Loading...
HomeMy WebLinkAbout20251123 149 Lake Ave. St. Paul's Equipment Install Mechanical SpecsUpstate New York REGION 54 PHONE: (585) 348 - 9118 EMAIL: reg54@captiveaire.com FOR QUESTIONS, CALL THE HOOD INFORMATION - JOB#8293651 1 2 5424 ND-2 5424 ND-2 CAPTIVEAIRE CAPTIVEAIRE 6' 0" 4' 0" 600 DEG 600 DEG I I HEAVY HEAVY 225 225 1350 900 4" 4" 14" 10" 1350 900 1263 1650 -0.480" -0.551" 430 SS WHERE EXPOSED 430 SS WHERE EXPOSED LEFT RIGHT ALONE ALONE HOOD NO TAG MODEL MANUFACTURER LENGTH MAX COOKING TEMP TYPE APPLIANCE DUTY DESIGN CFM/FT TOTAL EXH CFM EXHAUST PLENUM RISER(S) WIDTH LENG HEIGHT DIA CFM VEL SP HOOD CONSTRUCTION HOOD CONFIG END TO END ROW HOOD INFORMATION 1 2 CAPTRATE SOLO FILTER CAPTRATE SOLO FILTER 4 2 20" 20" 16" 20" 85% SEE FILTER SPEC 85% SEE FILTER SPEC 3 2 L55 SERIES E26 L55 SERIES E26 NO NO RIGHT 12"x54"x24"TANK FS 4.0/4.0 SC-310110MA 1 LIGHT 1 FAN YES YES 295 LBS 549 LBS HOOD NO TAG FILTER(S) TYPE QTY HEIGHT LENGTH EFFICIENCY @ 7 MICRONS LIGHT(S) QTY TYPE WIRE GUARD UTILITY CABINET(S) LOCATION SIZE FIRE SYSTEM TYPE SIZE ELECTRICAL MODEL # SWITCHES QUANTITY FIRE SYSTEM PIPING HOOD HANGING WEIGHT HOOD OPTIONS 1 2 BACKSPLASH 80.00" HIGH X 133.00" LONG 430 SS VERTICAL. LEFT SIDESPLASH 80.00" HIGH X 54.00" LONG 430 SS VERTICAL. LEFT END STANDOFF (FINISHED) 1" WIDE 54" LONG INSULATED. BACKSPLASH - INSIDE CORNER 80.00" HIGH X 2.00" LEG LENGTH 430 SS VERTICAL. BALANCE DAMPERS. RISER SENSOR INSTALL 6IN PLEN. LEFT WALL AS END PANEL. RIGHT QUARTER END PANEL 23" TOP WIDTH, 0" BOTTOM WIDTH, 23" HIGH 430 SS. BALANCE DAMPERS. RISER SENSOR INSTALL 6IN PLEN. HOOD NO TAG OPTION 1500500 FLOW RATE (CFM) 1000 0.00 0 0.50 PR E S S U R E D R O P ( i n . H 2 0 ) PRESSURE DROP VS. FLOW RATE RR SPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTER A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND COMPONENTS WHEN ASSEMBLED. 2-INCH DEEP HOOD CHANNEL(S). TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FR A C T I O N A L E F F I C I E N C Y ( % ) 0 0.1 20 40 1.0 PARTICLE DIAMETER (UM) 10.0 EFFICIENCY VS. PARTICLE DIAMETER 60 80 100 THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. TE A N S F ACCORDANCE No. 96 NFPA WITH BUILT IN S LI DTE RO CH B N R A N I , O R M . YR OR LAIGNTSB AT CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96. NSF STANDARD #2. UL STANDARD #1046. INT. MECH. CODE (IMC). ULC-S649. 1.00 1.50 2.00 2.50 3.00 3.50 MANUFACTURER APPROVED FOR USE IN SOLID FUEL APPLICATIONS AS A SPARK ARRESTER. GREASE DUCT & CHIMNEY SPECIFICATIONS: PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATION GUIDE. PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12' ON CENTER. PER MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN HORIZONTAL RUNS. IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. § CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF LISTED, PRE-FABRICATED ROUND GREASE EXHAUST DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, MINIMIZE INSTALLATION AND INSPECTION TIMES, AND ENSURE DUCT IS LIQUID TIGHT CUSTOMER APPROVAL TO MANUFACTURE: APPROVED AS NOTED APPROVED WITH NO EXCEPTION TAKEN REVISE AND RESUBMIT SIGNATURE YOUR TITLE DATE HEIGHT REQUIRED TO VERIFY THAT HOOD FITS SPACE AND TO SIZE THE ENCLOSURE PANELS ___' - ___" VERIFY CEILING HEIGHT HVAC DISTRIBUTION NOTE HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. PATENT NUMBERS EXHAUST HOODS ND-2/BD-2/SND-2 (CANADA) - CA PATENT 2520435 C. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUT. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL ALL-THREAD. HOOD CORNER HANGING ANGLE (WEIGHT BEARING ANCHOR POINT FOR HOOD). HOOD CORNER HANGING ANGLE 1/2" - 13 TPI GRADE 5 (MINIMUM) STEEL HEX NUTS. 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHER. ASSEMBLY INSTRUCTIONS HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 FT-LBS. (HARDWARE BY INSTALLER) CLEARANCE TO COMBUSTIBLES HOODS #SURFACE *CLEARANCE 1 TOP 18" FRONT 0" BACK 18" LEFT 0" RIGHT 18" 2 TOP 18" FRONT 0" BACK 18" LEFT 18" RIGHT 0" - *0" CLEARANCE TO COMBUSTIBLES CONFORMS TO UL710 STANDARD. - HOOD MOUNTED UTILITY CABINETS REQUIRE 36" SERVICE CLEARANCE. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 8293651 MASTER DRAWING perry.hosm 1 10/16/2025 St . P a u l ' s L u t h e r a n - 1 0 F t O p t i o n 3/4" = 1'-0" 14 9 L a k e A v e , Up s t a t e N e w Y o r k 34 9 W C o m m e r c i a l S t . , S u i t e # 1 9 0 0 , E a s t R o c h e s t e r , N Y , 1 4 4 4 5 P H O N E : ( 5 8 5 ) 3 4 8 - 9 1 1 8 F A X : 9 1 9 - 2 2 7 - 5 9 2 7 E M A I L : r e g 5 4 @ c a p t i v e a i r e . c o m SA R A T O G A S P R I N G S , N Y , 1 2 8 6 6 6' 0"NOM./6' 0.00"OD. 6'-1.00" OVERALL LENGTH 54" 1" LAYER OF INSULATION FACTORY INSTALLED IN 1.00" END STANDOFF MEETS 0" REQUIREMENTS CLEARANCE TO COMBUSTIBLE SURFACES. 