HomeMy WebLinkAbout20250254 198 S Broadway Construction Application**HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED**
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
CITY HALL - 474 BROADWAY
•%/c�RPORATEO
SARATOGA SPRINGS, NEW YORK 12866-2296
�9��
TEL: 518-587-3550 X2533
www.saratoga-sptings.org
APPLICATION FOR:
ARCHITECTURAL / HISTORIC REVIEW
APPLICANT(S) * OWNER(S))(Ynot applicant
Name Stephen Chindamo
Address 198 South Broadway
Saratoga Springs, NY 12866
Phone 518-681-9544 /
Email staysaratoga@gmail.com
Identify primary contact person: ® Applicant ❑ Owner ❑ Attorney/Agent
I'FOR OFFICE USEI
2-0 -z5 0 2�y
(Application #)
(Date received)
(Project Title)
Staff Review
ATTORNEY/AGENT
* An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question.
Applicant's interest in premises:
PROPERTY INFORMATION
® Owner ❑ Lessee
Property Address/Location: 198 South Broadway
April 2014
Date Acquired by Owner:
Current Zoning District: < /,/C
Type of Review: 0 Architectural
Summary description of proposed action:
motel on site
❑ Under option to lease or purchase
Tax Parcel #: 165.83 2 59 -
(for example: /65.52 - 4 - 37)
Property use: ❑ Residential 19 Non-residential/mixed-use
❑ Historic ❑ Extension/modification (of current approval)
Installation of commerical above ground Swim Spa for use of guests of
Has a previous application been filed with the DRC for this property?
❑ No ® Yes — date(s)? 4/10/2024
-App. No.(s)? 20240130
Revised 0112021
A "complete" application consists of 1 hard copy (originao , and I electronic copy of application &ALL other
materials as required below:
New Construction / Additions
® Color photographs showing site/exterior details of existing structures and adjacent properties
® A detailed scaled site plan is essential for achieving minimal zoning compliance, depicting both current and planned structures
along with all building projections such as decks, porches, steps, roof overhangs, and chimneys. This site plan must show all
setbacks from property boundaries and any easements, in addition to the dimensional and bulk standards relevant to the zoning
district on 17"x11" sheet,
❑ Elevation drawings showing design of all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture
& lamp type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible
® Floor plans for proposed structure; on sheet no larger than 2'x3'— smaller permitted if legible
❑ Product literature, specifications and samples of proposed materials and colors
Change in exterior building materials (windows, doors, roof, siding, etc.), or color (in non-residential districts only)
❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features
❑ Elevation drawings showing all sides of existing & proposed construction — label dimensions, colors, materials, lighting (fixture & lamp
type, wattage), etc. - include compass bearing & scale; no larger than 2'x3' sheet — smaller permitted if legible
❑ Product literature, specifications and samples of proposed materials and colors
Within front yard setbacks in Historic Districts onlx (Front setbacks: UR 1 & INST-HTR=30'; URA4=25; UR-2, UR-3 & NCUD-1= I0)
- Installation, removal or change in material of drive- and walkways
- Installation or removal of architectural, sculptural or vegetative screening over 3' in height
- Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter)
For any of above:
❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties
❑ Site plan showing existing & proposed construction: include property lines & dimensions, required & proposed setbacks & lot
coverage, site features (fences, walks, trees, etc.) street names, compass bearing & scale; no larger than 2'x3' sheet — smaller
preferred if legible
❑ Product literature, specifications and samples of proposed materials and colors
Si,gnage / Awnings
❑ Color photographs showing site/exterior details of existing structures, and adjacent properties
❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I "x17"
❑ Scaled illustration of proposed sign/awning structure and lettering (front view & profile): include all dimensions of structure; type,
dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware
❑ Descriptions, specifications of proposed lighting including fixture & lamp type, wattage, mounting method, and location
❑ Product literature, specifications and samples of proposed materials and colors
Demolition
❑ Color photographs showing site/exterior details of existing structures, and of adjacent properties
❑ Site plan showing existing and any proposed structures - include dimensions, setbacks, street names, compass bearing, and scale
❑ Written description of reasons for demolition and, in addition:
❑ For structures of "architectural/historical significance", demonstrate "good cause" why structure cannot be preserved
❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a
"contributing" structure in a National Register district (contact City staff), provide plans for site development following demolition -
include a timetable and letter of credit for project completion
Telecommunication facilities
❑ Color photographs showing site/existing structures, and of adjacent properties
❑ Site plan showing existing and proposed structures: include dimensions, setbacks, street names, compass bearing, and scale
❑ Scaled illustration of proposed structures: include all dimensions; colors, materials, lighting, mounting details
❑ Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact
assessment and existing and proposed vegetative screening
Revised O112021
Request for extension of current approval
❑ Identify date of original DRC approval: Current expiration date: Org. App. No.
❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood.
SEQR Environmental Assessment Form
❑ Applicants proposing the following must complete "Part I" of the SEQR Short Environmental Assessment Form (available here:
http://www.dec.ny.,qov/docs/permits ej operations pdf/seafpartone.pd9:
- Construction or expansion of a multi -family residential structure (4 units +)
- Construction or expansion (exceeding 4,000 sq. ft. gross floor area) of a principal or accessory non-residential structure
- Telecommunications facility, radio antennae, satellite dishes
- Demolition
Disclosure
Does any City officer, employee or family member thereof have a financial interest (as defined by General Municipal Law
Section 809) in this application?
® No ❑ Yes - If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this
application.
Certification
/we, the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appear4nce
before the Design Review Commission.
By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying
documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing
false or misleading information is grounds for immediate denial of this application.
I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property
associated with this application for purposes of conducting any necessary site inspections relating to this application.
Furthermo P, I/we�ree to meet all requirements under Article VI I for Historic Review or Article VIII for Architectural
Review of, a ZorCode of the City of Saratoga Springs.
Date: 'S
(applicant signature)
Date:
(applicant signature)
If applicant is not the currently the owner of the property, the current owner must also sign.
Owner Signature: Date:` 2 r
f; V
Owner Signature:
Date:
Revised 01/2021
CITY OF SARATOGA SPRINGS
DESIGN REVIEW COMMISSION
City Hall - 474 Broadway
- Saratoga Springs, New York 12866
C0 PORATO Tel: 518-587-3550 x2533
www.saratoga-springs.org
INSTRUCTIONS
ARCHITECTURAL/ HISTORIC REVIEWAPPLICATION
1. ELIGIBILITY: An applicant to the Design Review Commission for Architectural Review or Historic Review
must be the property owner(s) or lessee, or have an option to lease or purchase the property in question.
2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is
complete. The DRC will only consider properly completed applications that contain 1 original and 1
digital version of the application and ALL other required materials as indicated on the application.
HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!!
3. ACTIONS REQUIRING REVIEW:
Architectural Review District
Historic Review District
• any exterior changes that require a building permit
• Installation or exterior change to a structure requiring a
• any change in exterior building materials
building or demolition permit
• a new, or change to an existing, sign or sign structure
• any material change to exterior of a structure including:
• demolition of a structure
- addition or removal of exterior architectural features
- installation, removal or material changes to exterior
Within a non-residential zoning district:
building elements such as roof, siding, windows, doors,
• a change in exterior building color
porches, etc.
• installation of an awning
- enclosure or screening or buildings openings such as
windows, doors, porches, etc.
- installation of utility, mechanical or misc. accessory
structures to the exterior of a building such as HVAC
equipment, solar panels, wind turbines, radio/satellite
transmission/reception devices, etc.
■ Within a front yard setback:
- installation, removal or material changes to drive- or
walkways
- installation or removal of architectural, sculptural or
vegetative screening that exceeds 3' in height
- installation of accessory utility structures or
radio/satellite transmission/reception devices over 2' in
diameter
• a change in exterior building color within a non-
residential zoning district
• a new, or change to an existing, sign or awning
• installation of telecommunications facilities
EOrdinary maintenance or repair that does not involve a change in material, design or outer appearance
pt from Historic or Architectural Review.
