Loading...
HomeMy WebLinkAbout20250518 East Ave, Covell Ave, North Ave Final Subdivision Revised PlansEast Avenue Subdivision East Ave, Saratoga Springs, NY 12866 SHEET INDEX: COVER S1 SUBDIVISION PLAN C-1.0 SITE PREPARATION AND DEMOLITION PLAN C-2.0 SITE LAYOUT PLAN C-3.0 UTILITY AND GRADING PLAN C-4.0 SITE DETAILS C-4.1 SITE DETAILS CITY OF SARATOGA SPRINGS STANDARD NOTES 40 Long Alley Saratoga Springs New York 12866 P 518/587-8100 F 518/587-0180 www.thelagroup.com June 12, 2025 PROJECT LOCATION MAP: PROJECT VICINITY MAP: PREPARED BY:SURVEYOR: Gilbert VanGuilder Land Surveyor, PLLC 988 Route 146 Clifton Park, NY 12065 (518) 383-0634 APPLICANT: Jayco New Build, LLC 14 Dakota Drive Gansevoort, NY 12831 NY-2 9 E A S T A V E SITE STATISTICS PROPOSED USE: SINGLE FAMILY RESIDENTIAL TAX MAP PARCEL PARCEL SIZE 166.5-2-36, 166.5-2-41, 166.5-2-43 0.23 AC, 0.32 AC, 0.44 AC ZONING DISTRICT UR-2: URBAN RESIDENTIAL MIN.LOT AREA 6,600 S.F. MIN.AVERAGE WIDTH (FT):60 FT MAX.BUILDING COVERAGE 40% MAX.IMPERVIOUS SURFACE COVERAGE 70% MAX.BUILDING HEIGHT 40 FT MIN.FRONT SETBACK 10 FT MIN.INTERIOR SIDE SETBACK 8 FT MIN.TOTAL INTERIOR SIDE SETBACK 20 FT MIN.REAR SETBACK 25 FT Planning Board # 20250518 Approval Approved under authority of a resolution adopted _____________________ by the Planning Board of the City of Saratoga Springs. Chairperson _________________________________________________ Date Signed:_________________________________________________ 1.ALL WORK MUST CONFORM TO ALL FEDERAL, STATE AND CITY CODES, SPECIFICATIONS, ORDINANCES, RULES AND REGULATIONS. 2.THE ELEVATION BASE FOR THE CONTOURS AND BENCHMARKS ARE BASED ON THE NATIONAL GEODETIC VERTICAL DATUM, 1929. 3.THE APPLICANT MUST SUBMIT A LETTER OF CREDIT ESTIMATE FOR PROJECT SITE WORK TO THE CITY ENGINEER FOR REVIEW AND APPROVAL. LETTER OF CREDIT FUNDS MUST BE POSTED WITH THE CITY PRIOR TO PLANNING BOARD CHAIR SIGNATURE ON FINAL PLAN. 4.THE CONTRACTOR MUST SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE CITY ENGINEER PRIOR TO ANY CONSTRUCTION. CONSTRUCTION INSPECTIONS BY A DESIGNATED REPRESENTATIVE OF THE APPLICANT ARE REQUIRED. THE COST OF THE CONSTRUCTION INSPECTIONS IS THE RESPONSIBILITY OF THE APPLICANT/DEVELOPER. 5.ALL PROPOSED EASEMENTS OR RIGHT-OF-WAY DEDICATIONS MUST BE VERIFIED AND APPROVED BY THE CITY ENGINEER PRIOR TO CONSTRUCTION. 6.THE APPLICANT MUST VERIFY THAT THE PROPOSED PROJECT CAN ACCOMMODATE THE TURNING MOVEMENTS OF ANY FIRE TRUCK THAT THE FIRE DEPARTMENT DESIGNATES. 7.THE CONTRACTOR MUST OBTAIN A STREET OPENING PERMIT FROM THE DEPARTMENT OF PUBLIC WORKS FOR ANY WORK WITHIN THE STREET OR RIGHT-OF-WAY OF ANY CITY STREET, ROAD OR ALLEY. 8.CONTACT THE BUILDING INSPECTOR FOR A BLASTING PERMIT, IF BLASTING IS REQUIRED 9.ALL POINTS OF CONSTRUCTION INGRESS OR EGRESS SHALL BE MAINTAINED TO PREVENT TRACKING OR FLOWING OF SEDIMENT OR DEBRIS ONTO A PUBLIC RIGHT-OF-WAY. ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES ALSO APPLY. 10.NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED UNTIL ALL SITE WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE APPROVED PLANS; ALL DISTURBED SOILS OR BARE GROUND HAVE BEEN FULLY STABILIZED; AND AN AS-BUILT DRAWING HAS BEEN PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY ENGINEER. SKIDMORE COLLEGE PROJECT SITE PROJECT SITE NORT H A V E COVE L L A V E MA P L E A V E EAST A V E MA P L E A V E COVE L L A V E NY-29 NY-2 9 E A S T A V E NY-29 BR O A D W A Y NO R T H B R O A D W A Y SARATOGA CITY CENTER E A S T A V E Revised August 27, 2025 5756 58 59 60 61 62 27282930313233 55 CLEAR AND GRUB ALL VEGETATION AS REQUIRED TO FACILITATE CONSTRUCTION CONSTRUCTION ENTRANCE 1 C-4.0 SILT FENCE3 C-4.0 CONCRETE WASHOUT 2 C-4.0 REMOVE ASPHALT PAVEMENT, TYP. REMOVE ASPHALT PAVEMENT, TYP. SAWCUT SAWCUT SAWCUT SAWCUT SA W C U T SA W C U T 15.00' 10 5 10 15 20200 Scale: 1" = 20' LEGEND PROPERTY LINE Planning Board # 20250518 Approval Approved under authority of a resolution adopted _____________________ by the Planning Board of the City of Saratoga Springs. Chairperson _________________________________________________ Date Signed:_________________________________________________ REMOVE ITEM SILT FENCE 1.EXISTING CONDITIONS ARE TAKEN FROM A SURVEY PLAN DATED 3/26/2025, AS PREPARED BY GILBERT VANGUILDER. HORIZONTAL AND VERTICAL DATUM IS AS NOTED ON THE PROJECT SURVEY. 