HomeMy WebLinkAbout20250520 198 S Broadway Exterior Modification Owner's Manual and Installation ManualSPLIT-TYPE ROOM AIR CONDITIONER
Owner’s Manual &
Installation Manual
IMPORTANT NOTE:
Read this manual and SAFETY MANUAL(if any)
carefully before installing or operating your new
air conditioning unit. Make sure to save this
manual for future reference.
Please check the applicable models, technical
data, F-GAS(if any) and manufacturer information
from the “Owner's Manual - Product Fiche ”
in the packaging of the outdoor unit (European Union
products only) or in the packaging of the indoor unit
(model dependent)
SENA/09HF/IQ
SENA/09HF/OQ
SENA/12HF/IQ
SENA/12HF/OQ
SENA/18HF/IQ
SENA/18HF/OQ
SENA/24HF/IQ
SENA/24HF/OQ
Unit Specifications and Features...........................................................07
Owner’s Manual
Table of Contents
Safety Precautions ...............................................................................04
Care and Maintenance ............................. .........................................11
Troubleshooting.................................................................................13
1. Indoor unit display..........................................................................................................................07
2. Operating temperature...................................................................................................................08
3. Other features ...............................................................................................................................09
4. Setting angle of airflow..................................................................................................................10
5. Manual operation (without Remote)...............................................................................................10
Installation Manual
Accessories ...................... .....................................................................17
Unit Parts..............................................................................................19
Indoor Unit Installation .......................................................................20
1.Select installation location...........................................................................................................20
2.Attach mounting plate to wall....................................................................................................20
3.Drill wall hole for connective piping...........................................................................................20
4. Prepare r efrigerant piping................................................................................................................22
5.Connect drain hose.......................................................................................................................24
6.Connect signal and power cables................................................................................................25
7. W rap piping and cables...................................................................................................................26
8. Mount indoor unit........................... ...................................................................................................27
Outdoor Unit Installation.........................................................................28
1. Select installation location...............................................................................................................28
2. Install drain joint.............................................................................................................................29
3. Anchor outdoor unit.......................................................................................................................29
4. Connect signal and power cables....................................................................................................30
Refriger ant Piping Connection.........................................................32
A. Note on Pipe Length.....................................................................................................................32
B. Connection Instructions –Refrigerant Piping..................................................................................32
1. Cut pipe..................................................................................................................................32
2. Remove burrs..........................................................................................................................33
3. Flar e pipe ends........................................................................................................................33
4. Connect pipes.........................................................................................................................33
Air Evacuation...................................................................................35
1. Evacuation Instructions.................................................................................................................35
2. Refrigerant Release.......................................................................................................................35
Electrical and Gas Leak Checks........................................................37
Packing and unpacking the unit .....................................................39
T est Run.............................................................................................38
Installation Summary - Indoor Unit ..................................................18
3. Note on Adding Refrigerant..........................................................................................................36
Page 4
Sa
f
e
t
y
Pr
e
c
a
u
t
i
o
n
s
Read Safety Precautions Before Operation and Installation
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
Incorrect installation due to ignoring instructions can cause serious damage or injury.
WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced
This appliance is not intended for use by persons(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance.
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision European Union countries
.
WARNINGS FOR PRODUCT USE
•If an abnormal situation arises (like a burning smell), immediately turn off the unit and disconnect
the power. Call your dealer for instructions to avoid electric shock, fire or injury.
•Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since
the fan may be rotating at high speeds.
•Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause
fire or combustion.
•Do not operate the air conditioner in places near or around combustible gases. Emitted gas may
collect around the unit and cause explosion.
•Do not
•
•
Do not expose your body directly to cool air for a prolonged period of time.
•
•
If the air conditioner is used together with burners or other heating devices, thoroughly ventilate
the room to avoid oxygen deficiency.
Safety Precautions
Do not allow children to play with the air conditioner. Children must be supervised around the
unit at all times.
operate your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
In certain functional environments, such as kitchens, server rooms, etc., the use of specially
designed air-conditioning units is highly recommended.
•Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning agents
can cause fire or deformation.
CLEANING AND MAINTENANCE WARNINGS
•Turn off the device and disconnect the power before cleaning. Failure to do so can causeelectrical shock.
•Do not clean the air conditioner with excessive amounts of water.
WARNING
This symbol indicates the possibility
of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of
property damage or serious consequences.
Page 5
Sa
f
e
t
y
Pr
e
c
a
u
t
i
o
n
s
CAUTION
•Turn off the air conditioner and disconnect the power if you are not going to use it for a long time.
•Turn off and unplug the unit during storms.
•Make sure that water condensation can drain unhindered from the unit.
•Do not operate the air conditioner with wet hands. This may cause electric shock.
•Do not use device for any other purpose than its intended use.
•Do not climb onto or place objects on top of the outdoor unit.
•Do not allow the air conditioner to operate for long periods of time with doors or windows open,
or if the humidity is very high.
ELECTRICAL WARNINGS
•Only use the specified power cord. If the power cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
•Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty
plugs can cause fire or electric shock.
•
•
•
•
•
•
•
Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling
directly on the cord can damage it, which can lead to fire or electric shock.
Do not modify the length of the power supply cord or use an extension cord to power the unit.
Do not share the electrical outlet with other appliances. Improper or insufficient power supply
can cause fire or electrical shock.
If connecting power to fixed wiring, an all-pole disconnection device which has at least 3mm
clearances in all poles, and have a leakage current that may exceed 10mA, the residual current
device(RCD) having a rated residual operating current not exceeding 30mA, and disconnection
must be incorporated in the fixed wiring in accordance with the wiring rules.
For all electrical work, follow all local and national wiring standards, regulations, and the
Installation Manual. Connect cables tightly, and clamp them securely to prevent external forces
from damaging the terminal. Improper electrical connections can overheat and cause fire, and may
also cause shock. All electrical connections must be made according to the Electrical Connection
Diagram located on the panels of the indoor and outdoor units.
All wiring must be properly arranged to ensure that the control board cover can close properly. If
the control board cover is not closed properly, it can lead to corrosion and cause the connection
points on the terminal to heat up, catch fire, or cause electrical shock.
The product must be properly grounded at the time of installation, or electrical shock may occur.
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection.
The specifications of the fuse are printed on the circuit board ,such as :
T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC,etc.
NOTE: For the units using R32 or R290 refrigerant , only the blast-proof ceramic fuse can be used.
UV-C lamp(Applicable to the unit contains an UV-C lamp only)
This appliance contains a UV-C lamp. Read the maintenance instructions before opening the appliance.
1. Do not operate UV-C lamps outside of the appliance.
2. Appliances that are obviously damaged must not be operated.
3. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C
radiation. UV-C radiation may, even in small doses, cause harm to the eyes and skin.
Page 6
Sa
f
e
t
y
Pr
e
c
a
u
t
i
o
n
s
WARNINGS FOR PRODUCT INSTALLATION
1.Installation must be performed by an authorized dealer or specialist. Defective installation can
cause water leakage, electrical shock, or fire.
2.Installation must be performed according to the installation instructions. Improper installation
can cause water leakage, electrical shock, or fire.
In North America,installation must be performed in accordance with the requirement of NEC
and CEC by authorized personnel only.)
3.Contact an authorized service technician for repair or maintenance of this unit. This appliance
shall be installed in accordance with national wiring regulations.
4.Only use the included accessories, parts, and specified parts for installation. Using non-standard
parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.
5.
6.
Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot
support the unit’s weight, or the installation is not done properly, the unit may drop and cause
serious injury and damage.
7.
8.
9.
10.
11.
Do not turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced service technicians for
disconnection and reinstallation of the unit.
How to install the appliance to its support, please read the information for details in "indoor unit
installation" and "outdoor unit installation" sections .
For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of
any combustible materials.
Do not install the unit in a location that may be exposed to combustible gas leaks. If
combustible gas accumulates around the unit, it may cause fire.
Install drainage piping according to the instructions in this manual. Improper drainage may
cause water damage to your home and property.
Note about Fluorinated Gases
1. This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the
type of gas and the amount, please refer to the relevant label on the unit itself or the
“Owner's Manual - Product Fiche ” in the packaging of the outdoor unit. (European
Union products only).
2. Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
3.Product uninstallation and recycling must be performed by a certified technician.
4. For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2
equivalent or more, but of less than 50 tonnes of CO2 equivalent, If the system has a leak-
detection system installed, it must be checked for leaks at least every 24 months.
5.
When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
4.Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol
for the conducting USER MAINTENANCE, it is recommended to disconnect the power.
5. The UV-C lamp can not be cleaned, repaired and replaced.
6. UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.
WARNING This appliance contains an UV emitter. Do not stare at the light source.
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit
may be slightly different. The actual shape shall prevail.
NOTE: Different models have different front panel and display window. Not all the indicators
describing below are available for the air conditioner you purchased. Please check the indoor display
window of the unit you purchased.
