20230392 78 Church 5 Story Mixed Use Development Mechanical, Lighting, Venting, Signage
Olsen Associates Architects 456 Broadway 201 April 8, 2025 Saratoga Springs New York 12866 518 583 9004 Design Review Board Fax 518 583 9122 City of Saratoga Springs 474 Broadway Saratoga Springs, NY 12866 Attention: Tamie Ehinger Re: 78 Church Street— Information regarding remainder of items requested by DRB Dear Tamie, •- Per the DRB Notice of Decision dated 02.09.2024, there were a few items needing attention for a return approval. Those items pertained to mechanical screening, lighting, signage and venting. Please see all attachments in our email pertaining to these items. The item regarding signage will be provided at a later date when finalized with the owner. For the line item pertaining to mechanical screening, we have provided a roof plan and building section showing the sightline of the roof top equipment. Please note that the heights of the heat pumps and ERV equipment will not be visible from the street level and therefore, will not require screening. The equipment is located far enough back to be hidden. We have provided elevations of the building showing the locations of the exterior lighting and reference to the product data. The fixtures are called out on the elevations as fixtures A, B and C. We also added cutsheets of the exterior light fixtures for your review. The elevations also note the exterior venting throughout. The venting includes dryer exhaust, kitchen hood exhaust, ERV and ERB intake and exhaust, and the fireplace venting. These are noted on the drawings and referenced to corresponding product data sheets. Please note that all venting will match, in color, adjacent materials in which it is located. We hope that this information is clear. We appreciate your efforts to move this process forward. If there is any additional information that the Board needs to clarify our presentation, please let us know. Sincerely, Brandi Hall Venting (D) - €RV Intake or €RB €xhauat (Typical) Light Fixture (A) - Patio Sconce (Typical) IL f�I 111� MM� F77 TITV TF t17T F77 TMHP� e e -r I l ii iii ii - li I �i IFIF11 F u: TFP� I FUl U I =- g-] 00I � I I I Limmmm m mm 00 00 00 00 Im FF 77F 0 o0 00 0 Community 78 church OO a Retail Space OO Light Fixture (5) - Entry Sconce (Typical) North Elevation April 8, 2025 1/16" = 1'-0" 78 Church St. ■ Saratoga Springs, NY ■ ■ ■ Spring City Development. ■ Olsen Associates,Architects, P.C. ■ ■ ■ Copyright©2025 Olsen Associates,Architects,P.C. Light Fixture (4) - Patio Sconce (Typical) Venting (E) - Dryer Exhaust (Typical) Venting (F) - Kitchen kood Exhaust (Typical) ® ® M o LM 0 0 0 0 e ® ® ® ❑❑ Ventin l ) V Intake or g -D ER ERB Venting (G) - Firplace Venting (Typical) ® ® ® Exhaust (Typical) ® ® UHM M ❑❑ ® ® o ■ 0 Light Fixture (G) - Overhead Light at Garage Door (Typical) East Elevation April 8, 2025 1/16" = 1'-0" 78 Church St. ■ Saratoga Springs, NY ■ ■ ■ Spring City Development. ■ Olsen Associates,Architects, P.C. ■ ■ ■ Copyright©2025 Olsen Associates,Architects,P.C. Description: A modern medium outdoor LED sconce with an architectural-inspired open linear frame and clear glass diffuser. Finished in Black. Specifications: •Clear glass Diffuser •A modern outdoor LED sconce. •LED source provides energy efficient source with low maintenance and cost savings benefits •Features an architectural-inspired open linear frame and clear glass diffuser •Finished in Black •624 lumens 66 lumens/watt per module (source) •3000K color temperature, 90+ CRI. •Meets California Title 24 - JA8 - 2016. •Dimmable to 10% brightness (See Dimming Notes) •Back plate covers a standard 4” recessed outlet box: 4.75 in W., 1 in ht., 4.75 in depth •Mounting strap for outlet box included •6 in of wire supplied Performance: Number of Modules 1 Input Power 9 W Input Voltage 120 V Input Frequency 60 Hz Lumens/LPW (Source) 624/66 (LM-82) Lumens/LPW (Delivered) 309/32.9 (LM-79) CCT 3000 K CRI 90+ Life (hours) 60000 (L70/TM-21) EMI/RFI Meets FCC Title 47, Part 15 Class B Max. Operating Temp 30º C Warranty 5-year Limited Warranty Labels cCSAus Wet Location Listed ENERGY STAR® qualified Meets California Title 24 JA8-2016 Dimensions: Width: 5-1/8 in Height: 20 in Depth: 5-3/4 in H/CTR: 2-1/4 in Clear glass Diffuser Width: 3-1/8 in Height: 16-5/16 in P560056-031-30 Z-1030 LED Wall Mounted • Wet Location Listed Project: Fixture Type: Location: Contact: A - Patio Sconce (Level 5) P560056-031-30 Dimming Notes: P560056-031-30 is designed to be compatible with many Triac/Forward Phase ELV/Reverse Phase controls. The following is a partial list of known compatible dimmer controls. Dimming Controls: Lutron_Diva DVELV-300P Lutron_Nova T NTELV-300 Lutron_Caseta Lutron_Ariadni AY-600P Leviton_Illumatech IPI06-1LZ Leviton_SureSlide 6672 Lutron_Ariadni AYCL-153P Lutron_Skylark Contour CTCL-153P Lutron_Diva DVCL-153P Lutron_Toggler TGCL-153P Lutron_Maestro MACL-153M Lutron_Ariadni AYLV-600P Lutron_Nova T NTLV-600 Lutron_Maestro MAELV-600 Lutron_spacer/system SPSELV-600 Leviton_Renoir II AWRMG-EAW Lutron_Nova N-600 Dimming capabilities will vary depending on the dimmer control, load, and circuit installation. Always refer to dimmer manufacturer instructions or a controls specialist for specific requirements. Dimmer control brand names where identified above are trade names or registered trademarks of each respective company. Z-1030 LED Wall Mounted • Wet Location Listed 280003 LAMONT TWO LIGHT OUTDOOR WALL MOUNT Timeless Lighting For Any Space Millennium Lighting 105 Declaration Drive McDonough, GA 30253 www.millenniumlighting.com FINISH TBK - Textured Black DIMENSIONS Width 8˝ Height 28.5˝ Depth 9.4˝ Backplate Width 8˝ Backplate Height 15.7˝ Backplate Depth 0.8˝ Weight 13.2 lbs MATERIAL Steel GLASS Glass Clear LAMPING # Bulbs 3-Candle Bullb Base Candelabra (E12) Watts per Bulb 60W Voltage 120V Total Wattage 180W Bulbs Included No CERTIFICATION ETL Listed Wet Location ITEM NUMBER SKU’s 280003 TBK 280003 TBK B-Entry Sconce (Level 1) SLIM Need help? Tech help line: (888) 722-1000 Email: sales@rablighting.com Website: www.rablighting.com Copyright © 2024 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 1 of 3 Color: Bronze Weight: 2.9 lbs Project:Type: Prepared By:Date: Driver Info Type Constant 120V 0.26A/0.20A/0.13A 208V 0.13A/0.10A/0.07A 240V 0.17A/0.09A/0.06A 277V 0.11A/0.08A/0.06A Input Watts 15.2-30.5W LED Info Watts 26/18/12W Color Temp 3000K/4000K/5000K Color Accuracy 82-85 CRI L70 Lifespan 100,000 Hours Lumens 2,175-4,389 lm Efficacy 135.1-150.6 lm/W Technical Specifications Field Adjustability Field Adjustable: Field Adjustable Light Output: 26W/18W/12W (factory default 26W) Color temperature selectable 3000K, 4000K and 5000K (factory default 4000K) Performance Lifespan: 100,000-Hour LED lifespan based on IES LM-80 results and TM-21 calculations Wattage Equivalency: 26W: Replaces up to 175W Metal Halide (MH) or 150W High Pressure Sodium (HPS) 18W: Replaces up to 125W Metal Halide (MH) or 100W High Pressure Sodium (HPS) 12W: Replaces up to 100W Metal Halide (MH) or 70W High Pressure Sodium (HPS) LED Characteristics LEDs: Long-life, high-efficiency, surface-mount LEDs Electrical Driver: Constant Current, Class 2, 120-277V, 50/60 Hz 26W: 120V: 0.26A, 208V: 0.13A, 240V: 0.12A, 277V: 0.11A 18W: 120V: 0.20A, 208V: 0.10A, 240V: 0.09A, 277V: 0.08A 12W: 120V: 0.13A, 208V: 0.07A, 240V: 0.06A, 277V: 0.06A Dimming Driver: Driver includes dimming control wiring for 0-10V dimming systems. Requires separate 0-10V DC dimming circuit. Dims down to 10%. THD: 26W: 3.4% at 120V, 4.68% at 277V 18W: 2.95% at 120V, 5.3% at 277V 12W: 3% at 120V, 8.42% at 277V Power Factor: 26W: 99.8% at 120V, 96.5% at 277V 18W: 99.7% at 120V, 94.6% at 277V 12W: 99.4% at 120V, 89.6% at 277V Photocell: 120-277V selectable photocell that can be turned on and off. Surge Protection: 4kV Construction Cold Weather Starting: The minimum starting temperature is -40°C (-40°F) Maximum Ambient Temperature: Suitable for use in up to 40°C (104°F) Housing: Aluminum Lens: Acrylonitrile styrene acrylate (ASA) /Acrylonitrile butadiene styrene (ABS) Reflector: Mirror finish on polycarbonate Mounting: Heavy-duty mounting bracket with spring-hinged housing and "kick stand" allow for easy installations. Conduit entries on back and both sides. Finish: Formulated for high durability and long-lasting color Green Technology: Mercury and UV free. RoHS-compliant components. C-Overhead Garage Light Fixture SLIM Need help? Tech help line: (888) 722-1000 Email: sales@rablighting.com Website: www.rablighting.com Copyright © 2024 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 2 of 3 Technical Specifications (continued) Compliance IESNA LM-79 & LM-80 Testing: RAB LED luminaires and LED components have been tested by an independent laboratory in accordance with IESNA LM-79 and LM-80. ADA Compliant: Meets ADA Requirements for wall-mounted luminaires. IP Rating: Ingress protection rating of IP65 for dust and water Trade Agreements Act Compliant: This product is a product of Cambodia and a "designated country" end product that complies with the Trade Agreements Act DLC Listed: This product is listed by Design Lights Consortium (DLC) as an ultra-efficient premium product that qualifies for the highest tier of rebates from DLC Member Utilities. Designed to meet DLC 5.1 requirements. DLC Product Code: S-IHR6QX Other Note: All values are typical (tolerance +/- 10%) Warranty: RAB warrants that our LED products will be free from defects in materials and workmanship for a period of ten (10) years from the date of delivery to the end user, including coverage of light output, color stability, driver performance and fixture finish. RAB's warranty is subject to all terms and conditions found at rablighting.com/warranty. Buy American Act Compliance: RAB values USA manufacturing! Upon request, RAB may be able to manufacture this product to be compliant with the Buy American Act (BAA). Please contact customer service to request a quote for the product to be made BAA compliant. SLIM Need help? Tech help line: (888) 722-1000 Email: sales@rablighting.com Website: www.rablighting.com Copyright © 2024 RAB Lighting All Rights Reserved Note: Specifications are subject to change at any time without notice Page 3 of 3 Dimensions Features 100,000-hour LED Life 0-10V dimming, standard Selectable on/off photocell 10-Year, No-Compromise Warranty Ordering Matrix Family Wattage Color Temp Finish Voltage/Driver SLIM Blank = 26/18/12W Blank = 3000/4000/5000K Adjustable Blank = Bronze W = White BR = Brass Blank = 120-277V, 0-10V Dimming Venting (F) - Kitchen Hood Exhaust Venting (E) - Dryer Exhaust � �-� MECHANICAL SERVICES INC. LICENSED & FULLY INSURED YOUR NEArlN6 &COOL/NO !i:PEC:l/ll.l�S: .P>;f; I � 24- HR. DEPE:NOABLI.:.: .:S.E:iR'U'..it'IC:'«;:'" EQUIPMENT SUBMITTAL: PROJECT 78 Church Street Condo's Saratoga Springs, NY 12866 Bonacio Construction CON STRACTOR 18 Division St. Saratoga Springs, NY 12866 HVAC CONTRACTOR ALBANY MECHANICAL SERVIC ES INC. 15 Albany Ave. Green Island, NY 12183 SUBMITTED Thomas Bethon Date: 11/1/24 BY EQUIPMENT: EXTERIOR EXHAUST VENTS 1.ERV INTAKE LOUVERS 2.ERB EXHAUST LOUVERS Venting (D) - ERV Intake / ERB Exhaust MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE COSMO36-IFT-B Actual Framing Actual Framing Actual Framing Actual Framing 32-1/4" x 15-1/4" [819 x 387]41" [1041] 42" [1067] 30-3/4" [781] 42"* [1067] 33-11/16" [856] 32-3/4" [832] 17-3/4" [451] 17-3/4” [451] 16-3/4"[425] 32-3/8" [822] 2-3/16"[56] 6"[152] 17-1/4" [438] 25-7/8" [657] 43-1/2"[1105] 7-3/4"[197] 41"[1041] 36"[914] 32-1/4" [819] 15-1/4" [387] 33-11 /16"[856] 3-1/2"[89] 7"[178] 46-1/2" [1181] 9-13/16"[249] 17-3/4"[451] 1/2" [13] 