Loading...
HomeMy WebLinkAbout20250222 102 Nelson Ave Verizon Utility Pole Application **HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED** [FOR OFFICE USE] (Application#) CITY OF SARATOGA SPRINGS r. DESIGN REVIEW COMMISSION . CITY HALL-474 BROADWAY (Date received) � SARATOGA SPRINGS, NEW YORK 12866-2296 °�PoRartio ��� TEL: 518-587-3550 X2533 www.seratoga-springs.org (Project Title) APPLICATION FOR: ARCHITECTURAL/HISTORIC REVIEW Staff Review APPLICANT(S)* OWNER(S) (/fnotappl/can ATTORNEY/AGENT Name Cellco Partnership d/b/a Verizon Wirele: National Grid Young/Sommer LLC Address 1275 John Streeet, Suite 100 300 Erie Blvd. West 5 Palisades Drive, Suite 300 West Henrietta, New York 14586 Syracuse, New York 13202 Albany, New York 12205 Phone 585-321-5390 / / 518-438-9907/ Email dbrennan@youngsommer.com Identify primary contact person: ❑ Applicant ❑ Owner 8 Attorney/Agent *An applicant must be the property owner, lessee, or one with an option to lease or purchase the property in question. Applicant's interest in premises: ❑ Owner B Lessee ❑ Under option to lease or purchase PROPERTY INFORMATION Property Address/Location: Pole#NG11 /VZ2 -Adj to 102 Nelson Ave Tax Parcel #: NSA (for example: 165.52—4—37) Date Acquired by Owner: Current Zoning District: U R-1 Property use: a Residential a Non-residential/mixed-use Type of Review: ❑ Architectural a Historic ❑ Extension/modification (of current approval) Summary description of proposed action: Collocation of an unmanned public utility/personal wireless service facility on the existing wooden utility pole with the antenna tip 37.0 +/-ft. in height. Has a previous application been filed with the DRC for this property? e No ❑ Yes—date(s)? -App. No.(s)? Revised 01/2021 **A "complete" application consists of 1 hard copy (original) , and I electronic copy of application &ALL other materials as required below: New Construction /Additions O Color photographs showing site/exterior details of existing structures and adjacent properties O Site plan,drawn to scale,showing existing&proposed construction, property lines&dimensions, required&proposed setbacks&lot coverage,site features(fences,walks,trees, etc.);on no larger than 2'x3'sheet—smaller preferred if legible O Elevation drawings showing design of all sides of existing&proposed construction—label dimensions, colors, materials, lighting(fixture &lamp type,wattage), etc. -include compass bearing&scale; no larger than 2'x3'sheet—smaller permitted if legible ❑ Floor plans for proposed structure;on sheet no larger than 2'x3'—smaller permitted if legible O Product literature,specifications and samples of proposed materials and colors Change in exterior building materials (windows, doors, roof, siding, etc.), or color(in non-residential districts only) ❑ Color photographs showing site/exterior details of existing structures and that illustrate affected features ❑ Elevation drawings showing all sides of existing&proposed construction—label dimensions,colors, materials, lighting(fixture&lamp type,wattage),etc. - include compass bearing&scale; no larger than 2'x3' sheet—smaller permitted if legible ❑ Product literature, specifications and samples of proposed materials and colors Within front yard setbacks in Historic Districts onlx (Front setbacks:UR-1 &INST-HTR=30';UR-4=25';UR-2,UR-3&NCUD-1=10') - Installation, removal or change in material of drive- and walkways - Installation or removal of architectural, sculptural or vegetative screening over 3' in height - Installation of accessory utility structures or radio/satellite transmission/reception devices (more than 2' diameter) For any of above: ❑ Color photographs showing site/exterior details of existing structures,and of adjacent properties ❑ Site plan showing existing&proposed construction: include property lines&dimensions, required&proposed setbacks&lot coverage,site features(fences,walks,trees, etc.) street names, compass bearing&scale; no larger than 2'x3'sheet—smaller preferred if legible ❑ Product literature, specifications and samples of proposed materials and colors Si2na2e/Awnings ❑ Color photographs showing site/exterior details of existing structures,and adjacent properties ❑ Plan showing location of proposed sign/awning structure on building/premises: no larger than I I"x 17" ❑ Scaled illustration of proposed sign/awning structure and lettering(front view&profile): include all dimensions of structure;type, dimensions and style of lettering or logo; description of colors, materials, mounting method and hardware ❑ Descriptions,specifications of proposed lighting including fixture&lamp type,wattage, mounting method,and location ❑ Product literature, specifications and samples of proposed materials and colors Demolition ❑ Color photographs showing site/exterior details of existing structures,and of adjacent properties ❑ Site plan showing existing and any proposed structures-include dimensions,setbacks, street names,compass bearing, and scale ❑ Written description of reasons for demolition and, in addition: ❑ For structures of"architectural/historical