Loading...
HomeMy WebLinkAbout20260069 65 Phila St Construction Application65 Phila Proposed Rear Addition Existing Conditions Southwest South South 61 Phila (left)69 Phila (right) Existing Conditions North Northeast East PROPOSED ADDITION Sure-Seal/Sure-White/Sure-ToughTM EPDM Roofing Systems Adhered, Ballasted and Mechanically Fastened TABLE OF CONTENTS July 2025 Part I-General Page 1.01 Description ........................................................................................................................................................................... 3 1.02 General Design Considerations............................................................................................................................................ 4 1.03 Quality Assurance................................................................................................................................................................ 5 1.04 Submittals ……………………………………………………………………………………………………………………………. ...6 1.05 Warranty…. ......................................................................................................................................................................... 7 Warranty Tables TABLE I – Non-Reinforced EPDM Membrane Thickness for Various Warranty Options ............................................................. 8 TABLE II – Reinforced EPDM Membrane Thickness for Various Warranty Options .................................................................... 9 TABLE III – Mechanically Fastened Roofing Systems Fastening Criteria Up to 20 YR Warranty 22 GA. Steel, Structural Concrete, Wood Plank, and 3/4” Plywood Decks ....................................................................................................................................... 10 TABLE IV – Mechanically Fastened Roofing Systems – Up to 20 YR Warranty – Wood (Plywood or OSB) Decks .................. 11 TABLE V – Re-Roofing Substrate Criteria – Up to 20 YR Warranty ........................................................................................... 12 TABLE VI – Adhered Roofing Systems – Underlayment Fastening Criteria – Up to 20 YR Warranty ........................................ 13 TABLE VII – Adhered SAT EPDM – Underlayment/Fastening – Up to 20 YR Warranty ............................................................ 15 TABLE VIII – Minimum Perimeter Width for Insulation Attachment for All Warranties ............................................................... 16 1.06 Job Conditions ................................................................................................................................................................... 17 1.07 Product Delivery, Storage and Handling ............................................................................................................................ 17 Part II –Product 2.01 General..... ......................................................................................................................................................................... 19 2.02 Membrane………………. .................................................................................................................................................... 19 2.03 Insulation/Underlayments ................................................................................................................................................... 23 2.04 Related Materials ............................................................................................................................................................... 29 2.05 Fastening Components ...................................................................................................................................................... 30 2.06 Insulation Securement Adhesive ....................................................................................................................................... 32 2.07 Vapor / Air Barrier .............................................................................................................................................................. 33 2.08 Edgings/Terminations ......................................................................................................................................................... 34 2.09 Roof Walkways .................................................................................................................................................................. 36 2.10 Other Carlisle Accessories ................................................................................................................................................. 36 Part III-Execution—Adhered, Ballasted and Mechanically Fastened 3.01 General..... ......................................................................................................................................................................... 36 3.02 Roof Deck/Substrate Criteria .............................................................................................................................................. 36 3.03 Insulation/Underlayments ................................................................................................................................................... 39 3.04 Insulation Attachment ......................................................................................................................................................... 39 3.05 Membrane Placement and Securement (including Ballasting) ........................................................................................... 42 3.06 Flashings..... ...................................................................................................................................................................... 51 3.07 Roof Walkways................................................................................................................................................................... 52 3.08 Daily Seal..... ..................................................................................................................................................................... 52 3.09 Optional Color Coating ....................................................................................................................................................... 52 3.10 Clean Up... ......................................................................................................................................................................... 52 ATTACHMENTS “Attachment I” – Ballast Criteria and Walkway - Design “B” Ballasted........................................................................................ 55 “Attachment II” - 25/30 Year Warranty Design Enhancements .................................................................................................. 59 Installation Details... ................................................................................................................................................................... 69 Note: In addition to the information listed in this section Specifiers and Authorized applicators should reference Spec Supplement and Design Reference Sections for other pertinent information. EPDM 7/2025 2 EPDM 7/2025 3 Sure-Seal/Sure-White/Sure-ToughTM EPDM Roofing Systems Adhered, Ballasted and Mechanically Fastened July 2025 The information contained in this generic specification represents a part of Carlisle’s requirements for obtaining a roofing systems warranty. Construction materials and practices, building siting and operation, climatic conditions, and other site-specific factors will have an impact on the performance of the roofing system. Carlisle recommends that the building owner retain a design professional to determine appropriate design measures to be taken in order to address these factors. This section is to serve as criteria for Specifiers and Authorized Applicators regarding the design and installation of Carlisle's Design “A” Adhered, Design “B” Ballasted and Reinforced Mechanically Fastened EPDM Membrane Roofing Systems. Additional information essential for the design and installation of the roof system mentioned herein is also included in the Design Reference Section and also listed in the form of a Specification Supplement at the end of the Technical Manual. Specifiers and Authorized Applicators are advised to reference all applicable sections. Various Warranty Tables have been included in Paragraph 1.05 citing various requirements by which specific warranty coverage can be obtained. Appropriate Warranty Table should be referenced to ensure proper warranty coverage. PART I - GENERAL 1.01 Description A. The Design “A” Adhered Roofing System incorporates Sure-Seal (black) 60- or 90- mil thick non-reinforced or Sure-Seal (gray) 60-mil thick non-reinforced or Sure-White (white) 60- or 90-mil thick non-reinforced or Sure- White (white) 60-mil thick reinforced or 45-, 60- or 75-mil Sure-Tough™ reinforced EPDM membrane. An acceptable insulation is mechanically fastened to the roof deck or adhered with Carlisle supplied urethane-based insulation adhesive or hot asphalt and the EPDM membrane is fully adhered to the insulation with Carlisle EPDM Bonding Adhesive (Sure-Seal Bonding Adhesive, Low-VOC Bonding Adhesive, Water Based Bonding Adhesive and CAV-GRIP III Bonding Adhesive). Adjoining sheets of EPDM membrane are spliced together using 3” or 6” wide SecurTAPE™ and Primer OR Factory-Applied TAPE (FAT™) and Primer. There are no maximum slope restrictions for the application of this roofing system. Note: When non-reinforced EPDM membrane is used, Carlisle recommends a minimum of 60-mil thick material. Sure-Seal FR 45-mil non-reinforced EPDM may be utilized when specified or required by the owner or owner’s representative. Water based adhesive may be used for projects with 20 year maximum warranty and wind speed coverage up to 72 mph. B. The Design “B” Loose Laid Ballasted Roofing System incorporates minimum 45-mil thick Sure-Seal (black) non-reinforced or minimum 60-mil Sure-Tough reinforced EPDM membrane. Both the EPDM membrane and an acceptable membrane underlayment or insulation are loose laid over the substrate and held in place with a minimum of 10 pounds of ballast per square foot depending upon wind load requirements. Adjoining sheets of EPDM membrane are spliced together using 3” or 6” wide SecurTAPE and Primer OR Factory-Applied TAPE (FAT) and Primer. The maximum roof slope for this roofing system is 2" to one horizontal foot. C. The Mechanically Fastened Roofing System incorporates 45-, 60- or 75-mil Sure-Tough or 60-mil Sure-White (white-on-black) reinforced EPDM membrane. An acceptable insulation is mechanically fastened to the roof deck EPDM 7/2025 4 and, depending on project criteria; the reinforced membrane is mechanically fastened with the appropriate Carlisle Fastener and 2" or 2-3/8” diameter Fastening Plates (Polymer Seam Plates required over steel deck) or Fastening Bars at 6" minimum to 12" maximum along the center of the membrane splice. Adjoining sheets of EPDM membrane are spliced together using 6” Factory-Applied TAPE (FAT) and Primer OR 6” SecurTAPE and Primer. Field membrane sheets are either 5’, 6.5’, 8' or 10' wide depending upon wind load requirements, building height and type of roof deck. At the roof perimeter, a heavier fastening density is required utilizing 5’, 6.5' wide sheets or 9" wide Pressure-Sensitive RUSS (Reinforced Universal Securement Strip). The maximum roof slope for this roofing system is 18" in one horizontal foot. This roofing system can also be specified over an existing standing seam, flat seam or corrugated metal roof with the membrane secured to the structural purlins. Refer to the Metal Retrofit System Specification and Details. NOTE: The selection of various components (i.e. insulation, underlayment, membrane thickness, etc.) may vary depending on desired Warranty coverage. Refer to appropriate Warranty Tables listed in Paragraph 1.05. Assemblies with membrane fasteners 12” or longer must be submitted for Carlisle’s review to ensure adequate securement due to the possibility of increased dynamic fastener movement. Such assemblies when accepted may require the use of additional insulation fasteners and the use of 1/2” SecurShield TM HD Recover Board. 1.02 General Design Considerations A. Projects where wind speed coverage greater than 55 mph is specified or those with a 20-year or longer Total System Warranty will require additional enhancements beyond those outlined in this section. Prior to installation, refer to Warranty Tables in Paragraph 1.05. B. Petroleum based products; certain chemicals and waste products (i.e., grease, oil, animal fats, etc.) are not compatible with these roofing systems. Carlisle should be contacted for verification of compatibility and recommendations concerning an acceptable roofing assembly. C. It is the responsibility of the specifier to review local, state and regional codes to determine their impact on the specified Carlisle Roofing System. D. It is the responsibility of the building owner or his/her designated representative to verify structural load limitation. In addition, a core cut may be taken to verify the weight of existing components when the roofing system is to be specified on an existing facility. E. Coordination between various trades is essential to avoid unnecessary rooftop traffic over completed sections of the roof and to prevent subsequent damage to the membrane roofing system. F. Concentrated loads from rooftop equipment may cause deformation of insulation/underlayment and possible damage to the membrane if proper protection is not provided. A protection course or sleepers must be specified. G. Drainage 1. Drainage must be evaluated by the Specifier in accordance with all applicable codes. Slopes may be provided by tapering the structure or through the use of tapered insulation; a sufficient number of roof drains should also be specified and properly located to allow for positive drainage. Significant ponding that could remain after 48 hours should be eliminated with the addition of auxiliary drains in low areas where ponding is anticipated. Carlisle specifically disclaims responsibility for the design and selection of an adequate drainage system and drain accessories. Selection must be made by the building owner or the owner's design professional. 2. Small incidental areas of ponded water will not impact the performance of this roofing system; however, in accordance with industry standards, the roofing assembly should be designed to prevent ponding of water on the roof for prolonged periods (longer than 48 hours). Good roofing practice dictates proper drainage to prevent possible excessive live loads and, in the event of a roof leak, to minimize potential interior damage to the roofing assembly and to the interior of the building. 3. Tapered edge strips, crickets or saddles are recommended where periodic ponding of water may occur. When the slope of the taper exceeds 2" to one horizontal foot additional membrane securement at the base of the tapered edge strip, cricket or saddle will be required. 4. On Sure-White Roofing Systems, a slope greater than 1/8" per horizontal foot is recommended to serve the long-term aesthetics. EPDM 7/2025 5 H. On new construction projects, especially in cold climate regions, moisture generated due to the construction process could adversely impact various components within the roofing assembly if not addressed. Refer to Design Reference DR-01 Construction Generated Moisture” included in the Carlisle Technical Manual. I. Vapor Retarders 1. Carlisle does not require a vapor retarder for the protection of the membrane; however, it should be considered by the specifier for the protection of the roofing assembly (i.e. primarily insulation, underlayment and adhesives). The following criteria should be considered by the specifier: 2. Use of a vapor retarder to protect insulation and reduce moisture accumulation within an insulated roofing assembly, should be investigated by the specifier. 3. In the generally temperate climate of the United States, during the winter months, water vapor flows upward from a heated, more humid interior toward a colder, drier exterior. Vapor retarders are more commonly required in northern climates than in southern regions, where downward vapor pressure may be expected and the roofing membrane itself becomes the vapor retarder. 4. All Carlisle roofing membranes are tested and pass in accordance with ASTM E 2178 and shall qualify as an air barrier when following Carlisle specifications and details for roofing applications. J. On structural concrete decks, when a vapor retarder is not used, gaps in the deck along the perimeter and around penetrations must be sealed along with vertical joints between tilt-up panels, if present, to prevent infiltration of hot humid air and possible moisture contamination resulting from condensation. This is specifically important when polyurethane adhesive is used to attach the roof insulation. NOTE: If left unaddressed, collected moisture could weaken insulation boards and facers resulting in a blow-off or increase the probability of mold growth. K. Retrofit - Recover Projects (when the existing roofing material is left in place) 1. The removal of existing wet insulation and membrane must be specified. The Specifier shall select an appropriate and compatible material as filler for voids created by removal of old insulation or membrane. 2. A core cut should be taken to verify the weight of existing components when the roofing system is to be specified over an existing roofing assembly. 3. Entrapment of water between the old and new membrane can damage and deteriorate new insulation/underlayment between the two membranes. If a vapor retarder or air barrier is not specified, Carlisle recommends the existing membrane be perforated to avoid potential moisture accumulation and to allow the detection of moisture to enable the building owner to take corrective action. This can be accomplished by drilling approximately 3/4" diameter holes every 100 square feet in the existing built-up roof or single-ply membrane (excluding PVC membrane). 4. Existing PVC membrane must be totally removed, or the existing membrane must be cut into maximum 10' by 10' sections. All PVC flashings at the perimeter, roof drains and roof penetrations must be removed. L. Optional Color Coating 1. Sure-Seal X-Tenda Coat Coating is recommended for color coating the EPDM membrane and flashing when required by the Specifier. Available in white or gray. X-Tenda Coat Coating can also be specified as a “Restoration System” when applied to an existing Carlisle EPDM membrane system that may qualify for a 5 or 10-year Coating System Warranty. Refer to Carlisle’s published Sure-Seal X-Tenda Coat Coating Specification for specific requirements. NOTE: Carlisle may be contacted for other optional color coatings. 1.03 Quality Assurance Building codes are above and beyond the intended purpose of this specification. The building owner, owner’s representative or Specifier should verify local codes for applicable requirements and limitations. It is the responsibility of the specifier to review local, state and regional codes to determine their impact on the specified Carlisle Roofing System. EPDM 7/2025 6 NOTE: For code approvals achieved with the Carlisle EPDM Roofing Systems, refer to the Carlisle EPDM Code Approval Guide, DORA (Directory of Roof Assemblies), Factory Mutual (FM) Approval Guide or Underwriters Laboratories (UL) Fire Resistance or Roofing Materials and Systems Directories. A. When recovering or retrofitting an existing roof system, the addition of new insulation (type and thickness) may alter the fire performance characteristics of the assembly. Building owners or their designated representatives shall consult the local code enforcement agency to avoid potential code violation. B. Carlisle recommends the use of Carlisle supplied products for use with these Carlisle Roofing Systems. The performance or integrity of products by others, when selected by the specifier and accepted as compatible by Carlisle, is not the responsibility of Carlisle and is disclaimed by the Carlisle Warranty. C. The specified roofing system must be installed by a Carlisle Authorized Roofing Applicator in compliance with drawings and specifications as approved by Carlisle SynTec. D. Provide polyisocyanurate insulation that meets PIMA Quality Mark Certified LTTR value through third party verification meeting ASTM C 1289, Type II, Class 1, Grade 2. E. There must be no deviations made from Carlisle's specification or Carlisle's approved shop drawings without the PRIOR WRITTEN APPROVAL of Carlisle SynTec. F. After completion of the installation, upon request, an inspection shall be conducted by a Field Service Representative (FSR) of Carlisle SynTec to ascertain that the membrane roofing system has been installed according to Carlisle's published specifications and details applicable at the time of bid. This inspection is to determine whether a warranty shall be issued. It is not intended as a final inspection for the benefit of the owner. G. For ballasted, 30-year warranty projects, the applicator must submit pictures showing the use of EPDM Primer for perimeter RUSS securement or allow random test cuts to confirm the use of EPDM Primer. 1.04 Submittals A. To ensure compliance with Carlisle's minimum warranty requirements, the following projects should be forwarded to Carlisle for review prior to installation, preferably prior to bid. 1. Air pressurized buildings, canopies, and buildings with large openings where the total wall openings exceed 10% of the total wall area on which the openings are located (such as airport hangars, warehouses and large maintenance facilities). Refer to Attachment IV at the end of this section for perimeter considerations, when a Mechanically Fastened System is specified. 2. Cold storage buildings and freezer facilities. 3. Design “A” Adhered Roofing Systems over 250' in height for projects with warranties up to 15 years. 4. Design “A” Adhered Roofing Systems over 100' in height for projects with warranties greater than 15 years. 5. Design “B” Ballasted Roofing System projects over 75' in height. 6. Mechanically Fastened Roofing System projects over 100’ in height. 7. Projects where the EPDM is expected to come in direct contact with petroleum-based products, waste products (i.e., grease, oil, animal fats, etc) and other chemicals. 8. Projects where hot asphalt is specified for insulation attachment. 