HomeMy WebLinkAbout20260093 129 Circular St Special Use Permit PlansEXISTING
(NO WORK)
CARRIAGE HOUSE
(INTERIOR
ALTERATIONS)
10' - 1"GROUND MOUNTED
A/C CONDENSER
NEW CONNECTION
TO (E) DOMESTIC
WATER SERVICE IN
MAIN RESIDENCE,
T.B.C.
NEW CONNECTION
TO (E) SANITARY
LINE, T.B.C.
ASSUMED (E)
SANITARY LINE
Seal:
SCHEMATIC
DESIGN
CONSTRUCTION
DOCUMENTS
PROGRESS:
Project Number
Date
Drawn by
Checked by
USE OF ARCHITECTS DOCUMENTS:
THESE DOCUMENTS PREPARED BY THE
ARCHITECT ARE INSTRUMENTS OF SERVICE
FOR USE SOLELY WITH RESPECT TO THIS
PROJECT, AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. THE
ARCHITECT SHALL RETAIN ALL COMMON
LAW, STATUTORY AND OTHER RESERVED
RIGHTS INCLUDING THE COPYRIGHT(S). THE
OWNER SHALL NOT REUSE OR PERMIT THE
REUSE OF THESE DOCUMENTS INCLUDING
ANY DESIGN & CONSTRUCTION
DEVELOPMENT, CHANGES OR ALTERATIONS
TO THESE DOCUMENTS, WITHOUT THE
WRITTEN ACKNOWLEDGEMENT AND
AUTHORIZATION OF THE ARCHITECT
Consultant Logo
OWNER :
12/10/2025 4:07:17 PM
G002
SURVEY & DRB
NOD
2420
RUBACKY
RESIDENCE -
CARRIAGE HOUSE
07.18.25
DC
MT
PETER & LESLIE RUBACKY
129 CIRCULAR ST.
SARATOGA SPRINGS, NY 12866
TBD
GENERAL CONTRACTOR:
129 CIRCULAR ST,
SARATOGA SPRINGS, NY 12866
1
1
1
1
No.Description Date
1 REVISED PER
PERMIT REVIEW
11.11.2025
GENERAL CONSTRUCTION: GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS IN FIELD AND REPORT ALL DISCREPANCIES TO THE ARCHITECT
FOR RESOLUTION PRIOR TO COMMENCEMENT OF WORK.
3. DIMENSIONS ARE TO F/ EXISTING CONSTRUCTION, F/ CONCRETE, CENTERLINE OF
STRUCTURE, F/ STUD, CENTER OF OPENING, OR CENTER OF FIXTURE, UNLESS NOTED
OTHERWISE.
4. ALL OVERALL DIMENSIONS ARE +/-THE GIVEN DIMENSION. REFER TO STRUCTURAL
DRAWINGS FOR FOUNDATION DIMENSIONS AND WALL SECTIONS FOR UPPER WALL
ALIGNMENT.
5. WHERE A COLUMN IS SHOWN WITHIN A FRAMED WALL, LOCATE WALL TO CENTER THE
FRAMING ON THE COLUMN LINE, UNLESS DIMENSIONED OTHERWISE.
6. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO, BUT NOT LIMITED TO,
PLUMBING, PIPING, ELECTRICAL COMPONENTS, AND DUCTING TO MAKE THE WORK
COMPLETE AND OPERATIONAL.
7. MINOR ITEMS OF WORK SUCH AS CUTTING, BLOCKING, TRIM, ETC. SHALL BE
PERFORMED AS REQUIRED TO MAKE THE WORK COMPLETE WHETHER SHOWN OR
NOTED ON THE DRAWINGS OR NOT.
8. PROVIDE BLOCKING TO SUPPORT FIXTURES, EQUIPMENT, SHELVING, MILLWORK, AND
SIMILAR WALL MOUNTED CONSTRUCTION AS REQUIRED FOR STABLE INSTALLATION.
FIELD VERIFY ALL SUCH LOCATIONS.
9. WHERE NO SPECIFIC PRODUCT IS SPECIFIED, CONTRACTOR SHALL PROVIDE
PRODUCTS THAT MEET THE INDUSTRY STANDARD AND ARE COMPATIBLE WITH ALL
ADJACENT AND ASSOCIATED CONSTRUCTION. WHERE THERE IS AESTHETIC IMPACT,
THE CONTRACTOR SHALL SUBMIT THE PROPOSED PRODUCT FOR ARCHITECT'S
APPROVAL.
