HomeMy WebLinkAbout20241018 NYS Route 29 Prime Station Lane UDO Project Review1
CITY OF SARATOGA SPRINGS – UNIFIED DEVELOPMENT ORDINANCE
PROJECT REVIEW
Project Information
Project Name / App#: Station Park Subdivision and Site Plan
Parcel No.: 165-2-70; 165-2-18, 165-2-19
Zoning District: NC Neighborhood Center District (Transect Zone 5)
The NC Neighborhood Center District is intended to accommodate a wide variety of residential and nonresidential
uses in a moderate intensity mixed-use environment. This district also focuses on providing quality streetscape
amenities and civic spaces to enhance pedestrian activity.
Proposed Use: Multifamily, Townhouses, and Hotel
Date of Review: March 31, 2025
UNIFIED DEVELOPMENT ORDINANCE COMPLIANCE REVIEW
Key Requirement
Info Provided Compliant
Comment Yes No Yes No
Commercial Mixed-Use Districts Dimensional Standards (4.4)
*Includes NC (T-5) District *Applies to Multifamily Buildings and Hotel
Build-to Zone
Table 4-C Front
ROW >40’
0’ to 12’ BTZ X X Public ROW abutting Hotel include
proposed Station Park Avenue and NYS
Route 29. Hotel is >12’ to lot line abutting
NYS Route 29.
Table 4-C Build-out
abutting public
ROW
70% (does not apply
to SF, SF-A, 2F, TH)
X X Applies to Lots #1, #6, #8, and #9
Lot #1 (<70% build-out on Station Park Ave
and Station Lane)
Lot #6 (Station Park Ave - approx. 252’
façade length, lot line length 371.43’,
67.8%) (NYS Rt 29 – entirety of building
line outside BTZ)
2
Key Required Info Provided Compliant Comments
Yes No Yes No
Table 4-C Interior side 0’ min. X X
Table 4-C Rear 0’ min. X X
Public Civic Space
4-D/9.3 Public civic space
required for
developments of
20,000 sf
5% min lot area Per Sheet C-3, the
applicant has stated
their intent to
enhance park or
nature trails North of
the site. Additional
details are needed.
Discretion of
Planning Board.
Per 9.3.D.8., civic space may be located off
the subject site but within the same block
and combined with other existing public
civic space located on that block. The
Planning Board must find that combining
the required public civic space with
existing space creates a more usable area
of the public. No reduction in the amount
of area required is allowed.
Bulk
Table 4-C Minimum
building height
24’ min X X
Table 4-C Maximum
building height
1.1x width of ROW or
50’ (whichever is
less)
X
X ROW width (Station Park Ave) of 76’ x 1.1
= 83.6’
50’ < 83.6’
Multi-Family Building #1: 48’ building
height, 53.63’ exposed average height
noncompliant
Multi-Family Building #2: 48’ building
height, 53.16’ exposed average height
noncompliant
Hotel: 42’ building height, 49.06’ exposed
average height compliant
(Per Civil Site Plan, Sheet C-4)
Per 21.4.D, maximum building height is
measure from grade. Per Article 21.4.G,
grade is the average of the finished
ground level of each wall of a building
measured vertically along the façade and
averaged.
Table 4-C Optional corner
lot element
25% max X Unknown if applicant plans to include
corner lot elements in design. Needs to be
confirmed by applicant or through review
of building renderings.
Table 4-D Development
bonus
Discretion of
Design Review
Board
Applicant noted the potential to use a
development bonus to address building
height (Sheet C-4).
Residential Mixed-Use Districts Dimensional Standards (4.3) – includes UN District
* Permitted single-family, single-family attached, two-family, and townhouse dwellings are not subject to these standards [Commercial Mixed-Use
Districts Dimensional Standards] but rather subject to the standards of the UN District for such dwelling types.
Bulk
Table 4-A Min lot area, min
lot width, max
building coverage
None X
Table 4-A Maximum
Impervious
Surface
75% Applicant has indicated that 35% of the
project area is impervious.
This is an overall calculation and is not
broken down per lot. Several individual
lots appear to exceed the maximum.