9. Mechanically Fastened projects specified with a fastener length exceeding 12 inches. B. Shop drawings must be submitted to Carlisle by the Carlisle Authorized Roofing Applicator along with a completely executed Notice of Award (Page 1 of Carlisle's Request for Warranty form) for approval. Approved shop drawings are required for inspection of the roof and on projects where on-site technical assistance is requested. Shop drawings must include: 1. Outline of roof and size 2. Deck type (for multiple deck types) 3. Location and type of all penetrations 4. Perimeter and penetration details 5. Key plan (on multiple roof areas) with roof heights indicated 6. Sheet width and number of perimeter sheets for Reinforced Mechanically Fastened systems 7. Sure-Seal Fastener type, length and maximum spacing (for membrane securement) for Reinforced Mechanically Fastened systems. C. Along with the project submittals (shop drawing and Request for Warranty), the roofing contractor must include pullout test results when the results are below the requirements identified in the Table included in Design Reference DR-06 “Withdrawal Resistance Criteria”. EPDM 7/2025 7 D. Ballasted projects incorporating a lightweight insulating concrete substrate, a certification letter is required from the lightweight insulating concrete manufacturer for the following conditions: 1. The membrane is specified directly over vermiculite or cellular lightweight insulating concrete with a maximum compressive strength of 140 psi. 2. The membrane is specified with HP Protective Mat as the membrane underlayment over vermiculite or cellular lightweight insulating concrete with a compressive strength between 140 - 175 psi. The certification letter must reference the project name and location, accompany the project submittals (shop drawing and Request for Warranty) and contain the following information pertaining to the lightweight insulating concrete mix design: 1. Manufacturer's brand name 2. Maximum compressive strength 3. Average wet density 4. Average air-dry density E. When field conditions necessitate modifications to the originally approved shop drawings, a copy of the shop drawing outlining all modifications must be submitted to Carlisle for revision and approval prior to inspection and warranty issuance. F. As-Built Projects (roofing systems installed prior to project approval by Carlisle) The Carlisle Authorized Applicator may supply Carlisle with an As-Built drawing for a project completed prior to Carlisle's approval. The As-Built drawings: 1. Must conform to Carlisle's most current published specifications and details applicable at the time of bid. 2. Must be submitted along with a completely executed Notice of Completion. 3. Must include the items identified in Paragraphs B, C and D above. Note: As-Built projects are not recommended for those projects referenced in Paragraph A in order to ensure Carlisle warranty requirements have been met. G. Notice of Completion (Page 2 of the Carlisle Request for Warranty form) After project completion, a Notice of Completion must be submitted to Carlisle to schedule the necessary inspection and acceptance of the project prior to issuance of the Carlisle warranty. 1.05 Warranty A. A Total System Warranty is available for roofing systems on commercial buildings within the United States and applies only to products manufactured or marketed by Carlisle SynTec. The total system is defined as membrane, flashings, adhesives, sealants and other Carlisle brand products utilized in the installation. For a complete description of these products, refer to the Part 2 “Products” Section in this Specification and Spec Supplement “Related Products” P-01. B. See Tables Below for information regarding Warranted Systems and Design Criteria: 1. TABLE I – Non-Reinforced EPDM Membrane Thickness for Various Warranty Options Identifies minimum membrane thickness for non-reinforced membranes used in adhered or ballasted roofing systems. 2. TABLE II – Reinforced EPDM Membrane Thickness for Various Warranty Options Identifies minimum membrane thickness required for adhered and mechanically fastened assemblies using Reinforced Membrane. 3. TABLE III – Mechanically Fastened Roofing Systems - Membrane Fastening Criteria – Up to 20 YR Warranty - Steel/Concrete Decks Identifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The assemblies are categorized based on various building height and specific wind speed warranty coverage. 4. TABLE IV – Mechanically Fastened Roofing Systems - Membrane Fastening Criteria – Up to 20 YR Warranty - Wood (Plywood & OSB) Decks Identifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The assemblies are categorized based on various building height and specific wind speed warranty coverage. 5. TABLE V – Re-roofing Substrate Criteria - Up to 20 YR Warranty Identifies required substrates for re- roofing applications for adhered, mechanically fastened and ballasted roofing systems. 6. TABLE VI – Adhered Roofing Systems - Underlayment Fastening Criteria - Up to 20 YR Warranty Identifies required underlayment for adhered roofing systems with Warranties up to 20 year based on the EPDM 7/2025 8 various wind speed coverage available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. 7. TABLE VII – Adhered Roofing Systems – Underlayment Fastening Criteria - 25 to 30 YR Warranty Identifies required underlayment for adhered roofing systems with Warranties from 25 to 30 year based on the various wind speed coverage available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. Table I Non-Reinforced EPDM Membrane Thickness for Various Warranty Options SURE-SEAL OR SURE-WHITE NON-REINFORCED MEMBRANES - ADHERED Warranty Duration Warranty Wind Speed Coverage Minimum Membrane Thickness Hail Coverage 55, 72 or 80 mph 90 to 100 mph 110 to 120 mph *(Cover Board set in Adhesive) 5,10, or 15 year √ √ N/A 60-mil Sure-Seal OR Sure-White 60-mil Sure-Seal SAT OR Sure- White SAT 1" for Adhered* 20 year √ √ N/A 60-mil Sure-Seal OR Sure-White 60-mil Sure-Seal SAT OR Sure- White SAT 1" for Adhered* 25 year (3) √ (1) √ (1) N/A 60-mil Sure-Seal OR Sure-White 60-mil Sure-Seal SAT OR Sure- White SAT 1" for Adhered* 30 year (3) √ (1) √ (1) N/A 90-mil Sure-Seal OR Sure-White 2" for Adhered* SURE-SEAL OR SURE-WHITE NON-REINFORCED MEMBRANES - BALLASTED Warranty Duration Warranty Wind Speed Coverage Minimum Membrane Thickness Hail Coverage 55, 72 or 80 mph 5,10, 15, 20 or 25 year (3) √ (2) Sure-Seal 45-mil 1" for Ballasted 5,10, 15 or 20 year √ (2) 60-mil Sure-Seal OR Sure-White 2" for Ballasted 25 or 30 year (3) √ (2) 60-mil Sure-Seal OR Sure-White 2" for Ballasted 30 year (3) √ (2) 90-mil Sure-Seal OR Sure-White 3" for Ballasted Notes: N/A = Not Acceptable √= Acceptable (1) Standard 90-8-30A, EPDM x-23 Low-VOC, Low-VOC EPDM/TPO or CAV-GRIP III Bonding Adhesive must be utilized. (2) When Sure-Tough Reinforced membrane is specified, 60-mil membrane minimum is required for warranties for up to 20 year. Projects with 25 / 30 Year Warranty must incorporate 75-mil membrane. (3) See Attachment II '25/30 Year Warranty Design Enhancements' for enhanced design requirements. EPDM 7/2025 9 Table II Reinforced EPDM Membrane Thickness for Various Warranty Options Warranty Duration Sure-Tough or Sure-White Reinforced Membranes Warranty Wind Speed Coverage Minimum Membrane Thickness Hail Coverage Puncture Coverage 55, 72 or 80 mph 90 mph 100 to 120 mph *(Cover Board set in Adhesive) Adhered Mech. Fastened Adhered Mech. Fastened Adhered Mech. Fastened 5,10, or 15 year √ √ √ √ √ N/A 45-mil Sure-Tough N/A 8 man hours 20 year √ √ √ √ √ N/A 60-mil Sure-Tough, 60-mil Sure-White Reinforced, 60-mil Sure-Tough SAT OR 60-mil Sure-White SAT 1" for Adhered* 16 man hours 25 year (2) √ (1) √ √ (1) √ √ (1) N/A 75-mil Sure-Tough OR 75-mil Sure- Tough SAT 2" for Adhered* 32 man hours 30 year (2) √ (1) √ √ (1) √ √ (1) N/A 75-mil Sure-Tough 2" for Adhered* 32 man hours Notes: N/A = Not Acceptable √= Acceptable (1) Standard 90-8-30A, EPDM x-23 Low-VOC, Low-VOC EPDM/TPO or CAV-GRIP III Bonding Adhesive must be utilized. (2) See Attachment II '25/30 Year Warranty Design Enhancements' for enhanced design requirements. (3) Carlisle’s Accidental Puncture Warranty covers labor hours and material used during the repair. Maximum labor and material hours are dependent upon system design. Refer to the Warranty Availability Quick Reference Guide for coverage. EPDM 7/2025 10 Table III Mechanically Fastened Roofing Systems Fastening Criteria Up to 20 YR Warranty (1) 22 GA. Steel, Structural Concrete, Wood Plank, and 3/4” Plywood Decks Peak Gust Wind Speed Warranty Max. Building Height Min. Number of Perimeter Sheets Field Membrane Width Perimeter Sheet Width Fastening Density* (Field & Perimeter Sheets) Building Distance from Coastline Greater than 7 miles 3 to 7 miles Less than 3 miles 55 MPH Up to 60' 1 2 3 10' 6.5' 12" O.C. 8' 6.5' 12" O.C. 61' to 100' 2 2 3 10' 6.5' 6" O.C.** 8' 6.5' 12" O.C. 72 MPH Up to 60' 2 2 3 10' 6.5' 12" O.C. 8' 6.5' 12" O.C. 61' to 100' 3 4 4 10' 6.5' 6" O.C.** 8' 6.5' 12" O.C. 80 MPH Up to 60' 3 3 4 10' 5'*** 12" O.C. 8' 5'*** 12" O.C. 61' to 100' 3 4 4 10' 5’*** 6" O.C.** 8' 5'*** 12" O.C. 90 MPH (1) Up to 60' 3 4 4 10' 5'*** 6" O.C.** 8' 5'*** 12" O.C. 61' to 100' 4 5 5 10' 5'*** 6" O.C. ** 8' 5'*** 12" O.C. * Using HP Fasteners on Steel Deck, Wood Plank and ¾” Plywood Decks with Polymer Seam Plates **12" o.c. Spacing can be utilized by using HP-Xtra Fasteners and 2-3/8” Polymer Seam Plates. ***As an option, 9" wide EPDM Pressure Sensitive RUSS can be used beneath the field sheets for perimeter securement. (1) 20 year is the maximum warranty available with peak gust wind speed of 90 MPH. Projects with greater wind speed coverage MUST be submitted to Carlisle for review and possible considerations. EPDM 7/2025 11 EPDM Membrane Fastening Criteria (Up to 20 Year Warranty – Up to 60’ Building Height) for Mechanically Fastening Roofing Systems Wood (Plywood or OSB) Decks TABLE IV Wood (Plywood or OSB) Decks Peak Gust Wind Speed Warranty Deck Type Projected Pull-Out Values Min. Number of Perimeter Sheets Field Membrane Width Perimeter Sheet Width Fastening Density (Field & Perimeter Sheets) Building Distance from Coastline Greater than 7 miles 3 to 7 miles Less than 3 miles 55 MPH 7/16" OSB 210 lbs 2 3 3 10' 5'* 9" O.C. 2 3 3 8' 5'* 12" O.C. 15/32" 3-Ply Plywood 240 lbs 2 2 3 8' 5'* 12" O.C. 15/32" 5-Ply Plywood 530 lbs 1 2 3 10' 6.5' 12" O.C. 5/8" OSB 310 lbs 2 3 3 10' 5'* 12" O.C. 2 3 3 8' 5'* 12" O.C. 72 MPH 15/32" 3-Ply Plywood 240 lbs 2 2 3 8' 5'* 12" O.C. 15/32" 5-Ply Plywood 530 lbs 2 2 3 10' 6.5' 12" O.C. 5/8" OSB 310 lbs 2 3 3 10' 5'* 12" O.C. 2 3 3 8' 5'* 12" O.C 80 MPH Contact Carlisle for Approval and Evaluation *Maximum duration for OSB NOT to exceed 20 Years. EPDM 7/2025 12 Table V Re-roofing Substrate Criteria - Up to 20 YR Warranty Acceptable Roof Deck/Substrate EPDM Membrane (See Table I and II for minimum membrane thickness) RETROFIT / NO TEAR-OFF Adhered - Design "A" Ballasted - Design "B" Mechanically Fastened Existing Smooth Surface BUR or Mineral Surface Cap Sheet Direct Application Insulation Direct Application Gravel Surfaced BUR Insulation Insulation Insulation Coal Tar Pitch Insulation Insulation Insulation Modified Bitumen Direct Application Insulation Direct Application Existing Single-Ply Insulation Insulation Direct Application (1) Sprayed-in-place Urethane Complete Tear-off Required Insulation Complete Tear-off Required (1) Direct application over existing PVC is not permitted regardless of warranty duration. Carlisle may be contacted for specific substrate requirement. NOTE: Projects with Warranties greater than 20 YR require total removal of existing materials. Refer to Table VI and VII for further material requirements. NOTE: Refer to Roof Deck and Substrate Criteria Table in Part III for additional installation requirements. EPDM 7/2025 13 Table VI Adhered Roofing Systems Underlayment Fastening Criteria Up to 20 YR Warranty Other Requirements are Listed in Additional Design Considerations following this Table All Carlisle Products listed for higher wind speed coverage can also be used for Warranties for lower speed coverage. (i.e. 72 MPH underlayment may be used for 55 MPH underlayment) Maximum Peak Gust Wind Speed Warranty Minimum Membrane Underlayment Underlayment Attachment Metal Edging # of Fasteners per 4' x 8' board size Adhesive Ribbon Spacing for 4' x 4' size board Field Perimeter 55 or 72 MPH 1" (20 psi) Polyisocyanurate or 1” (20 psi) Polyisocyanurate Eco 16 12" (4)(5)(10) 6" (4) SecurEdge Drip Edge 1-1/2" (20 psi) Polyisocyanurate or 1-1/2” (20 psi) Polyisocyanurate Eco 10 2" (20 psi) Polyisocyanurate Or 2” (20 psi) Polyisocyanurate Eco 8 1/2” SecurShield HD or 1/2” SecurShield HD Eco (1) 12 1/4” DensDeck Prime, 1/4” Securock, or 1/4” DEXcell FA VSHTM, 1/4” Securock Ultralight Coated Glass Mat (1) 12 80 MPH 1/2” SecurShield HD Plus (1) 8 12" (4)(5)(6)(10) 6' (4)(6) SecurEdge Drip Edge (9) 1/2" HP Recovery Board (1)(11) 16 1/2” SecurShield HD and 1/2” SecurShield HD Eco (1) 16 2” SecurShield HD Composite 6 1/2" DensDeck Prime, 1/2” Securock (1), or 1/2” DEXcell FA VSHTM, 1/2” Securock Ultralight Coated Glass-Mat Board 8 1-1/2" Polyisocyanurate (25-psi) Or 1-1/2” (25 psi) Polyisocyanurate Eco 10 2" (25 -psi) Polyisocyanurate Or 2” (25 psi) Polyisocyanurate Eco 8 90 MPH 1/2" DensDeck Prime, 1/2” Securock, or 1/2” DEXcell FA VSHTM, 1/2” Securock Ultralight Coated Glass-Mat (1) 12 6" (8) 6" (6)(7) SecurEdge Drip Edge (2)(3) or SecurEdge EX Drip Edge or SecurEdge Snap- On Fascia 1/2" SecurShield HD, 1/2” SecurShield HD Eco, or 1-1/2" (20-psi) SecurShield Polyiso or 1-1/2” (20-psi) SecurShield Eco (1) 16 1/2” SecurShield HD Plus or 1/2” EcoStorm VSH (1) 12 2" (20-psi) SecurShield, 2” (20 psi) SecurShield Eco or 2” SecurShield HD Polyiso Composite (1) 8 1-1/2” StormBase (OSB/Polyiso Composite) 8 1-1/2” Insulfoam HD Composite 16 100 MPH 2” (25-psi) SecurShield Polyiso or 2” (25 psi) SecurShield Eco 16 FS FS SecurEdge Drip Edge (2)(3) or SecurEdge EX Drip Edge or SecurEdge Snap- On Fascia 110 MPH 1-1/2” StormBase (OSB/Polyiso Composite) or 1/2” EcoStorm VSH (1) 16 FS FS SecurEdge EX Drip Edge or SecurEdge Snap- On Fascia 1/2” SecurShield HD Plus (1) 120 MPH 5/8" DensDeck Prime, 5/8” DensDeck StormX Prime, 5/8” Securock or 5/8” Securock Ultralight Coated Glass- Mat (1) 16 FS FS SecurEdge EX Drip Edge or SecurEdge Snap- On Fascia 1-1/2” StormBase (OSB/Polyiso Composite) or 1/2” EcoStorm VSH (1) 17 1/2” SecurShield HD Plus (1) 24 2” SecurShield HD Composite 16 FS = Full Spray or Ribbons @ 4" O.C. (1) For Steel Decks, cover boards must be installed over a min. 1" thick approved Carlisle Insulation. EPDM 7/2025 14 (2) Carlisle HP or HP-X Fasteners must be used to secure SecurEdge Snap-On Canted Fascia to perimeter wood nailers. (3) Membrane securement is required at the base of the SecurEdge Drip Edge waterdam. (4) Gravel Surface BUR - Field @ 6" O.C. / Perimeter @ 4" O.C. (5) Steel Decks - Field & Perimeter @ 6" O.C. (6) Cementitious Wood Fiber - Field @ 6" O.C. / Perimeter @ 4" O.C. (7) Smooth BUR - Field @ 6" O.C. / Perimeter @ 4" O.C. (8) Gravel Surface BUR – FS (9) May be fastened with ring shank nails staggered 4" on center. Carlisle HP or HP-X Fasteners may also be used fastened 12" on center. (10) Gypsum Deck must have a minimum 6” o.c. bead spacing. (11) HP Recovery Board cannot exceed 15 YR. warranty for Reroof and No Tear-off projects only. Table VI - Additional Adhered Design Considerations - Up to 20 YR Warranty 1 – For Building heights between 51-100', enhance 12'-wide perimeter with 50% more fasteners and plates. 2 - Building height shall not exceed 100'* 3- Acceptable decking: 22-gauge or heavier steel, structural concrete, 1-1/2" wood plank, or 15/32" plywood.** 4- See DR-05 for insulation fastening patterns. * For projects where building height exceeds 100', please submit to Carlisle for review. ** 16 fasteners per 4’ x 8’ board are required for the following decks: OSB, gypsum, cementitious, wood fiber (Tectum), lightweight insulated concrete over steel roof deck thinner than 22-gauge and steel roof deck thinner than 22-gauge. Warranties are limited to a 20-year, 72-mph wind speed. W-HG-1Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Product Selection Guide Size and Performance Data .................................................................................................................W-HG-2 Features and Options ...........................................................................................................................W-HG-3 Combination Assemblies ...................................................................................................................................W-HG-4 Glazing Performance ..........................................................................................................................................W-HG-6 Grille Types Grille Profiles ........................................................................................................................................W-HG-10 Grille Patterns .......................................................................................................................................W-HG-11 Size Tables for Double- and Single-Hung .....................................................................................................W-HG-12 Cottage Sash Units .............................................................................................................................W-HG-14 Replacement Units ..............................................................................................................................W-HG-15 Design Data Miscellaneous Formulas ....................................................................................................................W-HG-19 Double- and Single-Hung .................................................................................................................W-HG-20 Replacement Units ..............................................................................................................................W-HG-25 Detailed Product Descriptions .......................................................................................................................W-HG-30 Unit Sections Wood Collection ..................................................................................................................................W-HG-32 Double-, and Single-Hung Clad .......................................................................................................W-HG-33 Single- and Double-Hung Wood .....................................................................................................W-HG-39 The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information. Supporting documents for this product: (Link path included for easy copy/paste sharing, click on links to open document or access by visiting Pella.com) Test Reports: https://media.pella.com/professional/adm/CertificationReports/Test_Reports_PR-Clad. pdf?utm_source=pdfdoc CSI Specs (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Wood-CSI_Specs/08552-R.rtf ?utm_source=pdfdoc AIA Masterspec (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Wood-CSI_Specs/Masterspec/085200_fl.doc?utm_ source=pdfdoc Detailed Product Description (readable using Microsoft Word or other text editing application): Clad: https://media.pella.com/professional/adm/Clad-Wood/PR-DoubleHung-C.rtf?utm_ source=pdfdoc Wood: https://media.pella.com/professional/adm/Clad-Wood/PR-DoubleHung-W.rtf?utm_ source=pdfdoc Size Tables (requires appropriate CAD software to read and use): https://media.pella.com/professional/adm/Clad-Wood/ASCDHEV_D.dwg?utm_source=pdfdoc CAD cross sections (requires appropriate CAD software to read and use): Clad: https://media.pella.com/professional/adm/Clad-Wood/ASRM5DH3_D.dwg?utm_ source=pdfdoc Wood: https://media.pella.com/professional/adm/Clad-Wood/ASWM4DHRPT3b.dwg?utm_ source=pdfdoc 3D & BIM (requires appropriate software to read and use): https://media.pella.com/professional/adm/RevitFiles/PR-Revit/Window-Double_Hung-Pella- Reserve-Traditional.zip?utm_source=pdfdoc Sketchup (requires appropriate software to read and use): https://media.pella.com/professional/adm/Clad-Wood/PellaSKP_PellaReserve_Traditional_ Double-Hung.zip?utm_source=pdfdoc Combination Recommendations: https://media.pella.com/professional/adm/Clad-Wood/D_Combinations.pdf?utm_ source=pdfdoc Installation Details: https://media.pella.com/professional/adm/Clad-Wood/F_InstallationDetails.pdf?utm_ source=pdfdoc Impact-Resistant Double-Hung, Complete Product Information: https://media.pella.com/professional/adm/Clad-Wood/Pella-ImpactResistant_DoubleHung. pdf?utm_source=pdfdoc Bay/Bow Details: https://media.pella.com/professional/adm/Clad-Wood/Pella-Wood_BayBowWindows. pdf?utm_source=pdfdoc Microsoft and Microsoft Word are registered trademarks of Microsoft Corp. W-HG-2Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (—) = Not Available (1) Maximum performance for single unit when glazed with the appropriate glass thickness. See Design Data pages in this section for specific product performance class and grade values. (2) Published performance data for air infiltration is determined by testing a minimum of four (4) products of NFRC model size. Testing is conducted in accordance with ASTM E283. Air infiltration ratings for products will differ by size. The performance data does not apply to combination assemblies unless noted. Actual product performance may vary for a number of reasons including installation and product care. (3) The higher the level, the greater the product’s ability to resist forced entry. (4) Glazing configurations may result in higher operational forces (5) ASTM E 1425 defines standard sizes for acoustical testing. Ratings achieved at that size are representative of all sizes of the same configuration. Other Performance Criteria Forced Entry Resistance Level (Minimum Security Grade) 3 10 Operating Force (lb) Initiate Motion / Maintain Motion (of Hallmark tested size and glazing) 4 40/45 Air/Water/Structural Performance 1 Meets or Exceeds AAMA / WDMA Ratings H-CW30 - CW50 Hallmark Certified Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure) 2 0.11 Water Resistance 4.6 – 7.5 psf Design Pressure 30 – 50 psf Size and Performance Data Sound Transmission Class / Outdoor-Indoor Transmission Class Product Frame Size Tested 5 Glazing System STC Rating OITC RatingOverall Glazing Thickness Exterior Glass Thickness Interior Glass Thickness Third Pane Thickness Clad Double-Hung Window WITHOUT GRILLES 45" x 65"11/16"2.5 mm 2.5 mm —28 24 47" x 59"11/16"5 mm 3 mm —31 27 45" x 65"11/16"3 mm 6 mm PVB —33 28 Wood Double-Hung Window WITHOUT GRILLES 45" x 65"11/16"2.5 mm 2.5 mm —26 22 45" x 65"11/16"3 mm 3 mm —29 24 03/19/2025 W-HG-3Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (—) = Not Available (1) Contact your local Pella sales representative for current designs and color options. (2) Only available for Pella Reserve products with triple glazing. Not available with high altitude glazing. (3) Available with Low-E argon-insulated glass only. (4) Antique Brass, Distressed Nickel, Distressed Bronze finishes available for Historical spoon-style lock only. Standard Options / Upgrades Glazing Glazing Type Dual-Pane Insulating Glass — Insulated Glass Options/Low-E Types Advanced Low-E SunDefense™ Low-E SunDefense+ Low-E AdvancedComfort Low-E NaturalSun Low-E NaturalSun+ Low-E Clear (no Low-E coating) Additional Glass Options Annealed Glass Tempered Glass Obscure Glass 1 Low-E Tinted Glass (Bronze, Gray and Green) Non-Impact Laminated Dual-Pane Insulating Glass Gas Fill/High Altitude Argon High altitude Exterior Exterior Sash Profile Ogee Putty Glaze Exterior Finish EnduraClad® aluminum-clad exterior EnduraClad Plus protective finish, Factory Primed Pine wood exterior, Unfinished Mahogany wood exterior Cladding Colors Standard colors 1 Feature Colors, Custom Colors 1 Interior Unfinished wood Factory primed Factory prefinished paint 1 Factory prefinished stain 1 Wood Types Pine Mahogany, Douglas Fir Hardware Hardware Types Sash lifts, Cam-action lock Simulated lock Air conditioner lock Historical spoon-style lock (surface mounted) Hardware Finishes Champagne, White, Brown or Matte Black Satin Brass, Satin Nickel, Oil-Rubbed Bronze, Distressed Bronze, Distressed Nickel 4 Tilt-Wash Cleaning Tilt to interior on both sashes — Grilles Integral Light Technology® Grilles —Traditional, Prairie, Top Row, Cross, New England, Victorian, Diamond, Custom Grilles-Between-the-Glass —Traditional, Prairie, Top Row 1 , Cross, Custom-Equally Divided Screens —Integrated Rolscreen® - retractable screen, InView™ screens, in standard roll-form or premium extruded aluminum frame Features and Options Rev. 10/20/2023 W-HG-4Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Combinations are a great way to create visual interest in any project. A combination is an assembly formed by two or more separate windows or doors whose frames are mulled together by a combination or reinforcing mullion. Pella window combinations are available in an endless variety of arrangements. Below are some examples of factory-assembled combinations. See the Combinations Recommendations document for typical mullions, requirements and limitations. Contact your local Pella sales representative for more information. Combination Assemblies - Rectangular Units W-HG-5Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Combinations are a great way to create visual interest in any project. A combination is an assembly formed by two or more separate windows or doors whose frames are mulled together by a combination or reinforcing mullion. Pella window combinations are available in an endless variety of arrangements, below are some examples. See the Combinations Recommendations document for typical mullions, requirements and limitations. Contact your local Pella sales representative for more information. Combination Assemblies - Arch Top Units W-HG-6Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. Visit www.energystar.gov for Energy Star guidelines. Non Rectangular Unit thermal values will vary slightly. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Glazing Performance - Total Unit Climate Zones CA Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent Dual-Pane Glazing - Aluminum-Clad Exterior N NC SC S CA 11/16"Clear IG PEL-N-232-01105-00001 2.5 2.5 air 0.46 0.60 0.62 44 with grilles-between-the-glass PEL-N-232-01106-00001 0.46 0.53 0.55 44 with integral grilles PEL-N-232-01107-00001 0.46 0.53 0.55 44 11/16"Clear IG PEL-N-232-01109-00001 3 3 air 0.46 0.58 0.61 44 with grilles-between-the-glass PEL-N-232-01110-00001 0.46 0.52 0.55 44 with integral grilles PEL-N-232-01111-00001 0.46 0.52 0.55 44 11/16"Advanced Low-E IG PEL-N-232-01141-00001 2.5 2.5 argon 0.29 0.28 0.53 60 with grilles-between-the-glass PEL-N-232-01142-00001 0.29 0.25 0.47 60 with integral grilles PEL-N-232-01143-00001 0.29 0.25 0.47 60 11/16"Advanced Low-E IG PEL-N-232-01145-00001 3 3 argon 0.29 0.28 0.52 59 with grilles-between-the-glass PEL-N-232-01146-00001 0.29 0.25 0.46 59 with integral grilles PEL-N-232-01147-00001 0.29 0.25 0.46 59 11/16"SunDefense™ Low-E IG PEL-N-232-01189-00001 2.5 2.5 argon 0.28 0.21 0.49 60 SC S with grilles-between-the-glass PEL-N-232-01190-00001 0.28 0.19 0.43 60 SC S with integral grilles PEL-N-232-01191-00001 0.29 0.19 0.43 60 S 11/16"SunDefense™ Low-E IG PEL-N-232-01193-00001 3 3 argon 0.28 0.21 0.48 59 SC S with grilles-between-the-glass PEL-N-232-01194-00001 0.28 0.19 0.43 59 SC S with integral grilles PEL-N-232-01195-00001 0.29 0.19 0.43 59 S 11/16"SunDefense+ Low-E IG PEL-N-232-01813-00001 2.5 2.5 argon 0.25 0.20 0.48 49 NC SC S with grilles-between-the-glass PEL-N-232-01814-00001 0.25 0.18 0.42 49 NC SC S with integral grilles PEL-N-232-01815-00001 0.25 0.18 0.42 49 NC SC S 11/16"SunDefense+ Low-E IG PEL-N-232-01821-00001 3 3 argon 0.25 0.20 0.47 48 NC SC S with grilles-between-the-glass PEL-N-232-01822-00001 0.25 0.18 0.42 48 NC SC S with integral grilles PEL-N-232-01823-00001 0.26 0.18 0.42 48 SC S 11/16"AdvancedComfort Low-E IG PEL-N-232-01165-00001 2.5 2.5 argon 0.25 0.28 0.52 48 NC with grilles-between-the-glass PEL-N-232-01166-00001 0.25 0.25 0.46 48 NC with integral grilles PEL-N-232-01167-00001 0.26 0.25 0.46 48 11/16"AdvancedComfort Low-E IG PEL-N-232-01169-00001 3 3 argon 0.25 0.27 0.51 47 NC with grilles-between-the-glass PEL-N-232-01170-00001 0.25 0.25 0.45 47 NC with integral grilles PEL-N-232-01171-00001 0.26 0.25 0.45 47 11/16"NaturalSun Low-E IG PEL-N-232-01117-00001 2.5 2.5 argon 0.30 0.52 0.60 59 with grilles-between-the-glass PEL-N-232-01118-00001 0.30 0.47 0.53 59 with integral grilles PEL-N-232-01119-00001 0.30 0.47 0.53 59 11/16"NaturalSun Low-E IG PEL-N-232-01121-00001 3 3 argon 0.30 0.52 0.59 58 with grilles-between-the-glass PEL-N-232-01122-00001 0.30 0.46 0.53 58 with integral grilles PEL-N-232-01123-00001 0.30 0.46 0.53 58 11/16"NaturalSun+ Low-E IG PEL-N-232-01781-00001 2.5 2.5 argon 0.26 0.48 0.58 47 N 35 CA with grilles-between-the-glass PEL-N-232-01782-00001 0.26 0.43 0.52 47 N with integral grilles PEL-N-232-01783-00001 0.27 0.43 0.52 47 11/16"NaturalSun+ Low-E IG PEL-N-232-01789-00001 3 3 argon 0.26 0.47 0.58 46 N 34 CA with grilles-between-the-glass PEL-N-232-01790-00001 0.26 0.42 0.51 46 N with integral grilles PEL-N-232-01791-00001 0.26 0.42 0.51 46 N Rev. 11/15/2023 W-HG-7Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. Visit www.energystar.gov for Energy Star guidelines. Non Rectangular Unit thermal values will vary slightly. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Glazing Performance - Total Unit Climate Zones CA Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Tinted Glazing N NC SC S CA 11/16"Bronze Advanced Low-E IG PEL-N-232-01225-00002 5 3 argon 0.29 0.25 0.34 58 with grilles-between-the-glass PEL-N-232-01226-00002 0.31 0.23 0.30 58 S with integral grilles PEL-N-232-01227-00002 0.30 0.23 0.30 58 S 11/16"Gray Advanced Low-E IG PEL-N-232-01225-00003 5 3 argon 0.29 0.23 0.29 58 S with grilles-between-the-glass PEL-N-232-01226-00003 0.31 0.21 0.26 58 S with integral grilles PEL-N-232-01227-00003 0.30 0.21 0.26 58 S 11/16"Green Advanced Low-E IG PEL-N-232-01225-00004 5 3 argon 0.29 0.28 0.46 58 with grilles-between-the-glass PEL-N-232-01226-00004 0.31 0.25 0.41 58 with integral grilles PEL-N-232-01227-00004 0.30 0.25 0.41 58 Vent Dual-Pane High Altitude Glazing - Aluminum-Clad Exterior 11/16" Advanced Low-E IG PEL-N-232-01153-00001 2.5 2.5 air 0.32 0.28 0.53 56 with grilles-between-the-glass PEL-N-232-01154-00001 0.32 0.25 0.47 56 with integral grilles PEL-N-232-01155-00001 0.33 0.25 0.47 56 11/16" Advanced Low-E IG PEL-N-232-01157-00001 3 3 air 0.32 0.28 0.52 55 with grilles-between-the-glass PEL-N-232-01158-00001 0.32 0.25 0.46 55 with integral grilles PEL-N-232-01159-00001 0.33 0.25 0.46 55 11/16"SunDefense™ Low-E IG PEL-N-232-01201-00001 2.5 2.5 air 0.32 0.21 0.49 56 S with grilles-between-the-glass PEL-N-232-01202-00001 0.32 0.19 0.43 56 S with integral grilles PEL-N-232-01203-00001 0.33 0.19 0.43 56 S 11/16"SunDefense™ Low-E IG PEL-N-232-01205-00001 3 3 air 0.32 0.21 0.48 55 S with grilles-between-the-glass PEL-N-232-01206-00001 0.32 0.19 0.43 55 S with integral grilles PEL-N-232-01207-00001 0.33 0.19 0.43 55 11/16"SunDefense+ Low-E IG PEL-N-232-01809-00001 2.5 2.5 air 0.27 0.21 0.48 44 SC S with grilles-between-the-glass PEL-N-232-01810-00001 0.27 0.19 0.42 44 SC S with integral grilles PEL-N-232-01811-00001 0.28 0.19 0.42 44 SC S 11/16"SunDefense+ Low-E IG PEL-N-232-01817-00001 3 3 air 0.27 0.21 0.47 44 SC S with grilles-between-the-glass PEL-N-232-01818-00001 0.27 0.19 0.42 44 SC S with integral grilles PEL-N-232-01819-00001 0.28 0.19 0.42 43 SC S 11/16"AdvancedComfort Low-E IG PEL-N-232-01177-00001 2.5 2.5 air 0.27 0.28 0.52 44 with grilles-between-the-glass PEL-N-232-01178-00001 0.27 0.25 0.46 44 with integral grilles PEL-N-232-01179-00001 0.28 0.25 0.46 44 11/16"AdvancedComfort Low-E IG PEL-N-232-01181-00001 3 3 air 0.28 0.27 0.51 43 with grilles-between-the-glass PEL-N-232-01182-00001 0.28 0.25 0.45 43 with integral grilles PEL-N-232-01183-00001 0.28 0.25 0.45 43 11/16"NaturalSun Low-E IG PEL-N-232-01129-00001 2.5 2.5 air 0.33 0.52 0.60 56 with grilles-between-the-glass PEL-N-232-01130-00001 0.33 0.47 0.53 56 with integral grilles PEL-N-232-01131-00001 0.34 0.47 0.53 55 11/16"NaturalSun Low-E IG PEL-N-232-01133-00001 3 3 air 0.33 0.51 0.59 55 with grilles-between-the-glass PEL-N-232-01134-00001 0.33 0.46 0.52 55 with integral grilles PEL-N-232-01135-00001 0.34 0.46 0.52 55 11/16"NaturalSun+ Low-E IG PEL-N-232-01777-00001 2.5 2.5 air 0.28 0.48 0.58 43 with grilles-between-the-glass PEL-N-232-01778-00001 0.28 0.43 0.52 43 with integral grilles PEL-N-232-01779-00001 0.29 0.43 0.52 43 11/16"NaturalSun+ Low-E IG PEL-N-232-01785-00001 3 3 air 0.28 0.47 0.58 43 with grilles-between-the-glass PEL-N-232-01786-00001 0.28 0.42 0.51 43 with integral grilles PEL-N-232-01787-00001 0.29 0.42 0.51 42 Rev. 11/15/2023 W-HG-8Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. Visit www.energystar.gov for Energy Star guidelines. Non Rectangular Unit thermal values will vary slightly. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Glazing Performance - Total Unit Climate Zones CA Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent Dual-Pane Glazing - Wood Exterior N NC SC S CA 11/16"Clear IG PEL-N-234-01105-00001 2.5 2.5 air 0.45 0.60 0.62 44 with grilles-between-the-glass PEL-N-234-01106-00001 0.45 0.54 0.56 44 with integral grilles PEL-N-234-01107-00001 0.45 0.54 0.56 44 11/16"Clear IG PEL-N-234-01109-00001 3 3 air 0.45 0.59 0.62 43 with grilles-between-the-glass PEL-N-234-01110-00001 0.45 0.53 0.55 43 with integral grilles PEL-N-234-01111-00001 0.46 0.53 0.55 43 11/16"Advanced Low-E IG PEL-N-234-01141-00001 2.5 2.5 argon 0.28 0.28 0.53 59 with grilles-between-the-glass PEL-N-234-01142-00001 0.28 0.25 0.47 59 with integral grilles PEL-N-234-01143-00001 0.29 0.25 0.47 59 11/16"Advanced Low-E IG PEL-N-234-01145-00001 3 3 argon 0.28 0.28 0.52 58 with grilles-between-the-glass PEL-N-234-01146-00001 0.28 0.25 0.47 58 with integral grilles PEL-N-234-01147-00001 0.29 0.25 0.47 58 11/16"SunDefense™ Low-E IG PEL-N-234-01189-00001 2.5 2.5 argon 0.28 0.21 0.49 60 SC S with grilles-between-the-glass PEL-N-234-01190-00001 0.28 0.19 0.44 60 SC S with integral grilles PEL-N-234-01191-00001 0.28 0.19 0.44 60 SC S 11/16"SunDefense™ Low-E IG PEL-N-234-01193-00001 3 3 argon 0.28 0.21 0.49 59 SC S with grilles-between-the-glass PEL-N-234-01194-00001 0.28 0.19 0.43 59 SC S with integral grilles PEL-N-234-01195-00001 0.28 0.19 0.43 59 SC S 11/16"SunDefense+ Low-E IG PEL-N-234-01813-00001 2.5 2.5 argon 0.24 0.21 0.48 49 NC SC S with grilles-between-the-glass PEL-N-234-01814-00001 0.24 0.19 0.43 49 NC SC S with integral grilles PEL-N-234-01815-00001 0.25 0.19 0.43 49 NC SC S 11/16"SunDefense+ Low-E IG PEL-N-234-01821-00001 3 3 argon 0.24 0.21 0.47 47 NC SC S with grilles-between-the-glass PEL-N-234-01822-00001 0.24 0.19 0.42 47 NC SC S with integral grilles PEL-N-234-01823-00001 0.25 0.19 0.42 47 NC SC S 11/16"AdvancedComfort Low-E IG PEL-N-234-01165-00001 2.5 2.5 argon 0.24 0.28 0.52 48 NC with grilles-between-the-glass PEL-N-234-01166-00001 0.24 0.25 0.46 48 NC with integral grilles PEL-N-234-01167-00001 0.25 0.25 0.46 48 NC 11/16"AdvancedComfort Low-E IG PEL-N-234-01169-00001 3 3 argon 0.24 0.28 0.51 47 NC with grilles-between-the-glass PEL-N-234-01170-00001 0.24 0.25 0.46 47 NC with integral grilles PEL-N-234-01171-00001 0.25 0.25 0.46 47 NC 11/16"NaturalSun Low-E IG PEL-N-234-01117-00001 2.5 2.5 argon 0.29 0.53 0.60 59 34 CA with grilles-between-the-glass PEL-N-234-01118-00001 0.29 0.47 0.53 59 with integral grilles PEL-N-234-01119-00001 0.30 0.47 0.53 59 11/16"NaturalSun Low-E IG PEL-N-234-01121-00001 3 3 argon 0.29 0.52 0.59 58 with grilles-between-the-glass PEL-N-234-01122-00001 0.29 0.46 0.53 58 with integral grilles PEL-N-234-01123-00001 0.30 0.46 0.53 58 11/16"NaturalSun+ Low-E IG PEL-N-234-01781-00001 2.5 2.5 argon 0.25 0.48 0.59 47 N 36 CA with grilles-between-the-glass PEL-N-234-01782-00001 0.25 0.43 0.52 47 N with integral grilles PEL-N-234-01783-00001 0.26 0.43 0.52 47 N 11/16"NaturalSun+ Low-E IG PEL-N-234-01789-00001 3 3 argon 0.25 0.47 0.58 46 N 35 CA with grilles-between-the-glass PEL-N-234-01790-00001 0.25 0.42 0.52 46 N with integral grilles PEL-N-234-01791-00001 0.26 0.42 0.52 46 N Rev. 11/15/2023 W-HG-9Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. Visit www.energystar.gov for Energy Star guidelines. Non Rectangular Unit thermal values will vary slightly. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Glazing Performance - Total Unit Climate Zones CA Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Tinted Glazing N NC SC S CA 11/16"Bronze Advanced Low-E IG PEL-N-234-01225-00002 5 3 argon 0.29 0.25 0.34 57 with grilles-between-the-glass PEL-N-234-01226-00002 0.30 0.23 0.30 57 S with integral grilles PEL-N-234-01227-00002 0.30 0.23 0.30 57 S 11/16"Gray Advanced Low-E IG PEL-N-234-01225-00003 5 3 argon 0.29 0.23 0.29 57 S with grilles-between-the-glass PEL-N-234-01226-00003 0.30 0.21 0.26 57 S with integral grilles PEL-N-234-01227-00003 0.30 0.21 0.26 57 S 11/16"Green Advanced Low-E IG PEL-N-234-01225-00004 5 3 argon 0.29 0.28 0.46 57 with grilles-between-the-glass PEL-N-234-01226-00004 0.30 0.25 0.41 57 with integral grilles PEL-N-234-01227-00004 0.30 0.25 0.41 57 Vent Dual-Pane High Altitude Glazing - Wood Exterior 11/16" Advanced Low-E IG PEL-N-234-01153-00001 2.5 2.5 air 0.31 0.28 0.53 56 with grilles-between-the-glass PEL-N-234-01154-00001 0.31 0.26 0.47 56 with integral grilles PEL-N-234-01155-00001 0.32 0.26 0.47 56 11/16" Advanced Low-E IG PEL-N-234-01157-00001 3 3 air 0.32 0.28 0.52 55 with grilles-between-the-glass PEL-N-234-01158-00001 0.32 0.26 0.47 55 with integral grilles PEL-N-234-01159-00001 0.33 0.26 0.47 55 11/16"SunDefense™ Low-E IG PEL-N-234-01201-00001 2.5 2.5 air 0.31 0.21 0.49 56 S with grilles-between-the-glass PEL-N-234-01202-00001 0.31 0.19 0.44 56 S with integral grilles PEL-N-234-01203-00001 0.32 0.19 0.44 56 S 11/16"SunDefense™ Low-E IG PEL-N-234-01205-00001 3 3 air 0.31 0.21 0.49 55 S with grilles-between-the-glass PEL-N-234-01206-00001 0.31 0.19 0.43 55 S with integral grilles PEL-N-234-01207-00001 0.32 0.19 0.43 55 S 11/16"SunDefense+ Low-E IG PEL-N-234-01809-00001 2.5 2.5 air 0.26 0.21 0.48 45 SC S with grilles-between-the-glass PEL-N-234-01810-00001 0.26 0.19 0.43 45 SC S with integral grilles PEL-N-234-01811-00001 0.27 0.19 0.43 45 SC S 11/16"SunDefense+ Low-E IG PEL-N-234-01817-00001 3 3 air 0.27 0.21 0.47 43 SC S with grilles-between-the-glass PEL-N-234-01818-00001 0.27 0.19 0.42 43 SC S with integral grilles PEL-N-234-01819-00001 0.28 0.19 0.42 43 SC S 11/16"AdvancedComfort Low-E IG PEL-N-234-01177-00001 2.5 2.5 air 0.27 0.28 0.52 44 with grilles-between-the-glass PEL-N-234-01178-00001 0.27 0.25 0.46 44 with integral grilles PEL-N-234-01179-00001 0.27 0.25 0.46 44 11/16"AdvancedComfort Low-E IG PEL-N-234-01181-00001 3 3 air 0.27 0.28 0.51 43 with grilles-between-the-glass PEL-N-234-01182-00001 0.27 0.25 0.46 43 with integral grilles PEL-N-234-01183-00001 0.28 0.25 0.46 43 11/16"NaturalSun Low-E IG PEL-N-234-01129-00001 2.5 2.5 air 0.32 0.53 0.60 55 with grilles-between-the-glass PEL-N-234-01130-00001 0.32 0.47 0.53 55 with integral grilles PEL-N-234-01131-00001 0.33 0.47 0.53 55 11/16"NaturalSun Low-E IG PEL-N-234-01133-00001 3 3 air 0.33 0.52 0.59 54 with grilles-between-the-glass PEL-N-234-01134-00001 0.33 0.46 0.53 54 with integral grilles PEL-N-234-01135-00001 0.33 0.46 0.53 54 11/16"NaturalSun+ Low-E IG PEL-N-234-01777-00001 2.5 2.5 air 0.27 0.48 0.59 44 with grilles-between-the-glass PEL-N-234-01778-00001 0.27 0.43 0.52 44 with integral grilles PEL-N-234-01779-00001 0.28 0.43 0.52 43 11/16"NaturalSun+ Low-E IG PEL-N-234-01785-00001 3 3 air 0.28 0.47 0.58 42 with grilles-between-the-glass PEL-N-234-01786-00001 0.28 0.42 0.52 42 with integral grilles PEL-N-234-01787-00001 0.28 0.42 0.52 42 Rev. 11/15/2023 W-HG-10Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window 2" 3/4" Wood Exterior - Wood Interior Putty Glaze and Ogee Grilles 7/8"5/8"1 1/4" Clad Exterior - Wood Interior Putty Glaze and Ogee Grilles 7/8"5/8"1 1/4" Grilles-Between-the-Glass ®Traditional Style Collection - Integral Light Technology Clad Exterior - Wood Interior Ogee Grilles 2" 1 1/4"7/8" Contoured 3/4" Interior wood ILT grilles available in Pine, Mahogany or Douglas Fir to match complete unit. Exterior wood ILT grilles available in Pine or Mahogany to match complete unit. Grille Profiles W-HG-11Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window For traditional patterns, see size tables. Integral light technology® Grilles Prairie Lite Patterns Other Available Patterns Grilles-Between-the-Glass Pella Reserve single-hung windows are available in custom shapes shown below, and additional shapes per drawing. For specifications, size limitations, and details on these units, contact your local Pella sales representative. Grille Patterns Standard corner lite dimension for Prairie patterns = 2-1/2" VG. Available in transoms ≥ 1'3" height and width. Available in all standard and special sizes. VG = Visible Glass Lite dimensions noted can vary. For size and pattern availability contact your local Pella sales representative. Prairie - Standard corner lite dimension for Prairie patterns = 2-1/2" VG. - Available in transoms ≥ 1'3" height and width. Cross - Minimum DH frame height 35". - Horizontal bar will be at 1/2" of the VG height of the top sash. Top Row - Minimum DH frame height 35". - Horizontal bar will be at 1/2" of the VG height of the top sash. Custom shapes W-HG-12Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Opening Dimensions Clad Exterior Units: Dimensions shown in standard size tables are rough opening dimensions. Wood Exterior Units: Use frame dimension plus dimensions below. This dimension includes the use of standard 1-1/8" wood subsill. Frame Rough Masonry Brickmould Width Height Width Height STD + 3/4"+1-7/8"+ 3-1/8"+ 3-1/8" 3-1/2" + 3/4"+1-7/8"+ 6-3/8"+ 4-3/4" For clad and wood units with impact-resistant glass, see the product installation instructions or refer to local building code requirements. Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. See Design Data pages in this section for clear opening dimensions. Clear opening (egress) information does not take into consideration the addition of a Rolscreen (or any other accessory) to the product. Consult your local building code to ensure products with Rolscreens meet egress requirements.4584418437843384298425842184 4884 4877 48714571417137713371297125712171 2177 2577 2977 3377 3777 4177 4577 4865 4859 4857 4853 4847 4841 48352135 2535 2935 3335 3735 4135 4535 4541414137413341294125412141 2147 2547 2947 3347 3747 4147 4547 4553415337533353295325532153 2157 2557 2957 3357 3757 4157 4557 4559415937593359295925592159 2165 2565 2965 3365 3765 4165 4565 4817 4825 48144514411437143314291425142114 2117 2517 2917 3317 3717 4117 4517 4525412537253325292525252125 4" 3 / 4" 3 / 4" 3 / 7' 0 " (2 1 5 3 ) 7' 0 (2 1 3 4 ) (1 8 0 3 ) 5' 1 1 (1 8 2 2 ) 5' 1 1 " (1 9 5 6 ) 6' 5 (1 9 7 5 ) 6' 5 " 4" 3 / 4" 3 / 4" 3 / 4" 3 / 4" 3 / 4" 3 / 4" 3 / 4' 9 (1 4 4 8 ) (1 4 6 7 ) 4' 9 " 2' 1 1 " (8 8 9 ) 2' 1 1 (9 0 8 ) (1 1 9 4 ) 3' 1 1 (1 2 1 3 ) 3' 5 3' 5 " (1 0 6 0 ) (1 0 4 1 ) 3' 1 1 " (1 3 4 6 ) 4' 5 (1 3 6 5 ) (1 4 9 9 ) 4' 1 1 (1 5 1 8 ) 4' 5 " 4' 1 1 " 5' 5 (1 6 5 1 ) (1 6 7 0 ) 5' 5 " Vent Units 4" 3 / 4" 3 / 4"3 /4"3 /4"3 /4"3 /4"3 /4"3 /4"3 / 4" 3 / 4"3 / Frame Opening 1' 9 1' 9" (552) (533) 2' 1 2' 1" (654) (635) 2' 5 2' 5" (756) (737) (959) 3' 1 3' 1" (940) (857) 2' 9" 2' 9 (838) 3' 5 3' 5" (1 060) (1 041) (1 162) 3' 9 3' 9" (1 143) (1 219) 4' 0" 4' 0 (1 238) 1' 2 " (3 7 5 ) 1' 2 (3 5 6 ) (4 3 2 ) 1' 5 (4 5 1 ) 1' 5 " 2' 1 (6 3 5 ) (6 5 4 ) 2' 1 " Fixed Transoms E E E E E E E E E E EEEEEE E E 1E 1E EEE E EE EEE EE E 1E 1E Pella Reserve single-hung windows are available in shapes shown above, and additional custom shapes per drawing. For specifications, size limitations, and details on these units, contact your local Pella sales representative. Springline Arch Head Partial Arch Head Left Right Size Tables - Equal Sash W-HG-13Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Grille patterns will align with companion hung window with equal sash split. 5-lite high grille patterns may be ordered in 5'5" fixed units to match cottage sash vent units. Grilles are equally-divided on fixed units with odd-number lites high. 5959535947594159 4135 4141 4147 4153 4157 4165 4171 4735 4741 4747 4753 4757 4765 4771 5335 5341 5347 5353 5357 5365 5371 5935 5941 5947 5953 5957 5965 5971 Fixed Units 4" 3/ (1 4 9 9 ) (1 5 1 8 ) 4' 1 1 " 4' 1 1 "4 /3 4" 3/ Frame Opening "4/34"3/"4/34"3/4' 5 4' 5" (1 365) (1 346)(1 499) (1 518) 4' 11 4' 11"3' 11" 3' 11 (1 213) (1 194)(1 041) (1 060) 3' 5" 3' 5 "4 /3 "4 / 3 4" 3/ 4" 3/ "4 / 3 (1 8 0 3 ) (1 8 2 2 ) 5' 1 1 " 5' 1 1 (1 6 5 1 ) (1 6 7 0 ) 5' 5 " 5' 5 4' 9 4' 9 " (1 4 6 7 ) (1 4 4 8 ) 4' 5 4' 5 " (1 3 6 5 ) (1 3 4 6 ) (1 0 4 1 ) (1 0 6 0 ) 3' 5 " 3' 5 2' 1 1 " 2' 1 1 (9 0 8 ) (8 8 9 ) (1 1 9 4 ) (1 2 1 3 ) 3' 1 1 " 3' 1 1 Opening Dimensions Clad Exterior Units: Dimensions shown in standard size tables are rough opening dimensions. Wood Exterior Units: Use frame dimension plus dimensions below. This dimension includes the use of standard 1-1/8" wood subsill. Frame Rough Masonry Brickmould Width Height Width Height STD + 3/4"+1-7/8"+ 3-1/8"+ 3-1/8" 3-1/2" + 3/4"+1-7/8"+ 6-3/8"+ 4-3/4" For clad and wood units with impact-resistant glass, see the product installation instructions or refer to local building code requirements. Size Tables - Fixed W-HG-14Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Cottage units have unequal sash split. Sash glass ratio is 40% upper sash to 60% Lower sash. Vent variable units have unequal sash split. Sash glass ratio is determined by checkrail heights. See unit sections for dimension requirements. 