Loading...
HomeMy WebLinkAbout20250972 33 Phila St. Herbie's Burgers Signage & Exhaust Fan Application- newRevised 01/2021 APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* OWNER(S) (If not applicant)ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DDEESSIIGGNN RREEVVIIEEWW CCOOMMMMIISSSSIIOONN CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ 636 Providence St. Albany, NY 12208 Phil Lambert 180 Riuggles Rd. Sarartoga Springs, NY 12866 Aaron R. Wilson aaronrobertwilson@gmail.com phil@lamberts.com 33 Phila St. Saratoga Springs, NY 165 1 2 UC UC Installation of interior LED illuminated wall sign cabinet that is 2.5’ tall by 6’ wide (15 square feet) above the restaurant’s door. Please see attached spec sheet. PUTNAM ST. STORE FRONTAGE IS 63’-8" In addition to signage, a kitchen exhaust hood will be placed back in the same spot that an exhaust once protruded the building. Please see attached spec sheet. Instead of a rendering, a photo of where the exhaust hood once came out is included to the right of the drawing. 10/27/2025 (518) 917-3367 (201) 264-6570 10/01/25 In addition to signage, an exhaust hood for the kitchen exhaust system will be placed on the roof in an attempt to be less noticeable from street level. A diagram and photo is included at the end of this packet. **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 Request for extension of current approval Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure (4 units +) -Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? No  Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Revised 01/2021 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 6 12 FT HOOD FRONT VIEW SCALE: 1/4"/1'-0" 12 FT HOOD FRONT VIEW SCALE: 1/4"/1'-0" MAKE UP AIR 12' - 1" EXHAUST HOOD SINGLE TANK FRYER GAS SINGLE TANK FRYER GAS SINGLE TANK FRYER GRILL 36' GAS 18" 18"18" KITCHEN HOOD 12 FEET DUCT 12"x12" HOOD 12 FOOT . INSTALLER: PROTECT-IT FIRE NEW YORK OCT - 2025 NEW EXHAUST HOOD 33 & 36 Phila St, Saratoga Springs, NY 12866 PROJECT HERBIE'S BURGES SARATOGA 2' - 0 7' - 0 HOOD SECTION A-A' SCALE:1/4"=1'-0" MI N 9 0 I N 10 ' 14"x14" INSTALLER: PROTECT-IT FIRE NEW YORK OCT - 2025 NEW EXHAUST HOOD 33 & 36 Phila St, Saratoga Springs, NY 12866 PROJECT HERBIE'S BURGES SARATOGA STANDARD DUCT INSULATION ON MAKE-UP AIR DUCTS HORIZONTAL DUCTS SHALL HAVE MIN. 2% SLOPE UP TO 75 FT LONG, 8% IF LONGER. IN HORIZONTAL DUCTS EVERY 20 FEET, AND 10 FEET FROM ALL CHANGES IN DIRECTION GREATER THAN 45 DEGREES. INSTALLATION OF CERAMIC FIBER INSULATION: 3M FIRE BARRIER DUCT WRAP 615 + (OR EQUAL WITH PRE-APPROVAL OF SPECS) INSTALLER SHALL COMPLY WITH MANUFACTURES INSTLLATION GUIDE. INSULATION SHALL BE INSTALED PERMANENTLY WITH MIN. 