HomeMy WebLinkAbout20250238 67 Putnam Exterior Modifications NOD
Page 1 of 1
Tamie Ehinger, Chair
Rob DuBoff, Vice Chair
Chris Bennett
Leslie DiCarlo
Jeff Gritsavage
Geoff Wood
Karen Cavotta, Alternate
CITY OF SARATOGA SPRINGS
D ESIGN R EVIEW B OARD
❖
City Hall - 474 Broadway
Saratoga Springs, New York 12866
Tel: 518-587-3550 x.2517
www.saratoga-springs.org
NOTICE OF DECISION
In the matter of the application
#20250238
67 Putnam St. Exterior Modifications
67 Putnam St.
Saratoga Springs, New York 12866
involving Historic review of door replacement and window addition within the Urban Core (UC) District, tax parcel #
165.60-1-62, within the City of Saratoga Springs.
In accordance with 6 NYCRR Part 617, the Design Review Board classifies this request as a SEQR:
Type II action – exempt from further SEQR review
And, in accordance with the objectives, standards and guidelines contained in the Unified Development Ordinance
Article 240-13.9 Architectural Review Applicability and Approval Standards, the Design Review Board issues the
following decision on April 9, 2025:
Approve the plans as submitted or shown on the attached plans
Record of vote:
motion to approve made by T Ehinger, seconded by G Wood: passed 6 -0
As a result of this decision, the applicant:
may proceed with the plans as approved
Please contact the Building Department to verify permit requirements.
Chair Received by Accounts
cc: Building Department File
Accounts Dept.
Applicant/Agent
Exist'g Metal
Framed Opening
Exist'g vent Replace Existing Door With Exi5t'g Brick Infill Exi5t'g Windows (typ)
Fully Glazed Metal Door.
Exist'g Exterior Ductwork
Exist'g Louvers (typ)
25' - 3 1/4"
5EC.OND FLOOR
S
e
FIRST FLOOR
f k x
Exi5t'g
MU Fdn GROUND FLOOR
ExiSt'g Conc. Fdn ExiSt'g Garage Door
PUTNAM 5T 01 - o1,
EX15t'g FDG Exi5t'g wall ENTRY LEVEL
Lights (typ)
Exi5t'g Stone Fdn
New -72" YN x 40" H Alum Window -
Provide Precast Sill and Brick
Soldier Course Above to Match
Existing. Align with Window Above.
Q 00
0
ti
The r ings,plans,specifications and designs contained
herein are and shall remain the exclusive property of
Charette Associates Architects,P.C.,and cannot be
altered,copied,duplicated or used directly or indirectly in
whole or in part except with the express written permission
of Charette Associates Architects,P.C. Copyright 2025
CHAR T S IATES Project: FACADE MODIFICATIONS
No. Description Date
SOUTH ELEVATION Cq
Owner: TOM ROOHAN Project number 2505 N
76 Cobble Hill Drive Address:67 PUTNAM ST Date 3/20/25 S' K_02Gansevoort,New York N
SARATOGA SPRINGS, NY Drawn by LA o
Phone(518)265-2628 Checked by LA Scale 1/16" = 1'-0" N
co
I v
t
e
E
e.
VIEW OF SOUTH WALL DOOR TO BE REPLACED
L.
IMRM.
tires i'IC^....e tS'' ,,..y•rt"'.. ..
ter; e. rl.4Vr'M'plriRfL'L . y L S
e'
Sitt-
i .F
ii!!....
