HomeMy WebLinkAbout2026 - 02 UDO Amendments A4 MU Comm 2026-04-21 v2Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-1
Article 4. Mixed-Use & Commercial Districts
4.1 PURPOSE STATEMENTS
4.2 USES
4.3 RESIDENTIAL MIXED-USE DISTRICTS STANDARDS
4.4 COMMERCIAL MIXED-USE DISTRICTS STANDARDS
4.5 COMMERCIAL DISTRICTS STANDARDS
4.6 GATEWAY COMMERCIAL DISTRICTS STANDARDS
4.7 GENERAL STANDARDS OF APPLICABILITY
4.1 PURPOSE STATEMENTS
A. Residential Mixed-Use Districts Purpose Statements
1. NCU Neighborhood Complementary Use District
The NCU Neighborhood Complementary Use District is intended to accommodate primarily single-family and two-
family residential development with some select and limited nonresidential uses where appropriate. Nonresidential
uses are intended to provide sales and services within walking distance of surrounding residential areas.
2. AC Arts and Culture District
The AC Arts and Culture District is intended to accommodate a variety of arts and cultural uses in order to sustain
and promote such uses within a mixed-use environment that is compatible with the character of nearby residential
neighborhoods.
3. UN Urban Neighborhood District (T-4)
The UN Urban Neighborhood District is intended to accommodate development of neo-traditional neighborhoods
with primarily residential uses incorporating a mix of unit types and small-scale commercial uses where
appropriate.
B. Commercial Mixed-Use Districts Purpose Statements
1. NC Neighborhood Center District (T-5)
The NC Neighborhood Center District is intended to accommodate a wide variety of residential and nonresidential
uses in a moderate intensity mixed-use environment. This district also focuses on providing quality streetscape
amenities and civic spaces to enhance pedestrian activity.
2. UC Urban Core District (T-6)
The UC Urban Core District accommodates the highest intensity and diversity of nonresidential and upper floor
residential uses. This district focuses on high quality design and materials consistent with historic downtown form
and promotes an active pedestrian oriented public realm.
C. Commercial Districts Purpose Statements
1. OMB Office Medical Business District
The OMB Office Medical Business District is intended to provide for high quality office and institutional developments,
such as corporate headquarters, medical and professional offices, and healthcare related institutional facilities. The
OMB District also permits a select series of supportive commercial uses.
2. WRB Water Related Business District
The WRB Water Related Business District is intended to accommodate and encourage commercial uses that are
dependent upon and supportive of activities that utilize recreational waters.
D. Gateway Districts Purpose Statements
1. GC-U Gateway Urban Commercial District
The GC-U Gateway Urban Commercial District is intended to accommodate commercial development of a moderately
urban character, creating a gateway that announces a transition from the edges of the community into more traditional
established commercial development nodes as well as into key character areas.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-2
2. GC-R Gateway Rural Commercial District
The GC-R Gateway Rural Commercial District is intended to accommodate commercial development of a suitably
rural, low-intensity character, creating a gateway at the edge of the City and into key character areas that celebrates
and preserves the natural beauty and rural character.
4.2 USES
A. Article 8 lists permitted, special, and temporary uses for the mixed-use and commercial districts.
B. In the UC District, select nonresidential uses are required on the ground floor of all facades abutting Broadway
from Van Dam Street to Spring Street. Such uses are as follows. This does not exempt any use from special use
permit approval if required by Article 8.
1. Amusement facility - indoor
2. Animal grooming establishment
3. Art gallery
4. Arts and fitness studio
5. Community center
6. Cultural facility
7. Eating and drinking establishment
8. Financial institution
9. Hotel
10. Live performance venue
11. Micro-production of alcohol
12. Office - Real estate services only
13. Personal service establishment
14. Retail goods establishment
15. Specialty food service
4.3 RESIDENTIAL MIXED-USE DISTRICTS STANDARDS
A. Residential Mixed-Use Districts Dimensional Standards
1. Table 4-A: Residential Mixed-Use Districts Dimensional Standards establishes the dimensional standards for
the residential mixed-use districts.
2. Developments are subject to the required public civic space requirements of Section 9.3.
3. In the NCU and AC Districts, nonresidential development is limited to the maximum gross floor area indicated
in Table 4-A. This restriction does not apply to institutional uses, day care centers, or lodging facilities permitted
within the district. Additional gross floor area may be permitted if, during site plan review, it is found that the
development meets the following standards:
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-3
a. The development maintains the privacy of adjacent residential lots and mitigates adverse impacts through
techniques such as decreased building height and massing, additional landscape and screening measures,
and setbacks greater than those required by the district dimensional standards.
b. Building design elements incorporate pedestrian-scale features, such as awnings and storefront windows.
c. Site illumination is designed and installed to minimize adverse impact on adjacent lots.
d. The design of the site’s circulation system provides adequate and safe access for both motor vehicles
and alternate modes of transportation, including walking and cycling. The design must minimize potentially
dangerous traffic movements and points of conflict between vehicles and pedestrians or bicyclists.
