Loading...
HomeMy WebLinkAbout20250402 4 Oakland Dr. Residential Generator NOD Tamie Ehinger, Chair r f CITY OF SARATOGA SPRINGS Rob DuBoff, Vice Chair DESIGN REVIEW BOARD Chris Bennett Leslie DiCarlo Jeff Gritsavage City Hall - 474 Broadway Geoff wood _ Y Y 9 �` Saratoga Springs, New York 12866 Karen Cavotta,Alternate O.RATE� Tel: 518-587-3550 x.251 7 NOTICE OF DECISION In the matter of the application #20250402 4 Oakland Drive Residential Generator 4 Oakland Drive Saratoga Springs, New York 12866 involving Architectural review of installation of a residential standby generator within the Urban Residential-1 (UR-1) District. tax parcel # 166.10-2-23, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEAR: Q Type II action—exempt from further SEAR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on May 28, 2025: Q Approve the project as submitted or shown on the attached plans Note: this approval shall expire 18 months from the issuance date unless any necessary building permit has been issued and actual work begun. Record of vote: motion to approve made by: T Ehinger, seconded by: G Wood; passed 7-0 In favor: TEhinger, CBennett, I_DiCarlo, RDuBoff, JGritsavage, KCavotta, G Wood As a result of this decision, the applicant: ✓1 may proceed with the proposed project as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department Accounts Dept. Applicant/Agent Page 1 of 1 rf ; _ r _ J i ey A Y i ? s I ,A r Y � z - _ � °'a .{ ���! �- •`'^ "��*��� 3v ."'^ +_�^- _ - A ' - 1 _y a f , l4a a rf d" -... �. si ,.^ya4,Y -1.�M i' IF ^ �.. .. 'caw �i�- '• 6. I�.. _ '"' i� >d44 ,s. Y� �3 �ly1 Yam. f T e ���_p r�`• .t e4� :� � � �� t �� r i ld � 1 k- ip4, ��:� ��'� 1. � a ��a". :�T, '� �!�' 1'.1� -r { ';+ 1, _ r , I { JJII ii xy pM l F. Ea yc 7 , � S r 1 ' I ' !� p r v' : r v s� - .. F. ""Ees .♦ c .1 a 'w r ILI CA -41 r I 1S Awl�5 LAIr.' m {ac i� a �.�e. awy, a 4 �a Fv d�8 ,A 'i�, ,/� • a d� I � _ r,�,:x��" �"r4 � .1. ,fi �w " ,ysr w'� •$ �5?a - F � �r .4 9f �+ew�' �a l�i�,r � aF��w a�R'dr'� ' i• .y3�(4�1• '�4.,y � `'i%k S•°: �1 �� `a� � �:`'� Y1/I •r�" '' G Y +a 'i r ,��,� .r rd t 1°w 1 94 a wv '�` F9 � �ys��i4�� �,r+ �a� a � +��' ri C`•t•1� �"�" �r* � _; �{ � '� - . .� F -a•.a.. �` :1 �� �'�fyµ'�.!? ter. * { � F 'k .I,' ,• .� � dby' wr. �•a�'}� t t!7�,r 'Y - . s L, w pp A�f+Y ,rye,, y } ` _ 4 �'�_.-.ram ;�,TC � - +� re•5J �.1. �.' �I y vm­ Aq S`L♦ $ �4 n�i i �4 r , 5�`�gym..` ., '«a� � .'S,« .1, y ' y � r tr _F s n. Request for extension of current approval ❑ Identify date of original DR C approval: Current expiration date: Org.App. No. ❑ Describe,.w'by ti is extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEAR Environmental Assessment Form ❑Applicants proposing the following must complete"Part I"of the SEQR Short Environmental Assessment Form(available here: http://www.dec.ny.gov/docs/perm its ei operations df/seafpartone pdo: -Construction or expansion of a multi-family residential structure(4 units +) -Construction or expansion(exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae,satellite dishes s -Demolition s: 3 Disclosure ' Does any City officer,employee or family member thereof have a financial interest(as defined by General Municipal Law Section 809)`in this application? No ffYe's It yes,a statement&s'c1osirig the name,.residence, nature, and extent of this interest must be filed with this • I /1 ?7;5 P OJ'"nl f i• , ir)I - ..�E Cor:,: " to - r'in ' 7i�, I nr, r appllC"dtlOn. C I..) /l<.;c ;us t Form t-tv2tlahle}r=C htt p,'wwvr dcc ny�o ,14jo:•,;pc rrn+ts_ _oper.:rroJn_, .,•,I`,,,r u ' -Construction or expansion of a mulo-family resid` rui�i;r•I,;:.,,I',• r•I �,;,tt; Construction or e•xp;rns}on(exccetfing 4,'0b0 sct. ft ,• r' ,:.. al of. i,!:116pal or accessory non-residential structure Certification luntc.tticSn: facility. radio antennao, .tt fi ., c,':<i,•. , /we;the:property owner(s), or purchaser(s)/lessee(s)under contract, of the land in question, hereby request an appearance before the Design Review Commission. gy-th .signature(s) attached hereto, I/we certify that the information provided within this application and accompanying docufnegtzti4rtls,:to,'the,b Pf myLowt,kr), , le0ge�itfue,and,accurate.:I/Wefurtherun{lersta►jd.th jnter>t�gr3dlt?!�taysding false;ofi mjsipadkng;jnfor ngtig ;is grounds for immediate denial of this application. Ij�ve der tiy{ thpcjze trig'fuelf?ble!s;R� �_O,pesign,Re?✓iew ornMissign and,designatgc[,O f_s {,to-e�LeF tlae pr°FeM thl; ajssgciaxec�,with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore;'I%we agree to meet'all requirements under Article VI for Historic Review or Article Vlll for Architectural e the Zoning Code' f the City of Saratoga Springs: ; - 'tr"t'=`'•. _ . , 1. v t-t Y��Src»: _ )ir.