Loading...
HomeMy WebLinkAbout20260177 10 Franklin St Franklin Community Center Construction ApplicationRevised 01/2021 APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ 95 Washington Street Saratoga Springs, NY 12866 City of Saratoga 474 Broadway Saratoga Springs NY 12866 Franklin Community Center Balzer & Tuck Architecture 468 Broadway Saratoga Springs, NY 12866 kari@franklincommunitycenter.org bbalzer@balzertuck.com 10 Franklin Street 165 66 2 89 NC (T-5) n Applicant proposes interior renovations to the property in order to expand resources for the food pantry and to house their Free Store. To support these improvements, the project includes an exterior ramp along Franklin Street to maintain accessible entry to the Free Store, as well as a walk-in freezer and cooler at the rear of the building to serve the food pantry. 11.6.25 20251017 518.587.9826 518.587.3550 518.580.8818 ~ 1983 **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 6 Page 1 of 3 Short Environmental Assessment Form Part 1 - Project Information Instructions for Completing Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part 1 – Project and Sponsor Information Name of Action or Project: Project Location (describe, and attach a location map): Brief Description of Proposed Action: Name of Applicant or Sponsor: Telephone: E-Mail: Address: City/PO: State: Zip Code: 1.Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that may be affected in the municipality and proceed to Part 2. If no, continue to question 2. NO YES 2.Does the proposed action require a permit, approval or funding from any other government Agency? If Yes, list agency(s) name and permit or approval:NO YES 3.a. Total acreage of the site of the proposed action? __________ acres b. Total acreage to be physically disturbed? __________ acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor? __________ acres 4.Check all land uses that occur on, are adjoining or near the proposed action: 5. Urban Rural (non-agriculture) Industrial Commercial Residential (suburban) Aquatic Other(Specify):□ Forest Agriculture □ Parkland Franklin Community Center 10 Franklin Street, Saratoga Springs NY 12866 Applicant proposes interior renovations to the property in order to expand resources for the food pantry and to house their Free Store. To support these improvements, the project includes an exterior ramp along Franklin Street to maintain accessible entry to the Free Store, as well as a walk-in freezer and cooler at the rear of the building to serve the food Balzer & Tuck Architecture 518.580.8818 bbalzer@balzertuck.com 468 Broadway, 3rd Floor Saratoga Springs NY 12866 4 Saratoga Springs Design Review Board approval and Building Permit 4 0.28 0.01 0.28 4 Page 2 of 3 5.Is the proposed action, a.A permitted use under the zoning regulations? b.Consistent with the adopted comprehensive plan? NO YES N/A 6.Is the proposed action consistent with the predominant character of the existing built or natural landscape?NO YES 7.Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? If Yes, identify: ________________________________________________________________________________ NO YES 8.a. Will the proposed action result in a substantial increase in traffic above present levels? b.Are public transportation services available at or near the site of the proposed action? c.Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed action? NO YES 9.Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 10.Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable water: _________________________________________ _____________________________________________________________________________________________ NO YES 11.Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: ______________________________________ _____________________________________________________________________________________________ NO YES 12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district which is listed on the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory? NO YES 13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? b.Would the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: _____________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Page 3 of 3 14.Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply: □Shoreline □ Forest Agricultural/grasslands Early mid-successional Wetland □ Urban Suburban 15.Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or Federal government as threatened or endangered?NO YES 16.Is the project site located in the 100-year flood plan?NO YES 17.Will the proposed action create storm water discharge, either from point or non-point sources? If Yes, a.Will storm water discharges flow to adjacent properties? b.Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 18.Does the proposed action include construction or other activities that would result in the impoundment of water or other liquids (e.g., retention pond, waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment:______________________________________________ ____________________________________________________________________________________________ _ NO YES 19.Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste management facility? If Yes, describe: _______________________________________________________________________________ _____________________________________________________________________________________________ NO YES 20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or completed) for hazardous waste? If Yes, describe: _______________________________________________________________________________ _____________________________________________________________________________________________ NO YES I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Date: _____________________ Applicant/sponsor/name: ____________________________________________________ __________________________ Signature: _____________________________________________________Title:__________________________________ 4 4 4 4 4 4 4 Brett Balzer, AIA February 20, 2026 Partner / Balzer & Tuck Architecture PRINT FORM 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 FRANKLIN COMMUNITY CENTER Historic Review Commision Application 03.06.26 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Sanborn Maps SANBORN MAP DATED 1900 SANBORN MAP DATED 1900-1950 SANBORN MAP DATED 1954 0'10' 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Existing Site Survey N ZONING DISTRICT NC (T-5) Section 21.Q.7 -For through lots, both the front and the rear required setbacks must meet the required front setback of the zoning district. Table 4-C -Commercial Mixed-Use Districts Dimensional Standards Required Existing Max. Building Height:50' Complies (1.1xROW or 50', whichever less) Min. Building Height:24’32' at Franklin; Complies 20' at Beekman; Existing non-compliant Building Height Stepback:N/A N/A Optional Height Exception:N/A N/A Optional Corner Lot Element:N/A N/A Max. Cumulative Area of New and Existing One-Story Structure(s):3,000sf Complies Property Line Setbacks Min. Public Right-of-Way:0’to 12’build-to zone Franklin; Complies Beekman; Existing non-compliant Min. Build-Out % Abutting ROW:70% 22.5% at Franklin; Existing non-compliant 40% at Beekman; Existing non-compliant Min. Side Setback 0’Complies Min. Rear Setback 0’N/A 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Existing Site Photos FRONT ELEVATION along FRANKLIN STREET MAIN ENTRY to EXISTING ADDITION REAR ENTRY to EXISTING ADDITION GARDEN at REAR 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Site Context Photos 10 FRANKLIN STREET / SAM'S TIRES & AUTOMOTIVE DOMINO'S PIZZA / 88 WASHINGTON / PARILLO SAUSAGE FRANKLIN COMMUNITY CENTER FRANKLIN COMMUNITY MANOR SAM'S TIRES & AUTOMOTIVE PARILLO SAUSAGE DIZZY CHICKEN BARBECUE DIZZY CHICKEN BARBECUE (WALK -IN COOLER)THE WEST SIDE SPORTS BAR & GRILL (WALK -IN COOLER) EX. SPLIT UNIT REF SHELVING SHELVING SHELVING REF REF CHEST CHEST REF D/W REF REF REF REF REF REF EXISTING SHED NAPA AUTOCARE CENTER S F R A N K L I N S T UP UP UP UP 103' - 8" 103' - 5 1/4" 100' - 0" WH EX. SPLIT UNIT UP DN PROPERTY LINE EXISTING LOAD BEARING WALL EXISTING LOAD BEARING WALL EXISTING CMU LOAD BEARING WALL EXISTING CMU