1/2" STEEL BANDING, RATED TAPE AND PINS OR SPEED CLIPS APPROVED BY THE MANUFACTURER. REFER TO GUIDE FOR PROPER SEAM OVERLAPS. CLEARENCES AND TREATMENT OF ACCESS PANELS AND DUCT SUPPORTS. NOTE: INSTALER TO CONSULT WITH CODE ENFORCEMENT AND/OR FIRE MARSHAL FOR WRAPS THAT REQUIRE A 2 - LAYER INSTALLATION. IF INSTALLATION MUST BE INSPECTED AFTER FIRST LAYER IS APPLIED AND AGAIN AFTER SECOND LAYER IS APPLIED FAN 28" MAKE-UP AIR INTAKE FAN 12 FT HOOD FRONT VIEW SCALE: 1/4"/1'-0" 12 FT. HOOD 12 FT HOOD FRONT VIEW SCALE: 1/4"/1'-0" GRILL 36" 80 " INSTALLER: PROTECT-IT FIRE NEW YORK OCT - 2025 NEW EXHAUST HOOD 33 & 36 Phila St, Saratoga Springs, NY 12866 PROJECT HERBIE'S BURGES SARATOGA 10 FT. MIN. CLEAR. TO ALL EXHAUST FANS OR VENTS STANDARD DUCT INSULATION ON MAKE-UP-AIR DUCTS CLEANOUT PANELS @ ALL TURNS & RISERS NOTE: INSTALER TO CONSULT WITH CODE ENFORCEMENT AND/OR FIRE MARSHAL FOR WRAPS THAT REQUIRE A 2 - LAYER INSTALLATION. IF INSTALLATION MUST BE INSPECTED AFTER FIRST LAYER IS APPLIED AND AGAIN AFTER SECOND LAYER IS APPLIED INSTALLERS SHALL ADJUST FAN DRIVES OR BELTS & PULLEYS TO BALANCE AIR FLOW INSTALLER & OWNER TO VERIFY SIZE OF COOKING EQUIPMENT TO VERIFY THAT ALL EQUIPMENT FITS UNDER HOOD WITH REQUIRED DISTANCES FROM HOOD EDGES. VENTILATION SYSTEMS NOTES: HOOD SHALL BE MADE OF 18 GA. STAINLESS STEEL AND CONSTRUCTED ACCORDING TO NFPA 96, ETL -LISTED. ALL SEAMS, JOINTS, & PENETRATIONS SHALL BE FULLY WELDED. CANOPY LIGHTS: 100 WATT, VAPOR-PROF, HIGH TEMPERATURE ASSEMBLY, WIRE-GUARD, SHOCK-PROF GLOVE, MIN. 48” O.C. DUCTS SHALL BE 18 GA. STAINLESS STEEL OR 16 GA. CARBON STEEL. ALL JOINTS, SEAMS, & PENETRATIONS SHALL BE FULLY WELDED. HOOD & DUCTS SHALL BE A MI 18 INCHES FROM ANY COMBUSTIBLE MATERIAL AIR VELOCITY THROUGH ANY DUCT SHALL NO BE LESS THAN 500 FT. /MIN HORIZONTAL DUCTS SHALL HAVE MIN. 2% SLOPE UP TO 75 FT LONG, 8% IF LONGER. PROVIDE REMOVABLE CLEAN OUTS AT THE BASE OF ALL VERTICAL RISERS OVER 20 INCHES, AND IN HORIZONTAL DUCTS EVERY 20 FEET, AND 10 FEET FROM ALL CHANGES OF DIRECTION GREATER THAN 45 DEGREES. CLEAN OUTS-ACCESS PANELS HAVE GASKET OF SEALANT RATED 1500 DEG. F. WITH A SIGN STATING “ACCESS PANEL - DO NOT OBSTRUCT” INSTALLATION OF CERAMIC FIBER INSULATION: INSTALLER SHALL COMPLY WITH MANUFACTURERS INSTALLATION GUIDE. INSULATION SHALL BE INSTALLED PERMANENTLY WITH MIN. 1/2 STEEL BANDING, RATED TAPE AND PINS OR SPEED CLIPS APPROVED BY THE MANUFACTURER. REFER TO GUIDE FOR PROPER SEAM OVERLAPS, CLEARANCES, AND TREATMENT OF ACCESS PANELS AND DUCT SUPPORTS. 