HomeMy WebLinkAbout20250271 20 Skyward Dr Site Plan Narrative
Verity Engineering, D.P.C.
P.O. Box 474
Troy, New York 12181
518.389.7200 | verityeng.com
1
EngineeringVerity
Project Narrative
Proposed Warehouse Facility
City of Saratoga Springs, Saratoga County
February 2025
Site Address: 20 Skyward Drive
Saratoga Springs, NY 12866
Tax Map 178.-1-61
Applicant: Munter Land Holdings, LLC
c/o John Munter
881 Murray Road
Middle Grove, NY 12850
Owner: Munter Land Holdings, LLC
c/o John Munter
881 Murray Road
Middle Grove, NY 12850
Design Engineer: Verity Engineering, D.P.C.
P.O. Box 474
Troy, NY 12181
Surveyor: Gilbert VanGuilder Land Surveyor, PLLC
988 Route 146
Clifton Park, NY 12065
Zoning: IND-Gā General Industrial
Proposed use: Industrial-General
Project Overview
The applicant is proposing to construct a ±120,000 sq. ft. single-story principal flex industrial
warehouse building with office on a vacant ±12.4-acre parcel with address 20 Skyward
Drive. The parcel is located in the City of Saratoga Springs, NY (TM#:178.-1-61) and located
in the General Industrial (IND-G) zone and is an allowed use. The development plan includes
other site appurtenances such as storm water management, public and private utility service
connections, parking and loading areas, landscaping, and site lighting. The multi-tenant or
single-tenant structure will incorporate roughly 5%-10% of demised office and the remaining
area dedicated to high-bay industrial warehouse use with multiple loading dock positions
along the west building wall. Typical interior uses could accommodate a wide range of
general manufacturing, wholesaling, storage and distribution of raw material and finished
goods merchandise.
Onsite parking, loading areas and two (2) full access curb cuts are proposed onto Skyward
Drive and are situated at the northern and southern ends of the parcel. The project will
disturb greater than one (1) acre of land and will be subject to a New York State Department
of Environmental Conservation (NYSDEC) Stormwater Discharge Elimination System
(SPDES) regulations for general construction under the current permit (GP-0-25-001).
Runoff from stormwater will be conveyed via sheet flow, closed and an open channel
drainage systems utilizing surface detention and infiltration practices. The site is not located
within a flood plain. The project scope of work entails clearing and grubbing, earthwork
2 V
and grading for the preparation of the building pad, parking, stormwater management areas,
utility installations, building construction, paving, landscaping and lighting. The project will
require site plan approval and a land disturbance permit from the City of Saratoga Springs
Planning Board together with a SPDES permit from NYSDEC.
Description of Existing Site and Use
The subject parcel consists of undeveloped land and is located within and along the eastern
boundary of the Grande Industrial Park, a/k/a TMPL: 178.-1-61,20 Skyward Drive), presently
±12.4 acres in size and wholly located within the General Industrial (IND-G) zone. The parcel
was created as part of an approved subdivision (Project 17-025, Lot #1) is bordered by other
commercial and industrial uses to the north and west with an approved, to be built, 70,000
sq. ft. warehouse directly to the east at 1 Skyward Drive. The parcel was once mined for
sand which ceased circa 1995; evidence of the undulating terrain is visible at the surface.
The parcel has frontage along Geyser Road (County Route 43) and Skyward Drive, a private
roadway together with an eight (8ā) inch D.I.P. water main and a 2ā HDPE low-pressure
sewer main together with other private utilities exist along Skyward Drive. The parcel
contains an ingress/egress easement to the D & H Railroad Co, Inc. near the southern
property line which provides limited access across the subject parcel to the adjacent railroad
property. With exception to the sloping grade difference along the western property due
stemming from past mining activity, the site is absent naturally occurring steep slopes,
wetlands, waterbodies, watercourses and is not located within a 100-year flood plain.
Drainage and Surface Water
Surface runoff from the property currently does not leave the site.
Easements and Utilities
See above: Description of Existing Site and Use above.
Anticipated Impacts on Services:
Traffic
A traffic assessment study dated April 3, 2017 was accepted as part of the original
subdivision approval. It is expected that the proposed building will generate additional traffic
in the AM and PM peak hours as the study suggests in section 5.0 (Sensitivity Analysis).
It should be noted that the build-out of Lot 1 (20 Skyward Drive) is 120,000 sq. ft vs. the
estimated 130,000 sq. ft and Lot 2 (1 Skyward Drive) is approved with 70,000 sq. ft. vs the
estimated105,000 sq. ft. used in the sensitivity analysis. It is estimated that the proposed
use will not have an adverse impact on traffic according to the traffic assessment attached
herewith.
