Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20260073 359 Ballston Ave Saratoga Center for the Family Area Varianc Application
Revised $33/,&$7,21)25 ,17(535(7$7,2186(9$5,$1&( $5($9$5,$1&($1'259$5,$1&((;7(16,21 APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in the premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION 1. Property Address/Location: Tax Parcel No.: ________.______ - ______ - ______ (for example: 165.52 – 4 – 37 ) 2. Date acquired by current owner:3. Zoning District when purchased: 4. Present use of property:5. Current Zoning District: 6. Has a previous ZBA application/appeal been filed for this property? Yes (when? For what? ) No 7. Is property located within (check all that apply)?: Historic District Architectural Review District 500’ of a State Park, city boundary, or county/state highway? 8. Brief description of proposed action: Yes No Yes No ,VWKHUHDQDFWLYHZULWWHQYLRODWLRQIRUWKLVSDUFHO" Has the work, use or occupancy to which this appeal relates already begun? Identify the type of appeal you are requesting (check all that apply): INTERPRETATION (p. 2) VARIANCE EXTENSION (p. 2) USE VARIANCE (pp. 3-6) AREA VARIANCE (pp. 6-7) $SSOLFDQW 2ZQHU $WWRUQH\$JHQW3ULPDU\&RQWDFW3HUVRQ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED**[FOR OFFICE USE] _____________BB $SSOLFDWLRQ _________BB_ 'DWHUHFHLYHG @@@@@@@@@@@@@@@@@@@@@@@@@@ 3URMHFW7LWOH &KHFNLI3+5HTXLUHG 6WDII5HYLHZBBBBBBBBBBBBBBB CITY OF SARATOGA SPRINGS =21,1*%2$5'2)$33($/6 &,7<+$//%52$':$< 6$5$72*$635,1*61(:<25. 7(/; ZZZVDUDWRJDVSULQJVRUJ 359 Ballston Avenue Saratoga Springs, NY 12866 (same as Applicant)Saratoga Center for the Family The LA Group, P.C. 40 Long Alley Saratoga Springs, NY 12866 rabre@saratogacff.org mingersoll@thelagroup.com ✔ 359 Ballston Ave, Saratoga Springs 1780416 04/03/2001 SWAD Domestic Violence Shelter/Office UN (T-4) ✔ ✔ ✔ The proposed action is the construction of a single-story standalone expansion structure of ±3,200 SF that will address the Applicant's needs to grow their current services. ✔ (518) 587-8241 ✔ ✔ x303 (518) 587-8100 x218 ✔✔ Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 2 IINTERPRETATION – PLEASE ANSWER THE FOLLOWING (add additional information as necessary): 1. Identify the section(s) of the Zoning Ordinance for which you are seeking an interpretation: Section(s) 2. How do you request that this section be interpreted? 3. If interpretation is denied, do you wish to request alternative zoning relief? Yes No 4. If the answer to #3 is “yes,” what alternative relief do you request? Use Variance Area Variance EXTENSION OF A VARIANCE – PLEASE ANSWER THE FOLLOWING (add additional information as necessary): 1. Date original variance was granted: ________________ 2. Type of variance granted? Use Area 3. Date original variance expired: ____________________ 5. Explain why the extension is necessary. Why wasn’t the original timeframe sufficient? When requesting an extension of time for an existing variance, the applicant must prove that the circumstances upon which the original variance was granted have not changed. Specifically demonstrate that there have been no significant changes on the site, in the neighborhood, or within the circumstances upon which the original variance was granted: N/A N/A N/A Appraisal Assumptions: Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 3 UUSE VARIANCE – PLEASE ANSWER THE FOLLOWING (add additional information as necessary): A use variance is requested to permit the following: For the Zoning Board to grant a request for a use variance, an applicant must prove that the zoning regulations create an unnecessary hardship in relation to that property. In seeking a use variance, New York State law requires an applicant to prove all four of the following “tests”. 