506.3.2.2, 2020 NYS MECH. CODE: DUCT-TO-HOOD JOINTS: DUCT-TO-HOOD JOINTS SHALL BE MADE WITH CONTINUOUS INTERNAL OR EXTERNAL LIQUID-TIGHT WELDED OF BRAZED JOINTS. SUCH JOINTS SHALL BE SMOOTH, ACCESSIBLE FOR INSPECTION, AND WITHOUT GREASE TRAPS. ALLOWABLE EXCEPTIONS TO THIS SECTION ARE NOT PROPOSED IN THIS DESIGN. IF HOOD INSTALLER OR MANU- FACTURER PROPOSES ANY OF THESE EXCEPTIONS, THEY MUS BE SHOWN IN SHOP DRAWINGS AND PROVIDED TO THE ARCHITECT/DESIGNER AND BUILDING INSPECTOR FOR APPROVAL PRIOR TO INSTALLATION. 506.3.2.5, 2020 NYS MECH. CODE: GREASE DUCT TEST PRIOR TO THE USE OR CONCEALMENT OF ANY PORTION OF A GREASE DUCT SYSTEM, A LEAKAGE TEST SHALL BE PERFORMED. DUCTS SHALL BE CONSIDERED TO BE CONCEALED WHERE INSTALLED IN SHAFTS OR COVERED BY COATINGS OF WRAPS THAT PREVENT THE DUCTWORK FROM BEING VISUALLY INSPECTED ON ALL SIDES. THE PERMIT HOLDER SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY EQUIPMENT AND PERFORM THE GREASE DUCT LEAKAGE TEST. A LIGHT TEST SHALL ME PERFORMED TO DETERMINE THAT ALL WELDED AND BRAZED JOINTS ARE LIQUID-TIGHT A LIGHT TEST SHALL BE PERFORMED BY PASSING A LAMP HAVING A POWER RATING O NO LESS THAN 100 WATTS THROUGH THE ENTIRE SECTION OF DUCTWORK TO BE TESTED. THE LAMP SHALL BE OPEN SO AS TO EMIT LIGHT EQUALLY IN ALL DIRECTIONS PERPENDICULAR TO THE DUCT WALLS. A TEST SHALL BE PERFORMED FOR THE ENTIRE DUCT SYSTEM, INCLUDING THE HOOD-TO-DUCT CONNECTION, THE DUCT WORK SHALL BE PERMITTED TO BE TESTED IN SECTIONS, PROVIDED THAT EVERY JOINT IS TESTED. FOR LISTED FACTORY-BUILT GREASE DUCTS, THIS TEST SHALL BE LIMITED TO DUCT JOINTS ASSEMBLED IN THE FIELD AND SHALL EXCLUDE FACTORY WELDS. PENETRATION THROUGH NON-RAT- ED ROOF OR WALLS PROVIDE MIN. CLEARANCES: 0” TO NON-COMBUSTIBLES 3” TO LIMITED-COMBUSTIBLES 18” TO COMBUSTIBLES 506.3.13.2 TERMINATION THROUGH AN EXTERIOR WALL. EXHAUST OUTLETS SHALL BE PERMITTED TO TERMINATE THROUGH EXTERIOR WALLS WHERE THE SMOKE, GREASE, GASES, VAPORS AND ODORS IN THE DISCHARGE FROM SUCH TERMINATIONS DO NOT CREATE A PUBLIC NUISANCE OR A FIRE HAZARD. SUCH TERMINATIONS SHALL NOT BE LOCATED WHERE PROTECTED OPENINGS ARE REQUIRED BY THE NEW YORK CITY BUILDING CODE. OTHER EXTERIOR OPENINGS SHALL NOT BE LOCATED WITHIN 3 FEET (914.4 MM) OF SUCH TERMINATIONS. 507.1.1 OPERATION. COMMERCIAL KITCHEN EXHAUST HOOD SYSTEMS SHALL OPERATE WHILE COOKING EQUIPMENT IS IN OPERATION. THE HOOD EXHAUST RATE SHALL COMPLY WITH THE LISTING OF THE HOOD OR SHALL COMPLY WITH SECTION 507.5. THE EXHAUST FAN SERVING A TYPE I HOOD SHALL HAVE AUTOMATIC CONTROLS THAT WILL ACTIVATE THE FAN WHEN ANY APPLIANCE THAT REQUIRES SUCH TYPE I HOOD IS TURNED ON, OR A MEANS OF INTERLOCK SHALL BE PROVIDED THAT WILL PREVENT OPERA- TION OF SUCH APPLIANCES WHEN THE EXHAUST FAN IS NOT TURNED ON. WHERE ONE OR MORE TEMPERATURE OR RADIANT ENERGY SENSORS ARE USED TO ACTIVATE A TYPE I HOOD EXHAUST FAN, THE FAN SHALL ACTIVATE NOT MORE THAN 15 MINUTES AFTER THE FIRST