Revised 01/2021
4. DESIGN GUIDELINES:
The Design Review Commission will evaluate whether the proposed action (construction, alteration or
demolition) is compatible with existing structures and surrounding properties using the following criteria:
• Height — consistent with historic form and context of site and surrounding properties
• Scale — relationship of structure and its architectural elements to human size, form, perception
• Proportion — relationship among building elements including front facade, windows, and doors
• Rhythm — pattern resulting from repeating building elements such as door/window openings, columns,
arches, and other facade elements
• Directional Expression — compatibility with horizontal & vertical expression of surrounding structures
• Massing & Open Space — relationship of structure to open space between it and adjoining buildings
• Setback —compatibility with surrounding structures
• Compatibility of the following with surrounding structures/properties:
Major building elements (storefronts, doors, windows, roof)
Building materials
Color— (in non-residential zoning districts only)
5. DECISIONS: The Design Review Commission may approve, approve with conditions, or disapprove an
application. The DRC may impose appropriate conditions and safeguards in connection with its approval
including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied
DRC application on the grounds of hardship.
Application approvals shall expire within 18 months of the filing date unless the project has sufficiently
commenced (i.e. buildingidemolition permits obtained and construction/alteration begun). Applicants may
request up to 2 extensions if requested before expiration date of prior approval.
6. AGENDA DATE: Check City's website (%yww.saratoga-springs.org) for meeting dates. Applications are
placed on an agenda on first -come, first -served basis as determined by the completeness of the application.
7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance"
REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT.
ADDITIONAL INFORMATION:
More detailed information on Architectural Review, Historic Review and the Design Review Commission
responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at
http://www.saratoga-springs.org/544/Zoning-Ordinance.
Revised 01/2021
City of Saratoga Springs
'h ?• r-
City Hall -474 Broadway
Saratoga Springs, New York 12866
_ =t
Tel:516-587-3550 www.saratoga-spdngs.org
�„ o.o,,co `
Office of Planning & Economic Development
Application to City Council FEE
Comprehensive Plan amendment $1,800 + $300/acre
Zoning Ordinance amendment $800 + $300/acre
Planned Unit Development PUD amendment $800 + $300/acre
Application to Zoning Board of Appeals
Use Variance
$1,400 + $50/app
Area Variance - Residential (1 & 2 Family)
$350/1st var +$50/app +$150/ea add variance
Area Variance - 3+ Family and Commercial
$1000/1st var + $50/app+ $200/ ea add variance
Interpretations
$650 + $50/app
Post Work Application Fee
Application Fee x 2 + $50/app
Variance extensions
50% of Application fee + $50/app
Residential Structures - 1 or 2 Family Principal or Accessory Structure
Materials Change -roof, windows, siding
$75
Facade Change-removal/addition of windows, doors, porch $150
Addition or new construction
$300
Approval Extension or Modification
50% of application fee
3 + /Multi -Family, Comm, Mixed -Use Principal or Accessory Structure
Materials Change -roof, windows, siding, paint color
$150
Signs, Awnings
$150
Facade Change-removal/addition of windows, doors, porch $300
Addition or new construction
$650
Approval Extension or Modification
50% of application fee
Application to Planning Board
Special Use Permit
$1200 + $50/app
Temporary Use Permit
$500
Special Use Permit - extension
$400
Special Use Permit - modification
$550 + $50/app
Site Plan Review - incl. PUD:
Sketch Plan
$400 per sketch
Site Plan Full
Residential
$400 + $250/unit
Non-residential
$800 + $150/1000 sf
Administrative SPR
Residential
$400
Non-residential
$800
Extension
Residential
$250
Non-residential
$350
Subdivision - Incl. PUD:
Sketch Plan
$400 per sketch
Preliminary Approval
Residential: 1-5 lots
$700 + $50/app
Residential: 6-10 lots
$1100 + $50/app
Residential: 11-20 lots
$1450 + $50/app
Residential: 21+ lots
$1800 + $50/app
Residential - extension
$350
Final Approval
Residential
$1,550 + $200/lot + $50/app
Non- Residential
$2,400/lot + $50/app
Final Approval Modification
Residential
$400 + $50/app
Non- Residential
$800 + $50/app
Final Approval Extension
Residential
$250
Non- Residential
$350
Uther:
Lot Line Adjustment/Subdivision Administrative Action
$400
Letter of Credit - modification or extension
$400
Letter of Credit - collection
up to 1 % of LoC
Recreation Fee
$2000/lot or unit
Land Disturbance
$750 + $35/acre
Watercourse/Wetland Permit
$750
SEQRA EIS Review Draft & Final
TBD
I
Stag Saratoga Swim Spa
Side of Exist Building Showing Spa Location
Page 1
View From Across Street
l' i !' f l' ' !'