LOCATION OF WORK TO BE PERFORMED
Project Name: Roohan 63 Putnam 3/14/2025 7:03 AM
Frame Set Name: Frame Set 1 Frame Name: Exterior Entrance
Metal Group: M450 CG/SS/OG STOPS UP D/S: 1 Frame Type: Standard
Required: 1 Panels: 1 Rows: 1 Frame Width: 47 1/2 Frame Height: 81 3/4
Back Member Color: #22 MILITARY BLUE : FLUROPON Face Member Color: #22 MILITARY BLUE : FLUROPON
LL
O
c+n
W
t
Report Provided Courtesy of PartnerPak Studio-5.0.0.122 Page: 1 Of 3
Project Name: Roohan 63 Putnam 3/14/2025 7:03 AM
Frame Set Name: Frame Set 1 Frame Name: Interior Door
Metal Group: M450 CG/SS/OG STOPS UP D/S: 1 Frame Type: Standard
Required: 1 Panels: 1 Rows: 1 Frame Width: 39 1/2 Frame Height: 81 3/4
Back Member Color: #22 MILITARY BLUE : FLUROPON Face Member Color: #22 MILITARY BLUE : FLUROPON
39 1/2 (u.A.FR)
36
E
LL
0
t
LL I LJ I
Report Provided Courtesy of PartnerPak Studio-5.0.0.122 Page: 2 Of 3
Project Name: Roohan 63 Putnam 3/14/2025 7:03 AM
Frame Set Name: Fixed frame Frame Name: Fixed
Metal Group: M451T CG/SS/OG STOPS UP D/S: 1 Frame Type: Standard
Required: 1 Panels: 2 Rows: 2 Frame Width: 72 Frame Height: 42
Back Member Color: #22 MILITARY BLUE : FLUROPON Face Member Color: #22 MILITARY BLUE : FLUROPON
72[unFn;
m
Ln
trJ 1 LL
n W Q
r N p
H a
U
T T
m
m
Report Provided Courtesy of PartnerPak Studio-5.0.0.122 Page: 3 Of 3
190, 350 AND 500 STANDARD ENTRANCES KAWNEER
Single-Source Packages
Generate Versatile
First Impressions
Dallas,
lp
AN IMMMMM
Curtis Culwell Center
Garland,Texas
ARCHITECT
as
GLAZING CONTRACTOR
PHOTOGRAPHERB&B Glass,Inc.,Dallas,Texas
Tough yet attractive, Kawneer's Standard Entrances are designed as a PERFORMANCE
single-source package of door,door frame and hardware that is easily To resist both lever arm and torsion forces that constantly act on any
adaptable to custom requirements. Designed to complement new or door,all three entrances feature welded corner construction with Sigma
remodel construction as well as modern or traditional architecture,they deep penetration and fillet welds plus mechanical fastenings at each
are engineered,constructed and tested to make a good first impression corner—a total of 16 welds per door. Each door corner comes with a
while withstanding the rigors of constant use by occupants and visitors. limited lifetime warranty,good for the life of the door under normal use.
It is transferable from building owner to owner and is in addition to the
standard two-year warranty covering material and workmanship of each
Kawneer door.
1.Thermoplastic GENERAL
elastomer weatherstrip
in blade stop of frame • Heights vary up to 10';widths range from approximately 3'to 4'
jambs,header or
transom bar.
Door frame face widths range to a maximum of 4",while depths
range to b"
2•Integral polymeric fin .
Door operation is single-or double-acting with maximum securityattachedtoadjustable
astragal,creating an air locks or touch bar panics standard
barrier between pairs • Architect's classic 1" round, bent bar push/pull hardware is availableofdoors.
in various finishes and sizes
T
3.Optional surface-
Infill e from 1/4" to 1"applied bottom s rang
weatherstrip with
flexible blade gasket.
Extruded raised lip on
threshold to provide FOR THE FINISHING TOUCH
continuous contact for
bottom weatherstrip. Architectural Class I anodized aluminum finishes are available in clear
4.Standard 1/4"beveled and Permanodic®color choices.
glass stops to sheet
water and dirt off
without leaving residue. Painted finishes, including fluoropolymer,that meet AAMA 2605 are
5.Available in all finishes offered in many standard choices and an unlimited number of specially
offered by Kawneer.
designed colors.
Solvent-free powder coatings add the"green"element with high
performance,durability and scratch resistance that meet the standards
ECONOMY of AAMA 2604.
Kawneer's bulb neoprene weatherstripping forms a positive seal
around the door frame and provides a substantial reduction in air
infiltration,resulting in improved comfort and economies in heating
and cooling costs.The system is wear-and temperature-resistant and Sigma fillet welds top
replaces conventional weatherproofing.The bottom weatherstrip
and bottom
Sigma deep
Steel back-up plate
penetration plug welds
at the interior contains a flexible blade gasket to meet and contact top and bottom
the threshold,enhancing the air and water infiltration performance
characteristics.
