Loading...
HomeMy WebLinkAbout20260264 4 Schuyler Dr Equipment Install - Solar Application"HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED" CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD JMO�'� CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* Name Lane Vincent Address 4 Schuyler Dr. Saratoga Springs, NY 12866 OWNER(S) (lfnotapplicant} Phone (518) 221-2�55 / Email Ianevincent@yahoo.com Identify primary contact person: ❑ Applicant ED Owner ❑ Attorney/Agent fFOR OFFICE USEI (Application #) (Date received) (Project Title) Staff Review ATTORNEY/AGENT * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: PROPERTY INFORMATION 8 Owner ❑ Lessee Property Address/Location: 4 Schuyler Dr. Saratoga Springs, NY 12866 Date Acquired by Owner: Current Zoning District: U R 1 ❑ Under option to lease or purchase Tax Parcel #: 166 14 1 2 (for example: /65.52 - 4 - 37) Property use: 19 Residential ❑ Non-residential/mixed-use Type of Review: 0 Architectural ❑ Historic ❑ Extension/modification (of current approval) Summary description of proposed action: New install of a 6.44kW roof mounted solar array. 14 REC 460W panels w/ Enphase micro inverters. Re Roof of 18 sauares. Has a previous application been filed with the DRB for this property? Revised 12/2025 e No ❑ Yes - date(s)? - App. No.(s)? **A "complete" application consists of 1 hard copy (originaD , and I electronic copy of application &ALL other materials as required below: New Construction / Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17x11 " sheet. ❑ Elevation drawings showing design of all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Floor plans for proposed structure; on sheet no larger than 2'x3'— smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Within front yard setbacks In Historic Districts onlX (Front setbacks: UR-I & INST-HTR=30'; UR-4=25'; UR-2, UR-3 & NCUD-1=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2'x3' sheet — smaller preferred if legible ❑ Product literature, specifications and samples of proposed materials and colors Signage / Awnings 0 Color photographs showing site/exterior details of existing structures, and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I "x 17" ❑ Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location ❑ Product literature, specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of "architectural/historical significance", demonstrate "good cause" why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing" structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale ❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 12/2025 Request for extension of current approval ❑ Identify date of original DRB approval: Current expiration date: Org. App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form ❑ Applicants proposing the following must complete "Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.nX.gov/docs/permits ej operations pdf/seafpartone.pdf): - Construction or expansion of a multi -family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? iNo ❑ Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Board. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Board and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural R iew of the Zoning Code of the City of Saratoga Springs. �,goe Date: 2/25/2026 (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: 4 1/,'� Date: 2/25/2026 Owner Signature: Date: Revised 12/2025 ��.