LOAD BEARING WALL PROPOSED BACKUP GENERATOR PER DRB APPLICATION #20251017 M I N . S E T B A C K 5 ' - 0 " 0'2'4'8' 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 First Floor Demolition Plan N OFFICE (PROGRAM ASSISTANT) HALLWAY 546 SF FREE STORE ADA RESTROOM 625 SF OV ERFL O W / BACK STOR AGE 322 SF LOBBY 496 SF PANTRY STAIR GARDEN EXISTING SHED S F R A N K L I N S T 103' - 8" 103' - 5 1/4" 100' - 0" COMPUTER STATION HALLWAY OFFICE (FOOD PANTRY & FACILITIES MANAGER) ADA RESTROOM KITCHENETTE 39/256"24' - 3 217/256"8' - 8" WALK-IN-COOLER WALK-IN-FREEZER 5' - 3" 14' - 0" 14' - 0" 12' - 0" UTILITY / MECH. RM EXISTING WALL PROPOSED WALL PUBLIC SPACE SHARED SPACE PRIVATE SPACE (BACK OF HOUSE) EXTERIOR SPACE COLOR LEGEND: 103' - 8" NAPA AUTOCARE CENTER UP UP UP EXISTING CANOPY TO BE REPLACED NEW LOW WALL, PTD TO MATCH EXISTING REMOVE EXISTING DOOR AND SIDELITE AND INFILL WALL WITH 2x STUDS. ALIGN FREE STATION EX. CIRCUIT PANEL EX. SPLIT UNIT EX. SPLIT UNIT UP DN NEW BOTTLE FILLER STATION EX. SPLIT UNIT 2'-1" x 12'-4" SHELVING 3'-5" x 12'-4" DOUBLE-SIDED SHELVING 3'-5" x 12'-4" DOUBLE-SIDED SHELVING 1-PANEL FREEZER EXISTING ENTRY DOOR TO BE REPLACED W/ ALUM CLAD WOOD DOOR. PAINT FINISH TO MATCH FRANKLIN COMMUNITY CENTER "BLUE" NEW 8'-0" WIDE OPENING AT EXISTING LOAD BEARING WD STUD WALL. POSTS TO BE PROVIDED AT BASEMENT BELOW. NEW 8'-0" WIDE OPENING AT EXISTING LOAD BEARING WD STUD WALL NEW 4'-0" WIDE OPENING AT EXISTING LOAD BEARING WD STUD WALL NEW 9''-4" WIDE OPENING AT EXISTING LOAD BEARING WALL NEW 6''-5" WIDE OPENING AT EXISTING LOAD BEARING WALL KITCHENETTE WITH UNDERCOUNTER REFRIGERATOR, 18" HAND SINK, MICROWAVE AND COFFEE MAKER DN DN EXISTING WOOD DECKING TO BE REPLACED IN KIND EXISTING JOISTS AND POSTS TO BE REPAIRED AS REQUIRED TO RETAIN STRUCTURAL INTEGRITY OF PORCH. EXISTING FENCE TO REMAIN NEW RAMP W/ 5/4X6 STAINED WOOD DECKING W/ SLIP RESISTANT STRIPS AND AND SONOTUBE PIERS EXISTING ELECTRICAL METER 48" x 30" WORKING CLEARANCE PER NATIONAL GRID GUIDELINES EXISTING CHIMNEY TO REMAIN. REMOVAL WOULD REQUIRE INTRODUCTION OF STEEL BEAMS. EXISTING DOOR TO BE RETROFITTED WITH HOLD OPEN DOOR SYSTEM, TIED TO FIRE ALARM SYSTEM BUILT-IN SHELVING BUILT-IN SHELVING 3-PANEL REF 2-PANEL REF 2-PANEL FREEZER EXISTING WINDOWS AND MASONRY SILL TO BE REMOVED. PROVIDE NEW CONNECTION TO NEW WALK-IN COOLER AND PATCH WALL AS REQUIRED. ISLANDS TO BE PROVIDED WITH ELECTRIC OUTLET 36" REF. (P ICK- UPS) PROVIDE NEW ON-DEMAND WATER HEATER NEW ADA ACCESSIBLE RESTROOM WITH ADA COMPLIANT TOILET, SINK AND GRAB BARS. PROVIDE DIAPER CHANGING STATION. NEW ADA ACCESSIBLE RESTROOM WITH ADA COMPLIANT TOILET, SINK AND GRAB BARS. PROVIDE DIAPER CHANGING STATION. NEW MOP SINK 2' x 6' SHELVING 2' x 5' SHELVING 2' x 3' SHELVING 2' x 3' SHELVING 2' x 4' SHELVING 2' x 6' SHELVING 3' x 8' ISLAND 3' x 8' ISLAND 2' X 6' SHELVING 2' X 6' SHELVING 2' X 6' SHELVING 2' x 6' SHELVING 2' x 6' SHELVING 2' x 5' SHELVIN G 2' x 4' SHELVIN G 2' x 3' CART 2' x 3' CART 3'-5" x 12'-4" SHELVING NEW ALUM CLAD WOOD DOOR NEW POLAR KING EXTERIOR WALK-IN REFRIGERATOR & FREEZER COMBO . PROVIDE NEW CONCRETE SLAB IN COORDINATION WITH STRUCTURAL ENGINEER NEW PTD WD FENCE TO MATCH EXISTING EXISTING DOOR TO BE REPAINTED NEW 2'-4" x 3'-2" WINDOW AND OPENING IN EXISTING CMU WALL 2' x 6' PICK-UP SHELF GREETING DESK ALIGN +/-101' -7" EXISTING WINDOW OPENING AND MASONRY SILL TO BE REMOVED FOR A NEW 1-PANEL GLASS INSWING DOOR NEW PAINTED METAL RAILINGS 36" AFF. EDGE PROTECTION TO BE PROVIDED VIA HORIZONTAL RAIL MAXIMUM 4" ABOVE RAMP FLOOR. REF. SIM. PROPOSED RAMP M I N . S E T B A C K 5 ' - 0 " PROPOSED BACKUP GENERATOR PER DRB APPLICATION #20251017 S F R A N K L I N S T E B E E K M A N S T NEW WALK - IN COOLER NEW ADA RAMP 0'2'4'8' 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Proposed First Floor Plan N KEY PLAN: 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Rendering of Proposed ADA Accessible Ramp NEW DOOR EXISTING HOLLOW METAL DOOR TO BE REPLACED NEW ADA ACCESSIBLE RAMP. 5/4x6 STAINED WOOD DECKING W/ SLIP RESISTANT STRIPS 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Rendering of