Loading...
HomeMy WebLinkAbout20250238 67 Putnam Exterior Modifications NOD Page 1 of 1 Tamie Ehinger, Chair Rob DuBoff, Vice Chair Chris Bennett Leslie DiCarlo Jeff Gritsavage Geoff Wood Karen Cavotta, Alternate CITY OF SARATOGA SPRINGS D ESIGN R EVIEW B OARD ❖ City Hall - 474 Broadway Saratoga Springs, New York 12866 Tel: 518-587-3550 x.2517 www.saratoga-springs.org NOTICE OF DECISION In the matter of the application #20250238 67 Putnam St. Exterior Modifications 67 Putnam St. Saratoga Springs, New York 12866 involving Historic review of door replacement and window addition within the Urban Core (UC) District, tax parcel # 165.60-1-62, within the City of Saratoga Springs. In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:  Type II action – exempt from further SEQR review And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the following decision on April 9, 2025:  Approve the plans as submitted or shown on the attached plans Record of vote: motion to approve made by T Ehinger, seconded by G Wood: passed 6 -0 As a result of this decision, the applicant:  may proceed with the plans as approved Please contact the Building Department to verify permit requirements. Chair Received by Accounts cc: Building Department File Accounts Dept. Applicant/Agent Exist'g Metal Framed Opening Exist'g vent Replace Existing Door With Exi5t'g Brick Infill Exi5t'g Windows (typ) Fully Glazed Metal Door. Exist'g Exterior Ductwork Exist'g Louvers (typ) 25' - 3 1/4" 5EC.OND FLOOR S e FIRST FLOOR f k x Exi5t'g MU Fdn GROUND FLOOR ExiSt'g Conc. Fdn ExiSt'g Garage Door PUTNAM 5T 01 - o1, EX15t'g FDG Exi5t'g wall ENTRY LEVEL Lights (typ) Exi5t'g Stone Fdn New -72" YN x 40" H Alum Window - Provide Precast Sill and Brick Soldier Course Above to Match Existing. Align with Window Above. Q 00 0 ti The r ings,plans,specifications and designs contained herein are and shall remain the exclusive property of Charette Associates Architects,P.C.,and cannot be altered,copied,duplicated or used directly or indirectly in whole or in part except with the express written permission of Charette Associates Architects,P.C. Copyright 2025 CHAR T S IATES Project: FACADE MODIFICATIONS No. Description Date SOUTH ELEVATION Cq Owner: TOM ROOHAN Project number 2505 N 76 Cobble Hill Drive Address:67 PUTNAM ST Date 3/20/25 S' K_02Gansevoort,New York N SARATOGA SPRINGS, NY Drawn by LA o Phone(518)265-2628 Checked by LA Scale 1/16" = 1'-0" N co I v t e E e. VIEW OF SOUTH WALL DOOR TO BE REPLACED L. IMRM. tires i'IC^....e tS'' ,,..y•rt"'.. .. ter; e. rl.4Vr'M'plriRfL'L . y L S e' Sitt- i .F ii!!.... LOCATION OF WORK TO BE PERFORMED Project Name: Roohan 63 Putnam 3/14/2025 7:03 AM Frame Set Name: Frame Set 1 Frame Name: Exterior Entrance Metal Group: M450 CG/SS/OG STOPS UP D/S: 1 Frame Type: Standard Required: 1 Panels: 1 Rows: 1 Frame Width: 47 1/2 Frame Height: 81 3/4 Back Member Color: #22 MILITARY BLUE : FLUROPON Face Member Color: #22 MILITARY BLUE : FLUROPON LL O c+n W t Report Provided Courtesy of PartnerPak Studio-5.0.0.122 Page: 1 Of 3 Project Name: Roohan 63 Putnam 3/14/2025 7:03 AM Frame Set Name: Frame Set 1 Frame Name: Interior Door Metal Group: M450 CG/SS/OG STOPS UP D/S: 1 Frame Type: Standard Required: 1 Panels: 1 Rows: 1 Frame Width: 39 1/2 Frame Height: 81 3/4 Back Member Color: #22 MILITARY BLUE : FLUROPON Face Member Color: #22 MILITARY BLUE : FLUROPON 39 1/2 (u.A.FR) 36 E LL 0 t LL I LJ I Report Provided Courtesy of PartnerPak Studio-5.0.0.122 Page: 2 Of 3 Project Name: Roohan 63 Putnam 3/14/2025 7:03 AM Frame