2.PRIOR TO COMMENCING ANY EXCAVATION WORK, THE CONTRACTOR SHALL CONTACT U.F.P.O. (1-800-962-7962) AND THE PROPER LOCAL AUTHORITIES OR RESPECTIVE UTILITY COMPANY HAVING JURISDICTION TO CONFIRM THE LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. ANY COSTS INCURRED BY THE CONTRACTOR DUE TO FAILURE TO CONTACT THE PROPER AUTHORITIES SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 3.THE LOCATIONS OF ALL UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (WALLS, FENCE, FOOTINGS, TREE ROOTBALLS, PROPOSED LIGHTING FOOTINGS, ETC.). EXCAVATION REQUIRED WITHIN PROXIMITY OF UTILITY LINES SHALL BE DONE BY HAND. ANY DAMAGE AND INCURRED COSTS DUE TO FAILURE OF THE CONTRACTOR TO CONTACT THE PROPER AUTHORITIES SHALL BE BORNE BY THE CONTRACTOR. 4.THE GENERAL CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS IN THE FIELD AND REPORT ANY DISCREPANCY BETWEEN THE PLANS AND THE ACTUAL FIELD CONDITIONS TO THE OWNER'S REPRESENTATIVE. 5.THE CONTRACTOR SHALL ESTABLISH PERMANENT BENCH MARKS. MAINTAIN ALL ESTABLISHED BOUNDS AND BENCH MARKS AND REPLACE AS DIRECTED ANY WHICH ARE DESTROYED OR DISTURBED. 6.CONTRACTOR SHALL EMPLOY SPECIAL CARE IN SCHEDULING CONSTRUCTION SO AS TO MAINTAIN EXISTING VEHICULAR TRAFFIC PATTERNS, AND MINIMIZE DISRUPTION TO SURROUNDING PEDESTRIAN TRAFFIC. CONTRACTOR SHALL EMPLOY SPECIAL CARE TO PROTECT SAFETY OF PEDESTRIANS INSIDE AND OUTSIDE OF THE LIMIT OF WORK LINE. 7.IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL REQUIRED PERMITS FROM ALL JURISDICTIONS AFFECTED BY THIS WORK ARE IN PLACE PRIOR TO CONSTRUCTION. FOR PERMITS ALREADY ISSUED, CONTRACTOR SHALL OBTAIN COPIES OF PERMITS AND STRICTLY ADHERE TO PERMIT CONDITIONS. PERMITS THAT ARE OUTSTANDING SHALL BE SECURED BY THE CONTRACTOR AND COORDINATED WITH THE OWNER'S REPRESENTATIVE. 8.SHOULD ANYTHING BE OMITTED FROM THE PLANS WHICH IS NECESSARY FOR A COMPLETE UNDERSTANDING OF THE WORK, OR SHALL ANY ERROR APPEAR IN THE VARIOUS INSTRUMENTS FURNISHED OR IN THE WORK BY OTHER CONTRACTORS AFFECTING THE WORK COVERED HEREBY, THE CONTRACTOR SHALL AND WILL PROMPTLY NOTIFY THE OWNER'S REPRESENTATIVE, AND IN THE EVENT OF THE CONTRACTOR'S FAILURE TO DO SO, HE SHALL AND WILL MAKE GOOD OF ANY DAMAGE OR DEFECT IN HIS WORK CAUSED THEREBY. 9.CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF ALL EXISTING INFRASTRUCTURE FOR THE DURATION OF CONSTRUCTION. CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT, ROADWAYS AND DRIVEWAYS. 10.CONTRACTOR TO COMPLY WITH ALL OSHA AND OTHER STATE AND LOCAL SAFETY REQUIREMENTS DURING CONSTRUCTION. 11.CONTRACTOR SHALL MAINTAIN PROPER SIGNS, BARRICADES, FENCES, TO PROPERLY PROTECT THE WORK, EQUIPMENT, PERSONS AND PROPERTY FROM DAMAGE. ALL DAILY TRAFFIC IN THE VICINITY OF THE SITE SHALL NOT BE IMPEDED. 1.PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ARRANGE PRE-CONSTRUCTION MEETING WITH OWNER/OWNER'S REPRESENTATIVE AND THE CITY OF SARATOGA SPRINGS TO REVIEW ALL APPLICABLE PERMIT CONDITIONS, THE CONSTRUCTION PLANS AND GENERAL CONSTRUCTION SCHEDULE. 2.ALL EROSION CONTROL MEASURES SHALL BE IN PLACE PRIOR TO ANY EARTH DISTURBING ACTIVITIES. 3.THE GENERAL CONTRACTOR SHALL COORDINATE ALL ADJUSTMENT OR ABANDONMENT OF UTILITIES WITH THE RESPECTIVE UTILITY COMPANY AND PAY ALL ASSOCIATED COSTS. 1.CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE INSIDE AND OUTSIDE THE LIMIT OF WORK DUE TO THEIR CONTRACT OPERATIONS. 2.CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT, ROADWAYS AND DRIVEWAYS. 3.CONTRACTOR SHALL MAINTAIN NECESSARY TRAFFIC CONTROL DEVICES, DRUMS, DELINEATORS, SIGNS, FENCES, AND BARRICADES IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL MUTCD WITH NYS SUPPLEMENT TO PROPERLY PROTECT WORK, EQUIPMENT, PERSONS, AND PROPERTY FROM DAMAGE. 4.AT ALL LOCATIONS WHERE EXISTING PAVEMENT ABUTS NEW CONSTRUCTION, THE EDGE OF THE EXISTING PAVEMENT SHALL BE SAW CUT TO A CLEAN, SMOOTH AND SHARP EDGE AND PROTECTED UNTIL ABUTTING MATERIALS ARE INSTALLED. 