Loading...
HomeMy WebLinkAbout20250872 127 George St Addition ApplicationRevised 01/2021 APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 6 E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 3 9 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Title Page & Notes 25-03-017 06-16-25 SK RN ADDITION / RENOVATION -G1 FRAMING NOTES: 1. STRUCTURAL FRAMING MEMBERS SHALL BE SPF #2 OR BETTER UNLESS OTHERWISE STATED. 2. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO FLOOR JOISTS ACCORDING TO NAILING SCHEDULE. ROOF AND WALL SHEATHING SHALL BE NAILED ACCORDING TO NAILING SCHEDULE. 3. SILL PLATES SHALL BE PRESSURE TREATED WOOD OR WOOD OF NATURAL RESISTANCE TO DECAY. 4. FRAMING MEMBERS SHALL NOT BE CUT OR NOTCHED IN EXCESS TO: BEARING WALL OR NON BEARING WALL MEMBERS: IRC R602.6. FLOOR MEMBERS: 2020 RESIDENTIAL CODE OF NYS 5. PROVIDE SOLID BLOCKING FOR FLOOR JOISTS UNDER ALL INTERMEDIATE BEARING WALLS AND AT ENDS BY FULL DEPTH BLOCKING, PROVIDE BLOCKING EVERY 8' MAX. OF FLOOR JOIST SPAN. 6. PROVIDE WOOD TRUSSES ABLE TO SUSTAIN THE STATED DESIGN LOADS. TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR TRUSS DESIGN. 7. ENGINEERED WOOD PRODUCTS TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 8. ALL WOOD INCLUDING POSTS LOCATED NEARER THAN 18" (12" FOR GIRDERS) TO EARTH OR LOCATED ON CONCRETE PLACED ON EARTH SHALL BE PRESSURE TREATED OR WOOD OF NATURAL RESISTANCE TO DECAY. 9. HEADERS ARE TO BE BUILT UP (PER CODE) IN FRAMED WALLS U.N.O.-SUPPORT EACH HEADER W/ DOUBLE TRIMMER STUDS WHERE OPENINGS ARE 48" WIDE OR GREATER. 10. FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL). FIRE BLOCKING SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: A) IN CONCEALED SPACES OF STUD WALLS, INCLUDING FURRED SPACES, AT CEILING AND FLOOR LEVELS. CONCEALED HORIZONTAL FURRED SPACES SHALL ALSO BE FIRE BLOCKED AT INTERVALS NOT TO EXCEED 10 FT. BATTS OR BLANKETS OF MINERAL OR GLASS FIBER SHALL BE ALLOWED AS FIRE BLOCKING. B) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS. C) IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. D) AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND FLOOR LEVEL, TO RESIST FIRE PASSAGE OF FLAME AND PRODUCTS OR COMBUSTION. E) FIRE BLOCKING OF CORNICES OR A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION. 11. JOISTS EXCEEDING A NOMINAL 2 X 12 SHALL BE SUPPORTED LATERALLY BY SOLID BLOCKING, DIAGONAL BRIDGING, OR A CONTINUOUS 1 X 3 STRIP NAILED ACROSS THE BOTTOM OF JOISTS PERPENDICULAR TO JOISTS AT INTERVALS NOT EXCEEDING 8 FT. 12. PROVIDE FULL BEARING SUPPORT FOR ALL BEAMS (EX. 4X BEAMS SUPPORTED BY (2) 2X OR 4X POSTS, 6X/8X BEAMS SUPPORTED BY 6X/8X POST, ETC). 13. HARDWARE IS TO BE "SIMPSON STRONG-TIE" OR EQUAL. CONSTRUCTION TYPE: V DESIGN PROVISIONS. 2020 RESIDENTIAL CODE OF NYS APPENDIX J EXISTING BUILDINGS AND STRUCTURES DESIGN LOADS: ROOF...............................................50 PSF (SNOW) 15 PSF (DEAD) APPLIED SNOW LOAD...................38.5 PSF ATTIC (W / STORAGE)....................20 PSF ATTIC (W/O STORAGE)..................10 PSF CEILING............................................10 PSF (DEAD) FLOOR (SLEEPING).........................30 PSF (LIVE) 12 PSF (DEAD) FLOOR (NON-SLEEPING)................40 PSF (LIVE) 12 PSF (DEAD) STAIRS..............................................40 PSF HANDRAILS......................................200 LBS (ANY POINT/DIRECTION) DECKS..............................................40 PSF (LIVE) EXTERIOR BALCONY......................60 PSF (LIVE) WIND LOADS: BASIC WIND SPEED (3 SECOND) GUST...........................................................115MPH IMPORTANCE FACTOR (Iw)...............................................................1.0 HIGHEST POINT OF ROOF (FT)...............................................................N/A' TOPOGRAPHIC FACTOR (Kzt)..............................................................1.0 EGRESS REQUIREMENTS 1. THE SILL HEIGHT SHALL NOT BE MORE THAN 44 INCHES ABOVE THE FLOOR. 2. ALL GRADE FLOOR EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.0 SQ/FT. 3. THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES. 4. THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES. THE MINIMUM HORIZONTAL AREA OF THE WINDOW WELL SHALL BE 9.0 SQ/FT WITH A MINIMUM HORIZONTAL PROJECTION AND WIDTH OF 36 INCHES. 5. NET CLEAR OPENING MUST BE 24 INCH MINIMUM HEIGHT & 20 INCH MINIMUM WIDTH. BASEMENT & FIRST FLOOR WINDOWS TO HAVE 5.0 SQ/FT OF OPENING. HIGHER WINDOWS TO HAVE 5.70 SQ/FT. MAXIMUM HEIGHT OF AN ESCAPE WINDOW IS 44 INCHES OFF THE FLOOR. EXTERIOR WINDOW WELL TO BE A MINIMUM OF 36 INCHES BY 36 INCHES. RESIDENTIAL ENERGY STATEMENT TO THE BEST OF MY KNOWLEDGE, BELIEF, AND PROFESSIONAL JUDGEMENT THIS STRUCTURE MEETS OR EXCEEDS THE ENERGY REQUIREMENTS OF THE 2020 ENERGY CONSERVATION CODE OF NYS GENERAL NOTES: 1. DESIGNED IN ACCORDANCE WITH THE 2020 NYS RESIDENTIAL BUILDING CODE, DIMENSIONS TO, OF, AND IN EXISTING STRUCTURE SHALL BE VERIFIED IN FIELD BY CONTRACTOR. 2. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES IN DIMENSIONS BETWEEN EXISTING CONDITIONS AND / OR ARCHITECTURAL DRAWINGS AND THE STRUCTURAL DRAWINGS. 3. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. DETAILS SHOWN ARE TYPICAL, SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. 4. DIMENSION AND NOTES THAT INCLUDE THE WORD "TYPICAL" REFER TO ALL SIMILAR DETAILS UNLESS OTHERWISE STATED. 5. THE NOTES ON THIS DRAWING ARE TYPICAL UNLESS NOTED OTHERWISE. 6. BRACE BUILDING UNTIL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: ROOF DECK, CONNECTION TO EXISTING BUILDING. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING AND BRACING DURING CONSTRUCTION AND COMPLY WITH ALL APPLICABLE SAFETY REGULATIONS. 8. CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF PROPOSED DEVIATIONS OR SUBSTITUTIONS FROM DIMENSIONS, MATERIALS, OR EQUIPMENT SHOWN ON THE DRAWINGS AND MAKE ONLY THOSE DEVIATIONS OR SUBSTITUTIONS ACCEPTED BY THE ENGINEER. 9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY. 10. ALL PLUMBING, HVAC, ELECTRICAL, AND FIRE SYSTEMS ARE BY OTHERS. LOCATIONS DESIGN AND INSTALLATION OF ALL NOTED ABOVE ARE TO BE COMPLETED BY LICENSED INDIVIDUALS ACCORDING TO ALL BUILDING CODE AND THE MANUFACTURERS PRODUCT INSTALLATION INSTRUCTION. 11. ALL DOORS AND WINDOWS TO BE INSTALLED ACCORDING TO THE MANUFACTURERS PRODUCT INSTALLATION INSTRUCTION. 12. UNLESS SPECIFIED, ALL ROOM FINISHES, APPLIANCES, FIXTURES, HARDWARE, TRIM AND ARCHITECTURAL DETAILS ARE TO BE DETERMINED BY OTHERS AND INSTALLED ACCORDING TO ALL BUILDING CODES AND THE MANUFACTURERS PRODUCT INSTALLATION INSTRUCTION. 13. INSTALL 1/2" GYPSUM ON WALLS AND CEILING. INSTALL MOISTURE RESISTANT GREENBOARD GYPSUM IN ALL BATH, KITCHEN, AND OTHER WET AREAS. 14. ALL CONSTRUCTION SHALL CONFORM TO THE APPLICABLE STATE AND LOCAL BUILDING CODE REQUIREMENTS. DETAILS OF CONSTRUCTION UNLESS NOTED OTHERWISE SHALL BE PER THE 2020 RESIDENTIAL CODE OF NYS 15. CONTRACTOR SHALL PERFORM ALL MISCELLANEOUS REMOVALS, MODIFICATIONS, CONSTRUCTION AND CLEAN-UP REQUIRED TO COMPLETE THE GENERAL SCOPE OF THIS PROJECT. 16. NO SITE INSPECTIONS DURING CONSTRUCTION ARE TO BE MADE BY THIS OFFICE. CONTRACTOR TO BE RESPONSIBLE FOR MATERIALS AND WORKMANSHIP. SUBSTITUTIONS FOR MATERIALS SPECIFIED TO BE MADE WITH PERMISSION OF LOCAL BUILDING DEPARTMENT. 17. CONTRACTOR TO BE RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE BUILDING, ELECTRICAL, MECHANICAL, SANITARY AND ENERGY CONSERVATION CODES, STATE AND / OR LOCAL. 18. CONTRACTOR TO BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES AND SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 19. THE CONTRACTOR / OWNER SHALL PERFORM EXPLORATORY EVALUATION TO DETERMINE ACTUAL FIELD CONDITIONS AND NOTIFY THE ENGINEER OF HIS FINDINGS TO ALLOW FOR DESIGN CHANGES PRIOR TO ACTUAL FOUNDATION AND CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR / OWNER TO DEVELOP THE NECESSARY FOUNDATION SOIL TO SUSTAIN THE DESIGN LOADS AND TO HIRE A SOILS ENGINEER EXPERT TO INSPECT AND VERIFY SOIL CONDITIONS PRIOR TO POURING OF FOUNDATIONS. THE CONTRACTOR, BUILDER OR OWNER SHALL NOTIFY ENGINEER OF ANY UNUSUAL SITE CONDITIONS WHICH MAY EFFECT THE FOUNDATION, DRAINAGE OR STRUCTURAL MEMBERS INCLUDING REQUIREMENTS FOR ADDITIONAL DEPTH OF FOOTINGS, UNSTABLE SOIL CONDITIONS AND HIGH GROUND WATER TABLE. GENERAL NOTES CONTINUED: 20. THE CONTRACTOR / OWNER SHALL REQUEST LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO ANY DIGGING. 21. THE CONTRACTOR SHALL INDEMNIFY THE OWNER AND HIS AGENTS THROUGH ADEQUATE INSURANCE COVERAGE AGAINST ANY CLAIMS ARISING FROM INJURIES DURING CONSTRUCTION, OR FAILURE TO MAINTAIN SAFE CONDITIONS ON THE CONSTRUCTION SITE. 22. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, OWNER OR BUILDER OF THIS STRUCTURE TO NOTIFY THE ENGINEER OF ANY DEVIATION FROM THESE DRAWINGS. 23. THESE PLANS COMPLY WITH ALL THE CODES, PROVISIONS AND INTENT OF THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE PURSUANT TO ARTICLE 2 OF THE ENERGY LAW. LOCAL CODE REQUIREMENTS SHALL TAKE PRECEDENCE WHERE DISCREPANCIES OCCUR. 24. ANY ERRORS, OMISSIONS OR DISCREPANCIES IN THESE PLANS SHALL BE REPORTED IN WRITING TO THE ENGINEER BEFORE START OF CONSTRUCTION AND SHALL BE THE SOLE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 25. UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. 26. HOLD HARMLESS THE ENGINEER, THE CONSTRUCTION MANAGER, THE OWNER AND THEIR AGENTS LOSS, DAMAGE, LIABILITY OR ANY EXPENSE ARISING IN ANY MANNER BY THE INDEPENDENT CONTRACTOR OR THEIR RESPECTIVE EMPLOYEES, INCLUDING SHALL BE THE STATE SCAFFOLDING ACT. 27. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR COMPLETED WORK. 28. CONTRACTOR IS TO FOLLOW ALL MANUFACTURERS PRODUCT INSTALLATION AND INSTRUCTION. 