Set Name: Fixed frame Frame Name: Fixed Metal Group: M451T CG/SS/OG STOPS UP D/S: 1 Frame Type: Standard Required: 1 Panels: 2 Rows: 2 Frame Width: 72 Frame Height: 42 Back Member Color: #22 MILITARY BLUE : FLUROPON Face Member Color: #22 MILITARY BLUE : FLUROPON 72[unFn; m Ln trJ 1 LL n W Q r N p H a U T T m m Report Provided Courtesy of PartnerPak Studio-5.0.0.122 Page: 3 Of 3 190, 350 AND 500 STANDARD ENTRANCES KAWNEER Single-Source Packages Generate Versatile First Impressions Dallas, lp AN IMMMMM Curtis Culwell Center Garland,Texas ARCHITECT as GLAZING CONTRACTOR PHOTOGRAPHERB&B Glass,Inc.,Dallas,Texas Tough yet attractive, Kawneer's Standard Entrances are designed as a PERFORMANCE single-source package of door,door frame and hardware that is easily To resist both lever arm and torsion forces that constantly act on any adaptable to custom requirements. Designed to complement new or door,all three entrances feature welded corner construction with Sigma remodel construction as well as modern or traditional architecture,they deep penetration and fillet welds plus mechanical fastenings at each are engineered,constructed and tested to make a good first impression corner—a total of 16 welds per door. Each door corner comes with a while withstanding the rigors of constant use by occupants and visitors. limited lifetime warranty,good for the life of the door under normal use. It is transferable from building owner to owner and is in addition to the standard two-year warranty covering material and workmanship of each Kawneer door. 1.Thermoplastic GENERAL elastomer weatherstrip in blade stop of frame • Heights vary up to 10';widths range from approximately 3'to 4' jambs,header or transom bar. Door frame face widths range to a maximum of 4",while depths range to b" 2•Integral polymeric fin . Door operation is single-or double-acting with maximum securityattachedtoadjustable astragal,creating an air locks or touch bar panics standard barrier between pairs • Architect's classic 1" round, bent bar push/pull hardware is availableofdoors. in various finishes and sizes T 3.Optional surface- Infill e from 1/4" to 1"applied bottom s rang weatherstrip with flexible blade gasket. Extruded raised lip on threshold to provide FOR THE FINISHING TOUCH continuous contact for bottom weatherstrip. Architectural Class I anodized aluminum finishes are available in clear 4.Standard 1/4"beveled and Permanodic®color choices. glass stops to sheet water and dirt off without leaving residue. Painted finishes, including fluoropolymer,that meet AAMA 2605 are 5.Available in all finishes offered in many standard choices and an unlimited number of specially offered by Kawneer. designed colors. Solvent-free powder coatings add the"green"element with high performance,durability and scratch resistance that meet the standards ECONOMY of AAMA 2604. Kawneer's bulb neoprene weatherstripping forms a positive seal around the door frame and provides a substantial reduction in air infiltration,resulting in improved comfort and economies in heating and cooling costs.The system is wear-and temperature-resistant and Sigma fillet welds top replaces conventional weatherproofing.The bottom weatherstrip and bottom Sigma deep Steel back-up plate penetration plug welds at the interior contains a flexible blade gasket to meet and contact top and bottom the threshold,enhancing the air and water infiltration performance characteristics. 