Main Entry Door EXISTING DOOR TO BE REPAINTED 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Rendering of Proposed Walk -in Cooler NEW WINDOW NEW WALK-IN COOLER 468 BROADWAY SARATOGA SPRINGS NY 12866 P 518.580.8818 F 518.580.8824BALZERTUCK.COM FRANKLIN COMMUNITY CENTER BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866 Rendering of Proposed Rear Entry EXISTING DOOR TO BE REPLACED NEW WINDOW NEW WALK -IN COOLER DRC Window Details Form 1, 5/16/21 Page# ___ of ___ Window Details Form Instructions: Provide details and photos for EACH window replacement requested. Use additional pages of Form 1 or Form 1a as necessary. For ease of review, documentation should be categorized by façade. SEE EXAMPLE. Building Elevation: _____________________ Insert photo above. Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration: Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Unknown; painted hollow core metal door. Yes. No. No. Scratching, rust and wear at interior. More transparency to/from inside the "Free Store". Aluminum clad wood door. Refer to drawings. Yes. Yes. 1 6 1 - Secondary Entry Door 1 2 DRC Window Details Form 1a, 5/16/21 Page# ___ of ___ Building Elevation: _____________________ Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration: Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Unknown; wood replacement window. Yes. Yes. No. Wear, chipped paint. "Free Store" requires an accessible entry. Aluminum clad wood door. Refer to drawings. Yes. New trim to match existing at removed section of masonry. Height enlarged to permit install of door. 2 6 2 - Window DRC Window Details Form 1, 5/16/21 Page# ___ of ___ Window Details Form Instructions: Provide details and photos for EACH window replacement requested. Use additional pages of Form 1 or Form 1a as necessary. For ease of review, documentation should be categorized by façade. SEE EXAMPLE. Building Elevation: _____________________ Insert photo above. Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration: Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: West Elevation ~ 2022; hollow core metal door. Yes. No. No. N/A No replacement required. Repaint only. N/A Yes. N/A 3 6 3 - Main Entry Door 4 3 4 DRC Window Details Form 1a, 5/16/21 Page# ___ of ___ Building Elevation: _____________________ Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration: Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Addition built ~ 1983; extruded aluminum storefront system. N/A N/A No. Sill is rusted out and deteriorating. Components of the extruded aluminum storefront system can be replaced in kind. Replace sill in kind. Yes. Yes. 4 6 4 - Main Entry Sidelites DRC Window Details Form 1, 5/16/21 Page# ___ of ___ Window Details Form Instructions: Provide details and photos for EACH window replacement requested. Use additional pages of Form 1 or Form 1a as necessary. For ease of review, documentation should be categorized by façade. SEE EXAMPLE. Building Elevation: _____________________ Insert photo above. Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration: Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Rear (East Elevation) Addition built ~ 1983; painted hollow core metal door. Yes. No. No. Wear due to deliveries. Improve function and security. Aluminum clad wood door. Refer to drawings. Yes. Yes. 5 6 5 - Rear Door 5 6 DRC Window Details Form 1a, 5/16/21 Page# ___ of ___ Building Elevation: _____________________ Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration: Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Details for Existing Window ID: Insert photo below showing existing condition. Original window? If no, what is the general replacement date? If operable, does the window open? If no, why? Storm window present? If yes, what type? Boarded up? If yes, is window still in place? Explanation of visible rot or deterioration Extenuating circumstances requiring replacement vs. repair Proposed Replacement, material and muntins: Will trim and casing details remain the same? Is proposed window the same size and same location as original? Explain: Addition built ~ 1983; vinyl windows. Yes. No. No. N/A Applicant wishes to provide interior access to outdoor walk-in-cooler. N/A Trim to be removed. N/A 6 6 6 - Rear Window ENTRY DOORS Dimensions & Specifications Guide UNLIMITED POSSIBILITIES TO CREATE YOUR ORIGINAL E-SERIES Architectural Collection E-SERIES CASEMENT WINDOWS FOR WINDOWS GREATER THAN 30 SQUARE FEET OR RATED HIGHER THAN PG50, ONE OF THESE THREE INSTALLATION METHODS IS REQUIRED: A) THROUGH THE JAMB B) ALUMINUM INSTALLATION FLANGE OR C) INSTALLATION CLIPS. ADDITIONAL CUSTOM SIZES ARE AVAILABLE. CONTACT YOUR LOCAL SUPPLIER FOR MORE INFORMATION. DRAWINGS ARE NOT TO SCALE. R.O . F.S . 1' 6 1/4" 1' 5 3/4" 1' 8 1/2" 1' 8" 2' 0 1/2" 2' 0" 2' 4 1/2" 2' 4" 2' 6 1/2" 2' 6" 2' 8 1/2" 2' 8" 3' 0 1/2" 3' 0" 2' 0 1/ 2" 2' 0 " 2' 6 1/ 2" 2' 6 " 2' 8 1/ 2" 2' 8 " 3' 0 1/ 2" 3' 0 " 3' 4 1/ 2" 3' 4 " 4' 0 1/ 2" 4' 0 " 4' 6 1/ 2" 4' 6 " 5' 0 1/ 2" 5' 0 " 5' 6 1/ 2" 5' 6 " 6' 0 1/ 2" 6' 0 " CAX15 3/4 20 CAX1820 CAX2020 CAX15 3/4 26 CAX1826 CAX2026 CAX2426 CAX2626 CAX15 3/4 28 CAX1828 CAX2028 CAX2428 CAX2628 CAX2828 CAX15 3/4 30 CAX1830 CAX2030 CAX2430 CAX2630 CAX2830 CAX3030 CAX15 3/4 34 CAX1834 CAX2034 CAX2434 CAX2634 CAX2834 CAX3034 CAX15 3/4 40 CAX1840 CAX2040 CAX2440 ††CAX2640 †CAX2840 †CAX3040 † CAX15 3/4 46 CAX1846 CAX2046 CAX2446 ††CAX2646 †CAX2846 †CAX3046 † CAX15 3/4 50 CAX1850 CAX2050 CAX2450 ††CAX2650 †CAX2850 †CAX3050 * CAX15 3/4 56 CAX1856 CAX2056 CAX2456 ††CAX2656 †CAX2856 *CAX3056 ** CAX15 3/4 60 CAX1860 CAX2060 CAX2460 ††CAX2660 †CAX2860 **CAX3060 ** CAX2420 CAX2620 CAX2820 CAX3020 CAX2826 CAX3026 CAX3028 Casement Window Sizes 2- Wide 3-Wide 4-Wide 5-Wide Single UnitFrame Width RoughOpening Width Frame Width RoughOpening Width RoughOpening Width RoughOpening Width 1'-5 3/4"3'-0"2'-11 1/2" 4'-5 3/4"4'-5 1/4" 5'-11 1/2"5'-11"7'-5 1/4"7'-4 3/4" 1'-8"3'-4 1/2"3'-4"5'-0 1/2"5'-0"6'-8 1/2"6'-8"8'-4 1/2"8'-4" 2'-0"4'-0 1/2"4'-0"6'-0 1/2"6'-0"8'-0 1/2"8'-0"10'-0 1/2"10'-0" 2'-4"4'-8 1/2"4'-8"7'-0 1/2"7'-0"9'-4 1/2"9'-4"11 '-8 1/2"11 '-8" 2'-6"5'-0 1/2"5'-0"7'-6 1/2"7'-6"10'-0 1/2"10'-0"12'-6 1/2"12'-6" 2'-8"5'-4 1/2"5'-4"8'-0 1/2"8'-0"10'-8 1/2"10'-8"13'-4 1/2"13'-4" 3'-0"6'-0 1/2"6'-0"9'-0 1/2"9'-0"12'-0 1/2"12'-0"15'-0 1/2"15'-0" FrameWidth FrameWidth FrameWidth JoinedCasementCombinations NOTES † These units meet or exceed the following dimensions: Clear Opening Area 5.7 sq. ft., Clear Opening Width 20", Clear Opening Height 24" and 44" maximum floor to sill height (with standard 6' 10-1/2" structural header height). †† Units meet the stated dimensions above when optional hardware for widest clear opening is used. * A sash-limiting device is standard on 2856 and 3050 casement units. See your local code official for requirements in your area. ** A piano hinge and sash limiting device is standard on 2860, 3056 and 3060 casement units. If glass is positioned within 18" of the finished floor, safety/tempered glass may be required. Local codes may differ. Verify tempered glass requirements with your local building code official. Use structural joining material when necessary or required by code. The light patterns illustrated apply to rectangular removable interior wood grilles, Full Divided Light, Simulated Divided Light, Decorelle 100, 150 and 400 and Finelight™ Grilles-Between-the-Glass. All removable interior wood grilles will be installed in the units unless otherwise specified. For a metric conversion in millimeters, multiply dimensions in inches by 25.4. FORMULA FOR COMBINATION WINDOWS The overall frame dimension (both width and height) is equal to the sum of the individual unit frame dimensions plus joining material dimension(s). The overall rough opening (both width and height) is equal to the overall frame dimensions plus 1/4" on all sides. Any unit within each combination can be operating or stationary. Vent Layout as Viewed From Exterior StationaryLeft Right 2020 E-Series Product Guide Page 1 of 5 5 *Visit andersenwindows.com/warranty for details. Printing limitations prevent exact color duplication. Please see your Andersen supplier for actual color samples. CUSTOM EXTERIORS OR 2-, 3- AND 