1" 3" § 36"36" 11" ∅14" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. INSTALLER MUST CONFIRM HOOD IS INSTALLED SUCH THAT THE SPECIFIED WALL, ACTING AS AN END PANEL, IS MATED TIGHT TO THE CORRECT END OF HOOD TO ACHIEVE A REDUCED MINIMUM EXHAUST CFM LISTING. NON-COMPLIANCE WILL NULLIFY THE ETL LISTING, VOID THE MANUFACTURER'S WARRANTY, AND HOLD THE CONTRACTOR LIABLE FOR ANY AND ALL LOSSES, COSTS, AND EXPENSES RELATED TO THE NON-CONFORMANCE OF THE MANUFACTURER'S SPECIFIED INSTRUCTION. THE WALL ACTING AS AN END PANEL MUST EXTEND NO LESS THAN 20" FROM THE INTERSECTING WALL ON WHICH HOOD IS MOUNTED AND MUST EXTEND NO LESS THAN 20" UNDER BOTTOM OF HOOD TO BE ELIGIBLE FOR REDUCED MINIMUM EXHAUST CFM LISTING. 4' 0"NOM./4' 0.00"OD. 5'-0.00" OVERALL LENGTH 54" 12" UTILITY CABINET. 24 X 1 8 X 8 . 6 2 B O X 3" § 36"12" 11" ∅10" U.L. LISTED L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY. 11'-1.00" OVERALL LENGTH PLAN VIEW - HOOD #1 6' 0.00" LONG 5424ND-2 PLAN VIEW - HOOD #2 4' 0.00" LONG 5424ND-2 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. BALANCE DAMPERS. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). BACKSPLASH 80.00" HIGH X 133.00" LONG. LEFT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. SECTION VIEW - MODEL 5424ND-2 HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. BALANCE DAMPERS. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). 23" 23" RIGHT QUARTER END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. SECTION VIEW - MODEL 5424ND-2 HOOD - #2 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. BACKSPLASH HEIGHT - BACKSPLASH IS NOT INSULATED AND IS UNSUITABLE FOR INSTALL AGAINST COMBUSTIBLE WALLS BACKSPLASH PANELS SLIDE INTO DIVIDER BAR NON-COMBUSTIBLE WALL LENGTH SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 8293651 MASTER DRAWING perry.hosm 2 10/16/2025 St . P a u l ' s L u t h e r a n - 1 0 F t O p t i o n 3/4" = 1'-0" 14 9 L a k e A v e , Up s t a t e N e w Y o r k 34 9 W C o m m e r c i a l S t . , S u i t e # 1 9 0 0 , E a s t R o c h e s t e r , N Y , 1 4 4 4 5 P H O N E : ( 5 8 5 ) 3 4 8 - 9 1 1 8 F A X : 9 1 9 - 2 2 7 - 5 9 2 7 E M A I L : r e g 5 4 @ c a p t i v e a i r e . c o m SA R A T O G A S P R I N G S , N Y , 1 2 8 6 6 FIRE SYSTEM INFORMATION - JOB#8293651 1 TANK FS 4.0/4.0 40 26 FIRE CABINET RIGHT RIGHT, HOOD 2 FIRE SYSTEM NO TAG TYPE SIZE MAX FP DESIGN FP INSTALLATION SYSTEM LOCATION ON HOOD GAS VALVE(S) 1 SC ELECTRICAL 1.250 CAPTIVEAIRE SYSTEMS FIRE SYSTEM NO TAG TYPE SIZE SUPPLIED BY FIRE SYSTEM PARTS LIST KEY 1 0 - 0 - TANK FIRE SUPPRESSION POST-DISCHARGE PROCEDURE UTILITY CABINET LABEL SHEET. 0 - 0 - TANK FIRE SUPPRESSION MAINTENANCE GUIDE UTILITY CABINET LABEL SHEET. 0 - 0 - 12-F28021-32144-OT-360 DUCT FIRE THERMOSTAT WITH 12 FOOT WIRE LEADS. NO, CLOSE ON TEMP RISE AT 360°F. (A0034310). 0 - 0 - 4429K153 1/2" MALE NPT TO 1/2" FEMALE NPT ELBOW, BRASS. 0 - 0 - 4429K422 1/2" X 1/4" BRASS REDUCING BUSHING. 0 - 0 - 79525 1/2" 90 PRO-PRESS ELBOW WITH 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 79580 1/2" X 1/2" PRO-PRESS TEE X 1/2” NPT FEMALE CONNECTION, VIEGA. 0 - 0 - 87-120042-001 SECONDARY ACTUATOR VALVE (SVA) - SINGLE ACTUATOR, REQUIRES PRIMARY RELEASE ACTUATOR, TANK FIRE SUPPRESSION. 0 - 0 - 87-120045-001 HOSE, SECONDARY ACTUATOR HOSE, 7.5" BRAIDED STAINLESS STEEL, TANK FIRE SUPPRESSION. 0 - 0 - 87-300001-001 TANK - PRESSURIZED TANK USED FOR TANK FIRE SUPPRESSION. 0 - 0 - 87-300030-001 PRIMARY ACTUATOR KIT (PAK) - ACTUATOR AND RELEASE SOLENOID ASSEMBLY, ONE NEEDED PER FIRE SYSTEM, SUPERVISED, TANK FIRE SUPPRESSION. 0 - 0 - 87-300033-001 DIN CONNECTOR, CANFIELD PART #5J560-201-EU0A, TANK FIRE SUPPRESSION, SUBMINATURE SOLENOID CONNECTION (CED VENDOR 30377). 0 - 0 - 87-300152-001 HARDWARE, SVA BOLTS, TANK FIRE SUPPRESSION. 0 - 0 - 98694A115 HARDWARE, DATANKLOCK LOCKING BRACKET SQUARE NUTS 5/16" ZINC, TANK FIRE SUPPRESSION. 0 - 0 - A0034332 JUNCTION BOX FOR MANUAL PULL STATION. 1.5" DEEP BACK BOX, RED COLOR. 0 - 0 - A31484 1/4" NPT SCHRADER VALVE AND CAP, JB INDUSTRIES. 1/4" FLARE X 1/4" MPT HALF UNION. USED ON TANK SERVICE PORT. 0 - 0 - DATANKLOCK DISCHARGE ADAPTER TANK LOCKING PLATE FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - SLPCON-03FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 2' GAP. KIT CONTAINS 5 FEET OF BLACK MG WIRE, 5 FEET OF TAN MG WIRE, 3 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - SLPCON-05FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 4' GAP. KIT CONTAINS 7 FEET OF BLACK MG WIRE, 7 FEET OF TAN MG WIRE, 5 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - SLPCON-10FT SUPERVISED LOOP CONNECTION KIT. CONTAINS THE PARTS NEEDED TO CONNECT THE SUPERVISED LOOP BETWEEN END TO END HOODS WITH LESS THAN A 9' GAP OR BACK TO BACK HOODS. KIT CONTAINS 12 FEET OF BLACK MG WIRE, 12 FEET OF TAN MG WIRE, 10 FEET OF FLEXIBLE CONDUIT, AND TWO 7/8" CONNECTORS. 0 - 0 - TANK STRAP TANK STRAP - USED FOR TANK FIRE SUPPRESSION. 0 - 0 - TFS-UCTANKBRACKET TANK BRACKET FOR FIRE SYSTEM TANK INSTALLATION IN UTILITY CABINETS, TANK FIRE SUPPRESSION. 0 - 0 - WK-283952-000 DISCHARGE ADAPTER, TANK FIRE SUPPRESSION. 34 - 34 - A0034331 RED COLOR - 24VDC SINGLE ACTION MANUAL ACTUATION DEVICE (PUSH/PULL STATION) WITH PROTECTIVE COVER, ONE (1) NORMALLY OPEN CONTACT. 