significance",demonstrate"good cause"why structure cannot be preserved ❑ For structures in an architectural district that might be eligible for listing on National Register of Historic Places, or for a "contributing"structure in a National Register district(contact City staff), provide plans for site development following demolition- include a timetable and letter of credit for project completion Telecommunication facilities 8 Color photographs showing site/existing structures,and of adjacent properties 8 Site plan showing existing and proposed structures: include dimensions,setbacks,street names,compass bearing,and scale 8 Scaled illustration of proposed structures: include all dimensions;colors, materials, lighting, mounting details 8 Consult Article 240-12.22 of the City's Zoning Ordinance and City staff to ensure compliance with requirements for visual impact assessment and existing and proposed vegetative screening Revised O1/2021 Request for extension of current approval ❑ Identify date of original DRC approval: Current expiration date: Org.App. No. ❑ Describe why this extension is necessary and whether any significant changes have occurred either on the site or in the neighborhood. SEQR Environmental Assessment Form 8 Applicants proposing the following must complete"Part I"of the SEQR Short Environmental Assessment Form (available here: http://www.dec.ny.gov/docs/permits ei operations pdf/seafp art one.pd- -Construction or expansion of a multi-family residential structure(4 units +) -Construction or expansion (exceeding 4,000 sq.ft.gross floor area)of a principal or accessory non-residential structure -Telecommunications facility, radio antennae,satellite dishes - Demolition Disclosure Does any City officer, employee or family member thereof have a financial interest(as defined by General Municipal Law Section 809) in this application? 8 No ❑ Yes- If yes, a statement disclosing the name, residence, nature, and extent of this interest must be filed with this application. Certification /we,the property owner(s), or purchaser(s)/lessee(s) under contract, of the land in question, hereby request an appearance before the Design Review Commission. By the signature(s) attached hereto, I/we certify that the information provided within this application and accompanying documentation is, to the best of my/our knowledge, true and accurate. I/we further understand that intentionally providing false or misleading information is grounds for immediate denial of this application. I/we hereby authorize the members of the Design Review Commission and designated City staff to enter the property associated with this application for purposes of conducting any necessary site inspections relating to this application. Furthermore, I/we agree to meet all requirements under Article VII for Historic Review or Article VIII for Architectural Review of the Zoning Code of the City of Saratoga Springs. Date:3/21 /25 (applicant signature) Date: (applicant signature) If applicant is not the currently the owner of the property,the current owner must also sign. Owner Signature: Date: Owner Signature: Date: Revised 01/2021 CITY OF SARATOGA SPRINGS r DESIGN REVIEW COMMISSION City Hall -474 Broadway Saratoga Springs, New York 12866 c kP a Tel:518-587-3550 x2533 o artio � www.saratoga-springs.org INSTRUCTIONS ARCHITECTURAL/ HISTORIC REVIEW APPLICATION I. ELIGIBILITY:An applicant to the Design Review Commission for Architectural Review or Historic Review must be the property owner(s) or lessee, or have an option to lease or purchase the property in question. 2. COMPLETE SUBMISSIONS: Applicants are encouraged to work with City staff to ensure that an application is complete. The DRC will only consider properly completed applications that contain 1 original and 1 digital version of the application and ALL other required materials as indicated on the application. HANDWRITTEN APPLICATIONS WILL NOT BE ACCEPTED!! 3. ACTIONS REQUIRING REVIEW: Architectural Review District Historic Review District • any exterior changes that require a building permit • Installation or exterior change to a structure requiring a • any change in exterior building materials building or demolition permit • a new, or change to an existing, sign or sign structure • any material change to exterior of a structure including: • demolition of a structure -addition or removal of exterior architectural features - installation, removal or material changes to exterior Within a non-residential zoning district: building elements such as roof, siding, windows, doors, • a change in exterior building color porches, etc. • installation of an awning - enclosure or screening or buildings openings such as windows, doors, porches, etc. - installation of utility, mechanical or misc. accessory structures to the exterior of a building such as HVAC equipment, solar panels, wind turbines, radio/satellite transmission/reception devices, etc. ■ Within a front yard setback: - installation, removal or material changes to drive- or walkways - installation or removal of architectural, sculptural