APPLIANCE SERVED BY THAT HOOD HAS BEEN TURNED ON. A METHOD OF INTERLOCK BETWEEN AN EXHAUST HOOD SYSTEM AND APPLIANCES EQUIPPED WITH STANDING PILOT BURNERS SHALL NOT CAUSE THE PILOT BURNERS TO BE EXTINGUISHED. A METHOD OF INTERLOCK BETWEEN AN EXHAUST HOOD SYSTEM AND COOKING APPLIANCES SHALL NOT INVOLVE OR DEPEND UPON ANY COMPONENT OF A FIRE-EXTINGUISHING SYSTEM. HOOD EXHAUST VOLUMES MAY BE REDUCED DURING PART-LOAD COOKING CONDITIONS ONLY FOR LISTED HOODS THAT ARE PROVIDED WITH VARIABLE SPEED OR MULTI SPEED CONTROLS FROM OR AS APPROVED BY THE HOOD MANUFACTURER. SUCH CONTROLS SHALL AUTOMATICALLY OPERATE THE EXHAUST SYSTEM TO MAINTAIN CAPTURE AND REMOVAL OF COOKING EFFLUENTS AS REQUIRED BY THIS SECTION. REDUCED VOLUMES SHALL MAINTAIN CAPTURE AND REMOVAL OF EFFLUENTS FROM THE IDLE COOKING APPLIANCES THAT ARE OPERATING IN A STANDBY MODE. MINIMUM DUCT VELOCITIES SHALL BE MAINTAINED DURING PART LOAD OPERATION. THE REPLACEMENT AIR SYSTEM SHALL BE OPERATED IN COORDINATION WITH THE VARIABLE FLOW OPERATION OF THE EXHAUSTS. 507.3.2.5 2020 NYS MECH. CODE: PERFORMANCE TEST A PERFORMANCE TEST SHALL BE CONDUCTED UPON COMPLETION AND BEFORE FINAL APPROVAL OF THE INSTALLATION OF A VENTILATION SYSTEM SERVING COMMERCIAL COOKING APPLIANCES. THE TEST SHALL VERIFY THE RATE OF EXHAUST AIR- FLOW REQUIRED BY SECTION 507.5, MAKEUP AIRFLOW REQUIRED BY SECTION 508 AND PROPER OPERATION AS SPECIFIED IN THIS CHAPTER. THE PERMIT HOLDER SHALL FURNISH THE NECESSARY TEST EQUIPMENT AND DEVICES REQUIRED TO PERFORM THE TESTS. 507.6 202 NYS MECH. CODE PERFORMANCE TEST CAPTURE AND CONTAINMENT TEST. THE PERMIT HOLDER SHALL VERIFY CAPTURE AND CONTAINMENT PERFORMANCE OF THE EXHAUST SYSTEM. THIS FIELD TEST SHALL BE CONDUCTED WITH ALL APPLIANCES UNDER THE HOOD AT OPERATING TEMPERA- TURES, WITH ALL SOURCES OF OUTDOOR AIR PROVIDING MAKEUP AIR FOR THE HOOD OPERATING AND WITH ALL SOURCES OF RECIRCULATED AIR PROVIDING CONDITIONING FOR THE SPACE IN WHICH THE HOOD IS LOCATED OPERATING. CAPTURE AND CONTAINMENT SHALL BE REV-IVIED VISUALLY BY OBSERVING SMOKE OR STEAM PRODUCED BY ACTUAL OR SIMULATED COOKING, SUCH AS THAT PROVIDED BY SMOKE CANDLES AND SMOKE PUFFERS. SMOKE BOMBS SHALL NOT BE USED 508.1 MAKEUP AIR. MAKEUP AIR SHALL BE SUPPLIED DURING THE OPERATION OF COMMERCIAL KITCHEN EXHAUST SYSTEMS THAT ARE PROVIDED FOR COMMERCIAL COOKING APPLIANCES. THE AMOUNT OF MAKEUP AIR SUPPLIED TO THE BUILDING FROM ALL SOURCES SHALL BE APPROXIMATELY EQUAL TO THE AMOUNT OF EXHAUST AIR FOR ALL EXHAUST SYSTEMS FOR THE BUILDING. THE MAKEUP AIR SHALL NOT REDUCE THE EFFECTIVENESS OF THE EXHAUST SYSTEM. MAKEUP AIR SHALL BE PROVIDED BY GRAVITY OR MECHANICAL MEANS OR BOTH. MECHANICAL MAKEUP AIR SYSTEMS SHALL BE AUTOMATICALLY CON- TROLLED TO START AND OPERATE SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. MAKEUP AIR INTAKE OPENING LOCATIONS SHALL COMPLY WITH SECTION 401.4. 