HomeMy WebLinkAbout20260177 10 Franklin St Franklin Community Center Construction ApplicationRevised 01/2021
APPLICATION FOR:
ARCHITECTURAL / HISTORIC REVIEW
APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT
Name
Address
Phone / / /
Email
Identify primary contact person: Applicant Owner Attorney/Agent
* An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question.
Applicant’s interest in premises: Owner Lessee Under option to lease or purchase
PROPERTY INFORMATION
Property Address/Location: Tax Parcel #: . - -
(for example: 165.52 – 4 – 37 )
Current Zoning District: Property use: Residential Non-residential/mixed-use
Type of Review: Architectural Historic Extension/modification (of current approval)
Summary description of proposed action:
Has a previous application been filed with the DRC for this property? No Yes – date(s)? _____________________
-App. No.(s)? _________________
Date Acquired by Owner: _________________
**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED**
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
CITY HALL - 474 BROADWAY
SARATOGA SPRINGS, NEW YORK 12866-2296
TEL: 518-587-3550 X2533
www.saratoga-springs.org
[FOR OFFICE USE]
_______________
(Application #)
____________
(Date received)
__________________________
(Project Title)
Staff Review _______________
95 Washington Street
Saratoga Springs, NY 12866
City of Saratoga
474 Broadway
Saratoga Springs NY 12866
Franklin Community Center Balzer & Tuck Architecture
468 Broadway
Saratoga Springs, NY 12866
kari@franklincommunitycenter.org bbalzer@balzertuck.com
10 Franklin Street 165 66 2 89
NC (T-5)
n
Applicant proposes interior renovations to the property in order to expand resources for the food pantry and to house
their Free Store. To support these improvements, the project includes an exterior ramp along Franklin Street to maintain
accessible entry to the Free Store, as well as a walk-in freezer and cooler at the rear of the building to serve the food
pantry.
11.6.25
20251017
518.587.9826 518.587.3550 518.580.8818
~ 1983
**A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other
materials as required below:
New Construction / Additions
Color photographs showing site/exterior details of existing structures and adjacent properties
A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures
along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all
setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning
district on 17"x11" sheet.
Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture
& lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible
Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible
Product literature, specifications and samples of proposed materials and colors
Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only)
Color photographs showing site/exterior details of existing structures and that illustrate affected features
Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp
type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible
Product literature, specifications and samples of proposed materials and colors
Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’)
-Installation, removal or change in material of drive- and walkways
-Installation or removal of architectural, sculptural or vegetative screening over 3’ in height
-Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter)
For any of above:
Color photographs showing site/exterior details of existing structures, and of adjacent properties
Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller
preferred if legible
Product literature, specifications and samples of proposed materials and colors
Signage / Awnings
Color photographs showing site/exterior details of existing structures, and adjacent properties
Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17”
Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type,
dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware
Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location
Product literature, specifications and samples of proposed materials and colors
Demolition
Color photographs showing site/exterior details of existing structures, and of adjacent properties
Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale
Written description of reasons for demolition and, in addition:
For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved
For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a
“contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition -
include a timetable and letter of credit for project completion
Telecommunication facilities
Color photographs showing site/existing structures, and of adjacent properties
Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale
Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details
Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact
assessment and existing and proposed vegetative screening
Revised 01/2021
Revised 01/2021
INSTRUCTIONS
ARCHITECTURAL / HISTORIC REVIEW APPLICATION
1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review
must be the property owner(s) or lessee, or have an option to lease or purchase the property in question.
2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is
complete. The DRC will only consider properly completed applications that contain 1 original and 1
digital version of the application and ALL other required materials as indicated on the application.
HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!!
3.ACTIONS REQUIRING REVIEW:
Architectural Review District Historic Review District
•any exterior changes that require a building permit
•any change in exterior building materials
•a new, or change to an existing, sign or sign structure
•demolition of a structure
Within a non-residential zoning district:
•a change in exterior building color
•installation of an awning
•Installation or exterior change to a structure requiring a
building or demolition permit
•any material change to exterior of a structure including:
-addition or removal of exterior architectural features
-installation, removal or material changes to exterior
building elements such as roof, siding, windows, doors,
porches, etc.
-enclosure or screening or buildings openings such as
windows, doors, porches, etc.
-installation of utility, mechanical or misc. accessory
structures to the exterior of a building such as HVAC
equipment, solar panels, wind turbines, radio/satellite
transmission/reception devices, etc.
Within a front yard setback:
-installation, removal or material changes to drive- or
walkways
-installation or removal of architectural, sculptural or
vegetative screening that exceeds 3’ in height
-installation of accessory utility structures or
radio/satellite transmission/reception devices over 2’ in
diameter
•a change in exterior building color within a non-
residential zoning district
•a new, or change to an existing, sign or awning
•installation of telecommunications facilities
Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance
is exempt from Historic or Architectural Review.
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x2533
www.saratoga-springs.org
4.DESIGN GUIDELINES:
The Design Review Commission will evaluate whether the proposed action (construction, alteration or
demolition) is compatible with existing structures and surrounding properties using the following criteria:
•Height – consistent with historic form and context of site and surrounding properties
•Scale – relationship of structure and its architectural elements to human size, form, perception
•Proportion – relationship among building elements including front façade, windows, and doors
•Rhythm – pattern resulting from repeating building elements such as door/window openings, columns,
arches, and other façade elements
•Directional Expression – compatibility with horizontal & vertical expression of surrounding structures
•Massing & Open Space – relationship of structure to open space between it and adjoining buildings
•Setback – compatibility with surrounding structures
•Compatibility of the following with surrounding structures/properties:
-Major building elements (storefronts, doors, windows, roof)
-Building materials
-Color – (in non-residential zoning districts only)
5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an
application. The DRC may impose appropriate conditions and safeguards in connection with its approval
including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied
DRC application on the grounds of hardship.
Application approvals shall expire within 18 months of the filing date unless the project has sufficiently
commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may
request up to 2 extensions if requested before expiration date of prior approval.