Table 4-A Maximum
Building Height
40’ X Townhouse height not included on Sheet
C-4.
Setbacks
Table 4-A Min. Front
setback
Build-to zone of 12’
to 18’
X X
3
Table 4-A Min. Build-Out 50% X X
Key Required Info Provided Compliant Comments
Yes No Yes No
Table 4-A Min. interior side
setback
5’ X X
We suggest the applicant verify side
setbacks. The side setbacks associated
with the following townhouses appear to
be noncompliant: 7, 12, 13, 18, 19, 25, 30,
34, 35, 40, 41, and 46.
Table 4-A Min. rear setback 24’ X X
We suggest the applicant verify rear
setbacks. The following lots appear to be
noncompliant: 2, 3, 4, 5, 11, 12, and 13
Design Standards
Single-family, single-family attached, two-family, and townhouse dwellings are not subject to these standards [Commercial Mixed-Use Districts
Design Standards] but rather subject to the design standards by dwelling type of Article 8 (4.4.C.1.c).
a.i. Windows, entrances, porches, or other
architectural features are required on all
street-facing facades to avoid the
appearance of blank walls.
X Renderings needed to confirm.
a.ii. Facades must be designed with consistent
materials and treatments that wrap
around all facades. There must be a
unifying architectural theme for the entire
development, utilizing a common
vocabulary of architectural forms,
elements, materials, or colors in the entire
structure.
X Renderings needed to confirm.
a.iii. Building facades abutting a street or
abutting the City Trail System must be
articulated through the use of
architectural elements to break up blank
walls and add visual interest.
X Renderings needed to confirm.
a.iv. A minimum transparency of 10% applies to
any facade facing a street or abutting the
City Trail System, and is calculated on the
basis of the entire area of the facade.
X Renderings needed to confirm.
a.v. A minimum separation of 15 feet between
townhouse dwellings within a larger
development that contains multiple
townhouse dwellings. However, where the
front or rear wall of the townhouse
development faces the front or rear wall of
another townhouse development, the
minimum required separation between
such developments must be 30 feet.
Driveways and parking areas may be
located within this minimum separation
area.
X X <15’ between Townhouses 12 – 13, 18 –
19, 34 – 35, and 40 – 41.
a.vi. Development is subject to the public civic
space requirements of Section 9.3.
Addressed above.
a.vii. Where private open space for residents is
maintained along the City Trail System, any
fencing that delineates the private open
space from public space must be open
fencing of at least 60% open design and no
more than six feet in height. Privacy
fencing is prohibited.
N/A. Fencing does not appear to be
proposed along the multi-use path.
b. Prohibited Building Materials X Need further information.
4
Key Required Info Provided Compliant Comment
Yes No Yes No
Commercial Mixed-Use Districts Design Standards (Table 4-E)
*Applies to Multi-Family Buildings and Hotel
Building Orientation
1 All buildings must be oriented toward a
primary street
X X
Defer grading review to City Engineer. 2 All public entrances must include direct
pedestrian connections between street
facing doors to adjacent sidewalks.
X X
3 Ground floor entrances into individual
residential units must be between 2’ and
7’ above sidewalk grade.
4 Garage doors must not be located on the
front of buildings, but rather must face the
side or rear of the property.
X X
Building Form and Façade Design
5 Building facades that abut a public right-
of-way (excluding alleys) must not contain
blank wall areas that exceed 30 linear feet,
measured per story parallel to the street.
X
Renderings needed to confirm.
6 Facades must be divided into multiple
“modules,” expressed through significant
architectural changes such as a change in
materials, a change in pattern elements
such as fenestration, columns or pilasters,
or a change in building setback through
recesses or projections. For buildings 150’
in length or greater, such modules may be
no wider than 50 feet.
X
Renderings needed to confirm.
7 Facades must express a traditional visual
distinction between the ground floor and
upper stories through architectural
features or detailing, change in materials,
or a change in pattern elements such as
fenestration. Where existing adjacent
buildings contain such horizontal features
or datum lines distinguishing the ground
floor from upper stories, new building
facades must match the heights of such
features to create visual continuity along
the face of a block.
