Loading...
HomeMy WebLinkAbout20250687 266 Lake Ave Facade Change ApplicationRevised 01/2021 APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW APPLICANT(S)* OWNER(S) (If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person:  Applicant Owner Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises: Owner Lessee Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use:  Residential Non-residential/mixed-use Type of Review: Architectural Historic Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? No  Yes – date(s)? _____________________ -App. No.(s)? _________________ Date Acquired by Owner: _________________ **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION CITY HALL - 474 BROADWAY SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-springs.org [FOR OFFICE USE] _______________ (Application #) ____________ (Date received) __________________________ (Project Title) Staff Review _______________ **A “complete” application consists of 1 hard copy (original) , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions Color photographs showing site/exterior details of existing structures and adjacent properties A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) Color photographs showing site/exterior details of existing structures and that illustrate affected features Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) -Installation, removal or change in material of drive- and walkways -Installation or removal of architectural, sculptural or vegetative screening over 3’ in height -Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible Product literature, specifications and samples of proposed materials and colors Signage / Awnings Color photographs showing site/exterior details of existing structures, and adjacent properties Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location Product literature, specifications and samples of proposed materials and colors Demolition Color photographs showing site/exterior details of existing structures, and of adjacent properties Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale Written description of reasons for demolition and, in addition: For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities Color photographs showing site/existing structures, and of adjacent properties Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 01/2021 Revised 01/2021 Request for extension of current approval Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): -Construction or expansion of a multi-family residential structure (4 units +) -Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure -Telecommunications facility, radio antennae, satellite dishes -Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? No  Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Revised 01/2021 INSTRUCTIONS ARCHITECTURAL / HISTORIC REVIEW APPLICATION 1.ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2.COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3.ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District •any exterior changes that require a building permit •any change in exterior building materials •a new, or change to an existing, sign or sign structure •demolition of a structure Within a non-residential zoning district: •a change in exterior building color •installation of an awning •Installation or exterior change to a structure requiring a building or demolition permit •any material change to exterior of a structure including: -addition or removal of exterior architectural features -installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. -enclosure or screening or buildings openings such as windows, doors, porches, etc. -installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. Within a front yard setback: -installation, removal or material changes to drive- or walkways -installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height -installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter •a change in exterior building color within a non- residential zoning district •a new, or change to an existing, sign or awning •installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITY OF SARATOGA SPRINGS DESIGN REVIEW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x2533 www.saratoga-springs.org 4.DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: •Height – consistent with historic form and context of site and surrounding properties •Scale – relationship of structure and its architectural elements to human size, form, perception •Proportion – relationship among building elements including front façade, windows, and doors •Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements •Directional Expression – compatibility with horizontal & vertical expression of surrounding structures •Massing & Open Space – relationship of structure to open space between it and adjoining buildings •Setback – compatibility with surrounding structures •Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5.DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.AGENDA DATE: Check City’s website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7.APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance”. REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 6 266 Lake Ave – Paradee Backyard – to be replaced with Egress Window Backyard 266 Lake Ave – Paradee Side – Front Corner Side – Back Corner 266 Lake Ave – Paradee Front Prepared by: Jeff Stewart jstewart@adirondackbasement.com Adirondack Basement Systems, Inc www.AdirondackBasement.com TF 800-752-5807 O 518-371-9621 F 518-371-5888 Prepared on: 6-6-25 Prepared for: Adrienne Varney adriennevarney@gmail.com P (518) 321-4789 PR90339 Job location: 266 Lake Ave Saratoga Springs, NY 12866 Product List Egress Window, Large 1 Egress Window Well, Premier Medium 1 Egress Excavation, Equipment Excavation 1 Egress Cutting, Block 1 EverLast Basement Window 4 SunHouse, with Flat Lid 4 Remove Rim Joist Fiberglass Insulation 121 lnft Project Summary My Basement $7,945.00 Add Means of Egress $8,380.00 Total Investment $16,325.00 Total Contract Price $16,325.00 Deposit Required - 25%$4,081.25 Deposit Paid $4,081.25 Amount Due Upon Installation $12,243.75 Customer Consent Any alteration from the above specifications and corresponding price adjustment (if necessary) will be made only at the Customer’s request or approval. Completing the work in this Proposal at the time scheduled is contingent upon accidents or delays beyond our control. This Proposal is based primarily on the Customer’s description of the problem. This Proposal may be withdrawn if not accepted by the Customer within 30 days. Authorized Signature \s1\\d1\Date Acceptance of Contract— I am/we are aware of and agree to the contents of this Proposal, the attached Job Detail sheet(s), and the attached Limited Warranty, (together, the "Contract"). You are authorized to do the work as specified in the Contract. I/we understand the deposit is due at the time of signing the Contract and that a deposit marked as paid is only valid if the deposit was collected by you (the contractor), and the Contract has been signed by me/us (the customer) and you (the contractor). I/we will make the final payment set forth in this Contract at the time the project is completed. I/we will pay your service charge of 1-1/3% per month (16% per annum) if my/our account is 30 days or more past due, plus your attorney's fees and costs to collect and enforce this Contract. Customer Signature \s2\\d2\Date Customer has received a copy of the "Repair Science" book.Initial \i2\ Notice: A 3.5% fee applies when using a credit card for payment. Cash, check and Enerbank financing are accepted without this fee. Initial \i2\ Adirondack Basement Systems, Inc 80 Sheehan St. Mechanicville NY 12118 Job Location 266 Lake Ave Saratoga Springs NY 12866 Page 1/6 6-6-25 (4)6-6-25 (4) Job Details Type of Wall Block Existing Wall Finish Plain/Paneling/Sheetrock Existing Floor Finish Concrete/Tile Adirondack Basement Systems, Inc 80 Sheehan St. Mechanicville NY 12118 Job Location 266 Lake Ave Saratoga Springs NY 12866 Page 2/6 6-6-25 (4)6-6-25 (4) \i2\ Job Details (Continued) Specifications 1) Install a 48" x 48" vinyl window to meet local egress codes. 