Loading...
HomeMy WebLinkAbout20250847 231 Lake Ave St. Clement's Church Exterior Modification Application St Clement's Church 231 Lake Ave Saratoga Springs, NY Prepared for: KC Entities Roofing & Siding 77 Ushers Rd Mechanicville, New York 12118 GAF Design Services Project # PD-00056284 TABLE OF CONTENTS Letters…………………………………………………………………………………………… Who is GAF Letter Contractor Certification Letter System Certification Letter Section I Specs………………………………………………………………………………….…….…… Cut Spec Assembly Rendering Section II Technical Data Sheets……………………………………………………………………….. EnergyGuard™ Polyiso Roof Insulation EverGuard® TPO 60 mil Membrane EverGuard® TPO Accessories EverGuard® TPO Adhesives, Primers and Sealants EverGuard® TPO Quick Spray Adhesive LV50 Drill-Tec™ #12 Fasteners Drill-Tec™ #14 Fasteners Drill-Tec™ Insulation Plates Drill-Tec™ Membrane Seam Plates Section III Safety Data Sheets……………………………………………………………………………. EnergyGuard™ Polyiso Roof Insulation EverGuard® TPO and Accessories EverGuard® TPO Adhesives, Primers and Sealants EverGuard® TPO Quick Spray Adhesive LV50 Drill-Tec™ Fasteners & Termination Bars Drill-Tec™ Plates Section IV Warranty Sample……………………………………………………………………………… EverGuard® Diamond Pledge™ NDL Roof Guarantee Section V is a GAF GoldElite™ Commercial Contractor Based on their consistent commitment to excellence and passion for quality, GAF Commercial is pleased to recognize this company as a GAF GoldElite™ Commercial Roofing Contractor. They are eligible to offer the following enhanced GAF Commercial Roofing Warranties and Guarantees for qualified projects: Diamond Pledge™ NDL Roof Guarantee System Pledge™ Roof Guarantee Integrated System Limited Warranty Alma Garnett SVP, Commercial Roofing Sales Pete Vollmar SVP, Sales Operations GAF ID: Contractors enrolled in GAF certification programs are not employees or agents of GAF, and GAF does not control or otherwise supervise these independent businesses. For more information, view the Contractor Terms of Use, available at gaf.com. 1127693 2025 KC Entities Roofing & Siding KC Entities Roofing &Siding 77 Ushers Rd Mechanicville,New York,12118 12/10/2024 GAF ID:1127693 Re:GAF GoldElite™Commercial Contractor Dear valued customer, On behalf of GAF Commercial,we are pleased to confirm that KC Entities Roofing &Siding is a GAF GoldElite™Commercial Contractor for 2025. KC Entities Roofing &Siding qualified to become a GAF GoldElite™Contractor based on their commitment to quality workmanship and customer service in commercial roofing.As a GAF GoldElite™Commercial Contractor,KC Entities Roofing &Siding is able to offer enhanced GAF warranties and guarantees including the Integrated System Limited Warranty,the System Pledge™Roof Guarantee for qualified projects,and our premier guarantee,the GAF Diamond Pledge™NDL Roof Guarantee. GAF prides itself on partnering with knowledgeable and reputable roofing businesses that share our commitment to delivering you the very best quality and service. Sincerely, Alma Garnett SVP,Commercial Roofing Sales Pete Vollmar SVP,Sales Operations Contractors enrolled in GAF certification programs are not employees or agents of GAF,and GAF does not control or otherwise supervise these independent businesses.For more information,view the Contractor Terms of Use ,available at gaf.com. Design Services Design Services | 1 Campus Drive, Parsippany, NJ 07054 | Toll Free 877.423.7663 | gaf.com May 9, 2025 KC Entities Roofing & Siding 77 Ushers Rd Mechanicville, New York 12118 Subject: System Certification Project: St Clement's Church 231 Lake Ave Saratoga Springs, NY Project Identifier: PD-00056284 Quote Number: QUO-16169-6FEKE1 – 1 To Whom It May Concern: Please allow this letter to confirm that the contractor listed above is a GAF GoldElite Roofing Contractor for Single-ply Roofing Systems and is eligible to obtain the guarantee listed below. The GAF roofing specification as listed below is eligible to obtain a 20 year EverGuard® Diamond Pledge™ NDL Roof Guarantee provided all current GAF application requirements are followed and guarantee procedures are met. TMARI60 - 15/32" Plywood Deck /BUR • A moisture survey is strongly recommended, and in some circumstances, required to identify all wet areas. Take test cuts to verify existing roof construction and condition. • Remove any loose gravel, dirt and debris from the existing surface. • Inspect existing insulation and remove and replace any materials that are damaged or contain moisture. Remove all existing flashing materials. • Existing materials and any unforeseen issues are excluded from the GAF Guarantee. The above listed roofing system is based on GAF guarantee requirements and is not intended to modify, negate, or alter any requirements specified by the design professional , local building codes, or others. If you have any further questions, please contact us at 877-423-7663 (Option 4, Option 3). Thank you for choosing GAF. Sincerely, Traci Hicks Traci Hicks Regional Lead, Design Services EnergyGuard™ Polyiso Insulation: Mechanically fasten the 3.0" EnergyGuard™ Polyiso Insulation to the structural decking using Drill-Tec™ #12 Fastener and Drill-Tec™ 3" Standard Steel Plate, as follows: • Field: 5 fasteners per 4' x 8' board • Perimeter: 5 fasteners per 4' x 8' board • Corner: 5 fasteners per 4' x 8' board EverGuard® TPO: Install EverGuard® TPO 60 mil using Drill-Tec™ #14 Fastener fastened with Drill-Tec™ 2 3/8 in. Barbed XHD Plate, fastened 12” o.c. within the 6” wide laps, spaced 114" o.c., and sealed with a 1.5” heat weld. Half sheets are required at the perimeter, please refer to the table in the current specification manu al or applicable version of ASCE for proper half sheet calculations and requirements. *For decks less than 3/4", fastener spacing is based on a minimum 400 lbf fastener pull out value. Building must be enclosed and attachment rates listed above are not applicable for regions prone to “high-winds”, such as Florida’s HVHZ counties, or Special Wind Regions as designated in ASCE's Basic Wind Speed Maps. For buildings exceeding these specifics, contact GAF Design Services. QUO-16169-6FEKE1 – 1 5/9/2025 Page 1 of 1 designservices@gaf.com Design Services 877-423-7663 (Option 4, Option 3) St Clement's Church 231 Lake Ave Saratoga Springs, NY SPECIFICATION: TMARI60 COMPONENT TYPE REQUIRED ATTACHMENT RATE OF APPLICATION DECK Plywood 15/32" Per Code N/A EXISTING SUBSTRATE Existing BUR Prepare existing substrate as defined below INSULATION 1 EnergyGuard™ Polyiso Insulation, 20 psi ASTM C1289 Type II, Class 1, Grade 2 Size: 3.0", 4' x 8' LTTR: 17.4 1 layer Fastened with: Drill-Tec™ #12 Fastener Drill-Tec™ 3" Standard Steel Plate Preliminary attachment: Field: 5 Fasteners per 4' x 8' board Perimeter: 5 Fasteners per 4' x 8' board Corner: 5 Fasteners per 4' x 8' board SINGLE PLY MEMBRANE EverGuard® TPO 60 mil White ASTM D6878 Size: 10ft SRI: 94 1 ply Fastened with: Drill-Tec™ #14 Fastener Drill-Tec™ 2 3/8 in. Barbed XHD Plate 10' sheets fastened 12” o.c. in the 6” wide laps and sealed with a 1.5” heat weld. Half sheets are required at the perimeter, please refer to the table in the current specification manual or applicable version of ASCE for proper half sheet calculations and requirements. For decks less than 3/4", fastener spacing is based on a minimum 400 lbf fastener pull out value. Building must be enclosed and attachment rates listed above are not applicable for regions prone to “high-winds”, such as Florida’s HVHZ counties, or Special Wind Regions as designated in ASCE's Basic Wind Speed Maps. For buildings exceeding these specifics, contact GAF Design Services. FLASHING MEMBRANE EverGuard® TPO 60 mil White ASTM D6878 SRI: 94 1 ply EverGuard® TPO Quick Spray Adhesive LV50 Applied at a total rate of 10 squares (1,000 sq. ft.) per canister equally to both the substrate and the underside of the membrane. Membrane shall be run up and over the wall. GUARANTEE EverGuard® Diamond Pledge™ NDL Roof Guarantee 20 year Guarantee fee applicable Requirements above are subject to change. Always review the appropriate Application & Specification Manual to confirm that the requirements provided above are current, and to obtain additional information that is important for a successful installation. This Cut Spec specification shall not waive, supersede or alter the requirements and recommendations found in the most current Application & Specification Manual(s), printed technical bulletins or specific correspondence drafted for this project by Field Services, Design Services, or Technical Services Manager. Application & Specification Manuals and specimen copies of guarantee/warranty documents are available at www.gaf.com. Note: Your Field Services or Technical Services Managers are the only employees who can approve any deviation from GAF's published specification manual(s). Each roof has unique requirements. This specification is a representation of products and their installation. To properly assess specific roofing needs, code compliance, system configurations, and warranty eligibility, contact Design Services. The above listed roofing system is based on GAF guarantee requirements and is not intended to modify, negate or alter any requirements specified by the design professional or others. Fastener pullout testing should be performed to ensure acceptable attachment into substrate. Adhesion testing is required prior to guarantee registration to ensure foam adhesive will bond to a given substrate. Any wet or damaged existing decking must be removed and replaced prior to re-roofing. This system shall be installed by a GAF GoldElite™ Commercial Contractor. All GAF and EverGuard® accessories shall be used where applicable. Prepare substrate in accordance with GAF requirements, including but not limited to, removal and replacement of wet or damaged materials/insulation, and removal of existing flashing materials. Sweep and remove all loose gravel and clean debris from roof surface. Re-secure any existing insulation as required. Any existing single ply membrane must be cut into 10' x 10' sections. Moisture survey is recommended and in some circumstances required. If new roofing is to be adhered to any coated surface, it must be power washed to remove loose and delaminating materials. Every effort must be made to remove existing coatings as part of the cleaning process and silicone based coatings MUST be removed completely. Adhesion failures due to existing coatings are not covered by the GAF Guarantee, so it is important to test adhesion prior to proceeding with installation of new materials. Existing materials are excluded from the GAF Guarantee. 0HPEUDQH 0HPEUDQH$WWDFKPHQW &RYHU%RDUG &RYHU%RDUG$WWDFKPHQW 1HZ,QVXODWLRQ 1HZ,QVXODWLRQ$WWDFKPHQW ([LVWLQJ6XEVWUDWH 'HFN7\SH &RQVWUXFWLRQ7\SH *$)'HVLJQ6HUYLFHV ŏ 2SW2SWŏ GHVLJQVHUYLFHV#JDIFRP 'UDZLQJQRWWRVFDOH  7KHLPDJHVVKRZQDUHIRULOOXVWUDWLRQSXUSRVHVRQO\DQGPD\QRWEHDQH[DFWUHSUHVHQWDWLRQRIWKHSURGXFWV 63(&,),&$7,21  , 'UDZLQJQRWWRVFDOH 7KHLPDJHVVKRZQDUHIRULOOXVWUDWLRQSXUSRVHVRQO\DQGPD\QRWEHDQH[DFWUHSUHVHQWDWLRQRIWKHSURGXFWV'UDZLQJ QRW WR VFDOH 7KH LPDJHV VKRZQ DUH IRU LOOXVWUDWLRQ SXUSRVHV RQO\ DQG PD\ QRW EH DQ H[DFW UHSUHVHQWDWLRQ RI WKH SURGXFWV EverGuard® TPO 60 mil Membrane Drill-Tec™ #14 Fasteners & 2-3/8” Barbed XHD Plates N/A EnergyGuard™ Polyiso Insulation N/A Plywood Deck - 15/32" Recover Drill-Tec™ #12 Fasteners & 3” Standard Steel Plates St Clement's Church BUR EverGuard® TPO 60 mil Membrane, ASTM D6878 Fastened with Drill-Tec™ Fasteners & Plates New Insulation: EnergyGuard™ Polyiso Insulation, ASTM C1289 Drill-Tec™ Fasteners & Plates Existing Substrate: BUR over Existing Insulation Deck Type: Plywood Deck - 15/32" T60RMA SP E C I M E N GAF 1 CAMPUS DRIVE PARSIPPANY, NJ 07054 Visit gaf.com EverGuard® Diamond Pledge™ NDL Roof Guarantee ©2024 GAF • COMTS700-1224 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ OWNER OF BUILDING _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ NAME OF BUILDING _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ADDRESS OF BUILDING _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ AREA OF ROOF (SQUARES) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ APPLIED BY _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ GUARANTEE NUMBER _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ PERIOD OF COVERAGE _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ DATE OF COMPLETION _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ GUARANTEE EXPIRATION DATE _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ROOF SPECIFICATION By: _________________________________________________________ Authorized Signature THE GUARANTEE/SOLE AND EXCLUSIVE REMEDY GAF Warranty Company LLC ("GAF") guarantees to you, the owner of the building described above, that GAF will provide “Edge To Edge” protection by repairing leaks through the GAF roofing membrane, liquid-applied membrane or coating, base flashing, high-wall waterproofing flashing, insulation, expansion joint covers, preflashed accessories, and metal flashings used by the contractor of record that were designed and installed in accordance with an appropriate ES-1 certified edge detail (the “GAF Roofing Materials”) resulting from a manufacturing defect, ordinary wear and tear, or workmanship in applying the GAF Roofing Materials. There is no dollar limit on covered repairs. Leaks caused by any non-GAF materials, such as the roof deck or non-GAF insulation, are not covered. GUARANTEE PERIOD This guarantee ends on the expiration date listed above. OWNER RESPONSIBILITIES Notification of Leaks In the event of a leak through the GAF Roofing Materials, you MUST make sure that GAF is notified directly about the leak, in writing, within 30 days either online at leakreporting.gaf.com, by email at guaranteeleak@gaf.com, or by postal mail to GAF Warranty Claims Department, 1 Campus Drive, Parsippany, NJ 07054, or GAF will have no responsibility for making repairs. NOTE: The roofing contractor is NOT an agent of GAF; notice to the roofing contractor is NOT notice to GAF. By notifying GAF, you authorize GAF to investigate the cause of the leak. If the investigation reveals that the leak is not covered by this guarantee, you agree to pay an investigation cost of $500. This guarantee will be cancelled if you fail to pay this cost within 30 days of receipt of an invoice for it. Preventative Maintenance and Repairs A. You must perform regular inspections and maintenance and keep records of this work. B. To keep this guarantee in effect, you must repair any conditions in the building structure or roofing system that are not covered by this guarantee but that GAF concludes may be threatening the integrity of the GAF Roofing Materials. Any such repairs must be performed by a GAF-certified roofing contractor. Failure to make timely repairs may jeopardize guarantee coverage. C. You may make temporary repairs to minimize damage to the building or its contents in an emergency, at your sole expense. These repairs will not result in cancellation of the guarantee as long as they are reasonable and customary and do not result in permanent damage to the GAF Roofing Materials. D. Any equipment or material that impedes any inspection or repair must be removed at your expense so that GAF can perform inspections or repairs. EXCLUSIONS FROM COVERAGE (e.g., items that are not “ordinary wear and tear” or are beyond the control of GAF) This guarantee does NOT cover conditions other than leaks. This guarantee also does NOT cover leaks caused by any of the following: 1. Inadequate roof maintenance, that is, the failure to follow the Scheduled Maintenance Checklists provided with this guarantee (extra copies available by calling Guarantee Services at 1-877-GAF-ROOF) or the failure to repair owner responsibility items. 2. Unusual weather conditions or natural disasters including, but not limited to, winds in excess of 55 miles per hour, hail, floods, hurricanes, lightning, tornados, and earthquakes, unless specifically covered by an addendum to this guarantee. 3. Impact of foreign objects or physical damage caused by any intentional or negligent acts, accidents, misuse, abuse, or the like. 4. Damage to the roof constructed of the GAF Roofing Materials due to: (a) movement, cracking, or other failure of the roof deck or building; (b) improper installation or failure of any non-GAF insulation or materials; (c) condensation or infiltration of moisture through or around the walls, copings, building structure, or surrounding materials except where high-wall GAF waterproofing flashings are installed; (d) chemical attack on the membrane, including, but not limited to, exposure to grease or oil; (e) the failure of wood nailers to remain attached to the structure; (f) moisture migration from the building interior or any building component other than the GAF Roofing Materials; (g) use of materials that are incompatible with the GAF Roofing Materials; or (h) architectural, engineering, or design defects or flaws. 5. Traffic of any nature on the roof unless using GAF walkways applied in accordance with GAF published application instructions. 6. Blisters in the GAF Roofing Materials that have not resulted in leaks. 7. Changes in the use of the building or any repairs, installation of any overburden, modifications, or additions to the GAF Roofing Materials after the roof is completed, unless prior written approval is obtained from GAF. 8. Exposure to sustained high-temperature conditions; however, for systems utilizing EverGuard Extreme® TPO membrane, exposure in excess of 195°F. No representative, employee, or agent of GAF, or any other person, has the authority to assume any additional or other liability or responsibility for GAF, unless it is in writing and signed by an authorized GAF Field Services Manager or Director. GAF does not practice engineering or architecture. Neither the issuance of this guarantee, nor any review of the roof constructed of the GAF Roofing Materials (or the plans for the roof), by GAF shall constitute any warranty of such plans, specifications or construction, or the suitability or code compliance of the GAF Roofing Materials for any particular structure. NOTE: Any inspections made by GAF are limited to a surface inspection only, are for the sole benefit of GAF, and do not constitute a waiver or extension of any of the terms and conditions of this guarantee. This guarantee MAY BE SUSPENDED OR CANCELLED IF THE ROOF IS DAMAGED BY any cause listed above as AN EXCLUSION FROM COVERAGE that may affect the integrity or watertightness of the roof. TRANSFERABILITY You may transfer or assign this guarantee to a subsequent owner of this building for the remaining term only if: 1) the request is in writing to GAF at the address listed below within 60 days after ownership transfer; 2) you make any repairs to the GAF Roofing Materials or other roofing or building components that are identified by GAF after an inspection as necessary to preserve the integrity of the GAF Roofing Materials; and 3) you pay an assignment fee of $500. This guarantee is NOT otherwise transferable or assignable by contract or operation of law, either directly or indirectly. LIMITATION OF DAMAGES; MEDIATION; JURISDICTION; CHOICE OF LAW THIS GUARANTEE IS EXPRESSLY IN LIEU OF ANY OTHER GUARANTEES OR WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, and of any other obligations or liability of GAF, whether any claim against it is based upon negligence, breach of warranty, or any other theory. In NO event shall GAF be liable for any CONSEQUENTIAL OR INCIDENTAL DAMAGES of any kind, including, but not limited to, interior or exterior damages and/or mold growth. The parties agree that, as a condition precedent to litigation, any controversy or claim relating to this guarantee shall be first submitted to mediation before a mutually acceptable mediator unless GAF, at its sole option, elects to waive said requirement. In the event that mediation is unsuccessful, or is waived by GAF, the parties agree that neither one will commence or prosecute any lawsuit or proceedings other than before the appropriate state or federal court in the State of New Jersey. This guarantee shall be governed by the laws of the State of New Jersey, without regard to principles of conflicts of laws. Each party irrevocably consents to the jurisdiction and venue of the above identified courts. NOTE: GAF shall have no obligation under this guarantee unless and until all bills for installation and supplies have been paid in full to the roofing contractor and materials suppliers, and the guarantee charge has been paid to GAF. Flat Polyiso with GRF Facers We protect what matters most™ Description: EnergyGuard™ Polyiso Insulation made of glass fiber reinforced cellulosic facers (GRF) bonded to a core of polyisocyanurate foam. Features and Benefits: n Versatile — approved component in single ply, BUR and modified bitumen systems, with a variety of attachment methods: mechanically attached, fully adhered, loose laid and ballasted n Approved for direct application to steel decks n High insulation value — polyiso insulation has the highest R-value per inch compared to any other type of non-polyiso insulation of equivalent thickness n Because of its light weight, this material is easy to handle on the jobsite and installs quickly. Easy cutting in the field provides the installer with simplified fabricating on the roof deck n Excellent dimensional stability, high moisture resistance and low water permeability Panel Characteristics: n Available in a variety of thicknesses from 1.0" (25.4 mm) to 4.6" (116 mm) to best suit your specifications n Available in 4' x 4' (1.22 m x 1.22 m) and 4' x 8' (1.22 m x 2.44 m) boards n Flute Fill and other special sizes are available upon request n Other EnergyGuard™ products available – tapered, CGF facer and non-halogenated. See individual data sheets for more information Codes & Compliance: n Meets the requirements of ASTM C1289 Type II, Class 1, Grade 2 (20 psi) and also available in Grade 3 (25 psi) n FM Approved - refer to RoofNav.com for approved assemblies n Classified by UL in accordance with ANSI/UL 1256, 790 and 263. Refer to UL Product iQ for specific assemblies n UL Evaluation Report UL ER1306-03 n Miami-Dade County Product Control Approved n State of Florida Approved n Meets the requirements of CAN/ULC 704.1, Type 2, Class 3 or Type 3, Class 3† n UL (Canada) Evaluation Report ULC ER 1306† n For additional information, contact GAF at 1-800-766-3411 or designservices@gaf.com † GAF manufacturing locations in UT and PA. EnergyGuard™ Polyiso Insulation Thermal Values: Size*R-Value**Max Flute Span (in) 1.0" (25.4 mm)5.7 2 5/8" (66.7 mm) 1.2" (30.5 mm) 6.8 2 5/8" (66.7 mm) 1.5" (38.1 mm)8.6 4 3/8" (111 mm) 1.75" (44.5 mm) 10.0 4 3/8" (111 mm) 2.0" (51 mm)11.4 4 3/8" (111 mm) 2.2" (59 mm)12.6 4 3/8" (111 mm) 2.3" (58 mm) 13.2 4 3/8" (111 mm) 2.5" (64 mm)14.4 4 3/8" (111 mm) 2.6" (66 mm)15.0 4 3/8" (111 mm) 2.8" (71 mm)16.2 4 3/8" (111 mm) 3.0" (76 mm)17.4 4 3/8" (111 mm) 3.2" (81 mm)18.6 4 3/8" (111 mm) 3.5" (89 mm)20.5 4 3/8" (111 mm) 3.7" (94 mm) 21.7 4 3/8" (111 mm) 4.0" (102 mm)23.6 4 3/8" (111 mm) 4.3" (109 mm) 25.4 4 3/8" (111 mm) 4.5" (114 mm)26.6 4 3/8" (111 mm) 4.6" (117 mm)27.1 4 3/8" (111 mm) * Other thicknesses available upon request. ** Long Term Thermal Resistance Values provide a 15-year time weighted average in accordance with CAN/ULC 770. For optimal roof performance and to prevent thermal bridging GAF recommends installing two layers of Polyiso with staggered joints. Visit gaf.com We protect what matters most™ Warnings and Limitations: n EnergyGuard™ Polyiso Insulation is a non-structural, non load-bearing material. It is not designed for direct traffic usage unless adequately protected. n EnergyGuard™ Polyiso Insulation should be stored protected from the elements. Bundle wrap is not for use as waterproofing for boards. No more insulation should be installed than can be completely covered with roofing on the same day. n As unprotected polyisocyanurate will burn, fire safety precautions should be observed wherever insulation products are used. n Direct mopping or torching of modified bitumen roofing or direct mopping of built-up roofing (BUR) to EnergyGuard™ Polyiso Insulation is not approved. A properly installed cover board or base sheet must be used. n Refer to PIMA Technical Bulletin No. 109 Storage and Handling Recommendations for Polyiso Roof Insulation at www.polyiso.org n Refer to the application specifications in the current membrane manufacturer's application and specifications manual for proper installation procedures. ©2 0 2 3 G A F • C O M G T 3 1 8 - P D F - 0 8 2 4 Visit gaf.com Typical Physical Property Data: Property Test Method Values Compressive Strength ASTM D1621 Grade 2 – 20 psi min (138 kPa) Grade 3 – 25 psi min (172 kPa) Dimensional Stability Change (length + width) 2 ASTM D2126 < 2% linear change Flexural Strength ASTM C203 40 psi min (275 kPa) Tensile Strength ASTM C209 500 psf min (24 kPa) Water Absorption (percent by volume)ASTM C209 1.5% max Water Vapor Permeance ASTM E96 Procedure A < 1.5 perm max (85.8ng/Pa•s•m2) Service Temperature -100° to 250 °F (-73.3° to 121.1 °C) Flame Spread Index 3 ASTM E84 < 75 1 Smoke Developed Index ASTM E84 < 200 1 Sustainability: n Manufactured with EPA-compliant blowing agents containing no CFCs or HCFCs; has zero ozone depletion potential (ODP) and negligible global warming potential (GWP) n GREENGUARD Gold n Green Circle Certified® for recycled content n Potential LEED® Credits for Polyiso Use n Environmental Product Declaration (EPD) MEMBER 1 Foam Core 2 Stated dimensional stability tolerance: Board thickness shall not diminish by more than 4% max. 3 These numerical ratings are not intended to reflect hazards presented by these or any other material under actual fire conditions. For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Durable. Efficient. Proven. GAF knows thermoplastic polyolefin (TPO). Our EverGuard® TPO membrane construction has remained unchanged for decades. It’s just one of the reasons we’ve sold more than 6 billion square feet. EverGuard® TPO offers flexibility, durability, UV reflectivity, and heat- sealable properties. It’s inherently fungal resistant* and flexible without using plasticizers. Available in nominal and minimum thicknesses. Competitive pricing and a 20-plus-year track record for performance make TPO the most popular option in the commercial roofing industry and specialized training from GAF Roofing It Right videos and CARE classes add to GAF's unmatched technical support. Durable. Efficient. Proven. EverGuard® TPO is suitable for all types of single-ply systems: n Mechanically Attached — for a quick and cost-effective system that can be installed practically year-round. n Induction Welded — can be applied without using adhesives and installed practically year round. Qualifies for the same guarantee length as an adhered system.† n Adhered — can be installed with EverGuard® TPO Quick Spray, EverGuard® TPO Quick Spray LV50, EverGuard® TPO Low VOC Bonding Adhesive, EverGuard® TPO 3 Square Low VOC Bonding Adhesive, EverGuard® TPO SBA 1121 Bonding Adhesive, or EverGuard® WB 181 Bonding Adhesive for the smoothest appearance. Features: EverGuard® TPO offers the following: n Endures 2 to 2.5 times the industry standard, depending on thickness (ASTM D6878 weather resistance test). n Offers guarantees for eligible systems up to 20 years for 45 mil, 25 years for 60 mil, and 30 years for 80 mil.