X
Renderings needed to confirm.
8 Design elements for public entrances X Renderings needed to confirm.
9 Commercial storefronts must include
traditional pedestrian-oriented elements
such as display windows, knee walls,
transoms and cornices.
N/A
10 The ground floor of a building facade
abutting a public right-of-way (excluding
alleys) must maintain a minimum
transparency of 50%, measured between
two feet and ten feet in height.
X
Renderings needed to confirm.
11 The upper floors of a building facade
abutting a public right-of-way (excluding
alleys) must maintain a minimum
transparency of 15% of the wall area of the
story.
X
Renderings needed to confirm.
12 The ground floor of a building facade
abutting a rear parking area that contains
a public entrance must maintain a
minimum transparency of 20%, measured
between two and ten feet in height.
X
Renderings needed to confirm.
5
Key Required Info Provided Compliant
Comments Yes No Yes No
13 All architectural openings, including
windows, doorways, arches, porch
framing, etc. must maintain a height equal
to or greater than their width to
emphasize the verticality of such
elements.
X
Renderings needed to confirm.
14 Window shutters, whether functional or
used as a decorative element, must be
used consistently across the building
facade, and must be proportioned so as to
cover the window opening when closed.
X
Renderings needed to confirm.
15 Buildings must be designed with consistent
building materials and treatments that
wrap around all facades visible from a
public street. Where material or color
treatments change, there should be a
significant change in surface plane of a
minimum of six inches in difference.
Differing materials are encouraged to
terminate at inside corners.
X
Renderings needed to confirm.
16 Mechanical equipment and structural
components such as vents must be located
and screened to minimize visibility.
X
Renderings needed to confirm.
Roof Design
17 Roof forms may include symmetrical
pitched roofs or flat roofs with cornice
treatments. Slopes of pitched roofs may
not be less than 5:12, except that porch
roofs may be sheds with pitches not less
than 3:12.
X
Renderings needed to verify.
18 Rooflines of 100’ in length or more must
be varied through the use of architectural
design elements such as dormers, gables,
or projected wall features. Such elements
of variation may be no wider than 50’.
X
Renderings needed to verify.
19 Reflective roof surfaces that produce glare
are prohibited, except for cool roofs
intended to radiate absorbed or non-
reflected solar energy and reduce heat
transfer to the building.
X
Renderings needed to verify.
20 Where parapet walls are used, they must
feature three-dimensional cornice
treatments or other shadow-creating
details along their tops.
X
Renderings needed to verify.
Site Design
21 Sites must be designed to ensure safe
pedestrian and bicycle access from the
public ROW and within the development.
Interconnected sidewalks and midblock
crossings included on site plan.
Unsure where bike storage pods are
located. Abundance of on-street parking
may cause conflict with bicyclists (open
car doors in path of cyclists, little buffer
between bicyclists and motorists).
22 A cohesive visual character must be
maintained through the use of
coordinated hardscape and landscape
treatments.
23 Off-street parking and traffic flow must not
interfere with the flow of pedestrian travel
or detract from aesthetic character.
X X
24 Vehicular access to parking and service
areas must be provided from an alley
wherever possible.
X X
Uses (4.2)
4.2 /
Article 8
Multi-Family –
Residential
Structure Only
Special Use X Multifamily use requires a special use
permit
Townhouse Permitted Use
Hotel Permitted Use
6
Key Requirement Info Provided Compliant Comments
Yes No Yes No
Off-Street Parking and Loading (10)
10.2 Parking location Residential Uses –
driveway/off-street
spaces cannot project
over the sidewalk or
ROW
Non-residential Uses
– Behind front
building line
X X
2 spaces appear to be in front of the
hotel’s front building line.
Table 10-B Number of
accessible spaces
2% of total X X 750 * 2% = 15 ADA spaces required
Provided: 18
4 in surface lots, 4 at hotel, 2 on private
drive, 8 in subgrade parking garage
Per 10.3.B, each accessible parking space
must be marked with ADA-compliant
signage and any other applicable
standards of the ADA.
