Loading...
HomeMy WebLinkAbout20251051 162 Circular St. RISE Exterior Modifications Plans (2)ACCESACOUSAC TAD ADJAFF ALTALUMANOD ASPHASSOC BALC B/CBDBETBLDGBLKGBM(S)BOTBRGBRKBRKTBSMT BUS CCAB CBCICJ CLGCLLCLOSCLRCMUCOCOLCONCCOND CONNCONSTCONTCONTRCOORDCORRCPTCRSCTCWCWR ACCESSIBLE ACOUSTICAL CEILING TILEAREA DRAIN, ACCESS DOOR ADJACENTABOVE FINISHED FLOOR ALTERNATEALUMINUMANODIZED FINISH ASPHALTASSOCIATED BALCONY BOTTOM OF CURBBOARDBETWEENBUILDINGBLOCKINGBEAM(S)BOTTOMBEARINGBRICKBRACKETBASEMENT BUSINESS CONDUITCABINET CATCH BASINCAST IRONCONTROL JOINT CEILINGCONTRACT LIMIT LINECLOSETCLEAR(ANCE)CONCRETE MASONRY UNITCLEAN OUTCOLUMNCONCRETECONDENS(ATE, ER, ING, ATION) CONNECTIONCONSTRUCTIONCONTINU(OUS, ATION)CONTRACTORCOORDINATECORRIDORCARPETCOURSECERAMIC TILECOLD WATERCHILLED WATER RETURN ACOUSTICAL D DBLDEMODEPTDETDFDIDIADIAGDIMDISP DLDNDOMDRDWDWG EA EFEHDEIFSEJELELECELEVEMERENCLEPEPDM EQEQPTETRETRDETRLEW EWCEXHEXISTEXPEXT FAIFBFDFDNFEFECFFFHFIN FL, FLRFLUOR FO FOBFOCFOUND FPWHF.R.P.FRT DRAIN DOUBLEDEMOLISHDEPARTMENTDETAILDRINKING FOUNTAINDUCTILE IRON, DROP INLETDIAMETERDIAGONALDIMENSIONDISPENSER DEAD LOADDOWNDOMESTICDOORDISHWASHERDRAWING EACH EXHAUST FANELECTRIC HAND DRYEREXTERIOR INSULATION & FINISH SYSTEMEXPANSION JOINTELEVATIONELECTRICALELEVATOREMERGENCYENCLOS(E, SURE)ELECTRICAL PANEL BOARDETHYLENE PROPYLENE DIENE MONOMER EQUALEQUIPMENTEXISTING TO REMAINEXISTING TO BE REMOVEDEXISTING TO BE RELOCATEDEACH WAY ELECTRIC WATER COOLEREXHAUSTEXISTINGEXPOSEDEXTERIOR FRESH AIR INTAKEFOILBACKEDFLOOR DRAIN, FIRE DAMPERFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFINISHED FLOORFIRE HYDRANTFINISH(ED) FLOORFLUORESCENT FIBER OPTIC FACE OF BRICKFACE OF CONCRETEFOUNDATION FREEZE PROOF WALL HYDRANTFIBERGLASS REINFORCED PLASTICFIRE RETARDANT TREAT(ED, MENT) GGA GALV GL GWBGYP HBHC HDR HDWD HMHORHPHRHTHTGHTRHVAC HWHWR IDIN INCANINSULINTINV JBJCJT L LABLAMLAV LINLLLLHLLVLP GASGAGE GALVANIZED GLASS/GLAZING GYPSUM WALL BOARDGYPSUM HOSE BIBBHOLLOW CORE HEADERHARDWAREHARDWOOD HOLLOW METALHORIZONTALHIGH POINTHANDRAIL/HOURHEIGHTHEATING HEATING, VENTILATING, HOT WATERHOT WATER RETURN INSIDE DIAMETERINCH INCANDESCENTINSULAT(E, D, ION)INTERIORINVERT JUNCTION BOXJANITOR'S CLOSETJOINT LENGTH, LONG (STRUCTURAL SHAPEANGLE IN THE CONTEXT OF LABORATORYLAMINATE(D)LAVATORY LINOLEUMLIVE LOADLONG LEG HORIZONTALLONG LEG VERTICALLOW POINT (LOW PRESSURE INTHE CONTEXT OF HVAC DRAWINGS) HEATER HDW MC MECHMEMB MFRMHMICROW MIN MOMTDMTGMTL NNIC NOMNTS OAOCOD OHOPGOPPOZ PPB PCCPDPHPILPLPLAM PLASPLMBG PSFPSI PTPTNPVC STRUCTURAL SHAPE MISCELLANEOUSCHANNEL IN THE CONTEXT OF MECHANICALMEMBRANE MANUFACTURERMANHOLEMICROWAVE OVEN MINIMUM OR MINUTES MASONRY OPENINGMOUNTEDMOUNTINGMETAL NORTHNOT IN CONTRACT NOMINALNOT TO SCALE OVERALLON CENTEROUTSIDE DIAMETER OVERHEADOPENINGOPPOSITEOUNCE POLEPULLBOX PRECAST CONCRETEPRESSURE