Table 4-A: Residential Mixed-Use Districts Dimensional Standards
NCU AC UN (T-4)
Bulk
Minimum Lot Area SF, SF-A: 5,000sf
2F: 6,600sf
Nonresidential: 5,000sf
SF, SF-A: 5,000sf
2F: 6,600sf
Nonresidential: 5,000sf
None
Minimum Lot Width SF, SF-A: 50’
2F: 60’
Nonresidential: 50’
SF, SF-A: 50’
2F: 60’
Nonresidential: 50’
None
Maximum Building Coverage 40%
40%
None
Maximum Impervious Surface 75% 75% 75%
Maximum Building Height 40’ 40’ 40’
Minimum Building Height N/A N/A Nonresidential: 24’
Maximum First Floor Elevation When
Principal Building Within 20’ of Side Lot
Lines - SF, SF-A, 2F Only
4’ 4’ 4’
Maximum Cumulative Area of New and
Existing One-Story Structure(s) on Any
One Lot
N/A N/A 3,000sf
Nonresidential Gross Floor Area
Maximum Per Building 2,000sf 2,000sf N/A
Setbacks
Minimum Front Setback 5’
5’
Build-to zone of 12’ to 18’
Minimum Build-Out Percentage N/A N/A 50% (does not apply to SF,
SF-A, 2F)
Minimum Interior Side Setback 5’ 5’ SF, SF-A, 2F, TH: 5’
MF, Nonresidential: 12’
Minimum Total interior Side Yard - SF, 2F
Only
12’ 12’ 12’
Minimum Corner Side Setback 8’ 8’ Residential: 12’
Nonresidential: Build-to-
zone of 12’ to 18’
Minimum Rear Setback 25’ 25’ 24’
B. Residential Mixed-Use Districts Design Standards
1. Design Standards
a. The following design standards apply in the residential mixed-use districts to new construction and to any
additions to a structure existing as of the effective date of this Ordinance that exceed 30% or more of the
existing structure’s square footage. Table 4-B: Residential Mixed-Use Districts Design Standards establishes
the design standards for the residential mixed-use districts. In the table, a “✓” indicates that the standard is
applicable in the district indicated. The absence of a “✓” indicates that the standard does not apply to the
district.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-4
b. Design standards may be exempted by the Design Review Board or Planning Board as follows:
i. Standards within the categories of Building Orientation and Site Design may be exempted by the
Planning Board.
ii. Where the Design Review Board reviews and approves development, including but not limited to
within the Historic Review Overlay District or Architectural Review Overlay District, the Design Review
Board may exempt standards in categories outside of those delineated in item i above.
iii. Where the Design Review Board does not review and approve development, the Planning Board
may exempt standards in all categories and may request a recommendation from the Design Review
Board.
c. Single-family, single-family attached, two-family, and townhouse dwellings are not subject to these
standards but rather subject to the design standards by dwelling type of Article 8. Multi-family dwellings are
subject to the design standards of Table 4-B.
Table 4-B: Residential Mixed-Use Districts Design Standards
NCU AC UN (T-4)
Building Orientation
1 All buildings must be oriented toward a primary public street. ✓ ✓ ✓
2 All public entrances must include direct pedestrian connections between street facing doors to adjacent
sidewalks. All buildings must have a public entrance from the sidewalk along the primary building facade.
Public entrances must be visually distinctive from the remaining portions of the facade along which they are
located.
✓ ✓ ✓
3 Garage doors must not be located on the front of buildings, but rather must face the side or the rear of the
property. If placement on the front of the building is unavoidable, garage doors must be located a minimum
of 15 feet behind the principal building line, and are limited to a total 20 feet in width. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-5
Table 4-B: Residential Mixed-Use Districts Design Standards
NCU AC UN
(T-4)
Facade Design
4 Building facades that abut a public right-of-way (excluding alleys) must not contain blank wall areas that
exceed 30 linear feet, measured per story parallel to the street. ✓ ✓ ✓
5 Facades abutting a public right-of-way (excluding alleys) must be divided into multiple “modules,”
expressed through significant architectural changes such as a change in materials, a change in pattern
elements such as fenestration, columns or pilasters, or a change in building setback through recesses or
projections. For buildings 150’ in length or greater, such modules may be no wider than 50 feet.
✓ ✓ ✓
6 Public entrances must include design elements to ensure clear visibility and architectural prominence, such
as:
a. Details including but not limited to awnings, arches, friezes, columns, pilasters, transom or sidelight
windows mosaic or tile work, murals, or other public art as an integral feature. b. Integral landscape or seating elements such as planters and benches or seat walls. c. Three-dimensional elements such as corner towers, porticos, arcades or colonnades.
✓
7 Buildings must be designed with consistent building materials and treatments that wrap around all facades
visible from a public street. Where material or color treatments change, there should be a significant
change in surface plane of a minimum of six inches in difference. Differing materials are encouraged to
terminate at inside corners.
✓ ✓ ✓
8 Facades must express a traditional visual distinction between the ground floor and upper stories through
architectural features or detailing, change in materials, or a change in pattern elements such as
fenestration. Where existing adjacent buildings contain such horizontal features or datum lines
distinguishing the ground floor from upper stories, new building facades must complement the heights of
such features to create visual continuity along the face of a block.
✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-6
Table 4-B: Residential Mixed-Use Districts Design Standards
NCU AC UN
(T-4)
9 Commercial storefronts must include traditional pedestrian-oriented elements such as display windows,
knee walls, transoms, and/or cornices. ✓ ✓ ✓
10 All architectural openings, including windows, doorways, arches, porch framing, etc. should be sympathetic
to the repetition of prevailing horizontal or vertical elements of the structure. ✓ ✓ ✓
11 Window shutters, whether functional or used as a decorative element, must be used consistently across the
building facade, and must be proportioned so as to cover the window opening when closed. ✓ ✓ ✓
12 Mechanical equipment and structural components such as vents must be located and screened to minimize
visibility. ✓ ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-7
Table 4-B: Residential Mixed-Use Districts Design Standards
NCU AC UN
(T-4)
Fenestration Design
13 The ground floor of the front facade must maintain a minimum transparency of 35%, measured between
two and ten feet in height. ✓ ✓ ✓
14 Upper floors of the front facade must maintain a minimum transparency of 15% of the wall area of the story ✓ ✓ ✓
Roof Design
15 Roof forms may include symmetrical pitched roofs or flat roofs with cornice treatments. Slopes of pitched
roofs should be no less than 5:12, and that porch roofs should be shed roofs with pitches no less than 3:12. ✓
16 Rooflines of 100’ in length or more must be varied through the use of architectural design elements such as
dormers, gables, or projected wall features. Such elements of variation may be no wider than 50’. ✓ ✓ ✓
17 Reflective roof surfaces that produce glare are prohibited, except for cool roofs intended to radiate
absorbed or non-reflected solar energy and reduce heat transfer to the building. ✓ ✓ ✓
18 Where parapet walls are used, they must feature three-dimensional cornice treatments or other shadow-
creating details along the top. ✓ ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-8
Table 4-B: Residential Mixed-Use Districts Design Standards
NCU AC UN
(T-4)
Site Design
19 Sites must be designed to ensure safe pedestrian and bicycle access from the public right-of-way, and safe
pedestrian and bicycle circulation within the development. ✓ ✓ ✓
20 A cohesive character must be established through the use of coordinated hardscape (paving materials,
lighting, street furniture, etc.) and landscape treatments within the development. ✓ ✓ ✓
21 Vehicular access to parking and service areas must be provided from an alley wherever possible. This also
applies to corner lots served by alley access. ✓ ✓ ✓
2. Prohibited Building Materials
a. In the residential mixed-use districts, the following building materials are prohibited on any nonresidential
facade facing a public right-of-way (excluding alleys) or any facade that abuts the lot line of a residential
district. However, such materials may be used as decorative or detail elements for up to 25% of the facade,
or as part of the exterior construction that is not used as a surface finish material, unless a review by the
Design Review Board, prior to site plan review, approves a greater percentage of use of these materials.
Residential structures are subject to the standards for the dwelling type per Article 8.
i. Plain concrete masonry units (CMU)
ii. Corrugated metal
iii. Exposed aggregate concrete wall panels
iv. T-111 composite plywood siding
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-9
v. Plastic
vi. Asphalt or vinyl siding
vii. Exterior insulation and finish system (E.I.F.S.)
viii. Cedar shakes as roofing material
ix. Architectural foam
b. In the Historic Review Overlay District and the Architectural Review Overlay District, the Design Review
Board must approve the use or any change in building materials as part of design review.
4.4 COMMERCIAL MIXED-USE DISTRICTS STANDARDS
A. Commercial Mixed-Use Districts Dimensional Standards
1. Table 4-C: Commercial Mixed-Use Districts Dimensional Standards establishes the dimensional standards
for the commercial mixed-use districts.
2. Permitted single-family, single-family attached, two-family, and townhouse dwellings are not subject to these
standards but rather subject to the standards of the UN District for such dwelling types.
3. Developments are subject to the required public civic space requirements of Section 9.3.
Table 4-C: Commercial Mixed-Use Districts Dimensional Standards
NC (T-5) UC (T-6)
Bulk
Maximum Building Height
1.1 times the width of the right-of-way or
50’, whichever is less
A height bonus may be approved - See
Section 4.4.B below
1.1 times the width of the right-of-way or
70’, whichever is less
A height bonus may be approved - See
Section 4.4.B below
Minimum Building Height 24’ 24’
Building Height Stepback Building facade above the maximum base height must be set back a minimum of 10’
from ground floor facade line
Optional Height Exception
Buildings may exceed maximum height
by up to 6’ for no more than 25% of the
linear facade width, to a maximum depth
of 30’
Buildings may exceed maximum height
by up to 8’ for no more than 35% of the
linear facade width, to a maximum depth
of 50’
Optional Corner Lot Element Limited in width and depth to a maximum of 25% of the building width. May exceed
height at which stepback is required, but may not exceed the overall building height
Maximum Cumulative Area of New and Existing One-Story Structure(s) on Any One Lot 3,000sf 1,500sf
Setbacks
Minimum Setback from a Lot Line Abutting any
Public Right-of-Way (Excluding Alleys)
Right-of-way 40’ or less in width: 5’ to
12’ build-to zone
Right-of way width greater than 40’: 0’ to
12’ build-to zone
Right-of-way 40’ or less in width: 5’ to 12’
build-to zone
Right-of way width greater than 40’: 0’ to
12’ build-to zone
Minimum Build-Out Percentage Abutting any
Public Right-of-Way (Excluding Alleys)
70% (does not apply to SF, SF-A, 2F,
TH) 80%
Minimum Interior Side Setback 0’ 0’
Minimum Rear Setback 0’ 0’
** In the UC District, select areas of the district require ground floor commercial uses per section 4.2.B.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-10
BULK AND AREA HEIGHT EXCEPTIONS
B. Commercial Mixed-Use Districts Development Bonus
In order to exceed the maximum building height listed in Table 4-C, a proposed development must meet additional
standards listed in this section.
1. Height Bonus Applicability
Up to 15 feet of additional building height may be granted through a voluntary bonus system. To obtain a
development bonus, one or more actions in Table 4-D are required.
Eligibility for and authorization of any height bonus permitted shall be determined by the Planning Board.
The Design Review Board shall review the architectural design implications of the additional height.
2. Application of Bonus PointsSketch Plan Review
Applicants proposing to utilize a height bonus shall present the request during sketch plan review prior to
submission of a complete site plan or special use permit application.
