Loading...
HomeMy WebLinkAbout20260098 56 Duplainville Rd Regeneron Sketch Plan Master Plan====== FUTURE 115kV FEED FUTURE CITY DOMESTIC COVERED WALKWAY GUARD HOUSE & PAVEMENT ADDITIONS (PREVIOUSLY APPROVED) 20-INCH WATER MAIN TO SCWA 2 COMPACTORS OPEN CELL COOLING TOWER 2 COMPACTORS RAIL REMOVAL DUPLAINVILLE R O A D ADAMS ROAD M A R S E L D R I V E COMPACTORS 2 COMPACTORS AND FOOD DELIVERY AREA OF DISTURBANCE FOR STORMWATER POLLUTION PREVENTION PLAN AREA OF DISTURBANCETEMP GENERATOR BULK CHEM AREA OF DISTURBANCE PIPE RACK BULK CHEM GUARD HOUSE & PAVEMENT ADDITIONS DISINFECTION AND WATER METER BDG RELOCATED ACCESS ROAD BACKUP GENERATORS 115 kV SUBSTATION TRANSFORMERS TRANSFORMERS 8-INCH SANITARY FORCEMAIN TO CITY SYSTEM 8-INCH SANITARY FORCEMAIN TO CITY SYSTEM PUMP STATION BULK GAS 200,000 GALLON WATER TANK WITH FIRE PUMP AND GENERATOR BULK CHEM SECURITY FENCE SECURITY FENCE E E E E PROPOSED PARKING GARAGE PREVIOUSLY APPROVED BUILDING ADDITION DW D W D W W W W W W W W W W W W W EXISTING PRINCIPAL BUILDING FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM F M F M F M F M F M F M F M F M F M F M FM F M F M F M FM FM FM (2) 425,000 GALLON POTABLE / PROCESS WATER TANKS BOOSTER PUMP STATION DATE DATE : DRAFTERREVISIONS RECORD/DESCRIPTION UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW. C.T. MALE ASSOCIATES DRAFTED CHECKED SCALE : PROJ. NO CHECK APPR. : : : : c DWG. NO: SHEET OF PROJECT NUMBER: www.ctmale.com C.T. MALE ASSOCIATES Engineering, Surveying, Architecture, Landscape Architecture & Geology, D.P.C. 50 CENTURY HILL DRIVE, LATHAM, NY 12110 PH: 518.786.7400 GLENS FALLS, NY · JOHNSTOWN, NY · POUGHKEEPSIE, NY · SYRACUSE, NY 25.0998 REGENERON MASTER PLAN 56 DUPLAINVILLE ROAD CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORK 2026 25.0998 DEC. 16, 2025 1 18-____ 1 2 3 4 5 6 7 8 9CA D D W G . F I L E N A M E : DESIGNED XREFS: K: \ P r o j e c t s \ 2 5 0 9 9 8 \ C i v i l \ D r a w i n g s - M a p s \ O v e r a l l S k e t c h P l a n - S E Q R A m a p \ R e g e n o v e r a l l S K . d w g Re g e n o v e r a l l S K . d w g OVERALL DEVELOPMENT SCHEMATIC PLAN KCS 1"=60' OVERALL SK 1 NONE MAC KCS FI L E N A M E 3/9/26 REVISED PER PB REVIEW MAC KCS KCS 4/15/26 ADDED POTABLE WATER TANKS MAC KCS KCS ====== E E E E PROPOSED PARKING GARAGE DUPLAINVILLE R O A D ADAMS ROAD M A R S E L D R I V E PREVIOUSLY APPROVED BUILDING ADDITION DW D W D W W W W W W W W W W W W W 9 5 . 5 ' ± 4 9 . 9 ' ± 409.2'± 198.2'± 5 0 . 1 ' ± 40' FRONT SET B A C K 1 5 ' S I D E S E T B A C K 1 5 ' S I D E S E T B A C K 30' REAR SETB A C K EXISTING PRINCIPAL BUILDING PROPERTY BO U N D A R Y PROPERTY BO U N D A R Y 136.5'± 9 3 . 