DROPPHASEPILASTERPLATEPLASTIC LAMINATE PLASTERPLUMBING POUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCH PRESSURE TREATEDPARTITIONPOLYVINYL CHLORIDE QTQTY SCSCHED SECTSFSG SHTSIMSOGSPSPEC SQ SS STDSTLSTORSTRUCTSUSP TT/T&BT&GTCT/C TELTEMPTERR THDTHKTHR TOILTOSTOW TS T/STVTYP UCUGUHULUNFINUNOUPSUTIL VBVCTVERTVESTVIFVJVTVTRVWC W/DWW/W/OW WCWD WR WSCTWTWWF QUARRY TILEQUANTITY SOLID CORESCHEDULE(D) SECTIONSQUARE FEETSAFETY GLASS SHEETSIMILAR(CONCRETE) SLAB ON GRADESUMP PUMPSPECIFICATIONS SQUARE STAINLESS STEEL, SANITARY SEWER STANDARDSTEELSTORAGESTRUCTURALSUSPENDED TREADTOP OFTOP & BOTTOMTONGUE AND GROOVETERNE COATEDTOP OF CURB TELEPHONETEMPERATURETERRAZZO THREAD(ED)THICK(NESS)THRESHOLD TOILETTOP OF SLABTOP OF WALL STRUCTURAL TUBULAR STEEL IN THECONTEXT OF STRUCTURAL DRAWINGSTOP OF STEELTELEVISIONTYPICAL UNDERCUTUNDERGROUNDUNIT HEATERUNDERWRITERS LABORATORIESUNFINISHEDUNLESS NOTED OTHERWISEUNINTERRUPTABLE POWER SUPPLYUTILITY VAPOR BARRIERVINYL COMPOSITION TILEVERTICALVESTIBULEVERIFY IN FIELDAESTHETIC "V" JOINTVAPOR TIGHTVENT THROUGH ROOFVINYL WALL COVERING WASHER/DRYERWIDE, WIDTH, WATERWITHWITHOUTSTRUCTURAL SHAPE WIDE FLANGE INTHE CONTEXT OF STRUCTURAL DRAWINGSWATER CLOSETWOOD WATER RESISTANT WAINSCOTWEIGHTWELDED WIRE FABRIC STRUCTURAL DRAWINGS) STRUCTURAL DRAWINGS/ CAT CATALOG I.E.THAT IS NO #NUMBER ST STORM SEWER T/F TOP OF FRAME ROUNDRND RECESSED PAPER TOWELROUGH OPENINGRPTDDRO REFRIGERAT(OR, ANT, ATION) REINFORCED CONCRETE PIPERISER, RADIUSR RELOCATED EXISTING RESILIENTREQUIREDREINFORCE(ED, MENT)REFLECTED ROOF DRAIN RMRLE RESILREQDREINF ROOM RD REFLREFG RCP ADDITIONALADD'L. AIR HANDLING UNITAHU APPROXIMATEAPPROXARCHARCHITECT(URE,URAL) BOTTOM OFB/ CL CENTER LINE CONFERENCECONF DA DOUBLE ACTING DIVISIONDIV ELECTRICAL CONTRACTOREC FIXTUREFIX FEMININE NAPKIN VENDERFNDFNVFEMININE NAPKIN DISPOSAL FURNISH, FURNITUREFURRING, FURREDFOOTINGFEET, FOOTFTFTG FURNFUR GAL GALLON GRAB BARGBGENERAL CONTRACTORGC GROUNDGND HIGHH HEAVY DUTYHD HARDWAREHDWR INFO INFORMATION KPL KICKPLATE LEFT HAND REVERSELEFT HAND(ED)LINEAR FOOTLF LHRLH LOUVERLVR MACHINEMACH MASONRYMASMATERIALMAT MEZZANINEMEZZ MILLIMETER(S)MIL MIRRORMIRMOULDINGMLD MECHANICAL CONTRACTOR PLUMBING CONTRACTORPC PANELPNLPAINT(ED)POLYISOCYANURATEPOLYPNT PLYWD PLYWOOD RIGHT HAND REVERSERHRRIGHT HANDRH ROOF TOP UNITRECESSED SOAP DISPENSERRTURSDDISPENSER AND DISPOSAL RIGHT OF WAYROW SOAP DISPENSERSD SEMI-RECESSEDSR SHEET VINYLSV THROUGHTHRU TOILET PAPER HOLDERTPH VINYLV WATERPROOF / WORKING POINTWP WATER RESISTANT TILE BACKER BOARDWRTBB CAFETERIACAFET BUILT-UP ROOFBUR EPAINT EPOXY PAINT TECHNOLOGYTECH SYNTH SYNTHETIC SH STUDY HALL OFF OFFICE MAINT MAINTENANCE FOLDING PARTITION WALLFPW PREFIN PREFINISHED AND AIR CONDITIONING ABBREVIATIONS STONE (CUT OR CAST) FINISH WOOD GYPSUM WALLBOARD OR GROUT STEEL BATT INSULATION EARTH PLYWOOD ROUGH WOOD BLOCKING CONCRETE