Loading...
HomeMy WebLinkAbout20260004 632 Lake Ave Addition ApplicationBack of House - 632 Back of House - 632 Back of House - 632 Back of House - 632 Back of House - 632 Back of House - 632 Back of House - 632 Back of House – 632 looking at 4 Stafford Bridge Rd property (next door) Back of House – 632 looking at 4 Stafford Bridge Rd property (next door) Back of House – 632 Back of House – 632 looking at 636 Lake Ave property (next door) Back of House – 632 looking at 636 Lake Ave property (next door) Fron t of House – 632 looking at 4 Stafford Bridge Rd Property (next door) Front of House – 632 looking at Lake Ave Rd Front of House – 632 looking at 636 Lake Ave property (next door) Front of House – 632 looking at 636 Lake Ave property (next door) Front of House – 632 looking at 4 Stafford Bridge Rd property (next door) Front of House – 632 Front of House – 632 looking at 4 Stafford Bridge Rd property (next door) Co v e r S h e e t ADDITION AT: #632 Lake Ave Saratoga Springs, NY PLAN PAGE TABLE LABEL TITLE DESCRIPTION COMMENTS A-1 COVER SHEET A-2 NOTES A-3 EXISTING CONDITIONS AND SCOPE OF WORK A-4 FOUNDATION PLAN AND DETAILS A-5 FLOOR PLANS A-6 ROOF PLAN AND BUILDING SECTIONS A-7 ELEVATIONS A-8 TYPICAL WALL SECTION, DETAIL, SCHEDULES Location Map N.T.S. Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-1 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE ENERGY NOTES 1. TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT THE ATTACHED PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH CHAPTER 11 OF THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NEW YORK STATE. WINDOW NOTES 1. ANY REPLACEMENT WINDOWS SHALL BE A MINIMUM OF U=.30 WITH DOCUMENTATION PROVIDED TO THE BUILDING DEPARTMENT ALONG WITH THE SPECIFICATIONS FOR ANY NEW EQUIPMENT REPLACEMENT (HOT WATER HEATER, FURNACE ... ) RENOVATION NOTES 1. REPLACE ANY DAMAGED STRUCTURAL OR OTHER STRUCTURE COMPONENTS DISCOVERED DURING THE CONSTRUCTION PROCESS. FIRE, CARBON MONOXIDE AND SMOKE DETECTION NOTES 1.UNLESS OTHERWISE INDICATED ON THE DRAWINGS, HARD-WIRED SMOKE DETECTING DEVICES MUST BE INSTALLED IN EACH NEW SLEEPING ROOM, OUTSIDE ALL NEW SLEEPING AREAS, ON EACH STORY WITHOUT SLEEPING ROOMS, IN BASEMENTS WITH OR WITHOUT HABITABLE SPACE. NONE ARE REQUIRED IN UNINHABITABLE ATTICS. ALL DETECTORS IN NEW CONSTRUCTION MUST BE INTER-CONNECTED. 2.CARBON MONOXIDE ALARMS IN DWELLING UNITS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. WHERE A FUEL-BURNING APPLIANCE IS LOCATED WITHIN A BEDROOM OR ITS ATTACHED BEDROOM, A CARBON MONOXIDE ALARM SHALL BE INSTALLED WITHIN THE BEDROOM. 3.SMOKE AND CARBON MONOXIDE ALARMS MUST BE PROVIDED WITH BATTERY BACKUP, EITHER INTERNAL OR REMOTE. 4.HARD-WIRE DETECTING DEVICES MUST BE POWERED FROM A LIGHTING CIRCUIT WITH NO INTERVENING SWITCHES. ELECTRONIC, LOW-VOLTAGE SYSTEMS ARE ALLOWED PROVIDED THE SYSTEM COMPLIES WITH NFPA 72 PLUMBING, HEATING VENTILATING AND AIR CONDITIONING SYSTEMS 1.ALL HVAC WORK, EQUIPMENT, ETC. SHALL BE IN ACCORDANCE WITH THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NYS. 2.THE HVAC CONTRACTOR SHALL CONDUCT ALL TESTS AND INSPECTIONS OF HIS WORK AS REQUIRED BY THE OWNER AND LOCAL ENFORCEMENT AUTHORITY. 3. THE HVAC CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF ALL OTHER TRADES. 4. ALL WORK SHALL BE PERFORMED BY MECHANICS SKILLED IN THIS MECHANICAL TRADE. 5. THE CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING. ALL CONTROL WIRING SHALL BE CONCEALED FROM VIEW. 6. THE CONTRACTOR SHALL PROVIDE OPERATING AND MAINTENANCE INSTRUCTIONS ON ALL EQUIPMENT TO THE OWNER. INFORMATION SHALL BE BOUND NEATLY AND IN A COMPREHENSIBLE MANNER. 7. PROVIDE FIREPLACE WHERE INDICATED WITH FRESH AIR INTAKE, GLASS DOORS, FIREPROOF FLUE, SPARK ARRESTOR, REQUIRED FLASHING, AND PARTS REQUIRED AS NECESSARY FOR A COMPLETE INSTALLATION. MODEL AS SELECTED BY OWNER IF APPLICABLE. 8. BATHROOM AND DRYER EXHAUST TO VENT TO EXTERIOR PER CODE. 9. THE CONTRACTOR AND THE OWNER SHALL BE RESPONSIBLE FOR THE SPECIFICATION OF ALL HEATING AND VENTILATING EQUIPMENT NOT SPECIFICALLY NOTED ON THESE DRAWINGS. THE HEATING CONTRACTOR SHALL SUBMIT CATALOG CUTS ON ALL HEATING EQUIPMENT AND MATERIALS TO THE OWNER AND/OR GENERAL CONTRACTOR FOR APPROVAL. 10. ALL NEW SPACES SHALL BE PROVIDED WITH EQUIPMENT CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF AT LEAST 68 DEGREES AT A POINT 3 FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS. 11. PROGRAMMABLE THERMOSTATS SHALL BE PROVIDED. 