1. That the applicant cannot realize a reasonable financial return on initial investment for any currently permitted use on the property. “Dollars & cents” proof must be submitted as evidence. The property in question cannot yield a reasonable return for the following reasons: A. Submit the following financial evidence relating to this property (attach additional evidence as needed): 1) Date of purchase:Purchase amount: $ 2) Indicate dates and costs of any improvements made to property after purchase: Date Improvement Cost 3) Annual maintenance expenses: $4) Annual taxes: $ 5) Annual income generated from property: $ 6) City assessed value: $ Equalization rate: Estimated Market Value: $ 7) Appraised Value: $ Appraiser: Date: N/A N/A Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 4 B. Has property been listed for sale with Yes If “yes”, for how long? _______________________________ the Multiple Listing Service (MLS)?No 1) Original listing date(s): Original listing price: $ If listing price was reduced, describe when and to what extent: 2) Has the property been advertised in the newspapers or other publications?Yes No If yes, describe frequency and name of publications: 3) Has the property had a “For Sale” sign posted on it? Yes No If yes, list dates when sign was posted: 4) How many times has the property been shown and with what results? 2. That the financial hardship relating to this property is unique and does not apply to a substantial portion of the neighborhood. Difficulties shared with numerous other properties in the same neighborhood or district would not satisfy this requirement. This previously identified financial hardship is unique for the following reasons: N/A Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 5 3. That the variance, if granted, will not alter the essential character of the neighborhood. Changes that will alter the character of a neighborhood or district would be at odds with the purpose of the Zoning Ordinance. The requested variance will not alter the character of the neighborhood for the following reasons: 4. That the alleged hardship has not been self-created. An applicant (whether the property owner or one acting on behalf of the property owner) cannot claim “unnecessary hardship” if that hardship was created by the applicant, or if the applicant acquired the property knowing (or was in a position to know) the conditions for which the applicant is seeking relief. The hardship has not been self-created for the following reasons: N/A Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 6 AAREA VARIANCE – PLEASE ANSWER THE FOLLOWING (add additional information as necessary): The applicant requests relief from the following Zoning Ordinance article(s) Dimensional Requirements 'LVWULFW5HTXLUHPHQW 5HTXHVWHG Other: To grant an area variance, the ZBA must balance the benefits to the applicant and the health, safety, and welfare of the neighborhood and community, taking into consideration the following: 1. Whether the benefit sought by the applicant can be achieved by other feasible means. Identify what alternatives to the variance have been explored (alternative designs, attempts to purchase land, etc.) and why they are not feasible. 