2) Install a 66" wide x 44" projection off the house and up to 60" deep Elite Series RockWell egress window well. 3) Using a mini excavator and a pick-up dump truck, excavate the surronding area needed to install the egress window and window well. The homeowner is aware there may be cosemetic damages to the lawn and/or landscaping and the homeowner understands they are responsible for repair/replacement. 4) Cut the block foundation after any necessary excavation, to allow for the installation of the egress window. 5) Install new vinyl EverLast Basement Window. (New window alone will not prevent window leakage.) 6) Install SunHouse Basement Window Enclosure. (Installation of SunHouse alone will not prevent window leakage.) 7) Remove and dispose the existing fiberglass rim joist insulation. Contractor Will 1.) Remove, dispose and replace concrete as necessary within the project area to allow for the proper installation of the system. Customer Will 1.) Ensure all personal items are moved at least 5 feet away from the work area, including items near the foundation and any center floor cracks. Additional Notes Customer has read and understands warranty. Customer agrees to pay all sales tax and municipal/permit fees required by the state and local building codes. Customer has read and understood the Customer/Contractor Will section. Customer Initial: ___________________ Customer has been recommended a TripleSafe and Full Perimeter waterproofing system. Customer has been made aware that flooding of the basement in the event of a power outage or mechanical failure of the single pump system is not under warranty and ABS is not responsible for any resulting damages. Customer approves location of Exterior Discharge line and if any future relocation after completed install will be additional cost of customer. Customer Initial: ___________________ Customer is aware EZ Posts include up to 7 feet of installation depth. If additional depth is required due to engineering specifications or soil conditions the customer agrees to pay an additional $300.00 for every 7' extension required to drive each EZ Post to the correct depth. If structural engineering provided by the customer mandates changes to the project scope, the customer understands and agrees that this will result in modifications to the project cost, irrespective of the current signed contract or earlier discussions. Customer Initial: ___________________ Piering Depth Clause: Average depth per pier included in this proposal: 35 feet. Each additional foot past the average: $42.00 per foot. Customer Initial: __________________ Customer will have the permit and required engineering before installation. Adirondack Basement Systems, Inc 80 Sheehan St. Mechanicville NY 12118 Job Location 266 Lake Ave Saratoga Springs NY 12866 Page 3/6 6-6-25 (4)6-6-25 (4) \i2\ Recommendations to Your Project Adirondack Basement Systems, Inc 80 Sheehan St. Mechanicville NY 12118 Job Location 266 Lake Ave Saratoga Springs NY 12866 Page 4/6 6-6-25 (4)6-6-25 (4) \i2\ Limited Warranty Standard Exclusions Permitted By State Law This Foundation Limited Warranty (“Warranty”) is made in lieu of and excludes all other warranties, express or implied, and all other obligations on the part of Adirondack Basement Systems (“Contractor”) to the customer (“Customer”). There are no other verbal or written warranties and no warranties that extend beyond the description on the face hereof, including NO WARRANTIES OF EXPRESS OR IMPLIED MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. General Terms For the applicable time periods indicated below, this Warranty is