30-3/4"[781] GAS LINE ACCESS ELECTRICAL ACCESS 6-5/8"[168] HEAT MANAGEMENT SYSTEMS ACCESS 10-3/8"[264] 7-1/2"[191]TOP VIEW LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW 16-3/4"[425] 32-3/8" [822] 2-3/16"[56] 6"[152] 17-1/4"[438] 25-7/8" [657] 43-1/2"[1105] 7-3/4" [197] 41"[1041] 36"[914] 32-1/4" [819] 15-1/4" [387] 33-11 /16"[856] 3-1/2"[89] 7"[178] 46-1/2" [1181] 9-13/16"[249]17-3/4"[451]1/2" [13]30-3/4"[781] GAS LINE ACCESS ELECTRICAL ACCESS 6-5/8"[168] HEAT MANAGEMENTSYSTEMS ACCESS 10-3/8"[264] 7-1/2"[191] 16-3/4"[425] 32-3/8" [822] 2-3/16"[56] 6"[152] 17-1/4"[438] 25-7/8" [657] 43-1/2"[1105] 7-3/4"[197] 41"[1041] 36"[914] 32-1/4" [819] 15-1/4" [387] 33-11 /16"[856] 3-1/2"[89] 7"[178] 46-1/2" [1181] 9-13/16"[249]17-3/4"[451]1/2" [13]30-3/4"[781] GAS LINE ACCESS ELECTRICAL ACCESS 6-5/8"[168] HEAT MANAGEMENTSYSTEMS ACCESS 10-3/8"[264] 7-1/2"[191] 33-3/16" 14-1/8" 38-1/8" 6-7/8" 9-13/16" 19-7/8"26-7/8" (843) (359) (968) (175) (249) (505)(683) 33-1/4" 14-7/8" 39-3/16" 6-5/16"9-5/16" 20-3/4" 27-1/16" (845) (377) (995) (160)(237) (527)(688) CLEAN FACE TRIM MARTINI FRONT 16-3/4"[425] 32-3/8" [822] 2-3/16"[56] 6"[152] 17-1/4" [438] 25-7/8" [657] 43-1/2"[1105] 7-3/4"[197] 41"[1041] 36"[914] 32-1/4" [819] 15-1/4" [387] 33-11 /16"[856] 3-1/2"[89] 7"[178] 46-1/2" [1181] 9-13/16"[249] 17-3/4"[451] 1/2" [13] 30-3/4"[781] GAS LINE ACCESS ELECTRICAL ACCESS 6-5/8"[168] HEAT MANAGEMENTSYSTEMS ACCESS 10-3/8"[264] 7-1/2"[191] Specifications COSMO36-IFT-B Please consult the manufacturer’s installation manual for all details and requirements before making a final design layout decision. COSMO 36 Direct Vent Gas Fireplace Venting (F) Fireplace Venting APPLIANCE LOCATION WALL PENETRATION MANTEL LEG/WALL PROJECTIONS (acceptable on both sides of appliance) 47-1/2" [1207]TOP VENT ONE 900 ELBOW SEE INSTALL MANUAL FOR ALCOVE INSTALLATION TOP VENT ONE 90° ELBOW 18" [457 mm] required when Passive Heat Side Discharge Kit is installed. 1/2 IN. 47-1/2" [1207] 42" [1067] 66" [1676] 15-3/4" [400] 17-1/4" [438] Refer to Section 10.C for mantel and wall projection information in installation manual. Consider the mantel or cabinet system to be installed and comply with the necessary requirements for elevated hearth. Refer to instructions included with cabinet system. 47-1/2" 46-1/2" [1207] [1181] 10"10" DO NOT PACK WITH INSULATION OR OTHER MATERIAL • 8/17 DRAFT COPY 8-5/8" 32-3/4" 17-3/4" 42" [219] [832] [451] [1067] NOTE: Header MUST be installed on end as shown in the diagram. HEADER: Two 2 X 4s or Two 2 X 6s installed on end MINIMUM FRAMING DIMENSIONS WALL 3' MAX. 6" MIN. APPLIANCE OPENING WALLUNLIMITED 7" MIN. APPLIANCE OPENING Shows center of vent framing hole for top or rear venting. The center of the hole is 1" (25mm) above the center of the horizontal vent pipe. AREA TO COMBUSTIBLES CLEARANCE TO CEILING 31" [787] NON-COMBUSTIBLE FLOOR 0" [0] COMBUSTIBLE FLOORING 0" [0] BEHIND APPLIANCE 1/2" [13] SIDES OF APPLIANCE 1/2" [13] FRONT OF APPLIANCE 36" [914] 31" 0" 0" 1/2" 1/2" 36" [787] [13] [13] [914] MEASURE FROM TOP OF APPLIANCE OPENING TO CEILING MINIMUM FIREPLACE CLEARANCES / CLEARANCES TO COMBUSTIBLES Combustible Mantels 9 11 13 14 TO CEILING 6 9 12 3 6 8 10 11 TO CEILING 6 9 12 3 Combustible Mantels - Passive Heat Kit Installed Non-combustible Mantels 12" MAX. 1/2" THICK WALL SHEATHING 14" MIN. BOTTOM OF MANTEL TO TOP OF APPLIANCE OPENING NON-COMBUSTIBLE MANTEL 6" MAX. MANTEL PROJECTIONS (or other materials above appliance) NON-COMBUSTIBLE MANTEL PROJECTIONS (or other materials above appliance) COSMO36-IFT-BSpecifications Additional information can be found online at www.heatnglo.com Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury. Lakeville, MN Web: heatnglo.com 952-985-6000 PRODUCT LISTING CODES US ANSI Z21.88-2017 CAN CSA 2.33-2017 UL307B HNG/COSMO36-IFT-B_0220 DI R E C T V E N T G A S F I R E P L A C E CO S M O Available IntelliFire® app and voice control COSMO Clean lines and elegant ambiance never go out of style. Make the look your own with three sizes and several front and interior finishing options. Choose from traditional or driftwood logs. Set the mood with LED accent lighting and a long ribbon of flame. Operate your fireplace from an intuitive and safe control. Add heat management and direct the heat where you want it. Place your TV above with the optional Passive Heat kit. COSMO 36 using Passive Heat kit, shown with clean face trim in graphite, fade-resistant black glass reflective panels, river rocks and LED accent lights COSMO CRYSTAL GLASS BLACK GLASS BEADS WHITE GLASS BEADSAMBER GLASSBLACK GLASS BLUE GLASS RIVER ROCK INTERIOR OPTIONS FADE-RESISTANT REFLECTIVE BLACK GLASS INTERIOR PANELS TRADITIONAL LOGSDRIFTWOOD LOGS LED ACCENT LIGHTING CLEAR GLASS BEADS MARTINI FRONT FRONT OPTIONS GRAPHITE NEW BRONZE FOG GRAY CLEAN FACE TRIM GRAPHITE NEW BRONZE FOG GRAY EBONY (GLOSS FINISH)1 STAINLESS STEEL1 BLACK EBONY (GLOSS FINISH)1 1 Available for 42" only. TOUCHSCREEN REMOTE Features: on/off, flame height adjustment, fan speed, lights adjustment, thermostat mode, room temperature readout, child lock, timer mode, battery backup, cold climate mode, power vent, wall docking station (fan, lights and power vent are dependent on your fireplace). CONTROLS INTELLIFIRE APP All the features of a remote control with an app installed on your smart device. Monitor your fire from anywhere or even control it with the sound of your voice. IntelliFire is compatible with voice assistants Amazon Alexa and Google Assistant. WIRELESS WALL SWITCH Features: on/off, battery strength indicator, cold climate mode MODEL FRONT WIDTH (A) HEIGHT (B)DEPTH (C)REAR WIDTH (D)GLASS SIZE (E X F)BTU/HR INPUT ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING ACTUAL FRAMING COSMO 32”36" [914] 37" [940] 38-1/16" [967] 36-1/2" [927] 17-3/4" [451] 17-3/4" [451] 25-3/4" [654] 37" [940] 27-1/4" x 15-1/4" [692 mm x 387] 19,000 [NG] 16,500 [LP] COSMO 36"41" [10419] 42" [1067] 33-11/16" [856] 32-3/4" [832] 17-3/4" [451] 17-3/4" [451] 30-3/4" [781] 42" [1067] 32-1/4" x 15-1/4" [819 x 387] 20,500 (NG) 19,000 (LP) COSMO 42"48" [1219] 49" [1245] 33-11/16" [856] 32-3/4" [832] 17-3/4" [451] 17-3/4" [451] 37-3/4" [959] 49" [1016] 39" x 15-1/4" [991 mm x 387] 25,250 [NG] 23,500 [LP] Dimensions are in inches and millimeters. Product information is not complete and is subject to change without notice. Product installation must adhere strictly to instructions shipped with product. We recommend measuring individual units at installation. NOTE: Combustible material should not cover the face. REFER TO INSTALLATION MANUAL FOR DETAILED SPECIFICATIONS ON INSTALLING THIS PRODUCT. Hearth & Home Technologies® reserves the right to update units periodically. Actual product appearance, including flame, may differ from product images. B A E ELECTRICAL ACCESS GAS LINE ACCESS F C ELECTRICAL ACCESS D HEAT MANAGEMENT ACCESS TOP VIEW32" RIGHT VIEWFRONT VIEWLEFT VIEW C B D A H E MEASURE FROM TOP OF FIREPLACE OPENING I F J G FRAMING DIMENSIONS COSMO 42 COSMO 36 COSMO 32 63.8% (NG) 63.0% (NG) 51.1% (NG) EFFICIENCIES EnerGuide (CSA P.4.1-15) EnerGuide is a rating used in Canada to measure annual fireplace efficiency. HNG-1092U-0420 Web: heatnglo.com Phone: (888) 427-3973 E-mail: info@heatnglo.com facebook.com/HeatandGlo twitter.com/HeatandGlo youtube.com/HeatandGlo LIMITED LIFETIME WARRANTY3 The strongest in the industry, Heat & Glo provides a limited lifetime warranty on the most important aspects: firebox and heat exchanger. 3: For full warranty details see heatnglo.com Fireplace glass and other surfaces get extremely HOT and can cause severe burns if touched. Do not remove the protective safety screen from the front of the glass. Keep a safe distance away. To learn more visit www.heatnglo.com/fireplace safety For complete information on this model, please contact us at: DIRECT VENT TECHNOLOGY Direct Vent fireplaces remove 100% of combustion exhaust and odors outside of the home. These sealed fireplaces provide optimal heat, conserve energy and ensure clean, safe indoor air quality. INTELLIFIRE TOUCH IGNITION SYSTEM IntelliFire Touch is our most advanced intermittent-pilot ignition (IPI) system, making operating your appliance simple, smart and safe. Select the IntelliFire app, touch-screen remote control or wireless wall switch for the solution that fits your lifestyle. TECHNOLOGY HEAT MANAGEMENT Solutions to help you manage the heat throughout your house. PASSIVE HEAT™ KIT Passive heat disperses heat naturally without moving parts, allowing TVs to be mounted 12" above the fireplace without a mantel or shelf. SMARTWALL™ TV KIT Design flexibility with automatic fan that allows a TV to be mounted 12” above the fireplace without a mantel or shelf.2 HEAT-ZONE® KIT Reduce wall temperatures and redirect up to 50% of the heat from your fireplace to another room in your home. HEAT OUT® KIT Redirect up to 40% of the heat from your fireplace and direct it outside for comfort year round. OPTIONAL FAN Move heat directly into the room for added comfort. 2 The SmartWall fan will and must run continuously to move the heat away from the area above the fireplace. Also minimum guidelines must be followed: • Minimum of 3" gap between the TV and wall at all angles • Minimum of 24" to side wall • Ambient room temperature 75º F or less • See TV manufacturer’s recommendation for TV operating temperatures • Minimum 60" from the top of the fireplace opening to the ceiling MODEL A B C D E F* G* H I J COSMO 32"8-5/8" [219] 36-1/2" [927] 17-3/4" [451] 37" [940] 31" [787] 0" [0] 0" [0] 1/2" [13] 1/2" [13] 36" [914] COSMO 36"8-5/8" (219) 32-3/4" (832) 17-3/4" (451) 42" (1067) 31" (787) 0" (0) 0" (0) 1/2" (13) 1/2" (13) 36" (914) COSMO 42"8-5/8" [219] 32-3/4" [832] 17-3/4" [451] 49" [1245] 31" [787] 0" [0] 0" [0] 1/2" [13] 1/2" [13] 36" [914] 36" & 42" RIGHT VIEW PRODUCT DIMENSIONS *Clearance to combustibles Google, YouTube and Google Home are trademarks of Google LLC. Amazon, Alexa, and all related logos are trademarks of Amazon.com, Inc. or its affiliates. 1Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 Vent Components CAUTION! Risk of Fire! DO NOT store instruction manuals inside fireplace cavity. High temperatures could cause a fire. INSTALLER: Leave this manual with the appliance, not inside the appliance. CONSUMER: Retain this manual for future reference. Do not store inside the appliance. Hearth & Home Technologies Approved Vent Components This is the list of vent components and termination caps that are approved for use with HHT gas appliances. All caps are not approved for all appliance models. Consult the Appliance Installation Manual for a complete list of vent components approved for the specific model being installed. Follow instructions included with vent components for proper installation. Venting system components have been tested for use with approved HHT Direct Vent appliances. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for per- mits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification of any of the instructions contained here, contact your Hearth & Home Technologies dealer. For the dealer nearest you, please visit www.hearthnhome.com. Table of Contents A. DVP Vent Components Diagrams ...................2 B. SLP Vent Components Diagrams ....................7 C. Power Vent Components Diagrams .................11 D. Coaxial / Colinear Components Diagrams ............14 E. Decorative Terminations / Shrouds .................14 WARNING! Risk of Fire! DO NOT install unapproved vent components! Consult appliance Installation Manual for a list of approved vent components for the specific model being installed. Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/222 Figure 1 DVP Vent Components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 10 in. (254 mm) 1 in. (25 mm) DVP-FS (Ceiling Firestop) DVP45 (45º Elbow) DVP Pipe (see chart) Effective Height/Length 4-7/8 in. (124 mm) (13 mm) 10 in. (254 mm) 1- 1/2 in. (38 mm) 5 in. (127 mm)12 in. (305 mm) UP DVP-HVS (Vent Support) 12 in. (305 mm) 14 in. (356 mm) 1 in. (25 mm) 8 in. (203 mm) 6 in. (152 mm) DVP-WS (Wall Shield Firestop) Finished Height: 19-3/4 in./502 mm UNIV-AS2 (Attic Insulation Shield) Tab=1 in. (25.4 mm) 20-3/4 in. (527 mm) 14 IN. (356 MM) 14 IN. (356 MM) 20 IN. (508 MM) 12 IN. (305 MM)DVP-RDS ROOF DECK INSULATION SHIELD A. DVP Vent Components Diagrams 3Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 A.DVP Vent Components Diagrams (continued) Figure 2 DVP Vent Components DVP-HPC1 Can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. * Center of the horizontal vent pipe to the vertical measuring surface. DVP-HPC2 Can adjust 4-1/8 in. (6-3/8 to 10-1/2) Term Cap Minimum Effective Length Maximum Effective Length Trap1 3-1/8 in. 4-5/8 in. 79 mm 117 mm Trap2 5-3/8 in. 9-3/8 in. 137 mm 238 mm 15-1/8 in. (384 mm) 12 in. (305 mm) Heat Shield Max Effective Length *5 in. (127 mm) 8 in. (203 mm) Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/224 Figure 3 DVP Vent Components A. DVP Vent Components Diagrams (continued) 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) RF6Roof Flashing 31 in.(787 mm) 24-5/8 in.(625 mm) 13-1/4 in.(337 mm) RF12 Roof Flashing Cap ShieldDRC-RADIUS 13-7/8 in. (352 mm) 9-1/2 in. (241 mm) 14 in. (356 mm) COOL-ADDMCap Shield 11-5/8 in. (295 mm) 5-3/4 in. (146 mm) 7-1/8 in. (181 mm) 12-1/8 in. (308 mm) DVP-BEK2DVP-HPC Cap Brick Extension 13-7/8 in. (352 mm) 5 in. (127 mm) 11-7/8 in. (302 mm) DVP-TRAPFL Flashing 26 in. 660 mm DVP-HSM-B Extended Heat Shield TRAP-VSSVinyl Siding Shield 12 IN. (305 mm) 2-3/8 IN. (60 mm) 7 IN. (178 mm) 15/16 IN.(24 mm) 5Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 Figure 4 DVP Vent Components DVP-TB1 Basement Vent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm)17-3/4 in. (451 mm)10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in.(133 mm) 12-1/2 in.(318 mm) DVP-TVHW VerticalTermination Cap (Highwind) 14 in. (356 mm) 12 in. (305 mm) 12-1/8 in. (314 mm) 7-1/8 in. (181 mm) 8-3/4 in. (222 mm) 1-5/8 in. (41 mm) 16-7/8 in. (429 mm) DVP-HPC High Performance Cap 6 in. 152 mm A. DVP Vent Components Diagrams (continued) Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/226 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3°87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm DVP-HRC-ZC-SS Figure 5 DVP Vent Components A. DVP Vent Components Diagrams (continued) 7Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 B. SLP Vent Components Diagrams Figure 6 SLP Series Vent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm9-1/4 in. 235 mm SLP45 45° Elbow SLP90 90° Elbow Effective Height/ Length SLP PIPE SLP-HVS Horizontal Pipe Support SLP-FS Ceiling Firestop SLP-WS Wall Shield Firestop DVP-SLP24 Adapter 6-1/2 in. 165 mm 25-3/16 in. 640 mm 8-1/16 in. 205 mm 10-7/8 in. 276 mm 8-7/8 in. 225 mm 1-1/2 in. 38 mm 8-11/16 in. 220 mm 8-11/16 in. 220 mm 1-1/2 in. 38 mm 12 in. 305 mm 12 in. 305 mm 5-1/2 in. 146 mm Effective Height/Length Pipe inches mm SLP4 4 102 SLP6 6 152 SLP12 12 305 SLP24 24 610 SLP36 36 914 SLP48 48 1219 SLP6A 2 - 6 51 - 152 SLP12A 2 - 12 51 - 305 SLP-FLEX-3 36 914 SLP-FLEX-5 60 1524 SLP-FLEX-10 120 3048 Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/228 B. SLP Vent Components Diagrams (continued) Figure 7 SLP Series Vent Components SLP-WT-BK Wall Thimble-Black SL-2DVP Adapter 26 in. 660 mm DVP-HSM-B Extended Heat Shield SLP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required. Term Cap Minimum Effective Length Maximum Effective Length Trap1 3-1/8 in. 4-3/4 in. 79 mm 121 mm Trap2 5-1/4 in. 9-1/4 in. 133 mm 235 mm 12 in. (305 mm) 14-7/16 in. 367 mm 14-7/16 in. 367 mm 2-5/16 in. 59 mm 3-15/16 in. (101 mm) 6-11/16 in. (169 mm) 8 in. (203 mm) 3-15/16 in. (101 mm) 3-13/16 in. (97 mm) 5-1/16 in. (128 mm) 6-3/8 in. 163 mm 4-3/16 in. 106 mm 4-5/8 in. 117 mm 5-1/16 in. 128 mm8-1/8 in. 206 mm DVP-2SL Adapter 4 in. 102 mm 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) SLP-HRC-SS Horizontal Termination Cap 12-5/8 IN. (321 mm) 12-5/8 IN. (321 mm) 20 IN. (508 mm) 10-5/8 IN. (270 mm) SLP-RDS ROOF DECK INSULATION SHIELD * Center of the horizontal vent pipe to the vertical measuring surface. Heat Shield Max Effective Length *5 in. (127 mm) 8 in. (203 mm) 9Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 13 in. 330 mm 13 in. 330 mm 1-5/16 in. 34 mm10-9/16 in. 269 mm 14 in. 356 mm 12-1/2 in. 318 mm 12 in. 305 mm SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLK-SNKD Snorkel Termination Cap SLP-TVHW Vertical Termination Cap 13-1/2 in. 343 mm 28-1/2 in. 724 mm 10-11/16 in. 271mm 17-7/8 IN. 454 mm 7-3/8 IN. 187 mm 14 IN. 356 mm 12 IN. 305 mm SLP-TB1 Basement Vent Cap 4-3/4 in. 121 mm 4-1/8 in. 105 mm 6 IN.152 mm SLP-FLEX-TRAP Horizontal Termination Kit 14-1/16 IN. 357 mm 15-1/16 IN. 383 mm 10-1/16 IN. 256 mm 9 IN. 229 mm 9-7/16 IN. 240 mm 14-1/16 IN. 357 mm Figure 8 SLP Series Vent Components B. SLP Vent Components Diagrams (continued) Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/2210 Figure 9 SLP series Vent Components B. SLP Vent Components Diagrams (continued) SLP-HHW2 Horizontal High Wind Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) 11Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 Required Wire Harness DESCRIPTION PART NUMBER 10 FT PV Wire Harness PVI-WH10 20 FT PV Wire Harness PVI-WH20 40 FT PV Wire Harness PVI-WH40 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 Note: Wire harnesses required to power the PVLP-SLP connect to the appliance and are ordered separately from PVLP-SLP. Contact your dealer to order. Depending on the control system of the appliance, requirements vary. See below. Components are ordered separately from the power vent. Contact your dealer to order. For Appliances with an IntelliFire or IntelliFire Plus Control System: A PV-IPI-CK be installed on this appliance. Figure 10 PVLP-SLP Vent Components PVLP-HS Heat Shield 14 IN. 356 mm 15-1/2 IN. 394 mm 11-1/2 IN. 292 mm 8 IN. 203 mm 4-3/8 IN. 112 mm 10 IN. 254 mm 5-1/4 IN. 135 mm 2-1/4 IN. 57 mm 9-1/2 IN. 241 mm 4-3/4 IN. 121 mm 2-1/4 IN. 57 mm 1-1/2 IN. 38 mm 6-1/4 IN. 159 mm Front View Top View Side View Note: A PVLP-HS heat shield is available and sold separately. Use if the PVLP-SLP is installed in a high traffic area. PVLP-BEK Brick Kit PVLP-SLP Power Vent Low Profile For Appliances with an IntelliFire Touch Control System: The PVLP-SLP requires one of the following options to be installed on this appliance. Option A: IFT-RC400 and/or IFT-WFM, IFT-ACM and IntelliFire App that can be downloaded from the app store. OR Option B: IFT-RC150, IFT-ACM, IFT-WFM and an IntelliFire App that can be downloaded from the app store. These accessories are purchased separately from the PVLP-SLP. Contact your dealer to order. C. Power Vent Components Diagrams Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/2212 Figure 11 PVV-SLP Vent Components 13-5/8 IN. 13-11/16 IN. 1-3/4 IN. 4 IN. 5-7/8 IN.3-11/16 IN. 12-1/8 IN. TOP VIEW SIDE VIEW Required Wire Harness and PVV-SLEEVE Lengths Available Part Number 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness PVI-WH20 40 ft. PV Wire Harness PVI-WH40 60 ft. PV Wire Harness PVI-WH60 80 ft. PV Wire Harness PVI-WH80 100 ft. PV Wire Harness PVI-WH100 Description Part Number 12 in. Wire Harness Sleeve PVV-SLEEVE-12 48 in. Wire Harness Sleeve PVV-SLEEVE-48 PVV-SLP Vertical Power Vent Note: A wire harness is required to power the PVV-SLP and connect it to the appliance. It is ordered separately from the PVV-SLP. Contact your dealer to order. Depending on the control system of the appliance, requirements vary. See below. Components are ordered separately from the power vent. Contact your dealer to order. For Appliances with an IntelliFire or IntelliFire Plus Control System: Note: The PVV-SLP requires a PV-IPI-CK be installed on this appliance. The PV-IPI-CK is ordered separately from the PVV-SLP. Contact your dealer to order. Note: The PVV-SLEEVE-12 and/or PVV-SLEEVE-48 is required to be installed with the PVV-SLP. It is ordered separately from the PVV-SLP. Contact your dealer to order. For Appliances with an IntelliFire Touch Control System: Note: The PVV-SLP requires one of the following options to be installed on this appliance. Option A: IFT-RC400 and/or IFT-WFM, IFT-ACM and IntelliFire App that can be downloaded from the app store. OR Option B: IFT-RC150, IFT-ACM, IFT-WFM and an IntelliFire App that can be downloaded from the app store. These accessories are purchased separately from the PVV-SLP. Contact your dealer to order. C. Power Vent Components Diagrams (continued) 13Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/22 Figure 12 PVI-SLP-B Vent Components Optional Wire Harness DESCRIPTION PART NUMBER 10 FT PV Wire Harness PVI-WH10 20 FT PV Wire Harness PVI-WH20 40 FT PV Wire Harness PVI-WH40 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVI-SLP-B Power Vent Inline SLP-LPC SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Note: Wire harnesses required to power the PVI-SLP-B connect to the appliance and are ordered separately from PVI-SLP-B. Contact your dealer to order. 16 IN. 406 mm 15 IN. (381 mm) 16-11/16 IN. (424 mm) 9-3/16 IN. (233 mm) 4-1/2 IN. 114 mm 16-11/16 IN. 424 mm 13-5/8 IN. (346 mm) 12-1/2 IN. (318 mm) 12-1/2 IN. 318 mm 20-3/4 IN. 527 mm 13-5/8 IN. 346 mmEFFECTIVE LENGTH 32 IN. (813 mm) MIN. 35 IN. (889 mm) MAX. Depending on the control system of the appliance, requirements vary. See below. Components are ordered separately from the power vent. Contact your dealer to order. For Appliances with an IntelliFire or IntelliFire Plus Control System: Note: The PVI-SLP-B requires a PV-IPI-CK be installed on this appliance. The PV-IPI-CK is ordered separately from the PVI-SLP-B. Contact your dealer to order. For Appliances with an IntelliFire Touch Control System: Note: The PVI-SLP-B requires one of the following options to be installed on this appliance. Option A: IFT-RC400 and/or IFT-WFM, IFT-ACM and IntelliFire App that can be downloaded from the app store. OR Option B: IFT-RC150, IFT-ACM, IFT-WFM and an IntelliFire App that can be downloaded from the app store. These accessories are purchased separately from the PVI-SLP-B. Contact your dealer to order. C. Power Vent Components Diagrams (continued) Hearth & Home Technologies • Approved Vent Components • 2583-983 Rev. B • 12/2214 LINK-DV30B Flex Liner Kit 768-380A Stainless Steel Flex Pipe DVP-2SL Adapter COAXIAL to COLINEAR VENTING Figure 13 Coaxial / Colinear Vent Components D. Coaxial / Colinear Components Diagrams E. Decorative Terminations / Shrouds Only use listed decorative termination caps/shrouds with Hearth & Home Technologies approved venting systems. This applies to both DVP and SLP venting systems. Decorative Terminations Caps/Shrouds DTO134 Octagon Decor Cap DTO146 Octagon Decor Cap DTS134 Square Decor Cap DTS146 Square Decor Cap LDS33 Decor Shroud 36 x 36 LDS46 Decor Shroud 48 x 72 LDS-BV Decor Shroud 26 x 26 DV-46DVA-GCL Coaxial/Colinear Appliance Connector 1 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 PVI-SLP-B Power Vent Inline - Installation Instructions - INTRODUCTION The Power Vent Inline (PVI-SLP-B) is certified for use only on fireplaces manufactured by Hearth & Home Technolo- gies with IPI (intermittent pilot ignition) gas controls and is for use only on top-vented applications. Fireplaces equipped with millivolt type gas controls CANNOT use this product. 