2. Whether granting the variance will produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. Granting the variance will not create a detriment to nearby properties or an undesirable change in the neighborhood character for the following reasons: VIH[LVWLQJVIQHZ § 240-4.3 Residential mixed-use districts standards. Minimum Building Height Maximum cumulative area of new & existing one-story structure Minimum front build-to zone Minimum build-out percentage 24' 3,000 SF 18' 50% ±12.5' average (11.5' reduction) ±4,000 SF ±248' from PL (230' increase) 0% (100% relief) Concepts for expanding the existing structure were examined and due to the cost constraints and the need to maintain operations during the construction of the new structure, the proposed option is the most viable to achieve the applicant's goals. Interior renovations are anticipated once the new building is completed. Area variance relief would be required for any expansion of the facility due to its existing building site, location and desired function to have patrons enter to the rear of the structure. Granting of the requested variances will not change the character or context of the neighborhood nor will it cause a detriment to the nearby properties which currently are utilized for light industrial, residential, office, and recreational purposes. The proposed new structure will not be visible from the street and will appear as an accessory structure to the main building. Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 7 3. Whether the variance is substantial. The requested variance is not substantial for the following reasons: 4. Whether the variance will have adverse physical or environmental effects on neighborhood or district. The requested variance will not have an adverse physical or environmental effect on the neighborhood or district for the following reasons: 5. Whether the alleged difficulty was self-created (although this does not necessarily preclude the granting of an area variance). Explain whether the alleged difficulty was or was not self-created: The variance requests are designed to not be substantial and are largely due to the change of zoning criteria that has occurred since the initial purchase and approved uses for this site. The rear location and size of the proposed structure has been designed to provide the minimum requirement needed for the operations of the Applicant. The requested variances have been designed to not cause adverse physical or environmental impact to the neighborhood. The proposed structure location is in part located on areas of existing pavement and areas previously disturbed so as to minimize impacts to permeability and impervious areas as well as to preserve existing vegetative buffers and screening to the site. The alleged variances are self-created. However, compliance with the current UDD Zoning dimensional criteria conflicts with the mission, security and operations of this users needs that were revised and approved previously under the SWAD zoning at the time of and initial adaptive reuse of the property and at the time of purchase. Revised ZONING BOARD OF APPEALS APPLICATION FORM PAGE 8 DISCLOSURE Does any City officer, employee, or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? No Yes If “yes”, a statement disclosing the name, resi dence and nature and extent of this interest must be filed with this application. APPLICANT CERTIFICATION I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Zoning Board of Appeals. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. Furthermore, I/we hereby authorize the members of the Zoning Board of Appeals and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this appeal. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Rebecca Abre Digitally signed by Rebecca Abre Date: 2026.01.29 10:25:10 -05'00' 1/29/26 ✔ Revised INSTRUCTIONS AAPPEAL TO THE ZONING BOARD FOR AN INTERPRETATION, USE VARIANCE, AREA VARIANCE AND/OR VARIANCE EXTENSION APPLICATION REQUIREMENTS ELIGIBILITY: To apply for relief from the City’s Zoning Ordinance, an applicant must be the propertyowner(s) or lessee, or have an option to lease or purchase the property in question. The Zoning Board ofAppeals (ZBA) shall not accept any application for appeal that includes a parcel which has a written violationfrom the Zoning and Building Inspector that is not the subject of the application. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure a complete application. TheZBA will only consider properly completed applications that contain original and digital version of the following: Completed application pages 1 and 8, the pages relating to the requested relief (p. 2 for interpretationor extension, pp. 3-5 for use variance, pp. 6-7 for area variance), and any additional supportingmaterials/ documentation. +$1':5,77(1$33/,&$7,216:,//127%($&&(37(' Completed SEQR Environmental Assessment Form – short or long form as required by action. http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf Detailed “to scale” drawings of the proposed project – folded and no larger than 24”x 36”. Identify all existing and proposed structures, lot boundaries and dimensions, and the relationship of structures to the lot dimensions. Also, include any natural or manmade features that might affect your property (e.g., drains, ponds, easements, etc.). Photographs showing the site and subject of your appeal, and its relationship to adjacent properties. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. 3&'&3505)&$633&/5'&&803,4)&&5*/$-6%&%*/5)*4%0$6.&/5 Check City’s website (www.saratoga-springs.org) for meeting dates. CITY OF SARATOGA SPRINGS Z ONING B OARD OF A PPEALS City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550; ZZZVDUDWRJDVSULQJVRUJ Revised ZONING BOARD APPEAL APPLICATION INSTRUCTIONS PAGE 2 PUBLIC HEARING ADVERTISEMENT The Zoning Board of Appeals is required to hold a public hearing on each submitted application within ninety (90) days from when it is determined to be properly complete by City staff. &LW\VWDIIZLOOSUHSDUHDOHJDOQRWLFHIRUWKHSXEOLFKHDULQJDQGDUUDQJHWRKDYHWKHSXEOLFKHDULQJ DQQRXQFHPHQWSULQWHGLQWKHOHJDOQRWLFHVHFWLRQRIDORFDOSXEOLFDWLRQDWOHDVWGD\VEHIRUHWKHKHDULQJ PROPERTY OWNER NOTIFICATION Applicants are required to mail a copy of the public hearing legal notice to all property owners within the following distances from the boundaries of the land in question: Type of variance Distance for property owner notification Use variance 250 feet Area variance & Interpretation 100 feet This notice must be sent at least 7 days but not more than 20 days before the date of the public hearing. City staff will email a copy of the “property owner notification letter” to the applicant. The applicant must then send the notification letter to the nearby property owners. Applicants may not include any other materials in this mailing. The mailing must be certified by the U.S. Post Office. Prior to the public hearing, applicants must present the Post Office “certificates of mailing” to the ZBA. If “certificates of mailing” are not presented prior to the hearing, the hearing will be cancelled. City of Saratoga Springs OFFICE OF PLANNING AND ECONOMIC DEVELOPMENT FEES - 2026 Application to City Council FEE Comprehensive Plan Amendment Zoning Ordinance Amendment Planned Unit Development (PUD) Amendment $1,800 + $300/acre $800 + $300/acre $800 + $300/acre Application to Zoning Board of Appeals FEE Use Variance $1,400 + $75/app Area Variance - Residential (1 & 2 Family) $350/1st var + $75/app + $150/ea add variance Area Variance - 3+ Family and Commercial $1,000/1st var + $75/app + $200/ea add variance Interpretations $650 + $75/app Post Work Application Fee Application Fee x2 + $75/app Variance Extensions 50% of Application Fee + $75/app Application to Design Review Board FEE Demolition Residential Structures - 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $500 $75 Façade Change - removal/addition of