1.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S REPRESENTATIVE ON ALL MATERIALS TO BE REMOVED AND RECYCLED/DISPOSED OF OFF SITE. ALL HANDLING OF MATERIALS TO BE REMOVED, RECYCLED, OR DISPOSED OF MUST BE DONE SO IN A SAFE, LEGAL MANNER, IN ACCORDANCE WITH ALL LOCAL, COUNTY, STATE, FEDERAL AND ANY OTHER APPLICABLE REGULATIONS. 2.ALL ITEMS REQUIRING REMOVAL SHALL BE REMOVED TO FULL DEPTH TO INCLUDE BASE MATERIAL AND FOOTINGS OR FOUNDATIONS AS APPLICABLE UNLESS OTHERWISE NOTED. 3.TREE, SHRUB AND VEGETATION REMOVAL SHALL INCLUDE THE FILLING, CUTTING, GRUBBING OUT OF ENTIRE ROOT SYSTEM AND SATISFACTORY OFF-SITE DISPOSAL OF ALL TREES, SHRUBS, STUMPS, VEGETATIVE AND EXTRANEOUS DEBRIS PRODUCED THROUGH THE REMOVAL OPERATIONS. FELL TREES IN SUCH A WAY AS TO NOT DAMAGE ADJACENT BUILDINGS OR OTHER TREES TO BE SAVED. 4.CONTRACTOR SHALL STRIP AND STOCKPILE EXISTING TOPSOIL TO FULL DEPTH WITHIN LIMIT OF GRADING BEFORE COMMENCING EXCAVATION AND GRADING OPERATIONS. TOPSOIL SHALL NOT BE REMOVED FROM THE SITE, UNLESS APPROVED BY THE OWNER'S REPRESENTATIVE. SITE PREPARATION NOTES PROTECTION NOTES: REMOVALS NOTES Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Jayco New Build, LLC 14 Dakota Drive Gansevoort, NY 12831 East Ave Subdivision East Ave Saratoga Springs NY, 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2025025 GENERAL NOTES SITE PREPARATION AND DEMOLITIONPLAN C-1.0 DRC MLD DRC 6/12/2025 1"=20' 1 City Comments 08/27/25 REMOVE PAVEMENT CLEAR AND GRUB VEGETATION SAW CUT PROPOSED BUILDING ASPHALT DRIVEWAY, TYP. RESIDENTIAL DROP CURB, TYP. 4 C-4.0 4 C-4.1 CONCRETE SIDEWALK, TYP.6 C-4.0 PROPOSED SETBACK PROPOSED PROPERTY LINE LOT 1 8052 S.F. 6 NORTH AVE LOT 2 7000 S.F. 8 NORTH AVE LOT 3 7000 S.F. 10 NORTH AVE LOT 4 7000 S.F. 12 NORTH AVE LOT 6 6953 S.F. 75 COVELL AVE LOT 5 7368 S.F. 73 COVELL AVE 10' FRONT SETBACK 10' FRONT SETBACK 1 0 ' F R O N T S E T B A C K 10' FRONT SETBACK 10' FRONT SETBACK 10' FRONT SETBACK 10' FRONT SETBACK 1 0 ' F R O N T S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 10 ' S I D E S E T B A C K 25' REAR SETBACK25' REAR SETBACK 25' REAR SETBACK 25' REAR SETBACK 25' REAR SETBACK25' REAR SETBACK EXISTING STREET LIGHT EXISTING STREET LIGHT DECORATIVE STREET LIGHT8 C-4.0 DECORATIVE STREET LIGHT8 C-4.0 1 AS 1 AS 1 AS 1 AS 2 PO 2 TA 2 QR 2 TA ASPHALT PAVEMENT 4 C-4.0 DETECTABLE WARNING PLATE DETECTABLE WARNING PLATE 1 PO 2 MR ASPHALT PAVEMENT PATCH MATCH EXISTING SIDEWALK, FLUSH EXISTING SIDEWALK NORTH AVE MAPL E A V E 166.5-2-43 166.5-2-41 166.5- 2-36 166.29-1-65 166.5-2-38 US ROUTE 9 E A S T A V E COVELL AVE 166.5-5-1 166.5-5-2 166.5-1-2.111 166.5-2-33 166.5-2-32 166.5- 2-42 16 6 . 5 - 2- 1 7 16 6 . 5 - 2 - 1 6 16 6 . 5 - 2 - 1 5 16 6 . 5 - 2 - 1 4 16 6 . 5 - 2 - 2 6 16 6 . 5 - 2 - 2 7 16 6 . 2 9 -1 - 2 1 16 6 . 2 9 -1 - 1 7 166.29- 1-77 166.29-1-18 1 6 6 . 2 1 - 1 - 1 1 166 . 2 1 - 1 - 8 166. 2 1 - 1 - 9 166.21-1-10 16 6 . 5 - 2 - 1 3 16 6 . 5 - 2 - 3 9 E A S T A V E EXCELSIO R A V E MA P L E D E L L BRY A N S T 10 5 10 15 20200 Scale: 1" = 20' LEGEND Planning Board # 20250518 Approval Approved under authority of a resolution adopted _____________________ by the Planning Board of the City of Saratoga Springs. Chairperson _________________________________________________ Date Signed:_________________________________________________ Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Jayco New Build, LLC 14 Dakota Drive Gansevoort, NY 12831 East Ave Subdivision East Ave Saratoga Springs NY, 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2025025 SITE LAYOUT PLAN C-2.0 DRC MLD DRC 6/12/2025 1"=20' 1 City Comments 08/27/25 1.ALL LINE AND GRADE INFORMATION SHALL BE LAID OUT BY A NEW YORK STATE REGISTERED SURVEYOR ENGAGED BY THE CONTRACTOR. 2.ALL NEW WORK SHALL BE STAKED OUT PRIOR TO CONSTRUCTION. THE OWNER'S REPRESENTATIVE SHALL BE NOTIFIED OF ANY DISCREPANCIES. FIELD ADJUSTMENTS MUST BE APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION. 3.ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES FROM WHICH THEY ARE MEASURED UNLESS OTHERWISE NOTED. 