190 NARROW STILE ENTRANCE
Is engineered for moderate traffic in applications such as stores,
Reinforcing:chann)el *
offices and apartment buildings
Vertical stile measures 2-1/8",top rail 2-1/4" and bottom rail 3-7/8"
Results in a slim look that meets virtually all construction requirements
350 MEDIUM STILE ENTRANCE
Provides extra strength for applications such as schools, institutions
and other high-traffic applications
Vertical stiles and top rails measure 3-1/2"
Bottom rail measures 6-1/2" for extra durability
500 WIDE STILE ENTRANCE
Creates a monumental visual statement for applications such as
banks, libraries and public buildings
Vertical stiles and top rail measures 5"; bottom rail measures 6-1/2"
Results in superior strength for buildings experiencing heavy traffic
conditions
Kawneer Company,Inc.
Nor GuthToss, A 3
Court
kawn er.co
C KAW N E E RKawneerCompany,Inc.2012-2019 Technology Park lAtlanta Norcross,GA 30092 kawneer.com
Form Number 17-2225.E
Permanodic®is a registered
r a
nmdemarkorKaw"ee,comPe"Y,i"e.
ARCHITECTURAL SYSTEMS I ENTRANCES+FRAMING I CURTAIN WALLS I WINDOWS
NOVEMBER, 2024 Product Selection Guide
EC 97911-330 SWING DOORS - STANDARD ENTRANCES
190 350 500
Product Standard Entrances Standard Entrances Standard Entrances
Narrow Stile Medium Stile Wide Stile
Catalog Section Entrances Entrances Entrances
xda
3 ° Typical
3 ` Detail
N a,O
O V Q ry
N
j O C s
c3o'y
rncw c
r 3 Sightline 2-1/8" 3-1/2" 5"
O j O
rnca c
C O N
a;Depth 1-3/4" 1-3/4" 1-3/4"
O C_ C N
M 3 O N
d °O Moderate Moderate to High High
Aonsa!t
Applications
Traffic Traffic Traffic
No Nii E
m g m Infill Options Up to 1"Up to 1"Up to 1"
U N O]
Cross Rails/Muntins Yes Yes Yesa
m
303E
aY t Thermal No No No
2 Color Option No No No
190 narrow stile entrance door 350 medium stile entrance door 500 wide stile entrance door
offers a slim appearance,features offers a rugged appearance features dual-moment corner
dual-moment corner construction features dual-moment corner construction, and it creates a
and is designed for applications construction and is designed for monumental visual appearance
such as offices, stores and schools,institutions,and other high for banks, libraries or buildings
e apartment buildings. traffic conditions. experiencing the heaviest trafficd
conditions.
Product
3 Description
U
OC
O
O.
O
L
3
c0
rn
Testing for
m
Protective Glazing
g Performance
o Class/Ratinga
t o
ASTM E283 ASTM E283 ASTM E283
N Q Dual Moment Corner Dual Moment Corner Dual Moment Corner
N O. NC
y w 3
Z` Y
m 7
3 coi °N
Y o Performance
Test Standards
kawneer.com ADMO04EN C KAW N E E R
DESIGN AND PERFORMANCE
VERSATILITY WITH UNMATCHED
FABRICATION FLEXIBILITY
1Yr ti<
TRIFAB°VERSAGLAZE° 450, 451 & 451T (THERMAL) FRAMING
SYSTEMS &TRIFAB° 451 UT (ULTRA THERMAL) FRAMING SYSTEM
Trifab°VersaGlaze° is built on the proven and successful Trifab°platform—with all
the versatility its name implies.There are enough framing system choices, fabrication
methods, design options and performance levels to please the most discerning building
owner,architect and installer. The 4.5" depth Trifab°VersaGlaze° Framing System family
is available with non-thermal, thermal and ultra-thermal performance levels.
The ultra-thermal Trifab°451 UT Framing System, is designed for the most demanding
thermal performance and employs adual Isolock°thermal break.