` CITY OF SARATOGA SPRINGS DESIGN REVIEW BOARD City Hall - 474 Broadway Saratoga Springs, New York 12866 •/^/C�RPORATE0 Tel: 518-587-3550 x2533 www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/ HISTORIC REVIEW APPLICATION 1. ELIGIBILITY: An applicant to the Design Review Board for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRB will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit • Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure • any material change to exterior of a structure including: • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior Within a non-residential zoning district: building elements such as roof, siding, windows, doors, • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. ■ Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note — Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. Revised 12/2025 4. DESIGN GUIDELINES: The Design Review Board will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height — consistent with historic form and context of site and surrounding properties • Scale — relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front facade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other fagade elements • Directional Expression — compatibility with horizontal & vertical expression of surrounding structures • Massing & Open Space — relationship of structure to open space between it and adjoining buildings • Setback — compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Building materials - Color — (in non-residential zoning districts only) 5. DECISIONS: The Design Review Board may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/ quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first -come, first -served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Board responsibilities may be found in the City's Unified Development Ordinance available in City Hall and on the City's web site at https://ny-saratogasprings.civicplus.com/DocurnentCenterl View/17803/Full-UDO Revised 12/2025 City of Saratoga Springs OFFICE OF PLANNING AND ECONOMIC DEVELOPMENT FEES - 2026 Application to City Council FEE Comprehensive Plan Amendment $1,800 + $300/acre Zoning Ordinance Amendment $800 + $300/acre Planned Unit Development (PUD) Amendment $800 + $300/acre Application to Zoning Board of Appeals FEE Use Variance $1,400 + $75/app Area Variance - Residential (1 & 2 Family) $350/1 st var + $75/app + $150/ea add variance Area Variance - 3+ Family and Commercial $1,000/1st var+$75/app + $200/ea add variance Interpretations $650 + $75/app Post Work Application Fee Application Fee x2 + $75/app Variance Extensions 50% of Application Fee + $75/app Demolition $500 Residential Structures — 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $75 Fagade Change - removal/addition of windows, doors, porch $150 Addition or new construction $300 Approval Extension 50% of Application Fee 3+/Multi-Family, Comm. Mixed -Use Principal or Accessory Structure Equipment Install or Materials Change - roof, windows, siding, paint color $150 Signs, awnings $150 Fagade Change - removal/addition of windows, doors, porch $300 Addition or new construction $650 Approval Extension or Modification 50% of Application Fee Post Work Application Fee Application x2 Jpecial use Hermit $1,200+$75/app Temporary Use Permit $500 Special Use Permit - Extension $400 Special Use Permit - Modification $550 + $75/app Site Plan Review - incl. PUD Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non -Residential / Mixed -use $800 + $150/1,000 sf (Non -Res) +250 unit (Res) Administrative SPR Residential $400 Non -Residential / Mixed -use $800 Extension Residential $250 Non -Residential / Mixed -use $350 Subdivision - incl. PUD Sketch Plan $400 per sketch Preliminary Approval Residential: 1-5 Lots $700 + $75/app Residential: 6-10 Lots $1,100 + $75/app Residential: 11-20 Lots $1,450 +$75/app Residential: 21+ Lots $1,800 +$75/app Residential - Extension $350 Final Approval Residential $1,550 + $200/lot + $75/app Non -Residential $2,400/lot + $75/app Final Approval Modification Residential $400 + $75/app Non -Residential $800 + $75/app Final Approval Extension Residential $250 Non -Residential $350 Subdivisions and Site Plans are subject to Engineering Review- See