Loading...
HomeMy WebLinkAbout20260089 67 West Ave Saratoga Integrity Auto LLc Site Plan Review Revised Plans 03.02.2026ELECTRIC METERS LA N D S C A P E LA N D S C A P E LA N D S C A P E LA N D S C A P E CONC ASPHALT PARKING AREA WE S T A V E CONC WOODED WOODED WOODED RAMP W/ RAILINGS ASPHALT PARKING AREA LANDS N/F OF INTRADA SARATOGA SPRINGS, HOUSING DEVELOPMENT SBL: 165.-2-72.12 LANDS N/F OF UNITED STATES POSTAL SERVICE SBL: 165.-2-72.11 LANDS N/F OF 81 WEST REALITY INC SBL: 165.-2-15 TENANT 2 (CURRENTLY VACANT) TENANT 1 (CAR SALE SHOP) (B- BUSINESS OCCUPANCY) AWNING WALL PAK HALOGEN AREA LIGHT (ABOVE AWNING) LP TANKS ON CONCRETE PADS LED OVERHEAD LIGHT CONCRETE RETAINING WALL W/ STEEL RAILING FLUSH RETAINING WALL W/ STEEL RAILINGASPHALT WALK WAY LOADING DOCK WALL PAK HALOGEN AREA LIGHT (ABOVE OVERHEAD DOOR) WALL A/C UNIT, TYP. ASPHALT PARKING AREA 12 ' B U I L D - T O LI N E LANDS N/F OF LAREAU, ALEXEI SBL: 165.-14-1-37 LANDS N/F OF JENNINGS, BRENDA J SBL: 165.-14-1-38 LANDS N/F OF 68 WEST AVENUE LLC SBL: 165.-14-1-39 LANDS N/F OF LOOKOUT SARATOGA LLC SBL: 165.-14-1-40 5'-2" 41 ' - 8 " 70'-7" 12 9 ' - 1 0 " 9' - 0 " 18'-0" 24 ' - 0 " APPROVAL: Zoning Information Table Site Statistics Tax Map No.165.-2-85 Town Zoning District:T-5 NEIGHBORHOOD CENTER Parcel Areas:1.27AC Number of Lots:1 Town/APA Zoning Analysis Required Proposed Minimum Lot Depth:0' TO 12'5' Maximum Building Height:40 ft 23'-7" Maximum Stories per Building 2 2 Setbacks: Lot Line Abutting Any Public Right-Of-Way: 0'-12' Build-To Zone (min)5'-2" Rear:0ft (min)70'-7" Side:0ft (min)129'-10" (North) 41'-8" (South) Parking Analysis Required Proposed Minimum Parking Spots:(1)per 500sf of Interior Space 5 Spots (2371sf of Interior space) A.V. DRAWN BY: CHECKED BY: DATE: SCALE: SHT. NO.K.B. NO.DATE BYDESCRIPTION REVISIONS: OF PROJECT NO. DWG. NO. KB ENGINEERING & CONSULTING PLLC THESE PLANS SHOW KNOWN SUBSURFACE STRUCTURES, ABOVE-GROUND STRUCTURES AND/OR UTILITIES BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATION OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR, THE CONTRACTOR IS WARNED THAT THE EXACT OR EVEN APPROXIMATE LOCATION OF SUCH PIPELINES, SUBSURFACE STRUCTURES AND/OR UTILITIES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN AT ALL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. THE CONTRACTOR SHALL CONTACT U.F.P.O. AT 1-800-962-7962 48 HOURS PRIOR TO ANY EXCAVATION OPERATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO CONDUCT EXPLORATORY TESTS PITS AS MAY BE REQUIRED TO DETERMINE UNDERGROUND CONDITIONS, THE COST OF WHICH SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THIS CONTRACT. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 105 Lakehill Road ~ Suite 2 ~ PO Box 210 Burnt Hills, NY 12027 Phone: (518) 280-0046 www.kbengineeringandconsulting.com CITY OF SARATOGA SPRINGS JANUARY 5, 2026 SITUATE IN : CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, STATE OF NEW YORK LANDS N/F 67 WEST AVENUE LLC 67 WEST AVE SBL 165.