Bonuses for additional height are subject to the process of this section, and earned and applied as indicated in
Table 4-D.
a. a. The sketch plan review is intended to:
i. identify potential issues relating to building height and massing,
ii. evaluate the appropriateness of the requested height bonus, and
i.iii. provide early guidance to the applicant prior to preparation of detailed plans.The Design Review
Board will determine the amount of height, up to the maximum of 15 feet, that the development
is eligible for. As part of the request for additional height, the applicant must submit mass and
scale drawings of the proposed development.
b. Sketch plan review shall be advisory only and shall not constitute approval of a height bonus, site plan,
or special use permit.Following the Design Review Board determination of the eligible amount of height bonus
and partial approval of the mass and scale drawings, the approval will be forwarded to the Planning Board.
The Planning Board will make a determination that the bonus action(s) proposed by the applicant meet the
standards and intent of this section, the zoning district, and this Ordinance to achieve the height bonus.
c. c. Joint Concept Review. Where a development proposes a height bonus within the Historic District
or Architectural District, the Planning Board may conduct a joint sketch plan review with the Design
Review Board. The purpose of this review is to provide early guidance regarding:
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-11
i. building massing and scale
ii. architectural character
iii. streetscape compatibility
iv. potential design considerations associated with the proposed height bonus.
d. Submission Requirements. The sketch plan submission shall include:
i. Conceptual site layout and elevations showing the base maximum and proposed bonus height
ii. General massing diagram illustrating the building envelope
iii. Streetscape perspective drawings illustrating the relationship to buildings
iv. Narrative describing the eligibility for the height bonus
c.e. For items 1 and 2 of Table 4-D for affordable housing, the additional height is the full bonus amount (15
feet).
fd. . For items 3 through 67 of Table 4-D, the additional building height is awarded by a point system. Acquired
points may be used to increase building height by 1 foot for each point earned, up to the maximum height
bonus the Design Review Planning Board has approved, up to the maximum of 15 feet.
3. Height Bonus Determination
Eligibility for and authorization of any height bonus permitted under this section shall be determined by the
Planning board as part of site plan or special use permit review.
a. Planning Board Findings. In determining whether to grant a height bonus, the Planning Board shall
evaluate:
i. Compliance with all applicable zoning regulations
ii. Eligibility for the specific height bonus provisions established in this section.
iii. Consistency with adopted planning policies and public benefits associated with the bonus.
b. Design Review Board Referral. Where a project utilizing a height bonus is located within the Historic
District or Architectural District, the Planning Board shall refer the proposed building design to the
Design Review Board for advisory review prior to the final site plan approval.
The Design Review Board shall transmit written recommendations to the Planning Board within 30 days
of referral unless extended by mutual agreement
c. Scope of DRB Review. The Design Review Board shall review the design of the building and may
provide recommendations regarding:
i. Articulation of upper stories
ii. Façade composition and rhythm
iii. Roof form and skyline profile
iv. Step-backs or transitions between building levels
v. Exterior materials and detailing
vi. Visual compatibility with surrounding buildings
d. Limitations of DRB Authority. The Design Review Board’s review shall address design and visual
integration of the additional height only and shall not regulate zoning height limits, density or floor area,
building placement or setbacks, or site circulation or access.
4. Final Decision
The Planning Board shall make the final decision regarding site plan approval and the granting of any height
bonus.
Nothing in this section shall be construed as granting the Design Review Board authority to approve, deny, or
condition a height bonus.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-12
Table 4-D: Commercial Mixed-Use Districts Development Bonus
Bonus Action Bonus Awarded
1 Affordable Housing Option A. Devote 20% of Gross Floor Area (calculated to number of
units) for the number of floors above the base maximum height to affordable housing, using
local unit size averages. Units must be set aside for households earning 60% AMI or less for a
minimum of 30 years. Example: UC District Maximum Height with Bonus (70’ maximum + 15’ additional = 85’)
Additional 15’ would typically be used to build one additional floor, so 20% of the units on one
floor of the building must be devoted to affordable housing.
Full bonus (15’ of height)
2 Affordable Housing Option B. Devote 5% of Gross Floor Area (calculated to number of units)
of the total building to affordable housing, using local unit size averages. A minimum of 80% of
the affordable units must be set aside for households earning 80% AMI or less, with no more
than 20% set aside for households earning between 81% and 110% AMI, for a minimum of 30
years.
Full bonus (15’ of height)
3 Provision of Public Civic Space. An additional 5% or more of total lot area is devoted to
public civic space above the public civic space required by Section 9.3.
Up to 5 points
4 High Performance Construction I. Points are awarded on a sliding scale based on level of
certification the building is designed to achieve: certified, silver, platinum, gold. Alternatively, up
to five bonus points may be awarded for building that are designed to meet or exceed the
provisions of the NY Stretch Energy Code, which includes elements more stringent than the base
Energy Code that is in effect in NYS at the time of construction. An evaluation from a certified
third party that demonstrates that buildings and sites meet LEED Certified standards (US Green
Building Council); however, LEED certification is encouraged, but not required. An alternate
sustainability rating system may be used, subject to approval by the City, and requires an
evaluation from a certified third party.
NC: Up to 5 points
UC: Up to 5 points
5 High Performance Construction II. Up to five bonus points are also available for buildings that
utilize air source or ground source heat pumps as their primary source for heating and cooling. Up to 5 points
56 Net-Zero Construction. Zero net energy consumption, meaning the total amount of energy
used by the building on an annual basis is equal to the amount of renewable energy created on
the site, or in other definitions by renewable energy sources off-site. An evaluation from a
certified third party is required. Buildings that supplement on-site energy production with
purchases of renewable energy from off-site sources in order to meet the zero energy definition
are also eligible.