4.CONTRACTOR SHALL COORDINATE LOCATION OF ALL UTILITIES (LINES, DUCTS, CONDUITS, SLEEVES, FOOTINGS, ETC.) WITH LOCATIONS OF PROPOSED LANDSCAPE ELEMENTS (WALLS, FENCE, FOOTINGS, TREE ROOTBALLS, PROPOSED LIGHTING FOOTINGS, ETC.). CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. LAYOUT NOTES EXISTING PROPERTY LINE PROPOSED ASPHALT PAVEMENT NEW PROPERTY LINE PROPERTY SETBACK PROPOSED CONCRETE SIDEWALK DECORATIVE STREET LIGHT PLANT LIST SYM.QTY.BOTANICAL NAME COMMON NAME SIZE REMARKS/SPACING DECIDUOUS TREES AS 4 Amelanchier x grandiflora 'Autumn Brilliance'Autumn Brilliance Serviceberry2"-2 1/2" Cal.B&B, TREE FORM MR 2 Malus 'Robinson'Robinson Crabapple 2"-2 1/2" Cal.B&B PO 3 Platanus x acerifolia 'Exclamation'Exclamation London Planetree 2"-2 1/2" Cal.B&B TA 4 Tilia americana American Basswood 2"-2 1/2" Cal.B&B QR 2 Quercus Rubra Northern Red Oak 2"-2 1/2" Cal.B&B 50 150 2502500 Scale: 1" = 250' PROPERTIES WITHIN 300 FEET: EXPANSION JOINTCONTROL JOINT 5756 58 59 60 61 62 27282930313233 55 LOT 1 FFE: 309.00 LOT 2 FFE: 309.50 LOT 3 FFE: 312.00 LOT 4 FFE: 313.00 LOT 6 FFE: 307.00 LOT 5 FFE: 303.00 EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT 3/4" CURB STOP, TYP. 6" SPR-35 PVC MIN 2% SLOPE 6" SPR-35 PVC MIN 2% SLOPE 3/4" TYPE K COPPER WATER SERVICE, TYP. 3/4" CURB STOP, TYP. 3/4" TYPE K COPPER WATER SERVICE, TYP. PRIOR TO CONSTRUCTION CONTRACTOR SHALL LOCATE EXISTING WATER AND SEWER MAIN PRIOR TO CONSTRUCTION CONTRACTOR SHALL LOCATE EXISTING WATER AND SEWER MAIN REPORTED LOCATION OF 4" WATER MAIN REPORTED LOCATION OF 6" WATER MAIN 10 5 10 15 20200 Scale: 1" = 20' LEGEND Planning Board # 20250518 Approval Approved under authority of a resolution adopted _____________________ by the Planning Board of the City of Saratoga Springs. Chairperson _________________________________________________ Date Signed:_________________________________________________ Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Jayco New Build, LLC 14 Dakota Drive Gansevoort, NY 12831 East Ave Subdivision East Ave Saratoga Springs NY, 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2025025 UTILITY AND GRADING PLAN C-3.0 DRC MLD DRC 6/12/2025 1"=20' 1 City Comments 08/27/25 1.EXISTING BASE INFORMATION DERIVED FROM FIELD SURVEY DATED 3/26/2025, AS PREPARED BY GILBERT VANGUILDER. 2.PITCH EVENLY BETWEEN SPOT GRADES. ALL PAVED AREAS MUST PITCH TO DRAIN AT A MINIMUM SLOPE OF ONE-EIGHTH INCH (1/8") PER FOOT. MAXIMUM CROSSPITCH OF ALL SIDEWALKS IS 2%. ANY DISCREPANCIES NOT ALLOWING THIS TO OCCUR SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. 3.MAXIMUM CROSSPITCH OF ALL SIDEWALKS IS 2%. RAMPS SHALL NOT EXCEED 1 IN 12 OR 30' IN LENGTH. ANY DISCREPANCIES NOT ALLOWING THIS TO OCCUR SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUING WORK. 4.WHERE NEW PAVING MEETS EXISTING PAVING, NEW PAVING SHALL MEET THE LINE AND GRADE OF THE EXISTING PAVING. 5.EXCAVATION REQUIRED WITHIN 3 FEET OF EXISTING UTILITY LINE SHALL BE DONE BY HAND. CONTRACTOR SHALL REPAIR ANY DAMAGE TO EXISTING UTILITY LINES OR STRUCTURES INCURRED DURING CONSTRUCTION OPERATIONS AT NO ADDITIONAL COST TO OWNER. 6. OWNER. TOPSOIL SHALL BE STOCKPILED FOR RE-USE ON SITE OR LEGALLY DISPOSED OF OFFSITE. 7.ALL AREAS REQUIRING FILL SHALL BE BROUGHT TO REQUIRED GRADE IN 6" MAXIMUM COMPACTED LIFTS. GENERAL FILL SHALL BE FREE OF DELETERIOUS MATERIAL, CONTAIN NO GRAVEL LARGER THAN 2", AND SHALL BE COMPACTED IN ACCORDANCE WITH PROJECT PLANS AND DETAILS. 8.GRADE AREAS ADJACENT TO BUILDING LINES TO DRAIN AWAY FROM STRUCTURE AND PREVENT PONDING. FINISH SURFACES SHALL BE FREE FROM IRREGULAR SURFACE CHANGES. 9.SLOPE SIDES OF EXCAVATIONS TO COMPLY WITH LOCAL CODES AND ORDINANCES HAVING JURISDICTION AND OSHA REGULATIONS. MAINTAIN SIDE SLOPES OF EXCAVATIONS IN A SAFE CONDITION UNTIL COMPLETION OF BACKFILLING. 10.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY INTO EXISTING, PROVIDING VERTICAL CURVES OR ROUNDINGS AT ALL TOP AND BOTTOM OF SLOPES. 