Loading...
HomeMy WebLinkAbout20250402 4 Oakland Drive Generator Application"*HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED"* (FOR OFFICE USEI CITY OF SARATOGA SPRINGS .� �. rn DESIGN REVIEW COMMISSION CITY HALL - 474 BROADWAY •/�c�RPORATEO SARATOGA SPRINGS, NEW YORK 12866-2296 TEL: 518-587-3550 X2533 www.saratoga-spilngs.org APPLICATION FOR: ARCHITECTURAL / HISTORIC REVIEW (Application #) (Project Title) Staff Review APPLICANT(S)* OWNER(S) fffnotapplicantj ATTORNEY/AGENT Name Douglas Kwazneski Address 4 Oakland Drive Saratoga Springs, NY 12866 Phone (518)256-0115 Email dkwaznes@gmail.com Identify primary contact person: 8 Applicant B Owner ❑ Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: B Owner ❑ Lessee ❑ Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: 4 Oakland Drive, Saratoga Springs, NY Date Acquired by Owner: 06/11/24 Tax Parcel #: 166 10 2 23 (for example: 165.52-4-37) Current Zoning District: UR1- Property use: a Residential ❑ Non-residential/mixed-use Type of Review: El Architectural ❑ Historic ❑ Extension/modification (of current approval) Summary description of proposed action: Generator installation on the back of the house approximately 12.5 feet from property line of the neighbor. Has a previous application been filed with the DRC for this property? a No ❑ Yes - date(s)? - App. No.(s)? Revised 01/2021 A "complete" application consists of 1 hard copy (original) , and I electronic copy of application &ALL other materials as required below: New Construction / Additions ❑ Color photographs showing site/exterior details of existing structures and adjacent properties ❑ A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning district on 17"x11" sheet. ❑ Elevation drawings showing design of all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Floor plans for proposed structure; on sheet no larger than 2'x3'— smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts oni (Front setbacks: UR-I & INST-HTR=30'; UR-4=25'; UR-2, UR-3 & NCUD-1=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2'x3' sheet — smaller preferred if legible ❑ Product literature, specifications and samples of proposed materials and colors Signage / Awnings ❑ Color photographs showing site/exterior details of existing structures, and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I "x 17" ❑ Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location ❑ Product literature, specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties ❑ Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of "architectural/historical significance", demonstrate "good cause" why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing" structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities ❑ Color photographs showing site/existing structures, and of adjacent properties ❑ Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale ❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details ❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised O1/2021 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org. App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form ❑ Applicants proposing the following must complete "Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.nX..zovldocs/permits ei operations pdf/seafpartone.pdD: - Construction or expansion of a multi -family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? ❑ No ❑ Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Owner Signature: Date: Date: Revised 01/2021 CITY OF SARATOGA SPRINGS �A^ r DESIGN REVIEW COMMISSION r� City Hall - 474 Broadway Saratoga Springs, New York 12866 /~c�RPORATEO `9�� Tel: 518-587-3550 x2533 www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/ HISTORIC REVIEWAPPLICATION 1. ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will on/y consider properly completed applications that contain 1 original and 1 digital version of the aRplication and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit • Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure • any material change to exterior of a structure including: • demolition of a structure - addition or removal of exterior architectural features - installation, removal or material changes to exterior Within a non-residential zoning district: building elements such as roof, siding, windows, doors, • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. ■ Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note — Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. Revised 01r2021 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height — consistent with historic form and context of site and surrounding properties • Scale — relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front fagade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other fagade elements • Directional Expression — compatibility with horizontal & vertical expression of surrounding structures • Massing & Open Space — relationship of structure to open space between it and adjoining buildings • Setback — compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Building materials - Color — (in non-residential zoning districts only) 5. DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga-springs. org) for meeting dates. Applications are placed on an agenda on first -come, first -served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at http://www.sargoga-springs org/5 44/Zoning-Ordinance. Revised 01(2021 -�'"° City of Saratoga Springs =i City Hail - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 www.saratoga-springs.org Office of Planning & Economic Development Application to City Council FEE Comprehensive Plan amendment $1,800 + $300/acre Zoning Ordinance amendment $800 + $300/acre Planned Unit Development PUD amendment $800 + $300/acre Application to Zoning Board of Appeals Use Variance $1,400 + $50/app Area Variance - Residential (1 & 2 Family) $35011 st var +$50/app +$150/ea add variance Area Variance - 3+ Family and Commercial $1000/1st var + $50/app+ $200/ ea add variance Interpretations $650 + $50/app Post Work Application Fee Application Fee x 2 + $50/app Variance extensions 50% of Application fee + $50/app Residential Structures -1 or 2 Family Principal or Accessory Structure Materials Change -roof, windows, siding $75 Fagade Change-removal/additlon of windows, doors, porch $150 Addition or new construction $300 Approval Extension or Modification 50% of application fee 3 + /Multi -Family, Comm, Mixed -Use Principal or Accessory Structure Materials Change -roof, windows, siding, paint color $150 Signs, Awnings $150 Fagade Change-removal/addition of windows, doors, porch $300 Addition or new construction $650 Approval Extension or Modification 50% of application fee Application to Planning Board Special Use Permit $1200 + $50/app Temporary Use Permit $500 Special Use Permit - extension $400 Special Use Permit - modification $550 + $50/app Site Plan Review - incl. PUD: Sketch Plan $400 per sketch Site Plan Full Residential $400 + $250/unit Non-residential $800 + $150/1000 sf Administrative SPR Residential $400 Non-residential $800 Extension Residential $250 Non-residential $350 Subdivision - incl. PUD: Sketch Plan $400 per sketch Preliminary Approval Residential: 1-5 lots $700 + $50/app Residential: 6-10 lots $1100 + $50/app Residential: 11-20 lots $1450 + $50/app Residential: 21+ lots $1800 + $50/app Residential - extension $350 Final Approval Residential $1,550 + $200/lot + $50/app Non- Residential $2,400/lot + $50/app Final Approval Modification Residential $400 + $50/app Non- Residential $800 + $50/app Final Approval Extension Residential $250 Non- Residential $350 Other: Lot Line Adjustment/Subdivision Administrative Action $400 Letter of Credit - modification or extension $400 Letter of Credit - collection up to 1 % of LoC Recreation Fee $2000/lot or unit Land Disturbance $750 + $35/acre Watercourse/Wetland Permit $750 SEQRA EIS Review Draft & Final TBD w`1 11 �� E _ 1 w +r y 1 71 r.� Request for extension of current approval ❑ Identify date of original. DRC approval: Current expiration date: Org. App. No. 1 ❑ Describq w' hyafbis,extepsion is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEAR Environmental Assessment Form ❑ Applicants proposing the following must complete "Part I" of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny,izov/docs/perm its el operations df/seafpartone pd0: - Construction or expansion of a multi -family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure' Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809)'in this application? No I CTes ill" yes, a statement` disclosing the name, residence, nature, and extent of this interest must be filed with this V p�liattOn. i - + I r:c l!:), A<:sr,,, nlsrt Form Itwallable ht c ht:j, :,,,,rtivir rJcc ny�:�r�cw:.`wpc•rrtnt�_,<�_np�r..rrom_ I 'I l,hll. - Constructiz ,a or- Pxpan5l011 of a multi -family residi.�inirr st,,:ca.lr�• !q unit!, ' COnstrue-tiOn or' expaansion (excect lnr 4,DM so. ft. l!ro,,s floor areal of a i,: incipal or accessary non-residential structure Certificationtun!( ,•;ons facility. radio anre,nnar, dlsh( s /wethe:property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. Bar, th;e•signature(s) attached hereto, I/we certify that the information provided within this application and accompanying docufnegtztigrt-js; ,to, the; bes ,of my/.our*r)q Yleclge�itrue,ancl accurate...1/we further tin{ @r44-ao4.thag�IMentiRr}*,,:p ,,ofv�ding false;of; m_1sipa0kng inforrn}ti, n is grounds for immediate denial of this application. I(�ve bertstiy;` thprjze t(lg M,eMblef$�R t� ,Resign;Re?+iew QrnmissiQn and,c1esignaXftc[,0 �f-�!%toetlteFtlae psrg?ecpjfa this associaxpq,with this application for purposes of conducting any necessary site inspections relating to this application. " Furthermore; IUwe agree toImeet'all requirements under Article VII for Historic Review or Article Vlll for Architectural Rgy�ie; r Frie Zoning Code' f the City of Saratoga Springs: v t ac rc: j; • :.vr� r ! r�urciasser(:e's1',ndor cc; o of the iand +�7 tlestion, i e: eby r�G:i � 2 an pearancc ,• F(aPPI'ica signatur t, Da�e: v,•'s, a .. ?,.,,,,,. :. ,,. •`-r: , -,,n ,.,.