DPW Fees Lot Line Adjustment/Subdivision Administrative Action Letter of Credit — Modification Extension Letter of Credit - Collection Recreation Fee Land Disturbance Activity Permit Watercourse/Wetland Permit Watercourse/Wetland Permit Extension SEQRA EIS Review (Draft & Final) Sidewalk Fee Lieu Tree Removal $400 $400 up to 1 % of LoC $2,000/lot or unit $750 + $35/acre $750 $350 TBD See DPW Fees Avg. nursery cost in caliper of new species equivalent to diameter at breat height (DBH of tree(s) Removed Short Environmental Assessment Form Part I - Project Information Instructions for Completing Part 1— Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part 1— Project and Sponsor Information Name of Action or Project: Roof Mounted Solar Panels & Re Roof Project Location (describe, and attach a location map): 4 Schuyler Dr. Saratoga Springs, NY 12866 Brief Description of Proposed Action: New electrical installation for a 6.44kW roof mounted solar array. 14 REC 460W Panels w/ 14 Enphase micro inverters. Re Roof of 18 squares Name of Applicant or Sponsor: Telephone: (845) 317-8019 Courtney Roberts E-Mail: permits@empiresolarny.com Address: 2-8 Johnes St. City/PO: tate: TNy Zip Code: Newburgh 12550 1. Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, NO YES administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that El be affected in the municipality and proceed to Part 2. If no, continue to question 2. 2. Does the proposed action require a permit, approval or funding from any other government Agency? NO YES If Yes, list agency(s) name and permit or approval: ❑ 3. a. Total acreage of the site of the proposed action? 0.0072 acres b. Total acreage to be physically disturbed? 0 acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor? 0 acres 4. Check all land uses that occur on, are adjoining or near the proposed action: 5. ❑ Urban ❑ Rural (non -agriculture) ❑ Industrial ❑ Commercial m Residential (suburban) ❑ Forest ❑ Agriculture ❑ Aquatic 0 Other(Specify): ❑ Parkland Page 1 of 3 5. Is the proposed action, a. A permitted use under the zoning regulations? b. Consistent with the adopted comprehensive plan? NO YES N/A ❑ ❑✓ ❑✓ ❑ ❑ ❑ 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? NO YES ❑✓ ❑ 7. Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? If Yes, identify: NO YES ❑✓ ❑ 8. a. Will the proposed action result in a substantial increase in traffic above present levels? b. Are public transportation services available at or near the site of the proposed action? c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed acti on? NO YES ❑✓ ❑ ❑ ❑ ❑ ❑ 9. Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: NO YES ❑ ❑✓ 10. Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable water: NO YES 11. Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: NO YES ❑✓ ❑ 12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district which is listed on the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory? NO YES ❑ ❑ 13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? b. Would the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: NO YES Z El- ❑ ❑ Page 2 of 3 14. Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply: ❑Shoreline ❑ Forest ❑ Agricultural/grasslands ❑ Early mid -successional ❑ Wetland m Urban ❑ Suburban 15. Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or Federal government as threatened or endangered? NO YES ❑ ❑ 16. Is the project site located in the 100-year flood plan? NO YES 7 ❑ 17. Will the proposed action create storm water discharge, either from point or non -point sources? If Yes, a. Will storm water discharges flow to adjacent properties? b. Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: NO YES 17 ❑ ❑ 18. Does the proposed action include construction or other activities that would result in the impoundment of water or other liquids (e.g., retention pond, waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment: NO YES ❑ ❑ 19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste management facility? If Yes, describe: NO YES 20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or completed) for hazardous waste? If Yes, describe: NO YES I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Applicant/sponsor/name:Courtney Roberts Date: 3/12/2026 Signature: I""ns- Title: Operations Manager PRINT FORM I Page 3 of 3 EAF Mapper Summary Report Thursday, March 12, 2026 3:51 PM Disclaimer: The EAF Mapper is a screening tool intended to assist `— . project sponsors and reviewing agencies in preparing an environmental ......... assessment form (EAF). Not all questions asked in the EAF are _ answered by the EAF Mapper. Additional information on any EAF question can be obtained by consulting the EAF Workbooks. Although -16 , 14--2=l the EAF Mapper provides the most up-to-date digital data available to II DEC, you may also need to contact local or other data sources to 1 confirm data provided by the Mapper or to obtain data not provided by I 166. -14-1-1 11 the Mapper. I 'I !iV.'1-1�-2--1 Kin ri,1— �ianipzl Saratoga SOngS Toronto 'I166.14-1-2 6r:.'I3-'I-'I'I _— — � Ft.,m�irno Ctl _ _ 1 I 4I 66A4-2-74 I Y 'I 16:•'I E'I 3 1 E.I -iE-=,li I__ lirei ,, ,rttrir. E I-1�r�s l,__'I-wl: If,r F.C'.'C'11 C- f'h:;.[,• Es•t!.I I l P_l Es 1 .I A-m -1 A' _ _ l I'1�='I'1-1' t '�1'fL E°.rl is ;,lp' FSir I-A1191'-il I'•I�—pri,`_jtr'?l%l, '11 fr1"tl l.';��.5', rC:— ', t� —� 9"i.^ ,I — I' ; —r 1 I II! II 1 •_1= 1Js_ r_'r r .I t, I 1 t EA HI : G' t - Prll.iurtnl. Part 1 / Question 7 [Critical Environmental ,Area] Part 1 / Question 12a [National or State Register of Historic Places or State Eligible Sites] Part 1 / Question 12b [Archeological Sites] Part 1 / Question 13a [Wetlands or Other Regulated Waterbodies] Part 1 / Question 15 [Threatened or Endangered Animal] Part 1 / Question 16 [100 Year Flood Plain] Part 1 / Question 20 [Remediation Site] No Yes No Digital mapping data are not available or are incomplete. Refer to EAF Workbook. No Digital mapping data are not available or are incomplete. Refer to EAF Workbook. No Short Environmental Assessment Form - EAF Mapper Summary Report 1 Pi 4 `a,4 AW ai;x�?:Stz �� ,. " � - � 1. � _• I -' �"':gy � � a —..r � � � �'. �,�_ _� � G � � _ {� f'�f�5.�-... .� A.<., �, ;,� `� �'r'' �4� l" 1 Vincent Residence 4 Schuyler Dr. Saratoga Springs, NY 12866 i;4 View of House from the Intersection of Schuyler Dr. & Lake Ave. Tl:i: i ass Y' r.. . � A - • * �� - 1 •�.`xr.4, a ':� ,,'r , j • �V + '�, � }e rw.-y. �,-•r�r�a.�.,.r.••---Ya,�? 16 _Ile • .Y! lop �. 4 4 Vincent Residence 4 Schuyler Dr. Saratoga Springs, NY 12866 3D Rendering of Panels — Back of House Vincent Residence 4 Schuyler Dr. Saratoga Springs, NY 12866 31) Rendering of Panels — Aerial View of Neighborhood ROOF PANEL LAYOUT PLAN: N TS SITE VERIFICATION NOTES: 1. PRIOR TO SUBMISSION TO MUNICIPALITY OF THE PLANS, THIS CONTRACTOR SHALL VISIT THE JOB SITE TO ASCERTAIN THE ACTUAL FIELD CONDITIONS AS THEY RELATE TO THE WORK INDICATED ON THE DRAWINGS AND DESCRIBED HEREIN. DISCREPANCIES, IF ANY, SHALL BE BROUGHT TO THE ENGINEER'S ATTEN11ON PRIOR TO SUBMISSION OF THE PLANS. SUBMISSION OF PLANS SHALL BE EVIDENCE THAT SITE VERIFICATION HAS BEEN PERFORMED AS DESCRIBED ABOVE. 2. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF WORK. IF EXISTING CONDITIONS VARY FROM PLANS, THE CONTRACTOR SHALL STOP WORK AND NOTIFY PROJECT ENGINEER A.S.A.P. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND LIABILITY THEREFROM. 3_ THE OWNER/CONTRATOR SHALL OBTAIN ALL NECESSARY PERMITS, VERIFY ALL CONDITIONS, EXAMINE THE DESIGN DOCUMENTS AND BE RESPONSIBLE FOR ALL MEASUREMENTS, DIMENSIONS AND CONDITIONS. 