Loading...
HomeMy WebLinkAbout20260091 Lexington Rd & Bemis Heights Rd Subdivision Modification LPS AnalysisPrepared For: Arico Associates 1407 Route 9, Building 2, Suite 6 NYClifton Park 12065 USA Tel:518-573-6989 Fax: Prepared By:M. Crowley December 17, 2025 Y:\SSB\SSB Engineering Data\AE Projects\Bemis Point, NY\Bemis Point, NY.EOne Bemis Point, NY On:Prepared by :December 17, 2025M. Crowley Notes : Analysis based upon drawings and data provided.Station recommendations are preliminary. GPD values impact retention times only, not line sizing or hydraulics. GP laterals to be 1.25". Analysis valid only with pipe type listed . General recommendations for valve placement are: clean out valves at intervals of approximately 1,000 ft and at branch ends and junctions; isolation valves at branch junctions; and air release valves at changes in grade of 20 to 25 ft or more and/or at intervals of 2,000 to 2,500 ft. Lateral kits comprised of a ball and check valve are required to be installed between the pump discharge and street main on all installations. Laterals should be located as close to the public right of way as possible. Quantities of grinder pumps, pipe, and valves are indicated on the cost page. The model of grinder pump(s) indicated is based upon the initial information provided to us but may not be the most appropriate for the specific location or requirements of the project. Costs of these items and their installation are best obtained from sources in your region. We recommend you contact your local distributor of Environment One products for additional recommendations. <<<<< E N D O F N O T E S >>>>> Y:\SSB\SSB Engineering Data\AE Projects\Bemis Point, NY\Bemis Point, NY.EOne December 17, 2025 Budgetary Low Pressure Sewer System Costs Bemis Point, NY Quantity Sub Total Description Unit Cost Installation Valves 1 Clean Out $0.00$0.00 0.00 $0.00 Pumps 12 DH071-93 $0.00$0.00 0.00 12 Lateral Kits (Includes Ball\Check Valve Assembly)$0.00$0.00 0.00 12 Lateral (Boundary) Installation $0.00$0.00 0.00 12 Pump/Panel Installation $0.00$0.00 0.00 600 LF of 1.25" Lateral Pipe $0.00$0.00 0.00 $0.00 Piping 687 2.00" Pipe $0.00$0.00 0.00 410 3.00" Pipe $0.00$0.00 0.00 $0.00 Total Per Connection Total (w/o other)>>>>>>>>>>>>$0.00 $0.00Grand Total Per Connection Grand Total (including other)>>>>>>>>>>>>$0.00 $0.00 Number of Connections 12 Note: The System Costs above are based on piping sized for, and Grinder Pumps manufactured by Environment One Corporation. Page 1 Y:\SSB\SSB Engineering Data\AE Projects\Bemis Point, NY\Bemis Point, NY.EOne PRELIMINARY PRESSURE SEWER-PIPE SIZING AND BRANCH ANALYSIS Prepared By: Bemis Point, NY December 17, 2025M. Crowley Max Main Elevation Minimum Pump Elevation Zone Number Connects to Zone Number of Pumps in Zone Max Sim Ops Accum Pumps in Zone Length of Main this Zone Pipe Size (inches) Max Flow Per Pump (gpm) Gals/day per Pump Max Velocity (FPS) Friction Loss Factor (ft/100 ft) Friction Loss This Zone Accum Fric Loss (feet) Max Flow (GPM) Static Head (feet) Total Dynamic Head (ft) Friction loss calculations were based on a Constant for inside roughness "C"of :This spreadsheet was calculated using pipe diameters for:SDR11HDPE 150 1.00 1.19 4.76 14.65 254.00 247.00 7.00 21.652.00 400.002.0022.00 2.3823311.00200 2.00 2.52 7.23 9.89 254.00 246.00 8.00 17.893.00 287.002.0033.00 3.5736911.00200 3.00 0.65 2.66 2.66 254.00 250.00 4.00 6.663.00 410.003.0044.00 2.19431211.00200 1Page Note: This analysis is valid only with the use of progressive cavity type grinder pumps as manufactured by Environment One. Y:\SSB\SSB Engineering Data\AE Projects\Bemis Point, NY\Bemis Point, NY.EOne PRELIMINARY PRESSURE SEWER-ACCUMULATED RETENTION TIME(HR) Bemis Point, NYPrepared By: M. Crowley December 17, 2025 Length of Zone Average Retention Time (Hr) Accumulated Retention Time(Hr) Connects to Zone Zone Number Average Fluid Changes per Day Accumulated Total of Pumps this Zone Pipe Size (inches)Gallons per 100 lineal feet Capacity of Zone Average Daily Flow This spreadsheet was calculated using pipe diameters for:SDR11HDPE 200Gals per Day per Dwelling 400.00 61.61 600 9.74 2.46 4.431.00 2.00 3 2.00 15.40 287.00 44.21 1,800 40.72 0.59 1.962.00 3.00 9 2.00 15.40 410.00 137.21 2,400 17.49 1.37 1.373.00 3.00 12 3.00 33.47 1Page Note: This analysis is valid only with the use of progressive cavity type grinder pumps as manufactured by Environment One Y:\SSB\SSB Engineering Data\AE Projects\Bemis Point, NY\Bemis Point, NY.EOne