508.1.1 MAKEUP AIR TEMPERATURE. THE TEMPERATURE DIFFERENTIAL BETWEEN MAKEUP AIR AND THE AIR IN THE CONDITIONED SPACE SHALL NOT EXCEED 10ºF (6ºC) EXCEPT WHERE THE ADDED HEATING AND COOLING LOADS OF THE MAKEUP AIR DO NOT EXCEED THE CAPACITY OF THE HVAC SYSTEM INSTALLER: PROTECT-IT FIRE NEW YORK OCT - 2025 NEW EXHAUST HOOD 33 & 36 Phila St, Saratoga Springs, NY 12866 PROJECT HERBIE'S BURGES SARATOGA PLENUM FIRE SUPPRESSION SYSTEM NOZZLES & TANK INSTALLER SHALL VERIFY TANKSIZE WITH MANUFACTURER. TANK SIZE (PROTEX II OR EQUAL) 1/2 SCH. 40 BLKS STL. ANSUL SYSTEM CONTROL CENTER 3.0 GAL. TANK 1.6 GALLON 3.0 GALLON 4.6 GALLON 4.6 GALLON 6.0 GALLON 6.0 GALLON MAX# FLOW POINTS 5 10 15 15 20 20 CLASS, WET CHEMICAL MA. 30 FT FROM COOKING AREA REMOTE PULL STATION MIL. 12 FT. FROM HOOD AUTOMATIC SHUT-OFF SOLENOID CONTROLS ANSUL SYSTEM & COMPONENTS TO COMPLY WITH NFPA 17A & NFPA 96 AND ALL COMPONENTS U. L. APPROVED. ALL WIRING AND ELECTRICAL EQUIPMENT SHALL COMPLY W/ NPFA 70 AND THE NATIONAL ELECTRIC CODE. PLUMBER TO INSTALL GAS SHUT-OFF Valve w/ TIE TO FIRE SUPPRESSION SYSTEM. SUPPRESSION SYSTEM TIED TO ALARM SYSTEM w/ MICRO-SWITCH BY ALARM CONTRAC-TOR FIRE EXTINGUISHERS CLASS A-B-C EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED & READILY ACCESSIBLE. INSTALLED IN ACCORDANCE w/ NFPA REQUIREMENTS. CLASS K EXTINGUISHERS SHALL BE PROVIDED FOR ALL AREAS WITH COOKING EQUIP-MENT AND COMBUSTIBLE COOKING MEDIA IN ACCORDANCE WITH NFPA REQUIRE-MENTS. CONTRACTOR TO VERIFY ALL PIPING SIZES WITH APPLI-ANCE MANUF. SPECS. ALL APPLIANCES HAVE INDIVIDUAL GAS SHUT-OFF VALVES AT APPLIANCE GAS PIPING NOTES: 1. GAS PIPING SHALL BE BLACK STEEL SHC. 40 OR AS PERMITTED BY CODE 2. PIPING CONNECTIONS SHALL BE THREAD-ED UNLESS OTHERWISE PERMITTED BY CODE. 3. ALL GAS BURNING EQUIPMENT SHALL BE INSTALLED PER NFPA 54, NFPA 58, NFPA 96 4. ALL APPLIANCES HAVE INDIVIDUAL GAS SHUT-OFF VALVES AT THE APPLIANCE. MAX. PIPE VOLUME (MILLILITERS) 1500 1910 3400 2600 4215 3465 MAX. VOLUME ALLOWED BETWEEN FIRS & LAST NOZZLE (MILLILITERS) 400 1125 3000 2000 1688/SIDE 1313/ SIDE (4 2 I F O V E R 40 # W T . ) 1/2 SCH. 40 BLKS STL. 1/2 SCH. 40 BLKS STL. 42" - 48" ABOVE FIN.FL. PORTABLE EXTINGUISHER "K" NOZZLE HEIGHT SHALL BE MIN. 12" MAX. 50" FROM COOKING EQUIPMENT . MECHANICAL PULL STATION SHALL BE LOCATED 10' - 25' FROM THE RANGE HOOD. TOP OF EXTINGUISHERS MA 60" ABOVE FLOOR BOTTOM MIN 4" ABOVE FLOOR ,& DU C T GRILL 36" HO R I Z O N T A L INSTALLER: PROTECT-IT FIRE NEW YORK OCT - 2025 NEW EXHAUST HOOD 33 & 36 Phila St, Saratoga Springs, NY 12866 PROJECT HERBIE'S BURGES SARATOGA