1 1 Introduction DO NOT DISCARD THIS MANUAL NOTICE • Leave this manual with party responsible for use and operation. DO N O T DIS C A R D • Important operating and maintenance instructions included. • Read, understand and follow these instructions for safe installation and operation. Table of Contents 1 Introduction A. Components and Service Parts List ..................2 B. Installation of PVI-SLP-B ..........................3 2 Vent Information and Diagrams A. Installation of Vent Pipe ...........................4 B. Vent/Pipe Regulations .............................4 C. Venting Length - Model Categories and Length Requirements by Termination Type .................11 D. Vent Termination Minimum Clearances ..............14 3 Framing and Clearances A. Framing and Clearances .........................15 4 Electrical Information A. Wiring the Appliance for the PVI-SLP-B with IntelliFire® or IntelliFire® Plus (IPI) Controls ....................19 B. Wiring the Appliance for the PVI-SLP-B with IntelliFire Touch® (IFT) Controls ............................24 5 Operating Instructions A. Installation Inspection ............................29 B. Vacuum Switch Orientation .......................29 C. Setting the PVI-SLP-B Baffle Adjustment ............29 D. Power Vent Operating Instructions .................30 E. Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 F. PVI-SLP-B Troubleshooting .......................32 G. IFT-Controls and PVI-SLP Power Vent Troubleshooting .33 IMPORTANT: Failure to read and follow these instruc- tions may create a possible hazard and will void the fire- place warranty. These instructions must remain with the equipment. CAUTION! Risk of Cuts or Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. Installation of the PVI-SLP-B may be done by a qualified service technician only. Installation MUST comply with lo- cal, regional, state and national codes and regulations. 2 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 BLOWER ASSEMBLY 2196-025 VACUUM SWITCH 2196-326 Figure 1.1 Service Parts A. Components and Service Parts List Service Parts List Replacement parts can be obtained from your dealer. Repair of the Power Vent should only be done by a qualified service technician. Required Wire Harness Lengths Available Part Number 10 ft. PV Wire Harness PVI-WH10 20 ft. PV Wire Harness PVI-WH20 40 ft. PV Wire Harness PVI-WH40 60 ft. PV Wire Harness PVI-WH60 80 ft. PV Wire Harness PVI-WH80 100 ft. PV Wire Harness PVI-WH100 IMPORTANT OPERATIONAL NOTE: When the control being used to run the fireplace is activated, a 120 second delay will occur before ignition occurs. This is to allow a pre-purge by the PVI-SLP-B. If fireplace does not light after 135 seconds, refer to the Troubleshooting section of this instruction for further direction. There will also be a 20 minute post-purge in which the PVI-SLP-B will continue to run after appliance is turned off. Note: The battery back-up and wired wall switch feature of any IPI system are removed when the PVI-SLP-B power vent is installed. The fireplace may no longer be operated with battery back-up and/or a wired wall switch. The PVI-SLP-B operates on 120VAC, 60Hz electrical ser- vice which is supplied at the fireplace junction box. Note: PVI-SLP-B requires special control system configurations: • For IntelliFire® and IntelliFire® Plus models, an RC100, RC200, or RC300 and PV-IPI-CK control system is required for installation (except on PRIMO models). The PV-IPI-CK is sold separately. • For IntelliFire Touch® models, an IFT-ACM and IFT-RC400 are required for installation. The IFT- RC400, which includes the IFT-ACM, will need to be purchased if the appliance is not already equipped with IFT. • The battery-backup feature cannot be used with models configured with the PVI-SLP-B. • The wired wall switch feature cannot be used with models configured with the PVI-SLP-B. • An appliance with PVI-SLP-B installed cannot be operated with battery-backup or a wired wall switch. 3 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 B. Installation of PVI-SLP-B 1. INSTALLATION PRECAUTIONS a. This device must be installed by a qualified installer in accordance with these instructions. b. Safety inspection of the venting system should be performed before and after installation of this power vent. Consult local code officials and follow applicable installation codes. c. DO NOT INSTALL DAMAGED EQUIPMENT OR VENT COMPONENTS. d. Disconnect electrical power supply before making wiring connections. e. Venting of more than one appliance in a common vent system is prohibited. f. Clearances between the vent pipe and combustible materials must be maintained at 1-1/2-inch top, 1-inch sides and bottom. g. All outer pipe joints must be sealed with high tem- perature silicone. See Section 2.A. h. The access panel opening must be located such that access for service and adjustment is available. The NEC requires a minimum of 30 inches of space around the opening and 36 inches in front of the opening to the access panel. Consult officials hav- ing jurisdiction regarding regional requirements. CAUTION! Failure to install, operate, and maintain the power venting system in accordance with manufacturer's instructions will result in conditions which may produce bodily injury and/or property damage. NOTICE: The blower motors present in this Power Vent will generate sound during operation. The effects of the increased sound level can be minimized with careful plan- ning during installation of the system. Locating the Power Vent service access grill in an area remote of immediate living space will reduce the effects of the added sound generated during operation. 2. INSTALLATION GUIDELINES WARNING: RISK OF FIRE AND BURNS. DO NOT install PVI-SLP-B with the access panel facing upward. Overheating may occur. NOTICE: Installation of the PVI-SLP-B in an attic is not recommended in regions where temperatures reach 0°F (-18°C) and relative humidity exceeds 60% simultaneously. Low temperatures and high moisture content may cause the PVI-SLP-B to freeze. a. If the PVI-SLP-B is being installed in a confined space (such as a utility closet, mechanical room or attic space) with a total volume less than 250 cubic feet, an access hole with minimum dimensions of 8 inches by 16 inches will be required directly in front of the access panel. The recommended access hole size is 12 inches by 17 inches. This size will allow full access to the 11 inch x 16 inch access panel on the PVI-SLP-B. See Figure 3.1. The confined space where the PVI is installed, and the space to which the access hole opens, must add up to at least 250 cubic feet. This hole may be covered with a decorative cover as long as the cover has a minimum of 50% open air. If the PVI-SLP-B is being installed in a space greater than 250 cubic feet the access hole is still required, but a solid cover may be used. This also applies to a fireplace chase. The decorative cover CANNOT be located on an outside wall that is open to the environment. b. For installations near loose-fill insulation (such as attics) a minimum clearance of six inches must be maintained between the access panel and the insulation. c. The PVI-SLP-B CANNOT be installed with the access panel facing upward. d. The exit termination of mechanical draft systems shall not be less than seven feet above grade when located adjacent to public walkways. e. A mechanical drafting venting system shall terminate at least three feet above any forced air inlet located within 10 feet. 4 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 2 2 Vent Information and Diagrams A. Installation of Vent Pipe For information on standard procedures for venting the appliance, refer to the "Vent Information and Diagrams" section of the appliance installation manual. For the allowable pipe lengths and elbow combinations for an appliance utilizing the PVI-SLP-B, consult the Power Vent diagrams in the Vent Information and Diagrams sec- tion of the appliance installation manual. The PVI-SLP-B uses SLP pipe (6-5/8 inch) connections for both the inlet and outlet. The following termination caps are available for use with the power vent inline (PVI-SLP-B): SLP-TVHW, SLP-LPC, SLP-TRAP, SLP-HHW2, SLP-HRC-SS, SLP-HRC-ZC- SS, SLP-TB1. Check installation manual for termination caps specifications. In certain cases, a pipe adapter may be used in the vent run. The DVP-2SL adapts from 5 in. / 8 in. DVP series starting collars to 4 in. / 6-5/8 in. SLP series vent pipe. Either SLP or DVP venting may be used throughout the vent run except on certain models that require DVP pipe. See Table 2.1. Refer to Section 2.B for more information regarding venting regulations. SLP pipe may be used on the termination side of the PVI. B. Vent/Pipe Regulations WARNING! Risk of Fire! Maintain minimum pipe length between appliance and PVI- SLP-B on all models. Combustible materials surrounding pipe may overheat. 1. A minimum length of venting is required between the appliance and the PVI-SLP-B. This minimum length requirement varies for the specific appliance. Refer to Table 2.1. for requirements for specific models. Once the minimum length requirement is met, the PVI-SLP- B may be installed at any location within the vent run configuration. 2. A minimum of 18 inches is required between the PVI- SLP-B and the termination cap to allow room for the pipe to go through a wall or roof. 3. If PVI-SLP-B is installed in the vertical position, a mini- mum of two 90 degree elbows and two feet of pipe is required between the appliance and the PVI-SLP-B. 4. Total allowable length decreases by 2 ft. for every 1 ft. of vertical drop. Figure 2.1 High Temperature Silicone Sealant All outer pipe joints must be sealed with high temperature silicone (with a minimum of 300 ºF continuous exposure rating), including the slip section that connects directly to the horizontal termination cap. • Apply a bead of silicone sealant inside the female out- er pipe joint prior to joining sections. See Figure 2.1. OR • Apply aluminum foil tape (300 ºF minimum continuous exposure rating) to the outside of connecting joint after joining sections. On horizontal pipe runs, it is recom- mended that the tape seam is positioned on the bot- tom side of the vent pipe. • Only outer pipes need to be sealed. All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed in this manner, unless otherwise stated. Note: See Table 2.1 for model specific vent requirements. 5 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Table 2.1 WARNING! Risk of Fire! • PVI-SLP-B cannot be installed directly on appliance. The PVI-SLP-B and combustible materials surrounding vent pipe may overheat.• A minimum length run of initial vent pipe is required between the appliance and the inlet of the PVI-SLP-B. The initial minimum vent run requirement varies depending on the specific appliance and its venting configuration. • Some models require DVP Series pipe for the initial minimum vent section directly off the appliance. MODEL MINIMUM VENTING BETWEEN APPLIANCE AND PVI-SLP-B 6000C, 6000CL, 6000CLX (IPI and IFT) 8000C, 8000CL, 8000CLX (IPI and IFT), 6000BEC-IPI PVI installed horizontal orientation: One 90 degree elbow and a total of two feet of straight horizontal or straight vertical SLP pipe. See Figure 2.2 and Figure 2.5. PVI installed vertical orientation: Two 90 degree elbows and a total of two feet straight horizontal or straight vertical SLP pipe. See Figure 2.3, 2.4, 2.6. 