NC: Up to 8 points
UC: Up to 10 points
67 Community Space. Community space is provided for residents of the City, including meeting
space and/or performance space. A management plan must be submitted, the space must be
deed restricted to remain in perpetuity for the community’s use, and must be actively marketed
to the community.
Up to 5 points
C. Commercial Mixed-Use Districts Design Standards
1. Design Standards
a. The following design standards apply in the commercial mixed-use districts to new construction and to
any additions to a structure existing as of the effective date of this Ordinance that exceed 30% or more of the
existing structure’s square footage. Table 4-E: Commercial Mixed-Use Districts Design Standards establishes
the design standards for the commercial mixed-use districts. In the table, a “✓” indicates that the standard is
applicable in the district indicated. The absence of a “✓” indicates that the standard does not apply to the
district.
b. Design standards may be exempted by the Design Review Board or Planning Board as follows:
i. Standards within the categories of Building Orientation and Site Design may be exempted by the
Planning Board.
ii. Where the Design Review Board reviews and approves development, including but not limited to
within the Historic Review Overlay District or Architectural Review Overlay District, the Design Review
Board may exempt standards in categories outside of those delineated in item i above.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-13
iii. Where the Design Review Board does not review and approve development, the Planning Board
may exempt standards in all categories and may request a recommendation from the Design Review
Board.
c. Single-family, single-family attached, two-family, and townhouse dwellings are not subject to these
standards but rather subject to the design standards by dwelling type of Article 8. Multi-family dwellings are
subject to the design standards of Table 4-E.
Table 4-E: Commercial Mixed-Use Districts Design Standards
NC (T-5) UC (T-6)
Building Orientation
1 All buildings must be oriented toward a primary public street. ✓ ✓
2 All public entrances must include direct pedestrian connections between street facing doors to adjacent sidewalks, and
may not be set back more than ten feet from the building line. ✓ ✓
3 Ground floor entrances into individual residential units must be between 2’ and 7’ above sidewalk grade. Where
residential units are located below sidewalk grade, a below grade entrance is permitted, which shall be between 1’ and
3’ below sidewalk grade. ✓ ✓
4 Garage doors must not be located on the front of buildings, but rather must face the side or the rear of the property. If
placement on the front of the building is unavoidable, garage doors must be located a minimum of 15 feet behind the
principal building line, and are limited to a total 20 feet in width. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-14
Table 4-E: Commercial Mixed-Use Districts Design Standards
NC
(T-5)
UC
(T-6)
Building Form and Facade Design
5 Building facades that abut a public right-of-way (excluding alleys) must not contain blank wall areas that exceed 30
linear feet, measured per story parallel to the street. ✓ ✓
6 Facades must be divided into multiple “modules,” expressed through significant architectural changes such as a
change in materials, a change in pattern elements such as fenestration, columns or pilasters, or a change in building
setback through recesses or projections. For buildings 150’ in length or greater, such modules may be no wider than 50
feet.
✓ ✓
7 Facades must express a traditional visual distinction between the ground floor and upper stories through architectural
features or detailing, change in materials, or a change in pattern elements such as fenestration. Where existing
adjacent buildings contain such horizontal features or datum lines distinguishing the ground floor from upper stories,
new building facades must match the heights of such features to create visual continuity along the face of a block.
✓ ✓
8 Public entrances must incorporate at least two of the following design elements to ensure clear visibility and
architectural prominence:
a. Details including but not limited to awnings, arches, friezes, columns, pilasters, transom or sidelight windows
mosaic or tile work, murals, or other public art as an integral feature. b. Integral landscape or seating elements such as planters and benches or seat walls. c. Three-dimensional elements such as corner towers, porticos, arcades or colonnades.
✓ ✓
9 Commercial storefronts must include traditional pedestrian-oriented elements such as display windows, knee walls,
transoms and cornices. ✓ ✓
10 The ground floor of a building facade abutting a public right-of-way (excluding alleys) must maintain a minimum
transparency of 50%, measured between two feet and ten feet in height. ✓ ✓
11 The upper floors of a building facade abutting a public right-of-way (excluding alleys) must maintain a minimum
transparency of 15% of the wall area of the story. ✓ ✓
12 The ground floor of a building facade abutting a rear parking area that contains a public entrance must maintain a
minimum transparency of 20%, measured between two and ten feet in height. ✓ ✓
13 All architectural openings, including windows, doorways, arches, porch framing, etc. must maintain a height equal to or
greater than their width to emphasize the verticality of such elements. ✓ ✓
14 Window shutters, whether functional or used as a decorative element, must be used consistently across the building
facade, and must be proportioned so as to cover the window opening when closed. ✓ ✓
15 Buildings must be designed with consistent building materials and treatments that wrap around all facades visible from
a public street. Where material or color treatments change, there should be a significant change in surface plane of a
minimum of six inches in difference. Differing materials are encouraged to terminate at inside corners. ✓ ✓
16 Mechanical equipment and structural components such as vents must be located and screened to minimize visibility. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-15
Table 4-E: Commercial Mixed-Use Districts Design Standards
NC
(T-5)
UC
(T-6)
Roof Design
17 Roof forms may include symmetrical pitched roofs or flat roofs with cornice treatments. Slopes of pitched roofs may not
be less than 5:12, except that porch roofs may be sheds with pitches not less than 3:12. ✓ ✓
18 Rooflines of 100’ in length or more must be varied through the use of architectural design elements such as dormers,
gables, or projected wall features. Such elements of variation may be no wider than 50’. ✓ ✓
19 Reflective roof surfaces that produce glare are prohibited, except for cool roofs intended to radiate absorbed or non-
reflected solar energy and reduce heat transfer to the building. ✓ ✓
20 Where parapet walls are used, they must feature three-dimensional cornice treatments or other shadow-creating
details along their tops. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-16
Table 4-E: Commercial Mixed-Use Districts Design Standards
NC
(T-5)
UC
(T-6)
Site Design
21 Sites must be designed to ensure safe pedestrian and bicycle access from the public right-of-way, and safe pedestrian
and bicycle circulation within the development. ✓ ✓
22 A cohesive visual character must be maintained through the use of coordinated hardscape (paving materials, lighting,
street furniture, etc.) and landscape treatments within the development. ✓ ✓
23 Off-street parking and traffic flow must not interfere with the flow of pedestrian travel or otherwise detract from the
aesthetic character of a development or redevelopment. ✓ ✓
24 Vehicular access to parking and service areas must be provided from an alley wherever possible. This also applies to
corner lots served by alley access. ✓ ✓
2. Prohibited Building Materials
a. In the commercial mixed-use districts, the following building materials are prohibited on any nonresidential
facade facing a public right-of-way (excluding alleys) or any facade that abuts the lot line of a residential
district. However, such materials may be used as decorative or detail elements for up to 25% of the facade,
or as part of the exterior construction that is not used as a surface finish material, unless a review by the
Design Review Board, prior to site plan review, approves a greater percentage of use of these materials.
