Loading...
HomeMy WebLinkAbout20260264 4 Schuyler Dr. Equipment Install-Solar NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Chris Bennett Leslie DiCarlo Jeff Gritsavage Geoff Wood Karen Cavotta Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20260264 4 Schuyler Drive Equipment Installation – Solar Panels 4 Schuyler Drive Saratoga Springs, New York 12866 involving Architectural review of installation of roof mounted solar panels within the Urban Residential-1 (UR-1) District, tax parcel # 166.14-1-2, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on May 20, 2026:  Approve the plans as submitted or shown on the attached Record of vote: motion to approve made by T Ehinger, seconded by G Wood passed 5-0 In favor: T Ehinger, CBennett, LDiCarlo, KCavotta, G Wood As a result of this decision, the applicant:  may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent FIRST RESPONDER ACCESS AS PER THE 2020 RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019, SECTION R324.6 "ROOF ACCESS AND PATHWAYS" ROOF PANEL LAYOUT: ONT OF HOUSE PROPOSED ARRAY #1 14) REC 460W SOLAR MODULES MOUNTED PORTRAIT CONFIGURATION ON IRON RIDGE RACKING AS PER IRON RIDGE INSTALLATION MANUAL PROFESSIONAL NOTES: NOTES SYSTEM NOTES: SEAL SIGNATURESOLARPANELTOTALSYSTEMSIZE: UNAUTHORIZED ALTERATION OF NEw INSTALLATION 6.44KW DC SYSTEM / 5.32KW AC SYSTEM PEE EDWq oORADDITIONTOTHISPLAN PANEL TYPE: REC 46OW IS A VIOLA-PON OF SECTION co <,\- h'O 9 VINCENT 7209(2) OF THE NEW YORKOFPANELS: 14 RESIDENCE 1j Dwo. Br: MEM scA E: AS•NOTED STATE EDUCATION LAW. ? , M - , _ t x; ',`:ten , ' INVERTFJ2 TYPE: ENPHASE IQBX I I '. EMPIRE _i COPIES OF THIS MAP NOT w PROJECT#: ES•4392.25 - CHECKEDBY: MEM OF INVERTERS: 14 HAVING THE SEAL OF THE , z4SCHUYLERDR. ENGINEER SHALL NOT BE J' DATE: DECEMBER 10, 2025 see#' 166.14.1.2 ARRAY #1 VALID 4A .,07967'0SARATOGASPRINGS, NY muNiCiPAUTY: couNTY: AZIMUTH; 20 90FESS101 P 12866 - USA CITY OF SARATOGA SPRINGS SARATOGA # PANELS 14 DWG# S-2 SOLAR ROOF LAYOUT PLAN DWG 2OF5 IRON RIDGE RACKING Viind Speed Exposure (mph} 0 psf Snow Zane Z"- Zane 1 2 :1 10 psf SneW Zone Zone Zone 1 2 3 20 psf Snow Zone Zane Zone 1 2 3 30 psf Snow Zove Zane Zona 1 2 3 40 psf Snow Zcne Zone Zme 1 40 mph 13.5 135 i0.5 12.5 12.5 10.5 10.5 10.5 10.5 i0.0 10.0 10.0 9.0 9.0 9.0 100 mph 13.5 12.0 9.5 12.5 2.0 9.5 10.5 10.5 9.5 