11.THE GENERAL CONTRACTOR SHALL MAINTAIN OR ADJUST TO NEW FINISH GRADE AS NECESSARY ALL UTILITY AND SITE STRUCTURES SUCH AS LIGHT POLES, SIGN POLES, MAN HOLES, CATCH BASINS, HAND HOLES, WATER AND GAS GATES, HYDRANTS, ETC., FROM MAINTAINED UTILITY AND SITE SYSTEMS UNLESS OTHERWISE NOTED ON THE UTILITY DRAWINGS OR AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 12.IN ALL LAWN AREAS, ROUGH GRADE SHALL BE BROUGHT TO WITHIN 4" OF FINISHED GRADE UNLESS OTHERWISE NOTED. GRADING NOTES 1.PVC SANITARY SEWERS, FITTINGS AND SERVICE LATERALS TO PROPERTY LINES SHALL CONFORM TO AND BE INSTALLED AND TESTED IN ACCORDANCE WITH THE CITY OF SARATOGA SPRINGS STANDARDS. 2.ALL SEWER PIPING AND FITTINGS SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR PVC PIPE, ASTM DESIGNATION D-3034-78 OR LATEST REVISION AND TO THE DIMENSIONS AND TOLERANCES OF CLASSIFICATION SDR-26 WITH SINGLE GASKET PUSH-ON JOINTS. 3.INFORMATION AND SHOP DRAWINGS FOR MATERIALS USED SHALL BE SUBMITTED TO AND APPROVED BY THE DESIGN ENGINEER PRIOR TO THE PLACEMENT OF ANY ORDERS OF SAID MATERIALS. 4.FIELD ADJUSTMENTS SHALL BE APPROVED BY THE LA GROUP AND THE CITY OF SARATOGA SPRINGS, PRIOR TO INSTALLATIONS. 1.WATER MAINS AND SERVICES SHALL BE INSTALLED AT A MINIMUM DEPTH OF COVER BELOW FINISHED GRADE OF 5'-0". 2.THERE SHALL BE A MINIMUM HORIZONTAL SEPARATION OF TEN FEET (EDGE TO EDGE) BETWEEN ANY WATER MAIN AND ANY SANITARY OR STORM SEWER. THERE SHALL ALSO BE A MINIMUM VERTICAL SEPARATION OF EIGHTEEN INCHES BETWEEN ANY WATER MAIN AND ANY SANITARY OR STORM SEWER. 3.NEW WATER SERVICES FROM MAIN TO CURB STOP WILL BE INSTALLED WITH MINIMUM COVER SHOWN ON STANDARD DETAILS UNLESS ADJUSTMENT IS REQUIRED BECAUSE OF DEPTH OF EXISTING WATER MAIN. SERVICE SHALL BE BROUGHT TO MINIMUM DEPTH IN STANDARD DETAILS AS CLOSE TO THE MAIN AS POSSIBLE. 4.DURING ALL EXCAVATION IN WHICH THE EXISTING WATER MAIN IS OR CAN EASILY BE EXPOSED, THE CONTRACTOR SHALL LOCATE THE WATER LINE, BOTH HORIZONTALLY AND VERTICALLY. THIS INFORMATION SHALL BE PROVIDED TO THE CITY OF SARATOGA SPRINGS AND INCORPORATED IN THE AS-BUILT DRAWINGS. 5.THE CONTRACTOR SHALL PROVIDE ID TAPE ABOVE WATER LINES AS SHOWN ON THE TRENCHING DETAIL. 6.WATER VALVE BOXES, EXISTING STRUCTURE RIMS, NEW STRUCTURE RIMS, ETC., SHALL BE ADJUSTED TO CONFORM TO NEW FINISHED PAVEMENT GRADES UNLESS OTHERWISE NOTED AND/OR DIRECTED BY THE OWNER'S REPRESENTATIVE. 1.THE CONTRACTOR SHALL CONTACT U.F.P.O. (1-800-962-7962) AND THE PROPER LOCAL AUTHORITIES OR RESPECTIVE UTILITY COMPANY HAVING JURISDICTION TO CONFIRM THE LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. ANY COSTS INCURRED BY THE CONTRACTOR DUE TO FAILURE TO CONTACT THE PROPER AUTHORITIES SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 2.CONTRACTOR SHALL COORDINATE ALL REQUIRED UTILITY INSPECTIONS BY THE AUTHORITY HAVING JURISDICTION IN ACCORDANCE WITH THEIR RESPECTIVE REQUIREMENTS. 3.LOCATION OF UTILITY CONNECTIONS AT BUILDING TO BE VERIFIED BASED ON FINAL BUILDING FOOTPRINT CONFIGURATION. 4.ALL UTILITY INSTALLATIONS SHALL BE IN ACCORDANCE WITH ALL REGULATORY, LOCAL MUNICIPAL AND BUILDING CODE REQUIREMENTS. 5.CONTRACTOR SHALL PROTECT AND SUSTAIN IN NORMAL SERVICE ALL EXISTING UTILITIES, STRUCTURES, EQUIPMENT ROADWAYS AND DRIVEWAYS FOR THE DURATION OF CONSTRUCTION. WATER NOTES UTILITY NOTES EXISTING PROPERTY LINE NEW PROPERTY LINE PROPERTY SETBACK EXISTING GAS LINE EXISTING SANITARY LINE PROPOSED SANITARY LINE PROPOSED WATER LINE EXISTING WATER LINE EXISTING STORM DRAIN PROPOSED STORM DRAIN SANITARY SEWER NOTES NOTES: 1.TACK COAT BINDER COURSE BEFORE PLACING TOP COURSE IF MORE THAN 48 HOURS HAVE ELAPSED AFTER PLACING THE BINDER COURSE. PAVEMENT TYPE TOP COURSE BINDER COURSE GRAVEL COURSE SUBGRADE - COMPACTED TO 90% STANDARD PROCTOR COMPACTED GRAVEL - NYSDOT TYPE 2 (SECT. 304) COMPACTED TO 95% STANDARD PROCTOR BINDER COURSE - NYSDOT ITEM 402.198902 - 19F9 H.M.A., 80 SERIES COMPACTION PG BINDER (LIQUID ASPHALT) GRADE SHALL BE PG-64-22 TACK COAT - NYSDOT ITEM 407-0102 DILUTED TOP COURSE - NYSDOT ITEM 402.098302 - 9.5F3 H.M.A., 80 SERIES COMPACTION STANDARD ROADWAY 1-1/2"3"12" PROPOSED PAVING EXISTING PAVING TO REMAIN 12" KEYED PAVEMENT TO BE FLUSH WITH EXISTING PAVEMENT TO REMAIN NOTE: THIS DETAIL IS FOR NEW BITUMINOUS PAVEMENT ADJACENT TO EXISTING BITUMINOUS PAVEMENT TO REMAIN. 