HomeMy WebLinkAbout20250553 54 Ash St. Exterior Modifications - Solar Array NOD
Page 1 of 1
Tamie Ehinger, Chair
Rob DuBoff, Vice Chair
Chris Bennett
Leslie DiCarlo
Jeff Gritsavage
Geoff Wood
Karen Cavotta, Alternate
CITY OF SARATOGA SPRINGS
D ESIGN R EVIEW B OARD
❖
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x.2517
www.saratoga-springs.org
NOTICE OF DECISION
In the matter of the application
#20250553
54 Ash St. Exterior Modifications – Solar Array
54 Ash St.
Saratoga Springs, New York 12866
involving Architectural review of a roof mounted solar array panel in the Arts and Culture (AC) District, tax parcel # 165.74-2-56,
within the City of Saratoga Springs.
In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:
Type II action – exempt from further SEQR review
And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240 -
13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on July
16, 2025:
Approve the project as submitted with the following conditions:
Applicant to submit equipment and conduit placement for final Administrative approval; conduit must be
paintable to match structure.
Record of vote:
motion to approve made by J Gritsavage, seconded by G Wood: passed 6-0
In favor: TEhinger, LDiCarlo, RDuBoff, JGritsavage, K Cavotta, G Wood
As a result of this decision, the applicant:
may proceed with the proposed project as approved
Please contact the Building Department to verify permit requirements.
Chair Received by Accounts
cc: Building Department
Accounts Dept.
Applicant/Agent
PHOTOVOLTAIC SYSTEM
AERIAL VIEW
APPLICABLE CODE PER LOCAL AUTHORITY HAVING
JURISDICTION
APPLICABLE CODES
INDEX GENERAL NOTES PV1
VICINITY MAP
JENNY WHITENECK: 54 ASH ST, SARATOGA SPRINGS, NY 12866, USA
N
43.077229, -73.792769
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
CO
V
E
R
P
A
G
E
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
2017 NATIONAL ELECTRICAL CODE
2020 FIRE CODE OF NYS
2020 RESIDENTIAL CODE OF NYS
2020 BUILDING CODE OF NYS GENERAL NOTES:
1.DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS
SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR
STANDARDIZED.
2.ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS.
3.IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES,
OVER-CURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND
MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND
INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST
CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE
COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND
SAFETY OF THE OPERABLE SYSTEM.
4.ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED.
5.METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT
CIRCUITS ARE RUN INSIDE A BUILDING.
6.MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6"
ABOVE FLUSH VENTS.
7.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS
GIVEN BY UTILITY COMPANIES.
8.FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS.
9.ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY
NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS
BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE
INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14
C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10.
10.ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC
REFERENCES.
STRUCTURAL NOTES:
1.MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE
ACCURATELY SPACED.
2.MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD
AMONGST RAFTERS.
3.DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS.
ELECTRICAL NOTES:
1.ALL EQUIPMENT IS LISTED FOR USE.
2.MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC.
3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION
SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING
LABORATORY.
4.AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY
DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND
DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL
REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION
NETWORK VOLTAGE HAS BEEN RESTORED.
5.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION.
6.ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT
CALCULATED AT THAT COMPONENT.
7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL
BE PROPERLY GROUNDED.
8.DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM.
9.MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE
DISCONNECT EQUIPMENT MIGHT BE ENERGIZED.
10.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL
BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE
JURISDICTIONAL REQUIREMENTS.
11.FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL
SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION
BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED,
UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE.
12.INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION
DEVICE.
13.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND
ELECTRICALLY CONTINUOUS.
14.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC.
15.BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF
THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER.
16.ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO
TEMPERATURE DERATING AND LOCATION.
17.ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE
STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS.
18.DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED.
19.ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS.
20.ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE
NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL.