6000CMOD, 8000CMOD (IPI and IFT) CD4236, CD4842, CNXT4236, CNXT4842 (IPI and IFT) DBDV36I, DBDV42I, DBDV36PLATI, DBDV42PLATI, MERID36I, MERID42I, MERIDPLA36I, MERIDPLA42I ECLIPSE-32, ECLIPSE-36, EVEREST-B, GDST3831, GDST4336, GDFL4136, GDCR4136,GDCL4136 RCOR-DV36IN, LCOR-DV36IN NDV3630, NDV3933, NDV4236, NDV4842, NDV30-IFT, NDV33-IFT, NDV36-IFT NDV42-IFT NEVO3630, NEVO4236 PEARL36PRIN, PEARL36STIN ALL QUARTZ32, QUARTZ36, QUARTZ42 NNXT3933, NNXT4236, NNXT33-IFT, NNXT36-IFT ST-36TR. ST-36TR, ST-36TRB, PIERI-36TR, PIER-36TRB, LCOR-36TRB, RCOR-36TRB RED40, RED40ST REVO-S21, REVO-H31, ION-S7, ION-H7 ALL COSMO32-IFT, RAVE32-IFT, JADE32IN, SLR32, ALL RAVE3012I, RAVE3012-IFT ALL COSMO36-IFT, COSMO42-IFT, RAVE36-IFT, RAVE42-IFT ALL RAVE4013I, RAVE4013-IFT, ALL JADE42IN, JADE42IL, ALL SLR SL-350TRS, SL-550TRS, SL-750STRS SL-550TR, SL-750TR, SL-950TR SL-550METRO, SL-550-BE-M SL-5, SL-7, SL-9, SL-5F, SL-7F, SL-5F-IFT, SL-7F-IFT, SL-5-IFT, SL-7-IFT, SL-9-IFT SL-3X, SL-5X, SL-7X, SL-9X, SL-3X-IFT, SL-5X-IFT, SL-7X-IFT, SL-9X-IFT ODMEZG-36 MODEL MINIMUM VENTING BETWEEN APPLIANCE AND PVI-SLP-B ALL ESC-42ST PVI installed horizontal orientation: Minimum two feet straight vertical DVP pipe directly off appliance followed by 90 degree elbow and two feet DVP pipe. DVP-2SL or DVP-SLP24 adapter must be located directly between initial DVP pipe and PVI-SLP-B. See Figure 2.2 and Figure 2.5. PVI installed vertical orientation: Minimum two feet straight vertical DVP pipe directly off appliance, followed by two 90 degree elbows and a total of two feet straight horizontal or straight vertical DVP pipe. DVP-2SL or DVP-SLP24 adapter must be located directly between initial DVP pipe and PVI-SLP-B. See Figure 2.3, Figure 2.4, Figure 2.6. ESCAPE-36DV, ESCAPE42DV ALL HEIR36, HEIR42, HEIR50 ALL LUX36, LUX42 ALL CRAVE4836, CRAVE4836ST, CRAVE6048, CRAVE6048ST CRAVE7260, CRAVE7260ST, CRAVE8472, CRAVE8472ST ALL MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST MEZZO60, MEZZO60ST, MEZZO72, MEZZO72ST, ALL ECHEL36IN, ECHEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN ALL TRUE-36, TRUE-42, TRUE-50, CERONA-36, CERONA-42 MARQ36IN, MARQ42IN, MARQ42STIN, ODFORTG-36 PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST PVI installed vertical or horizontal orientation: Minimum three feet of DVP or SLP pipe is required before connecting the PVI-SLP-B system. The 3 foot minimum does not include the factory-installed six inch DVP pipe. B. Vent/Pipe Regulations (continued) 6 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 H1 H2 V2 V1 A DVP-2SL ADAPTER is required in this position in the vent run on certain models. See Table 2.1. Top Vent - Horizontal Termination Figure 2.2 Horizontal PVI Orientation Minimum Maximum H1 + V1 24 in.610 mm See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termination Type."H2 18 in.457 mm V2 0 in.0 mm A minimum of 2 ft. of vertical piping is required between the appliance and the PVI-SLP-B in addition to the minimum venting described above when installing PVI-SLP-B with certain appliance models. See Table 2.1. Note: 1 ft. of vertical drop decreases total allowable length by 2 ft. WARNING! Risk of Fire! Use DVP pipe between appliance and PVI-SLP-B on these models: ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE-50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48, MEZZO48ST, CRAVE6048, CRAVE6048ST, MEZZO60, MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZ- ZO72, MEZZO72ST, CRAVE8472, CRAVE8472ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECHEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN, ODFORTG-36, ODMEZG-36 Combustibles surrounding pipe may overheat. Note: For PRIMO models, see the PRIMO Installation Manual for vent configurations. 7 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 H1 H2 V2 V3 V1 A DVP-2SL ADAPTER is required in this position in the vent run on certain models. See Table 2.1. WARNING! Risk of Overheating! - Minimum inital length of vent pipe required between appliance and vertically positioned PVI-SLP-B. - Must include two 90 degree elbows. NOTICE: If pipe configuration includes a vertical component that goes downward, a vertical component going back upward is not allowed. Figure 2.3 Vertical PVI Orientation Minimum Maximum H1 + V1 + V2 24 in.610 mm See Chart in Section 2.C: "Venting Length - Model Cat- egories and Length Requirements by Termination Type."H2 18 in.457 mm V3 0 in.0 mm A minimum of 2 ft. of vertical piping is required between the appliance and the PVI-SLP-B in addition to the minimum venting described above when installing PVI-SLP-B with certain appliance models. See Table 2.1. V minimum = 2 ft. and V2 + H1 + V1 minimum = 4 ft. for certain appliance models. See Table 2.1. Note: 1 ft. of vertical drop decreases total allowable length by 2 ft. WARNING! Risk of Fire! Use DVP pipe between appliance and PVI-SLP-B on these models: ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE- 50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48, MEZZO48ST, CRAVE6048, CRAVE6048ST, MEZZO60, MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZZO72, MEZZO72ST, CRAVE8472, CRAVE8472ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECHEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN, ODFORTG-36, ODMEZG-36 Combustibles surrounding pipe may overheat. Note: For PRIMO models, see the PRIMO Installation Manual for vent configurations. 8 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 H2 V3 V2 H1 V1 A DVP-2SL ADAPTER is required in this position in the vent run on certain models. See Table 2.1. WARNING! Risk of Overheating! - Minimum inital length of vent pipe required between appliance and vertically positioned PVI-SLP-B. - Must include two 90 degree elbows. Top Vent - Horizontal Termination - (continued) Figure 2.4 Vertical PVI Orientation Minimum Maximum H1 + V1 + V2 24 in.610 mm See Chart in Section 2.C: "Vent- ing Length - Model Categories and Length Requirements by Termination Type." V3 0 in. 0 mm H2 18 457 mm A minimum of 2ft. of vertical piping is required between the appliance and the PVI-SLP-B in addition to the minimum venting described above when installing PVI-SLP-B with certain appliance models. See Table 2.1. V minimum = 2 ft. and V2 + H1 + V1 minimum = 4 ft. for certain appliance models. See Table 2.1. Note: 1 ft. of vertical drop decreases total allowable length by 2 ft. WARNING! Risk of Fire! Use DVP pipe between appliance and PVI-SLP-B on these models: ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE- 42, TRUE-50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48, MEZZO48ST, CRAVE6048, CRAVE6048ST, MEZZO60, MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZZO72, MEZZO72ST, CRAVE8472, CRAVE8472ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECHEL36STIN, ECHEL48IN,ECHEL48STIN,ECHEL60IN,ECHEL72IN, ODFORTG-36, ODMEZG-36 Combustibles surrounding pipe may overheat. Note: For PRIMO models, see the PRIMO Installation Manual for vent configurations. 9 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Top Vent - Vertical Termination H1 V2 V1 H2 A DVP-2SL ADAPTER is required in this position in the vent run on certain models. See Table 2.1. Figure 2.5 Horizontal PVI-SLP-B Orientation Minimum Maximum H1 + V1 24 in.610 mm See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termination Type." V2 18 in.457 mm See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termination Type." HTOTAL 0 0 30% of total vent length allowed in chart: "Venting Length - Model Categories and Length Requirements by Termination Type" in Section 2.C. A minimum of 2ft. of vertical piping is required between the appliance and the PVI-SLP-B in addition to the minimum venting described above when installing PVI-SLP-B with certain appliance models. See Table 2.1. V minimum = 2 ft. and H1 + V1 minimum = 4 ft. with certain appliance models. See Table 2.1. Note: 1 ft. of vertical drop decreases total allowable length by 2 ft. WARNING! Risk of Fire! Use DVP pipe between appliance and PVI-SLP-B on these mod- els: ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE-50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48, MEZZO48ST, CRAVE6048, CRAVE6048ST, MEZZO60, MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZZO72, MEZZO72ST, CRAVE8472, CRAVE8472ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECHEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN, ODFORTG-36, ODMEZG-36 Combustibles surrounding pipe may overheat. Note: For PRIMO models, see the PRIMO Installation Manual for vent configurations. 10 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Top Vent - Vertical Termination - (continued) V3 V2 V1 H1 H2 A DVP-2SL ADAPTER is required in this position in the vent run on certain models. See Table 2.1. WARNING! Risk of Overheating! - Minimum inital length of vent pipe required between appliance and vertically positioned PVI-SLP-B. - Must include two 90 degree elbows. Figure 2.6 Vertical PVI-SLP-B Orientation Minimum Maximum H1 + V1 + V2 24 in.610 mm See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termina- tion Type." V3 18 in.457 mm See Chart in Section 2.C: "Venting Length - Model Categories and Length Requirements by Termina- tion Type." HTOTAL 0 in.0 in.30% of total vent length allowed in chart: "Venting Length - Model Categories and Length Require- ments by Termination Type" in Section 2.C. A minimum of 2ft. of vertical piping is required between the appliance and the PVI- SLP-B in addition to the minimum venting described above when installing PVI-SLP-B with certain appliance models. See Table 2.1. V minimum = 2 ft. and v2 + H1 + V1 minimum = 4 ft. for certain appliance models. See Table 2.1. WARNING! Risk of Fire! Use DVP pipe between appliance and PVI-SLP- B on these models: ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE-50, CERONA-36, CE- RONA-42, MEZZO36, MEZZO36ST, CRAVE4836, CRAVE4836ST, MEZZO48, MEZZO48ST, CRAVE6048, CRAVE6048ST, MEZZO60, MEZZO60ST, CRAVE7260, CRAVE7260ST, MEZZO72, MEZZO72ST, CRAVE8472, CRAVE8472ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECHEL36STIN, ECHEL48IN, ECHEL48STIN, ECHEL60IN, ECHEL72IN, ODFORTG-36, ODMEZG-36 Combustibles surrounding pipe may overheat. Note: For PRIMO models, see the PRIMO Installation Manual for vent configurations. 11 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 HEAT & GLO HEATILATOR Category 0 Category 0 &1 Category 0, 1 & 2 Category 0,1, 2 & 3 Category 0 & 1 Category 0 Category 0, 1 & 2 Category 0, 1, 2 & 3 REVO-S21 SL-550TR SL-750TR SL-950TR ALL SLR COSMO42-IFT COSMO36-IFT RAVE3012I RAVE3012-IFT RAVE32-IFT ION-S7 ION-H7 NDV3630 NDV3933 NDV4236 NDV4842 NDV30-IFT NDV33-IFT NDV36-IFT NDV42-IFT ALLRAVE4013i RAVE4013-IFT RAVE36-IFT RAVE42-IFT REVO-H31 SL-350TRS SL-550TRS SL-750TRS RED40 RED40ST CD4236 (IPI and IFT) CD4842 (IPI and IFT) SL-5F, SL-5F-IFT SL-7F, SL-7F-IFT ECLIPSE-32 ECLIPSE-36 SL-5, SL-5-IFT SL-7, SL-7-IFT SL-9, SL-9-IFT SL-3X, SL-5X SL-7X, SL-9X SL-3X-IFT SL-5X-IFT SL-7X-IFT SL-9X-IFT SLR32 COSMO32- IFT 6000C (IPI and IFT) 6000CL (IPI and IFT) 6000CLX (IPI and IFT) 6000BEC-IPI ESC-42ST CNXT4236 (IPI and IFT) CNXT4842 (IPI and IFT) 8000C (IPI and IFT) 8000CL (IPI and IFT) 8000CLX (IPI and IFT) ESCAPE-36DV NEVO3630 NEVO4236 6000CMOD (IPI and IFT) 8000CMOD (IPI and IFT) ESCAPE-42DV NNXT3933 NNXT4236 NNXT33-IFT NNXT36-IFT SL-550METRO SL-550-BE-M TRUE-36 TRUE-42 TRUE-50 GDST3831 GDST4336 GDFL4136 GDCR4136 GDCL4136 HEIR36 HEIR42 HEIR50 ST-36TR ST-36TRB PIER-36TR PIER-36TRB LCOR-6TRB RCOR-36TRB MEZZO60 MEZZO60ST MEZZO72 MEZZO72ST LUX36 LUX42 CRAVE4836 CRAVE4836ST CRAVE6048 CRAVE6048ST MEZZO36 MEZZO36ST MEZZO48 MEZZO48ST EVEREST-B CERONA-36 CERONA-42 CRAVE7260 CRAVE7260ST CRAVE8472 CRAVE8472ST C. Venting Length - Model Categories and Length Requirements by Termination Type The Model Category (0,1, 2 or 3) in Table 2.2 and Table 2.3 corresponds with the number in the shaded area of the Vent Length Requirement Chart In Tables 2.4 and 2.5. Table 2.2 Heat & Glo and Heailator Models Note: The REVO-V12 and ION-V7 are not approved for use with the PVI-SLP-B. Note: For PRIMO models, see the PRIMO Installation Manual for vent configurations. 