Residential structures are subject to the standards for the dwelling type per Article 8.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-17
i. Plain concrete masonry units (CMU)
ii. Corrugated metal
iii. Exposed aggregate concrete wall panels
iv. T-111 composite plywood siding
v. Cedar shakes as roofing material
vi. Plastic
vii. Asphalt or vinyl siding
viii. Exterior insulation and finish system (E.I.F.S.)
ix. Architectural foam
b. In the Historic Review Overlay District and the Architectural Review Overlay District, the Design Review
Board must approve the use or any change in building materials as part of design review.
4.5 COMMERCIAL DISTRICTS STANDARDS
A. Commercial Districts Dimensional Standards
1. Table 4-F: Commercial Districts Dimensional Standards establishes the dimensional standards for the
commercial districts.
2. Permitted single-family, single-family attached, two-family, and townhouse dwellings are not subject to these
standards but rather subject to the standards of the UN District for such dwelling types.
Table 4-F: Commercial Districts Dimensional Standards
OMB WRB
Bulk
Minimum Lot Area 10,000sf 20,000sf
Minimum Lot Width 100’ 200’
Maximum Building Coverage 40% 45%
Maximum Impervious Surface 70% 70%
Maximum Building Height 40’ 40’
Setbacks
Minimum Front Setback 40’ 40’
Minimum Interior Side Setback 15’, unless abutting a residential
district, then 40’
15’, unless abutting a residential
district, then 40’
Minimum Corner Side Setback 40’ 40’
Minimum Rear Setback 25’, unless abutting a residential
district, then 50’
25’, unless abutting a residential
district, then 50’
B. Commercial Districts Design Standards
1. Design Standards
a. The following design standards apply in the commercial districts to new construction and to any additions
to a structure existing as of the effective date of this Ordinance that exceed 30% or more of the existing
structure’s square footage. Table 4-G: Commercial Districts Design Standards establishes the design
standards for the commercial districts. In the table, a “✓” indicates that the standard is applicable in the district
indicated. The absence of a “✓” indicates that the standard does not apply to the district.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-18
b. Design standards may be exempted by the Design Review Board or Planning Board as follows:
i. Standards within the category of Site Design may be exempted by the Planning Board.
ii. Where the Design Review Board reviews and approves development, including but not limited to
within the Historic Review Overlay District or Architectural Review Overlay District, the Design Review
Board may exempt standards in categories outside of those delineated in item i above.
iii. Where the Design Review Board does not review and approve development, the Planning Board
may exempt standards in all categories and may request a recommendation from the Design Review
Board.
c. Single-family, single-family attached, two-family, and townhouse dwellings are not subject to these
standards but rather subject to the design standards by dwelling type of Article 8. Multi-family dwellings are
subject to the design standards of Table 4-G.
Table 4-G: Commercial Districts Design Standards
OMB WRB
Facade Design
1 Building facades that abut a public right-of-way (excluding alleys) must not contain blank wall areas that
exceed 30 linear feet, measured per story parallel to the street. ✓ ✓
2 Facades abutting a public right-of-way (excluding alleys) must be divided into multiple “modules,”
expressed through significant architectural changes such as a change in materials, a change in pattern
elements such as fenestration, columns or pilasters, or a change in building setback through recesses or
projections. For buildings 150’ in length or greater, such modules may be no wider than 50 feet.
✓ ✓
3 Building materials and visual elements used on the primary building facade must continue on all building
facades that are visible from a public right-of-way. ✓ ✓
4 Mechanical equipment and structural components such as vents must be located and screened to minimize
visibility. ✓ ✓
Fenestration Design
5 The ground floor of the front facade must maintain a minimum transparency of 30%, measured between
two and ten feet in height. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-19
Table 4-G: Commercial Districts Design Standards
OMB WRB
Site Design
6 Sites must be designed to ensure safe pedestrian and bicycle access from the public right-of-way, and safe
pedestrian and bicycle circulation within the development. ✓ ✓
7 A cohesive character must be established through the use of coordinated hardscape (paving materials,
lighting, street furniture, etc.) and landscape treatments within the development. ✓ ✓
2. Prohibited Building Materials
a. In the commercial districts, the following building materials are prohibited on any nonresidential facade
facing a public right-of-way (excluding alleys) or any facade that abuts the lot line of a residential district.