29. WHENEVER A VALUE OR SIZE IS IN CONFLICT THE MORE STRINGENT VALUE OR SIZE WILL APPLY. NAILING SCHEDULE: PER R602.3(1) TOP PLATE TO STUD (END NAIL)..............................2-16D COMMON STUD TO SOLE PLATE (END NAIL)............................2-16D COMMON STUD TO SOLE PLATE (TOE NAIL)............................4-8D COMMON OR 3-16D BOX DOUBLE TO PLATES...................................................10D BOX @ 12" OC DBL TOP PLATE LAP SPLICE......................................8-16D COMMON TOP PLATES LAPS (INTERSECTION)........................3-10D BOX SOLE PLATE TO JOISTS OR BLOCKING...................16D COMMON @ 16" OC CEILING JOISTS TO TOP PLATE (TOE-NAIL)............3-8D COMMON CEILING JOISTS OVER PARTITION...........................4-10D BOX CEILING JOISTS TO PARALLEL RAFTER..................PER R802.5.1(9) RAFTER TO TOP PLATE (TOE-NAIL)..........................3-16D BOX 1X BRACE TO STUD/PLATE........................................2-8D COMMON JOISTS TO SILL PLATE (TOE-NAIL)...........................3-8D COMMON RAFTER TO RIDGE, HIP OR VALLEY (TOE-NAIL).....4-16D BOX RAFTER TO RIDGE, HIP OR VALLEY (END-NAIL).....3-16D BOX RAFTER-TIES TO RAFTER..........................................4-8D BOX SUBFLOOR TO FLOOR JOISTS..................................6D COMMON @ 6"OC EDGE 12" OC FIELD WALL SHEATHING TO STUD......................................6D COMMON @ 6" OC EDGE 12" OC FIELD ROOF SHEATHING TO RAFTER/TRUSS....................8D COMMON @ 6" OC EDGE 12" OC FIELD ENERGY NOTES: 1. CAULK ALL EXTERIOR TOE PLATES WITH LATEX CAULK. 2. CAULK ALL WIRE AND PIPE HOLES WHERE THEY PENETRATE ALL UPPER AND LOWER EXTERIOR PLATES. 3. SEAL ALL JOINTS IN HVAC DUCTS w/ LEAKAGE NO MORE THAN 3%. 3" FIBER MESH TAPE SHOULD BE USED ON ALL COLLAR TO PLENUM CONNECTIONS AND ALL GAPS THAT ARE 1/4" OR WIDER. INSULATE DUCTS WITH R-6.5 OR GREATER. 4. FOAM INSULATE BETWEEN ALL EXTERIOR WINDOW AND DOOR EDGES AND ROUGH OPENING FRAME. USE NON- EXPANDING FOAM (W.R. GRACE/ POLY-CELL ONE OR EQUAL). 5. PROVIDE BACK DRAFT DAMPER ON KITCHEN HOOD VENT, DRYER VENT, AND BATHROOM VENT. 6. INSULATE ALL HOT WATER PIPES. INSTALL WRAP KIT ON WATER HEATER. BATHROOM NOTES: 1. THE CENTER LINE OF WATER CLOSET SHALL BE NOT LESS THAN 15" FROM ADJACENT WALLS / PARTITIONS OR 15" FROM A TUB. A MINIMUM 21" CLEARANCE IS REQUIRED IN FRONT OF WATER CLOSETS (PER CODE). 2. SHOWER COMPARTMENTS SHALL HAVE AT LEAST 1,024 SQ. IN. OF FLOOR AREA AND BE OF SUFFICIENT SIZE TO ENCOMPASS A CIRCLE WITH DIAMETER NOT LESS THAN 30" (PER CODE). 3. THE WALL AREA ABOVE BUILT-IN TUBS HAVING SHOWER HEADS AND IN SHOWER COMPARTEMENTS SHALL BE FINISHED WITH A SMOOTH, HARD, AND NON-ABSORBENT SURFACE TO A HEIGHT OF NOT LESS THAN 6' ABOVE THE FLOOR. IF GYPSUM BOARD IS USED AS A BASE OR BACKER BOARD FOR ADHESIVE APPLICATION OF TILE OR SIMILAR MATERIAL, IT SHALL BE A TYPE MANUFACTURED FOR THAT USE (PER CODE). ATTIC NOTES: 1. ATTIC SPACES HAVING 30" OR GREATER VERTICAL CLEAR HEIGHT REQUIRE A MINIMUM 22"x30" ATTIC ACCESS (PER CODE) 2. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. THE NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE SPACE OR 1/300, PROVIDED AT LEAST 50% AND NOT MORE THAN 80% OF THE REQUIRED VENTS ARE IN THE UPPER PORTION OF THE AREA AT LEAST 36" ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS OR THE VENTILATION MAY BE 1/300 IF A 1 PERM VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF THE CEILING (PER CODE). PRESCRIPTIVE METHOD SARATOGA COUNTY, NY ENERGY STATEMENT = PRESCRIPTIVE FOR CLIMATE ZONE 5A FENESTRATION MAXIMUM U-FACTOR = 0.30 CEILING INSULATION = R-49 OR EQUIVALENT U FACTOR 0.026 WOOD FRAME WALL INSULATION = R-20 CAVITY OR R-13 + R-5 CONTINOUS OR EQUIVALENT U FACTOR 0.060 FLOOR INSULATION = R-30 OR INSULATION SUFFICIENT TO FILL FRAMING CAVITY (MIN R-19) OR EQUIVALENT U FACTOR 0.033 BASEMENT WALL INSULATION = R-15 CONTINUOUS OR R-19 CAVITY OR EQUIVALENT U FACTOR 0.050 SLAB INSULATION = R-10 2ft DEPTH CRAWL SPACE WALL INSULATION = R-15 CONTINUOUS OR R-19 CAVITY OR EQUIVALENT U FACTOR 0.055 R VALUE = 1 / U VALUE U VALUE = 1 / R VALUE INDEX -G1 TITLE PAGE & NOTES -G2 NOTES -F1 EXISTING & NEW FOUNDATION PLAN A1 EXISTING & NEW FIRST FLOOR PLAN A2 EXISTING & NEW 2ND FLOOR PLAN A3 ELEVATIONS & 3D VIEWS A4 BUILDING SECTION A5 BUILDING SECTION P1 PLOT PLAN SECOND FLOOR ADDITION / RENOVATION HOMEOWNER: MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 No . De s c r i p t i o n Da t e E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 0 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Notes 25-03-017 06-16-25 SK RN ADDITION / RENOVATION -G2 STAIR NOTES: 1. R311.7.1: WIDTH: STAIRWAYS SHALL NOT BE LESS THAN 36" IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5" ON EITHER SIDE OF THE STAIRWAY AND THE MINIMUM CLEAR WIDTH OF THE STAIRWAY AT AND BELOW THE HANDRAIL HEIGHT, INCLUDING TREADS AND LANDINGS, SHALL NOT BE LESS THAN 31.5" WHERE A HANDRAIL IS INSTALLED ON ONE SIDE AND 27" WHERE HANDRAILS ARE PROVIDED ON BOTH SIDES. EXCEPTION: THE WIDTH OF SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH SECTION R311.7.10.1 2. R311.7.2: HEADROOM: THE MINIMUM HEADROOM IN ALL PARTS OF THE STAIRWAY SHALL NOT BE LESS THAN 6'-8" MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR PLATFORM. 3. R311.7.5.1: THE MAXIMUM RISER HEIGHT SHALL BE 8-1/4". THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEEDED THE SMALLEST BY MORE THAN 3/8". OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENINGS LOCATED MORE THAN 30" AS MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A 4" DIAMETER SPHERE. EXCEPTION 1: THE OPENING BETWEEN ADJACENT TREADS IS NOT LIMITED ON SPIRAL STAIRWAYS. EXCEPTION 2: THE RISER HEIGHT OF SPIRAL STAIRWAYS SHALL BE IN ACCORDANCE WITH R311.7.10.1 4. R311.7.5.2: THE MINIMUM TREAD DEPTH SHALL BE 9". THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8". 