10.3.C.2 Access All parking facilities
must have an internal
pedestrian circulation
system that allows
passage between
parking areas and use
served.
X X Site includes interconnected sidewalks
and mid-block crosswalks along the
proposed Station Park Avenue.
The Planning Board may want to require
the addition of a walkway between the
southern end of the playground lot to the
adjacent sidewalk and crossing.
10.3.C.5 Turnaround Turnaround space
min. depth and width
of 9’, must be
designated with signs
stating “No Parking”
and painted to
indicate parking.
X X Dead-end parking lots on site: Surface lot
behind townhouses #1 – 6, hotel surface
lot, surface lot adjacent to playground,
subgrade parking facility.
Turnaround with min. depth and width of
9’ included for all dead-end parking lots.
Applicant must include appropriate
striping and signage in these areas.
10.3.G /
Section 9.4
Lighting Townhouse
developments the
maximum allowable
footcandle at any lot
line is one
footcandle;
correlated color
temperature (CCT) at
or below 3,000°K;
Full cut-off; Max
height 20’
Applicant to confirm max footcandle
measurement at lot line behind
Townhouses #1 – 6 and #25 – 30. May
want to consider including a back shield
on fixture (LP-C-SL3-HS).
LP-A, LP-B, LP-D have acorn lens –
applicant to confirm if fixture is dark sky
compliant/full cut-off.
Applicant to confirm if any building
mounted/wallpack lighting proposed.
2200 color temperature (LP-A, LP-B)
Applicant to confirm color temperature of
LP-C.
10.3.H /
Article 11
Landscaping Lots with >4 spaces,
drainage must be
connected to a public
stormwater if located
within 500’ of an
available public
storm sewer system.
Defer to City Engineer to confirm.
10.5.F. EV charging
stations (>30
parking spaces)
5% EV-ready or
2% EV-installed
X X 750 required spaces * 5% = 37.5 spaces
750 * 2% = 15 spaces
EV spaces provided: 30
22 in surface lots, 8 in subgrade garage
per underground parking plan
7
Key Requirement Info Provided Compliant Comments
Yes No Yes No
Table 10-C Parking spaces
per use(s)
Dwelling – Multi-
Family/Townhouse
(1.5 per du in NC)
Hotel – 1.5 per room
# of vehicle parking
spaces cannot exceed
120% of required
minimum unless
waived by the
Planning Board
X X 46 Townhouses + 184 units Bldg #1 + 160
units Bldg #2 = 390 dwelling units
390 du * 1.5 =585
110 hotel rooms * 1.5 = 165
Total required: 750
Applicant includes maintenance building in
calculation. It has been excluded here
assuming the building is an accessory use.
Spaces Provided: 751 (mix of on-street,
surface lot, garage, and subgrade spaces)
Corrections Needed
-Mislabeled number of parking spaces in
northern Building #1 surface parking lot
(labeled 10, 9 → actual 11, 10)
-Mislabeled street parking west of Building
#2 (labeled 17 → actual 15)
*Please indicate which Townhouse Units
include 2-car garages on Sheet C-2
Table 10-C Bicycle spaces
per use(s)
Dwelling – Multi-
Family/Townhouse (1
per 4 du)
Hotel – N/A
After the first 25
required bicycle
parking spaces are
provided, any
additional bicycle
parking spaces are
required at a 50%
reduction.
X X 46 Townhouses + 184 units Bldg #1 + 160
units Bldg #2 = 390 dwelling units
390 du / 4 = 97.5 bicycle spaces
First 25 bike spaces + (remaining 72.5 *
50% = 36.25 spaces) = 61.25, round up to
62 required bicycle spaces
Provided: (2 pods of 8 bikes = 16) + (4 pod
pf 20 = 80) = 96 bicycle spaces
This cannot be verify but is mentioned by
the applicant on Sheet C-2.
Table 10-C Long-term bicycle
spaces per use(s)
Dwelling – Multi-
Family/ Townhouse
(80%)
Hotel – N/A
X Applicant needs to verify. Do pods
mentioned in notes allow for long parking
periods and provide safe and
weatherproof storage?
