HomeMy WebLinkAbout20260089 67 West Ave Saratoga Integrity Auto LLc Site Plan Review Revised Plans 03.02.2026ELECTRIC METERS
LA
N
D
S
C
A
P
E
LA
N
D
S
C
A
P
E
LA
N
D
S
C
A
P
E
LA
N
D
S
C
A
P
E
CONC
ASPHALT
PARKING
AREA
WE
S
T
A
V
E
CONC
WOODED
WOODED
WOODED
RAMP W/
RAILINGS
ASPHALT
PARKING
AREA
LANDS N/F OF
INTRADA SARATOGA SPRINGS, HOUSING DEVELOPMENT
SBL: 165.-2-72.12
LANDS N/F OF
UNITED STATES POSTAL SERVICE
SBL: 165.-2-72.11
LANDS N/F OF
81 WEST REALITY INC
SBL: 165.-2-15
TENANT 2
(CURRENTLY VACANT)
TENANT 1
(CAR SALE SHOP)
(B- BUSINESS OCCUPANCY)
AWNING
WALL PAK HALOGEN
AREA LIGHT (ABOVE
AWNING)
LP TANKS ON
CONCRETE PADS
LED OVERHEAD LIGHT
CONCRETE RETAINING WALL
W/ STEEL RAILING
FLUSH RETAINING WALL
W/ STEEL RAILINGASPHALT WALK WAY
LOADING DOCK
WALL PAK HALOGEN
AREA LIGHT (ABOVE
OVERHEAD DOOR)
WALL A/C UNIT, TYP.
ASPHALT
PARKING
AREA
12
'
B
U
I
L
D
-
T
O
LI
N
E
LANDS N/F OF
LAREAU, ALEXEI
SBL: 165.-14-1-37
LANDS N/F OF
JENNINGS, BRENDA J
SBL: 165.-14-1-38
LANDS N/F OF
68 WEST AVENUE LLC
SBL: 165.-14-1-39
LANDS N/F OF
LOOKOUT SARATOGA LLC
SBL: 165.-14-1-40
5'-2"
41
'
-
8
"
70'-7"
12
9
'
-
1
0
"
9'
-
0
"
18'-0"
24
'
-
0
"
APPROVAL:
Zoning Information Table
Site Statistics
Tax Map No.165.-2-85
Town Zoning District:T-5 NEIGHBORHOOD CENTER
Parcel Areas:1.27AC
Number of Lots:1
Town/APA Zoning Analysis Required Proposed
Minimum Lot Depth:0' TO 12'5'
Maximum Building Height:40 ft 23'-7"
Maximum Stories per Building 2 2
Setbacks:
Lot Line Abutting Any Public
Right-Of-Way:
0'-12' Build-To
Zone (min)5'-2"
Rear:0ft (min)70'-7"
Side:0ft (min)129'-10" (North)
41'-8" (South)
Parking Analysis Required Proposed
Minimum Parking Spots:(1)per 500sf of
Interior Space
5 Spots (2371sf of
Interior space)
A.V.
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
SHT. NO.K.B.
NO.DATE BYDESCRIPTION
REVISIONS:
OF
PROJECT NO.
DWG. NO.
KB ENGINEERING & CONSULTING PLLC
THESE PLANS SHOW KNOWN SUBSURFACE STRUCTURES, ABOVE-GROUND STRUCTURES AND/OR UTILITIES
BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATION OF WHICH MAY VARY FROM THE
LOCATIONS INDICATED. IN PARTICULAR, THE CONTRACTOR IS WARNED THAT THE EXACT OR EVEN
APPROXIMATE LOCATION OF SUCH PIPELINES, SUBSURFACE STRUCTURES AND/OR UTILITIES IN THE AREA
MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN AT ALL. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. THE CONTRACTOR SHALL
CONTACT U.F.P.O. AT 1-800-962-7962 48 HOURS PRIOR TO ANY EXCAVATION OPERATIONS. CONTRACTOR
SHALL BE RESPONSIBLE TO CONDUCT EXPLORATORY TESTS PITS AS MAY BE REQUIRED TO DETERMINE
UNDERGROUND CONDITIONS, THE COST OF WHICH SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THIS
CONTRACT. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
105 Lakehill Road ~ Suite 2 ~ PO Box 210
Burnt Hills, NY 12027
Phone: (518) 280-0046
www.kbengineeringandconsulting.com
CITY OF SARATOGA SPRINGS
JANUARY 5, 2026
SITUATE IN :
CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, STATE OF NEW YORK
LANDS N/F 67 WEST AVENUE LLC
67 WEST AVE
SBL 165.-2-85
25062
3
1 01/29/26 KBPER SPR CHECK LIST
2 02/18/26 AVADDED PARKING- PER TOWN COMMENT
C-101
1
SITE PLAN
EXISTING CONDITIONS
NOTES:
1. THIS SITE PLAN APPROVED FOR SPECIAL USE PERMIT #20250674 EXTENSION ON 10/24/2025.
1/16" = 1'
SITE LOCATION MAP
APPLICANTS:
67 WEST AVENUE LLC
c/o JEAN PIERRE LAREAU
74 WEST AVE
SARATOGA SPRINGS, NY 12866
PHONE: (518) 817-1896 / (518) 669-8052
SITE
MAP REFERENCE:
1. SITE PLAN DERIVED FROM SARATOGA COUNTY GIS MAPPER.
2. TENANT 1 SPACE EXISTING CONDITIONS SURVEYED AND RECORDED HERE IN BY
KB ENGINEERING & CONSULTING, PLLC ON DECEMBER 23, 2025.
N
EXISTING SITE CONDITIONS
SCALE: 1/16"=1'
7'
-
0
"
C
L
G
7'-7" CLG
8'-2" CLG
8'
-
1
0
"
C
L
G
13'-1" CLG
12
'
-
0
"
C
L
G
9'
-
0
"
C
L
G
10'-10" W X 10'-9" HIGH
8'-5" W X 7'-1" HIGH
7'-0" CLG
8'
-
1
0
"
C
L
G
8'
-
1
0
"
C
L
G
3
E
3
A
3
D
3
C
3
B
EXTERIOR WALL LIGHT
DUPLEX OUTLET
HOSE BIBB
SINK
TOILET
EMERGENCY LIGHT w/ LIGHTED EXIT SIGN
FIRE EXTINGUISHER
QUADRUPLEX OUTLET
WALL MOUNT CAMERA
LIGHT SWITCH
DATA/INTERNET JACK
10.5X12.5 ATTIC TRUSSES@24"O.C.TYP.
MAIN AREA
CONCRETE FLOOR
SECONDARY AREA
CONCRETE FLOOR
BATHROOM
LVP FLOORING
ELECTRICAL PANEL - WALL MOUNTED
SMOKE ALARM
WALL MOUNTED SMOKE ALARM
AWNING
(WOODEN FRAME)
CEILING LIGHT (LED/ FLUORESCENT)
CEILING-MOUNTED FIXTURE
25
'
-
3
"
8'
-
0
"
8'
-
5
"
7'-4"
30'-8"
30'-0"
25
'
-
1
"
15'-4"
8'-5"
58
'
-
1
1
"
3'
-
1
0
"
7'
-
5
"
11
"
14
'
-
6
"
11
"
6'
-
2
"
33
'
-
1
0
"
15'-4"14'-0"10'-10"14'-0"
23'-2"
15
'
-
7
"
39'-7"
TENANT 2 SPACE
WA
L
L
MO
U
N
T
E
D
HE
A
T
E
R
WA
L
L
MO
U
N
T
E
D
HE
A
T
E
R
WALL
MOUNTED
HEATER
EXTERIOR
WALL A/C UNIT
2'X4' NON BEARING WALLS W/ PLYWOOD ON TENANT 1 SIDE (TYP)
2'
X
6
'
E
X
T
E
R
I
O
R
W
A
L
L
S
W
/
P
L
Y
W
O
O
D
I
N
T
E
R
I
O
R
,
B
A
T
I
N
S
U
L
A
T
I
O
N
,
M
E
T
A
L
S
H
E
E
T
I
N
G
E
X
T
E
R
I
O
R
APPROVAL:
SITE LOCATION MAP
APPLICANTS:
SITE
A.V.
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
SHT. NO.K.B.
NO.DATE BYDESCRIPTION
REVISIONS:
OF
PROJECT NO.
DWG. NO.
KB ENGINEERING & CONSULTING PLLC
THESE PLANS SHOW KNOWN SUBSURFACE STRUCTURES, ABOVE-GROUND STRUCTURES AND/OR UTILITIES
BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATION OF WHICH MAY VARY FROM THE
LOCATIONS INDICATED. IN PARTICULAR, THE CONTRACTOR IS WARNED THAT THE EXACT OR EVEN
APPROXIMATE LOCATION OF SUCH PIPELINES, SUBSURFACE STRUCTURES AND/OR UTILITIES IN THE AREA
MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN AT ALL. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. THE CONTRACTOR SHALL
CONTACT U.F.P.O. AT 1-800-962-7962 48 HOURS PRIOR TO ANY EXCAVATION OPERATIONS. CONTRACTOR
SHALL BE RESPONSIBLE TO CONDUCT EXPLORATORY TESTS PITS AS MAY BE REQUIRED TO DETERMINE
UNDERGROUND CONDITIONS, THE COST OF WHICH SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THIS
CONTRACT. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
105 Lakehill Road ~ Suite 2 ~ PO Box 210
Burnt Hills, NY 12027
Phone: (518) 280-0046
www.kbengineeringandconsulting.com
CITY OF SARATOGA SPRINGS
JANUARY 5, 2026
SITUATE IN :
CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, STATE OF NEW YORK
LANDS N/F 67 WEST AVENUE LLC
67 WEST AVE
SBL 165.-2-85
25062
3
1 01/29/26 KBPER SPR CHECK LIST
2 02/18/26 AVADDED PARKING- PER TOWN COMMENT
C-102
2
EXISTING FLOOR PLAN- TENANT 1 SPACE
1/4" = 1'
MAP REFERENCE:
1. SITE PLAN DERIVED FROM SARATOGA COUNTY GIS MAPPER.
2. TENANT 1 SPACE EXISTING CONDITIONS SURVEYED AND RECORDED HERE IN BY
KB ENGINEERING & CONSULTING, PLLC ON DECEMBER 23, 2025.
67 WEST AVENUE LLC
c/o JEAN PIERRE LAREAU
74 WEST AVE
SARATOGA SPRINGS, NY 12866
PHONE: (518) 817-1896
NOTES:
1. TENANT 1 SPACE IS CURRENTLY USED FOR A COMMERCIAL CAR SALES BUSINESS. (B-BUSINESS OCCUPANCY)
EXISTING FLOOR PLAN
SCALE: 1/4"=1'
WALL PAK HALOGEN
LIGHT FIXTURE
METAL SIDING
METAL SIDING
AIR
CONDITIONER
METAL SIDING
OVERHEAD
DOOR
METAL ROOF
METAL ROOF
METAL SIDING METAL SIDING
METAL ROOF
DOOR
SHINGLE
ROOF
CMU
LIGHT FIXTURE
OUTLET
A
SCALE: 3/16" = 1'
NORTH ELEVATION B
SCALE: 3/16" = 1'
SOUTH ELEVATION
C
SCALE: 3/16" = 1'
WEST ELEVATION D
SCALE: 3/16" = 1'
EAST ELEVATION
E
SCALE: 3/16" = 1'
SECTION A
MAIN AREA
SECONDARY AREA
BATHROOM
OVERHEAD
DOOR
10
'
-
0
"
23
'
-
7
"
10
'
-
4
"
13
'
-
1
0
"
7'
-
1
"
8'-5"
11'-4"
10'-2"
11'-4"
23'-2"
7'
-
1
0
"
8'
-
1
0
"
10
'
-
4
"
13
'
-
1
0
"
23
'
-
7
"
7'
-
0
"
3'-2"
13
'
-
1
0
"
23
'
-
7
"
8'-11"
3'-0"
7'
-
0
"
13
'
-
1
"
12
'
-
0
"
9'
-
3
"
15'-4"38'-11"
9'
-
6
"
APPROVAL:
A.V.
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
SHT. NO.K.B.
NO.DATE BYDESCRIPTION
REVISIONS:
OF
PROJECT NO.
DWG. NO.
KB ENGINEERING & CONSULTING PLLC
THESE PLANS SHOW KNOWN SUBSURFACE STRUCTURES, ABOVE-GROUND STRUCTURES AND/OR UTILITIES
BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATION OF WHICH MAY VARY FROM THE
LOCATIONS INDICATED. IN PARTICULAR, THE CONTRACTOR IS WARNED THAT THE EXACT OR EVEN
APPROXIMATE LOCATION OF SUCH PIPELINES, SUBSURFACE STRUCTURES AND/OR UTILITIES IN THE AREA
MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN AT ALL. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. THE CONTRACTOR SHALL
CONTACT U.F.P.O. AT 1-800-962-7962 48 HOURS PRIOR TO ANY EXCAVATION OPERATIONS. CONTRACTOR
SHALL BE RESPONSIBLE TO CONDUCT EXPLORATORY TESTS PITS AS MAY BE REQUIRED TO DETERMINE
UNDERGROUND CONDITIONS, THE COST OF WHICH SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THIS
CONTRACT. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
105 Lakehill Road ~ Suite 2 ~ PO Box 210
Burnt Hills, NY 12027
Phone: (518) 280-0046
www.kbengineeringandconsulting.com
CITY OF SARATOGA SPRINGS
JANUARY 5, 2026
SITUATE IN :
CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, STATE OF NEW YORK
LANDS N/F 67 WEST AVENUE LLC
67 WEST AVE
SBL 165.-2-85
25062
3
1 01/29/26 KBPER SPR CHECK LIST
2 02/18/26 AVADDED PARKING- PER TOWN COMMENT
C-103
3
EXISTING ELEVATIONS & SECTIONS
3/16" = 1'
MAP REFERENCE:
1. SITE PLAN DERIVED FROM SARATOGA COUNTY GIS MAPPER.
2. TENANT 1 SPACE EXISTING CONDITIONS SURVEYED AND RECORDED HERE IN BY
KB ENGINEERING & CONSULTING, PLLC ON DECEMBER 23, 2025.