transferable at no charge to future owners of the structure on which the work specified in this Contract is completed. This Warranty is in effect if the job specified in this Contract is completed and paid in full and, alternatively, is null and void if full payment is not received. Contractor does not warrant products not mentioned below, but some of such products may be covered by a manufacturer’s warranty. All material used is warranted to be as specified in this Contract. All work will be completed in a workmanlike manner according to the standard practices of the industry. Exclusions THIS WARRANTY DOES NOT COVER, CONTRACTOR SPECIFICALLY DISCLAIMS LIABILITY FOR, AND CUSTOMER HOLDS CONTRACTOR HARMLESS FROM: 1) exterior waterproofing; 2) plumbing damage; 3) Customer-caused damage; 4) dust from installation; 5) damage to real or personal property such as walls, countertop, or floor coverings, framing, sheetrock, exterior materials, private utility lines, cabinets, appliances, and so on, including any damage alleged to have been done by the Contractor’s use of heavy equipment necessary to complete the job; 6) any injury or damage caused by mold to property or person; 7) failure or delay in performance or damage caused by acts of God (flood, fire, storm, methane gas, etc.), acts of civil or military authority, or any cause outside Contractor’s control; 8) damage from a lifting operation; 9) basement water seepage in areas not waterproofed by the Contractor; and 10) damage from heave, lateral movements/forces of hillside creep, land sliding, or slumping of fill soils. While Contractor assumes responsibility for utility damage that occurs as a result of Contractor’s installation, such protection is limited to replacing/repair the area Contractor damaged and does not include any upgrades to utilities for code compliance or other reasons.it also does not include any responsibility for damage done to the Customer’s private utility lines, including but not limited to gas lines for furnace/boilers, sprinkler lines, etc. Items For Which Customer Is Responsible Customer shall: 1) make full payment to the crew leader upon completion of work; 2) prepare the work area for installation; 3) be responsible for any finish carpentry, painting, paneling, landscaping, etc. that may be necessary after Contractor’s work is finished; 4) mark private lines (satellite, propane, sprinkler, etc.) 5) maintain positive drainage away from the repaired wall(s); 6) keep gutters clean and in good working order; 7) direct downspouts a sufficient distance away from the repaired wall(s); 8) maintain proper expansion joints in concrete slabs that are adjacent to the repaired wall(s); and 9) any items mentioned in this Contract under “Customer Will” or “Additional Notes.” Warranty Activation Warranty is in effect when job is completed and paid in full. Exclusions THIS WARRANTY DOES NOT COVER, AND THE CONTRACTOR SPECIFICALLY DISCLAIMS LIABILITY FOR WATER DAMAGE TO FLOOR COVERINGS, FURNITURE, STORED ITEMS, FINISHED WALLS AND OTHER OBJECTS INSIDE THE FOUNDATION. Contractor will not be responsible for any damages caused by mold, to include but not be limited to property damage, personal injury, loss of income, emotional distress, death, loss of use, loss of value, and adverse health effects, or any other effects. Homeowner agrees to keep area dry and report all other obligations on contractor’s part. There are no other warranties verbal or written. Adirondack Basement Systems, Inc 80 Sheehan St. Mechanicville NY 12118 Job Location 266 Lake Ave Saratoga Springs NY 12866 Page 5/6 6-6-25 (4)6-6-25 (4) \i2\ Notice of Right to Cancel You are entering into a contract. If that contract is a result of, or in connection with a salesman's direct contact with, or call to you at your residence without your soliciting the contract or call, then you have a legal right to void the contract or sale by notifying us within 14 business days from whichever