Loading...
HomeMy WebLinkAbout20250345 551 Lake Ave Exterior Modification- Solar Array Panels ApplicationRevised  $33/,&$7,21)25 $5&+,7(&785$/+,6725,&5(9,(: APPLICANT(S)*OWNER(S)(If not applicant) ATTORNEY/AGENT Name Address Phone / / / Email Identify primary contact person: †Applicant †Owner †Attorney/Agent * An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant’s interest in premises:†Owner †Lessee †Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Tax Parcel #: . - - (for example: 165.52 – 4 – 37 ) Current Zoning District: Property use: † Residential †Non-residential/mixed-use Type of Review: †Architectural †Historic †Extension/modification (of current approval) Summary description of proposed action: Has a previous application been filed with the DRC for this property? †No †Yes – date(s)? _____________________ -App. No.(s)? _________________ 'DWH$FTXLUHGE\2ZQHUBBBBBBBBBBBBBBBBB **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** CITY OF SARATOGA SPRINGS ''(6,*115(9,(::&200,66,21 &,7< +$// %52$':$< 6$5$72*$635,1*61(:<25. 7(/; ZZZVDUDWRJDVSULQJVRUJ [FOR OFFICE USE] _____________BB $SSOLFDWLRQ   _________BB_ 'DWH UHFHLYHG  @@@@@@@@@@@@@@@@@@@@@@@@@@ 3URMHFW7LWOH 6WDII5HYLHZBBBBBBBBBBBBBBB 630 7th Ave Troy, NY 12182 (838) 839-1500 (518) 948-5316 cbreen@plugpv.com Thomas Roohan 551 Lake Ave Saratoga Springs, NY 12866 (518) 527-9266 tom@roohanrealty.com (authorized agent/contractor) 551 Lake Ave Saratoga Springs, NY 167.-1-81 Parcel number: 411589167181 Plug PV LLC - Chelsea Breen INSTALLATION OF 21.25kW CODE COMPLIANT ROOFTOP SOLAR ARRAY 50 PANELS & MICROINVERTERS BUILT : 2021 **A “complete” application consists of  Kard copZ RULJLQDO , and 1 electronic copy of application & ALL other materials as required below: New Construction / Additions †Color photographs showing site/exterior details of existing structures and adjacent properties †$GHWDLOHGVFDOHGVLWHSODQLVHVVHQWLDOIRUDFKLHYLQJPLQLPDO]RQLQJFRPSOLDQFHGHSLFWLQJERWKFXUUHQWDQGSODQQHGVWUXFWXUHV DORQJZLWKDOOEXLOGLQJSURMHFWLRQVVXFKDVGHFNVSRUFKHVVWHSVURRIRYHUKDQJVDQGFKLPQH\V7KLVVLWHSODQPXVWVKRZDOO VHWEDFNVIURPSURSHUW\ERXQGDULHVDQGDQ\HDVHPHQWVLQDGGLWLRQWRWKHGLPHQVLRQDODQGEXONVWDQGDUGVUHOHYDQWWRWKH]RQLQJ GLVWULFWRQ[VKHHW †Elevation drawings showing design of all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible †Floor plans for proposed structure; on sheet no larger than 2’x3’ – smaller permitted if legible †Product literature, specifications and samples of proposed materials and colors Change in exterior building materials(windows, doors, roof, siding, etc.), or color (in non-residential districts only) †Color photographs showing site/exterior details of existing structures and that illustrate affected features †Elevation drawings showing all sides of existing & proposed construction – label dimensions, colors, materials, lighting (fixture & lamp type, wattage), etc. - include compass bearing & scale; no larger than 2’x3’ sheet – smaller permitted if legible †Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts only (Front setbacks: UR-1 & INST-HTR=30’; UR-4=25’; UR-2, UR-3 & NCUD-1=10’) - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3’ in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2’ diameter) For any of above: †Color photographs showing site/exterior details of existing structures, and of adjacent properties †Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2’x3’ sheet – smaller preferred if legible †Product literature, specifications and samples of proposed materials and colors Signage / Awnings †Color photographs showing site/exterior details of existing structures, and adjacent properties †Plan showing location of proposed sign/awning structure on building/premises: no larger than 11”x17” †Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware †Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location †Product literature, specifications and samples of proposed materials and colors Demolition †Color photographs showing site/exterior details of existing structures, and of adjacent properties †Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale †Written description of reasons for demolition and, in addition: †For structures of “architectural/historical significance”, demonstrate “good cause” why structure cannot be preserved †For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a “contributing” structure in a National Register district (contact City staff), provide plans for site development following demolition - include a timetable and letter of credit for project completion Telecommunication facilities †Color photographs showing site/existing structures, and of adjacent properties †Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale †Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details †Consult Article 240-12.22 of the City’s Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised 0 Revised  Request