12. PLUMBING CONTRACTOR SHALL COMPLY WITH THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NEW YOUR STATE FOR THE DESIGN AND INSTALLATION OF ALL PLUMBING SYSTEM COMPONENTS. ALL WORK SHALL BE INSPECTED AS REQUIRED DURING CONSTRUCTION AND APPROVED AT THE END OF THE PROJECT BY THE LOCAL ENFORCEMENT AUTHORITY. No t e s STRUCTURAL NOTES 1. ALL STRUCTURAL DESIGN ELEMENTS AND COMPONENTS ARE DERIVED FROM APPLICABLE PROVISIONS OF THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NEW YORK STATE UNLESS OTHERWISE NOTED ON THE DRAWINGS. WHERE NOTED, CERTAIN STRUCTURAL MEMBERS MAY BE DESIGNED USING: -THE AMERICAN FOREST AND PAPER ASSOCIATION (AF&PA) NATIONAL DESIGN SPECIFICATIONS (NDS) -MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ASCE 7) 2. NO GEOTECHNICAL EVALUATION HAS BEEN DONE IN CONNECTION WITH THE FOUNDATION DESIGN. IN ACCORDANCE WITH TABLE R401.4.1 THE LOAD BEARING PRESSURE USED FOR DESIGN OF ALL FOUNDATION SUPPORTING ELEMENTS IS 2500 PSF FOR SAND , SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL. IF OTHER SOIL TYPES ARE ENCOUNTERED IN EXCAVATION OR IF THE ACTUAL SOIL BEARING PRESSURE IS QUESTIONABLE, CONSULT WITH ARCHITECT /ENGINEER 3. IT IS NOT ANTICIPATED THAT GROUND WATER WILL BE ENCOUNTERED IN EXCAVATIONS. FOOTINGS SHALL NOT BE POURED WITHIN SEASONAL HIGH GROUND WATER ZONES. CONSULT ARCHITECT/ENGINEER IF HIGH GROUND WATER IS ENCOUNTERED STRUCTURAL DESIGN LOADS: LIVE LOADS SLEEPING ROOMS .................... 30 PSF NON-SLEEPING ROOMS ........... 40 PSF EXTERIOR DECKS ..................... 40 PSF EXTERIOR BALCONIES .............40 PSF HABITABLE ATTIC .................... 30 PSF ATTIC WITHOUT STORAGE .....10 PSF GROUND SNOW LOAD ............ 50 PSF FRAMING NOTES 1. ALL WINDOW DOOR HEADERS TO BE TWO (2) 2x1 O'S UNLESS OTHERWISE NOTED (SEE FRAMING PLANS). ALL HEADERS IN OPENINGS 72" OR MORE MUST BE SUPPORTED BY DOUBLE JACK STUDS. 2. ALL FRAMING TO BE 8" MINIUMUM ABOVE FINISHED GRADE. 3. ALL FRAMING TO BE FASTENED IN ACCORDANCE WITH TABLE R602.3(1) OF THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NYS. 4. ALL EXTERIOR WALLS TO BE 2x6 @ 16" O.C. WITH R-21 FIBERGLASS BATT INSULATION UNLESS OTHERWISE NOTED. ALL INTERIOR PARTITIONS TO BE 2x4 @ 16" O.C. UNLESS NOTED OTHERWISE. 5. INSTALL METAL OR WOOD BRIDGING AT THE MIDPOINT OF ALL JOIST SPANS EXCEPT WHERE NOTED. NOT REQUIRED WITH ENGINEERED JOISTS. 6. PROVIDE DOUBLE FRAMING AROUND ALL FLOOR OPENINGS AND UNDER ALL BEARING PARTITIONS PARALLEL WITH JOIST DIRECTION. MODIFY FLOOR FRAMING AS REQUIRED TO ACCOMMODATE PLUMBING AND MECHANICAL REQUIREMENTS WITHOUT AFFECTING STRUCTURAL INTEGRITY. 7. INSPECT ALL LUMBER FOR DEFECTS BEFORE INSTALLING . DISCARD ANY SUCH LUMBER. ALL RAFTERS AND FLOOR JOISTS TO BE INSTALLED WITH CROWN UP. 8. ALL FRAMING STUDS TO BE #2 CONSTRUCTION GRADE UNLESS NOTED OTHERWISE. RAFTERS AND JOISTS TO BE SPF NO. 2 OR BETTER. DO NOT CHANGE SIZE OR SPACING OF ANY STRUCTURAL ELEMENTS WITHOUT ENGINEER'S WRITTEN CONSENT. fb=1, 150psi. E=1,400,000 psi (FOR REPETITIVE USE MEMBERS) 9. PROVIDE CONCEALED WOOD BLOCKING IN ALL WALLS THAT REQUIRE SURFACE MOUNTED ITEMS SUCH AS: CABINETRY, HOSE BIBS, FIREPLACE MANTELS, MOLDING, RAILINGS, TOWEL BARS, ETC. 10. PROVIDE FIRESTOPPING WHERE REQUIRED BY THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NEW YORK STATE. 11. ALL DIMENSIONS ARE TAKEN TO ROUGH FRAMING UNLESS OTHERWISE NOTED. 12. ROOF TRUSSES TO BE CERTIFIED BY TRUSS MANUFACTURER. CONTRACTOR TO COORDINATE AND CONSULT WITH ARCHITECT /ENGINEER PRIOR TO TRUSS FABRICATION IF TRUSSES ARE TO BE USED IN FRAMING. 13. 1.9E MICRO-LAM LUMBER DESIGN STRESS - E+1,900,000 psi, fb = 2,600 psi. CONSTRUCTION DOCUMENTS 1 THE ARCHITECT /ENGINEER HAS NOT BEEN RETAINED FOR CONSTRUCTION OBSERVATION OR ADMINISTRATION AND ASSUMES NO RESPONSIBILITY FOR FIELD CHANGES, CONTRACTOR METHODS, MATERIAL SELECTIONS, PRODUCT PERFORMANCE OR WARRANTY OR SAFETY DURING CONSTRUCTION. 2 LAW DOES NOT PERMIT ALTERATIONS TO THESE DOCUMENTS. THE ARCHITECT / ENGINEER MUST APPROVE ANY ALTERATIONS TO THE DRAWINGS. ABSENT SUCH APPROVAL, THE ARCHITECT /ENGINEER IS NOT RESPONSIBLE FOR SUBSTANTIVE CHANGES. 3 THESE PLANS ARE INSTRUMENTS OF SERVICE FOR THE CONSTRUCTION OF ONE BUILDING ONLY AND ARE NOT TO BE COPIED IN ANY FORM WHATSOEVER WITHOUT THE EXPRESS WRITTEN CONSENT OF ARCHITECT /ENGINEER. 4 THE PLANS ARE NOT VALID FOR USE IN OBTAINING A BUILDING PERMIT WITHOUT THE APPLICATION OF THE ORIGINAL "SEAL" AND SIGNATURE OF THE ARCHITECT/ ENGINEER 5. THESE DOCUMENTS WERE PREPARED FOR THE CONSTRUCTION OF A SINGLE PROJECT. ANY UNAUTHORIZED USE OF THESE DOCUMENTS IS EXPRESSLY PROHIBITED AND CONSTITUTES THEFT OF SERVICES. GENERAL NOTES 1.ALL GENERAL NOTES ON THIS SHEET APPLY TO ALL DRAWINGS. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS AND SEQUENCING AND SHALL BE RESPONSIBLE TO THE OWNER FOR PROVIDING A SAFE WORK ENVIRONMENT DURING THE CONSTRUCTION PERIOD. 