of the following events occurs last: 1. The date of the transaction, which is: _________________________ or 2. The date you received this notice of cancellation. How to Cancel If you decide to cancel this transaction, you may do so by notifying us in writing at: Adirondack Basement Systems 4 Jones Rd Halfmoon, NY 12065 Adirondack Basement Systems, Inc TF 800-752-5807 O 518-371-9621 F 518-371-5888 www.AdirondackBasement.com 80 Sheehan St. Mechanicville, NY 12118 You may use any written statement that is signed and dated by you and states your intentions to cancel, or you may use this notice by dating and signing below. Keep one copy of the notice because it contains important information about your rights. I wish to cancel. Owner's Signature Date Owner's Signature Date The undersigned acknowledges receipt of the two copies of the Notice of Right to Cancel. Owner's Signature Date \s2\\d2\ Owner's Signature Date Adirondack Basement Systems, Inc 80 Sheehan St. Mechanicville NY 12118 Job Location 266 Lake Ave Saratoga Springs NY 12866 Page 6/6 6-6-25 (4)6-6-25 (4) \i2\ PRESCRIPTIVE METHOD SARATOGA COUNTY, NY ENERGY STATEMENT = PRESCRIPTIVE FOR CLIMATE ZONE 5A FENESTRATION MAXIMUM U-FACTOR = 0.30 CEILING INSULATION = MIN R-38 CONTINUOUS, R-49 WHERE APPLICABLE FLOOR INSULATION = R-30 OR INSULATION SUFFICIENT TO FILL FRAMING CAVITY (R-19 MIN) BASEMENT INSULATION = R-15 CONTINUOUS, R-19 CAVITY, OR R-13 CAVITY PLUS R-5 CONTINUOUS WALL INSULATION = R-20 CAVITY OR R-13 PLUS R-5 CONTINUOUS SLAB INSULATION = R-10 (2 FT DEPTH) CRAWL SPACE INSULATION = R-15 CONTINUOUS, R-19 CAVITY OR R-13 CAVITY PLUS R-5 CONTINUOUS RESIDENTIAL ENERGY STATEMENT TO THE BEST OF MY KNOWLEDGE, BELIEF, AND PROFESSIONAL JUDGEMENT THIS STRUCTURE MEETS OR EXCEEDS THE ENERGY REQUIREMENTS OF THE 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE AND CHAPTER 11 ENERGY EFFICIENCY OF THE 2020 RESIDENTIAL CODE OF NEW YORK STATE. EGRESS REQUIREMENTS: THE SILL HEIGHT SHALL NOT BE MORE THAN 44 INCHES ABOVE THE FLOOR. ALL BASEMENT AND GRADE FLOOR EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.0 SQ/FT. ALL OTHER EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQ/FT. THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES. THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES. THE MINIMUM HORIZONTAL AREA OF THE WINDOW WELL SHALL BE 9.0 SQ/FT WITH A MINIMUM HORIZONTAL PROJECTION AND WIDTH OF 36 INCHES. CONSTRUCTION TYPE: V DESIGN PROVISIONS...........2020 RESIDENTIAL CODE OF NEW YORK STATE & APPENDIX J 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE DESIGN LOADS: ROOF.....................................................................50 PSF (SNOW) 15 PSF (DEAD) ATTIC (W / STORAGE)...................................................................................20 PSF ATTIC (W/O STORAGE).................................................................................10 PSF CEILING.............................................................................................10 PSF (DEAD) FLOOR (SLEEPING).................................................30 PSF (LIVE) 12 PSF (DEAD) FLOOR (NON-SLEEPING)........................................40 PSF (LIVE) 12 PSF (DEAD) STAIRS...........................................................................................................40 PSF HANDRAILS.......................................................200 LBS (ANY POINT/DIRECTION) DECKS.................................................................................................40 PSF (LIVE) EXTERIOR BALCONY.........................................................................60 PSF (LIVE) CONCRETE DESIGN STANADARD.............................................................ACI 318 CONCRETE 28-DAY COMPRESSIVE STRENGTH, fc.............................3,000 PSI WIND LOADS: BASIC WIND SPEED (3 SECOND) GUST............................................................................................................115 