Remote Control
Remote Control
Holder (Some Units)
Louver
Front Panel
Air Filter
(pull up)
Display window
ECO intelligent eye
Display Code
Meanings
Unit Specifications and Features
Indoor unit display
Un
i
t
Sp
e
c
i
fi
c
a
t
i
o
n
s
an
d
F
e
a
t
u
r
e
s
“ ” for 3 seconds when:
• TIMER OFF is set
“
“
“
“
“ ” “ ”Displays temperature, operation feature and Error codes:
“
” when defrosting
” when Active Clean feature is turned on
” when 8°C(46°F) heating mode is turned on
” when ECO feature is activated
” when wireless control feature is activated
HumidityBoost
“ ” for 3 seconds when:
• TIMER ON is set (if the unit is OFF, remains on when TIMER ON is set )
• FRESH , UV-C lamp, SWING, TURBO , ECO, BREEZE AWAY,
ECO INTELLIGENT EYE or SILENCE feature is turned on
• FRESH , UV-C lamp, SWING, TURBO , ECO, BREEZE AWAY,
ECO INTELLIGENT EYE or SILENCE feature is turned off
“ ”
Page 7
Un
i
t
Sp
e
c
i
fi
c
a
t
i
o
n
s
an
d
F
e
a
t
u
r
e
s
Page 8
Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety
protection features may activate and cause the unit to disable.
COOL mode HEAT mode DRY mode
Room Temperature 17°C - 32°C
(62°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
-30°C - 30°C
(-22°F - 86°F)
0°C - 50°C
(32°F - 122°F)
-30°C - 50°C
(-22°F - 122°F)
To further optimize the performance of your unit, do the following:
•Keep doors and windows closed.
•Limit energy usage by using TIMER ON and TIMER OFF functions.
•Do not block air inlets or outlets.
•Regularly inspect and clean air filters.
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
Inverter Split Type
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the vertical air
flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
Un
i
t
Sp
e
c
i
fi
c
a
t
i
o
n
s
an
d
F
e
a
t
u
r
e
s
Other Features
•Auto-Restart
If the unit loses power, it will automatically
restart with the prior settings once power has
been restored.
Set temperature 1hr 1hr
Keep
running
SLEEP Operation
Saving energy during sleep
Heat mode( -1 C/2 F) per hour
for the first two hours
Cool mode(+1 C/2 F) per hour
for the first two hours
A guide on using the infrared remote is not
included in this literature package. Not all
the functions are available for the air
conditioner, please check the indoor display
and remote control of the unit you purchased.
NOTE:
For multi-split air condtioners, the following
functions are not available:
Active clean function, Silence feature, Breeze
away function, Refrigerant leakage detection
function and Eco feature.
•Anti-mildew
When turning off the unit from COOL, AUTO
(COOL), or DRY modes, the air conditioner will
continue operate at very low power to dry up
condensed water and prevent mildew growth.
•Wireless Control
Wireless control allows you to control your air
conditioner using your mobile phone and a wireless
connection.
For the USB device access, replacement,
maintenance operations must be carried out
by professional staff.
•Louver Angle Memory
When turning on your unit, the louver will
automatically resume its former angle.
•Active Clean function
-- The Active Clean Technology washes away
dust, mold, and grease that may cause odors
when it adheres to the heat exchanger by
automatically freezing and then rapidly thawing
the frost. A “pi-pi” sound will be heard.
The Active clean operation is used to produce
more condensed water to improve the cleaning
effect, and the cold air will blow out. After
cleaning, the internal wind wheel then keeps
operating with hot air to blow-dry the evaporator,
thus preventing the growth of mold and keeping
the inside clean.
-- When this function is turned on, the indoor
unit display window appears “CL ” , after 20
to 45 minutes, the unit will turn off automatically
and cancel Active Clean function.
•Breeze Away
This feature avoids direct air flow blowing on
the body and make you feel indulging in silky
coolness.
•Refrigerant Leakage Detection
The indoor unit will automatically display “EL0C” when
it detects refrigerant leakage.
•ECO Intelligent eye
The system is controlled intelligently under
Intelligent eye mode. It can detect the people’s
activities in the room. In cooling mode, when you
are away for 30 minutes, the unit will automatically
lower the frequency to save energy(for Inverter
models only). And the unit will automatically start
and resume operation if sensing human activity
again.
•Sleep Operation
The SLEEP function is used to decrease energy
use while you sleep (and don’t
need the same temperature settings to
stay comfortable). This function can only
be activated via remote control. And the Sleep
function is not available in FAN or
DRY mode.
When in COOL mode, the unit will increase the
temperature by 1°C (2°F) after 1 hour, and will
increase an additional 1°C (2°F) after another
hour.
When in HEAT mode, the unit will decrease the
temperature by 1°C (2°F) after 1 hour, and will
decrease an additional 1°C (2°F) after another
hour.
The sleep feature will stop after 8 hours and
the system will keep running with the final
temperature reached.
Page 9
Un
i
t
Sp
e
c
i
fi
c
a
t
i
o
n
s
an
d
F
e
a
t
u
r
e
s
Setting vertical angle of air flow
While the unit is on, use the SWING
button on remote control to set the direction
(vertical angle) of airflow. Please refer to the
Remote Control Manual for details.
The horizontal angle of the airflow can be set by
remote control. please refer to the Remote Control
Manual.
NOTE ON LOUVER ANGLES
When using COOL or DRY mode, do not set
louver at too vertical an angle for long periods
of time. This can cause water to condense on
the louver blade, which will drop on your floor
or furnishings.
When using COOL or HEAT mode, setting the
louver at too vertical an angle can reduce the
performance of the unit due to restricted air flow.
NOTE: According to the relative standards
requirement
please sets the vertical air flow
louver to its maximum angle under heating
capacity test
CAUTION
Do not put your fingers in or near the blower
and suction side of the unit. The high-speed
fan inside the unit may cause injury.
Fig. A
Fig. B
Setting Angle of Air Flow
Setting horizontal angle of air flow
•
To operate your unit manually:
1.Locate the MANUAL CONTROL button on
the right-hand side panel of the unit.
2.Press the MANUAL CONTROL button one
time to activate FORCED AUTO mode.
3.Press the MANUAL CONTROL button again
to activate FORCED COOLING mode.
4. Press the MANUAL CONTROL button a third
time to turn the unit off.
CAUTION
The manual button is intended for testing purposes
and emergency operation only. Please do not use this
function unless the remote control is lost and it is
absolutely necessary. To restore regular operation,
use the remote control to activate the unit. Unit must
be turned off before manual operation.
Manual Operation(without remote)
NOTE: Do not move louver by hand. This will
cause the louver to become out of sync. If this
occurs, turn off the unit and unplug it for a few
seconds, then restart the unit. This will reset the
louver.
Ran
g
e
Manual control
button
AUTO COOL
Page 10
Ca
r
e
a
n
d
Ma
i
n
t
e
n
a
n
c
e
Cleaning Your Indoor Unit
BEFORE CLEANING OR
MAINTENANCE
ALWAYS TURN OFF YOUR AIR CONDITIONER
SYSTEM AND DISCONNECT ITS POWER
SUPPLY BEFORE CLEANING OR MAINTENANCE.
CAUTION
Only use a soft, dry cloth to wipe the unit clean.
If the unit is especially dirty, you can use a cloth
soaked in warm water to wipe it clean.
•Do not use chemicals or chemically treated
cloths to clean the unit
•Do not use benzene, paint thinner,
polishing powder or other solvents to clean
the unit. They can cause the plastic surface
to crack or deform.
•Do not use water hotter than 40°C (104°F)
to clean the front panel. This can cause the
panel to deform or become discolored.
Cleaning Your Air Filter
A clogged air filter can reduce the cooling efficiency
of your unit, can also make the air flow irregular
and too much noisy, so please clean the air filter
as often as necessary. Once the abnormal noise
of air flow is heard, please clean the air filter
immediately.
1.
The air filter is on the top of the air conditioner.
2. Hold both side of the top filter in the place
marked with “PULL”, then pull it upwards.
3.If your filter has small air freshening filters,
unclip them from the larger filter. Clean these
air freshening filters with a hand-held vacuum.
4Clean the large air filter with warm, soapy
water. Be sure to use a mild detergent.
5.Rinse the filter with fresh water, then shake
off excess water.
6.Dry it in a cool, dry place, and refrain from
exposing it to direct sunlight.
7.When dry, re-clip the air freshening filter to
the larger filter, then install it back on the
indoor unit.
Hold both side of the top
filter in the place marked
with “PULL”, pull it upwards
Care and Maintenance
PULL
Remove air freshening filter from back of
larger filter(some units), clean with a hand-
held vacuum.