6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are
placed on an agenda on first-come, first-served basis as determined by the completeness of the application.
7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”.
REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT.
ADDITIONAL INFORMATION:
More detailed information on Architectural Review, Historic Review and the Design Review Commission
responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at
http://www.saratoga-springs.org/544/Zoning-Ordinance.
Revised 01/2021
6
Page 1 of 3
Short Environmental Assessment Form
Part 1 - Project Information
Instructions for Completing
Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the
application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on
information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as
thoroughly as possible based on current information.
Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the
lead agency; attach additional pages as necessary to supplement any item.
Part 1 – Project and Sponsor Information
Name of Action or Project:
Project Location (describe, and attach a location map):
Brief Description of Proposed Action:
Name of Applicant or Sponsor: Telephone:
E-Mail:
Address:
City/PO: State: Zip Code:
1.Does the proposed action only involve the legislative adoption of a plan, local law, ordinance,
administrative rule, or regulation?
If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that
may be affected in the municipality and proceed to Part 2. If no, continue to question 2.
NO YES
2.Does the proposed action require a permit, approval or funding from any other government Agency?
If Yes, list agency(s) name and permit or approval:NO YES
3.a. Total acreage of the site of the proposed action? __________ acres
b. Total acreage to be physically disturbed? __________ acres
c. Total acreage (project site and any contiguous properties) owned
or controlled by the applicant or project sponsor? __________ acres
4.Check all land uses that occur on, are adjoining or near the proposed action:
5. Urban Rural (non-agriculture) Industrial Commercial Residential (suburban)
Aquatic Other(Specify):□ Forest Agriculture
□ Parkland
Franklin Community Center
10 Franklin Street, Saratoga Springs NY 12866
Applicant proposes interior renovations to the property in order to expand resources for the food pantry and to house their Free Store. To support these
improvements, the project includes an exterior ramp along Franklin Street to maintain accessible entry to the Free Store, as well as a walk-in freezer
and cooler at the rear of the building to serve the food
Balzer & Tuck Architecture
518.580.8818
bbalzer@balzertuck.com
468 Broadway, 3rd Floor
Saratoga Springs NY 12866
4
Saratoga Springs Design Review Board approval and Building Permit 4
0.28
0.01
0.28
4
Page 2 of 3
5.Is the proposed action,
a.A permitted use under the zoning regulations?
b.Consistent with the adopted comprehensive plan?
NO YES N/A
6.Is the proposed action consistent with the predominant character of the existing built or natural landscape?NO YES
7.Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area?
If Yes, identify: ________________________________________________________________________________
NO YES
8.a. Will the proposed action result in a substantial increase in traffic above present levels?
b.Are public transportation services available at or near the site of the proposed action?
c.Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed
action?
NO YES
9.Does the proposed action meet or exceed the state energy code requirements?
If the proposed action will exceed requirements, describe design features and technologies:
_____________________________________________________________________________________________
_____________________________________________________________________________________________
NO YES
10.Will the proposed action connect to an existing public/private water supply?
If No, describe method for providing potable water: _________________________________________
_____________________________________________________________________________________________
NO YES
11.Will the proposed action connect to existing wastewater utilities?
If No, describe method for providing wastewater treatment: ______________________________________
_____________________________________________________________________________________________
NO YES
12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district
which is listed on the National or State Register of Historic Places, or that has been determined by the
Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the
State Register of Historic Places?
archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory?
NO YES
13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain
wetlands or other waterbodies regulated by a federal, state or local agency?
b.Would the proposed action physically alter, or encroach into, any existing wetland or waterbody?
If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: _____________________
_____________________________________________________________________________________________
_____________________________________________________________________________________________
NO YES
b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Page 3 of 3
14.Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply:
□Shoreline □ Forest Agricultural/grasslands Early mid-successional
Wetland □ Urban Suburban
15.Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or
Federal government as threatened or endangered?NO YES
16.Is the project site located in the 100-year flood plan?NO YES
17.Will the proposed action create storm water discharge, either from point or non-point sources?
If Yes,
a.Will storm water discharges flow to adjacent properties?
b.Will storm water discharges be directed to established conveyance systems (runoff and storm drains)?
If Yes, briefly describe:
_____________________________________________________________________________________________
_____________________________________________________________________________________________
NO YES
18.Does the proposed action include construction or other activities that would result in the impoundment of water
or other liquids (e.g., retention pond, waste lagoon, dam)?
If Yes, explain the purpose and size of the impoundment:______________________________________________
____________________________________________________________________________________________
_
NO YES
19.Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste
management facility?
If Yes, describe: _______________________________________________________________________________
_____________________________________________________________________________________________
NO YES
20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or
completed) for hazardous waste?
If Yes, describe: _______________________________________________________________________________
_____________________________________________________________________________________________
NO YES
I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF
MY KNOWLEDGE
Date: _____________________ Applicant/sponsor/name: ____________________________________________________ __________________________
Signature: _____________________________________________________Title:__________________________________
4
4
4
4
4
4
4
Brett Balzer, AIA February 20, 2026
Partner / Balzer & Tuck Architecture
PRINT FORM
10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
FRANKLIN COMMUNITY CENTER
Historic Review Commision Application
03.06.26
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Sanborn Maps
SANBORN MAP DATED 1900 SANBORN MAP DATED 1900-1950 SANBORN MAP DATED 1954
0'10'
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Existing Site Survey
N
ZONING DISTRICT NC (T-5)
Section 21.Q.7 -For through lots, both the front and the rear required setbacks must meet the required front setback of the zoning district.