MASONRY UNITS CONCRETE MATERIAL INDICATIONS GRANULAR FILL RIGID INSULATION (OR NEW WALL ON FLOOR PLANS ONLY) INDICATORS 1i 1i 101 A101 1 Ref 1Re f 1 Ref 1Re f A101 1 Ref 1Re f 1 Re f 1 Ref EXTERIOR ELEVATION INTERIOR ELEVATION SECTION DOORS WALL TYPES STOREFRONT TYPES DRAWING LIST S100 SITE PLAN ARCHITECTURAL T100 COVER SHEET & GENERAL INFORMATION D100 BASEMENT DELOITION PLAN D101 FIRST & SECOND FLOOR DEMOLITION PLAN A100 BASEMENT FLOOR PLAN A101 FIRST FLOOR PLAN A102 SECOND FLOOR PLAN A103 GARAGE PLAN A200 EXTERIOR ELEVATIONS A201 EXTERIOR ELEVATIONS A400 REFLECTED CEILING PLANS A600 ENLARGED PLANS & DETAILS Se a l Pr o j e c t N a m e Dr a w i n g T i t l e Pr o j e c t N o . Pr i n t D a t e CO N T R A C T O R S H A L L V E R I F Y A L L D I M E N S I O N A T S I T E , U N A U T H O R I Z E D A L T ER A T I O N S OR A D D I T I O N S T O T H I S D O C U M E N T I S A V I O L A T I O N O F T H E N E W Y O R K S T AT E ED U C A T I O N L A W . De s i g n e d Dr a w n Ch e c k e d St a t u s Da t e Drawing No. WW W . R E 4 O R M A R C H I T E C T UR E . C O M 32 3 C L I N T O N ST R E E T SC H E N E C T A D Y , N Y 12 3 0 5 P: 5 1 8 . 3 9 9 . 4 1 7 4 F: 5 1 8 . 3 9 9 . 4 1 0 5 2/ 1 8 / 2 0 2 6 9 : 5 0 : 4 6 A M LH K LH K CH E C K E R DR B SU B M I T 2/ 1 8 / 2 6 CO V E R S H E E T & G E N E R A L IN F O R M A T I O N NU M B E R Ri s e - M i l e s t o n e M a n o r Re n o v a t i o n T100 16 2 C I R C U L A R S T R E E T SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 Rise - Milestone Manor Renovation 162 CIRCULAR STREET SARATOGA SPRINGS, NY 12866 NO DE S C R I P T I O N DA T E ARCHITECT:OWNER: MECHANICAL/ELECTRICAL ENGINEER: RE4ORM ARCHITECTURE 323 CLINTON STREET SCHENECTADY, NY 12306 RISE HOUSING & SUPPORT SEVICES 127 UNION STREET SARATOGA SPRINGS, NY 12866 ENGINEERED SOLUTIONS 646 PLANK ROAD SUITE 104 CLIFTON PARK, NY 12065 DRAWING LIST ELECTRICAL E000 LEGEND SCHEDULES GENERAL NOTES MECHANICAL M000 HVAC LEGENDS, SYMBOLS, & NOTES PLUMBING P1 PLUMBING 16 2 C I R C U L A R S T R E E T S I T E P L A N 16 2 C I R C U L A R S T R E E T , C I T Y O F S A R A T O G A S P R I N G S , S A R A T O G A C O U N T Y , N E W Y O R K LA N S I N G E N G I N E E R I N G P R E L I M I N A R Y / N O T F O R C O N S T R U C T I O N 24 5 2 S T A T E R O U T E 9 S U I T E 3 0 1 MA L T A , N Y 1 2 0 2 0 (5 1 8 ) 8 9 9 - 5 2 4 3 CI V I L - T R A N S P O R T A T I O N - E N V I R O N M E N T A L - L A N D S U R V E Y I N G EXISTING CONDITIONS & DEMOLITION PLAN LAYOUT, MATERIALS, & GRADING PLAN SITE STATISTICS 16 2 C I R C U L A R S T R E E T S I T E P L A N 16 2 C I R C U L A R S T R E E T , C I T Y O F S A R A T O G A S P R I N G S , S A R A T O G A C O U N T Y , N E W Y O R K LA N S I N G E N G I N E E R I N G P R E L I M I N A R Y / N O T F O R C O N S T R U C T I O N 24 5 2 S T A T E R O U T E 9 S U I T E 