Water and Wastewater
New potable water and sewer connections are required to serve the proposed use. Municipal
water and sewer are available along the Skyward Drive roadway frontage to service the
parcel. No physical extension of municipal water or sewer infrastructure is proposed. The
building is proposed to be equipped with an automatic fire protection system; further
engineering details about fire flow demand and water system flow and pressure will be
provided when tenant-specific fit up requirements are known. Potable water demand is
estimated as follows:
Maximum Daily Flow:
100 employees (emp.) * 15 gallons per emp./day * 80% = 1,200 gallons/day
3 V
Estimated Annual Usage:
1,200 gallons/day * 365 days/yr. * 1 cu. ft./7.48 Gal = ±58,556 Cu. Ft./Year.
Daily sewer flows are expected to be the same.
Fire Protection
The site is served by Saratoga Springs Fire Department Station 2. A fire hydrant exists along
the east side of Skyward Drive approximately 100 ft. northeast of the proposed building. The
driveway access in proximity to the proposed building is a between twenty-four (24) feet
wide ā twenty-six (26) feet wide and is sufficient for fire apparatus equipment.
Municipal Solid Waste
The proposed project will generate additional solid waste that will require disposal to a
landfill and recycling center. Private trash collection contractors will be used to collect and
dispose of the solid waste. Dumpsters will be stored in an appropriately screened enclosure
on the south side of the building.
Impact on Adjacent Property
Noise
Sound levels generated from potential uses are normal and customary to the surrounding
commercial and industrial uses in the IND-G zone and will not have adverse impacts to
adjacent neighbors.
Visual
The project will have no adverse visual impact. The proposed development will not be out of
character compared to the surrounding uses.
Lighting
All light poles will be no taller than 20 ft. and all LED lights will be DarkSky compliant
utilizing sharp-cutoff fixtures which direct light only to targeted areas. A photometric plan
can be found on sheet C-191.
Drainage and Stormwater
Drainage patterns will not be altered from the predevelopment conditions. See: Drainage
and Surface Water above. Site disturbance is greater than one (1) acre and will be subject
to GP-0-25-001 regulations. Stormwater runoff will be conveyed via sheet flow, open and
closed drainage to various infiltration practices. Please reference the sheet C-121 and the
Storm Water Pollution Prevention Plan (SWPPP) for further details. Air Quality
The project will have no adverse effect on air quality.
Odor
The project will have no adverse effect on odors.
Impact to Critical Environ or Archaeologically Sensitive Areas
NYSDEC mapping indicates the presence of rare plants or animals within the project area.
NYSDEC has indicated via letter correspondence attached herewith, dated February 5, 2025,
that the proposed action will likely not result in the taking of threatened or endangered
species due to a lack of suitable habitat on or near the project area.
4 V
A letter of no effect issued by New York State Office of Parks, Recreation and Historical
Preservation on December 17, 2004 is attached herewith stating that no properties,
including archaeological and/or historic places will be impacted by the proposed
development.
Existing and Proposed Building Gross Floor Area
Approximate Total Gross Floor Area (GFA): 120,000 square feet (sq. ft.)
Building Height and Number of Floors
The proposed building will be one (1) story and have a sloped roof pitch with maximum roof
height of less than 50ft.
Miscellaneous Site Information
Parking, Parking Improvements and Site Distance
The Industrial-General use shown on Table 10-C 6.2.6, Off-Street Vehicle and Bicycle Parking
Requirements, requires onsite vehicle and bicycle parking. One (1) vehicle space per 1,000
sq. ft. of gross floor area (GFA) up to 40,000 sq. ft. GFA plus one (1) vehicle space per 2,500
sq. ft. GFA grater than 40,000 sq. ft. GFA for a total of seventy-two (72) required vehicle
spaces. Sixty (60) spaces are proposed inclusive of two (2) EV charging spaces and four (4)
ADA accessible spaces together with ADA van accessibility areas. Fifty seven (57) additional
spaces are proposed as banked parking for future use if required and are incorporated into
the stormwater management design. One bicycle space per 2,500 sq. ft. GFA is required; 38
bicycle parking spaces are proposed. Ample sight distance exists along Skyward Drive at the
proposed access driveways.
Hours of Operation
Specific tenant(s) use(s) is(are) unknown at this juncture; tenants may operate 24 hours per
day Monday through Sunday.
Open Space Preservation/Green Space
The proposed green space is approximately ±41.8%. Construction Sequence and Phasing
The project is intended to be built in a single phase.
Disposal of Chemicals
The operation will not involve the storage of regulated chemicals. The Fertilizers and
pesticides for lawn and landscape treatment will be applied by licensed contractor/personnel
and brought to the site at time of application. Town Communication Impacts
No known communication devices or needs are proposed at this time. Variances/Waivers/Referrals
N/A