4. COMMENCEMENT OF CONSTRUCTION WILL SIGNIFY THAT THE CONTRACTOR WILL HOLD THE DESIGN ENGINEER HARMLESS FOR ANY AND ALL ERRORS, OMISSIONS AND PERSONAL LIABILITY. E M P I R Ersj�t�:1�. NORTH METER, COMBINER & MAIN DISCONNECT SOLAR ARRAY #1 14 REC 460W PV PANELS SEE SHEET 2 OF 5 FOR PANEL LAYOUT SOLARPANEL REVISIONS NOTES INSTALLATION VINCENT RESIDENCE DWG. BY: MEM CHECKED BY: MEM 4 SCHUYLER DR. DATE: DECEMBER 10, 2025 SARATOGA SPRINGS, NY MUNICIPALITY: 12866 - USA I CITY OF SARATOGA SPRINGS n n o c O St Clements O x n " 6 Sar, toga 1 inrse Shw T _ N a ^. a 70 v r> A O O C- O 0 0 Sarotoga-Villton V Youth Baseball n o v o East Side C] p o o n Recreation 9 Parr, Green Rircr Pictures . 6 y o G s AERIAL MAP: N TS PROJECT DESIGN DATA. - WORK SHALL BE COMPLETED AS PER 2020 RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019, NFPA 70, 2020 NATIONAL ELECTRICAL CODE AND 2018 WOOD FRAME CONSTRUCTION MANUEL LOAD CRITERIA AS FOLLOWS EXPOSURE CATEGORY: "B" GROUND SNOW LOAD: 50 PSF WIND SPEED: 120 MPH GENERAL NOTES: 1. ALL SOLAR MODULES TO BE REC 46OW AND SHALL BE INSTALLED AS PER REC INSTALLATION MANUAL. 2. ALL INVERTERS TO BE ENPHASE MICRO INVERTERS ALL RACKING TO BE IRON RIDGE AND ALL RACKING TO INSTALLED AS PER IRON RIDGE MANUFACTURERS SPECIFICATIONS. RESIDENTIAL SOLAR PANEL INSTALLATION LOCATED AT - 4 SCHUYLER DR. SARATOGA SPRINGS, NY 12866 CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, NEW YORK SYSTEM NOTES: TOTAL SYSTEM SIZE: 6.44KW DC SYSTEM / 5.32KW AC SYSTEM PANEL TYPE: REC 46OW �— OF PANELS: 14 AS -NOTED INVERTER TYPE: ENPHASE IQBX ES-4392.25 OF INVERTERS: 14 SOL#: 166.14-1-2 ARRAY #1 AZIMUTH: 263 COUNTY: TILT. 20 SARATOGA #PANELS 14 SCALE: PROJECT #: PROFESSIONAL NOTES: UNAUTHORIZED ALTERATION OR ADDITION TO THIS PLAN IS A VIOLATION OF SECTION 7209(2) OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS MAP NOT HAVING THE SEAL OF THE ENGINEER SHALL NOT BE VALID SEAL & SIGNATURE (�OF NEW Y EDWg9o'0�� r✓ j m o ,' Z 079676. '* \ `gOFESSIONP DWG# S-1 PROJECT SITE PLAN AND NOTES DWG. 1 OF 5 FIRST RESPONDER ACCESS AS PER THE 2020 _ RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019, SECTION R324.6 "ROOF ACCESS AND PATHWAYS" ROOF PANEL LAYOUT: ONT OF HOUSE PROPOSED ARRAY #1 (14) REC 460W SOLAR MODULES MOUNTED PORTRAIT CONFIGURATION ON IRON RIDGE RACKING AS PER IRON RIDGE INSTALLATION MANUAL PROFESSIONAL NOTES: NOTES SYSTEM NOTES: SEAL SIGNATURE SOLAR PANEL TOTAL SYSTEM SIZE: UNAUTHORIZED ALTERATION OF NEw INSTALLATION 6.44KW DC SYSTEM / 5.32KW AC SYSTEM PEE EDWq �o OR ADDITION TO THIS PLAN PANEL TYPE: REC 46OW IS A VIOLA-PON OF SECTION co <,\- h'O 9� VINCENT 7209(2) OF THE NEW YORK OF PANELS: 14 RESIDENCE 1j Dwo. Br: MEM scA�E: AS•NOTED STATE EDUCATION LAW. ? , M - , _ t x;� ',`:ten , �' INVERTFJ2 TYPE: ENPHASE IQBX I I '. EMPIRE _i COPIES OF THIS MAP NOT w PROJECT#: ES•4392.25 - CHECKEDBY: MEM OF INVERTERS: 14 HAVING THE SEAL OF THE �, z 4 SCHUYLER DR. ENGINEER SHALL NOT BE J' DATE: DECEMBER 10, 2025 see#' 166.14.1.2 ARRAY #1 VALID �4A .,07967'0 SARATOGA SPRINGS, NY muNiCiPAUTY: couNTY: AZIMUTH; 20 90FESS101 P 12866 - USA CITY OF SARATOGA SPRINGS SARATOGA #PANELS 14 DWG# S-2 SOLAR ROOF LAYOUT PLAN DWG 2OF5 IRON RIDGE RACKING Viind Speed Exposure (mph} 0 psf Snow Zane Z"- Zane 1 2 :1 10 psf SneW Zone Zone Zone 1 2 3 20 psf Snow Zone Zane Zone 1 2 3 30 psf Snow Zove Zane Zona 1 2 3 40 psf Snow Zcne Zone Zme 1 40 mph 13.5 135 i0.5 12.5 12.5 10.5 10.5 10.5 10.5 i0.0 10.0 10.0 9.0 9.0 9.0 100 mph 13.5 12.0 9.5 12.5 2.0 9.5 10.5 10.5 9.5 10.0 10.0 9.5 9.0 9.0 Ail 110 mph 13.5 11.5 9.0 12.5 11.5 9.0 =0.5 10.5 9.0 10.0 10.0 9.0 9.0 9.0 9.0 Ca6egory B 120 mph 13.5 10.5 0.5 12.5 10.5 9.5 10.5 111.5 0.5 10.t1 10.0 8.5 9.0 9.0 8,5 130 mph 13.5 9.5 7.5 12.5 9.5 7.5 10.5 9.5 75 10_(1 11.5 7.5 9.0 9.0 7.5 110 mph 12.5 9.0 7.0 12.5 9.0 7.0 10.5 9.0 7.0 10.0 9.0 7.0 9.0 9.0 7.0 150 mph 11.5 8.5 6.5 11..5 8.5 6.5 1 9.5 9.5 9.5 10.0 8.5 0..5 9.0 8.5 6,5 