Table 4-C -Commercial Mixed-Use Districts Dimensional Standards
Required Existing
Max. Building Height:50' Complies
(1.1xROW or 50', whichever less)
Min. Building Height:24’32' at Franklin; Complies
20' at Beekman; Existing non-compliant
Building Height Stepback:N/A N/A
Optional Height Exception:N/A N/A
Optional Corner Lot Element:N/A N/A
Max. Cumulative Area of New
and Existing One-Story Structure(s):3,000sf Complies
Property Line Setbacks
Min. Public Right-of-Way:0’to 12’build-to zone Franklin; Complies
Beekman; Existing non-compliant
Min. Build-Out % Abutting ROW:70% 22.5% at Franklin; Existing non-compliant
40% at Beekman; Existing non-compliant
Min. Side Setback 0’Complies
Min. Rear Setback 0’N/A
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Existing Site Photos
FRONT ELEVATION along FRANKLIN STREET
MAIN ENTRY to EXISTING ADDITION REAR ENTRY to EXISTING ADDITION GARDEN at REAR
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Site Context Photos
10 FRANKLIN STREET / SAM'S TIRES & AUTOMOTIVE
DOMINO'S PIZZA / 88 WASHINGTON / PARILLO SAUSAGE FRANKLIN COMMUNITY CENTER FRANKLIN COMMUNITY MANOR
SAM'S TIRES & AUTOMOTIVE PARILLO SAUSAGE
DIZZY CHICKEN BARBECUE DIZZY CHICKEN BARBECUE (WALK -IN COOLER)THE WEST SIDE SPORTS BAR & GRILL (WALK -IN COOLER)
EX. SPLIT UNIT
REF SHELVING
SHELVING
SHELVING
REF
REF
CHEST
CHEST
REF
D/W
REF
REF
REF
REF
REF
REF
EXISTING SHED
NAPA AUTOCARE CENTER
S F R A N K L I N S T
UP
UP
UP
UP
103' - 8"
103' - 5 1/4"
100' - 0"
WH
EX. SPLIT UNIT
UP DN
PROPERTY LINE
EXISTING LOAD
BEARING WALL
EXISTING LOAD
BEARING WALL
EXISTING CMU LOAD
BEARING WALL
EXISTING CMU LOAD
BEARING WALL
PROPOSED BACKUP GENERATOR PER
DRB APPLICATION #20251017
M
I
N
.
S
E
T
B
A
C
K
5
'
-
0
"
0'2'4'8'
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
First Floor Demolition Plan
N
OFFICE (PROGRAM ASSISTANT)
HALLWAY
546 SF
FREE STORE
ADA RESTROOM
625 SF
OV
ERFL
O
W /
BACK
STOR
AGE
322 SF
LOBBY
496 SF
PANTRY
STAIR
GARDEN
EXISTING SHED
S F R A N K L I N S T
103' - 8"
103' - 5 1/4"
100' - 0"
COMPUTER
STATION
HALLWAY
OFFICE (FOOD PANTRY &
FACILITIES MANAGER)
ADA RESTROOM
KITCHENETTE
39/256"24' - 3 217/256"8' - 8"
WALK-IN-COOLER WALK-IN-FREEZER
5' - 3"
14' - 0"
14' - 0"
12' - 0"
UTILITY / MECH. RM
EXISTING WALL
PROPOSED WALL
PUBLIC SPACE
SHARED SPACE
PRIVATE SPACE (BACK OF HOUSE)
EXTERIOR SPACE
COLOR LEGEND:
103' - 8"
NAPA AUTOCARE CENTER
UP
UP
UP
EXISTING CANOPY TO BE REPLACED
NEW LOW WALL, PTD
TO MATCH EXISTING
REMOVE EXISTING DOOR
AND SIDELITE AND INFILL
WALL WITH 2x STUDS.
ALIGN
FREE STATION
EX. CIRCUIT
PANEL
EX. SPLIT UNIT
EX. SPLIT UNIT
UP DN
NEW BOTTLE FILLER STATION
EX. SPLIT UNIT
2'-1" x 12'-4" SHELVING
3'-5" x 12'-4" DOUBLE-SIDED SHELVING
3'-5" x 12'-4" DOUBLE-SIDED SHELVING
1-PANEL
FREEZER
EXISTING ENTRY
DOOR TO BE
REPLACED W/
ALUM CLAD
WOOD DOOR.
PAINT FINISH TO
MATCH FRANKLIN
COMMUNITY
CENTER "BLUE"
NEW 8'-0" WIDE OPENING
AT EXISTING LOAD
BEARING WD STUD WALL.
POSTS TO BE PROVIDED
AT BASEMENT BELOW.
NEW 8'-0" WIDE OPENING
AT EXISTING LOAD
BEARING WD STUD WALL
NEW 4'-0" WIDE OPENING
AT EXISTING LOAD
BEARING WD STUD WALL
NEW 9''-4" WIDE
OPENING AT EXISTING
LOAD BEARING WALL
NEW 6''-5" WIDE
OPENING AT EXISTING
LOAD BEARING WALL
KITCHENETTE WITH UNDERCOUNTER
REFRIGERATOR, 18" HAND SINK,
MICROWAVE AND COFFEE MAKER
DN
DN
EXISTING WOOD
DECKING TO BE
REPLACED IN KIND
EXISTING JOISTS AND
POSTS TO BE REPAIRED
AS REQUIRED TO
RETAIN STRUCTURAL
INTEGRITY OF PORCH.
EXISTING FENCE
TO REMAIN
NEW RAMP W/ 5/4X6
STAINED WOOD
DECKING W/ SLIP
RESISTANT STRIPS AND
AND SONOTUBE PIERS
EXISTING ELECTRICAL METER
48" x 30" WORKING CLEARANCE
PER NATIONAL GRID GUIDELINES
EXISTING CHIMNEY TO
REMAIN. REMOVAL WOULD
REQUIRE INTRODUCTION
OF STEEL BEAMS.
EXISTING DOOR TO BE
RETROFITTED WITH HOLD
OPEN DOOR SYSTEM, TIED
TO FIRE ALARM SYSTEM
BUILT-IN
SHELVING
BUILT-IN
SHELVING
3-PANEL REF
2-PANEL REF
2-PANEL
FREEZER
EXISTING WINDOWS AND MASONRY SILL
TO BE REMOVED. PROVIDE NEW
CONNECTION TO NEW WALK-IN COOLER
AND PATCH WALL AS REQUIRED.