-2-85 25062 3 1 01/29/26 KBPER SPR CHECK LIST 2 02/18/26 AVADDED PARKING- PER TOWN COMMENT C-101 1 SITE PLAN EXISTING CONDITIONS NOTES: 1. THIS SITE PLAN APPROVED FOR SPECIAL USE PERMIT #20250674 EXTENSION ON 10/24/2025. 1/16" = 1' SITE LOCATION MAP APPLICANTS: 67 WEST AVENUE LLC c/o JEAN PIERRE LAREAU 74 WEST AVE SARATOGA SPRINGS, NY 12866 PHONE: (518) 817-1896 / (518) 669-8052 SITE MAP REFERENCE: 1. SITE PLAN DERIVED FROM SARATOGA COUNTY GIS MAPPER. 2. TENANT 1 SPACE EXISTING CONDITIONS SURVEYED AND RECORDED HERE IN BY KB ENGINEERING & CONSULTING, PLLC ON DECEMBER 23, 2025. N EXISTING SITE CONDITIONS SCALE: 1/16"=1' 7' - 0 " C L G 7'-7" CLG 8'-2" CLG 8' - 1 0 " C L G 13'-1" CLG 12 ' - 0 " C L G 9' - 0 " C L G 10'-10" W X 10'-9" HIGH 8'-5" W X 7'-1" HIGH 7'-0" CLG 8' - 1 0 " C L G 8' - 1 0 " C L G 3 E 3 A 3 D 3 C 3 B EXTERIOR WALL LIGHT DUPLEX OUTLET HOSE BIBB SINK TOILET EMERGENCY LIGHT w/ LIGHTED EXIT SIGN FIRE EXTINGUISHER QUADRUPLEX OUTLET WALL MOUNT CAMERA LIGHT SWITCH DATA/INTERNET JACK 10.5X12.5 ATTIC TRUSSES@24"O.C.TYP. MAIN AREA CONCRETE FLOOR SECONDARY AREA CONCRETE FLOOR BATHROOM LVP FLOORING ELECTRICAL PANEL - WALL MOUNTED SMOKE ALARM WALL MOUNTED SMOKE ALARM AWNING (WOODEN FRAME) CEILING LIGHT (LED/ FLUORESCENT) CEILING-MOUNTED FIXTURE 25 ' - 3 " 8' - 0 " 8' - 5 " 7'-4" 30'-8" 30'-0" 25 ' - 1 " 15'-4" 8'-5" 58 ' - 1 1 " 3' - 1 0 " 7' - 5 " 11 " 14 ' - 6 " 11 " 6' - 2 " 33 ' - 1 0 " 15'-4"14'-0"10'-10"14'-0" 23'-2" 15 ' - 7 " 39'-7" TENANT 2 SPACE WA L L MO U N T E D HE A T E R WA L L MO U N T E D HE A T E R WALL MOUNTED HEATER EXTERIOR WALL A/C UNIT 2'X4' NON BEARING WALLS W/ PLYWOOD ON TENANT 1 SIDE (TYP) 2' X 6 ' E X T E R I O R W A L L S W / P L Y W O O D I N T E R I O R , B A T I N S U L A T I O N , M E T A L S H E E T I N G E X T E R I O R APPROVAL: SITE LOCATION MAP APPLICANTS: SITE A.V. DRAWN BY: CHECKED BY: DATE: SCALE: SHT. NO.K.B. NO.DATE BYDESCRIPTION REVISIONS: OF PROJECT NO. DWG. NO. KB ENGINEERING & CONSULTING PLLC THESE PLANS SHOW KNOWN SUBSURFACE STRUCTURES, ABOVE-GROUND STRUCTURES AND/OR UTILITIES BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATION OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR, THE CONTRACTOR IS WARNED THAT THE EXACT OR EVEN APPROXIMATE LOCATION OF SUCH PIPELINES, SUBSURFACE STRUCTURES AND/OR UTILITIES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN AT ALL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. THE CONTRACTOR SHALL CONTACT U.F.P.O. AT 1-800-962-7962 48 HOURS PRIOR TO ANY EXCAVATION OPERATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO CONDUCT EXPLORATORY TESTS PITS AS MAY BE REQUIRED TO DETERMINE UNDERGROUND CONDITIONS, THE COST OF WHICH SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THIS CONTRACT. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 105 Lakehill Road ~ Suite 2 ~ PO Box 210 Burnt Hills, NY 12027 Phone: (518) 280-0046 www.kbengineeringandconsulting.com CITY OF SARATOGA SPRINGS JANUARY 5, 2026 SITUATE IN : CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, STATE OF NEW YORK LANDS N/F 67 WEST AVENUE LLC 67 WEST AVE SBL 165.