HomeMy WebLinkAbout20190786 Fleming Residence Revised Narrative \
I \\\ I
ARCH1TEC Tc)
11/15/19 FLEMING RESIDENCE 75 Ludlow Street
Lot Size = 50 x 150' = 7500 SF, width= 50'
Minimum lot size in UR-3 zone = 6600 SF, width 60'
Principal Building
Existing house footprint (incl. roof 0.11) = 1524.0 SF
Proposed Additions - Kitchen Addition 63.0
N. Screened Porch 231.0
South Porch 170.0
Steps J Screened Porch 24.0
488.0 SF
Proposed house footprint - 1524.0 +488.0 = 2012.0 SF
Principal Building proposed lot coverage = 2012 / 7500 = 26.8%
Allowed max. lot coverage of Principal Building in UR-3 zone — 30%
Accessory Structures
Proposed Garage (incl. roof O.H.) = 738.0 SF
Accessory Structure proposed lot coverage = 738.0 / 7500 = 9.8%
Allowed max. lot coverage of Accessory Structure in UR-3 zone = 10%
Permeable Area of Lot
Proposed impermeable area of lot = 3281 SF
Proposed permeable area of lot= 7500-3281 =4219 SF
rrk H11,-;N.Frost..11%, nil I 1 ico:I I.I , mit rifhtirclLcum
.11014zi Springs. Ncw Vurk 1126 !Th-; 1 71 581-75'2:; www,i
Permeable proposed area of lot = 4219 / 7500 56.25%
Set-Backs Min. Req'd Proposed
Principal Building Front Yard - 10' 63 (pre-exist.), 9.25'
Each Side - 4' 3.9' (pre-exist.), 72.0'
Total Side - 12' 75.9'
Accessory Structure Front Yard - 10' 19.5', 112'
Side Yard - 5' 5.0'