3.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ALL TEMPORARY SUPPORTS. BRACE BUILDING UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. 4. THIS BUILDING HAS BEEN DESIGNED IN COMPLIANCE WITH THE REQUIREMENTS OF THE CURRENT RESIDENTIAL ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE AND THE RESIDENTIAL CONSTRUCTION CODE OF NEW YORK STATE. APPLICABLE CODE IS IRC 2020 VERSION AS ADOPTED BY NYS. 5. ALL MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTION AND RECOMMENDATIONS. THE CONTRACTOR SHALL DELIVER TO THE OWNER ALL MANUFACTURER'S WARRANTIES, GUARANTEES, LITERATURE AND OPERATING INSTRUCTIONS FOR ALL PRODUCTS AND EQUIPMENT. 6. DIMENSIONS AND DETAILS ARE BASED ON THE BEST AVAILABLE INFORMATION AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFING FIELD DIMENSIONS BEFORE ORDERING MATERIALS AND PREFABRICATED ITEMS. 7. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS AND COMPONENTS OF NON-SPECIFIED ITEMS, SUCH AS: NAILS, FLASHING, ETC. TO PROVIDE A COMPLETE CONSTRUCTION PROJECT, SOUND AND WEATHER TIGHT AND TO COMPLY WITH CURRENT STANDARDS OF QUALITY CONSTRUCTION. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING HIS OWN WORKMANSHIP TO THE EXTENT THAT SATISFIES THE OWNER. 9. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY MECHANICS SKILLED IN THEIR RESPECTIVE TRADES. 10. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD AND REPORT ALL DISCREPANCIES TO THE ARCHITECT/ENGINEER FOR RESOLUTION. 11. OWNER AND BUILDER SHALL COMPLY WITH THE LAWS , STATUTES AND RULES THAT GOVERN CONSTRUCTION OF THIS RESIDENCE. 12. ALL MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR, INCLUDING BUT NOT LIMITED TO SHORING, SUPPORT AND BRACING OF EXISTING STRUCTURES AS REQUIRED FOR THE WORK. CONSULT WITH THE ARCHITECT / ENGINEER WHERE NECESSARY. 13. COORDINATE SELECTION OF ALL MATERIALS AND PRODUCTS NOT SPECIFICALLY CALLED OUT IN THE SPECIFICATIONS AND ON THE DRAWINGS SUCH AS: PAINTING MATERIALS AND COLORS, INTERIOR FINISHES, LIGHT FIXTURES, CABINETRY, APPLIANCES AND ACCESSORIES, WITH THE OWNER. 14. THE CONTRACTOR SHALL PROVIDE A ONE-YEAR GUARANTEE OF MATERIALS AND WORKMANSHIP FOR ALL WORK UNDERTAKEN, COMMENCING AT SUBSTANTIAL COMPLETION. THE WORK IS ALSO SUBJECT TO APPLICABLE PROVISIONS OF THE HOME WARRANTY ACT OF NEW YORK STATE. ELECTRICAL NOTES 1.ALL WORK SHALL COMPLY WITH THE 2020 INTERNATIONAL RESIDENTIAL CODE AS ADOPTED BY NEW YORK STATE. 2.THE ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF ALL TRADES AND ALL WORK SHALL BE PERFORMED BY MECHANICS SKILLED IN THE ELECTRICAL TRADE. 3.ALL WIRING SHALL BE CONCEALED ABOVE CEILINGS OR WITHIN WALLS UNLESS NOTED OTHERWISE. ALL EXPOSED WIRING SHALL BE LOCATED SO THAT IT IS OUT OF VIEW AS MUCH AS POSSIBLE. ALL EXPOSED CONDUIT SHALL BE DONE IN THE NEATEST AND MOST ORDERLY FASHION. 4.HVAC EQUIPMENT SHALL BE BY OTHERS. COORDINATE WITH HEATING AND PLUMBING CONTRACTORS AND PROVIDE ALL LINE VOLTAGE WIRING AND CONNECTIONS TO THEIR EQUIPMENT AS REQUIRED. 5.GROUND FAULT RECEPTACLES MUST BE PROVIDED PER RESIDENTIAL CODE OF NEW YORK STATE. 6.AFCI RECEPTACLES SHALL BE PROVIDED IN ALL BEDROOMS. 7.MINIMUM OF 75% OF PERMAN EN TL Y INSTALLED LIGHT FIXTURES SHALL BE RATED FOR ENERGY EFFICIENCY. (I.E.: CFL, LED, ETC.) Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-2 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE TermitesFrost Line DepthWeathering NOYES Saratoga = 0 None48"SevereC11550 Subject to Damage From. Winter Design Temp.Seismic Design Cat. Ice-Barrier Underlayment Req'd Ground Snow Load Wind Design Speed (mph) Topographic effects Special wind region Wind-borne debris zone AIR FREEZING INDEX MEAN ANNUAL TEMP Flood Hazards NO NO NO 1500 IRC 2020 - R301.2 (1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA 2020 International Residential Code as Adopted by NYS-REVIEW Occupancy : Single Family Dwelling Classification by Construction Type: Frame Construction Building Height: 25'-4"+/- Number of Stories: 2 Stories (Story ht of walls <11'-7") Minimum Ceiling Height: 7'-6" Special Kitchen Extinguishing System: Not Required Fire & Smoke Detection: Required ZONING INFORMATION Residential Use Sq Ft not including Garage: 1st floor = 609 Sq Ft DN Exist. Exist. Exist.Exist. Exist. Exist. Exist. Existing Exist Exist. Exist. Exist. Exist. Exist. Exist. Exist. Exist. Exist. Exist. Exist. Existing Wall to be removed Existing Wall to remain New partition Wall per plan LEGEND 4'-0" 4'-0"6'-0" 10" 161 SQ FT 64 SQ FT 255 SQ FT 429 SQ FT 44 SQ FT 124 SQ FT64 SQ FT 31 SQ FT MASTER BATH MASTER BDRMBEDROOM