Loading...
HomeMy WebLinkAbout20260093 129 Circular St Special Use Permit PlansEXISTING (NO WORK) CARRIAGE HOUSE (INTERIOR ALTERATIONS) 10' - 1"GROUND MOUNTED A/C CONDENSER NEW CONNECTION TO (E) DOMESTIC WATER SERVICE IN MAIN RESIDENCE, T.B.C. NEW CONNECTION TO (E) SANITARY LINE, T.B.C. ASSUMED (E) SANITARY LINE Seal: SCHEMATIC DESIGN CONSTRUCTION DOCUMENTS PROGRESS: Project Number Date Drawn by Checked by USE OF ARCHITECTS DOCUMENTS: THESE DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT, AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING THE COPYRIGHT(S). THE OWNER SHALL NOT REUSE OR PERMIT THE REUSE OF THESE DOCUMENTS INCLUDING ANY DESIGN & CONSTRUCTION DEVELOPMENT, CHANGES OR ALTERATIONS TO THESE DOCUMENTS, WITHOUT THE WRITTEN ACKNOWLEDGEMENT AND AUTHORIZATION OF THE ARCHITECT Consultant Logo OWNER : 12/10/2025 4:07:17 PM G002 SURVEY & DRB NOD 2420 RUBACKY RESIDENCE - CARRIAGE HOUSE 07.18.25 DC MT PETER & LESLIE RUBACKY 129 CIRCULAR ST. SARATOGA SPRINGS, NY 12866 TBD GENERAL CONTRACTOR: 129 CIRCULAR ST, SARATOGA SPRINGS, NY 12866 1 1 1 1 No.Description Date 1 REVISED PER PERMIT REVIEW 11.11.2025 GENERAL CONSTRUCTION: GENERAL NOTES 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS IN FIELD AND REPORT ALL DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF WORK. 3. DIMENSIONS ARE TO F/ EXISTING CONSTRUCTION, F/ CONCRETE, CENTERLINE OF STRUCTURE, F/ STUD, CENTER OF OPENING, OR CENTER OF FIXTURE, UNLESS NOTED OTHERWISE. 4. ALL OVERALL DIMENSIONS ARE +/-THE GIVEN DIMENSION. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION DIMENSIONS AND WALL SECTIONS FOR UPPER WALL ALIGNMENT. 5. WHERE A COLUMN IS SHOWN WITHIN A FRAMED WALL, LOCATE WALL TO CENTER THE FRAMING ON THE COLUMN LINE, UNLESS DIMENSIONED OTHERWISE. 6. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO, BUT NOT LIMITED TO, PLUMBING, PIPING, ELECTRICAL COMPONENTS, AND DUCTING TO MAKE THE WORK COMPLETE AND OPERATIONAL. 7. MINOR ITEMS OF WORK SUCH AS CUTTING, BLOCKING, TRIM, ETC. SHALL BE PERFORMED AS REQUIRED TO MAKE THE WORK COMPLETE WHETHER SHOWN OR NOTED ON THE DRAWINGS OR NOT. 8. PROVIDE BLOCKING TO SUPPORT FIXTURES, EQUIPMENT, SHELVING, MILLWORK, AND SIMILAR WALL MOUNTED CONSTRUCTION AS REQUIRED FOR STABLE INSTALLATION. FIELD VERIFY ALL SUCH LOCATIONS. 9. WHERE NO SPECIFIC PRODUCT IS SPECIFIED, CONTRACTOR SHALL PROVIDE PRODUCTS THAT MEET THE INDUSTRY STANDARD AND ARE COMPATIBLE WITH ALL ADJACENT AND ASSOCIATED CONSTRUCTION. WHERE THERE IS AESTHETIC IMPACT, THE CONTRACTOR SHALL SUBMIT THE PROPOSED PRODUCT FOR ARCHITECT'S APPROVAL. A201 3 A201 4 A201 1 A201 2 1 A301 1 A301 2 A301 2 A301 A501 1 CL. POWDER ROOM STORAGE +/ - 2 0 ' - 1 1 1 / 4 " 3 1 / 2 " 6' - 7 1 / 4 " +/ - 2 7 ' - 1 0 " 8' - 5 1/2" 3 1/2" 9' - 6" 3 1/2" +/- 6' - 2" 6' - 0 " 1 2 ' - 8 " 3 1 / 2 " 2' - 5 1 / 2 " + / - 6 ' - 5 " +/- 24' - 8 1/2" WETBAR DINING AREA LIVING AREA EXISTING EXTERIOR BARN DOORS TO REMAIN ON REVERSED HINGES 101 103 102 +/ - 2 7 ' - 1 0 " +/- 24' - 8 1/2" 2' - 10" 6' - 4 3/4" 6' - 3 3/4" 6' - 4 1/2" 2' - 6" 3 1/2" A 7' - 9 1/4" 16' - 7 3/4" 13 ' - 1 0 1 / 2 " 6 ' - 1 1 3 / 4 " MINI SPLIT HVAC UNIT ABOVE ON-DEMAND HOT WATER HEATER EXTG EXTG EXTG GC TO DISCUSS OPTION FOR RADIANT FLOOR WARMING AT POWDER ROOM WITH OWNER AA A DOOR BOLLARD W/ LATCH TO SECURE OPEN DOOR DOOR LATCH TO SECURE OPEN DOOR BA R +/- 4' - 7 1/2" +/ - 3 ' - 4 " T REUSE EXISTING DOOR, GC TO COORDINATE W/ OWNERS UP PROVIDE ROUGH-INS FOR 32"x32" SHOWER