for extension of current approval †Identify date of original DRC approval: ______________Current expiration date: ________________ Org. App. No. ____________ †Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form †Applicants proposing the following must complete “Part I” of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits_ej_operations_pdf/seafpartone.pdf): - Construction or expansion of a multi-family residential structure (4 units +) - Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure - Telecommunications facility, radio antennae, satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law Section 809) in this application? †No † Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification I/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date: (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property, the current owner must also sign. Owner Signature: Date: Owner Signature: Date: 5/5/25 5/5/25 5/5/25 5/5/25 Revised  INSTRUCTIONS AARCHITECTURALL / HISTORICC REVIEWW APPLICATION 1. ELIGIBILITY:An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will RQO\ consider properly completed applications that contain  original and 1 digital version of thFBQQlication and ALL other required materials as iQGLFDWHGRQWKHDSSOLFDWLRQ +$1':5,77(11$33/,&$7,2166:,///1277%(($&&(37(' 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District x any exterior changes that require a building permit x any change in exterior building materials x a new, or change to an existing, sign or sign structure x demolition of a structure Within a non-residential zoning district: x a change in exterior building color x installation of an awning x Installation or exterior change to a structure requiring a building or demolition permit x any material change to exterior of a structure including: - addition or removal of exterior architectural features - installation, removal or material changes to exterior building elements such as roof, siding, windows, doors, porches, etc. - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. ƒWithin a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3’ in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2’ in diameter x a change in exterior building color within a non- residential zoning district x a new, or change to an existing, sign or awning x installation of telecommunications facilities Note – Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. CITYY OFF SARATOGAA SPRINGS DESIG NN REVIE WW COMMISSION City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x www.saratoga-springs.org 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: x Height – consistent with historic form and context of site and surrounding properties x Scale – relationship of structure and its architectural elements to human size, form, perception x Proportion – relationship among building elements including front façade, windows, and doors x Rhythm – pattern resulting from repeating building elements such as door/window openings, columns, arches, and other façade elements x Directional Expression – compatibility with horizontal & vertical expression of surrounding structures x Massing & Open Space – relationship of structure to open space between it and adjoining buildings x Setback – compatibility with surrounding structures x Compatibility of the following with surrounding structures/properties: -Major building elements (storefronts, doors, windows, roof) -Building materials -Color – (in non-residential zoning districts only) 5. DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of UIF GJMJOH EBUF unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6.$*(1'$'$7(: Check City’s website (www.saratoga-springs.org) for NFFUJOHEBUFT"QQMJDBUJPOTBSF QMBDFEPOBOBHFOEBPOGJSTUDPNF GJSTUTFSWFECBTJTBTEFUFSNJOFECZUIFDPNQMFUFOFTTPGUIFBQQMJDBUJPO 7. APPLICATION FEE /0/3&'6/%"#-& Make checks payable to the "Commissioner of Finance” 3&'&3505)&$633&/5'&&803,4)&&5*/$-6%&%*/5)*4%0$6.&/5 ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City’s Zoning Ordinance available in City Hall and on the City’s web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised  6 � PL UGPV (518) 948-5316 HELLO@PLUGPV.COM HTTPS://WWWPLUGPV.COM 630 7TH AVENUE, TROY, NY 12182 LETTER OF AUTHORIZATION FOR ZONING AND PERMIT APPLICATION To Whom It May Concern: I, ____________________________________________________as owner(s) of the property located at _____________________________________________________________________________________ Hereby designate PlugPV, LLC. as my contractor and registered agent for the purposes of the applying for Permits and Zoning Board representation regarding my solar installation project. Print Sign Date ________________________________ ________________________________ ________________________________ Docusign Envelope ID: DD75A64B-108E-4AAA-8C57-FF301ED0B45D 551 Lake Ave Saratoga Springs NY 12866 John Thomas Roohan 3/5/2025 John Thomas Roohan PHOTOVOLTAIC SYSTEM AERIAL VIEW APPLICABLE CODE PER LOCAL AUTHORITY HAVING JURISDICTION APPLICABLE CODES INDEX GENERAL NOTES PV1 VICINITY MAP THOMAS ROOHAN: 551 LAKE AVE, SARATOGA SPRINGS, NY 12866, USA N 43.088022, -73.71814 CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS CO V E R P A G E 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A 2017 NATIONAL ELECTRICAL CODE 2020 FIRE CODE OF NYS 2020 RESIDENTIAL CODE OF NYS 2020 BUILDING CODE OF NYS GENERAL NOTES: 1.DRAWINGS ARE DIAGRAMMATIC ONLY. THE LOCATION AND ROUTING OF RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE NOTED OR STANDARDIZED. 