` ::;er(s i ,:�e's1 t v c;r f t 'r •�° r o he land �q esiiw1, !e:eby r"CLlet_3n ao , • ,• to p�.aranC� F(appl'ica signatur :. h 4 J > Date 2 Z'� applican itgnature) r n{,ie �. 3•k t=,:rr ll, f; i. <'Y.rti �(I':for ir no,'.-ll I... .I. IC�lpj r]li>hC�f t%t !'IlQ t?lf ii+l�J''1`r,ltlf t„ If a�phcant is t�ot,the t;�rreri t o owner q{tqi• rooerty,the cfurrent owner must also } t.V i'r :. !% C i rJe 1� to ;, rr,r, tr, ni,�f'• +i I t'`;IlSir'�r.�n ,,. I J5;•ri:�lr 1`0�•�..,• :.. ,-r., .0 t(`Y+or?-rtlC'Ic'pi °t): fir.^h.rCCt:" Pwoe Date: "t-trrt(.i•..:• _T1rrin115^ir'+n- -' ✓lI•" Owner'Signatue ;;nn�sr,r.t _ w_ ._ Da __ _------- -- - (•,9t.'.r .) }t;ai•'. Ir`J�i^ (.' "t`` r Zit. r _ GENERAC® 10/14/18 kW GUARDIAN R SERIES Residential Standby Generators Air-Cooled Gas Engine r , INCLUDES: Standby Power Rating G007171-0,G007172-0(Aluminum-Bisque)—10 kW 60 Hz • True Power'" Electrical Technology G007223-10,G007224-10,G007225-10(Aluminum-Bisque)—14 kW 60 Hz • Two-line multilingual digital LCD Evolution'" controller G007226-10,G007228-10(Aluminum-Bisque)—18 kW 60 Hz (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch V • Electronic governor 0 Standard Wi-Fig connectivity • System status&maintenance interval LED indicators • Sound attenuated enclosure GENERAC • Flexible fuel line connector • Natural gas or LP gas operation — • 5 Year limited warranty • Listed and labeled for installation as close as 18 in(457 Product shown with optional fascialdt mm)to a structure.* *Must be located away from doors, windows, and fresh ON or C �L usn/ /' "°aair intakes and in accordance with local codes. tXV � cus LISTED u Note:CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches.Units packaged with the Smart Switch are ETL or UL certified in the USA only. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This Generac's success in providing the most reliable generators possible.Generac's G- slate-of-the-art power maximizing regulation system is standard on all Generac Force engine lineup offers added peace of mind and reliability for when you need it models. It provides optimized FAST RESPONSE to changing load conditions and the most,The G-Force series engines are purpose built and designed to handle the MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the rigors of extended run times in high temperatures and extreme operating conditions. surge loads to the engine.Digital voltage regulation at±1%. O TRUE POWER"ELECTRICAL TECHNOLOGY:Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network form produce less than 5%Total Harmonic Distortion for utility quality power.This provides parts and service know-how for the entire unit, from the engine to the allows confident operation of sensitive electronic equipment and micro-chip based smallest electronic component. appliances,such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES:Long life and reliability are synonymous with ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY product line is offered with its own transfer systems and controls for total system compatibility. O MOBILE LINK®WI-FI CONNECTIVITY:FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smariphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast,friendly,and proactive service.With Mobile Link, users are taken care of before the next power outage. GENERAC ® �� PROMISE ss�..•�` Opt I GENERAL® 12 10/14/18 kW Features and Benefits -- Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasma moly rings help the engine run cooler,reducing oil consumption and resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life.Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non-emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple,low-cost installation. Evolution'"Controls • AUTO/MANUAIJOFF illuminated buttons Select the operating mode and provide easy,at-a-glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history,maintenance,and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load.Setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown.Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation,providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph(241 km/h).Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18 in(457 mm)away from a structure. GENERAC® 10/14/18 kW Features and Benefitscc Installation System • 14 in(35.6 cm)flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone,tablet,or computer at any time via the Mobile Link application of ' for complete peace of mind. • Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours. • Ability to view generator maintenance information Provides maintenance information for your specific model generator when scheduled maintenance is due. • Monthly report with previous month's activity Detailed monthly reports provide historical generator information. • Ability to view generator battery information Built in battery diagnostics displaying current state of the battery. • Weather information Provides detailed local ambient weather conditions for generator location. GENERAC® 10/14/18 kW Specifications Generator Model 10 kW 14 kW 18 kW Rated maximum continuous power capacity(LP) 10,000 Watts' 14,000 Wafts' 18,000 Watts` Rated maximum continuous power capacity(NG) 9,000 Watts' 14,000 Watts` 17,000 Watts' Rated voltage 240 Rated maximum continuous load current—240 volts(LP/NG) 41.7/37.5 58.3/58.3 75.0/70.8 Total Harmonic Distortion Less than 5% Main line circuit breaker 45 Amp 60 Amp 80 Amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight(lb/kg) 338/153 385/175 420/191 Dimensions(L x W x H)in/cm 48 x 25 x 29/121.9 x 63.5 x 73.7 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" 61 65 65 Sound output in dB(A)at 23 it(7 m)with generator in Quiet-Test'low-speed exercise mode" 57 55 55 Exercise duration 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series Number of cylinders 1 2 Displacement 460 cc 816 cc Cylinder block Aluminum w/cast iron sleeve Valve arrangement Overhead valve Lifter type Solid Hydraulic Ignition system Solid-state w/magneto Governor system Electronic Compression ratio 9.51 Starter 12 VDC Oil capacity including filter Approx.1.1 qt/1.0 L Approx.2.2 qt/2.1 L Operating rpm 3,600 Fuel consumption Natural Gas I11/hr(m'/hr) 1/2 Load 101(2.86) 195(5.52) 169(4.79) Full Load 127(3.60) 256(7.25) 247(6.99) Liquid Propane h3/hr(gal/hr)[Uhr] 1/2 Load 36(0.97)[3.661 65(1.81)[6.871 62(1.70)[6.451 Full Load 54(1.48)[5.621 112(3.07)[11.611 110(3.02)[11.44] Nate:Fuel pipe must be sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-7.0 in water column(0.87-1.74 kPa)for NG,10-12 in water column(2.49-2.99 kPa)for LP gas..FO BTU,content,multiply ft3/hr x 2,500(LP)or ft3/hr x 1,000(NG).For Megajoule_content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26 ING). Controls Two-line plain text multilingual LCO Simple user interface for ease of operation. Mode buttons:AUTO Automatic start on utility failure.Weekly,Bi-Weekly,or Monthly selectable exerciser. MANUAL Start with starter control,unit stays on.If utility fails,transfer to load takes place. OFF Stops unit.Power is removed.Control and charger still operate. Ready to RunlMaintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard(programmable by dealer only) Utility voltage loss/Return to utility adjustable(brownout setting) From 140-171 V/190-216 V Future set capable exerciser/Exercise set error warning Standard Run/Alarrn/Mainlenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on,7 sec rest(90 sec maximum duration). Starter lock-out Starter cannot re-engage until 5 sec after engine has slopped. Smart Battery Charger Standard Charger Faull/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaullAncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard Rating definitions—Optional Standby:Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046,UL2200,and DIN6271). `Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content,ambient temperature,altitude,engine power and condition,etc.Maximum power decreases approximately 3.5%for each 1,000 ft(304.8 m)above sea level and approximately 1%for each 10°F(6'C)above 60°F(16'C)."Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters. GENERAC® 10/14/18 kW Switch Options Limited Circuits Switch Features Model G007172-0 G007224-10 (10 kW) (14 kW) • 16 space,24 circuit.Breakers not included. No,of poles 2 • Electrically operated,mechanically-held contacts for fast,positive connections. Current rating(amps) 100 • Rated for all classes of load,100%equipment rated,both inductive and Voltage rating(VAC) 120/240,10 resistive. Utility voltage monitor(fixed)* • 2-pole,250 VAC contactors. -Pick-up 80% • 30 millisecond transfer time. -Dropout 65% • Dual coil design. Return to utility* Approx.15 sec • Rated for both copper and aluminum conductors. Exercises bi-weekly for 5 minutes* Standard • Main contacts are silver plated or silver alloy to resist welding and sticking. ETL or UL Listed Standard • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor Total circuits available 24 mounting flexibility. Tandem breaker capabilities 8 tandems • Multi listed for use with 1 in standard,tandem,GFCI,and AFCI breakers from Siemens,Murray,Eaton,and Square D for the most flexible and cost effective Circuit breaker protected install. Available RMS Symmetrical 10,000 