Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20260199 209 Nelson Ave Equipment Install - Solar Array Application
x x Helen Schwarz-Lawton 209 Nelson Ave Saratoga Springs, NY 12866 (518) 221-1006 Lakeyurt@earthlink.net 209 Nelson Ave Saratoga Springs, NY 12866 166 61 1 9 installation of 9.68kW rooftop solar array (22 panels & microinverters) x x x Plug PV LLC - Chelsea Breen 630 7th Ave Troy, NY 12182 (518) 948-5316 (838) 839-1500 permits@plugpv.com x 3/11/2026 PHOTOVOLTAIC SYSTEM AERIAL VIEW APPLICABLE CODE PER LOCAL AUTHORITY HAVING JURISDICTION APPLICABLE CODES INDEX GENERAL NOTES PV1 VICINITY MAP HELEN SCHWARZ-LAWTON: 209 NELSON AVE, SARATOGA SPRINGS, NY 12866, USA N 43.079965, -73.776518 CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB CO V E R P A G E 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A 2023 NATIONAL ELECTRICAL CODE 2020 FIRE CODE OF NYS 2025 RESIDENTIAL CODE OF NYS 2025 BUILDING CODE OF NYS GENERAL NOTES: 1.DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. 2.ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 3.IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVER-CURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 4.ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. 5.METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 6.MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6" ABOVE FLUSH VENTS. 7.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. 8.FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. 9.ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10. 10.ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. STRUCTURAL NOTES: 1.MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. 2.MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. 3.DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. ELECTRICAL NOTES: 1.ALL EQUIPMENT IS LISTED FOR USE. 2.MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. 3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. 4.AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. 5.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. 6.ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. 7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. 8.DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM. 9.MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. 10.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. 11.FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. 12.INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. 13.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 14.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. 15.BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. 16.ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. 17.ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. 18.DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. 19.ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS. 20.ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. PV1 PV2 PV3 PV4 PV5 PV6 - 6.1 COVER PAGE SITE PLAN MOUNTING PLAN MOUNTING DETAILS ELECTRICAL DIAGRAMS MARKING & LABELS *ATTACHMENTS MANUFACTURER'S SPECIFICATIONS PV7 STRUCTURAL DETAILS SYSTEM SIZE: NAMEPLATE: EQUIPMENT: PV MODULES: AC COMPONENT(S): SCOPE OF WORK: INSTALLATION OF A CODE COMPLIANT, UTILITY INTERACTIVE PHOTOVOLTAIC ELECTRIC SYSTEM. 