5. R311.7.5.2.1: WINDER TREADS: WINDER TREADS SHALL HAVE A TREAD DEPTH OF NOT LESS THAN 10" MEASURED BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AT THE INTERSECTIONS WITH THE WALKLINE. WINDER TREADS SHALL HAVE A TREAD DEPTH OF NOT LESS THAN 6" AT ANY POINT WITHIN THE CLEAR WIDTH OF THE STAIR. THE LARGEST TREAD DEPTH AT THE WALKLINE SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8". 6. R311.7.5.3: NOSING: THE RADIUS OF CURVATURE AT THE NOSING SHALL BE NO GREATER THAN 9/16". A NOSING NOT LESS THAN 3/4" BUT NOT MORE THAN 1-1/4" SHALL BE PROVIDED ON STAIRWAYS WITH SOLID RISERS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8". BEVELING OF NOSING SHALL NOT EXCEED 1/2". EXCEPTION: A NOSING IS NOT REQUIRED WHERE THE TREAD DEPTH IS A MINIMUM OF 11". STAIR NOTES CONTINUED: 1. R311.7.6: LANDINGS: THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY. EXCEPTION: A FLOOR OR LANDING IS NOT REQUIRED AT THE TOP OF AN INTERIOR FLIGHT OF STAIRS, INCLUDING STAIRS IN AN ENCLOSED GARAGE, PROVIDED A DOOR DOES NOT SWING OVER THE STAIRS. EXCEPTION (R11.3.2): A TOP LANDING IS NOT REQUIRED WHERE A STAIRWAY OF NOT MORE THAN TWO RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, PROVIDED THAT THE DOOR DOES NOT SWING OVER THE STAIRWAY, FOR OTHER THAN THE REQUIRED EGRESS DOOR. 2. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE WIDTH OF THE STAIRWAY SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. 3. R311.7.8: HANDRAILS: HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT OF STAIRS. HAVING 4 OR MORE RISERS. 4. R311.7.8.1: HEIGHT: HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, OR FINISHED SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES. 5. R311.7.8.2: CONTINUITY: HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAILS. 6. R311.7.8.3: GRIP SIZE: REQUIRED HANDRAILS SHALL BE OF TYPE 1 OR TYPE 2 AS SPECIFIED IN THE 2020 RCNYS, OR OF EQUIVALENT GRASPABILITY. 7. R311.7.9: ILLUMINATION: ALL STAIRS SHALL BE PROVIDED WITH ILLUMINATION IN ACCORDANCE WITH SECTION R303.7. 8. R311.7.10.1: SPIRAL STAIRWAYS: SPIRAL STAIRWAYS ARE PERMITTED, PROVIDED THAT THE CLEAR WIDTH AT AND BELOW THE HANDRAIL IS NOT LESS THAN 26" AND THE WALKLINE RADIUS IS NOT GREATER THAN 24-1/2". EACH TREAD SHALL HAVE A DEPTH OF NOT LESS THAN 6-3/4" AT THE WALKLINE. ALL TREADS SHALL BE IDENTICAL, AND THE RISE SHALL BE NOR MORE THAN 9-1/2". HEADROOM SHALL BE NOT LESS THAN 6'-6". FOUNDATION NOTES: 1. FOOTINGS ARE TO BEAR ON UNDISTURBED LEVEL SOIL DEVOID OF ANY ORGANIC MATERIALS AND STEPPED AS REQUIRED TO MAINTAIN THE REQUIRED DEPTH BELOW THE FINAL GRADE. 2. SOIL BEARING PRESSURE ASSUMED TO BE 2000 PSF. 3. ANY FILL UNDER GRADE SUPPORTED SLABS TO BE A MINIMUM OF 4" GRANULAR MATERIAL COMPACTED TO 95%. 4. CONCRETE: BASEMENT WALLS & FOUNDATIONS NOT EXPOSED TO WEATHER: 3000 PSI BASEMENT & INTERIOR SLABS ON GRADE: 3000 PSI BASEMENT WALLS & FOUNDATIONS EXPOSED TO WEATHER: 3000 PSI GARAGE SLABS: 3500 PSI 5. CONCRETE SIDEWALKS TO HAVE TOOLED JOINTS AT 5' O.C. (MINIMUM) 6. REINFORCED STEEL TO BE A-615 GRADE 60. WELDED MESH WIRE TO BE A-185. 7. COVER ENTIRE CRAWLSPACE WITH 6 MILL BLACK "VISQUEEN" AND EXTEND UP FOUNDATION WALLS TO P.T. MUDSILL. 8. PROVIDE A MINIMUM OF 1 SQ. FT OF VENTILATION AREA FOR EACH 150 SF OF CRAWLSPACE AREA. VENTS ARE TO BE CLOSABLE WITH OPENINGS IN CORROSIVE RESISTANT SCREEN. POST NOTICE RE: OPENING VENTS ARE FOR ELECTRICAL PANEL. 9. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED OR PROTECTED WITH #55 ROLL ROOFING. 10. PROVIDE CRAWLSPACE DRAIN AS PER CODE. 11. DAMP PROOF BASEMENT WALL BEFORE BACKFILLING, PROVIDING A 4" PERFORATED DRAIN TILE BELOW THE TOP OF THE FOOTING. 12. DAY STRENGTH AND NOT BEFORE STRUCTURAL FLOOR FRAMING (INCLUDING SUB-FLOOR) IS IN PLACE (FRAMING MUST BE FULLY NAILED AND ANCHORED). 13. CONCRETE SHALL BE AIR ENTRAINED AND SHALL BE PLACED IN ACCORDANCE WITH ACI 318 LATEST EDITION. 14. FORMS SHALL CONFORM TO THE SHAPE, LINES GRADE AND DIMENSIONS INDICATED ON THE DRAWINGS. THEY SHALL BE SUBSTANTIAL AND SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF MORTAR, AND SHALL NOT DEFLECT UNDER THE WEIGHT OF THE WET CONCRETE OR CONSTRUCTION LOADS. THEY SHALL BE PROPERLY BRACED OR TIED TOGETHER SO AS TO MAINTAIN POSITION AND SHAPE, AND INSURE THE SAFETY OF WORKMEN AND PASSERBY. 15. IF APPLICABLE, CONCRETE POUR FOR THE HOUSE FOUNDATION AND THE GARAGE FOUNDATION ARE TO BE A CONTINUOUS POUR WHERE MEET. 16. CONCRETE CONSTRUCTION JOINTS ARE TO BE INSTALLED EVERY 100' MAXIMUM AROUND THE BASEMENT WALL PERIMETER TO AVOID WALL CRACKS. PLACING CONCRETE: 1. PLACING CONCRETE BEFORE INITIAL SET HAS OCCURRED, AND IN NO EVENT AFTER IT HAS CONTAINED ITS WATER CONTENT FOR MORE THAN ONE HOUR. 2. PLACE ALL CONCRETE ON CLEAN, DAMP SURFACES, FREE FROM WATER, OR UPON PROPERLY CONSOLIDATED FILLS, BUT NEVER UPON SOFT MUD, DRY POROUS EARTH, OR FROZEN GROUND. 3. DEPOSIT CONCRETE CONTINUOUSLY AND AS RAPIDLY AS PRACTICAL UNTIL THE UNIT OF OPERATION IS COMPLETED. 4. CONSOLIDATE ALL CONCRETE BY VIBRATION SO THAT THE CONCRETE IS THOROUGHLY WORKED AROUND THE REINFORCEMENT, AROUND IMBEDDED ITEMS, AND INTO CORNERS OF FORMS, ELIMINATING ALL AIR OR STONE POCKETS WHICH MAY CAUSE HONEY-COMBING, PITTING, OR PLANES OF WEAKNESS. 