n, US q, I I't ���`�. ": -� '��� RQ ] f� 1 l' �j '`-• �1 ' �> Esn rsi � _Itih—a '• ��° '" "I, - •1 `� '(- �'r� ". _ r t, I 1 � r �i �'- l ,1�1i^''� ' � � �r'i i 'P?� '�,� �L? ,i .rr��. T {A � -I ` I , � •�Yr � ' lr - _ � �•��'�l Ili � � ' " r r -: r � � '::1 b' = :q _ ,- r I�11ti� f � h� , E5 H ERE �;�ti• rn, i� ►, �;: �_• --I , N P Part 1 / Question 7 [Critical Environmental No Area] Part 1 / Question 12a [National or State Yes Register of Historic Places or State Eligible Sites] Part 1 / Question 12b [Archeological Sites] No Part 1 / Question 13a [Wetlands or Other Digital mapping data are not available or are incomplete. Refer to EAF Regulated Waterbodies] Workbook. Part 1 / Question 15 [Threatened or No Endangered Animal] Part 1 / Question 10 [100 or 500 Year Digital mapping data are not available or are incomplete. Refer to EAF Floodplain] Workbook. .... ........... .......... ........ . Part 1 / Question 20 [Remediation Site] Yes Part 1 / Question 21 [Disadvantaged No Community] Short Environmental Assessment Form - EAF Mapper Summary Report I ir O N aim . 1 jb I 1 ~ ►lob do •' _ T z _t: � ,� - ° ,ti, " ±' "y � •• r+ � �' y'� -•` � Kew` . Mi 4,7 WA �.� sue! Z.e�.{ '•i +yam• }t -rir. r •� • 1�• , oAW '# ILI INV rl • � �-. .vf'y, J � j . .4� •. �.� �I:i I.. y� ,� ' � "fit l -.!` \ \ �'.. ♦ . _.T ��.y ' . � •jam � • � �-' ♦' i .. ' "•, . - rt v` "1�w A4 .r . ;� •/. � • 1 _ �{._� i' t . may. • `� r' s a_ • '• �. ^iw. '+.'del ,.-ram - :' ' i �:•,.� � K ,�• .Yk,�. .r ®. a. 'I ••� _ ., . , Looking West facing 72 Court St • Proposed installation will be visible from this location. PM1 Distance from the photographic location to the proposed site is 40'± 12861.035A - � •'�" t hit .• �d• ,� ' - � � r� 111��Y• � I• 1 qo 14, iA •sc7 .,� •6K.;i _? 1�( '. �'. ".''- - i• j parr , ,.�1,�` _ _ �•/� � • ► '` V 10'.,ii'/%"•�.4 .} • . - - '�"�'wpm=i r �, • 0_+'7 '�f• yam •► � • � • 'ti ,�.. ,— � .w, ,T— ice. r�.c.. .. `.' •, .rn , �, rt ,+ %,IF w t Looking West facing 72 Court St Tectonic Proposed installation will be visible from this locatic Distance from the photographic location to the prop 6 17.2 0 Apparanidix B Environnrtlan,"-1 Quality Review VISUAL EAF ADDENDUM This form may be used to provide additional information relating to Question 11 of Part 2 of the Full EAF. (To be completed by Lead Agency) Distancrat V, a.,i b i it Pr9:1e,.-.-t and Resource (in 1. Would the project be visible from: 0 - '/4 /4- ,2 3- 5 5-1- A parcel of land which is dedicated to and available N/A to the public for the use, enjoyment and appreciation of natural or man-made scenic qualities? An overlook or parcel of land dedicated to public N/A 1:1 El 11 observation, enjoyment and appreciation of natural or man-made scenic qualities? East Side Historical Distric(#72; #60; #58; #82; #85 #87 Court St A site or structure listed on the National or State #135 Spring St El El Registers of Historic Places? State Parks? NIA E] E] The State Forest Preserve? N/A EJ I National Wildlife Refuges and State Game Refuges? N/A National Natural Landmarks and other outstanding N/A 17atural features? National Park Service lands? N/A Rivers designated as National or State Wild, Scenic N/A or Recreational? Any transportation corridor of high exposure, such the Interstate System, N/A as part of or Amtrak? A governmentally established or designated interstate NIA or inter -county foot trail, or one formally proposed for establishment or designation? A site, area, lake, reservoir or highway designated as NIA scenic? Municipal park, or designated open space? NIA County road? N/A I State road? N/A I Local road? Spring St; Court St; Phila St; El El 1:1 El 2. Is the visibility of the project seasonal? (i,e., screened by summer foliage, but visible during other seasons) OYes 2 No 3. Are any of the resources checked in question I used by the public during the time of year during which the project will be visible? ElYes No cirmcet USA Verizon Wireless Site Compliance Report Site name - Spring Street Deli Site Name: Spring Street Deli Site Address: Adjacent to 72 Court Street, Saratoga Springs, NY, 12866 Structure Type: Utility Pole Report Information Report Date: May 22, 2026 Report Generated by: Mamta Verna Customer Contact: Rick Andras Compliance Statement Verizon Compliance Statement: Verizon Wireless is compliant with FCC rules and regulations in all publicly accessible areas. o. of NEIV ES Cp� �,`Q•G�PEtL,� r n Z 086838 ROFESSO�P David C. Cotton, Jr. Licensed Professional EnginVeir State of Newyork, 086838 Date: 2026=May=29 Warning: It is a violation of New York State Law, Article 145, Section §7209 for any person, unless acting under the direction of a licensed professional engineer, to alter this document in any way. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA 9 19422 circet USA Contents 1. Executive Summary........................................................................................................................................................3 2. Antenna Inventory.........................................................................................................................................................4 3. Analysis...........................................................................................................................................................................5 4. Appendix A: Reference Information............................................................................................................................... 