2.ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. 3.IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT DEVICES, OVER-CURRENT PROTECTION, GROUNDING SYSTEMS, ETC. (ALL EQUIPMENT AND MATERIALS) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 4.ALL OUTDOOR EQUIPMENT SHALL BE MIN. NEMA 3R RATED. 5.METAL CONDUIT AND ENCLOSURES SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 6.MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 6" ABOVE FLUSH VENTS. 7.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL REQUIREMENTS GIVEN BY UTILITY COMPANIES. 8.FOR ADDITIONAL EQUIPMENT SPECIFICATIONS, SEE PROVIDED CUT SHEETS. 9.ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE LOCAL AHJ. THE AHJ MAY HAVE SPECIAL LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT. THIS MAY ENCOMPASS LANGUAGE INCLUDING, BUT NOT LIMITED TO, THAT FOUND IN NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10. 10.ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. STRUCTURAL NOTES: 1.MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. 2.MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. 3.DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. ELECTRICAL NOTES: 1.ALL EQUIPMENT IS LISTED FOR USE. 2.MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. 3.ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. 4.AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. 5.ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. 6.ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED AT THAT COMPONENT. 7.ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. 8.DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM. 9.MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. 10.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. 11.FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. 12.INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. 13.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 14.THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. 15.BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. 16.ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. 17.ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. 18.DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. 19.ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS. 20.ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. PV1 PV2 PV3 PV4 PV5 - 5.1 PV6 - 6.1 COVER PAGE SITE PLAN MOUNTING PLAN MOUNTING DETAILS ELECTRICAL DIAGRAMS MARKING & LABELS *ATTACHMENTS MANUFACTURER'S SPECIFICATIONS PV7 STRUCTURAL DETAILS SYSTEM SIZE: NAMEPLATE: EQUIPMENT: PV MODULES: AC COMPONENT(S): SCOPE OF WORK: INSTALLATION OF A CODE COMPLIANT, UTILITY INTERACTIVE PHOTOVOLTAIC ELECTRIC SYSTEM. 21.25 KW DC / 14.5 KW AC MICROINVERTER:(50) ENPHASE IQ8PLUS-72-M-US MICROINVERTERS (50) JINKO SOLAR JKM425N-54HL4-B (425 W) SOLAR MODULES TYPE OF INTERCONNECTION:LINE SIDE TAP IN THE MSP (1) 100A FUSED AC DISCONNECT (1) 125A ENPHASE IQ COMBINER PANEL 5/5C 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R P R O P E R T Y L I N E 3 7 5 ' - 1 1 " 134 ' - 1 1 " 4 3 3 ' - 3 " 959 ' - 1 0 " (E) UTILITY METER (OUTSIDE GARAGE) (E)MAIN SERVICE PANEL (INSIDE GARAGE) (N) AC DISCONNECT (FUSED)(OUTSIDE GARAGE) (N) COMBINER PANEL (OUTSIDE GARAGE) LAKE AVE DRIV E W A Y P R O P E R T Y L I N E P R O P E R T Y L I N E P R O P E R T Y L I N E MP3 MP2 MP1 N CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS SI T E P L A N 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A ARRAY 1 TILT: 30° AZIMUTH: 143° ARRAY SPECIFICATIONS ARRAY 2 TILT: 30° AZIMUTH: 233° ARRAY 3 TILT: 17° AZIMUTH: 323° UTILITY METER AC DISCONNECT FUSED MAIN SERVICE PANEL 3' WIDE FIRE ACCESS PATHWAY 18'' VENTILATION SETBACK 3'x3' GROUND LADDER ACCESS POINT LEGEND COMBINER PANEL PV2 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R 49'-1" 7' - 8 " 46'-1" 8'- 2 " 42'-8" 9' - 1 0 " 45'-7" 18 ' - 4 " MP1 TILT:30° AZIMUTH: 143° MP2 TILT:30° AZIMUTH: 233° MP3 TILT:17° AZIMUTH: 323° SOLAR MODULE CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS MO U N T I N G P L A N 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A TYPE MODULE MICROINVERTER DESCRIPTION QUANTITY 42 42 1 JINKO SOLAR JKM425N-54HL4-B (425 W) SOLAR MODULES ENPHASE IQ8PLUS-72-M-US MICROINVERTER 