PV1
PV2
PV3
PV4
PV5
PV6 - 6.1
COVER PAGE
SITE PLAN
MOUNTING PLAN
MOUNTING DETAILS
ELECTRICAL DIAGRAMS
MARKING & LABELS
ATTACHMENTS
MANUFACTURER'S SPECIFICATIONS
PV7
STRUCTURAL DETAILS
SYSTEM SIZE:
NAMEPLATE:
EQUIPMENT:
PV MODULES:
AC COMPONENT(S):
SCOPE OF WORK:
INSTALLATION OF A CODE COMPLIANT, UTILITY INTERACTIVE
PHOTOVOLTAIC ELECTRIC SYSTEM.
11.05 KW DC / 7.54 KW AC
MICROINVERTER:(26) ENPHASE IQ8PLUS-72-M-US MICROINVERTERS
26) JINKO SOLAR JKM425N-54HL4-B (425 W) SOLAR MODULES
TYPE OF INTERCONNECTION:LINE SIDE TAP IN THE MSP
1) 60A FUSED AC DISCONNECT
1) 125A ENPHASE IQ COMBINER PANEL 5/5C
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
3
3
3
3
1'-6"
E) UTILITY METER
OUTSIDE HOUSE)
E)MAIN SERVICE PANEL
INSIDE HOUSE)
N) AC DISCONNECT
FUSED)(OUTSIDE HOUSE)
N) COMBINER PANEL
OUTSIDE HOUSE)
P
R
O
P
E
R
T
Y
L
I
N
E
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LIN E
P
R
O
P
E
R
T
Y
L
I
N
E
P
R
O
P
E
R
T
Y
L
I
N
E
4'-8"
8
5
3
3
1
0
4'-2"
MP1
MP2
DRIVE WAY
W
A
L
K
W
A
Y
ASH ST
3
3
B
E
E
K
M
A
N
S
T
PROPERTY LIN E
P
R
O
P
E
R
T
Y
L
I
N
E
1'-6"
N
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
SI
T
E
P
L
A
N
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
ARRAY 1
TILT: 42°
AZIMUTH: 83°
ARRAY SPECIFICATIONS
ARRAY 2
TILT: 42°
AZIMUTH: 83°
UTILITY METER
AC DISCONNECT FUSED
MAIN SERVICE PANEL
3' WIDE FIRE ACCESS PATHWAY
18'' VENTILATION SETBACK
3'x3' GROUND LADDER ACCESS POINT
LEGEND
COMBINER PANEL
PV2
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
18'
8'
1
0
43'
16
17'-7"
1'-8"
23'-9"
MP1
TILT:42°
AZIMUTH: 83°
MP2
TILT:42°
AZIMUTH: 83°
3' WIDE FIRE ACCESS
PATHWAY
18'' VENTILATION SETBACK
SOLAR MODULE
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
MO
U
N
T
I
N
G
P
L
A
N
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
TYPE
MODULE
MICROINVERTER
DESCRIPTION QUANTITY
26
26
1
JINKO SOLAR JKM425N-54HL4-B (425 W) SOLAR
MODULES
ENPHASE IQ8PLUS-72-M-US MICROINVERTER
60A FUSED ACDISCONNECTDISCONNECT 1
125A ENPHASE IQ COMBINER PANEL 5/5CCOMBINER
ROOF SPECIFICATION
ROOF MATERIAL
ROOF CONDITION GOOD
RAFTERS
ASPHALT SHINGLE
2" X 6" @ 24" O.C.
PV3
Applicable Codes:
Ground Snow Load:
Basic Wind Speed:
Existing Roof Dead Load:
Existing Roof Live Load:
2020 Residential Code of NYS, ASCE 7-16 and NDS-18
50 lb/sqft
109 mph, Exposure Category B
7 lb/sqft
20.00 lb/sqft
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
PZSE advises that best
practice in snow load areas is
to install staggered
attachments”
14 RD STRUCTURAL SCREW MIN. EMBED.
2.5" INTO ROOF FRAMING PER
ATTACHMENT
IRONRIDGE (XR10) RAILS
IRONRIDGE
QUICK MOUNT
HALO ULTRAGRIP)
IRONRIDGE (QUICKMOUNT HALO ULTRAGRIP)
IRONRIDGE (XR10) RAILS
SOLAR MODULE
WOOD SHEATHING
WOOD ROOF
RAFTER TYP.