�:. , , i _,;, Date � 2 , apRL, an tgnature) t.I: rfr .:%,l: ( 1i4 41�}b �,.—}:!GL�i,l3,, for h6r-t9W authPf-ip, 1"4)Q, tllf+iiti-'A`[ �10f L(-,V,,{�:.':J�if1 t.w,�:1 1 C,: l7i'• ,,;. �., , f\ �_�i < �l,d%xf` � e,�; Pit+ +,.�!.s If aPphcan�t tsaio #the c�irrenl_ We owner o!{ tfie.�r o,",, the current owner must also sigh , 1T),J c� 1 I ill. ,)<�„• • ti C 1 i eft .�" i� t�l:•. Zt �:fiC.1i¢�'�:� (f"trt(ac�r,'Yuji'e. �h.:/o ;,;,r„r� rr, rli,�r. ,;!i rr�l'l�;irt,�l,,.,l• � ., - WI1T S1gf;V�A'irr, t•�` ".i'. .. •.r Ili.. ��•� ('f.:, .... :lr A1--:rl. ;'°i `o Architect: Date: Date: _. r .,l �Ol{'�021.S n':,'.ci';`I ,ire r 3; •` + �Iv i��• ,r`�' ,l rf,: 10/14/18 kW INCLUDES: • True Power'" Electrical Technology • Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch • Electronic governor • Standard Wi-Fig connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled for installation as close as 18 in (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when you need it the most, The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK® WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC® GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007171-0, G007172-0 (Aluminum -Bisque) —10 kW 60 Hz G007223-10, G007224-10, G007225-10 (Aluminum- Bisque) —14 kW 60 Hz G007226-10, G007228-10 (Aluminum - Bisque) —18 kW 60 Hz GENERAC Product shown with optional fascia kit ON or C US QUIET -TEST. � cU9 LISTEDu�k �a Note: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This stale -of -the -art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. =IGENERAC ®:, @-, PROMISE..• GENERAC® 10/14/18 kW Features and Benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • EPA Certified for non -emergency applications Allows unit to be used for demand response applications. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to L I % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution'" Controls • AUTO/MANUAIIOFF illuminated buttons Select the operating mode and provide easy, at -a -glance status indication in any condition. • Two-line multilingual LCD Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to verify the cleanest power is delivered to the home. • Utility interrupt delay Prevents nuisance startups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Verifies engine is ready to assume the load. Setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown. Setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. GENERAC® 10/14/18 kW Features and Benefits Installation System • 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. • Integral sediment trap Meets IFGC and NFPA 54 installation requirements. Connectivity • Ability to view generator status Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application • Ability to view generator Exercise/Run and Total Hours • Ability to view generator maintenance information • Monthly report with previous month's activity • Ability to view generator battery information • Weather information for complete peace of mind. Review the generator's complete protection profile for exercise hours and total hours. Provides maintenance information for your specific model generator when scheduled maintenance is due. Detailed monthly reports provide historical generator information. Built in battery diagnostics displaying current state of the battery. Provides detailed local ambient weather conditions for generator location. 10/14/18 kW GENERAC® Specifications Generator Model 10 kW 14 kW 18 kW Rated maximum continuous power capacity (LP) 10,000 Watts' 14,000 Watts' 18,000 Watts` Rated maximum continuous power capacity (NG) 9,000 Watts' 14,000 Watts' 17,000 Watts' Rated voltage 240 Rated maximum continuous load current — 240 volts (LP/NG) 41.7 / 37.5 58.3 / 58.3 75.0 / 70.8 Total Harmonic Distortion Less than 5% Main line circuit breaker 45 Amp 60 Amp 80 Amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power Factor 1.0 Battery requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight (lb/kg) 338/153 385/175 420/191 Dimensions (L x W x H) in / cm 48 x 25 x 29 / 121.9 x 63.5 x 73.7 Sound output in dB(A) at 23 R (7 m) with generator operating at normal load" 61 65 65 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test' low -speed exercise mode" 57 55 55 Exercise duration 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-Force 800 Series Number of cylinders 1 2 Displacement 460 cc 816 cc Cylinder block Aluminum w/ cast iron sleeve Valve arrangement Overhead valve Litter type Solid Hydraulic Ignition system Solid-state w/ magneto Governor system Electronic Compression ratio 9.51 Starter 12 VDC Oil capacity including filter Approx.1.1 qt / 1.0 L Approx. 