100A FUSED AC DISCONNECTDISCONNECT 1 125A ENPHASE IQ COMBINER PANEL 5/5CCOMBINER ROOF SPECIFICATION ROOF MATERIAL ROOF CONDITION GOOD SEAM SPACING METAL @ 9" O.C. PV3 •Applicable Codes: •Ground Snow Load: •Basic Wind Speed: •Existing Roof Dead Load: •Existing Roof Live Load: ĞƐŝŐŶƌŝƚĞƌŝĂ 2020 Residential Code of NYS, ASCE 7-16 and NDS-18 50 lb/sqft 109 mph, Exposure Category B 5 lb/sqft 20.00 lb/sqft 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R “PZSE advises that best practice in snow load areas is to install staggered attachments” SOLAR MODULE METAL ROOF MINICLAMP MC K2 MINI RAIL MINIFIVEFIX STRUCTURAL ATTACHMENT DETAILS CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS ST R U C T U R A L D E T A I L S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A PV4 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A MO U N T I N G D E T A I L S PV5 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A MO U N T I N G D E T A I L S PV5.1 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R MODULES (50) JINKO SOLAR JKM425N-54HL4-B (425 W) SOLAR MODULES WATTS STC: 425W ISC: 13.58A IMP: 13.13A VOC: 38.95V VMP: 32.37V CONDUCTORS AND CONDUIT 41 2 (1) #6 THHN GND 3/4" EMT (1) #6 THHN GND 3/4"EMT 3 (3) #4 THHN 1"EMT (4) ENPHASE Q CABLES (8)#10 THHN (1) #6 THHN GND (3) #4 THHN 1"EMT (1) #6 THHN GND INVERTER(S) (50)ENPHASE IQ8PLUS-72-M-US MICROINVERTER INV OUTPUT CURRENT: 1.21 A MAX AC OUTPUT: 50X1.21 = 60.5 A INVERTER OCPD CALC :(60.5) X 1.25 = 75.625A MIN OCPD: 80A WIRE AMPACITY: 85A @75° C TERMINAL TEMPERATURE CORRECTION FACTOR: 31°-35°C = 0.96 CORRECTED WIRE AMPACITY: 81.60A OTHER EQUIPMENT (1) 100A FUSED AC DISCONNECT (1) 125A ENPHASE IQ COMBINER PANEL 5/5C G 1 STRING OF 13 MODULES WITH MICROINVERTERS 1 STRING OF 13 MODULES WITH MICROINVERTERS 1 STRING OF 12 MODULES WITH MICROINVERTERS 1 STRING OF 12 MODULES WITH MICROINVERTERS 20A/2P 20A/2P G 20A/2P 20A/2P ENVOY IQ 15A/2P 1 2 N (N) JUNCTION BOX (N) 125A ENPHASE IQ COMBINER PANEL 5/5C (OUTSIDE GARAGE) 120/240V PANEL MAIN SERVICE FUSED DISCONNECT (N) 100A AC G 3 4 (N)80A/2P (E) 400 UM NG (E)400A GEC N A (OUTSIDE GARAGE) (INSIDE GARAGE) (E) UTILITY METER (OUTSIDE GARAGE) CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS EL E C T R I C A L D I A G R A M S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A PV6 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D P ROFES S I O N A L E N GINEER P A U L K .ZAC H E R STRUCTURAL ONLY MODULES (50) JINKO SOLAR JKM425N-54HL4-B (425 W) SOLAR MODULES WATTS STC: 425W ISC: 13.58A IMP: 13.13A VOC: 38.95V VMP: 32.37V CONDUCTORS AND CONDUIT 41 2 (1) #6 THHN GND 3/4" EMT (1) #6 THHN GND 3/4"EMT 3 (3) #4 THHN 1"EMT (4) ENPHASE Q CABLES (8)#10 THHN (1) #6 THHN GND (3) #4 THHN 1"EMT (1) #6 THHN GND INVERTER(S) (50)ENPHASE IQ8PLUS-72-M-US MICROINVERTER INV OUTPUT CURRENT: 1.21 A MAX AC OUTPUT: 50X1.21 = 60.5 A INVERTER OCPD CALC :(60.5) X 1.25 = 75.625A MIN OCPD: 80A WIRE AMPACITY: 85A @75° C TERMINAL TEMPERATURE CORRECTION FACTOR: 31°-35°C = 0.96 CORRECTED WIRE AMPACITY: 81.60A OTHER EQUIPMENT (1) 100A FUSED AC DISCONNECT (1) 125A ENPHASE IQ COMBINER PANEL 5/5C G 1 STRING OF 13 MODULES WITH MICROINVERTERS 1 STRING OF 13 MODULES WITH MICROINVERTERS 1 STRING OF 12 MODULES WITH MICROINVERTERS 1 STRING OF 12 MODULES WITH MICROINVERTERS 20A/2P G ENVOY IQ 15A/2P 1 2 20A/2P 20A/2P 20A/2P N (N) JUNCTION BOX (N) 125A ENPHASE IQ COMBINER PANEL 5/5C (OUTSIDE GARAGE) G 3 4 (N)80A/2P G N UMN GEC 120/240V PANEL MAIN SERVICE FUSED DISCONNECT (N) 100A AC (E) 400 A (OUTSIDE GARAGE) (INSIDE GARAGE) (E) UTILITY METER (OUTSIDE GARAGE)(E)400 A CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS EL E C T R I C A L D I A G R A M S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A PV6.1 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFES S I O N A L E N GINEER P A U L K .ZAC H E R STRUCTURAL ONLY CO N T R A C T O R PL U G P V L L C SY S T E M DC K W : 2 1 . 2 5 AC K W : 1 4 . 5 MO D U L E S : 5 0 TH O M A S R O O H A N 5 5 1 L A K E A V E , S A R A T O G A S P R I N G S , NY 1 2 8 6 6 , U S A CO N T R A C T O R S L I C E N S E : 8 2 - 0 6 7 4 7 5 8 DATE 03/08/2025 DESIGNED BY: OZS MA R K I N G & L A B E L S 63 0 7 T H A V E , T R O Y , N Y 1 2 1 8 2 , U S A INVERTER AC DISCONNECT NEC 690.14(C)(2) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES & JUNCTION BOXES Warning: Photovoltaic Power Source NEC 690.35(F) UNGROUNDED SYSTEMS JUNCTION BOX WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NEC 705.12(D)(7) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED BREAKER. IF INSTALLED ANYWHERE ELSE ON DEADFRONT THEN A PERMANENT ARROW FROM LABEL POINTING TO PV BACKFEED BREAKER REQUIRED. MAIN SERVICE PANEL WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. WARNING NEC 705.12(D)(4)), 690.56(B) POWER IS BEING SUPPLIED TO THIS PANEL FROM THE UTILITY AND A SOLAR PV SYSTEM. NEC 690.54 RATED AC OUTPUT CURRENT: _____ A60.5 