6 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA * 19422 c.rcet 1. Executive Summary Verizon Wireless has contracted with Cireet USA, an independent Radio Frequency consulting fin-n, to determine if the proposed telecommunications facility is in compliance with Federal Coirununications Conunission (FCC) rules and regulations regarding RF exposure as defined in 47 CFR § 1.1307(b) and 1.1310. This document and the conclusions herein are based on the information provided by representatives of Verizon Wireless which is assumed to be true and correct. All information used in this report was analyzed to determine compliance in publicly accessible areas, in particular at ground level. The analysis evaluates the telecommunications facility with respect to the General Population/Uncontrolled Maximum Permissible Exposure (MPE) limits. Circet USA has taken into consideration the Verizon Wireless antenna system as well as any existing antenna systems at the subject location. Verizon Wireless final antenna count is (1) antenna. Based on the analysis, Circet USA has determined that: Verizon Wireless is compliant in all publicly accessible areas with the FCC rules and regulations governing human exposure to RF electromagnetic fields as described in 47 CFR § 1.1307(b) and 1.1310. With the proposed Verizon Wireless antenna configuration in service, the composite exposure from this facility in all areas at ground level will be less than 1 % of the General Population MPE limit, or over 100 times less than the maximum allowed exposure in publicly accessible areas. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell e PA • 19422 c rcet USA 2. Antenna Inventory The table below contains data provided by Verizon wireless representatives and/or gathered by Circet USA personnel. This data was used to perform the U exposure analysis. Ant ID Owner Antenna manufacturer Antenna model Mech. Tilt (0) Azimuth (0) Height (ft) Frequency band Elec. Tilt (0) HBW (0) VBW (0) Total power (Watts) Gain (dBd) ERP (Watts) 1 Verizon CommScope V4S4-360S-BF2 0 10 41.3 LTE 1900 2 360 18.6 63.5 8.64 465 1 Verizon CommScope V4S4-360S-BF2 0 10 41.3 AWS3 LTE 2100 2 360 18.6 190.6 9.01 1518 1 Verizon CommScope V4S4-360S-BF2 0 10 41.3 NR 3.7GHz 2 360 1 8.6 142.9 8.7 1059.62 (Votes: Each row with the some number in the Antenna ID column references the same physical antenna. Power values provided by the client and used in the analysis may be greater than what is initially deployed. 80% TDD Duty Cycle and 1000/0 FDD Duty Cycle are used. Jumper/connector/coax loss between RRHs and antenna AWS/PCS: 2 dB C-Band: 2.5 dB e 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 1 circet USA 3. Analysis Circet USA has included the Verizon Wireless antenna system at the subject location in the analysis. All existing and proposed antennas are listed in the antenna table above. Engineering assumptions were used when specific antennaoror operating parameter information was not available for the other existing collocated antennas (if applicable). Using this data, software modeling using IXUS software was performed for all transmitting antennas located at the site. Circet USA has assumed a 100% duty cycle and maximum radiated power. The site has been modeled with these assumptions to determine the maximum potential RF energy density at ground level. Circet USA believes this to be a worst -case analysis based on the best available data. As stated previously, based on this analysis, the calculated ground level exposure from the Verizon Wireless antenna system alone is less than 1 % of the General Population MPE limit. Keep in mind that the FCC did not arbitrarily establish their own standards but rather adopted the recommendations of national and international organizations such as the National Council on Radiation Protection and Measurements (NCRP), the American National Standards Institute (ANSI) and the Institute of Electrical and Electronics Engineers (IEEE). These recommendations were developed by expert scientists and engineers following extensive evaluation of the potential biological effects from RF exposure. The FCC MPE limits are based on thresholds for known adverse effects, and they were designed to provide a substantial margin of safety. There is a safety factor of 50 built into the General Public MPE limits, and the predicted Verizon Wireless exposure levels are over 100 times below these very conservative limits. In cases where such compliance exists, the subject of electromagnetic field safety is preempted by the Telecommunications Act of 1996, which states: "No state or local government or instrumentality thereof may regulate the placement, construction, and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply with the (Federal Communication) Commission's regulations concerning such emissions." The graph below provides a visual depiction of the rather insignificant electromagnetic field exposure contribution from the Verizon Wireless antenna system out to a distance of 500' from the base of the structure. This portrays how low the Verizon Wireless contribution is when compared to the General Population MPE limit. 'S General Public MPE vs Distance 120 100 LLJ 80 c. a, 60 c n� 40 20 0 0 54 100 150 200 250 300 350 400 450 500 Distance (ft) - VZW MPE Contribution -FCC MPF limit 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell 9 PA • 19422 c,rcet 4. Appendix A: Reference Information FCC Rules & Regulations All information used in this report was analyzed as a percentage of the MPE limits as detailed in 47 CFR 1.1310. The calculated power density at each sample point divided by the limit at each calculated frequency provides a result in % MPE. Summing the calculated % MPE from all contributors provides accumulative % MPE at a particular sample point. Wireless carriers use different frequency bands with varying MPE limits; therefore, it is useful to report results in terms of % MPE as opposed to power density. All results were compared to the FCC radio frequency exposure rules as detailed in 47 CFR § 1.1307(b) to determine compliance with the MPE limits for General Population/Uncontrolled environments as defined below: 1 IM %1HtN51111 tL1U11n1 lUl- r Apul UCc Lllllll, Occupational — Applies to situations in which persons are "exposed as a consequence of their emplo}�inent" and are aware of the potential for exposure and can exet•cise control over their exposure". Environment Classification General Population — Applies to situations in which persons are "exposed as a consequence of their employment may not be »lade f d1j) aii,,are of the potential for exposure or cannot exercise control over their exposure". Generally speaking, those without significant and documented RF Safety & Awareness training would be in the General Population classification. Controlled — Applies to environments that are restricted Uncontrolled — Applies to environments that are or "controlled" in order to prevent access from members unrestricted or "uncontrolled" that allow access from of the General Population classification. members of the General Population classification. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 c.�,,rcet FCC Limits for Maximum Permissible Exposure (MPE) Plane -wave Equivalent Power Density 1000 N 100 V E 10 L 3 o: 0.1 0.01 — Occupational — —General Public 0 1 10 100 1, 000 101000 Frequency (MHz) The MPE limits defined in 47 CFR 5 1. 13 10 and utilized in this analysis are outlined in the table and diagram below: Lhn tS of Occu atlonallControlled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Rance L14(MfIZ) Strength Strength (S) E 2, II 2'Ors (E) (V/m) (H) (A/m) (MA'S,/cm2) (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f2)* 6 30-300 61.4 0.163 1.0 6 300-1500 -- -- f/300 6 1500-100,000 -- -- 5 6 L11111tS o)' General Po ulat1onlUncontrolled E.� OSure Fi'e uency Electric Field Magnetic Field Power Density Avera ing Time Dance Strength Strength (S) JE 12, 1-12, or S (11l11z) (E) (V/m) (11) (A/m) (MN.N,/cm2) (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/P-)* 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/1500 30 1500-100,000 -- -- 1.0 30 f = f'egueticy in MHO * = Plane -wave equivalent power densi 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell 9 PA • 19422 u City t, Vah A+e tie A+• T Jo pi ''" l •sxa�a• � s sw. O � r L_�'1�e b gat Ui+' i� cx��ig M�f�hftllPt © carle tent ^y t:M t. r, •� Tei,r�,d Yr sptrnq �I �� -�_ .: S11, A•t6 Congiess P,vt 0 � c i :T � bnry R4�L•h,. ri_ir]!, Ir') S3'i':�K�:: +ir a ••ry a Mhryr St t; Jo �`?lkYry In uh I. A Ave' / t1c VICINITY MAP DIRECTIONS DIRECTIONS TO SITE: FROM NORTH GREENBUSH SWITCH FACILITY, TURN LEFT ONTO US-4 N. TURN LEFT ONTO MORRISON AVE. TURN LEFT ONTO HIGH ST. TAKE I-787 N. TAKE EXIT 9W TO MERGE ONTO NY-7 W. TAKE EXIT ONTO 1-87 N. TAKE EXIT 14 FOR NY-9P/UNION AVE. TURN RIGHT ONTO NELSON AVE. TURN LEFT ONTO PHILA ST. TURN LEFT ONTO COURT ST. SITE WILL BE ON THE LEFT. CELLCO PARTNERSHIP, d/b/a SPRING STREET DELI FUZE ID#: 16085149 MDG#: 5000958473 UTILITY POLE #: NG 7-1 SITE ADDRESS: ADJ TO 72 COURT ST SARATOGA SPRINGS, NY 12866 MUNICIPALITY: CITY OF SARATOGA SPRINGS COUNTY: SARATOGA TAX MAP NUMBER: PUBLIC R.O.W. STRUCTURE COORDINATES: 43.079106' -73.778802' GROUND ELEVATION: 313'f AMSL POLE OWNER: NATIONAL GRID POLE #: NG 7-1 APPLICANT: VERIZON WIRELESS 175 CALKINS ROAD ROCHESTER, NY 14623 CONTACT PERSON: MAGGIE BAUGHMAN CONTACT PHONE: (585) 321-5390 1PROJECT SUMMARY I PROJECT DESCRIPTION THE PROPOSED WORK CONSISTS OF: • REMOVE EXISTING WOODEN UTILITY POLE. REPLACE WITH A PROPOSED 45' (CLASS 1) 'WOODEN UTILITY POLE AND RELOCATE ALL APPURTENANCES TO THE PROPOSED POLE. • INSTALL (1) CELLULAR ANTENNA & ASSOCIATED EQUIPMENT ON PROPOSED POLE. • INSTALL ELECTRICAL, TELCO AND CABLE ROUTING AS NECESSARY. SHT. NO. DESCRIPTION REV NO REVISION DATE T-1 TITLE SHEET 1 6/11/26 GN-1 GENERAL NOTES 1 6/11/26 C-1 SITE PLAN & EQUIPMENT PLAN 1 6/11/26 C-2A MAKE READY SCOPE OF WORK 1 6/11/26 C-2B POLE ELEVATION & DETAIL 1 6/11/26 C-3 POLE MOUNT DETAILS 1 6/11/26 E-1 ELECTRICAL & GROUNDING DIAGRAMS & DETAILS 1 6/11/26 SHEET INDEX THIS SET OF PLANS SHALL NOT BE UTILIZED AS CONSTRUCTION DOCUMENTS UNTIL ALL ITEMS OF CONCERN HAVE BEEN ADDRESSED AND EACH OF THE DRAWINGS HAS BEEN REVISED AND ISSUED "FOR CONSTRUCTION". SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE. 3, UNDERBUILD NG 9-713 AND ATTACH 36'. 4. RE -ATTACH TPX AT 29'. 5. REPLACE SEC BRACKETS (NG 10-101 FIG 5). 6. INSTALL SINGLE POLE GROUND AND ROD PER (13-111) FOR ANTENNA EQUIPMENT AND BOND NEUTRAL. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK - CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS, LICENSE APPLICATION #SPRING ST DELI / 500095847 WORK REQUEST #31254119 UTILITY PROVIDERS ELECTRIC PROVIDER: NATIONAL GRID ESR #: TBD ACCOUNT #: TBD FEEDER#: TBD PLANNER: TBD PHONE: TBD FIBER: VER!,ZON Before You Dig, Drill Or Blast! i Dig Safely. New York UNDERGROUND FACILITIES PROTECTA/E ORGANIZATION CALL US TOLL FREE 1-800-962-7962 NY industrial code rule 753 requires no less than two working days moue, but not more than ten nays notice. DO NOT SCALE DRAWINGS THESE DRAWINGS ARE FORMATTED FOR 22"x34" FULL SIZE AND 11"07" HALF SIZE. OTHER SIZED VERSIONS ARE NOT PRINTED TO THE SCALE SHOWN, CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. verizon I175 CALKINS ROAD I ROCHESTER. NY 14623 Tectoni P*c RACTICIU. SOLUTIONS. RXCWrn0K&L iRRVICI. Teclook Etgbmw*q Cmv v*N Oeobplels t land 'Swwpn . O.P.C. Frvfect eanfeet Into 36 British Amerl=n Blva. Phone: (518) 783-16M Suite 101 (800) 829-6531 Lolharn. NY 12110 www.tectonicenginaering.com NO NUMBER DRAWN BY REVIEWED BY 12861.035A I TRR MP Kim HATE' lest IC 0 5/13/26 FOR REGULATORY 1 6/11/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMiLiF Of THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 ? ORIGINAL SIZE IN INCHES (11 x17 FORMAT) SITE INFORMATION SPRING STREET DELI FUZE ID#: 16085149 MDG#: 5000958473 SITE ADDRESS UTILITY POLE NG 7— 1 ADJ TO 72 COURT ST CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 TITLE SHEET SHEET NUMBER Twl JELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE LOCAL CODES. 2. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED. 3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 4. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 5. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 6. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1 /2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA. 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE RATING, POWER OR AAPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S). 8. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED. 9. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, STRANDED COPPER CABLE RATED FOR 90-C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (#6 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THAN-2 GREEN INSULATION, STRANDED COPPER CABLE RATED FOR 90-C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI -CONDUCTOR, TYPE USE-2 CABLE (##14 AWG OR LARGER), 600 V, QIL RESISTANT RHW-2 OR XHHW-2, STRANDED COPPER CABLE RATED FOR 90-C (WET AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED. 12. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOM.AS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 90'C. 13. ELECTRICAL METALLIC TUBING (EMT) OR RIGID METALLIC CONDUIT (RMC) SHALL BE USED FOR EXPOSED OR CONCEALED LOCATIONS. 14. ALL OUTDOOR EXPOSED CONDUIT SHALL BE PVC SCHEDULE 80 AND SHALL BE SUPPORTED ADEQUATELY. 15. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED, LFMC SHALL CONFORM TO NEC ARTICLE 350. 16. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 17. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. 18. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 3R (OR BETTER) OUTDOORS. 19, IF REQUIRED, CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS, SERVICE ROUTING, AND METER SOCKET TYPE WITH LOCAL POWER COMPANY. 20. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS, 21. CONTRACTOR SHALL LABEL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.16 AND 110.24. 22. CONTRACTOR SHALL VERIFY THAT THE MAIN BONDING JUMPER AND GROUNDING ELECTRODE I CONDUCTOR IS INSTALLED PROPERLY AT SERVICE ENTRANCE. 23. WHERE ELECTRICAL POWER IS TO BE SUB -FED FROM AN EXISTING DISTRIBUTION SYSTEM, THE FOLLOWING SHALL APPLY: A. CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND PER N.E.C. ARTICLE 220. B. CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE 220. C. EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS EQUIPMENT SUPPLYING IT. D. PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE LOCATED IN EXISTING PANEL. ANTENNA MOUNTING NOTES 1. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO ANSI/TIA-222-H-2017 "STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES, ANTENNAS AND SMALL WIND TURBINE SUPPORT STRUCTURES". THE BUILDING CODE OF NEW YORK STATE, AND ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL CODES. 2. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 "ZINC (HOT -DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS OTHERWISE NOTED. 3. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL. BE GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC -COATING (HOT -DIP) ON IRON AND STEEL HARDWARE", UNLESS OTHERWISE NOTED. 4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN ACCORDANCE WITH ASTM A780 "REPAIR OF DAMAGED AND UNCOATED AREAS OF HOT -DIP GALVANIZED COATINGS", USING COLD GALVANIZING COMPOUND AS MANUFACTURED BY ZINGA-USA OR ZINC KOTE, OR ENGINEER APPROVED EQUAL WITH A MINIMUM METALLIC ZINC CONTENT OF 95% BY WEIGHT IN DRY FILM. DRY FINISHED COATING THICKNESS SHALL BE 3 MILS MINIMUM. 5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE NUTS AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 6. DESIGN OF THE ANTENNA MOUNTING BRACKETS, SUPPORTS, AND ALL COMPONENTS THEREOF AND ATTACHMENT THERETO SHALL BE THE RESPONSIBILITY OF THE MANUFACTURER. MANUFACTURER SHALL PROVIDE THE OWNER DRAWINGS DETAILING ALL COMPONENTS OF THE ASSEMBLY, INCLUDING CONNECTIONS, DESIGN LOADS, AND ALL OTHER PERTINENT DATA. MANUFACTURER SHALL ALSO PROVIDE THE OWNER WITH A STATEMENT OF COMPLIANCE, INDICATING THAT THE ANTENNA SUPPORTS HAVE BEEN DESIGNED IN ACCORDANCE WITH ANSI/11A-222-H STANDARDS. ALL SUBMISSIONS SHALL BEAR THE SIGNATURE AND SEAL OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK. STRUCTURAL NOTE 1. THE VERIFICATION OF STRUCTURAL ADEQUACY AND DESIGN OF THE ATTACHMENTS MUST BE PERFORMED, PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK. 2. REFER TO STRUCTURAL ANALYSIS REPORT PREPARED BY XXXXXXXXXXX DATED XX/XX/XX. GROUNDING NOTES GROUND TESTING AFTER CONSTRUCTION: 1. AFTER COMPLETION OF CONSTRUCTION OF THE CELL SITE GROUND SYSTEM, A POST INSTALLATION GROUND TEST SHALL BE PERFORMED BY THE CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE GROUND RESISTANCE FOR ALL SITES AFTER INSTALLATION OF THE EARTH GROUND SYSTEM. A PRELIMINARY EARTH RESISTIVITY TEST (3 POLE TEST OR CLAMP -ON -METER) SHALL BE PERFORMED PRIOR TO BACK FILLING ALL TRENCHES AS SPECIFIED IN VERIZON NETWORK STANDARDS (NSTD46) AND THE NATIONAL ELECTRIC CODE. 2. APPROVED MEASUREMENT METHODS FOR POST INSTALLATION GROUND TESTING SHALL BE ONE OF THE FOLLOWING METHODS: A. FALL OF POTENTIAL METHOD - 3 POINT B. CLAMP -ON RESISTANCE TEST C. TOWER AND EXTERNAL CONDUCTOR TEST 3. A GROUNDING (RESISTANCE TEST REPORT SHALL BE PREPARED UPON COMPLETION OF THE TESTING. THE TEST REPORT SHALL SHOW THE RESISTANCE IN OHMS AT 407a, 52%, 627., 72% AND 82% POINTS IN 10% INTERVALS. RESISTANCE IS TO BE RECORDED AT EACH INTERVAL FOR EACH POINT FOR FOUR (4) DIFFERENT DIRECTIONS UNTIL THERE IS A PLATEAU SEEN AT THE 62% POINT. TESTING SHOULD BE COMPLETED IN A MINIMUM OF TWO (2) DIFFERENT DIRECTIONS AT 90 DEGREES APART. RECORD THE AVERAGE OR MEAN AS THE RESISTANCE OF THE SITE AND ENTER THIS ON THE POST RESISTANCE DATA CHART. 4. PROVIDE THE POST INSTALLATION - GROUND RESISTANCE TEST REPORT TO THE REGIONAL PROJECT ENGINEER ACCOMPANIED BY THE POST RESISTANCE DATE CHART. 5. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. ALL BENDS SHALL BE MADE WITH 12" RADIUS OR LARGER. 6. APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 7. GROUNDING TEST SHALL BE TAKEN BEFORE A/C POWER, NEUTRAL/GROUND BOND IS CONNECTED. 8. ANTI -OXIDATION CONDUCTIVE COMPOUNDS ARE REQUIRED ON ALL GROUND CONNECTIONS. NO OX-ID (COSMOLINE GREASE BASED COMPOUND) SHALL BE USED FOR COPPER TO COPPER CONNECTIONS. ZINC BASED COMPOUND (GREY COLORED) OR APPROVED EQUAL SHALL BE USED FOR COPPER TO STEEL CONNECTIONS. 9. ALL LUG CONNECTIONS & THEIR MATING SURFACES SHALL BE CLEANED AND COATED WITH THE APPROPRIATE ANTI -OXIDIZING CONDUCTIVE COMPOUND. IF A LUG CONNECTION IS TO BE SECURED DIRECTLY TO A PAINTED SURFACE, THE PAINT SHALL BE REMOVED TO REVEAL BARE METAL AROUND THE AREA OF THE CONNECTION AND COATED WITH AN APPROPRIATE ANTI -OXIDATION CONDUCTIVE. COMPOUNDS. GENERAL NOTES 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK STATE BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND ORDINANCES. 2. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND MAKE PROVISIONS AS TO THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 3. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS OTHERWISE NOTED. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 4. DIMENSIONS SHOWN ARE TO FINISH SURFACES, UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE CARRIER'S AUTHORIZED REPRESENTATIVE OR THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 5. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 6. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ALL PRODUCTS OR ITEMS NOTED AS "EXISTING" WHICH ARE NOT FOUND TO BE IN THE FIELD. 8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST CONSTRUCTION SKILLS AND ATTENTION, CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. 9. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, AND ADJACENT AREAS, THAT ARE LIKELY TO BE AFFECTED BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS. 11. CONTRACTOR SHALL COORDINATE HIS WORK AND SCHEDULE HIS ACTIVITIES AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS OF THE OWNER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS 'WORK WITH THE WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS AND ANY OTHER PORTIONS OF THE WORK. 13. CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT THE OWNER AND CARRIER. 14. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 15. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT, IMPROVEMENTS, PIPING, ANTENNA AND ANTENNA CABLES. REPAIR ANY DAMAGE THAT OCCURS DURING CONSTRUCTION. 16. REPAIR ALL EXISTING SURFACES DAMAGED DURING CONSTRUCTION SUCH THAT THEY MATCH AND BLEND WITH ADJACENT SURFACES. 17. KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL COMPLETION OF CONSTRUCTION. 18. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND ERECTION OF ANY MATERIAL. ANY UNUSUAL CONDITIONS SHALL BE REPORTED TO THE ATTENTION OF THE ENGINEER. 19. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND INSPECTIONS AND PAY ALL REQUIRED FEES. 20. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A/10-BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDOUT AREA DURING CONSTRUCTION. 21. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS AND OTHER DOCUMENTATION SHALL BE TURNED OVER TO CARRIER AT COMPLETION OF CONSTRUCTION. 22. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF ACCEPTANCE BY CARRIER. ANY WORK, MATERIALS, OR EQUIPMENT FOUND TO BE DEFECTIVE DURING THAT PERIOD SHALL BE CORRECTED IMMEDIATELY UPON WRITTEN NOTIFICATION AT NO ADDITIONAL COST TO CARRIER. 23. RIGGING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH STATE AND FEDERAL SAFETY REGULATIONS (OSHA). ENGINEER, CARRIER AND THE OWNER SHALL BE HELD HARMLESS IN THE EVENT THE CONTRACTOR DOES NOT FOLLOW SUCH SAFETY REGULATIONS. 24. CONTRACTOR SHALL PROVIDE ACCESS TO THE SITE AND ASSIST THE RADIO EQUIPMENT VENDOR AND THE ANTENNA INSTALLATION CONTRACTOR AS THEY MAY REQUIRE. verizon I 175 CALKINS ROAD I ROCHESTER, NY 14623 1=1 Tectonic ,RwmCAL SOt tnlotIL IlocCWl"1oi4ALsorvlca. TOCIAIM E+gkWW%g COnNAVlta, 09ob*W 4 land SAwom D.P.C. Project contact info 36 Rr:tieh Amerlcon Slvo. Phone. (518) 783-1"0 suite 101 (800) 829-8531 Latham. NY 12110 www.teatonicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12861.035A I TRR MP ►In MAI= loci IV 0 5/13/26 FOR REGULATORY 1 6/11/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 0 1 ORIGINAL SIZE IN INCHES (11x17 FORMAT) SITE INFORMATION SPRING STREET DELI FUZE ID#: 16085149 M DG#: 5000958473 SfTE ADDRESS UTILITY POLE# NG 7-1 ADJ TO 72 COURT ST CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE GENERAL NOTES SHEET NUMBER NORTH ORIENTATION 1 I. ��GF'H ORIENTATIO:'•� ESTABLISHED BY COMPASS OBSERVATION. 1 1 /� - - �, ,-�`}ems � •�1 8 a • EXISTING OVERHEAD / WIRE (TYP) , C - f ••�, L - r� ! pyw I1 C) I u'"` / At - PROPOSED VERIZON WIRELESS EQUIPMENT ON I t 9 PROPOSED UTILITY POLE. NEW POLE TO 4 �►° j' REPLACE EXISTING UTILITY POLE #NG 7-1 EXISTING UTILITY / POLE (TYP) ``- ` r L / I s r • /! I . , 1 pyw r ', yw I li 1 / t • 7 � ' _ , �•x L r M .00 4 � r1 I NOTE: SITE INFORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING CONSULTANTS, GEOLOGISTS & LAND SURVEYORS D.P.C., ON 11 /19/25. SITE PLAN - S�A•L�: 1' = 80' (11x17 SIZE) 1- = 40' (22x34 SIZE) EDGE OF EXISTING CURB PROPOSED 1-1 /2" CONDUIT (FROM SECONDARY TO METER) r� l r PROPOSED METER PROPOSED #2 VERTICAL GROUND 1 �3• ---- PROPOSED 1-1 /4 PVC RISER FOR AC CIRCUITS TO SHROUD 1 verizon 175 CALKINS RCAD I ROCHESTER, NY 14623 ectonic PRACTICAL SOLUTIONS. RX00, ONALSMICA. Tectoere Engl mwb.p Caesultonts, Cwobgis s t Land SurvgoM D.Q C. 36 E'r-0ah Amofl.Dn 81va. Phone: (518) 783-1G30 sv_e 10'. (800) 829—E531 Latham. NY 12110 wY ,tectonicengineering.corr WO NUMBER DRAWN BY REVIEWED BY 12861.035A TRR j I MP PROPOSED 100A LOAD CENTER _j N0. DATE ISSUE 0 5/13/26 FOR REGULATORY r , 1 6/11/26 ACDED PAINT NOTE !` -- PROPOSED REPLACEMENT f UTILITY POLE ` EXISTING GRASS AREA / - EXISTING UTILITY POLE TO r1r BE REMOVED & REPLACED EXISTING CONCRETE SIDEWALK J�7/ EQUIPMENT PLAN C-1 SCALE: 3/4" = 1'-0" (i 1 x17 SIZE) 1 /2" = 1'-0" (22x34 SIZE) Ir- PROPOSED �" "T`'' ` ^"`'`'" FIBER ENCL TO EXTE _ --�3- PROPOSED 4" U-GUARD FOR N COAX CABLES TO ANTENNA 1 PROPOSED #2-, 11ti VERTICAL GROUND 1 PROPOSED VERIZON WIRELESS --- 1" FIBER CONDUIT PROPOSED 1-1/2" CONDUIT -` (FROM SECONDARY TO METER) Lj PROPOSED REPLACEMENT UTILITY POLE PROPOSED VERIZON WIRELESS_' EQUIPMENT SHROUD WITH PROPOSED RRH AND ASSOCIATED EQUIPMENT (SEE DETAIL 5/C-3) SHROUD PLAN VIEW S ;AL=: 3/4" 1'-0" (i 1 x17 SIZE) 1-1/2" = 1'-D" (22x34 SIZE' UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLA'ION OF SECTION 7209 SUED -VISION 2 OF THE NFW YORK STATE EDUCAs1ON U14. COPIES OF THIS DOCUJEN' WIT>-IOUT A FACSIMILE 0; THE SiGK,iTLF.E A',ID AN ..^.R!GINA'_ EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFLSS:ONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) G 1 ORIGINAL SIZE IN INCHES (11x17 FORMAT) SITE INFORMATION SPRING STREET DELI FUZE ID#: 16085149 MDG#: 5000958473 SITE ADDRESS UTILITY POLE# NG 7-1 ADJ TO 72 COURT ST t CITY OF SARATOGA SPRINGS ` SARATOGA COUNTY NY 12866 SHEET TITLE SITE PLAN & EQUIPMENT PLAN SHEET NUMBER C�l SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL P-R MUTCD REQUIREt11ENTS. 2. ELCO TO SET NEW 45' LONG CLASS 1 UTILITY POLE. BURY DEPTH TO BE 6.5'. REMOVE EXISTING 40' LONG POLE. 3. UND=RBUILD NG 9-713 AND ATTACH 36'. 4. RE -ATTACH TPX AT 29'. I 5. REPLACE SEC BRACKETS (NG 1C-101 FIG 5). 