1 1/2" MINIMUM DEEP KEY INTO EXISTING PAVEMENT EXISTING BASE MATERIAL COMPACTED SUBGRADE PROPOSED BASE COURSE. SEE ASPHALT PAVEMENT DETAIL PROPOSED BINDER COURSE PROPOSED TOP COURSE Scale: NTS PAVEMENT KEY5 Scale: NTS ASPHALT PAVEMENT4 Planning Board # 20250518 Approval Approved under authority of a resolution adopted _____________________ by the Planning Board of the City of Saratoga Springs. Chairperson _________________________________________________ Date Signed:_________________________________________________ STRAWBALES STAKED INTO GROUND NOTE: 1.WASHOUT AREA SHALL BE SIZED BY THE CONTRACTOR TO ADEQUATELY CONTAIN CONCRETE CLEANOUT. 2.SIGN INDICATING LOCATION OF CONCRETE WASHOUT SHALL BE PROVIDED AT EACH LOCATION. 10 MIL PLASTIC LINING WOOD OR METAL STAKES (2 PER BALE) STAPLES (2 PER BALE) STRAW BALE 10 MIL PLASTIC LINING 30'-0" OF 12" 50/50 MIXTURE OF TYPE 3 AND TYPE 4 GRANULAR MATERIAL OVER COMPACTED SUBGRADE R . 3 5 ' - 0 " T Y P . 12 ' - 0 " EDGE OF EXISTING ROADWAY 30'-0" 16 " A B O V E GR A D E 6" BE L O W G R A D E 10' MAX. ℄ TO ℄ 36" MIN., 2" HARDWOOD FENCE POSTS, DRIVEN MIN. 16" INTO GROUND 2' O V E R A L L FA B R I C H T . 20 " M I N . 16 " M I N . 36" MIN. FENCE POST FILTER FABRIC FLOW 6" MI N . EMBED FILTER CLOTH MIN. 8" INTO GROUNDSECTION PERSPECTIVE VIEW FILTER FABRIC; FASTENED SECURELY TO FENCE POSTS W/ STAPLES FLOW FLOW NOTES: 1.MINIMUM STONE SIZE SHALL BE 1"-4" STONE, INSTALLED OVER FILTER FABRIC TO A MINIMUM DEPTH OF 6". 2.ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ACCESSES SHALL BE PIPED BENEATH ACCESS. IF IMPRACTICAL, A MOUNTABLE DIVERSION BERM PREVENTING RUNOFF ONTO ADJACENT ROAD SHALL BE PERMITTED. 3.ACCESS SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY, ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED ONTO PUBLIC RIGHTS-OF-WAY SHALL BE REMOVED IMMEDIATELY. 4.ALL VEHICLE WASHING SHALL BE DONE IN A STONE STABILIZED AREA WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 5.INSPECT AND MAINTAIN AS NEEDED TO CONFORM TO SPECIFICATIONS AND STORMWATER POLLUTION PREVENTION PLAN. 8' ( M I N . ) 8' (MIN.) 2' (M I N . ) NOTES: 1.WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES OR STAPLES. POSTS SHALL BE STEEL EITHER "T" OR "U" TYPE OR HARDWOOD. 2.FILTER CLOTH TO BE TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY 24" AT TOP AND MID SECTION. FENCE SHALL BE WOVEN WIRE, 12 1/2 GAUGE, 6" MAXIMUM MESH OPENING. 3.WHEN TWO SECTIONS OF FILTER CLOTH ADJOIN EACH OTHER THEY SHALL BE OVER- LAPPED BY SIX INCHES AND FOLDED. FILTER CLOTH SHALL BE EITHER FILTER X, MIRAFI 100X, STABILINKA T140N, OR APPROVED EQUIVALENT. 4.PREFABRICATED UNITS SHALL BE GEOFAB, ENVIROFENCE, OR APPROVED EQUIVALENT. 5.MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED WHEN 1/3 HEIGHT OF SILT FENCE IS REACHED OR WHEN "BULGES" DEVELOP IN THE SILT FENCE. CONCRETE WASHOUT CONCRETE WASHOUT SIGN Scale: NTS STABILIZED CONSTRUCTION ENTRANCE1 Scale: NTS CONCRETE WASHOUT2 Scale: NTS SILT FENCE3 1.) SIDEWALKS MUST BE PLACED IN THE PUBLIC RIGHT OF WAY AT THE PROPERTY LINE. 2.) SIDEWALKS MUST NOT DROP DOWN WHEN CROSSING A DRIVEWAY. 3.) SIDEWALKS MUST NOT EXTEND ACROSS PUBLIC STREETS OR ALLEYS. 1.) ALL SIDEWALK INSTALLATIONS MUST BE DESIGNED BY A PROFESSIONAL ENGINEER. PLANS MUST BE APPROVED BY THE COUNTY COMM. OF PUBLIC WORKS. 2.) SIDEWALKS MUST BE PLACED ON THE BACK SIDE OF DITCHES OR 8'(MIN.) FROM THE EDGE OF SHOULDER. 3.) SIDEWALKS MUST BE CONSTRUCTED SO AS NOT TO INTERFERE WITH DRAINAGE. GENERAL DESIGN CRITERIA FOR CONSTRUCTING SIDEWALKS WITHIN SARATOGA SPRINGS RIGHT OF WAYS: GENERAL DESIGN CRITERIA FOR CONSTRUCTING SIDEWALKS WITHIN SARATOGA COUNTY RIGHT OF WAYS WITHIN SARATOGA SPRINGS: NOTES: EXPANSION JOINT SPACING - 20'-25' O.C. CONTROL JOINT SPACING - 5' O.C. NOMINAL CROSS SLOPE - 1/8" TO 1/4" PER FOOT (MAX. SLOPE 1:50 TYP.) TOWARDS STREET OR A.O.B.E. MAX. SLOPE ALONG THE LENGTH OF THE WALK SHOULD NOT EXCEED 1:12 CONSTRUCTION JOINT DETAILS TO BE SUBMITTED AND APPROVED BY CITY ENGINEER SIDEWALK WIDTH TO BE 5' MIN. OR AS ORDERED BY CITY ENGINEER THESE GENERAL CONCRETE SPECIFICATIONS SHALL APPLY TO ALL CONCRETE WORK WITHIN THE CITY OF