LAUNDRY BATHKITCHEN LIVING STAIRS Perimeter of New Addition Remove Existing Siding to Extents of Addition 3 A-3 3 A-3 3 A-3 3 A-3 Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-3 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE Existing 1st Floor 3/16"=1'-0" 1 A-3 1 A-3 2 A-3 2 A-3 Existing Conditions N.T.S. 3 A-3 3 A-3 3D Overlays Scope of Work N.T.S. Hatched Area to be Removed Ex i s t i n g C o n d i t i o n s an d S c o p e o f W o r k Existing House Shaded Area Proposed Addition Shaded Area Proposed Addition S S S S 20202020 UP J 20 '-0 " CL 8'-0" CLCL 9'-9" CL 10'-0 1/2" CL 9'-9" CL EQ. (9'-7" +/-) CL EQ. (9'-7" +/-)EQ. (9'-7" +/-) 2x10 Joists 16" OC Existing Foundation Walls 2-PT 2X12 Dropped Beam Install MGU 3.63-SDS Hanger for bearing at post PT 6x6 Posts, typ. 1 A-7 1 A-7 24" Bigfoot Concrete Pier Footing, typ. 2 PT 2x124 A-4 4 A-4 3 A-4 3 A-4 PT 2x10 Ledger Board Framing to Align with Foundation, typ. 2 A-7 2 A-7 3 A-7 3 A-7 Existing CMU Foundation 3 A-6 3 A-6 1 A-6 1 A-6 Typical Foundation Insul Above Ground Walls to be R-21 F.G. Blanket Wrap Insul. Full Ht Below Grade to be R-15 Rigid Insulation Fasten to PT Furring Strip top & Bottom TYP COLUMN & PAD FTG. 3" Adj Stl Col on 30X30X12" Conc. Ftg 4-#4 Rebar Each way BASEMENT SLAB NOTE: 4" POURED CONCRETE SLAB. (3,000 PSI MIN) R.O.B. GRAVEL OR CRUSHED STONE SUB-BASE 6 MIL POLY VAPOR BARRIER 8"X16" Pilaster w/ 4-#4 Bar vert (Center on Wall) New Foundation to be 8" Poured Concrete J (4) 2x12 Flush Beam 4' min. Crawl Space Drill into existing Found. wall and Install #4 Rebar Dowels @ 24" o.c. Fasten w/ Chem- Rex Epoxy Stud anchors or equal. Dowels to extend into new Fdn. Wall 16" Min. (Typ.) Create Pocket In New Poured Fdn Wall for PT Beam Bearing, typ. (4" Min. Bearing) 1a A-4 1a A-4 FLOOR FRAMING 2X10 SPF #1 or #2 @16" o.c. (Bridging @ mid-span)J1 A-6 1 A-6 3 A-6 3 A-6 (2) 24"x24" Openings to Crawl Space Field Located 2 A-8 2 A-8 5 A-4 5 A-4 Tongue & Groove Decking 2x10 Joist 3 - PT 2x12 PT 6X6 PT 6X6 UPPER 6X6 TO BEAR DIRECTLY ON BEAM CONNECT W/ HURRICANE CLIPS ABOVE AND BELOW Simpson Strong Tie BCS2-3/6 Cap / Base Tongue & Groove Decking 2x10 Joist 3 - PT 2x12 PT 6X6 PT 6X6 UPPER 6X6 TO BEAR DIRECTLY ON BEAM CONNECT W/ HURRICANE CLIPS ABOVE AND BELOW Simpson Strong Tie BCS2-3/6 Cap / BaseMGU3.63-SDS HangerMGU3.63-SDS Hanger Tongue and Groove Decking Hanger 2x10 Joist 2 - PT 2x12 Tongue and Groove Decking Hanger 2x10 Joist 2 - PT 2x12 1/2" Epoxy Dowels to Tie Walls Together New 8" Poured conc fdn Wall Existing CMU Foundation WallNew 8"x16" Poured Concrete Strip Footing w/ 2-#4 Rebar Continuous. Provide 24" long (min) #4 Dowels @ 24" o.c. Use caution during excavation as not to undermine existing footings. New Frost Wall Fill Cores of existing CMU Wall solid w/ Grout for rebar Anchor embedment Typical of all Foundation connection points. Caulk Joints between new Found. Wall and existing w/ Sika Concrete sealant or Equal. (Typ.) 1/2" Epoxy Dowels to Tie Walls Together New 8" Poured conc fdn Wall Existing CMU Foundation WallNew 8"x16" Poured Concrete Strip Footing w/ 2-#4 Rebar Continuous. Provide 24" long (min) #4 Dowels @ 24" o.c. Use caution during excavation as not to undermine existing footings. New Frost Wall Fill Cores of existing CMU Wall solid w/ Grout for rebar Anchor embedment Typical of all Foundation connection points. Caulk Joints between new Found. Wall and existing w/ Sika Concrete sealant or Equal. (Typ.) Flashing for water- tight connection Approved joist hangers LedgerLok 3 5/8" Hvy Duty Lag Screw by Fastenmaster or Eq. @ 8" o.c. Staggered PT 2x10 Joist w/ 5/4 Decking over 2X10 Rim Joist PT 2x10 Ledger Hold Bottom of ledger even with bottom of existing 2X10 Rim joist Wall Framing Existing CMU foundation DTT1Z by simpson Strong tie or eq. Provide in 4 Evenly spaced Locations per deck & one within 24" of ea end of ledger Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-4 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE Proposed Foundation 1/4"=1'-0" 1 A-4 1 A-4 Fo u n d a t i o n P l a n an d D e t a i l s Beam/Post Detail 3/4"=1'-0" 4 A-4 4 A-4 End Beam Detail 3/4"=1'-0" Deck Ledger Connection Detail 3/4"=1'-0" 5 A-4 5 A-4 Ledger Bolt Detail N.T.S. 2 A-4 2 A-4 3 A-4 3 A-4 FOUNDATION PLAN TYP NOTES 1)Columns - 3" Sch 40 Steel Adjustable Column by Tel-O-Post or Eq. STANDARD END PLATE: 4¼" x 7½" x .120" SWIVEL END PLATE: 4" x 6" x .120" 2)Pier Footings - 30"x30"x12" Poured concrete w/ 4-#4 Bar E.W. 3)Field Locate Sump Pit as necessary 4)Typ Found Walls - 8" thick (3,000 psi min) 1-#4 bar Horiz @ top & Mid-Point of wall & 12" Above Footing 5)Typ Strip Footings - 8"X16" w/ 2-#4 Bar Cont. (2,500 psi min) 6)Exposed Concrete Slabs-For Porches, carport slabs and steps exposed to the weather, and garage floor slabs, Concrete shall be 5-7 air-entrained and be a min of 3,500 psi. 7)Bottom of footings to be 48" below fin Grade min 8)Provide Anchor Bolts w/ nuts & Washers @ 6' o.c. and 12" from corners. Bolts to be placed in middle 1/3 of sill plate 9)Brace Foundation walls prior to backfill 10)Install Solid Blkg under all point loads to provide continuous support to Foundation. 