5. USE MECHANICAL VIBRATORS WITH A MINIMUM FREQUENCY OF 7,000 REVOLUTIONS PER MINUTE, OPERATED BY COMPETENT WORKMEN. USE OF VIBRATORS AT MANY POINTS FROM 18 TO 30 INCHES APART FOR A 5 TO 10 SECOND DURATION. KEEP A SPARE VIBRATOR ON THE JOB DURING ALL CONCRETE PLACING OPERATIONS. 6. EXERCISE CARE IN PLACEMENT OF CONCRETE FOR SLABS OR GRADE OVER A VAPOR BARRIER. AVOID PUNCTURING OR TEARING VAPOR BARRIER DURING TRANSPORTATION AND PLACEMENT. 7. THE PLACING OF CONCRETE SHALL BE CARRIED ON CONTINUOUSLY BETWEEN CONSTRUCTION JOINTS SHOWN ON THE DRAWINGS. IF FOR ANY REASON IT SHALL BECOME NECESSARY TO STOP THE PLACING OF CONCRETE AT PLACES OTHER THAN THOSE INDICATED ON THE DRAWINGS, SUCH PLACES SHALL HAVE THE APPROVAL OF THE ENGINEER AND THE MANNER OF MAKING THE JOINT SHALL BE APPROVED. EXTRA REINFORCING MAY BE REQUIRED IF ADDITIONAL CONSTRUCTION JOINTS ARE USED. 8. PROVIDE ADEQUATE PROTECTION AGAINST RAIN, SLEET, AND SNOW BEFORE AND DURING PLACEMENT AND FINISHING OF CONCRETE. PROVIDE ADEQUATE PROTECTIVE MEASURES TO MAINTAIN THE TEMPERATURE OF THE CONCRETE AS SPECIFIED. 9. TIE HOLES LEFT BY WITHDRAWAL OF RODS OR THE HOLES LEFT BY REMOVAL OF END OF TIES SHALL BE FILLED WITH MORTAR. FOR HOLES PASSING ENTIRELY THROUGHOUT THE WALL, A PLUNGER TYPE GREASE GUN OR OTHER DEVICE SHALL BE USED TO FORCE THE MORTAR THROUGH THE WALL STARTING AT THE BACK FACE. 10. ANY CONCRETE WORK NOT FORMED AS SHOWN ON THE PLANS OR FOR ANY REASON IS OUT OF ALIGNMENT OR LEVEL OR SHOWS A DEFECTIVE SURFACE SHALL BE CONSIDERED AS NOT CONFORMING WITH THE INTENT OF THESE SPECIFICATIONS AND SHALL BE REMOVED FROM THE JOB BY THE CONTRACTOR AT HIS EXPENSE UNLESS THE ENGINEER GRANTS PERMISSION TO PATCH THE DEFECTIVE AREA WHICH SHALL BE DONE IN ACCORDANCE WITH THE FOLLOWING PROCEDURE. PERMISSION TO PATCH ANY SUCH AREA SHALL NOT BE CONSIDERED A WAIVER OF THE ENGINEERS RIGHT TO REQUIRE COMPLETE REMOVAL OF THE DEFECTIVE WORK IF THE PATCHING DOES NOT, IN HIS OPINION, SATISFACTORILY RESTORE THE QUALITY AND APPEARANCE OF THE SURFACE. 11. IF APPLICABLE THE COMPRESSIVE STRENGTH OF EXISTING CONCRETE SLAB (f ' c)=2500 PSI MINIMUM. 12. STEPPED FOOTING TO BE INSTALLED PER SITE REQUIREMENTS. MINIMUM 24 INCHES DOWN AND 48 INCHES OVER. STEEL REINFORCEMENT: 1. ALL REINFORCING STEEL SHALL BE MANUFACTURED FROM NEW BILLET STEEL, GRADE 60, DEFORMED BARS, IN ACCORD WITH STANDARD SPECIFICATIONS ASTM A 15 LATEST EDITION. 2. STEEL REINFORCEMENT SHALL CONSIST OF FURNISHING AND PLACING BAR STEEL OR STEEL FABRIC REINFORCEMENTS AS SHOWN ON THE PLANS AND REQUIRED BY THE CONTRACT. 3. REINFORCEMENT IN FLOOR SLABS PLACED ON EARTH THE REINFORCING SHALL BE SUPPORTED BY MASONRY BLOCKING OF PROPER HEIGHT TO INSURE THAT THE REINFORCING MATERIAL WILL BE PLACED IN THE CENTER OF SUCH SLABS. 4. WHERE WIRE MESH IS USED IN FLOOR SLABS, IT SHALL BE 6”BY 6”/ #6 X #6 GAUGE WELDED WIRE. ALL MESH SHALL BE LAPPED A MINIMUM OF 6 INCHES UNLESS THE PLANS SHOW SPECIFIC SPACING. 5. THE MINIMUM CLEAR SPACING BETWEEN THE EDGE OF THE BARS AND THE EXTERIOR SURFACE OF ALL POURED CONCRETE SHALL BE 1-1/2 TIMES THE MAXIMUM NOMINAL SIZE OF THE CONCRETE AGGREGATE. HOWEVER CLEAR SPACING SHALL NOT BE LESS THAN 3” WHEN THE CONCRETE IS CAST AGAINST EARTH. IF FOR ANY REASON, REINFORCING STEEL HAS TO BE PLACED CLOSER THAN 1-1/2 INCHES TO ANY FORM, THE CONTRACTOR SHALL OBTAIN THE ENGINEER'S APPROVAL OF SUCH PLACEMENT BEFORE THE POUR IS MADE. GUARDS: 1. R312.1.1 WHERE REQUIRED: GUARDS SHALL BE PROVIDED FOR THOSE PORTIONS OF OPEN-SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 MM) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD. 2. R312.1.2 HEIGHT: REQUIRED GUARDS AT OPEN-SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE OR THE LINE CONNECTING THE NOSINGS. EXCEPTIONS: GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT OF NOT LESS THAN 34 INCHES (864 MM) MEASURED VERTICALLY FROM A LINE CONNECTING THE NOSINGS. WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM) AS MEASURED VERTICALLY FROM A LINE CONNECTING THE NOSINGS. 3. R312.1.3: OPENING LIMITATIONS: REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4" IN DIAMETER. EXCEPTIONS: a) THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF STAIRS FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD SHALL NOT ALLOW THE PASSAGE OF A SPHERE 6" IN DIAMETER. b) GUARDS ON THE OPEN SIDE OF STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4-3/8" IN DIAMETER. No . De s c r i p t i o n Da t e *ALL DIMENSIONS ARE APPROXIMATE WITHIN REASONABLE INDUSTRY TOLERANCES UP FIRST FLOOR FRAMING: 2x6 @ 22" O.C. CMU BLOCK OVER LOWER FIELDSTONE BRICK CHIMNEY (TYP) UNKNOWN CONNECTION: ASSSUMED MOTAR OR SEALANT LOWER FIELDSTONE (ACCESS TO CRAWL) FI E L D S T O N E FI E L D S T O N E CMU BLOCK FULL HGT 2' - 5"2' - 6" BASEMENT 6'-3" CEILING HGT FULL HGT FLOOR JOISTS: UNKNOWN SIZE, ASSUMED DIRECTION CRAWL SPACE UNKNOWN CEILING HGT CRAWL SPACE FLOOR JOISTS: 2x8 @ 16" O.C. DECK JOISTS: PT 2x6 @ 16" O.C. DROPPED BEAM: PT (2) 2x8 12" CONCRETE PIER 48" DEPTH, 2" ABOVE GRADE. * OPTIONAL STEEL HELICAL PIER (TYP) CONCRETE FND WALL EXISTING EX I S T I N G EX I S