Fault Current @ 250 Volts Dimensions *Function of Evolution controller Exercise can be set to weekly or monthly Height Width Depth W, Hi H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 H= N, Wire Ranges Conductor Lug I Neutral Lug Ground Lug 210-#14 1 210-#14 2/0-#14 DEPTH 1-W=-� Service Rated Smart Switch Features Model G007225-10 G007228-10 • Includes Smart A/C Management(SACM)module standard. No.of poles 2(14 kW) (18 kW) • Intelligently manages up to four air conditioner loads with no additional Current rating(amps) 200 hardware. Voltage rating(VAC) 120/240,10 • Up to eight large(240 VAC)loads can be managed with Smart Management Modules(SMMs). Utility voltage monitor(fixed)* • Electrically operated,mechanically-held contacts for fast,clean connections. -Pick-up 80% • Rated for all classes of load,100%equipment rated,both inductive and -Dropout 65% resistive. Return to utility* 15 sec • 2-pole,250 VAC contactors. Exercises bi-weekly for 5 minutes* Standard • Service equipment rated,dual coil design. ETL or UL Listed Standard • Rated for both aluminum and copper conductors. Enclosure type NEMA/UL 3R • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected 22,000 • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor Lug range 250 MCM-#6 mounting flexibility. *Function of Evolution Controller Dimensions Exercise can be set to weekly or monthly W,— 200 Amps 120/240,is Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.3 cm 67.94 76.45 26.67 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM-#4 350 MCM-#6 210-#14 GENERAC® 10/14/18 kW Available Accessories Model# Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell bat- tery for use with all air-cooled standby product(excluding PowerPact°). G007101-0 Battery Pad Warmer The pad warmer rests under the battery.Recommended for use if the temperature regularly falls below 0 IF(-18 °C).(Not necessary for use with AGM-style batteries). r G007102-0 Oil Warmer Oil warmer slips directly overthe oil filter.Recommended for use if the temperature regularly falls below 0 IF(-18°C). G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications.For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may Contact Kit not need.Not compatible with 50 amp pre-wired switches. G007027-0-Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a sleek,con- toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0-Bisque Touch-Up Paint Kit If the generator enclosure is scratched or damaged,it is important to touch up the paint to protect from future corrosion.The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator en- closure. G006482-0—10 kW Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance G007216-0—14/18 kW on a Generac automatic standby generator(oil not included). G007009-0 LTE LP Fuel Level Monitor The LTE enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank.Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power fail- ure.Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0(50 amps) Smart Management Module Smart Management Modules(SMM)are used to optimize the performance of a standby generator.It manages G007006-0(100 amps) large electrical loads upon startup and sheds them to aid in recovery when overloaded.In many cases, using SMM's can reduce the overall size and cost of the system. G007169-0(413 LTE) Mobile Link`)Cellular The Mobile Link family of Cellular Accessories allow users to monitor the status of the generator from anywhere G007170-0(Wi-Fi/Ether- Accessories in the world,using a smartphone,tablet,or PC.Easily access information such as the current operating status and net) maintenance alerts.Users can connect an account with an authorized service dealer for fast,friendly,and proac- tive service.With Mobile Link,users are taken care of before the next power outage. G007220-0-Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators.This offers a sleek,con- toured appearance,as well as offers protection from rodents and insects by covering the lifting holes located in the base.Kit contains four plugs,sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs 637.E mm 1218 mm [25.1 in] 1 48.0 In] Model UPC G007171 696471074680 G007172 696471074673 G007223 696471082548 727.2 mm (28.6 in[ G007224 696471082555 G007225 696471082562 G007226 696471082579 o u o 0 G007228 696471082586 1 it 648 mm[25.5 in] 1232 mm[48.5 inl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate.See installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. GENERAC® Generac Power Systems,Inc. • S45 W29290 HWY.59,Waukesha,WI 53189 • generac.com —•---- ©2022 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice.Part No.A0000973374 Rev.C 09/19/2022