190 NARROW STILE ENTRANCE Is engineered for moderate traffic in applications such as stores, Reinforcing:chann)el * offices and apartment buildings Vertical stile measures 2-1/8",top rail 2-1/4" and bottom rail 3-7/8" Results in a slim look that meets virtually all construction requirements 350 MEDIUM STILE ENTRANCE Provides extra strength for applications such as schools, institutions and other high-traffic applications Vertical stiles and top rails measure 3-1/2" Bottom rail measures 6-1/2" for extra durability 500 WIDE STILE ENTRANCE Creates a monumental visual statement for applications such as banks, libraries and public buildings Vertical stiles and top rail measures 5"; bottom rail measures 6-1/2" Results in superior strength for buildings experiencing heavy traffic conditions Kawneer Company,Inc. Nor GuthToss, A 3 Court kawn er.co C KAW N E E RKawneerCompany,Inc.2012-2019 Technology Park lAtlanta Norcross,GA 30092 kawneer.com Form Number 17-2225.E Permanodic®is a registered r a nmdemarkorKaw"ee,comPe"Y,i"e. ARCHITECTURAL SYSTEMS I ENTRANCES+FRAMING I CURTAIN WALLS I WINDOWS NOVEMBER, 2024 Product Selection Guide EC 97911-330 SWING DOORS - STANDARD ENTRANCES 190 350 500 Product Standard Entrances Standard Entrances Standard Entrances Narrow Stile Medium Stile Wide Stile Catalog Section Entrances Entrances Entrances xda 3 ° Typical 3 ` Detail N a,O O V Q ry N j O C s c3o'y rncw c r 3 Sightline 2-1/8" 3-1/2" 5" O j O rnca c C O N a;Depth 1-3/4" 1-3/4" 1-3/4" O C_ C N M 3 O N d °O Moderate Moderate to High High Aonsa!t Applications Traffic Traffic Traffic No Nii E m g m Infill Options Up to 1"Up to 1"Up to 1" U N O] Cross Rails/Muntins Yes Yes Yesa m 303E aY t Thermal No No No 2 Color Option No No No 190 narrow stile entrance door 350 medium stile entrance door 500 wide stile entrance door offers a slim appearance,features offers a rugged appearance features dual-moment corner dual-moment corner construction features dual-moment corner construction, and it creates a and is designed for applications construction and is designed for monumental visual appearance such as offices, stores and schools,institutions,and other high for banks, libraries or buildings e apartment buildings. traffic conditions. experiencing the heaviest trafficd conditions. Product 3 Description U OC O O. O L 3 c0 rn Testing for m Protective Glazing g Performance o Class/Ratinga t o ASTM E283 ASTM E283 ASTM E283 N Q Dual Moment Corner Dual Moment Corner Dual Moment Corner N O. NC y w 3 Z` Y m 7 3 coi °N Y o Performance Test Standards kawneer.com ADMO04EN C KAW N E E R DESIGN AND PERFORMANCE VERSATILITY WITH UNMATCHED FABRICATION FLEXIBILITY 1Yr ti< TRIFAB°VERSAGLAZE° 450, 451 & 451T (THERMAL) FRAMING SYSTEMS &TRIFAB° 451 UT (ULTRA THERMAL) FRAMING SYSTEM Trifab°VersaGlaze° is built on the proven and successful Trifab°platform—with all the versatility its name implies.There are enough framing system choices, fabrication methods, design options and performance levels to please the most discerning building owner,architect and installer. The 4.5" depth Trifab°VersaGlaze° Framing System family is available with non-thermal, thermal and ultra-thermal performance levels. The ultra-thermal Trifab°451 UT Framing System, is designed for the most demanding thermal performance and employs adual Isolock°thermal break. BKCKAWNEER gadig I AESTHETICS Photography: Ben Gancsos Trifab°VersaGlaze°Framing Systems offer designers a choice of front-,center-, back-or multi-plane glass applications. Structural silicone glazing(SSG)and weatherseal glazing options further expand designers' choice, allowing for a greater range of possibilities