6 Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. See Design Data pages in this section for clear opening dimensions. Clear opening (egress) information does not take into consideration the addition of a Rolscreen (or any other accessory) to the product. Consult your local building code to ensure products with Rolscreens meet egress requirements. Size Tables - Cottage Sash Opening Dimensions Clad Exterior Units: Dimensions shown in standard size tables are rough opening dimensions. Wood Exterior Units: Use frame dimension plus dimensions below. This dimension includes the use of standard 1-1/8" wood subsill. Frame Rough Masonry Brickmould Width Height Width Height STD + 3/4"+1-7/8"+ 3-1/8"+ 3-1/8" 3-1/2" + 3/4"+1-7/8"+ 6-3/8"+ 4-3/4" For clad and wood units with impact-resistant glass, see the product installation instructions or refer to local building code requirements. W-HG-15Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. See Design Data pages in this section for clear opening dimensions. Clear opening (egress) information does not take into consideration the addition of a Rolscreen (or any other accessory) to the product. Consult your local building code to ensure products with Rolscreens meet egress requirements. Size Tables - Replacement Equal Sash Sizes W-HG-16Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. See Design Data pages in this section for clear opening dimensions. Clear opening (egress) information does not take into consideration the addition of a Rolscreen (or any other accessory) to the product. Consult your local building code to ensure products with Rolscreens meet egress requirements. Size Tables - Replacement Sizes W-HG-17Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. See Design Data pages in this section for clear opening dimensions. Clear opening (egress) information does not take into consideration the addition of a Rolscreen (or any other accessory) to the product. Consult your local building code to ensure products with Rolscreens meet egress requirements. Size Tables - Replacement Cottage Sash Sizes W-HG-18Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Not to scale. Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. Size Tables - Replacement Fixed Sizes W-HG-19Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Traditional grille patterns shown. Refer to Grille Types section for additional patterns and profiles. * Some units with custom glazing may have limited travel. Integrated Rolscreen® is only available on sizes greater than or equal to 34" tall and 21" wide and less than or equal to 84" tall and 48" wide. See your local Pella sales representative for specific size information. Special Size Frame Dimensions* Sash configuration Vent-Equal Cottage Fixed Sash Glass Ratio Top % : Bottom %50 : 50 40 : 60 NA Shortest Unit Frame Size 24-3/8" (619) 40-1/4" (1 022) 17" (432) Tallest Unit Frame Size 96" (2 438) 81" (2 057) 71" (1 803) Unit Frame Width Range 14" to 48" (356 to 1 219) 14" to 48" (356 to 1 219) 17" to 59" (432 to 1 499) Opening Dimensions Clad Exterior Units: Dimensions shown in standard size tables are rough opening dimensions. Wood Exterior Units: Use frame dimension plus dimensions below. This dimension includes the use of standard 1-1/8" wood subsill. Frame Rough Masonry Brickmould Width Height Width Height STD + 3/4"+1-7/8"+ 3-1/8"+ 3-1/8" 3-1/2" + 3/4"+1-7/8"+ 6-3/8"+ 4-3/4" For clad and wood units with impact-resistant glass, see the product installation instructions or refer to local building code requirements. Vent Units Fixed and Transom Units Visible Glass Width = Frame - 5.647"Width = Frame - 5.75" Height = (Frame - 8.681") ÷ 2 Height = Frame - 5.75" Actual Glass Width = Frame - 4.375"Width = Frame - 4.375" Height = (Frame - 5.983") ÷ 2 Height = Frame - 4.375" Clear Opening* COW = Frame Width - 3.4375"— COH = (Frame Height ÷ 2) - 4.4375"— Vent Area Ft 2 (COW x COH) ÷ 144 — Equal Sash Rectangular Only Special Sizes and Dimensions W-HG-20Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (1) Maximum design pressure when glazed with appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Vent Equal Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening (Inches)Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width (Inches) Height (Inches)Annealed Tempered Clad Wood 2135 17-5/16 13-1/16 1.6 2.8 2.5 3 CW50 CW45 2141 17-5/16 16-1/16 1.9 3.4 2.5 3 CW50 CW45 2147 17-5/16 19-1/16 2.3 4.1 2.5 3 CW50 CW45 2153 17-5/16 22-1/16 2.7 4.7 2.5 3 CW50 CW45 2157 17-5/16 24-1/16 2.9 5.2 2.5 3 CW50 CW45 2159 17-5/16 25-1/16 3.0 5.4 2.5 3 CW50 CW45 2165 17-5/16 28-1/16 3.4 6.0 2.5 3 CW50 CW45 2171 17-5/16 31-1/16 3.7 6.6 2.5 3 CW50 CW45 2177 17-5/16 34-1/16 4.1 7.3 2.5 3 CW50 CW45 2184 17-5/16 37-9/16 4.5 8.0 2.5 3 CW40 CW40 2535 21-5/16 13-1/16 1.9 3.5 2.5 3 CW50 CW45 2541 21-5/16 16-1/16 2.4 4.3 2.5 3 CW50 CW45 2547 21-5/16 19-1/16 2.8 5.1 2.5 3 CW50 CW45 2553 21-5/16 22-1/16 3.3 6.0 2.5 3 CW50 CW45 2557 21-5/16 24-1/16 3.6 6.5 2.5 3 CW50 CW45 2559 21-5/16 25-1/16 3.7 6.8 2.5 3 CW50 CW45 2565 21-5/16 28-1/16 4.2 7.6 2.5 3 CW50 CW45 2571 21-5/16 31-1/16 4.6 8.4 2.5 3 CW50 CW45 2577 E1 21-5/16 34-1/16 5.0 9.2 2.5 3 CW50 CW45 2584 E1 21-5/16 37-9/16 5.6 10.1 2.5 3 CW40 CW40 2935 25-5/16 13-1/16 2.3 4.3 2.5 3 CW50 CW45 2941 25-5/16 16-1/16 2.8 5.2 2.5 3 CW50 CW45 2947 25-5/16 19-1/16 3.4 6.2 2.5 3 CW50 CW45 2953 25-5/16 22-1/16 3.9 7.2 2.5 3 CW50 CW45 2957 25-5/16 24-1/16 4.2 7.8 2.5 3 CW50 CW45 2959 25-5/16 25-1/16 4.4 8.2 2.5 3 CW50 CW45 2965 25-5/16 28-1/16 4.9 9.1 2.5 3 CW50 CW45 2971 E1 25-5/16 31-1/16 5.5 10.1 2.5 3 CW50 CW45 2977 E 25-5/16 34-1/16 6.0 11.1 2.5 3 CW50 CW45 2984 E 25-5/16 37-9/16 6.6 12.2 2.5 3 CW40 CW40 3335 29-5/16 13-1/16 2.7 5.0 2.5 3 CW50 CW45 3341 29-5/16 16-1/16 3.3 6.1 2.5 3 CW50 CW45 3347 29-5/16 19-1/16 3.9 7.3 2.5 3 CW50 CW45 3353 29-5/16 22-1/16 4.5 8.4 2.5 3 CW50 CW45 3357 29-5/16 24-1/16 4.9 9.2 2.5 3 CW50 CW45 3359 E1 29-5/16 25-1/16 5.1 9.6 2.5 3 CW50 CW45 3365 E 29-5/16 28-1/16 5.7 10.7 2.5 3 CW50 CW45 3371 E 29-5/16 31-1/16 6.3 11.8 2.5 3 CW50 CW45 3377 E 29-5/16 34-1/16 6.9 13.0 2.5 3 CW50 CW45 3384 E 29-5/16 37-9/16 7.7 14.3 2.5 3 CW40 CW40 Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. Continued on next page Design Data W-HG-21Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. Vent Equal Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening (Inches)Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width (Inches) Height (Inches)Annealed Tempered Clad Wood 3735 33-5/16 13-1/16 3.0 5.7 2.5 3 CW50 CW45 3741 33-5/16 16-1/16 3.7 7.0 2.5 3 CW50 CW45 3747 33-5/16 19-1/16 4.4 8.3 2.5 3 CW50 CW45 3753 33-5/16 22-1/16 5.1 9.6 2.5 3 CW50 CW45 3757 E1 33-5/16 24-1/16 5.6 10.5 2.5 3 CW50 CW45 3759 E 33-5/16 25-1/16 5.8 11.0 2.5 3 CW50 CW45 3765 E 33-5/16 28-1/16 6.5 12.3 2.5 3 CW50 CW45 3771 E 33-5/16 31-1/16 7.2 13.6 2.5 3 CW50 CW45 3777 E 33-5/16 34-1/16 7.9 14.9 2.5 3 CW50 CW45 3784 E 33-5/16 37-9/16 8.7 16.4 2.5 3 CW40 CW40 4135 37-5/16 13-1/16 3.4 6.5 2.5 3 CW50 CW45 4141 37-5/16 16-1/16 4.2 7.9 2.5 3 CW50 CW45 4147 37-5/16 19-1/16 4.9 9.4 2.5 3 CW50 CW45 4153 37-5/16 22-1/16 5.7 10.9 2.5 3 CW50 CW45 4157 E 37-5/16 24-1/16 6.2 11.9 2.5 3 CW50 CW45 4159 E 37-5/16 25-1/16 6.5 12.4 2.5 3 CW50 CW45 4165 E 37-5/16 28-1/16 7.3 13.8 2.5 3 CW50 CW45 4171 E 37-5/16 31-1/16 8.1 15.3 2.5 3 CW50 CW45 4177 E 37-5/16 34-1/16 8.8 16.8 2.5 3 CW45 CW45 4184 E 37-5/16 37-9/16 9.7 18.5 2.5 3 CW40 CW40 4535 41-5/16 13-1/16 3.7 7.2 2.5 3 CW50 CW45 4541 41-5/16 16-1/16 4.6 8.8 2.5 3 CW50 CW45 4547 41-5/16 19-1/16 5.5 10.5 2.5 3 CW50 CW45 4553 41-5/16 22-1/16 6.3 12.1 2.5 3 CW50 CW45 4557 E 41-5/16 24-1/16 6.9 13.2 2.5 3 CW50 CW45 4559 E 41-5/16 25-1/16 7.2 13.7 2.5 3 CW50 CW45 4565 E 41-5/16 28-1/16 8.1 15.4 2.5 3 CW50 CW45 4571 E 41-5/16 31-1/16 8.9 17.0 2.5 3 CW45 CW45 4577 E 41-5/16 34-1/16 9.8 18.7 2.5 3 CW45 CW45 4584 E 41-5/16 37-9/16 10.8 20.6 3 3 CW40 CW40 4835 44-5/16 13-1/16 4.0 7.7 2.5 3 CW50 CW45 4841 44-5/16 16-1/16 4.9 9.5 2.5 3 CW50 CW45 4847 44-5/16 19-1/16 5.9 11.3 2.5 3 CW50 CW45 4853 44-5/16 22-1/16 6.8 13.0 2.5 3 CW50 CW45 4857 E 44-5/16 24-1/16 7.4 14.2 2.5 3 CW50 CW45 4859 E 44-5/16 25-1/16 7.7 14.8 2.5 3 CW50 CW45 4865 E 44-5/16 28-1/16 8.6 16.6 2.5 3 CW45 CW45 4871 E 44-5/16 31-1/16 9.6 18.3 2.5 3 CW45 CW45 4877 E 44-5/16 34-1/16 10.5 20.1 3 3 CW45 CW45 4884 E 44-5/16 37-9/16 11.6 22.2 3 3 CW40 CW40 (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Design Data W-HG-22Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Fixed Unit Visible Glass Ft 2 Standard Glass Thickness (mm)Performance Class & Grade 1AnnealedTempered 4135 7.2 2.5 3 CW50 4141 8.6 2.5 3 CW50 4147 10.1 3 3 CW50 4153 11.6 3 3 CW50 4157 12.5 3 3 CW50 4165 14.5 3 3 CW50 4171 16.0 3 3 CW45/CW50 4735 8.4 2.5 3 CW50 4741 10.1 3 3 CW50 4747 11.8 3 3 CW50 4753 13.5 3 3 CW50 4757 14.7 3 3 CW50 4759 15.3 3 3 CW50 4765 17.0 3 3 CW45/CW50 4771 18.7 4 4 CW50 5335 9.6 2.5 3 CW45/CW50 5341 11.6 3 3 CW50 5347 13.5 3 3 CW50 5353 15.5 3 4 CW45/CW50 5357 16.8 3 4 CW45/CW50 5359 17.5 3 4 CW40/CW50 5365 19.4 4 4 CW50 5371 21.4 4 4 CW50 5935 10.8 3 3 CW50 5941 13.0 3 3 CW50 5953 17.5 3 4 CW40/CW50 5957 19.0 4 4 CW50 5959 19.7 4 4 CW50 5965 21.9 4 4 CW50 5971 24.1 4 4 CW45/CW50 Transoms Unit Visible Glass Ft 2 Standard Glass Thickness (mm)Performance Class & Grade 1AnnealedTempered 2114 0.9 2.5 3 CW50 2514 1.1 2.5 3 CW50 2914 1.3 2.5 3 CW50 3314 1.6 2.5 3 CW50 3714 1.8 2.5 3 CW50 4114 2.0 2.5 3 CW50 4514 2.2 2.5 3 CW50 4814 2.4 2.5 3 CW50 2117 1.2 2.5 3 CW50 2517 1.5 2.5 3 CW50 2917 1.8 2.5 3 CW50 3317 2.1 2.5 3 CW50 3717 2.4 2.5 3 CW50 4117 2.8 2.5 3 CW50 4517 3.1 2.5 3 CW50 4817 3.3 2.5 3 CW50 2125 2.0 2.5 3 CW50 2525 2.6 2.5 3 CW50 2925 3.1 2.5 3 CW50 3325 3.6 2.5 3 CW50 3725 4.2 2.5 3 CW50 4125 4.7 2.5 3 CW50 4525 5.2 2.5 3 CW50 4825 5.6 2.5 3 CW50 (1) Maximum design pressure when glazed with the appropriate glass thickness. Second number, where shown, requires tempered glass. Design Data W-HG-23Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Cottage Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening (Inches)Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width Height Annealed Tempered Clad Wood VG2141 17-5/16 12-11/16 1.5 3.4 2.5 3 CW50 CW45 VG2147 17-5/16 15-1/16 1.8 4.1 2.5 3 CW50 CW45 VG2153 17-5/16 17-7/16 2.1 4.7 2.5 3 CW50 CW45 VG2157 17-5/16 19-1/16 2.3 5.2 2.5 3 CW50 CW45 VG2159 17-5/16 19-7/8 2.4 5.4 2.5 3 CW50 CW45 VG2165 17-5/16 22-1/4 2.7 6.0 2.5 3 CW50 CW45 VG2171 17-5/16 24-11/16 3.0 6.6 2.5 3 CW30 CW30 VG2541 21-5/16 12-11/16 1.9 4.3 2.5 3 CW50 CW45 VG2547 21-5/16 15-1/16 2.2 5.1 2.5 3 CW50 CW45 VG2553 21-5/16 17-7/16 2.6 6.0 2.5 3 CW50 CW45 VG2557 21-5/16 19-1/16 2.8 6.5 2.5 3 CW50 CW45 VG2559 21-5/16 19-7/8 2.9 6.8 2.5 3 CW50 CW45 VG2565 21-5/16 22-1/4 3.3 7.6 2.5 3 CW50 CW45 VG2571 21-5/16 24-11/16 3.7 8.4 2.5 3 CW30 CW30 VG2941 25-5/16 12-11/16 2.2 5.2 2.5 3 CW50 CW45 VG2947 25-5/16 15-1/16 2.7 6.2 2.5 3 CW50 CW45 VG2953 25-5/16 17-7/16 3.1 7.2 2.5 3 CW50 CW45 VG2957 25-5/16 19-1/16 3.4 7.8 2.5 3 CW50 CW45 VG2959 25-5/16 19-7/8 3.5 8.2 2.5 3 CW50 CW45 VG2965 25-5/16 22-1/4 3.9 9.1 2.5 3 CW50 CW45 VG2971 25-5/16 24-11/16 4.3 10.1 2.5 3 CW30 CW30 VG3341 29-5/16 12-11/16 2.6 6.1 2.5 3 CW50 CW45 VG3347 29-5/16 15-1/16 3.1 7.3 2.5 3 CW50 CW45 VG3353 29-5/16 17-7/16 3.6 8.4 2.5 3 CW50 CW45 VG3357 29-5/16 19-1/16 3.9 9.2 2.5 3 CW50 CW45 VG3359 29-5/16 19-7/8 4.1 9.6 2.5 3 CW50 CW45 VG3365 29-5/16 22-1/4 4.5 10.7 2.5 3 CW50 CW45 VG3371 E1 29-5/16 24-11/16 5.0 11.8 2.5 3 CW30 CW30 Egress Notes: Check all applicable local codes for emergency egress requirements. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. Continued on next page Design Data Rev. 10/22/2024 W-HG-24Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. Cottage Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening (Inches)Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width Height Annealed Tempered Clad Wood VG3741 33-5/16 12-11/16 2.9 7.0 2.5 3 CW50 CW45 VG3747 33-5/16 15-1/16 3.5 8.3 2.5 3 CW50 CW45 VG3753 33-5/16 17-7/16 4.0 9.6 2.5 3 CW50 CW45 VG3757 33-5/16 19-1/16 4.4 10.5 2.5 3 CW50 CW45 VG3759 33-5/16 19-7/8 4.6 11.0 2.5 3 CW50 CW45 VG3765 33-5/16 22-1/4 5.2 12.3 2.5 3 CW50 CW45 VG3771 E 33-5/16 24-11/16 5.7 13.6 2.5 3 CW30 CW30 VG4141 37-5/16 12-11/16 3.3 7.9 2.5 3 CW50 CW45 VG4147 37-5/16 15-1/16 3.9 9.4 2.5 3 CW50 CW45 VG4153 37-5/16 17-7/16 4.5 10.9 2.5 3 CW50 CW45 VG4157 37-5/16 19-1/16 4.9 11.9 2.5 3 CW50 CW45 VG4159 37-5/16 19-7/8 5.2 12.4 2.5 3 CW50 CW45 VG4165 37-5/16 22-1/4 5.8 13.8 2.5 3 CW45 CW45 VG4171 E 37-5/16 24-11/16 6.4 15.3 2.5 3 CW30 CW30 VG4541 41-5/16 12-11/16 3.6 8.8 2.5 3 CW50 CW45 VG4547 41-5/16 15-1/16 4.3 10.5 2.5 3 CW50 CW45 VG4553 41-5/16 17-7/16 5.0 12.1 2.5 3 CW50 CW45 VG4557 41-5/16 19-1/16 5.5 13.2 2.5 3 CW45 CW45 VG4559 41-5/16 19-7/8 5.7 13.8 2.5 3 CW45 CW45 VG4565 41-5/16 22-1/4 6.4 15.4 2.5 3 CW45 CW45 VG4571 E 41-5/16 24-11/16 7.1 17.0 3 3 CW30 CW30 VG4841 44-5/16 12-11/16 3.9 9.5 2.5 3 CW50 CW45 VG4847 44-5/16 15-1/16 4.6 11.3 2.5 3 CW50 CW45 VG4853 44-5/16 17-7/16 5.4 13.0 2.5 3 CW45 CW45 VG4857 44-5/16 19-1/16 5.9 14.2 2.5 3 CW45 CW45 VG4859 44-5/16 19-7/8 6.1 14.8 2.5 3 CW45 CW45 VG4865 44-5/16 22-1/4 6.9 16.6 3 3 CW45 CW45 VG4871 E 44-5/16 24-11/16 7.6 18.3 3 3 CW30 CW30 (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Design Data Rev. 10/22/2024 W-HG-25Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Replacement Equal Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width (Inches) Height (Inches)Annealed Tempered Clad Wood 23.5 x 35.5 19-13/16 13-5/16 1.8 3.3 2.5 3 CW50 CW45 23.5 x 37.5 19-13/16 14-5/16 2.0 3.6 2.5 3 CW50 CW45 23.5 x 41.5 19-13/16 16-5/16 2.2 4.1 2.5 3 CW50 CW45 23.5 x 45.5 19-13/16 18-5/16 2.5 4.6 2.5 3 CW50 CW45 23.5 x 47.5 19-13/16 19-5/16 2.7 4.8 2.5 3 CW50 CW45 23.5 x 51.5 19-13/16 21-5/16 2.9 5.3 2.5 3 CW50 CW45 23.5 x 53.5 19-13/16 22-5/16 3.1 5.6 2.5 3 CW50 CW45 23.5 x 57.5 19-13/16 24-5/16 3.3 6.1 2.5 3 CW50 CW45 23.5 x 59.5 19-13/16 25-5/16 3.5 6.3 2.5 3 CW50 CW45 23.5 x 61.5 19-13/16 26-5/16 3.6 6.5 2.5 3 CW50 CW45 23.5 x 65.5 19-13/16 28-5/16 3.9 7.0 2.5 3 CW50 CW45 23.5 x 71.5 19-13/16 31-5/16 4.3 7.8 2.5 3 CW50 CW45 27.5 x 35.5 23-13/16 13-5/16 2.2 4.1 2.5 3 CW50 CW45 27.5 x 37.5 23-13/16 14-5/16 2.4 4.4 2.5 3 CW50 CW45 27.5 x 41.5 23-13/16 16-5/16 2.7 5.0 2.5 3 CW50 CW45 27.5 x 45.5 23-13/16 18-5/16 3.0 5.6 2.5 3 CW50 CW45 27.5 x 47.5 23-13/16 19-5/16 3.2 5.9 2.5 3 CW50 CW45 27.5 x 51.5 23-13/16 21-5/16 3.5 6.5 2.5 3 CW50 CW45 27.5 x 53.5 23-13/16 22-5/16 3.7 6.8 2.5 3 CW50 CW45 27.5 x 57.5 23-13/16 24-5/16 4.0 7.4 2.5 3 CW50 CW45 27.5 x 59.5 23-13/16 25-5/16 4.2 7.7 2.5 3 CW50 CW45 27.5 x 61.5 23-13/16 26-5/16 4.4 8.0 2.5 3 CW50 CW45 27.5 x 65.5 23-13/16 28-5/16 4.7 8.6 2.5 3 CW50 CW45 27.5 x 71.5 E1 23-13/16 31-5/16 5.2 9.5 2.5 3 CW50 CW45 29.5 x 35.5 25-13/16 13-5/16 2.4 4.4 2.5 3 CW50 CW45 29.5 x 37.5 25-13/16 14-5/16 2.6 4.8 2.5 3 CW50 CW45 29.5 x 41.5 25-13/16 16-5/16 2.9 5.4 2.5 3 CW50 CW45 29.5 x 45.5 25-13/16 18-5/16 3.3 6.1 2.5 3 CW50 CW45 29.5 x 47.5 25-13/16 19-5/16 3.5 6.4 2.5 3 CW50 CW45 29.5 x 51.5 25-13/16 21-5/16 3.8 7.1 2.5 3 CW50 CW45 29.5 x 53.5 25-13/16 22-5/16 4.0 7.4 2.5 3 CW50 CW45 29.5 x 57.5 25-13/16 24-5/16 4.4 8.1 2.5 3 CW50 CW45 29.5 x 59.5 25-13/16 25-5/16 4.5 8.4 2.5 3 CW50 CW45 29.5 x 61.5 25-13/16 26-5/16 4.7 8.7 2.5 3 CW50 CW45 29.5 x 65.5 E1 25-13/16 28-5/16 5.1 9.4 2.5 3 CW50 CW45 29.5 x 71.5 E1 25-13/16 31-5/16 5.6 10.4 2.5 3 CW50 CW45 Egress Notes: Check all applicable local codes for emergency egress requirements. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Continued on next page Design Data - Replacement Sizes W-HG-26Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. Replacement Equal Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width (Inches) Height (Inches)Annealed Tempered Clad Wood 31.5 x 35.5 27-13/16 13-5/16 2.6 4.8 2.5 3 CW50 CW45 31.5 x 37.5 27-13/16 14-5/16 2.8 5.2 2.5 3 CW50 CW45 31.5 x 41.5 27-13/16 16-5/16 3.2 5.9 2.5 3 CW50 CW45 31.5 x 45.5 27-13/16 18-5/16 3.5 6.6 2.5 3 CW50 CW45 31.5 x 47.5 27-13/16 19-5/16 3.7 7.0 2.5 3 CW50 CW45 31.5 x 51.5 27-13/16 21-5/16 4.1 7.7 2.5 3 CW50 CW45 31.5 x 53.5 27-13/16 22-5/16 4.3 8.0 2.5 3 CW50 CW45 31.5 x 57.5 27-13/16 24-5/16 4.7 8.8 2.5 3 CW50 CW45 31.5 x 59.5 27-13/16 25-5/16 4.9 9.1 2.5 3 CW50 CW45 31.5 x 61.5 E1 27-13/16 26-5/16 5.1 9.5 2.5 3 CW50 CW45 31.5 x 65.5 E1 27-13/16 28-5/16 5.5 10.2 2.5 3 CW50 CW45 31.5 x 71.5 E 27-13/16 31-5/16 6.0 11.3 2.5 3 CW50 CW45 35.5 x 35.5 31-13/16 13-5/16 2.9 5.6 2.5 3 CW50 CW45 35.5 x 37.5 31-13/16 14-5/16 3.2 6.0 2.5 3 CW50 CW45 35.5 x 41.5 31-13/16 16-5/16 3.6 6.8 2.5 3 CW50 CW45 35.5 x 45.5 31-13/16 18-5/16 4.0 7.6 2.5 3 CW50 CW45 35.5 x 47.5 31-13/16 19-5/16 4.3 8.0 2.5 3 CW50 CW45 35.5 x 51.5 31-13/16 21-5/16 4.7 8.9 2.5 3 CW50 CW45 35.5 x 53.5 31-13/16 22-5/16 4.9 9.3 2.5 3 CW50 CW45 35.5 x 57.5 E1 31-13/16 24-5/16 5.4 10.1 2.5 3 CW50 CW45 35.5 x 59.5 E1 31-13/16 25-5/16 5.6 10.5 2.5 3 CW50 CW45 35.5 x 61.5 E 31-13/16 26-5/16 5.8 10.9 2.5 3 CW50 CW45 35.5 x 65.5 E 31-13/16 28-5/16 6.3 11.8 2.5 3 CW50 CW45 35.5 x 71.5 E 31-13/16 31-5/16 6.9 13.0 2.5 3 CW50 CW45 39.5 x 35.5 35-13/16 13-5/16 3.3 6.3 2.5 3 CW50 CW45 39.5 x 37.5 35-13/16 14-5/16 3.6 6.8 2.5 3 CW50 CW45 39.5 x 41.5 35-13/16 16-5/16 4.1 7.7 2.5 3 CW50 CW45 39.5 x 45.5 35-13/16 18-5/16 4.6 8.7 2.5 3 CW50 CW45 39.5 x 47.5 35-13/16 19-5/16 4.8 9.1 2.5 3 CW50 CW45 39.5 x 51.5 35-13/16 21-5/16 5.3 10.1 2.5 3 CW50 CW45 39.5 x 53.5 35-13/16 22-5/16 5.5 10.5 2.5 3 CW50 CW45 39.5 x 57.5 E 35-13/16 24-5/16 6.0 11.5 2.5 3 CW50 CW45 39.5 x 59.5 E 35-13/16 25-5/16 6.3 11.9 2.5 3 CW50 CW45 39.5 x 61.5 E 35-13/16 26-5/16 6.5 12.4 2.5 3 CW50 CW45 39.5 x 65.5 E 35-13/16 28-5/16 7.0 13.4 2.5 3 CW50 CW45 39.5 x 71.5 E 35-13/16 31-5/16 7.8 14.8 2.5 3 CW45 CW45 41.5 x 35.5 37-13/16 13-5/16 3.5 6.7 2.5 3 CW50 CW45 41.5 x 37.5 37-13/16 14-5/16 3.8 7.2 2.5 3 CW50 CW45 41.5 x 41.5 37-13/16 16-5/16 4.3 8.2 2.5 3 CW50 CW45 41.5 x 45.5 37-13/16 18-5/16 4.8 9.2 2.5 3 CW50 CW45 41.5 x 47.5 37-13/16 19-5/16 5.1 9.7 2.5 3 CW50 CW45 41.5 x 51.5 37-13/16 21-5/16 5.6 10.7 2.5 3 CW50 CW45 41.5 x 53.5 37-13/16 22-5/16 5.9 11.2 2.5 3 CW50 CW45 41.5 x 57.5 E 37-13/16 24-5/16 6.4 12.2 2.5 3 CW50 CW45 41.5 x 59.5 E 37-13/16 25-5/16 6.6 12.7 2.5 3 CW50 CW45 41.5 x 61.5 E 37-13/16 26-5/16 6.9 13.1 2.5 3 CW50 CW45 41.5 x 65.5 E 37-13/16 28-5/16 7.4 14.1 2.5 3 CW45 CW45 41.5 x 71.5 E 37-13/16 31-5/16 8.2 15.6 2.5 3 CW45 CW45 (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Design Data - Replacement Sizes Rev. 10/22/2024 W-HG-27Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Replacement Fixed Unit Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Annealed Tempered 41 x 35.5 7.3 2.5 3 CW50 41 x 37.5 7.8 2.5 3 CW50 41 x 41.5 8.8 2.5 3 CW50 41 x 45.5 9.7 2.5 3 CW45/CW50 41 x 47.5 10.2 3.0 3 CW50 41 x 51.5 11.2 3.0 3 CW50 41 x 53.5 11.7 3.0 3 CW50 41 x 57.5 12.7 3.0 3 CW50 41 x 59.5 13.2 3.0 3 CW50 41 x 61.5 13.6 3.0 3 CW50 41 x 65.5 14.6 3.0 3 CW50 41 x 71.5 16.1 3.0 3 CW45/CW50 47 x 35.5 8.5 2.5 3 CW50 47 x 37.5 9.1 2.5 3 CW50 47 x 41.5 10.2 3.0 3 CW50 47 x 45.5 11.4 3.0 3 CW50 47 x 47.5 12.0 3.0 3 CW50 47 x 51.5 13.1 3.0 3 CW50 47 x 53.5 13.7 3.0 3 CW50 47 x 57.5 14.8 3.0 3 CW50 47 x 59.5 15.4 3.0 3 CW45/CW50 47 x 61.5 16.0 3.0 3 CW45/CW50 47 x 65.5 17.1 3.0 3 CW45/CW50 47 x 71.5 18.8 4.0 4 CW50 53 x 35.5 9.8 2.5 3 CW45/CW50 53 x 37.5 10.4 3.0 3 CW50 53 x 41.5 11.7 3.0 3 CW50 53 x 45.5 13.0 3.0 3 CW50 53 x 47.5 13.7 3.0 3 CW50 53 x 51.5 15.0 3.0 4 CW50 53 x 53.5 15.7 3.0 4 CW45/CW50 53 x 57.5 17.0 3.0 4 CW45/CW50 53 x 59.5 17.6 4.0 4 CW50 53 x 61.5 18.3 4.0 4 CW50 53 x 65.5 19.6 4.0 4 CW50 53 x 71.5 21.6 4.0 4 CW50 59 x 35.5 11.0 3.0 3 CW50 59 x 37.5 11.7 3.0 3 CW50 59 x 41.5 13.2 3.0 3 CW50 59 x 45.5 14.7 3.0 3 CW50 59 x 47.5 15.4 3.0 3 CW45/CW50 59 x 51.5 16.9 3.0 4 CW45/CW50 59 x 53.5 17.7 4.0 4 CW50 59 x 57.5 19.1 4.0 4 CW50 59 x 59.5 19.9 4.0 4 CW50 59 x 61.5 20.6 4.0 4 CW50 59 x 65.5 22.1 4.0 4 CW50 59 x 71.5 24.3 4.0 4 CW45/CW50 Replacement Transoms Unit Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Annealed Tempered 23.5 x 14 1.0 2.5 3 CW50 23.5 x 17 1.4 2.5 3 CW50 23.5 x 25 2.4 2.5 3 CW50 27.5 x 14 1.2 2.5 3 CW50 27.5 x 17 1.7 2.5 3 CW50 27.5 x 25 2.9 2.5 3 CW50 29.5 x 14 1.4 2.5 3 CW50 29.5 x 17 1.9 2.5 3 CW50 29.5 x 25 3.2 2.5 3 CW50 31.5 x 14 1.5 2.5 3 CW50 31.5 x 17 2.0 2.5 3 CW50 31.5 x 25 3.4 2.5 3 CW50 35.5 x 14 1.7 2.5 3 CW50 35.5 x 17 2.3 2.5 3 CW50 35.5 x 25 4.0 2.5 3 CW50 39.5 x 14 1.9 2.5 3 CW50 39.5 x 17 2.6 2.5 3 CW50 39.5 x 25 4.5 2.5 3 CW50 41.5 x 14 2.0 2.5 3 CW50 41.5 x 17 2.8 2.5 3 CW50 41.5 x 25 4.8 2.5 3 CW50 (1) Maximum performance when glazed with the appropriate glass thickness. Second number, where shown, requires tempered glass. Design Data - Replacement Sizes W-HG-28Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Replacement Cottage Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width (Inches) Height (Inches)Annealed Tempered Clad Wood VG23.5 x 41.5 19-13/16 12-7/8 1.8 4.1 2.5 3 CW50 CW45 VG23.5 x 45.5 19-13/16 14-1/2 2.0 4.6 2.5 3 CW50 CW45 VG23.5 x 47.5 19-13/16 15-1/4 2.1 4.8 2.5 3 CW50 CW45 VG23.5 x 51.5 19-13/16 16-7/8 2.3 5.3 2.5 3 CW50 CW45 VG23.5 x 53.5 19-13/16 17-11/16 2.4 5.6 2.5 3 CW50 CW45 VG23.5 x 57.5 19-13/16 19-1/4 2.7 6.1 2.5 3 CW50 CW45 VG23.5 x 59.5 19-13/16 19-15/16 2.8 6.3 2.5 3 CW50 CW45 VG23.5 x 61.5 19-13/16 20-7/8 2.9 6.5 2.5 3 CW50 CW45 VG23.5 x 65.5 19-13/16 22-1/2 3.1 7.0 2.5 3 CW40 CW40 VG23.5 x 71.5 19-13/16 24-7/8 3.4 7.8 2.5 3 CW30 CW30 VG27.5 x 41.5 23-13/16 12-7/8 2.1 5.0 2.5 3 CW50 CW45 VG27.5 x 45.5 23-13/16 14-1/2 2.4 5.6 2.5 3 CW50 CW45 VG27.5 x 47.5 23-13/16 15-1/4 2.5 5.9 2.5 3 CW50 CW45 VG27.5 x 51.5 23-13/16 16-7/8 2.8 6.5 2.5 3 CW50 CW45 VG27.5 x 53.5 23-13/16 17-11/16 2.9 6.8 2.5 3 CW50 CW45 VG27.5 x 57.5 23-13/16 19-1/4 3.2 7.4 2.5 3 CW50 CW45 VG27.5 x 59.5 23-13/16 19-15/16 3.3 7.7 2.5 3 CW50 CW45 VG27.5 x 61.5 23-13/16 20-7/8 3.5 8.0 2.5 3 CW50 CW45 VG27.5 x 65.5 23-13/16 22-1/2 3.7 8.6 2.5 3 CW40 CW40 VG27.5 x 71.5 23-13/16 24-7/8 4.1 9.5 2.5 3 CW30 CW30 VG29.5 x 41.5 25-13/16 12-7/8 2.3 5.4 2.5 3 CW50 CW45 VG29.5 x 45.5 25-13/16 14-1/2 2.6 6.1 2.5 3 CW50 CW45 VG29.5 x 47.5 25-13/16 15-1/4 2.7 6.4 2.5 3 CW50 CW45 VG29.5 x 51.5 25-13/16 16-7/8 3.0 7.1 2.5 3 CW50 CW45 VG29.5 x 53.5 25-13/16 17-11/16 3.2 7.4 2.5 3 CW50 CW45 VG29.5 x 57.5 25-13/16 19-1/4 3.5 8.1 2.5 3 CW50 CW45 VG29.5 x 59.5 25-13/16 19-15/16 3.6 8.4 2.5 3 CW50 CW45 VG29.5 x 61.5 25-13/16 20-7/8 3.7 8.7 2.5 3 CW50 CW45 VG29.5 x 65.5 25-13/16 22-1/2 4.0 9.4 2.5 3 CW40 CW40 VG29.5 x 71.5 25-13/16 24-7/8 4.5 10.4 2.5 3 CW30 CW30 VG31.5 x 41.5 27-13/16 12-7/8 2.5 5.9 2.5 3 CW50 CW45 VG31.5 x 45.5 27-13/16 14-1/2 2.8 6.6 2.5 3 CW50 CW45 VG31.5 x 47.5 27-13/16 15-1/4 3.0 7.0 2.5 3 CW50 CW45 VG31.5 x 51.5 27-13/16 16-7/8 3.3 7.7 2.5 3 CW50 CW45 VG31.5 x 53.5 27-13/16 17-11/16 3.4 8.0 2.5 3 CW50 CW45 VG31.5 x 57.5 27-13/16 19-1/4 3.7 8.8 2.5 3 CW50 CW45 VG31.5 x 59.5 27-13/16 19-15/16 3.9 9.1 2.5 3 CW50 CW45 VG31.5 x 61.5 27-13/16 20-7/8 4.0 9.5 2.5 3 CW50 CW45 VG31.5 x 65.5 27-13/16 22-1/2 4.3 10.2 2.5 3 CW40 CW40 VG31.5 x 71.5 27-13/16 24-7/8 4.8 11.3 2.5 3 CW30 CW30 (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Continued on next page Design Data Rev. 10/22/2024 W-HG-29Pella 2025 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional Hung Window Egress Notes: Check all applicable local codes for emergency egress requirements. E = Window meets minimum clear opening of 24" height, 20" width, and 5.7 ft 2. E1 = Window meets minimum clear opening of 24" height, 20" width, and 5.0 ft 2. Replacement Cottage Sash