3 0 1 MA L T A , N Y 1 2 0 2 0 (5 1 8 ) 8 9 9 - 5 2 4 3 CI V I L - T R A N S P O R T A T I O N - E N V I R O N M E N T A L - L A N D S U R V E Y I N G ASPHALT PAVEMENT DETAIL1 2 SCREEN FENCING DETAIL CONCRETE SIDEWALK DETAIL1 EX I S T I N G G A R G A R E R E L O C A T E D +/ - 1 9 ' - 0 " V I F 5' P R O P E R T Y S E T B A C K 7' - 4"3' - 4" EX I S T . O . H . D O O R O P E N I N G EX I S T . O . H . D O O R O P E N I N G G01G02 G05 G06 G06 G06 G06 G08 G08 2 1 1 2 2 22 G04 3 1/2" 4' - 0" 2 G09 A1033 A103 4 5 A103 G102 G101 G- E 2 G- E 3 ATTIC ACCESS G101 MULTIPURPOSE ROOM G100 G12 G12 G12 G12 G12 G01 G01 G01 2' - 0 " 7' - 7 1/4" G15 G06 G07 G04 G10 G10 G04 G06 G08 G11 G13 G16 G14 G06 G01 G02 G04 G10 G16 4' - 0 " 8" NEW CONCRETE FOUNDATION WALLS & FOOTINGS 8" 1' - 4" 8" 4" EXISTING GARAGE RELOCATED NEW 4" THICK CONCRETE STEM WALL NEW P.T. WOOD SILL (INSTALL WHILE GARAGE IS STILL ON CRIBBING) INSTALL NEW FIBERGLASS BATT INSULATION IN EXISTING EXTERIOR WALLS & 2ND FLOOR FRAMING. PROVIDE 5/8" GYPSUM WALL BOARD ON ALL INTERIOR FACES OF EXTERIOR WALLS, CEILING, CENTER BEAM & COLUMNS. REMOVE EXISTING SHINGLES AND REPLACE WITH NEW FIBERGLASS ARCHITECTURAL SHINGLES TO MATCH NEW SHINGLES BEING INSTALLED ON THE MAIN HOUSE G102 INTERIOR PARTITION 4 3/4" 1 5/8'' GWB 5/8"3 1/2"5/8" 5/8'' GWB GWB CEILING EXISTING STRUCTURE (2) 2x4 TOP PLATE 2x4 BOTTOM PLATE 2x4' WD STUDS @ 16'' O.C. INTERIOR PARTITION EXISTING WALL NEW GWB 2 5/8'' GWB 5/8'' GWB EXISTING STRUCTURE GWB CEILING 5/8'' GWB EXISTING WALL EXISTING WALL EXISTING WALL EXIST 5/8" 5 A103 1 WOOD SEE DOOR SCHEDULE 2 H.M. SE E D O O R S C H E D U L E SEE DOOR SCHEDULE SE E D O O R S C H E D U L E SE E D O O R S C H E D U L E SE E D O O R S C H E D U L E SEE DOOR SCHEDULE 5 WOOD BI-FOLD PANELED DOOR 4 WOOD DUTCH DOOR SE E D O O R S C H E D U L E SEE DOOR SCHEDULE 3' - 2 " PANELED DOOR 3 WOOD SE E D O O R S C H E D U L E SEE DOOR SCHEDULE PANELED DOOR Se a l Pr o j e c t N a m e Dr a w i n g T i t l e Pr o j e c t N o . Pr i n t D a t e CO N T R A C T O R S H A L L V E R I F Y A L L D I M E N S I O N A T S I T E , U N A U T H O R I Z E D A L T ER A T I O N S O R A D D I T I O N S T O T H I S DO C U M E N T I S A V I O L A T I O N O F T H E N E W Y O R K S T A T E E D U C A T I O N L A W . De s i g n e d Dr a w n Ch e c k e d St a t u s Da t e Drawing No. OF WW W . R E 4 O R M A R C H I T E C T U R E . C O M 32 3 C L I N T O N S T R E E T SC H E N E C T A D Y , N Y 12 3 0 5 P: 5 1 8 . 3 9 9 . 4 1 7 4 F: 5 1 8 . 3 9 9 . 