90 mph 13.5 11.0 6.5 12.5 11.0 8.5 10.5 10.5 10.5 10.0 10.0 &5 9.0 9.0 8.5 i00 mph 13.5 9.5 6.0 12.5 9.5 8.0 10.5 9.5 8.0 10.0 9.5 8.0 9.10 9.0 as 110 mph 13.0 9.5 7.5 12.5 9.5 7.5 10.5 9.5 7.5 10.0 9.5 7.5 9.0 9.0 7.5 Category C 120 mph 12.0 8.5 7.0 12.0 0.5 7.0 30.5 0.5 7.0 10.0 8.5 7.0 9.0 B.5 70 130 mph 11.0 6.4 5.5 11.0 0.0 -5.5 IO.5 8.0 f1.5 95 8.0 6.5 9.0 6.0 &5 i40 mph 10.0 7.5 6.0 10.0 7.5 &0 10.0 7.5 6.0 9.5 7.5 6.0 8.5 7.5 60 150 mph 1 9.5 7.0 5.51 R,5 7.0 5.51 9.5 7.0 5.51 9.0 7.0 5.51 8.5 7.0 5.5 14 REC 460W SOLAR PANELS MODULES MOUNTED PORTRAIT 2X12 RIDGE BEAM CONFIGURATION ON IRON RIDGE RAILS, INSTALL AS PER DETAIL ASPHALT SINGLES (ONE LAYER) AND IRON RIDGE INSTALLATION MANUAL PLYWOOD SHEATHING ANCHOR POINTS @ 48" 2X8 WOOD FRAMING MAX SPASEIENG DETZ O 16" O.C. ROOF SECTION: NTS REC 46OW SOLAR PANEL MODULE "L" BRACKET SPACED 48" O.C. MAX 3-1/2" EFFECTIVE THREAD LENGTH RAFTER PENETRATION (MIN.) IRON RIDGE RAIL, INSTALL AS PER IRON RIDGE INSTALLATION MANUAL ROOFING SEALANT ALL AROUND ASPHALT SHINGLES 6" MAX. OFF ROOF SURFACE 4"Xi" STAINLESS STEEL LAG BOLTS ATTACHMENT DETAIL: NTS REVISIONS NOTES SYSTEM NOTES: PROFESSIONAL NOTES: SEAL & SIGNATURE DWG# SOLAR PANEL TOTAL SYSTEM SIZE: UNAUTHORIZED ALTERATION OF NEW ' S-3 6.4MCW DC SYSTEM / 5.32KW AC SYSTEM OR ADDITION TO THIS PLAN Y INSTALLATION PANEL TYPE: REC 46OW IS A VIOLATION OF SECTION �QP��EOWg90 �9� SOLAR \/ 7209 2 OF THE NEW YORK � Y I CENT OF PANELS: 14 (� �* PANEL r F 1 1 nWG. BY: MEM SCALE: AS•NOTED STATE EDUCATION LAW. I s EMPIRE'.-Y'-) , M, �� RESIDENCE INVERTER TYPE ENPHASE IQBX COPIES OF THIS MAP NOT F:j �W '"'� CHECKED BY: MEM PROJECT ES•4392.25 HAVING THE SEAL OF THE 2 ATTACHMENT OF INVERTERS: 14 4 SCHUYLER DR. ENGINEER SHALL NOT BE DATE: DECEMBER 10, 2025 SBL#: 166.14.1.2 ARRAY VALID �a 06 .- PLAN SARATOGA SPRINGS, NY AZIMUTH: 267961 3 A9 SSIO '. - 0:'.- owe. MUNICIPALITY: COUNTY: TILT: 2O �.0�`-: 12866 -USA CITY OF SARATOGA SPRINGS SARATOGA # PANELS 14 =- 3 O F CERTIFICATION NOTES: THE ROOF STRUCTURAL MEMBERS HAVE BEEN CHECKED FOR 120 MPH WIND LOADS BASED ON ASCE7-16 AND FOR COMPLIANCE WITH THE 2020 RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019. THERE WAS (1) LAYER OF ROOF SHINGLES INSTALLED AT THE TIME OF THE INSPECTION. THIS PLAN DOES NOT APPLY IF ANY ADDITIONAL ROOF SHINGLES LAYERS ARE INSTALLED AFTER THE SITE INSPECTION. INSTALLATION OF SOLAR PANELS WITH MORE THAN (1) LAYERS OF ROOF SHINGLES IS NEVER PERMITTED. 2- THE MOUNTING BRACKETS & HARDWARE MEET OR EXCEEDS ASCE 7-16 AND 2020 RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019 WITH 120 MPH WIND DESIGN. THE SYSTEM'S ATTACHMENT TO THE ROOF TO MEET OR EXCEED 2020 RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019. 3.ANY PLUMBING VENTS THROUGH THE ROOF ARE NOT TO BE CUT OR COVERED DURING PANEL INSTALLATION. ANY MODIFICATION OR RELOCATION OF VENTS WILL REQUIRED A PLUMBING PERMIT AND INSPECTIONS. 4. SIZES OF MEMBERS THAT WERE NOT ACCESSIBLE FOR DIRECT MEASUREMENT ARE BASED ON OBSERVATIONS OF ACCESSIBLE MEMBERS OR CONSTRUCTION DEPTH OR BOTH AND OUR KNOWLEDGE OF STANDARD CONSTRUCTION PRACTICES AT THE TIME OF CONSTRUCTION. 5. THE EXISTING ROOF AND BUILDING STRUCTURE CAN SAFELY SUSTAIN, AND DISTRIBUTE TO THE GROUND, THE ADDITIONAL LOADS IMPOSED BY THE PROPOSED WORK IN ADDITION TO ALL OTHER GRAVITY AND LATERAL LOADS AS REQUIRED BY 2020 RESIDENTIAL CODE OF NEW YORK STATE, PUBLICATION DATE: NOVEMBER 2019 E MP I R E "D ('21, 1.- A I GENERALDATA Cell type: 88 half -cut bifacial REC heterojunction cells } with lead-free, gapless technology I Glass: 0.12 in solar glass with anti -re nectwe surface treatment in a ccerdance wi I h E N 12150 Backsheet: Highly resistant polymer Framc: Anodized aluminum (61ack) Junction box 4-part, 4 bypass diodes, lead-free IP68rared. In accordance with IEC62790 j Connectors: 5thubli MC4 PV-KBT4/KST4 (12 AWG) In accorda nc, wi lh IEC 62652. IP60 o my when ce nnec tod Cable: 12 AWG solar cable,66.9. 