Page 11
Air Filter Reminders (Optional)
Air Filter Cleaning Reminder
After 240 hours of use, the display window on
the indoor unit will flash “CL.” This is a reminder
to clean your filter. After 15 seconds, the unit will
revert to its previous display.
To reset the reminder, press the LED button
on your remote control 4 times, or press the
MANUAL CONTROL button 3 times. If you don’t
reset the reminder, the “CL” indicator will flash
again when you restart the unit.
Air Filter Replacement Reminder
After 2,880 hours of use, the display window on
the indoor unit will flash “nF.” This is a reminder
to replace your filter. After 15 seconds, the unit
will revert to its previous display.
To reset the reminder, press the LED button
on your remote control 4 times, or press the
MANUAL CONTROL button 3 times. If you don’t
reset the reminder, the “nF” indicator will flash
again when you restart the unit.
Maintenance –
Long Periods of Non-Use
If you plan not to use your air conditioner for an
extended period of time, do the following:
Clean all filters Turn on FAN function until
unit dries out completely
Turn off the unit and
disconnect the power
Remove batteries
from remote control
Maintenance –
Pre-Season Inspection
After long periods of non-use, or before periods
of frequent use, do the following:
Check for damaged wires Clean all filters
Check for leaks Replace batteries
Make sure nothing is blocking all air inlets and outlets
Ca
r
e
a
n
d
Ma
i
n
t
e
n
a
n
c
e
CAUTION
•Before changing the filter or cleaning,
turn off the unit and disconnect its power
supply.
•When removing filter, do not touch metal
parts in the unit. The sharp metal edges can
cut you.
•Do not use water to clean the inside of the
indoor unit. This can destroy insulation and
cause electrical shock.
•Do not expose filter to direct sunlight when
drying. This can shrink the filter.
CAUTION
•Any maintenance and cleaning of outdoor
unit should be performed by an authorized
dealer or a licensed service provider.
•Any unit repairs should be performed
by an authorized dealer or a licensed
service provider.
Page 12
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue Possible Causes
Unit does not turn
on when pressing
ON/OFF button
The Unit has a 3-minute protection feature that prevents the unit from
overloading. The unit cannot be restarted within three minutes of being
turned off.
The unit may change its setting to prevent frost from forming on the unit.
Once the temperature increases, the unit will start operating in the
previously selected mode again.
The set temperature has been reached, at which point the unit turns off the
compressor. The unit will continue operating when the temperature
fluctuates again.
The indoor unit
emits white mist
In humid regions, a large temperature difference between the room’s air
and the conditioned air can cause white mist.
Both the indoor and
outdoor units emit
white mist
When the unit restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process.
Troubleshooting
The unit changes from
COOL/HEAT mode to
FAN mode
The indoor unit makes
noises
A rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Both the indoor unit
and outdoor unit make
noises
Low hissing sound during operation: This is normal and is caused by refrigerant
gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping or
changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
•The power cord is damaged or abnormally warm
•You smell a burning odor
•The unit emits loud or abnormal sounds
•A power fuse blows or the circuit breaker frequently trips
•Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED
SERVICE PROVIDER IMMEDIATELY!
Tr
o
u
b
l
e
s
h
o
o
t
i
n
g
Page 13
Issue Possible Causes
The outdoor unit
makes noises The unit will make different sounds based on its current operating mode.
Dust is emitted from
either the indoor or
outdoor unit
The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit during
long periods of inactivity.
The unit emits a
bad odor
The unit may absorb odors from the environment (such as furniture, cooking,
cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor
unit does not operate During operation, the fan speed is controlled to optimize product operation.
Operation is erratic,
unpredictable, or
unit is unresponsive
Interference from cell phone towers and remote boosters may cause the unit to
malfunction.
In this case, try the following:
•Disconnect the power, then reconnect.
•Press ON/OFF button on remote control to restart operation.
NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide
them with a detailed description of the unit malfunction as well as your model number.
Tr
o
u
b
l
e
s
h
o
o
t
i
n
g
Troubleshooting
When troubles occur, please check the following points before contacting a repair company.
Problem Possible Causes Solution
Poor Cooling
Performance
Temperature setting may be higher
than ambient room temperature Lower the temperature setting
The heat exchanger on the indoor
or outdoor unit is dirty
Clean the affected heat exchanger
The air filter is dirty Remove the filter and clean it according to
instructions
The air inlet or outlet of either
unit is blocked
Turn the unit off, remove the obstruction
and turn it back on
Doors and windows are open Make sure that all doors and windows are
closed while operating the unit
Excessive heat is generated
by sunlight
Close windows and curtains during periods
of high heat or bright sunshine
Too many sources of heat in the
room (people, computers,
electronics, etc.)
Reduce amount of heat sources
Low refrigerant due to leak
or long-term use
Check for leaks, re-seal if necessary and
top off refrigerant
SILENCE function is activated
(optional function)
SILENCE function can lower product
performance by reducing operating
frequency. Turn off SILENCE function.
Page 14
Tr
o
u
b
l
e
s
h
o
o
t
i
n
g
Problem Possible Causes Solution
The unit is not
working
Power failure Wait for the power to be restored
The power is turned off Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are dead Replace batteries
The Unit’s 3-minute protection
has been activated
Wait three minutes after restarting
the unit
Timer is activated Turn timer off
The unit starts and
stops frequently
There’s too much or too little
refrigerant in the system
Check for leaks and recharge the
system with refrigerant.
Incompressible gas or moisture
has entered the system.
Evacuate and recharge the system
with refrigerant
The compressor is broken Replace the compressor
The voltage is too high or
too low
Install a manostat to regulate the
voltage
Poor heating
performance
The outdoor temperature is
extremely low
Use auxiliary heating device
Cold air is entering through
doors and windows
Make sure that all doors and
windows are closed during use
Low refrigerant due to leak or
long-term use
Check for leaks, re-seal if necessary
and top off refrigerant
Indicator lamps
continue flashing The unit may stop operation or continue to run safely. If the indicator
lamps continue to flash or error codes appear, wait for about 10
minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest
customer service center.
Error code appears and
begins with the letters
as the following in the
window display of
indoor unit:
E(x), P(x), F(x)
EH(xx), EL(xx), EC(xx)
PH(xx), PL(xx), PC(xx)
•
•
•
NOTE: If your problem persists after performing the checks and diagnostics above,
turn off your unit immediately and contact an authorized service center.
Page 15
Error Codes
LED Display
EH 00
EL 01
EH 03
EH 60
EH 61
EL 0C
PC 08
EC 53
EC 52
EC 54
EC 51
EC 07
PC 00
PC 01
PC 02
PC 0L
PC 04
PC 30
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short circuit
Evaporator coil temperature sensor T2 open circuit or short circuit
Refrigerant leakage detection
Overload current protection
Outdoor ambient temperature sensor T4 open circuit or short circuit
Condenser coil temperature sensor T3 open circuit or short circuit
Compressor discharge temperature sensor TP open circuit or short circuit
Outdoor unit EEPROM parameter error
Outdoor fan speed has been out of control
IPM malfunction or IGBT over-strong current protection
Over voltage or over low voltage protection
High temperature protection of IPM module
Outdoor ambient temperature too low.
Inverter compressor drive error
Low pressure protection(Only for Multi-Zone Units)
Note:
For additional information on how to further diagnose the error codes on the unit, you can go to our website:
https://support.senville.com
Cause
Tr
o
u
b
l
e
s
h
o
o
t
i
n
g
Page 16
PC 31 High pressure protection(Only for Multi-Zone Units)
Accessories
The air conditioning system comes with the following accessories. Use all of the installation parts
and accessories to install the air conditioner. Improper installation may result in water leakage,
electrical shock and fire, or cause the equipment to fail. The items are not included
with the air conditioner must be purchased separately.
(Need to be installed on
the back of main air filter
by the authorized
technician while installing
the machine)
Remote controller
Fixing screw for
remote controller
holder
Remote controller
holder
Drain joint
Seal
Mounting plate
Manual
Ac
c
e
s
s
o
r
i
e
s
2-3
1
1
1
1
2
1
2
Battery (AAA)
Small Filter 1~2
(depending
on models)
Name of Accessories Name of AccessoriesQty (pc)Shape Qty (pc)Shape
Name Shape Quantity(PC)
Copper line set Liquid side
Gas side
Φ1/4" (6.35mm)
Φ3/8" (9.52mm)
Φ1/2" (12.7mm)
Connecting pipe assembly
The correct line set size for your unit will be included with your purchase.