1 1 2 2 1 1 2 1 1 2 1 1 8 4 1 1 2 1 1 1 6 2 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 FIRE SYSTEM NO TAG KEY NUMBER - PART DESCRIPTION QTY BY FACTORY QTY BY DIST FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. 11" ∅14" HOOD FRONT HOOD BACK HOOD # 1 JOB # 8293651 FS # 1 MODEL: ND-2 SIZE: 54"x24" LENGTH: 6' 0" TA N K O V E R L A P P I N G PR O T E C T I O N - 3 6 / S H E L F HI G H P R O X I M I T Y 60 . 0 0 " L X 3 0 . 0 0 " D DUCT S 360 OL-F OL-F 25.00" 21.50" OL-F 21.50" OL-F NOZZLE HEIGHT 35-50" FROM COOKING SURFACE. (45.25") 18.00"36.00"18.00"48.00" SLPCON-10FT KIT 11" ∅10" HOOD FRONT HOOD BACK HOOD # 2 JOB # 8293651 FS # 1 MODEL: ND-2 SIZE: 54"x24" LENGTH: 4' 0" DUCT S 360 OL-F OL-F SLPCON-05FT KIT SLPCON-03FT KIT - SYSTEM REQUIRES A MINIMUM OF 7 FT OF EQUIVALENT PIPE LENGTH BETWEEN TANK AND NEAREST APPLIANCE NOZZLE FOR MOST APPLIANCES. EACH 90 DEGREE ELBOW ADDS 1.3 FT OF EQUIVALENT LENGTH. SEE MANUAL FOR DETAILS 1 631 7 2 5 ALTERNATE FIELD-CONNECTION POINT PL E N U M PL E N U M NOTES - FIELD PIPE DROPS AS SHOWN PIPING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS. - FIELD INSTALLED DROP: FACTORY WILL PROVIDE QTY 2 60IN LONG PIECES OF CHROME PLATED PIPING SHIPPED LOOSE TO BE FIELD-INSTALLED. - SHIP LOOSE DROP: FACTORY WILL PROVIDE THE EXACT CHROME PIPE LENGTH NEEDED SHIPPED LOOSE TO BE FIELD-INSTALLED. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. - OVERLAPPING COVERAGE SHALL NOT BE USED ON ANY APPLIANCE WITH AN OBSTRUCTION. - IF APPLICABLE, EXTENDED PRE-PIPED DROPS ARE SHIPPED LOOSE. - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. - THIS PRE-ENGINEERED FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS. - OL-F NOZZLE PART NUMBER REPLACES 3070-3/8H-10-SS JOB #: 8293651. JOB NAME: ST. PAUL'S LUTHERAN - 10 FT OPTION. SYSTEM SIZE: TANK-SP-2 DESIGN FP: 26. MAXIMUM FP: 40. HOOD # 1 6' 0.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 14" DIA. HOOD # 1 METAL BLOW-OFF CAPS INCLUDED. HOOD # 2 4' 0.00" LONG x 54" WIDE x 24" HIGH. RISER # 1 SIZE: 10" DIA. HOOD # 2 METAL BLOW-OFF CAPS INCLUDED. - HEAVY-DUTY APPLIANCES (RATED 600°F) WILL REQUIRE AN ADDITIONAL DOWNSTREAM FIRESTAT IN THE EVENT THAT THE DUCTWORK CONTAINS ANY HORIZONTAL RUNS OVER 25 FT IN LENGTH. - MEDIUM TO LIGHT-DUTY APPLIANCES (RATED 450°F) WILL NOT REQUIRE ANY ADDITIONAL DOWNSTREAM DETECTION. AGENT DISTRIBUTION PIPING LIMITATIONS PIPE SECTION MAX PIPE LENGTH (FT) MAX SUPPLY LINE TO FIRST OVERLAPPING NOZZLE 42 OVERLAPPING NOZZLE APPLIANCE BRANCH 10 DEDICATED NOZZLE APPLIANCE BRANCH 10 PRESSURE SUPERVISION SWITCH. PRIMARY ACTUATOR RELEASE. 4 GALLON TANK. 7 6 5 4 2 1 LEGEND - FIRE CABINET TANK SYSTEM PRIMARY HOSE ASSEMBLY. SECONDARY ACTUATOR RELEASE.3 SECONDARY HOSE ASSEMBLY. REMOTE MANUAL ACTUATION DEVICE. 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. BALANCE DAMPERS. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). BACKSPLASH 80.00" HIGH X 133.00" LONG. LEFT WALL AS END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. SECTION VIEW - MODEL 5424ND-2 HOOD - #1 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. 21 1/2" 3" INTERNAL STANDOFF. GREASE DRAIN WITH REMOVABLE CUP. SEE HOOD TABLE. BALANCE DAMPERS. HANGING ANGLE. L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE). 23" 23" RIGHT QUARTER END PANEL. EQUIPMENT BY OTHERS. 48.0" MAX. 80" 24" NOM. 54" *6" *6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. *24" *24" CLEARANCE ABOVE HOOD RECOMMENDED FOR SERVICEABILITY. SECTION VIEW - MODEL 5424ND-2 HOOD - #2 IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. 20" CAPTRATE SOLO FILTER WITH HOOK. A.F.F. BY JOBSITE ELECTRICIAN AND ROUTED BACK STD SINGLE GANG BOX 2"X4"X2" PROVIDED TO ELECTRICAL CONTROL PANEL & INSTALLED BY JOBSITE ELECTRICIAN AND TANK MANUAL ACTIVATION DEVICE DETAIL MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC -WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN PARALLEL PER SYSTEM SCHEMATICS -USE BELDEN #6320UL OR SIMILAR WIRE C L TANK FIRE SUPPRESSION PUSH CLEAR PROTECTIVE COVER 4-5/8" 3-3/16" HOOD FIRE SYSTEM PROTECT AGAINST MUST BE INSTALLED TO ACCIDENTAL ACTIVATION MANUAL ACTIVATION DEVICE (MAD) TO BE LOCATED IN THE PATH OF EGRESS, FREE FROM OBSTRUCTION. COORDINATE LOCATION WITH FIRE SYSTEM CONTRACTOR. NOTE: RECESSED INTO SHEET ROCK 1/4". 