NOMINAL AC VOLTAGE: _____ V240 NEC 690.14(C)(2) PHOTOVOLTAIC AC DISCONNECT NEC 690.54 RATED AC OUTPUT CURRENT: _____ A 240 60.5 NOMINAL AC VOLTAGE: _____ V NEC 690.52 PHOTOVOLTAIC ARRAY DC DISCONNECT NOMINAL OPERATING AC VOLTAGE: 240 V NOMINAL OPERATING AC FREQUENCY: 60HZ MAX. AC POWER: 290 VA MAX AC CURRENT: 1.21 A MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT:20A NEC 690.13(4) SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION ONLY CONDUCTORS INSIDE BUILDING OR OFF THE ROOF WILL SHUT DOWN EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.56 NEC 690.31(D)(2) CONDUIT PV7 551 LAKE AVE, SARATOGA SPRINGS, NY 12866 EXP. 07/31/2027 LI C E N S E D PROFESS I O N A L E N GINEER P A U L K .ZAC H E R STRUCTURAL ONLY KEY FEATURES Superior Aesthetics Black backsheet and black frame create ideal look for residential applications. N-Type Technology N-type cells with Jinko’s in-house TOPCon technology offers better performance and improved reliability. Thick and Tough Fire Type 1 rated module engineered with a thick frame, 3.2mm front side glass, and thick backsheet for added durability. Shade Tolerant Twin array design allows continued performance even with shading by trees or debris. Protected Against All Environments Certified to withstand humidity, heat, rain, marine environments, wind, hailstorms, and packed snow. Warranty 25-year product and 30-year linear power warranty. BUILDING YOUR TRUST IN SOLAR. WWW.JINKOSOLAR.US • NYSE-listed since 2010, Bloomberg Tier 1 manufacturer • Top performance in the strictest 3rd party labs • Automated manufacturing utilizing artificial intelligence • Vertically integrated, tight controls on quality • Premium solar factories in USA, Vietnam, and Malaysia EAG LE 54HM G6 420-440 WATT • N-TYPE TOPCON Positive power tolerance of 0~+3% SOLAR PRODUCT THE MOST DEPENDABLE • ISO9001:2015 Quality Standards • ISO14001:2015 Environmental Standards • IEC61215, IEC61730 certified products • ISO45001: 2018 Occupational Health & Safety Standards • UL61730 certified products 30 N ENGINEERING DRAWINGS PACKAGING CONFIGURATION TEMPERATURE CHARACTERISTICS MAXIMUM RATINGS MECHANICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS (Two pallets = One stack) 31pcs/pallets, 62pcs/stack, 806pcs/40 HQ Container Temperature Coefficients of Pmax -0.29%/°C Temperature Coefficients of Voc -0.25%/°C Temperature Coefficients of Isc 0.045%/°C Nominal Operating Cell Temperature (NOCT)45±2°C Operating Temperature (°C)-40°C~+85°C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 25A Module Type JKM420N-54HL4-B JKM425N-54HL4-B JKM430N-54HL4-B JKM435N-54HL4-B JKM440N-54HL4-B STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax)420Wp 316Wp 425Wp 320Wp 430Wp 323Wp 435Wp 327Wp 440Wp 331Wp Maximum Power Voltage (Vmp)32.16V 29.95V 32.37V 30.19V 32.58V 30.30V 32.78V 30.50V 32.99V 30.73V Maximum Power Current (Imp)13.06A 10.55A 13.13A 10.60A 13.20A 10.66A 13.27A 10.72A 13.34A 10.77A Open-circuit Voltage (Voc)38.74V 36.80V 38.95V 37.00V 39.16V 37.20V 39.36V 37.39V 39.57V 37.59V Short-circuit Current (lsc)13.51A 10.91A 13.58A 10.96A 13.65A 11.02A 13.72A 11.08A 13.80A 11.14A Module Efficiency STC (%)21.51%21.76%22.02%22.28%22.53% ELECTRICAL PERFORMANCE & TEMPERATURE DEPENDENCE BUILDING YOUR TRUST IN SOLAR. WWW.JINKOSOLAR.US The company reserves the final right for explanation on any of the information presented hereby. JKM420-440N-54HL4-B-F1-US Voltage (V) Temperature Dependence of Isc, Voc, Pmax Current-Voltage & Power-Voltage Curves (440W) Front Cell Temperature (°C) Packaging Configuration Engineering Drawings SPECIFICATIONS Mechanical Characteristics Cell Type Curves (415W) No. of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22 kg (48.50 lbs) IP68 Rated Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5 Irradiance 800W/m2 AM=1.5NOCT: *STC: Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature() Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C ( Two pallets = One stack ) 36pcs/pallets, 72pcs/stack, 936pcs/ 40'HQ Container TUV 1×4.0mm2 (+): 400mm , (-): 200mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1722×1134×30mm (67.79×44.65×1.18 inch) 108 (6×18) N type Mono-crystalline T CONTCONCTCTSS JKM400-420N-54HL4-B-F3-EN ©2022 Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. Length: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm -40 ~+85 1000VDC (IEC) 25A 0~+3% -0.29%/ -0.25%/ 0.045%/ 45±2 kcaBed i St no r F Cu r r e n t ( A ) Voltage (V)Cell Temperature (℃) No r m a l i z e d I s c , V o c , P m a x ( % ) 14 . 0 9.0 35 33 H 17 2 2 m m ( 6 7 . 79 ") 1134mm (44.65") 86 0 m m ( 3 3 . 8 6 " ) 1086mm (42.68") 15 20 25 30 35 400 0 2 4 6 8 10 12 0 70 140 210 350 280 5 10 420 14 16 400Wp 31.28V 12.79A 37.38V 13.55A 301Wp 10.30A 28.89V 35.50V 10.94A TT CONCONCTCTSS JKM400N-54HL4-B JKM405N-54HL4-B JKM410N-54HL4-B JKM415N-54HL4-B 410Wp 31.66V 12.95A 37.77V 13.68A 308Wp 10.42A 29.59V 35.88V 11.04A 415Wp 31.85V 13.03V 37.96V 13.74A 312Wp 10.48A 29.78V 36.06V 11.09A 405Wp 31.47V 12.87A 37.58V 13.62A 305Wp 10.36A 29.08V 35.69V 11.00A -50 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax 14 0 0 m m ( 5 5 . 