66.91n In accordance with EN 50618 D 680 481 12' 224 h Imenslons. x x In( . sq- r. Weight: 6lb � Origin: Made m Singe t Measurementsi inches ELECTRICALDATA Product Code': RECxxxAA Pure-RX CERTIFICATIONS PowerOutput-P,„x(Wp) 450 460 470 IEC 61215:2021, 1EC617302016,1.11 61730 Watt Class Sorting -(W) 0/.10 0/+10 0/i10 IEC 62804 PID IEC61701 Salt Mist Neminal Power Voltage -V„m(V) 54.3 54.9 55A IEC62716 Ammonia Resistance u Nominal Power Current- L,;,,(A) 8.29 8.38 8.49 15011925-2 ignitability(EN 13501-1 Class E) 1A Open Circuit Voltagee-Voc IV) 65.1 653 656 IEC 62782 Dynamic Mechanical Load IEC61215-2:2016 Hailstari,05mm) Short Circuit Current - Isc(A) 8.81 8.88 8.9S IEC62321 Lead-freeacc. to RoHS EU 863/2015 Power Density(W/sq-R) 20.1 20.5 21.0 U1-61730 FireType2 Panel Efficiency(%} 21.6 22.1 22.6 ISO 14001, 1509001, IEC 45001, IEC 62941 Power Output -P_(WP) 343 - 350--- _ -358--- °Ve -O' C E I tt Nominal Power Voltage-V,,,,IV) 51.2 51.7 52.2 eaaav a.wn.ae,- NominalPowerCurrent -I (A) 670 677 686 o Declare. = Open Circuit Voltage - Vac(V) 61.3 61.6 61.8 Short Circuit Current -Lr(A) 7.11 7.17 7.23 Values at standard lestcond,u... (STC air,,ss AM l.5.Irradiance 1000VI/,, ,temperature 7TF(2ST)L based ona,reduction spread w'thalcl,mnc,,na, V�: &L.z3% wthin one watt class. Nominal medal, operating tamperalur,(N.MOT. air mass AM l.S, irradiance 800 W/mr, temperature fib°F ILO'C). windspeed 3.3 ft/s (I m/s)),"lVhera xxx indicates thenominal power lass (P.,.�)at STC above. MAXIMUM RATINGS WARRANTY Operational temperature: -40....185-F Standard RECProTrust Systemvoltage: 1000V Installedbyan REC No Yes Yes CertlfiedlSolarPrefessional Test load (front); +7000 Pa(146.21bs/sq-ft) System Size All c25 kW 25-500 kW Testload(rear): -4000 Pit (83.516s/sq-ft)* Product Warranty(yrs) 20 25 25 Series fuse rating: 25A Power Warranty(yrs) 25 25 25 Reverse current: 25A Labor Warranty(yrs) 0 25 10 'See lnstallalion manual I.,cr-Im in,nuctip Power in Year 98% 98% 98% Design load- Test mad/ I.5 arty factor) Annual Degradation 0.25% 0.25% 025% Powerm Year25 92% 92% 92% Th, REC Pr,Tr..tV1,rranlyisonly availa bleon pants purchased rare cgh as REC Ccrtiecdselar p,.he 'tonal Insiullcr.warranty anI Thins ap,ly.see wrnr.recgroup.com for more details. Available from: Founded 1n 1996, REC Group Is an international pioneering solar energycompany dedicated to empowering consumeis with clean, affordable solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the selar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs m North America, Europe, and Asia -Pacific. SOLARPANEL I REVISIONS NOTES INSTALLATION VINCENT RESIDENCE 4 SCHUYLER DR. SARATOGA SPRINGS, NY 12866 - USA TEMPERATURE RATINGS* Nominal Module OperatingTemperature, 44-C(±2-C) Temperature coefficient of P..:-0.24%/°K Temperaturecoii ient ofVpc: -0.24%/°K Temperature coefficient of Isc: 0.04 %/°K ThetemperalurecoeKclentsstatedarelinearvalues DELIVERY INFORMATION PanelsperpalleC 33 Panels per 40 It GP/high cube container: 594 (I8 pallets) Panel5per53 ft truck- 792(24pallets) LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: is to a RECSoIar PTE.LTO. e.�^ 20Tuas South Ave.14 REC Singapore637312 post@recgroup.com wwwrecgroup.com DWG. BY: MEM I SCALE: AS -NOTED CHECKED BY: MEM I PROJECT #: ES-4392-25 DATE: DECEMBER 10, 2025 SOL#: 166.14-1.2 MUNICIPALITY: COUNTY: CITY OF SARATOGA SPRINGS SARATOGA IQ8X Microinverter Commonly used module pairings' Module compatibility MPPT voltage range Operating range Minimum and maximum start voltage Maximum Input DC voltage Maximum continuous operating DC current Maximum Input DC short-circuit current Maximum module IK Overvoltage class DC port DC port backfeed current PV array configuration Peak output power Maximum continuous output