11)Backfill with well-draining granular material (R.O.B. Gravel or Sand) 12)Basement Shall be provided with at least 1 Emergency Escape and rescue opening opening directly to the exterior per R310 13)FIRE PROTECTION OF FLOOR ASSEMBLY:Engineered Floor systems such as I-joists & pre-engineered Floor trusses shall be provided with a ½-inch gypsum wallboard, 5/8-inch wood structural panel, on the underside of the floor framing member. An accepted equivalent fire resistive coating on the framing members may also be used. Assumed On-site soil is sandy. Vert Foundation Wall Reinforcing #4 Bar @ 24" o.c. THIS PROJECT IS IN COMPLIANCE WITH THE 2020 NYSECC Connection Detail 1/4"=1'-0" 1a A-4 1a A-4 R404.1.2 (1) Minimum horizontal Reinforcement for Concrete Basement Walls* Max Unsupported Height of Basement Walls (feet)Location of Horizontal Reinforcement Less than or Eq to 8'1 - #4 Bar within 12" of the top of the wall & 1 - #4 bar near mid-height of the wall Over 8'1 - #4 Bar within 12" of the top of the wall & 1 - #4 bar near third points of the wall * 1 - #4 Bar 12" Above Footing DN W03W03 W03W03 W05W05W05W05 W02W02 W03W03 W05W05 W04W04 2668 2668 2668 2 6 6 8 5068 5068 5068 30X22 ATTIC ACCESS SD CO SD SD SD 10'-10" 6'-8 1/2" 30'-0" 12'-11"2'-1"2'-1"11'-1 1/2" 22'-4" CL 7'-6" CL 6'-10" CL 5'-0" CL 16'-6"8'-6" CL 5'-7" CL 8'-2" CL 6'-0" CL 6'-0" 11'-6 1/2" 5'-0"8'-4" 1'-8" 5'-7" 1'-8 1/2" 10'- 0" 2'-1" 8'-9" 1 4 0 ° 114 SQ FT 46 SQ FT 102 SQ FT 121 SQ FT122 SQ FT STAIRS BEDROOM 1 BEDROOM 2 BEDROOM 3 BATH 3 A-6 3 A-6 1 A-6 1 A-6 1 A-7 1 A-7 3 A-7 3 A-7 2 A-7 2 A-7 1 A-6 1 A-6 3 A-6 3 A-6 2 A-8 2 A-8 8' Ceilings in Second Floor SpacesDN 6068 Exist. Exist.Exist.6068 Exist. Exist. Exist. Exist. Exist. Exist. Exist. Exist. 6068 W01W01 W01W01 W01W01 W01W01W01W01 W01W01 W01W01 W01W01 UP Existing Wall to be removed Existing Wall to remain New partition Wall per plan LEGEND SD CO 30'-0" CL 8'-0" 20'-0" CL 5'-11 1/2"6'-1"5'-11" CL 6'-1"5'-11 1/2" CL 5'-6" CL 5'-6" CLCL 9'-9" CL 10'-0 1/2" CL 9'-9" CL 5'-5" CL 9'-6" CL 5'-1" CL 9'-6" CL 8'-8" CL 8'-8" 161 SQ FT 255 SQ FT 124 SQ FT 64 SQ FT 31 SQ FT 570 SQ FT 232 SQ FT 3-PT 2X10 Beam bolted into PT 6X6 Posts MASTER BDRM BATH KITCHEN DINING/FAMILY PORCH ENTRY (2) 2x12 Header STAIRS 3 A-6 3 A-6 1 A-6 1 A-6 1 A-7 1 A-7 3 A-7 3 A-7 2 A-7 2 A-7 Existing Light Vent & Egress to Remain the Same Install Furring Strips to Match Width of Second Floor Framing Stairs 16R @ 7 7/16"" 14T @ 9" + 1 1/8" Nosing Handrails - 34"-38" Above Tread Addition - New LVE to Apply (2 ) 1 3 / 4 " x 9 ½ " M i c r o l l a m H d r . (2 ) 1 3 / 4 " x 9 ½ " M i c r o l l a m H d r . 2X 1 0 J o i s t s @ 1 6 " o . c . Flush W16x40 Steel I-Beam 3" Steel Column Schedule 40 w/ Welded Cap & Base Plate 9' Ceiling (2 ) 2 X 1 0 J o i s t s @ 1 6 " o . c . (2) 2x12 Header Finish Openings to Match Exist. Interior 1 A-6 1 A-6 3 A-6 3 A-6 New Sliding Door to be Installed in Existing Window Rough Opening. Remove framing under existing window & if present, Relocate existing supply register to floor. (2 ) 1 3 / 4 " x 9 ½ " M i c r o l l a m H d r . 3" Steel Column Schedule 40 w/ Welded Cap & Base Plate (2 ) 1 3 / 4 " x 9 ½ " M i c r o l l a m H d r . 2 A-8 2 A-8 Extent of Floor Above (2) 1 3/4"x11 7/8" Microllam Hdr. Remove Exist. Window Infill Opening SD CO SD Hard Wired / Interconnected Combination Smoke / CO Detector Hard Wired / Interconnected Smoke Detector LEGEND 22"X30" Attic access Bath Fan / Light Combo DN Attic Hatch Detail NTS min. 30" clr2x10 Floor Joist 2-2X10 Attic Hatch Frame Casing 1X2 Stop ½" Plywood Hatch cover Finished one side ½" Gyp. Bd Note: Min 22"X30" Attic Access Hatch to Comply w/ R807 Fl o o r P l a n s Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-5 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE Floor Plan-2nd 3/16"=1'-0" 3 A-5 3 A-5 Floor Plan-1st 3/16"=1'-0" 2 A-5 2 A-5 Add Overbuild for DrainageGENERAL NOTES 1)Exterior Headers = 2-2X10's unless noted otherwise. 2)Window Header Height - 83 3/8" Unless noted otherwise. 