However, such materials may be used as decorative or detail elements for up to 25% of the facade, or as part
of the exterior construction that is not used as a surface finish material, unless a review by the Design Review
Board, prior to site plan review, approves a greater percentage of use of these materials. Residential structures
are subject to the standards for the dwelling type per Article 8.
i. Plain concrete masonry units (CMU)
ii. Corrugated metal
iii. Exposed aggregate concrete wall panels
iv. T-111 composite plywood siding
v. Cedar shakes as roofing material
vi. Plastic
vii. Asphalt or vinyl siding
viii. Exterior insulation and finish system (E.I.F.S.)
ix. Architectural foam
b. In the Historic Review Overlay District and the Architectural Review Overlay District, the Design Review
Board must approve the use or any change in building materials as part of design review.
4.6 GATEWAY COMMERCIAL DISTRICTS STANDARDS
A. Gateway Commercial Districts Dimensional Standards
1. Table 4-H: Gateway Commercial Districts Dimensional Standards establishes the dimensional standards for
the gateway commercial districts.
2. Where allowed in the GC-U district, single-family, single-family attached, two-family, and townhouse
dwellings are not subject to the dimensional standards of Table 4-H, but rather are subject to the dimensional
standards of the UN District for such dwelling types as specified in Table 4-A.
3. Where allowed in the GC-R district, single-family, single-family attached, two-family, and townhouse
dwellings are subject to the dimensional standards of Table 4-H, with the following exceptions:
a. Minimum building height shall not apply.
b. Dwellings shall be located behind the primary commercial or mixed use building of the development.
The minimum front setback shall be 20 feet from the rear of the primary commercial or mixed use
building, or 40 feet from a right-of-way within the development, whichever is greater.
c. Maximum density of residential dwelling units is subject to Section 4.6.A.4
4. The maximum density of residential dwelling units on any lot within the GC-R district or the portion of a lot
within the GC-R district shall be 1 dwelling unit per 15,000 square feet of lot area within the district. Where the
calculation of allowed number of dwelling units results in a fraction of a dwelling unit, the result shall be rounded
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-20
down to the nearest whole number. The resultant number of dwelling units permitted on the lot may be divided
amongst permitted building types.
5. The area designated as GC-R bound by Crescent Avenue to the north, Route 9 to the west, and lands
currently zoned as INST-PR to the east and approximately 3,300 feet to the south are subject to the dimensional
standards of Table 4-H, with the following exceptions:
a. Buildings shall include two usable stories. Building footprints greater than 20,000 square feet shall have
a minimum of 30% of each structure as 2 stories. A typical rural roof form shall also be applied to this
additional story.
b. The minimum front setback shall be 60 feet.
Table 4-H: Gateway Commercial Districts Dimensional Standards
GC-U GC-R
Bulk
Minimum Lot Area 10,000sf 20,000sf*
Minimum Lot Width 75’ 100’
Maximum Building Coverage 45% 35%
Maximum Impervious Surface 85% 60%
Minimum Building Height 24’ 18’*
Maximum Building Height 40’ 40’
Setbacks
Minimum Front Setback Build-to zone of 25’ to 40’ 40’*
Minimum Front Build-Out Percentage 50% N/A
Minimum Interior Side Setback 15’, unless abutting a residential
district, then 40’
20’, unless abutting a residential
district, then 40’
Minimum Corner Side Setback 25’ 40’
Minimum Rear Setback 25’, unless abutting a residential
district, then 50’
25’, unless abutting a residential
district, then 50’
* See exceptions to these requirements as specified in Section 4.6.A
B. Gateway Commercial Districts Design Standards
1. Design Standards (Amended 4/4/2023)
a. The following design standards apply in the gateway commercial districts to new construction and to any
additions to a structure existing as of the effective date of this Ordinance that exceed 30% or more of the
existing structure’s square footage. Table 4-I: Gateway Commercial Districts Design Standards establishes
the design standards for the gateway commercial districts. In the table, a “✓” indicates that the standard is
applicable in the district indicated. The absence of a “✓” indicates that the standard does not apply to the
district.
b. Design standards may be exempted by the Design Review Board or Planning Board as follows:
i. Standards within the category of Site Design may be exempted by the Planning Board.
ii. Where the Design Review Board reviews and approves development, including but not limited to
within the Historic Review Overlay District or Architectural Review Overlay District, the Design Review
Board may exempt standards in categories outside of those delineated in item i above.
iii. Where the Design Review Board does not review and approve development, the Planning Board
may exempt standards in all categories and may request a recommendation from the Design Review
Board.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-21
iv. Design standards in the GC-R District may be exempted by the Design Review Board or Planning
Board with a written explanation detailing the exemption as follows:
a. The uses in the structure are unique and preclude meeting the rural design standards of the
ordinance; or
b. The lot configuration is unique and precludes meeting the rural character of the ordinance; or
c. That there are extraordinary circumstances unique to the parcel that demonstrate that the design
standards cannot meet the rural character objectives of the ordinance.
c. Single-family, single-family attached, two-family, and townhouse dwellings are not subject to these
standards but rather subject to the design standards by dwelling type of Article 8. Multi-family dwellings are
subject to the design standards of Table 4-I.
d. The area designated as GC-R bound by Crescent Avenue to the north, Route 9 to the west, and lands
currently zoned as INST-PR to the east and approximately 3,300 feet to the south shall incorporate the
following design standards in addition to the GC-R standards listed below:
i. Pedestrian systems should be trails that link commercial nodes to other use areas (ie.
Neighborhoods). Trails shall meet the requirements under section 18.5.