for Single- and Double-Hung Unit Eg r e s s Clear Opening Vent Area Ft 2 Visible Glass Ft 2 Standard Glass Thickness (mm) Performance Class & Grade 1 Width (Inches) Height (Inches)Annealed Tempered Clad Wood VG35.5 x 41.5 31-13/16 12-7/8 2.8 6.8 2.5 3 CW50 CW45 VG35.5 x 45.5 31-13/16 14-1/2 3.2 7.6 2.5 3 CW50 CW45 VG35.5 x 47.5 31-13/16 15-1/4 3.4 8.0 2.5 3 CW50 CW45 VG35.5 x 51.5 31-13/16 16-7/8 3.7 8.9 2.5 3 CW50 CW45 VG35.5 x 53.5 31-13/16 17-11/16 3.9 9.3 2.5 3 CW50 CW45 VG35.5 x 57.5 31-13/16 19-1/4 4.3 10.1 2.5 3 CW50 CW45 VG35.5 x 59.5 31-13/16 19-15/16 4.4 10.5 2.5 3 CW50 CW45 VG35.5 x 61.5 31-13/16 20-7/8 4.6 11.0 2.5 3 CW50 CW45 VG35.5 x 65.5 31-13/16 22-1/2 5.0 11.8 2.5 3 CW40 CW40 VG35.5 x 71.5 E1 31-13/16 24-7/8 5.5 13.0 2.5 3 CW30 CW30 VG39.5 x 41.5 35-13/16 12-7/8 3.2 7.7 2.5 3 CW50 CW45 VG39.5 x 45.5 35-13/16 14-1/2 3.6 8.7 2.5 3 CW50 CW45 VG39.5 x 47.5 35-13/16 15-1/4 3.8 9.1 2.5 3 CW50 CW45 VG39.5 x 51.5 35-13/16 16-7/8 4.2 10.1 2.5 3 CW50 CW45 VG39.5 x 53.5 35-13/16 17-11/16 4.4 10.5 2.5 3 CW50 CW45 VG39.5 x 57.5 35-13/16 19-1/4 4.8 11.5 2.5 3 CW50 CW45 VG39.5 x 59.5 35-13/16 19-15/16 5.0 11.9 2.5 3 CW50 CW45 VG39.5 x 61.5 35-13/16 20-7/8 5.2 12.4 2.5 3 CW45 CW45 VG39.5 x 65.5 35-13/16 22-1/2 5.6 13.4 2.5 3 CW40 CW40 VG39.5 x 71.5 E 35-13/16 24-7/8 6.2 14.8 2.5 3 CW30 CW30 VG41.5 x 41.5 37-13/16 12-7/8 3.4 8.2 2.5 3 CW50 CW45 VG41.5 x 45.5 37-13/16 14-1/2 3.8 9.2 2.5 3 CW50 CW45 VG41.5 x 47.5 37-13/16 15-1/4 4.0 9.7 2.5 3 CW50 CW45 VG41.5 x 51.5 37-13/16 16-7/8 4.4 10.7 2.5 3 CW50 CW45 VG41.5 x 53.5 37-13/16 17-11/16 4.6 11.2 2.5 3 CW50 CW45 VG41.5 x 57.5 37-13/16 19-1/4 5.1 12.2 2.5 3 CW45 CW45 VG41.5 x 59.5 37-13/16 19-15/16 5.3 12.7 2.5 3 CW45 CW45 VG41.5 x 61.5 37-13/16 20-7/8 5.5 13.2 2.5 3 CW45 CW45 VG41.5 x 65.5 37-13/16 22-1/2 5.9 14.1 2.5 3 CW40 CW40 VG41.5 x 71.5 E 37-13/16 24-7/8 6.5 15.6 2.5 3 CW30 CW30 (1) Maximum performance when glazed with the appropriate glass thickness. To convert area to square meters (m²), multiply square feet by 0.0929. Design Data Rev. 10/22/2024 ISD-1Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Product Selection Guide Size and Performance Data .........................................................................................................................................ISD-2 Sound Transmission Class and Outdoor-Indoor Transmission Class ..................................................................ISD-3 Features and Options ...................................................................................................................................................ISD-4 Combination Assemblies ........................................................................................................................................................ISD-5 Glazing Performance ...............................................................................................................................................................ISD-6 Impact-Resistant Glazing.......................................................................................................................................................ISD-11 Grille Types Typical Grille Patterns .................................................................................................................................................ISD-13 Custom Shapes ............................................................................................................................................................ISD-14 Size Tables ...............................................................................................................................................................................ISD-15 Special Sizes and Dimensions ...............................................................................................................................................ISD-21 Design Data .............................................................................................................................................................................ISD-22 Detailed Product Descriptions Clad ................................................................................................................................................................................ISD-26 Wood ..............................................................................................................................................................................ISD-27 Unit Sections Wood Collection ..........................................................................................................................................................ISD-28 Clad ................................................................................................................................................................................ISD-32 Wood ..............................................................................................................................................................................ISD-42 Handle Hardware Dimensions..................................................................................................................................ISD-46 The information published in this document is believed to be accurate at the time of publication. However, because we are constantly working to improve our products, specifications are subject to change without notice. Consult your local Pella representative for up-to-date product information. Microsoft and Microsoft Word are registered trademarks of Microsoft Corp. Supporting documents for this product: Test Reports: https://media.pella.com/professional/adm/CertificationReports/Test_Reports_PR-Clad.pdf CSI Specs (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Wood-CSI_Specs/08213-R.rtf AIA Masterspec (readable using Microsoft Word or other text editing application): https://media.pella.com/professional/adm/Wood-CSI_Specs/Masterspec/085200_fl.doc Detailed Product Description (readable using Microsoft Word or other text editing application): Clad: https://media.pella.com/professional/adm/Clad-Wood/PR-InSwingDoor-C.rtf Wood: https://media.pella.com/professional/adm/Clad-Wood/PR-InSwingDoor-W.rtf Size Tables (requires appropriate CAD software to read and use): https://media.pella.com/professional/adm/Clad-Wood/AS-IF-OG-PT-Elev_D.dwg CAD cross sections (requires appropriate CAD software to read and use): https://media.pella.com/professional/adm/Clad-Wood/PRCW-IS-Detail_D.dwg 3D & BIM / REVIT (requires appropriate software to read and use): https://media.pella.com/professional/adm/RevitFiles/PR-Revit/Door-In-Swing-Pella-Reserve-Traditional.zip Sketchup (requires appropriate software to read and use): https://media.pella.com/professional/adm/Clad-Wood/PellaSKP_PellaReserve_Traditional_Hinged_Door_In-Swing.zip Combination Recommendations: https://media.pella.com/professional/adm/Clad-Wood/D_Combinations.pdf Installation Details: https://media.pella.com/professional/adm/Clad-Wood/F_InstallationDetails.pdf Impact-Resistant In-Swing Door, Complete Product Information: https://media.pella.com/professional/adm/Clad-Wood/Pella-ImpactResistant_InSwingDoor.pdf ISD-2Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door (—) = Not Available (1) The higher the level, the greater the product’s ability to resist forced entry. Valid only if Pella supplied locking system is used. Clad Wood Sizes Standard door sizes l l Standard sidelight sizes l l Standard transom sizes — Fixed Frame Direct Set l l Fixed casement l l Wide stile casement l l Special sizes l l Custom sizes and shapes l l Standard Single-Swing Single Door Widths 2' 2" l l 2' 6" l l 2' 10" l l 3'l l 3' 2" l l Standard Single-Swing Double Door Widths 4' 2"l − 5'l − 5' 7"l − 6'l − 6' 3" l − Standard Double-Swing Door Widths 4' 2" l l 5' l l 5' 7" l l 6'l l 6' 3" l l Standard Door Heights 6' 7-1/2" l l 6' 10" l l 7' 2" l l 8' 0"l l 10' 0"l l Double-Swing Single-Swing Double Single-Swing Active/Passive Active/Fixed Active or Fixed Size and Performance Data ISD-3Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door (—) = Not Available (1) Maximum performance for single unit when glazed with the appropriate glass thickness. Doors supplied without latching hardware are not AAMA/WDMA performance certified. See Design Data pages in this section for specific product performance class and grade values. (2) The higher the level, the greater the product’s ability to resist forced entry. Valid only if Pella supplied locking system is used. (3) ASTM E 1425 defines standard sizes for acoustical testing. Ratings achieved at that size are representative of all sizes of the same configuration. NOTE: Performance with additional options may not be the same as Standard and Special size units. Please contact your local Pella representative for complete information. Clad Wood Performance data 1 Do o r s 8 ' T a l l a n d U n d e r Standard Sill - Non-Impact Glazing Meets or Exceeds AAMA / WDMA Ratings LC55 Hallmark Certified LC55 Hallmark Certified Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure)0.15 0.15 Water Resistance 8.36 psf 8.36 psf Design Pressure 55 psf 55 psf Low Profile Sill Water Resistance 0 psf 0 psf Products with Impact-Resistant Glass Meets or Exceeds AAMA / WDMA Ratings LC55 LC55 Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure)0.15 0.15 Water Resistance 8.36 psf 8.36 psf Design Pressure 55 psf 55 psf Do o r s O v e r 8 ' T a l l u p t o 1 0 ' Standard Sill - Non-Impact Glazing Meets or Exceeds AAMA / WDMA Ratings LC40 Hallmark Certified LC40 Hallmark Certified Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure)0.15 0.15 Water Resistance 7.52 psf 7.52 psf Design Pressure 40 psf 40 psf Low Profile Sill Water Resistance 0 psf 0 psf Products with Impact-Resistant Glass Meets or Exceeds AAMA / WDMA Ratings LC40 LC40 Air Infiltration (cfm / ft 2 of frame @ 1.57 psf wind pressure)0.15 0.15 Water Resistance 7.52 psf 7.52 psf Design Pressure 40 psf 40 psf Other Performance Criteria Forced Entry Resistance Level (Minimum Security Grade) 2 40 Sound Transmission Class / Outdoor-Indoor Transmission Class Product Frame Size Tested 3 Glazing System STC Rating OITC RatingOverall Glazing Thickness Exterior Glass Thickness Interior Glass Thickness Third Pane Thickness Clad In-Swing Without Grilles 71-1/4" x 81-1/2"13/16"3 mm 3 mm —31 25 71-1/4" x 81-1/2"13/16"3 mm 7.6 mm PVB —34 28 Clad In-Swing with Impact-Resistant Glass Without Grilles 71-1/4" x 81-1/2"7/8"8.6 mm PVB 4.7 mm —33 30 Size and Performance Data Rev. 12/11/23 ISD-4Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door (1) Contact your local Pella sales representative for current designs and color options. (2) ADA sill finishes available in mill or bronze anodized only. (3) Not available on Mahogany and Douglas Fir interiors. Standard Options / Upgrades Glazing Glazing Type Dual-Pane Insulating Glass Triple-Pane Insulating Glass Insulated Glass Options/Low-E Types Advanced Low-E SunDefense™ Low-E SunDefense+ Low-E AdvancedComfort Low-E NaturalSun Low-E NaturalSun+ Low-E Clear (no Low-E coating) Additional Glass Options Tempered Glass Obscure Glass 1 Tinted Glass (Bronze, Gray and Green) Impact-Resistant Laminated Glass Gas Fill/High Altitude Argon High altitude Wood Types Pine Mahogany, Douglas Fir Exterior EnduraClad® protective finish EnduraClad Plus protective finish Factory Primed Pine wood exterior Unfinished Mahogany wood exterior Cladding Colors Standard colors 1 Feature Colors, Custom Colors 1 Sill Finish 2 Black Mill finish Satin nickel anodized Bronze anodized Interior Unfinished wood Factory primed 3, Factory prefinished paint 3, Factory prefinished stain Hardware White, Champagne, Brown, Matte Black Satin Brass, Satin Nickel, Oil-Rubbed Bronze, Locking System Multi-Point — Key lock — Grilles Integral Light Technology® Grilles —Traditional, Prairie, Top Row, Cross, New England, Victorian, Custom Grilles-Between-the-Glass —Traditional, Prairie, Top Row, Cross, Custom-Equally Divided Screens —InView™ screens Features and Options Rev. 10/20/2023 ISD-5Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Combinations are a great way to create visual interest in any project. A combination is an assembly formed by two or more separate windows or doors whose frames are mulled together by a combination or reinforcing mullion. Pella window combinations are available in an endless variety of arrangements. Below are examples of common configurations, see the Combinations Recommendations document for typical mullions, requirements and limitations. Contact your local Pella sales representative for more information. (1) Other rectangular profiles are also available as combination options. Combinations ISD-6Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Glazing Performance - Total Unit (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. U-Factor values shown are based on a standard sill and pine interior. For center-glass values, see the Product Performance section. Visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent Dual-Pane Glazing - Aluminum-Clad Exterior N NC SC S CA 13/16" Clear IG PEL-N-218-07953-00001 3 3 air 0.40 0.44 0.46 48 with grilles-between-the-glass PEL-N-218-07954-00001 0.40 0.38 0.39 48 with integral grilles PEL-N-218-07955-00001 0.40 0.38 0.39 48 13/16" Advanced Low-E IG PEL-N-218-07985-00001 3 3 argon 0.27 0.21 0.39 61 SC S with grilles-between-the-glass PEL-N-218-07986-00001 0.27 0.18 0.33 61 SC S with integral grilles PEL-N-218-07987-00001 0.28 0.18 0.33 61 SC S 13/16" SunDefense™ Low-E IG PEL-N-218-07961-00001 3 3 argon 0.27 0.16 0.36 61 SC S with grilles-between-the-glass PEL-N-218-07962-00001 0.27 0.14 0.31 61 SC S with integral grilles PEL-N-218-07963-00001 0.28 0.14 0.31 61 SC S 13/16" SunDefense+ Low-E IG PEL-N-218-11573-00001 3 3 argon 0.24 0.16 0.35 48 N NC SC S with grilles-between-the-glass PEL-N-218-11574-00001 0.24 0.14 0.30 48 N NC SC S with integral grilles PEL-N-218-11575-00001 0.25 0.14 0.30 48 N NC SC S 13/16" AdvancedComfort Low-E IG PEL-N-218-07969-00001 3 3 argon 0.24 0.21 0.38 48 N NC SC S with grilles-between-the-glass PEL-N-218-07970-00001 0.24 0.18 0.33 48 N NC SC S with integral grilles PEL-N-218-07971-00001 0.25 0.18 0.33 48 N NC SC S 13/16" NaturalSun Low-E IG PEL-N-218-07977-00001 3 3 argon 0.28 0.39 0.44 60 with grilles-between-the-glass PEL-N-218-07978-00001 0.28 0.34 0.38 60 with integral grilles PEL-N-218-07979-00001 0.29 0.34 0.38 60 13/16" NaturalSun+ Low-E IG PEL-N-218-11541-00001 3 3 argon 0.25 0.36 0.43 47 N NC with grilles-between-the-glass PEL-N-218-11542-00001 0.25 0.31 0.37 47 N NC with integral grilles PEL-N-218-11543-00001 0.26 0.31 0.37 47 N NC Tinted Glazing 13/16" Bronze Advanced Low-E IG PEL-N-218-08029-00001 5 3 argon 0.27 0.19 0.25 62 SC S with grilles-between-the-glass PEL-N-218-08030-00001 0.27 0.16 0.22 62 SC S with integral grilles PEL-N-218-08031-00001 0.28 0.16 0.22 62 SC S 13/16" Gray Advanced Low-E IG PEL-N-218-08037-00001 5 3 argon 0.27 0.17 0.22 62 SC S with grilles-between-the-glass PEL-N-218-08038-00001 0.27 0.15 0.19 62 SC S with integral grilles PEL-N-218-08039-00001 0.28 0.15 0.19 62 SC S 13/16" Green Advanced Low-E IG PEL-N-218-08045-00001 5 3 argon 0.27 0.21 0.34 62 SC S with grilles-between-the-glass PEL-N-218-08046-00001 0.27 0.18 0.29 62 SC S with integral grilles PEL-N-218-08047-00001 0.28 0.18 0.29 62 SC S High Altitude Glazing 13/16" Advanced Low-E IG PEL-N-218-07981-00001 3 3 air 0.30 0.21 0.39 58 with grilles-between-the-glass PEL-N-218-07982-00001 0.30 0.19 0.33 58 with integral grilles PEL-N-218-07983-00001 0.31 0.19 0.33 58 13/16" SunDefense Low-E IG PEL-N-218-07957-00001 3 3 air 0.30 0.16 0.36 58 with grilles-between-the-glass PEL-N-218-07958-00001 0.30 0.14 0.31 58 with integral grilles PEL-N-218-07959-00001 0.30 0.14 0.31 58 13/16" SunDefense+ Low-E IG PEL-N-218-11569-00001 3 3 air 0.26 0.16 0.35 45 N NC SC S with grilles-between-the-glass PEL-N-218-11570-00001 0.26 0.14 0.30 45 N NC SC S with integral grilles PEL-N-218-11571-00001 0.27 0.14 0.30 45 SC S 13/16" AdvancedComfort Low-E IG PEL-N-218-07965-00001 3 3 air 0.26 0.21 0.38 45 N NC SC S with grilles-between-the-glass PEL-N-218-07966-00001 0.26 0.18 0.33 45 N NC SC S with integral grilles PEL-N-218-07967-00001 0.27 0.18 0.33 45 SC S 13/16" NaturalSun Low-E IG PEL-N-218-07973-00001 3 3 air 0.30 0.39 0.44 57 with grilles-between-the-glass PEL-N-218-07974-00001 0.30 0.34 0.38 57 with integral grilles PEL-N-218-07975-00001 0.31 0.34 0.38 57 13/16" NaturalSun+ Low-E IG PEL-N-218-11537-00001 3 3 air 0.26 0.35 0.43 44 N NC with grilles-between-the-glass PEL-N-218-11538-00001 0.26 0.31 0.37 44 N NC with integral grilles PEL-N-218-11539-00001 0.27 0.31 0.37 44 Climate Zones CA Rev. 02/26/2024 ISD-7Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Glazing Performance - Total Unit (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. U-Factor values shown are based on a standard sill and pine interior. For center-glass values, see the Product Performance section. Visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Mid.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent Triple-Pane Glazing - Aluminum-Clad Exterior N NC SC S CA 1" Advanced Low-E IG PEL-N-218-08345-00001 3 3 3 argon 0.22 0.19 0.35 70 N NC SC S with grilles-between-the-glass PEL-N-218-08346-00001 0.23 0.17 0.29 70 N NC SC S with integral grilles PEL-N-218-08347-00001 0.23 0.17 0.29 70 N NC SC S 1" SunDefense™ Low-E IG PEL-N-218-08357-00001 3 3 3 argon 0.22 0.15 0.32 70 N NC SC S with grilles-between-the-glass PEL-N-218-08358-00001 0.23 0.13 0.27 70 N NC SC S with integral grilles PEL-N-218-08359-00001 0.23 0.13 0.27 70 N NC SC S 1" NaturalSun Low-E IG PEL-N-218-08333-00001 3 3 3 argon 0.23 0.32 0.39 70 N NC with grilles-between-the-glass PEL-N-218-08334-00001 0.23 0.28 0.33 70 N NC with integral grilles PEL-N-218-08335-00001 0.23 0.28 0.33 70 N NC High Altitude Glazing 1" Advanced Low-E IG PEL-N-218-08341-00001 3 3 3 air 0.25 0.19 0.35 66 N NC SC S with grilles-between-the-glass PEL-N-218-08342-00001 0.26 0.17 0.29 66 N NC SC S with integral grilles PEL-N-218-08343-00001 0.25 0.17 0.29 66 N NC SC S 1" SunDefense Low-E IG PEL-N-218-08353-00001 3 3 3 air 0.25 0.15 0.32 66 N NC SC S with grilles-between-the-glass PEL-N-218-08354-00001 0.26 0.13 0.27 66 N NC SC S with integral grilles PEL-N-218-08355-00001 0.25 0.13 0.27 66 N NC SC S 1" NaturalSun Low-E IG PEL-N-218-08329-00001 3 3 3 air 0.25 0.32 0.39 66 N NC with grilles-between-the-glass PEL-N-218-08330-00001 0.26 0.28 0.33 66 N NC with integral grilles PEL-N-218-08331-00001 0.26 0.28 0.33 66 N NC Climate Zones CA Rev. 02/26/2024 ISD-8Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Glazing Performance - Total Unit Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent Dual-Pane Glazing - Wood Exterior N NC SC S CA 13/16" Clear IG PEL-N-215-06521-00001 3 3 Air 0.39 0.44 0.46 46 with grilles-between-the-glass PEL-N-215-06522-00001 0.39 0.38 0.39 46 with integral grilles PEL-N-215-06523-00001 0.40 0.38 0.39 46 13/16" Advanced Low-E IG PEL-N-215-06537-00001 3 3 Argon 0.27 0.21 0.39 59 SC S with grilles-between-the-glass PEL-N-215-06538-00001 0.27 0.18 0.33 59 SC S with integral grilles PEL-N-215-06539-00001 0.28 0.18 0.33 59 SC S 13/16" SunDefense™ Low-E IG PEL-N-215-06529-00001 3 3 Argon 0.27 0.16 0.36 46 SC S with grilles-between-the-glass PEL-N-215-06530-00001 0.27 0.14 0.31 46 SC S with integral grilles PEL-N-215-06531-00001 0.27 0.14 0.31 46 SC S 13/16" SunDefense+ Low-E IG PEL-N-215-08533-00001 3 3 argon 0.24 0.16 0.35 39 N NC SC S with grilles-between-the-glass PEL-N-215-08534-00001 0.24 0.14 0.30 39 N NC SC S with integral grilles PEL-N-215-08535-00001 0.25 0.14 0.30 39 N NC SC S 13/16" AdvancedComfort Low-E IG PEL-N-215-06553-00001 3 3 Argon 0.24 0.21 0.38 58 N NC SC S with grilles-between-the-glass PEL-N-215-06554-00001 0.24 0.18 0.33 58 N NC SC S with integral grilles PEL-N-215-06555-00001 0.25 0.18 0.33 58 N NC SC S 13/16" NaturalSun Low-E IG PEL-N-215-06545-00001 3 3 Argon 0.28 0.39 0.44 59 with grilles-between-the-glass PEL-N-215-06546-00001 0.28 0.34 0.38 59 with integral grilles PEL-N-215-06547-00001 0.28 0.34 0.38 59 13/16" NaturalSun+ Low-E IG PEL-N-215-08509-00001 3 3 argon 0.24 0.36 0.43 49 N NC with grilles-between-the-glass PEL-N-215-08510-00001 0.24 0.31 0.37 49 N NC with integral grilles PEL-N-215-08511-00001 0.25 0.31 0.37 49 N NC Tinted Glazing 13/16" Bronze Advanced Low-E IG PEL-N-215-06573-00002 5 3 Argon 0.27 0.19 0.25 58 SC S with grilles-between-the-glass PEL-N-215-06574-00002 0.27 0.17 0.22 62 SC S with integral grilles PEL-N-215-06575-00002 0.28 0.17 0.22 58 SC S 13/16" Gray Advanced Low-E IG PEL-N-215-06573-00003 5 3 Argon 0.27 0.17 0.22 58 SC S with grilles-between-the-glass PEL-N-215-06574-00003 0.27 0.15 0.19 62 SC S with integral grilles PEL-N-215-06575-00003 0.28 0.15 0.19 58 SC S 13/16" Green Advanced Low-E IG PEL-N-215-06573-00004 5 3 Argon 0.27 0.21 0.34 58 SC S with grilles-between-the-glass PEL-N-215-06574-00004 0.27 0.19 0.29 62 SC S with integral grilles PEL-N-215-06575-00004 0.28 0.19 0.29 58 SC S High Altitude Glazing 13/16" Advanced Low-E IG PEL-N-215-06533-00001 3 3 Air 0.30 0.21 0.39 46 with grilles-between-the-glass PEL-N-215-06534-00001 0.30 0.19 0.33 46 with integral grilles PEL-N-215-06535-00001 0.30 0.19 0.33 46 13/16" SunDefense Low-E IG PEL-N-215-06525-00001 3 3 Air 0.29 0.16 0.36 46 with grilles-between-the-glass PEL-N-215-06526-00001 0.29 0.14 0.31 46 with integral grilles PEL-N-215-06527-00001 0.30 0.14 0.31 46 13/16" SunDefense+ Low-E IG PEL-N-215-08529-00001 3 3 air 0.25 0.16 0.35 49 N NC SC S with grilles-between-the-glass PEL-N-215-08530-00001 0.25 0.14 0.30 49 N NC SC S with integral grilles PEL-N-215-08531-00001 0.26 0.14 0.30 52 N NC SC S 13/16" AdvancedComfort Low-E IG PEL-N-215-06549-00001 3 3 Air 0.26 0.21 0.38 62 N NC SC S with grilles-between-the-glass PEL-N-215-06550-00001 0.26 0.18 0.33 62 N NC SC S with integral grilles PEL-N-215-06551-00001 0.26 0.18 0.33 62 N NC SC S 13/16" NaturalSun Low-E IG PEL-N-215-06541-00001 3 3 Air 0.30 0.39 0.44 63 with grilles-between-the-glass PEL-N-215-06542-00001 0.30 0.34 0.38 63 with integral grilles PEL-N-215-06543-00001 0.31 0.34 0.38 63 13/16" NaturalSun+ Low-E IG PEL-N-215-08505-00001 3 3 air 0.26 0.36 0.43 41 N NC with grilles-between-the-glass PEL-N-215-08506-00001 0.26 0.31 0.37 41 N NC with integral grilles PEL-N-215-08507-00001 0.27 0.31 0.37 41 (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. U-Factor values shown are based on a standard sill and pine interior. For center-glass values, see the Product Performance section. Visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor, SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission, CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones CA Rev. 04/02/2024 ISD-9Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Glazing Performance - Total Unit Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Mid.