3)2X6 walls are shown @ 5½" Thickness Typ Exterior wall construction classified as CS-WSP (Continuously Sheathed Wood structural panel) 4)2X4 walls are shown @ 3½" Thickness 5)2X6 Garage Common walls are shown @ 5½" Thickness 6)Interior Bearing & Braced Walls are shown hatched. Braced walls to conform to R602.10 Braced gypsum faced walls to be fastened @ 7" o.c.(edge & field) per R602.3.1 7)Solid Blocking under bearing points to be continuous to Foundation / Beam, or other support structure. 8)Center doors between adjacent walls unless dimensioned otherwise 9)Whole House Ventilation Provide Exhaust fan on Timer per 403.6 of the IECC 2015 Fan to be Panasonic FV11-15VKL1 150CFM w/Timer, 6"Rigid Duct size (Or Equal) WINDOW FALL PROTECTION Where top of the sill of an operable window opening is located less than 24 inches above finished floor and greater than 72 inches above the finished grade or other surface below on the exterior of the building, window shall be provided with a window opening control device that after operation to release, the device shall allow the window to fully open, shall not reduce the net clear opening area of the window unit to less than the area required by Section R310.2.1. Attic Hatch Detail N.T.S. 1 A/5 1 A/5 Roof Trusses to be approved by NYS Design Professional "Hurricane" Clip Truss Detail Horizontal L-Reinforcement Note: Install Continuous Lateral Bracing Perpendicular to Bottom Chords @ 10' O.C. Maximum. All Truss Work to Comply with the "Design Specification for Metal Plate Connected Wood Trusses and Quality Control Manual" of the Truss Plate Institute. NOTE: Roof Trusses to be Certified by Truss Manufacturer. Architect to be Notified of Any and All Truss Bearing. Solid Truss Support to be Provided to Foundation. All Roof Trusses to be fastened to Double Top Plate w/ Simpson H5 Clips or Equal 4-8d 4-8d N.T.S . Simpson Strong-Tie H5 or Equal Gable End Truss Lateral Brace Diagonal Wind Brace 2X6 Blocking (Typ) Rigid Ceiling Material. (Gyp. Bd) Directly appliedEnd Wall Trusses @ 24" o.c.(Typ) GABLE END WIND BRACING DETAIL N.T.S . 4 : 12 4 : 12 5 : 12 5 : 12 5 : 12 NYS Approved Trusses @ 24"O.C. NYS Approved Trusses @ 24"O.C. Shed Roof over Porch Overbuild (Hatched) 2X8 Rafters @ 16" o.c on 2X10 wood plate laid on flat over existing Roof Structure W01W01 26682668 Exist.W01 W01 5068 Exist. Flash as Needed Install Ice & Water Shield 18"min. Vertically Up Wall & At Valley 12 5 24" Bigfoot Footings to 48" Below Grade, min. Undisturbed Soil Overbuild on Existing Roof - See Roof Plan for Construction Notes AdditionExisting Addition Grade 6" Step Down Thermal Envelope in Shaded Area Extend Sheathing Up Face of Raised Heel Truss PT 2X10 LEDGER Fasten Ledger to existing structure Attach to exist. wood rim joist w/ 3 5/8" Fastenmaster® Hvy duty screws @ 8" o.c. Staggered Flash to provide watertight connection Porch Ceiling to Align with House Ceiling PT 2X10 Joists in Galv. Hangers 16"o.c. 3-PT 2X10 Beam 2-PT 2X12 Rim Beam PORCH ROOF Apshalt shingles to match 15# Felt 1/2" OSB sheathing w/ h-Clips Mono Trusses @ 24" o.c. OR 2X6 Rafters @ 16" o.c. 2X4 Ceil. Joists @ 16" o.c. then Finished ceiling material PT 6x6 Post from Roof Structure to Top of Ftg. Flash @ Wall/Roof Intersection Galv. ABA66 Post base by Simpson Strong Tie or Eq. Attach trusses / Rafters to beam w/ Hurricane clips Bottom of Footing to be Min. 48" Below Grade 2X6 truss Ledger continuous securely nailed to solid framing W16x40 w/Blocking For Decorative Wrap (4) 2x12 Carrier Beam 2x10 Joists 16"o.c. Existing CMU Fndn. to Remain 2x10 Joists 16"o.c. 4" Concrete Slab R-15 Rigid Insulation Addition Floor Height to Align w/Existing Floor (2) 2x10 Joists 16"o.c.2x10 Joists 16"o.c. R-30 Insulation at Overhang Existing Notched Post detail NTS Existing Fndn. to Remain 4" Concrete Slab Bottom of Ftg. 48"min. Below Grade 2x10 Joists 16"o.c. (Bridging @ mid-span typ.) 14" Heel 12" R-38 F.G. Batt Insulation 2x10 Joists 16"o.c. (Bridging @ mid-span typ.) 12 5 12 5 Cont. Ridge Vent R-15 Rigid Insulation, typ. 14" Insul vent Baffle Extend Sheathing up over face of raised heel truss Fasten to ea truss w/ min of 3-8d nails. Overlap Wall Plates 6" min. 12" R-38 F.G. Insul. 