windows, doors, $150 Addition or new construction $300 Approval Extension 50% of application fee 3+/Multi-Family, Comm, Mixed-Use Principal or Accessory Structure Materials Change - roof, windows, siding, paint color $150 Façade Change - removal/addition of windows, doors, $150 Addition or new construction $650 Approval Extension 50% of application fee Post Work Application Fee Application Fee x2 Application to Planning Board Special Use Permit $1,200 + $75/app Temporary Use Permit $500 Special Use Permit - Extension $400 Special Use Permit - Modification $550 + $75/app Site Plan Review - incl. PUD Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non-Residential / Mixed-use $800 + $150/1,000 sf (Non-Res) + 250 unit (Res) Administrative SPR Residential $400 Non-Residential / Mixed-use $800 Extension Residential $250 Non-Residential / Mixed-use $350 Subdivision - incl. PUD Sketch Plan $400 per sketch Preliminary Approval Residential: 1-5 Lots $700 + $75/app Residential: 6-10 Lots $1,100 + $75/app Residential: 11-20 Lots $1,450 + $75/app Residential: 21+ Lots $1,800 + $75/app Residential - Extension $350 Final Approval Residential $1,550 + $200/lot + $75/app Non-Residential $2,400/lot + $75/app Final Approval Modification Residential $400 + $75/app Non-Residential $800 + $75/app Final Approval Extension Residential $250 Non-Residential $350 * Subdivisions and Site Plans are subject to Engineering Review- See DPW Fees Demolition $500 Residential Structures – 1 or 2 Family Principal or Accessory Structure Materials Change - roof, windows, siding $75 Façade Change - removal/addition of windows, doors, porch $150 Addition or new construction $300 Approval Extension 50% of Application Fee 3+/Multi-Family, Comm, Mixed-Use Principal or Accessory Structure Equipment Install or Materials Change - roof, windows, siding, paint color $150 Signs, awnings $150 Façade Change - removal/addition of windows, doors, porch $300 Addition or new construction $650 Approval Extension or Modification 50% of Application Fee Post Work Application Fee Application x2 Other Lot Line Adjustment/Subdivision Administrative Action $400 Letter of Credit – Modification Extension $400 Letter of Credit - Collection up to 1% of LoC Recreation Fee $2,000/lot or unit Land Disturbance Activity Permit $750 + $35/acre Watercourse/Wetland Permit $750 Watercourse/Wetland Permit Extension $350 SEQRA EIS Review (Draft & Final) TBD Sidewalk Fee Lieu See DPW Fees Tree Removal Avg. nursery cost in caliper of new species equivalent to diameter at breat height (DBH of tree(s) Removed diameter at breat height (DBH of tree(s) Removed Page 1 of 3 Short Environmental Assessment Form Part 1 - Project Information Instructions for Completing Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part 1 – Project and Sponsor Information Name of Action or Project: Project Location (describe, and attach a location map): Brief Description of Proposed Action: Name of Applicant or Sponsor:Telephone: E-Mail: Address: City/PO: State: Zip Code: 1. Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that may be affected in the municipality and proceed to Part 2. If no, continue to question 2. NO YES 2. Does the proposed action require a permit, approval or funding from any other government Agency? If Yes, list agency(s) name and permit or approval: NO YES 3. a. Total acreage of the site of the proposed action? __________ acres b. Total acreage to be physically disturbed? __________ acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor? __________ acres Check all land uses that occur on,DUHadjoining RU near the proposed actioQ Rural (non-agriculture),ndustrial Commercial Residential (suburban) $TXDWLF 2WKHU6SHFLI\Agriculture Ƒ 8UEDQ Ƒ )RUHVW SEAF 2019 