Signal cable
(not included with 50 ft
line set)
1
1
Drain tube
Sealing clay
PVC tape roll
2.5"/3.5" sleeve
Edge protector for
2.5"/3.5" sleeve
1
1
2 - 4
1
1
Φ3/8" (9.52mm)
Φ5/8" (16 mm)
HumidityBoost
FRO
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
1
0
0
m
m
100 100
100
50
50 50
2
2
24
4 4
inch6
RECOMMAND
LIQUID GAS
LEVELBUBBLE
150mm
mm
inch
Page 17
In
s
t
a
l
l
a
t
i
o
n
Ov
e
r
v
i
e
w
Installation Summary - Indoor Unit
Select Installation Location Attach Mounting PlateDetermine Wall Hole Position
1 2 3
Drill Wall Hole
4
12cm
(4.75in)
2.3m (90.55in)
12cm
(4.75in)
Mount Indoor Unit
STEP 8
Wrap Piping and Cable
(not applicable for some locations in North America )
Connect Piping
Prepare Drain Hose
Connect Wiring
(not applicable for some
locations in North America )
4 5 6
7 8
9
Distance from ceiling is determinded
by the installation method.
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
1
0
0
m
m
150
100 100
100
50
50 50
2
2
2
4
4 4
6
RECOMMAND
LIQUID GAS
BUBBLE LEVEL
mm inch
mm
inch
Page 18
Un
i
t
P
a
r
t
s
NOTE: The installation must be performed in accordance with the requirement of local and
national standards. The installation may be slightly different in different areas.
Unit Parts
NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor
unit may be slightly different. The actual shape shall prevail.
Fig. 2.1
Drainage Pipe
Signal Cable
Refrigerant Piping
Remote Controller
Wall Mounting Plate
Front Panel
Louver
Air filter (pull it out)
Remote controller Holder
Electrical Panel
Power Cable to Disconnect switch
(not included)
Disconnect switch (not included)
Power cable to outdoor unit (not
included)
1
2
3
4
5
6
7
8
9
10
11
5
6
7
8 9
13
12
10
11
12
13
HumidityBoost
2
3
1
4
Page 19
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
Installation Instructions – Indoor unit
PRIOR TO INSTALLATION
Before installing the indoor unit, refer to the
label on the product box to make sure that the
model number of the indoor unit matches the
model number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must
choose an appropriate location. The following
are standards that will help you choose an
appropriate location for the unit.
Proper installation locations meet the
following standards:
Good air circulation
If the back holder is not needed to prop
up the unit:
Finishing the pipe and cable connections
before mount the indoor unit on the wall.
If the installation height is limited, 5cm from
the ceiling is allowable, but this can lower
product performance. To ensure enough
space to install and remove the top air filter,
keep at least 10cm or more from the ceiling.
The back holder is needed to prop up the
unit: If connecting pipe and cable with front
panel open, the minimum distance from
ceiling is 22cm or more, if connecting pipe
and cable without front panel(remove it) , the
minimum distance from ceiling is 11cm or
more.
Convenient drainage
Noise from the unit will not disturb other
people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the
unit
A location at least one meter from all other
electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following
locations:
Near any source of heat, steam, or
combustible gas
Near flammable items such as curtains or
clothing
Near any obstacle that might block air
circulation
Near the doorway
In a location subject to direct sunlight
NOTE ABOUT WALL HOLE:
If there is no fixed refrigerant piping:
While choosing a location, be aware that you
should leave ample room for a wall hole (see
Drill wall hole for connective piping step)
for the signal cable and refrigerant piping
that connect the indoor and outdoor units.
The default position for all piping is the right
side of the indoor unit (while facing the unit).
However, the unit can accommodate piping to
both the left and right.
Refer to the following diagram to ensure
proper distance from walls and ceiling:
NOTE:
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you
will mount the indoor unit.
Remove the screw that attaches the mounting
plate to the back of the indoor unit.
Secure the mounting plate to the wall with
screws. Make sure that mounting plate is flat
against the wall.
12cm (4.72in)
or more
2.3m (90.55in) or more
12cm (4.72in)
or more
Distance from ceiling is determinded
by the installation method.
NOTE FOR CONCRETE OR BRICK WALLS:
If the wall is made of brick, concrete, or similar
material, drill 5mm-diameter (0.2in-diameter)
holes in the wall and insert the sleeve anchors
provided. Then secure the mounting plate to
the wall by tightening the screws directly into
the clip anchors.
Screw
Indoor Unit Installation
Page 20
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
SENA/18HF/IQ
SENA/24HF/IQ
SENA/09HF/IQ
SENA/12HF/IQ
Indoor unit outline
Unit: mm(inch)Step 3: Drill wall hole for connective piping
1. Determine the location of the wall hole based
CAUTION: The Bubble level on the mounting
plate can’t be removed. If it is broken, make
sure to clean up the leaking liquid.
Vertical
direction ruler
Horizontal direction ruleron the position of the mounting plate. Refer
to Mounting Plate Dimensions.
WallIndoor Outdoor
mm
7
-
5
(0
.
2
-
0
.
2
7
5
i
n
)
Fig.3.2
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates.
For the convenience of installation, there are
bubble level, carved dimensions on the
mounting plate. Please install the plate and drill
wall hole according to the information of the
mounting plate. See the figures below.
Correct orientation of Mounting Plate
2. Using a 65mm (2.5in) or 90mm(3.54in)
(depending on models )core drill, drill a
hole in the wall. Make sure that the hole
is drilled at a slight downward angle, so
that the outdoor end of the hole is lower
than the indoor end by about 5mm to
7mm (0.2-0.275in). This will ensure proper
water drainage.
3. Place the protective wall cuff in the hole.
This protects the edges of the hole and
will help seal it when you finish the
installation process.
CAUTION
When drilling the wall hole, make sure
to avoid wires, plumbing, and other
sensitive components.
Φ
Φ
NOTE: When the gas side connective pipe is
16mm(5/8in) or more, the wall hole should
be 90mm(3.54in).
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
9
5
m
m
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
7
0
m
m
150
100 100
965(38)
795(31)
50(1.9)95(3.7)
120(4.7)
570.7(22.5)
70(2.8)
1140(44.8)
50(1.9)
pipe hole
65(2.5)
Φ
pipe hole
65(2.5)
Φ
pipe hole
65(2.5)Φ
pipe hole
65(2.5)
Φ
pipe hole
65(2.5)
50(1.9)
Φ
pipe hole
65(2.5)
490(19.3)
425(16.7)
32
2
(
1
2
.
7
)
29
5
(
1
1
.
6
)
37
0
(
1
4
.
6
)
50
(
1
.
9
)
40
(
1
.
6
)
40
(
1
.
5
)
60
(
2
.
4
)
51
(
2
.
0
)
100
50
50 50
2
2
2
4
4 4
6
RECOMMAND
LIQUID GAS
BUBBLE LEVEL
BUBBLE LEVEL
mm inch
150
100
50 2
4
6
RECOMMAND
mm inch
mm
inch
100 1005050
224 4
LIQUID GAS
mm
inch
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FR
O
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
1
0
0
m
m
150
100 100
100
50
50 50
2
2
244 4
6RECOMMAND
LIQUID GAS
BUBBLE LEVEL
mm inch
mm
inch FRO
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FRO
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
1
0
0
m
m
150
100 100
100
50
50 50
2
2
244 4
6
RECOMMAND
LIQUID GAS
BUBBLE LEVEL
mm inch
mm
inch
FRO
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
5
0
m
m
FRO
M
E
D
G
E
T
O
H
O
L
E
C
E
N
T
E
R
:
1
0
0
m
m
150
100
100
100
50
50 50
2
2
2
4
4
46RECOMMAND
LIQUID GAS
BUBBLE LEVEL
mm inch
mm
inch
BUBBLE LEVEL
150
100
50 2
4
6
RECOMMAND
mm inch
100 1005050
224 4
LIQUID GAS
mm
inch
40
(
1
.
6
)
Indoor unit outline
Indoor unit outline
Page 21
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
If refrigerant piping is already embedded in
the wall, do the following:
Step 1:Hook the indoor unit on the mounting
plate:
Step 2: Prepare refrigerant piping:
Move to left or right
30-50mm
(1.18-1.95in)
30-50mm
(1.18-1.95in)
1. Keep in mind that the hooks on the mounting plate
are smaller than the holes on the back of the unit.
If you find that you don’t have ample room to connect
embedded pipes to the indoor unit, the unit can be
adjusted left or right by about 30-50mm (1.18-1.95in),
depending on the model.
CAUTION
Be extremely careful not to dent or
damage the piping while bending them
away from the unit. Any dents in the
piping will affect the unit’s performance.
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating
sleeve attached to the back of the unit. You must
prepare the piping before passing it through the
hole in the wall. Refer to the Refrigerant Piping
Connection section of this manual for detailed
instructions on pipe flaring and flare torque
requirements, technique, etc.
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from
four different angles:
•Left-hand side
•Left rear
•Right-hand side
•
•
•
Right rear
When choose Left-hand side or Right-hand
side piping, please make sure that the pipes
come out horizontally so as not to affect the
lower panel installtion.
Refer to figures below for details.