6. INSTnLL SINGLE POLE ROUND AND ROD PER (13-111) FOR ANTENNA EQUIPMENT AND BOND NEUTRAL. NATIONAL GRID .APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. L'CEhJSE APPLI -A - CN #SPR [v3 ST DELI / 500095847 'WORK REQUEST , 31254119 TOP OF EXISTING U TILITY POLE 32.0'± AGL — EXISTING PRIMARY 31.5'± AGL EXISTING SECONDARY 23.0'± AGL EXISTING COMM LINE _ 18.1'± AGL \, 1 EXISTING GUY 't'dl =;E 17.3' ± A. G L EXISTING COMM, LINE 17.1'± AGL - EXISTING POLE PHOTO SCALE: NTH — I T IN EXISTING PRIMARY ELECTRIC LINE TO BE RELOCATED PER NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) I EXISTING SECONDARY ELECTRIC I LINE TO BE RELOCATED PER eI! NATIONAL GRID REQUIREMENTS (SEE 3/C-2A) EXISTING COMMUNICATION i' LINE TO BE RELOCATED (BY OTHERS) (TYP) EXISTING GUY WIRE TO BE RELOCATED (BY OTHERS) EXISTING TELCO BOX TO BE RELOCATED (BY OTHERS) -= EXISTING UTILITY POLE #NO 7-1 TO BE REMOVED & REPLACED EX.STING GRADE S-RE-,T S DE EXISTING UTILITY POLE ELEVATION -2k SCALE: 3/16" = 1'-O" (1107 SIZE) 3/8" - V-0" (22x34 SIZE) TOP OF PROPOSED UTILITY POLE 38.5'± AGL Ljlk RELOCATED 36.0'± AGL r RELOCATED 29.0'± AGL RELOCATED 20.0'f AGL __ RELOCATED 1 19.0'± AGL RELOCATED 18.5'± AGL JNDERBUILD NG 9-713 kND ATTACH 36' ATTACH TPX AT 29'. REPLACE BRACKETS (NG 10-101 FIG 5) TING COMM LINE REATTACHMENTS 3E DONE BY OTHERS (TYP) LOCATED TELCO BOX lY OTHERS) POSED 45' LONG CLASS 1 _ACEMENT UTILITY POLE RRY DEPTH 6.5') EXISTING GRADE STREET S DE PROPOSED UTILITY POLE ELEVATION SCALE: 3/16" = 1'-G" (11xi7 SIZE) 3/5" = 1'-O" (22x34 SIZE) verizon 175 CALKINS ROAD I ROCHESTER, NY 14623 ectonic PL Ttclarie UV wln0 Cw*AwTtt, Gsdogikt & LwW Sw-ptf. Q.P.C. Project Cantnet Into 36 Pr;tinh Am�rlcon 91vC. Phone: {518) 783-1G30 Sj:1c 101 (900) 829-EE31 Loth=rr, M' 12110 www.teclohiccngmeerna.com NO NUMBER DRAWN BY REVIEWED BY 12861.035A TRR MP Kin nATV lccllr 0 5/13/2%6 FOR REGU:ATORY 1 6/' 1 /26 ADDED PAINT NOTE OwAA S /4 929 14 �rp�FSSI�Y'� UNAUTHORIZED ALTERAION OR ADDITIONS TO A PLAN BEARING THE SEAL 0= A UC=LASED ENGINEER OR LAND =_LRVEYOR IS A =LA710N OF SECTION 7209 SUBDIVISION 2 OF THE NFN YORK STATE EDUCATION LAW. COPIES OF THIS DOCUVEN7 1,147-TOUT A FACSIMILE OF THE S'Gt,ATLRE AND AN ORiGINA_ EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE CR RED INK OF THE PROFESSiONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIISINAL SIZE IN INCHES (22x34 Fn-RI,, AT) 0 ORIGINAL SIZE IN INCHES (11 x17 FORMAT) SITE INFORMATION SPRING STREET DELI FUZE ID#: 16085149 MDG#: 5000958473 UTILITY POLE# NG 7-1 ADJ TO 72 COURT ST CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE MAKE READY SCOPE OF WORK SHEET NUMBER Cs2A PROPOSED 4G ANTENNA (SEE DETAIL 1 /C-3) PROPOSED POLE TOP ANTENNA MOUNT (SEE DETAIL 1/C-3) INSTALL RF "CAUTION" SIGNAGE 2'f BELOW PROPOSED ANTENNA (SEE DETAIL 4/C-3) PROPOSED WEATHERHEAD FOR POWER- (CARLON P/N: E998H-CAR OR APPROVED EQUAL) PROPOSED COAX CABLES TO ANTENNAS IN 4" MAX U-GUARD EXISTING TELCO BOX (BY OTHERS) PROPOSED MOPT TERMINAL (BY OTHERS) PROPOSED LC/UPC BIDI RUGGEDIZED FIBER JUMPER FROM THE PROPOSED MOPT TERMINAL TO PROPOSED FUJITSU PASSIl/`E FIBER ENCLOSURE WITHIN 1" CONDUIT PROPOSED VERIZON WIRELESS EQUIPMENT SHROUD WITH PROPOSED RRH & ASSOCIATED EQUIPMENT (COMMSCOPE PN: SSC-760249586X1 X ' OR EQUAL) (SEE DETAIL 5/C-3) CZB PROPOSED 1-1 /4" PVC RISER FOR - AC CIRCUITS TO SHROUD PROPOSED EATON BRP12B10OR LOAD CENTER OR APPROVED EQUAL (SECURE TO POLE USING UNISTRUT OR APPROVED MANUFACTURER RECOMMENDED HARDWARE) PROPOSED RF "INFORMATION" SIGNAGE (SEE DETAIL 4/C-3) PROPOSED METER MILBANK P/N: U2048-RL OR APPROVED EQUAL (SECURE TO POLE USING ERICKSON SERIES PBAL MOUNTING BRACKET OR ELECTRIC COMPANY APPROVED EQUAL) PROPOSED HIGH IMPACT - PVC CABLE COVER (BLACK) _ TOP OF PROPOSED ANTENNA rik 42.3t AGL PROPOSED ANTENNA 41.3't AGL TOP OF EXISTING UTILITY POLE 38. ��'t AGL EXISTNG PR Iv1ARY 3n.0'f AGL EXISTING_ SECONDARY 29.0't AGL - PROPOSED 1-1/2" PVC RISER FOR POWER - PROPOSED FIBER LINE (SOURCE TO BE DETERMINED) (BY OTHERS) PROPOSED FIBER 21.0't AGL ' EXISTING COMMUNICATION 2n.0'± AGL - - EXISTING GUY ',h'IRE 19.0'-- AGL EXISTING COMMUN ICAT10\1 _ 18.3'± AAGL 3 _ BOTTOM OF PROPOSED MOPT TERMINAL --- C-1 - -- -- _ 16.3'f AGL ___- -PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE MOUNTED TO EXTERIOR OF SHROUD BOTTOM OF -PROPOSED EQUIPMENT_- __ ------------------------------------ - - - 12.0'f AGL (MINIMUM) ! BOTTOM OF PROPOSED LOAD CENTER 10.0'f AGL (MINIMUM) BOTTOM OF PROPOSED METER -} ------- ----- -- - - - - - --- _- -- 8.0'f AGL (MINIMUM) I BOTTOM OF PROPOSED RF SIGNAGE 8.0'f AGL (MINIMUM) `- EXISTING J'! 1ITY POLE EXISTING GRADE j STREET SIDE UTILITY POLE ELEVATION ` `:CALF: 3/16" = 1'-01. (1107 SIZE) 3/8" = 1'-0" (22x34 SIZE) EX,IST13NG GRADE rik 0.0'+ AGL EXISTING GUY WIRE PROPOSED VERIZON WIRELESS - 4" U-GUARD (CABLES FROM RRH TO ANTENNA) PAINTING NOTE: ALL PROPOSED EQUIPMENT SHALL BE PAINTED BROWN NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. f I --- PROPOSED 1-1/2" CONDUIT (FROM SECONDARY TO METER) (ON OPPOSITE SIDE OF POLE) PROPOSED FIBER LINE (SOURCE TO BE DETERMINED) (BY OTHERS) EXISTING COMM LINE (TYP) / PROPOSED MOPT TERMINAL (BY OTHERS) PROPOSED LC/UPC BIDI RUGGEDIZED FIBER JUMPER FROM THE PROPOSED MOPT TERMINAL TO PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE - PROPOSED VERIZON WIRELESS EQUIPMENT SHROUD (COMMSCOPE PN: SSC-760249586Xi X OR EQUAL) (SEE DETAIL 5/C-3) PROPOSED RUGGEDIZED FIBER JUMPERS TO RRHs AND MMUs IN THE SHROUD (TYP OF 2) PROPOSED EATON BRP12610OR LOAD CENTER OR APPROVED EQUAL --_---PROPOSED 1-1/2" LIQUIDTIGHT (METER TO LOAD CENTER) PROPOSED METER MILBANK P/N: L _�- T-- U2048-RL OR APPROVED EQUAL (SECURE --- -- TO POLE USING ERICSSON SERIES PBAL MOUNTING BRACKET OR APPROVED EQUAL) EXISTING UTILITY POLE ELEVATION DETAIL `y SCALE: 2= 1'-0" (11x17 SIZE) —0" (22x3. S!ZE) verizon j 175 CALKINS ROAD I !I ROC:F=STER. NY 14623 Tecton'i*c ►RACMAL SOSERVICE. TocLorre ErglnwrtV Convt*m it 600hqWb i Land &owmi , D.M Pmj.ct Cc�.to_t Info 36 er,tiRh Amerlcon Blvd- Phorer (518) 783-1633 Si. a 10' (900) 829-6531 Lat-inm. NY 12110 nww.te--tvricengineer;ng.corr WO NUMBER DRAWN BY REVIEWED BY 12861.035A TRR I�1P A1r1 MA= ICCI IC j 5/ 13/26 FOR REGULATORY 1 6/'.1/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND URVEYOR IS A VIOLATION OF SECTION 7209 SLSDTVISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPES OF THIS DOCUMENT WITHOUT A FACSIMILE O: THE SIGNATUF.E AND AN ' RIGI'VVL EME1 OSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINCER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VAUD COPIES. 