2.2 qt / 2.1 L Operating rpm 3,600 Fuel consumption Natural Gas IW/hr (m3/hr) 1/2 Load 101 (2.86) 195 (5.52) 169 (4.79) Full Load 127 (3.60) 256 (7.25) 247 (6.99) Liquid Propane hs/hr (gal/hr) [Uhr] 112 Load 36 (0.97) [3.66] 65 (1.81) [6.87] 62 (1.70) [6.45] Full Load 54 (1.48) [5.62] 112 (3.07) [11.611 110 (3.02) [11.44] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7.0 in water column (0.87-1.74 kPa) for NG, 10-12 in water column (2.49-2.99 kPa) for LP gas. For BTU content, multiply ft3/hr x 2,500 (LP) or ft3/hr x 1,000 (NG). For Megajou[e content, multiply_m'Lbr x 93.15 (LP) or m3/hr x 37.26 ING). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OFF Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility voltage loss/Return to utility adjustable (brownout setting) From 140-171 V/ 190-216 V Future set capable exerciser/Exercise set error warning Standard Run/AlafnVMaintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on, 7 sec rest (90 sec maximum duration). Starter lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaullAncorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard Rating definitions — Optional Standby: Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046, UL2200, and DIN6271). . Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/Megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level and approximately 1 % for each 10 °F (6 °C) above 60 °F (16 °C). **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. 10/14/18 kW Limited Circuits Switch Features • 16 space, 24 circuit. Breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1 in standard, tandem, GFCI, and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install. Dimensions Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 Wire Ranges Conductor Lug Neutral Lug Ground Lug 210-#14 210-#14 2/0-#14 Service Rated Smart Switch Features • Includes Smart A/C Management (SACM) module standard. • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight large (240 VAC) loads can be managed with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Dimensions 200 Amps 120/240, is Open Transition Service Rated Height Width Hi H2 Wi W2 Depth in 26.75 30.1 10.5 13.5 6.3 cm 67.94 76.45 26.67 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM - #4 350 MCM - #6 210 - #14 GENERAC® Switch Options Model G007172-0 G007224-10 (10 kW) (14 kW) No, of poles 2 Current rating (amps) 100 Voltage rating (VAC) 120 / 240,10 Utility voltage monitor (fixed)* -Pick-up 80% -Dropout 65% Return to utility* Approx.15 sec Exercises bi-weekly for 5 minutes* Standard ETL or UL Listed Standard Total circuits available 24 Tandem breaker capabilities 8 tandems Circuit breaker protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution controller Exercise can be set to weekly or monthly WI H2 N, DEPTH i-W2 -� Model No. of poles Current rating (amps) Voltage rating (VAC) Utility voltage monitor (fixed)* -Pick-up -Dropout Return to utility* Exercises bi-weekly for 5 minutes* G007225-10 G007228-10 (14 kW) (18 kW) 2 200 120/240,10 80% 65% 15 sec Standard ETL or UL Listed Standard Enclosure type NEMA/UL 3R Circuit breaker protected 22,000 Lug range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly GENERAC® 10/14/18 kW Available Accessories Model # Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell bat- tery for use with all air-cooled standby product (excluding PowerPact°). G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may Contact Kit not need. Not compatible with 50 amp pre -wired switches. G007027-0 - Bisque Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, con- toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator en- closure. G006482-0 —10 kW Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance G007216-0 —14 / 18 kW on a Generac automatic standby generator (oil not included). G007009-0 LTE LP Fuel Level Monitor The LTE enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power fail- ure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amps) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages G007006-0 (100 amps) large electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce the overall size and cost of the system. G007169-0 (413 LTE) Mobile Link`) Cellular The Mobile Link family of Cellular Accessories allow users to monitor the status of the generator from anywhere G007170-0 (Wi-Fi/Ether- Accessories in the world, using a smartphone, tablet, or PC. Easily access information such as the current operating status and net) maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proac- tive service. With Mobile Link, users are taken care of before the next power outage. G007220-0 - Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators. This offers a sleek, con- toured appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit contains four plugs, sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC G007171 696471074680 G007172 696471074673 G007223 696471082548 G007224 696471082555 G007225 696471082562 G007226 696471082579 G007228 696471082586 GENERAC® 125.5 in] [48.5 inl LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2022 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. A0000973374 Rev. C 09/19/2022