A201
3
A201
4
A201
1
A201
2 1
A301
1
A301
2
A301
2
A301
A501
1
CL.
POWDER
ROOM
STORAGE
+/
-
2
0
'
-
1
1
1
/
4
"
3
1
/
2
"
6'
-
7
1
/
4
"
+/
-
2
7
'
-
1
0
"
8' - 5 1/2"
3 1/2"
9' - 6"
3 1/2"
+/- 6' - 2"
6'
-
0
"
1
2
'
-
8
"
3
1
/
2
"
2'
-
5
1
/
2
"
+
/
-
6
'
-
5
"
+/- 24' - 8 1/2"
WETBAR
DINING AREA
LIVING AREA
EXISTING EXTERIOR BARN
DOORS TO REMAIN ON
REVERSED HINGES
101
103
102
+/
-
2
7
'
-
1
0
"
+/- 24' - 8 1/2"
2' - 10" 6' - 4 3/4" 6' - 3 3/4" 6' - 4 1/2" 2' - 6" 3 1/2"
A
7' - 9 1/4" 16' - 7 3/4"
13
'
-
1
0
1
/
2
"
6
'
-
1
1
3
/
4
"
MINI SPLIT HVAC UNIT ABOVE
ON-DEMAND HOT WATER HEATER
EXTG
EXTG
EXTG
GC TO DISCUSS OPTION FOR
RADIANT FLOOR WARMING AT
POWDER ROOM WITH OWNER
AA A
DOOR BOLLARD W/ LATCH
TO SECURE OPEN DOOR
DOOR LATCH TO SECURE
OPEN DOOR
BA
R
+/- 4' - 7 1/2"
+/
-
3
'
-
4
"
T
REUSE EXISTING DOOR, GC TO
COORDINATE W/ OWNERS
UP
PROVIDE ROUGH-INS FOR 32"x32" SHOWER
PENDING SPECIAL USE APPROVAL FOR
CONVERSION TO DWELLING
A201
3
A201
4
A201
1
A201
2 1
A301
1
A301
2
A301
2
A301
A501
2
16
'
-
5
1
/
2
"
1
1
'
-
4
1
/
2
"
OPEN TO
BELOW
8' - 9 1/2" 9' - 5" 6' - 6"
11
'
-
4
1
/
2
"
24' - 8 1/2"
24' - 8 1/2"
27
'
-
1
0
"
27
'
-
1
0
"
MINI SPLIT HVAC UNIT ABOVE
EXTG
EXTG
EXTG
EXISTING EXTERIOR DOOR
TO REMAIN ON REVERSED
HINGESB
1'
-
2
1
/
2
"
+/
-
8
'
-
9
3
/
4
"
OPEN TO
BELOW
1'
-
2
1
/
2
"
1'
-
2
1
/
2
"
DASHED LINE INDICATES
SHELF BELOW
STORAGE LOFT
A201
3
A201
4
A201
1
A201
2 1
A301
1
A301
2
A301
2
A301
EXISTING METAL RIDGE CAP TO REMAIN
6
1
/
2
"
/
1
2
"
6
1
/
2
"
/
1
2
"
EXISTING SLATE ROOFING TO REMAIN. CLEAN
SURFACE TO REMOVE ALGAE. REPLACE
DAMAGED OR MISSING SLATE AFTER
STRUCTURAL ALTERATIONS ARE COMPLETE
+/
-
+
/
-
Seal:
SCHEMATIC
DESIGN
CONSTRUCTION
DOCUMENTS
PROGRESS:
Project Number
Date
Drawn by
Checked by
USE OF ARCHITECTS DOCUMENTS:
THESE DOCUMENTS PREPARED BY THE
ARCHITECT ARE INSTRUMENTS OF SERVICE
FOR USE SOLELY WITH RESPECT TO THIS
PROJECT, AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. THE
ARCHITECT SHALL RETAIN ALL COMMON
LAW, STATUTORY AND OTHER RESERVED
RIGHTS INCLUDING THE COPYRIGHT(S). THE
OWNER SHALL NOT REUSE OR PERMIT THE
REUSE OF THESE DOCUMENTS INCLUDING
ANY DESIGN & CONSTRUCTION
DEVELOPMENT, CHANGES OR ALTERATIONS
TO THESE DOCUMENTS, WITHOUT THE
WRITTEN ACKNOWLEDGEMENT AND
AUTHORIZATION OF THE ARCHITECT
Consultant Logo
OWNER :