0 1 ORIGINAL SIZE IN INCIHES (22x34 FORIv AT) 0 1 ORIGINAL SIZE IN INCHES (11x17 FCRMAT'` SITE INFORMATION SPRING STREET DELI FUZE ID#: 16085149 MDG#: 5000958473 SITE ADDRESS UTILITY POLE# NG 7-1 ADJ TO 72 COURT ST CITY OF SARATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE POLE ELEVATION & DETAIL SHEET NUMBER Ca�2B ANTENNA (COMMSCOPE P/N: V4S4-36OS-BF2) ANTENNA MOUNT SLEEVE (GIMBAL) (CONCEALFAB P/N: 900070) - POLE MOUNT BRACKET (CONCEALFAB P/N: 007951 OR APPROVED EQUAL) UTILITY POLE 0 TO BE VERIFIED IN FIELD 1 POLE —TOP ANTENNA MOUNTING - CA E: .T_ A CAUTION A Transmitting Antenna(s) Radio frequency fields beyond this point MAY EXCEED the FCC Occupational exposure limit. ®Obey all posted signs and site guidelines. Call Verizon at 1-800-264-6620 PRIOR to working beyond this point. Site ID/ PSLC: verizon ' ACTLIVE COM1itUNICA7 ON EOUft" t u*tY1IY Airl#OACd 1=70CE S FT 1+01R2ONTAL AMD FT VERr1GL 113%" 001111 A ME111" Wr "Ulm O=o% 4CT StMT04 OR CMl VEMI Pi WIR[LESS rat PM it sm4nvvrAl(wWWI41ERAPr(wACI-hr Ab.n1&A*W*W __IT ►r3fttO TALAAP FT WRTKM P14"K CALL VER2M WiRELE88 AT1-M-4"M PRIOR TO oPERAM4 DOC CT avl MC4 $mdrt--:,fir or o. uc,!oda►rooc _ verizon,/ NOTE: 1. CONTRACTOR TO FURNISH AND INSTALL PHENOLIC LABEL APPLIED 70 LOAD CENTER. 2. ATTACH RF "CAUTION" AND "INFORMATION" SIGNAGE TO FACE OF UTILITY POLE USING 1" WOOD SCREWS. 3. RF SIGNS ARE APPROXIMATELY 6"x7.5" IN SIZE. PROPOSED SIGNAGE -•CALL: NT.. -'OLE MOUNTING BRACKET -•� (ERICKSON P/N: PBAL-12 OR APPROVED EQUAL) (TYP OF 2) p D ` e : 0 �3 e ---1/4"x1" WOOD SCREW (TYP OF 4/13RACKET) - S.S. 1/4"-20x3/4" CARRIAGE BOLT, FLAT WASHER, & NYLON LOCK NUT (INCLUDED WITH BRACKET) PROPOSED METER SOCKET, MILBANK P/N/ U2048-RL (OR APPROVED EQUAL CONFORMING TO UTILITY COMPANY STANDARDS) (:,�)METER MOUNTING DETAIL C 3 SCALE: N Metre Cell Solutions COMMSCQY'E SSC-760249586X1X MV2 Micro Radio Concealment Enclosure Universal Single Part Number Radio Enclosure IntroduC'tion One pole mounted Radio Enclomm br aill your radio -r corttotaroons under a sinWe part number Highly Con5gurabie - sigwo(ts vamnp conftguraborts with a universal moto-Ang solution • Aestheticrelty our:ed kiont a A•r :-epta Radios for. >t EAcssm rachos SSC-760249586E1X Nokia radios SSC-760249588N 1 X SamawV rsdin SSC-7602495WSIX Aplplicatean Th= Jic concealment enclo we is designed to cone" small c eill r Kin and be mounted lo ext Ong metal, aoncrnte. and wood pole sinietu(res as well as pole replacernerlts wilw(e Taw-virgwl impact is ,r desired. - • Unique. universal intemal mounting system • Can be kltted with Recbfiers. ComnTSoope - d►plexerS and jumpers System Dimensioning & Configuration t 1 Widlt ' F3ytfh r Vokrre 48 in. 11219 2 mrn' t 24 in x`5L14.6 mn1) 126 in iW 4 rrw 1 17.3 c„ It IDNbs (43kg) wilh no rack" eoupnllrt,`stalled S_ I1i:-)ip i Appea 4751be (216kg) GAV kiederr (max) 'y.--I$ wanes on conf;pration L4r1 Max. Aixoptabds Pots 00 2.5rd-8-5 in 00 by ciarr000 (Larger one► poke by W" n4) :nth k,clrrde7l.4nurtely Tot) uF to 1Jn 1D Wow Pntewm sud+xa 5F 41re ded r*�s'c t1r_•�x bc+fN,g UV-recutax powde►coat V3ri 2-.1d; U*r dpkm e.ailaL40 Fr> in '1- for Light Gray. -2' for Green -X for 84N*- -4' for Bran -6 (t'+r Falfts BrToom 'F•' Federal Park Brown. *7 for Metals c Siva- 'W for Mate 9add' (i) ;'Trade Size Krvrkwu F_vver,Fdrer input Cundud Bcr- (2) 2 Trade See KnackouG Top: (2; 2' Trade Sue Knockr..,ts MC-SP-REMI- 21-003 -04 NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. UTILITY POLE PROPOS=C EATON BRP12E" ^^n ELECTRIC PANEL OR APPROVED E PROPOSED 1 /4"x20 3/4" LONG BOLT (TYP OF 3) PROPOSED P1000T - UNISTRUT 6" LONG (TYP OF 2) PROPOSED 1 C.'HANNEL NUT (TYF PROPOSE[ LA 3 LOAD CENTER MOUNTING DETAIL SCALE: 4- - 1'--0" (11x17 SIZE) = V-0" (22x34 SIZE) Metro Cell Solutions COMMS0,- PE Ericaeon Configurarwns •(2)RRU11;RRU32t2?1244TS4425:447F,5t2)PSU ACu2tu6units • (1) 8843 or 4449 Dual Bend RRU R (2) PSU AC 02'08 units • (1) 8a43 and (1) 44 78 S 13) PSU AC 02• 08 unto • (l i 4415_ (1) 4449 and (1) 220s-44(x S (3) PSU AC 02:'138 units • 11) 4455 and (1) A449 d. (3) PSU AC OZ'lD8 wiTits (1) 4449 and (2) 22OK444t1 b (2) PSU AC 0208 wets • Up to (6) 2203f22062208 or 4102 .40B radios • (1) 4415 or 4426 radio and 11) 220rc440u & 11) PSU AC 02'OB -Future Cornparibi(rty for U63 32M C43end Radio - • IT i SM3 and 111 SPAS or 11) 444re (4'1 PSU AC13,6. (1) (1', SDX19260.43 b 11) Raycap. -Ffease we Cerrsnnc a ►ep►esenrairm tar aWlxx a( contigdwabaru S,arnsung Confgurations • I I 1 or 12) 7W ti54 32OW dual bared radio. (1) FiT4401.48A r-BRS radio. 0 i RT2201- 46A LAA radio 1 T) or (? 1 Date 2 Ok W OC reaifer. (1) SDX 19260-43' SDX 1926T-43 and (1) RaycW • 11) AWS+PCS AWSiPCS 32OW dual band radio 1 t I RT4401.48A CSRS rade- 01 RT2201-45A LAA radio, 11) Dena 20kW DC rec"w. (1) SL)X19260-43' SDXT 926T- 43 and (1) RaYrro • 111 AWS-PCS or 7001850 320W duai band radio. 0 AWVV dust band rade (1) Rario C pbd RT4401 di -411A CBRS radio, 11) RT2201-46A Ldo AA ra. (1) or (2) Delta OkW DC a4+Pa ili t rwiifiw, 0 ) SOX 191200-431 SDX1926T-43 and i 1) Raycap SSC-7002495MIX • (1) or 12) t 6OW dual band raft. (1) RT440T-48A CARS radio. 11) RT:201-46A LAA radio. 01 or (2) Delta 2.Okw DC rectifier (11 SOX 1926t7-431V SOX 1926T-43 111 Raycap -POPase we Cbrrurrsscps rsprsswrtath1r+ foracki(io.:ad crv7t5Qdy.aliari" Nokia Configurations • (4) Ajmcae Mram racos • 12 � Dual Band RaJiue- 1(x3W and 320W plus recliflers Supported dual band radios: -AHFIA AHFI9 -ANFIC •'AHLBA "AtBi.A -'A-H&CC-AHLBBA Supported Rectifiers "Del. GE -CC1 -Nokia FPAE -ftwlsir s" C<rrw;zc i * fopresamawoo for adc trerW cof*gurubms'- ttet.,< d rwa.aa azx-r,m.ka Me � o ftarr na>teK w.SCALe31'j-V 'N-d1. PMM&6,:-W"--.'-/_�.V. ItSCAr:_-1]11A+.�ic ca:,Keu:.-aoi. Ca"r'S. MM DW.ek..,rXXW ssMx,e.-2=43. 3ax,9ar-&3 rr:�oa+r Can eccowncome Oe1ra I Dow r ftvv W 2.0aw ncwwIL % cr1 rectum ei recanws Ua I-fte FI-AE -••=r&M F%uw we awwwvww �rr:E!lalebe Ion dear,• - • -■ ar""S "r.