1. Open and fix the position of the panel,
then, unscrew the screws showed in the
picture below, then hold both sides of
the lower panel in the place marked
“PULL”, pull it upwards to release the
buckles, then take the lower panel down.
Unscrew the screws
NOTE ON PIPING CONNECTING
In some locations of US, a conduit tube
must be used to connect the cable.
To ensure an enough space for the pipes
running and the machine is against the
wall after installation, It is recommended
to attach the drain hose to the right-hand
side (when you’re facing the back of the unit).
AUTO COOL
Page 22
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
Use the holder at the back
of the unit against on the
mounting plate to prop up
the unit
If there is no refrigerant piping embedded in the wall, do the following:
Step 3. Connect drain hose and refrigerant
piping (refer to Refrigerant Piping Connection
section of this manual for instructions).
Step 4. Keep pipe connection point exposed to
perform the leak test (refer to Electrical Checks
and Leak Checks section of this manual).
Step 5. After the leak test, wrap the connection
point with insulation tape.
Step 6. Remove the bracket or wedge that is
propping with insulation tape.
Step 7. Using even pressure, push down on the
bottom half of the unit. Keep pushing down
until the unit snaps onto the hooks along the
bottom of the mounting plate.
1.Based on the position of the wall hole relative
to the mounting plate, choose the side from
which the piping will exit the unit.
2. If the wall hole is behind the unit, keep the
knock-out panel in place. If the wall hole is to
the side of the indoor unit, remove the plastic
knock-out panel from that side of the unit.
(See figure below). This will create a slot through
which your piping can exit the unit. Use
needle nose pliers if the plastic panel is too
difficult to remove by hand.
3. Use scissors to cut down the length of the
insulating sleeve to reveal about 40mm (1.57in)
of the refrigerant piping. This serves two purposes:
•To facilitate the Refrigerant Piping
Connection process.
•To facilitage Gas Leak Checks and enable
you to check for dents
Knock-out Panel
(cut depending on the
actual size needed)
If need to cut the big size plastic
panel, cut as shown above.
2. Use the holder at the back of the unit to
prop up the unit, giving you enough room
to connect the refrigerant piping, signal cable,
and drain hose.
4. Use the holder at the back of the unit to
prop up the unit, giving you enough room
to connect the refrigerant piping, signal cable,
and drain hose.
5. Connect the indoor unit’s refrigerant piping
to the connective piping that will join the
indoor and outdoor units. Refer to the
Refrigerant Piping Connection section
of this manual for detailed instructions.
6. Based on the position of the wall hole
relative to the mounting plate, determine the
necessary angle of your piping.
7. Grip the refrigerant piping at the base of the bend.
8. Slowly, with even pressure, bend the piping
towards the hole. Do not dent or damage the
piping during the process.
Page 23
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
DO NOT kink the drain hose.
DO NOT create a water trap.
DO NOT put the end of drain hose in
water or a container that will collect water.
BEFORE PERFORMING ANY
ELECTRICAL WORK, READ THESE
REGULATIONS
1. All wiring must comply with local and national
electrical codes, regulations and must be
installed by a licensed electrician.
2. All electrical connections must be made according
to the Electrical Connection Diagram located on
the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
4. Power voltage should be within 90-110% of
rated voltage. Insufficient power supply can
cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, a surge
protector and main power switch should be
installed.
6. If connecting power to fixed wiring, a switch
or circuit breaker that disconnects all poles and
has a contact separation of at least 1/8in (3mm)
must be incorporated in the fixed wiring. The
qualified technician must use an approved
circuit breaker or switch.
7. Only connect the unit to an individual branch
circuit outlet. Do not connect another appliance
to that outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be firmly connected. Loose
wiring can cause the terminal to overheat,
resulting in product malfunction and possible fire.
Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts
within the unit.
If the unit has an auxiliary electric heater, it must
be installed at least 1 meter (40in) away from
any combustible materials.
To avoid getting an electric shock, never touch
the electrical components soon after the power
supply has been turned off. After turning off
the power, always wait 10 minutes or more
before you touch the electrical components.
WARNING
BEFORE PERFORMING ANY ELECTRICAL
OR WIRING WORK, TURN OFF THE
MAIN POWER TO THE SYSTEM.
10.
11.
12.
Step 5:Connect drain hose
By default, the drain hose is attached to the left-
hand side of unit (when you’re facing the back
of the unit). However, it can also be attached to
the right-hand side. To ensure proper drainage,
attach the drain hose on the same side that your
refrigerant piping exits the unit.
NOTE: In some locations of US, if the machine
has installed the conduit panel, please choose
right-hand side drainage.
Wrap the connection point firmly with Teflon
tape to ensure a good seal and to prevent leaks.
Remove the air filter and pour a small amount
of water into the drain pan to make sure that
water flows from the unit smoothly.
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose
according to the following figures.
PLUG THE UNUSED DRAIN HOLE
CORRECT
Make sure there are no kinks
or dent in drain hose to ensure
proper drainage.
NOT CORRECT
Kinks in the drain hose
will create water traps.
NOT CORRECT
Do not place the end of the
drain hose in water or in
containers that collect water.
This will prevent proper
drainage.
NOT CORRECT
Kinks in the drain hose
will create water traps.
By default, the drain hole on
the left side, when facing the
unit, is already plugged. Make
sure to always keep the unused
drain hole plugged.
Page 24
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
First remove the knok-out panel to create a
slot through whick the conduit tube can
install. Then make the cable through the
conduit tube and connect to the indoor unit.
First open the front panel, then remove
the lower panel.
Terminal
block
open the
Wire cover
Rat baffle(some units)
Knock-out
panel
Cable
clamp
NOTE: If the size of the cable is too big, remove
the middle small plastic knock-out panel to create
a slot through which the cable can exit. If you want
to remove the chassis or drain hose, please remove
the rat baffle first.
WARNING
1.Open and fix the position of the panel,
then, unscrew the screw , then hold both
sides of the lower panel in the place
marked “PULL”, pull it upwards to release
the buckles, then take the lower panel
down(please refer to Page 22-23).
2.Open the wire box cover to connect the cable.
3.Unscrew the cable clamp below the terminal
block and place it to the side.
4.Facing the back of the unit, remove the plastic
panel on the bottom left-hand side.
5. Feed the signal wire through this slot, from
the back of the unit to the front.
6. Facing the front of the unit, connect the wire
according to the indoor unit’s wiring diagram,
connect the u-lug and firmly screw each wire
to its corresponding terminal.
In North America
WARNING
BEFORE PERFORMING ANY ELECTRICAL
OR WIRING WORK, TURN OFF THE
MAIN POWER TO THE SYSTEM.
The size of the power supply cable, signal
cable, fuse, and switch needed is determined
by the maximum current of the unit. The
maximum current is indicated on the nameplate
located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse,
or switch.
Step 6: Connect signal cable
The signal cable enables communication between
the indoor and outdoor units. You can use the
cable provided with the unit as long as it
adheres with the local codes and regulations.
Cable Types
•Outdoor Power Cable: As per local
codes and regulations (not included)
•Signal Cable: SJOW
Minimum Cross-Sectional Area of
Power and Signal Cables
North America
Appliance Amps (A) AWG
15 14
20 12
30 10
40 8
55 6
CHOOSE THE RIGHT CABLE SIZE
Page 25
ALL WIRING MUST BE PERFORMED
STRICTLY IN ACCORDANCE WITH
THE WIRING DIAGRAM LOCATED
ON THE NEXT PAGE.
CAUTION
DO NOT MIX UP LIVE AND NULL WIRES
This is dangerous, and can cause the air
conditioning unit to malfunction.
7.After checking to make sure every connection
is secure, use the cable clamp to fasten the
signal cable to the unit. Screw the cable clamp
down tightly.
8. Replace the wire cover on the front of the
unit, and the plastic panel on the back.
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
NOTE ABOUT WIRING
THE WIRING CONNECTION PROCESS MAY
DIFFER SLIGHTLY BETWEEN UNITS AND
REGIONS.
Step 7: Wrappping and cables
Before passing the piping, drain hose, and the
signal cable through the wall hole, you must
bundle them together to save space, protect
them, and insulate them(This may not applicable
for some locations in US).
1.Bundle the drain hose, refrigerant pipes, and
signal cable as shown below:
DRAIN HOSE MUST BE ON BOTTOM
Make sure that the drain hose is at the bottom
of the bundle. Putting the drain hose at the
top of the bundle can cause the drain pan
to overflow, which can lead to fire or water
damage.
Indoor Unit
Signal wire Drain hose
Space behind unit
Refrigerant piping
Insulation tape
Indoor unit Outdoor unit
Red
Black
White
Green
1
L1
L2
Interconnecting
Cable
Black
Red
Green
Main Power
Cable
GND
L2
L1
2
3
1
2
3
Red
Black
White
Green
Page 26
In
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
DO NOT INTERTWINE SIGNAL CABLE WITH
OTHER WIRES
While bundling these items together, do not
intertwine or cross the signal cable with any
other wiring.