5-3/8" 7-3/8" 1/2" CONDUIT PROVIDED & INSTALLED MANUAL DEVICE ACTIVATION 42"-48" ABOVE FINISHED FLOOR OR IN ACCORDANCE WITH LOCAL CODE INSTALL 10-20 FT FROM HOOD SYSTEM, AND AUTHORITY HAVING JURISDICTION. INCLUDES: FIELD INSTALLATION AND HOOKUP DURING NORMAL BUSINESS HOURS BY CERTIFIED INSTALLERS ONLY IN THE LOCATION NOTED ABOVE, TWO SITE VISITS ONLY (ONE VISIT TO SET PULL STATION & SYSTEM HOOKUP AND ONE VISIT FOR ONE TEST; ADDITIONAL VISITS WILL RESULT IN ADDITIONAL CHARGES), ONE MECHANICAL OR ELECTRICAL GAS VALVE PER SYSTEM AT A MAXIMUM SIZE OF 2", PERMIT, AND SYSTEM TEST. EXCLUDES: UNION LABOR & PREVAILING WAGE (LABOR & WAGES WILL BE ADDED IF APPLICABLE), GAS VALVE INSTALLATION, ELECTRICAL HOOKUP AND CONNECTIONS, HANGING OF FIRE CABINET, SHUNT TRIP, HANDHELD EXTINGUISHER(S), ON-SITE RE-PIPING DUE TO EQUIPMENT LAYOUT CHANGES. VOLTAGESIZETYPE GAS VALVE SIZING GAS VALVE DIMENSIONS DIM "A"DIM "B"DIM "C"DIM "D"DIM "F"DIM "G" PART NUMBERS GAS VALVES AND STRAINERS INSTALLATION MIN. INLET PRESSURE MAX. INLET PRESSURE FLOW AT 1 IN.W.C. DROP NATURAL GAS FLOW AT 1 IN.W.C. DROP PROPANE PIPE ORIENTATION GAS VALVE PART NUMBER STRAINER PART NUMBER GAS VALVE/STRAINER KIT ELECTRICAL 1-1/4" 120 VAC 4417K6682142657-5/8"6-3/8"5-1/8"5-15/16"13-1/2"12-1/16"(SC)EGVA1-1/4GAS VALVE FOR FS#1 0 PSI (0 IN.W.C.) 5 PSI (138 IN.W.C.) 1,925,000 BTU/HR 1,249,105 BTU/HR HORIZONTAL/VERTICAL FLOW. SOLENOID STRAINER. 4" MIN. DIM "G" DIM "D" DIM "A" DIM "F" DIM "C" DIM "B" ELECTRIC GAS VALVES ONLY:SOLENOID ORIENTATION 3/4"-2" 120VAC GAS VALVES CAN BE MOUNTED WITH THE SOLENOID IN ANY POSITION AT OR ABOVE HORIZONTAL. 2 1/2"-3" 120VAC GAS VALVES MUST BE MOUNTED WITH THE SOLENOID VERTICAL AND UPRIGHT. 24VDC GAS VALVES MUST BE MOUNTED WITH THE SOLENOID VERTICAL AND UPRIGHT. ELECTRIC GAS VALVE. ALL GAS VALVES/STRAINERS TO CALCULATE GAS FLOW FOR OTHER THAN 1 IN.W.C. PRESSURE DROP NEW BTU/HR = (BTU/HR AT 1 IN.W.C. PRESSURE DROP) X NEW PRESSURE DROP 0.5 TO CALCULATE GAS FLOW FOR OTHER THAN 0.64 SPECIFIC GRAVITY NEW BTU/HR = (BTU/HR AT 0.64) X (0.64 / NEW SPECIFIC GRAVITY) 0.5 . CALCULATIONS PROPER CLEARANCE MUST BE PROVIDED IN ORDER TO SERVICE THE STRAINERS A MINIMUM OF 4" CLEARANCE DISTANCE MUST BE PROVIDED AT THE BASE OF THE STRAINER CUSTOMER MUST VERIFY BTU CONSUMPTION AS WELL AS PRESSURE RATING SPECIFIC GRAVITY OF NATURAL GAS = 0.64, SPECIFIC GRAVITY OF LP = 1.52. SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 8293651 MASTER DRAWING perry.hosm 3 10/16/2025 St . P a u l ' s L u t h e r a n - 1 0 F t O p t i o n 1/2" = 1'-0" 14 9 L a k e A v e , Up s t a t e N e w Y o r k 34 9 W C o m m e r c i a l S t . , S u i t e # 1 9 0 0 , E a s t R o c h e s t e r , N Y , 1 4 4 4 5 P H O N E : ( 5 8 5 ) 3 4 8 - 9 1 1 8 F A X : 9 1 9 - 2 2 7 - 5 9 2 7 E M A I L : r e g 5 4 @ c a p t i v e a i r e . c o m SA R A T O G A S P R I N G S , N Y , 1 2 8 6 6 EXHAUST FAN INFORMATION - JOB#8293651 1 EF-1 1 USBI18DD-RM CAPTIVEAIRE 2250 2.000 1297 ODP,PREMIUM 2.000 1.2110 3 208 8.3 1153 FPM 486 20 FAN UNIT NO TAG QTY FAN UNIT MODEL #MANUFACTURER CFM ESP RPM MOTOR ENCL HP BHP PHASE VOLT FLA DISCHARGE VELOCITY WEIGHT (LBS) SONES FAN ACCESSORIES 1 EF-1 YES FAN UNIT NO TAG EXHAUST GREASE CUP GRAVITY DAMPER WALL MOUNT SUPPLY SIDE DISCHARGE GRAVITY DAMPER MOTORIZED DAMPER WALL MOUNT CURB ASSEMBLIES 1 # 1 EF-1 76 LBS CURB 31.000"W X 45.000"L X 20.000"H VENTED. NO ON FAN TAG WEIGHT ITEM SIZE FAN OPTIONS FAN UNIT NO TAG QTY DESCRIPTION 1 EF-1 1 UTILITY SET GREASE CUP 1 BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE 1 BI18 - INLET CONNECTION STANDARD 20" FLANGED GREASE DUCT 1 CURB MOUNTED SLED FOR USBI 18. USED TO MOUNT ON 45" L X 31" W CURB 1 BI18 - 20" DISCHARGE ADAPTER 1 UTILITY SET - FAN SLED RESTRAINED SPRING VIBRATION ISOLATORS - BI11 THRU BI20 / EQUIVALENT SIZED UTILITY SET - INDOOR/OUTDOOR USE (SET OF 6) 1 2 YEAR PARTS WARRANTY 42 1/8" 19 13/16" 14 5/8" 14" 28 1/8" 27 3/16" 25" 38 3/16" 22" 37 9/16" FEATURES: SHAFT DISCHARGE 35" ADAPTER DIA. 31 15/16" 1 1/4" 20" 20" OPTION 20" *INLET FIRESTAT LOCATION TO BE INSTALLED BY ELECTRICIAN *OUTLET 6" 2IN DRAIN - CURB MOUNTED FANS WITH VIBRATION ISOLATOR - FULL PERIMETER CURB - LIFTING HOOK POCKETS ON ALL SIDES - UL705 - UL762 & ULC-S645 (RESTAURANT MODEL) - HIGH HEAT OPERATION DIRECT DRIVE 350°F (176°C) - HEAT SLINGER - GREASE CLASSIFICATION TESTING - 2" DRAIN - MOTOR WEATHER COVER - FULLY SEALED SCROLL HOUSING - SCROLL ACCESS DOOR 36 11/16" 50 11/16" 11 9/16" 45" 20" 31" SUPPORT CURB OPTION - FLANGE 1 1/4" - 11 THRU 20 (6) ISOLATORS = USBI18 THRU 36 5 5/8" TOP VIEW FAN #1 USBI18DD-RM - EXHAUST FAN (EF-1) OPTIONS - UTILITY SET GREASE CUP. - BI - DISCHARGE ORIENTATION VERTICAL UPPER LEFT - CW INLET SIDE. - BI18 - INLET CONNECTION STANDARD 20" FLANGED GREASE DUCT. - CURB MOUNTED SLED FOR USBI 18. USED TO MOUNT ON 45" L X 31" W CURB. - BI18 - 20" DISCHARGE ADAPTER. - UTILITY SET - FAN SLED RESTRAINED SPRING VIBRATION ISOLATORS - BI11 THRU BI20 / EQUIVALENT SIZED UTILITY SET - INDOOR/OUTDOOR USE (SET OF 6). - 2 YEAR PARTS WARRANTY. 105.9 95.0 147.0 131.9 CORNER WEIGHTS ARE CALCULATED BASED ON VERTICAL DISCHARGE. SUPPORT DUCT PROPERLY BEFORE FAN TO ENSURE CORNER WEIGHTS ARE NOT AFFECTED. INLET NORMAL TEMPERATURE TEST DIRECT DRIVE DETERIORATING EFFECTS TO THE FAN WHICH THERMAL EQUILIBRIUM, AND WITHOUT ANY UNTIL ALL FAN PARTS HAVE REACHED WHILE EXHAUSTING AIR AT 350°F (176°C) EXHAUST FAN MUST OPERATE CONTINUOUSLY WOULD CAUSE UNSAFE OPERATION. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Label Description Location MT-01 Fan Motor [3] SW-01 Main disconnect switch [3] Component Identification 23 Installed Options RD - RED BL - BLUE WH - WHITE OR - ORANGE BR - BROWN BK - BLACK PK - PINK PR - PURPLE GY - GRAY GR - GREEN YW - YELLOW WIRE COLOR DENOTES FIELD WIRING DENOTES INTERNAL WIRING NOTES SW-01 BK BK MT-01 GR BK GR BK BK BK 5 6 3 4 1 2 GR EXHAUST 2.0HP-208V-3P-8.3FLA VFD: i51BP222D0000ACBSS MOTOR INFO ELECTRICAL INFORMATION MOTOR/CTRL MCA: 10.4A MOTOR/CTRL MOP: 15A DRAWING NUMBER JOB MODEL SHIP DATE Exhaust Fan Wiring EXH8293651-1 8293651 - St. Paul's Lutheran - 10 Ft O... 10/16/2025 USBI18DD-RM SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 8293651 MASTER DRAWING perry.hosm 4 10/16/2025 St . P a u l ' s L u t h e r a n - 1 0 F t O p t i o n 3/4" = 1'-0" 14 9 L a k e A v e , Up s t a t e N e w Y o r k 34 9 W C o m m e r c i a l S t . , S u i t e # 1 9 0 0 , E a s t R o c h e s t e r , N Y , 1 4 4 4 5 P H O N E : ( 5 8 5 ) 3 4 8 - 9 1 1 8 F A X : 9 1 9 - 2 2 7 - 5 9 2 7 E M A I L : r e g 5 4 @ c a p t i v e a i r e . c o m SA R A T O G A S P R I N G S , N Y , 1 2 8 6 6 ELECTRICAL PACKAGE - JOB#8293651 1 SC-310110MA UTILITY CABINET RIGHT UTILITY CABINET RIGHT HOOD # 2 1 LIGHT 1 FAN SMART CONTROLS THERMOSTATIC CONTROL W/ RELAY ON/OFF WITH SUPPLY EF-1 EXHAUST 3 2.000 208 8.3 NO TAG PACKAGE #LOCATION SWITCHES LOCATION QUANTITY OPTION FANS CONTROLLED FAN TAG TYPE ɸ HP VOLT FLA CASlink Monitor and Control - Hood control panel to support communications to cloud-based Building Management System. - Hood Control Panel to allow cloud-based Building Management System to monitor real time parameters outlined as MONITOR in the points list. - Hood Control Panel to allow cloud-based Building Management System to control parameters outlined as CONTROL in the points list. - Hood Control Panel to allow cloud-based Building Management System to implement SYSTEM ECONOMIZER control strategies for fully integrated Building Management. MONITORING AND CONTROL POINTS LIST SC PackagesDCV Packages Function Room Temperature(s) MONITOR Duct Temperature(s) MONITOR MUA DIscharge Temperature MONITOR Kitchen RTU Discharge Temperature MONITOR Controller Faults MONITOR Fan Faults MONITOR Fan Status MONITOR PCU Faults MONITOR PCU Filter Clog Percentages MONITOR Fire Condition MONITOR CORE Fire System MONITOR Building Pressures MONITOR Fans Button(s) MONITOR & CONTROL Lights Button(s) MONITOR & CONTROL Wash Button MONITOR & CONTROL Function Room Temperature MONITOR Duct Temperature(s) MONITOR MUA Discharge Temperature MONITOR Kitchen RTU Discharge Temperature MONITOR Fan Speed MONITOR Fan Amperage MONITOR Fan Power MONITOR VFD Faults MONITOR Controller Faults MONITOR Fan Faults MONITOR Fan Status MONITOR PCU Faults MONITOR PCU Filter Clog Percentages MONITOR Fire Condition MONITOR CORE Fire System MONITOR Building Pressures MONITOR Prep Time Button MONITOR & CONTROL Fans Button MONITOR & CONTROL Lights Button MONITOR & CONTROL Wash Button MONITOR & CONTROL Field Connection Antennas Wired OR Paddle Field Connection to Router OR Ethernet switch Connection for Modbus Factory wired OR Field Wired Terminal Blocks for wired connection Cellular Module Compute module DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 8293651 St. Paul's Lutheran - 10 Ft O... SC-310110MA 10/16/2025 INSTALL ECP #1-1 3 Phase w/ control for 1 Exhaust Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. BREAKER PANEL TO PRIMARY CONTROL PANEL Responsibility: Electrician BREAKER PANEL PRIMARY CONTROL PANEL BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED BREAKER 1PH CONTROL POWER. DO NOT WIRE TO GFCI OR SHUNT TRIP BREAKER. Hot Neutral H1 N1 120 V 15 A Ground GND 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL POWER. SWITCH #1 BREAKER 1PH WIRE TO VFD QUICK CONNECTOR MCA: MOCP: LINE LINE 208 V EF-1 SM-1 GND L1 L2 Ground 21.4 A 30 A CONTROL PANEL TO FANS Responsibility: Electrician PRIMARY PANEL FANS Load Wiring WIRE TO VFD QUICK WIRE TO DISCONNECT CONNECTOR MUST HAVE ITS OWN CONDUIT DO NOT SHARE CONDUIT! FLA: HP: VOLT: EF-101 LOAD LEG 1 LOAD LEG 2 GND GROUND FAN: SM-1 LOAD LEG 3 U1 V1 W1 8.3 2.000 208 V CONTROL PANEL TO ACCESSORY ITEMS Responsibility: Electrician CONTROL PANEL COMPONENT ALL SWITCHES FACTORY WIRED CAT-5 CONNECTION CONTROL PANEL SWITCHES TO J4 CONTROL PANEL HOOD LIGHTS TO 1400 W MAX WIRE TO J-BOX ON TOP OF HOOD B1 W1 GND BLACK WHITE GREEN HOOD LIGHTS 1 WIRE DIRECTLY TO COMMUNICATION ROUTER COMM MODULE. NET REQUIRES 1) DHCP 2) UDP PORT 1444 & 1445 OPEN FOR CAT-5 ETHERNET CONNECTION CONTROL PANEL WORLD WIDE TO WEB OUTBOUND TRAFFIC ONLY. -- WIRE TO CONTROL BOARD. INSTALL SENSOR IN ROOM AWAY FROM HEAT SOURCES. DO NOT INSTALL SENSOR CONTROL PANEL ROOM TEMP TO SENSOR ON THE CEILING GRID, SEE MANUAL. GROUPS: T1A T1B ROOM TEMP FACTORY WIRED TEMPERATURE SENSOR. MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T2A T2B HOOD 2 CAPTURE 1 WIRE TO CONTROL BOARD. SENSOR MOUNTED IN HOOD CAPTURE CONTROL PANEL CAPTURE VOLUME TO SENSOR VOLUME. T3A T3B HOOD 1 CAPTURE 1 CONTROL PANEL GAS VALVE TO 120V ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. GAS N1 HOT TO GAS VALVE NEUTRAL GAS SOLENOID