4-TONE EXTERIORS Choose a custom exterior color to get just the right color for your design. And, with our 2-, 3- and 4-tone color combinations, the sky’s the limit. Mix and match up to four of our 50 exterior colors for a combination look that’s all your own. EXTERIOR TRIM Choose exterior trim in either a flat casing, brick mould or sill nosing profile to add curb appeal to your home. Light Bronze Medium Bronze Champagne Dark BronzeClear Anodized Copper Black 2" brick mould and 1 1/2" sill nose, shown on a casement window Colony white and black 7 ANODIZED FINISHES Colony White White Abalone Balsa White Canvas Maple Syrup Harvest Gold Pebble Tan Carmel Bourbon Acorn Coffee Bean Aquamarine Patina Country Blue Blue Denim Caribbean Blue Slate Sage Billiard Green Moss Forest Green Sky Blue Moody Blue Sierra Bronze Dark Bronze Mallard Green Watercolor Blue Smokey Gray Mystic Gray FlagstonePrairie Grass Sandtone Clay Canyon Harbor Mist Spearmint Terratone Hot Chocolate Cocoa Bean Fire Engine Red Cardinal Cinnamon Toast Bing Cherry OliveRed Rock Stormy Blue Yorktown Pewter Dark AshDove Gray Black DO YOU DREAM IN COLOR? While our large selection of 50 exterior colors covers a lot of ground, inspiration comes in infinite hues. Let us match a paint chip, a photograph or a favorite work of art to bring your dream color into the light of day. Or, choose from a selection of anodized finishes for a rich, lustrous metallic appearance that cannot peel or flake and is not affected by sunlight.* EXTERIOR COLORS Design your window at andersenwindows.com/design-tool CHK'D BY: DATE PRINTED: OF OF DATE DRAWN: SHEET: BOX: DRW#: BY: SCALE: 1 1/16/2026 1/14/2026 CMO 4 1 3/16" = 1'-0" 1 BA L Z E R & T U C K A R C HI T E C T U R E SA R A T O G A S P R I N G S , N Y FO O D P A N T R Y SA R A T O G A S P R I N G S , N Y 1 26 - I B - 2 9 3 7 1 . 0 0 . 0 1 - 0 0 Outdoor freezer/cooler combo Vinyl NSF gasket (1/16" joint thickness), Cam-lock layout SN1 SPECIAL INSTRUCTIONS Tamper-proof fasteners Standard crating WALL PANELS Construction: 4" urethane (R-32) Exterior Finish: 24 ga. galvanneal / 26 ga. stucco galvalume Interior Finish: 26 ga. stucco galvalume Ceiling connections: Camlock Floor connections: Camlock CEILING PANELS Construction: 5 1/2" wood frame urethane (R-44) Exterior Finish: Metal Interior Finish: 26 ga. stucco galvalume Ceiling Caps: No ceiling trim Live Load: 195 psf DOORS [A]: 34" x 78" flush model G3 self-closing freezer door *** TAMPER-PROOF FASTENERS *** *** ELECTRICAL COMPONENTS PRE-WIRED *** *** LEAF NOT RAISED FOR FLOORING *** Brand: Imperial Brown Frame: 4" high density urethane (R-32), 3-sided w/ 26 ga. stucco galvalume both sides w/ 24 ga. stainless steel 430 (magnetic) liners w/ 4-sided heat cable in frame [FL-4-117W] (24'-9" x 5 ohms/ft (124 total) @ 4.8 W/ft + Pepi - 120V, 1A) Leaf: 4" thick, 3-side lap, standard height w/ 26 ga. stucco galvalume both sides w/ Magnetic gasket w/ 2 1/4" black neoprene sweep (3) Component Hardware #W59 spring assisted adjustable hinge (1) Kason #27C cylinder locking deadbolt handle (1) Kason #27C twist-off knob inside release (1) Kason 'PUSH' pad (1) Kason #1094 hydraulic door closer (polished chrome) (1) Single pole toggle switch w/ pilot light (120V, 10A max. load) @ ext. (1) 2" flush mount analog thermometer w/ 12" capillary (1) Terminal J-Box @ int. (1) Kason 1832 heated air vent (23W, 120V, .2A) (1) .080 smooth aluminum threshold [B]: 34" x 78" flush model G3 self-closing cooler door *** TAMPER-PROOF FASTENERS *** *** ELECTRICAL COMPONENTS PRE-WIRED *** *** LEAF WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE *** Brand: Imperial Brown Frame: 4" high density urethane (R-32), 3-sided w/ 26 ga. stucco galvalume both sides w/ 24 ga. stainless steel 430 (magnetic) liners Leaf: 4" thick, 3-side lap, standard height w/ 26 ga. stucco galvalume both sides w/ Magnetic gasket w/ 2 1/4" black neoprene sweep (3) Component Hardware #W59 spring assisted adjustable hinge (1) Kason #27C cylinder locking deadbolt handle (1) Kason #27C twist-off knob inside release (1) Kason 'PUSH' pad (1) Kason #1094 hydraulic door