12 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 MAJESTIC HHT Category 0 & 1 Category 0, 1 & 2 Category 0, 1, 2 & 3 Category 0, 1 & 2 Category 0,1,2 & 3 JADE32IN DBDV36I DBDV42I DBDV36PLATI DBDV42PLATI MERID36I MERID42I MERIDPLA36I MERIDPLA42I MARQ36IN MARQ42IN MARQ42STIN RCOR-DV36IN LCOR-DV36IN ODFORTG-36 QUARTZ32I / QUARTZ32IFT QUARTZ36I / QUARTZ36IFT QUARTZ42I / QUARTZ42IFT JADE42IN JADE42IL ODMEZG-36 PEARL36PRIN PEARL36STIN ECHEL36IN ECHEL36STIN ECHEL48IN ECHEL48STIN ECHEL60IN ECHEL72IN Table 2.3 Majestic and Hearth & Home Technologies (HHT) Models 13 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Vertical Termination Total Venting Length (feet) Includes both horizontal and vertical section of pipe # of Elbows 10 20 30 40 50 60 70 80 90 100 110 120 130 140 1 0 0 0 0 0 1 1 1 1 1 1 1 1 1 2 0 0 0 0 0 1 1 1 1 1 1 1 1 3 0 0 0 0 1 1 1 1 1 1 1 1 4 0 0 0 0 1 1 1 1 1 1 1 1 5 0 0 0 1 1 1 1 1 1 1 1 6 0 0 0 1 1 1 1 1 1 1 7 0 0 1 1 1 1 1 1 1 1 8 0 0 1 1 1 1 1 1 1 These configurations are not allowed.9 0 1 1 1 1 1 1 1 1 10 0 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 12 1 1 1 1 1 1 1 Note: Maximum number of 90 degree elbows allowed = 6. Maximum number of 45 degree elbows = 12. Table 2.5 Allowable Vent Runs - Vertical Termination Horizontal Termination Total Venting Length (Feet) Includes both horizontal and vertical section of pipe # of Elbows 10 20 30 40 50 60 70 80 90 100 110 120 130 140 1 0 0 0 0 0 1 1 1 1 2 3 2 0 0 0 0 0 1 1 1 2 3 3 0 0 0 0 1 1 1 1 2 4 0 0 0 0 1 1 1 2 3 5 0 0 0 1 1 1 1 2 6 0 0 0 1 1 1 2 3 These configurations are not allowed.7 0 0 1 1 1 1 2 3 8 0 0 1 1 1 1 2 9 0 1 1 1 1 1 2 10 0 1 1 1 1 2 3 11 1 1 1 1 1 2 12 1 1 1 1 1 2 Note: Maximum number of 90 degree elbows allowed = 6. Maximum number of 45 degree elbows = 12. Table 2.4 Allowable Vent Runs - Horizontal Termination 14 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 D. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .................................................1.5* Over 8/12 to 9/12 .................................................2.0* Over 9/12 to 10/12 ...............................................2.5* Over 10/12 to 11/12 .............................................3.25 Over 11/12 to 12/12 .............................................4.0 Over 12/12 to 14/12 .............................................5.0 Over 14/12 to 16/12 .............................................6.0 Over 16/12 to 18/12 .............................................7.0 Over 18/12 to 20/12 .............................................7.5 Over 20/12 to 21/12 .............................................8.0 Figure 2.8 Minimum Height From Roof To Lowest Discharge Opening HORIZONTALOVERHANG VERTICALWALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCHIS X/ 12 LOWEST DISCHARGE OPENING 2 FT.MIN.20 INCHES MIN. H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Fire Risk. Maintain vent clearance to combustibles as specified. • DO NOT pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause overheating and fire. WARNING Figure 2.9 Staggered Termination Caps Gas, Wood or Fuel Oil Termination Cap B Gas Termination Cap ** A * *If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover. ** A B 6 in. (minimum) up to 20 in. 152 mm/508 mm 18 in. minimum 457 mm 20 in. and over 0 in. minimum In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap. Refer to the appliance installation manual for information on minimum clearances for vent termination. * H minimum may vary depending on regional snowfall. Refer to local codes. 15 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 A. Framing and Clearances Note: The factory-installed mounting brackets must be used to install the PVI-SLP-B securely to adjacent struc- tures. Chassis Dimensions The dimensions are measured as shown in Figure 3.1. Framing Dimensions WARNING! Risk of fire and burns! DO NOT install PVI- SLP-B with the access panel facing upward. Overheating may occur. Table 3.1 and Figure 3.1 show the clearances required for the PVI-SLP-B. Required clearances are the same for all allowable PVI-SLP-B orientations. Height Width Depth 20-7/8 in.13-5/8 in.12 in. 3 3 Framing and Clearances Table 3.1. Figure 3.1 Dimensions and Minimum Clearances If the PVI-SLP-B is being installed in a confined space (such as a utility closet, mechanical room or attic space) with a total volume less than 250 cubic feet, an access hole with minimum dimensions of 8 inches by 16 inches will be required directly in front of the access panel. See Figure 3.2. The distance between the fresh air access opening and the back of the open air cover MUST be no greater than 1-3/4 inches. See Figure 3.6. The recommended access hole size is 12 inches by 17 inches. This size will allow full access to the 11 inch x 16 inch cover on the PVI-SLP-B. The confined space where the PVI-SLP-B is installed, and the space to which the ac- cess hole opens, must add up to at least 250 cubic feet. The distance between the fresh air access opening and the back of the open air cover MUST be no greater than 1-3/4 inches. See Figure 3.6. The hole may be covered with a decorative cover as long as the cover has a minimum of 50% open air. See Figure 3.8. If the PVI-SLP-B is being installed in a space greater than 250 cubic feet the minimum size access hole is still required, but a solid cover may be used. This also applies to a fireplace chase. See Figure 3.5. The access panel opening must be located such that ac- cess for service and adjustment is available. The NEC requires a minimum of 30 inches of space around the opening and 36 inches in front of the opening to the ac- cess panel. Consult officials having jurisdiction regarding regional requirements. 1-7/16 IN. 10-3/4 IN. 11-5/8 IN. 18-7/8 IN. 13-5/8 IN.TOP 1 IN. MIN. CLEARANCE 32 IN. MIN. 35 IN. MAX. 1 IN. MIN. CLEARANCE SIDE FRAMING WIDTH 13-5/8 IN. FRAMING HEIGHT 20-7/8 IN. ACCESS PANEL 11 IN. 16 IN. 5-3/4 IN. 7-7/8 IN. 4-11/16 IN. 5-7/8 IN. 16 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Figures 3.3 - 3.5 show possible framing techniques. ACCESS PANEL WARNING! Risk of fire and burns! DO NOT install PVI-SLP-B with the access panel facing upward. Overheating may occur. Note: An 8 X 16 inch (minimum dimensions) framed hole is required in front of the access panel. This hole may be covered with an open air louvered cover. The recommended access hole size is 12 inches by 17 inches. This size will allow full access to the 11 inch x 16 inch access panel on the PVI-SLP-B. ACCESS PANEL Figure 3.3 PVI-SLP-B Mounted to Horizontal Surface ACCESS PANEL Note: A framed hole with mini- mum dimensions of 8 inches x 16 inches is required in front of the access panel. This hole may be covered with an open air louvered cover. The recom- mended access hole size is 12 inches by 17 inches. This size will allow full access to the 11 inch x 16 inch access panel on the PVI-SLP-B. Figure 3.4 PVI-SLP-B Mounted to Vertical Surface Figure 3.5 Mount PVI-SLP-B to Chase CHASE APPLIANCE Note: A framed hole is required in front of the access panel. This hole may be covered with an open air louvered cover and must be a minimum of 8 inches x 16 inches. The recommended access hole size is 12 inches by 17 inches. This size will allow full access to the 11 inch x 16 inch access panel on the PVI-SLP-B. Figure 3.2 Access Panel Framing Dimensions 8 IN. MIN. 16 IN. MIN. = OPTIONAL FINISH MATERIAL AROUND ACCESS PANEL FRAMING WIDTH 13-5/8 IN. MIN. TOP 17 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 SHEETROCK ADJUST BRACKET TO SPECIFIED DEPTH LOUVERED OR OPEN AIR WALL COVER 1-3/4 IN. MAXIMUM FROM BACK OF OPEN AIR COVER TO FRESH AIR ACCESS 13-5/8 IN. 8 IN. x 16 IN. MIN. OPENING IN WALL DECORATIVE OPEN AIR COVER NOTE: COVER MUST BE AT LEAST 50% OPEN AIR. Figure 3.6 PVI-SLP-B Mounted with Fresh Air Access Figure 3.8 Requirements for Decorative Cover Installation SCREWS CATCH PLATECATCH PLATE HOLES NOTE: When the PVI-SLP-B is installed in the upside-down, horizontal orientation, the supplied catch plate needs to be mounted onto the cover assembly. Figure 3.7 Mount the Catch Plate Refer to Figures 3.6, 3.7 and 3.8 for installation requirements depending on orientation of the PVI-SLP-B. WARNING! Risk of Fire! DO NOT install PVI-SLP-B with open air cover more than 1-3/4 inches from fresh air access. Power vent could overheat. 18 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 For additional scenarios to attach the PVI-SLP-B, the optional mounting brackets (2196-024) can be used. They can be secured to the side brackets on the PVI- SLP-B using wing nuts (supplied). The brackets can be attached anywhere along these designated holes. See Figure 3.10. The optional mounting brackets may be used when mounting the PVI-SLP-B to a studded wall. See Figure 3.11. Securing the PVI-SLP-B inside a floor joist can be easily done using the side brackets. See Figure 3.12. If the side brackets cannot be used, or additional support is needed, the optional mounting brackets can be used as shown in Figure 3.13. Figure 3.9 Figure 3.10 Figure 3.11 Figure 3.12 Figure 3.13 SCREWS SCREWS SCREWS 19 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 4 4 Electrical Information TO JUNCTION BOX (110V)MODULE FLAME SENSE IGNITER GROUND ORANGE (PILOT) GREEN (MAIN) BROWN BLACK RED BATTERY PACK 6V DC (AA X 4) THERMOSTAT WIRE ASSEMBLY / WALL SWITCH WIRE STEP 2 STEP 1 STEP 4 STEP 5 STEP 3 STEP 7 STEP 6 Figure 4.1 IntelliFire Plus (Black) IPI Module Wiring as Shipped from Factory A. Wiring the Appliance for the PVI-SLP-B with IntelliFire® or IntelliFire® Plus (IPI) Controls NOTICE: The 8K1-PVI control module must be used to integrate the PVI-SLP-B to the fireplace. (The 8K1-PVI is included with the PV-IPI-CK which is sold separately. When installing the PVI-SLP-B on PRIMO models the 8K1-PVI is included with the fireplace.) NOTICE: Electrical wiring must be done in accordance with national, provincial, and/or local electric codes. CAUTION! Risk of shock! Disconnect electrical power from fireplace/power vent before performing any mainte- nance, repair, or electrical wiring. NOTICE: Electrical service of 120 VAC-60Hz must be supplied to the junction box of the fireplace in order for the power vent to operate correctly. REMOVAL OF UNNECESSARY PARTS Refer to the appropriate directions depending on the color of the IPI module (Black or Green.) IntelliFire Plus IPI Module (Black) Refer to Figure 4.1 for steps 1 through 7. The shaded portion corresponding to the numbered step is the task to be performed. 1. Unplug control module power. 2. Detach the white and orange wires from the control module. 3. Detach the remaining harnesses from the control mod- ule. 4. Remove the black control module. This will no longer be needed. 5. Remove and discard battery pack (if present). 6. Unplug wall switch wires (if present). 7. Remove and discard IPI wire harness. 20 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 STEP 1 PLUG-IN REMOTE JUMPER WIRE ORG GR N BR N BR N RED BLK INTERMITTENT PILOT IGNITOR ORG WHT IGNITION MODULE 3 VAC TRANSFORMER VALVE 3 VAC THERMOSTATWIREASSEMBLY STEP 3 STEP 2 STEP 5 STEP 4 STEP 6 Figure 4.2. IntelliFire (Green) IPI Module Wiring as Shipped from Factory IntelliFire IPI Module (Green) Refer to Figure 4.2 for steps 1 through 6. 1. Remove and discard wire harness connecting the valve to the control module. 2. Unhook the 3V transformer and discard. This will no longer be used. 3. Remove and discard battery pack (if present). 4. Detach the white and orange wires from the control module. 