9.68 KW DC / 7.04 KW AC MICROINVERTER:(22) ENPHASE IQ8MC-72-M-US MICROINVERTERS (22) HYUNDAI SOLAR HIS-T440NF(BK) (440W) SOLAR TYPE OF INTERCONNECTION:LINE SIDE TAP IN THE MSP (1) 60A FUSED AC DISCONNECT (1) 125A ENPHASE IQ COMBINER PANEL 5/5C 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R 14 ' - 7 " 22'-9" 11 ' - 9 " 43'-8" DRIVE W A Y NE L S O N A V E PROP E R T Y L I N E PROP E R T Y L I N E PROP E R T Y L I N E 3 ' 1' - 6 " 1'-6" 3' 1 ' - 6 " 1 ' - 6 " 3' 1'-6 " 1'-6 " PR O P E R T Y L I N E (E) UTILITY METER (OUTSIDE HOUSE) (E)MAIN SERVICE PANEL (INSIDE HOUSE) (N) AC DISCONNECT (FUSED)(OUTSIDE HOUSE) (N) COMBINER PANEL (OUTSIDE HOUSE) TALFO R D P L 18'' VENTILATION SETBACK 3' WIDE FIRE ACCESS PATHWAY MP2 MP1 MP3 MP4 N CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB SI T E P L A N 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A ARRAY 1 TILT: 31° AZIMUTH: 191° ARRAY SPECIFICATIONS ARRAY 2 TILT: 31° AZIMUTH: 101° ARRAY 3 TILT: 31° AZIMUTH: 281° ARRAY 4 TILT: 31° AZIMUTH: 11° UTILITY METER AC DISCONNECT FUSED MAIN SERVICE PANEL 3' WIDE FIRE ACCESS PATHWAY 18'' VENTILATION SETBACK 3'x3' GROUND LADDER ACCESS POINT LEGEND COMBINER PANEL PV2 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R 21' - 1 " 42'-10" 21' - 7 " 30' 5 ' - 3 " 22'-11" 10'-8" 12 ' - 2 " 1'-2" 2 1 ' - 8 " 15 ' - 2 " 15 ' - 6 " 13 ' - 9 " 39'-8" 9'-2" 8' - 5 " 1 3 ' - 2 " 14'-3" MP1 TILT:31° AZIMUTH: 191° MP2 TILT:31° AZIMUTH: 101° MP4 TILT:31° AZIMUTH: 11° MP3 TILT:31° AZIMUTH: 281° 3' WIDE FIRE ACCESS PATHWAY 18'' VENTILATION SETBACK SOLAR MODULE 2 0 ' - 8 " CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB MO U N T I N G P L A N 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A TYPE MODULE MICROINVERTER DESCRIPTION QUANTITY 22 22 1 HYUNDAI SOLAR HIS-T440NF(BK) (440W) SOLAR ENPHASE IQ8MC-72-M-US MICROINVERTER 60A FUSED AC DISCONNECTDISCONNECT 1 125A ENPHASE IQ COMBINER PANEL 5/5CCOMBINER ROOF SPECIFICATION ROOF MATERIAL ROOF CONDITION GOOD RAFTERS ASPHALT SHINGLE 2" X 8" @ 24" O.C. PV3 Design Criteria: ●Applicable Codes:2025 Residential Code of NYS, ASCE 7-22, and NDS 2024 ●Ground Snow Load:81 psf ●Basic Wind Speed:110 mph, Exposure Category B ●Existing Roof Dead Load:10.0 lb/sqft ●Existing Roof Live Load:20.0 lb/sqft 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R #14RD STRUCTURAL SCREW MIN. EMBED. 2.5" INTO ROOF FRAMING PER ATTACHMENT IRONRIDGE (XR10) RAILS IRONRIDGE (QUICK MOUNT HALO ULTRAGRIP) IRONRIDGE (QUICKMOUNT HALO ULTRAGRIP) IRONRIDGE (XR10) RAILS SOLAR MODULE WOOD SHEATHING WOOD ROOF RAFTER TYP. WOOD ROOF RAFTER TYP. WOOD SHEATHING RELEASE LINER RELEASE LINER STRUCTURAL ATTACHMENT DETAILS SOLAR MODULE CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB ST R U C T U R A L D E T A I L S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A PV4 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A MO U N T I N G D E T A I L S PV5 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R MODULES (22) HYUNDAI SOLAR HIS-T440NF(BK) (440W) SOLAR MODULES WATTS STC: 440W ISC: 14.06A IMP: 13.41A VOC: 39.90V VMP: 32.82V CONDUCTORS AND CONDUIT 41 2 (1) #6 THHN GND 3/4" EMT (1) #6 THHN GND 3/4"EMT 3 (3) #6 THHN 3/4"EMT (2) ENPHASE Q CABLES (4)#10 THHN (1) #6 THHN GND (3) #6 THHN 3/4"EMT (1) #6 THHN GND INVERTER(S) (22)ENPHASE IQ8MC-72-M-US MICROINVERTER INV OUTPUT CURRENT: 1.33 A MAX AC OUTPUT: 22X1.33 = 29.26 A INVERTER OCPD CALC :(29.26) X 1.25 = 36.58A MIN OCPD: 40A WIRE AMPACITY: 65A @75° C TERMINAL TEMPERATURE CORRECTION FACTOR: 31°-35°C = 0.96 CORRECTED WIRE AMPACITY: 62.40A OTHER EQUIPMENT (1) 60A FUSED AC DISCONNECT (1) 125A ENPHASE IQ COMBINER PANEL 5/5C G ENVOY IQ G 1 STRING OF 11 MODULES WITH