MPH IMPORTANCE FACTOR (Iw)..........................................................................................................................1.0 HIGHEST POINT OF ROOF (FT)........................................................................................................................N/A TOPOGRAPHIC FACTOR (Kzt)........................................................................................................................1.0 VARNEY, ADRIENNE EGRESS WINDOW 266 LAKE AVE. SARATOGA SPRINGS, NY 12866 INDEX G001.........................................................................................COVER PAGE & GENERAL NOTES S100..........................................................................................................DEMO BASEMENT PLAN S200.................................................................................................PROPOSED BASEMENT PLAN ALL CONSTRUCTION SHALL CONFORM TO THE APPLICABLE STATE AND LOCAL BUILDING CODE REQUIREMENTS. DETAILS OF CONSTRUCTION UNLESS NOTED OTHERWISE SHALL BE PER THE 2020 NEW YORK STATE RESIDENTIAL CODE. CONTRACTOR SHALL PERFORM ALL MISCELLANEOUS REMOVALS, MODIFICATIONS, CONSTRUCTION AND CLEAN-UP REQUIRED TO COMPLETE THE GENERAL SCOPE OF THIS PROJECT. NO SITE INSPECTIONS DURING CONSTRUCTION ARE TO BE MADE BY THIS OFFICE. CONTRACTOR TO BE RESPONSIBLE FOR MATERIALS AND WORKMANSHIP. SUBSTITUTIONS FOR MATERIALS SPECIFIED TO BE MADE WITH PERMISSION OF LOCAL BUILDING DEPARTMENT. CONTRACTOR TO BE RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE BUILDING, ELECTRICAL, MECHANICAL, SANITARY AND ENERGY CONSERVATION CODES, STATE AND / OR LOCAL. CONTRACTOR TO BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES AND SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE CONTRACTOR / OWNER SHALL PERFORM EXPLORATORY EVALUATION TO DETERMINE ACTUAL FIELD CONDITIONS AND NOTIFY THE ENGINEER OF HIS FINDINGS TO ALLOW FOR DESIGN CHANGES PRIOR TO ACTUAL FOUNDATION AND CONSTRUCTION. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR / OWNER TO DEVELOP THE NECESSARY FOUNDATION SOIL TO SUSTAIN THE LOADS DESIGN OF 2 TONS PER SQ/FT AND TO HIRE A SOILS ENGINEER EXPERT TO INSPECT AND VERIFY SOIL CONDITIONS PRIOR TO POURING OF FOUNDATIONS. THE CONTRACTOR, BUILDER OR OWNER SHALL NOTIFY ENGINEER OF ANY UNUSUAL SITE CONDITIONS WHICH MAY EFFECT THE FOUNDATION, DRAINAGE OR STRUCTURAL MEMBERS INCLUDING REQUIREMENTS FOR ADDITIONAL DEPTH OF FOOTINGS, UNSTABLE SOIL CONDITIONS AND HIGH GROUND WATER TABLE. THE CONTRACTOR / OWNER SHALL REQUEST LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO ANY DIGGING. THE CONTRACTOR SHALL INDEMNIFY THE OWNER AND HIS AGENTS THROUGH ADEQUATE INSURANCE COVERAGE AGAINST ANY CLAIMS ARISING FROM INJURIES DURING CONSTRUCTION, OR FAILURE TO MAINTAIN SAFE CONDITIONS ON THE CONSTRUCTION SITE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, OWNER OR BUILDER OF THIS STRUCTURE TO NOTIFY THE ENGINEER OF ANY DEVIATION FROM THESE DRAWINGS. THESE PLANS COMPLY WITH ALL THE CODES, PROVISIONS AND INTENT OF THE NEW YORK STATE ENERGY CONSERVATION CONSTRUCTION CODE PURSUANT TO ARTICLE 2 OF THE ENERGY LAW. LOCAL CODE REQUIREMENTS SHALL TAKE PRECEDENCE WHERE DISCREPANCIES OCCUR. ANY ERRORS, OMISSIONS OR DISCREPANCIES IN THESE PLANS SHALL BE REPORTED IN WRITING TO THE ENGINEER BEFORE START OF CONSTRUCTION AND SHALL BE THE SOLE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. UNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. GENERAL NOTES: DESIGNED IN ACCORDANCE WITH THE 2020 NEW YORK STATE RESIDENTIAL CODE AND APPENDIX J. DIMENSIONS TO, OF, AND IN EXISTING STRUCTURE (IF APPLICABLE) SHALL BE VERIFIED IN FIELD BY CONTRACTOR. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES IN DIMENSIONS BETWEEN EXISTING CONDITIONS AND / OR ARCHITECTURAL DRAWINGS AND THE STRUCTURAL DRAWINGS. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. DETAILS SHOWN ARE TYPICAL, SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. DIMENSION AND NOTES THAT INCLUDE THE WORD "TYPICAL" REFER TO ALL SIMILAR DETAILS UNLESS OTHERWISE STATED. THE NOTES ON THIS DRAWING ARE TYPICAL UNLESS NOTED OTHERWISE. BRACE BUILDING UNTIL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: ROOF DECK, CONNECTION TO EXISTING BUILDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ADEQUATE SHORING AND BRACING DURING CONSTRUCTION AND COMPLY WITH ALL APPLICABLE SAFETY REGULATIONS. CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF PROPOSED DEVIATIONS OR SUBSTITUTIONS FROM DIMENSIONS, MATERIALS, OR EQUIPMENT SHOWN ON THE DRAWINGS AND MAKE ONLY THOSE DEVIATIONS OR SUBSTITUTIONS ACCEPTED BY THE ENGINEER. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY. ALL PLUMBING, HVAC, ELECTRICAL, AND FIRE SYSTEMS ARE BY OTHERS. LOCATIONS, DESIGN AND INSTALLATION OF ALL NOTED ABOVE ARE TO BE COMPLETED BY LICENSED INDIVIDUALS ACCORDING TO ALL BUILDING CODE AND THE MANUFACTURERS PRODUCT INSTALLATION INSTRUCTION. ALL DOORS AND WINDOWS TO BE INSTALLED ACCORDING TO THE MANUFACTURERS PRODUCT INSTALLATION INSTRUCTION. FRAMING NOTES: 1. STRUCTURAL FRAMING MEMBERS SHALL BE SPF #2 OR BETTER UNLESS NOTED OTHERWISE. 2. FLOOR SHEATHING SHALL BE GLUED AND NAILED TO FLOOR JOISTS ACCORDING TO NAILING SCHEDULE. ROOF AND WALL SHEATHING SHALL BE NAILED ACCORDING TO NAILING SCHEDULE. 3. SILL PLATES SHALL BE PRESSURE TREATED WOOD OR WOOD OF NATURAL RESISTANCE TO DECAY. 4. FRAMING MEMBERS SHALL NOT BE CUT OR NOTCHED IN EXCESS TO: BEARING WALL OR NON BEARING WALL MEMBERS:IRC R602.6. FLOOR MEMBERS: IRC R502.8 5. PROVIDE SOLID BLOCKING FOR FLOOR JOISTS UNDER ALL INTERMEDIATE BEARING WALLS AND AT ENDS BY FULL DEPTH BLOCKING, PROVIDE BLOCKING EVERY 8' MAX. OF FLOOR JOIST SPAN. 6. TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR TRUSS DESIGN AND ALL STATED DESIGN LOADS. 7. ENGINEERED WOOD PRODUCTS TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 8. ALL WOOD INCLUDING POSTS LOCATED NEARER THAN 18" (12" FOR GIRDERS) TO EARTH OR LOCATED ON CONCRETE PLACED ON EARTH SHALL BE PRESSURE TREATED OR WOOD OF NATURAL RESISTANCE TO DECAY. 9. HEADERS ARE TO BE BUILT UP (PER CODE) IN FRAMED WALLS U.N.O.-SUPPORT EACH HEADER W/ DOUBLE TRIMMER STUDS WHERE OPENINGS ARE 48" WIDE OR GREATER. 10. FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL). FIRE BLOCKING SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS: A) IN CONCEALED SPACES OF STUD WALLS, INCLUDING FURRED SPACES, AT CEILING AND FLOOR LEVELS. CONCEALED HORIZONTAL FURRED SPACES SHALL ALSO BE FIRE BLOCKED AT INTERVALS NOT TO EXCEED 10 FT. BATTS OR BLANKETS OF MINERAL OR GLASS FIBER SHALL BE ALLOWED AS FIRE BLOCKING. B) AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS. C) IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. D) AT OPENINGS AROUND VENTS, PIPES, AND DUCTS AT CEILING AND FLOOR LEVEL, TO RESIST FIRE PASSAGE OF FLAME AND PRODUCTS OR COMBUSTION. E) FIRE BLOCKING OF CORNICES OR A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING UNIT SEPARATION. 11. JOISTS EXCEEDING A NOMINAL 2 X 12 SHALL BE SUPPORTED LATERALLY BY SOLID BLOCKING, DIAGONAL BRIDGING, OR A CONTINUOUS 1 X 3 STRIP NAILED ACROSS THE BOTTOM OF JOISTS PERPENDICULAR TO JOISTS AT INTERVALS NOT EXCEEDING 8 FT. 12. PROVIDE FULL BEARING SUPPORT FOR ALL BEAMS (EX. 4X BEAMS SUPPORTED BY (2) 2X OR 4X POSTS, 6X/8X BEAMS SUPPORTED BY 6X/8X POST, ETC). 