5. Remove the green control module. This will no longer be used. 6. Unplug wall switch wires (if present). 21 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 STEP 4 VALVE ORANGE (PILOT) GREEN (MAIN) GROUND WHT AUX RC300 MODULE AUX 1 AUX 2 8K1-PVI TO JUNCTION BOX 110VAC ACCESSORY CABLE ORG TO JUNCTION BOX 110VAC 8K1-PVI WIRE HARNESS BROWN RED STEP 1 STEP 2 STEP 3 STEP 5 STEP 6 STEP 7 Figure 4.3 PVI Wiring - IntelliFire Plus (RC100, RC200, RC300 Controls) NOTICE: When installing the power vent with the MEZZO, ECHELON, and CRAVE models, the LED will need to be disconnected from the AUX2 (factory setting) and moved to AUX1. Plug the power vent system into AUX2. The LED function will only be operational on the HIGH setting. INSTALLATION The type of control used to power the appliance is the de- termining factor in making the appliance compatible with the PVI-SLP-B. • A 7/8 in. diameter hole must be bored in the side of the fireplace outer wrap in which the 5 wires from the power vent will be routed. The hole should be located 2 inches to the side of the junction box and 4-inches up from the base of the fireplace. Intellifire Plus IPI Module (Black) 1. Attach the new 8K1-PVI module to the 6V transformer. 2. Connect the pilot wires (white to S and orange to I) to the 8K1-PVI module. 3. Connect the new Aux RC300 to the 8K1-PVI module. 4. Plug the Aux RC300 into the Junction Box. 5. Attach the 8K1-PVI wire harness to the 8K1-PVI module. Connect green and orange valve wires and reconnect ground wire to chassis. 6. Connect the accessory cable coming from the PVI- SLP-B to the AUX RC300 (AUX 2 port) and the corresponding colored wire on the wire harness. 7. Connect the stepper motor wires to the 8K1-PVI module. 22 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 STEP 4 GROUND WHT AUX RC300 MODULE AUX 1 AUX 2 8K1-PVITO JUNCTION BOX 110VAC ACCESSORY CABLE ORG TO JUNCTION BOX 110VAC 8K1-PVI WIRE HARNESS BROWN RED STEP 2 STEP 3 STEP 5 VALVE ORANGE (PILOT) GREEN (MAIN) STEP 1 STEP 6 Figure 4.4 PVI Wiring - IntelliFire Ignition System IntelliFire IPI Module (Green) 1. Attach the new 8K1-PVI module to the 6V transformer. 2. Connect the pilot wires (white to S and orange to I) to the 8K1-PVI module. 3. Connect the new Aux RC300 to the 8K1-PVI module. 4. Plug the Aux RC300 into the Junction Box. 5. Attach the 8K1-PVI wire harness to the 8K1-PVI module. Connect green and orange valve wires and reconnect ground wire to chassis. 6. Connect the accessory cable coming from the PVI to the AUX RC300 (AUX 2 port) and the corresponding colored wire on the wire harness. 23 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 RED GREEN BLACK NOTE: Use threaded nut to secure accessory cable to power vent. AXIAL FAN QUICK GROUND CONNECT JUMPER WIRE FAN WHITE BROWN HIGH LIMIT SWITCH BLOWER TO PVI CONTROL VACUUM SWITCH JUMPER WIRE Figure 4.5 Internal PVI Wiring 24 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 B. Wiring the Appliance for the PVI-SLP-B with IntelliFire Touch® (IFT) Controls NOTICE: When integrating the PVI-SLP-B onto an ap- pliance with IntelliFire Touch (IFT) controls, the RC400 remote control and the Auxiliary Control Module (IFT-ACM) must be equipped on the appliance. The IFT-RC400 in- cludes RC400 and the IFT-ACM. NOTICE: Electrical wiring must be done in accordance with national, provincial, and/or local electric codes. CAUTION! Risk of shock! Disconnect electrical power from fireplace/power vent before performing any mainte- nance, repair, or electrical wiring. NOTICE: Electrical service of 120 VAC-60Hz must be supplied to the junction box of the fireplace in order for the power vent to operate correctly. REMOVAL OF UNNECESSARY PARTS Refer to Figure 4.6 for steps 1 through 4. Some features may or may not exist on appliance. The shaded portion corresponding to the numbered step is the task to be performed. 1. Unplug control module power. 2. Remove and discard battery pack (if present). 3. Detach wires from 6 pin harness that connect an op- tional appliance on/off control (if present) and discard. 4. Remove jumper/splitter wire (if present) and discard. WARNING Risk of Fire!Explosion Hazard! Failure to follow instructions could result in a fire or explosion. • Power Vent must be paired to IFT-ACM before installation is complete. • If you have 120 VAC Power & Gas to applance: - Immediately after connecting the PVI-WH connector to the IFT-ACM, the IFT control must be paired to recognize the Power Vent as part of the control configuration. - Appliance and Power Vent function must be verified before installation is complete. - Consult installation manuals for details. • If you DO NOT have 120 VAC Power & Gas: - DO NOT connect PVI-WH connector to IFT- ACM. - Disconnect 6V power to lock-out appliance. 25 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 FLAME SENSE IGNITER TO JUNCTION BOX 110-120 VAC FAN 110-120 VAC LED CONTROL RF MODULE IS BRN ORANGE (PILOT) IFT-RC400 REMOTE CONTROL GRN/WHT/BLK RED/BLK IFT-RC150 WIRELESS WALL SWITCH (OPTIONAL) (OPTIONAL) WIRE ASSEMBLY MODULE RESET SWITCH (OPTIONAL ON SOME MODELS ONLY) SPLITTER BLKRED ADAPTER 6V DC BATTERY PACK BLK RED 6 PIN BLK RED GREEN (MAIN)RED/BLK (OPTIONAL) APPLIANCE ON/OFF CONTROL BRN BLK STEP 1 STEP 2 STEP 4 STEP 3 Figure 4.6. IFT-RC400 Wiring Diagram without Power Vent 26 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Installation Steps: If the appliance is equipped with an IFT-ACM, proceed to step 10. If not, proceed to next step. 5. Locate the IntelliFire Touch electronic control module (IFT-ECM) in the control cavity of the appliance and move the three-position switch to the OFF position. See Figure 4.7. 6. Remove protective rubber cap from connector on the top of the IFT-ECM. See Figure 4.7. Figure 4.7. IFT-ECM 8. Connect the IFT-ACM to the IFT-ECM by aligning the pins and tabs and pushing the IFT-ACM into the IFT- ECM until both tabs latch in place. Ensure the IFT- ECM and IFT-ACM are aligned with each other and fastened securely. See Figure 4.8. Figure 4.8. Connecting IFT-ACM and IFT-ECM WARNING! Risk of Shock! DO NOT touch male pins. Leave rubber cap on all ports unless port is being con- nected to a load. 9. The IFT-ACM can provide power to HHT approved kits including fan, lights and power vent. • To connect a fan kit to the IFT-ACM, insert the three prong male plug from the fan into the re- ceptacle located on the right side of the IFT-ACM. See Figure 4.9. • To connect a light kit to the IFT-ACM, remove pro- tective rubber cap labeled ‘LIGHTS’ and connect to the female cord that was supplied in your lights kit into the three male pins on the IFT-ACM. See Figure 4.9. • To connect a power vent kit to the IFT-ACM, re- move protective rubber cap labeled ‘AUX’ and connect to the female cord of the PVI-WH wire harness into the three male pins on the IFT-ACM. See Figure 4.9. Figure 4.9. Fan, Lights and Power Vent Connection WARNING! Risk of Shock! DO NOT touch male pins. Leave rubber cap on all ports unless port is being con- nected to a lead. POWER CORDPOWER CORD FANFAN POWERPOWER VENTVENT LIGHTSLIGHTS 10. Refer to wiring diagram with Power Vent to make re- maining connections. See Figure 4.10. 7. Attach velcro included with the IFT-ACM to the bottom of the ACM. See Figure 4.8. ATTACH VELCRO Note: It will be necessary to re-pair the remote after installing HHT approved options to the appliance. Refer to Section 4C for pairing the remote. 27 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 STEP 13 STEP 11 STEP 12 STEP 14 BRN FLAME SENSE IGNITER TO JUNCTION BOX 110-120 VAC FAN 110-120 VAC LED CONTROL RF MODULE ADAPTER IS 6 PIN RED BLK ORANGE (PILOT) GREEN (MAIN) GRN/WHT/BLK RED/ BLK RED/ BLK (OPTIONAL) (OPTIONAL) IFT-RC400 REMOTE CONTROL REDBLK BRN BRN JUMPER WIRE WIRE ASSEMBLY MODULE RESET SWITCH (OPTIONAL ON SOME MODELS ONLY) ACCESSORY CABLE POWER VENT Figure 4.10. IFT-RC400 Wiring Diagram with Power Vent 11. Attach jumper wire included in manual bag of Power Vent between black wire on 6 pin harness and red wire on accessory cable. See Figure 4.10. 12. Attach brown wire from 6 pin harness to brown wire on accessory cable. See Figure 4.10. 13. Plug (3) connector plug on accessory cable into Pow- er Vent port on IFT-ACM. See Figures 4.9 & 4.10. 14. Plug harness from IFT-ACM to junction box. This will already be plugged in if equipped on appliance, or it is included in the IFT-ACM kit if the appliance is not equipped with an IFT-ACM 15. Restore power to the control module. • Power Vent must be paired to IFT-ACM before installation is complete. • If you have 120 VAC Power & Gas to applance: - Immediately after connecting the PVI-WH connector to the IFT-ACM, the IFT control must be paired to recognize the Power Vent as part of the control configuration. - Appliance and Power Vent function must be verified before installation is complete. - Consult installation manuals for details. • If you DO NOT have 120 VAC Power & Gas: - DO NOT connect PVI-WH connector to IFT- ACM. - Disconnect 6V power to lock-out appliance. Failure to follow instructions could result in a fire or explosion. WARNING! 28 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 C. Pairing or Re-Pairing the IFT-RC400 to the Electronic Control Module (IFT-ECM) WARNING! After installation of Power Vent components, the RC400 and IFT-ECM MUST BE Re-Paired for safe operation. CAUTION! Risk of Burns! DO NOT program the IFT Remote Controls to the IFT-ECM when flame or cold climate fuction is on or when appliance is hot. 1. On the IFT-ECM, move the ON/OFF/REMOTE switch to the REMOTE position. The green LED will blink three times. A few seconds later, an audible “beep” will occur to indicate that the system is ready. Note: If the green LED continues to blink slowly (system is searching for a clear channel), wait until it stops before proceeding to step 2. 2. Locate the pairing hole on the IFT-ECM. See Figure 4.11. Using a paper clip or similar item, press and release the pairing button. The IFT-ECM will “beep” once and the green LED will blink for 14 seconds. During the 14 seconds, it is normal for installed accessories such as lights, fan, and Power Vent to energize momentarily. While the green LED on the IFT-ECM is blinking, tap anywhere on the gray indicator bar located at the top of the IFT-RC400 screen. Tap on the pairing function as shown in Figure 4.12. If the IFT-RC400 has been paired successfully to the IFT-ECM, a double audible ‘beep” will be heard from the IFT-ECM. Note: If the RC400 displays the 'Now pairing remote to product' display as shown below before able to reach the diagnostic menu on remote, you must repeat the process as follows; A. Remove one battery from the RC400. B. Press the pairing button on the IFT-ECM. C. Quickly install the battery into the RC400. D. As soon as the main screen appears, tap on the RC400 gray indicator bar. Then immediately tap the pairing icon. Successful pairing will be indicated by a double beep from the IFT-ECM. 3. If the pairing is unsuccessful, repeat steps 1 & 2. Figure 4.11. Pairing IFT-ECM REMOTE POSITIONREMOTE POSITION PAIRING HOLEPAIRING HOLE GREEN LEDGREEN LED Figure 4.12. IFT-RC400 Wall Mount / Pairing Screen NOTE: Refer to Operating Guide and Troubleshoot- ing Section of IFT-RC400 Installation Manual for Operation and Maintenance Sections of Remote Control. Note: If additional components are added such as blowers, lights or Power Vent after initial pairing, the pairing process must be repeated again to detect additional components. 29 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 A. Installation Inspection 1. Follow safety inspection procedures recommended by national, provincial, and/or local codes. 2. Be certain all electrical connections are properly made and secure. 