1 2 " ) %52 . 12%00 . 12%84 . 0220.74% STC NOCT JKM420N-54HL4-B 21.51% 420Wp 32.04V 13.11A 38.15V 13.80A 316Wp 10.54A 29.97V 36.24V 11.14A Po w e r ( W ) -25 B Packaging Configuration Engineering Drawings SPECIFICATIONS Mechanical Characteristics Cell Type Curves (415W) No. of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22 kg (48.50 lbs) IP68 Rated Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5 Irradiance 800W/m2 AM=1.5NOCT: *STC: Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature() Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C ( Two pallets = One stack ) 36pcs/pallets, 72pcs/stack, 936pcs/ 40'HQ Container TUV 1×4.0mm2 (+): 400mm , (-): 200mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1722×1134×30mm (67.79×44.65×1.18 inch) 108 (6×18) N type Mono-crystalline T CONTCONCTCTSS JKM400-420N-54HL4-B-F3-EN ©2022 Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. Length: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm -40 ~+85 1000VDC (IEC) 25A 0~+3% -0.29%/ -0.25%/ 0.045%/ 45±2 kcaBed i St no r F Cu r r e n t ( A ) Voltage (V)Cell Temperature (℃) No r m a l i z e d I s c , V o c , P m a x ( % ) 14 . 0 9.0 35 33 H 17 2 2 m m ( 6 7 . 79 ") 1134mm (44.65") 86 0 m m ( 3 3 . 8 6 " ) 1086mm (42.68") 15 20 25 30 35 400 0 2 4 6 8 10 12 0 70 140 210 350 280 5 10 420 14 16 400Wp 31.28V 12.79A 37.38V 13.55A 301Wp 10.30A 28.89V 35.50V 10.94A TT CONCONCTCTSS JKM400N-54HL4-B JKM405N-54HL4-B JKM410N-54HL4-B JKM415N-54HL4-B 410Wp 31.66V 12.95A 37.77V 13.68A 308Wp 10.42A 29.59V 35.88V 11.04A 415Wp 31.85V 13.03V 37.96V 13.74A 312Wp 10.48A 29.78V 36.06V 11.09A 405Wp 31.47V 12.87A 37.58V 13.62A 305Wp 10.36A 29.08V 35.69V 11.00A -50 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax 14 0 0 m m ( 5 5 . 1 2 " ) %52 . 12%00 . 12%84 . 02 20.74% STC NOCT JKM420N-54HL4-B 21.51% 420Wp 32.04V 13.11A 38.15V 13.80A 316Wp 10.54A 29.97V 36.24V 11.14A Po w e r ( W ) -25 B Side Back Packaging Configuration Engineering Drawings SPECIFICATIONS Mechanical Characteristics Cell Type Curves (415W) No. of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22 kg (48.50 lbs) IP68 Rated Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5 Irradiance 800W/m2 AM=1.5NOCT: *STC: Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature() Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C ( Two pallets = One stack ) 36pcs/pallets, 72pcs/stack, 936pcs/ 40'HQ Container TUV 1×4.0mm2 (+): 400mm , (-): 200mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1722×1134×30mm (67.79×44.65×1.18 inch) 108 (6×18) N type Mono-crystalline T CONTCONCTCTSS JKM400-420N-54HL4-B-F3-EN ©2022 Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. Length: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm -40 ~+85 1000VDC (IEC) 25A 0~+3% -0.29%/ -0.25%/ 0.045%/ 45±2 kcaBed i St no r F Cu r r e n t ( A ) Voltage (V)Cell Temperature (℃) No r m a l i z e d I s c , V o c , P m a x ( % ) 14 . 0 9.0 35 33 H 17 2 2 m m ( 6 7 . 79 ") 1134mm (44.65") 86 0 m m ( 3 3 . 8 6 " ) 1086mm (42.68") 15 20 25 30 35 400 0 2 4 6 8 10 12 0 70 140 210 350 280 5 10 420 14 16 400Wp 31.28V 12.79A 37.38V 13.55A 301Wp 10.30A 28.89V 35.50V 10.94A TT CONCONCTCTSS JKM400N-54HL4-B JKM405N-54HL4-B JKM410N-54HL4-B JKM415N-54HL4-B 410Wp 31.66V 12.95A 37.77V 13.68A 308Wp 10.42A 29.59V 35.88V 11.04A 415Wp 31.85V 13.03V 37.96V 13.74A 312Wp 10.48A 29.78V 36.06V 11.09A 405Wp 31.47V 12.87A 37.58V 13.62A 305Wp 10.36A 29.08V 35.69V 11.00A -50 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax 14 0 0 m m ( 5 5 . 1 2 " ) %52 . 12%00 . 12%84 . 02 20.74% STC NOCT JKM420N-54HL4-B 21.51% 420Wp 32.04V 13.11A 38.15V 13.80A 316Wp 10.54A 29.97V 36.24V 11.14A Po w e r ( W ) -25 B Length: ± 2mm Width: ± 2mm Height: ± 1mm Row Pitch: ± 2mm *STC: Irradiance 1000W/m2 NOCT: Irradiance 800W/m2 *Power measurement tolerance: ±3% Cell Temperature 25°C Ambient Temperature 20°C AM = 1.5 AM = 1.5 Wind Speed 1m/s I WARRANTY 1st year degradation not to exceed 1%, each subsequent year not to exceed 0.4%, minimum power at year 30 is 87.4% or greater. 