ISLANDS TO BE
PROVIDED WITH
ELECTRIC OUTLET
36" REF.
(P
ICK-
UPS)
PROVIDE NEW
ON-DEMAND
WATER HEATER
NEW ADA ACCESSIBLE
RESTROOM WITH ADA
COMPLIANT TOILET, SINK AND
GRAB BARS. PROVIDE DIAPER
CHANGING STATION.
NEW ADA ACCESSIBLE RESTROOM
WITH ADA COMPLIANT TOILET, SINK
AND GRAB BARS. PROVIDE DIAPER
CHANGING STATION.
NEW MOP SINK
2' x 6' SHELVING 2' x 5' SHELVING
2' x 3'
SHELVING
2' x 3'
SHELVING
2' x 4'
SHELVING 2' x 6' SHELVING
3' x 8' ISLAND
3' x 8' ISLAND
2' X 6' SHELVING 2' X 6' SHELVING 2' X 6' SHELVING
2' x 6' SHELVING
2' x 6' SHELVING
2' x 5'
SHELVIN
G
2' x 4'
SHELVIN
G
2' x 3'
CART
2' x 3'
CART
3'-5" x 12'-4" SHELVING
NEW ALUM CLAD
WOOD DOOR
NEW POLAR KING EXTERIOR WALK-IN REFRIGERATOR
& FREEZER COMBO . PROVIDE NEW CONCRETE SLAB
IN COORDINATION WITH STRUCTURAL ENGINEER
NEW PTD WD FENCE TO MATCH EXISTING
EXISTING DOOR
TO BE REPAINTED
NEW 2'-4" x 3'-2" WINDOW AND
OPENING IN EXISTING CMU WALL
2' x 6'
PICK-UP SHELF
GREETING DESK
ALIGN
+/-101' -7"
EXISTING WINDOW
OPENING AND MASONRY
SILL TO BE REMOVED
FOR A NEW 1-PANEL
GLASS INSWING DOOR
NEW PAINTED METAL RAILINGS 36" AFF. EDGE
PROTECTION TO BE PROVIDED VIA HORIZONTAL
RAIL MAXIMUM 4" ABOVE RAMP FLOOR.
REF.
SIM.
PROPOSED RAMP
M
I
N
.
S
E
T
B
A
C
K
5
'
-
0
"
PROPOSED BACKUP GENERATOR PER
DRB APPLICATION #20251017
S F R A N K L I N S T
E B E E K M A N S T
NEW WALK -
IN COOLER
NEW ADA
RAMP
0'2'4'8'
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Proposed First Floor Plan
N
KEY PLAN:
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Rendering of Proposed ADA Accessible Ramp
NEW DOOR
EXISTING HOLLOW
METAL DOOR TO BE
REPLACED
NEW ADA ACCESSIBLE
RAMP. 5/4x6 STAINED WOOD
DECKING W/ SLIP RESISTANT
STRIPS
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Rendering of Main Entry Door
EXISTING DOOR
TO BE REPAINTED
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Rendering of Proposed Walk -in Cooler
NEW WINDOW NEW WALK-IN COOLER
468 BROADWAY SARATOGA SPRINGS NY 12866
P 518.580.8818 F 518.580.8824BALZERTUCK.COM
FRANKLIN COMMUNITY CENTER
BTA PROJECT NO: 2518 03.06.26 10 FRANKLIN STREET, SARATOGA SPRINGS, NY 12866
Rendering of Proposed Rear Entry
EXISTING DOOR
TO BE REPLACED
NEW WINDOW
NEW WALK -IN COOLER
DRC Window Details Form 1, 5/16/21 Page# ___ of ___
Window Details Form
Instructions: Provide details and photos for EACH window replacement requested. Use additional pages of Form 1
or Form 1a as necessary. For ease of review, documentation should be categorized by façade. SEE EXAMPLE.
Building Elevation: _____________________ Insert photo above.
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration:
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Unknown; painted hollow core metal
door.
Yes.
No.
No.
Scratching, rust and wear at interior.
More transparency to/from inside the
"Free Store".
Aluminum clad wood door. Refer to
drawings.
Yes.
Yes.
1 6
1 - Secondary Entry Door
1 2
DRC Window Details Form 1a, 5/16/21 Page# ___ of ___
Building Elevation: _____________________
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration:
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Unknown; wood replacement
window.
Yes.
Yes.
No.
Wear, chipped paint.
"Free Store" requires an accessible
entry.
Aluminum clad wood door. Refer to
drawings.
Yes. New trim to match existing at
removed section of masonry.
Height enlarged to permit install of
door.
2 6
2 - Window
DRC Window Details Form 1, 5/16/21 Page# ___ of ___
Window Details Form
Instructions: Provide details and photos for EACH window replacement requested. Use additional pages of Form 1
or Form 1a as necessary. For ease of review, documentation should be categorized by façade. SEE EXAMPLE.
Building Elevation: _____________________ Insert photo above.
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration:
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
West Elevation
~ 2022; hollow core metal door.
Yes.
No.
No.
N/A
No replacement required. Repaint
only.
N/A
Yes.
N/A
3 6
3 - Main Entry Door
4 3 4
DRC Window Details Form 1a, 5/16/21 Page# ___ of ___
Building Elevation: _____________________
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration:
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Addition built ~ 1983; extruded
aluminum storefront system.
N/A
N/A
No.
Sill is rusted out and deteriorating.
Components of the extruded
aluminum storefront system can be
replaced in kind.
Replace sill in kind.
Yes.
Yes.
4 6
4 - Main Entry Sidelites
DRC Window Details Form 1, 5/16/21 Page# ___ of ___
Window Details Form
Instructions: Provide details and photos for EACH window replacement requested. Use additional pages of Form 1
or Form 1a as necessary. For ease of review, documentation should be categorized by façade. SEE EXAMPLE.
Building Elevation: _____________________ Insert photo above.
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration:
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Rear (East Elevation)
Addition built ~ 1983; painted
hollow core metal door.