THE FOLLOWING CONNECTIONS MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE SPECIFICATIONS CONTROL PANEL EXTERNAL SIGNAL FOR SHUNT TRIP ST TERMINAL IS ENERGIZED IN FIRE CONDITION. CONTROL PANEL EXTERNAL SIGNAL FOR CONTACTOR COIL KS TERMINAL IS DE-ENERGIZED IN FIRE CONDITION. ST N1 NEUTRAL FROM SHUNT COIL HOT TO SHUNT COIL SHUNT COIL KS N1 NEUTRAL_TO_CONTACTOR_COIL HOT_TO_CONTACTOR_COIL CONTACTOR_COIL CONT_RATED SPARE CONTACTS WILL MAKE CONTROL PANEL ON/OFF WITH DRY CONTACT SUPPLY FAN COMMON TO NORMALLY OPEN WHEN SUPPLY FAN IS ON. GROUP 1 SFC1 SFO1 COMMON NORMALLY OPEN SFC2 SFO2 COMMON NORMALLY OPEN CONTROL PANEL EXTERNAL TO SWITCH SIGNAL SWITCH THROUGH BMS WILL ACTIVATE ZONE1 FANS AND LIGHTS H1 IO1 BMS SWITCH C NO CONTROL PANEL GAS VALVE TO 24V DC ONLY ONLY ENERGIZED THROUGH LCD HMI WHEN FIRE SYSTEM ARMED. (NOT NEEDED IF USING 120V GAS VALVE). LGV N1D POSITIVE TO GAS VALVE NEGATIVE GAS SOLENOID CONTROL PANEL TO FIRE SYSTEM Responsibility: ALARM CONTRACTOR CONTROL PANEL COMPONENT CONTROL PANEL BUILDING SIGNAL FOR FIRE ALARM PANEL AL1 AL2 J9 BUILDING ALARM PANEL FIRE INPUT WIRE DIRECTLY TO CORE CIRCUIT BOARD. AL1 WILL MAKE AL2 IN FIRE CONDITION. CONTROL PANEL BUILDING SIGNAL FOR TROUBLE TROUBLE RELAY CONTACTS WILL MAKE TBC TO TBL IN TROUBLE CONDITION. BUILDING ALARM PANEL ALARM TBC TBL COMMON NORMALLY CLOSED CONTROL PANEL TO FIRE SYSTEM Responsibility: CERTIFIED INSTALLER CONTROL PANEL COMPONENT FIRE STAT SUPERVISED LOOP May be mixed factory and field wiring. See Installation Schematic. Multiple fire sensors possible. HIGH TEMP WIRE (842 F), PN: SLPCON-xFT required for all Supervised Loop wiring in contact with a hood. All other wiring shall be PN: 6320UL, Belden or similar. 21 22 23 24 FS-01 BK WH Fire Stat FS-02 BK WH Fire Stat CONTROL PANEL MOUNTED FIRE TO DUCT DETECTION STAT(S) FIRE STATS CONTROL PANEL SYSTEM PULL TO FIRE STATION MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM LOOP. Multiple manual actuation possible. Multiple manual actuation possible. A Plug jumper with wires from pin1 to pin4 and from pin2 to pin3 is mounted on J10, remove the jumpers and wire in the supervised actuation loop. Microswitch MS-01 is optional for fire system interlock. Auxiliary Interlock (AUX-01): Wire AU1 / AU2 of adjacent Master FS panel(s) in each manual activation loop for simultaneous activation. See Fire system drawings for more information. 101 102 103 104 AUX-01 AU1 AU2 PULL STATION MS-01 C NO Micro SW MAD-01 C NO Manual Actuation Device Adjacent FS Panel CAT-5 CONNECTION CONTROL PANEL MASTER FS TO BOARD. PLACE END OF LINE PLUG EOL120A IN EMPTY JACK. PN: EOL120A CORE PCB ADDITIONAL DEVICES MAY BE INLINE. ECPM03 UNLESS VFD, PCU, OR OTHER COMPONENT IN SERIES. J3 J5 J6 DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 8293651 St. Paul's Lutheran - 10 Ft O... SC-310110MA 10/16/2025 INSTALL ECP #1-2 3 Phase w/ control for 1 Exhaust Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. CONTROL PANEL MASTER FS TO PANEL WIRE TO LIKE TERMINALS IN ALL CORE PANELS THAT MUST ACTIVATE TOGETHER. SET MASTER & SLAVE DIP SWITCHES PER FIRE SYSTEM SHIELDED TWISTED PAIR INTERLOCK NETWORK MASTER CORE MANUAL. CA CB CC BLACK RED SHIELD CA CB CC TANK PROTECTION ELECTRICAL DETAIL 02/10/2021 Rev. 2 ELECTRICIAN: 1. WIRE MAIN CONTROL PANEL PER INCLUDED SCHEMATIC 2. WIRE ALL FANS PER INCLUDED SCHEMATIC 3. WIRE SHUNT TRIP BREAKER (OPTIONAL) 4. WIRE UDS APPLIANCE KILL SWITCH, IF EQUIPPED (OPTIONAL) 5. WIRE GAS VALVE NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS EXHAUST HOOD 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN GASELECTRIC ELECTRICAL CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION IN DEVICE VOLTAGE AMPERAGE COMMENTS SHUNT TRIP BREAKER (OPTIONAL)ST & N1 BREAKER COIL (A1 & A2) 120 VAC < 4 AMPS ST TO A1 ON SHUNT BREAKER COIL, AND NEUTRAL TO A2 ON SHUNT TRIP BREAKER COIL CONTROL PANEL POWER H1 & N1 + GROUND CIRCUIT BREAKER 120 VAC 15 AMPS CONTROL PANEL POWER MUST NOT BE RUN THROUGH SHUNT TRIP BREAKER UDS APPLIANCE KILL SWITCH (OPTIONAL)KTS & N1 KTS & N1 120 VAC < 4 AMPS KILL SWITCH TERMINALS MUST BE IN SERIES WITH OTHER KILL SWITCHES REMOTE 120VAC ANSUL AUTOMAN (OPTIONAL)AU1, AU2 SOLENOID 120 VAC < 6 AMPS 120V TO AU1, AU2 TO ANSUL ELECTRIC AUTOMAN, ANSUL SOLENOID TO NEUTRAL GAS VALVE LGV & N1D (IF 24 VDC) GAS & N1 (IF 120 VAC) RED/RED/GREEN 24 VDC OR 120 VAC < 1.0 AMPS IF 24 VDC - 2 WIRES & GROUND, N1D TO RED, LGV TO RED, AND GREEN TO GROUND IF 120 VAC - 2 WIRES & GROUND GAS TO RED, N1 TO RED, AND GREEN TO GROUND SHUNT TRIP BREAKER (OPTIONAL) -2 WIRES, 120VAC -ST TO A1 ON SHUNT BREAKER -NEUTRAL TO A2 ON SHUNT TRIP BREAKER POWER TO ELECTRIC APPLIANCE CONTROL PANEL POWER -2 WIRES & GROUND -120 VAC, 15 AMP SERVICE -WIRE TO H1 AND N1, GROUND -POWER MUST NOT ORIGINATE FROM SHUNT TRIP BREAKER GAS VALVE POWER -2 WIRES & GROUND -24 VDC WIRE TO LGV & N1D -120 VAC WIRE TO GAS &N1 GAS VALVE -STRAINER MUST BE INSTALLED UPSTREAM OF VALVE COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 8293651 