HomeMy WebLinkAbout20190786 Fleming Residence Revised Narrative \ I \\\ I ARCH1TEC Tc) 11/15/19 FLEMING RESIDENCE 75 Ludlow Street Lot Size = 50 x 150' = 7500 SF, width= 50' Minimum lot size in UR-3 zone = 6600 SF, width 60' Principal Building Existing house footprint (incl. roof 0.11) = 1524.0 SF Proposed Additions - Kitchen Addition 63.0 N. Screened Porch 231.0 South Porch 170.0 Steps J Screened Porch 24.0 488.0 SF Proposed house footprint - 1524.0 +488.0 = 2012.0 SF Principal Building proposed lot coverage = 2012 / 7500 = 26.8% Allowed max. lot coverage of Principal Building in UR-3 zone — 30% Accessory Structures Proposed Garage (incl. roof O.H.) = 738.0 SF Accessory Structure proposed lot coverage = 738.0 / 7500 = 9.8% Allowed max. lot coverage of Accessory Structure in UR-3 zone = 10% Permeable Area of Lot Proposed impermeable area of lot = 3281 SF Proposed permeable area of lot= 7500-3281 =4219 SF rrk H11,-;N.Frost..11%, nil I 1 ico:I I.I , mit rifhtirclLcum .11014zi Springs. Ncw Vurk 1126 !Th-; 1 71 581-75'2:; www,i Permeable proposed area of lot = 4219 / 7500 56.25% Set-Backs Min. Req'd Proposed Principal Building Front Yard - 10' 63 (pre-exist.), 9.25' Each Side - 4' 3.9' (pre-exist.), 72.0' Total Side - 12' 75.9' Accessory Structure Front Yard - 10' 19.5', 112' Side Yard - 5' 5.0'