14" Truss heel. Ext. Wall Building Section 3/16"=1'-0" 1 A/6 1 A/6 Ro o f P l a n a n d Bu i l d i n g S e c t i o n s For full Material Call-Outs & specs Refer to Typ. wall Section on Sheet A-8 TRUSS NOTE Truss design drawings & Layouts, prepared in conformance to Section R802.10.1, shall be provided to the building official and approved prior to installation or at time of framing inspection. Roof Plan 3/16"=1'-0" 2 A/6 2 A/6 Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-6 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE Building Section 3/16"=1'-0" 3 A-6 3 A-6 5 A-4 5 A-4 1a A-6 1a A-6 Notched Post Detail N.T.S. 1a A/6 1a A/6 2-1/2" dia Through bolts may be substituted with 3-5" FlatLok Structural screws by Fastenmaster or Eq. Typ. Truss Heel Dtl. N.T.S. 3a A-6 3a A-6 3a A-6 3a A-6 Exist.W01W01 W01W01W01W01W01W01 W03W03W03W03 12 5 PT 2x12 Rim Board PT 6x6 Posts, typ. 24" Bigfoot Footings to 48" Below Grade, min. Undisturbed SoilBottom of Footing to be Min. 48" Below Grade PT 6x6 Posts, typ. Vinyl Siding to Match Existing Asphalt Shingles to Match Existing Overbuild on Existing Roof - See Roof Plan for Construction Notes AdditionExisting AdditionExisting Grade Flash as Needed Install Ice & Water Shield 18"min. Vertically Up Wall & At Valley 6" Step Down 12 5 PT 2x12 Rim Board PT 6x6 Posts, typ. 24" Bigfoot Footings to 48" Below Grade, min. Undisturbed SoilBottom of Footing to be Min. 48" Below Grade PT 6x6 Posts, typ. Vinyl Siding to Match Existing Asphalt Shingles to Match Existing Overbuild on Existing Roof - See Roof Plan for Construction Notes AdditionExisting AdditionExisting Grade Flash as Needed Install Ice & Water Shield 18"min. Vertically Up Wall & At Valley 6" Step Down Exist.W01W01 W01W01W01W01W01W01 W03W03W03W03 W01W01 W01W01 W01W01 Exist.Exist. W01W01 W02W02 W03W03 12 5 PT 6x6 Posts 24" Bigfoot Footings to 48" Below Grade, min. Grade Undisturbed Soil Bottom of Footing to be Min. 48" Below Grade PT 6x6 Posts Vinyl Siding to Match Existing Asphalt Shingles to Match Existing Overbuild on Existing Roof - See Roof Plan for Construction Notes Addition Existing Addition Existing PT 2x12 Rim Board Flash as Needed Install Ice & Water Shield 18"min. Vertically Up Wall & At Valley 12 5 PT 6x6 Posts 24" Bigfoot Footings to 48" Below Grade, min. Grade Undisturbed Soil Bottom of Footing to be Min. 48" Below Grade PT 6x6 Posts Vinyl Siding to Match Existing Asphalt Shingles to Match Existing Overbuild on Existing Roof - See Roof Plan for Construction Notes Addition Existing Addition Existing PT 2x12 Rim Board Flash as Needed Install Ice & Water Shield 18"min. Vertically Up Wall & At Valley W01W01 W01W01 W01W01 Exist.Exist. W01W01 W02W02 W03W03 6068 6068 Exist. Exist. 6068 W05W05W05W05 6" 12 5 PT 2x12 Rim Board PT 6x6 Posts, typ. 24" Bigfoot Footings, typ. Undisturbed SoilBottom of Footings to be Min. 48" Below Grade PT 6x6 Posts, typ. Vinyl Siding to Match Existing Asphalt Shingles to Match Existing 12 5 Chimney Surround Siding TBD by Owner Existing Shingles and Siding New Sliding Door to Replace Existing Window 6" Step Down Flash as Needed @ Porch Roof/Wall Intersection 6" 12 5 PT 2x12 Rim Board PT 6x6 Posts, typ. 24" Bigfoot Footings, typ. Undisturbed SoilBottom of Footings to be Min. 48" Below Grade PT 6x6 Posts, typ. Vinyl Siding to Match Existing Asphalt Shingles to Match Existing 12 5 Chimney Surround Siding TBD by Owner Existing Shingles and Siding New Sliding Door to Replace Existing Window 6" Step Down Flash as Needed @ Porch Roof/Wall Intersection 6068 6068 Exist. Exist. 6068 W05W05W05W05 West Elevation 3/16"=1'-0"El e v a t i o n s 2 A-7 2 A-7 East Elevation 3/16"=1'-0" 3 A-7 3 A-7 South Elevation 3/16"=1'-0" 1 A-7 1 A-7 Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-7 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE 5 12 4'-0" 9'-1 1/8" 8'-1 1/8" 1/2" OSB SHEATHING w/ H-Clips NYS Apprvd. TRUSSES 24" 0.C. Hurricane Tie-down Clips @ Ea. Truss 1" CONT. AIR SPACE ASPHALT SHINGLES FELT PAPER Ice and Water Shield up 24" min from inside of Exterior Wall Line R-49 (Min) F.G. CEILING INSULATION w/ Vapor Barrier ½" DRYWALL CEILING. R-38 Acceptable if Top Plate is Not Compressed DOUBLE 2" X 6" TOP PLATE ¾" T & G OSB SUB-FLOOR (Glued & Screwed) DBL. 4" Lap Siding House Wrap 7/16" OSB Exterior Sheathing 4" CONCRETE SLAB BACKFILL WITH GRANULAR MATERIAL 2" X 6" Treated Sill Plate Foam Sill Seal 1/2" Anchor Bolts @ 6'-0" O.C. Minimum 12" From End of Run PT 2X4 TOP & BOTTOM PLATE 2X4 STUD FRAMING @ 24"O.C. R-15 RIGID INSULATION COVER COMPLETELY W/ FSK PAPER #4 DOWELS @ 2'-0" O.C. TO TIE TO ADJACENT STEEL 8" X 16" CONT. CONCRETE FOOTING (2) #4 BARS CONT. 20" MINIMUM LAP SPLICE UNDISTURBED SOIL EXPANSION JOINT FILTER FABRIC 4" DRAIN TILE 8" GRAVEL FILL 6 MIL. VAPOR BARRIER 4" GRAVEL BASE RIM JOIST INSULATION GRADE RIM JOIST INSULATION 1/2" DRYWALL CEILING 2" X 10" RIM JOIST 7/16" OSB SHEATHING 2x10 FLOOR JOISTS @16" o.c. 2" X 6" BOTTOM PLATE 5 1/2" Wall Studs 16" O.C. 5 1/2" Wall Insulation Poly Vapor Barrier 1/2" Drywall GALV. DRIP EDGE ALUM. FASCIA 2" X 6" SUB FASCIA #4 REBAR (2 TYPICAL) HORIZ. DOUBLE 2" X 6" TOP