Yes.
No.
No.
Wear due to deliveries.
Improve function and security.
Aluminum clad wood door. Refer to
drawings.
Yes.
Yes.
5 6
5 - Rear Door
5 6
DRC Window Details Form 1a, 5/16/21 Page# ___ of ___
Building Elevation: _____________________
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration:
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Details for Existing Window ID: Insert photo below showing existing condition.
Original window? If no, what
is the general replacement
date?
If operable, does the window
open? If no, why?
Storm window present? If
yes, what type?
Boarded up? If yes, is
window still in place?
Explanation of visible rot or
deterioration
Extenuating circumstances
requiring replacement vs.
repair
Proposed Replacement,
material and muntins:
Will trim and casing details
remain the same?
Is proposed window the same
size and same location as
original? Explain:
Addition built ~ 1983; vinyl
windows.
Yes.
No.
No.
N/A
Applicant wishes to provide interior
access to outdoor walk-in-cooler.
N/A
Trim to be removed.
N/A
6 6
6 - Rear Window
ENTRY DOORS
Dimensions & Specifications Guide
UNLIMITED POSSIBILITIES
TO CREATE YOUR ORIGINAL
E-SERIES
Architectural Collection
E-SERIES CASEMENT WINDOWS
FOR WINDOWS GREATER THAN 30 SQUARE FEET OR RATED HIGHER THAN PG50, ONE OF THESE THREE INSTALLATION METHODS IS REQUIRED:
A) THROUGH THE JAMB B) ALUMINUM INSTALLATION FLANGE OR C) INSTALLATION CLIPS.
ADDITIONAL CUSTOM SIZES ARE AVAILABLE. CONTACT YOUR LOCAL SUPPLIER FOR MORE INFORMATION. DRAWINGS ARE NOT TO SCALE.
R.O
.
F.S
.
1' 6 1/4"
1' 5 3/4"
1' 8 1/2"
1' 8"
2' 0 1/2"
2' 0"
2' 4 1/2"
2' 4"
2' 6 1/2"
2' 6"
2' 8 1/2"
2' 8"
3' 0 1/2"
3' 0"
2'
0
1/
2"
2'
0
"
2'
6
1/
2"
2'
6
"
2'
8
1/
2"
2'
8
"
3'
0
1/
2"
3'
0
"
3'
4
1/
2"
3'
4
"
4'
0
1/
2"
4'
0
"
4'
6
1/
2"
4'
6
"
5'
0
1/
2"
5'
0
"
5'
6
1/
2"
5'
6
"
6'
0
1/
2"
6'
0
"
CAX15 3/4 20 CAX1820 CAX2020
CAX15 3/4 26 CAX1826 CAX2026 CAX2426 CAX2626
CAX15 3/4 28 CAX1828 CAX2028 CAX2428 CAX2628 CAX2828
CAX15 3/4 30 CAX1830 CAX2030 CAX2430 CAX2630 CAX2830 CAX3030
CAX15 3/4 34 CAX1834 CAX2034 CAX2434 CAX2634 CAX2834 CAX3034
CAX15 3/4 40 CAX1840 CAX2040 CAX2440 ††CAX2640 †CAX2840 †CAX3040 †
CAX15 3/4 46 CAX1846 CAX2046 CAX2446 ††CAX2646 †CAX2846 †CAX3046 †
CAX15 3/4 50 CAX1850 CAX2050 CAX2450 ††CAX2650 †CAX2850 †CAX3050 *
CAX15 3/4 56 CAX1856 CAX2056 CAX2456 ††CAX2656 †CAX2856 *CAX3056 **
CAX15 3/4 60 CAX1860 CAX2060 CAX2460 ††CAX2660 †CAX2860 **CAX3060 **
CAX2420 CAX2620 CAX2820 CAX3020
CAX2826 CAX3026
CAX3028
Casement Window Sizes
2- Wide 3-Wide 4-Wide 5-Wide
Single UnitFrame Width RoughOpening Width Frame Width RoughOpening Width RoughOpening Width RoughOpening Width
1'-5 3/4"3'-0"2'-11 1/2" 4'-5 3/4"4'-5 1/4" 5'-11 1/2"5'-11"7'-5 1/4"7'-4 3/4"
1'-8"3'-4 1/2"3'-4"5'-0 1/2"5'-0"6'-8 1/2"6'-8"8'-4 1/2"8'-4"
2'-0"4'-0 1/2"4'-0"6'-0 1/2"6'-0"8'-0 1/2"8'-0"10'-0 1/2"10'-0"
2'-4"4'-8 1/2"4'-8"7'-0 1/2"7'-0"9'-4 1/2"9'-4"11 '-8 1/2"11 '-8"
2'-6"5'-0 1/2"5'-0"7'-6 1/2"7'-6"10'-0 1/2"10'-0"12'-6 1/2"12'-6"
2'-8"5'-4 1/2"5'-4"8'-0 1/2"8'-0"10'-8 1/2"10'-8"13'-4 1/2"13'-4"
3'-0"6'-0 1/2"6'-0"9'-0 1/2"9'-0"12'-0 1/2"12'-0"15'-0 1/2"15'-0"
FrameWidth FrameWidth FrameWidth
JoinedCasementCombinations
NOTES
† These units meet or exceed the following
dimensions: Clear Opening Area 5.7 sq. ft., Clear
Opening Width 20", Clear Opening Height 24" and
44" maximum floor to sill height (with standard
6' 10-1/2" structural header height).
†† Units meet the stated dimensions above when
optional hardware for widest clear opening is used.
* A sash-limiting device is standard on 2856 and
3050 casement units. See your local code official
for requirements in your area.
** A piano hinge and sash limiting device is standard
on 2860, 3056 and 3060 casement units.
If glass is positioned within 18" of the finished floor,
safety/tempered glass may be required. Local codes
may differ. Verify tempered glass requirements with
your local building code official.
Use structural joining material when necessary or
required by code.