for specific project requirements and architectural styles. All systems have a 4-1/2" frame depth;Trifab®VersaGlaze° 450 has 1-3/4" sightlines,while Trifab°VersaGlaze°451/451T and Trifab°451 UT have 2" sightlines. With seamless incorporation of Kawneer entrances or windows, including GLASSvent°visually frameless ventilators,Trifab°framing can be used on almost any project.These framing systems can also be packaged with Kawneer curtain walls and overhead glazing,thereby providing a full range of proven, and tested, quality products for the owner,architect and installer from to o a single-source supplier. ECONOMY Trifab°VersaGlaze°450/451/451 T/451 U T Framing Systems offer a variety of fabrication choices to suit your project: Screw Spline—for economical continuous runs utilizing two-piece vertical members that provide the option to pre-assemble units for efficient handling and installation. available for all Trifab systems) All systems can be flush glazed from either the inside or outside. The weatherseal option provides an Shear Block—for punched openings or continuous alternative to SSG vertical mullions for Trifab° runs using tubular verticals with shear blocks to connect VersaGlaze®450/451/451T. This ABS/ASA rigid polymer horizontal members.(available for 450/451/451T systems) extrusion allows complete inside glazing and creates a flush glass appearance on the building exterior Stick—for fast,easy field fabrication.Continuous sill and without the added labor of scaffolding or swing stages. head receptors are installed with horizontals connected Additionally, high-performance flashing options are to tubular verticals with shear blocks.(available for engineered to eliminate perimeter sill fasteners and 450/451/451Tsystems) associated blind seals. Pre-glazed—The combination of screw spline construction with pre-glazing in the shop accelerates FOR THE FINISHING TOUCHinstallationandreducesfieldlabortimewhileminimizing disruption to the surrounding area or existing tenants. Architectural Class I anodized aluminum and painted Making it an exceptional choice for new or retrofit finishes influoropolymer(AAMA 2605) and solvent- applications, particularly in urban areas or where space free powder coatings (AAMA 2604) offer a variety is limited.(available for 451/451T/451 UT framing) of color choices. IFICKAWNEER PERFORMANCE Kawneer's Isolock°thermal break technology creates U-factor, CRF values and STC ratings for Trifab°framing a composite section, prevents dry shrinkage and is systems vary depending upon the glass plane application. available on Trifab°VersaGlaze°451T. For even greater Project-specific U-factors can be determined for each thermal performance, a dual Isolock°thermal break is individual project. used on Trifab°451 UT. See the Kawneer Architectural Manual or Kawneer.com for additional information.) W Trifab°451 UT uses a dual Isolock°thermal break(right) and features a new high performance sill design,which incorporates a screw-applied end dam (left), ensuring positive engagement and tight joints between the sillALflashingandenddam. PERFORMANCE TEST STANDARDS Thermal simulations showing temperature variations from exterior/cold side to interior/warm side. Air Infiltration ASTM E283 Water AAMA 501,ASTM E331 Structural ASTM E330 Thermal AAMA 1503 Trifab® Trifab®VersaGlaze® Trifab®451UTThermalBreakAAMA505,AAMA TIR-A8 VersaG laze"451 451T Acoustical AAMA 1801,ASTM E1425 aP ne ir-r ar M ur NP as Vr DOLE WARM Front Center Back SSG Weatherseal Multi-Plane Kawneer Company,Inc.2024 