MICROINVERTERS 1 STRING OF 11 MODULES WITH MICROINVERTERS 1 2 15A/2P 20A/2P 20A/2P N (N) JUNCTION BOX (N) 125A ENPHASE IQ COMBINER PANEL 5/5C (OUTSIDE HOUSE) 120/240V PANEL MAIN SERVICE FUSED DISCONNECT (N) 60A AC G 3 4 (N)40A/2P (E) 200 UM NG (E)200A GEC N A (OUTSIDE HOUSE) (INSIDE HOUSE) (E) UTILITY METER (OUTSIDE HOUSE) MAXIMUM PER STRING SIZE: 12 MICROINVERTERS CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB EL E C T R I C A L D I A G R A M S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A PV6 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D P ROFESS I O N A L E N GINEER P A U L K .ZAC H E R STRUCTURAL ONLY MODULES (22) HYUNDAI SOLAR HIS-T440NF(BK) (440W) SOLAR MODULES WATTS STC: 440W ISC: 14.06A IMP: 13.41A VOC: 39.90V VMP: 32.82V CONDUCTORS AND CONDUIT 41 2 (1) #6 THHN GND 3/4" EMT (1) #6 THHN GND 3/4"EMT 3 (3) #6 THHN 3/4"EMT (2) ENPHASE Q CABLES (4)#10 THHN (1) #6 THHN GND (3) #6 THHN 3/4"EMT (1) #6 THHN GND INVERTER(S) (22)ENPHASE IQ8MC-72-M-US MICROINVERTER INV OUTPUT CURRENT: 1.33 A MAX AC OUTPUT: 22X1.33 = 29.26 A INVERTER OCPD CALC :(29.26) X 1.25 = 36.58A MIN OCPD: 40A WIRE AMPACITY: 65A @75° C TERMINAL TEMPERATURE CORRECTION FACTOR: 31°-35°C = 0.96 CORRECTED WIRE AMPACITY: 62.40A OTHER EQUIPMENT (1) 60A FUSED AC DISCONNECT (1) 125A ENPHASE IQ COMBINER PANEL 5/5C G 1 STRING OF 11 MODULES WITH MICROINVERTERS 1 STRING OF 11 MODULES WITH MICROINVERTERS 1 2 G ENVOY IQ 15A/2P 20A/2P 20A/2P N (N) JUNCTION BOX (N) 125A ENPHASE IQ COMBINER PANEL 5/5C (OUTSIDE HOUSE) G 3 4 (N)40A/2P G N UMN GEC 120/240V PANEL MAIN SERVICE FUSED DISCONNECT (N) 60A AC (E) 200 A (OUTSIDE HOUSE) (INSIDE HOUSE) (E) UTILITY METER (OUTSIDE HOUSE)(E)200 A MAXIMUM PER STRING SIZE: 12 MICROINVERTERS CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB EL E C T R I C A L D I A G R A M S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A PV6.1 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D P ROFES S I O N A L E N GINEER P A U L K .ZAC H E R STRUCTURAL ONLY CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 9. 6 8 AC K W : 7. 0 4 MO D U L E S : 22 HE L E N S C H W A R Z - L A W T O N 20 9 N E L S O N A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 11/27/2025 DESIGNED BY: OOB MA R K I N G & L A B E L S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A INVERTER AC DISCONNECT NEC 690.14(C)(2) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES & JUNCTION BOXES Warning: Photovoltaic Power Source NEC 690.35(F) UNGROUNDED SYSTEMS JUNCTION BOX WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NEC 705.12(D)(7) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED BREAKER. IF INSTALLED ANYWHERE ELSE ON DEADFRONT THEN A PERMANENT ARROW FROM LABEL POINTING TO PV BACKFEED BREAKER REQUIRED. MAIN SERVICE PANEL WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. WARNING NEC 705.12(D)(4)), 690.56(B) POWER IS BEING SUPPLIED TO THIS PANEL FROM THE UTILITY AND A SOLAR PV SYSTEM. NEC 690.54 RATED AC OUTPUT CURRENT: _____ A29.26 NOMINAL AC VOLTAGE: _____ V240 NEC 690.14(C)(2) PHOTOVOLTAIC AC DISCONNECT NEC 690.54 RATED AC OUTPUT CURRENT: _____ A 240 29.26 NOMINAL AC VOLTAGE: _____ V NEC 690.52 PHOTOVOLTAIC ARRAY DC DISCONNECT NOMINAL OPERATING AC VOLTAGE: 240 V NOMINAL OPERATING AC FREQUENCY: 60HZ MAX. AC POWER: 320 VA MAX AC CURRENT: 1.33 A MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT:20A NEC 690.13(4) SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION ONLY CONDUCTORS INSIDE BUILDING OR OFF THE ROOF WILL