3DUNODQG Saratoga Center for the Family Expansion 359 Ballston Avenue, Saratoga Springs, NY 12866 The proposed action is the request for the necessary variances associated with the proposed construction of a single-story standalone expansion structure of ±3,200 SF that would address the Applicant's need to grow their current services. The new office building would be constructed on the same parcel as the existing Saratoga Center for the Family office and will require area variances for the following four criteria: (1) minimum building height, (2) maximum cumulative area of new and existing one-story structures, (3) minimum front build-to zone, and (4) minimum build-out percentage. Saratoga Center for the Family (518) 587-8241 x303 rabre@saratogacff.org 359 Ballston Avenue Saratoga Springs NY 12866 ✔ ✔ 2.07 ±0.25 2.07 ✔✔✔ ✔ ✔ Page 2 of 3 5. Is the proposed action, a. A permitted use under the zoning regulations? b. Consistent with the adopted comprehensive plan? NO YES N/A 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape?NO YES 7. Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? If Yes, identify: ________________________________________________________________________________ NO YES a. Will the proposed action result in a substantial increase in traffic above present levels? EAre public transportation services available at or near the site of the proposed action? FAre any pedestrian accommodations or bicycle routes available on or near WKHsite of the proposed action? NO YES 9. Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 10. Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable ZDWHU: _________________________________________ _____________________________________________________________________________________________ NO YES 11. Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: ______________________________________ _____________________________________________________________________________________________ NO YES DUFKDHRORJLFDOVLWHVRQWKH1<6WDWH+LVWRULF3UHVHUYDWLRQ2IILFH6+32DUFKDHRORJLFDOVLWHLQYHQWRU\" NO YES D. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? EWould the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: _____________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES D'RHVWKHSURMHFWVLWHFRQWDLQRULVLWVXEVWDQWLDOO\FRQWLJXRXVWRDEXLOGLQJDUFKDHRORJLFDOVLWHRUGLVWULFW ZKLFKLVOLVWHGRQWKH1DWLRQDORU6WDWH5HJLVWHURI+LVWRULF3ODFHVRUWKDWKDVEHHQGHWHUPLQHGE\WKH &RPPLVVLRQHURIWKH1<62IILFHRI3DUNV5HFUHDWLRQDQG+LVWRULF3UHVHUYDWLRQWREHHOLJLEOHIRUOLVWLQJRQWKH 6WDWH5HJLVWHURI+LVWRULF3ODFHV" E ,VWKHSURMHFWVLWHRUDQ\SRUWLRQRILWORFDWHGLQRUDGMDFHQWWRDQDUHDGHVLJQDWHGDVVHQVLWLYHIRU ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ The project parcel is adjacent to the Saratoga Spa State Park Historic District. ✔ ✔ Photo 1: Front of 359 Ballston Avenue taken from the street. Photo 2: Front of 359 Ballston Ave taken at the street from the north, looking south. Photo 3: Front of 359 Ballston Avenue taken at the street from the south, looking north. Photo 4: Back of property at 359 Ballston Ave (area where new building is proposed), taken from the parking lot, looking northwest. Photo 5: Back of property at 359 Ballston Ave (area where new build is proposed), taken from the parking lot, looking south. Photo 6: Main entrance, taken from the parking lot, looking towards Ballston Ave. Photo 7: Main entrance, taken from the parking lot, looking towards Ballston Ave. Photo 8: Back of property at 359 Ballston avenue (area where new build is proposed), taken from the northern parking lot, looking south NEW YORK STATE DEPARTMENT - TRANSPORTATION SARATOGA SPA STATE PARK SARATOGA CENTER FOR THE FAMILY BALL S T O N A V E RTE 5 0 BA L L S T O N A V E RT E 5 0 WE S