BKCKAWNEER gadig I
AESTHETICS Photography: Ben Gancsos
Trifab°VersaGlaze°Framing Systems offer designers
a choice of front-,center-, back-or multi-plane glass
applications. Structural silicone glazing(SSG)and
weatherseal glazing options further expand designers'
choice, allowing for a greater range of possibilities for
specific project requirements and architectural styles.
All systems have a 4-1/2" frame depth;Trifab®VersaGlaze°
450 has 1-3/4" sightlines,while Trifab°VersaGlaze°451/451T
and Trifab°451 UT have 2" sightlines.
With seamless incorporation of Kawneer entrances
or windows, including GLASSvent°visually frameless
ventilators,Trifab°framing can be used on almost any
project.These framing systems can also be packaged
with Kawneer curtain walls and overhead glazing,thereby
providing a full range of proven, and tested, quality
products for the owner,architect and installer from
to o
a single-source supplier.
ECONOMY
Trifab°VersaGlaze°450/451/451 T/451 U T Framing Systems
offer a variety of fabrication choices to suit your project:
Screw Spline—for economical continuous runs utilizing
two-piece vertical members that provide the option to
pre-assemble units for efficient handling and installation.
available for all Trifab systems) All systems can be flush glazed from either the inside
or outside. The weatherseal option provides an
Shear Block—for punched openings or continuous alternative to SSG vertical mullions for Trifab°
runs using tubular verticals with shear blocks to connect VersaGlaze®450/451/451T. This ABS/ASA rigid polymer
horizontal members.(available for 450/451/451T systems) extrusion allows complete inside glazing and creates
a flush glass appearance on the building exterior
Stick—for fast,easy field fabrication.Continuous sill and without the added labor of scaffolding or swing stages.
head receptors are installed with horizontals connected Additionally, high-performance flashing options are
to tubular verticals with shear blocks.(available for engineered to eliminate perimeter sill fasteners and
450/451/451Tsystems) associated blind seals.
Pre-glazed—The combination of screw spline
construction with pre-glazing in the shop accelerates
FOR THE FINISHING TOUCHinstallationandreducesfieldlabortimewhileminimizing
disruption to the surrounding area or existing tenants. Architectural Class I anodized aluminum and painted
Making it an exceptional choice for new or retrofit finishes influoropolymer(AAMA 2605) and solvent-
applications, particularly in urban areas or where space free powder coatings (AAMA 2604) offer a variety
is limited.(available for 451/451T/451 UT framing) of color choices.
IFICKAWNEER
PERFORMANCE
Kawneer's Isolock°thermal break technology creates U-factor, CRF values and STC ratings for Trifab°framing
a composite section, prevents dry shrinkage and is systems vary depending upon the glass plane application.
available on Trifab°VersaGlaze°451T. For even greater Project-specific U-factors can be determined for each
thermal performance, a dual Isolock°thermal break is individual project.
used on Trifab°451 UT.
See the Kawneer Architectural Manual or Kawneer.com for additional information.)
W
Trifab°451 UT uses a dual Isolock°thermal break(right)
and features a new high performance sill design,which
incorporates a screw-applied end dam (left), ensuring
positive engagement and tight joints between the sillALflashingandenddam.
PERFORMANCE TEST STANDARDS
Thermal simulations showing temperature variations from
exterior/cold side to interior/warm side.