WOOD ROOF
RAFTER TYP.
WOOD SHEATHING
RELEASE LINER
RELEASE LINER
STRUCTURAL ATTACHMENT DETAILS
SOLAR MODULES
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
ST
R
U
C
T
U
R
A
L
D
E
T
A
I
L
S
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
PV4
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
MO
U
N
T
I
N
G
D
E
T
A
I
L
S
PV5
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
MODULES
26) JINKO SOLAR JKM425N-54HL4-B (425W)
SOLAR MODULES
WATTS STC: 425W
ISC: 13.58A
IMP: 13.13A
VOC: 38.95V
VMP: 32.37V
CONDUCTORS AND CONDUIT
41
2
1) #6 THHN GND
3/4" EMT
1) #6 THHN GND
3/4"EMT
3 (
3) #6 THHN
3/4"EMT
2) ENPHASE Q CABLES
4)#10 THHN
1) #6 THHN GND
3) #6 THHN
3/4"EMT
1) #6 THHN GND
INVERTER(S)
26)ENPHASE IQ8PLUS-72-M-US
MICROINVERTER
INV OUTPUT CURRENT: 1.21 A
MAX AC OUTPUT: 26X1.21 = 31.46 A
INVERTER OCPD CALC :(31.46) X 1.25 =
39.325A
MIN OCPD: 40A
WIRE AMPACITY: 65A @75° C TERMINAL
TEMPERATURE CORRECTION FACTOR:
31°-35°C = 0.96
CORRECTED WIRE AMPACITY: 62.40A
OTHER EQUIPMENT
1) 60A FUSED AC DISCONNECT
1) 125A ENPHASE IQ COMBINER PANEL 5/5C
G
N) JUNCTION
BOX
ENVOY IQ
G
1 STRING OF
13 MODULES WITH
MICROINVERTERS
1 STRING OF
13 MODULES WITH
MICROINVERTERS
1 2
15A/2P
20A/2P
20A/2P
N
N) 125A ENPHASE IQ
COMBINER PANEL 5/5C
OUTSIDE HOUSE)
120/240V
PANEL
MAIN SERVICE
FUSED
DISCONNECT
N) 60A AC
G
3 4
N) 40A/2P
E) 200
UM
NG
E) 200A
GEC
N
A
OUTSIDE HOUSE)
INSIDE HOUSE)
OUTSIDE HOUSE)
E) UTILITY METER
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
EL
E
C
T
R
I
C
A
L
D
I
A
G
R
A
M
S
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
PV6
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
STRUCTURAL ONLY
MODULES
26) JINKO SOLAR JKM425N-54HL4-B (425W)
SOLAR MODULES
WATTS STC: 425W
ISC: 13.58A
IMP: 13.13A
VOC: 38.95V
VMP: 32.37V
CONDUCTORS AND CONDUIT
41
2
1) #6 THHN GND
3/4" EMT
1) #6 THHN GND
3/4"EMT
3 (
3) #6 THHN
3/4"EMT
2) ENPHASE Q CABLES
4)#10 THHN
1) #6 THHN GND
3) #6 THHN
3/4"EMT
1) #6 THHN GND
INVERTER(S)
26)ENPHASE IQ8PLUS-72-M-US
MICROINVERTER
INV OUTPUT CURRENT: 1.21 A
MAX AC OUTPUT: 26X1.21 = 31.46 A
INVERTER OCPD CALC :(31.46) X 1.25 =
39.325A
MIN OCPD: 40A
WIRE AMPACITY: 65A @75° C TERMINAL
TEMPERATURE CORRECTION FACTOR:
31°-35°C = 0.96
CORRECTED WIRE AMPACITY: 62.40A
OTHER EQUIPMENT
1) 60A FUSED AC DISCONNECT
1) 125A ENPHASE IQ COMBINER PANEL 5/5C
G
N) JUNCTION
BOX
1 STRING OF
13 MODULES WITH
MICROINVERTERS
1 STRING OF
13 MODULES WITH
MICROINVERTERS
1 2
G
ENVOY IQ
15A/2P
20A/2P
20A/2P
N