T I N G A3 1 A3 2 UP FIRST FLOOR FRAMING EXISTING BASEMENT EXISTING CRAWL SPACE EXISTING CRAWL SPACE EXISTING FLOOR JOISTS A33 1 A5 1 A4 SOLID BEARING FROM ABOVE TO T.O. EXISTING FOUNDATION WALL EXISTING DECK JOISTS EXISTING FLOOR JOISTS: UNKNOWN SIZE, ASSUMED DIRECTION EXISTING LOWER FIELDSTONE (ACCESS TO CRAWL) EX I S T I N G F I E L D S T O N E EX I S T I N G F I E L D S T O N E EXISTING EX I S T I N G EX I S T I N G SOLID BEARING FROM ABOVE TO T.O. EXISTING FOUNDATION WALL E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 3/16" = 1'-0" 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 0 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Existing & New Foundation Plan 25-03-017 06-16-25 SK RN ADDITION / RENOVATION -F1 3/16" = 1'-0"1 EXISTING FOUNDATION PLAN No . De s c r i p t i o n Da t e 3/16" = 1'-0"2 EXISTING FOUNDATION PLAN W/ NEW D W RE F . DW RE F . DW CL KITCHEN 8'-2 1/2" CEILING EXISTING FLOOR JOISTS ASSUMED 2x8 EXISTING FLOOR JOISTS ASSUMED 2x6 FLOOR JOISTS: 2x8 @ 16" O.C. RAFTERS: 2x6 @ 16" O.C. (OPTIONAL CEILING JOISTS: 2x4 @ 16" O.C. & SOFFIT COVERING) DROPPED BEAM: (2) 2x8 EXTERIOR REAR ADDITION WALLS: (TYP) ASSUMED 2x4 STUDS, 5" TOTAL WALL THICKNESS SHED ROOF RAFTERS & CEILING JOISTS 39 " x 3 4 " C S M T 44 " S I L L EXTERIOR WALLS: (TYP) ASSUMED 2x4 R.C. STUDS, 5-1/2" TOTAL WALL THICKNESS INTERIOR WALLS: (TYP) ASSUMED 2x4 R.C. STUDS, 5" TOTAL WALL THICKNESS CANTILEVER ABOVE CHIMNEY ASSUMED GYP OVER BRICK BATH 7'-3 5/8" CEILING 22 " x 2 2 " F I X 56 " S I L L 7'-7 1/4" CEILING BED RM N/A DN 28 " x 8 0 " 9' - 9 1 / 4 " 2' - 1"4' - 7" 5' - 1 1 1 / 2 " MUD 8'-2 1/2" CEILING 1.5" STEP DN3' - 1 " * BUILDER & HOMEOWNER TO COORIDINATE SALVAGING OF MATERIALS, APPLIANCES, FIXTURES ECT. EXISTING INSULATION NOT SHOWN (TYP) *ALL DIMENSIONS ARE APPROXIMATE WITHIN REASONABLE INDUSTRY TOLERANCES 30 " x 8 0 " 30 " x 8 0 " 60 " x 8 0 " 30"x80" SHELVING 30 " x 8 0 " DEMO RAFTERS ONLY 5' - 9 " 11' - 3" LINE OF SLOPED CEILING 85.25" HGT WALL 23 " x 3 3 " D H 45 " S I L L SHED ROOF OVERHANG DEMO 1.5"+/-STEP DN DESIGN INTENT:EXISTING BATH CEILING TO REMAIN A3 1 A3 2 CL EXISTING KITCHEN EXISTING FLOOR JOISTS EXISTING FLOOR JOISTS EXISTING BATH EXISTING BED RM DN EX I S T I N G MU D 30"x80" A33 EXISTING RAFTERS 2ND FLOOR FRAMING: CONTINUOUS 2x8 @ 16" O.C. EXISTING FLOOR JOISTS 1 A5 1 A4 (2) 2x4 MIN. ALIGN W/ SOLID BEARING FROM ABOVE SOLID BLOCK ABOVE EXISTING WALL DOUBLE TOP PLATE. REFER TO SECTION VIEWS 11' - 3" (3) 2x4 MIN. ALIGN W/ SOLID BEARING FROM ABOVE (2) 2x4 MIN. ALIGN W/ SOLID BEARING FROM ABOVE 12' - 0" 10 ' - 5 3 / 4 " 16 ' - 3 1 / 4 " E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 3/16" = 1'-0" 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 1 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Existing & New First Floor Plan 25-03-017 06-16-25 SK RN ADDITION / RENOVATION A1 No . De s c r i p t i o n Da t e 3/16" = 1'-0"1 EXISTING FIRST FLOOR PLAN W/ DEMO 3/16" = 1'-0"2 EXISTING FIRST FLOOR PLAN W/ NEW 32"x80" 28"x80"3' - 6 " 6' - 3" RAFTERS: 2x12 @ 16" O.C. CEILING JOISTS: 2x4 @ 16" O.C. MA S T E R BA T H EXISTING INSULATION NOT SHOWN UNKNOWN MASTER CL 5' - 6 1 / 2 " 6' - 6 1 / 2 " CE I L I N G DROPPED BEAM / HDR COLUMN STEP DN 6" LINE OF FIRST FLOOR BELOW ROOF SYSTEM 56" KNEE WALL 5' - 0" 56" KNEE WALL 7'-8" CEILING (SLOPED)(SLOPED) 20"x32" DH 43" SILL 5' - 5 1/2" 2' - 9 1 / 4 " CL 3' - 0"1' - 6 1 / 2 " 5' - 10 1/2"24"x70"32"x80" 26"x36" DH 36" SILL ASSUMED GYP OVER BRICK ROOF SYSTEM: ASSUMED 2x4 R.C. RAFTERS W/ SISTERED 2x6 *ALL DIMENSIONS ARE APPROXIMATE WITHIN REASONABLE INDUSTRY TOLERANCES * BUILDER & HOMEOWNER TO COORIDINATE SALVAGING OF MATERIALS, APPLIANCES, FIXTURES ECT. FIRST FLOOR SHED ROOF BELOW DEMO ROOF ONLY DEMO DEMO DEMO DEMO DEMO DEMO DEMO 11' - 3" 9' - 1 0 1 / 4 " + / - DEMO EXISTING MASTER SUITE 7'-2" CEILING A3 1 A3 2 EXISTING RAFTERS EX I S T I N G MA S T E R BA T H NEW WIC 7'-9" CEILING HGT EXISTING STEP DN 6" EXISTING ROOF SYSTEM *NEW DIMENSIONS ARE FACE OF NEW STUD & / OR FACE OF EXISTING GYPSUM A33 CO V E R E D CO F F E E DE C K 32"x80" CASED OPENING HEADER: (2) 2x8 MININFILL IN KIND EXISTING MASTER SUITE 7'-2" CEILING 1 A5 DROPPED BEAM: (2) 2x8 W/ (2) 2x4 SOLID BEARING EA. END OR: OPTIONAL 2x6 @ 16" O.C. WALL W/ SOLID BLOCKING IN FLOOR JOISTS BELOW ROOF RAFTERS: 2x12 @ 16" O.C. CEILING JOISTS: 2x6 @ 16" O.C. 1 A4 BEAM: PT (2) 2x8 FINISH DET. BY OWNER(S) BEAM: NON-BEARING: MATCH ADJACENT BEAM REVEAL 7' - 0" ALIGN NEW 2ND FLOOR WALL EXTENTS W/ EXISTING FIRST FLOOR WALL EXTENTS BELOW (TYP) 36" HEIGHT GUARD. STYLE & FINISH DET. BY OWNER(S) 7' - 11"4' - 1" 12' - 0" 15 ' - 1 0 " HEADER HEIGHT TO MATCH ADJACENT EXISTING MASTER BATH WINDOW DECK FLOOR CONSTRUCTION: -DECKING: COMPOSITE, PT, OR NATURAL RESISTANCE TO DECAY -WATERPROOF MEMBRANE -PT 3/4" PLYWOOD -FLOOR JOISTS PER PLAN A 1 SOLID BEARING: (2) 2x6 3' - 11 1/2"3' - 11 1/2" 2' - 3" 10 ' - 1 3 / 4 " 6' - 1 1 / 2 " 16 ' - 3 1 / 4 " 10 ' - 5 3 / 4 " 11' - 1" 9' - 8 1 / 4 " SOLID BEARING: (2) 2x6 SOLID BEARING: (2) 2x4 MIN * ALL EXTERIOR WALL HEADERS = (2) 2x10 UNLESS NOTED DIFFERENT. ALL INTERIOR NON-BEARING WALL HEADERS = (2) 2x6 UNLESS NOTED DIFFERENT * DOUBLE TRIMMER STUDS REQUIRED FOR OPENINGS 48" OR GREATER IN EXTERIOR & / OR BEARING WALLS UNLESS NOTED DIFFERENT NOTE: SECURE ALL FLUSH BEAM PLIES TOGETHER W/ (2) ROWS OF SIMPSON SDS25312 STRUCTURAL SCREWS @ 24" O.C. STAGGERED SMOKE DETECTOR W/ BATTERY BACK-UP, HARDWIRED AND INTERCONNECTED ON SEPARATE CURCUIT. S SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: IN EACH SLEEPING ROOM. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. EXTERIOR WALL: (TYP) -2x6 STUD 16" O.C. -DOUBLE TOP PLATE -SINGLE BOTTOM PLATE (PRESSURE TREATED IF CONTACT W / CONCRETE) -HDR=(2) 2x10 W / CRIPPLE STUDS UNLESS NOTED DIFFERENT -HOUSE WRAP W / SEAMS OVERLAPPED AND SEALED -SIDING PER PLAN -7/16" ZIP-IT OR EQUAL SHEATHING -OPTIONAL 1/2" GYPSUM WALLS & CEILING -INSULATION PER PLAN -FINISH MATERIALS BY OTHERS * DOUBLE TRIMMER STUDS REQUIRED FOR OPENINGS 48" OR GREATER IN EXTERIOR & / OR BEARING WALLS UNLESS NOTED DIFFERENT MIN ATTIC ACCESS 22"x30". LOCATION SHOWN MAY VARYS HEADER: (2) 2x10 HEADER: (2) 2x6 3' - 10 1/4" EXISTING ROOF BELOW POST: PT 6x6 W/ SIMPSON STRONG-TIE POST BASE ABA66Z OR SIMILAR. ATTACH POST TO BEAM W/ LPC6Z POST CAPS OR NOTCHED IN POSTS W/ (2) 1/2"⌀THRU-BOLTS W/ WASHERS. POST CLADDING FINISH DET. BY OTHERS RIDGE BEAM: (1) 1.75"x14" 2.0E LVL SOLID BEARING @ END: (2) 2x6 SOLID BEARING @ END: (2) 2x4 MIN E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 3/16" = 1'-0" 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 1 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Existing & New Second Floor Plan 25-03-017 06-16-25 SK RN ADDITION / RENOVATION A2 No . De s c r i p t i o n Da t e 3/16" = 1'-0"1 EXISTING SECOND FLOOR PLAN W/ DEMO 3/16" = 1'-0"2 EXISTING SECOND FLOOR PLAN W/ NEW Exterior Door Schedule Type Mark Count Width Height Description 1 1 2' - 8" 6' - 8" ANDERSEN FWH2968, INSWING PATIO, FULL LIGHT Exterior Window Schedule Type Mark Count Rough Opening Type Manufacturer Model Glazing CommentsWidth Height Type A 1 2' - 2 1/8" 3' - 0 7/8" Window-Double-Hung ANDERSEN TW20210 LOW-E WINDOW GLAZING MIN 24" A.F.F. WINDOW & DOOR NOTES: 1. MANUFACTURER IS SUBJECT TO CHANGE BY OWNER(S). ANY CHANGES ARE TO BE EQUIVALENT. 2. MATERIALS & FINISHES TO BE DETERMINED BY OWNER(S) & MAY VARY FROM SHOWN ON PLANS. 3. GRILL PATTERNS ARE DETERMINED BY OWNER(S) & MAY VARY FROM SHOWN ON PLANS. 4. ACTIVE PANEL OPEN DIRECTION TO BE DETERMINED BY OWNER(S) & MAY VARY FROM SHOWN ON PLANS. 5. MIN SILL HEIGHT TO BE 18". IF LESS THAN 18", GLAZING TO BE TEMPERED. 6. BUILDER TO VERIFY ROUGH OPENING SIZES W/ MANUFACTURER PRIOR TO FRAMING. 7. SECOND FLOOR WINDOWS 24" MIN SILL HEIGHT. VINYL, WOOD, OR COMPOSITE SIDING DETERMINED BY OWNER (TYP) ASPHALT SHINGLES DETERMINED BY OWNER(S) (TYP) EXISTING (TYP) NEW (TYP) 6.79 +/- VINYL, WOOD, OR COMPOSITE SIDING DETERMINED BY OWNER (TYP) EXISTING (TYP) NEW (TYP) EXTERIOR ARCHITECTURAL FINISHES, DETAILING, COLORS, & STYLES ARE TO BE DETERMINED BY OWNER(S). SHOWN MAY BE SUBJECT TO CHANGE (TYP) E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D As indicated 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 3 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Elevations & 3d Views 25-03-017 06-16-25 SK RN ADDITION / RENOVATION A3 3/16" = 1'-0"2 SIDE ELEVATION A 3/16" = 1'-0"1 REAR ELEVATION No . De s c r i p t i o n Da t e 1/4" = 1'-0"3 SIDE ELEVATION B 4 3D VIEW 1 5 3D VIEW 2 T.O. Existing Bedroom First Floor 0' -0" T.O. New Roof 20' -6 1/8" T.O. Existing Basement Slab -6' -11" T.O. Existing Grade -1' -5" T.O. Existing Master Suite Wall 2 16' -1" EXISTING BATH EXISTING BED RM EX I S T I N G B A S E M E N T EX I S T I N G CR A W L S P A C E UN K N O W N CE I L I N G H G T NEW WIC EX I S T I N G M A S T E R S U I T E EX I S T I N G K I T C H E N 8' - 2 1 / 2 " 6' - 3 " (EXISTING BASEMENT TREADS & RISERS NOT APPLICABLE TO JOB SCOPE & NOT SHOWN) 7' - 2 " 7' - 7 1 / 4 " 7' - 1 0 " 6" O.H. NEW TO MATCH 15' - 10" * EXISTING INSULATION NOT SHOWN (TYP) NEW (TYP) EXISTING (TYP)7' - 3 5 / 8 " DESIGN INTENT:EXISTING BATH CEILING TO REMAIN SOLID BLOCK ABOVE EXISTING DOUBLE TOP PLATE / CEILING T.O. New WIC Wall 2 16' -2" T.O. Existing Bath Floor -0' -1 3/4" T.O. Existing Bath Wall 1 7' -2 3/8" T.O. Existing Bedroom Wall 1 7' -8" T.O. Existing WIC Second Floor 8' -4" T.O. Existing Master Suite Floor 8' -10 1/2" FLOOR JOISTS PER PLAN * ANY WOOD EXPOSED TO EXTERIOR ELEMENTS IS TO BE PRESSURE TREATED, COMPOSITE, WOOD SPECIES OF NATURAL RESISTANCE TO DECAY, STAINED, SEALED, PAINTED, OR WRAPPED W / VINYL OR NON CORROSIVE METAL EXTERIOR WALL: (TYP) -2x6 STUD 16" O.C. -DOUBLE TOP PLATE -SINGLE BOTTOM PLATE (PRESSURE TREATED IF CONTACT W / CONCRETE) -HDR=(2) 2x10 W / CRIPPLE STUDS UNLESS NOTED DIFFERENT -HOUSE WRAP W / SEAMS OVERLAPPED AND SEALED -SIDING PER PLAN -7/16" ZIP-IT OR EQUAL SHEATHING -OPTIONAL 1/2" GYPSUM WALLS & CEILING -WALL INSULATION R-20 -FINISH MATERIALS BY OTHERS * DOUBLE TRIMMER STUDS REQUIRED FOR OPENINGS 48" OR GREATER IN EXTERIOR & / OR BEARING WALLS UNLESS NOTED DIFFERENT SOFFIT / FASCIA: (TYP) -2x3 NON-CORROSIVE DRIP EDGE -2x SUB FASCIA BLOCKING BETWEEN RAFTERS OR TRUSSES PER PLAN -1x6 FASCIA / RAKE BOARD WOOD SPECIES BY OTHERS -ALUMINUM FLASHING OVER FASCIA BOARD OR ANY