Form Number 17-2241.B IC KAW N E E R Technology Park/Atlanta 555 Guthridge Court Norcross,GA 30092 NOVEMBER, 2024 Product Selection Guide 11 EC 97911-330 STOREFRONT FRAMING -THERMAL Trifab®VersaGlaze® Trifab®451UT Trifab®VersaGlaze° Trifab®VersaGlaze® Product 451T Framing System Framing System 601T Framing System 601UT Framing System 2"x 4-1/2") 2"x 4-1/2") 2"x 6") 2"x 6") Catalog Section Framing Framing Framing Framing x Typical 3 Detail N a,O O U 0 N J 2 L o T Storefront Storefront Storefront Storefront Applications Ribbon Windows Ribbon Windows Ribbon Windows Ribbon Windows a Punched Openings Punched Openings Punched Openings Punched Openings m Center,Front, Center Center=0 °Glass Plane Options Back,Multi-Plane Center Front FrontCc3aEa; O` E O C C N 3° Infill Options Up tot-1/8" Up tot-1/8" Up tot-1/8" Up tot-1/8" U {Cp N N t Inside Glazed Inside Glazed Inside Glazed Inside Glazedwccy ; Glazing Options Outside Glazed Outside Glazed Outside Glazed Outside GlazedoE m Isol-ock® Dual Isol-ock® Dual Isol-ock® Dual Isol-ock® M Thermal m Pour and Debridge Pour and Debridge Pour and Debridge Pour and Debridge a w 0 ° y ; 3 SSG Optional No Yes(Front) Yes(Front) 3 2 30JnY L Weatherseal Optional No No No 2 Color Option Yes with Front Stick No No No Integrated Entrance Yes Yes Yes Yes Framing WindoE Integra YesYes Yes Yes Yes d 3 GLASSvent® Yes Yes Yes Yes Integration 0 o Versoleil®Sunshade Yes Yes Yes(Center Only)Yes(Center Only)Integration 0 Z 3 Fabrication Screw Spline,Shear Block, Screw Spline,Shear Block,Screw Spline,Shear Block, Method Stick,Continuous Head and Sill Screw Spline Stick Stick AT x 4-1/2"flush glazed system for AT x 4-1/2"flush glazed system for A 2"x 6"flush glazed system for A 2"x 6"flush glazed system for 1"glass.VersaGlaze®is engineered 1"glass.Engineered to perform to 1"glass.Engineered to perform to 1"glass.Engineered to perform to for design and fabrication versatility current energy code requirements current energy code requirements current energy code requirements with variable glass planes choices, using a dual Isol-ock®thermal using a dual Isol-ock®thermal using a dual Isol-ock®thermal g Product SSG or Weatherseal options, break. break. break. e Description Isol-ock®thermal break option and t E four types of fabrication. 0 N 2N C z Y Testing for Protective Glazing Y ` o AAMA 501.1,AAMA 507, AAMA 501,AAMA 505, AAMA 501,AAMA 505, AAMA 501,AAMA 505, AAMA 501,AAMA 505, AAMA 1503,AAMA 507, AAMA 507,AAMA 1503, AAMA 507,AAMA 1503, AAMA 1503,AAMA1801, AAMA 1801,AAMATIR-A8,AAMA 1801,AAMATIR-A8,AAMA 1801,AAMATIR-A8, Performance AAMATIR-A8, ASTM E283,ASTM E330, ASTM E283,ASTM E330, ASTM E283,ASTM E330, Test Standards ASTM E283,ASTM E330, ASTM E331,ASTM E1425,ASTM E331,ASTM E1425,ASTM E331,ASTM E1425, ASTM E331,ASTM E1425,CSA-A440, CSA-A440, CSA-A440, NFRC 100/200/500 NFRC 100/200/500 NFRC 100/200/500 NFRC 100/200/500 kawneer.com ADMO04EN C KAW N E E R I Architectural Finishes Performing Paints That Let You Design In Vibrant Living • • Black Boysenberry Hartford Green Sandstone Classic Bronze Military Blue Bone White Colonial White Antique Bronze Dove Gray Dark Ivy Charcoal Redwood Sea Wolf Medium Bronze F KAWNEER AN ALCOA COMPANY Superior Performance Coatings That Meet AAMA 2605 Requirements There's a painted finish as expressive and enduring as the Performance Table buildings you design. PermafluorTM Architectural Coatings combine beauty and successful performance as only a 70% fluoropolymer Criteria Performance based coating can. AAMA 2605 Meets or Exceeds