T A V E ESPEY Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Sa v e D a t e : 1/ 2 8 / 2 0 2 6 1 1 : 1 5 A M Fi l e N a m e : G: \ P r o j - 2 0 2 6 \ 2 0 2 6 0 0 3 _ C e n t e r _ f o r _ t h e _ F a m i l y _ E x p a n s i o n \ 2 0 2 6 0 0 3 C A D \ L 1 _ C o n t e x t . d w g Pl o t t e d B y : LE A H R . C H A R A S H © the LA Group 2026 Saratoga Center for the Family 359 Ballston Avenue Saratoga Springs, NY 12866 Project Title: Drawing Title Drawing No. Description:Date: Project No.: Design: Drawn: Scale: Ch'k'd: 2026003 CMI LRC CMI 01/27/26 1"=100' SITE LOCATION L-1.0 0100 1005020406080 Scale: 1" = 100' Ba l l s t o n A v e n u e Ba l l s t o n A v e n u e PROPOSED NEW STRUCTURE 24' 12 ' 12' 18' 1 2 ' BU I L D - T O Z O N E LIMITS OF WORK LEGEND PARCEL BOUNDARY ZONING SETBACK LIMITS OF WORK Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Sa v e D a t e : 1/ 2 8 / 2 0 2 6 2 : 1 9 P M Fi l e N a m e : G: \ P r o j - 2 0 2 6 \ 2 0 2 6 0 0 3 _ C e n t e r _ f o r _ t h e _ F a m i l y _ E x p a n s i o n \ 2 0 2 6 0 0 3 C A D \ L 3 _ C o n c e p t . d w g Pl o t t e d B y : LE A H R . C H A R A S H © the LA Group 2026 Saratoga Center for the Family 359 Ballston Avenue Saratoga Springs, NY 12866 Project Title: Drawing Title Drawing No. Description:Date: Project No.: Design: Drawn: Scale: Ch'k'd: 2026003 CMI LRC CMI 01/27/26 1"=20' CONCEPT PLAN L-3.0 10 5 10 15 20200 Scale: 1" = 20' Ba l l s t o n A v e n u e 23 0 ' PROPOSED NEW STRUCTURE 24' 12 ' 12' 18' 1 2 ' BU I L D - T O Z O N E LIMITS OF WORK VARIANCE CALCULATIONS VARIANCE (A) Minimum building height (B) Maximum one-story structure square footage (C) Minimum front build-to zone (D) Minimum build-out percentage DISTRICT REQUIREMENT 24' 3,000 SF 18' 50% REQUESTED ±12.5' average (11.5' reduction) ±4,000 SF (800 SF existing, 3200 SF new) ±248' from property line (230' increase) 0% (100% relief) LEGEND PARCEL BOUNDARY ZONING SETBACK LIMITS OF WORK Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Sa v e D a t e : 1/ 2 8 / 2 0 2 6 2 : 0 8 P M Fi l e N a m e : G: \ P r o j - 2 0 2 6 \ 2 0 2 6 0 0 3 _ C e n t e r _ f o r _ t h e _ F a m i l y _ E x p a n s i o n \ 2 0 2 6 0 0 3 C A D \ L 4 _ V a r i a n c e . d w g Pl o t t e d B y : LE A H R . C H A R A S H © the LA Group 2026 Saratoga Center for the Family 359 Ballston Avenue Saratoga Springs, NY 12866 Project 7itle: Drawing 7itle Drawing No. Description:Date: Project No.: Design: Drawn: Scale: Ch'k'd: 2026003 CMI LRC CMI 01/27/26 1"=20' VARIANCE PLAN L-4.0 10 5 10 15 20200 Scale: 1" = 20' A B C D OFFICE 9'-11" x 12'-4" OFFICE 10'-1" x 17'-5" MEDICAL EXAM ROOM 13'-4" x 10'-0" STAFF BATHROOM CLIENT BATHROOM BATHROOM BATHROOM KITCHENETTE CAC RECEPTION LOBBY MECHANICAL JANITOR OFFICE 10'-0" x 12'-4" OFFICE 10'-0" x 12'-4" OFFICE 14'-11" x 12'-4" OFFICE 10'-0" x 10'-0" CONFERENCE ROOM 23'-0" x 20'-11" OBSERVATION ROOM 10'-1" x 9'-11" INTERVIEW ROOM 10'-1" x 10'-6" WAITING WAITING ROOM 10'-10" x 12'-4" 51 2"31 2"31 2"31 2"31 2"31 2"31 2"31 2"31 2"51 2"51 2" 15'-5"10'-7" 5'-61 4"2'-03 4"7'-10"2'-23 4"8'-41 4"4'-43 4"5'-71 4" 10'-0"4'-41 2"8'-81 2"3'-31 2" 2'-1" 4'-2" 2'-1" 41 2" 11'-51 2" 2'-53 4"7'-71 4" 10'-1" 5'-41 4"5'-61 4" 10'-101 2" 88'-111 2" 45 ' - 0 " 24'-8"23'-11" 51 2"51 2"51 2"51 2"31 2" 7'-11 4"6'-113 4"3'-53 4"7'-11 4" 10'-7"14'-1"3'-0"3'-0"17'-11" 7' - 7 " 8'-103 4" 8' - 1 0 3 4" 8' - 1 0 3 4" 8' - 4 7 8" 6' - 3 1 8" 512" 312" 312" 312" 512" 4' - 6 " 3' - 1 " 2' - 1 " 10 ' - 9 1 8" 5' - 2 " 5' - 6 " 5' - 7 1 8" 1' - 1 1 7 8" 11 ' - 1 1 8" 17 ' - 1 1 3 4" 8'-01 8"23'-55 8" 7' - 0 1 2" 512" 312" 312" 512" 5' - 6 5 8" 7' - 4 7 8" 5' - 3 7 8" 5' - 3 7 8" 4' - 2 5 8" 12 ' - 6 " 4' - 8 1 8" 12 ' - 1 1 1 2" 10 ' - 7 3 4" 21 ' - 4 3 4" 45 ' - 0 " 6' - 1 1 8" 312" 13 ' - 1 5 8" 7' - 2 3 8" 20 ' - 4 " 8'-0"8'-51 2"21'-101 4"2'-03 4" BIRCH FLUSH INTERIOR DOOR W/ KD METAL BUCK & SCHLAGE JUPITER CLASSROOM LOCKSET (TYPICAL ALL INTERIOR DOORS) LVT PLANK FLOORING THROUGHOUT (TYPICAL ALL ROOMS EXCEPT LOBBY AND BATHROOMS) ESTIMATE ALTERNATE #1: DELETE PLUMBING FROM STAFF BATHROOM & ESTIMATE AS STORAGE ROOM 8" x 8" DOUGLAS FIR POSTS AND BEAMS (STAIN FINISH) 3" x 8" DOUGLAS FIR PERGOLA RAFTERS @ 32" o.c. (STAIN FINISH) KAWNEER TRIFAB 601T STOREFRONT KAWNEER TRIFAB 601T STOREFRONT KAWNEER TRIFAB 601T STOREFRONT PORCELAIN TILE FLOOR TYP. ALL BATHROOMS ALUMINUM-CLAD WINDOWS (TYP. @ ALL NON-STOREFRONT LOCATIONS) SC A L E : DA T E : RE V I S I O N S : A R C H I T E C T S 4 1 L o n g A l l e y S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 P h o n e : 5 1 8 - 5 8 4 - 7 5 1 4 F a x : 5 1 8 - 5 8 4 - 7 5 2 3 A1.1 SA R A T O G A C T R . F O R T H E F A M I L Y 35 9 B a l l s t o n A v e n u e Sa r a t o g a S p r i n g s , N Y FI R S T F L O O R P L A N 1/ 4 " = 1 ' - 0 " 11 . 2 5 . 2 5 1/4"=1'-0" FIRST FLOOR PLAN1 A1.1 SC A L E : DA T E : RE V I S I O N S : A R C H I T E C T S 4 1 L o n g A l l e y S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 P h o n e : 5 1 8 - 5 8 4 - 7 5 1 4 F a x : 5 1 8 - 5 8 4 - 7 5 2 3 A1.2 SA R A T O G A C T R . F O R T H E F A M I L Y 35 9 B a l l s t o n A v e n u e Sa r a t o g a S p r i n g s , N Y PE R S P E C T I V E S 11 . 1 8 . 2 5 VIEW FROM SOUTHEAST1 A1.2 VIEW FROM NORTHEAST2 A1.2 8" x 8" DOUGLAS FIR POSTS AND BEAMS (STAIN FINISH) 3" x 8" DOUGLAS FIR PERGOLA RAFTERS @ 32" o.c. (STAIN FINISH) 3" x 8" D. FIR RAFTER TAILS @ 32" o.c. 1" x 8" RIPPED COMPOSITE FASCIA 5/4" x 6" FIBER CEMENT CORNER BOARD, BASE TRIM, & CASING 5/4" x 10" FIBER CEMENT FRIEZE JAMES HARDIE ARTISAN SQUARE-CHANNEL SIDING KAWNEER TRIFAB 601T STOREFRONT 3" x 8" D. FIR RAFTER TAILS @ 32" o.c. 1" x 8" RIPPED COMPOSITE FASCIA 5/4" x 6" FIBER CEMENT CORNER BOARD, BASE TRIM, & CASING 5/4" x 10" FIBER CEMENT FRIEZE JAMES HARDIE ARTISAN SQUARE-CHANNEL SIDING KAWNEER TRIFAB 601T STOREFRONT EXPOSED CONCRETE FOUNDATION PRIVACY FILM ON ALL HATCHED WINDOWS 3" x 8" D. FIR RAFTER TAILS @ 32" o.c. 1" x 8" RIPPED COMPOSITE FASCIA 5/4" x 6" FIBER CEMENT CORNER BOARD, BASE TRIM, & CASING 5/4" x 10" FIBER CEMENT FRIEZE JAMES HARDIE ARTISAN SQUARE-CHANNEL SIDING ALUMINUM-CLAD CASEMENT WINDOW EXPOSED CONCRETE FOUNDATION KAWNEER DOOR PRIVACY FILM ON ALL HATCHED WINDOWS SC A L E : DA T E : RE V I S I O N S : A R C H I T E C T S 4 1 L o n g A l l e y S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 P h o n e : 5 1 8 - 5 8 4 - 7 5 1 4 F a x : 5 1 8 - 5 8 4 - 7 5 2 3 A2.1 SA R A T O G A C T R . F O R T H E F A M I L Y 35 9 B a l l s t o n A v e n u e Sa r a t o g a S p r i n g s , N Y EL E V A T I O N S 1/ 4 " = 1 ' - 0 " 11 . 2 5 . 2 5 1/4"=1'-0" EAST ELEVATION1 A2.1 1/4"=1'-0" NORTH ELEVATION2 A2.1 1/4"=1'-0" SOUTH ELEVATION3 A2.1 8" 3' - 1 0 " 9' - 2 5 8" 1' - 6 " 11 ' - 2 " BIRCH FLUSH INTERIOR DOOR W/ KD METAL BUCK & SCHLAGE JUPITER CLASSROOM LOCKSET (TYPICAL ALL INTERIOR DOORS) VINYL BASE MONOPITCH WOOD ROOF TRUSSES @ 24" o.c. 5 8" GWB WALLS & CEILINGS KAWNEER TRIFAB 601T STOREFRONT 3" x 8" D. FIR RAFTER TAILS @ 32" o.c. 1" x 6" T & G V-GROOVE LOOKOUT 60 mil EPDM ROOF 12 1 SC A L E : DA T E : RE V I S I O N S : A R C H I T E C T S 41 L o n g A l l e y S a r a t o g a S p r i n g s , N Y 1 2 8 6 6 P h o n e : 5 1 8 - 5 8 4 - 7 5 1 4 F a x : 5 1 8 - 5 8 4 - 7 5 2 3 A2.1 SA R A T O G A C T R . F O R T H E F A M I L Y 35 9 B a l l s t o n A v e n u e Sa r a t o g a S p r i n g s , N Y RE A R E L E V A T I O N TY P . B U I L D I N G S E C T I O N 1/ 4 " = 1 ' - 0 " 11 . 2 5 . 2 5 1/4"=1'-0" WEST ELEVATION1 A2.2 1/4"=1'-0" BUILDING SECTION2 A2.2 AVERAGE ±12.5 FT