† n Available in 12' rolls to cover more area with fewer rolls and seams n Allows for heat-welded seams that provide greater seam strength to taped and other seams n Creates a highly reflective and emissive white roof that can help reduce cooling costs‡ and urban heat island effect. (white, energy tan and energy gray only) TPO Field Study: As a relatively new roof technology, TPO performance was proven mostly in lab studies. So when real-world TPO systems started approaching 20-year marks, GAF acquired and analyzed EverGuard® TPO samples across the United States. We found 8- to 16-year-old TPO roofs to be performing well and in most instances, meeting the current ASTM D 6878-19 requirements for new membranes. Download the study from GAF.com. Accessories: EverGuard® TPO prefabricated accessories deliver consistent quality and eliminate the worry and problems often associated with field fabrication. They can also boost productivity while reducing labor. n Coated Speedtite™ and Hercules® Drain — TPO-coated flange for direct hot-air welding of TPO roof membranes. n Corner Curb Wrap — Four standard sizes to flash 24”, 36”, 48”, and 60” curbs. n Fluted Corner — For use in flashing outside corners of base and curb flashing. n Inside Corner — Manufactured to accommodate inside corners of base or curb flashing. n Preformed Split Pipe Boot — Three standard sizes accommodate most pipes and conduits. n Preformed Vent Boot — Accommodates most common pipes and conduits from 1" (25.4 mm) to 6" (152 mm). n Scupper — Heat-welds to the scupper for a strong, secure installation. n Split Pourable Sealant Pocket — Cuts to size and offers a low profile to help seal varying penetrations with less sealant. n Square Tube Wrap — Tube wraps are split with overlaps to wrap around square or rectangular tubing. n T-Joint Cover Patches — Conforming seal for use over T-joints in 60- and 80-mil membrane applications. n TPO Cover Tape — Self-adhered TPO ideal for stripping-in TPO and edge metal. n Universal Corner — Accommodates both inside and outside corners of base and curb flashings. n Vent — For use in venting low-slope mechanically attached roofs. n Walkway Roll — Heat-welds directly to TPO membrane or installs with seam tape. Available in gray and yellow. * Meets ASTM G21. GAF warranties and guarantees do not provide coverage against fungi or other biological growth. Refer to gaf.com for more information on warranty and guarantee coverage and restrictions. † Additional requirements apply. Contact GAF for more information. Refer to sample guarantees, available at gaf.com, for complete coverage and restrictions. ‡ Energy cost savings are not guaranteed and the amount of savings may vary based on climate zone, utility rates, radiative properties of roofing products, insulation levels, HVAC equipment, efficiency and other factors. 45, 60, 80 mil We protect what mat ters most™ Physical Properties (ASTM D6878) Type ASTM Test Method ASTM D 6878 Minimum EverGuard® TPO Test Values (approx.)* 45 mil 60 mil3 80 mil TPO Nominal Thickness ASTM D751 0.039”0.045" (1.14 mm)0.060" (1.52 mm)0.080" (2.03 mm) Thickness Over Scrim ASTM 7635 0.015” 15.8 mil (nominal)24.1 mil (nominal)31.4 mil (nominal) Breaking Strength ASTM D751 Grab Method MD 220 lbf 375 lbf x 330 lbf (559 x 492 kg/m) 400 lbf x 360 lbf (596 x 536 kg/m) 440 lbf x 390 lbf (656 x 581 kg/m) Elongation at Break ASTM D751 15%30%30%30% Tear Strength ASTM D751 (8” x 8” sample)55 lbf 90 lbf x 120 lbf (134 x 179 kg/m) 70 lbf x 130 lbf (104 x 194 kg/m) 100 lbf x 180 lbf (149 x 268 kg/m) Brittleness Point ASTM D2137 -40 °F -40 °F -40 °F -40 °F Ozone Resistance ASTM D1149 No cracks @ 7x magnification No visible deterioration @ 7x magnification No visible deterioration @ 7x magnification No visible deterioration @ 7x magnification Properties after Heat Aging ASTM D573 ≤1.5% weight change after 8 weeks @ 275° F, No cracks @ 7x magnification Pass Pass Pass Properties after Heat Aging, UAWS Total radiation @ 8400 MJ/m2 UV, no cracking Pass Pass Pass Linear Dimensional Change ASTM D1204 ±1%0.2%0.4%0.4% Water Absorption ASTM D471 ±3%0.7%0.7%0.7% Factory Seam Strength ASTM D751 66 lbf 115 lbf (membrane failure) (171 kg/m) 145 lbf (membrane failure) (216 kg/m) 155 lbf (membrane failure) (231 kg/m) Weather Resistance ASTM G155 10,080 kJ(m2•nm) at 340 nm, No cracks @ 7x magnification >20,000 kJ(m2•nm) at 340 nm >25,000 kJ(m2•nm) at 340 nm >25,000 kJ(m2•nm) at 340 nm Air Permeance ASTM E2178 <0.02 L/(s • m²)<0.02 L/(s • m²)<0.02 L/(s • m²) Note 1: Certain data is provided in MD (machine direction) x CMD (cross machine direction) format. Note 2: Values stated are approximate and subject to normal manufacturing variation. These values are not guaranteed and are provided solely as a guide. Note 3: Also available in minimum 60 mil thickness. Additional Physical Properties Puncture Resistance FTM 101 C Method 2031 Not established >350 lb. (159 kg)>380 lb. (172 kg)>380 lb. (172 kg) Permeance ASTM E96 Not established <0.08 Perms <0.08 Perms <0.08 Perms Guarantee Up to 20 years Up to 25 years Up to 30 years Sustainability Ratings/Certifications Cool Roof Rating Council (CRRC) Color Rated Product ID# Initial Aged Solar Reflectance (ASTM C 1549) Thermal Emittance (ASTM C 1371) Solar Reflectance Index (ASTM E 1980) Solar Reflectance (ASTM C 1549) Thermal Emittance (ASTM C 1371) Solar Reflectance Index (ASTM E 1980) White 0676-0001 0.76 0.90 94 0.68 0.83 81 Energy Gray 0676-0045 0.72 0.87 88 0.67 0.90 82 Energy Tan 0676-0039 0.72 0.89 89 0.66 0.89 80 LEED Information Manufacturing Location Mount Vernon, IN, New Columbia, PA, Cedar City, UT, Gainesville, TX For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com 45, 60, 80 mil Applicable Standards/Approvals Miami Dade County Product Control Approved UL Evaluation Report UL ER1306-01 ICC-ES Evaluation Report ESR-4676 (Cedar City, UT only) FM Approved (Refer to FM RoofNav.com for actual assemblies) Meets or exceeds the requirements of ASTM D6878.State of Florida Approved Classified by UL in accordance with ANSI/UL 790. (Refer to UL Product iQ for actual assemblies). Meets or exceeds the requirements of the Texas Department of Insurance. CRRC Rated — Can be used to comply with 2022 Title 24, Part 6, Cool Roof Requirements of the California Code of Regulations (White, Energy Tan, and Energy Gray only) Product Data Roll Size EverGuard® TPO 45 EverGuard® TPO 60 EverGuard® TPO 80 12’ Roll Size 12' x 100' (3.66 x 30.5 m) 1,200 sq. ft. (111.5 sq.m) 12' x 100' (3.66 x 30.5 m) 1,200 sq. ft. (111.5 sq.m) 12' x 100' (3.66 x 30.5 m) 1,200 sq. ft. (111.5 sq.m) 12’ Roll Weight (Average)307 lb. (139 kg)386 lb. (175 kg)504 lb. (228 kg) 10’ Roll Size 10' x 100' (3.05 x 30.5 m) 1,000 sq. ft. (92.9 sq.m) 10' x 100' (3.05 x 30.5 m) 1,000 sq. ft. (92.9 sq.m) 10' x 100' (3.05 x 30.5 m) 1,000 sq. ft. (92.9 sq.m) 10’ Roll Weight (Average)256 lb. (116 kg)322 lb. (146 kg)420 lb. (191 kg) 8’ Roll Size 8’ x 100’ (2.43 x 30.5 m) 800 sq. ft. (74.3 sq.m) 8’ x 100’ (2.43 x 30.5 m) 800 sq. ft. (74.3 sq.m) 8’ x 100’ (2.43 x 30.5 m) (800 sq. ft. (74.3 sq.m) 8’ Roll Weight (Average)204 lb. (93 kg)257 lb. (117 kg)336 lb. (152 kg) 6’ Roll Size 6’ x 100’ (1.83 x 30.5 m) 600 sq. ft. (55.7 sq.m) 6’ x 100’ (1.83 x 30.5 m) 600 sq. ft. (55.7 sq.m) 6’ x 100’ (1.83 x 30.5 m) 600 sq. ft. (55.7 sq.m) 6’ Roll Weight (Average)153 lb. (70 kg)194 lb. (88 kg)252 lb. (114 kg) 5’ Roll Size 5’ x 100’ (1.52 x 30.5 m) 500 sq. ft. (46.5 sq.m) 5’ x 100’ (1.52 x 30.5 m) 500 sq. ft. (46.5 sq.m) 5’ x 100’ (1.52 x 30.5 m) 500 sq. ft. (46.5 sq.m) 5’ Roll Weight (Average)128 lb. (58 kg)162 lb. (74 kg)210 lb. (95 kg) Product Data Cont. Colors White, Gray, Energy Gray, Slate Gray, Tan, Energy Tan, Desert Tan, Dark Bronze, Dark Brown, Goldenrod, Sky Blue, Regal Blue, Electric Blue, Hartford Green, Patina Green, Regal Red, Terra Cotta. Storage Store on pallets in a clean, dry area at temperatures below 100°F (38ºC). Safety Warning Membrane rolls are heavy. Employ at least two people to position and install. 45, 60, 80 mil ©2 0 2 4 G A F • C O M E G 8 7 6 - P D F - 0 5 2 4 We protect what mat ters most™ For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com We protect what matters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 8 5 2 - P D F - 0 1 2 3 TPO Accessories Description: Increase efficiency when creating edges, flashing, and other sheet metal details with EverGuard® and EverGuard® Extreme TPO-Coated Metal Sheets. This accessory cuts and forms like standard sheet metal. GAF manufactures these and other accessories from its proven, durable EverGuard® TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Use for metal gravel stop and drip edges, metal base and curb flashing, sealant pans, and scupper sleeves. Field and flashing TPO membrane heat welds directly to coated metal. For additional information, contact GAF Technical Support at 1-800-766-3411 or technicalquestions@gaf.com Specifications Size 4' (1.21 m) x 10' (3.05 m) Membrane thickness 0.025" (0.64 mm) Weight per sheet 40 lb. (18.14 kg) Shipping Specifications Sheets per pallet 5 10 30 EverGuard® TPO 760A 7600920 7603920 EverGuard® Extreme TPO –7600776 7603776 Product Information: Metal sheets measure 4' (1.21 m) x 10' (3.05 m) and are constructed from 24 ga. steel with 25-mil EverGuard® or EverGuard Extreme® TPO membrane. Metal sheets are also available in aluminum, stainless, and 20 ga. galvanized with a 2-4 week lead time. We protect what matters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 1 9 7 - P D F - 1 0 2 3 Description: Increase efficiency when stripping-in coated metal flanges and areas that require a reinforced membrane for flashing with factory-built EverGuard® and EverGuard Extreme® TPO Utility Flashing Membrane. This single-ply roofing system accessory provides roofing contractors with an effective, easy-to-install component. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard Extreme® TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: EverGuard® and EverGuard Extreme® TPO 45-Mil and 60-Mil Utility Flashing Membrane can be installed on EverGuard® and EverGuard Extreme® TPO (any thickness) mechanically attached or fully adhered roofing systems. See published application and specifications manual for detailed instructions. For additional information, contact GAF Design Services Support at 1-877-423-7663 or designservices@gaf.com Specifications Roll size 8" x 100' (203 mm x 30.5 m) rolls Material Reinforced TPO membrane Shipping Specifications Weight per roll 18 lb. / 8.2 kg (45-mil), 22 lb. / 10 kg (60-mil) Product SKU EverGuard® TPO EverGuard Extreme® TPO 45-mil 7608920 7608776 60-mil 7614920 — Product Information: EverGuard® and EverGuard Extreme® 45-Mil and 60-Mil Utility Flashing Membrane is available in white. Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com ©2 0 2 4 G A F • C O M E G 1 9 6 - P D F - 0 4 2 4 TPO Accessories Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Description: Increase efficiency with the EverGuard® and EverGuard Extreme® TPO UN-55 Detailing Membrane. This single-ply roofing system accessory provides roofing contractors with an effective, easy-to-install component, especially when preformed boots, corners, and other preformed details cannot be used. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard Extreme® TPO single-ply unreinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: EverGuard® and EverGuard Extreme® TPO UN-55 Detailing Membrane may be installed on EverGuard® and EverGuard Extreme® TPO (any thickness) mechanically attached or fully adhered roofing systems. See published application and specifications manual for detailed instructions. Product Information: EverGuard® and EverGuard Extreme® TPO UN-55 Detailing Membrane is available in white. Talk to your representative about additional available colors. The unreinforced membrane makes installation easier at difficult flashing details. Specifications Roll size 24" x 50' rolls (610 mm x 15.24 m) Material 55-mil unreinforced TPO membrane Shipping Specifications Weight per roll 28 lb. / 12.7 kg Product SKUs EverGuard® TPO EverGuard Extreme® TPO White 7631920 7624776 TP O TP O Description EverGuard® TPO single-ply roofing system coated metal drain accessory provides roofing contractors an easy-to-install, factory-built detail. EverGuard® TPO coated drains are constructed using GAF’s proven, durable EverGuard® TPO coated onto a durable drain unit. • Cost effective… Reduces installed costs by up to 25%• Improved Reliability… Factory– built accessories reduce risk of leaks and callbacks• Improved Aesthetics… Uniform look Application EverGuard® TPO coated accessories are designed for use with GAF EverGuard® TPO single- ply membranes and EverGuard® Freedom™ TPO self-adhering membranes. The factory-coated accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® TPO roofing systems. See current application and specifications manual for detailed instructions. Product Information EverGuard® TPO coated drains are constructed from aluminum and coated with a weldable TPO compound. TPO membrane can be heat welded directly to the drain body, resulting in a strong, secure installation. Each drain is fitted with a BlueSeal® mechanical drain seal for a secure, tight seal into the building drain system. Available Sizes EverGuard® TPO Coated Metal Drains are available in two sizes: • 3" drain will fit into a 3" ID pipe • 4" drain will fit into a 4" ID pipe gaf.com Fluted Corner Inside Corner TPO Coated Metal Drain Vent Boot Universal Corner Vent CoatedAccessories Also Available... ©2013 GAF • 1/13 • #468 COMEG178 We protect what mat ters most™ Visit gaf.com ©2 0 2 2 G A F 7 / 2 2 • # 4 6 8 • C O M E G 8 2 8 - P D F TPO Accessories RTA Strip Description: EverGuard ® TPO Roof Transition Anchor (RTA) Strip provides roofing contractors with an easy-to-install prefabricated detail. EverGuard® TPO RTA Strip is constructed from durable GAF EverGuard ® TPO. Application: The 6" x 100' (152 mm x 30.5 m) 45- mil reinforced TPO membrane with pressure-sensitive adhesive can be installed on horizontal surfaces, using plates and fasteners as a base attachment in adhered systems. Features and Benefits: n Helps reduce installed costs n Prefabricated accessories can help reduce the risk of installation errors n Constructed with GAF TPO for a uniform look Product Details: Specifications n Roll Length – 100' (30.5 m) n Roll Width – 6" (152 mm) Shipping Specifications n Rolls per Case: 2 n Weight per Case: 34.9 lb. (15.83 kg) n Cases per Pallet: 27 Product SKUs n White: 8585920 Roof Transition Anchor EverGuard®TPORTAStrip Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com ©2 0 2 4 G A F • C O M E G 8 4 4 - P D F - 0 8 2 4 TPO Accessory Description: Protect rooftop membranes exposed to repeated foot traffic with EverGuard® TPO Walkway Roll. Used around HVAC areas, hatches, doors, and other access points, it features a raised diamond pattern for enhanced traction and smooth edges for better welding. Factory-built accessories reduce risk of leaks and callbacks, and help create a uniform aesthetic. This easy-to-install accessory saves time and labor costs, and creates a uniform aesthetic. Application: n Heat weld EverGuard® TPO Walkway Roll to the roof membrane surface continuously around the walkway roll perimeter. Rolls must be spaced at least six inches (152 mm) apart to allow for drainage. n EverGuard® TPO Walkway Roll is designed for use with EverGuard® TPO single-ply membranes and with EverGuard Extreme® and EverGuard® TPO self-adhering membranes. n The factory-coated accessories may be installed on mechanically attached, fully adhered, or self- adhered EverGuard® TPO roofing and specifications manual for detailed instructions. Product Information: EverGuard® TPO Walkway Roll is made from EverGuard® and recycled TPO. The roll measures 34" x 50' (864 mm x 15.24 m), and the diamond pattern measures 30" (762 mm) with 2” smooth sides for welding. Rolls provide 140-mil thickness and are available in standard gray or safety yellow. Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com TPO Accessories ©2 0 2 4 G A F • C O M E G 8 4 3 - P D F - 0 4 2 4 Description: Save time and labor costs with factory- built, easy-to-install EverGuard® TPO 6" Cover Tape. Used for stripping-in TPO end laps and edge metal, this factory- built accessory reduces risk of leaks and callbacks, and helps create a uniform aesthetic. Application: Use soap and water to clean the membrane end lap area or edge metal surface to be covered. Dry the area then wipe it down with a white cloth moistened with EverGuard® TPO Seam Cleaner. Brush or roll EverGuard® TPO Primer onto each surface, carrying approximately three inches (76 mm) past the ends. Ensure the primer has properly dried or “flashed off” before applying EverGuard® TPO 6" Cover Tape with a silicone roller. Product Information: Self-adhering EverGuard® TPO 6" Cover Tape is non-reinforced TPO membrane that is six inches (152 mm) wide and backed with a butyl tape adhesive. Store material in original unopened packaging at temperatures between 40°F – 110°F (4°C – 43°C). Product shelf life is 24 months when stored as recommended. SPECIFICATIONS Roll Length 100' (30.5) Roll Width 6" (152 mm) SHIPPING SPECIFICATIONS Rolls per case 2 Weight per case 37.4 lb. (16.96 kg) Cases per pallet 36 PRODUCT SKU White 755A920 Tan 755A820 Gray 755A345 Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com ©2 0 2 4 G A F • C O M E G 8 4 6 - P D F - 0 4 2 4 TPO Accessories Visit gaf.com Codes and Compliance: n Texas Department of Insurance n ICC-ES n State of Florida Approved* n UL Listed Accessory n Miami-Dade County Product Control Approved *EverGuard® TPO only For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Description: Increase efficiency when covering metal edges with factory-built EverGuard® and EverGuard Extreme® TPO Heat-Weldable Cover Tape. This single-ply roofing system accessory provides roofing contractors with an effective, easy-to-install component. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard Extreme® TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Clean and prime metal with EverGuard® TPO Primer. Allow primer to dry or flash off. Apply the self-adhering side to the metal and the heat-weldable side to the roofing membrane. See published application and specifications manual for detailed instructions. Product Information: EverGuard® and EverGuard Extreme® TPO Heat-Weldable Cover Tape is constructed from EverGuard® or EverGuard Extreme® reinforced 45-mil membrane. One package contains two 100’ long, 6” wide rolls with a 3” self-adhered area and a 3” heat-weldable area. Specifications TPO Heat-Weldable Cover Tape Roll length 100' Roll width 6" Shipping Specifications Rolls per box 2 Weight per box 34 lb. / 15.42 kg Boxes per pallet 27 Product SKUs EverGuard® TPO EverGuard Extreme® TPO White 85P8920 85P8776 We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 8 4 5 - P D F - 0 8 2 3 TPO Accessories Description: Increase efficiency when flashing irregular penetrations with factory-built EverGuard® and EverGuard Extreme® TPO Split Pourable Sealer Pockets. These single-ply roofing system preformed accessories provide roofing contractors with an effective, easy- to-install detail. GAF manufactures these accessories from a proprietary formulation designed for use with GAF EverGuard® and EverGuard Extreme® TPO single-ply membranes. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Preformed accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard Extreme® TPO roofing systems, using conventional techniques. See published application and specifications manual for detailed instructions. For additional information, contact GAF Technical Support at 1-877-423-7663 or designservices@gaf.com Specifications Total width of pocket 19" (483 mm) Total length of pocket 25" (635 mm), can be cut to 19" (483mm) Height of pocket walls 2" (51 mm) Shipping Specifications Box size 24" (610 mm) x 19.5" (405 mm) x 13.5" (343 mm) Pieces per box 6 complete pockets Weight per box 6 lb. (2.72 kg) Boxes per pallet 12 Pallet size 48" (1,219 mm) x 48" (1,219 mm) Product SKU EverGuard®EverGuard Extreme® White 800B920NC 800C776NC Product Information: EverGuard® and EverGuard Extreme® TPO Split Pourable Sealer Pockets are engineered for use with GAF EverGuard® and EverGuard Extreme® TPO single-ply membranes. They eliminate the need for contractors to fabricate a pitch pocket in the field. The split design lets you cut the pocket to better fit irregular penetrations, therefore requiring less sealant. Fill these right-sized pockets with EverGuard® TPO One-Part Pourable Sealant. n Establish 2” (52 mm) clearance around the projection. For areas with multiple projections, allow 1” (25.4 mm) between projection and pocket. n Clean all dust and debris from the projection area. n Install four Drill-Tec™ plates and screws surrounding the projection. n If the two-piece pocket doesn't fit tightly, cut each piece along one of their marked lines for a better fit, which also reduces the amount of EverGuard® One-Part Pourable Sealant required. n Heat-weld the entire flange (preferred). n When not welding the entire flange (optional), weld a minimum 2" perimeter along the outside of the flange and ensure sealant does not migrate by either applying a bead of GAF FlexSeal™ Caulk Grade Sealant along the inside seam where the pocket meets the roof or a thin layer of non-shrink quick-set grout across the entire roof area inside the pocket. n Heat-weld the upright portion of the two pocket sections together with a minimum 2" weld. n Prime every surface of the pocket (inside and out) that will contact the sealant, as well as pipes, concrete, etc. within the pocket, with EverGuard® TPO Seam Cleaner or EverGuard® TPO Cleanweld Conditioner. n Fill the pocket with the pourable sealant, slightly overflowing to ensure a complete fill. Note: Pourable sealant is considered a maintenance item, therefore is excluded from guarantee coverage. Installation: Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com ©2 0 2 4 G A F • C O M E G 1 6 6 - P D F - 0 4 2 4 TPO Accessories Description: Increase efficiency when covering pipes with factory-built EverGuard® and EverGuard Extreme® TPO Split Pipe Boots. These single-ply roofing system preformed accessories provide roofing contractors with an effective, easy-to- install detail. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard Extreme® TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Preformed accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard Extreme® TPO roofing systems, using conventional techniques. See published application and specifications manual for detailed instructions. Specifications Diameter 1" (25 mm) – 2" (51 mm) 3" (76 mm) – 5" (127 mm) 6" (152 mm) – 8" (203 mm) Shipping Specifications 1" – 2"3" – 5"6" – 8" Boots per box 6 Weight per bpx 7.5 lb.7.5 lb.11 lb. Boxes per pallet 36 36 24 Product SKUs EverGuard® TPO 85G6920 85G7920 85G8920 EverGuard Extreme® TPO 81E1776 85G2776 81E3776 Product Information: Extreme® TPO Split Pipe Boots are constructed from EverGuard® or EverGuard Extreme® reinforced 45-mil membrane. Three standard sizes are available, and you can contact your local GAF representative for custom sizes. The split design lets you wrap them around pipes and conduit where closed boots cannot be used. Grey Bar For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Visit gaf.com TPO Accessories ©2 0 2 4 G A F • C O M E G 1 6 5 - P D F - 0 4 2 4 For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Description: Increase efficiency when covering square or rectangular pipes with factory-built EverGuard® and EverGuard Extreme® TPO Square Tube Wraps. These single-ply roofing system preformed accessories provide roofing contractors with an effective, easy-to-install detail. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard Extreme® TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Preformed accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard Extreme® TPO roofing systems, using conventional techniques. See published application and specifications manual for detailed instructions. Product Information: EverGuard® and EverGuard Extreme® TPO Square Tube Wraps are constructed from EverGuard® or EverGuard Extreme® reinforced 45-mil membrane. Three standard sizes are available and you can contact your representative for custom sizes. Wraps include stainless steel clamping rings for the top of the penetration. Specifications Size 4" (102 mm) x 4" (102 mm) 4" (102 mm) x 6" (152 mm) 6" (152 mm) x 6" (152 mm) Pieces per box 6 Weight per box 4" x 4" (6 lb)4" x 6" (6.5 lb)6" x 6" (7 lb) Boxes per pallet 24 Product SKUs EverGuard® TPO EverGuard Extreme® TPO 4" x 4"8506920 81E06776 4" x 6"8508920 81E08776 6" x 6"8507920 81E07776 Description EverGuard® TPO single-ply roofing system preformed accessories provide roofing contractors an easy-to-install, factory-built detail. EverGuard® preformed accessories are constructed from GAF’s proven, durable EverGuard® TPO single-ply reinforced membrane. UÊÊ œÃÌÊivviV̈ÛioÊÊ Reduces installed costs UÊÊ“«ÀœÛi`ÊÀiˆ>LˆˆÌÞo Factory-built accessories reduce risk of leaks and callbacks UÊÊ“«ÀœÛi`Ê>iÃ̅ïVÃoÊÊ Uniform look Application EverGuard® TPO Corner Curb Wraps are designed for use with GAF EverGuard® TPO single-ply membranes. Corner Curb Wraps may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® TPO roofing systems. Corner Curb Wraps are installed using conventional heat-welding techniques. Product Information EverGuard® Corner Curb Wraps are constructed from EverGuard® reinforced 45 mil TPO membrane. Four standard sizes of Corner Curb Wraps are available. Each Corner Curb Wrap is 12" in height and has a 6" base area for welding to field membrane. UÊÛ>ˆ>Liʈ˜Ê{ÊÃÌ>˜`>À`ÊÈâià UÊÛ>ˆ>Liʈ˜Ê܅ˆÌi]Ê}À>Þ]Ê>˜`ÊÌ>˜ UÊ ÕÃ̜“ÊÈâiÃÊ>ÃœÊ>Û>ˆ>LiI gaf.com ÕÌi`Ê œÀ˜iÀ ˜Ãˆ`iÊ œÀ˜iÀ œÀ˜iÀÊ ÕÀLÊ7À>« SPECIFICATIONS Height: 12” Base: 6” Length: 13.5”, 19.5”, 25.5”, 31.5” SHIPPING SPECIFICATIONS Curbs per box: 4 Weight per box: 13.5” 5.6 lbs. 19.5” 7.4 lbs. 25.5” 10.7 lbs. 31.5” 12.5 lbs. Boxes per pallet: 32 PRODUCT SKUs White 13.5” 85F2920 White 19.5” 85F3920 White 25.5” 85F4920 White 31.5” 85F5920 Also Available... ¥("'rr $0.&( *ÀivœÀ“i`ÊVViÃÜÀˆià 6i˜ÌÊ œœÌ 1˜ˆÛiÀÃ>Ê œÀ˜iÀ 6i˜Ì I œ˜Ì>VÌÊޜÕÀʏœV>ÊÀi«ÀiÃi˜Ì>̈ÛiÊvœÀÊ`iÌ>ˆÃ° We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 1 6 2 - P D F - 0 1 2 3 TPO Accessories Description: Increase efficiency when covering outside corners with factory-built EverGuard® and EverGuard® Extreme TPO Fluted Corners. These single-ply roofing system molded accessories provide roofing contractors with an effective, easy-to-install detail. GAF manufactures these and other molded accessories using a proprietary formulation designed for use with GAF’s EverGuard® and EverGuard® Extreme TPO single-ply membranes. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Molded accessories may be installed on mechanically attached, fully adhered or, self-adhered EverGuard® and EverGuard® Extreme TPO roofing systems, using conventional techniques. See published application and specifications manual for detailed instructions. For additional information, contact GAF Technical Support at 1-800-766-3411 or technicalquestions@gaf.com Specifications Diameter 8" (203 mm) Nominal thickness .050" (1.3 m) Shipping Specifications Qty per box 20 Weight per box 2.5 lb. / 1.1 kg Boxes per pallet 250 Product SKUs EverGuard®EverGuard® Extreme TPO Fluted Corner White 8A00920WA 8A00776GA TPO Fluted Corner Tan 8A00820WA N/A TPO Fluted Corner Grey 8A00345WA N/A Product Information: EverGuard® and EverGuard® Extreme TPO Fluted Corners are molded from a proprietary TPO formulation engineered to work with EverGuard® and EverGuard® Extreme TPO single- ply membranes. Fluted Corners are manufactured with a nominal thickness of 50 mils, and they allow for ease of welding in tight areas, as well as flashing of non-uniform corners. We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 1 9 0 - P D F - 0 1 2 3 TPO Accessories Description: Increase efficiency when covering corners with factory-built EverGuard® and EverGuard® Extreme TPO Fluted Corners. These single-ply roofing system molded accessories provide roofing contractors with an effective, easy-to-install detail. GAF manufactures these and other molded accessories using a proprietary formulation designed for use with GAF EverGuard® and EverGuard® Extreme TPO single-ply membranes. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks while helping you create a uniform look. Application: Molded accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard® Extreme TPO roofing systems using conventional techniques. Simply cut the standard size at markings to produce either inside or outside corner reinforcements. See published application and specifications manual for detailed instructions. For additional information, contact GAF Technical Support at 1-800-766-3411 or technicalquestions@gaf.com Specifications Dimensions 3" x 3" (76 mm x 76 mm) with 6" (152 mm) flange Thickness .070" (1.78 mm) Shipping Specifications Qty per box 20 Weight per box 9 lb. / 4.08 kg Boxes per pallet 232 Product SKUs EverGuard®EverGuard® Extreme White 7730920CU 7731776CU Product Information: EverGuard® and EverGuard® Extreme TPO Universal Corners accommodate inside and outside corners of base and curb flashings. Universal Corners are manufactured with a thickness of 60 mils. Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com ©2 0 2 4 G A F • C O M E G 8 4 1 - P D F - 0 4 2 4 TPO Accessories Description: EverGuard® TPO Yellow Safety Tape helps make a roof safer for everyone who needs to access it. It provides a highly visible warning to take caution around a variety of potential hazards: n Edges n Skylights n Expansion joints n Solar panels n Other rooftop features EverGuard® TPO Yellow Safety Tape is easy to install and lasts for years while requiring less maintenance than many paint coatings that perform the same function. Application: Clean the entire surface to be covered with soap and water, and dry thoroughly. Wipe the area to be primed with a white cloth moistened with of EverGuard® TPO Seam Cleaner. Apply EverGuard® TPO Primer on surfaces mating with the butyl tape — only on the surfaces receiving the tape. After the primer has dried, pull a portion of the release paper on the back of the tape, exposing the butyl adhesive, and mate the two surfaces. Roll the tape portion of the cover strip at a 45-degree angle to ensure a good bond.* * See EverGuard® Application and Specifications Manual for detailed application instructions and additional information on Yellow Safety Tape and Cover Tape. Product Information: EverGuard® TPO Yellow Safety Tape is a 6"- (152 mm) wide by 100'- (30.48 m) long cover tape made from nominal 30 mil unreinforced TPO. It can be used in conjunction with EverGuard® Yellow Walkway Rolls. SPECIFICATIONS Width 6" (152 mm) Length 100' (30.48 m) SHIPPING SPECIFICATIONS Qty per box 2 Weight per box 38 lb. / 17.24 kg Boxes per pallet 36 PRODUCT SKU TPO Yellow Safety Tape 755F902 Also Available: We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 1 9 5 - P D F - 0 1 2 3 TPO Accessories Description: Increase efficiency when covering T-joints with factory-built EverGuard® and EverGuard® Extreme TPO T-Joint Cover Patches. These single-ply roofing system preformed accessories provide roofing contractors with an effective, easy-to- install detail. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard® Extreme TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: T-Joint Cover Patches can be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard® Extreme TPO roofing systems, using conventional techniques. See published application and specifications manual for detailed instructions. For additional information, contact GAF Technical Support at 1-800-766-3411 or technicalquestions@gaf.com Specifications Membrane thickness .055" (1.40 mm) Unit size 4" x 4" (102 mm x 102 mm) Shipping Specifications Patches per carton 100 Weight per carton 3.3 lb. (1.5 kg) Cartons per pallet 196 Product SKUs EverGuard ® TPO EverGuard ® Extreme TPO T-Joint Cover Patch White 7712920 771277GA T-Joint Cover Patch Gray 7712345 N/A T-Joint Cover Patch Tan 7712820 N/A Product Information: EverGuard® T-Joint Cover Patches are created from a proprietary TPO formulation engineered for ease of welding over all EverGuard® TPO single-ply membranes. Manufactured to 55-mil thickness, EverGuard® TPO T-Joint Cover Patches create a membrane seal over T-joints that arise when installing a 60-, 70-, or 80-mil EverGuard® TPO system. We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 1 6 0 - P D F - 0 2 2 3 TPO Accessories Description: Increase efficiency when covering pipes and conduits with factory-built EverGuard® and EverGuard Extreme® TPO Vent Boots. These single-ply roofing system preformed accessories provide roofing contractors with an effective, easy-to-install detail. GAF manufactures these and other accessories from its proven, durable EverGuard® and EverGuard Extreme® TPO single- ply reinforced membrane. GAF TPO accessories can help you reduce installation costs, risk of leaks, and callbacks, while helping you create a uniform look. Application: Preformed accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard Extreme® TPO roofing systems, using conventional techniques. See published application and specifications manual for detailed instructions. For additional information, contact GAF Technical Support at 1-800-766-3411 or technicalquestions@gaf.com Specifications EverGuard® TPO EverGuard Extreme® TPO Membrane thickness .075" (1.9 mm).065" (1.7 mm) For pipe sizes 1" x 6" (25.4 mm x 152.4 mm) Shipping Specifications Boots per carton 6 Weight per carton 9 lb. (4.1 kg) Cartons per pallet EverGuard® (54) EverGuard® Extreme (48) Product SKUs EverGuard® TPO EverGuard Extreme® TPO Vent Boot White 7710920CU 7710776CU Product Information: EverGuard® and EverGuard Extreme® TPO Vent Boots are constructed from EverGuard® or EverGuard Extreme® reinforced membrane. One standard size accommodates 1" – 6" (25.4 mm – 152.4 mm) pipes and conduits. Vent Boots come with stainless steel clamping rings for the top of the penetration. We protect what mat ters most™ Visit gaf.com ©2 0 2 4 G A F • C O M E G 9 8 5 - P D F - 0 3 2 4 TPO Accessories Description: Increase efficiency when covering pipes and conduits with factory-built EverGuard® Self-Adhered TPO Vent Boots. These single-ply roofing system preformed accessories provide roofing contractors with an effective, easy-to-install detail. GAF manufactures these and other accessories from its proven, durable EverGuard® TPO single-ply reinforced membrane. GAF TPO accessories can help you reduce installation labor, risk of leaks, and callbacks, while helping you create a uniform look. Installation Instructions: 1. Roof membrane must be mechanically attached at the base of each penetration with four fasteners and plates. 2. If plates and fasteners intrude into boot flange area, a TPO target must FIRST be installed over plates and fasteners 3. TPO must be cleaned with EverGuard® TPO Seam Cleaner or EverGuard® TPO Low VOC Seam Cleaner and allowed to fully flash off. Note: Aged membrane with visible contaminants may need to be cleaned first with a household cleaner. 4. Prime the TPO field membrane with EverGuard® TPO Primer and allow it to fully flash off. 5. Remove release liner on the Self-Adhered Vent Boot to expose adhesive. 6. Install EverGuard® Water-Block on the penetration where it will meet the top of the pipe boot. 7. Install the Self-Adhered Vent Boot over the vent pipe. 8. Using a silicone hand roller, adhere the flange onto the membrane. Where the Self-Adhered Vent Boot is installed over field seams, slightly heat the pipe boot flange while firmly rolling the flange. Take care to “crease-in” the Self-Adhered Vent Boot over the seams. Note: Do not cut the side of the pre-molded Self-Adhered Vent Boot. It must be pulled over the vent pipe. 9. Install a bead of FlexSeal™ Caulk Grade Sealant around entire perimeter lap of the Self-Adhered Vent Boot for 20 year coverage under the GAF EverGuard Diamond Pledge NDL Roof Guarantees; 15 year guarantee coverage available otherwise.* 10. Install the stainless steel draw band around the top of the Self-Adhered Vent Boot, then add FlexSeal™ Caulk Grade Sealant around the top of the draw band. Read full application instructions at gaf.com before using or installing this product. * Additional requirements apply. Contact GAF for more information. Benefits: GAF Self-Adhered TPO Accessories can be installed without welding, which means: n Easier installation n Lower experience level required n Great for repairs n Time savings Application: Preformed accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® and EverGuard Extreme® TPO roofing systems. For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Specifications Membrane thickness .075" (1.9 mm) For pipe sizes 1" − 6" (25.4 mm − 152.4 mm) Shipping Specifications Boots per carton 6 Weight per carton 9 lb. (4.1 kg) Cartons per pallet EverGuard® (54) Shelf Life 18 months from the date of manufacture when stored properly Product SKUs Vent Boot White 77B01920NC Product Information: EverGuard® Self-Adhered TPO Vent Boots are constructed from EverGuard® reinforced membrane. One standard size accommodates 1" – 6" (25.4 mm – 152.4 mm) pipes and conduits. Vent Boots come with stainless steel clamping rings for the top of the penetration. gaf.com Description EverGuard® TPO single-ply roofing system molded accessories provide roofing contractors an easy-to-install, factory-built detail. EverGuard® molded accessories are manufactured using a proprietary formulation designed for use with GAF’s EverGuard® TPO single-ply membranes. UÊÊ œÃÌÊivviV̈ÛioÊÊ Reduces installed costsUÊÊ“«ÀœÛi`ÊÀiˆ>LˆˆÌÞo Factory-built accessories reduce risk of leaks and callbacksUÊÊ“«ÀœÛi`Ê>iÃ̅ïVÃoÊÊ Uniform look Application EverGuard® TPO molded accessories are designed for use with GAF EverGuard® TPO single-ply membranes and EverGuard® Freedom™ TPO self-adhering membranes. The molded accessories may be installed on mechanically attached, fully adhered, or self-adhered EverGuard® TPO roofing systems. EverGuard® molded accessories are installed using conventional techniques. See published application and specifications manual for detailed instructions. Product Information EverGuard® Inside Corners are molded from a proprietary TPO formulation engineered to work with EverGuard® TPO single-ply membranes. Inside Corners allow for fast flashing of base and curb corners. UÊ>˜Õv>VÌÕÀi`Ê̜Ê>VVœ““œ`>Ìiʈ˜Ãˆ`iÊVœÀ˜iÀÃʜvÊ L>ÃiÊ>˜`ÊVÕÀLÊv>ň˜}à UÊ iÈ}˜i`ÊvœÀÊi>ÃiʜvÊÜi`ˆ˜}ʈ˜Ê̈}…ÌÊ>Ài>ÃÊ UʘÈ`iÊ œÀ˜iÀÃÊ>ÀiÊvœÀ“i`ÊÕȘ}Ê՘Àiˆ˜vœÀVi`Ê “i“LÀ>˜iÊ̜Ê>ʘœ“ˆ˜>ÊxäʓˆÊ̅ˆVŽ˜iÃÃÊÊ ÕÌi`Ê œÀ˜iÀ -«ˆÌÊ*ˆ«iÊ œœÌ ˜Ãˆ`iÊ œÀ˜iÀ SPECIFICATIONS Membrane thickness: .050” Corner dimensions: 6” x 6” x 5 1/4” SHIPPING SPECIFICATIONS 20 corners per carton: 3.5 lbs./carton Cartons per pallet: 54 œ`i`ÊVViÃÜÀˆià Also Available... ¥("'rr$0.&( PRODUCT SKUs Inside Corner White 8509920WA Inside Corner Grey 8509345WA Inside Corner Tan 8509820WA 6i˜ÌÊ œœÌ 1˜ˆÛiÀÃ>Ê œÀ˜iÀ 6i˜Ì We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M E G 8 7 1 - P D F - 0 5 2 3 TPO Accessories Description: Use this low-VOC product to help prepare TPO for heat-welding by cleaning exposed or contaminated seams, removing any residual soap or other cleaners, and revitalizing aged or weathered membranes. The VOC content is 50 grams/liter. Application: Minimal contamination: Membrane that has been exposed overnight or for only a few days to airborne debris, foot traffic, dew, or light precipitation can usually be cleaned with a white cloth moistened with EverGuard® TPO Cleanweld Membrane Conditioner. Be sure to wait for the cleaner to properly dry or flash off before welding. Dirt contamination: Membrane that is dirt-encrusted should first be cleaned with a mildly abrasive scrubbing pad and a non-abrasive, non-bleach, low-residue cleaner. After the dirt has been removed, the membrane must be cleaned with a white cloth moistened with EverGuard® TPO Cleanweld Membrane Conditioner. Be sure to wait for the solvent to properly dry or flash off before welding. For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Specifications Can size 1 gallon Shipping Specifications Cans per carton 6 Weight per case 52.6 lb. (23.8 kg) Cases per pallet 48 Product SKU 7789000WP Weathering: Membrane that is weathered or oxidized should first be cleaned with a mildly abrasive scrubbing pad and EverGuard® TPO Cleanweld Membrane Conditioner. After the weathered or oxidized top layer is removed, the membrane must be cleaned with a white cloth moistened with EverGuard® TPO Cleanweld Membrane Conditioner. Be sure to wait for the solvent to properly dry or flash off before welding. Note: The same procedure may be needed for unexposed membrane left in inventory for a year or longer. Bag fresh: Do not use EverGuard® TPO Cleanweld Membrane Conditioner on recently opened or “bag fresh” material that has been exposed for less than 12 hours, unless that material has been otherwise contaminated. Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com TPO Accessories ©2 0 2 4 G A F • C O M E G 8 4 0 - P D F - 0 4 2 4 Description: Help prepare TPO for heat-welding by cleaning exposed or contaminated seams, removing any residual soap or other cleaners, and revitalizing aged or weathered membranes. Application: Minimal contamination: Membrane that has been exposed overnight or for only a few days to airborne debris, foot traffic, dew, or light precipitation can usually be cleaned with a white cloth moistened with EverGuard® TPO Seam Cleaner. Be sure to wait for the cleaner to properly dry or flash off before welding. Dirt contamination: Membrane that is dirt-encrusted should first be cleaned with a mildly abrasive scrubbing pad and a non-abrasive, non-bleach, low-residue cleaner. After the dirt has been removed, the membrane must be Storage Notes: Apply EverGuard® TPO Seam Cleaner where the ambient temperature is 40°F (4°C) and rising. Store in a clean and well-ventilated area where the ambient temperature is 40°F (4°C) – 90°F (32.2°C). Do not allow to freeze. The cleaner shelf life is 12 months from date of manufacture when properly stored. The VOC content is 861 grams/liter. SPECIFICATIONS Can size 1 Gallon Cans per carton 4 Weight per case 33 lb. (14.96 kg) Cases per pallet 48 Product SKU 7793 cleaned with a white cloth moistened with EverGuard® TPO Seam Cleaner. Be sure to wait for the cleaner to properly dry or flash off before welding. Weathering: Membrane that is weathered or oxidized should first be cleaned with a mildly abrasive scrubbing pad and EverGuard® TPO Cleaner. After the weathered or oxidized top layer is removed, the membrane must be cleaned with a white cloth moistened with EverGuard® TPO Seam Cleaner. Be sure to wait for the cleaner to properly dry or flash off before welding. Note: The same procedure may be needed for unexposed membrane left in inventory for a year or longer. Bag fresh: Do not use EverGuard® TPO Seam Cleaner on recently opened or “bag fresh” material that has been exposed for less than 12 hours, unless that material has been otherwise contaminated. Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com TPO Accessories ©2 0 2 4 G A F • C O M E G 8 3 6 - P D F - 0 4 2 4 Codes and Compliance: n Miami-Dade County Product Control Approved Description: EverGuard® TPO Primer and EverGuard® TPO Low VOC Primer are vital to surface preparation. Rely on GAF EverGuard® Primer and Low VOC Primer to help prepare metal and membrane for application of cover tape, and to help prepare membrane and pourable sealer pockets to apply EverGuard® One-Part Pourable Sealant. Temperature: Apply the primer at an ambient air temperature of 40° F (4° C) and rising. Shelf Life: Primer shelf life is 12 months (18 months for Low VOC) from date of manufacture if unopened and properly stored. Application: Cover Tape When installing cover tape, apply the primer with a 3" roller to both the metal and membrane. Allow the primer to flash off before applying the tape. HW Cover Tape When installing heat weld cover tape, apply the primer with a 3" roller to the metal only. Allow the primer to flash off before applying heat weld cover tape. Pourable Sealant Pocket Prior to filling the TPO Pourable Sealant Pocket, you must prime all areas that the one-part pourable sealant will come in contact with. Storage and Handling: When not in use, ensure covers are securely in place. Store primers in a clean, well-ventilated space at 40°F (4°C) – 90°F (32.2°C). Improper sealing or storage for continued periods outside of this temperature range may shorten shelf life. SPECIFICATIONS TPO Primer Low VOC TPO Primer* Can size 1 gallon 1 gallon Cans per carton 6 6 Coverage Rates 200 – 250 sq. ft. per gallon (18.6 – 23.2 m2 per liter) 200 – 225 sq. ft. per gallon (18.6 – 20.9 m2 per liter) Product SKUs 755B 755D * Maximum VOC <250g/L EverGuard® TPOPrimer Grey Bar Visit gaf.com For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com TPO and PVC One-Part Pourable Description: EverGuard® One-Part Pourable Sealant is a one-part, moisture-cure, self-levelling sealant designed for use in sealant pockets on single-ply roof systems. Since moisture-cure sealants cure with moisture in the air, it is suitable for application in damp and cold climates, as well as in dry climates. EverGuard® One-Part Pourable Sealant is formulated without solvents, contains no isocyanates, and will not shrink upon curing. It does not “outgas” or bubble on damp surfaces. EverGuard® One-Part Pourable Sealant is elastomeric and has excellent adhesion to most roofing materials and penetrations. It has a low durometer, which accommodates greater movement in penetration seals. Uses: EverGuard® One-Part Pourable Sealant is designed for use with the EverGuard® Pourable Sealer Pocket on new and existing TPO, PVC, and PVC KEE roofs to seal irregular penetrations, such as metal frames, wires, and pipes. Note: EverGuard® TPO Primer is required to prime the TPO surface before use. No primer is necessary for PVC or PVC KEE. Advantages: n Formulated without solvents — less than 25 g/L VOC n 100% solids by volume — will not shrink n No outgassing on damp surfaces n Self-levelling provides a smooth, professional finished look n UV stable n 20-minute skinover time at 70°F (22°C) and 50% relative humidity. n Typically paintable within 24 hours. High humidity or cold temperatures may slow dry time. n No special tools or mixing required n Application at temperatures as low as 30°F (-1°C) VOC Compliance: n Meets requirements of OTC rule for sealants and caulks n Meets requirements of California’s SCAQMD rule, the most stringent in the state Product Information: LEED® 4.1 BD+C: New Construction: n Contributes to Low-Emitting Materials Credit VOC Content: n Less than 25 grams/liter ASTM D2369 EPA Method 24 (tested at 240°F [115°C]) Typical Properties VOC (max)<25 grams/liter Service Temperature -40°F (-40°C) to 200°F (93.3°C) Full Cure Rate of cure is dependent on atmospheric conditions. Curing proceeds at a rate of ¼" (6.35 mm) a week at 70°F (22°C) and 50% relative humidity. Lower temperature and humidity will slow the rate of cure. Higher tempera- ture and humidity will accelerate rate of cure. Depths of more than 2" (51 mm) will cure through in 2 to 3 months. Skin Time Approximately 20 minutes at 70°F (22°C) and 50% relative humidity. Shrinkage 0% Tensile Strength 146 lbf (217 kg/m) Elongation 300% ± 25% Density 8.9 ± .2 lb. per gallon (1.068 g/ml) We protect what mat ters most™ Visit gaf.com ©2 0 2 4 G A F • C O M E G 1 8 1 - P D F - 0 4 2 4 Application Instructions: Surface should be clean, dry, and free of any loose materials. Remove all previously applied caulk, mastic, cement, and other contaminants from penetrations with a cleaner. All roof deck voids are to be filled with FlexSeal™ Sealant. Prime all surfaces (except Everguard® PVC or EverGuard® PVC KEE) with EverGuard® TPO Primer. Allow primer to dry prior to applying EverGuard® One-Part Pourable Sealant. Fill the EverGuard® Pourable Sealer Pocket with EverGuard® One-Part Pourable Sealant to the top of the pocket, ensuring that all voids are filled. See GAF’s published application and specifications manual for complete details. Cure Time: EverGuard® One-Part Pourable Sealant is a moisture-cure sealant. Rate of cure is dependent on atmospheric conditions. Curing proceeds at a rate of ¼" (6 mm)a week at 70°F (22°C) and 50% relative humidity. Lower temperature and humidity will slow the rate of cure. Higher temperature and humidity will accelerate rate of cure. Depths of more than 2" (51 mm) will cure through in 2 to 3 months. Precautions: n Do not apply at temperatures below 30°F (-1°C). n Do not use on TPO without EverGuard® TPO Primer. n Do not use on Hypalon® membranes. n Do not install if rain is anticipated within four hours. n Do not use in areas subject to continuous water immersion. n Do not use in areas where prolonged chemical exposure is anticipated. n Do not prime bonding surfaces with asphalt primer. n Use GAF FlexSeal™ Caulk Grade Sealant as a “night sealant” around the base of the penetration. Do not use petroleum-based solvents, such as mineral spirits, for cleaning purposes. n Maintain sealant at room temperature before applying to ensure easy pouring and levelling. n Test and evaluate to ensure adequate adhesion. n Dry all visible and standing water prior to applying sealant. Application Temperature: EverGuard® One-Part Pourable Sealant can be applied at temperatures as low as 30°F (-1°C). In these colder temperatures, it is recommended to keep the material stored inside or in a truck before using. Packaging: n 0.53 gallon (2 L) pouch n 4 pouches/case n 48 cases/pallet n Color: White Storage n Recommended storage is between 40°F–90°F (4°C–32.2°C). Store unopened containers in a cool, dry area. Protect unopened containers from water, heat, and direct sunlight. Although EverGuard® One-Part Pourable Sealant will not freeze, it is recommended to store indoors before using to ensure easy gunning and levelling. Clean-up: Wet adhesive can be removed using a solvent, such as alcohol. Cured EverGuard® One-Part Pourable Sealant can be removed by abrading or scraping the substrate. Shelf Life: One year from date of manufacture when stored in recommended conditions. Elevated temperature and high relative humidity may significantly reduce shelf life. Grey Bar For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com ©2 0 2 4 G A F • C O M E G 3 7 5 - P D F - 1 1 2 4 Low-VOC TPO Spray Adhesive Codes and Compliance: 3 Sq. and 10 Sq. Canisters Only n Classified by UL in accordance with ANSI/UL 790.* n FM Approved* n State of Florida Approved * Refer to UL Product iQ for specific assemblies. Refer to RoofNav.com for actual assemblies. Description: EverGuard® TPO Quick Spray Adhesive LV50 is a low-VOC, sprayable, solvent-based contact adhesive useful for bonding smooth EverGuard® and EverGuard Extreme® TPO membranes to various substrates. Features and Benefits: n Faster installation than traditional bucket and roller bonding adhesive n High initial tack n 2-year shelf life from the date of manufacture n Available in 3 sq. and 10 sq. canisters (Expected coverage rate when installed in accordance with application instructions) n Aerosol can size available for easy carrying and application Application: n Substrate should be dry, clean, and free from oil, grease, and other contaminants. n When spraying canister-sized EverGuard® TPO Quick Spray Adhesive LV50, the GAF Hose & Gun SKU 7804 or 7805 — which utilize a 11002 spray tip — must be used in order to help achieve the proper coverage rate as well as to avoid contamination with non-GAF adhesives, which could impact performance. No Hose & Gun unit required for aerosol can size n For TPO Membrane, apply adhesive uniformly to both the substrate and the underside of the membrane. (See pictures for proper coverage.) n Canister: Spray from 8" – 12" (203 mm to 305 mm) away n Aerosol: Spray from 6" – 8" (152 mm to 203 mm) away n Allow adhesive to dry to a tacky feel before bonding membrane to substrate. n Apply pressure with a push broom and weighted roller to ensure complete bonding. When using aerosol version, apply pressure with a hand roller to ensure complete bonding. n Apply at an ambient temperature of 20°F (-6.7°C) and above. The cylinders/ cans must be kept above 50°F (10°C) for the product to spray properly. Utilize power-heated blankets and hot boxes when necessary. When installing at 40°F and below, flash-off may take longer but the mating window may be shorter. The application must be carefully monitored to ensure proper timing when mating the membrane and substrate. Ensure that cylinder/cans temperatures stay below 150°F (65.6°C). n To clean Hose & Gun Kit, attach hose and gun to the EverGuard® Quick Spray LV50 Cleaning Kit and run cleaner through hose and gun for approximately 10 – 15 seconds. Each canister of cleaner will provide 9 – 10 gun and hose cleanings. Product Information: n Canister: VOC: <90 g/L n Can: VOC <55% n Installation Temperature: 20°F (-6.7°C) and rising SKU numbers 3 Square GW 16 lb. (7.3 kg)7807 10 Square GW 40 lb. (18.1 kg)7801 14.2 oz aerosol can, 12 cans per carton 7801A Cleaner 7803 12' Hose & Gun 7804 or 7805 25' Hose 7825 Note: Coverage area assumes application in accordance with GAF instructions. Just right: Not enough: Too much: Coverage Information: ©2017 GAF 7/17 gaf.com • 1-800-ROOF-411 Description Drill-Tec™ #12 Fastener is designed to secure insulation to steel (18 ga. – 24 ga.) and wood. It is available in lengths from 1-5/8" – 8" (41.3 mm – 203 mm). The Drill- Tec™ Standard #12 Roofing Fastener is Factory Mutual and Miami-Dade County Product Control approved. Application The Drill-Tec™ #12 Fastener must pen- etrate steel decks a minimum of ¾" (19.1 mm), wood plank decks a minimum of 1" (25.4 mm), and ½" (12.7 mm) through the underside for plywood decks. Using a screw gun, drive the fastener until the screw head is seated securely; with very rigid insulation boards, watch for the plate to dimple. Note: Be careful not to overdrive the fastener and fracture the skin of the insu- la- tion. Fastener must be tight enough so that the plate doesn’t turn. For steel decks, Factory Mutual requires that the fastener penetrate the deck at the top flute. To speed installation, this fastener is also available as a labor saving assembled screw and plate. See Drill-Tec ASAP® 3S. Code Approvals Advantages • Heavier shank & thread diameters than most “standard” roofing fasteners. • Deep buttress thread for high pull-out resistance. • Extra sharp drill point for quick instal- lation in new or reroof applications. • Available with Hex Head or #3 Phillips Truss Head. Plates & Accessories • Use 3" (76 mm) steel or plastic plates, depending upon the application. • For best installation results, use a variable speed 0-2500 rpm screw gun. Specifications The fastener will be a Drill-Tec™ #12 Fastener with a thread diameter of .220" (5.58 mm). The fastener must have 12.5 buttress threads per inch (per 25.4 mm) and a 30° drill point. Also, the fastener must be heat treated per specification OMG-1. The Drill-Tec™ #12 Fastener will be used with a Factory Mutual-approved, Drill-Tec™ Round Pressure Plate or Pressure Bar. The fastener must be Factory Mutual approved. Coating Requirement The fastener will be coated with the Drill-Tec™ CR-10 corrosion-resistant coat- ing. When subjected to 30 Kesternich cycles (DIN 50018), the fastener must show less than 15% red rust and surpass Factory Mutual Approval Standard 4470. Note: ASAP® is a registered trademark of OMG. DRILL-TEC™ #12 FASTENER Example: Drill-Tec™ #12 Fastener Length Selection Procedure 1. If applicable, determine thickness of existing roofing material. 2. Add thickness of new insulation. 3. Add 3/4” (19.1 mm) minimum fastener penetration. 4. If odd size requirement, always size up in length, not down. See example below. Example Use this format to calculate correct fastener size: Existing Roofing: 1 ¾" (44.4 mm)Existing Roof: New Insulation: + ½" (12.7 mm) New Insulation:+ Min. Embedment: + ¾" (19.1 mm)Min. Embedment:+ ¾" (19.1 mm) Total Fastening Range: = 3" (76 mm)Total Fastening Range:= The proper #12 Fastener for the example is 3 1/4" (82.6 mm).The proper #12 Fastener is: Drill-Tec™ #12 Fastener Length Thread Length Packaging (Bucket)Weight 1 5/8" (41.3mm)Full 1,000 12 lb (5.44 kg) 2 1/4" (57.1 mm)Full 1,000 15 lb (7.71 kg) 3" (76 mm)Full 1,000 24 lb (10.89 kg) 4" (102 mm)3" (76 mm)1,000 28 lb (12.70 kg) 5" (127 mm)3" (76 mm)1,000 35 lb (15.88 kg) 6" (152 mm)4" (102 mm)1,000 40 lb (18.14 kg) 7" (178 mm)4" (102 mm)1,000 48 lb (21.77 kg) 8" (203 mm)4" (102 mm)1,000 50 lb (22.68 kg) Product Data Thread Diameter .220" (5.58 mm) Head Diameter Truss Head .435" (11.04 mm) Hex Head .390" (9.91 mm) Head Style #3 Phillips Truss Head* 1/4" (6.35 mm) Hex Head* Coating CR-10 * #3 Phillips bit or Hex Head drive included in each bucket. Note: All sizes are nominal. ©2017 GAF 7/17 gaf.com • 1-800-ROOF-411 Description Drill-Tec™ #14 Fastener is designed to secure insulation to heavy steel decks (18 ga.