St. Paul's Lutheran - 10 Ft O... SC-310110MA 10/16/2025 INSTALL ECP #1-3 Fire System #1 TANK FS - 4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. Installed in Hood Utility Cabinet with integral hood prewire panel. FS-1: MASTER TANK PROTECTION LOW-VOLTAGE DETAIL ALARM CONTRACTOR: 1. WIRE MANUAL ACTUATION DEVICE(S), *REMOTE FIRESTAT(S), CORE INTERLOCK(S), FIRE SENSOR(S) AND FIRE ALARM CONTACTS 2. COMPLETE FINAL HOOKUP OF SYSTEM 3. VERIFY FINAL FIRE SYSTEM TEST ATTENTION: LOW-VOLTAGE DC OR SIGNALING WIRE SHOULD BE ROUTED IN SEPARATE CONDUIT FROM ALL AC SOURCES 36 INCHES CLEARANCE REQUIRED IN FRONT OF ALL UTILITY CABINET DOORS THE PANEL SHALL ALSO BE LOCATED IN AN ACCESSIBLE AREA WHERE THE AUDIBLE AND VISUAL ALARMS CAN BE HEARD AND SEEN ELECTRIC GAS NOTE: SEE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR FURTHER INSTRUCTIONS ALARM CONTRACTOR REQUIREMENT ITEM CONNECTION IN PANEL CONNECTION ON DEVICE VOLTAGE AMPERAGE COMMENTS MANUAL ACTUATION DEVICE(S) 101 AND 104 102 AND 103 1 & 2 24 VDC < 1.0 AMPS WIRE MANUAL ACTUATION DEVICE TERMINAL 1 BETWEEN CORE PANEL TERMINALS 102 AND 103 WIRE MANUAL ACTUATION DEVICE TERMINAL 2 BETWEEN CORE PANEL TERMINALS 101 AND 104 JUMPER 101 TO 104 AND 102 TO 103 IF NO MANUAL ACTUATION DEVICE IS INSTALLED MANUAL ACTUATION DEVICE COVER N/A N/A N/A N/A MANUAL ACTUATION DEVICE COVER MUST BE INSTALLED IF SURFACE MOUNTED, USE COVER EXTENSION STI-6531B REMOTE FIRESTAT SENSOR(S) 21 AND 24 22 AND 23 BLACK AND WHITE 24 VDC < 1.0 AMPS WIRE FIRE SENSOR WHITE WIRES BETWEEN HOOD CORE PANEL TERMINALS 22 AND 23 WIRE FIRE SENSOR BLACK WIRE BETWEEN HOOD CORE PANEL TERMINALS 21 AND 24 OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE; SEE FIGURE 1 FIRE ALARM CONTACT AL1, AL2 VARIES 50V MAX (AC/DC) UP TO 1 AMP FIRE ALARM RELAY CONTACTS FOR BUILDING FIRE ALARM LOCATED IN THE CORE ELECTRICAL CONTROL PANEL CORE INTERLOCK(S) RS-485 COMMUNICATIONS SIGNAL TROUBLE CONTACT TBC, TBL, TOK VARIES MAX 120 VAC UP TO 6 AMPS WIRE TO TBL & TBC NORMALLY OPEN CONTACT, CLOSES IN TROUBLE CONDITION CORE COMMUNICATIONS CABLE RJ-45 Jack INTERNET CONNECTION SIGNAL <1.0 AMPS TYPICAL CONNECTION CAT5 CABLE TO LOCAL AREA NETWORK VIA ETHERNET SWITCH OR WIRELESS ROUTER WITH VALID INTERNET CONNECTION 42 TO 48 INCHES ABOVE FLOOR LEVEL TO CENTER OF PUSH STATION MANUAL ACTUATION DEVICE 10 TO 20 FEET FROM HOOD LOCATED NEAR POINT OF EGRESS FROM HOOD MANUAL ACTUATION DEVICE WIRES -4 WIRES, 24VDC WIRE (TERMINAL 1) BETWEEN 102 AND 103 -WIRE (TERMINAL 2) BETWEEN 101 AND 104 -ADDITIONAL PULL STATIONS WIRED IN SUPERVISED LOOP -USE BELDEN #6320UL OR SIMILAR WIRE MANUAL ACTUATION DEVICE PROTECTIVE COVER MUST BE INSTALLED SUPERVISED LOOP -4 WIRES, 24VDC CONNECT BLACK WIRES BETWEEN 21 AND 24 IN PANEL, CONNECT WHITE (OR RED) WIRES BETWEEN 22 AND 23 IN PANEL -ADDITIONAL FIRESTATS, WIRED IN SUPERVISED LOOP -USE HIGH TEMP (842°F) RAN OVER TOP OF HOOD; OTHERWISE BELDEN #6320UL OR SIMILAR PLENUM RATED WIRE -SEE FIGURE 1 CORE COMMUNICATIONS CABLE -CAT5 CABLE MUST BE INSTALLED TO A LOCAL AREA NETWORK WITH VALID INTERNET ACCESS VIA ETHERNET SWITCH OR WIRELESS ROUTER CORE INTERLOCK -2 WIRES + SHIELD -USE BELDEN#88760 OR SIMILAR WIRE -SEE FIGURE 3 FIRE ALARM PANEL FIRE ALARM CONTACT -2 WIRES WIRED TO NORMALLY OPEN CONTACTS (CLOSES IN FIRE CONDITION) -CORE CONTROL PANEL AL1 AND AL2 -SEE FIGURE 2 TROUBLE CONTACT -2 WIRES TO NORMALLY OPEN CONTACTS (CLOSE IN TROUBLE CONDITION) -CORE PANEL TERMINALS TBL AND TBC -SEE FIGURE 4 COOKING APPLIANCE(S) DESCRIPTION OF OPERATION: 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 10/01/2023 Rev. 3 EXHAUST HOOD HIGH TEMP (842°F) #441601C6.FE9 (WHT) & #441601C6.FE0 (BLK)WIRE OR SIMILAR ONLY IF RAN CA, CB, CC CA, CB, CC CORE SYSTEM (1) CA, TO CORE SYSTEM (2) CA. CORE SYSTEM (1) CB, TO CORE SYSTEM (2) CB. CORE SYSTEM (1) CC, TO CORE SYSTEM (2) CC. USE BELDEN# 88760 OR SIMILAR WIRE -SEE FIGURE 1A PART #SS2031ZA-EN #441601C6.FE9 (WHT) & #441601C6.FE0 (BLK)WIRE ONLY IF *REMOTE FIRESTAT(S) MAYBE BE REQUIRED DEPENDING ON THE DUCT LAYOUT AND HOOD TEMPERATURE RATING. REFERENCE MANUAL FOR LOCATION AND GUIDELINES. JOB NO JOB NAME MODEL NUMBER DATE DRAWN BY DWG NO SCHEMATIC TYPE 8293651 St. Paul's Lutheran - 10 Ft O... SC-310110MA 10/16/2025 INSTALL ECP #1-4 Fire System #1 TANK FS - 4.0/4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. Installed in Hood Utility Cabinet with integral hood prewire panel. FS-1: MASTER SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 8293651 MASTER DRAWING perry.hosm 5 10/16/2025 St . P a u l ' s L u t h e r a n - 1 0 F t O p t i o n 3/4" = 1'-0" 14 9 L a k e A v e , Up s t a t e N e w Y o r k 34 9 W C o m m e r c i a l S t . , S u i t e # 1 9 0 0 , E a s t R o c h e s t e r , N Y , 1 4 4 4 5 P H O N E : ( 5 8 5 ) 3 4 8 - 9 1 1 8 F A X : 9 1 9 - 2 2 7 - 5 9 2 7 E M A I L : r e g 5 4 @ c a p t i v e a i r e . c o m SA R A T O G A S P R I N G S , N Y , 1 2 8 6 6 DUCTWORK #1 PARTS - JOB#8293651 TAG PART #CFM GPM ZONE COVEREDBY SP WEIGHT VELOCITY QTY DESCRIPTION P1 DW1416ADP13 