SOUTH BROADWAY (Rt. 9) GC-R GATEWAY BOUND BY CRESECENT AVE: CONCEPTUAL PLAN
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-22
Table 4-I: Gateway Commercial Districts Design Standards
GC-U GC-R
Facade Design
1 Building facades that abut a public right-of-way (excluding alleys) must not
contain blank wall areas that exceed 30 linear feet, measured per story parallel
to the street. ✓ ✓
2 Facades abutting a public right-of-way (excluding alleys) must be divided into
multiple “modules,” expressed through significant architectural changes such
as a change in materials, a change in pattern elements such as fenestration,
columns or pilasters, or a change in building setback through recesses or
projections. For buildings 80’ in length or greater, such modules may be no
wider than 40 feet.
✓ ✓
3 Commercial storefronts must include traditional pedestrian-oriented elements
such as display windows, bulkheads, transoms, and cornices. ✓ ✓
4 All architectural openings, including windows, doorways, arches, porch
framing, etc. must maintain a height equal to or greater than their width to
emphasize the verticality of such elements. ✓ ✓
5 Window shutters, whether functional or used as a decorative element, must be
used consistently across the building facade, and must be proportioned so as
to cover the window opening when closed. ✓ ✓
6 Buildings must be designed with consistent building materials and treatments
that wrap around all facades visible from a public street. Where material or
color treatments change, there should be a significant change in surface plane
of a minimum of six inches in difference. Differing materials are encouraged to
terminate at inside corners.
✓ ✓
7 Mechanical equipment and structural components such as vents must be
located and screened to minimize visibility. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-23
Table 4-I: Gateway Commercial Districts Design Standards
GC-U GC-R
Fenestration Design
8 The ground floor of the front facade must maintain a minimum transparency of
25%, measured between two and ten feet in height. ✓
9 The ground floor of the front facade must maintain a minimum transparency of
40%, measured between two and ten feet in height. ✓
Roof Design
10 Buildings must exhibit a typical rural, pitched roof form, including but not
limited to gabled, hipped, gambrel, and barn roof forms. ✓
11 Roof forms may include symmetrical pitched roofs or flat roofs with cornice
treatments. Slopes of pitched roofs may not be less than 5:12, except that
porch roofs may be sheds with pitches not less than 3:12. ✓
12 Where parapet walls are used, they must feature three-dimensional cornice
treatments or other shadow-creating details along their tops. ✓
13 Reflective roof surfaces that produce glare are prohibited, except for cool roofs
intended to radiate absorbed or non-reflected solar energy and reduce heat
transfer to the building. ✓ ✓
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-24
Table 4-I: Gateway Commercial Districts Design Standards
GC-U GC-R
Site Design
14 Sites must be designed to ensure safe pedestrian and bicycle access from the
public right-of-way, and safe pedestrian and bicycle circulation within the
development. ✓ ✓
15 Vehicular and pedestrian circulation systems must reflect a rural character
through the use of curvilinear forms that acknowledge and work to
complement site features such as vegetation and topography.
✓
16 Off-street parking and traffic flow must not interfere with the flow of pedestrian
travel or otherwise detract from the aesthetic character of a development or
redevelopment. All off-street parking must be screened or aligned so that light
from vehicle headlights do not adversely impact abutting properties.
✓ ✓
17 Existing on-site vegetation and topography must be preserved to the extent
practicable. Where topography must be altered, cut and fill slopes must be
graded to mimic existing slopes, at a maximum of 1:5, and blend smoothly into
the surrounding landform.
✓
18 Site designs must employ techniques such as variation in the height and
placement of buildings, as well as clustering of structures and vegetation to
reinforce the rural character of the area, and to help preserve scenic views of
the surrounding natural landscape.
✓
19 Shared driveways are strongly recommended with the minimum spacing
between adjacent driveways on the same side of the street at 500 feet. Access
connections on opposite sides of the street should be aligned or off-set so as
to eliminate left-turn conflicts. The Planning Board, as part of site plan review,
should evaluate the effect of proposed driveway locations on development of
abutting properties. Proposals for shared driveways may require cross access
easements.
✓
2. Prohibited Building Materials
a. In the gateway commercial districts, the following building materials are prohibited on any nonresidential
facade facing a public right-of-way (excluding alleys) or any facade that abuts the lot line of a residential
district. However, such materials may be used as decorative or detail elements for up to 25% of the facade,
or as part of the exterior construction that is not used as a surface finish material, unless a review by the
Design Review Board, prior to site plan review, approves a greater percentage of use of these materials.
Residential structures are subject to the standards for the dwelling type per Article 8.
i. Plain concrete masonry units (CMU)
ii. Corrugated metal
iii. Exposed aggregate concrete wall panels
iv. T-111 composite plywood siding
v. Cedar shakes as roofing material
vi. Plastic
vii. Asphalt or vinyl siding
viii. Exterior insulation and finish system (E.I.F.S.)
ix. Architectural foam
b. In the Historic Review Overlay District and the Architectural Review Overlay District, the Design Review
Board must approve the use or any change in building materials as part of design review.
Article 4. Mixed-Use & Commercial Districts
City of Saratoga Springs UDO April 2023 4-25
4.7 GENERAL STANDARDS OF APPLICABILITY
A. Site Development Standards
See Article 9 for additional on-site development standards and requirements, such as exterior lighting, accessory
structures and uses, and permitted encroachments.
B. Off-Street Parking and Loading
See Article 10 for off-street parking and loading standards and requirements.
C. Landscape
See Article 11 for landscape, buffering, and screening standards and requirements.
D. Signs
See Article 12 for standards governing signs.