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent Triple-Pane Glazing - Wood Exterior N NC SC S CA 1" Advanced Low-E IG PEL-N-215-06713-00001 3 3 3 Argon 0.22 0.19 0.35 64 N NC SC S with grilles-between-the-glass PEL-N-215-06714-00001 0.23 0.17 0.29 64 N NC SC S with integral grilles PEL-N-215-06715-00001 0.23 0.17 0.29 64 N NC SC S 1" SunDefense™ Low-E IG PEL-N-215-06725-00001 3 3 3 Argon 0.22 0.15 0.32 68 N NC SC S with grilles-between-the-glass PEL-N-215-06726-00001 0.23 0.13 0.27 68 N NC SC S with integral grilles PEL-N-215-06727-00001 0.22 0.13 0.27 68 N NC SC S 1" NaturalSun Low-E IG PEL-N-215-06701-00001 3 3 3 Argon 0.22 0.32 0.39 67 N NC with grilles-between-the-glass PEL-N-215-06702-00001 0.23 0.28 0.33 67 N NC with integral grilles PEL-N-215-06703-00001 0.23 0.28 0.33 67 N NC High Altitude Glazing 1" Advanced Low-E IG PEL-N-215-06709-00001 3 3 3 Air 0.25 0.20 0.35 68 N NC SC S with grilles-between-the-glass PEL-N-215-06710-00001 0.25 0.17 0.29 68 N NC SC S with integral grilles PEL-N-215-06711-00001 0.25 0.17 0.29 68 N NC SC S 1" SunDefense Low-E IG PEL-N-215-06721-00001 3 3 3 Air 0.25 0.15 0.32 69 N NC SC S with grilles-between-the-glass PEL-N-215-06722-00001 0.25 0.13 0.27 69 N NC SC S with integral grilles PEL-N-215-06723-00001 0.25 0.13 0.27 69 N NC SC S 1" NaturalSun Low-E IG PEL-N-215-06697-00001 3 3 3 Air 0.25 0.32 0.39 69 N NC with grilles-between-the-glass PEL-N-215-06698-00001 0.25 0.28 0.33 69 N NC with integral grilles PEL-N-215-06699-00001 0.25 0.28 0.33 69 N NC (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. U-Factor values shown are based on a standard sill and pine interior. For center-glass values, see the Product Performance section. Visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones CA Rev. 10/20/2023 ISD-10Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Glazing Performance - Total Unit (1) Glazing performance values are calculated for Pine using NFRC 100, NFRC 200 and NFRC 500. Thermal performance of other wood species may vary. ENERGY STAR® values are updated to 2023 (Version 7) criteria. (2) The values shown are based on Canada's updated ENERGY STAR® 2020 initiative. U-Factor values shown are based on a standard sill and pine interior. For center-glass values, see the Product Performance section. Visit www.energystar.gov for Energy Star guidelines. R-Value = 1/U-Factor SHGC = Solar Heat Gain Coefficient VLT % = Visible Light Transmission CR = Condensation Resistance ER = Canadian Energy Rating Climate Zones CA Gl a z i n g Th i c k n e s s Type of Glazing NFRC Certified Product # Glass (mm) Gap Fill Performance Values 1 Shaded Areas Meet ENERGY STAR® Performance Criteria in Zones Shown Ext.Int. U- F a c t o r SH G C VL T CR U. S.Canada 2 Zone ER Zone Vent - Laminated Impact-Resistant Glass N NC SC S CA 7/8"Clear IG PEL-N-218-08281-00001 8 5 air 0.41 0.38 0.44 43 with grilles-between-the-glass PEL-N-218-08282-00001 0.42 0.33 0.38 43 with integral grilles PEL-N-218-08283-00001 0.42 0.33 0.38 43 7/8"Advanced Low-E IG PEL-N-218-08285-00001 8 5 argon 0.29 0.21 0.38 58 with grilles-between-the-glass PEL-N-218-08286-00001 0.30 0.18 0.33 58 with integral grilles PEL-N-218-08287-00001 0.30 0.18 0.33 58 7/8"SunDefense™ Low-E IG PEL-N-218-08289-00001 8 5 argon 0.28 0.17 0.35 58 SC S with grilles-between-the-glass PEL-N-218-08290-00001 0.30 0.15 0.30 58 with integral grilles PEL-N-218-08291-00001 0.30 0.15 0.30 58 Tinted Laminated Impact-Resistant Glass 7/8"Bronze Advanced Low-E IG PEL-N-218-08293-00001 8 5 air 0.41 0.26 0.18 44 with grilles-between-the-glass PEL-N-218-08294-00001 0.42 0.23 0.15 44 with integral grilles PEL-N-218-08295-00001 0.41 0.23 0.15 44 7/8"Gray Advanced Low-E IG PEL-N-218-08297-00001 8 5 air 0.41 0.29 0.21 44 with grilles-between-the-glass PEL-N-218-08298-00001 0.42 0.25 0.18 44 with integral grilles PEL-N-218-08299-00001 0.41 0.25 0.18 44 7/8"Green Advanced Low-E IG PEL-N-218-08301-00001 8 5 air 0.41 0.34 0.36 44 with grilles-between-the-glass PEL-N-218-08302-00001 0.42 0.30 0.31 44 with integral grilles PEL-N-218-08303-00001 0.41 0.30 0.31 44 Rev. 02/26/2024 ISD-11Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door (—) = Not applicable. (1) Units are tested for air/water/structural and impact-resistance, and certified for wind zone 4, large missile rating D. For clear opening, vent area, visible glass, and frame area, see clad Design Data pages. To convert areas to square meters (m2), multiply square feet by 0.0929. Doors with low profile sills, curved glass in rectangular panel, custom stiles and rails, and no-lock no-bore hardware options are not certified to above standards. Clad 7/8" Insulated Glass PVB Maximum Performance Grade 1 Vent units 6' 10" tall and under +55 / -70 Vent units 8' 0" tall and under +55 / -70 Vent units over 8' 0" tall up to 10' 0" tall +40 / -40 Fixed units 6' 10" tall and under +55 / -70 Fixed units 8' 0" tall and under +55 / -70 Fixed units over 8' 0" tall up to 10' 0" tall +55 / -70 Certification Miami-Dade County — Hallmark 411-H-1164 FPAS FL14293 TDI DR-635 Impact-Resistant Glass For a complete list of ratings, refer to the Impact-Resistant product section. [2 0 6 ] 8 1 / 8 " [4 6 ] 1 1 3 / 1 6 " [52] 2 1/16" [5 2 ] 2 1 / 1 6 " [1 2 8 ] 5" Installation Fin Optional Fold-out [31] 1 1/4" [38] 1 1/2" [110] 4 5/16" FRAME WIDTH [148] 5 13/16" [1 4 9 ] 5 7 / 8 " [119] 4 11/16" [2 0 ] 13 / 1 6 " [1 1 9 ] 4 1 1 / 1 6 " [2 0 6 ] 8 1 / 8 " FR A M E H E I G H T [25] 1" [3 3 ] 1 5 / 1 6 " [1 1 6 ] 4 9 / 1 6 " [3 8 ] 1 1 / 2 " [2 5 ] 1" [149] 5 7/8" [9 4 4 ] 3' - 1 3 / 1 6 " VENT VS VH HJLJ LOCK JAMBLJ HINGE JAMBHJ VS VENT SILL VH VENT HEAD ISD-12Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Interior wood Integral Light Technology grilles available in Pine, Mahogany or Douglas Fir to match complete unit. 3/4" 2" Regular1 1/4" Regular7/8" Regular 2" Regular 2" 2" 5/8" Regular 1 1/4" Regular7/8" Regular5/8" Regular 1 1/4" Regular7/8" Regular 3/4" Wood Exterior - Wood Interior Putty Glaze and Ogee Grilles 7/8" 5/8"1 1/4"7/8" 5/8"1 1/4" Clad Exterior - Wood Interior Putty Glaze and Ogee Grilles 7/8" 5/8"1 1/4"7/8" 5/8"1 1/4" Grilles-Between-the-Glass ®Traditional Style Collection - Integral Light Technology Clad Exterior - Wood Interior Ogee Grilles 7/8"1 1/4" 2" 2" 1 1/4"7/8" Contoured 3/4" Contoured 3/4" Grille Profiles ISD-13Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Grilles-Between-the-Glass Prairie Lite Patterns Other Available Patterns VG = Visible Glass Lite dimensions noted can vary. Custom configurations are available; for details contact your local Pella sales representative. For traditional patterns, see size tables. Other Available Patterns Integral Light Technology® Grilles Prairie Lite Patterns * Grille Patterns All sidelights and transoms will have 9 lights. Standard corner lite dimension for Prairie patterns = 3-1/2" VG. Integral Light Technology Grilles • 9-Lite available in all standard and special sizes. • 12-Lite available at 8' height; other heights available per custom drawing. • 14-Lite available in units > 2' 1-1/2" width. Top Row • Standard visible glass to separator bar = 14" or half of total visible glass height, whichever is smaller. Cross • Standard visible glass to separator bar = one-quarter of total visible glass height. New England • Standard visible glass to separator bar = half of total visible glass height. Prairie • Standard corner lite dimension = 3-1/2" VG. • 9-Lite available in units < 7' 0-3/4" height. • * Prairie in heights > 7' 0-1/2" will have 12 lites. • 12-Lite available in units ≤ 7' 2" height. Cross • Horizontal bar is 1/4 of visible glass from the top in door panels. • Not available in transoms. Top Row • Horizontal bar may be ordered 12", 14" or 16" from the top VG. • Transoms with frame heights ≥ 21", the horizontal bar will be positioned at 1/2 the visible glass height. • Top Row not available in transoms with frame height <21". * ISD-14Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Pella Reserve In-Swing French doors are available in the additional shapes shown below, as well as custom shapes. For specifications, size limitations, and details on these units, contact your local Pella sales representative. Left Right Left Right Custom Shapes ISD-15Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Not to scale. Traditional grille patterns shown. Refer to Clad/Wood Overview section for additional patterns and profiles. All doors and sidelights are glazed with tempered glass. Left-hand single doors shown, right-hand and fixed also available. For Wood Units Only: To determine masonry dimensions when using Pella 1-7/8" brickmould, add 1-5/8" to frame height and 3-1/8" to frame width. When using Pella 3-1/2" brickmould, add 6-3/8" to frame width and 3-1/4" to frame height. 7580 FIXED-ACTIVE 7580 ACTIVE-PASSIVE 7280 ACTIVE-PASSIVE 6780 ACTIVE-PASSIVE 6080 ACTIVE-PASSIVE 5080 ACTIVE-PASSIVE 5080 FIXED-ACTIVE 6080 FIXED-ACTIVE 6780 FIXED-ACTIVE 7280 FIXED-ACTIVE 3880 LEFT 3680 LEFT 3480 LEFT 3080 LEFT 2680 LEFT 1880 SIDELIGHT (1 905) (1 924) 4"3 / 6' 3" 6' 3 (1 905) (1 924) 4"3 / 6' 3" 6' 3 6' 7" Double Doors Fixed-Active Frame Opening Frame Opening " / 2 1 (2 0 1 9 ) (2 0 3 2 ) 6' 7 6' 8 " " / 2 1 (2 0 1 9 ) (2 0 3 2 ) 6' 7 6' 8 " "/83 (1 702) (1 682)(1 270) (1 289) (1 810) (1 829) (1 505) (1 524) Frame /"41/"41 4"3 / /"41 5' 7" 5' 64' 2" 4' 2 5' 11 6' 0" 4' 11 5' 0" Opening /"41/"41 4"3 / /"41 6' 7" Double Doors Active-Passive 6' 7" Single Doors and Sidelight "/21 "/7 8 "8/5/"41"1/8 4"3 /4"3 /4"3 / " / 2 1 (645) (664) 2' 2 2' 1 1' 6 1' 6" (933) (914) (476) (457) 3' 0 3' 0" (762) (781) 2' 6 2' 6" (870) 2' 10 2' 9 (851) 3' 1 3' 2 (962) (981) 5' 7" 5' 6 (1 702) (1 682) 4' 2" 4' 2 (1 270) (1 289) (1 810) (1 829) 5' 11 6' 0" (1 505) (1 524) 4' 11 5' 0" (2 0 1 9 ) (2 0 3 2 ) 6' 7 6' 8 " Size Tables ISD-16Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Not to scale. Traditional grille patterns shown. Refer to Clad/Wood Overview section for additional patterns and profiles. All doors and sidelights are glazed with tempered glass. Left-hand single doors shown, right-hand and fixed also available. For Wood Units Only: To determine masonry dimensions when using Pella 1-7/8" brickmould, add 1-5/8" to frame height and 3-1/8" to frame width. When using Pella 3-1/2" brickmould, add 6-3/8" to frame width and 3-1/4" to frame height. 7582 FIXED-ACTIVE 7582 ACTIVE-PASSIVE 7282 ACTIVE-PASSIVE 6782 ACTIVE-PASSIVE 6082 ACTIVE-PASSIVE 5082 ACTIVE-PASSIVE 7282 FIXED-ACTIVE 6782 FIXED-ACTIVE 6082 FIXED-ACTIVE 5082 FIXED-ACTIVE 3682 LEFT 3482 LEFT 3082 LEFT 2682 LEFT 1882 SIDELIGHT 3882 LEFT (1 905) (1 924) 4"3 / 6' 3" 6' 3 (1 905) (1 924) 4"3 / 6' 3" 6' 3 6' 10" Double Doors Active-Passive 6' 10" Single Doors and Sidelight 6' 10" Double-Swing Doors Fixed-Active " / 2 1 6' 9 6' 1 0 " (2 0 7 0 ) (2 0 8 3 ) " / 2 1 6' 9 6' 1 0 " (2 0 7 0 ) (2 0 8 3 ) Frame Opening Frame Opening "/83 (1 702) (1 682)(1 270) (1 289) (1 810) (1 829) (1 505) (1 524) Frame /"41/"41 4"3 / /"41 5' 7" 5' 64' 2" 4' 2 5' 11 6' 0" 4' 11 5' 0" Opening /"41/"41 4"3 / /"41 "/21 "/7 8 "8/5/"41"1/8 4"3 /4"3 /4"3 / (645) (664) 2' 2 2' 1 1' 6 1' 6" (933) (914) (476) (457) 3' 0 3' 0" (762) (781) 2' 6 2' 6" (870) 2' 10 2' 9 (851) 3' 1 3' 2 (962) (981) 5' 7" 5' 6 (1 702) (1 682) 4' 2" 4' 2 (1 270) (1 289) (1 810) (1 829) 5' 11 6' 0" (1 505) (1 524) 4' 11 5' 0" " / 2 1 6' 9 6' 1 0 " (2 0 7 0 ) (2 0 8 3 ) Size Tables ISD-17Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door 7586 FIXED-ACTIVE 7586 ACTIVE-PASSIVE 5086 ACTIVE-PASSIVE 6086 ACTIVE-PASSIVE 6786 ACTIVE-PASSIVE 7286 ACTIVE-PASSIVE 5086 FIXED-ACTIVE 6086 FIXED-ACTIVE 6786 FIXED-ACTIVE 7286 FIXED-ACTIVE 3886 LEFT 3686 LEFT 3486 LEFT 3086 LEFT 2686 LEFT 1886 SIDELIGHT (1 905) (1 924) 4"3 / 6' 3" 6' 3 (1 905) (1 924) 4"3 / 6' 3" 6' 3 7' 2" Double Doors Active-Passive 7' 2" Single Doors and Sidelight 7' 2" Double-Swing Doors Fixed-Active " / 2 1 7' 2 " (2 1 8 4 ) 7' 2 (2 1 9 7 ) " / 2 1 7' 2 " (2 1 8 4 ) 7' 2 (2 1 9 7 ) Frame Opening Frame Opening "/83 (1 702) (1 682)(1 270) (1 289) (1 810) (1 829) (1 505) (1 524) Frame /"41/"41 4"3 / /"41 5' 7" 5' 64' 2" 4' 2 5' 11 6' 0" 4' 11 5' 0" Opening /"41/"41 4"3 / /"41 "/21 "/7 8 "8/5/"41"1/8 4"3 /4"3 /4"3 / (645) (664) 2' 2 2' 1 1' 6 1' 6" (933) (914) (476) (457) 3' 0 3' 0" (762) (781) 2' 6 2' 6" (870) 2' 10 2' 9 (851) 3' 1 3' 2 (962) (981) 5' 7" 5' 6 (1 702) (1 682) 4' 2" 4' 2 (1 270) (1 289) (1 810) (1 829) 5' 11 6' 0" (1 505) (1 524) 4' 11 5' 0" " / 2 1 7' 2 " (2 1 8 4 ) 7' 2 (2 1 9 7 ) Not to scale. Traditional grille patterns shown. Refer to Clad/Wood Overview section for additional patterns and profiles. All doors and sidelights are glazed with tempered glass. Left-hand single doors shown, right-hand and fixed also available. For Wood Units Only: To determine masonry dimensions when using Pella 1-7/8" brickmould, add 1-5/8" to frame height and 3-1/8" to frame width. When using Pella 3-1/2" brickmould, add 6-3/8" to frame width and 3-1/4" to frame height. Size Tables ISD-18Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door 7596 FIXED-ACTIVE 7596 ACTIVE-PASSIVE 5096 ACTIVE-PASSIVE 6096 ACTIVE-PASSIVE 6796 ACTIVE-PASSIVE 7296 ACTIVE-PASSIVE 5096 FIXED-ACTIVE 6096 FIXED-ACTIVE 6796 FIXED-ACTIVE 7296 FIXED-ACTIVE 3896 LEFT 3696 LEFT 3496 LEFT 3096 LEFT 2696 LEFT 1896 SIDELIGHT (1 905) (1 924) 4"3 / 6' 3" 6' 3 (1 905) (1 924) 4"3 / 6' 3" 6' 3 8' 0" Double Doors Active-Passive 8' 0" Double-Swing Doors Fixed-Active 8' 0" Single Doors and Sidelight " / 2 1 7' 1 1 8' 0 " (2 4 2 6 ) (2 4 3 8 ) " / 2 1 7' 1 1 8' 0 " (2 4 2 6 ) (2 4 3 8 ) Frame Opening Frame Opening "/83 (1 702) (1 682)(1 270) (1 289) (1 810) (1 829) (1 505) (1 524) Frame /"41/"41 4"3 / /"41 5' 7" 5' 64' 2" 4' 2 5' 11 6' 0" 4' 11 5' 0" Opening /"41/"41 4"3 / /"41 "/21 "/7 8 "8/5/"41"1/8 4"3 /4"3 /4"3 / (645) (664) 2' 2 2' 1 1' 6 1' 6" (933) (914) (476) (457) 3' 0 3' 0" (762) (781) 2' 6 2' 6" (870) 2' 10 2' 9 (851) 3' 1 3' 2 (962) (981) 5' 7" 5' 6 (1 702) (1 682) 4' 2" 4' 2 (1 270) (1 289) (1 810) (1 829) 5' 11 6' 0" (1 505) (1 524) 4' 11 5' 0" " / 2 1 7' 1 1 8' 0 " (2 4 2 6 ) (2 4 3 8 ) Not to scale. Traditional grille patterns shown. Refer to Clad/Wood Overview section for additional patterns and profiles. All doors and sidelights are glazed with tempered glass. Left-hand single doors shown, right-hand and fixed also available. For Wood Units Only: To determine masonry dimensions when using Pella 1-7/8" brickmould, add 1-5/8" to frame height and 3-1/8" to frame width. When using Pella 3-1/2" brickmould, add 6-3/8" to frame width and 3-1/4" to frame height. Size Tables ISD-19Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door 38120 LEFT 36120 LEFT 34120 LEFT 30120 LEFT 26120 LEFT 50120 ACTIVE-PASSIVE 60120 ACTIVE-PASSIVE 67120 ACTIVE-PASSIVE 72120 ACTIVE-PASSIVE 75120 ACTIVE-PASSIVE (1 905) (1 924) 4"3 / 6' 3" 6' 3 " / 2 1 9' 1 1 10 ' 0 " (3 0 3 5 ) (3 0 4 8 ) 10' 0" Double Doors Active-Passive Frame Opening /"41/"41 4"3 / /"41 5' 7" 5' 6 (1 702) (1 682) 4' 2" 4' 2 (1 270) (1 289) (1 810) (1 829) 5' 11 6' 0" (1 505) (1 524) 4' 11 5' 0" 10' 0" Single Doors and Sidelight "/83Frame Opening "/21 "/7 8 "8/5/"41"1/8 4"3 /4"3 / (645) (664) 2' 2 2' 1 (933) (914) 3' 0 3' 0" (762) (781) 2' 6 2' 6" (870) 2' 10 2' 9 (851) 3' 1 3' 2 (962) (981) " / 2 1 9' 1 1 10 ' 0 " (3 0 3 5 ) (3 0 4 8 ) Not to scale. Traditional grille patterns shown. Refer to Clad/Wood Overview section for additional patterns and profiles. All doors and sidelights are glazed with tempered glass. Left-hand single doors shown, right-hand and fixed also available. For Wood Units Only: To determine masonry dimensions when using Pella 1-7/8" brickmould, add 1-5/8" to frame height and 3-1/8" to frame width. When using Pella 3-1/2" brickmould, add 6-3/8" to frame width and 3-1/4" to frame height. Size Tables ISD-20Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door 5014 6014 6714 7214 7225672560255025 5017 6017 6717 7217 3425 3417 3414 2625 2617 2614 3814 3817 382536253025 3017 3617 36143014 3425 3417 3414 2625 2617 2614 3814 3817 382536253025 3017 3617 36143014 3425 3417 3414 2625 2617 2614 3814 3817 382536253025 3017 3617 36143014 5014 6014 6714 7214 5014 6014 6714 7214 7225672560255025 5017 6017 6717 7217 7217671760175017 5025 6025 6725 7225 (4 3 2 ) (4 5 1 ) (4 3 2 ) (4 5 1 ) Fixed Frame Direct Sets for Double Doors GBG Only 4" 3 / (6 3 5 ) (6 5 4 ) 2' 1 " 2' 1 4" 3 / 1' 5 " 1' 5 4" 3 / (3 5 6 ) (3 7 5 ) 1' 2 " 1' 2 Fixed Frame Direct Sets for Single Doors GBG Only 4"3 / /"41 /"41 /"41 5' 0" 4' 11 (1 524) (1 505) 6' 0" 5' 11 (1 829) (1 810)(1 289)(1 270) 4' 2 4' 2" (1 682) (1 702) 5' 6 5' 7" 4" 3 / (6 3 5 ) (6 5 4 ) 2' 1 " 2' 1 4" 3 / 1' 5 " 1' 5 4" 3 / (3 5 6 ) (3 7 5 ) 1' 2 " 1' 2 4" 3 / (6 3 5 ) (6 5 4 ) 2' 1 " 2' 1 4" 3 / (4 3 2 ) (4 5 1 ) 1' 5 " 1' 5 4" 3 / "/83 (3 5 6 ) (3 7 5 ) 1' 2 " 1' 2 "8/5 "/7 8 4"3 /4"3 //"41"1/8 "/21 (645) (664) Opening 2' 2 Frame 2' 1 (933) (914) 3' 0 3' 0" (762) (781) 2' 6 2' 6" (870) 2' 10 2' 9 (851) 3' 1 3' 2 (962) (981) Standard Stile Transoms for Double DoorsStandard Stile Transoms for Single Doors Wide Stile Transoms for Single Doors Wide Stile Transoms for Double-Swing Doors T T T T T T T T T T Not to scale. T Tempered glass is standard. Traditional grille patterns shown. Refer to Clad/Wood Overview section for additional patterns and profiles. For Wood Units Only: To determine masonry dimensions when using Pella 1-7/8" brickmould, add 1-5/8" to frame height and 3-1/8" to frame width. When using Pella 3-1/2" brickmould, add 6-3/8" to frame width and 3-1/4" to frame height. Size Tables ISD-21Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door FW = Frame Width, FH = Frame Height (1) Available within size range shown. (2) Rectangular Units Only Keep frame dimensions to the nearest 1/8" increment. To convert areas to square meters (m²), multiply square feet by 0.0929. Special Size Frame Dimensions 1 Door Type Standard Doors Products with Impact-Resistant Glass 2 Frame Width Frame Height Frame Width Frame Height Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum Transoms 25-3/8"75"14"25"25-3/8"75"14"25" (645)(1 905)(356)(635)(645)(1 905)(356)(635) Sidelight (Fixed) 18"65"36"119-1/2"12"42"48"96" (457)(457)(914)(3 035)(305)(1 067)(1 219)(2 438) Single Doors 18"48"36"119-1/2"24"37-7/8"76-3/8"119-1/2" (457)(1 219)(914)(3 035)(610)(962)(1 940)(3 035) Double Doors (AP-PA) 36"96"36"119-1/2"48"75"73-3/8"119-1/2" (914)(2 438)(914)(3 035)(1 219)(1 905)(1 864)(3 035) Double Doors (AF-FA) 50"75"79-1/2"119-1/2"48"75"73-3/8"119-1/2" (1 270)(1 905)(2 019)(3 035)(1 219)(1 905)(1 864)(3 035) Hinged Door Screen Availability 2 Door Type Frame Width Frame Height Minimum Maximum Minimum Maximum Single Door 24" 42"71-1/4"98-1/8" (610)(1 067)(1 810)(2 492) Double Door 48"84"71-1/4"98-1/8" (1 219)(2 134)(1 810)(2 492) Miscellaneous Formulas Visible Glass Actual Glass Width Height Width Height Transoms — Fixed Frame Direct Set FW - 3-1/4"FH - 3-1/4"FW - 2"FH - 2" Transoms — Fixed Casement FW - 5-3/4" FH - 5-3/4" FW - 4-3/8" FH - 4-3/8"Transoms — Wide Stile Casement FW - 11-5/8"FW - 10-1/4" Sidelights FW - 6-5/8" FH - 15-3/4" FW - 5-5/8" FH - 4-3/8"Single Doors FW - 11-5/8"FW - 10-5/8" Double Doors FW - 11-5/8"(FW ÷ 2) - 10-1/4" Clad and Wood Width Height Clear Opening (@ 90º) Single Door FW - 5-5/16" FH - 3-1/16"Double Doors (Active/Single Panel)(FW ÷ 2) - 5" Double Doors (Both Panels)FW - 7-1/2" Clear Opening (@ 172º) Single Door FW - 3-3/16" FH - 3-1/16"Double Doors (Active/Single Panel) (FW ÷ 2) - 2-13/16" Double Doors (Both Panels)FW - 3" @ 90° Width CLEAR OPENING WIDTH 172° Width vent area of door. Shaded portion shows HE I G H T CL E A R O P E N I N G Clear Opening Schematic Special Sizes and Dimensions ISD-22Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door In-Swing French Design Data Unit Single and Double Doors Clear Opening (Inches) 1 Ve n t A r e a (S t a n d a r d S i l l ) Ve n t A r e a (A D A S i l l ) Visible Glass Ft2 Standard Glass Thickness (mm) Tempered Pe r f o r m a n c e Cl a s s & G r a d e 2 Width (Inches) (172°) Width (Inches) (90°) Standard Sill Unit Height ADA Sill Unit Height Dual-Pane Glazing Triple-Pane Glazing 6' 7 - 1 / 2 " D O O R S 2680 F ——————6.1 3 3 LC55 3080 F ——————8.1 3 3 LC55 3480 F ——————9.7 3 3 LC55 3680 F ——————10.8 3 3 LC55 3880 F ——————11.6 3 3 LC55 2680 L / R 22-5/16 20-1/16 76-7/16 77-1/2 11.8 12.0 6.1 3 3 LC55 3080 L / R 26-15/16 24-11/16 76-7/16 77-1/2 14.3 14.5 8.1 3 3 LC55 3480 L / R 30-7/16 28-3/16 76-7/16 77-1/2 16.2 16.4 9.7 3 3 LC55 3680 L / R 32-15/16 30-11/16 76-7/16 77-1/2 17.5 17.7 10.8 3 3 LC55 3880 L / R 34-13/16 32-9/16 76-7/16 77-1/2 18.5 18.7 11.6 3 3 LC55 5080 FA/AF 22-5/16 20-1/16 76-7/16 77-1/2 11.8 12.0 12.2 3 3 LC55 6080 FA/AF 26-15/16 24-11/16 76-7/16 77-1/2 14.3 14.5 16.3 3 3 LC55 6780 FA/AF 30-7/16 28-3/16 76-7/16 77-1/2 16.2 16.4 19.4 3 3 LC55 7280 FA/AF 32-15/16 30-11/16 76-7/16 77-1/2 17.5 17.7 21.6 3 3 LC55 7580 FA/AF 34-13/16 32-9/16 76-7/16 77-1/2 18.5 18.7 23.2 3 3 LC55 5080 PA / AP 47/ 22-1/4 42-1/2/ 20 76-7/16 77-1/2 25.0 25.3 12.2 3 3 LC55 6080 PA / AP 56-1/4/ 26-7/8 51-3/4 / 24-5/8 76-7/16 77-1/2 29.9 30.3 16.3 3 3 LC55 6780 PA / AP 63-1/4/ 30-7/8 58-3/4/ 28-5/8 76-7/16 77-1/2 33.6 34.0 19.4 3 3 LC55 7280 PA / AP 68-1/4/ 32-7/8 63-3/4 / 30-5/8 76-7/16 77-1/2 36.2 36.7 21.6 3 3 LC55 7580 PA / AP 72 / 34-3/4 67-1/2 / 32-1/2 76-7/16 77-1/2 38.2 38.8 23.2 3 3 LC55 (—) = Not Applicable (1) All dimensions are approximate to the nearest 1/16". The second value, where shown, provides the clear opening for the active panel only. (2) Maximum performance when glazed with the appropriate glass thickness. All doors and sidelights are Tempered glass. To convert areas to square meters (m²), multiply square feet by 0.0929. Design Data ISD-23Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door In-Swing French Design Data Unit Single and Double Doors Clear Opening (Inches) 1 Ve n t A r e a (S t a n d a r d S i l l ) Ve n t A r e a (A D A S i l l ) Visible Glass Ft2 Standard Glass Thickness (mm) Tempered Pe r f o r m a n c e Cl a s s & G r a d e 2 Width (Inches) (172°) Width (Inches) (90°) Standard Sill Unit Height ADA Sill Unit Height Dual-Pane Glazing Triple-Pane Glazing 6' 1 0 " D O O R S 2682 F ——————6.3 3 3 LC55 3082 F ——————8.4 3 3 LC55 3482 F ——————9.8 3 3 LC55 3682 F ——————11.1 3 3 LC55 3882 F ——————12.0 3 3 LC55 2682 L / R 22-5/16 20-1/16 78-7/16 79-1/2 12.2 12.3 6.3 3 3 LC55 3082 L / R 26-15/16 24-11/16 78-7/16 79-1/2 14.7 14.9 8.4 3 3 LC55 3482 L / R 30-7/16 28-3/16 78-7/16 79-1/2 16.6 16.8 9.8 3 3 LC55 3682 L / R 32-15/16 30-11/16 78-7/16 79-1/2 17.9 18.2 11.1 3 3 LC55 3882 L / R 34-13/16 32-9/16 78-7/16 79-1/2 19.0 19.2 12.0 3 3 LC55 5082 FA / AF 22-5/16 20-1/16 78-7/16 79-1/2 12.2 12.3 12.6 3 3 LC55 6082 FA / AF 26-15/16 24-11/16 78-7/16 79-1/2 14.7 14.9 16.8 3 3 LC55 6782 FA / AF 30-7/16 28-3/16 78-7/16 79-1/2 16.6 16.8 19.6 3 3 LC55 7282 FA / AF 32-15/16 30-11/16 78-7/16 79-1/2 17.9 18.2 22.3 3 3 LC55 7582 FA / AF 34-13/16 32-9/16 78-7/16 79-1/2 19.0 19.2 24.0 3 3 LC55 5082 PA / AP 47/ 22-1/4 42-1/2/ 20 78-7/16 79-1/2 25.6 26.0 12.6 3 3 LC55 6082 PA / AP 56-1/4/ 26-7/8 51-3/4 / 24-5/8 78-7/16 79-1/2 30.6 31.1 16.8 3 3 LC55 6782 PA / AP 63-1/4/ 30-7/8 58-3/4/ 28-5/8 78-7/16 79-1/2 34.5 34.9 19.6 3 3 LC55 7282 PA / AP 68-1/4/ 32-7/8 63-3/4 / 30-5/8 