25-year product and 30-year linear power warranty Packaging Configuration Engineering Drawings SPECIFICATIONS Mechanical Characteristics Cell Type Curves (415W) No. of cells Dimensions Weight Front Glass Frame Junction Box Output Cables 22 kg (48.50 lbs) IP68 Rated Electrical Performance & Temperature Dependence Irradiance 1000W/m2 AM=1.5 Irradiance 800W/m2 AM=1.5NOCT: *STC: Wind Speed 1m/s Module Type Maximum Power (Pmax) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Open-circuit Voltage (Voc) Short-circuit Current (Isc) Module Efficiency STC (%) Operating Temperature() Maximum system voltage Maximum series fuse rating Power tolerance Temperature coefficients of Pmax Temperature coefficients of Voc Temperature coefficients of Isc Nominal operating cell temperature (NOCT) Cell Temperature 25°C Ambient Temperature 20°C ( Two pallets = One stack ) 36pcs/pallets, 72pcs/stack, 936pcs/ 40'HQ Container TUV 1×4.0mm2 (+): 400mm , (-): 200mm or Customized Length 3.2mm,Anti-Reflection Coating, High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy 1722×1134×30mm (67.79×44.65×1.18 inch) 108 (6×18) N type Mono-crystalline T CONTCONCTCTSS JKM400-420N-54HL4-B-F3-EN ©2022 Jinko Solar Co., Ltd. All rights reserved. Specifications included in this datasheet are subject to change without notice. Length: ±2mm Width: ±2mm Height: ±1mm Row Pitch: ±2mm -40 ~+85 1000VDC (IEC) 25A 0~+3% -0.29%/ -0.25%/ 0.045%/ 45±2 kcaBed i St no r F Cu r r e n t ( A ) Voltage (V)Cell Temperature (℃) No r m a l i z e d I s c , V o c , P m a x ( % ) 14 . 0 9.0 35 33 H 17 2 2 m m ( 6 7 . 79 ") 1134mm (44.65") 86 0 m m ( 3 3 . 8 6 " ) 1086mm (42.68") 15 20 25 30 35 400 0 2 4 6 8 10 12 0 70 140 210 350 280 5 10 420 14 16 400Wp 31.28V 12.79A 37.38V 13.55A 301Wp 10.30A 28.89V 35.50V 10.94A TT CONCONCTCTSS JKM400N-54HL4-B JKM405N-54HL4-B JKM410N-54HL4-B JKM415N-54HL4-B 410Wp 31.66V 12.95A 37.77V 13.68A 308Wp 10.42A 29.59V 35.88V 11.04A 415Wp 31.85V 13.03V 37.96V 13.74A 312Wp 10.48A 29.78V 36.06V 11.09A 405Wp 31.47V 12.87A 37.58V 13.62A 305Wp 10.36A 29.08V 35.69V 11.00A -50 0 25 50 75 100 20 40 60 80 100 120 140 160 180 Isc Voc Pmax 14 0 0 m m ( 5 5 . 1 2 " ) %52 . 12%00 . 12%84 . 02 20.74% STC NOCT JKM420N-54HL4-B 21.51% 420Wp 32.04V 13.11A 38.15V 13.80A 316Wp 10.54A 29.97V 36.24V 11.14A Po w e r ( W ) -25 B I B A-A No. of Half Cells 108 (2 x 54) Dimensions 1722 × 1134 × 35mm (67.79 × 44.65 × 1.38 inch) Weight 22.0kg (48.5lbs) Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass Frame Anodized Aluminum Alloy Junction Box IP68 Rated Output Cables 12 AWG, 1400mm (55.12in) or Customized Length Connector Staubli MC4 Fire Type Type 1 Pressure Rating 5400Pa (Snow) & 2400Pa (Wind) IQ8SP-MC4-DSH-00206-3.0-EN-US-2024-02-09 IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC), which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built using advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry- leading limited warranty of up to 25 years. Connect PV modules quickly and easily to the IQ8 Series Microinverters that have integrated MC4 connectors. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-and-play connectors • Power line communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) NOTE: • IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, and so on) in the same system. • IQ Microinverters ship with default settings that meet North America’s IEEE 1547 interconnection standard requirements. Region-specific adjustments may be requested by an Authority Having Jurisdiction (AHJ) or utility representative according to the IEEE 1547 interconnection standard. An IQ Gateway is required to make these changes during installation. * Meets UL 1741 only when installed with IQ System Controller 2 or 3. ** IQ8 and IQ8+ support split-phase, 240 V installations only. DATA SHEET © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQ8SP-MC4-DSH-00206-3.0-EN-US-2024-02-09 (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC)UNITS IQ8-60-M-US IQ8PLUS-72-M-US Commonly used module pairings 1 W 235–350 235–440 Module compatibility —To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module Isc. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator. MPPT voltage range V 27–37 27–45 Operating range V 16–48 16–58 Minimum/Maximum start voltage V 22/48 22/58 Maximum input DC voltage V 50 60 Maximum continuous input DC current A 10 12 Maximum input DC short-circuit current A 25 Maximum module (Isc)A 20 Overvoltage class DC port —II DC port backfeed current mA 0 PV array configuration —Ungrounded array; no additional DC side protection required; AC side protection requires max. 20 A per branch circuit OUTPUT DATA (AC)UNITS IQ8-60-M-US IQ8PLUS-72-M-US Peak output power VA 245 300 Maximum continuous output power VA 240 290 Nominal grid voltage (L-L) V 240, split-phase (L-L), 180° Minimum and Maximum grid voltage 2 V 211-264 Maximum continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 47–68 AC short circuit fault current over three cycles Arms 2 Max units per 20 A (L-L) branch circuit 3 —16 13 Total harmonic distortion %<5 Overvoltage class AC port —III AC port backfeed current mA 30 Power factor setting —1.0 Grid-tied power factor (adjustable)—0.85 leading … 0.85 lagging Peak efficiency %97.7 CEC weighted efficiency %97 Nighttime power consumption mW 23 25 MECHANICAL DATA Ambient temperature range -40°C to 60°C (-40°F to 140°F) Relative humidity range 4% to 100% (condensing) DC connector type Stäubli MC4 Dimensions (H × W × D)212 mm (8.3”) × 175 mm (6.9”) × 30.2 mm (1.2”) Weight 1.1 kg (2.43 lbs) Cooling Natural convection–no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion-resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor © 2023 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre-wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. The IQ Combiner 5/5C, along with IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery 5P provides you with a complete grid-agnostic Enphase Energy System. 