10.6 On-street parking For nonresidential
uses – new on-street
spaces may count
toward required off-
street parking but
must be located
along the corner, side
or front lot line.
X X New on-street parking spaces are
provided along the proposed Station Park
Avenue which is adjacent to the front/side
lot lines of the proposed townhouses,
multi-family building, and hotel
10.7 Bicycle Parking
Standards
Design, Location
Bicycle parking racks
must permit the
bicycle frame and
one wheel to be
locked to the rack
and support the
bicycle in a stable
position. Structures
that require a user-
supplied locking
device must be
designed to
accommodate U-
shaped locking
devices.
X Unsure location of bike racks.
Proposed bike rack does not appear
effectively accommodate U-locks as the
design supports the front wheel only with
the frame unsecured. Image from Belsen
Outdoors.
Link
10.8 # Off-street
Loading Spaces
1 space min for >50
dwelling units
1 space min for
10,000 – 100,000 sf
GFA commercial use
X X Loading spaces provided: in front of hotel,
2 spaces along west side of multifamily
buildings, within northern multifamily lot
adjacent to Building #1, within southern
multifamily lot adjacent to Building #2
8
Key Requirement Info Provided Compliant Comments
Yes No Yes No
Landscape (11)
The Planning Board, during review of the landscape plan, may allow exceptions to on-site landscape standards if such exceptions meet some or all of
the standards outlined in 11.3 of the code.
Table 11-A Plant diversity
requirements
50+ plants – max # of
one species (15%),
min # of species (15)
X X Number of species and % of each appear
to follow plant diversity requirement
11.4 Site landscape
*Does not apply
to townhouse
dwellings; does
not apply where
parking lot is
located in front
of the structure
and abuts a
street.
Setback areas include
min 1 broadleaf tree
or 2 ornamental trees
and 5 shrubs for
every 30 linear feet
of setback area when
structure is setback
10’ or more from a
front or corner side
lot line.
X X
Approx. 287’ front lot line along Station
Park Ave for hotel
Approx. 845’ front lot line along Station
Park Ave for Multi-Family Buildings
Hotel:
287/30 = 9.5 (9.5 trees + 47.5 shrubs)
Provided in setback area – 7 trees, >48
shrubs
Multifamily:
845/30= 28 (28 trees + 140 shrubs)
Provided in setback area – no trees (trees
provided in the ROW and elsewhere on
site, not in front setback area), >140
shrubs
11.5 Parking lot
landscape
When parking lot
abuts a street.
Min. 1 shrubs of
every 3 linear feet of
landscaped area,
Min. 1 tree per 40
linear feet
X X Roughly 10 shrubs within 18’ of
landscaped area in hotel lot adjacent to
proposed road.
11.6 Parking lot
interior
landscape (>15
spaces)
1 island with 1
broadleaf tree for
every 10 parking
spaces min. Double
islands require 2
trees.
Min. 10% of total
parking lot area.
Rows of parking
spaces must
terminate in a
landscape area
X X
Hotel lot – 99 spaces, roughly 1 single
island and 2 double islands (at end of
double row) = 5 total
Required landscaped islands: ~ 10
Playground lot – 28 spaces, no islands
Required: 2-3 landscaped islands
Applicant to confirm % of landscaped area
in hotel parking lot
11.7
Buffer yardr
Required where
multi-family
dwelling abuts a
townhouse
dwelling
Interior side/rear
setback
10’ in width, fencing,
1 trees for every 30
linear feet, 1 shrubs
for every 3 linear feet
of landscaped area
X X
Between Townhouses #1 – 6 and Building
#1. Approx 90 linear feet of landscaped
area – 3 trees provided (compliant), <30
shrubs (not compliant)
Between Multifamily buildings and
Townhouses #31 – 46 + playground and
lot. Approx. 600’ linear feet of landscaped
area – No trees in the setback area
adjacent to multifamily building
(noncompliant, however there are 30+
between the buildings and townhouses
within the ROW);
>200 shrubs in setback (compliant)
Key Requirement Info Provided Compliant Comments
9
Yes No Yes No
11.8 Street trees 1 per 40 linear feet
lot frontage along
street in tree belt
X X TREE BELT - That part of the street or
highway not covered by sidewalk or other
paving, lying between the property line
and that portion of the street or highway
usually used for vehicular traffic (Urban
and Community Forest Master Plan)
Proposed Station Park Avenue is approx.