4 1 0 5 2/ 1 8 / 2 0 2 6 9 : 5 0 : 3 7 A M LH K LH K Ch e c k e r DR B SU B M I T 2/ 1 8 / 2 6 GA R A G E P L A N NU M B E R Ri s e - M i l e s t o n e Ma n o r R e n o v a t i o n A103 16 2 C I R C U L A R S T R E E T SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 1/4" = 1'-0"1 GARAGE FLOOR PLAN ROOM FINISH SCHEDULE - GARAGE ROOM NO.ROOM NAME FLOOR BASE WALL CEILING REMARKSMAT'L FINISH MAT'L FINISH MATERIAL FINISH MAT'L FINISH G100 MULTIPURPOSE ROOM CONC LVT NEW VINYL GWB PAINT GWB PAINT G101 ATTIC ACCESS CONC -NEW VINYL GWB PAINT -- DOOR SCHEDULE - GARAGE DOOR NO. ROOM NAME DOOR FRAME LABEL HDW SET CommentsFROMTO SIZE Door Type MAT'L FINISH MAT'L FINISHWHTTHK G101 3' - 0"6' - 8"0' - 1 3/4"1 WOOD PAINT WOOD PAINT -1 G102 ATTIC ACCESS 3' - 0"7' - 0"0' - 1 3/4"2 H.M.PAINT H.M.PAINT -2 G-E2 8' - 0"6' - 8"0' - 1 1/2"EXIST PAINT EXIST PAINT --EXISTING DOOR REMOVE, REINSTALL & PAINT G-E3 8' - 0"6' - 8"0' - 1 1/2"EXIST PAINT EXIST PAINT --EXISTING DOOR REMOVE, REINSTALL & PAINT NOTE: BLANK IN TO OR FROM IS EXTERIOR 3/16" = 1'-0"2 GARAGE EAST ELEVATION1 3/16" = 1'-0"3 GARAGE NORTH ELEVATION1 3/16" = 1'-0"4 GARAGE WEST ELEVATION1 GARAGE NOTES Label Note Comment G01 EXISTING WOOD WINDOW. REMOVE DURING BUILDING RELOCATION & REINSTALL AFTER. REPAIR & REGLAZE AS REQUIRED & PAINT ENTIRE UNIT. G02 NEW PREHUNG WOOD DOOR FULL LIGHT WITH FAUX DIVIDID LIGHTS. PAINT ENTIRE UNIT. G04 NEW 4" THICK CONCRETE FLOOR SLAB & FOUNDATIONS. EXACT SIZE TO MATCH EXISTING GARAGE BEING RELOCATED. REFER TO SECTION FOR MORE INFORMATION. G05 EXISTING STAIR TO STORAGE ATTIC. AFTER BUILDING RELOACTION REPAIR STAIR & LANDINGI AS REQUIRED. G06 EXISTING GARAGE EXTERIOR WALLS. REPAIR ANY DAMAGED OR DETERIORATED EXTERIOR SIDING & TRIM AS REQUIRED WITH MATERIALS TO MATCH EXISTING. PAINT EXTERIOR TO MATCH MAIN HOUSE. G07 EXISTING SWING DOOR. REMOVE PRIOR TO GARAGE BUILDING RELOCATION AND REINSTALL AFTER. REPAIR ALL ROT AND DAMAGE (EXISTING OR CREATED DURING REMOVAL& REINSTALLATION), REGLAZE WINDOWS IF NEEDED AND PAINT. G08 EXISTING OVERHEAD GARAGE DOORS. REMOVE PRIOR TO GARAGE BUILDING RELOCATION AND REINSTALL AFTER. REPAIR ALL ROT AND DAMAGE (EXISTING OR CREATED DURING REMOVAL& REINSTALLATION), AND PAINT. G09 NEW ELECTRIC PANEL LOCATION G10 EXISTING GARAGE ROOF. REMOVE EXISTING SHINGLES AND REPAIR SHEATHING AS REQUIRED. REPLACE SHINGLES WITH NEW FIBERGLASS ARCHITECTURAL SHINGLES TO MATCH NEW SHINGLES BEING INSTALLED ON THE MAIN HOUSE G11 EXISTING GARAGE OVERHEAD DOOR, MODIFY TOP PANEL TRO ADD GLAZING TO EXISTING PANELS. GLAZING TO BE INSULATED SAFETY GLAZING PANELS. G12 EXISTING GARAGE EXTERIOR WALLS, PROVIDE NEW FIBERGLASS BATT INSULATION & 5/8" GYPSUM WALL BOARD ON THE INTERIOR. REPLACE SILL WITH P.T. 2x PLATE WHILE THE GARAGE IS RAISED ON MOVERS TIBERS & CRIBBING. G13 NEW WOOD ATTIC ACCESS DOOR WITH TRIM DETAILS TO LOOK LIKE BARN DOOR. LOCATED DOOR IN EXISTING WINDOW OPENING. G14 NEW WALL HUNG MINI-SPLIT CONDESERS G15 (2) NEW WOOD 2x4 AND PLYWOOD SHELVES FOR BIN STORAGE. G16 REMOVE & REPLACE EXISTING EXTERIOR LIGHT FIXTURE WITH NEW. SEE ELECTRICAL DRAWINGS. 