-+ •-' fnr Lour carry. 'r nr Cr":. -r o r aau -41sr ea-vrr 'e• h7. Tame Mu•rd, "6' r-•oem Fat fir-wL 7' b 44raerc 3rxr. W 1cr *roe r� MC-SP-REMI-21-00i-O4 c a Co"e rc.X• ru rwr.er rose rrea An t-aee.r % OW~ sr f <,r ^ sm ragree_4 rxawmRm. pmpgcsrr: rr Carr•MBrane Ar speescasmu are sgen a c w0• ■wmx m9ow nee erw crnwxao¢ ebm Tar the "W Sunni reaAr" ion EQUIPMENT SHROUD DETAILS (' `' SCAB*: NTS - 1 - s-O vN m3UNTED ON AN a- 0 P'CLE CLAMP, STPAP AND THRU BOLT OPTIONS A.0 10.0 (2) 2 TRADE SIZE KNOCKOUTS FOR CABLE ENTRY/ EXIT (CROSS CUT RUBBER GROMMETS INCLUDED) -T-' RJLLY VENTED WITH GRA87 ` �• COMPUANTPERF PATTERNS ?5 i I ,— 24.0 , UNIVERS,kL POLE REMOVABLE MOUNTING BRACKET PANEL ACCESS ��777, ini a 48.0 I I • I 2.5 1 TAXI PER RESISTANT LATCH 1 5 (2) 2' TRADE SIZE--" WITH PADLOCK HASP KNOCKOUTS • (Z) 2 TRADE SIZE KNOCKOUTS ii j I TAMPED. RESISTANT MTO SCREWS �.,....._...�,�_........... - a c� art f�CptS 7 - r:+.rwtw+wrrrr.r,ywrws.� - V• ! SSC-7G0249586X1X METkOCELt RAGIO CONCEALMENT MICRO 'V2 SOLUTION ""MMSCOPE verizon 175 CALKINS ROAD ROCfrESTER, NY 14623 Tectonic Tedoric Ergkiew4nq Cemdta,ta, Geobg4A• t Land Sur yont, O.H.C. Frvj•cr Cc�:dncr tnr� 36 British 61vc:. Phone- •'5'81 783-163;1 Suite 10, (8005 829-E53' Latham. NY 121 1 C www.tectonicengineen:ne.com WO NUMBER DRAWN BY REVIEWED BY 12861.035A TRR MP NO. DATE ISSUE C 5/13/26 FOR REGULATORY i 6/11/26 ADDED PAINT NOTE i UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN SEARING THE SA OF A LICENSED ENGINEER OR LAND I.RVEYOR IS A VIOLATION OF SECTION 7209 SUBDNISION 2 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS DOCUM 4-i Vi(THOUT A FACSIMILE OF THE SIGNATUFE AND AN ORIGINAL. ElA303SED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORh-'AT) 0 i ORIGINAL SIZE IN INCHES (11x17 FORMAT) SITE INFORMATION SPRING STREET DELI FUZE ID#: 16085149 MDG#: 5000958473 SITE ADDRESS UTILITY POLE# NG 7-1 ADJ TO 72 COURT ST CITY OF WATOGA SPRINGS SARATOGA COUNTY NY 12866 SHEET TITLE POLE MOUNT DETAILS SHEET NUMBER Crass�3 ANTENNA MOUNT GROUNDING PROPOSED VERIZON CONDUCTORS. #6 AWG STRANDED, WIRELESS ANTENNA INSULATED AND COPPER CABLE, SECURED TO POLE AND ANTENNA MOUNT USING UV RATED CABLE TIES ?' i I' ANTENNA GROUNDING CONDUCTORS. #6 AWG STRANDED, INSULATED AND COPPER CABLE, SECURED TO POLE AND ANTENNA MOUNT USING UV RATED CABLE TIES BOND MAIN GROUND TO NEUTRAI WIRE OF SECONDARY TRIPLE: PROPOSED HOME RUN GROUN WIRE, #2 AWG COPPE INSULATED OR #2 TINNE PROPOSED EQUIPMENT SHROUD PROPOSED LOAD CENTER PROPOSED METER -- s #6 AWG INSULATED GROUND TO —' HOME RUN FROM ALL CABLES AND METALLIC OBJECTS PROPOSED 1 /2" HIGH IMPACT PVC U—GUARD (U—MOLDING) MOLDING TO COVER GROUND DOWN WIRE ALONG BOTTOM 8' OF POLE PROPOSED INSULATED P—CLIPS/STRAPS OR STAPLES PLACED 18" APART PROPOSED MOPT TERMINAL (BY OTHERS) EXISTING GRADE STREET SIDE r PROPOSED GROUND ROD (TYP OF 2) (SEE DETAIL 3/E-1) z 6' - 0" s UTILITY POLE GROUNDING DETAIL E-1 SCALE: 3/16" = V-0" (11x17 SIZE) 3/8" = 1'-0" (22x34 SIZE) COAX GROUND KIT (TYP) -- - -- - - -- - ------ ---- - ------- 2--- a z z w z Q ANTENNA MOUNT COMPRESSION CONNECTION BY CONTRACTOR (TYP) it -SECONDARY o II �I 11 ANTENNA COAX, JUMPERS- , � L — (TYP OF 16) PROPOSED CALIBRATION CABLE — — — — — — — — — — — , (-- 7--� -------- '--- -- -�------ SMALL CELL I j C—BAND RRH I I POWER MODULE i --- I I -- _F - HI —BAND I GROUND BAR WITHIN SHROUD DOUBLE C—TAP OR COLOR CODED LONG BARREL DOUBLE LUG CONNECTION WITH NON OXIDIZING COMPOUND (TYP) #6 AWG INSULATED GROUND TO HOME RUN FROM ALL CABLES AND METALLIC OBJECTS HOME RUN GROUND WIRE, #2 AWG COPPER INSULATED OR #2 TINNED RRH 1 1 POWER MODULE I I I L---------- J l LOAD CENTER METER SOCKET GRADE , GROUND ROD (TYP) GROUND LINE #2 AWG COPPER 2 GROUNDING RISER DIAGRAM t-1 SCALE: NTS PROPOSED 100A METER (Zo(-VC-T (MILBANK P/N: U2048— APPROVED EQUAL BY UTILITY PRO 100A METE UTILITY PRO 2- 1-1 /2" CONDUIT W/ (3)# 1. CONTRACTOR TO ROUTE CONDUIT TO THE HEIGHT OF THE SECONDARY OHW AND SPOOL 10' OF CONDUCTOR ABOVE THE CONDUIT. SPLICE TO SINGLE PHASE SERVICE TO BE PERFORMED BY UTILITY PROVIDER. CONTRACTOR TO UTILIZE PEINI- ,INllj^ (OR APPROVED EQUAL) ON ALL CONNECTIONS WITHIN METER SOCKET EQUIPMENT SHROUD —54DC CABLE J a - a 0 4- N `\ 0 N 120/240V SUPPLY CABLE (TYP) PROPOSED VERIZON WIRELESS l nn A LOAD CENTER (EATON BRP1281 1 1 /2" C W/ (3) #1 P P P \ P s ONE LINE DIAGRAM E-1 SCALE: NTS kDE )THERMIC WELD (TYP) t� GROUND ROD, COPPER CLAD STEEL ROD, MIN 5/8" DIA. X 8'-0" LONG (TYP OF 2) Y 6' MIN NOTE: GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM VERTICAL. 3 GROUND ROD DETAIL E-1 SCALE: NTS PROPOSED HOMERUN GROUND WITH #2 AWG COPPER INSULATED OR CAW TINNED —1 U Le L1 L2 N PROPOSED GROUND BUS NEUTRAL BONDING SCREW verizon I 175 CALKINS ROAD I 't ROCHESTER, NY 14623 lima Tecton*ic PaAcnul. sowncom axcarnonAL snmca. Toclak EngMwAq CormAmb, Giogflb • Land Swoppm, D.P.C. Froj.cl contact Into 36 Srttihh American Siva. Phone. (518) 783-16M Suite 101 (800) 829-6531 Lothom. NY 12110 www.tec*onicengincering.com WO NUMBER DRAWN BY REVIEWED BY 12861.035A TRR MP AIA r%ATC ICCI IC 0 5/13/26 FOR REGULATORY 1 6/11/26 ADDED PAINT NOTE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 -- PROPOSED LOAD CENTER SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. O (EATON P/N: BRP12B100R) COPIES OF THIS DOCUMENT 'WITHOUT A FACSIMILE Or THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR SHALL NOT BE CONSIDERED VALID COPIES_ PROPOSED GROUNDING ELECTRODE CONDUCTOR. #2 AWG STRANDED, INSULATED 0 1 COPPER CABLE TO GROUND BUS ORIGINAL SIZE IN INCHES 4 LOAD CENTER GROUNDING (22x34 FORMAT) E-1 SCALE: NTS 0 1 ORIGINAL SIZE IN INCHES (11 x17 FORMAT) SITE INFORMATION PROPOSED SMALL CELL SPRING STREET DELI C—BAND MMU (1) DC CABLE (DELTA P/N FUZE ID#: 16085149 3799423700—S) M DG#: 5000958473 1-1 AC CABLE DELTA ` SITE ADDRESS /1 P/N 3799919300—S) 1, MICRO UTILITY POLE# NG 7-1 f P P DELTA ADVANTAGE P ADJ TO 72 COURT ST RRH % AC/DC MODULE CITY OF SARATOGA SPRINGS PROPOSED SARATOGA COUNTY Hi —BAND RRH DELTA ADVANTAGE NY 12866 P P AC/DC MODULE P + RRH SHEET TITLE L (1 ) AC CABLE (DELTA ELECTRICAL & GROUNDING P/N 3799919300—S) ++ DIAGRAMS & DETAILS I (1) DC CABLE (DELTA P/N --' 3799423700—S) SHEET NUMBER E�l