Air Infiltration ASTM E283
Water AAMA 501,ASTM E331
Structural ASTM E330
Thermal AAMA 1503
Trifab® Trifab®VersaGlaze® Trifab®451UTThermalBreakAAMA505,AAMA TIR-A8
VersaG laze"451 451T
Acoustical AAMA 1801,ASTM E1425
aP ne ir-r ar M ur NP as Vr
DOLE WARM
Front Center Back SSG Weatherseal Multi-Plane
Kawneer Company,Inc.2024
Form Number 17-2241.B
IC KAW N E E R Technology Park/Atlanta
555 Guthridge Court
Norcross,GA 30092
NOVEMBER, 2024 Product Selection Guide 11
EC 97911-330 STOREFRONT FRAMING -THERMAL
Trifab®VersaGlaze® Trifab®451UT Trifab®VersaGlaze° Trifab®VersaGlaze®
Product 451T Framing System Framing System 601T Framing System 601UT Framing System
2"x 4-1/2") 2"x 4-1/2") 2"x 6") 2"x 6")
Catalog Section Framing Framing Framing Framing
x
Typical
3 Detail
N a,O
O U 0 N
J 2 L
o T Storefront Storefront Storefront Storefront
Applications Ribbon Windows Ribbon Windows Ribbon Windows Ribbon Windows
a
Punched Openings Punched Openings Punched Openings Punched Openings
m Center,Front, Center Center=0 °Glass Plane Options
Back,Multi-Plane
Center
Front FrontCc3aEa; O` E
O C C N
3° Infill Options Up tot-1/8" Up tot-1/8" Up tot-1/8" Up tot-1/8"
U {Cp N N
t Inside Glazed Inside Glazed Inside Glazed Inside Glazedwccy ; Glazing Options
Outside Glazed Outside Glazed Outside Glazed Outside GlazedoE
m Isol-ock® Dual Isol-ock® Dual Isol-ock® Dual Isol-ock®
M Thermal
m Pour and Debridge Pour and Debridge Pour and Debridge Pour and Debridge
a w 0 °
y ; 3 SSG Optional No Yes(Front) Yes(Front)
3 2 30JnY L
Weatherseal Optional No No No
2 Color Option
Yes
with Front Stick
No No No
Integrated Entrance
Yes Yes Yes Yes
Framing
WindoE
Integra
YesYes Yes Yes Yes
d
3 GLASSvent®
Yes Yes Yes Yes
Integration
0
o Versoleil®Sunshade
Yes Yes Yes(Center Only)Yes(Center Only)Integration
0
Z
3 Fabrication Screw Spline,Shear Block, Screw Spline,Shear Block,Screw Spline,Shear Block,
Method Stick,Continuous Head and Sill
Screw Spline
Stick Stick
AT x 4-1/2"flush glazed system for AT x 4-1/2"flush glazed system for A 2"x 6"flush glazed system for A 2"x 6"flush glazed system for
1"glass.VersaGlaze®is engineered 1"glass.Engineered to perform to 1"glass.Engineered to perform to 1"glass.Engineered to perform to
for design and fabrication versatility current energy code requirements current energy code requirements current energy code requirements
with variable glass planes choices, using a dual Isol-ock®thermal using a dual Isol-ock®thermal using a dual Isol-ock®thermal
g Product
SSG or Weatherseal options, break. break. break.
e Description
Isol-ock®thermal break option and
t E four types of fabrication.
0
N 2N
C
z Y Testing for
Protective Glazing
Y ` o AAMA 501.1,AAMA 507, AAMA 501,AAMA 505, AAMA 501,AAMA 505, AAMA 501,AAMA 505,
AAMA 501,AAMA 505, AAMA 1503,AAMA 507, AAMA 507,AAMA 1503, AAMA 507,AAMA 1503,
AAMA 1503,AAMA1801, AAMA 1801,AAMATIR-A8,AAMA 1801,AAMATIR-A8,AAMA 1801,AAMATIR-A8,
Performance AAMATIR-A8, ASTM E283,ASTM E330, ASTM E283,ASTM E330, ASTM E283,ASTM E330,
Test Standards ASTM E283,ASTM E330, ASTM E331,ASTM E1425,ASTM E331,ASTM E1425,ASTM E331,ASTM E1425,
ASTM E331,ASTM E1425,CSA-A440, CSA-A440, CSA-A440,
NFRC 100/200/500 NFRC 100/200/500 NFRC 100/200/500 NFRC 100/200/500
kawneer.com ADMO04EN C KAW N E E R
I Architectural Finishes
Performing Paints
That Let You Design In
Vibrant Living • •
Black Boysenberry Hartford Green
Sandstone Classic Bronze Military Blue
Bone White Colonial White Antique Bronze
Dove Gray Dark Ivy Charcoal
Redwood Sea Wolf Medium Bronze
F KAWNEER
AN ALCOA COMPANY
Superior Performance Coatings
That Meet AAMA 2605 Requirements
There's a painted finish as expressive and enduring as the Performance Table
buildings you design. PermafluorTM Architectural Coatings combine
beauty and successful performance as only a 70% fluoropolymer Criteria Performance
based coating can. AAMA 2605 Meets or Exceeds
Substrate Aluminum only
Permafluor'" colors add life to your architectural expressions. Fifteen
standard colors and a limitless pallet of custom colors can satisfy your Pretreatment i Multi-Stage Cleaning and Conversion Coating
creative needs. The standard colors are always in stock at Kawneer
Dry Film Thickness 1.2 mil
Paint Facilities for fast turn around while the PermafluorTM custom (ASTM D 7091)
colors can be formulated to meet your needs.