power Nominal grid voltage (L-U Minimum and maximum gold voltage' Max, continuous output current Nominal frequency Extended frequency range AC short circuit fault current over three cycles Maximum units per 20 A (L-U branch circuit' Total harmonic distortion Overveltage class AC port AC port backfeed current Power factor setting Grid -tied power factor (adjustable) Peakefficiancy CEC weighted efficiency Nighttime power consumption W 320-540 To meet compatibility PV modules must be within the following maximum Input DC voltage and maximum modulo ) Module compatibility can be chocked at linos://enuhase.com/installers/mi verters/calculator V 43-60 V 25-79.5 v 30-79.5 V 79.5 A 10 A 16 A 13 mA 0 Ungroundod array; no addtfonal DC side protection required; AC side protection requires maximum 20 A per branch circuit VA 384 VA 380 V 240, split-ph..(L-U, 180' v 211-264 A 1.58 Nr 60 Hx 47-68 A_" 2.70 366 360 208, single-phase (L-U, 120' 183-229 1.73 10 9 % 5 out, 18 1.0 0.65leading ... 0.85lagging % 97.3 97.0 % 96.5 96.5 raw 26 12 Ambient temperature range -40'C to 65'C (-4(Y'F to149T) Relative humidity range 4%to 100%(condensing) DC connector typo St5ubii MC4 Dimensions (H - W - D); Weight 212 ram (8.3") -175 mm (6.91- 30.2 ram (12"); 1.1 kg (2A3lbs) Cooling Natural convection -no fans Approved for wot locations; Pollution degree Yes; PD3 Enclosure Class It double -Insulated, corrosion -resistant polymeric enclosure Environmental category; UV exposure rating NEMA Type 6; outdoor COMPLIANCE CA Rule 21(UL 1741-54 UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B. ICES-0003 Class B, CAN7CSA-C22.2 NO.107.1-01 Certificatlons This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1.2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when Installed according to the manufacturer's instructlons. (0 Nc mfmced DC/AC -alb. (2) Nominal vdtege rargeun be extended beyond nominal II required M the utiFry. (3) Limits may vary. nefarta toed requirements to derma the number of mleroinvertara pm branch inyour area. (4) Jan bnol oeni6wl-muse with Enphase Three Phase Network Not tbri Rday(NPR-3P-208-NA) ant therefore designed for slrgle-pluse op .u..only. Check with the beat utility mqulrementa If you wish la instei singla phase Inverter across three prx.- 108x-MC4-DSH-OOM5-2A-EN-M-2023-11-16 SYSTEM NOTES: TOTAL SYSTEM SIZE: 6-44KW DC SYSTEM / 5.32KW AC SYSTEM PANEL TYPE: REC 46OW OF PANELS: 14 INVERTER TYPE: ENPHASE IQ8X OF INVERTERS: 14 ARRAY #1 AZIMUTH: 263 TILT: 20 # PANELS 14 PROFESSIONAL NOTES: UNAUTHORIZED ALTERATION OR ADDITION TO THIS PLAN IS A VIOLATION OF SECTION 7209(2) OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS MAP NOT HAVING THE SEAL OF THE ENGINEER SHALL NOT BE VALID SEAL & SIGNATURE OF NEB,' PP�� EDl4'A,9O OCID p. BOA 0796715 <ROFESSIONP DWG# S -4 SOLAR PANEL & INVERTER SPECIFICATIONS DWG. 4OF5 AC & DC GROUNDING CONDUCTORS PER NEC ARTICLE 690.47(C)(2) CONNECTED AS PER 250.E ALL CONDUCTORS ARE TO COPPER UNLESS NOTED 0- INVE CB1 CB2 AMPACITY: 20 AMP BREAKER AMPACITY: 20 AMP BREAKER SOLAR PANEL INSTALLATION VINCENT RESIDENCE 4 SCHUYLER DR. SARATOGA SPRINGS, NY 12866 - USA SYSTEM NOTES: TOTAL SYSTEM SIZE: 6.44KW DC SYSTEM / 5.32KW AC SYSTEM PANEL TYPE: REC 46OW OF PANELS: 14 AS -NOTED INVERTER TYPE: ENPHASE IQBX ES-4392.25 OF INVERTERS: 14 DATE: SBL #: 166.14-1.2 ARRAY DECEMBER 10, 2025 //1 AZIMUTH: 263 MUNICIPALITY: COUNTY: TILT: 20 CITY OF SARATOGA SPRINGS SARATOGA #PANELS 14 REVISIONS NOTES DWG. BY: MEM SCALE; CHECKED BY: MEM PROJECT M PROFESSIONAL NOTES: UNAUTHORIZED ALTERATION OR ADDITION TO THIS PLAN IS A VIOLATION OF SECTION 7209(2) OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS MAP NOT HAVING THE SEAL OF THE ENGINEER SHALL NOT BE VALID SEAL & SIGNATURE OF NEW EO W'q 9 y09 I ` 1, q- m '.'. Ir m 079676, ' 4e A%FESSIONP�. DWG# S-5 SOLAR PANEL 3-LINE DIAGRAM DWG. 5OF5