SHUT DOWN EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.56 NEC 690.31(D)(2) CONDUIT PV7 209 NELSON AVE, SARATOGA SPRINGS, NY 12866,EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R STRUCTURAL ONLY eng.hd-hyundaies.co.kr HD HYUNDAI SOLAR MODULE NF(BK) Series Premium N-Type TOPCon Module HiS-T430NF(BK) Ι HiS-T435NF(BK) Ι HiS-T440NF(BK) • 25-Year Product Warranty · Materials and workmanship • 30-Year Performance Warranty · First year degradation: 1% · Linear warranty after initial year: with 0.4%p annual degradation, 87.4% is guaranteed up to 30years 25 30 HD Hyundai's Warranty Provisions Higher Bifaciality Long-Term Reliability 22.53% High Efficiency 22.53% High-End TOPCon Technology TOPConTOPCon For Residential (Full Black Design) *Refer to HD HES standard warranty for details. HD HES TOPCon Module PERC Standard 0 80% 85% 90% 95% 100% 99% 89.4%87.4% 5 10 15 20 25 30 Certification · UL 61215 / UL 61730 / IEC 61215 / IEC 61730 Certified · ISO 9001 : Quality management systems · ISO 14001 : Environmental management systems · ISO 45001 : Occupational health and safety management systems Sales & Marketing hes.sales@hd.com Current [A] Voltage [V] 16 14 12 10 8 6 4 2 0 0 10 20 30 40 Irradiance = 1,000W/m2 Irradiance = 800W/m2 Irradiance = 600W/m2 Irradiance = 400W/m2 Irradiance = 200W/m2 Current [A] Voltage [V] 16 14 12 10 8 6 4 2 0 0 10 20 30 40 Operating Cell Temp = 5°C Operating Cell Temp = 25°C Operating Cell Temp = 45°C Operating Cell Temp = 65°C HiS-TxxxNF(BK)HiS-T430NF(BK)HiS-T435NF(BK)HiS-T440NF(BK) Item Unit BNPI BNPI BNPI Nominal output (Pmax)W 430 477 435 482 440 487 Open circuit voltage (Voc)V 39.49 39.64 39.69 39.84 39.90 40.05 Short circuit current (Isc)A 13.83 15.32 13.91 15.41 14.06 15.58 Voltage at Pmax (Vmpp)V 32.51 32.70 32.74 32.87 32.82 32.95 Current at Pmax (Impp)A 13.23 14.59 13.29 14.67 13.41 14.79 Module efficiency %22.02 22.28 22.53 Power Class Sorting W 0 ~ +5 Temperature coefficient of Pmax %/K -0.290 Temperature coefficient of Voc %/K -0.250 Temperature coefficient of Isc %/K 0.043 Bifaciality %80±5 *STC : Irradiance 1,000 W/m², cell temperature 25℃, AM=1.5 / Test uncertainty for Pmax ±3%; Isc; Voc ±5% **The electrical properties of BNPI are measured under the irradiance corresponding to 1000 W/m² on the module front and 135 W/m² on the module rear. I-V Curves (HiS-T440NF(BK)) FRONT SIDE REAR BA R C O D E 30 29 6 ±1 0 8±5 FR O N T RE A R Detail A 9 14 19 28 Long Frame 30 28 Short Frame 30 12.2 A 12- Ø9x14 Mounting Holes 4- Ø5.5 Grounding Holes 13 0 0 10 0 0 20 0 1096±2 BARCODENAMEPLATE 1134±2 17 2 2 ±2 Module Diagram (unit : mm) HD Hyundai Energy Solutions reserves the right to update or modify the specifications and features listed in this datasheet without prior notice. Always check the latest version of the datasheet for accurate information. Before using the product, please refer to the Installation and Operation Manual and Warranty. We retain the right of final interpretation. Shipping Configurations Container Size (HC)40'Modules Per Pallet (pcs) 36 Pallets Per Container 22 Modules Per Container (pcs) 792 Mechanical Characteristics Dimensions 1,722mm (L) x 1,134mm (W) x 30mm (H) (67.8in x 44.6in x 1.2in) Weight 24.3 kg (53.57 lbs) Solar Cells N-Type TOPCon, 108 (6x18) monocrystalline 16BB half-cut bifacial cells Output Cables Cable : (+)1,200mm(47.2in), (-)1,200mm(47.2in) / Customized length available Connector : Stäubli MC4 genuine Connector / IP68 Junction Box 3-part, 3 bypass diodes, IP68 rated