PLATE 2" X 10" RIM JOIST 7/16" OSB SHEATHING 8" POURED CONCRETE WALL #5 BAR VERT. @ 48" o.c. (Tie #5 Bar to Footing dowels) DAMP PROOFING (TO GRADE) Frost Wall to Extend a min of 48" Below Grade. Final Depth to be determined in Field in order to provide Bearing on Undisturbed soil below Frostline. (min) VENTED VINYL SOFFIT @ Eaves SOLID VINYL SOFFIT@ Gables DBL. 4" Lap Siding House Wrap 7/16" OSB Exterior Sheathing ¾" T & G OSB SUB-FLOOR (Glued & Screwed) 2" X 6" BOTTOM PLATE 5 1/2" Wall Studs 16" O.C. 5 1/2" Wall Insulation Poly Vapor Barrier 1/2" Drywall 2x10 FLOOR JOISTS @16" o.c. 5 12 4'-0" 9'-1 1/8" 8'-1 1/8" 1/2" OSB SHEATHING w/ H-Clips NYS Apprvd. TRUSSES 24" 0.C. Hurricane Tie-down Clips @ Ea. Truss 1" CONT. AIR SPACE ASPHALT SHINGLES FELT PAPER Ice and Water Shield up 24" min from inside of Exterior Wall Line R-49 (Min) F.G. CEILING INSULATION w/ Vapor Barrier ½" DRYWALL CEILING. R-38 Acceptable if Top Plate is Not Compressed DOUBLE 2" X 6" TOP PLATE ¾" T & G OSB SUB-FLOOR (Glued & Screwed) DBL. 4" Lap Siding House Wrap 7/16" OSB Exterior Sheathing 4" CONCRETE SLAB BACKFILL WITH GRANULAR MATERIAL 2" X 6" Treated Sill Plate Foam Sill Seal 1/2" Anchor Bolts @ 6'-0" O.C. Minimum 12" From End of Run PT 2X4 TOP & BOTTOM PLATE 2X4 STUD FRAMING @ 24"O.C. R-15 RIGID INSULATION COVER COMPLETELY W/ FSK PAPER #4 DOWELS @ 2'-0" O.C. TO TIE TO ADJACENT STEEL 8" X 16" CONT. CONCRETE FOOTING (2) #4 BARS CONT. 20" MINIMUM LAP SPLICE UNDISTURBED SOIL EXPANSION JOINT FILTER FABRIC 4" DRAIN TILE 8" GRAVEL FILL 6 MIL. VAPOR BARRIER 4" GRAVEL BASE RIM JOIST INSULATION GRADE RIM JOIST INSULATION 1/2" DRYWALL CEILING 2" X 10" RIM JOIST 7/16" OSB SHEATHING 2x10 FLOOR JOISTS @16" o.c. 2" X 6" BOTTOM PLATE 5 1/2" Wall Studs 16" O.C. 5 1/2" Wall Insulation Poly Vapor Barrier 1/2" Drywall GALV. DRIP EDGE ALUM. FASCIA 2" X 6" SUB FASCIA #4 REBAR (2 TYPICAL) HORIZ. DOUBLE 2" X 6" TOP PLATE 2" X 10" RIM JOIST 7/16" OSB SHEATHING 8" POURED CONCRETE WALL #5 BAR VERT. @ 48" o.c. (Tie #5 Bar to Footing dowels) DAMP PROOFING (TO GRADE) Frost Wall to Extend a min of 48" Below Grade. Final Depth to be determined in Field in order to provide Bearing on Undisturbed soil below Frostline. (min) VENTED VINYL SOFFIT @ Eaves SOLID VINYL SOFFIT@ Gables DBL. 4" Lap Siding House Wrap 7/16" OSB Exterior Sheathing ¾" T & G OSB SUB-FLOOR (Glued & Screwed) 2" X 6" BOTTOM PLATE 5 1/2" Wall Studs 16" O.C. 5 1/2" Wall Insulation Poly Vapor Barrier 1/2" Drywall 2x10 FLOOR JOISTS @16" o.c. DN CL CL 3/4" GROUT 1 1/2" 7" SQUARE FOUNDATION TOP OF CONCRETE 4 - 3/4" DIA. ANCHOR BOLTS 5" EMBEDMENT 3/4" THICK PLATE 3" STANDARD PIPE COLUMN TYP. 5/16" DN DOOR SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTION D01 2 1 6068 72"80"EXT. DOUBLE HINGED-DOOR F01 D02 1 1 6068 72"80"EXT. SLIDER-GLASS PANEL D03 4 2 2668 30"80"HINGED-DOOR PS01 D04 3 2 5068 60"80"SLIDER-SLAB DN WINDOW SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY FLOOR SIZE R/O DESCRIPTION COMMENTS W01 8 1 30410 36"X58"DOUBLE HUNG W02 1 2 30310 36"X46"DOUBLE HUNG TEMPERED W03 3 2 30410 36"X58"DOUBLE HUNG W04 1 2 4020 48"X24"SINGLE AWNING TEMPERED W05 3 2 6020 72"X24"TRIPLE SLIDING Dr a w i n g T i t l e Pr o j e c t Na m e : AD D I T I O N 63 2 L a k e A v e Sa r a t o g a S p r i n g s , N Y 1 2 8 6 6 A-8 12/12/2025 As Noted Seal Drawn By: Engineer: Owner Approval: Scale: Date: Drawing No. No. Record of Work Date K.L.H. Va n G u i l d e r E n g i n e e r i n g 33 3 K i n g s l e y R d B u r n t H i l l s , N Y 12 0 2 7 (5 1 8 ) 4 9 1 - 3 2 8 7 va n g u i l d e r e n g @ g m a i l . c o m WA R N I N G IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D P R O F E S S I O N A L E N G I N E E R , T O A L T E R IN A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R R E P O R T S T O W H I C H T H E S E A L O F PR O F E S S I O N A L E N G I N E E R H A S B E E N A P P L I E D Garry F. Nathan PE Ty p i c a l W a l l S e c t i o n , De t a i l a n d S c h e d u l e s Typical Wall Section 3/8"=1'-0" 2 A-8 2 A-8 Post Conn. Dtl N.T.S. 3 A-8 3 A-8 Door Schedule N.T.S. 5 A-8 5 A-8 Window Schedule N.T.S. 4 A-8 4 A-8 1 A-8 1 A-8 Light Vent and Egress Schedule N.T.S. 2020 Energy Code Requirements - ZONE 5 Climate Zone Fenestration U-Factor Skylight U-Factor Ceiling R-Value Wood Framed Wall R-Value Floor R-Value Crawl Space Wall R-Value Slab R-Value & Depth 5 Code .30 .55 49/38 20 30 15/19 R15 to 48" TABLE N1102.1.2 (402.1.2) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT 5 Supply .30 .55 38 21 30 15/19 N/A S t a f f o r d s B r i d g e R d . ( C o u n t y R t . 6 7 ) NYS Route 29 aka Lake Avenue PROPOSED ADDITION PROPOSED PORCH