13. HARDWARE IS TO BE "SIMPSON STRONG-TIE" OR EQUAL. TOP PLATE TO STUD (END NAIL)..............................2-16D COMMON STUD TO SOLE PLATE (END NAIL)............................2-16D COMMON STUD TO SOLE PLATE (TOE NAIL)............................4-8D COMMON OR 3-16D BOX DOUBLE TOP PLATES................................................10D BOX @ 12" OC DBL TOP PLATE LAP SPLICE......................................8-16D COMMON TOP PLATES LAPS (INTERSECTION)........................3-10D BOX SOLE PLATE TO JOISTS OR BLOCKING...................16D COMMON @ 16" OC CEILING JOISTS TO TOP PLATE (TOE-NAIL)............3-8D COMMON CEILING JOISTS OVER PARTITION...........................4-10D BOX CEILING JOISTS TO PARALLEL RAFTER..................PER R802.5.1(9) RAFTER TO TOP PLATE (TOE-NAIL)..........................3-16D BOX 1X BRACE TO STUD/PLATE........................................2-8D COMMON JOISTS TO SILL PLATE (TOE-NAIL)...........................3-8D COMMON RAFTER TO RIDGE, HIP OR VALLEY (TOE-NAIL).....4-16D BOX RAFTER TO RIDGE, HIP OR VALLEY (END-NAIL).....3-16D BOX RAFTER-TIES TO RAFTER..........................................4-8D BOX SUBFLOOR TO FLOOR JOISTS..................................6D COMMON @ 6" OC EDGE 12" OC FIELD WALL SHEATHING TO STUD......................................6D COMMON @ 6" OC EDGE 12" OC FIELD ROOF SHEATHING TO RAFTER/TRUSS....................8D COMMON @ 6" OC EDGE 12" OC FIELD NAILING SCHEDULE: PER R602.3(1) WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E ED U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D PR O F E S S I O N A L , T O A L T E R I N A N Y WA Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R RE P O R T S T O W H I C H T H E S E A L O F P R O F E S S I O N A L EN G I N E E R H A S B E E N A P P L I E D . STAMP: SHEET: PAPER SIZE: C (18"x24") SCALE: FILE: PAGE CONTENT: ENGINEER:DESIGNER: DA T E : START DATE: DATE: RE C O R D O F W O R K : DE S C R I P T I O N : BY : EXPIRES 5/31/2027 NONE VA R N E Y , A D R I E N N E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 26 6 L A K E A V E . EG R E S S W I N D O W 07/15/2025 GENERAL NOTES COVER SHEET & NOLANHART G001 DEMO BASEMENT PLAN SCALE: 1 4" = 1'-0" 1 S100 N 45'-4" 23'-11" 33'-9"5'-2" 11'-7" EXISTING BEAM EXISTING BEAM EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXIST. 2X10 JOISTS @ 16" O.C. EXIST. 2X10 JOISTS @ 16" O.C. 11'-63 4" 12'-41 4" CLG. HGT: 82" TO BOTTOM OFJOIST HOPPER WINDOW TO BE REMOVED. DEMO PORTION OF WALL TO ALLOW FOR NEW EGRESS WINDOW INSTALLATION +/-4'-3" R.O. EXISTING WINDOW TO REMAIN WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E ED U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D PR O F E S S I O N A L , T O A L T E R I N A N Y WA Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R RE P O R T S T O W H I C H T H E S E A L O F P R O F E S S I O N A L EN G I N E E R H A S B E E N A P P L I E D . STAMP: SHEET: PAPER SIZE: C (18"x24") SCALE: FILE: PAGE CONTENT: ENGINEER:DESIGNER: DA T E : START DATE: DATE: RE C O R D O F W O R K : DE S C R I P T I O N : BY : EXPIRES 5/31/2027 NONE VA R N E Y , A D R I E N N E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 26 6 L A K E A V E . EG R E S S W I N D O W 07/15/2025 DEMO BASEMENT PLAN NOLANHART S100 PROPOSED BASEMENT PLAN SCALE: 1 4" = 1'-0" 1 S200 N EXISTING BEAM EXISTING BEAM EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXIST. 2X10 JOISTS @ 16" O.C. CLG. HGT: 82" TO BOTTOM OFJOIST PROVIDE NEW EGRESS WINDOW PER OWNER. PROVIDE (2) P.T. 2X8 HEADER ON (2) 2X TRIMMERS. ENSURE CODE MIN. EGRESS REQUIREMENTS ARE MET, REFER TO G001. PROVIDE NEW WINDOW WELL PER CODE (3'X3' MIN AREA, REFER TO G001.) PROVIDE 4x4x 3 16 ANGLE LINTEL FOR BRICK W/ 3" MIN. END BEARING EXISTING WINDOW TO REMAIN WA R N I N G : IT I S A V I O L A T I O N O F N E W Y O R K S T A T E ED U C A T I O N L A W F O R A N Y P E R S O N , U N L E S S AC T I N G U N D E R T H E D I R E C T I O N O F A L I C E N S E D PR O F E S S I O N A L , T O A L T E R I N A N Y WA Y A N Y P L A N S , S P E C I F I C A T I O N S , P L O T S O R RE P O R T S T O W H I C H T H E S E A L O F P R O F E S S I O N A L EN G I N E E R H A S B E E N A P P L I E D . STAMP: SHEET: PAPER SIZE: C (18"x24") SCALE: FILE: PAGE CONTENT: ENGINEER:DESIGNER: DA T E : START DATE: DATE: RE C O R D O F W O R K : DE S C R I P T I O N : BY : EXPIRES 5/31/2027 NONE VA R N E Y , A D R I E N N E SA R A T O G A S P R I N G S , N Y 1 2 8 6 6 26 6 L A K E A V E . EG R E S S W I N D O W 07/15/2025 PLAN PROPOSED BASEMENT NOLANHART S200