-2-85 25062 3 1 01/29/26 KBPER SPR CHECK LIST 2 02/18/26 AVADDED PARKING- PER TOWN COMMENT C-102 2 EXISTING FLOOR PLAN- TENANT 1 SPACE 1/4" = 1' MAP REFERENCE: 1. SITE PLAN DERIVED FROM SARATOGA COUNTY GIS MAPPER. 2. TENANT 1 SPACE EXISTING CONDITIONS SURVEYED AND RECORDED HERE IN BY KB ENGINEERING & CONSULTING, PLLC ON DECEMBER 23, 2025. 67 WEST AVENUE LLC c/o JEAN PIERRE LAREAU 74 WEST AVE SARATOGA SPRINGS, NY 12866 PHONE: (518) 817-1896 NOTES: 1. TENANT 1 SPACE IS CURRENTLY USED FOR A COMMERCIAL CAR SALES BUSINESS. (B-BUSINESS OCCUPANCY) EXISTING FLOOR PLAN SCALE: 1/4"=1' WALL PAK HALOGEN LIGHT FIXTURE METAL SIDING METAL SIDING AIR CONDITIONER METAL SIDING OVERHEAD DOOR METAL ROOF METAL ROOF METAL SIDING METAL SIDING METAL ROOF DOOR SHINGLE ROOF CMU LIGHT FIXTURE OUTLET A SCALE: 3/16" = 1' NORTH ELEVATION B SCALE: 3/16" = 1' SOUTH ELEVATION C SCALE: 3/16" = 1' WEST ELEVATION D SCALE: 3/16" = 1' EAST ELEVATION E SCALE: 3/16" = 1' SECTION A MAIN AREA SECONDARY AREA BATHROOM OVERHEAD DOOR 10 ' - 0 " 23 ' - 7 " 10 ' - 4 " 13 ' - 1 0 " 7' - 1 " 8'-5" 11'-4" 10'-2" 11'-4" 23'-2" 7' - 1 0 " 8' - 1 0 " 10 ' - 4 " 13 ' - 1 0 " 23 ' - 7 " 7' - 0 " 3'-2" 13 ' - 1 0 " 23 ' - 7 " 8'-11" 3'-0" 7' - 0 " 13 ' - 1 " 12 ' - 0 " 9' - 3 " 15'-4"38'-11" 9' - 6 " APPROVAL: A.V. DRAWN BY: CHECKED BY: DATE: SCALE: SHT. NO.K.B. NO.DATE BYDESCRIPTION REVISIONS: OF PROJECT NO. DWG. NO. KB ENGINEERING & CONSULTING PLLC THESE PLANS SHOW KNOWN SUBSURFACE STRUCTURES, ABOVE-GROUND STRUCTURES AND/OR UTILITIES BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATION OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR, THE CONTRACTOR IS WARNED THAT THE EXACT OR EVEN APPROXIMATE LOCATION OF SUCH PIPELINES, SUBSURFACE STRUCTURES AND/OR UTILITIES IN THE AREA MAY BE DIFFERENT FROM THAT SHOWN OR MAY NOT BE SHOWN AT ALL. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROCEED WITH GREAT CARE IN EXECUTING ANY WORK. THE CONTRACTOR SHALL CONTACT U.F.P.O. AT 1-800-962-7962 48 HOURS PRIOR TO ANY EXCAVATION OPERATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO CONDUCT EXPLORATORY TESTS PITS AS MAY BE REQUIRED TO DETERMINE UNDERGROUND CONDITIONS, THE COST OF WHICH SHALL BE INCLUDED IN THE VARIOUS ITEMS IN THIS CONTRACT. EXISTING UTILITIES DAMAGED BY THE CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 105 Lakehill Road ~ Suite 2 ~ PO Box 210 Burnt Hills, NY 12027 Phone: (518) 280-0046 www.kbengineeringandconsulting.com CITY OF SARATOGA SPRINGS JANUARY 5, 2026 SITUATE IN : CITY OF SARATOGA SPRINGS, SARATOGA COUNTY, STATE OF NEW YORK LANDS N/F 67 WEST AVENUE LLC 67 WEST AVE SBL 165.-2-85 25062 3 1 01/29/26 KBPER SPR CHECK LIST 2 02/18/26 AVADDED PARKING- PER TOWN COMMENT C-103 3 EXISTING ELEVATIONS & SECTIONS 3/16" = 1' MAP REFERENCE: 1. SITE PLAN DERIVED FROM SARATOGA COUNTY GIS MAPPER. 2. TENANT 1 SPACE EXISTING CONDITIONS SURVEYED AND RECORDED HERE IN BY KB ENGINEERING & CONSULTING, PLLC ON DECEMBER 23, 2025.