3. Visually inspect the vent system and determine that there is no flue gas spillage, blockage or restriction, leakage, corrosion or other unsafe deficiencies. B. Vacuum Switch Orientation The vacuum switch must be installed on a vertical plane for proper function. If the PVI-SLP-B is mounted in a verti- cal position, the vacuum switch needs to be moved from its place in Figure 5.1 to the location shown in Figure 5.2. To do this, loosen and remove the two nuts securing it to the inside wall of the PVI-SLP-B. Move and secure the vacuum switch onto the adjacent wall using the two bolts that are sticking out of the surface. Be sure that the tube running from the vacuum switch to the motor is not pinched closed. 5 5 Operating Instructions C. Setting the PVI-SLP-B Baffle Adjustment The PVI-SLP-B has a baffle adjustment which must be set during the Installation Inspection. This baffle adjust- ment is located alongside the motor. See Figure 5.3. The baffle adjustment is measured using the holes on the indicator bar of the PVI-SLP-B baffle. See Figure 5.4. This bar raises as the baffle is opened and lowers as the baffle is closed. When only one hole is showing, the baffle is closed. When all three holes are visible, the baffle is all the way open. DO NOT TRY TO FORCE IT OPEN ANY FURTHER THAN 1/2 in. When the power vent is located within ten feet of the ap- pliance, there is no limit to the baffle adjustment. If the power vent is located more than 40 feet from the appliance, the flue baffle must remain closed and cannot be adjusted. See Table 3 for limitations to the baffle adjustment. The need to adjust the baffle will depend upon vent run configuration and burner flame characteristics. Next to the bolt used for baffle adjustment is an indicator bar. • If the burner flames are short, active, and jumping – turn the bolt clockwise (open). Check the burner flames and adjust the baffle again as necessary until the flames are stable, strong, and steady. • If the burner flames are tall, lifting, floating, and ghost- like, the baffle is too open and MUST be closed (turn bolt counter-clockwise). • If the pilot continously sparks and does not become steady, the baffle may need to be opened. The requirements in table 3 must still be met. Figure 5.1 Switch Position for Horizontal Installation Figure 5.2 Switch Position for Vertical Installation CAUTION! Risk of electrical shock! DO NOT allow 120VAC wires to contact hot metal surfaces. Use sup- plied wire ties to bundle wires away from flue pipe, fan housing and other metal surfaces. ZIP TIE ZIP TIE CAUTION! Risk of overheating! The baffle must re- main fully closed when using the PVI-SLP-B with the PRI- MO models. See PRIMO Installation Manual for details and PRIMO48/PRIMO48ST exception. PRIMO MODELS ONLY: 30 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Figure 5.3 Baffle Adjustment Location ADJUSTMENT BOLT INDICATOR BAR INDICATOR BAR ADJUSTMENT HOLES Figure 5.4 Baffle Adjustment D. Power Vent Operating Instructions After installation of the power vent, follow the operation instructions below for the type of control system/remote control used (IPI Plus/RC300, IFT/RC400/RC150. IPI Plus/RC300 1. Turn the remote "ON". Note: During the period of operation after turning the fireplace "ON", there will be a delay (approx. 120 seconds) before the fireplace ignites. This is due to the time neces- sary for the fan to reach operating speed and to remove any gases from the combustion chamber. 2. After turning the remote to the "ON" position, if the fire- place does not turn on, turn the remote to "OFF" refer to the troubleshooting section. 3. Turn the remote to "OFF" to turn off the burner. The power vent will continue to run for 20 minutes. Distance from PVI-SLP-B to Appliance Maximum AllowableBaffle Setting 2-15 ft.3 holes visible 16-39 ft.2 holes visible Greater than 40 1 hole visible Table 3. IFT/RC400 1. Touch screen on RC400 to wake up. 2. Touch 'Turn Flame On'. 3. Observe touch screen - if system is configured properly for Power Vent Operation, a 2 min countdown timer will be displayed next to 'Turn Flame OFF'. See Figure below. CORRECT PV DISPLAY INCORRECT PV DISPLAY 4. If the RC400 display is correct, the Power Vent will be running and the 2-minute countdown timer will run, after which the pilot will ignite followed by the main burner. 5. Touch 'Turn Flame OFF' on the RC400. The pilot and main will extinguish. The Power Vent will continue to run for 20 min. If RC400 display is incorrect, touch 'Turn Flame OFF' and refer to troubleshooting section. WARNING! After installation of Power Vent components, the RC400 and IFT-ECM MUST BE Re-Paired for safe operation. 31 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 11 INCH X 16 INCH ACCESS PANEL Figure 5.5 Maintenance Access SCREWS (3) NUTS (5) E. Maintenance WARNING! Risk of Shock! Before performing any main- tenance or repair to the power vent assembly, make sure electrical power is disconnected to the fireplace. 1. Vent System: Inspect all components and connections annually. Replace, seal, or tighten pipe connections if necessary. 2. Access Panel: Inspect at least annually. Ensure mesh is free of dust and debris. 3. Motor: The fan motor bearings are sealed and no further lubrication is necessary. To access the motor, vacuum switch or pressure sense tube, refer to Figure 5.5. If the motor needs to be removed, take out the three screws that attach the collar to the wall and the five nuts holding the motor down as shown in Figure 5.6. Figure 5.6 Motor/Blower Service 32 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Symptoms Possible Causes Corrective Action IntelliFire Plus System Main Closes/ Pilot open, 5 seconds later pilot sparking with Blower ON. If condition persists for 60 seconds, 8K-1 locks out with 3 LED alarm. Pilot Rectification Failure 1. Verify that black wire on IPI wire harness is prop- erly grounded to the fireplace chassis. 2. Verify that pilot is not being compromised by draft such that it fails to rectify. With the glass as- sembly in place, verify that the pilot flame is en- gulfing the flame sensing rod on the left side of the pilot hood. With a multi-meter, verify that the current in series between the module and the sense lead is at least 0.14 microamps. 3. Verify that line inlet pressure is within range on rating plate and correct pilot orifice is in pilot. 4. If #1-4 are correct, replace IPI module. Pilot and Main shut down and 8K1-PVI locks out with 4,5, or 6 LED alarm. Blocked Flue/Insufficient Draft 1. Verify the teflon pressure tube is connected be- tween blower impeller housing and vacuum switch. 2. Verify that wiring within PVI is correct and that the blower operates during the ignition command. 3. Verify that the venting is connected and sealed properly. 4. Verify that the vent termination is not blocked. 5. If #1 thru #4 are complete, connect brown and red wires to bypass vacuum switch. If malfunc- tion is corrected, lock-out system until the vacu- um switch can be replaced. Main Closes, 5 seconds later pilot sparking with Blower ON. If condition persists for 60 seconds, 8K-1 locks out with 3 LED alarm. Shorted Pilot Sense 1. Verify that the white sensor lead is properly con- nected to the S-terminal on the module. 2. Check for soot deposits on the pilot sense rod, adjacent shielding, or logs. If so, clean affected parts. 3. Verify that the white sense lead from the pilot is not damaged or melted within the firebox or valve compartment. Replace pilot if damage exists. Main Closes, 5 seconds later pilot sparking with Blower ON. If condition persists for 60 seconds, 8K-1 locks out with 3 LED alarm. Disconnected Pilot Sense Verify that white sensor lead is properly connected to the S-terminal and the orange ignitor lead is con- nected to the I-terminal on the module If given ignition command in both ON and RE- MOTE modes, system immediately locks-out with 3 LED alarm. Does not spark or attempt to ignite. Pre-Existing/False Pilot Flame Check for pre-existing pilot flame. If so, the valve is defective and should replaced. Pilot rectifies, burner begins to light, but has a difficult time fully lighting. Draft from back of firebox is too strong due to power vent. Place ember material along the back side of the ports that are experiencing the difficult lighting. This will block a portion of the strong draft. F. PVI-SLP-B Troubleshooting 33 Hearth & Home Technologies • Power Vent Inline (PVI-SLP-B) Instructions • 2196-902 Rev. S • 7/20 Please contact your Hearth & Home Technologies dealer with any questions or concerns. For the location of your nearest Hearth & Home Technologies dealer, please visit www.hearthnhome.com. Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.hearthnhome.com Symptoms Possible Causes Corrective Action System will not respond to ‘ON’ command. IFT-ECM in lockout with 5 RED:1 GREEN LED Error Code. RC400 shows ‘Call Dealer - Power Vent Error’ Message 1. Power Vent Motor Failure 2. Power Vent Over Heating 3. Power Vent Pressure Switch Open 4. Blocked Flue 5. Insufficient Draft 6. IFT-ECM selector switch in ‘ON’ Mode 7. IFT-ECM not paired to remote and Power Vent, 1. Verify that the wiring within the Power Vent is correct. Verify that the PVI-SLP Cord assembly is correctly connected to the IFT switch wires, and the AUX port on the IFT-ACM. 2. Verify that blower operates during ‘ON’ com- mand. 3. Verify that the PVI-SLP is correctly installed such that it is properly vented and will not over- heat. 4. Verify that venting is connected and sealed properly. Verify termination is not blocked. 5. Verify the Teflon tube between the blower and pressure switch is securely connected. 6. Verify that the ‘ON’ command is provided with IFT-ECM in ‘REMOTE’ mode with approved re- mote control. 7. Re-pair the ECM to the Power Vent. System responds to ‘ON’ command. After PVI-SLP completes 60 second pre-purge, IFT system fails to rectify proven pilot flame. IFT- ECM in lockout with 3 RED:1 GREEN LED. RC400 shows ‘Call Dealer - Appliance safety disabled’ Message Pilot Rectification Failure resulting from: 1. Soot or embers contaminating pilot and burner 2. Shorted/melted pilot white ‘S’ sensor wire 3. Disconnected pilot white ‘S’ sensor wire 4. Excessive draft turbulence acting on the pilot flame 5. Oxidation or resistance on the IPI pilot flame sense electrode 6. Supply gas pressure out of specification 1. Verify that the IPI Pilot is clean. If necessary, remove any soot or ember deposits, and clean/ polish flame sensor electrode with fine steel wool. If sooting is present, determine possible causes to correct issue. 2. Verify that the IPI pilot white ‘S’ wire is securely connected to the IFT-ECM, and is not melted/ pinched/shorted along its length. Replace pilot is damage exists. 3. Verify that the gas supply working inlet pressure is within the specification range. 4. Verify that the black wire on the IFT wiring har- ness is securely attached to the chassis ground. 5. Verify that the pilot flame is igniting easily, and the pilot flame is not compromised by excessive draft. With glass assembly fully installed, verify that the pilot flame is stable and fully engulfing the flame sensor electrode. 6. Verify that the pilot sensor/wire resistance is < 1 ohm. If > 1 ohm, and flame rectification is occur- ring slowly, replace the pilot. Pilot ignites and rectifies flame, but burner fails to light, or does not fully light. Excessive draft.1. Verify that the glass is properly installed and all latches are engaged. 2. Place ember material along the back side of the affected burner ports – that can reduce draft af- fect and promote ignition. G. IFT-Controls and PVI-SLP Power Vent Troubleshooting