Construction Front : 2.0mm(0.08in) semi-tempered solar glass with high transmittance and anti-reflective coating Rear : 2.0mm(0.08in) semi-tempered solar glass Frame Anodized aluminum alloy Electrical Characteristics Additional Power Gain from rear side Pmpp gain Pmpp[W]Vmpp[V]Impp[A]Voc[V]Isc[A] 5%462 32.82 14.08 39.90 14.77 15%506 32.82 15.42 39.90 16.17 25%550 32.82 16.76 39.90 17.58 *Electrical characteristics with different rear power gain (reference to 440W) Installation Safety Guide • Only qualified personnel should install or perform maintenance. • Be aware of dangerous high DC voltage. • Do not handle or install modules when they are wet. Nominal Module Operation Temperature 41℃ ± 2℃ Operating Temperature -40℃~+85℃ Maximum System Voltage DC 1,500 V Maximum Reverse Current 30A Maximum Test Load Front 5,400Pa Rear 4,500Pa Fire Performance Type 29 IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 DATA SHEET IQ8MC Microinverter Our newest IQ8 Series Microinverters are the industry’s first microgrid-forming*, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. *Meets UL 1741 only when installed with IQ System Controller 2 or 3. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conforms with various regulations when installed according to the manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters that have integrated MC4 connectors. Easy to install • Lightweight and compact with plug-and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produces power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative. An IQ Gateway is required to make these changes during installation. © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQ8MC-MC4-DSH-00049-4.0-EN-US-2024-02-09 (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MC Microinverter INPUT DATA (DC)UNITS IQ8MC-72-M-US Commonly used module pairings 1 W 260–460 Module compatibility —To meet compatibility, PV modules must be within the following max. input DC voltage and max. module Isc. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 25–45 Operating range V 18–58 Min./Max. start voltage V 22/58 Max. input DC voltage V 60 Max. continuous operating DC current A 14 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires max 20 A per branch circuit OUTPUT DATA (AC) UNITS IQ8MC-72-M-US @240 VAC IQ8MC-72-M-US @208 VAC Peak output power VA 330 315 Max. continuous output power VA 320 310 Nominal grid voltage (L-L) V 240, split-phase (L-L), 180°208, single-phase (L-L), 120° Min./Max. grid voltage 2 V 211–264 183–229 Max. continuous output current A 1.33 1.49 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short circuit fault current over three cycles Arms 2.70 Max. units per 20 A (L-L) branch circuit 3 —12 10 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 18 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading ... 0.85 lagging Peak efficiency %97.4 97.2 CEC weighted efficiency %97.0 96.5 Nighttime power consumption mW 33 25 MECHANICAL DATA UNITS Ambient temperature range -40°C to 65°C (-40°F to 149°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D); Weight 212 mm (8.3") × 175 mm (6.9") × 30.2 mm (1.2"); 1.1 kg (2.43 lbs) Cooling Natural convection – no fans Approved for wet locations; Pollution degree Yes; PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environ. category; UV exposure rating NEMA Type 6; outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01. This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer’s instructions.