1350 -0.0140 7.53 1263 1 SINGLE WALL DUCT ADAPTER, 14" DUCT DIA TO 16" DUCT DIA, ASSEMBLY - 430 STAINLESS STEEL. P2 DW16TEASY 2250 1 -0.2571 19.23 1611 1 SINGLE WALL DUCT TEE, 16" DUCT, ASSEMBLY. P3 DW1016ADPEC21 900 -0.0598 10.99 1650 1 SINGLE WALL DUCT ECCENTRIC ADAPTER, 10" DUCT DIA TO 16" DUCT DIA, ASSEMBLY - 430 STAINLESS STEEL. P4 DW1011LT 900 -0.0062 3.90 1650 1 SINGLE WALL DUCT 10" DIAMETER, 11" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. P5 DW1024AJDKIT 900 -0.0084 10.09 1650 1 SINGLE WALL DUCT ADJUSTABLE, 10" DIAMETER, 23.5" LONG, FLANGE AT ONE END WITH A 10" ADJUSTABLE COLLAR - STAINLESS STEEL. P6 DW10SUBRASY 2.54 1 DUCT SUPPORT BRACKET KIT, 10" DUCT, USED FOR HANGING DUCT. 12 GA STEEL, CLEAR ZINC COATING. - 2 RINGS, 4 BRACKETS, & HARDWARE BAG 2. P7 DW10SUBRASY 2.54 1 DUCT SUPPORT BRACKET KIT, 10" DUCT, USED FOR HANGING DUCT. 12 GA STEEL, CLEAR ZINC COATING. - 2 RINGS, 4 BRACKETS, & HARDWARE BAG 2. P8 ASSEMBLED W/P11 DW10TEASY 900 1 -0.1248 10.16 1650 1 SINGLE WALL DUCT TEE, 10" DUCT, ASSEMBLY. P9 DW1007LT 900 -0.0040 2.60 1650 1 SINGLE WALL DUCT 10" DIAMETER, 7" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. P10 DW1012AJDKIT 900 -0.0034 5.82 1650 1 SINGLE WALL DUCT ADJUSTABLE, 10" DIAMETER, 11.5" LONG, FLANGE AT ONE END WITH A 10" ADJUSTABLE COLLAR - STAINLESS STEEL. P11 ASSEMBLED W/P8 O=S DW1011ADKIT 2.23 1 DUCT ACCESS DOOR WITH HANDLE & GREASE DAM, FOR 10" DUCT USE 11" DOOR. STAINLESS STEEL. P12 DW1629LT 2250 -0.0098 15.68 1611 1 SINGLE WALL DUCT 16" DIAMETER, 29" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. SYSTEM AT P12 -1.0306 0.00 P13 DW1604LT 2250 -0.0014 2.57 1611 1 SINGLE WALL DUCT 16" DIAMETER, 4" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. SYSTEM AT P13 -1.0306 0.00 P14 DW1630AJDKIT 2250 -0.0047 20.06 1611 1 SINGLE WALL DUCT ADJUSTABLE, 16" DIAMETER, 29.5" LONG, FLANGE AT ONE END WITH A 16" ADJUSTABLE COLLAR - STAINLESS STEEL. SYSTEM AT P14 -1.0306 0.00 P15 DW1635LT 18.67 1 SINGLE WALL DUCT 16" DIAMETER, 35" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. P16 DW1623LT 12.32 1 SINGLE WALL DUCT 16" DIAMETER, 23" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. P17 DW1648AJDKIT 30.39 1 SINGLE WALL DUCT ADJUSTABLE, 16" DIAMETER, 47.5" LONG, FLANGE AT ONE END WITH A 16" ADJUSTABLE COLLAR - STAINLESS STEEL. P18 DW1690ASY 13.00 1 SINGLE WALL DUCT 90 DEGREE ELBOW, 16" DUCT, ASSEMBLY. P19 ASSEMBLED W/P23 DW16TEASY 1 19.23 1 SINGLE WALL DUCT TEE, 16" DUCT, ASSEMBLY. P20 DW1645ASY 7.22 1 SINGLE WALL DUCT 45 DEGREE ELBOW, 16" DUCT, ASSEMBLY. P21 DW1645ASY 7.22 1 SINGLE WALL DUCT 45 DEGREE ELBOW, 16" DUCT, ASSEMBLY. P22 DW1620ADPEC17 12.01 1 SINGLE WALL DUCT ECCENTRIC ADAPTER, 16" DUCT DIA TO 20" DUCT DIA, ASSEMBLY - 430 STAINLESS STEEL. P23 ASSEMBLED W/P19 O=T DW1617ADKIT 4.59 1 DUCT ACCESS DOOR WITH HANDLE & GREASE DAM, FOR 16" DUCT USE 17" DOOR. STAINLESS STEEL. P24 DW2047LT 31.08 1 SINGLE WALL DUCT 20" DIAMETER, 47" LONG, FLANGE AT BOTH ENDS. STAINLESS STEEL. P25 DW2090ASY 18.41 1 SINGLE WALL DUCT 90 DEGREE ELBOW, 20" DUCT, ASSEMBLY. 3M-2000PLUS 0.80 8 DUCT - 3M FIRE BARRIER 2000 PLUS SILICONE - USED AS SEALANT TO SEAL DUCT JOINTS. DW10CLASY 0.82 7 DUCT "V" CLAMP WITH NEW DESIGN 14 GA BRACKETS, 10" DUCT, ASSEMBLY. DW14CLASY 1.06 1 DUCT "V" CLAMP WITH NEW DESIGN 14 GA BRACKETS, 14" DUCT, ASSEMBLY. DW16CLASY 1.18 15 DUCT "V" CLAMP WITH NEW DESIGN 14 GA BRACKETS, 16" DUCT, ASSEMBLY. DW20CLASY 1.41 4 DUCT "V" CLAMP WITH NEW DESIGN 14 GA BRACKETS, 20" DUCT, ASSEMBLY. TOTAL WEIGHT 326.62 TOTAL PRESSURE -3.5854 SINGLE WALL FACTORY BUILT DUCTWORK - FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL. - ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. DUCT DIAMETER 8" 10'10'24' 10" 10'10'24' 12" 10'10'24' 14" 10'10'24' 16" 10'10'24' 18" 10'10'24' 20" 10'10'24' 22" 10'10'24' 24" 10'10'24' HORIZONTAL SUPPORT (FT) VERTICAL WALL SUPPORT (FT) VERTICAL CURB SUPPORT (FT) 10'10'24' 10'10'24' 10'10'24' 5" 6" 7" 26" 28" 30" 32" 10'10'24' 34" 10'10'24' 36" 10'10'24' 10'10'24' 10'10'24' 10'10'24' - DUCTWORK SHALL SLOPE NOT LESS THAN 1/16" PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. - WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16" PER LINEAR FOOT. DO NOT LEAK TEST USING SMOKE BOMBS CONTAINING CHLORINES/CHLORIDES. CONSULT WITH CAPTIVEAIRE FOR PROPER LEAK TESTING METHODS. DW10SUBRASY - HORIZONTAL SUPPORT 12" SUPPORT SYSTEM DETAILS #1 SHEET NO. SCALE: DWG.#: DRAWN DATE: BY: REVISIONS DESCRIPTION ww w . c a p t i v e a i r e . c o m DATE: AC C O R D A N C E No . 9 6 BU I L T NF P A WI T H IN S LI D TE R C U S 8293651 MASTER DRAWING perry.hosm 6 10/16/2025 St . P a u l ' s L u t h e r a n - 1 0 F t O p t i o n 3/4" = 1'-0" 14 9 L a k e A v e , Up s t a t e N e w Y o r k 34 9 W C o m m e r c i a l S t . , S u i t e # 1 9 0 0 , E a s t R o c h e s t e r , N Y , 1 4 4 4 5 P H O N E : ( 5 8 5 ) 3 4 8 - 9 1 1 8 F A X : 9 1 9 - 2 2 7 - 5 9 2 7 E M A I L : r e g 5 4 @ c a p t i v e a i r e . c o m SA R A T O G A S P R I N G S , N Y , 1 2 8 6 6