closer (polished chrome) (1) Single pole toggle switch w/ pilot light (120V, 10A max. load) @ ext. (1) 2" flush mount analog thermometer w/ 12" capillary (1) Terminal J-Box @ int. (1) .080 smooth aluminum threshold PARTS (2) ea. 4' LED light fixture #LED-440079 for cooler or freezer application (65W, 120-277V, 0.6-0.3A)-(Fixture ships loose for field installation.) (37) ea. Prefabricated floor seismic restraint system-Simpson Titen or similar concrete screws @ 24"o/c (12) ea. Interior seismic tie-down @ ceiling level-(2" x 2") x 96" x 26 ga. stucco galvalume (1) Pkg. Sloped roof - Membrane roofing-Cut size: 17ft x 15ft - High end: 17ft side - Rise: 2 in.w/ (1) roll Duro-Blue protective film (Attaches to building on 12' - 0" side of box.) [QBRCS-168] (1) Pkg. Sloped roof - ISO boards-[4 AA, 4 A, 4 B, 0 C, 0 Flat] (6) ea. 'TB' membrane roofing trim, 96" long-24 ga. galvanneal (2) ea. (2" x 4") x 96" x 24 ga. galvanneal outside corner vertical closure (2) ea. (2" x 4") x 48" x 24 ga. galvanneal outside corner vertical closure (2) ea. (2" x 4") x 96" x Stucco galvalume outside corner vertical closure (2) ea. (2" x 4") x 48" x Stucco galvalume outside corner vertical closure REFRIGERATION (1) ea. Freezer - Outdoor R454a split system w/ EcoNET 9734 BTU/H @ 10.7F TD, 14.8 hr runtime @ -10F inside/95F outside room 90F @ cond. unit, 307ft altitude (1) Russell R454a air cooled condensing unit #RFON250L4ADA-NT 208-230V/1ø/60Hz/2.5HP Scroll compressor MCA=21, MOPD =35, AWEF: 3.15 39.875W x 28.25D x 21.25H x 240lbs. (1) Russell R454a Next-Gen All-Temp evaporator model #RAL6E092DDARSF w/ (2) DSE motors (1A) & electric defrost (9.8A) 208-230V/1ø/60Hz 43.625W x 15.5D x 18.125H x 50lbs. Includes (1) ea. Russell outside line check valve for Next-Gen All-Temp evaporators (1-4 fans) (1) ea. Russell outside line solenoid valve for Next-Gen All-Temp evaporators (1-4 fans) (1) ea. Cooler - Outdoor R454a split system w/ EcoNET 7559 BTU/H @ 9.4F TD, 12.8 hr runtime @ 35F inside/95F outside room 90F @ cond. unit, 307ft altitude (1) Russell R454a air cooled condensing unit #RFON060M4ADA-NT 208-230V/1ø/60Hz/0.5HP Scroll compressor MCA=15, MOPD =15, AWEF: 7.6 27.875W x 28.25D x 18.75H x 195lbs. (1) Russell R454a Next-Gen All-Temp evaporator model #RAL6A081ADARSF w/ (1) DSE motors (0.8A) & air defrost 115V/1ø/60Hz 27.125W x 15.5D x 18.125H x 42lbs. Includes (1) ea. Russell outside line check valve for Next-Gen All-Temp evaporators (1-4 fans) (1) ea. Russell outside line solenoid valve for Next-Gen All-Temp evaporators (1-4 fans) Meets 2009 Federal Energy Independence and Security Act Requirements. STANDARD NOTES To prevent condensation, a minimum 2" from the walk-in exterior surface is required. High humidity conditions may require force ventilation in addition to clearance. Installation site floor must be true and level within 3/16" per 10' or additional costs may be incurred. R-Plus Doors sliding and vertical lift doors shall not be considered means of egress. Check code egress requirements for your application. ELECTRICAL Field electrician to verify maximum acceptable load for light switches.If load is too high, then relay type controls should be used. After wiring devices, ALL conduits must be sealed to stop moisture transfer through electrical raceways. Failure to seal device per NEC codes WILL VOID WARRANTY. NSF LABEL N.S.F. LISTED (STD #7) N.S.F. GASKET @ ALL PANEL JOINTS R - PRELIMINARY DRAWING - Customer Note: This is a preliminary drawing only. Approving this drawing only indicates that you agree with overall dimensions and door and opening locations. Panel sizes and layout is subject to change. If "Nominal Size" has been quoted, then actual dimensions may end up a bit smaller than drawn herein. Actual dimensions will be shown on subsequent non-preliminary drawings. Should discrepencies be found between drawing and sales order, customer may be asked to approve standard Submittal drawings. The customer or their repres entative in signing these drawings is taking responsibility for overall size and fit around building walls, columns and ceiling restrictions, door