78-7/16 79-1/2 37.2 37.7 22.3 3 3 LC55 7582 PA / AP 72 / 34-3/4 67-1/2 / 32-1/2 78-7/16 79-1/2 39.2 39.8 24.0 3 3 LC55 7' 2 " D O O R S 2686 F ——————6.7 3 3 LC55 3086 F ——————9.0 3 3 LC55 3486 F ——————10.7 3 3 LC55 3686 F ——————11.9 3 3 LC55 3886 F ——————12.8 3 3 LC55 2686 L / R 22-5/16 20-1/16 82-15/16 84 12.9 13.0 6.7 3 3 LC55 3086 L / R 26-15/16 24-11/16 82-15/16 84 15.5 15.7 9.0 3 3 LC55 3486 L / R 30-7/16 28-3/16 82-15/16 84 17.5 17.8 10.7 3 3 LC55 3686 L / R 32-15/16 30-11/16 82-15/16 84 19.0 19.2 11.9 3 3 LC55 3886 L / R 34-13/16 32-9/16 82-15/16 84 20.1 20.3 12.8 3 3 LC55 5086 FA / AF 22-5/16 20-1/16 82-15/16 84 12.9 13.0 13.4 3 3 LC55 6086 FA / AF 26-15/16 24-11/16 82-15/16 84 15.5 15.7 17.9 3 3 LC55 6786 FA / AF 30-7/16 28-3/16 82-15/16 84 17.5 17.8 21.3 3 3 LC55 7286 FA / AF 32-15/16 30-11/16 82-15/16 84 19.0 19.2 23.8 3 3 LC55 7586 FA / AF 34-13/16 32-9/16 82-15/16 84 20.1 20.3 25.6 3 3 LC55 5086 PA / AP 47/ 22-1/4 42-1/2/ 20 82-15/16 84 27.1 27.4 13.4 3 3 LC55 6086 PA / AP 56-1/4/ 26-7/8 51-3/4 / 24-5/8 82-15/16 84 32.4 32.8 17.9 3 3 LC55 6786 PA / AP 63-1/4/ 30-7/8 58-3/4/ 28-5/8 82-15/16 84 36.4 36.9 21.3 3 3 LC55 7286 PA / AP 68-1/4/ 32-7/8 63-3/4 / 30-5/8 82-15/16 84 39.3 39.8 23.8 3 3 LC55 7586 PA / AP 72 / 34-3/4 67-1/2 / 32-1/2 82-15/16 84 41.5 42.0 25.6 3 LC55 (—) = Not Applicable (1) All dimensions are approximate to the nearest 1/16". The second value, where shown, provides the clear opening for the active panel only. (2) Maximum performance when glazed with the appropriate glass thickness. All doors and sidelights are Tempered glass. To convert areas to square meters (m²), multiply square feet by 0.0929. Design Data ISD-24Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door In-Swing French Design Data Unit Single and Double Doors Clear Opening (Inches) 1 Ve n t A r e a (S t a n d a r d S i l l ) Ve n t A r e a (A D A S i l l ) Visible Glass Ft2 Standard Glass Thickness (mm) Tempered Pe r f o r m a n c e Cl a s s & G r a d e 2 Width (Inches) (172°) Width (Inches) (90°) Standard Sill Unit Height ADA Sill Unit Height Dual-Pane Glazing Triple-Pane Glazing 8' 0 " D O O R S 2696 F ——————7.6 3 3 LC55 3096 F ——————10.2 3 3 LC55 3496 F ——————12.1 3 3 LC55 3696 F ——————13.5 3 3 LC55 3896 F ——————14.5 3 3 LC55 2696 L / R 22-5/16 20-1/16 92-7/16 93-1/2 14.3 14.5 7.6 3 3 LC55 3096 L / R 26-15/16 24-11/16 92-7/16 93-1/2 17.3 17.5 10.2 3 3 LC55 3496 L / R 30-7/16 28-3/16 92-7/16 93-1/2 19.5 19.8 12.1 3 3 LC55 3696 L / R 32-15/16 30-11/16 92-7/16 93-1/2 21.1 21.4 13.5 3 3 LC55 3896 L / R 34-13/16 32-9/16 92-7/16 93-1/2 22.4 22.6 14.5 3 3 LC55 5096 FA / AF 22-5/16 20-1/16 92-7/16 93-1/2 14.3 14.5 15.2 3 3 LC55 6096 FA / AF 26-15/16 24-11/16 92-7/16 93-1/2 17.3 17.5 20.4 3 3 LC55 6796 FA / AF 30-7/16 28-3/16 92-7/16 93-1/2 19.5 19.8 24.2 3 3 LC55 7296 FA / AF 32-15/16 30-11/16 92-7/16 93-1/2 21.1 21.4 27.0 3 3 LC55 7596 FA / AF 34-13/16 32-9/16 92-7/16 93-1/2 22.4 22.6 29.1 3 3 LC55 5096 PA / AP 47/ 22-1/4 42-1/2/ 20 92-7/16 93-1/2 30.2 30.5 15.2 3 3 LC55 6096 PA / AP 56-1/4/ 26-7/8 51-3/4 / 24-5/8 92-7/16 93-1/2 36.1 36.5 20.4 3 3 LC55 6796 PA / AP 63-1/4/ 30-7/8 58-3/4/ 28-5/8 92-7/16 93-1/2 40.6 41.1 24.2 3 3 LC55 7296 PA / AP 68-1/4/ 32-7/8 63-3/4 / 30-5/8 92-7/16 93-1/2 43.8 44.3 27.0 3 3 LC55 7596 PA / AP 72 / 34-3/4 67-1/2 / 32-1/2 92-7/16 93-1/2 46.2 46.8 29.1 3 3 LC55 10 ' 0 " D O O R S 26120 F ——————9.9 5 —LC55 30120 F ——————13.2 5 —LC55 34120 F ——————15.8 5 —LC55 36120 F ——————17.6 5 —LC55 38120 F ——————18.9 5 —LC55 26120 L/R 22-5/16 20-1/16 116-7/16 117-1/2 18.0 18.2 9.9 5 —LC40 30120 L/R 26-15/16 24-11/16 116-7/16 117-1/2 21.8 22.0 13.2 5 —LC40 34120 L/R 30-7/16 28-3/16 116-7/16 117-1/2 24.6 24.8 15.8 5 —LC40 36120 L/R 32-15/16 30-11/16 116-7/16 117-1/2 26.6 26.9 17.6 5 —LC40 38120 L/R 34-13/16 32-9/16 116-7/16 117-1/2 28.2 28.4 18.9 5 —LC40 50120 PA/AP 47/ 22-1/4 42-1/2/ 20 116-7/16 117-1/2 38.0 38.4 19.8 5 —LC40 60120 PA/AP 56-1/4/ 26-7/8 51-3/4 / 24-5/8 116-7/16 117-1/2 45.5 45.9 26.5 5 —LC40 67120 PA/AP 63-1/4/ 30-7/8 58-3/4/ 28-5/8 116-7/16 117-1/2 51.1 51.6 31.5 5 —LC40 72120 PA/AP 68-1/4/ 32-7/8 63-3/4 / 30-5/8 116-7/16 117-1/2 55.2 55.7 35.1 5 —LC40 75120 PA/AP 72 / 34-3/4 67-1/2 / 32-1/2 116-7/16 117-1/2 58.2 58.8 37.8 5 —LC40 (—) = Not Applicable (1) All dimensions are approximate to the nearest 1/16". The second value, where shown, provides the clear opening for the active panel only. (2) Maximum performance when glazed with the appropriate glass thickness. All doors and sidelights are Tempered glass. To convert areas to square meters (m²), multiply square feet by 0.0929. Sidelights Unit Visible Glass Ft2 Standard Glass Thickness (mm) Tempered Performance Class & Grade Dual-Pane Glazing Triple-Pane Glazing 1880 5 3 3 LC55 1881 5.1 3 3 LC55 1882 5.2 3 3 LC55 1886 5.5 3 3 LC55 1896 6.3 3 3 LC55 Design Data ISD-25Pella 2024 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.Pella.com Pella® Reserve™ Traditional In-Swing Patio Door Transoms Unit Vi s i b l e Gl a s s F t 2 Standard Glass Thickness (mm) Pe r f o r m a n c e Cl a s s & Gr a d e 2 Dual-Pane Glazing Triple-Pane Glazing Annealed Tempered Annealed or Tempered TR A N S O M S — F I X E D F R A M E D I R E C T S E T 2614 1.7 3 3 3 CW50 2617 2.1 3 3 3 CW50 2625 3.3 3 3 3 CW50 3014 2.0 3 3 3 CW50 3017 2.6 3 3 3 CW50 3025 4.0 3 3 3 CW50 3414 2.3 3 3 3 CW50 3417 2.9 3 3 3 CW50 3425 4.6 3 3 3 CW50 3614 2.4 3 3 3 CW50 3617 3.1 3 3 3 CW50 3625 4.9 3 3 3 CW50 3814 2.6 3 3 3 CW50 3817 3.3 3 3 3 CW50 3825 5.2 3 3 3 CW50 5014 3.5 3 3 3 CW50 5017 4.5 3 3 3 CW50 5025 7.1 3 3 3 CW50 6014 4.2 3 3 3 CW50 6017 5.3 3 3 3 CW50 6025 8.5 3 3 3 CW50 6714 4.7 3 3 3 CW40 6717 6.0 3 3 3 CW40 6725 9.5 3 3 3 CW40 7214T 5.1 —3 3 CW40 7217 6.5 3 3 3 CW40 7225 10.3 3 3 3 CW40 7514T 5.4 —3 3 CW40 7517T 6.8 —3 3 CW40 7525 10.8 3 3 3 CW40 TR A N S O M S — S T A N D A R D S T I L E 2614 1.1 2.5 3 3 CW50 2617 1.5 2.5 3 3 CW50 2625 2.6 2.5 3 3 CW50 3014 1.4 2.5 3 3 CW50 3017 1.9 2.5 3 3 CW50 3025 3.2 2.5 3 3 CW50 3414 1.6 2.5 3 3 CW50 3417 2.2 2.5 3 3 CW50 3425 3.7 2.5 3 3 CW50 3614 1.7 2.5 3 3 CW50 3617 2.4 2.5 3 3 CW50 3625 4.0 2.5 3 3 CW50 3814 1.8 2.5 3 3 CW50 3817 2.5 2.5 3 3 CW50 3825 4.3 2.5 3 3 CW50 5014 2.5 2.5 3 3 CW50 5017 3.5 2.5 3 3 CW50 5025 5.9 2.5 3 3 CW50 6014T 3.1 —3 3 CW50 6017 4.2 2.5 3 3 CW50 6025 7.2 2.5 3 3 CW45/CW50 6714T 3.5 —3 3 R151 6717 4.7 2.5 3 3 R151 6725 8.1 2.5 3 3 R151 7214T 3.8 —3 3 R151 7217T 5.1 —3 3 R151 7225 8.8 2.5 3 3 R151 7514T 4.0 —3 3 R151 7517T 5.4 —3 3 R151 7525 9.3 2.5 3 3 R151 Transoms Unit Vi s i b l e Gl a s s F t 2 Standard Glass Thickness (mm) Pe r f o r m a n c e Cl a s s & Gr a d e 2 Dual-Pane Glazing Triple-Pane Glazing Annealed Tempered Annealed or Tempered TR A N S O M S — W I D E S T I L E 2614 0.8 2.5 3 3 R151 2617 1.1 2.5 3 3 R151 2625 1.8 2.5 3 3 R151 3014 1.1 2.5 3 3 R151 3017 1.4 2.5 3 3 R151 3025 2.5 2.5 3 3 R151 3414 1.3 2.5 3 3 R151 3417 1.7 2.5 3 3 R151 3425 2.9 2.5 3 3 R151 3614 1.4 2.5 3 3 R151 3617 1.9 2.5 3 3 R151 3625 3.3 2.5 3 3 R151 3814 1.5 2.5 3 3 R151 3817 2.1 2.5 3 3 R151 3825 3.5 2.5 3 3 R151 5014 2.2 2.5 3 3 R151 5017 3.0 2.5 3 3 R151 5025 5.1 2.5 3 3 R151 6014T 2.7 —3 3 R151 6017 3.7 2.5 3 3 R151 6025 6.4 2.5 3 3 R151 6714T 3.1 —3 3 R151 6717T 4.3 —3 3 R151 6725 7.3 2.5 3 3 R151 7214T 3.4 —3 3 R151 7217T 4.7 —3 3 R151 7225 8.0 2.5 3 3 R151 7514T 3.6 —3 3 R151 7517T 5.0 —3 3 R151 7525 8.5 2.5 3 3 R151 (—) = Not Applicable T = Tempered required due to aspect ratio. (1) Units are not AAMA/WDMA performance certified. Units are engineered to meet the performance class and grade shown. (2) Maximum performance when glazed with the appropriate glass thickness. Design Data Sure-Weld® Mechanically Fastened and Adhered Roofing Systems TABLE OF CONTENTS July 2025 Part I – General 1.01 Description ............................................................................................................................................................................................ 3 1.02 General Design Considerations ............................................................................................................................................................. 4 1.03 Quality Assurance ................................................................................................................................................................................... 5 1.04 Submittals ............................................................................................................................................................................................... 6 1.05 Warranty ................................................................................................................................................................................................. 7 TABLE I – Warranty Options and Minimum Membrane Thickness ......................................................................................................................... 9 TABLE II – Mechanically Fastened TPO – Membrane Fastening – Steel/Concrete Decks .................................................................................. 10 TABLE III – Mechanically Fastened TPO – Membrane Fastening – Plywood or OSB Decks .............................................................................. 11 TABLE IV – Mechanically Fastened TPO – Membrane Fastening – Lightweight/Gypsum/Wood Fiber Decks .................................................... 12 TABLE V – Adhered TPO – Underlayment/Fastening – Up to 20 Yr Warranties ................................................................................................. 13 TABLE VI – Adhered TPO SAT – Underlayment/Fastening – Up to 20 Yr Warranties ........................................................................................ 15 TABLE VII – Adhered TPO – Underlayment/Fastening – 25/30 Yr Warranties .................................................................................................... 17 TABLE VIII – Adhered TPO SAT – Underlayment/Fastening – 25/30 Yr Warranties ........................................................................................... 18 TABLE IX - Minimum Perimeter Width For Insulation Attachment For All Warranties Up to 30 YR .................................................................... 19 1.06 Job Conditions ...................................................................................................................................................................................... 20 1.07 Product Delivery Storage and Handling ................................................................................................................................................ 20 Part II – Product 2.01 General ................................................................................................................................................................................................. 21 2.02 Membranes ........................................................................................................................................................................................... 21 2.03 Insulations/Underlayments.................................................................................................................................................................... 24 2.04 Related Materials .................................................................................................................................................................................. 30 2.05 Fastening Components ......................................................................................................................................................................... 32 2.06 Insulation Securement Adhesive .......................................................................................................................................................... 34 2.07 Vapor/ Air Barrier .................................................................................................................................................................................. 34 2.08 Edgings/Terminations ........................................................................................................................................................................... 36 2.09 Roof Walkways ..................................................................................................................................................................................... 38 2.10 Other Carlisle Accessories.................................................................................................................................................................... 38 Part III – Execution 3.01 General ................................................................................................................................................................................................. 39 3.02 Roof Deck/Substrate Criteria ................................................................................................................................................................ 39 3.03 Insulation/Underlayment ....................................................................................................................................................................... 41 3.04 Insulation Attachment ........................................................................................................................................................................... 42 3.05 Membrane Placement and Securement Criteria ................................................................................................................................... 44 3.06 Heat Welding Procedures ..................................................................................................................................................................... 48 3.07 Welding Problems/Repairs ................................................................................................................................................................... 50 3.08 Flashings ............................................................................................................................................................................................... 50 3.09 Roof Walkways ..................................................................................................................................................................................... 53 3.10 Daily Seal .............................................................................................................................................................................................. 53 ATTACHMENTS Attachment I – Induction Welding Attachment Method ......................................................................................................................................... 55 Attachment II – TPO Flashing Procedures utilizing Sure-White EPDM Flashing Products .................................................................................. 71 Attachment III – Sure-Weld TPO (16’ Wide) Mechanically Fastened Roofing Systems Utilizing Standard Mechanical Fasteners and Induction Welding (RhinoBond \ Isoweld Attachment Method .............................................................................................................................................. 87 Installation Details ................................................................................................................................................................................................. 99 Note: In addition to the information listed in this section Specifiers and Authorized applicators should reference Spec Supplement and Design Reference Sections for other pertinent information. SURE-WELD TPO 07/2025 2 SURE-WELD TPO 07/2025 3 Sure Weld Mechanically Fastened and Adhered Roofing Systems July 2025 The information contained in this generic specification represents a part of Carlisle’s requirements for obtaining a roofing system warranty. Construction materials and practices, building siting and operation, climatic conditions, and other site-specific factors will have an impact on the performance of the roofing system. Carlisle recommends that the building owner retain a design professional to determine appropriate design measures to be taken in order to address these factors. This section is to serve as criteria for Specifiers and Authorized Applicators regarding the design and installation of Carlisle's Adhered and Mechanically Fastened TPO Membrane Roofing Systems. Additional information essential for the design and installation of the roof system mentioned herein are also included in the Design Reference Section and also listed in the form of a Specification Supplement at the end of the Technical Manual. Specifiers and Authorized Applicators are advised to reference all applicable sections. Various Warranty Tables have been included in Paragraph 1.05 citing various requirements by which specific warranty coverage can be obtained. Appropriate Warranty Table should be referenced to ensure proper warranty coverage. Part I – GENERAL 1.01 Description A. Mechanically Fastened Systems (Sure-Weld) 1. The Sure-Weld Mechanically Fastened Roofing System incorporates 12', 10' or 8' wide, white, tan or gray in 45, 60 or 80-mil thick scrim-reinforced, Sure-Weld Thermoplastic Polyolefin (TPO) membrane field sheets (also available in special colors in 60-mil thick, maximum 10’ wide sheets). The Spectro-Weld™ Mechanically Fastened Roofing System incorporates 10’ or 6’ wide, white, 60 or 80-mil thick scrim-reinforced Thermoplastic Polyolefin (TPO) membrane field sheets. Insulation is mechanically fastened to an acceptable roof deck. Sure-Weld perimeter sheets (6' used with 10' and 12' wide field sheets; 4' used with 8' wide field sheets) are installed along building edges and field membrane sheets are mechanically fastened to the roof deck with the appropriate Carlisle fasteners and fastening plates. Adjoining sheets of Sure-Weld membrane are overlapped and joined together with a minimum 1-1/2" wide heat weld. Membrane fastening requirements are outlined in Warranty Tables in Paragraph 1.05 of this Specification. NOTE: The Sure-Weld Mechanically Fastened Roofing System may be specified using over an existing standing seam, flat seam or corrugated metal roof (mechanically fastened systems incorporate membrane securement into the structural purlins). Refer to the Metal Retrofit Roofing System Specification, published separately, for applicable requirements. B. Adhered Roofing Systems (Sure-Weld / Sure-Weld SAT™) 1. The Sure-Weld Adhered Roofing System incorporates maximum 16' wide white, gray or tan 45, 60 or 80-mil thick scrim-reinforced Sure-Weld Thermoplastic Polyolefin (TPO) membrane and special colors in 60-mil thick, 5’ and 10’ wide sheets). The Spectro-Weld™ Adhered Roofing System incorporates 10’ wide, white, 60 or 80- mil thick scrim-reinforced Thermoplastic Polyolefin (TPO) membrane field sheets. Carlisle Insulation is mechanically fastened to the roof deck or secured with Flexible FAST™ Adhesive, OlyBond 500 BA, or OlyBond Spot Shot Adhesive and the membrane is fully adhered to the insulation with the appropriate Sure- Weld Bonding Adhesive. Adjoining sheets of membrane are overlapped approximately 2" and joined together with a minimum 1-1/2" wide heat weld. SURE-WELD TPO 07/2025 4 2. The Sure-Weld SAT™ (Self Adhering Technology) membrane is a heat-weldable single-ply thermoplastic polyolefin (TPO) sheet available in 10’ and 12’ wide, (white, tan or gray) 60 or 80-mil thick reinforced TPO membrane laminated to an elastomeric pressure-sensitive adhesive. 1.02 General Design Considerations Various Warranty Tables have been included in Paragraph 1.05 citing various requirements by which specific warranty coverage can be obtained. Appropriate Warranty Table should be referenced to ensure proper warranty coverage. A. The maximum roof slope for Mechanically Fastened Roofing Systems is 18" in one horizontal foot. There are no maximum slope restrictions for the application of the Adhered Roofing System. B. The mechanically fastened roofing system is not acceptable for installations on steel decks lighter than 22 gauge unless the steel deck is used in conjunction with lightweight concrete and a minimum of 360 pounds pullout per fastener is achieved with HP-X Fasteners into the steel deck below. An Adhered Roofing System may be specified or refer to the Metal Retrofit Roofing System Specification, published separately for other roofing options. C. Certain petroleum based products, chemicals, and waste products may not be compatible with this roofing system. Contact Carlisle for verification of compatibility and recommendations concerning an acceptable roofing assembly. D. Metal-Edge Systems and Copings should be designed in compliance with Section 1504.5 of the International Building Code and shall be tested in accordance with ANSI/SPRI ES-1. E. Concentrated loads from rooftop equipment may cause deformation of insulation/underlayment and possible damage to the membrane if proper protection is not provided. A protection course or sleepers must be specified. F. It is the responsibility of the specifier to review local, state and regional codes to determine their impact on the specified Carlisle Roofing System. G. It is the responsibility of the building owner or his/her designated representative to verify structural load limitation. In addition, a core cut may be taken to verify weight of existing components when the roofing system is to be specified on an existing facility. H. For information regarding CRRC (Cool Roof Rating Council) and LEED™, refer to the applicable Product Data Sheets and Design Reference DR 07 “CRRC/LEED Information”. I. Construction Generated Moisture / Vapor Drive 1. On new construction projects, especially in cold climate regions, moisture generated due to the construction process could adversely impact various components within the roofing assembly if not addressed. Refer to Design Reference DR-01 ”Construction Generated Moisture” included in the Carlisle Technical Manual. 2. On structural concrete decks, when a vapor retarder is not used, gaps in the deck along the perimeter and around penetrations must be sealed along with vertical joints between tilt-up panels, if present, to prevent infiltration of hot humid air and possible moisture contamination resulting from condensation. This is specifically important when adhesive is used to attach the roof insulation. NOTE: If left unaddressed, collected moisture could weaken insulation boards and facers resulting in a blow-off or increase the probability of mold growth. J. Drainage 1. Drainage must be evaluated by the specifier in accordance with all applicable codes. Slopes may be provided by tapering the structure or through the use of tapered insulation; a sufficient number of roof drains should also be specified and properly located to allow for positive drainage. Significant ponding that could remain after 48 hours should be eliminated with the addition of auxiliary drains in low areas where ponding is anticipated. Carlisle specifically disclaims responsibility for the design and selection of an adequate drainage system and drain accessories. Selection must be made by the building owner or the owner's design professional. 