EXPOSED WOOD NOT PRESSURE TREATED OR NATURALLY RESISTANT TO ROT, INSECTS OR DECAY TO BE STAINED OR SEALED -CONTINUOUS VENTED SOFFIT W / PROPER VENT (NOT REQUIRED IF CLOSED CELL SPRAY FOAM IS USED) -OVERHANG DISTANCES PER ELEVATIONS & / OR SECTIONS ROOF SYSTEM: (TYP) -MIN 30 YR ASPHALT SHINGLES OR METAL DETERMINED BY OTHERS & INSTALLED PER MANF. SPEC'S -CONTINUOUS RIDGE VENT (NOT REQUIRED IF CLOSED CELL SPRAY FOAM IS USED FOR CEILING INSULATION) -MIN 15 LB ROOFING FELT -ICE & WATER BARRIER MIN 48" FROM EAVE, RAKE & VALLEY. (IF SLOPE IS < 4/12, ICE & WATER BARRIER 100% ROOF COVERAGE OR USE LOW SLOPE ROOF MATERIAL) -MIN 5/8" OSB OR SIMILAR DECKING IF 24" O.C. RAFTER OR TRUSS SPACING -MIN 1/2" OSB OR SIMILAR DECKING IF 16" O.C. RAFTER OR TRUSS SPACING -RAFTERS, TRUSSES, PITCHES PER PLAN W / HURRICANE TIE H2.5 OR SIMILAR -PROPER VENT PER SOFFIT / FASCIA NOTE -CEILING INSULATION R-381/2" GYPSUM WALLS & CEILING (TYP) 3/4" ADVANTECK T&G SUBFLOOR OR EQUAL. GLUED & SCREWED DOWN. NO O.S.B. FINISHED FLOORING DETERMINED BY OTHERS (TYP) RAFTER TO WALL CONNECTION: HURRICANE TIE H2.5 OR SIMILAR (TYP) CONTINUOUS RIDGE VENT PERIMETER FLOOR INSULATION: R-30 (TYP) NON-CORROSIVE FLASHING WHERE ROOF MEETS WALL (TYP) RAFTERS & CEILING JOISTS PER PLAN RIDGE BEAM PER PLAN E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 1/4" = 1'-0" 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 3 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Building Section 25-03-017 06-16-25 SK RN ADDITION / RENOVATION A4 No . De s c r i p t i o n Da t e 1/4" = 1'-0"1 Section 1 T.O. New Roof 20' -6 1/8" T.O. Existing Basement Slab -6' -11" T.O. Existing Grade -1' -5" 6" O.H. 6" O.H. 3' - 0 " 7' - 0" EXISTING ROOF EXISTING BATH EXISTING CRAWL SPACE UNKNOWN CEILING HGT NEW WIC 42"+/- PREVIOUS EXTENT OF EXISTING ROOF / FASCIA / SOFFIT NEW ROOF / FASCIA / SOFFIT TO ALIGN & MATCH EXISTING. SISTER NEW ROOF RAFTERS TO EXISTING ROOF RAFTERS & OVERLAP 24" MIN 7' - 3 5 / 8 " 7' - 1 0 " DESIGN INTENT: EXTENSION OF EXISTING SHED ROOF & NEW ROOF PEAK TO MEET AT SAME ELEVATION SOLID BLOCK ABOVE EXISTING DOUBLE TOP PLATE / CEILING DESIGN INTENT:EXISTING BATH CEILING TO REMAIN SOLID BLOCKING BELOW WALL ABOVE (TYP) DECK FLOOR CONSTRUCTION PER PLAN NON-CORROSIVE FLASHING WHERE DECK MEETS WALL 6.79 NEW ROOF SLOPE REQUIRED TO FACILITATE DESIGN INTENT. BUILDER TO VERIFY NON-CORROSIVE FLASHING WHERE ROOF MEETS WALL (TYP) +/- * EXISTING INSULATION NOT SHOWN (TYP) T.O. New WIC Wall 2 16' -2" T.O. Existing Bath Floor -0' -1 3/4" T.O. Existing Bath Wall 1 7' -2 3/8" T.O. Existing WIC Second Floor 8' -4"NEW TO MATCH NON-CORROSIVE FLASHING WHERE ROOF MEETS WALL (TYP) KICK OUT FLASHING. ENSURE T.O. NEW ROOF IS BELOW B.O. EXISTING ROOF SOFFIT & DOES NOT EXTEND TO OR CONNECT CRICKET: ≈7/12 PITCH FROM EXISTING WALL TO FACE OF EXISTING FASCIA. NON-CORROSIVE FLASHING WHERE MEETS EXISTING WALL & SOFFIT CONTINUOUS RIDGE VENT BEAM PER PLAN 1" PROPER VENT AS REQUIRED. DO NOT COMPRESS INSULATION FLOOR JOISTS PER PLAN RAFTER TO BEAM CONNECTION: HURRICANE TIE H2.5 OR SIMILAR (TYP) PERIMETER FLOOR INSULATION: R-30 (TYP) RAFTERS & CEILING JOISTS PER PLAN REFER TO PREVIOUS SECTION FOR SIMILAR DETAILS 1/2" BEAD BOARD OR DETERMINED BY OWNER(S) FLOOR JOIST TO SOLID BLOCKING WALL CONNECTION: HURRICANE TIE H2.5 OR SIMILAR (TYP) SIMPSON STRONG-TIE LSTA30 STRAPS OVER SOLID BLOCKING @ DOWN EXISTING WALL STUDS MAX 32" O.C. SIMPSON STRONG-TIE SLOPEABLE HANGER: LRU212Z OR SIMILAR RIDGE BEAM PER PLAN E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 1/4" = 1'-0" 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 3 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Building Section 25-03-017 06-16-25 SK RN ADDITION / RENOVATION A5 No . De s c r i p t i o n Da t e 1/4" = 1'-0"1 Section 2 NOTE: THE PLOT PLAN SHOWN IS A CROPPED VIEW FROM THE ORIGINAL SURVEY THAT WAS PREPARED BY: THOMPSON FLEMING LAND SURVEYORS, P.C. 12 LAKE AVENUE SARATOGA SPRINGS, NY 12866 TEL: 518-587-5665 DATED: APRIL 25, 2018 TITLED: MAP OF LANDS OF ANDREW MASTERS SITUATE AT 127 GEORGE STREET CITY OF SARATOGA SPRINGS, SARATOGA COUNTY NY PROPOSED SECOND STORY ADDITION OVER EXISTING FIRST FLOOR EXTENTS 5' -0" SIDE SETBACK 6" SIDE O.H. 6" REAR O.H. PREVIOUSLY COMPLETED ADDITION SHOWN FOR REFERENCE 7'- 1"+/-17'- 10"+/- 6" ROOF OVERHANG (TYP) E-mail: amastersfurnrep@gmail.com Phone: 518-416-5379 C (18x24) Scale Project number Date Drawn by Engineer Paper Size Stamp EXPIRES 5/31/2027 CO M P A N Y C E R T I F I C A T I O N N O . 0 0 2 0 0 7 3 , E X P I R E S 1 2 / 3 / 2 5 WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E E D U C A T I O N LA W F O R A N Y P E R S O N , U N L E S S A C T I N G U N D E R TH E D I R E C T I O N O F A L I C E N S E D D E S I G N P R O F E S S I O N A L , TO A L T E R I N A N Y W A Y A N Y P L A N S , S P E C I F I C A T I O N S , PL O T S O R R E P O R T S T O W H I C H T H E S E A L O F A D E S I G N PR O F E S S I O N A L H A S B E E N A P P L I E D 1" = 20'-0" 6/ 1 6 / 2 0 2 5 1 2 : 5 2 : 4 4 P M MASTERS, ANDREW 127 GEORGE STREET SARATOGA SPRINGS, NY 12866 Plot Plan 25-03-017 06-16-25 SK RN ADDITION / RENOVATION P1 1" = 20'-0"1 PLOT PLAN No . De s c r i p t i o n Da t e