– 20 ga.), wood decks, and structural concrete. It is available in lengths from 1-1/4" – 16" (31.8 – 406 mm). The Drill-Tec™ #14 Fastener is Factory Mutual and Miami-Dade County Product Control approved. Application The Drill-Tec™ #14 Fastener must pen- etrate steel decks a minimum of ¾" (19.1 mm), wood plank decks a minimum of 1" (25.4 mm), and ½" (12.7 mm) through the underside for plywood decks. The Drill- Tec™ #14 Fastener requires a minimum embedment of 1" (25.4 mm) penetration into structural concrete. Predrill a 3/16" (4.76 mm) pilot hole using a carbide-tip SDS bit. The predrilled pilot hole must be a minimum of ½" (12.7 mm) deeper than the fastener embedment (at least a 2" [51 mm] deep pilot hole recommended). Using a screwshooter, drive the fastener until the screw head is seated securely; with very rigid insulation boards, watch for the plate to dimple. Note: Be careful not to overdrive the fastener and fracture the skin of the insu- lation. Fastener must be tight enough so that the plate doesn’t turn. Code Approvals Advantages • Heavier shank & thread diameters than most “heavy duty” roofing fasteners. • Deep thread for high pull-out resistance. • Extra sharp drill point for quick installa- tion in new or reroof applications. Plates & Accessories • Use 3" (76 mm) steel or plastic plates, depending upon the application. • For best installation results, use a vari- able speed 0-2500 rpm screw gun. Specifications The fastener will be a Drill-Tec™ #14 Fastener with a shank diameter of .190 (.423 mm) and a thread diameter of .245 (6.22 mm). The fastener must have 10 threads per inch (per 25.4 mm) and have a 30° drill point. Also, the fastener must be heat treated per specification OMG-1. The Drill-Tec™ #14 Fastener will be used with a Factory Mutual- approved, Drill-Tec™ Round Pressure Plate. The fastener must be Factory Mutual approved. Coating Requirement The fastener will be coated with the Drill-Tec™ CR-10 corrosion-resis- tant coating. When subjected to 30 Kesternich cycles (DIN 50018), the fastener must show less than 15% red rust and surpass Factory Mutual Approval Standard 4470. DRILL-TEC™ #14 FASTENER Example: Drill-Tec™ #14 Fastener Length Selection Procedure 1. If applicable, determine thickness of existing roofing material. 2. Add thickness of new insulation. 3. Add ¾" (19.1 mm) minimum fastener penetration. 4. If odd size requirement, always size up in length, not down. See example below. Example Use this format to calculate correct fastener size: Existing Roofing: 1 ¾" (44.4 mm) Existing Roof: New Insulation: + ½" (12.7 mm) New Insulation:+ Min. Embedment: + ¾" (19.1 mm) Min. Embedment:+ ¾" (19.1 mm) Total Fastening Range: = 3" (76 mm)Total Fastening Range:= The proper #14 Fastener for the example is 3" (76 mm).The proper #14 Fastener is: Drill-Tec™ #14 Fastener Length Thread Length Packaging Weight 1 1/4" (31.8 mm)Full 1,000*13 lb (5.90 kg) 1 3/4" (44.4 mm)Full 1,000*17 lb (7.71 kg) 2" (51 mm)Full 1,000*19 lb (8.62 kg) 3" (76 mm)Full 1,000*27 lb (12.25 kg) 4" (102 mm)3" (76 mm)1,000*35 lb (15.88 kg) 5" (127 mm)4" (102 mm) 500*23 lb (10.43 kg) 6" (152 mm)4" (102 mm) 500*26 lb (11.79 kg) 7" (178 mm)4" (102 mm) 500*30 lb (13.61 kg) 8" (203 mm)4" (102 mm) 500*34 lb (15.42 kg) 9" (227 mm)4" (102 mm) 500**37 lb (16.78 kg) 10" (254 mm)4" (102 mm) 500**40 lb (18.14 kg) 11" (279 mm)4" (102 mm) 500**44 lb (19.96 kg) 12" (305 mm)4" (102 mm) 250**25 lb (11.34 kg) 14" (357 mm)4" (102 mm) 250**29 lb (13.15 kg) 16" (406 mm)4" (102 mm) 250**38 lb (17.24 kg) 18" (457 mm)4" (102 mm) 250**41 lb (18.6 kg) 20" (508 mm)4" (102 mm) 250** 47 lb (21.32 kg) 22" (558.8 mm)4" (102 mm) 250**51 lb (23.13 kg) 24" (609 mm)4" (102 mm) 250**56 lb (24.4 kg) *Bucket **Box Longer Lengths Available Upon Request. Call GAF For Information. Product Data Thread Diameter .245" (6.22 mm) Shank Diameter .190" (.423 mm) Head Diameter .435" (11.04 mm) Head Style #3 Phillips Truss Head* Coating CR-10 *#3 Phillips bit included in each carton or bucket We protect what mat ters most™ Visit gaf.com ©2 0 2 4 G A F • C O M D T 2 3 5 - P D F - 1 0 2 4 Description: Drill-Tec™ insulation plates are made of Galvalume®-coated steel for excellent corrosion protection. Also available in a 3" Plastic Locking Plate made of durable polypropylene to be used with the Drill-Tec™ #12 or Drill-Tec™ #14 fasteners. The plates meet the requirements of ASTM D6294, FM Approval Standard 4470, and DIN 50018. They are ideal for attaching both insulation and cover boards. Round Plates: The round design distributes loads evenly, eliminates sharp corners that can damage the insulation or cover board, and are available in a flat profile, which is ideal for cover boards, as well as recessed profile. These plates are designed to be used with appropriate Drill-Tec™ fasteners, depending on the substrate type. For details on fasteners and substrates please see the GAF attachment tables for TPO and PVC. Square Plates: AccuTrac® Plates are designed to be used in the AccuTrac® Stand Up Tool, offering an ergonomic fastening solution for attaching insulation and cover boards. They are available in two designs, recessed and flat. Please refer to GAF-published application instructions for approved substrates and additional information requirements at gaf.com. For applications not listed or for additional information, contact GAF at 877-423-7663 or designservices@gaf.com. Galvalume® is a registered trademark of BIEC International Inc. and some of its licensed producers. AccuTrac® is a registered trademark of OMG. For additional information, contact GAF Design Services at 1-877-423-7663 or designservices@gaf.com Product Data Plate Drill-Tec™ 3" (76 mm) Standard Steel Plate Drill-Tec™ 3" (76 mm) Steel Plate Drill-Tec™ 3" (76 mm) Ribbed Galvalume® Plate (Flat) Drill-Tec™ 3" (76 mm) AccuTrac ® Flat Plate Drill-Tec™ 3" (76 mm) AccuTrac ® Recessed Plate Drill-Tec™ 3" (76 mm) Plastic Locking Plate Plate Profile Material/ Coating AZ-55 Galvalume®Polypropylene Dimensions (Diam./Width)3" (76 mm) Packaging 500 per box 1,000 per bucket 1,000 per bucket 1,000 per bucket 1,000 per bucket 1,000 per box Weight 37 lb. (16.7 kg) 37 lb. (16.7 kg) 37 lb. (16.7 kg) 43 lb. (19.5 kg)43 lb. (19.5 kg)25 lb. (11.34 kg) FM Approved ✓✓✓✓✓✓ Miami-Dade County Product Control Approved ✓✓✓✓✓✓ State of Florida Approved ✓✓✓✓✓✓ Codes and Standards: n FM Approved per Approval Standard 4470. Refer to RoofNav.com for specific assemblies. State of Florida Approved GAF Attachment Tables for TPO and PVC Drill-Tec™ 3" (76 mm) Plastic Locking Plate Drill-Tec™ 3" (76 mm) Ribbed Galvalume® Plate (Flat) Flat Recessed Drill-Tec™ 3" (76 mm) Steel Plate Drill-Tec™ 3" (76 mm) AccuTrac® Flat Plate Drill-Tec™ 3" (76 mm) AccuTrac® Recessed Plate Drill-Tec™ 3" (76 mm) Standard Steel Plate We protect what mat ters most™ Visit gaf.com ©2 0 2 3 G A F • C O M D T 2 4 2 - P D F - 1 1 2 3 Description: Drill-Tec™ membrane seam plates are made of Galvalume® coated steel for excellent corrosion protection. The plates meet the requirements of ASTM D6294, FM 4470, and DIN 50018. They are ideal for attaching both TPO and PVC single-ply membranes. The round design distributes loads evenly, eliminates sharp corners that can damage the membrane, and provides strong uplift resistance. These plates are designed to be used with appropriate Drill-Tec™ fasteners depending on the substrate type. For details on fasteners and substrates please see the GAF attachment tables for TPO and PVC. Please refer to GAF-published application instructions for approved substrates and additional information requirements at gaf.com. For applications not listed or for additional information, contact GAF at 877-423-7663 or designservices@gaf.com. Galvalume® is a registered trademark of BIEC International Inc. and some of its licensed producers. For additional information, contact GAF Technical Support at 1-800-766-3411 or technicalquestions@gaf.com Product Data Plate Drill-Tec™ 2 in. (51 mm) Double Barbed XHD Plate Drill-Tec™ 2 3/8 in. (60.3 mm) Barbed XHD Plate Drill-Tec™ 2 3/8 in. (60.3 mm) Double Barbed XHD Plate Drill-Tec™ Eyehook AccuSeam Plate Drill-Tec™ 2 3/4 in. (69.9 mm) Barbed SXHD Plate Material/ Coating AZ-55 Galvalume Diameter 2” (51 mm)2 3/8” (60.3 mm) 2 3/8” (60.3 mm) 2 3/8” (60.3 mm) 2 3/4” (69.9 mm) Packaging 1,000 per bucket 1,000 per bucket 1,000 per box 1,000 per bucket 500 per box Weight 33 lb. (14.9 kg) 45 lb. (20.4 kg) 52 lb. (23.5 kg) 48 lb. (21.7 kg) 37 lb. (16.8 kg) FM Approved ✓✓✓✓✓ Miami Dade Approved ✓✓✗✓✓ FBC Approved ✓✓✗✓✓ Codes and Compliance: n FM Approved per Approval Standard 4470. Refer to RoofNav.com for specific assemblies. State of Florida Approved GAF Attachment Tables for TPO and PVC Drill-Tec™ 2 3⁄4 in. (69.9 mm) Barbed SXHD Plate Drill-Tec™ Eyehook AccuSeam Plate Drill-Tec™ 2 3/8 in. (60.3 mm) Double Barbed XHD Plate Drill-Tec™ 2 3/8 in. (60.3 mm) Barbed XHD Plate Drill-Tec™ 2 in. (51 mm) Double Barbed XHD Plate GAF Safety Data Sheet SDS # 1088 SDS Date: February 2024 _________________________________________________________________________ Page 1 of 7 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: EnergyGuard™ Tapered Polyiso Insulation EnergyGuard™ Polyiso Insulation EnergyGuard™ HD Plus Coverboard EnergyGuard™ HD Coverboard EnergyGuard™ Ultra Polyiso Insulation EnergyGuard™ Ultra Tapered Polyiso Insulation EnergyGuard™ HD-MA Polyiso Cover Board CHEMICAL NAME: Polyisocyanurate MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800 – 424 – 9300 INFORMATION ONLY: 877 – GAF– ROOF APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. ADDITIONAL HAZARD IDENTIFICATION INFORMATION: PRIMARY ROUTE OF EXPOSURE: Inhalation, Skin Contact. SIGNS & SYMPTOMS OF EXPOSURE EYES: May cause irritation to the eyes. SKIN: May cause irritation to the skin. GAF SDS # 1088 Page 2 of 7 INGESTION: Not applicable. INHALATION: Exposure to dust may cause irritation. Processes such as cutting, grinding, crushing, or impact may result in generation of excessive amounts of airborne dusts in the workplace. Nuisance dust may affect the lungs but reactions are typically reversible. ACUTE HEALTH HAZARDS: None known. CHRONIC HEALTH HAZARDS: No data available. CARCINOGENICITY: Not applicable. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % OSHA ACGIH OTHER Isopentane 78-78-4 4.5 - 9.9 1000 ppm 600 ppm REL: 120 ppm n-Pentane 109-66-0 <0.1 - 5.5 1000 ppm 600 ppm REL: 120 ppm Tris (monochloropropyl) Phosphate 13674-84-5 <1 - 8 NE NE NE Fibrous Glass None <25 NE 1 f/cc REL: 3 f/cc NE = Not Established Balance of other ingredients are non-hazardous or less than 1% in concentration (or 0.1% for carcinogens, reproductive toxins, or respiratory sensitizers). GAF SDS # 1088 Page 3 of 7 SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Hold eyelids open and wash with gentle stream of water for at least 15 minutes preferably at eyewash fountain. SKIN: Wash affected area thoroughly with soap and water. INHALATION: Remove to fresh uncontaminated air. INGESTION: Rinse mouth. Do not give anything by mouth to an unconscious person. Consult medical personnel. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: No information available SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Water spray, alcohol foam, carbon Dioxide, or dry chemical. HAZARDOUS COMBUSTION PRODUCTS: Carbon dioxide and carbon monoxide, phosphorus oxides, and phosphoric acid. RECOMMENDED FIRE FIGHTING PROCEDURES: Wear impermeable protective clothing and self-contained breathing apparatus. Toxic fumes and vapors may be evolved. UNUSUAL FIRE & EXPLOSION HAZARDS: Emits dense, black smoke when burned. Certain operations such as grinding or cutting may lead to a buildup of dust suspended in air which can cause a dust explosion if ignited. Isopentane and n-pentane, highly flammable materials, may be present within this product. Provide adequate ventilation and appropriate dust handling systems. SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: Use only in well ventilated areas. Wear appropriate personal protective equipment. Pick up large pieces. Sweep and scoop up material and put into a suitable container for disposal as a non-hazardous waste. SECTION 7: HANDLING AND STORAGE GAF SDS # 1088 Page 4 of 7 HANDLING AND STORAGE: Use only in a well-ventilated area. Wear appropriate personal protective equipment. Protect against dust that may be generated by altering or applying this product. Minimize dust generation and accumulation. Routine housekeeping should be carried out to ensure that dusts do not accumulate on surfaces. Wash thoroughly with soap and water after handling and before eating, drinking or using tobacco products. OTHER PRECAUTIONS: None. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Use local mechanical ventilation. RESPIRATORY PROTECTION: Respiratory protection may be needed when mechanically manipulating this product (sawing, cutting, etc.). If respiratory protection is selected, a NIOSH-approved dust mask or respirator should be worn. EYE PROTECTION: Safety glasses with side shields SKIN PROTECTION: Cotton or leather gloves are recommended when handling. OTHER PROTECTIVE EQUIPMENT: Wear long sleeves and/or protective coveralls if determined to be needed by the end-user. WORK HYGIENIC PRACTICES: Wash exposed skin prior to eating, drinking or smoking and at the end of each shift. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: White rigid cellular sheets/odorless. FLASH POINT: No Data LOWER EXPLOSIVE LIMIT: No Data METHOD USED: No Data UPPER EXPLOSIVE LIMIT: No Data EVAPORATION RATE: No Data BOILING POINT: No Data pH (undiluted product): No Data MELTING POINT: No Data SOLUBILITY IN WATER: No Data SPECIFIC GRAVITY: No Data VAPOR DENSITY: No Data PERCENT VOLATILE: No Data VAPOR PRESSURE: No Data MOLECULAR WEIGHT: No Data GAF SDS # 1088 Page 5 of 7 VOC WITH WATER (LBS/GAL): No Data WITHOUT WATER (LBS/GAL): No Data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE ☐ CONDITIONS TO AVOID (STABILITY): None known. INCOMPATIBILITY (MATERIAL TO AVOID): None known. HAZARDOUS DECOMPOSITION OR BY-PRODUCTS: Carbon dioxide and carbon monoxide HAZARDOUS POLYMERIZATION: Will not occur. _________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: Pentane (0.05% TO 5.5%) 109-66-0 Acute Toxicity: Ingestion/Oral-Rat LD50 • >2000 mg/kg; Inhalation-Rat LC50 • 364 g/m³ 4 Hour(s) Isopentane (4.5% TO 9.9%) 78-78-4 Acute Toxicity: Inhalation-Rat LC50 • 280000 mg/m³ 4 Hour(s) Route(s) of entry/exposure - Inhalation, Skin, Eye, Ingestion Medical Conditions Aggravated by Exposure - Disorders of the lungs. Potential Health Effects Inhalation Acute (Immediate) - Exposure to dust may cause irritation. Processes such as cutting, grinding, crushing, or impact may result in generation of excessive amounts of airborne dusts in the workplace. Nuisance dust may affect the lungs but reactions are typically reversible. Chronic (Delayed) - No data available Skin Acute (Immediate) - Exposure to dust may cause mechanical irritation. Chronic (Delayed) - No data available. Eye Acute (Immediate) - Exposure to dust may cause mechanical irritation. Excessive concentrations of nuisance dust in the workplace may reduce visibility and may cause unpleasant deposits in eyes. Chronic (Delayed) - No data available. Ingestion Acute (Immediate) - Excessive concentrations of nuisance dust in the workplace may cause mechanical irritation to mucous membranes. GAF SDS # 1088 Page 6 of 7 Chronic (Delayed) - No data available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. _________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: Dispose of content and/or container in accordance with local, regional, national, and/or international regulations. SECTION 14: TRANSPORTATION INFORMATION DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA: Not applicable. SARA Not applicable. 311 / 312 HAZARD CATEGORIES: Not applicable. 313 REPORTABLE INGREDIENTS: Not applicable. SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: November 2022 CHANGES SINCE PREVIOUS SDS: Updated Section 1 GAF SDS # 1088 Page 7 of 7 This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 2001 SDS Date: May 2023 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: EverGuard® TPO (All Thicknesses) TPO FB Membranes and Accessories (UN Detailing Membrane) Coated Metal Membrane Pre-Formed Corners & Vent Boots Split Pourable Sealer Pocket Flashing Strips UN T-Patches EverGuard® TPO Coated Drain. MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800–424–9300 INFORMATION ONLY: 877-GAF-ROOF APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed above are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. PRIMARY ROUTE OF EXPOSURE: None SIGNS & SYMPTOMS OF EXPOSURE EYES: Not Applicable SKIN: Minimize direct contact during handling particularly at high ambient temperatures as the adhesive can be aggressive on the skin. INGESTION: Not Applicable INHALATION: Not Applicable ACUTE HEALTH HAZARDS: Not Applicable CHRONIC HEALTH HAZARDS: Not Applicable CARCINOGENICITY: Not Applicable SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER Trade Secret - 100 NE NE NE NE = Not Established SECTION 3: HAZARDS IDENTIFICATION PRIMARY ROUTE OF EXPOSURE: None SIGNS & SYMPTOMS OF EXPOSURE EYES: Not Applicable SKIN: Minimize direct contact during handling particularly at high ambient temperatures as the adhesive can be aggressive on the skin. INGESTION: Not Applicable INHALATION: Not Applicable ACUTE HEALTH HAZARDS: Not Applicable CHRONIC HEALTH HAZARDS: Not Applicable CARCINOGENICITY: Not Applicable SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Flush with water for 15 minutes. Remove contact lenses if worn. Consult with medical personnel if irritation persists. SKIN: Not normally hazardous. If contact is made at elevated temperatures treat as a thermal burn. INHALATION: Noxious fumes can be emitted from the release liner if heated to its melting point. If inhaled at elevated temperatures, remove to fresh air. Seek medical assistance. INGESTION: If ingested, induce vomiting. Consult medical personnel. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: Not Applicable SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Carbon dioxide, dry chemical HAZARDOUS COMBUSTION PRODUCTS: Carbon dioxide, carbon monoxide, methane, propane, aldehydes and other organic vapors. RECOMMENDED FIRE FIGHTING PROCEDURES: Use self-contained breathing apparatus and suitable protective clothing. UNUSUAL FIRE & EXPLOSION HAZARDS: The release liner will continue to burn even when the original source of combustion is removed. SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: None SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Store rolls on their sides on pallets or shelving in a dry area. Membrane rolls are heavy. Position and install by at least two people. OTHER PRECAUTIONS: None SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: None RESPIRATORY PROTECTION: Not Applicable EYE PROTECTION: Safety glasses with side shields. SKIN PROTECTION: Gloves are recommended. OTHER PROTECTIVE EQUIPMENT: When handling this material, wear long sleeve shirts, long pants and safety shoes. WORK HYGIENIC PRACTICES: Washing of hands is recommended after handling coated sheets. EXPOSURE GUIDELINES: Not Applicable SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Thin sheet in roll form, various colors. Negligible odor. FLASH POINT: No data LOWER EXPLOSIVE LIMIT: No data METHOD USED: No data UPPER EXPLOSIVE LIMIT: No data EVAPORATION RATE: No data BOILING POINT: No data pH (undiluted product): No data MELTING POINT: 350 °F SOLUBILITY IN WATER: Insoluble SPECIFIC GRAVITY: 0.9 – 1.2 VAPOR DENSITY: No data PERCENT VOLATILE: No data VAPOR PRESSURE: No data MOLECULAR WEIGHT: No data VOC WITH WATER (LBS/GAL): No data WITHOUT WATER (LBS/GAL): No data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE CONDITIONS TO AVOID (STABILITY): Do not store near strong oxidizers or open flames. INCOMPATIBILITY (MATERIAL TO AVOID): Avoid contact of adhesive with strong oxidizing agents. HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: Carbon dioxide, carbon monoxide, methane, propane, aldehydes and other organic vapors. HAZARDOUS POLYMERIZATION: Will not occur. SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: Dispose in accordance with all applicable local, state and Federal regulations. SECTION 14: TRANSPORTATION INFORMATION DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA: Not Applicable SARA 311/312 HAZARD CATEGORIES: Not Applicable 313 REPORTABLE INGREDIENTS: Not Applicable CALIFORNIA PROPOSITION 65: Not Applicable SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: June 2022 CHANGES SINCE PREVIOUS SDS: Section 1 This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 2003 SDS Date: August 2018 _________________________________________________________________________ Page 1 of 6 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: EVERGUARD TPO Coated Metal Flashing TRADE NAME: Coated Metal Flashing – TPO2PLUS MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800 – 424 – 9300 INFORMATION ONLY: 800 – 766 – 3411 PREPARED BY: Corporate EHS APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. PRIMARY ROUTE OF EXPOSURE: None known under normal use. SIGNS & SYMPTOMS OF EXPOSURE EYES: None SKIN: None INGESTION: None INHALATION: None ACUTE HEALTH HAZARDS: None GAF SDS # 2003 Page 2 of 6 CHRONIC HEALTH HAZARDS: None CARCINOGENICITY: None Known SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER 1-Propene, polymer with Ethene 09010-79-1 NE NE NE Metal N/A NE NE NE NE = Not Established SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Not Applicable. SKIN: Not Applicable. INHALATION: Not Applicable. INGESTION: Not Applicable. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: None SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Carbon Dioxide, Dry Chemical HAZARDOUS COMBUSTION PRODUCTS: Carbon Monoxide, carbon dioxide, methane, propane, aldehydes and other organic vapor. RECOMMENDED FIRE FIGHTING PROCEDURES: Use self-contained breathing apparatus and protective clothing. UNUSUAL FIRE & EXPLOSION HAZARDS: None GAF SDS # 2003 Page 3 of 6 SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: None SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: None OTHER PRECAUTIONS: None SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Not Applicable. RESPIRATORY PROTECTION: Not Applicable. EYE PROTECTION: Safety glasses SKIN PROTECTION: Work gloves OTHER PROTECTIVE EQUIPMENT: None WORK HYGIENIC PRACTICES: None EXPOSURE GUIDELINES: None SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Plastic coated metal with no odor. FLASH POINT: No Data LOWER EXPLOSIVE LIMIT: No Data METHOD USED: No Data UPPER EXPLOSIVE LIMIT: No Data EVAPORATION RATE: No Data BOILING POINT: No Data pH (undiluted product): No Data MELTING POINT: No Data SOLUBILITY IN WATER: Non-soluble SPECIFIC GRAVITY: No Data GAF SDS # 2003 Page 4 of 6 VAPOR DENSITY: No Data PERCENT VOLATILE: No Data VAPOR PRESSURE: No Data MOLECULAR WEIGHT: No Data VOC WITH WATER (LBS/GAL): No Data WITHOUT WATER (LBS/GAL): No Data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE CONDITIONS TO AVOID (STABILITY): None INCOMPATIBILITY (MATERIAL TO AVOID): None HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: Carbon Monoxide, carbon dioxide, methane, propane, aldehydes and other organic vapor. HAZARDOUS POLYMERIZATION: Will not occur. __________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. __________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: This product, as supplied, is not regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. Comply with state and local regulations for disposal. RCRA HAZARD CLASS: None SECTION 14: TRANSPORTATION INFORMATION GAF SDS # 2003 Page 5 of 6 U.S. DOT TRANSPORTATION PROPER SHIPPING NAME: This product is not classified as a hazardous material for transport. HAZARD CLASS: Not Applicable. ID NUMBER: Not Applicable. PACKING GROUP: Not Applicable. LABEL STATEMENT: Not Applicable. OTHER: Not Applicable. SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA: Not Applicable. SARA 311/312 HAZARD CATEGORIES: Not Applicable. 313 REPORTABLE INGREDIENTS: Not Applicable. CALIFORNIA PROPOSITION 65: Not Applicable. Other state regulations may apply. Check individual state requirements. The following components appear on one or more of the following state hazardous substances lists: Chemical Name CAS # CA MA MN NJ PA RI 1-Propene, polymer with Ethene 09010-79-1 No No No No No No SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: Not Applicable. DATE OF PREVIOUS SDS: December 2013 CHANGES SINCE PREVIOUS SDS: Headquarters Address Change GAF SDS # 2003 Page 6 of 6 This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 2271 SDS Date: June 2018 _________________________________________________________________________ Page 1 of 6 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: EverGuard® TPO RTA (Roof Transition Anchor) Strip MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800-424-9300 INFORMATION ONLY: 800-766-3411 PREPARED BY: Corporate EHS APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. ADDITIONAL HAZARD IDENTIFICATION INFORMATION: PRIMARY ROUTE OF EXPOSURE: Eye Contact SIGNS & SYMPTOMS OF EXPOSURE EYES: Can cause irritation to eyes. SKIN: Not likely to occur. INGESTION: Not likely to occur. INHALATION: Not likely to occur. ACUTE HEALTH HAZARDS: See above. GAF SDS # 2271 Page 2 of 6 CHRONIC HEALTH HAZARDS: None known CARCINOGENICITY: None listed. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER Non-hazardous ingredients N/A 100 NE NE NE NE = Not Established SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Treat as a foreign object in the eye. Flush with large amounts of water, frequently flushing under the lids. Get medical attention if irritation persists. SKIN: Not likely to be needed. INHALATION: Not likely to be needed. INGESTION: Not likely to be needed. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: None known. SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Foam, water, dry chemical or carbon dioxide. HAZARDOUS COMBUSTION PRODUCTS: Carbon dioxide and carbon monoxide. RECOMMENDED FIRE FIGHTING PROCEDURES: Limit fire fighting to those trained to do so. Minimize breathing gases, vapor, fumes or decomposition products. Use supplied air breathing equipment for enclosed or confined spaces or as otherwise needed. UNUSUAL FIRE & EXPLOSION HAZARDS: None known. GAF SDS # 2271 Page 3 of 6 SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: Shovel or scoop into a sealable container for disposal. SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Avoid prolonged or repeated contact with skin. Avoid contact with eyes. Wash thoroughly after handling. Store in a cool location away from direct heat. OTHER PRECAUTIONS: Store away from oxidizing agents. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Not needed under normal conditions. RESPIRATORY PROTECTION: Not needed under normal conditions. EYE PROTECTION: Safety glasses with side shields are recommended. SKIN PROTECTION: Not needed under normal conditions. OTHER PROTECTIVE EQUIPMENT: Not needed under normal conditions. WORK HYGIENIC PRACTICES: Avoid prolonged or repeated contact with the skin. W ash with soap and water after contact with product. EXPOSURE GUIDELINES: N/A SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: White solid roll with a tacky strip. No odor. FLASH POINT: No data LOWER EXPLOSIVE LIMIT: No data METHOD USED: No data UPPER EXPLOSIVE LIMIT: No data EVAPORATION RATE: No data BOILING POINT: No data GAF SDS # 2271 Page 4 of 6 pH (undiluted product): No data MELTING POINT: No data SOLUBILITY IN WATER: Insoluble SPECIFIC GRAVITY: No data VAPOR DENSITY: No data PERCENT VOLATILE: No data VAPOR PRESSURE: No data MOLECULAR WEIGHT: No data VOC WITH WATER (LBS/GAL): No data WITHOUT WATER (LBS/GAL): No data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE CONDITIONS TO AVOID (STABILITY): Heat, flames, sparks, hot surfaces, ignition sources. INCOMPATIBILITY (MATERIAL TO AVOID): None known. HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: In the event of partial combustion, fumes, smoke, carbon dioxide and carbon monoxide. HAZARDOUS POLYMERIZATION: Will not occur. _________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. _________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: This product, as supplied, is not regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. Comply with state and local regulations for disposal. RCRA HAZARD CLASS: None GAF SDS # 2271 Page 5 of 6 SECTION 14: TRANSPORTATION INFORMATION DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: None of the ingredients is listed. CERCLA: None SARA 311/312 HAZARD CATEGORIES: None 313 REPORTABLE INGREDIENTS: None CALIFORNIA PROPOSITION 65: None Other state regulations may apply. Check individual state requirements. The following components appear on one or more of the following state hazardous substances lists: Chemical Name CAS # CA MA MN NJ PA RI Non-hazardous ingredients N/A No No No No No No SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: October 2013 CHANGES SINCE PREVIOUS SDS: Updated version. GAF SDS # 2271 Page 6 of 6 This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 2005 SDS Date: August 2018 _________________________________________________________________________ Page 1 of 7 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: EverGuard TPO Walkway Rolls MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800 – 424 – 9300 INFORMATION ONLY: 800 – 766 – 3411 PREPARED BY: Corporate EHS APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. ADDITIONAL HAZARD INDENTIFICATION INFORMATION: PRIMARY ROUTE OF EXPOSURE: None known under normal use. SIGNS & SYMPTOMS OF EXPOSURE EYES: None SKIN: None INGESTION: None INHALATION: None ACUTE HEALTH HAZARDS: None GAF SDS # 2005 Page 2 of 7 CHRONIC HEALTH HAZARDS: None CARCINOGENICITY: Titanium Dioxide is classified as a 2B carcinogen (possibly carcinogenic to humans) by the International Agency for Research on Cancer (IARC). Carbon Black is classified as a 2B carcinogen (possibly carcinogenic to humans) by the International Agency for Research on Cancer (IARC). SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER Titanium Dioxide 13463-67-7 <1.0 15 mg/m3 – total 10 mg/m3 – total REL: lowest feasible concentration Carbon Black 1333-86-4 <0.01 3.5 mg/m3 3.5 mg/m3 REL: 3.5 mg/m3 Calcium Carbonate 1317-65-3 15 - 20 5 mg/m3 – resp. 15 mg/m3 – total 3 mg/m3 – resp. 10 mg/m3 – total REL: 5 mg/m3 – resp., 10 mg/m3 – total Poly [[6-[ 1,1,3,3- tetramethylbuty1])a mino]-striazine- 2,4-diy1][2,2,6,6- tetramethy1-4- piperidy1)imino]hex amethylene[(2,2,6,6 -tetrame 70624-18-9 <.35 NE NE NE NE = Not Established GAF SDS # 2005 Page 3 of 7 SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Dust particles that may occur may irritate the eyes. SKIN: Dust particles that may occur may irritate the skin. INHALATION: Inhalation of dust particles may irritate the respiratory system. INGESTION: N/A NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: N/A SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Carbon Dioxide, Water Fog, Foam HAZARDOUS COMBUSTION PRODUCTS: Carbon Monoxide and Carbon Dioxide RECOMMENDED FIRE FIGHTING PROCEDURES: Use routine fire fighting procedures UNUSUAL FIRE & EXPLOSION HAZARDS: Thermal oxidative decomposition may yield carbon monoxide, carbon dioxide and low molecular weight hydrocarbons. SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: None SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Sweep/clean up and dispose of material in accordance with good housekeeping practices. OTHER PRECAUTIONS: None SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / N/A GAF SDS # 2005 Page 4 of 7 VENTILATION: RESPIRATORY PROTECTION: N/A EYE PROTECTION: Safety glasses SKIN PROTECTION: Work gloves OTHER PROTECTIVE EQUIPMENT: None WORK HYGIENIC PRACTICES: Use the normal precautions taken in handling and cutting flexible rubber or plastic materials. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Composite plastic structure with no odor. FLASH POINT: No Data LOWER EXPLOSIVE LIMIT: No Data METHOD USED: No Data UPPER EXPLOSIVE LIMIT: No Data EVAPORATION RATE: <1 BOILING POINT: No Data pH (undiluted product): No Data MELTING POINT: No Data SOLUBILITY IN WATER: Insoluble SPECIFIC GRAVITY: .97 – 1.01 VAPOR DENSITY: No Data PERCENT VOLATILE: No Data VAPOR PRESSURE: No Data MOLECULAR WEIGHT: No Data VOC WITH WATER (LBS/GAL): No Data WITHOUT WATER (LBS/GAL): No Data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE CONDITIONS TO AVOID (STABILITY): None INCOMPATIBILITY (MATERIAL TO AVOID): None HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: None HAZARDOUS POLYMERIZATION: Will not occur. GAF SDS # 2005 Page 5 of 7 __________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. __________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: This product, as supplied, is not regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. Comply with state and local regulations for disposal. RCRA HAZARD CLASS: None SECTION 14: TRANSPORTATION INFORMATION U.S. DOT TRANSPORTATION PROPER SHIPPING NAME: This product is not classified as a hazardous material for transport. HAZARD CLASS: N/A ID NUMBER: N/A PACKING GROUP: N/A LABEL STATEMENT: N/A OTHER: N/A SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS GAF SDS # 2005 Page 6 of 7 TSCA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA: N/A SARA 311/312 HAZARD CATEGORIES: N/A 313 REPORTABLE INGREDIENTS: N/A CALIFORNIA PROPOSITION 65: This product contains a chemical known to the state of California to cause cancer and birth defects, or other reproductive harm. Other state regulations may apply. Check individual state requirements. The following components appear on one or more of the following state hazardous substances lists: Chemical Name CAS # CA MA MN NJ PA RI Titanium Dioxide 13463-67-7 No No Yes Yes Yes Yes Carbon Black 1333-86-4 Yes Yes Yes Yes Yes Yes Calcium Carbonate 1317-65-3 No Yes Yes No Yes Yes Poly [[6-[ 1,1,3,3- tetramethylbuty1])amino]- striazine- 2,4-diy1][2,2,6,6-tetramethy1- 4- piperidy1)imino]hexamethylen e[(2,2,6,6-tetrame 70624-18-9 No No No No No No SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: N/A DATE OF PREVIOUS SDS: September 2013 CHANGES SINCE PREVIOUS SDS: Headquarters Address Change. This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of GAF SDS # 2005 Page 7 of 7 this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 2086 SDS Date: August 2018 _________________________________________________________________________ Page 1 of 6 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: EverGuard® 6” TPO White Cover Tape MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800-424-9300 INFORMATION ONLY: 800-766-3411 PREPARED BY: Corporate EHS APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. ADDITIONAL HAZARD IDENTIFICATION INFORMATION: PRIMARY ROUTE OF EXPOSURE: Eye Contact SIGNS & SYMPTOMS OF EXPOSURE EYES: Can cause irritation, redness, tearing and blurred vision. SKIN: Not likely to occur. INGESTION: Not likely to occur. INHALATION: Not likely to occur. ACUTE HEALTH HAZARDS: See above. GAF SDS # 2086 Page 2 of 6 CHRONIC HEALTH HAZARDS: None known CARCINOGENICITY: None listed. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER Non-hazardous ingredients n/a 100 NE NE NE NE = Not Established SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Treat as a foreign object in the eye. Flush with large amounts of water, frequently flushing under the lids. Get medical attention if irritation persists. SKIN: Not likely to be needed. INHALATION: Not likely to be needed. INGESTION: Not likely to be needed. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: None known. SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Foam, water, dry chemical or carbon dioxide. HAZARDOUS COMBUSTION PRODUCTS: Carbon dioxide and carbon monoxide. RECOMMENDED FIRE FIGHTING PROCEDURES: Limit fire fighting to those trained to do so. Minimize breathing gases, vapor, fumes or decomposition products. Use supplied air breathing equipment for enclosed or confined spaces or as otherwise needed. UNUSUAL FIRE & EXPLOSION HAZARDS: None known. GAF SDS # 2086 Page 3 of 6 SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: Shovel or scoop into a sealable container for disposal. SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Do not store or handle at temperatures in excess of 130 °F. Store in a cool, dry area. OTHER PRECAUTIONS: None known. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Not needed under normal conditions. RESPIRATORY PROTECTION: Not needed under normal conditions. EYE PROTECTION: Safety glasses with side shields are recommended. SKIN PROTECTION: Not needed under normal conditions. OTHER PROTECTIVE EQUIPMENT: Not needed under normal conditions. WORK HYGIENIC PRACTICES: Avoid prolonged or repeated contact with the skin. Product is readily removed from the skin with waterless hand cleaners followed by washing with soap and water. EXPOSURE GUIDELINES: N/A SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Tacky white solid with no odor. FLASH POINT: > 200 °F LOWER EXPLOSIVE LIMIT: No data METHOD USED: Estimate based on the flash point of the most volatile component. UPPER EXPLOSIVE LIMIT: No data GAF SDS # 2086 Page 4 of 6 EVAPORATION RATE: No data BOILING POINT: No data pH (undiluted product): No data MELTING POINT: No data SOLUBILITY IN WATER: Insoluble SPECIFIC GRAVITY: 0.97 VAPOR DENSITY: No data PERCENT VOLATILE: 0.7% Maximum VAPOR PRESSURE: No data MOLECULAR WEIGHT: No data VOC WITH WATER (LBS/GAL): No data WITHOUT WATER (LBS/GAL): No data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE CONDITIONS TO AVOID (STABILITY): Exposure to temperatures in excess of 130 °F. INCOMPATIBILITY (MATERIAL TO AVOID): None known. HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: In the event of partial combustion, fumes, smoke, carbon dioxide and carbon monoxide. HAZARDOUS POLYMERIZATION: Will not occur. _________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. _________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: This product, as supplied, is not regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. Comply with state and local regulations for disposal. GAF SDS # 2086 Page 5 of 6 RCRA HAZARD CLASS: None SECTION 14: TRANSPORTATION INFORMATION U.S. DOT TRANSPORTATION PROPER SHIPPING NAME: This product is not classified as a hazardous material for transport. HAZARD CLASS: N/A ID NUMBER: N/A PACKING GROUP: N/A LABEL STATEMENT: N/A OTHER: N/A SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: This product and its components are listed on the TSCA 8(b) inventory. CERCLA: None SARA 311/312 HAZARD CATEGORIES: None 313 REPORTABLE INGREDIENTS: None CALIFORNIA PROPOSITION 65: None Other state regulations may apply. Check individual state requirements. The following components appear on one or more of the following state hazardous substances lists: Chemical Name CAS # CA MA MN NJ PA RI Non-hazardous ingredients N/A No No No No No No SECTION 16: OTHER INFORMATION GAF SDS # 2086 Page 6 of 6 ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: October 2013 CHANGES SINCE PREVIOUS SDS: Headquarters Address Change This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS #2207 SDS Date:June 2023 _________________________________________________________________________ SECTION 1:PRODUCT AND COMPANY INFORMATION PRODUCT NAME:CleanWeld Conditioner Low VOC Cleaner MANUFACTURER:GAF ADDRESS:1 Campus Drive,Parsippany,NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC):800-424-9300 INFORMATION ONLY:877-GAF-ROOF PREPARED BY:Corporate EHS SECTION 2:HAZARDS IDENTIFICATION NFPA and HMIS RATINGS: NFPA Hazard Rating HMIS Hazard Rating Health 2 Health 2 Flammable 3 Flammable 3 Reactive 0 Reactive 0 Special Hazards -Personal Protection X GHS LABEL ELEMENTS: GHS CLASSIFICATION: Flammable Liquid -Category 3 Eye Irritant -Category 2A Skin Irritant -Category 2 Target Organ (SE)-Category 3 Target Organ (RE)-Category 2 Acute Toxicity (inhalation)-Category 4 GHS PICTOGRAMS: Page 1 of 8 GAF SDS #2207 SIGNAL WORD:Danger HAZARD STATEMENTS: PRECAUTIONARY STATEMENTS: Flammable liquid and vapor. May cause damage to organs through prolonged or repeated exposure. May cause respiratory irritation. Causes skin irritation. Harmful if inhaled. Causes serious eye irritation. May cause damage to organs through prolonged or repeated exposure. (hearing organs) May cause drowsiness or dizziness. Keep away from heat/sparks/open flames/hot surfaces.-No smoking. Keep container tightly closed. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Do not breathe dust/fume/gas/mist/vapors/spray. Wash skin thoroughly after handling. Use only outdoors or in a well-ventilated area. Wear protective gloves/eye protection/face protection. Get medical advice/attention if you feel unwell. Do NOT induce vomiting. If on skin (or hair):Take off immediately all contaminated clothing.Rinse skin with water/shower. In case of fire:Use carbon dioxide (CO2),foam,dry extinguishing powder to extinguish. Dispose of contents/container to a licensed hazardous-waste disposal contractor or collection site except for empty clean containers which can be disposed of as non-hazardous waste. Get medical attention if you feel unwell.IF exposed or concerned:Get medical attention. IF INHALED:Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or physician if you feel unwell. IF SWALLOWED:Immediately call a POISON CENTER or physician.Do NOT induce vomiting. IF ON SKIN (or hair):Take off immediately all contaminated clothing.Rinse skin with water or shower.IF ON SKIN:Wash with plenty of soap and water.Take off contaminated clothing and wash it before reuse.If skin irritation occurs:Get medical attention. IF IN EYES:Rinse cautiously with water for several minutes.Remove contact lenses,if present and easy to do.Continue rinsing.If eye irritation persists:Get medical attention. ADDITIONAL HAZARD IDENTIFICATION INFORMATION: PRIMARY ROUTE OF EXPOSURE:Eye contact,Skin contact,Inhalation SIGNS &SYMPTOMS OF EXPOSURE EYES:This material causes serious eye irritation.Contact with the liquid or exposure to mist or vapor may cause stinging,redness and swelling. Page 2 of 8 GAF SDS #2207 SKIN:This material causes mild skin irritation. INGESTION:Harmful if swallowed. INHALATION:High concentrations of vapor or mist may cause irritation of the nose and throat and signs of nervous system depression.Can cause headaches, drowsiness,dizziness,and loss of coordination. ACUTE HEALTH HAZARDS:See above. CHRONIC HEALTH HAZARDS:None known. CARCINOGENICITY:Not applicable. SECTION 3:COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS #%(BY WT)OSHA ACGIH OTHER 4-chlorobenzotrifluoride (PCBTF) 98-56-6 55 –60 NE NE NE Acetone 67-64-1 25 –30 TWA:750 ppm STEL:1000 ppm TWA:250 ppm STEL:500 ppm REL:TWA:250 ppm Xylene 1330-20-7 1 –5 100 ppm 100 ppm 125 ppm STEL REL:100 ppm 125 ppm STEL Balance of other ingredients are non-hazardous or less than 1%in concentration (or 0.1%for carcinogens, reproductive toxins,or respiratory sensitizers). NE =Not Established SECTION 4:FIRST AID MEASURES FIRST AID PROCEDURES EYES:Flush eyes immediately with water for 15 minutes.Remove contact lenses,if present and easy to do.Continue rinsing.Call a physician. SKIN:Remove contaminated clothes.Wash exposed areas with soap and water.If redness or swelling develops,seek medical assistance.Wash clothing separately before reuse.Destroy or thoroughly clean contaminated shoes. INHALATION:Remove to fresh air.If breathing has stopped,give artificial respiration. Call a physician. INGESTION:Rinse mouth thoroughly.Do not induce vomiting without advice from poison control center.Do not give mouth-to-mouth resuscitation.If vomiting occurs,keep head low so that stomach content does not get into the lungs.Never give anything by mouth to a victim who is Page 3 of 8 GAF SDS #2207 unconscious or is having convulsions.Get medical attention immediately. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: Symptoms may be delayed. SECTION 5:FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA:Water spray,water fog,CO2,dry chemical powder,sand and foam. HAZARDOUS COMBUSTION PRODUCTS:Carbon dioxide,carbon monoxide,chlorine compounds, fluoride compounds and hydrocarbons. RECOMMENDED FIRE FIGHTING PROCEDURES: Self contained breathing apparatus recommended.Use water spray to cool unopened containers. UNUSUAL FIRE &EXPLOSION HAZARDS: Material is flammable and may be ignited by flames,sparks, heat or other sources of ignition.Do not use a solid water stream as it may scatter and spread fire.Vapor may cause flash fire.Vapors can flow along surfaces to distant ignition source and flash back.Sensitive to static discharge.Heat may build pressure,rupturing closed containers,spreading fire and increasing risk of burns and injuries. SECTION 6:ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES:Eliminate all ignition sources (no smoking,flares,sparks or flames in the immediate area).Extinguish all flames in the vicinity.Dam up area to prevent spreading of material.Use a non-combustible material like vermiculite,sand or earth to soak up the product and place into a container for later disposal.Cover with plastic sheet to prevent spreading.Collect spillage.Prevent product from entering drains.Do not allow material to contaminate groundwater system. SECTION 7:HANDLING AND STORAGE HANDLING AND STORAGE:Store in a well ventilated area 50 –80oF.Ensure good ventilation of the work area.Wash hands and other exposed areas with mild soap and water before eating,drinking or smoking and when leaving work.Provide good ventilation in process area to prevent formation of vapour.Obtain special instructions before use.Keep away from heat,hot surfaces, sparks,open flames and other ignition sources.No smoking. Ground/bond container and receiving equipment.Use only non-sparking tools.Take precautionary measures against static discharge. OTHER PRECAUTIONS:The container is hazardous when empty.Partially full or emptied container may contain explosive vapors.Do not cut,weld,or solder on/or near the container.Do not reuse “empty”container without commercial cleaning or reconditioning Page 4 of 8 GAF SDS #2207 Do not eat,drink or smoke when using this product.Wash hands and other exposed areas with soap and water before eating, drinking or smoking and when leaving work. SECTION 8:EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Provide sufficient mechanical (general and/or local exhaust) ventilation to maintain exposure below exposure limits. RESPIRATORY PROTECTION:If exposure limits are exceeded or irritation is experienced, approved respiratory protection should be worn. EYE PROTECTION:Safety goggles or safety glasses with side shields. SKIN PROTECTION:Wear appropriate impermeable gloves and protective clothing as necessary to prevent skin contact. OTHER PROTECTIVE EQUIPMENT:None. WORK HYGIENIC PRACTICES:Wash exposed skin prior to eating,drinking,or smoking and at the end of each shift. SECTION 9:PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE &ODOR:Clear liquid with a mild odor. FLASH POINT:70o F LOWER EXPLOSIVE LIMIT:1% METHOD USED:TCC UPPER EXPLOSIVE LIMIT:10.5% EVAPORATION RATE:0.90 BOILING POINT:>131o F pH (undiluted product):No data MELTING POINT:No data SOLUBILITY IN WATER:No data SPECIFIC GRAVITY:0.79 VAPOR DENSITY:No data PERCENT VOLATILE:No data VAPOR PRESSURE:6.24 MOLECULAR WEIGHT:No data VOC (g/L):50 SECTION 10:STABILITY AND REACTIVITY THERMAL STABILITY:STABLE X UNSTABLE ☐ CONDITIONS TO AVOID:Heat,flames and sparks.Ignition sources.Contact with incompatible materials.Do not pressurize,cut,weld,braze, solder,drill,grind or expose empty containers to heat,flame, sparks,static electricity,or other sources of ignition;they may explode and cause injury or death. Page 5 of 8 GAF SDS #2207 INCOMPATIBILITY (MATERIAL TO AVOID): Strong oxidizing agents,acids and bases. HAZARDOUS DECOMPOSITION OR BY-PRODUCTS: Carbon Monoxide,carbon dioxide,chlorine compounds, fluoride compounds,hydrocarbons. HAZARDOUS POLYMERIZATION:Will not occur. _________________________________________________________________________________________ SECTION 11:TOXICOLOGICAL INFORMATION Symptoms/injuries after inhalation : May cause drowsiness or dizziness.Nausea.Headache. Symptoms/injuries after skin contact : May cause irritation to skin. Symptoms/injuries after eye contact : Vapors may cause painful eye irritation. Symptoms/injuries after ingestion :May be harmful if swallowed and enters airways.May cause gastric irritation. May cause stomach cramps and vomiting. Teratogenicity:No known significant effects or critical hazards. Germ cell mutagenicity:No known significant effects or critical hazards. Carcinogenicity:Not applicable. Specific target organ toxicity (repeated exposure):Causes damage to organs (central nervous system,hearing organs)through prolonged or repeated exposure (Dermal,Inhalation). Xylene LC50 Inhalation Vapor Rat 5000 ppm 4 hours LC50 Inhalation Vapor Rat 6700 ppm 4 hours LD50 Oral Mouse 2119 mg/kg LD50 Oral Rat 4300 mg/kg LD50 Oral Rat 4300 mg/kg Acetone LD50 Oral Rat 5800 mg/kg LC50 Inhalation Rat 76 mg/l,4 h LD50 Dermal Rabbit >15800 mg/kg PCBTF LD50 Oral Rat 13000 mg/kg LD50 Dermal Rabbit >2000 mg/kg LC50 Inhalation Rat 33 mg/l SECTION 12:ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: Xylene Acute EC50 90 mg/l Fresh water Crustaceans -Cypris subglobosa 48 hours Acute LC50 8.5 ppm Marine water Crustaceans -Palaemonetes pugio 48 hours Acute LC50 8500 μg/l Marine water Crustaceans -Palaemonetes pugio 48 hours Acute LC50 15700 μg/l Fresh water Fish -Lepomis macrochirus 96 hours Acute LC50 19000 μg/l Fresh water Fish -Lepomis macrochirus 96 hours Page 6 of 8 GAF SDS #2207 Acute LC50 13400 μg/l Fresh water Fish -Pimephales promelas 96 hours Effect on ozone layer :Not considered harmful to the ozone layer. _______________________________________________________________________________________ SECTION 13:DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD:Dispose in accordance with all applicable local,state and Federal regulations.Do not allow this material to drain into sewers/water supplies.Do not contaminate ponds,waterways or ditches with chemical or used container. SECTION 14:TRANSPORTATION INFORMATION DOT UN number UN1993 UN proper shipping name Flammable liquid n.o.s.(4-Chlorobenzotrifluoride,acetone) Hazard Class 3 Packing group II IATA UN number UN1993 UN proper shipping name Flammable liquid n.o.s.(4-Chlorobenzotrifluoride,acetone) Hazard Air Class 3 Packing group II IMDG UN Number UN1993 UN proper shipping name Flammable liquid n.o.s.(4-Chlorobenzotrifluoride,acetone) Hazard Class 3 Packing group II EmS-No F-E,S-E SECTION 15:REGULATORY INFORMATION U.S.FEDERAL REGULATIONS TSCA:This product and its components are listed on the TSCA 8(b) inventory. CERCLA:Not applicable. SARA 311/312 HAZARD CATEGORIES:Acute Health Hazard,Chronic Health Hazard,Fire Hazard 313 REPORTABLE INGREDIENTS:Not applicable. CALIFORNIA PROPOSITION 65:This product can expose you to Parachlorobenzo-trifluoride (PCBTF),which is known to the State of California to cause cancer. SECTION 16:OTHER INFORMATION ADDITIONAL COMMENTS:None Page 7 of 8 GAF SDS #2207 DATE OF PREVIOUS SDS:May 2017 CHANGES SINCE PREVIOUS SDS:Updated GHS information. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process.Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled.However,no representation, warranty or guarantee,expressed or implied,is made as to its accuracy,reliability,or completeness.It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use.We do not accept liability for any loss or damage that may occur from the use of this information.Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. Page 8 of 8 47.0.11 · Classification of the substance or mixture GHS02 Flame Flam. Liq. 2 H225 Highly flammable liquid and vapor. GHS08 Health hazard Asp. Tox. 1 H304 May be fatal if swallowed and enters airways. GHS07 Eye Irrit. 2A H319 Causes serious eye irritation. STOT SE 3 H336 May cause drowsiness or dizziness. Label elements GHS label elements The product is classified and labeled according to the Globally Harmonized System (GHS). Hazard pictograms GHS02 GHS07 GHS08 Signal word Danger Hazard statements Highly flammable liquid and vapor. Causes serious eye irritation. (Contd. on page 2) USA SDS 4192 Safety Data Sheet acc. to OSHA HCS Revision Number 4 Page 1/9 Issue Date November 2023 * * SDS333S Product identifier Trade name: Low VOC Seam Cleaner Relevant identified uses of the substance or mixture. Solvent Details of the supplier of the safety data sheet Manufacturer/Supplier: GAF 1 Campus Drive Parsippany, NJ 07054 Information Phone Number: 877-GAF-ROOF Emergency telephone number: ChemTrec: Day or Night within USA and Canada: 1-800-424-9300. Outside USA and Canada: +1 703-527-3887 (collect calls accepted) 1 Identification 2 Hazard(s) identification Page 2/9 Safety Data Sheet acc. to OSHA HCS Revision Number 4 SDS 4192 Issue Date November 2023 Trade name: Low VOC Seam Cleaner 47.0.11 Chemical characterization: Mixtures Description: Mixture USA * · Hazardous components: 67-64-1 acetone 50-100% 64742-47-8 Distillates (petroleum), hydrotreated light 25-50% (Contd. on page 3) (Contd. of page 1) May cause drowsiness or dizziness. May be fatal if swallowed and enters airways. Precautionary statements Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapors/spray Wash thoroughly after handling. Use only outdoors or in a well-ventilated area. Wear protective gloves/protective clothing/eye protection/face protection. If swallowed: Immediately call a poison center/doctor. Do NOT induce vomiting. If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. IF INHALED: Remove person to fresh air and keep comfortable for breathing. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Call a poison center/doctor if you feel unwell. If eye irritation persists: Get medical advice/attention. In case of fire: Use for extinction: CO2, powder or water spray. Store in a well-ventilated place. Keep container tightly closed. Store in a well-ventilated place. Keep cool. Store locked up. Dispose of contents/container in accordance with local/regional/national/international regulations. Classification system: NFPA ratings (scale 0 - 4) 2 0 Health = 2 Fire = 3 Reactivity = 0 · HMIS-ratings (scale 0 - 4) HEALTH FIRE PHYSICAL HAZARD 0 Health = 2 Fire = 3 Physical Hazard = 0 Other hazards Results of PBT and vPvB assessment PBT: Not applicable. vPvB: Not applicable. 