SARATOGA SPRINGS INSTALLED WITHIN A CITY RIGHT-OF-WAY AND/OR WITHIN THE APPROVAL AUTHORITY MINIMUM SPECIFICATIONS. ALL CONCRETE THAT MAY COME IN CONTACT WITH DEICING CHEMICALS SHALL MEET OR EXCEED THESE CONCRETE SHALL BE ONLY PORTLAND CEMENT CONCRETE AIR-ENTRAINED OF DURABLE MATERIALS AND SHALL HAVE (1) A LOW WATER-CEMENT RATIO (MAXIMUM 0.46), (2) A SLUMP OF 4 INCHES OR LESS,* (3) A CEMENT CONTENT OF 606 LB PER CUBIC YARD OR MORE, (4) PROPER FINISHING AFTER BLEED WATER HAS EVAPORATED FROM THE SURFACE, (5) ADEQUATE DRAINAGE WITH A SLOPE OF 1/8 INCH PER LINEAR FOOT OR MORE, (6) A MINIMUM OF 7 DAYS MOIST CURING AT OR ABOVE 50 DEGREES F, (7) A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS, AND (8) A MINIMUM 30-DAY DRYING PERIOD AFTER MOIST CURING IF CONCRETE IS PLACED IN THE FALL AND WILL BE EXPOSED TO FREEZE-THAW CYCLES AND DEICERS WHEN SATURATED. THE EXACT LENGTH OF TIME FOR SUFFICIENT DRYING TO TAKE PLACE MAY VARY WITH CLIMATE AND WEATHER CONDITIONS. TECHNICAL SPECIFICATIONS FOR CONCRETE AS HEREIN DEFINED SHALL COMPLY WITH THE APPLICABLE SPECIFICATIONS OF THE "NEW YORK STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS CONSTRUCTION AND MATERIALS", 1985. ANY CLARIFICATION, REVISIONS, MODIFICATIONS THERETO SHALL ONLY BE MADE SUBJECT TO APPROVAL OF THE CITY OF SARATOGA SPRINGS PLANNING BOARD. *A SUPER PLASTICIZER MAY BE USED TO INCREASE SLUMP AND WORKABILITY WITHOUT INCREASING THE WATER-CEMENT RATIO. CITY OF SARATOGA SPRINGS CONCRETE SPECIFICATIONS OF THE PLANNING BOARD TYPE 1 TYPICAL PEDESTRIAN TRAFFIC LOADING NOTES: EXPANSION JOINT SPACING - 20'-25' O.C. CONTROL JOINT SPACING - 5' O.C. NOMINAL CROSS SLOPE - 1/8" TO 1/4" PER FOOT (MAX. SLOPE 1:50 TYP.) TOWARDS STREET OR A.O.B.E. MAX. SLOPE ALONG THE LENGTH OF THE WALK SHOULD NOT EXCEED 1:12 CONSTRUCTION JOINT DETAILS TO BE SUBMITTED AND APPROVED BY CITY ENGINEER SIDEWALK WIDTH TO BE 5' MIN. OR AS ORDERED BY CITY ENGINEER TYPE 2 VEHICLE TRAFFIC LOADING ACROSS DRIVEWAYS BROOM FINISH PERPENDICULAR TO WALK 4" CONCRETE - SEE CONCRETE SPECIFICATIONS 6" X 6" NO 6 6 WOVEN WIRE MESH EXCEPT A.O.B.E. 6" GRANULAR SUBBASE COURSE NYS DOT SECT. 304, TYPE 4 COMPACTED TO 95% STANDARD PROCTOR SUBGRADE COMPACTED TO 90% STANDARD PROCTOR BROOM FINISH PERPENDICULAR TO WALK 6" CONCRETE - SEE CONCRETE SPECIFICATIONS 6" X 6" NO 6 6 WOVEN WIRE MESH EXCEPT A.O.B.E. 8" GRANULAR SUBBASE COURSE NYS DOT SECT. 304, TYPE 4 COMPACTED TO 95% STANDARD PROCTOR SUBGRADE COMPACTED TO 90% STANDARD PROCTOR Scale: NTS CONCRETE PAVEMENT ON GRADE6 CAST ALUMINUM FINIAL AND ROOF SAME FINISH AS POLE 4ARC22T5-MDL03 LED: 64 WATT 2200 COLOR TEMPERATURE, TYPE 5 DISTRIBUTION, 120-277 VOLT DIMMABLE DRIVER ACRYLIC ACORN LENS 5T TWIST LOCK FITTER DRIVER COMPARTMENT 4" - 3" DIA. TAPERED POLE, .125 WALL THICKNESS, 6063-T6 STRUCTURAL GRADE ALUMINUM ACCESS DOOR CATALOG NUMBER: PT-D650SRLED-5T-4AR22T5- MDL03-A-PEC/4214T4/BK 17" DIA. BASE WITH 0.750" FLOOR THICKNESS, FOUR ANCHOR BOLTS AND ONE GROUND STUD. 12 ' - 0 " 3 4" CHAMFER 3" 24 " M I N . 4' - 0 " M I N . 20" FINISHED GRADE ZINC PLATED ANCHOR BOLT ASSEMBLY PER MANUFACTURER'S RECOMMENDATION 2" PVC SCHEDULE 40 NO DIRECT BURIAL GROUND ROD PER N.E.C. 4000 PSI CONCRETE BASE WITH SONOTUBE FIBER FROM 20" DIA. UNDISTURBED SUBGRADE OR COMPACTED TO 90% STANDARD PROCTOR NOTES: 1.INSTALLATION OF DECORATIVE LIGHTS SHALL BE COORDINATED WITH THE CITY ELECTRICIAN AND DEPARTMENT OF PUBLIC WORKS. (USE 120V POWER) 2.THE OWNER / DEVELOPER IS RESPONSIBLE FOR PAYING CONNECTION CHARGES FROM NATIONAL GRID. THE CITY OF SARATOGA SPRINGS TAKES OVER THE LIGHT ONCE CONNECTED. 