PENDING SPECIAL USE APPROVAL FOR CONVERSION TO DWELLING A201 3 A201 4 A201 1 A201 2 1 A301 1 A301 2 A301 2 A301 A501 2 16 ' - 5 1 / 2 " 1 1 ' - 4 1 / 2 " OPEN TO BELOW 8' - 9 1/2" 9' - 5" 6' - 6" 11 ' - 4 1 / 2 " 24' - 8 1/2" 24' - 8 1/2" 27 ' - 1 0 " 27 ' - 1 0 " MINI SPLIT HVAC UNIT ABOVE EXTG EXTG EXTG EXISTING EXTERIOR DOOR TO REMAIN ON REVERSED HINGESB 1' - 2 1 / 2 " +/ - 8 ' - 9 3 / 4 " OPEN TO BELOW 1' - 2 1 / 2 " 1' - 2 1 / 2 " DASHED LINE INDICATES SHELF BELOW STORAGE LOFT A201 3 A201 4 A201 1 A201 2 1 A301 1 A301 2 A301 2 A301 EXISTING METAL RIDGE CAP TO REMAIN 6 1 / 2 " / 1 2 " 6 1 / 2 " / 1 2 " EXISTING SLATE ROOFING TO REMAIN. CLEAN SURFACE TO REMOVE ALGAE. REPLACE DAMAGED OR MISSING SLATE AFTER STRUCTURAL ALTERATIONS ARE COMPLETE +/ - + / - Seal: SCHEMATIC DESIGN CONSTRUCTION DOCUMENTS PROGRESS: Project Number Date Drawn by Checked by USE OF ARCHITECTS DOCUMENTS: THESE DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT, AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING THE COPYRIGHT(S). THE OWNER SHALL NOT REUSE OR PERMIT THE REUSE OF THESE DOCUMENTS INCLUDING ANY DESIGN & CONSTRUCTION DEVELOPMENT, CHANGES OR ALTERATIONS TO THESE DOCUMENTS, WITHOUT THE WRITTEN ACKNOWLEDGEMENT AND AUTHORIZATION OF THE ARCHITECT Consultant Logo OWNER : 12/10/2025 4:07:27 PM A101 FLOOR AND ROOF PLANS 2420 RUBACKY RESIDENCE - CARRIAGE HOUSE 07.18.25 DC MT PETER & LESLIE RUBACKY 129 CIRCULAR ST. SARATOGA SPRINGS, NY 12866 TBD GENERAL CONTRACTOR: 129 CIRCULAR ST, SARATOGA SPRINGS, NY 12866 1/4" = 1'-0" FIRST FLOOR PLAN11/4" = 1'-0" LOFT PLAN2 1/4" = 1'-0" ROOF PLAN3 1 1 1 No.Description Date 1 REVISED PER PERMIT REVIEW 11.11.2025 2 REVISED PER SLAB CHANGES 12.10.2025 2 2 2 2 POWDER ROOM A702 6 5 4 3 102 103 2' - 1 0 " 3 1 / 2 " 3' - 5 3 / 4 " 1' - 4" 3 1/2" 6' - 10" 8' - 5 1/2" 6' - 7 1 / 4 " 1' - 6 1 / 2 " 30 ' ' V A N I T Y TANKLESS WATER HEATER 1' - 6 1 / 2 " FUTURE 32"x32" SHOWER MIRROR 30'' VANITY T&G. STND. 1x6 BASE TRIM, PTD. T&G, STND. 1x6 BASE TRIM, PTD. TOILET T&G, STND. 1x6 BASE TRIM, PTD. DOOR TO WATER HEATER 1x4 DOOR CASING, STND. 103 T&G, STND. 1x6 BASE TRIM, PTD. 1x4 DOOR CASING, STND. DOOR TO DINING AREA 102 Seal: SCHEMATIC DESIGN CONSTRUCTION DOCUMENTS PROGRESS: Project Number Date Drawn by Checked by USE OF ARCHITECTS DOCUMENTS: THESE DOCUMENTS PREPARED BY THE ARCHITECT ARE INSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT, AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. THE ARCHITECT SHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS INCLUDING THE COPYRIGHT(S). THE OWNER SHALL NOT REUSE OR PERMIT THE REUSE OF THESE DOCUMENTS INCLUDING ANY DESIGN & CONSTRUCTION DEVELOPMENT, CHANGES OR ALTERATIONS TO THESE DOCUMENTS, WITHOUT THE WRITTEN ACKNOWLEDGEMENT AND AUTHORIZATION OF THE ARCHITECT Consultant Logo OWNER : 12/10/2025 4:08:02 PM A702 INTERIOR ELEVATIONS 2420 RUBACKY RESIDENCE - CARRIAGE HOUSE 07.18.25 DC MT PETER & LESLIE RUBACKY 129 CIRCULAR ST. SARATOGA SPRINGS, NY 12866 TBD GENERAL CONTRACTOR: 129 CIRCULAR ST, SARATOGA SPRINGS, NY 12866 MAIN SPACE AXONOMETRIC looking SOUTHWEST1 3/8" = 1'-0" ENLARGED POWDER ROOM PLAN23/8" = 1'-0" POWDER ROOM looking EAST33/8" = 1'-0" POWDER ROOM looking SOUTH4 3/8" = 1'-0" POWDER ROOM looking WEST53/8" = 1'-0" POWDER ROOM looking NORTH6POWDER ROOM AXONOMETRIC looking SW7 INTENTIONALLY BLANK INTENTIONALLY BLANK 1 No.Description Date 1 REVISED PER PERMIT REVIEW 11.11.2025 2 REVISED PER SLAB CHANGES 12.10.2025 2 2