3/8" = 1'-0"5 GARAGE SECTION 3/4" = 1'-0" WALL TYPES PROJECT NO DE S C R I P T I O N DA T E 1/4" = 1'-0"6 GARAGE REFLECTED CEILING PLAN 1/4" = 1'-0" DOOR LEGEND First Floor 0' - 0" Second Floor 10' - 0" Basement-7' - 10" Third Floor20' - 0" E01 E01 E02 E01 E01 E02 E02 E02 E02 E01 E03 E03 E01 E02 E04 E04 E04 E04 E04 E12 First Floor0' - 0" Second Floor10' - 0" Basement-7' - 10" Third Floor20' - 0" E08 E07 E01 E02 E04 E04 E01 E02 E05 E03 E01 E02 E01 E13 E14 E15 Se a l Pr o j e c t N a m e Dr a w i n g T i t l e Pr o j e c t N o . Pr i n t D a t e CO N T R A C T O R S H A L L V E R I F Y A L L D I M E N S I O N A T S I T E , U N A U T H O R I Z E D A L T ER A T I O N S O R A D D I T I O N S T O T H I S DO C U M E N T I S A V I O L A T I O N O F T H E N E W Y O R K S T A T E E D U C A T I O N L A W . De s i g n e d Dr a w n Ch e c k e d St a t u s Da t e Drawing No. OF WW W . R E 4 O R M A R C H I T E C T U R E . C O M 32 3 C L I N T O N S T R E E T SC H E N E C T A D Y , N Y 12 3 0 5 P: 5 1 8 . 3 9 9 . 4 1 7 4 F: 5 1 8 . 3 9 9 . 4 1 0 5 2/ 1 8 / 2 0 2 6 9 : 5 0 : 4 1 A M LH K LH K Ch e c k e r DR B SU B M I T 2/ 1 8 / 2 6 EX T E R I O R E L E V A T I O N S NU M B E R Ri s e - M i l e s t o n e Ma n o r R e n o v a t i o n A200 16 2 C I R C U L A R S T R E E T SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 ELEVATION NOTES LABEL NOTE E01 EXISTING PAINT HAS TESTED POSSITIVE FOR LEAD. PREPAIR EXISTING PAINTED SURFACES UTILIZING LEAD SAFE WORK PRACTICES. REPAINT ALL EXISTING PAINTED SURFACES WITH EPA APPROVED ENCAPSULATING PAINT. E02 REPAIR OR REPLACE ALL DETERIORATED SIDING, TRIM, WINDOW TRIM AND EXISTING BUILDING ELEMENTS AS REQUIRED. ARCHITECT & CONTRACTOR TO INSPECT BUILDING TOGETHER TO DETERTMINE AREAS REQUIRED TO BE ADDRESSED. ALL ITEMS TO BE REPLACED SHALL BE REPLACED WITH MATERIALS "IN KIND" WITH EXISTING. E03 EXISTING RAILINGS, LATTICE & DECK SCREENS ARE TO REMAIN. REMOVE AS REQUIRED DURING DECKING & SUPPORT WORK & REINSTALL. REPAIR OR REPLACE ALL DETERIORATED ELEMENTS WITH NEW MATERIALS WHICH ARE "IN KIND" WITH THE EXISTING TO REMAIN. REPAINT FOLLOWING EPA REGULATIONS & GUIDELINES E04 REMOVE & REPLACE EXISTING ASPHALT SHINGLE ROOFING COMPLETE. INSPECT EXISTING ROOF SHEATHING & REPLACE AS REQUIRED. NEW SHINGLES ARE TO BE ARCHECTURAL ASPHALT SHINGLE COLOR TO MATCH EXISTING. E05 EXISTING PORCH DECK BOARDS, SUPPORTS, COLUMNS, STAIRS (REAR), AND ALL ASSOCIATED ITEMS ARE TO BE INSPECTED AND REPAIRED OR REPLACED AS REQUIRED WITH NEW MATERTIALS WHICH ARE TO BE "IN KIND" WITH THE EXISTING TO REMAIN. ALL ITEMS ARE TO BE REPAINTED PER EPA REGULATIONS & GUIDELINES. E06 EXISTING FRONT DOORS TO REMAIN. REVISE EXISTING DOOR HARDWARE AS REQUIRED TO ENSURE SAFE EGRESS. E07 (3) NEW HVAC CONDENSING UNITS MOUNTED ON PREMANUFACTURED STEEL TUBE STANDS ON A NEW 4" CONCRETE SLAB. SEE MECHANICAL DRAWINGS. E08 REMOVE EXISTING WINDOW COMPLETE. INFILL EXISTING WINDOW OPENING WITH GLASS BLOCK & VENTILATION FAN. E09 