3.ELECTRIC SERVICE: SWEEPS AT CONCRETE BASES AND BETWEEN BASES USE 2" SCHEDULE 40 PVC NON-METALLIC CONDUIT. UNLESS UNDER DRIVEWAYS WHERE SCHEDULE 80 PVC IS REQUIRED. FOR WIRE: THHN COPPER STRANDED NUMBER 6 COLORED RED, WHITE, AND GREEN. LIGHTS ARE WIRED 120 VOLTS. PROVIDE A SEPARATE HANDHOLE, SYNERTECH SYN121212HH02, TO BE OWNED BY THE CITY FOR THE DISCONNECT NEAR THE BASE OF THE ELECTRIC POLE OR BOX AT THE BEGINNING OF SERVICE. PROVIDE AND INSTALL (1) 5/8 INCH COPPER GROUND ROD IN HANDHOLE. WIRE AND CONDUIT FROM HANDHOLE TO POLE OR BOX PER NATIONAL GRID'S STANDARDS. IF CONNECTING ONLY ONE LIGHT PROVIDE WATERTIGHT FUSEHOLDER, FERRAZ SHAWMUT FEB-21-21 1P 600V WITH 5 AMP FUSE WITH INSULATOR BOOTS PART FRZ FSB1 IN HANDHOLE FOR FUSING THE POWER WIRE. IF CONNECTING MORE THAN ONE LIGHT PUT A 30 AMP FUSE IN WATERTIGHT FUSEHOLDER IN HANDHOLE AND PROVIDE SEPARATE FUSE HOLDERS, BUSSMAN HEB-AA FUSEHOLDER WITH 5 AMP FUSE, IN BASE OF EACH LAMP. RUN #12 THHN COPPER, (RED, WHITE AND GREEN) FROM BASE TO TOP OF LIGHT. USE POLARIS CONNECTORS FOR CONNECTIONS IN HANDHOLE AND IN BASE OF LIGHTS. THE LIGHT IS TO BE MOUNTED DIRECTLY INTO CONCRETE BASE USING FENDER WASHERS, 2 INCH OD 1/2 INCH ID AND 1/8 INCH THICKNESS, AND LOCK WASHERS. ELECTRONIC PHOTOCELL (STREET SIDE) POLE WELDED FOR SINGLE UNIT CONSTRUCTION BLACK FINISH 14 ' - 8 3 4" 17" DIA. BASE, 12" DIA BOLT CIRCLE, DIAMOND PATTERN, FOUR 1 2" x 18" ANCHOR BOLTS Scale: NTS DECORATIVE STREET LIGHT8 Scale: NTS TREE PLANTING7 Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Jayco New Build, LLC 14 Dakota Drive Gansevoort, NY 12831 East Ave Subdivision East Ave Saratoga Springs NY, 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2025025 SITE DETAILS C-4.0 DRC MLD DRC 6/12/2025 1"=20' 1 City Comments 08/27/25 FULL LENGTH OF PIPE CENTERED ON SEWER LINE 18 " M I N . 5' - 0 " M I N . * SEE NOTE WATER LINE SANITARY SEWER OR STORM SEWER FINISHED GRADE NOTE: (REFERENCE - "TEN STATE STANDARDS") WHEN INSTALLED PARALLEL, ALL WATER AND SEWER LINES SHALL HAVE A MINIMUM SEPARATION OF 10', EDGE TO EDGE. IF MINIMUM CANNOT BE MAINTAINED, WATER MAIN SHALL BE IN SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF TO ONE SIDE OF SEWER WITH BOTTOM OF WATER MAIN 18" MINIMUM ABOVE TOP OF SEWER PIPE. WHEN CROSSING, MAINS SHALL BE INSTALLED TO INSURE 18" MINIMUM VERTICAL SEPARATION BETWEEN PIPES, OUTSIDE TO OUTSIDE. WHERE WATER MAIN IS UNDERNEATH SEWER, ADEQUATE STRUCTURAL SUPPORT SHALL BE PROVIDED FOR THE SEWER TO PREVENT DAMAGE TO WATER MAIN. WHEN IT IS IMPOSSIBLE TO PROVIDE THE ABOVE MINIMUMS, THE SEWER SHALL BE DESIGNED AND CONSTRUCTED EQUAL TO WATER PIPE, AND SHALL BE PRESSURE TESTED TO ASSURE WATERTIGHT PRIOR TO BACKFILLING. 5' - 0 " M I N . 45 . 0 0 ° 5' - 0 " M I N . CORPORATION STOP WITH COMPRESSION FITTING, MUELLER H-15008 3/4" 8" D.I.P WATER MAIN CURB BOX; MUELLER 5'-6"± MODEL H-10314 (IN TURF) MODEL H-10334 (IN CONCRETE WALK) (SIZE AS REQUIRED FOR 3/4" OR 1" SERVICE) CURB STOP; MUELLER ORISEAL MODEL H-15209 COMPRESSION, MODEL H-15219 (W/DRAIN) (SIZE AS REQUIRED FOR 3/4" OR 1" SERVICE) SEE DETAIL FOR SPLICE TEMPORARY CAP OR PLUG AS NECESSARY 3/4" MIN, SIZE TYPE K COPPER PIPE SOLID CONC. BEARING BLOCK OR C.I. FOOT SEE NOTECURB ROADWAY 3/4" COPPER TUBING (TYPE K) NOTE: LOCATE CURB BOX BETWEEN CURB AND SIDEWALK AT CENTER OF TREE BELT. WHERE NO CURB/TREE BELT IS PRESENT INSTALL CURB BOX AT PROPERTY LINE. PROPERTY LINE Scale: NTS CONNECTION TO EXISTING SANITARY MAIN1 Scale: NTS UTILITY CROSSING2 Scale: NTS WATER SERVICE3 Scale: NTS DROP CURB AT RESIDENTIAL DRIVEWAY 4 ASPHALT DRIVEWAY CONCRETE SIDEWALK - TYPE 1 AT NON-VEHICLE TRAFFIC AREAS. TYPE 2 AT VEHICLE TRAFFIC AREAS. EXPANSION JOINT (FULL DEPTH OF PAVEMENT)TURF STREET 1-1/2" REVEAL ASPHALT APRONEXPANSION JOINT R5' TAPER CURB 6" CONCRETE CURB ASPHALT WARP AREA (BOTH SIDES) DROP S E C T I O N O F C U R B MIN. DR I V E W A Y W I D T H = 1 0 ' MAX.WIDTH = 2 5 % O F F R O N T A G E 5'-0" Planning Board # 20250518 Approval Approved under authority of a resolution adopted _____________________ by the Planning Board of the City of Saratoga Springs. Chairperson _________________________________________________ Date Signed:_________________________________________________ Unauthorized alteration or addition to this document is a violation of Section 7209 of the New York State Education Law. Jayco New Build, LLC 14 Dakota Drive Gansevoort, NY 12831 East Ave Subdivision East Ave Saratoga Springs NY, 12866 Project Title: Prepared for: Drawing Title Drawing No. Rev:Description:Date: Project No.: Design: Drawn: Date:Scale: Ch'k'd: © the LA Group 2017 2025025 SITE DETAILS C-4.1 DRC MLD DRC 6/12/2025 1"=20' 1 City Comments 08/27/25