3 Composition/information on ingredients Page 3/9 Safety Data Sheet acc. to OSHA HCS Revision Number 4 SDS 4192 Issue Date November 2023 Trade name: Low VOC Seam Cleaner 47.0.11 Description of first aid measures After inhalation: Supply fresh air or oxygen; call for doctor. In case of unconsciousness place patient stably in side position for transportation. After skin contact: Immediately wash with water and soap and rinse thoroughly. After eye contact: Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. After swallowing: Do not induce vomiting; immediately call for medical help. Information for doctor: Most important symptoms and effects, both acute and delayed No further relevant information available. Indication of any immediate medical attention and special treatment needed No further relevant information available. Extinguishing media Suitable extinguishing agents: CO2, extinguishing powder or water spray. Fight larger fires with water spray. Use fire fighting measures that suit the environment. Special hazards arising from the substance or mixture No further relevant information available. Advice for firefighters Firefighters use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Protective equipment: Protective clothing and respiratory protective device. Personal precautions, protective equipment and emergency procedures Ensure adequate ventilation Wear protective equipment. Keep unprotected persons away. Environmental precautions: Do not allow to enter sewers/ surface or ground water. Methods and material for containment and cleaning up: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dispose of contaminated material as waste in accordance with federal state and local regulations. Ensure adequate ventilation. Reference to other sections See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information. Protective Action Criteria for Chemicals USA * * * (Contd. of page 2) 4 First-aid measures 5 Fire-fighting measures 6 Accidental release measures · PAC-1: 67-64-1 acetone 200 ppm · PAC-2: 67-64-1 acetone 3200* ppm · PAC-3: 67-64-1 acetone 5700* ppm (Contd. on page 4) Page 4/9 Safety Data Sheet acc. to OSHA HCS Revision Number 4 SDS 4192 Issue Date November 2023 Trade name: Low VOC Seam Cleaner (Contd. on page 4) USA 47.0.11 Additional information about design of technical systems: No further data; see item 7. Control parameters Components with limit values that require monitoring at the workplace: The following constituent is the only constituent of the product which has a PEL, TLV or other recommended exposure limit. At this time, the remaining constituent has no known exposure limits. Additional information: The lists that were valid during the creation were used as basis. Exposure controls Personal protective equipment (see listings below) General protective and hygienic measures: Keep away from foodstuffs, beverages and feed. Immediately remove all soiled and contaminated clothing. Wash hands before breaks and at the end of work. Avoid contact with the eyes. Avoid contact with the eyes and skin. (Contd. of page 3) * * 67-64-1 acetone PEL REL TLV Long-term value: 2400 mg/m³, 1000 ppm Long-term value: 590 mg/m³, 250 ppm Short-term value: 1187 mg/m³, 500 ppm Long-term value: 594 mg/m³, 250 ppm BEI · Ingredients with biological limit values: 67-64-1 acetone BEI 50 mg/L Medium: urine Time: end of shift Parameter: Acetone (nonspecific) Handling: Precautions for safe handling Open and handle receptacle with care. Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols. Information about protection against explosions and fires: Keep ignition sources away - Do not smoke. Keep container closed when not in use. Protect against electrostatic charges. Conditions for safe storage, including any incompatibilities Storage: Requirements to be met by storerooms and receptacles: Store in a cool location away from direct heat. Information about storage in one common storage facility: Store away from oxidizing agents. Further information about storage conditions: Keep receptacle tightly sealed. Specific end use(s) No further relevant information available. 7 Handling and storage 8 Exposure controls/personal protection Page 5/9 Safety Data Sheet acc. to OSHA HCS (Contd. on page 5) USA 47.0.11 SDS 4192 Revision Number 4 Issue Date November 2023 * · Information on basic physical and chemical properties · General Information · Appearance: Form: Fluid Color: Clear · Odor: Characteristic · Odor threshold: Not determined. · pH-value: Not applicable. · Change in condition Melting point: Boiling point: Undetermined. 55 °C (131 °F) · Flash point: -19 °C (-2.2 °F) · Flammability (solid, gaseous): Not applicable. · Ignition temperature: 210 °C (410 °F) · Decomposition temperature: Not determined. · Auto igniting: Product is not selfigniting. · Danger of explosion: Product is not explosive. However, formation of explosive air/vapor mixtures are possible. Trade name: Low VOC Seam Cleaner 9 Physical and chemical properties (Contd. of page 4) Breathing equipment: Use approved respiratory protection equipment when airborne exposure is excessive. Consult the respirator manufacturer to determine the appropriate type of equipment for a given application. Observe respirator use limitations specified by the manufacturer. Protection of hands: Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Material of gloves Nitrile rubber, NBR The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. Eye protection: Safety glasses with side shields. Tightly sealed goggles Face shield over protective glasses or goggles. Body protection: Protective work clothing Page 6/9 Safety Data Sheet acc. to OSHA HCS 47.0.11 (Contd. of page 5) SDS 4192 Revision Number 4 Issue Date November 2023 · Flammable limits: Lower: Upper: 0.5 Vol % 13.0 Vol % · Vapor pressure at 20 °C (68 °F): 233 hPa (174.8 mm Hg) · Specific gravity at 20 °C (68 °F): · Relative density · Vapor density · Evaporation rate 0.79 g/cm³ (6.59255 lbs/gal) Not determined. Not determined. Not determined. · Solubility in / Miscibility with Water: Not Soluble · Partition coefficient (n-octanol/water): Not determined. · Viscosity: Dynamic: Kinematic: Not determined. Not determined. · Solvent content: Organic solvents: Not available Solids content: · Other information Not available. VOC: 224 G/L (2 LBS/GAL) WEIGHT PER GALLON: 6.57 SCAQMD: 244 G/L * * · Information on toxicological effects · Acute toxicity: · LD/LC50 values that are relevant for classification: 67-64-1 acetone Oral LD50 5,800 mg/kg (rat) Dermal LD50 20,000 mg/kg (rabbit) · Primary irritant effect: · on the skin: May irritate the skin. · on the eye: Causes serious eye irritation. Vapors may be irritating to the eyes. · Sensitization: No sensitizing effects known. (Contd. on page 7) USA Trade name: Low VOC Seam Cleaner Reactivity No further relevant information available. Chemical stability Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications. Possibility of hazardous reactions No dangerous reactions known. Conditions to avoid Heat, flames, sparks. Incompatible materials: Reacts with oxidizing agents. Hazardous decomposition products: Carbon monoxide and carbon dioxide 10 Stability and reactivity 11 Toxicological information Page 7/9 Safety Data Sheet acc. to OSHA HCS Revision Number 4 SDS 4192 Issue Date November 2023 Trade name: Low VOC Seam Cleaner (Contd. of page 6) 47.0.11 Additional toxicological information: The product shows the following dangers according to internally approved calculation methods for preparations: Irritant Carcinogenic categories (Contd. on page 8) USA · IARC (International Agency for Research on Cancer) None of the ingredients is listed. · NTP (National Toxicology Program) None of the ingredients is listed. · OSHA-Ca (Occupational Safety & Health Administration) None of the ingredients is listed. * * * · UN-Number · DOT, IMDG, IATA UN1993 · UN proper shipping name · DOT, IMDG, IATA FLAMMABLE LIQUID, N.O.S. (ACETONE) · Transport hazard class(es) · DOT · Class 3 Flammable liquids Toxicity Aquatic toxicity: No further relevant information available. Persistence and degradability No further relevant information available. Behavior in environmental systems: Bioaccumulative potential No further relevant information available. Mobility in soil No further relevant information available. Additional ecological information: General notes: At present there are no ecotoxicological assessments. Results of PBT and vPvB assessment PBT: Not applicable. vPvB: Not applicable. Other adverse effects No further relevant information available. Waste treatment methods Recommendation: Must be specially treated adhering to official regulations. Uncleaned packagings: Recommendation: Disposal must be made according to official regulations. 12 Ecological information 13 Disposal considerations 14 Transport information Page 8/9 Safety Data Sheet acc. to OSHA HCS Revision Number 4 SDS 4192 Issue Date November 2023 Trade name: Low VOC Seam Cleaner (Contd. of page 7) 47.0.11 Safety, health and environmental regulations/legislation specific for the substance or mixture Sara · Proposition 65 · (DSL) Canada Dosmestic Substance List All components of this product are on the DSL(Canada Domestic Substance list) or are exempt from DSL requirements. (Contd. on page 9) USA · Label 3 · IMDG, IATA · Class 3 Flammable liquids · Label 3 · Packing group · DOT, IMDG, IATA II · Environmental hazards: Not applicable. · Special precautions for user Warning: Flammable liquids · Danger code (Kemler): 33 · EMS Number: F-E,S-E · Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code Not applicable. · UN "Model Regulation": UN1993, FLAMMABLE LIQUID, N.O.S. (ACETONE), 3, II * · Section 355 (extremely hazardous substances): None of the ingredients is listed. · Section 313 (Specific toxic chemical listings): None of the ingredients is listed. · TSCA (Toxic Substances Control Act): All components of this product are on the TSCA Inventory or are exempt from TSCA Inventory requirements. · Chemicals known to cause cancer: None of the ingredients is listed. · Chemicals known to cause reproductive toxicity for females: None of the ingredients is listed. · Chemicals known to cause reproductive toxicity for males: None of the ingredients is listed. · Chemicals known to cause developmental toxicity: None of the ingredients is listed. · New Jersey Right-to-Know List: 67-64-1 acetone 15 Regulatory information Page 9/9 Safety Data Sheet acc. to OSHA HCS 47.0.11 (Contd. of page 8) · Cancerogenity categories National regulations: Water hazard class: Water hazard class 3 (Self-assessment): extremely hazardous for water. Chemical safety assessment: A Chemical Safety Assessment has not been carried out. SDS 4192 Revision Number 4 Issue Date November 2023 · New Jersey Special Hazardous Substance List: 67-64-1 acetone F3 · Pennsylvania Right-to-Know List: 67-64-1 acetone · Pennsylvania Special Hazardous Substance List: 67-64-1 acetone E · EPA (Environmental Protection Agency) 67-64-1 acetone I · TLV (Threshold Limit Value established by ACGIH) 67-64-1 acetone A4 · MAK (German Maximum Workplace Concentration) None of the ingredients is listed. · NIOSH-Ca (National Institute for Occupational Safety and Health) None of the ingredients is listed. * Trade name: Low VOC Seam Cleaner This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. USA 16 Other information Page 10/10 Safety Data Sheet acc. to OSHA HCS 47.0.11 GAF Safety Data Sheet SDS # 2123 SDS Date: December 2022 _________________________________________________________________________ Page 1 of 8 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAME: Low VOC TPO Primer MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24 HOUR EMERGENCY PHONE: (CHEMTREC) 800 – 424–9300 INFORMATION ONLY: 877–GAF–ROOF APPROVED BY: Corporate EHS SECTION 2: HAZARD IDENTIFICATION NFPA and HMIS RATINGS: NFPA Hazard Rating HMIS Hazard Rating Health 2 Health 2 Flammable 3 Flammable 3 Reactive 0 Reactive 0 Special Hazards - Personal Protection X GHS LABEL ELEMENTS: GHS CLASSIFICATION: Flammable Liquid - Category 2 Eye Irritant - Category 2A Skin Irritant - Category 2 Target Organ (SE) - Category 2 Aspiration Toxicity - Category 1 Reproductive Toxicity - Category 2 GAF SDS # 2123 Page 2 of 8 GHS PICTOGRAMS: SIGNAL WORD: Danger HAZARD STATEMENTS: PRECAUTIONARY STATEMENTS: Highly flammable liquid and vapor May cause damage to organs through prolonged or repeated ex Causes skin irritation Causes serious eye irritation Suspected of damaging fertility or the unborn child May be fatal if swallowed and enters airways Obtain, read and follow all safety instructions before use. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Keep container tightly closed. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Do not breathe dust/fume/gas/mist/vapors/spray. Wash thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection. If swallowed: Immediately call a poison center/doctor. If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF exposed or concerned: Get medical advice/attention. Get medical advice/attention if you feel unwell. Specific treatment (see on this label). Do NOT induce vomiting. If skin irritation occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention. GAF SDS # 2123 Page 3 of 8 SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER 4-Chlorobenzo- trifluoride (PCBTF) 98-56-6 50 - 100 NE NE NE Toluene 108-88-3 10 – 25 200 ppm 300 ppm – ceiling 20 ppm REL: 100 ppm 150 ppm – STEL Isobutylene Copolymer NA <2.5 NE NE NE NE = Not Established SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Flush with large amounts of water, frequently flushing under the lids. Seek medical attention. SKIN: Wash with soap and water. Get medical attention if irritation persists. INHALATION: Remove affected person to fresh air, give oxygen or artificial respiration as necessary to assist breathing. Get medical attention. INGESTION: Rinse out mouth with water. Drink 1 - 2 glasses of water but DO NOT induce vomiting. Do not give liquids to a drowsy, convulsing or unconscious person. If vomiting occurs spontaneously, keep head below hips to prevent aspiration. Call a doctor immediately. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: No further relevant information available. SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Foam, dry chemical or carbon dioxide. Water may be ineffective, but water should be used to keep fire exposed containers cool. HAZARDOUS COMBUSTION PRODUCTS: Carbon dioxide, carbon monoxide and various hydrocarbons RECOMMENDED FIRE FIGHTING PROCEDURES: Wear impermeable protective clothing and self-contained breathing apparatus. Toxic fumes or vapors may be produced. GAF SDS # 2123 Page 4 of 8 Shut down motors and pumps to prevent spreading of fire. UNUSUAL FIRE & EXPLOSION HAZARDS: This product is volatile and gives off vapors. Either the liquid or vapor may settle in low areas or travel along the ground or surface to ignition sources where they may ignite or explode. Overheated drums will explode. High vapor concentrations have an anesthetic effect. SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: Eliminate all ignition sources. Control the source of the spill if it is safe to do so. Ventilate enclosed areas to prevent vapor accumulation. Restrict access by unauthorized personnel. Absorb spilled product with vermiculite or other absorbent material. Shovel or scoop into a sealable container for disposal. SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Do not store or handle near an ignition source. Keep containers closed. Effectively ground the product transfer system to prevent fire or explosion from static discharge. Empty containers may contain residual product. Do not reuse containers unless properly reconditioned. Do not smoke. OTHER PRECAUTIONS: None. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: General exhaust as needed to keep work environment below exposure limits if engineering or administrative controls are not adequate. RESPIRATORY PROTECTION: For large spills or entry into enclosed small spaces with inadequate ventilation, a pressure demand, self-contained breathing apparatus is recommended. If engineering or administrative controls are not adequate to maintain work environment below solvent TLV recommended levels, an appropriate respirator should be used in conjunction with a respirator use and fit training program. EYE PROTECTION: Safety glasses with side shields or goggles. SKIN PROTECTION: Chemical resistant gloves. To prevent repeated or prolonged skin contact, wear impervious clothing and boots if contact is likely. OTHER PROTECTIVE EQUIPMENT: Not applicable. GAF SDS # 2123 Page 5 of 8 WORK HYGIENIC PRACTICES: Minimize breathing vapor. Avoid prolonged or repeated contact with the skin. Remove contaminated clothing and launder before reuse. Cleanse skin thoroughly after contact, before work breaks and meals, and at the end of the work day. Product is readily removed from the skin with waterless hand cleaners followed by washing thoroughly with soap and water. Eye wash stations should be available where product may come in contact with the eyes. EXPOSURE GUIDELINES: Not applicable. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Translucent liquid with aromatic odor. FLASH POINT: 45°F LOWER EXPLOSIVE LIMIT: 1.2% METHOD USED: No data UPPER EXPLOSIVE LIMIT: 7.0% EVAPORATION RATE: No data BOILING POINT: 111°C pH (undiluted product): No data MELTING POINT: No data SOLUBILITY IN WATER: Insoluble SPECIFIC GRAVITY: 1.15 – 1.25 VAPOR DENSITY: > 1 PERCENT VOLATILE: 90% VAPOR PRESSURE: 22 mm Hg @ 68°F MOLECULAR WEIGHT: No data VOC WITH WATER (g/L): 250 g/l WITHOUT WATER (g/L): No data SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE X UNSTABLE CONDITIONS TO AVOID (STABILITY): Avoid flames, sparks, or other sources of ignition. INCOMPATIBILITY (MATERIAL TO AVOID): Avoid contact with acids, alkaline and strong oxidizing agents. HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: Carbon dioxide, carbon monoxide, fluorine gas, chlorine gas, acrid smoke and irritating fumes. HAZARDOUS POLYMERIZATION: Will not occur. GAF SDS # 2123 Page 6 of 8 _________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION 108-88-3 Toluene Oral LD50 5,000 mg/kg (rat) Dermal LD50 12,124 mg/kg (rabbit) Inhalative LC50/4 h 5,320 mg/l (mouse) Primary irritant effect: on the skin: Skin irritant. on the eye: Irritating effect. Vapors may be irritating to the eyes. Sensitization: No sensitizing effects known. Additional toxicological information: The product shows the following dangers according to internally approved calculation methods for preparations: Irritant SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. _________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: Follow all federal, state and local regulations. SECTION 14: TRANSPORTATION INFORMATION U.S. DOT TRANSPORTATION PROPER SHIPPING NAME: Adhesives HAZARD CLASS: 3 ID NUMBER: UN1133 PACKING GROUP: II LABEL STATEMENT: N/A · Transport hazard class(es) · DOT GAF SDS # 2123 Page 7 of 8 · Class 3 Flammable liquids IATA PROPER SHIPPING NAME: Adhesive HAZARD CLASS: 3 ID NUMBER: UN1133 PACKING GROUP: II LABEL STATEMENT: N/A OTHER: N/A IMDG PROPER SHIPPING NAME: Adhesive HAZARD CLASS: 3 ID NUMBER: UN1133 PACKING GROUP: II LABEL STATEMENT: N/A OTHER: EMS: FE,SE SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: This product and its components are listed on the TSCA 8(b) GAF SDS # 2123 Page 8 of 8 inventory. CERCLA: CERCLA Hazardous Substances (40 CFR 302) Reportable Quantity – Components Toluene: 108-88-3, 1000 lbs SARA: 311/312 HAZARD CATEGORIES: Acute Health Hazard, Chronic Health Hazard, Fire Hazard 313 REPORTABLE INGREDIENTS: Toluene: 108-88-3 CALIFORNIA PROPOSITION 65: This product contains toluene, a chemical known to the state of California to cause birth defects or other reproductive harm and PCBTF, a chemical known to the state of California to cause cancer. Other state regulations may apply. Check individual state requirements. The following components appear on one or more of the following state hazardous substances lists: Chemical Name CAS # CA MA MN NJ PA RI Parachlorobenzotrifluoride 98-56-6 Yes Yes Yes Yes Yes Yes Toluene 108-88-3 Yes Yes Yes Yes Yes Yes SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: March 2020. CHANGES SINCE PREVIOUS SDS: Name change. This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Corporation Safety Data Sheet SDS # 4054 SDS Date: February 2023 PRODUCT NAME:EverGuard One-Part Pourable Sealant DESCRIPTION:One-Part Pourable Sealer, Moisture cure sealant MANUFACTURER:GAF ADDRESS:1 Campus Drive, Parsippany NJ 07054 TELEPHONE:877-GAF-ROOF CHEMTREC PHONE:1-800-424-9300 PREPARED BY:Corporate EHS Classification of the Substance or mixture: OSHA Regulatory Status This chemical is not considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) Label Elements Emergency Overview: The product contains no substances which at their given concentration, are considered to be hazardous to health Physical state:liquid Odor:Odorless GHS Pictogram Signal Word WARNING Hazard Statements H315: Causes skin irritation. H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. GAF SDS # 4054 Precautionary Statements: Prevention P273: Avoid release to the environment. P280: Wear protective gloves/ protective clothing / eye protection/ face protection. Precautionary Statements: Response P302 + P352 IF ON SKIN: Wash with plenty of water. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Disposal P501: Dispose of contents/ container to an approved waste disposal plant. Other Hazards None known. Ingredient Name:Product Identifier % by weight Silyl Terminated Polyether CAS Number :75009-88-0 >99 Trade Secret Organic*Proprietary <0.1 *The specific chemical identity and/or exact (concentration) of this composition has been withheld as a trade secret Description of Necessary First Aid Measures: Eye Contact IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Call a physician. Skin Contact Wash off immediately with plenty of water for at least 15 minutes. Remove contaminated clothing and shoes. Consult a physician if necessary. Inhalation Move to fresh air in case of accidental inhalation of vapors. If breathing is irregular or stopped, administer artificial respiration. Administer oxygen if breathing is difficult. Call a physician. Ingestion If swallowed, call a poison control center or physician immediately. Most important symptoms and effects, both acute and delayed Symptoms No information available. Note to Physician:Treat symptomatically. Contact Poison treatment specialist immediately if large quantities have been ingested or inhaled. Suitable Extinguishing Media Water, CO2, Dry Chemical, Foam. Hazard Combustion products Thermal decomposition may produce toxic fumes of Carbon Monoxide, Carbon dioxide, Sulfur oxides and Hydrogen sulfide. Advice for Fire-Fighters Wear self-contained breathing apparatus for firefighting if necessary. Flash Point (°C)Not available. Personal Precautions Wear personal protective clothing and equipment, see Section 8. Avoid eye, skin and clothing contact. Protective Equipment Use personal protective equipment. Ensure adequate ventilation. Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. GAF SDS # 4054 Methods for cleaning up Collect spill with absorbent material such as cardboard, allow to cure and place into a container approved for waste disposal. Regulatory Requirements:Follow applicable OSHA regulations (29 CFR 1910.120). Precautions for safe handling Use personal protection, see Section 8. Avoid eye, skin and clothing contact Prevention of Fires and Explosions: Product is not considered flammable under normal conditions, and product is not considered explosive Storage Requirements:Store in a cool dry area (this product polymerizes when in contact with moisture.) Appropriate Engineering Controls Handle in accordance with good industrial hygiene and safety practices. Wash hands before breaks and at the end of workday. Eye/Face Protection Wear safety glasses or goggles to avoid eye contact. Skin Protection Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching gloves outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Wear appropriate work clothing. Wear protective shoes. Recommended material: protective skin cream Hand Protection Wear impervious gloves such as vinyl to minimize contact with skin. Control of Environmental Exposure Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. Physical state Water Solubility: Insoluble Appearance Paste Color White Odor Threshold Not available pH 6.0-8.0 Melting Point Not available Freezing Point Not available Initial Boiling Point Not available Flash Point 205-240 °C 401-464 °F Flash Point Method Based on FP of the most volatile component. Flammability (solid, gas)Not available Vapor Pressure <1 Lower Explosive Limit Not available Upper Explosive Limit Not available Vapor Density (air=1)>1 Relative Density 11.59 lbs./gal. Autoignition Temperature Not available GAF SDS # 4054 Chemical Stability Stable under normal conditions of use. Conditions to avoid None Known Incompatible materials None Known Hazardous decomposition products Thermal decomposition may produce toxic fumes of Carbon Monoxide (CO) and/or Carbon Dioxide (CO2). Amino Silane (Refer to sections 2 and 3) Oral: LD50 > 2,000 mg /kg. Remark: Very low order of toxicity. Skin Absorption: LD50 > 2,000 mg/kg. Remark: Very low order of toxicity. Inhalation: LC50 Not acutely Toxic. Skin Direct Contact Slight irritation Eye Direct Contact Severe irritation. Remark: Causes corneal injury Exposure Limits Not applicable. Sensitization No. Reproductive Toxicity No Mutagenicity No Teratogenicity No Synergistic Products None No known applicable information Waste Disposal Recommendations If this product as supplied becomes a waste, it does not meet the criteria of a hazardous waste as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. This product becomes a firm synthetic rubber when cured. Please allow to cure before disposal. Special shipping information None DOT Not regulated TDG Not regulated IATA Not regulated IMDG Not regulated ICAO (air)Not regulated International Inventories TSCA Complies DSL/NDSL Complies EINECS/ELINCS Polymer Exempt ENCS Complies IECSC Complies KECL Complies PICCS Does not comply AICS Complies Legend: GAF SDS # 4054 TSCA - United States Toxic Substances Control Act Section 8(b) Inventory DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List EINECS/ELINCS - European Inventory of Existing Chemical Substances/European List of Notified Chemical Substances ENCS - Japan Existing and New Chemical Substances IECSC - China Inventory of Existing Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances PICCS - Philippines Inventory of Chemicals and Chemical Substances AICS - Australian Inventory of Chemical Substances US Federal Regulations SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 SARA 311/312 Hazard Categories Acute health hazard No Chronic Health Hazard No Fire hazard No Sudden release of pressure hazard No Reactive Hazard No CWA (Clean Water Act) This product does not contain any substances regulated as pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42) CERCLA Trace Proprietary Organic Compound = 5000lbs (2270 kg) US State Regulations California Proposition 65 This product does not contain any chemicals known by the State of California to cause cancer. U.S. State Right-to-Know Regulations U.S. EPA Label Information EPA Pesticide Registration Number Not applicable NFPA Health hazards 1 Flammability 1 Instability 0 HMIS Health hazards 1 Flammability 1 Physical hazards 0 Personal protection X ADDITIONAL COMMENTS:None DATE OF PREVIOUS SDS:April 2021 CHANGES SINCE PREVIOUS SDS:Update to Section 1 GAF SDS # 4054 This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 4026 SDS Date: March 2023 SECTION 1: IDENTIFICATION Product Identifier Trade Name: EverGuard TPO Quick Spray Adhesive LV50 Hose and Gun CleanerProduct Form: Mixture Intended Use of the Product Use of the Substance/Mixture: No use is specified. Name, Address, and Telephone of the Responsible Party Company GAF 1 Campus Drive, Parsippany, NJ 07054 Information phone: 877-GAF-ROOF (USA) Emergency Telephone Number Emergency Number : CHEMTREC 1-800-424-9300 SECTION 2: HAZARDS IDENTIFICATION Classification of the Substance or Mixture Classification (GHS-US) Flam. Liq. 2 H225 Compressed gas H280 Skin Irrit. 2 H315 Eye Irrit. 2A H319 Asp Hzrd H304 STOT SE 3 H336 Full text of H-phrases: see section 16 Label Elements GHS-US Labeling Hazard Pictograms (GHS-US) : GHS02 GHS04 GHS07 Signal Word (GHS-US) : Danger Hazard Statements (GHS-US) : H225 - Highly flammable liquid and vapor. H280 - Contains gas under pressure; may explode if heated. H304 – May be fatal if swallowed or enters airway. H315 - Causes skin irritation. H319 - Causes serious eye irritation. H336 - May cause drowsiness or dizziness. Precautionary Statements (GHS-US) : P210 - Keep away from extremely high or low temperatures, ignition sources, and incompatible materials. - No smoking. P233 - Keep container tightly closed. P240 - Ground/bond container and receiving equipment. P241 - Use explosion-proof electrical, ventilating, and lighting equipment. P242 - Use only non-sparking tools. P243 - Take precautionary measures against static discharge. 