Loading...
HomeMy WebLinkAbout20260351 68 Congress Viva Empanadas Mechanical Install NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Chris Bennett Leslie DiCarlo Jeff Gritsavage Geoff Wood Karen Cavotta Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20260361 68 Congress St. Viva Empanada Equipment Installation – Exhaust Hood 68 Congress St Saratoga Springs, New York 12866 involving Architectural review of rooftop equipment installation within the Urban Core (UC) District, tax parcel #165.-7-1.11, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on May 20, 2026:  Approve the plans as submitted or shown on the attached Record of vote: motion to approve made by T Ehinger, seconded by G Wood passed 5-0 In favor: T Ehinger, CBennett, LDiCarlo, KCavotta, G Wood As a result of this decision, the applicant:  may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent CaptiveAire Systems, Inc.EQUIPMENT SPECIFICATION Exhaust Fan — Type I Hood Model: DU180HFA | Direct Drive Upblast Protect It Fire & Hood Suppression Prepared: April 2026 GENERAL INFORMATION Manufacturer CaptiveAire Systems, Inc. Model Number DU180HFA Equipment Type Direct Drive Centrifugal Upblast Exhaust Fan — Grease Rated Application Type I commercial kitchen canopy hood exhaust Mounting Rooftop — upblast discharge Code Reference MCNYS Section 506 — Exhaust Equipment PERFORMANCE DATA Airflow Capacity 3,000 CFM External Static Pressure -1.000" wc (ESP) at rated airflow Fan Speed 1,183 RPM Wheel Diameter 18-3/4" Discharge Direction Upblast — rooftop DIMENSIONS Base Footprint (L x W)32" x 32" Overall Height 36" Curb Opening 26-1/2" x 26-1/2" square Wheel Diameter 18-3/4" Unit Weight Approx. 90 lbs MECHANICAL SPECIFICATIONS CaptiveAire Systems, Inc.EQUIPMENT SPECIFICATION Make-Up Air Unit Model: A1-G10D-SC | EconAir Series Protect It Fire & Hood Suppression Prepared: April 2026 GENERAL INFORMATION Manufacturer CaptiveAire Systems, Inc. Product Line EconAir Series — Modular Rooftop Make-Up Air Model Number A1-G10D-SC Equipment Type Untempered Rooftop Make-Up Air (MUA) Fan — Direct Drive Application Replacement / supply air for Type I commercial kitchen hood Code Reference MCNYS Section 508.1 — Make-Up Air Requirements for Type I Hood PERFORMANCE DATA Design Airflow 2,800 CFM Airflow Range 500 – 2,850 CFM Air Type Untempered (ambient outdoor air) Discharge Direction Downblast — rooftop supply into kitchen External Static Pressure Per system design — adjustable via speed control MECHANICAL SPECIFICATIONS Blower Type Forward Curved, Double Inlet Centrifugal Blower Blower Size 10" (G10 blower assembly) Blower Bearings Permanently lubricated ball bearings — maintenance-free Motor Options 1/4, 1/3, 1/2, 3/4, or 1 HP Motor Phase Single Phase or Three Phase (specify at order) Drive Type Direct Drive — no belts, pulleys, or sheaves