Specular Gloss Low and Medium
This is a paint that endures along with your architectural statement. (ASTM D 523)
PermafluorTM is formulated to maintain integrity for years.Outstanding
durability translates to substantial maintenance savings over the life of Dry Film Hardness F minimum
ASTM D 3363)
the building.
Impact Resistance 1/10" Deformation
Thousands of buildings throughout the world are a testament to the i No Loss of Adhesion
lasting beauty and performance of Kawneer standard PermafluorTM Abrasion Resistance Coefficient of 40 minimum
Architectural Coatings. ASTM D 968)
Salt Spray Hours:2,000
Kawneer#22 Stock Permafluor'"Architectural Coatings ASTM G85 Annex AS) i Scribe or cut edges:Rating 7
The 15 standard PermafluorTM colors shown on this chart are Kawneer i Field:Rating 8
22 stock coatings.They are stocked at Kawneer Paint Facilities for fast
Humidity Resistance Hours: 4,000
turn around of painted projects. ASTM D 2247 Few#8 Blisters Max.
or ASTM D4585)
The following specifications are required for the proper application
10 Years South Florida Color Change:5AE(Hunter)Units Max.
and end-use results of PermafluorTM. Performance properties Chalk Resistance:Rating 8 Max.
represent minimum results when Permafluor" is applied according
to specifications.
10%Muriatic Acid 15 min.
Spot Test No Blistering or Visual Change
Guide Specifications Mortar(Alkali)Resistance 24 Hour Spot Test,No Visual Change
PermafluorT"coating will meet or exceed test requirements of AAMA
72 Hour Detergent No Loss of Adhesion
2605, Voluntary Specification, Performance Requirements and Test Immersion(@ 100°F)
Procedures for Superior Performing Organic Coatings on Aluminum
Extrusions and Panels. Boiling Water Adhesion No removal of film after 20 min.exposure
The following are guidelines for specifying and applying PermafluorTM:
Pretreatment — The aluminum shall be thoroughly cleaned using Hylar 5000®is a registered trademark of Solvay Solexis,Inc.,Kyner 5003 is a registered trademark
of Arkema Inc.
a multi-stage cleaning process to remove organic and inorganic
Note:These color samples are as close as possible to actual colors offered within the limitations of
surface soils and residual oxides.Apply a chemical conversion coating printing techniques.Final color specification shall be as per approved color samples.PermafluorTM finishes
to which organic coatings will firmly adhere.
are formulated for Kawneer Company,Inc.
Primer — The cleaned and treated substrate shall be primed to a
thickness of 0.2—0.3 mils using approved factory application methods.
Paint — The PermafluorTM paint system shall contain 70% PVDF
Hylar 500011 or Kynar 5000) resin and durable ceramic pigments.
It shall be factory applied and oven baked for a topcoat film thickness
of 1.0 mil minimum. Clear topcoat, if required, shall be applied at
0.4-0.8 mils.
Kawneer Company,Inc. kawneer IIC KAW N E E RTechnologyPark/Atlanta kawneergreegreen.com
555 Guthridge Court 770.449.5555
AN ALCOA COMPANY
Norcross,GA 30092
Kawneer Company,Inc.2014 LITHO IN U.S.A. Form No.14-2195
PermafluorT^'is a trademark of Kawneer Company,Inc.and Alcoa Inc.