The light patterns illustrated apply to rectangular
removable interior wood grilles, Full Divided Light,
Simulated Divided Light, Decorelle 100, 150 and 400
and Finelight™ Grilles-Between-the-Glass. All removable
interior wood grilles will be installed in the units
unless otherwise specified.
For a metric conversion in millimeters, multiply
dimensions in inches by 25.4.
FORMULA FOR COMBINATION WINDOWS
The overall frame dimension (both width and height)
is equal to the sum of the individual unit frame
dimensions plus joining material dimension(s).
The overall rough opening (both width and height) is
equal to the overall frame dimensions plus 1/4" on
all sides.
Any unit within each combination can be operating or
stationary.
Vent Layout as Viewed From Exterior
StationaryLeft Right
2020 E-Series Product Guide Page 1 of 5
5
*Visit andersenwindows.com/warranty for details.
Printing limitations prevent exact color duplication. Please see your Andersen supplier for actual color samples.
CUSTOM EXTERIORS OR
2-, 3- AND 4-TONE EXTERIORS
Choose a custom exterior color to get just the
right color for your design. And, with our 2-, 3-
and 4-tone color combinations, the sky’s the
limit. Mix and match up to four of our 50 exterior
colors for a combination look that’s all your own.
EXTERIOR TRIM
Choose exterior trim in either a flat
casing, brick mould or sill nosing profile
to add curb appeal to your home.
Light Bronze Medium
Bronze
Champagne Dark BronzeClear
Anodized
Copper Black
2" brick mould and 1 1/2" sill nose,
shown on a casement window
Colony white and black
7 ANODIZED FINISHES
Colony White White Abalone Balsa White Canvas Maple Syrup Harvest Gold
Pebble Tan Carmel Bourbon Acorn Coffee Bean
Aquamarine Patina Country Blue Blue Denim Caribbean
Blue
Slate
Sage Billiard Green Moss
Forest Green Sky Blue
Moody Blue
Sierra Bronze Dark Bronze
Mallard
Green
Watercolor
Blue
Smokey
Gray
Mystic Gray
FlagstonePrairie Grass Sandtone
Clay Canyon
Harbor Mist
Spearmint
Terratone Hot Chocolate Cocoa Bean
Fire Engine
Red
Cardinal Cinnamon
Toast
Bing Cherry OliveRed Rock
Stormy Blue Yorktown
Pewter
Dark AshDove Gray Black
DO YOU DREAM IN COLOR?
While our large selection of 50 exterior colors covers a lot of ground, inspiration comes in infinite hues. Let us match a paint
chip, a photograph or a favorite work of art to bring your dream color into the light of day. Or, choose from a selection of
anodized finishes for a rich, lustrous metallic appearance that cannot peel or flake and is not affected by sunlight.*
EXTERIOR COLORS
Design your window at
andersenwindows.com/design-tool
CHK'D BY:
DATE PRINTED:
OF
OF
DATE DRAWN:
SHEET:
BOX:
DRW#:
BY:
SCALE:
1
1/16/2026
1/14/2026
CMO
4
1
3/16" = 1'-0"
1
BA
L
Z
E
R
&
T
U
C
K
A
R
C
HI
T
E
C
T
U
R
E
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
FO
O
D
P
A
N
T
R
Y
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
1
26
-
I
B
-
2
9
3
7
1
.
0
0
.
0
1
-
0
0
Outdoor freezer/cooler combo
Vinyl NSF gasket (1/16" joint thickness), Cam-lock layout SN1
SPECIAL INSTRUCTIONS
Tamper-proof fasteners
Standard crating
WALL PANELS
Construction: 4" urethane (R-32)
Exterior Finish: 24 ga. galvanneal / 26 ga. stucco galvalume
Interior Finish: 26 ga. stucco galvalume
Ceiling connections: Camlock
Floor connections: Camlock
CEILING PANELS
Construction: 5 1/2" wood frame urethane (R-44)
Exterior Finish: Metal
Interior Finish: 26 ga. stucco galvalume
Ceiling Caps: No ceiling trim
Live Load: 195 psf
DOORS
[A]: 34" x 78" flush model G3 self-closing freezer door
*** TAMPER-PROOF FASTENERS ***
*** ELECTRICAL COMPONENTS PRE-WIRED ***
*** LEAF NOT RAISED FOR FLOORING ***
Brand: Imperial Brown
Frame: 4" high density urethane (R-32), 3-sided
w/ 26 ga. stucco galvalume both sides
w/ 24 ga. stainless steel 430 (magnetic) liners
w/ 4-sided heat cable in frame [FL-4-117W]
(24'-9" x 5 ohms/ft (124 total) @ 4.8 W/ft + Pepi - 120V, 1A)
Leaf: 4" thick, 3-side lap, standard height
w/ 26 ga. stucco galvalume both sides
w/ Magnetic gasket
w/ 2 1/4" black neoprene sweep
(3) Component Hardware #W59 spring assisted adjustable hinge
(1) Kason #27C cylinder locking deadbolt handle
(1) Kason #27C twist-off knob inside release
(1) Kason 'PUSH' pad
(1) Kason #1094 hydraulic door closer (polished chrome)
(1) Single pole toggle switch w/ pilot light (120V, 10A max. load) @ ext.
(1) 2" flush mount analog thermometer w/ 12" capillary
(1) Terminal J-Box @ int.
(1) Kason 1832 heated air vent (23W, 120V, .2A)
(1) .080 smooth aluminum threshold
[B]: 34" x 78" flush model G3 self-closing cooler door
*** TAMPER-PROOF FASTENERS ***
*** ELECTRICAL COMPONENTS PRE-WIRED ***
*** LEAF WILL NOT BE RAISED UNLESS SPECIFIED OTHERWISE ***
Brand: Imperial Brown
Frame: 4" high density urethane (R-32), 3-sided
w/ 26 ga. stucco galvalume both sides
w/ 24 ga. stainless steel 430 (magnetic) liners
Leaf: 4" thick, 3-side lap, standard height
w/ 26 ga. stucco galvalume both sides
w/ Magnetic gasket
w/ 2 1/4" black neoprene sweep
(3) Component Hardware #W59 spring assisted adjustable hinge
(1) Kason #27C cylinder locking deadbolt handle
(1) Kason #27C twist-off knob inside release
(1) Kason 'PUSH' pad
(1) Kason #1094 hydraulic door closer (polished chrome)
(1) Single pole toggle switch w/ pilot light (120V, 10A max. load) @ ext.