2. Small incidental areas of ponded water will not impact the performance of this roofing system; however, in accordance with industry standards, the roofing assembly should be designed to prevent ponding of water SURE-WELD TPO 07/2025 5 on the roof for prolonged periods (longer than 48 hours). Good roofing practice dictates proper drainage to prevent possible excessive live load and, in the event of a roof leak, to minimize potential interior damage to the roofing assembly and to the interior of the building. 3. Tapered edge strips, crickets or saddles are recommended where periodic ponding of water may occur. When the slope of the taper exceeds 2 inches to one horizontal foot, additional membrane securement at the base of the tapered edge strip will be required. 4. Subject to code requirement, it is recommended that a minimum roof slope of 1/8" per horizontal foot be provided to serve long-term aesthetics. On New Construction projects, roof drains should be positioned in areas where maximum deflection is anticipated. Slopes greater than 1/8” per foot should be considered due to possible roof deflection. K. Vapor Retarders 1. Carlisle does not require a vapor retarder for the protection of the membrane; however, it should be considered by the specifier for the protection of the roofing assembly (i.e. primarily insulation, underlayment and adhesives). The following criteria should be considered by the specifier: 2. Use of a vapor retarder to protect insulation and reduce moisture accumulation within an insulated roofing assembly, should be investigated by the specifier. 3. In the generally temperate climate of the United States, during the winter months, water vapor flows upward from a heated, more humid interior toward a colder, drier exterior. Vapor retarders are more commonly required in northern climates than in southern regions, where downward vapor pressure may be expected and the roofing membrane itself becomes the vapor retarder. 4. All Carlisle roofing membranes are tested and pass in accordance with ASTM E 2178 and shall qualify as an air barrier when following Carlisle specifications and details for roofing applications. L. Retrofit - Recover Projects (when the existing roofing material is left in place) 1. The removal of existing wet insulation and membrane must be specified. The specifier shall select an appropriate and compatible material as filler for voids created by removal of old insulation or membrane. 2. Entrapment of water between old and new membrane can damage and deteriorate new insulation/underlayment between the two membranes. If a vapor retarder or air barrier is not specified, Carlisle recommends existing membrane be perforated to avoid potential moisture accumulation to allow for detection of moisture to enable the building owner to take corrective action. This can be accomplished by drilling approximately 3/4" diameter holes every 100 square feet in the existing built-up roof or single-ply membrane (excluding non-reinforced PVC membrane). 3. If total removal of existing non-reinforced PVC membrane is not specified, existing membrane may be cut into maximum 10' x 10' sections, when the new insulation or membrane underlayment is to be mechanically fastened. 4. Regardless of the type of membrane or assembly selected, any loose flashings at the perimeter, roof drains and roof penetrations must be removed. 1.03 Quality Assurance Building codes are above and beyond the intended purpose of this specification. The building owner, owner’s representative or Specifier should verify local codes for applicable requirements and limitations. It is the responsibility of the specifier to review local, state and regional codes to determine their impact on the specified Carlisle Roofing System. NOTE: For code approvals achieved with the Carlisle Roofing Systems, refer to the Carlisle Code Approval Guide, DORA (Directory of Roof Assemblies), Factory Mutual (FM) Approval Guide or Underwriters Laboratories (UL) Fire Resistance or Roofing Materials and Systems Directories. A. When recovering or retrofitting an existing roof system, the addition of new insulation (type and thickness) may alter the fire performance characteristics of the assembly. Building owners or their SURE-WELD TPO 07/2025 6 designated representatives shall consult the local code enforcement agency to avoid potential code violation. B. Carlisle recommends the use of Carlisle supplied products for use with Sure-Weld Roofing Systems. The performance or integrity of products by others, when selected by the specifier and accepted as compatible by Carlisle, is not the responsibility of Carlisle and is expressly disclaimed by the Carlisle warranty. C. This roofing system must be installed by a Carlisle Authorized Roofing Applicator in compliance with drawings and specifications as approved by Carlisle SynTec. D. There must be no deviations made from Carlisle's specifications or Carlisle's approved shop drawings without the PRIOR WRITTEN APPROVAL of Carlisle SynTec. E. After completion of the installation, upon request, an inspection shall be conducted by a Field Service Representative (FSR) of Carlisle SynTec to ascertain that the membrane roofing system has been installed according to Carlisle's published specifications and details applicable at the time of bid. This inspection is to determine whether a warranty shall be issued. It is not intended as a final inspection for the benefit of the owner. F. Provide polyisocyanurate insulation that meets PIMA Quality Mark Certified LTTR value through third party verification meeting ASTM C 1289, Type II, Class 1, Grade 2. G. Coordination between various trades is essential to avoid unnecessary rooftop traffic over completed sections of the roof and to prevent subsequent damage to the membrane roofing system. H. The solar reflectance of this roofing product may decrease over time due to environmental defacement such as dirt, biological growth, ponded water, etc. The roof should be monitored at regular intervals and maintained or cleaned when necessary to assure the maximum solar reflectance. I. Refer to the Design Reference DR-07 “CRRC/LEED Information” for information. (i.e. solar emittance, solar reflectance and recycled content.) 1.04 Submittals A. To ensure compliance with Carlisle's minimum warranty requirements, the following projects should be forwarded to Carlisle for review prior to installation, preferably prior to bid: 1. Air pressurized buildings, canopies and buildings with large openings where the total wall openings exceed 10% of the total wall area on which the openings are located (such as airport hangars, warehouses and large maintenance facilities). 2. Cold storage buildings and freezer facilities. 3. Adhered Roofing System over 250' in height for projects with warranties up to 15 years. 4. Adhered Roofing System over 100' in height for projects with warranties greater than 15 years. 5. Mechanically Fastened Roofing System projects over 100’ in height regardless of warranty duration. 6. Projects where the Sure-Weld membrane is expected to come in direct contact with petroleum-based products or other chemicals. 7. Mechanically Fastened systems specified with a fastener length exceeding 12 inches. B. Along with the project submittals (shop drawings and Request for Warranty), the roofing contractor must include pullout tests when results are below the requirements identified in this specification. C. Shop drawings must be submitted to Carlisle by the Carlisle Authorized Roofing Applicator along with a completely executed Notice of Award (Page 1 of Carlisle's Request For Warranty form) for approval. Approved shop drawings are required for inspection of the roof and on projects where on-site technical assistance is requested. SURE-WELD TPO 07/2025 7 Shop drawings must include: 1. Outline of roof and size 2. Deck type (for multiple deck types) 3. Location and type of all penetrations 4. Perimeter and penetration details 5. Key plan (for multiple roof areas) with roof heights indicated 6. Sheet width and number of perimeter sheets for Mechanically Fastened systems 7. Fastener type, length and maximum spacing (for membrane securement) for Reinforced Mechanically Fastened systems. Along with the project submittals (shop drawing and Request for Warranty), the roofing contractor must include pullout test results when the results are below the requirements identified in, Table included in Design Reference DR-06 “Withdrawal Resistance Criteria”. When field conditions necessitate modifications to originally approved shop drawings, a copy of the shop drawing outlining all modifications must be submitted to Carlisle for revision and approval prior to inspection and warranty issuance. D. As-Built Projects (roofing systems installed prior to project approval by Carlisle) The Carlisle Authorized Applicator may supply Carlisle with an As-Built drawing for a project completed prior to Carlisle's approval. The As-Built drawings: 1. Must conform to Carlisle's most current published specifications and details applicable at the time of bid. 2. Must be submitted along with a completely executed Notice of Completion. 3. Must include the items identified in Paragraph 1.04.C. NOTE: As-Built projects are not recommended for those projects referenced in Paragraph 1.04A in order to ensure Carlisle warranty requirements have been met. E. Notice of Completion (Page 2 of the Carlisle Request for Warranty form) After project completion, a Notice of Completion must be submitted to Carlisle to schedule the necessary inspection of the project prior to issuance of the Carlisle Warranty. 1.05 Warranty A. A Total System Warranty is available for roofing systems on commercial buildings within the United States and applies only to products manufactured or marketed by Carlisle SynTec. The total system is defined as membrane, flashings, adhesives, sealants and other Carlisle brand products utilized in the installation. For a complete description of these products, refer to the Part II “Products” Section in this Specification and Spec Supplement “Related Products” P-01. See Tables Below for information regarding Warranted Systems and Design Criteria: TABLE I - Minimum Membrane Thickness for Various Warranty Options Identifies minimum membrane thickness for Reinforced membranes used in adhered or mechanically fastened roofing systems. TABLE II - Mechanically Fastened Roofing Systems – TPO Membrane Fastening Criteria - Steel/Concrete Decks Identifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The assemblies are categorized based on various building height and specific wind speed warranty coverage. TABLE III - Mechanically Fastened Roofing Systems – TPO Membrane Fastening Criteria – Plywood or OSB Decks Identifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The assemblies are categorized based on various building height and specific wind speed warranty coverage. TABLE IV - Mechanically Fastened Roofing Systems – TPO Membrane Fastening Criteria – Up to 20 Yrs - Lightweight Insulating Concrete over Steel / Gypsum / Cementitious Wood Fiber Decks Identifies fastening density, field membrane width and number perimeter sheets required for the various wind zones. The assemblies are categorized based on various building height and specific wind speed warranty coverage. SURE-WELD TPO 07/2025 8 TABLE V - Adhered Roofing Systems - Underlayment and Fastening Density for TPO Assemblies with Warranties Up to 20 Yrs Identifies required underlayments for adhered roofing systems with Warranties up to 20 year based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. TABLE VI - Adhered Roofing Systems - Underlayment and Fastening Density for TPO SAT Assemblies with Warranties Up to 20 Yrs Identifies required underlayments for adhered roofing systems with Warranties up to 20 year based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. TABLE VII - Adhered Roofing Systems - Underlayment and Fastening Density for TPO Assemblies with Warranties - 25 to 30 YR Identifies required underlayments for adhered roofing systems with Warranties from 25 to 30 year based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. TABLE VIII - Adhered Roofing Systems - Underlayment and Fastening Density for TPO SAT Assemblies with Warranties – 25 to 30 YR Identifies required underlayments for adhered roofing systems with Warranties from 25 to 30 year based on the various wind speed coverages available. The Table also identifies fastening density or adhesive bead spacing and required edge terminations. SURE-WELD TPO 07/2025 9 Sure-Weld TPO Membrane Hail - 1” Dia. Hail Coverage requires a minimum of 60-mil TPO Adhered to cover board. - 2” Dia. Hail Coverage requires 80-mil TPO Adhered to cover board. Additional Design Requirement: - Cover board (SecurShield HD, SecurShield HD Eco, SecurShield HD Plus, or StormBase Composite, DensDeck Prime, DensDeck StormX Prime or Securock, DEXcell® Glass Mat, DEXcell FA™ Glass Mat, DEXcell FA VSH®, DEXcell® Cement Board – Adhered Only). Puncture - Minimum 80-mil TPO Adhered or Mechanically Fastened. - Carlisle’s Accidental Puncture Warranty covers labor hours and material used during the repair. Maximum labor and material hours are dependent upon system design. Refer to the Warranty Availability Quick Reference Guide for coverage. Table I Mechanically Fastened or Adhered Membrane Systems Warranty Options (9) Warranty Duration Sure-Weld TPO Membranes Warranty Wind Speed Coverage Minimum Membrane Thickness (2) Additional Membrane Coverage 55, 72, 80 or 90 mph 100 mph 110 to 120 mph Adhered Mech. Fastened Adhered Mech. Fastened Adhered Mech. Fastened Additional Puncture Hail 5,10, or 15 year √ √ √ N/A (1) √ N/A Sure-Weld 45-mil See Below See Below 20 year √ (3) √ √ N/A √ N/A Sure-Weld 60-mil (4) See Below See Below 25 year (9) √ √ √ N/A N/A N/A Sure-Weld 80-mil (5) See Below See Below 30 year (9) √ √ √ N/A N/A N/A Sure-Weld 80-mil (5) See Below See Below Notes: N/A = Not Acceptable √= Acceptable (1) Contact Carlisle for specific requirements. (2) All “T-Joints” must be overlaid with appropriate flashing material when using 60- or 80-mil TPO. (3) Aqua Base 120 adhesive may be used for projects with 20 year maximum warranty and wind speed coverage up to 72 mph. (4) Spectro-Weld OR Sure-Weld SAT TPO 60-mil membranes may be used in lieu of Sure-Weld 60-mil membrane. (5) Spectro-Weld 80-mil membrane OR Sure-Weld SAT TPO 80-mil membrane can be used in lieu of Sure-Weld 80-mil membrane. Sure-Weld 80-mil TPO in Special Colors are limited to Warranties Up to 20 Year. (6) Not Used. (7) Not Used. (8) Not Used. (9) Enhancements may be required for certain flashing details. Published details must be referenced for applicable requirements. SURE-WELD TPO 07/2025 10 Table II TPO Membrane Fastening Criteria (All Warranties) for Mechanically Fastening Roofing Systems 22 GA. Steel Deck or Structural Concrete Only Caution: Projects with 25 or 30 year warranties an additional perimeter sheet is required beyond those listed in the table below. Projects with 25- or 30-year warranties the use of 12’ wide sheets is NOT PERMITTED Peak Gust Wind Speed Warranty Max. Building Height Min. Number of Perimeter Sheets Field* Membrane Width Perimeter* Sheet Width Fastening Density* (Field & Perimeter Sheets) Building Distance from Coastline Greater than 7 miles 3 to 7 miles Less than 3 miles 55 MPH Up to 60' 1 2 3 12' or 10’ 6' 12" O.C. 8' 4' 12" O.C. 61' to 100' 2 2 3 10' 6' ** See Note 8' 4' 12" O.C. 72 MPH Up to 60' 2 2 3 12' or 10’ 6' 12" O.C. 8' 4' 12" O.C. 61' to 100' 3 4 4 10' 6' ** See Note 8' 4' 12" O.C. 80 MPH Up to 60' 3 3 4 10' 6' ** See Note 8' 4' 12" O.C. 61' to 100' 3 4 4 10' 6' ** See Note 8' 4' 12" O.C. 90 MPH Up to 60' 3 4 4 10' 6' ** See Note 8' 4' 12" O.C. 61' to 100' 4 5 5 10' 6' ** See Note 8' 4' 12" O.C. *Using HP-X™ Fasteners for steel decks and HD 14-10 or CD-10 for structural concrete decks. ** Structural Concrete Decks use 12” O.C. spacing utilizing HD 14-10 or CD-10. Steel Decks use 6” O.C. utilizing HP-X Fasteners. Steel Decks use 12” O.C. spacing utilizing HP-Xtra Fasteners. SURE-WELD TPO 07/2025 11 TPO Membrane Fastening Criteria (Up to 20 Year Warranty – Up to 60’ Building Height) for Mechanically Fastening Roofing Systems Wood (Plywood or OSB) Decks Table III Deck Type Projected Pull-Out Values Min. Number of Perimeter Sheets Field Membrane Width Perimeter Sheet Width Fastening Density (Field & Perimeter Sheets) Building Distance from Coastline Greater than 7 miles 3 to 7 miles Less than 3 miles 55 MPH 7/16" OSB 210 lbs 2 3 3 10' 6'* 9" O.C. 2 3 3 8' 4'* 12" O.C. 15/32" 3-Ply Plywood 240 lbs 2 2 3 8' 4'* 12" O.C. 15/32" 5-Ply Plywood 530 lbs 1 2 3 10' 6' 12" O.C. 5/8" OSB 310 lbs 2 3 3 10' 6'* 12" O.C. 2 3 3 8' 4'* 12" O.C. 72 MPH 15/32" 3-Ply Plywood 240 lbs 2 3 3 8' 4'* 12" O.C. 15/32" 5-Ply Plywood 530 lbs 2 3 3 10' 6' 12" O.C. 5/8" OSB 310 lbs 2 3 3 8' 4'* 12" O.C 80 MPH Contact Carlisle for Approval and Evaluation *Maximum duration for OSB NOT to exceed 20 Years. SURE-WELD TPO 07/2025 12 Table IV TPO Membrane Fastening Criteria Up to 20 Yr Warranty for Mechanically Fastening Roofing Systems Lightweight Insulating Concrete over Steel / Gypsum / Cementitious Wood Fiber Peak Gust Wind Speed Warranty Building Height 50’ Max. Min. Number of Perimeter Sheets Field Membrane Width Perimeter Sheet Width Fastening Density (Field & Perimeter Sheets) Building Distance from Coastline Deck Type Greater than 7 miles 3 to 7 miles Less than 3 miles 55 MPH Lightweight Concrete over Steel Deck 2 3 (1) N/A 12’ 6’ 12" O.C. 1 2 4 10' 6’ 12" O.C.(2) 1 2 3 8’ 4’ 12" O.C.(3) Gypsum Deck or Cementitious Wood Fiber 2 (3) 3 N/A 10’ 6’ 9" O.C. 2 (3) 3 4 (4) 8’ 4’ 12" O.C. N/A is Not Acceptable (1) Fastening Density must be secured 6” O.C. (2) For Buildings 51’ to 75’ with 10’ field sheets – Fastening Density must be increased to 9” O.C. (3) Acceptable for Buildings up to 75’ in height. (4) Fastening Density must be increased to 9” O.C. Additional Design Considerations (Up to 20 YR Warranty) 1-Membrane configuration and fastening density in Table above is based on HP-X Fasteners penetrating metal pan below Lightweight Insulating Concrete and for Polymer Gyptec Fasteners engaging into Gypsum and Cementitious Fiber Decks. 2-See Design Reference DR-06 “Withdrawal Resistance Criteria” for more information. SURE-WELD TPO 07/2025 13 Table V Underlayment/Insulation & Required Attachment Assemblies Up to 20 YR Warranty for TPO Adhered Roofing Systems Other Requirements are Listed in Additional Design Considerations following this Table All Carlisle Products listed for higher wind speed coverage can also be used for Warranties for a lower speed coverage. (i.e. 72 MPH underlayment may be used for 55 MPH underlayment) Peak Gust Wind Speed Warranty Minimum Membrane Underlayment* Underlayment/Insulation Attachment Metal Edging # of Fasteners per 4' x 8' board size Adhesive Ribbon Spacing for 4' x 4' size board Field Perimeter 55 or 72 MPH 1” (20 psi) Polyisocyanurate or 1” (20 psi) Polyisocyanurate Eco 16 12" (5)(6) 6" (5) SecurEdge Drip Edge 1-1/2" (20 psi) Polyisocyanurate or 1-1/2” (20 psi) Polyisocyanurate Eco 10 2" (20 psi) Polyisocyanurate or 2” (20 psi) Polyisocyanurate Eco 8 1/2" SecurShield HD or 1/2” SecurShield HD Eco (1)(2) 12 1/4" DensDeck Prime, 1/4” Securock or 1/4” DEXcell FA VSH® (1) 12 80 MPH 1/2" SecurShield HD Plus (1) (2) 8 12" (5)(6)(7) 6" (5)(7) SecurEdge Drip Edge (11) 1/2” HP Recovery Board (1) 16 2” SecurShield HD Composite 6 1/2” SecurShield HD and 1/2” SecurShield HD Eco (1) 16 1/2" DensDeck Prime, 1/2” Securock, or 1/2” DEXcell FA VSH® (1) 8 1-1/2" (25-psi) Polyisocyanurate or 1-1/2” (25 psi) Polyisocyanurate Eco 10 2" (25 -psi) Polyisocyanurate or 2” (25 psi) Polyisocyanurate Eco 8 90 MPH 1/2" DensDeck Prime, 1/2” Securock, 1/2” EcoStorm VSH, or 1/2” DEXcell FA VSH® (1) 12 6"(9) 6"(7)(8) SecurEdge Drip Edge (3), or SecurEdge EX Drip Edge 1/2" SecurShield HD, 1/2” SecurShield HD Eco, 1-1/2" (20-psi) SecurShield Polyiso or 1-1/2” (20-psi) SecurShield Eco (1) (2), 16 1/2" SecurShield HD Plus (1) (2) 12 2" (20-psi) SecurShield Polyiso, 2” (20-psi) SecurShield Eco or 2” SecurShield HD Composite 8 1-1/2” StormBase (OSB/Polyiso Composite) 8 1-1/2” Insulfoam HD Composite 16 100 MPH 2" (25-psi) SecurShield Polyiso or 2” (25-psi) SecurShield Eco 16 FS FS SecurEdge Drip Edge (3), or SecurEdge EX Drip Edge 110 MPH 1-1/2” StormBase (OSB/Polyiso Composite) or 1/2” EcoStorm VSH (1) 16 FS FS SecurEdge EX Drip Edge 1/2” SecurShield HD Plus (1) (2) 120 MPH 5/8" DensDeck Prime, 5/8” Dens Deck StormX Prime 5/8” Securock, 5/8” DEXcell FA VSH® (1) 16 FS FS SecurEdge EX Drip Edge 1-1/2” StormBase (OSB/Polyiso Composite) or 1/2” EcoStorm VSH (1) (2) 17 1/2" SecurShield HD Plus (1) (2) 24 2” SecurShield HD Composite 16 FS = Full Spray or Ribbons @ 4" O.C. SURE-WELD TPO 07/2025 14 *For Direct Application over Wood Decks and Lightweight Cellular Concrete, Refer to Roof Deck & Substrate Criteria Table. (1) For steel decks (new or tear-off) cover boards must be installed over a min. 1" thick approved Carlisle Insulation. (2) 1/2" SecurShield HD and SecurShield HD Eco limited to 90 mph. 1/2” SecurShield HD Plus limited to 120 mph. (3) Carlisle HP or HP-X Fasteners must be used to secure SecurEdge Drip Edge to perimeter wood nailers. (4) Membrane securement is required at the base of the SecurEdge Fascia waterdam. (5) Gravel Surface BUR - Field @ 6" O.C. / Perimeter @ 4" O.C. (6) Steel Decks - Field & Perimeter @ 6" O.C. (7) Cementitious Wood Fiber - Field @ 6" O.C. / Perimeter @ 4" O.C. (8) Smooth BUR - Field @ 6" O.C. / Perimeter @ 4" O.C. (9) Gravel Surface BUR – FS (10) Reduced fastening (11 fasteners per 4 x 8 board) is acceptable on Reroof/No Tear off projects with a maximum roof height of 40’. (11) May be fastened with ring shank nails staggered 4" on center. Carlisle HP or HP-X Fasteners may also be used fastened 12" on center. Table V - Additional Design Considerations (Up to 20 YR Warranty) 1 – Refer to Table I paragraph 1.05 for warranty options available with various membrane thickness. 2 - Building height shall not exceed 100'* 3- Acceptable decking: 22-gauge or heavier steel, structural concrete, 1-1/2" wood plank, or 15/32" plywood.** 4 - For Building heights between 51-100', enhance 12'-wide perimeter with 50% more fasteners and plates. 5 - See DR-05 for insulation fastening patterns. * Projects where building height exceeds 100’ shall be submitted to Carlisle for review. ** 16 fasteners per 4’ x 8’ board are required for the following decks: OSB, gypsum, cementitious, wood fiber (Tectum), lightweight insulated concrete over steel roof deck thinner than 22-gauge and steel roof deck thinner than 22-gauge. Warranties are limited to a 20-year, 72-mph wind speed.