5-year limited warranty Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect (CELLMODEM-M1-06-SP-05), only with IQ Combiner 5C • Supports flexible networking: Wi-Fi, Ethernet, or cellular • Provides production metering (revenue grade) and consumption monitoring Easy to install • Mounts to one stud with centered brackets • Supports bottom, back, and side conduit entry • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV branch circuits • Bluetooth based Wi-Fi provisioning for easy Wi-Fi setup Reliable • Durable NRTL-certified NEMA type 3R enclosure • 5-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKUs • UL1741 listed X-IQ-AM1-240-5 X-IQ-AM1-240-5C IQC-5-5C-DSH-00007-2.0-EN-US-2023-09-27 IQ Battery 5P Fully integrated AC battery system. Includes six field-replaceable IQ8D-BAT Microinverters IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process IQ System Controller 3/3G Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life DATASHEET IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 (X-IQ-AM1-240-5) IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSIC12.20 ±0.5%), consumption monitoring (± 2.5%) and IQ Battery monitoring (±2.5%). Includes a silver solar shield to deflect heat IQ Combiner 5C (X-IQ-AM1-240-5C) IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ±0.5%), consumption monitoring (±2.5%) and IQ Battery monitoring (±2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)¹. Includes a silver solar shield to deflect heat WHAT’S IN THE BOX IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive, remote maintenance and management of the Enphase IQ System Busbar 125A busbar with support for 1 x IQ Gateway breaker and  4 x 20A breaker for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Prewired revenue-grade solid core CT, accurate up to 0.5% Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to 2.5% IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to 2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Enphase Mobile Connect (only with IQ Combiner 5C)4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for CTRL board ACCESSORIES AND REPLACEMENT PARTS (NOT INCLUDED, ORDER SEPARATELY) CELLMODEM-M1-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan CELLMODEM-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan Circuit breakers (off-the-shelf)Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers Supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with hold-down kit Circuit breakers (provided by Enphase)BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P- 240V-B (More details in “Accessories” section) XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for Combiner 5/5C X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B series circuit breakers (with screws) ELECTRICAL SPECIFICATIONS Rating 80 A System voltage 120/240 VAC, 60 Hz Busbar rating 125 A Fault curent rating 10 kAIC Maximum continuous current rating (input from PV/storage)64 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series distributed generation (DG) breakers only (not included) Maximum total branch circuit breaker rating (input)80 A of distributed generation/95 A with IQ Gateway breaker included IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-CLAMP)A pair of 200 A clamp-style current transformers is included with the box IQ Battery metering CT 200 A clamp-style current transformer for IQ Battery metering, included with the box ¹ A plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) IQC-5-5C-DSH-00007-2.0-EN-US-2023-09-27 k2-systems.com We support PV systems Formerly Everest Solar Systems MiniRail XPRess System TECHNICAL SHEET 1 3 Item Number Description Part Number 1 MiniRail XPRress Base 17in w/EPDM, Mill 4000667 2 MiniRL Screw w/EPDM JF3, 29g, 25mm 4000672 3 End Clamp 4000429 (mill), 4000430 (dark) 4 Mid Clamp 4000601-H (mill), 4000602-H (dark) 5 ILSCO, SGB-4, 4-14 SOL-STR OR Everest Ground Lug 4000960 4000006-H 4 5 2 5 k2-systems.com We support PV systems Formerly Everest Solar Systems MINIRAIL XPRESS MiniRail XPRess Sx 0.183 in3 (2.9988 cm3) Sy 0.176 in3 (2.8841 cm3) A (X-Section)0.507in2 (3.2709 cm2) Sectional Properties MiniRail XPRess Material 6000 Series Aluminum Ultimate Tensile Strength 37.7 ksi (260 MPa) Yield Strength 34.8 ksi (240 MPa) Weight 0.84 lbs/pc (0.378 kg/pc) Finish Mill Mechanical Properties Units: [mm] in Notes: T Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-16 T UL2703 Listed System for Fire and Bonding