1 ' ± FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM F M F M F M F M F M F M F M F M F M F M FM F M F M F M FM FM FM DATE DATE : DRAFTERREVISIONS RECORD/DESCRIPTION UNAUTHORIZED ALTERATION OR ADDITION TO THIS DOCUMENT IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW. C.T. MALE ASSOCIATES DRAFTED CHECKED SCALE : PROJ. NO CHECK APPR. : : : : c DWG. NO: SHEET OF PROJECT NUMBER: www.ctmale.com C.T. MALE ASSOCIATES Engineering, Surveying, Architecture, Landscape Architecture & Geology, D.P.C. 50 CENTURY HILL DRIVE, LATHAM, NY 12110 PH: 518.786.7400 GLENS FALLS, NY · JOHNSTOWN, NY · POUGHKEEPSIE, NY · SYRACUSE, NY 25.0998 REGENERON MASTER PLAN 56 DUPLAINVILLE ROAD CITY OF SARATOGA SPRINGS SARATOGA COUNTY, NEW YORK 2026 25.0998 DEC. 16, 2025 1 18-____ 1 2 3 4 5 6 7 8 9CA D D W G . F I L E N A M E : DESIGNED XREFS: K: \ P r o j e c t s \ 2 5 0 9 9 8 \ C i v i l \ D r a w i n g s - M a p s \ O v e r a l l S k e t c h P l a n - S E Q R A m a p \ R e g e n o v e r a l l Z o n i n g . d w g Re g e n o v e r a l l Z o n i n g . d w g OVERALL ZONING REVIEW KCS 1"=60' OVERALL SK 1 NONE MAC KCS FI L E N A M E SITE STATISTICS ZONE: INDUSTRIAL GENERAL (IND-G) REQUIRED EXISTING PROPOSED MIN. LOT AREA 40,000± SF 2,704,965±SF (OR 62.1 ACRES) 2,704,965±SF (OR 62.1 ACRES) MIN. LOT WIDTH 200 FEET 1,734 FEET 1,734 FEET BUILDING HEIGHT 50 FEET 32'-6" ¹49'-6" ² BUILDING AREA ¹N/A 907,574 SF (33.5%)986,871 SF (36.5%)** IMPERVIOUS AREA (ASPHALT, CONCRETE, OTHER BDGS) N/A 873,326 SF (32.3%)824,890 SF (30.3%) GREENSPACE 30%924,065 SF (34.2%)893,204 SF (33.2%) MAX. IMPERVIOUS SURFACE COVERAGE 70%1,780,900 (65.8%)1,811,761 (66.8%)** MIN. FRONT YARD SETBACK ¹40 FEET 95.5± FEET (ADAMS ROAD) 93.1± FEET** (ADAMS ROAD) MIN. SIDE YARD SETBACK ¹15 FEET 198.2± FEET 198.2± FEET MIN. REAR YARD SETBACK ¹30 FEET 49.9± FEET (DUPLAINVILLE RD) 49.9± FEET (DUPLAINVILLE RD) PARKING 419 SPACES REQ.839 SPACES 1,493 SPACES*** ¹FROM PRINCIPAL BUILDING ²FROM PARKING GARAGE ** INCLUDES FUTURE BUILDING M (ALREADY APPROVED - THEN KNOWN AS BUILDING 8) *** INCLUDES FUTURE PARKING GARAGE (UP TO 1,000 SPACES) PARKING ANALYSIS INDUSTRIAL GENERAL PARKING REQUIREMENTS: 1 PER 1,000 SF GFA UP TO 40,000 SF, THEN 1 PER 2,500 SF FOR ADDITIONAL GFA ABOVE 40,000 SF (EXCLUDING OUTDOOR STORAGE) OVERALL TOTAL PRINCIPAL BUILDING AREA= 986,871 SF 986,871 - 40,000 = 946,871 40,000 / 1000 = 40 SPACES 946,871 / 2,500 = 379 SPACES 379 + 40 = TOTAL 419 SPACES REQUIRED PROPOSED DEVELOPMENT NEEDS: REGENERON ANTICIPATES TO EMPLOY UP TO 1,000 WORKERS IN THE FUTURE. THEREFORE A FUTURE PARKING GARAGE IS SHOWN THAT WOULD ALLOW UP TO 1,000 PARKING SPACES. BRINGING THE TOTAL AVAILABLE PARKING TO 1,493 SPACES IN THE FUTURE. 3/9/26 REVISED PER PB REVIEW MAC KCS KCS 4/15/26 ADDED POTABLE WATER TANKS MAC KCS KCS