EXISTING WOOD STAIR REMOVE & CONSTRUCT NEW TO MATCH EXISTING. PAINT TO MATCH EXISTING. INSTALL NON SLIP POWDER COATED ALUMINUM HANDI-TREADS ON EACH TREAD & AT TOP LANDING. COLOR NEW ENGLAND GRAY. E10 EXISTING CONCRETE STAIR REPAIR AS REQUIRED. INSTALL NON SLIP POWDER COATED ALUMINUM HANDI-TREADS ON EACH TREAD & AT TOP LANDING. COLOR NEW ENGLAND GRAY. E11 INFILL EXISTING WINDOW OPENING WITH GLASS BLOCK & VENTILATION FAN. E12 INVESTIGATE & REPAIR ANY DAMAGE TO THE PORCH & ROOF SUPPORTS IN THIS AREA. EXISTING CONDITIONS INDICATE POSSIBLE STRUCTURAL DAMAGE IN THIS AREA. NOTIFY ARCHITECT OF FINDINGS. E13 EXISTING FENCE TO BE REPLACED WITH NEW FENCE. NEW FENCE TO MATCH EXISTING IN MATERIAL, SIZE, & STYLE. E14 EXISTING GAZEBO TO BE REPLACED WITH NEW. NEW GAZEBO TO MATCH EXISTING IN MATERIAL, SIZE, & STYLE. E15 REMOVE & REPLACE EXISTING EXTERIOR LIGHT FIXTURE WITH NEW. SEE ELECTRICAL DRAWINGS. 3/16" = 1'-0"1 NORTH ELEVATION 3/16" = 1'-0"2 EAST ELEVATION NO DE S C R I P T I O N DA T E GENERAL NOTE: REFER TO THE LEAD BASED PAINT SURVEY INCLUDED IN THE SPSECIFICATION. EXTERIOR SURFACES CONTAINING LEAD PAINT ARE INCLUDED IN THIS DOCUMENT. CONTRACTOR IS TO USE LEAD SAFE WORK PRACTICES IN COMPLIANCE WITH THE EPA RENOVATION, REPAIR, AND PAINTING RULE, OR CONFIRM THE ABSENCE OF LEAD-BASED PAINT USING AN EPA RECOGNIZED TEST KIT. EPA APPROVED DOCUMENTATION FORM TO BE SUBMITTED TO THE OWNER AND PROGRAM PRIOR TO STARTING PAINT STABILIZATION WORK. NEW EXTERIOR LIGHT FIXTURE First Floor0' - 0" Second Floor10' - 0" Basement-7' - 10" Third Floor 20' - 0" E04 E04 E04 E01 E02 E03 E05 E03 E05 E01 E02 E06 First Floor0' - 0" Second Floor10' - 0" Basement-7' - 10" Third Floor 20' - 0" E01 E02 E02 E01 E04 E04 E05 E03 E01 E02 E04 E01 E01 E02 E04 E07 Se a l Pr o j e c t N a m e Dr a w i n g T i t l e Pr o j e c t N o . Pr i n t D a t e CO N T R A C T O R S H A L L V E R I F Y A L L D I M E N S I O N A T S I T E , U N A U T H O R I Z E D A L T ER A T I O N S O R A D D I T I O N S T O T H I S DO C U M E N T I S A V I O L A T I O N O F T H E N E W Y O R K S T A T E E D U C A T I O N L A W . De s i g n e d Dr a w n Ch e c k e d St a t u s Da t e Drawing No. OF WW W . R E 4 O R M A R C H I T E C T U R E . C O M 32 3 C L I N T O N S T R E E T SC H E N E C T A D Y , N Y 12 3 0 5 P: 5 1 8 . 3 9 9 . 4 1 7 4 F: 5 1 8 . 3 9 9 . 4 1 0 5 2/ 1 8 / 2 0 2 6 9 : 5 0 : 4 4 A M LH K LH K Ch e c k e r DR B SU B M I T 2/ 1 8 / 2 6 EX T E R I O R E L E V A T I O N S NU M B E R Ri s e - M i l e s t o n e Ma n o r R e n o v a t i o n A201 16 2 C I R C U L A R S T R E E T SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 3/16" = 1'-0"1 WEST ELEVATION 3/16" = 1'-0"2 SOUTH ELEVATION ELEVATION NOTES LABEL NOTE E01 EXISTING PAINT HAS TESTED POSSITIVE FOR LEAD. PREPAIR EXISTING PAINTED SURFACES UTILIZING LEAD SAFE WORK PRACTICES. REPAINT ALL EXISTING