HomeMy WebLinkAbout20260258 115 Union Ave. Exterior Modification-Window Replacement NOD
Page 1 of 1
Tamie Ehinger, Chair
Rob DuBoff, Vice Chair
Chris Bennett
Leslie DiCarlo
Jeff Gritsavage
Geoff Wood
Karen Cavotta
Alison Dockum, Alternate
Christina Abele, Alternate
CITY OF SARATOGA SPRINGS
D ESIGN R EVIEW B OARD
❖
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x.2517
www.saratoga-springs.org
NOTICE OF DECISION
In the matter of the application
#20260258
115 Union Ave. Exterior Modification-Window Replacement
115 Union Ave.
Saratoga Springs, New York 12866
involving Historic review of window replacement within the Urban Residential-4 (UR-4) District, tax parcel #166.69-5-25, within
the City of Saratoga Springs.
In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:
Type II action – exempt from further SEQR review
And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240 -
13.9 Historic Review Applicability and Approval Standards, the Design Review Board issues the following decision on April 22,
2026:
Approve the plans with the following conditions:
In accordance with the letter from the Home Owners Association, Peerless Property Management, the window
proposed for this project will be used for replacing all replacement windows at 115 Union Ave with the exception
of any historic windows on the structure.
Record of vote:
motion to approve made by L DiCarlo, seconded by J Gritsavage passed 5-0
In favor: CBennett, LDiCarlo, JGritsavage, K Cavotta, G Wood
Recuse: TEhinger
Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and
actual work begun.
As a result of this decision, the applicant:
may proceed with the proposed project as approved
Please contact the Building Department to verify permit requirements.
Chair Received by Accounts
cc: Building Department
Accounts Dept.
Applicant/Agent
Exterior
Interior
Window 1
Options
Description:
Unit Type:
Frame Type:
Performance Options:
Select U.S. ENERGY STAR@ Climate
Zone:
2021 IECCO Climate Zone for this store
location:
Exterior Material Type:
Frame Width:
Overall Frame Width:
Overall Frame Height:
Rough Opening Width:
Rough Opening Height:
Venting Height:
Interior Checkrail Location from Sill:
Operation / Venting:
Base Frame Depth:
Base Wall Depth:
Vertical Mull Type:
Vertical Mull Option:
Vertical Mull Width:
Vertical Mull Mull Design Pressure:
Exterior Color:
Interior Color:
Foam Insulated:
Glazing Type:
Glass Strength:
Insulated Glass Options:
Low-E Glass Style:
Gas Filled:
High Altitude:
Glazing Lite Thickness:
Grille Type:
Sash Lock:
Quantity 1
PellaO Impervia@ Double -Hung
Complete Unit
Block
Standard
Northern
Climate Zone 5
Duracast@
32
64
59.5
64.5
60
Equal
30.24B4016
Double Hung
3"
1 11/16"
Factory Mull
Tight Mull
Standard Joining Mullion
20
Brown
Brown
Foam Insulated
Insulated
Annealed
Low-E
NaturalSun+ Low-E Insulating Glass
Argon
Non High Altitude
Standard Per Design (2.Smm)
No Grille
Cam -Action Lock
4 __
c+
k - ,;, `
d..... .. ... r