Substrate Aluminum only Permafluor'" colors add life to your architectural expressions. Fifteen standard colors and a limitless pallet of custom colors can satisfy your Pretreatment i Multi-Stage Cleaning and Conversion Coating creative needs. The standard colors are always in stock at Kawneer Dry Film Thickness 1.2 mil Paint Facilities for fast turn around while the PermafluorTM custom (ASTM D 7091) colors can be formulated to meet your needs. Specular Gloss Low and Medium This is a paint that endures along with your architectural statement. (ASTM D 523) PermafluorTM is formulated to maintain integrity for years.Outstanding durability translates to substantial maintenance savings over the life of Dry Film Hardness F minimum ASTM D 3363) the building. Impact Resistance 1/10" Deformation Thousands of buildings throughout the world are a testament to the i No Loss of Adhesion lasting beauty and performance of Kawneer standard PermafluorTM Abrasion Resistance Coefficient of 40 minimum Architectural Coatings. ASTM D 968) Salt Spray Hours:2,000 Kawneer#22 Stock Permafluor'"Architectural Coatings ASTM G85 Annex AS) i Scribe or cut edges:Rating 7 The 15 standard PermafluorTM colors shown on this chart are Kawneer i Field:Rating 8 22 stock coatings.They are stocked at Kawneer Paint Facilities for fast Humidity Resistance Hours: 4,000 turn around of painted projects. ASTM D 2247 Few#8 Blisters Max. or ASTM D4585) The following specifications are required for the proper application 10 Years South Florida Color Change:5AE(Hunter)Units Max. and end-use results of PermafluorTM. Performance properties Chalk Resistance:Rating 8 Max. represent minimum results when Permafluor" is applied according to specifications. 10%Muriatic Acid 15 min. Spot Test No Blistering or Visual Change Guide Specifications Mortar(Alkali)Resistance 24 Hour Spot Test,No Visual Change PermafluorT"coating will meet or exceed test requirements of AAMA 72 Hour Detergent No Loss of Adhesion 2605, Voluntary Specification, Performance Requirements and Test Immersion(@ 100°F) Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels. Boiling Water Adhesion No removal of film after 20 min.exposure The following are guidelines for specifying and applying PermafluorTM: Pretreatment — The aluminum shall be thoroughly cleaned using Hylar 5000®is a registered trademark of Solvay Solexis,Inc.,Kyner 5003 is a registered trademark of Arkema Inc. a multi-stage cleaning process to remove organic and inorganic Note:These color samples are as close as possible to actual colors offered within the limitations of surface soils and residual oxides.Apply a chemical conversion coating printing techniques.Final color specification shall be as per approved color samples.PermafluorTM finishes to which organic coatings will firmly adhere. are formulated for Kawneer Company,Inc. Primer — The cleaned and treated substrate shall be primed to a thickness of 0.2—0.3 mils using approved factory application methods. Paint — The PermafluorTM paint system shall contain 70% PVDF Hylar 500011 or Kynar 5000) resin and durable ceramic pigments. It shall be factory applied and oven baked for a topcoat film thickness of 1.0 mil minimum. Clear topcoat, if required, shall be applied at 0.4-0.8 mils. Kawneer Company,Inc. kawneer IIC KAW N E E RTechnologyPark/Atlanta kawneergreegreen.com 555 Guthridge Court 770.449.5555 AN ALCOA COMPANY Norcross,GA 30092 Kawneer Company,Inc.2014 LITHO IN U.S.A. Form No.14-2195 PermafluorT^'is a trademark of Kawneer Company,Inc.and Alcoa Inc.