2. Using adhesive vinyl tape, attach the drain
hose to the underside of the refrigerant pipes.
3. Using insulation tape, wrap the signal wire,
refrigerant pipes, and drain hose tightly
together. Double-check that all items are
bundled.
DO NOT WRAP ENDS OF PIPING
When wrapping the bundle, keep the ends
of the piping unwrapped. You need to access
them to test for leaks at the end of the
installation process (refer to Electrical Checks
and Leak Checks section of this manual)
Step 8: Mount indoor unit
If you installed new connective piping
to the outdoor unit, do the following:
1.If you have already passed the refrigerant
piping through the hole in the wall, proceed
to Step 4.
2.Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3.Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
4.Hook the top of the indoor unit on the upper
hook of the mounting plate.
5.Check that unit is hooked firmly on mounting
by applying slight pressure to the left and
right-hand sides of the unit. The unit should
not jiggle or shift.
6.Using even pressure, push down on the
bottom half of the unit. Keep pushing down
until the unit snaps onto the hooks along the
bottom of the mounting plate.
7.Again, check that the unit is firmly mounted
by applying slight pressure to the left and the
right-hand sides of the unit.
Page 27
Ou
t
d
o
o
r
U
n
i
t
I
n
s
t
a
l
l
a
t
i
o
n
In
s
t
a
l
l
a
t
i
o
n
ev
o
b
a
)
n
i
4
2
(
m
c
0
6
60cm (
2
4
i
n
)
on rig
h
t
30cm (
1
2
i
n
)
on left
200cm
(
7
9
i
n
)
in fr
o
n
t
30cm
(
1
2
i
n
)
from
b
a
c
k
w
a
l
l
Installation Instructions – Outdoor unit
Step 1: Select installation location
Before installing the outdoor unit, you must
choose an appropriate location. The following are
standards that will help you choose an appropriate
location for the unit.
Proper installation locations meet the
following standards:
Meets all spatial requirements shown in
Installation Space Requirements above.
Good air circulation and ventilation
Firm and solid—the location can support the
unit and will not vibrate
Noise from the unit will not disturb others
Install the unit by following local codes and
regulations , there may be differ slightly
between different regions.
SPECIAL CONSIDERATIONS FOR EXTREME
WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90°
angle to the direction of the wind. If needed,
build a barrier in front of the unit to protect it
from extremely heavy winds.See Figures below.
Strong
wind
Strong wind
Strong wind
If the unit is frequently exposed to heavy
rain or snow:
Build a shelter above the unit to protect
it from the rain or snow. Be careful not to
obstruct air flow around the unit.
If the unit is frequently exposed to salty air
(seaside):
Use outdoor unit that is specially designed to
resist corrosion.
Wind Baffle
Protected from prolonged periods of direct
sunlight or rain
DO NOT install unit in the following locations:
Near an obstacle that will block air inlets
and outlets
Near a public street, crowded areas, or
where noise from the unit will disturb others
Near animals or plants that will be harmed
by hot air discharge
Near any source of combustible gas
In a location that is exposed to large
amounts of dust
In a location exposed to a excessive amounts
of salty air
Where snowfall is anticipated, raise the
unit above the base pad to prevent ice
buildup and coil damage. Mount the unit
high enough to be above the average
accumulated area snowfall. The minimum
height must be 18 inches
Outdoor Unit Installation
Page 28
Ou
t
d
o
o
r
U
n
i
t
I
n
s
t
a
l
l
a
t
i
o
n
Step 2: Install drain joint(Heat pump unit only)
Before bolting the outdoor unit in place, you must
install the drain joint at the bottom of the unit.
Note that there are two different types of drain
joints depending on the type of outdoor unit.
If the drain joint comes with a rubber seal
(see Fig. A ), do the following:
1.Fit the rubber seal on the end of the drain joint
that will connect to the outdoor unit.
2.Insert the drain joint into the hole in the base
pan of the unit.
3.Rotate the drain joint 90° until it clicks in place
facing the front of the unit.
4.Connect a drain hose extension (not included)
to the drain joint to redirect water from the
unit during heating mode.
If the drain joint doesn’t come with a rubber
seal (see Fig. B ), do the following:
1.Insert the drain joint into the hole in the base
pan of the unit. The drain joint will click in
place.
2.Connect a drain hose extension (not included)
to the drain joint to redirect water from the
unit during heating mode.
Seal
Drain joint
(A)(B)
Base pan hole of
outdoor unit
Seal
IN COLD CLIMATES
In cold climates, make sure that the drain hose
is as vertical as possible to ensure swift water
drainage. If water drains too slowly, it can
freeze in the hose and flood the unit.
The outdoor unit can be anchored to the
ground or to a wall-mounted bracket with
bolt(M10). Prepare the installation base of the
unit according to the dimensions below.
A
BD
Air inlet
Air outlet
Air inlet
W
H
Step 3: Anchor outdoor unit
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor
unit sizes and the distance between their
mounting feet. Prepare the installation base
of the unit according to the dimensions
below.
Outdoor Unit Dimensions (inch)
W x H x D
Mounting Dimensions
Distance A (inch) Distance B (inch)
31.7”x 21.8”x 12.9” (805x554x330mm)SENA/09HF/OQ
SENA/12HF/OQ
SENA/18HF/OQ
SENA/24HF/OQ
Model
number
31.7”x 21.8”x 12.9” (805x554x330mm)
20.1” (511mm)12.5” (317mm)
20.1” (511mm)12.5” (317mm)
35.0”x 26.5”x 13.5” (890x673x342mm) 26.1” (663mm)13.9” (354mm)
37.2”x 31.9”x 16.1” (946x810x410mm) 26.5” (673mm)15.9” (403mm)
Page 29
Ou
t
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
If you will install the unit on a wall-mounted
bracket , do the following:
1.Mark the position of bracket holes based on
dimensions chart.
2. Pre-drill the holes for the expansion bolts.
3. Place a washer and nut on the end of each
expansion bolt.
4. Thread expansion bolts through holes in
mounting brackets, put mounting brackets
in position, and hammer expansion bolts into
the wall.
5. Check that the mounting brackets are level.
6. Carefully lift unit and place its mounting feet
on brackets.
7. Bolt the unit firmly to the brackets.
8.If allowed, install the unit with rubber
gaskets to reduce vibrations and noise.
If you will install the unit on the ground or
on a concrete mounting platform, do the
following:
1. Mark the positions for four expansion bolts
based on dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Place a nut on the end of each expansion bolt.
4. Hammer expansion bolts into the pre-drilled
holes.
5. Remove the nuts from expansion bolts, and
place outdoor unit on bolts.
6. Put washer on each expansion bolt, then
replace the nuts.
7. Using a wrench, tighten each nut until snug.
WARNING
WHEN DRILLING INTO CONCRETE, EYE
PROTECTION IS RECOMMENDED AT ALL
TIMES.
CAUTION
Make sure that the wall is made of solid brick,
concrete, or of similarly strong material. The
wall must be able to support at least four
times the weight of the unit.
Step 4: Connect signal and power cables
The outside unit’s terminal block is protected by
an electrical wiring cover on the side of the unit.
A comprehensive wiring diagram is printed on
the inside of the wiring cover.
WARNING
BEFORE PERFORMING ANY ELECTRICAL
OR WIRING WORK, TURN OFF THE MAIN
POWER TO THE SYSTEM.
Appliance Amps (A) AWG
15 14
20 12
30 10
40 8
55 6
1.Prepare the cable for connection:
a. Using wire strippers, strip the rubber
jacket from both ends of cable to reveal
about 40mm (1.57in) of the wires inside.
b. Strip the insulation from the ends of the
wires.
c. Using a wire crimper, crimp u-lugs on the
ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you clearly
distinguish the Live (“L”) Wire from other wires.
WARNING
ALL WIRING WORK MUST BE PERFORMED
STRICTLY IN ACCORDANCE WITH THE WIRING DIAGRAM LOCATED INSIDE OF WIRE COVER OF THE OUTDOOR UNIT .
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable,
fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate
to choose the right cable, fuse, or switch.
Page 30
Ou
t
d
o
o
r
U
n
i
t
In
s
t
a
l
l
a
t
i
o
n
2. Unscrew the electrical wiring cover and remove it.
3. Unscrew the cable clamp below the terminal
block and place it to the side.
4. Connect the wire according to the wiring
diagram, and firmly screw the u-lug of each
wire to its corresponding terminal.
5. After checking to make sure every connection is
secure, loop the wires around to prevent rain
water from flowing into the terminal.
6. Using the cable clamp, fasten the cable to the
unit. Screw the cable clamp down tightly.
7. Insulate unused wires with PVC electrical tape.
Arrange them so that they do not touch any
electrical or metal parts.