(1) 2" flush mount analog thermometer w/ 12" capillary
(1) Terminal J-Box @ int.
(1) .080 smooth aluminum threshold
PARTS
(2) ea. 4' LED light fixture #LED-440079 for cooler or freezer application (65W,
120-277V, 0.6-0.3A)-(Fixture ships loose for field installation.)
(37) ea. Prefabricated floor seismic restraint system-Simpson Titen or similar
concrete screws @ 24"o/c
(12) ea. Interior seismic tie-down @ ceiling level-(2" x 2") x 96" x 26 ga.
stucco galvalume
(1) Pkg. Sloped roof - Membrane roofing-Cut size: 17ft x 15ft - High end: 17ft
side - Rise: 2 in.w/ (1) roll Duro-Blue protective film
(Attaches to building on 12' - 0" side of box.) [QBRCS-168]
(1) Pkg. Sloped roof - ISO boards-[4 AA, 4 A, 4 B, 0 C, 0 Flat]
(6) ea. 'TB' membrane roofing trim, 96" long-24 ga. galvanneal
(2) ea. (2" x 4") x 96" x 24 ga. galvanneal outside corner vertical closure
(2) ea. (2" x 4") x 48" x 24 ga. galvanneal outside corner vertical closure
(2) ea. (2" x 4") x 96" x Stucco galvalume outside corner vertical closure
(2) ea. (2" x 4") x 48" x Stucco galvalume outside corner vertical closure
REFRIGERATION
(1) ea. Freezer - Outdoor R454a split system w/ EcoNET
9734 BTU/H @ 10.7F TD, 14.8 hr runtime @ -10F inside/95F outside room
90F @ cond. unit, 307ft altitude
(1) Russell R454a air cooled condensing unit #RFON250L4ADA-NT
208-230V/1ø/60Hz/2.5HP Scroll compressor
MCA=21, MOPD =35, AWEF: 3.15
39.875W x 28.25D x 21.25H x 240lbs.
(1) Russell R454a Next-Gen All-Temp evaporator model #RAL6E092DDARSF
w/ (2) DSE motors (1A) & electric defrost (9.8A)
208-230V/1ø/60Hz
43.625W x 15.5D x 18.125H x 50lbs.
Includes
(1) ea. Russell outside line check valve for Next-Gen All-Temp evaporators (1-4
fans)
(1) ea. Russell outside line solenoid valve for Next-Gen All-Temp evaporators
(1-4 fans)
(1) ea. Cooler - Outdoor R454a split system w/ EcoNET
7559 BTU/H @ 9.4F TD, 12.8 hr runtime @ 35F inside/95F outside room
90F @ cond. unit, 307ft altitude
(1) Russell R454a air cooled condensing unit #RFON060M4ADA-NT
208-230V/1ø/60Hz/0.5HP Scroll compressor
MCA=15, MOPD =15, AWEF: 7.6
27.875W x 28.25D x 18.75H x 195lbs.
(1) Russell R454a Next-Gen All-Temp evaporator model #RAL6A081ADARSF
w/ (1) DSE motors (0.8A) & air defrost
115V/1ø/60Hz
27.125W x 15.5D x 18.125H x 42lbs.
Includes
(1) ea. Russell outside line check valve for Next-Gen All-Temp evaporators (1-4
fans)
(1) ea. Russell outside line solenoid valve for Next-Gen All-Temp evaporators
(1-4 fans)
Meets 2009 Federal Energy Independence and Security Act Requirements.
STANDARD NOTES
To prevent condensation, a minimum 2" from the walk-in exterior surface is
required. High humidity conditions may require force ventilation in addition to
clearance.
Installation site floor must be true and level within 3/16" per 10' or additional
costs may be incurred.
R-Plus Doors sliding and vertical lift doors shall not be considered means of
egress. Check code egress requirements for your application.
ELECTRICAL
Field electrician to verify maximum acceptable load for light switches.If load is
too high, then relay type controls should be used.
After wiring devices, ALL conduits must be sealed to stop moisture transfer
through electrical raceways.
Failure to seal device per NEC codes WILL VOID WARRANTY.
NSF LABEL
N.S.F. LISTED (STD #7)
N.S.F. GASKET @ ALL PANEL JOINTS
R
- PRELIMINARY DRAWING -
Customer Note: This is a preliminary drawing only. Approving this drawing only
indicates that you agree with overall dimensions and door and opening locations.
Panel sizes and layout is subject to change. If "Nominal Size" has been quoted,
then actual dimensions may end up a bit smaller than drawn herein. Actual
dimensions will be shown on subsequent non-preliminary drawings. Should
discrepencies be found between drawing and sales order, customer may be
asked to approve standard Submittal drawings.
The customer or their repres entative in signing these drawings is taking
responsibility for overall size and fit around building walls, columns and ceiling
restrictions, door locations, openings for equipment supplied by others,
specifications and accessories listed.