1/9 SDS # 4026 2/9 P261 - Avoid breathing vapors, mist, or spray. P264 - Wash hands, forearms, and other exposed areas thoroughly after handling. P271 - Use only outdoors or in a well-ventilated area. P280 - Wear respiratory protection, protective clothing, protective gloves, eye protection. P303+P361+P353 - IF ON SKIN (OR HAIR): Take off immediately all contaminated clothing. Rinse skin with water/shower. P304+P340 - IF INHALED: Remove person to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P312 - Call a poison center or doctor if you feel unwell. P337+P313 - If eye irritation persists: Get medical advice/attention. P370+P378 - In case of fire: Use Water, alcohol resistant foam, carbon dioxide (CO2), extinguishing powder, sand to extinguish. P381 - Eliminate all ignition sources if safe to do so. P403+P233 - Store in a well-ventilated place. Keep container tightly closed. Other Hazards Exposure may aggravate those with pre-existing eye, skin, or respiratory conditions. Flammable vapors can accumulate in head space of closed systems. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS Mixture Name Product Identifier % (w/w) Methyl acetate (CAS No) 79-20-9 80 – 100 Heptane, branched, cyclic and linear (CAS No) 426260-76-6 1 - 5 n-Heptane (CAS No) 142-82-5 1 - 5 Nitrogen (CAS No) 7727-37-9 1 - 5 SECTION 4: FIRST AID MEASURES Description of First Aid Measures General: Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label if possible). Inhalation: Remove to fresh air and keep at rest in a position comfortable for breathing. Obtain medical attention if breathing difficulty persists. Skin Contact: Remove contaminated clothing. Gently wash with plenty of soap and water followed by rinsing with water for at least 15 minutes. Call a POISON CENTER or doctor/physician if you feel unwell. Wash contaminated clothing before reuse. Eye Contact: Rinse cautiously with water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Obtain medical attention. Ingestion: Do NOT induce vomiting. Rinse mouth. Immediately call a POISON CENTER or doctor/physician. Most Important Symptoms and Effects Both Acute and Delayed General: Causes skin irritation. May cause drowsiness or dizziness. Causes eye irritation. Inhalation: May cause drowsiness or dizziness. Skin Contact: Causes skin irritation. Redness, pain, swelling, itching, burning, dryness, and dermatitis. Eye Contact: Causes eye irritation. Symptoms may include: Redness, pain, swelling, itching, burning, tearing, and blurred vision. Ingestion: Ingestion is likely to be harmful or have adverse effects. Chronic Symptoms: Not available Indication of Any Immediate Medical Attention and Special Treatment Needed If you feel unwell, seek medical advice (show the label where possible). SECTION 5: FIRE-FIGHTING MEASURES Extinguishing Media Suitable Extinguishing Media: Water spray, fog, carbon dioxide (CO2), alcohol-resistant foam, dry chemical, or sand. Unsuitable Extinguishing Media: Do not use a heavy water stream. Use of heavy stream of water may spread fire. SDS # 4026 3/9 Special Hazards Arising From the Substance or Mixture Fire Hazard: Highly flammable liquid and vapor. Explosion Hazard: May form flammable/explosive vapor-air mixture. Reactivity: Vapors are heavier than air and may travel considerable distance to an ignition source and flash back to source of vapors. Reacts with (strong) oxidizers: (increased) risk of fire. Advice for Firefighters Precautionary Measures Fire: Exercise caution when fighting any chemical fire. Under fire conditions, hazardous fumes will be present. Firefighting Instructions: Use water spray or fog for cooling exposed containers. In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion. Do not allow run-off from firefighting to enter drains or water courses – may cause explosion hazard in drains and may reignite on surface water. Protection During Firefighting: Do not enter fire area without proper protective equipment, including respiratory protection. Hazardous Combustion Products: Decomposition may produce fumes, smoke, oxides of carbon and hydrocarbons. Reference to Other Sections Refer to section 9 for flammability properties. SECTION 6: ACCIDENTAL RELEASE MEASURES Personal Precautions, Protective Equipment and Emergency Procedures General Measures: Avoid all contact with skin, eyes, or clothing. Avoid breathing (vapor, mist, spray). Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level. Use special care to avoid static electric charges. Keep away from heat, sparks, open flames, hot surfaces. – No smoking. For Non-Emergency Personnel For Emergency Personnel Environmental Precautions Prevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters. Methods and Material for Containment and Cleaning Up For Containment: Contain any spills with dikes or absorbents to prevent migration and entry into sewers or streams. Do not take up in combustible material such as: saw dust or cellulosic material. Methods for Cleaning Up: Clear up spills immediately and dispose of waste safely. Spills should be contained with mechanical barriers. Transfer spilled material to a suitable container for disposal. Contact competent authorities after a spill. Use only non- sparking tools. Reference to Other Sections See Section 8, Exposure Controls and Personal Protection. See Section 13, Disposal Considerations. SECTION 7: HANDLING AND STORAGE Precautions for Safe Handling Additional Hazards When Processed: Flammable vapors may accumulate in the head space of closed systems. Container may remain hazardous when empty. Handle empty containers with care because residual vapors are flammable. Any proposed use of this product in elevated-temperature processes should be thoroughly evaluated to assure that safe operating conditions are established and maintained. Hygiene Measures: Handle in accordance with good industrial hygiene and safety procedures. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Conditions for Safe Storage, Including Any Incompatibilities Technical Measures: Proper grounding procedures to avoid static electricity should be followed. Ground/bond container and receiving equipment. Use explosion-proof electrical, ventilating, lighting equipment. Use only non-sparking tools. Storage Conditions: Store in a dry, cool and well-ventilated place. Keep container closed when not in use. Keep in fireproof place. Keep/Store away from direct sunlight, extremely high or low temperatures and incompatible materials. Incompatible Materials: Strong oxidizers. Strong acids. Alkalis. Attacks some forms of plastics, rubber, and coatings. Protective Equipment: Use appropriate personal protection equipment (PPE). Emergency Procedures: Evacuate unnecessary personnel. Protective Equipment: Equip cleanup crew with proper protection. Emergency Procedures: Upon arrival at the scene, a first responder is expected to recognize the presence of dangerous goods, protect oneself and the public, secure the area, and call for the assistance of trained personnel as soon as conditions permit. SDS # 4026 4/9 SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION Control Parameters For substances listed in section 3 that are not listed here, there are no established Exposure limits from the manufacturer, supplier, importer, or the appropriate advisory agency including: ACGIH (TLV), NIOSH (REL), OSHA (PEL), Canadian provincial governments, or the Mexican government. Methyl acetate (79-20-9) Mexico OEL TWA (mg/m³) 610 mg/m³ Mexico OEL TWA (ppm) 200 ppm Mexico OEL STEL (mg/m³) 760 mg/m³ Mexico OEL STEL (ppm) 250 ppm USA ACGIH ACGIH TWA (ppm) 200 ppm USA ACGIH ACGIH STEL (ppm) 250 ppm USA OSHA OSHA PEL (TWA) (mg/m³) 610 mg/m³ USA OSHA OSHA PEL (TWA) (ppm) 200 ppm USA NIOSH NIOSH REL (TWA) (mg/m³) 610 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 200 ppm USA NIOSH NIOSH REL (STEL) (mg/m³) 760 mg/m³ USA NIOSH NIOSH REL (STEL) (ppm) 250 ppm USA IDLH US IDLH (ppm) 3100 ppm (10% LEL) Alberta OEL STEL (mg/m³) 757 mg/m³ Alberta OEL STEL (ppm) 250 ppm Alberta OEL TWA (mg/m³) 606 mg/m³ Alberta OEL TWA (ppm) 200 ppm British Columbia OEL STEL (ppm) 250 ppm British Columbia OEL TWA (ppm) 200 ppm Manitoba OEL STEL (ppm) 250 ppm Manitoba OEL TWA (ppm) 200 ppm New Brunswick OEL STEL (mg/m³) 757 mg/m³ New Brunswick OEL STEL (ppm) 250 ppm New Brunswick OEL TWA (mg/m³) 606 mg/m³ New Brunswick OEL TWA (ppm) 200 ppm Newfoundland & Labrador OEL STEL (ppm) 250 ppm Newfoundland & Labrador OEL TWA (ppm) 200 ppm Nova Scotia OEL STEL (ppm) 250 ppm Nova Scotia OEL TWA (ppm) 200 ppm Nunavut OEL STEL (mg/m³) 760 mg/m³ Nunavut OEL STEL (ppm) 250 ppm Nunavut OEL TWA (mg/m³) 605 mg/m³ Nunavut OEL TWA (ppm) 200 ppm Northwest Territories OEL STEL (mg/m³) 760 mg/m³ Northwest Territories OEL STEL (ppm) 250 ppm Northwest Territories OEL TWA (mg/m³) 605 mg/m³ Northwest Territories OEL TWA (ppm) 200 ppm Ontario OEL STEL (ppm) 250 ppm Ontario OEL TWA (ppm) 200 ppm Prince Edward Island OEL STEL (ppm) 250 ppm Prince Edward Island OEL TWA (ppm) 200 ppm Québec VECD (mg/m³) 757 mg/m³ Québec VECD (ppm) 250 ppm SDS # 4026 5/9 Québec VEMP (mg/m³) 606 mg/m³ Québec VEMP (ppm) 200 ppm Saskatchewan OEL STEL (ppm) 250 ppm Saskatchewan OEL TWA (ppm) 200 ppm Yukon OEL STEL (mg/m³) 760 mg/m³ Yukon OEL STEL (ppm) 250 ppm Yukon OEL TWA (mg/m³) 610 mg/m³ Yukon OEL TWA (ppm) 200 ppm n-Heptane (142-82-5) USA ACGIH ACGIH TWA (ppm) 400 ppm USA ACGIH ACGIH STEL (ppm) 500 ppm USA OSHA OSHA PEL (TWA) (mg/m³) 2000 mg/m³ USA OSHA OSHA PEL (TWA) (ppm) 500 ppm USA NIOSH NIOSH REL (TWA) (mg/m³) 350 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 85 ppm USA NIOSH NIOSH REL (ceiling) (mg/m³) 1800 mg/m³ USA NIOSH NIOSH REL (ceiling) (ppm) 440 ppm USA IDLH US IDLH (ppm) 750 ppm Alberta OEL STEL (mg/m³) 2050 mg/m³ Alberta OEL STEL (ppm) 500 ppm Alberta OEL TWA (mg/m³) 1640 mg/m³ Alberta OEL TWA (ppm) 400 ppm British Columbia OEL STEL (ppm) 500 ppm British Columbia OEL TWA (ppm) 400 ppm Manitoba OEL STEL (ppm) 500 ppm Manitoba OEL TWA (ppm) 400 ppm New Brunswick OEL STEL (mg/m³) 2050 mg/m³ New Brunswick OEL STEL (ppm) 500 ppm New Brunswick OEL TWA (mg/m³) 1640 mg/m³ New Brunswick OEL TWA (ppm) 400 ppm Newfoundland & Labrador OEL STEL (ppm) 500 ppm Newfoundland & Labrador OEL TWA (ppm) 400 ppm Nova Scotia OEL STEL (ppm) 500 ppm Nova Scotia OEL TWA (ppm) 400 ppm Nunavut OEL STEL (mg/m³) 2049 mg/m³ Nunavut OEL STEL (ppm) 500 ppm Nunavut OEL TWA (mg/m³) 1640 mg/m³ Nunavut OEL TWA (ppm) 400 ppm Northwest Territories OEL STEL (mg/m³) 2049 mg/m³ Northwest Territories OEL STEL (ppm) 500 ppm Northwest Territories OEL TWA (mg/m³) 1640 mg/m³ Northwest Territories OEL TWA (ppm) 400 ppm Ontario OEL STEL (ppm) 500 ppm Ontario OEL TWA (ppm) 400 ppm Prince Edward Island OEL STEL (ppm) 500 ppm Prince Edward Island OEL TWA (ppm) 400 ppm Québec VECD (mg/m³) 2050 mg/m³ Québec VECD (ppm) 500 ppm Québec VEMP (mg/m³) 1640 mg/m³ Québec VEMP (ppm) 400 ppm Saskatchewan OEL STEL (ppm) 500 ppm SDS # 4026 6/9 Saskatchewan OEL TWA (ppm) 400 ppm Yukon OEL STEL (mg/m³) 2000 mg/m³ Yukon OEL STEL (ppm) 500 ppm Yukon OEL TWA (mg/m³) 1600 mg/m³ Yukon OEL TWA (ppm) 400 ppm Exposure Controls Appropriate Engineering Controls: Gas detectors should be used when flammable gases/vapors may be released. Proper grounding procedures to avoid static electricity should be followed. Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapor or mists below the applicable workplace exposure limits. Use explosion-proof equipment. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure. Ensure all national/local regulations are observed. Personal Protective Equipment: Protective goggles. Gloves. Protective clothing. Insufficient ventilation: wear respiratory protection. Materials for Protective Clothing: Chemically resistant materials and fabrics. Hand Protection: Wear chemically resistant protective gloves. Eye Protection: Chemical safety goggles. Skin and Body Protection: Wear suitable protective clothing. Respiratory Protection: If exposure limits are exceeded or irritation is experienced, approved respiratory protection should be worn. Environmental Exposure Controls: Do not allow the product to be released into the environment. Consumer Exposure Controls: Do not eat, drink, or smoke during use SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES Information on Basic Physical and Chemical Properties Physical State : Liquid Appearance : Clear Odor : Ester Odor Threshold : Not available pH : Not applicable Evaporation Rate : 5.3, based on methyl acetate [Ref Std: n-Butyl acetate = 1.0] Melting Point : Not available Freezing Point : Not available Boiling Point : 132.8 – 136.4 °F (56 - 58 °C) Flash Point : 8.6 °F (-13 °C) Auto-ignition Temperature : >500 °C (932 °F) Decomposition Temperature : Not available Flammability (solid, gas) : Not available Lower Flammable Limit : 3.1 % Upper Flammable Limit : 16.0 % Vapor Pressure : <=171 mm Hg @ 20 °C (68 °F) Relative Vapor Density at 20 °C : >= 2.0 [Ref Std: Air = 1.0] Relative Density : 0.92 g/mL Specific Gravity : 0.92 @ 20 °C (68 °F) Solubility : Not soluble in water Partition Coefficient: N-Octanol/Water : Not available Viscosity : Not applicable Solids Content : 0% (completely volatile) Explosion Data – Sensitivity to Mechanical Impact : Not expected to present an explosion hazard due to mechanical impact. Explosion Data – Sensitivity to Static Discharge : Yes, in certain circumstances product can ignite due to static discharge. SDS # 4026 7/9 VOC Content (SCAQMD Rule 1171) : ≤ 25 g/L VOC (Meets California VOC regulations for Solvent Cleaning of Adhesive Application Equipment) VHAP Content : 0 lbs/lb solids SECTION 10: STABILITY AND REACTIVITY Reactivity: Vapors are heavier than air and may travel considerable distance to an ignition source and flash back to source of vapors. Reacts with (strong) oxidizers: (increased) risk of fire. Chemical Stability: Stable under recommended handling and storage conditions (see section 7). Possibility of Hazardous Reactions: Hazardous polymerization will not occur. Conditions to Avoid: Direct sunlight. Extremely high or low temperatures. Ignition sources. Air contact. Incompatible materials. Incompatible Materials: Strong oxidizers. Strong acids. Alkalis. Attacks some forms of plastics, rubber, and coatings. Hazardous Decomposition Products: Decomposition may produce fumes, smoke, oxides of carbon and hydrocarbons. Oxides of Yttrium. SECTION 11: TOXICOLOGICAL INFORMATION Information on Toxicological Effects - Product Acute Toxicity: Not classified LD50 and LC50 Data: Not available Skin Corrosion/Irritation: Not classified Serious Eye Damage/Irritation: Causes serious eye irritation. Respiratory or Skin Sensitization: Not classified Germ Cell Mutagenicity: Not classified Teratogenicity: Not available Carcinogenicity: Not classified Specific Target Organ Toxicity (Repeated Exposure): Not classified Reproductive Toxicity: Not classified Specific Target Organ Toxicity (Single Exposure): May cause drowsiness or dizziness. Aspiration Hazard: Small amounts of this liquid drawn into the lungs from swallowing or vomitting may cause severe health effects. Symptoms/Injuries After Inhalation: May cause drowsiness or dizziness. Symptoms/Injuries After Skin Contact: Causes skin irritation. Redness, pain, swelling, itching, burning, dryness, and dermatitis. Symptoms/Injuries After Eye Contact: Causes eye irritation. Symptoms may include: Redness, pain, swelling, itching, burning, tearing, and blurred vision. Symptoms/Injuries After Ingestion: Ingestion is likely to be harmful or have adverse effects. Information on Toxicological Effects - Ingredient(s) LD50 and LC50 Data: Methyl acetate (79-20-9) LD50 Oral Rat > 5000 mg/kg LD50 Dermal Rabbit > 5 g/kg LC50 Inhalation Rat 16000 ppm/4h n-Heptane (142-82-5) LD50 Oral Rat > 5000 mg/kg LD50 Dermal Rabbit 3000 mg/kg LC50 Inhalation Rat 103 g/m³ (Exposure time: 4 h) SECTION 12: ECOLOGICAL INFORMATION Toxicity No additional information available Methyl acetate (79-20-9) LC50 Fish 1 295 - 348 mg/l (Exposure time: 96 h - Species: Pimephales promelas [flow-through]) EC50 Daphnia 1 1026.7 mg/l (Exposure time: 48 h - Species: Daphnia magna) LC 50 Fish 2 250 - 350 mg/l (Exposure time: 96 h - Species: Brachydanio rerio [static]) n-Heptane (142-82-5) LC50 Fish 1 375.0 mg/l (Exposure time: 96 h - Species: Cichlid fish) SDS # 4026 8/9 Persistence and Degradability Bioaccumulative Potential Mobility in Soil Not available Other Adverse Effects Other Information: Avoid release to the environment. SECTION 13: DISPOSAL CONSIDERATIONS Sewage Disposal Recommendations: This material is hazardous to the aquatic environment. Keep out of sewers and waterways. Waste Disposal Recommendations: Dispose of waste material in accordance with all local, regional, national, provincial, territorial and international regulations. Additional Information: Handle empty containers with care because residual product is flammable. SECTION 14: TRANSPORT INFORMATION In Accordance with DOT Proper Shipping Name : CHEMICAL UNDER PRESSURE, FLAMMABLE, N.O.S.(Methyl Acetate; Heptane) Hazard Class : 2.1 Identification Number : UN3501 Label Codes : 2.1 ERG Number : 115 In Accordance with TDG Proper Shipping Name : CHEMICAL UNDER PRESSURE, FLAMMABLE, N.O.S.(Methyl Acetate; Heptane) Hazard Class : 2.1 Identification Number : UN3501 Label Codes : 2.1 SECTION 15: REGULATORY INFORMATION US Federal Regulations SARA Section 311/312 Hazard Classes Immediate (acute) health hazard Fire hazard Methyl acetate (79-20-9) Listed on the United States TSCA (Toxic Substances Control Act) inventory EPA TSCA Regulatory Flag T - T - indicates a substance that is the subject of a Section 4 test rule under TSCA. Heptane, branched, cyclic and linear (426260-76-6) Listed on the United States TSCA (Toxic Substances Control Act) inventory n-Heptane (142-82-5) Listed on the United States TSCA (Toxic Substances Control Act) inventory EPA TSCA Regulatory Flag T - T - indicates a substance that is the subject of a Section 4 test rule under TSCA. Nitrogen (7727-37-9) Listed on the United States TSCA (Toxic Substances Control Act) inventory US State Regulations Methyl acetate (79-20-9) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List Methyl acetate (79-20-9) Log Pow 0.18 n-Heptane (142-82-5) Log Pow 4.66 SDS # 4026 9/9 n-Heptane (142-82-5) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List Canadian Regulations Methyl acetate (79-20-9) Listed on the Canadian DSL (Domestic Substances List) Listed on the Canadian IDL (Ingredient Disclosure List) IDL Concentration 1 % Heptane, branched, cyclic and linear (426260-76-6) Listed on the Canadian DSL (Domestic Substances List) n-Heptane (142-82-5) Listed on the Canadian DSL (Domestic Substances List) Listed on the Canadian IDL (Ingredient Disclosure List) IDL Concentration 1 % Nitrogen (7727-37-9) Listed on the Canadian DSL (Domestic Substances List) This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the SDS contains all of the information required by CPR. SECTION 16: OTHER INFORMATION, INCLUDING DATE OF PREPARATION OR LAST REVISION Revision Date : 06/06/2019 Other Information : This document has been prepared in accordance with the SDS requirements of the OSHA Hazard Communication Standard 29 CFR 1910.1200. GHS Full Text Phrases: H225 Highly flammable liquid and vapor H280 Contains gas under pressure; may explode if heated H304 May be fatal if swallowed or enters airways H315 Causes skin irritation H319 Causes serious eye irritation H336 May cause drowsiness or dizziness This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 4015 SDS Date: February 2023 SECTION 1: IDENTIFICATION Product Identifier Product Form: Mixture Product Name: EverGuard TPO Quick Spray Adhesive LV50 Intended Use of the Product Use of the Substance/Mixture: No use is specified. Name, Address, and Telephone of the Responsible Party Company GAF 1 Campus Drive Parsippany, NJ 07054 888-GAF-ROOF Emergency Telephone Number Emergency Number : CHEMTREC 1-800-424-9300 SECTION 2: HAZARDS IDENTIFICATION Classification of the Substance or Mixture Classification (GHS-US) Flam. Gas 1 H220 Compressed gas H280 Eye Irrit. 2A H319 STOT SE 3 H336 Full text of H-phrases: see section 16 Label Elements GHS-US Labeling Hazard Pictograms (GHS-US) : GHS02 GHS04 GHS07 Signal Word (GHS-US) : Danger Hazard Statements (GHS-US) : H220 - Extremely flammable gas. H280 - Contains gas under pressure; may explode if heated. H319 - Causes serious eye irritation. H336 - May cause drowsiness or dizziness. Precautionary Statements (GHS-US) : P210 - Keep away from extremely high or low temperatures, ignition sources, and incompatible materials. - No smoking. P261 - Avoid breathing gas. P264 - Wash hands, forearms, and other exposed areas thoroughly after handling. P271 - Use only outdoors or in a well-ventilated area. P280 - Wear respiratory protection, protective gloves, protective clothing, face protection, eye protection. P304+P340 - IF INHALED: Remove person to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. 1/11 ) 2/11 GAF SDS 4015 P312 - Call a poison center or doctor if you feel unwell. P337+P313 - If eye irritation persists: Get medical advice/attention. P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P381 - Eliminate all ignition sources if safe to do so. P403 - Store in a well-ventilated place. P403+P233 - Store in a well-ventilated place. Keep container tightly closed. Other Hazards Exposure may aggravate those with pre-existing eye, skin, or respiratory conditions. Flammable vapors can accumulate in head space of closed systems. Unknown Acute Toxicity (GHS-US) Not available SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS Mixture Name Product Identifier % (w/w) Methyl acetate (CAS No) 79-20-9 45 -70 Resin acids and rosin acids, esters with pentaerythritol (CAS No) 8050-26-8 10 – 30 Propane (CAS No) 74-98-6 5 – 10 Butane (CAS No) 106-97-8 5 – 10 Carbon dioxide (CAS No) 124-38-9 0.5 – 1.5 Heptane, branched, cyclic and linear (CAS No) 426260-76-6 0.5 – 1.5 n-Heptane (CAS No) 142-82-5 0.5 – 1.5 SECTION 4: FIRST AID MEASURES Description of First Aid Measures General: Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label if possible). Inhalation: Remove to fresh air and keep at rest in a position comfortable for breathing. Obtain medical attention if breathing difficulty persists. Skin Contact: Remove contaminated clothing. Rinse affected area with water for at least 5 minutes. Wash contaminated clothing before reuse. Obtain medical attention if irritation persists. Eye Contact: Rinse cautiously with water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Obtain medical attention. Ingestion: Do NOT induce vomiting. Rinse mouth. Immediately call a POISON CENTER or doctor/physician. Most Important Symptoms and Effects Both Acute and Delayed General: Causes serious eye irritation. May cause drowsiness and dizziness. Inhalation: May cause drowsiness or dizziness. Skin Contact: May cause skin irritation. Eye Contact: Causes serious eye irritation. Symptoms may include: Redness, pain, swelling, itching, burning, tearing, and blurred vision. Ingestion: Ingestion is likely to be harmful or have adverse effects. Chronic Symptoms: None expected under normal conditions of use. Indication of Any Immediate Medical Attention and Special Treatment Needed If you feel unwell, seek medical advice (show the label where possible). SECTION 5: FIRE-FIGHTING MEASURES Extinguishing Media Suitable Extinguishing Media: Water spray, fog, carbon dioxide (CO2), alcohol-resistant foam, dry chemical, or sand. Unsuitable Extinguishing Media: Do not use a heavy water stream. Use of heavy stream of water may spread fire. Special Hazards Arising From the Substance or Mixture Fire Hazard: Extremely flammable gas. Explosion Hazard: May form flammable/explosive vapor-air mixture. Reactivity: Reacts with (strong) oxidizers: (increased) risk of fire. ) 3/11 GAF SDS 4015 Advice for Firefighters Precautionary Measures Fire: Exercise caution when fighting any chemical fire. Under fire conditions, hazardous fumes will be present. Firefighting Instructions: Exercise caution when fighting any chemical fire. Leaking gas fire: Do not extinguish, unless leak can be stopped safely. In case of leaking gas fire, eliminate all ignition sources if safe to do so. Protection During Firefighting: Do not enter fire area without proper protective equipment, including respiratory protection. Hazardous Combustion Products: Burning can produce carbon monoxide, carbon dioxide, chloride and hydrocarbons. Carbon monoxide is highly toxic if inhaled; carbon dioxide in sufficient concentrations can act as an asphyxiant. Acute overexposure to the products of combustion may result in irritation of the respiratory tract. Reference to Other Sections Refer to section 9 for flammability properties. SECTION 6: ACCIDENTAL RELEASE MEASURES Personal Precautions, Protective Equipment and Emergency Procedures General Measures: Avoid all contact with skin, eyes, or clothing. Avoid breathing (vapor, mist, gas). Use special care to avoid static electric charges. Keep away from heat, sparks, open flames, hot surfaces. – No smoking. For Non-Emergency Personnel For Emergency Personnel Environmental Precautions Prevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters. Methods and Material for Containment and Cleaning Up For Containment: Contain any spills with dikes or absorbents to prevent migration and entry into sewers or streams. Do not take up in combustible material such as: saw dust or cellulosic material. Methods for Cleaning Up: Clean up spills immediately and dispose of waste safely. Spills should be contained with mechanical barriers. Transfer spilled material to a suitable container for disposal. Contact competent authorities after a spill. Use only non- sparking tools. Reference to Other Sections See Heading 8. Exposure controls and personal protection. For further information refer to section 13. SECTION 7: HANDLING AND STORAGE Precautions for Safe Handling Additional Hazards When Processed: Handle empty containers with care because residual vapors are flammable. Extremely flammable gas. Hygiene Measures: Handle in accordance with good industrial hygiene and safety procedures. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Conditions for Safe Storage, Including Any Incompatibilities Technical Measures: Proper grounding procedures to avoid static electricity should be followed. Ground/bond container and receiving equipment. Use explosion-proof electrical, ventilating, lighting equipment. Use only non-sparking tools. Storage Conditions: Store in a dry, cool and well-ventilated place. Keep container closed when not in use. Keep in fireproof place. Keep/Store away from direct sunlight, extremely high or low temperatures and incompatible materials. Incompatible Materials: Strong acids. Strong bases. Strong oxidizers. Specific End Use(s) No use is specified. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION Control Parameters Propane (74-98-6) USA NIOSH NIOSH REL (TWA) (mg/m³) 1800 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 1000 ppm USA IDLH US IDLH (ppm) 2100 ppm (10% LEL) Protective Equipment: Use appropriate personal protection equipment (PPE). Emergency Procedures: Evacuate unnecessary personnel. Protective Equipment: Equip cleanup crew with proper protection. Emergency Procedures: Stop leak if safe to do so. Eliminate ignition sources. Ventilate area. ) 4/11 GAF SDS 4015 USA OSHA OSHA PEL (TWA) (mg/m³) 1800 mg/m³ USA OSHA OSHA PEL (TWA) (ppm) 1000 ppm Butane (106-97-8) USA ACGIH ACGIH STEL (ppm) 1000 ppm USA NIOSH NIOSH REL (TWA) (mg/m³) 1900 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 800 ppm Methyl acetate (79-20-9) USA ACGIH ACGIH TWA (ppm) 200 ppm USA ACGIH ACGIH STEL (ppm) 250 ppm USA OSHA OSHA PEL (TWA) (mg/m³) 610 mg/m³ USA OSHA OSHA PEL (TWA) (ppm) 200 ppm USA NIOSH NIOSH REL (TWA) (mg/m³) 610 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 200 ppm USA NIOSH NIOSH REL (STEL) (mg/m³) 760 mg/m³ USA NIOSH NIOSH REL (STEL) (ppm) 250 ppm USA IDLH US IDLH (ppm) 3100 ppm (10% LEL) Alberta OEL STEL (mg/m³) 757 mg/m³ Alberta OEL STEL (ppm) 250 ppm Alberta OEL TWA (mg/m³) 606 mg/m³ Alberta OEL TWA (ppm) 200 ppm British Columbia OEL STEL (ppm) 250 ppm British Columbia OEL TWA (ppm) 200 ppm Manitoba OEL STEL (ppm) 250 ppm Manitoba OEL TWA (ppm) 200 ppm New Brunswick OEL STEL (mg/m³) 757 mg/m³ New Brunswick OEL STEL (ppm) 250 ppm New Brunswick OEL TWA (mg/m³) 606 mg/m³ New Brunswick OEL TWA (ppm) 200 ppm Newfoundland & Labrador OEL STEL (ppm) 250 ppm Newfoundland & Labrador OEL TWA (ppm) 200 ppm Nova Scotia OEL STEL (ppm) 250 ppm Nova Scotia OEL TWA (ppm) 200 ppm Nunavut OEL STEL (mg/m³) 760 mg/m³ Nunavut OEL STEL (ppm) 250 ppm Nunavut OEL TWA (mg/m³) 605 mg/m³ Nunavut OEL TWA (ppm) 200 ppm Northwest Territories OEL STEL (mg/m³) 760 mg/m³ Northwest Territories OEL STEL (ppm) 250 ppm Northwest Territories OEL TWA (mg/m³) 605 mg/m³ Northwest Territories OEL TWA (ppm) 200 ppm Ontario OEL STEL (ppm) 250 ppm Ontario OEL TWA (ppm) 200 ppm Prince Edward Island OEL STEL (ppm) 250 ppm Prince Edward Island OEL TWA (ppm) 200 ppm Québec VECD (mg/m³) 757 mg/m³ Québec VECD (ppm) 250 ppm Québec VEMP (mg/m³) 606 mg/m³ Québec VEMP (ppm) 200 ppm Saskatchewan OEL STEL (ppm) 250 ppm Saskatchewan OEL TWA (ppm) 200 ppm Yukon OEL STEL (mg/m³) 760 mg/m³ ) 5/11 GAF SDS 4015 Yukon OEL STEL (ppm) 250 ppm Yukon OEL TWA (mg/m³) 610 mg/m³ Yukon OEL TWA (ppm) 200 ppm Carbon dioxide (124-38-9) USA ACGIH ACGIH TWA (ppm) 5000 ppm USA ACGIH ACGIH STEL (ppm) 30000 ppm USA OSHA OSHA PEL (TWA) (mg/m³) 9000 mg/m³ USA OSHA OSHA PEL (TWA) (ppm) 5000 ppm USA NIOSH NIOSH REL (TWA) (mg/m³) 9000 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 5000 ppm USA NIOSH NIOSH REL (STEL) (mg/m³) 54000 mg/m³ USA NIOSH NIOSH REL (STEL) (ppm) 30000 ppm USA IDLH US IDLH (ppm) 40000 ppm Alberta OEL STEL (mg/m³) 54000 mg/m³ Alberta OEL STEL (ppm) 30000 ppm Alberta OEL TWA (mg/m³) 9000 mg/m³ Alberta OEL TWA (ppm) 5000 ppm British Columbia OEL STEL (ppm) 15000 ppm British Columbia OEL TWA (ppm) 5000 ppm Manitoba OEL STEL (ppm) 30000 ppm Manitoba OEL TWA (ppm) 5000 ppm New Brunswick OEL STEL (mg/m³) 54000 mg/m³ New Brunswick OEL STEL (ppm) 30000 ppm New Brunswick OEL TWA (mg/m³) 9000 mg/m³ New Brunswick OEL TWA (ppm) 5000 ppm Newfoundland & Labrador OEL STEL (ppm) 30000 ppm Newfoundland & Labrador OEL TWA (ppm) 5000 ppm Nova Scotia OEL STEL (ppm) 30000 ppm Nova Scotia OEL TWA (ppm) 5000 ppm Nunavut OEL STEL (mg/m³) 27000 mg/m³ Nunavut OEL STEL (ppm) 15000 ppm Nunavut OEL TWA (mg/m³) 9000 mg/m³ Nunavut OEL TWA (ppm) 5000 ppm Northwest Territories OEL STEL (mg/m³) 27000 mg/m³ Northwest Territories OEL STEL (ppm) 15000 ppm Northwest Territories OEL TWA (mg/m³) 9000 mg/m³ Northwest Territories OEL TWA (ppm) 5000 ppm Ontario OEL STEL (ppm) 30000 ppm Ontario OEL TWA (ppm) 5000 ppm Prince Edward Island OEL STEL (ppm) 30000 ppm Prince Edward Island OEL TWA (ppm) 5000 ppm Québec VECD (mg/m³) 54000 mg/m³ Québec VECD (ppm) 30000 ppm Québec VEMP (mg/m³) 9000 mg/m³ Québec VEMP (ppm) 5000 ppm Saskatchewan OEL STEL (ppm) 30000 ppm Saskatchewan OEL TWA (ppm) 5000 ppm Yukon OEL STEL (mg/m³) 27000 mg/m³ Yukon OEL STEL (ppm) 15000 ppm Yukon OEL TWA (mg/m³) 9000 mg/m³ Yukon OEL TWA (ppm) 5000 ppm ) 6/11 GAF SDS 4015 n-Heptane (142-82-5) USA ACGIH ACGIH TWA (ppm) 400 ppm USA ACGIH ACGIH STEL (ppm) 500 ppm USA OSHA OSHA PEL (TWA) (mg/m³) 2000 mg/m³ USA OSHA OSHA PEL (TWA) (ppm) 500 ppm USA NIOSH NIOSH REL (TWA) (mg/m³) 350 mg/m³ USA NIOSH NIOSH REL (TWA) (ppm) 85 ppm USA NIOSH NIOSH REL (ceiling) (mg/m³) 1800 mg/m³ USA NIOSH NIOSH REL (ceiling) (ppm) 440 ppm USA IDLH US IDLH (ppm) 750 ppm Alberta OEL STEL (mg/m³) 2050 mg/m³ Alberta OEL STEL (ppm) 500 ppm Alberta OEL TWA (mg/m³) 1640 mg/m³ Alberta OEL TWA (ppm) 400 ppm British Columbia OEL STEL (ppm) 500 ppm British Columbia OEL TWA (ppm) 400 ppm Manitoba OEL STEL (ppm) 500 ppm Manitoba OEL TWA (ppm) 400 ppm New Brunswick OEL STEL (mg/m³) 2050 mg/m³ New Brunswick OEL STEL (ppm) 500 ppm New Brunswick OEL TWA (mg/m³) 1640 mg/m³ New Brunswick OEL TWA (ppm) 400 ppm Newfoundland & Labrador OEL STEL (ppm) 500 ppm Newfoundland & Labrador OEL TWA (ppm) 400 ppm Nova Scotia OEL STEL (ppm) 500 ppm Nova Scotia OEL TWA (ppm) 400 ppm Nunavut OEL STEL (mg/m³) 2049 mg/m³ Nunavut OEL STEL (ppm) 500 ppm Nunavut OEL TWA (mg/m³) 1640 mg/m³ Nunavut OEL TWA (ppm) 400 ppm Northwest Territories OEL STEL (mg/m³) 2049 mg/m³ Northwest Territories OEL STEL (ppm) 500 ppm Northwest Territories OEL TWA (mg/m³) 1640 mg/m³ Northwest Territories OEL TWA (ppm) 400 ppm Ontario OEL STEL (ppm) 500 ppm Ontario OEL TWA (ppm) 400 ppm Prince Edward Island OEL STEL (ppm) 500 ppm Prince Edward Island OEL TWA (ppm) 400 ppm Québec VECD (mg/m³) 2050 mg/m³ Québec VECD (ppm) 500 ppm Québec VEMP (mg/m³) 1640 mg/m³ Québec VEMP (ppm) 400 ppm Saskatchewan OEL STEL (ppm) 500 ppm Saskatchewan OEL TWA (ppm) 400 ppm Yukon OEL STEL (mg/m³) 2000 mg/m³ Yukon OEL STEL (ppm) 500 ppm Yukon OEL TWA (mg/m³) 1600 mg/m³ Yukon OEL TWA (ppm) 400 ppm ) 7/11 GAF SDS 4015 Exposure Controls Appropriate Engineering Controls: Gas detectors should be used when flammable gases/vapors may be released. Proper grounding procedures to avoid static electricity should be followed. Use explosion-proof equipment. Ensure adequate ventilation, especially in confined areas. Emergency eye wash fountains and safety showers should be available in the immediate vicinity of any potential exposure. Ensure all national/local regulations are observed. Personal Protective Equipment: Protective goggles. Gloves. Face shield. Insufficient ventilation: wear respiratory protection. Full protective flameproof clothing. Materials for Protective Clothing: Chemically resistant materials and fabrics. Hand Protection: Wear chemically resistant protective gloves. Eye Protection: Chemical safety goggles. Skin and Body Protection: Wear suitable protective clothing. Respiratory Protection: Use a NIOSH-approved respirator or self-contained breathing apparatus whenever exposure may exceed established Occupational Exposure Limits. Environmental Exposure Controls: Do not allow the product to be released into the environment. Consumer Exposure Controls: Do not eat, drink or smoke during use SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES Information on Basic Physical and Chemical Properties Physical State : Liquid (Aerosol) Appearance : Light amber liquid Odor : Etherial odor Odor Threshold : Not available pH : Not applicable Evaporation Rate : Not available Melting Point : Not available Freezing Point : Not available Boiling Point : Propellant: -24.4 °C (-11.9 °F) ; Concentrate: 56°C (132.8 °F) Flash Point : -105 °C (-157 °F) (Tag Closed Cup) Auto-ignition Temperature : Concentrate: >465 °C (869 °F) Decomposition Temperature : Not available Flammability (solid, gas) : Not available Lower Flammable Limit : Propellant: 1.8%; Concentrate: 3.1% Upper Flammable Limit : Propellant: 9.5%; Concentrate: 16.0% Vapor Pressure : Propellant: 70 psig (3620 mmHg) @20 °C; Concentrate: 171 mmHg @20 °C Relative Vapor Density at 20 °C : Not available Relative Density : 0.96 g/mL (Concentrate) Specific Gravity : 0.96 @ 20 °C (Concentrate) Solubility : Not soluble in water Partition Coefficient: N-Octanol/Water : Not available Viscosity : Not available Explosion Data – Sensitivity to Mechanical Impact : Do not subject aerosol products to mechanical impact Explosion Data – Sensitivity to Static Discharge : Yes, in certain circumstances product can ignite due to static discharge. VOC Content (SCAQMD Rule 1168) : 77 g/L (0.63 lb/gal) VHAP Content : 0.0 lb/lb solids 02/07/2019 EN (English US) 8/11 GAF SDS 4015 SECTION 10: STABILITY AND REACTIVITY Reactivity: Reacts with (strong) oxidizers: (increased) risk of fire. Chemical Stability: Extremely flammable gas. Possibility of Hazardous Reactions: Hazardous polymerization will not occur. Conditions to Avoid: Direct sunlight. Extremely high or low temperatures. Open flame. Overheating. Heat. Sparks. Incompatible Materials: Strong acids. Strong bases. Strong oxidizers. Hazardous Decomposition Products: Carbon oxides (CO, CO2). Decomposition may produce fumes, smoke, oxides of carbon and hydrocarbons. SECTION 11: TOXICOLOGICAL INFORMATION Information on Toxicological Effects - Product Acute Toxicity: Not classified LD50 and LC50 Data: Not available Skin Corrosion/Irritation: Not classified Serious Eye Damage/Irritation: Causes serious eye irritation. Respiratory or Skin Sensitization: Not classified Germ Cell Mutagenicity: Not classified Teratogenicity: Not classified Carcinogenicity: Not classified Specific Target Organ Toxicity (Repeated Exposure): Not classified Reproductive Toxicity: Not classified Specific Target Organ Toxicity (Single Exposure): May cause drowsiness or dizziness. Aspiration Hazard: Not classified Symptoms/Injuries After Inhalation: May cause drowsiness or dizziness. Symptoms/Injuries After Skin Contact: May cause skin irritation. Symptoms/Injuries After Eye Contact: Causes serious eye irritation. Symptoms may include: Redness, pain, swelling, itching, burning, tearing, and blurred vision. Symptoms/Injuries After Ingestion: Ingestion is likely to be harmful or have adverse effects. Chronic Symptoms: None expected under normal conditions of use. Information on Toxicological Effects - Ingredient(s) LD50 and LC50 Data: Methyl acetate (79-20-9) LD50 Oral Rat > 5000 mg/kg LD50 Dermal Rabbit > 5 g/kg LC50 Inhalation Rat 16000 ppm/4h SECTION 12: ECOLOGICAL INFORMATION Toxicity No additional information available Methyl acetate (79-20-9) LC50 Fish 1 295 - 348 mg/l (Exposure time: 96 h - Species: Pimephales promelas [flow-through]) EC50 Daphnia 1 1026.7 mg/l (Exposure time: 48 h - Species: Daphnia magna) LC 50 Fish 2 250 - 350 mg/l (Exposure time: 96 h - Species: Brachydanio rerio [static]) n-Heptane (142-82-5) LC50 Fish 1 375.0 mg/l (Exposure time: 96 h - Species: Cichlid fish) Persistence and Degradability Bioaccumulative Potential Methyl acetate (79-20-9) Log Pow 0.18 Carbon dioxide (124-38-9) BCF Fish 1 (no bioaccumulation) Log Pow 0.83 9/11 GAF SDS 4015 n-Heptane (142-82-5) Log Pow 4.66 Mobility in Soil Not available Other Adverse Effects Other Information: Avoid release to the environment. SECTION 13: DISPOSAL CONSIDERATIONS Waste Disposal Recommendations: Dispose of waste material in accordance with all local, regional, national, provincial, territorial and international regulations. Additional Information: Handle empty containers with care because residual product is flammable. Ecology – Waste Materials: Avoid release to the environment. SECTION 14: TRANSPORT INFORMATION In Accordance with DOT Proper Shipping Name : CHEMICAL UNDER PRESSURE, FLAMMABLE, N.O.S.(Petroleum Gases, Liquefied; Methyl Acetate) Hazard Class : 2.1 Identification Number : UN3501 Label Codes : 2.1 ERG Number : 115 In Accordance with IMDG Proper Shipping Name : CHEMICAL UNDER PRESSURE, FLAMMABLE, N.O.S.(Petroleum Gases, Liquefied; Methyl Acetate) Hazard Class : 2 Identification Number : UN3501 Label Codes : 2.1 EmS-No. (Fire) : F-D EmS-No. (Spillage) : S-U In Accordance with IATA* Proper Shipping Name : CHEMICAL UNDER PRESSURE, FLAMMABLE, N.O.S. (Petroleum Gases, Liquefied; Methyl Acetate) Identification Number : UN3501 Hazard Class : 2.1 Label Codes : 2.1 *According to IATA, Forbidden to transport via passenger craft. If shipping on cargo aircraft, adhere to special provisions A1 and A187. In Accordance with TDG Proper Shipping Name : CHEMICAL UNDER PRESSURE, FLAMMABLE, N.O.S.(Petroleum Gases, Liquefied; Methyl Acetate) Hazard Class : 2.1 Identification Number : 3501 Label Codes : 2.1 SECTION 15: REGULATORY INFORMATION US Federal Regulations SARA Section 311/312 Hazard Classes Immediate (acute) health hazard Propane (74-98-6) Listed on the United States TSCA (Toxic Substances Control Act) inventory Butane (106-97-8) Listed on the United States TSCA (Toxic Substances Control Act) inventory Methyl acetate (79-20-9) Listed on the United States TSCA (Toxic Substances Control Act) inventory EPA TSCA Regulatory Flag T - T - indicates a substance that is the subject of a Section 4 test rule under TSCA. Resin acids and rosin acids, esters with pentaerythritol (8050-26-8) Listed on the United States TSCA (Toxic Substances Control Act) inventory 10/11 GAF SDS 4015 Carbon dioxide (124-38-9) Listed on the United States TSCA (Toxic Substances Control Act) inventory Heptane, branched, cyclic and linear (426260-76-6) Listed on the United States TSCA (Toxic Substances Control Act) inventory n-Heptane (142-82-5) Listed on the United States TSCA (Toxic Substances Control Act) inventory EPA TSCA Regulatory Flag T - T - indicates a substance that is the subject of a Section 4 test rule under TSCA. US State Regulations Propane (74-98-6) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List Butane (106-97-8) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List Methyl acetate (79-20-9) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List Carbon dioxide (124-38-9) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List n-Heptane (142-82-5) U.S. - Massachusetts - Right To Know List U.S. - New Jersey - Right to Know Hazardous Substance List U.S. - Pennsylvania - RTK (Right to Know) List Canadian Regulations Propane (74-98-6) Listed on the Canadian DSL (Domestic Substances List) Butane (106-97-8) Listed on the Canadian DSL (Domestic Substances List) Methyl acetate (79-20-9) Listed on the Canadian DSL (Domestic Substances List) Listed on the Canadian IDL (Ingredient Disclosure List) IDL Concentration 1 % Resin acids and rosin acids, esters with pentaerythritol (8050-26-8) Listed on the Canadian DSL (Domestic Substances List) Carbon dioxide (124-38-9) Listed on the Canadian DSL (Domestic Substances List) Listed on the Canadian IDL (Ingredient Disclosure List) IDL Concentration 1 % Heptane, branched, cyclic and linear (426260-76-6) Listed on the Canadian DSL (Domestic Substances List) 11/11 GAF SDS 4015 n-Heptane (142-82-5) Listed on the Canadian DSL (Domestic Substances List) Listed on the Canadian IDL (Ingredient Disclosure List) IDL Concentration 1 % This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the SDS contains all of the information required by CPR. SECTION 16: OTHER INFORMATION, INCLUDING DATE OF PREPARATION OR LAST REVISION Revision Date : 02/07/2019 Other Information : This document has been prepared in accordance with the SDS requirements of the OSHA Hazard Communication Standard 29 CFR 1910.1200. GHS Full Text Phrases: H220 Extremely flammable gas H280 Contains gas under pressure; may explode if heated H319 Causes serious eye irritation H336 May cause drowsiness or dizziness This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Safety Data Sheet SDS # 3213 SDS Date: October 2023 _________________________________________________________________________ Page 1 of 6 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAMES: Drill-Tec™#12 Fastener Drill-Tec™ #12 Fastener Hex Head Drill-Tec™ #14 Fastener Drill-Tec™ CD-10 Fastener Drill-Tec™ LD Fastener Drill-Tec™ Gyptec Fastener Drill-Tec™ Purlin Fastener Drill-Tec™ Hex Head Purlin Fastener Drill-Tec™ SXHD (#21) Drill-Tec™ XHD Fastener (#15) Drill-Tec™ ASAP 3S Drill-Tec™ Base Sheet Fastener (1.2 in.) Drill-Tec™ Base Sheet Fastener (1.7 in.) Drill-Tec™ Base Sheet Fastener E (1.2 in.) Drill-Tec™ Base Sheet Fastener E (1.7 in.) Drill-Tec™Locking Impact Nail Drill-Tec™Masonry Anchors Drill-Tec™ Extra Heavy Duty ASAP® Roofing Fastener – Insulation Drill-Tec™ LIP Termination Bar Drill-Tec™ FLAT Termination Bar Drill‑Tec™ LIP SE Termination Bar Drill-Tec™ 2.4" Scoop Seam Plate Drill-Tec™ 2 ⅜” Barbed XHD Plate Drill-Tec™ 2 3/4” Barbed SXHD Plate Drill-Tec™ 2 3/8” Doublel Barbed XHD Plate Drill-Tec™ 2” Doublel Barbed XHD Plate Drill-Tec™ 2” Steel Wall Plate Drill-Tec™ 3” Steel Plate (Recessed) Drill-Tec™ 3” Plastic Locking Plate Drill-Tec™ 3” Accutrac® Recessed Plate Drill-Tec™ 3” Accutrac® Flat Plate Drill-Tec™ 3” Ribbed Galvalume Plate (Flat) Drill-Tec™ 3” Standard Steel Plate (Flat) MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800 – 424 – 9300 INFORMATION ONLY: 877 – GAF – ROOF APPROVED BY: Corporate EHS GAF SDS # 3213 Page 2 of 6 SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. PRIMARY ROUTE OF EXPOSURE: Not applicable. SIGNS & SYMPTOMS OF EXPOSURE EYES: Not applicable. SKIN: Not applicable. INGESTION: Not applicable. INHALATION: Not applicable. ACUTE HEALTH HAZARDS: None. CHRONIC HEALTH HAZARDS: None. CARCINOGENICITY: Nickel is classified as a potential human carcinogen by IARC (“2b”, possibly carcinogenic to humans) and NTP (“K”, known to be a human carcinogen). ACGIH, by contrast, classifies nickel metal as “A5” (not suspected as a human carcinogen). SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER Chromium 7429-90-5 <1-2 Not applicable to this form of the product Not applicable to this form of the product Not applicable to this form of the product Iron 7440-50-8 91-99 NE NE NE Manganese 7439-96-5 <1-2 Not applicable to this form of the product Not applicable to this form of the product Not applicable to this form of the product GAF SDS # 3213 Page 3 of 6 Nickel 7440-02-0 <1-2 Not applicable to this form of the product Not applicable to this form of the product Not applicable to this form of the product Zinc 7440-66-6 <1-2 NE NE NE NE = Not Established SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Not applicable. SKIN: Not applicable. INHALATION: Not applicable. INGESTION: Not applicable. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: Not applicable. SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Material does not burn. Use ABC type fire extinguisher for surrounding fire. HAZARDOUS COMBUSTION PRODUCTS: None known. RECOMMENDED FIRE FIGHTING PROCEDURES: For large fire involving this material, fire fighters should use self-contained breathing apparatus. UNUSUAL FIRE & EXPLOSION HAZARDS: None known. SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: Not applicable. SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Not applicable. GAF SDS # 3213 Page 4 of 6 OTHER PRECAUTIONS: Not applicable. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / VENTILATION: Not applicable. RESPIRATORY PROTECTION: Not applicable. EYE PROTECTION: Safety glasses with side shields. SKIN PROTECTION: Work gloves. OTHER PROTECTIVE EQUIPMENT: Not applicable. WORK HYGIENIC PRACTICES: Not applicable. EXPOSURE GUIDELINES: Not applicable. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Solid FLASH POINT: Not applicable. LOWER EXPLOSIVE LIMIT: Not applicable. METHOD USED: Not applicable. UPPER EXPLOSIVE LIMIT: Not applicable. EVAPORATION RATE: Not applicable. BOILING POINT: Not applicable. pH (undiluted product): Not applicable. MELTING POINT: No Data SOLUBILITY IN WATER: Insoluble. SPECIFIC GRAVITY: Not applicable. VAPOR DENSITY: Not applicable. PERCENT VOLATILE: Not applicable. VAPOR PRESSURE: Not applicable. MOLECULAR WEIGHT: Not applicable. VOC WITH WATER (LBS/GAL): Not applicable. WITHOUT WATER (LBS/GAL): Not applicable. SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE UNSTABLE GAF SDS # 3213 Page 5 of 6 CONDITIONS TO AVOID (STABILITY): Not applicable. INCOMPATIBILITY (MATERIAL TO AVOID): Ammonium nitrate; peroxides; lithium; nitric oxide; chlorates; sulfur dioxide; halogens; chlorine trifluoride; nitrogen dioxide; sulfur; carbides; hydrazine; nitric acid; hydrazoic acid; dioxane; selenium; performic acid; phosphorus; titanium plus potassium perchlorate. HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: Not applicable. HAZARDOUS POLYMERIZATION: Will not occur. __________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. _________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: Dispose in accordance with all applicable local, state and Federal regulations. SECTION 14: TRANSPORTATION INFORMATION DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. GAF SDS # 3213 Page 6 of 6 SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: All components are listed on the TSCA inventory. CERCLA: Not applicable. SARA Not applicable. CALIFORNIA PROPOSITION 65: Not applicable. SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: August 2020. CHANGES SINCE PREVIOUS SDS: Product list update. This information relates to the specific material designated and may not be valid for such material used in combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents. GAF Corporation Safety Data Sheet SDS #3212 SDS Date: October 2019 _________________________________________________________________________ Page 1 of 6 SECTION 1: PRODUCT AND COMPANY INFORMATION PRODUCT NAMES: Barbed SXHD Plate, Drill-Tec™ 2 3/8 in. Barbed XHD Plate, Drill-Tec™ 2 in. Barbed Plate, Drill-Tec™ 2 in. Double Barbed XHD Plate, Drill-Tec™ 2" Gyptec Plate, Drill-Tec™ 2-3/4” Eyehook Seam Plate, Drill-Tec™ 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec™ 3" Gyptec Plate Drill-Tec™ 3" Plastic Locking Plate, Drill-Tec™ 3" Standard Steel Plate, Drill-Tec™ 3" Steel Plate, Drill-Tec™ AccuTrac® Flat Plate, Drill-Tec™ AccuTrac® Recessed Plate, Drill-Tec™ Eyehook AccuSeam Plate, Drill-Tec™ LD Plate, Drill-Tec™ Plastic Plate, Drill-Tec™ RhinoBond® PVC XHD Plate, Drill-Tec™ RhinoBond® PVC XHD Tread Safe Plate, Drill-Tec™ Extra Heavy Duty ASAP Assembled Screw and 2-3/8 in. Steel Plate, Drill-Tec™ Heavy Duty ASAP 2S Assembled Screw and 2 in. Steel Plate, Drill-Tec™ Heavy Duty ASAP Roofing Fastener Assembled with a 3" Metal Plate, Drill-Tec™ Heavy Duty ASAP Roofing Fastener Assembled with a 3" Plastic Plate MANUFACTURER: GAF ADDRESS: 1 Campus Drive, Parsippany, NJ 07054 24-HOUR EMERGENCY PHONE (CHEMTREC): 800 – 424 – 9300 INFORMATION ONLY: 800 – 766 – 3411 PREPARED BY: Corporate EHS APPROVED BY: Corporate EHS SECTION 2: HAZARDS IDENTIFICATION As defined in the OSHA Hazard Communication Standard, 29 CFR 1910.1200, the products listed below are considered articles and do not require an SDS. In addition, articles are not included in the scope of the Globally Harmonization System (GHS). As such, the GHS labeling elements are not included on this SDS. All components listed for this product are bound within the product. When handled as intended GAF SDS # 3212 Page 2 of 6 and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. Although these products are not subject to the OSHA Standard or GHS labeling elements, GAF would like to disclose as much health and safety information as possible to ensure that this product is handled and used properly. This SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and be made available for employees and other users of this product. In addition, the recommendations for handling and use of these products should be included in worker training programs. PRIMARY ROUTE OF EXPOSURE: Not applicable. SIGNS & SYMPTOMS OF EXPOSURE EYES: Not applicable. SKIN: Not applicable. INGESTION: Not applicable. INHALATION: Not applicable. ACUTE HEALTH HAZARDS: None. CHRONIC HEALTH HAZARDS: None. CARCINOGENICITY: Not applicable. SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS OCCUPATIONAL EXPOSURE LIMITS CHEMICAL NAME CAS # % (BY WT) OSHA ACGIH OTHER Aluminum 7429-90-5 Not Applicable Not applicable to this form of the product Not applicable to this form of the product Not applicable to this form of the product Ethylene-propylene Copolymer 9010-79-1 Not Applicable NE NE NE Iron 7440-50-8 Not Applicable NE NE NE Manganese 7439-96-5 Not Applicable Not applicable to this form of the product Not applicable to this form of the product Not applicable to this form of the product Zinc 7440-66-6 Not Applicable NE NE NE NE = Not Established GAF SDS # 3212 Page 3 of 6 SECTION 4: FIRST AID MEASURES FIRST AID PROCEDURES EYES: Not applicable. SKIN: Not applicable. INHALATION: Not applicable. INGESTION: Not applicable. NOTES TO PHYSICIANS OR FIRST AID PROVIDERS: Not applicable. SECTION 5: FIRE FIGHTING PROCEDURES SUITABLE EXTINGUISHING MEDIA: Material does not burn. Use ABC type fire extinguisher for surrounding fire. HAZARDOUS COMBUSTION PRODUCTS: None known. RECOMMENDED FIRE FIGHTING PROCEDURES: For large fire involving this material, fire fighters should use self-contained breathing apparatus. UNUSUAL FIRE & EXPLOSION HAZARDS: None known. SECTION 6: ACCIDENTAL RELEASE MEASURES ACCIDENTAL RELEASE MEASURES: Not applicable. SECTION 7: HANDLING AND STORAGE HANDLING AND STORAGE: Not applicable. OTHER PRECAUTIONS: Not applicable. SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS / Not applicable. GAF SDS # 3212 Page 4 of 6 VENTILATION: RESPIRATORY PROTECTION: Not applicable. EYE PROTECTION: Safety glasses with side shields. SKIN PROTECTION: Work gloves. OTHER PROTECTIVE EQUIPMENT: Not applicable. WORK HYGIENIC PRACTICES: Not applicable. EXPOSURE GUIDELINES: Not applicable. SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES APPEARANCE & ODOR: Solid FLASH POINT: Not applicable. LOWER EXPLOSIVE LIMIT: Not applicable. METHOD USED: Not applicable. UPPER EXPLOSIVE LIMIT: Not applicable. EVAPORATION RATE: Not applicable. BOILING POINT: Not applicable. pH (undiluted product): Not applicable. MELTING POINT: No Data SOLUBILITY IN WATER: Insoluble. SPECIFIC GRAVITY: Not applicable. VAPOR DENSITY: Not applicable. PERCENT VOLATILE: Not applicable. VAPOR PRESSURE: Not applicable. MOLECULAR WEIGHT: Not applicable. VOC WITH WATER (LBS/GAL): Not applicable. WITHOUT WATER (LBS/GAL): Not applicable. SECTION 10: STABILITY AND REACTIVITY THERMAL STABILITY: STABLE UNSTABLE CONDITIONS TO AVOID (STABILITY): Not applicable. INCOMPATIBILITY (MATERIAL TO AVOID): Ammonium nitrate; peroxides; lithium; nitric oxide; chlorates; sulfur dioxide; halogens; chlorine trifluoride; nitrogen dioxide; sulfur; carbides; hydrazine; nitric acid; hydrazoic acid; dioxane; selenium; performic acid; phosphorus; titanium plus potassium perchlorate. GAF SDS # 3212 Page 5 of 6 HAZARDOUS DECOMPOSITION OR BY- PRODUCTS: Not applicable. HAZARDOUS POLYMERIZATION: Will not occur. __________________________________________________________________________________________ SECTION 11: TOXICOLOGICAL INFORMATION TOXICOLOGICAL INFORMATION: No information available. SECTION 12: ECOLOGICAL INFORMATION ECOLOGICAL INFORMATION: No information available. __________________________________________________________________________________________ SECTION 13: DISPOSAL CONSIDERATIONS WASTE DISPOSAL METHOD: This product, as supplied, is not regulated as a hazardous waste by the U.S. Environmental Protection Agency (EPA) under Resource Conservation and Recovery Act (RCRA) regulations. Comply with state and local regulations for disposal. RCRA HAZARD CLASS: None SECTION 14: TRANSPORTATION INFORMATION DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. GAF SDS # 3212 Page 6 of 6 SECTION 15: REGULATORY INFORMATION U.S. FEDERAL REGULATIONS TSCA: All components are listed on the TSCA inventory. CERCLA: Not applicable. SARA Not applicable. CALIFORNIA PROPOSITION 65: Not applicable. SECTION 16: OTHER INFORMATION ADDITIONAL COMMENTS: None. DATE OF PREVIOUS SDS: New SDS. CHANGES SINCE PREVIOUS SDS: None. This information relates to the specific material designated and may not be valid for such material used on combination with any other materials or in any process. Such information is to the best of our knowledge and belief accurate and reliable as of the date compiled. However, no representation, warranty or guarantee, expressed or implied, is made as to its accuracy, reliability, or completeness. It is the user’s responsibility to satisfy himself as to the suitability and completeness of such information for his particular use. We do not accept liability for any loss or damage that may occur from the use of this information. Nothing herein shall be construed as a recommendation for uses which infringe valid patents or as extending a license of valid patents.