Loading...
HomeMy WebLinkAbout20250972 33 Phila St. Herbies Burgers Signage & Exhaust NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Chris Bennett Leslie DiCarlo Jeff Gritsavage Geoff Wood Karen Cavotta Alison Dockum, Alternate Christina Abele, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20250972 33 Phila St. Herbie’s Burgers Signage & Exhaust 33 Phila St. Saratoga Springs, New York 12866 involving Historic review of wall mounted signage within the Urban Core (UC) District, tax parcel # 165.68-1-2, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on November 19, 2025:  Approve the project with the following conditions: Exhaust fan installation is approved; applicant to return for approval on signage Record of vote: motion to approve made by G Wood, seconded by J Gritsavage : passed 6-0 In favor: TEhinger, CBennett, LDiCarlo, JGritsavage, K Cavotta, G Wood As a result of this decision, the applicant:  may proceed with the portions of the proposed project as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent PLENUM FIRE SUPPRESSION SYSTEM NOZZLES & TANK INSTALLER SHALL VERIFY TANKSIZE WITH MANUFACTURER. TANK SIZE PROTEX II OR EQUAL) 1/2 SCH. 40 BLKS STL. ANSUL SYSTEM CONTROL CENTER 3.0 GAL. TANK 1.6 GALLON 3.0 GALLON 4.6 GALLON 4.6 GALLON 6.0 GALLON 6.0 GALLON MAX# FLOW POINTS 5 10 15 15 20 20 CLASS, WET CHEMICAL MA. 30 FT FROM COOKING AREA REMOTE PULL STATION MIL. 12 FT. FROM HOOD AUTOMATIC SHUT-OFF SOLENOID CONTROLS ANSUL SYSTEM & COMPONENTS TO COMPLY WITH NFPA 17A & NFPA 96 AND ALL COMPONENTS U. L. APPROVED. ALL WIRING AND ELECTRICAL EQUIPMENT SHALL COMPLY W/ NPFA 70 AND THE NATIONAL ELECTRIC CODE. PLUMBER TO INSTALL GAS SHUT-OFF Valve w/ TIE TO FIRE SUPPRESSION SYSTEM. SUPPRESSION SYSTEM TIED TO ALARM SYSTEM w/ MICRO-SWITCH BY ALARM CONTRAC-TOR FIRE EXTINGUISHERS CLASS A-B-C EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED & READILY ACCESSIBLE. INSTALLED IN ACCORDANCE w/ NFPA REQUIREMENTS. CLASS K EXTINGUISHERS SHALL BE PROVIDED FOR ALL AREAS WITH COOKING EQUIP-MENT AND COMBUSTIBLE COOKING MEDIA IN ACCORDANCE WITH NFPA REQUIRE-MENTS. CONTRACTOR TO VERIFY ALL PIPING SIZES WITH APPLI-ANCE MANUF. SPECS. ALL APPLIANCES HAVE INDIVIDUAL GAS SHUT-OFF VALVES AT APPLIANCE GAS PIPING NOTES: 1. GAS PIPING SHALL BE BLACK STEEL SHC. 40 OR AS PERMITTED BY CODE 2. PIPING CONNECTIONS SHALL BE THREAD-ED UNLESS OTHERWISE PERMITTED BY CODE. 3. ALL GAS BURNING EQUIPMENT SHALL BE INSTALLED PER NFPA 54, NFPA 58, NFPA 96 4. ALL APPLIANCES HAVE INDIVIDUAL GAS SHUT-OFF VALVES AT THE APPLIANCE. MAX. PIPE VOLUME MILLILITERS) 1500 1910 3400 2600 4215 3465 MAX. VOLUME ALLOWED BETWEEN FIRS & LAST NOZZLE (MILLILITERS) 400 1125 3000 2000 1688/SIDE 1313/ SIDE 4 2 I F O V E R 40 W T 1/2 SCH. 40 BLKS STL. 1/2 SCH. 40 BLKS STL. 42" - 48" ABOVE FIN.FL. PORTABLE EXTINGUISHER "K" NOZZLE HEIGHT SHALL BE MIN. 12" MAX. 50" FROM COOKING EQUIPMENT . MECHANICAL PULL STATION SHALL BE LOCATED 10' - 25' FROM THE RANGE HOOD. TOP OF EXTINGUISHERS MA 60" ABOVE FLOOR BOTTOM MIN 4" ABOVE FLOOR ,& DU C T GRILL 36" HO R I Z O N T A L INSTALLER: PROTECT-IT FIRE NEW YORK OCT - 2025 NEW EXHAUST HOOD 33 & 36 Phila St, Saratoga Springs, NY 12866 PROJECT HERBIE'S BURGES SARATOGA