PAINTED SURFACES WITH EPA APPROVED ENCAPSULATING PAINT. E02 REPAIR OR REPLACE ALL DETERIORATED SIDING, TRIM, WINDOW TRIM AND EXISTING BUILDING ELEMENTS AS REQUIRED. ARCHITECT & CONTRACTOR TO INSPECT BUILDING TOGETHER TO DETERTMINE AREAS REQUIRED TO BE ADDRESSED. ALL ITEMS TO BE REPLACED SHALL BE REPLACED WITH MATERIALS "IN KIND" WITH EXISTING. E03 EXISTING RAILINGS, LATTICE & DECK SCREENS ARE TO REMAIN. REMOVE AS REQUIRED DURING DECKING & SUPPORT WORK & REINSTALL. REPAIR OR REPLACE ALL DETERIORATED ELEMENTS WITH NEW MATERIALS WHICH ARE "IN KIND" WITH THE EXISTING TO REMAIN. REPAINT FOLLOWING EPA REGULATIONS & GUIDELINES E04 REMOVE & REPLACE EXISTING ASPHALT SHINGLE ROOFING COMPLETE. INSPECT EXISTING ROOF SHEATHING & REPLACE AS REQUIRED. NEW SHINGLES ARE TO BE ARCHECTURAL ASPHALT SHINGLE COLOR TO MATCH EXISTING. E05 EXISTING PORCH DECK BOARDS, SUPPORTS, COLUMNS, STAIRS (REAR), AND ALL ASSOCIATED ITEMS ARE TO BE INSPECTED AND REPAIRED OR REPLACED AS REQUIRED WITH NEW MATERTIALS WHICH ARE TO BE "IN KIND" WITH THE EXISTING TO REMAIN. ALL ITEMS ARE TO BE REPAINTED PER EPA REGULATIONS & GUIDELINES. E06 EXISTING FRONT DOORS TO REMAIN. REVISE EXISTING DOOR HARDWARE AS REQUIRED TO ENSURE SAFE EGRESS. E07 (3) NEW HVAC CONDENSING UNITS MOUNTED ON PREMANUFACTURED STEEL TUBE STANDS ON A NEW 4" CONCRETE SLAB. SEE MECHANICAL DRAWINGS. E08 REMOVE EXISTING WINDOW COMPLETE. INFILL EXISTING WINDOW OPENING WITH GLASS BLOCK & VENTILATION FAN. E09 EXISTING WOOD STAIR REMOVE & CONSTRUCT NEW TO MATCH EXISTING. PAINT TO MATCH EXISTING. INSTALL NON SLIP POWDER COATED ALUMINUM HANDI-TREADS ON EACH TREAD & AT TOP LANDING. COLOR NEW ENGLAND GRAY. E10 EXISTING CONCRETE STAIR REPAIR AS REQUIRED. INSTALL NON SLIP POWDER COATED ALUMINUM HANDI-TREADS ON EACH TREAD & AT TOP LANDING. COLOR NEW ENGLAND GRAY. E11 INFILL EXISTING WINDOW OPENING WITH GLASS BLOCK & VENTILATION FAN. E12 INVESTIGATE & REPAIR ANY DAMAGE TO THE PORCH & ROOF SUPPORTS IN THIS AREA. EXISTING CONDITIONS INDICATE POSSIBLE STRUCTURAL DAMAGE IN THIS AREA. NOTIFY ARCHITECT OF FINDINGS. E13 EXISTING FENCE TO BE REPLACED WITH NEW FENCE. NEW FENCE TO MATCH EXISTING IN MATERIAL, SIZE, & STYLE. E14 EXISTING GAZEBO TO BE REPLACED WITH NEW. NEW GAZEBO TO MATCH EXISTING IN MATERIAL, SIZE, & STYLE. E15 REMOVE & REPLACE EXISTING EXTERIOR LIGHT FIXTURE WITH NEW. SEE ELECTRICAL DRAWINGS. NO DE S C R I P T I O N DA T E GENERAL NOTE: REFER TO THE LEAD BASED PAINT SURVEY INCLUDED IN THE SPSECIFICATION. EXTERIOR SURFACES CONTAINING LEAD PAINT ARE INCLUDED IN THIS DOCUMENT. CONTRACTOR IS TO USE LEAD SAFE WORK PRACTICES IN COMPLIANCE WITH THE EPA RENOVATION, REPAIR, AND PAINTING RULE, OR CONFIRM THE ABSENCE OF LEAD-BASED PAINT USING AN EPA RECOGNIZED TEST KIT. EPA APPROVED DOCUMENTATION FORM TO BE SUBMITTED TO THE OWNER AND PROGRAM PRIOR TO STARTING PAINT STABILIZATION WORK.