locations, openings for equipment supplied by others, specifications and accessories listed. APPROVED FOR FABRICATION WITH NO CHANGES APPROVED FOR FABRICATION WITH CHANGES REVISE AND RESUBMIT Signature: ____________________________________________ 22 1 / 8 W1 DC 45 1 5 / 1 6 W2 20 3 / 1 6 W3 39 11/16 W4 45 15/16 W5 11 3/411 3 / 4 W6 28 3 / 8 W7 45 1 5 / 1 6 W8 45 1 5 / 1 6 W9 11 3/4 11 3 / 4 W10 45 15/16 W11 39 11/16 W12 12 5/8 W13 DC 45 15/16 W14 11 3/4 11 3 / 4 W15 15 1 / 8 W1 6 45 1 5 / 1 6 W1 7 13 3 / 1 6 W1 8 11 3/411 3 / 4 W19 12 5/8 W20 45 15/16 W21 45 1 5 / 1 6 P N L [A ] 45 1 5 / 1 6 P N L [B ] FREEZER COOLER WALL PANELS 26 ga. stucco galvalume 24 ga. galvanneal 48 LC 96 LC 12 ' - 0 " [ 1 4 4 ] 8'-0" [96]6'-0" [72] 14'-0" [168] C1 26 1 3 / 1 6 97 1/2 P C C247 P C P C347 P C P C423 PP SL O P E D O W N C5 70 7/16 C C C6 C C P C7 C C P C8C P CEILING PANELS F1 23 14 4 C F2 47 CP F3 27 3/8 PP F4 23 3/8 CC F5 47 P FLOOR PANELS 4 1 / 4 W15 95 W16W17W18W19 95 95 5 1 / 2 8' - 8 3 / 4 " [ 1 0 4 3 / 4 ] ELEVATION W12 95 W1W2W3W4 95 ELEVATION 3 1/2" high density urethane (R-28) 4" high density urethane (R-32) 4" urethane (R-32) 5 1/2" wood frame urethane (R-44) CONSTRUCTION LEGEND: 48 50 1 / 8 Bu i l d i n g o p e n i n g [A] Backing @ int. for strip curtain S HVJ [B] Backing @ int. for strip curtain S HV J 8' - 1 0 3 / 4 " [ 1 0 6 3 / 4 ] 2 CHK'D BY: DATE PRINTED: OF OF DATE DRAWN: SHEET: BOX: DRW#: BY: SCALE: 2 1/16/2026 1/14/2026 CMO 4 1 3/16" = 1'-0" 1 BA L Z E R & T U C K A R C HI T E C T U R E SA R A T O G A S P R I N G S , N Y FO O D P A N T R Y SA R A T O G A S P R I N G S , N Y 2 26 - I B - 2 9 3 7 1 . 0 0 . 0 1 - 0 0 4 1 / 4 95 5 1 / 2 8' - 8 3 / 4 " [ 1 0 4 3 / 4 ] 8' - 1 0 3 / 4 " [ 1 0 6 3 / 4 ] 2 VERTICAL CLOSURES Building Wall Walk-In Wall Building Wall Walk-In Wall 4 2 #8 x 1/2" MTHSMS @ 12"#8 x 1/2" MTHSMS @ 12" #8 x 1/2" MTHSMS @ 12" 4 2" Air Space2" Air Space MEMBRANE ROOFING Attached to Building, 'TB' Facia Trim Caulk with sealant (by others than manufacturer) Building wall Termination bar 2" Air Gap Ceiling panel Wall panel 10 9 3 / 4 "NSF" stamp both edges of the retainer strip "Open" hem w/ 1/2" lips TYP. both edges Duro-Last membrane roofing Polyurethane tapered ISO boards (4' x 4' sheets) 12" 1/8" 1/ 2 'TB' trim corner (2) #8 x 12" MTHSMS ea. leg 'TB' trim (slide over retainer strip) 'TB' retainer strip, pre-punched TRIM CORNER DETAIL NOTES: -Membrane roofing to be installed by Duro-Last approved installers or roofing warranty will be void. -Do not fasten retainer strip into ISO boards 'TB' trim over 24 ga. smooth galv. retainer strip w/ (2) ea. #10 x 11 2" PHSMS @ 12" O/C EXT.INT. Wall panel Wear surface 1/ 2 3 1 / 2 1/2" Underlayment 2" x 2" x 16 ga. galv. angle w/ 3/8" x 3" concrete seismic screw anchor @ 24" o/c into floor (min. embed 2 1/2") (4" min. concrete) 4 1 / 4 Concrete slab (By others than IB) Counter sink to base angle and drill base angle in field for anchors, free foam after inspection 3 1/2" HTFN FLOOR with Concealed Tie-Down 2" x 2" x cont. w/ #8 x 1/2" MTHSMS @ 12" o/c @ ea. leg w/ (4) ea. #8 @ splices @ ea. leg 1 1 SPLICE DETAIL 11 1 5 Minimum Overlap Ceiling panel Wall panel Camlocks @ 24" o/c CEILING TIE-DOWN CHK'D BY: DATE PRINTED: OF OF DATE DRAWN: SHEET: BOX: DRW#: BY: SCALE: 3 1/16/2026 1/14/2026 CMO 4 1 3/16" = 1'-0" 1 BA L Z E R & T U C K A R C HI T E C T U R E SA R A T O G A S P R I N G S , N Y FO O D P A N T R Y SA R A T O G A S P R I N G S , N Y 3 26 - I B - 2 9 3 7 1 . 0 0 . 0 1 - 0 0 www.Imperial-Brown.com | Sales@Imperial-Brown.com Stucco Aluminum Stucco Galvanized Stucco Black Galv. Available Metal and Other Finishes Smooth Sandstone www.Imperial-Brown.com | Sales@Imperial-Brown.com East Coast Factory 209 Long Meadow Drive Salisbury, NC 28147 Local (704) 636-5131 Toll Free (800) 438-2316 West Coast Factory 198 SE 223rd Ave. Gresham, OR 97030 Local (503) 665-5539 Toll Free (800) 238-4093 Midwest Factory 2115 W. Main Street Prague, OK 74864 Local (405) 567-1960 Toll Free (800) 238-4093 Available Metal and Other Finishes Stucco White Galv.Galvanneal Smooth Stainless Steel Stucco Galvalume