APPROVED FOR FABRICATION WITH NO CHANGES
APPROVED FOR FABRICATION WITH CHANGES
REVISE AND RESUBMIT
Signature: ____________________________________________
22
1
/
8
W1
DC
45
1
5
/
1
6
W2
20
3
/
1
6
W3
39 11/16
W4
45 15/16
W5
11 3/411
3
/
4
W6
28
3
/
8
W7
45
1
5
/
1
6
W8
45
1
5
/
1
6
W9
11 3/4
11
3
/
4
W10
45 15/16
W11
39 11/16
W12
12 5/8
W13
DC 45 15/16
W14
11 3/4
11
3
/
4
W15
15
1
/
8
W1
6
45
1
5
/
1
6
W1
7
13
3
/
1
6
W1
8
11 3/411
3
/
4
W19
12 5/8
W20
45 15/16
W21
45
1
5
/
1
6
P
N
L
[A
]
45
1
5
/
1
6
P
N
L
[B
]
FREEZER COOLER
WALL PANELS
26 ga. stucco galvalume
24 ga. galvanneal
48
LC
96
LC
12
'
-
0
"
[
1
4
4
]
8'-0" [96]6'-0" [72]
14'-0" [168]
C1
26
1
3
/
1
6
97 1/2
P
C
C247
P
C
P
C347
P
C
P
C423
PP
SL
O
P
E
D
O
W
N
C5
70 7/16
C
C
C6
C
C
P
C7
C
C
P
C8C P
CEILING PANELS
F1
23
14
4
C
F2
47
CP
F3
27 3/8
PP
F4
23 3/8
CC
F5
47
P
FLOOR PANELS
4
1
/
4
W15
95
W16W17W18W19
95 95
5
1
/
2
8'
-
8
3
/
4
"
[
1
0
4
3
/
4
]
ELEVATION
W12
95
W1W2W3W4
95
ELEVATION
3 1/2" high density urethane (R-28)
4" high density urethane (R-32)
4" urethane (R-32)
5 1/2" wood frame urethane (R-44)
CONSTRUCTION LEGEND:
48
50
1
/
8
Bu
i
l
d
i
n
g
o
p
e
n
i
n
g
[A]
Backing @ int.
for strip curtain
S
HVJ
[B]
Backing @ int.
for strip curtain
S
HV
J
8'
-
1
0
3
/
4
"
[
1
0
6
3
/
4
]
2
CHK'D BY:
DATE PRINTED:
OF
OF
DATE DRAWN:
SHEET:
BOX:
DRW#:
BY:
SCALE:
2
1/16/2026
1/14/2026
CMO
4
1
3/16" = 1'-0"
1
BA
L
Z
E
R
&
T
U
C
K
A
R
C
HI
T
E
C
T
U
R
E
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
FO
O
D
P
A
N
T
R
Y
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
2
26
-
I
B
-
2
9
3
7
1
.
0
0
.
0
1
-
0
0
4
1
/
4
95
5
1
/
2
8'
-
8
3
/
4
"
[
1
0
4
3
/
4
]
8'
-
1
0
3
/
4
"
[
1
0
6
3
/
4
]
2
VERTICAL CLOSURES
Building Wall
Walk-In Wall
Building Wall
Walk-In Wall
4
2
#8 x 1/2" MTHSMS @ 12"#8 x 1/2" MTHSMS @ 12"
#8 x 1/2" MTHSMS @ 12"
4
2" Air Space2" Air Space
MEMBRANE ROOFING
Attached to Building, 'TB' Facia Trim
Caulk with sealant
(by others than manufacturer)
Building wall
Termination bar
2" Air Gap
Ceiling panel
Wall panel
10
9
3
/
4
"NSF" stamp both edges
of the retainer strip
"Open" hem w/ 1/2" lips
TYP. both edges
Duro-Last
membrane roofing
Polyurethane tapered
ISO boards (4' x 4' sheets)
12"
1/8"
1/
2
'TB' trim corner
(2) #8 x 12" MTHSMS ea. leg
'TB' trim (slide over retainer strip)
'TB' retainer strip, pre-punched
TRIM CORNER DETAIL
NOTES:
-Membrane roofing to be installed by Duro-Last
approved installers or roofing warranty will be void.
-Do not fasten retainer strip into ISO boards
'TB' trim over 24 ga. smooth galv. retainer strip
w/ (2) ea. #10 x 11 2" PHSMS @ 12" O/C
EXT.INT.
Wall panel
Wear surface
1/
2
3
1
/
2
1/2" Underlayment
2" x 2" x 16 ga. galv. angle
w/ 3/8" x 3" concrete seismic screw anchor
@ 24" o/c into floor (min. embed 2 1/2") (4" min. concrete)
4
1
/
4
Concrete slab
(By others than IB)
Counter sink to base angle and drill
base angle in field for anchors,
free foam after inspection
3 1/2" HTFN FLOOR
with Concealed Tie-Down
2" x 2" x cont.
w/ #8 x 1/2" MTHSMS @ 12" o/c @ ea. leg
w/ (4) ea. #8 @ splices @ ea. leg
1 1
SPLICE DETAIL
11 1
5
Minimum Overlap
Ceiling panel
Wall panel
Camlocks @ 24" o/c
CEILING TIE-DOWN
CHK'D BY:
DATE PRINTED:
OF
OF
DATE DRAWN:
SHEET:
BOX:
DRW#:
BY:
SCALE:
3
1/16/2026
1/14/2026
CMO
4
1
3/16" = 1'-0"
1
BA
L
Z
E
R
&
T
U
C
K
A
R
C
HI
T
E
C
T
U
R
E
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
FO
O
D
P
A
N
T
R
Y
SA
R
A
T
O
G
A
S
P
R
I
N
G
S
,
N
Y
3
26
-
I
B
-
2
9
3
7
1
.
0
0
.
0
1
-
0
0
www.Imperial-Brown.com | Sales@Imperial-Brown.com
Stucco Aluminum Stucco Galvanized
Stucco Black Galv.
Available Metal and Other Finishes
Smooth Sandstone
www.Imperial-Brown.com | Sales@Imperial-Brown.com
East Coast Factory
209 Long Meadow Drive
Salisbury, NC 28147
Local (704) 636-5131
Toll Free (800) 438-2316
West Coast Factory
198 SE 223rd Ave.
Gresham, OR 97030
Local (503) 665-5539
Toll Free (800) 238-4093
Midwest Factory
2115 W. Main Street
Prague, OK 74864
Local (405) 567-1960
Toll Free (800) 238-4093
Available Metal and Other Finishes
Stucco White Galv.Galvanneal
Smooth Stainless Steel Stucco Galvalume