8. Replace the wire cover on the side of the unit,
and screw it in place.
1. Remove the wire cover from the unit by
loosening the 3 screws.
2. Dismount caps on the conduit panel.
3. Temperarily mount the conduit tubes(not
included) on the conduit panel.
4. Properly connect both the power supply and
low voltage lines to the corresponding
terminals on the terminal block.
5. Ground the unit in accordance with local codes.
6. Be sure to size each wire allowing several inches
longer than the required length for wiring.
7. Use lock nuts to secure the conduit tubes.
In North America
Cover
Screw
G
Wire Cover
Over
1
.
5
7
i
n
.
(
4
0
m
m
)
Terminal block
Conduit panel
Connecting cable
Power supply cord
Please select the appropriate through-hole according
to the diameter of the wire.
Voltage
Minimum Circuit
Amps (MCA)
Max Overcurrent
Protection (MOP)
MainMain Power W
Size (AWG)*
208/230V - 1ph 60Hz
208/230V - 1ph 60Hz
208/230V - 1ph 60Hz
9
9
18
20
20
20
12
12
*Main power cable from electrical panel to outdoor unit
Notes:
1. Main power is supplied to outdoor unit only
2. System must be installed on a dedicated circuit
3. Follow all local building codes and NEC regulations
4. Use the above table to size your circuit breaker
12
208/230V - 1ph 60Hz 20 30 10
Three size hole: Small, Large, Medium
When the calbe is not fasten enough, use the
buckle to prop it up , so it can be clamped tightly.
Buckle
NOTE: If the cable clamp looks like the following,
please select the appropriate through-hole according to
the diameter of the wire.
SENA/09HF/OQ
SENA/12HF/OQ
SENA/18HF/OQ
SENA/24HF/OQ
Model
number
Page 31
Note on Pipe Length
Connection Instructions – Refrigerant Piping
Step 1: Cut pipes
When preparing refrigerant pipes, take extra
care to cut and flare them properly. This will
ensure efficient operation and minimize the
need for future maintenance.
1. Measure the distance between the indoor
and outdoor units.
When connecting refrigerant piping, do not let substances or gases other than the specified
refrigerant enter the unit. The presence of other gases or substances will lower the unit’s capacity,
and can cause abnormally high pressure in the refrigeration cycle. This can cause explosion and
injury.
2. Using a pipe cutter, cut the pipe a little longer
than the measured distance.
3. Make sure that the pipe is cut at a perfect 90°
angle.
Oblique Rough Warped
90°
DO NOT DEFORM PIPE
WHILE CUTTING
Be extra careful not to damage, dent, or
deform the pipe while cutting. This will
drastically reduce the heating efficiency
of the unit.
Refrigerant Piping Connection
The length of refrigerant piping will affect the performance and energy efficiency of the unit. Nominal
efficiency is tested on units with a pipe length of 16.5' (5 meters). A minimum pipe run of 10' (3 meters)
is required to minimize vibration & excessive noise. Refer to the table below for specifications on the
maximum length and drop height of piping.
Maximum Length and Drop Height of Refrigerant Piping per Unit Model
Capacity (BTU/h)Max. Length (ft)Max. Drop Height (ft)
9,000 82 (25m)33 (10m)
12,000
98 (30m)66 (20m)18,000
36,000
24,000 164 (50m)
164 (50m)82 (25m)
82 (25m)
82 (25m)33 (10m)
Re
f
r
i
g
e
r
a
n
t
p
i
p
i
n
g
Co
n
n
e
c
t
i
o
n
Page 32
6.Place flaring tool onto the form.
7.Turn the handle of the flaring tool clockwise
until the pipe is fully flared.
8.Remove the flaring tool and flare form, then
inspect the end of the pipe for cracks and
even flaring.
Step 4: Connect pipes
When connecting refrigerant pipes, be careful
not to use excessive torque or to deform the
piping in any way. You should first connect the
low-pressure pipe, then the high-pressure pipe.
MINIMUM BEND RADIUS
When bending connective refrigerant piping,
the minimum bending radius is 10cm.
4" (10cm)Radius
Instructions for Connecting Piping to
Indoor Unit
1.Align the center of the two pipes that you will
connect.
Indoor unit tubing Flare nut Pipe
Step 2: Remove burrs
Burrs can affect the air-tight seal of refrigerant
piping connection. They must be completely
removed.
1.Hold the pipe at a downward angle to prevent
burrs from falling into the pipe.
2.Using a reamer or deburring tool, remove all
burrs from the cut section of the pipe.
Pipe
Reamer
Point down
Step 3: Flare pipe ends
Proper flaring is essential to achieve an airtight
seal.
1.After removing burrs from cut pipe, seal
the ends with PVC tape to prevent foreign
materials from entering the pipe.
2.Sheath the pipe with insulating material.
3.Place flare nuts on both ends of pipe. Make
sure they are facing in the right direction,
because you can’t put them on or change
their direction after flaring.
Flare nut
Copper pipe
4.Remove PVC tape from ends of pipe when
ready to perform flaring work.
5.Clamp flare form on the end of the pipe.
The end of the pipe must extend beyond the
edge of the flare form in accordance with the
dimensions shown in the table below.
PIPING EXTENSION BEYOND FLARE FORM
Flare form
Pipe
A
Re
f
r
i
g
e
r
a
n
t
p
i
p
i
n
g
Co
n
n
e
c
t
i
o
n
Outer Diameter
of Pipe (inch)
A (inch)
Min.Max.
Ø 1/4" (Ø 6.35mm)0.0275”(0.7mm)0.05” (1.3mm)
Ø 3/8" (Ø 9.52mm)0.04” (1.0mm)0.063”(1.6mm)
Ø 1/2" ( Ø 12.7mm)0.04” (1.0mm)0.07” (1.8 mm)
Ø 5/8" ( Ø 16mm)0.078” (2.0 mm)0.086”(2.2mm)
Page 33
Re
f
r
i
g
e
r
a
n
t
p
i
p
i
n
g
Co
n
n
e
c
t
i
o
n
2.Tighten the flare nut as tightly as possible by
hand.
3.Using a spanner, grip the nut on the unit
tubing.
4.While firmly gripping the nut on the unit
tubing, use a torque wrench to tighten the
flare nut according to the torque values in the
Torque Requirements table below. Loosen
the flaring nut slightly, then tighten again.
Instructions for Connecting Piping to Outdoor Unit
USE SPANNER TO GRIP MAIN
BODY OF VALVE
Torque from tightening the flare nut can snap
off other parts of valve.
1.Unscrew the cover from the packed valve on
the side of the outdoor unit.
2.Remove protective caps from ends of valves.
3.Align flared pipe end with each valve, and
tighten the flare nut as tightly as possible by
hand.
4.Using a spanner, grip the body of the valve.
Do not grip the nut that seals the service
valve.
5.While firmly gripping the body of the valve,
use a torque wrench to tighten the flare nut
according to the correct torque values.
6.Loosen the flaring nut slightly, then tighten
again.
7.Repeat Steps 3 to 6 for the remaining pipe.
DO NOT USE EXCESSIVE TORQUE
Excessive force can break the nut or damage the refrigerant piping. You must not exceed
torque requirements shown in the table above.
Valve cover
TORQUE REQUIREMENTS
Outer Diameter of Pipe (inch) Tightening Torque (lb•ft)Add. Tightening Torque (lb•ft)
Ø 1/4" (Ø 6.35mm)13 (18N•m)15 (20N•m)
Ø 3/8" (Ø 9.52mm)24 (32N•m)29 (39N•m)
Ø 1/2" (Ø 12.7mm)36 (49N•m)43 59N•m)
Ø 5/8" (Ø 16mm)42 (57N•m)52 (71N•m)
Page 34
Ai
r
E
v
a
c
u
a
t
i
o
n
Air Evacuation
Preparations and Precautions
Air and foreign matter in the refrigerant circuit
can cause abnormal rises in pressure, which
can damage the air conditioner, reduce its
efficiency, and cause injury. Use a vacuum pump
and manifold gauge to evacuate the refrigerant
circuit, removing any non-condensable gas and
moisture from the system.
Evacuation should be performed upon initial
installation and when unit is relocated.
BEFORE PERFORMING EVACUATION
Check to make sure that both high-
pressure and low-pressure pipes between
the indoor and outdoor units are
connected properly in accordance with the
Refrigerant Piping Connection section of
this manual.
Check to make sure all wiring is connected
properly.
Evacuation Instructions
Before using the manifold gauge and vacuum
pump, read their operation manuals to familiarize
yourself with how to use them properly.
1.Connect the blue charge hose of the
manifold gauge to the service port on the
outdoor unit’s low pressure valve.