N) 125A ENPHASE IQ
COMBINER PANEL 5/5C
OUTSIDE HOUSE)
G
3
4
N) 40A/2P
G N
UMN
GEC
FUSED
DISCONNECT
N) 60A AC
OUTSIDE HOUSE)
120/240V
PANEL
MAIN SERVICE
E) 200 A
INSIDE HOUSE)
OUTSIDE HOUSE)
E) UTILITY METER
E) 200A
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
EL
E
C
T
R
I
C
A
L
D
I
A
G
R
A
M
S
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
PV6.1
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
PROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
STRUCTURAL ONLY
CO
N
T
R
A
C
T
O
R
PL
U
G
P
V
L
L
C
SY
S
T
E
M
DC
K
W
1
1
0
5
AC
K
W
7
5
4
MO
D
U
L
E
S
2
6
JE
N
N
Y
W
H
I
T
E
N
E
C
K
54
A
S
H
S
T
S
A
R
A
T
O
G
A
S
P
R
I
N
G
S
NY
1
2
8
6
6
U
S
A
CO
N
T
R
A
C
T
O
R
S
L
I
C
E
N
S
E
8
2
0
6
7
4
7
5
8
DATE
05/01/2025
DESIGNED BY:
OMA
MA
R
K
I
N
G
L
A
B
E
L
S
63
0
7
T
H
A
V
E
T
R
O
Y
N
Y
1
2
1
8
2
U
S
A
INVERTER AC DISCONNECT
NEC 690.14(C)(2)
PHOTOVOLTAIC
SYSTEM EQUIPPED WITH
RAPID SHUTDOWN
CONDUIT, RACEWAYS,
ENCLOSURES, CABLE
ASSEMBLIES
JUNCTION BOXES
Warning: Photovoltaic Power Source
NEC 690.35(F) UNGROUNDED SYSTEMS JUNCTION BOX
WARNING
ELECTRIC SHOCK HAZARD.
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE
ENERGIZED.
PHOTOVOLTAIC DISCONNECT
FOR UTILITY OPERATIONS
NEC 705.12(D)(7)
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED
BREAKER. IF INSTALLED ANYWHERE ELSE ON DEADFRONT
THEN A PERMANENT ARROW FROM LABEL POINTING TO
PV BACKFEED BREAKER REQUIRED.
MAIN SERVICE PANEL
WARNING
ELECTRIC SHOCK HAZARD.
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION.
WARNING
NEC 705.12(D)(4)), 690.56(B)
POWER IS BEING SUPPLIED TO THIS
PANEL FROM THE UTILITY AND A
SOLAR PV SYSTEM.
NEC 690.54
RATED AC OUTPUT CURRENT: _____ A31.46
NOMINAL AC VOLTAGE: _____ V240
NEC 690.14(C)(2)
PHOTOVOLTAIC AC DISCONNECT
NEC 690.54
RATED AC OUTPUT CURRENT: _____ A
240
31.46
NOMINAL AC VOLTAGE: _____ V
NEC 690.52
PHOTOVOLTAIC ARRAY DC DISCONNECT
NOMINAL OPERATING AC VOLTAGE: 240 V
NOMINAL OPERATING AC FREQUENCY: 60HZ
MAX. AC POWER: 290 VA
MAX AC CURRENT: 1.21 A
MAX OVERCURRENT DEVICE RATING FOR AC
MODULE PROTECTION PER CIRCUIT:20A
NEC 690.13(4)
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE
OFF" POSITION ONLY
CONDUCTORS INSIDE
BUILDING OR OFF THE
ROOF WILL SHUT DOWN
EMERGENCY RESPONDER
THIS SOLAR PV SYSTEM
EQUIPPED
WITH RAPID SHUTDOWN
NEC 690.56
NEC 690.31(D)(2) CONDUIT
PV7
54 ASH ST, SARATOGA
SPRINGS, NY 12866
EXP. 07/31/2027
LI
C
E
N
S
E
D
P
ROFESS I O N A L E NGINEER
P A U L K .ZAC
H
E
R
STRUCTURAL ONLY