View from adjacent sidewalk at Corner of Property
Page 2
O�
PAVED
of
ENTRANCE
o�
�I0
o•
(s))
EX15T VINYL
I
8' FENCE
I
5191,14,5011W
_
_.._.._.. ..I
�50.0'
��:�
Lu o
z cf�
SOUTH 15ROADWAY
ALLEY
EX15T PAVED
PARKING
50.01 IRON FEN
EX15T
PATIO
EX15T BRICK 510EW
C1
SWIM 5PA W/
SPA COVER
5' DECK 50% OF
PERIMETER
\
5' WIDE STAIRS/
RAILING &
—EX15T
LOCKA5LE GATE
PT 6x6
O' FROM
CURB
li
VERHEAD
nnr
i iI Site Plan
SPI01 Scale: I" = 20'-0" 0 20 40 FT
na
51TE PLAN 13A5ED ON "MAP OF SURVEY OF LANDS OF
CARRIAGE HOUSE LODGING, LLC" BY W.J. RJOARKE
A55OCIATE5, DATED MAY 17, 2018, JOB # 18-18 AND
ARCHITECT'5 FIELD MEASUREMENTS
WOOD 5TOCKADE
FENCING NEXT TO
STONE/PLANTER/
RETAINING WALL
LIST OF DRAWINGS
ID
DRAWING NAME
C101
51TE PLAN
A101
FIRST FLOOR PLAN
A201
DETAIL @ SWIM SPA STAIRS
IT 15 A VIOLATION OF LAW FOR ANY
PERSON, UNLE55 DIRECTED BY A
REGISTERED ARCHITECT, TO ALTER
TH15 DOCUMENT IN ANYWAY.
ALTERATIONS MUST HAVE THE
SEAL OF THE ARCHITECT AFFIXED
WITH A OE5CRIPTION OF THE
ALTERATION, SIGNATURE AND DATE.
d°
3��
zc:
De
O
0
z�LE
Q�
V)
°0Q�_MU
00
0
11
BRICK EXISTING 51DEWALL
PLAN @ Swim
m
Stairs
GRA5FABLE HADRAIL
CEDAR TREAD5 & R15ER5
CEDAR GUARDRAIL MIN 38"
ABOVE WALKING 5URFACE
5ELF CL051NG
LOCKABLE GATE
ALL CEDAR STAIR5 AND,
PLATFORM TO BE 5TAINED TO
MATCH 5WIM5 FA WALL
3.0 ft
EX15TING
PAVED
PARKING
IT 15 A VIOLATION OF LAW FOR ANY
PERSON, UNLE55 DIRECTED DY A
REGISTERED ARCHITECT, TO ALTER
THI5 DOCUMENT IN ANYWAY.
ALTERATIONS MUST HAVE THE
SEAL OF THE ARCHITECT AFFIXED
WITH A DESCRIPTION OF THE
ALTERATION. SIGNATURE AND DATE.
3��
=.
De0�
�E
i�
V)
Q
.i3
M
�
20�==N
0
N
o
W
Q
LL
\\\\\\\\\\\\\\\\\\I
46" HIGH SWIM 5PA
GUARDRAIL TO BE
MIN 5b" HIGH FROM
N051NG
SELF CLO5EING AND
LOACKA13LE GATE —
2x6 0 12" OC
(2) 2x8
2x12 5TRINGER
@12"OC —
6x6 1'05T
4" CONC 5LA13 �-- GALV METAL P05T 13A5E
ALL EXTERIOR LUMBER
TO 5E CEDAR 5TAINED TO MATCH SWIM 51"A WALL
;DETAIL @ Swim Spa Stairs
AZO�lSca e: 3/8 , = 7o,, 0 1.0
IT 15 A VIOLATION OF LAW FOR ANY
PER50N, UNLESS DIRECTED BY A
REGISTERED ARCHITECT, TO ALTER
THIS DOCUMENT IN ANYWAY.
ALTERATIONS MUST HAVE THE
SEAL OF THE ARCHITEGT AFFIXED
WITH A DESCRIPTION OF THE
ALTERATION, SIGNATURE AND DATE,
E 1
LL..
VZ' V
E I
U)
p
t
�
20'^^�==N
to
o
O
3 �
n
'
F
iN
G
LL
E
�
IU
I