10.0 10.0 9.5 9.0 9.0 Ail 110 mph 13.5 11.5 9.0 12.5 11.5 9.0 0.5 10.5 9.0 10.0 10.0 9.0 9.0 9.0 9.0 Ca6egory B 120 mph 13.5 10.5 0.5 12.5 10.5 9.5 10.5 111.5 0.5 10.t1 10.0 8.5 9.0 9.0 8,5 130 mph 13.5 9.5 7.5 12.5 9.5 7.5 10.5 9.5 75 10_(1 11.5 7.5 9.0 9.0 7.5 110 mph 12.5 9.0 7.0 12.5 9.0 7.0 10.5 9.0 7.0 10.0 9.0 7.0 9.0 9.0 7.0 150 mph 11.5 8.5 6.5 11..5 8.5 6.5 1 9.5 9.5 9.5 10.0 8.5 0..5 9.0 8.5 6,5 90 mph 13.5 11.0 6.5 12.5 11.0 8.5 10.5 10.5 10.5 10.0 10.0 5 9.0 9.0 8.5 i00 mph 13.5 9.5 6.0 12.5 9.5 8.0 10.5 9.5 8.0 10.0 9.5 8.0 9.10 9.0 as 110 mph 13.0 9.5 7.5 12.5 9.5 7.5 10.5 9.5 7.5 10.0 9.5 7.5 9.0 9.0 7.5 Category C 120 mph 12.0 8.5 7.0 12.0 0.5 7.0 30.5 0.5 7.0 10.0 8.5 7.0 9.0 B.5 70 130 mph 11.0 6.4 5.5 11.0 0.0 5.5 IO.5 8.0 f1.5 95 8.0 6.5 9.0 6.0 5 i40 mph 10.0 7.5 6.0 10.0 7.5 0 10.0 7.5 6.0 9.5 7.5 6.0 8.5 7.5 60 150 mph 1 9.5 7.0 5.51 R,5 7.0 5.51 9.5 7.0 5.51 9.0 7.0 5.51 8.5 7.0 5.5 14 REC 460W SOLAR PANELS MODULES MOUNTED PORTRAIT 2X12 RIDGE BEAM CONFIGURATION ON IRON RIDGE RAILS, INSTALL AS PER DETAIL ASPHALT SINGLES (ONE LAYER) AND IRON RIDGE INSTALLATION MANUAL PLYWOOD SHEATHING ANCHOR POINTS @ 48" 2X8 WOOD FRAMING MAX SPASEIENG DETZ O 16" O.C. ROOF SECTION: NTS REC 46OW SOLAR PANEL MODULE L" BRACKET SPACED 48" O.C. MAX 3-1/2" EFFECTIVE THREAD LENGTH RAFTER PENETRATION MIN.) IRON RIDGE RAIL, INSTALL AS PER IRON RIDGE INSTALLATION MANUAL ROOFING SEALANT ALL AROUND ASPHALT SHINGLES 6" MAX. OFF ROOF SURFACE 4"Xi" STAINLESS STEEL LAG BOLTS ATTACHMENT DETAIL: NTS REVISIONS NOTES SYSTEM NOTES: PROFESSIONAL NOTES: SEAL & SIGNATURE DWG# SOLAR PANEL TOTAL SYSTEM SIZE: UNAUTHORIZED ALTERATION OF NEW ' S-36.4MCW DC SYSTEM / 5.32KW AC SYSTEM OR ADDITION TO THIS PLAN YINSTALLATION PANEL TYPE: REC 46OW IS A VIOLATION OF SECTION QP EOWg90 9 SOLAR 7209 2 OF THE NEW YORKYICENTOFPANELS: 14 ( * PANELrF11nWG. BY: MEM SCALE: AS•NOTED STATE EDUCATION LAW. I sEMPIRE'.-Y'-) , M, RESIDENCE INVERTER TYPE ENPHASE IQBX COPIES OF THIS MAP NOT F:j W '"' CHECKED BY: MEM PROJECT ES•4392.25 HAVING THE SEAL OF THE 2 ATTACHMENTOFINVERTERS: 144SCHUYLERDR. ENGINEER SHALL NOT BE DATE: DECEMBER 10, 2025 SBL#: 166.14.1.2 ARRAY VALID a 06 .- PLAN SARATOGA SPRINGS, NY AZIMUTH: 267961 3 A9 SSIO '. - 0:'.- owe. MUNICIPALITY: COUNTY: TILT: 2O .0`-: 12866 - USA CITY OF SARATOGA SPRINGS SARATOGA # PANELS 14 =- 3 O F