Manifold Gauge
Outdoor
Unit
Vacuum Pump
Manifold
Low
Pressure
Valve
Left
Manifold
Gauge Port
Blue Charge Hose
Yellow
Charge Hose
Middle
Manifold
Gauge Port
Larger Low
Pressure
Valve
Service
Port
1/4” to 5/16”
Adaptor for
R134A
Coolant
Smaller
High
Pressure
Valve
Manifold
High
Pressure
Valve
00-350
10
0
150
200 250
30
0
35
0
0
10
0
200
300 400
500
500
600
Fig. 6.1 Air Evacuation
4.
5.
6.Evacuation is now complete. Close the
left (blue) manifold low pressure valve and
switch off the vacuum pump.
7.Wait at least 30 minutes and then check
the left (blue) manifold gauge to verify
that ther has been no change in system
pressure. If there is a change in pressure,
refer to the Gas Leak Check section for
how to check for leaks.
Note that the service port has a
Schrader valve similar to a tire valve that
will open and close when attaching and
removing the hose.
2. Connect the yellow charge hose from t
manifold gauge to the vacuum pump.
3.Close the right (red) manifold high
pressure valve.
Open the left (blue) manifold low pressure
valve. The left gauge should read zero
pressure.
Switch on the vacuum pump and run it for
at least 15 minutes until the left gauge
move slightly counter-clockwise to show a
negative pressure of about -30 inHg.
Refrigerant Release Instructions
1.The unit comes pre-charged with
refrigerant. After checking that there has
been no change in the system pressure,
unscrew the cap on the outdoor unit's high
pressure valve (the smaller upper valve).
Fig. 6.2
Flare nut
Valve stemValve body
Cap
Page 35
Ai
r
E
v
a
c
u
a
t
i
o
n
1.Inset a hex wrench into the valve and turn it
about a 1/4 turn to release some refrigerant
into the system. Once the needle moves, close
the valve. The system is now partially
pressurized.
2.Wait for a few minutes to make sure that
there is no change in pressure. The system is
ready to be fully pressurized.
3.Unscrew the blue charge hose from the
service port quickly to minimize the release of
refrigerant throught the Schrader valve.
4.Remove the cap friom the low pressure valve
(the larger lower valve). Using the hex wrench,
open both valves until theu hit thier stops. The
system is now pressurized.
5.Screw back all three caps on all valves and
ports and tughten them by hand.
OPEN VALVE STEMS GENTLY
When opening valve stems, turn the hexagonal
wrench until it hits against the stopper. Do not
try to force the valve to open further.
Note on Adding Refrigerant (R410a)
ADDITIONAL REFRIGERANT PER PIPE LENGTH
Depending on the length of the installed piping, you may need to add additional refrigerant to
your system. The unit comes pre-charged for 25' (7.5m) of piping with R410a type refrigerant.
The additional refrigerant to be charged can be calculated using the following formula:
Connective
Pipe Length (ft)
Air Purging
Method Additional Refrigerant
< 25'Vacuum Pump None
>25'Vacuum Pump
Liquid Side: Ø 1/4" (ø 6.35mm)
(Pipe length – 25') x 0.16oz/ft
(Pipe length – 7.5m) x 15g/m
Liquid Side: Ø 3/8" (ø 9.52mm)
(Pipe length – 25') x 0.32oz/ft
(Pipe length – 7.5m) x 30g/m
CAUTION
DO NOT mix refrigerant types.
Page 36
El
e
c
t
r
i
c
a
l
a
n
d
Ga
s
L
e
a
k
C
h
e
c
k
s
Electrical Safety Checks
After installation, confirm that all electrical wiring
is installed in accordance with local and national
regulations, and according to the Installation
Manual.
BEFORE TEST RUN
Check Grounding Work
Measure grounding resistance by visual detection
and with grounding resistance tester. Grounding
resistance must be less than 0.1.
Note: This may not be required for some
locations in North America.
DURING TEST RUN
Check for Electrical Leakage
During the Test Run, use an electroprobe and
multimeter to perform a comprehensive electrical
leakage test.
If electrical leakage is detected, turn off the unit
immediately and call a licensed electrician to find
and resolve the cause of the leakage.
Note: This may not be required for some
locations in North America.
Gas Leak Checks
There are two different methods to check for gas
leaks.
Soap and Water Method
Using a soft brush, apply soapy water or liquid
detergent to all pipe connection points on the
indoor unit and outdoor unit. The presence of
bubbles indicates a leak.
Leak Detector Method
If using leak detector, refer to the device’s
operation manual for proper usage instructions.
AFTER PERFORMING GAS LEAK CHECKS
After confirming that the all pipe connection
points DO NOT leak, replace the valve cover on
the outside unit.
WARNING – RISK OF
ELECTRIC SHOCK
ALL WIRING MUST COMPLY WITH LOCAL
AND NATIONAL ELECTRICAL CODES,
AND MUST BE INSTALLED BY A LICENSED
ELECTRICIAN.
Before Test Run
Only perform test run after you have completed
the following steps:
•Electrical Safety Checks – Confirm that
the unit’s electrical system is safe and
operating properly
•Gas Leak Checks – Check all flare nut
connections and confirm that the system is
not leaking
•Confirm that gas and liquid (high and low
pressure) valves are fully open
A: Low pressure stop valve
B: High pressure stop valve
C& D: Indoor unit flare nuts
Check-point of indoor unit
Check-point of outdoor unit
A
B C
D
Electrical and Gas Leak Checks
Page 37
Te
s
t
R
u
n
Test Run Instructions
You should perform the Test Run for at least 30
minutes.
1.Connect power to the unit.
2.Press the ON/OFF button on the remote
controller to turn it on.
3.Press the MODE button to scroll through the
following functions, one at a time:
•COOL – Select lowest possible temperature
•HEAT – Select highest possible temperature
4.Let each function run for 5 minutes, and
perform the following checks:
List of Checks to Perform PASS/FAIL
No electrical leakage
Unit is properly grounded
All electrical terminals
properly covered
Indoor and outdoor units
are solidly installed
All pipe connection
points do not leak
Outdoor
(2):
Indoor
(2):
Water drains properly
from drain hose
All piping is properly
insulated
Unit performs COOL
function properly
Unit performs HEAT
function properly
Indoor unit louvers
rotate properly
Indoor unit responds to
remote controller
DOUBLE-CHECK PIPE CONNECTIONS
During operation, the pressure of the
refrigerant circuit will increase. This may
reveal leaks that were not present during your
initial leak check. Take time during the Test
Run to double-check that all refrigerant pipe
connection points do not have leaks. Refer to
Gas Leak Check section for instructions.
5.After the Test Run is successfully completed,
and you confirm that all checks points in List
of Checks to Perform have PASSED, do the
following:
a.Using remote control, return unit to
normal operating temperature.
b.Using insulation tape, wrap the indoor
refrigerant pipe connections that you
left uncovered during the indoor unit
installation process.
IF AMBIENT TEMPERATURE IS BELOW 17°C
(62°F)
You can’t use the remote controller to turn
on the COOL function when the ambient
temperature is below 16°C. In this instance,
you can use the MANUAL CONTROL button
to test the COOL function.
Test Run
1.The MANUAL CONTROL button is located
on the right-hand side panel of the unit
Press the button 2 times to select the
COOL function.
Perform Test Run as normal.
2.
3.
Manual control
button
AUTO COOL
Page 38
Pa
c
k
i
n
g
a
n
d
un
p
a
c
k
i
n
g
t
h
e
u
n
i
t
Instructions for packing and unpacking the unit:
Unpacking:
Indoor unit:
1.Cut the sealing tape on the carton with a knife, one cut on the left, one cut in the middle and one
cut on the right.
2.Use the vice to take out the sealing nails on the top of the carton.
3.Open the carton.
4.Take out the middle support plate if it is included.
5.Take out the accessory package, and take out the connecting wire if it is included.
6.Lift the machine out of the carton and lay it flat.
7.Remove the left and right package foam or the upper and lower packaging foam, untie the
packaging bag.
Outdoor Unit
1.Cut the packing belt.
2.Take the unit out of the carton.
3.Remove the foam from the unit.
4.Remove the packaging bag from the unit.
Packing:
Indoor unit:
1.Put the indoor unit into the packing bag.
2.Attach the left and right package foam or the upper and lower packaging foam to the unit.
3.Put the unit into the carton, then put accessory package in.
4.Close the carton and seal it with the tape.
5.Using the packing belt if necessary.
Outdoor unit:
1.Put the outdoor unit into the packing bag.
2.Put the bottom foam into the box.
3.Put the unit into the carton, then put the upper packaging foam on the unit.
4.Close the carton and seal it with the tape.
5.Using the packing belt if necessary.
NOTE: Please keep all packaging items if you may need in the future.
Packing and unpacking the unit
Page 39
CS014UI-EP(B)
16122000009397
20210719
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
Any updates to the manual will be uploaded to the service website:
https://support.senville.com, please check for the latest version.