12/10/2025 4:07:27 PM
A101
FLOOR AND
ROOF PLANS
2420
RUBACKY
RESIDENCE -
CARRIAGE HOUSE
07.18.25
DC
MT
PETER & LESLIE RUBACKY
129 CIRCULAR ST.
SARATOGA SPRINGS, NY 12866
TBD
GENERAL CONTRACTOR:
129 CIRCULAR ST,
SARATOGA SPRINGS, NY 12866
1/4" = 1'-0"
FIRST FLOOR PLAN11/4" = 1'-0"
LOFT PLAN2
1/4" = 1'-0"
ROOF PLAN3
1
1
1
No.Description Date
1 REVISED PER
PERMIT REVIEW
11.11.2025
2 REVISED PER
SLAB CHANGES
12.10.2025
2
2
2
2
POWDER
ROOM
A702
6
5
4
3
102
103
2'
-
1
0
"
3
1
/
2
"
3'
-
5
3
/
4
"
1' - 4"
3 1/2"
6' - 10"
8' - 5 1/2"
6'
-
7
1
/
4
"
1'
-
6
1
/
2
"
30
'
'
V
A
N
I
T
Y
TANKLESS
WATER HEATER
1'
-
6
1
/
2
"
FUTURE 32"x32"
SHOWER
MIRROR
30'' VANITY
T&G. STND.
1x6 BASE
TRIM, PTD.
T&G, STND.
1x6 BASE
TRIM, PTD.
TOILET
T&G, STND.
1x6 BASE
TRIM, PTD.
DOOR TO WATER
HEATER
1x4 DOOR
CASING, STND.
103
T&G, STND.
1x6 BASE
TRIM, PTD.
1x4 DOOR
CASING, STND.
DOOR TO
DINING AREA
102
Seal:
SCHEMATIC
DESIGN
CONSTRUCTION
DOCUMENTS
PROGRESS:
Project Number
Date
Drawn by
Checked by
USE OF ARCHITECTS DOCUMENTS:
THESE DOCUMENTS PREPARED BY THE
ARCHITECT ARE INSTRUMENTS OF SERVICE
FOR USE SOLELY WITH RESPECT TO THIS
PROJECT, AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT. THE
ARCHITECT SHALL RETAIN ALL COMMON
LAW, STATUTORY AND OTHER RESERVED
RIGHTS INCLUDING THE COPYRIGHT(S). THE
OWNER SHALL NOT REUSE OR PERMIT THE
REUSE OF THESE DOCUMENTS INCLUDING
ANY DESIGN & CONSTRUCTION
DEVELOPMENT, CHANGES OR ALTERATIONS
TO THESE DOCUMENTS, WITHOUT THE
WRITTEN ACKNOWLEDGEMENT AND
AUTHORIZATION OF THE ARCHITECT
Consultant Logo
OWNER :
12/10/2025 4:08:02 PM
A702
INTERIOR
ELEVATIONS
2420
RUBACKY
RESIDENCE -
CARRIAGE HOUSE
07.18.25
DC
MT
PETER & LESLIE RUBACKY
129 CIRCULAR ST.
SARATOGA SPRINGS, NY 12866
TBD
GENERAL CONTRACTOR:
129 CIRCULAR ST,
SARATOGA SPRINGS, NY 12866
MAIN SPACE AXONOMETRIC looking SOUTHWEST1
3/8" = 1'-0"
ENLARGED POWDER ROOM PLAN23/8" = 1'-0"
POWDER ROOM looking EAST33/8" = 1'-0"
POWDER ROOM looking SOUTH4
3/8" = 1'-0"
POWDER ROOM looking WEST53/8" = 1'-0"
POWDER ROOM looking NORTH6POWDER ROOM AXONOMETRIC looking SW7
INTENTIONALLY BLANK INTENTIONALLY BLANK
1
No.Description Date
1 REVISED PER
PERMIT REVIEW
11.11.2025
2 REVISED PER
SLAB CHANGES
12.10.2025
2
2