1,217’ in length.
1217/40 = ~30 trees x 2 sides of street =
60 trees.
Provided: >60 trees along ROW
All trees planted within the tree belt and
anywhere within the right-of-way require
approval of the Department of Public
Works.
11.9 Tree preservation
Applies to multi-
family dwellings
and non-
residential uses
Existing significant
trees to be preserved
to the maximum
extent feasible.
Applicant has indicated that 671
significant trees exist on site, and 52 of
those trees will be preserved.
Tree survey and preservation and
replacement plan required.
Existing significant trees preserved on a
site that are of good health are credited
towards fulfillment of the landscape
requirements of this Ordinance with the
exception of required parking lot islands.
Every significant tree that is preserved
within a required landscape area is
credited as two required trees. A tree may
only be credited once. 11.9.D.
11.9 Construction
Protection
Defer to City Engineer.
Construction and tree protection must
comply with the following:
-ANSI A300 (Part 5)-2012: Management of
Trees and Shrubs During Site Planning, Site
Development, and Construction, most
current edition.
-International Society of Arboriculture -
Best Management Practices (BMP) -
Managing Trees During Construction, most
current edition.
Public Improvements (15)
15.3 Natural land
characteristics
Areas unsuitable for
development
Defer to City Engineer.
15.3 Natural land
characteristics
Preservation of
natural features
Defer to City Engineer.
15.6 Infrastructure
improvements
Sanitary sewer
(Chapter 231)
Defer to City Engineer.
15.6 Infrastructure
improvements
Water supply
(Chapter 231)
Defer to City Engineer.
15.7
Utilities
Easements for public
utilities
If utilities are to be dedicated to the City,
executed easements to the City and LOC
associated with proposed work is
required.
15.8
Open space
preservation and
recreation land
Offering of min. 10%
of subject parcel(s)
for recreational use.
X
Need additional information.
Combination of land and fee in lieu is
permitted.
Key Requirement Info Provided Compliant Comments
10
Yes No Yes No
Stormwater Management (17)
17.4 Basic SWPPP required for residential
development disturbing 1 to 5 acres
Disturbance plan shows over 5 acres of
total disturbance but not more than 5
acres at any one time (max disturbance at
one time ~4.8 acres).
Item deferred to City Engineer.
17.4 Full SWPPP required for residential
development disturbing more than 5 acres
17.4 Basic SWPPP required for nonresidential
and mixed-use development disturbing .25
to .49 acre
17.4 Full SWPPP required for nonresidential and
mixed-use development disturbing .5 to
.99 acre
17.4 Full SWPPP required for nonresidential and
mixed-use development disturbing 1 acre
or more
Public Realm (18)
18.3 New blocks must not exceed 1,000’ in
length unless approved by DPW.
X X Block length <1,000’ in length
18.4A Complete Streets Plan set needs to be reviewed against the
City’s Complete Streets Plan.
18.5 Sidewalk and multi-use path requirements Plan needs to be reviewed against the
Saratoga Greenbelt Trail Plan, Complete
Streets Plan, and any other relevant
plans/policies.
Project includes installation of sidewalks.
Must be reviewed against City engineering
standards and be approved by DPW.
18.7 Bicycle lane design requirements X Bike lanes are not proposed as part of this
project. Can be required by the Planning
Board based on the Complete Streets Plan
18.8.A. ROW types x x Park Station Avenue to be classified. Likely
Local Street: Neighborhood Two-Lane
Divided Street.
18.8.B. ROW dimensional requirements X X Proposed street complies with the Local
Street: Neighborhood Two-Lane Divided
Street dimensional requirements.
Note: proposed street excludes a center
lane (10’ width).
Other Comments:
Planning Board may want to require cross access and maintenance agreements be executed between the various
proposed parcels on the project site.