or vegetative screening that exceeds 3' in height - installation of accessory utility structures or radio/satellite transmission/reception devices over 2' in diameter • a change in exterior building color within a non- residential zoning district • a new, or change to an existing, sign or awning • installation of telecommunications facilities Note—Ordinary maintenance or repair that does not involve a change in material, design or outer appearance is exempt from Historic or Architectural Review. Revised 01/2021 4. DESIGN GUIDELINES: The Design Review Commission will evaluate whether the proposed action (construction, alteration or demolition) is compatible with existing structures and surrounding properties using the following criteria: • Height— consistent with historic form and context of site and surrounding properties • Scale— relationship of structure and its architectural elements to human size, form, perception • Proportion — relationship among building elements including front fagade, windows, and doors • Rhythm — pattern resulting from repeating building elements such as door/window openings, columns, arches, and other fagade elements • Directional Expression —compatibility with horizontal &vertical expression of surrounding structures • Massing& Open Space— relationship of structure to open space between it and adjoining buildings • Setback—compatibility with surrounding structures • Compatibility of the following with surrounding structures/properties: - Major building elements (storefronts, doors, windows, roof) - Building materials - Color— (in non-residential zoning districts only) 5. DECISIONS:The Design Review Commission may approve, approve with conditions, or disapprove an application. The DRC may impose appropriate conditions and safeguards in connection with its approval including nature/quality of materials, manner of construction, and design. An applicant may appeal a denied DRC application on the grounds of hardship. Application approvals shall expire within 18 months of the filing date unless the project has sufficiently commenced (i.e. building/demolition permits obtained and construction/alteration begun). Applicants may request up to 2 extensions if requested before expiration date of prior approval. 6. AGENDA DATE: Check City's website (www.saratoga-springs.org) for meeting dates. Applications are placed on an agenda on first-come, first-served basis as determined by the completeness of the application. 7. APPLICATION FEE (NON-REFUNDABLE): Make checks payable to the "Commissioner of Finance". REFER TO THE CURRENT FEE WORKSHEET INCLUDED IN THIS DOCUMENT. ADDITIONAL INFORMATION: More detailed information on Architectural Review, Historic Review and the Design Review Commission responsibilities may be found in the City's Zoning Ordinance available in City Hall and on the City's web site at http://www.saratoga-springs.org/544/Zoning-Ordinance. Revised 01/2021 Young / Sommer LLc ATTORNEYS AT LAW EXECUTIVE WOODS,FIVE PALISADES DRIVE,ALBANY,NY 12205 Phone:518-438-9907•Fax:518-438-9914 www.youngsommer.com David C.Brennan, Esq. Writer's Telephone Extension: 224 dbrennan@youngsommer.com March 21, 2025 Via Federal Express Mark Graham Administrative Assistant for OPED City of Saratoga Springs 474 Broadway Saratoga Springs,New York 12866 RE: Cellco Partnership d/b/a Verizon Wireless Application for DRB Approval Utility Pole#NG 11 NZ 2 -Adjacent to 102 Nelson Ave. and Wright St. Dear Mr. Graham: Please find enclosed an application to the Design Review Board for a proposal to add a wireless small cell antenna and equipment to an existing utility pole in the state right of way. Also enclosed is a check in the amount of$650.00 for the application fee. We look forward to discussing this further with the Design Review Board at an upcoming meeting. In the meantime, if you have any questions concerning this letter or the enclosed materials,please contact me at your convenience. Very truly yours, 4D,,S ,,o— &,.— David C. Brennan, Esq. Encl. DESIGN REVIEW BOARD CITY OF SARATOGA SPRINGS,SARATOGA COUNTY,NEW YORK In the Matter of the Application of CELLCO PARTNERSHIP d/b/a Verizon Wireless Utility Pole No. NG 11/VZ 2 Adjacent to 102 Nelson Avenue and Wright Street Saratoga Springs,New York 12866 APPLICATION FOR DESIGN REVIEW BOARD APPROVAL and STATEMENT OF INTENT Submitted by: Verizon Wireless Margaret Hayes,Manager-Network Real Estate 1275 John Street,Suite 100 West Henrietta,New York 14586 (585) 321-5390 Tectonic Engineering&Surveying Consultants,P.C. Steven Matthews,P.E. 36 British American Blvd,Suite 101 Latham,New York 12110 (518) 783-1630 Network Building+ Consulting Nico Facey,Site Acquisition Specialist 1777 Sentry Parkway W VEVA 17,Suite 400 Blue Bell,Pennsylvania 19422 (347) 712-9444 Please Direct All Correspondence To: Young/Sommer LLC David C. Brennan,Esq. Executive Woods Five Palisades Drive Albany,New York 12205 (518)438-9907 Dated: March 21,2025 DESIGN REVIEW BOARD OF THE CITY OF SARATOGA SPRINGS SARATOGA COUNTY,NEW YORK In the Matter of the Application of CELLCO PARTNERSHIP d/b/a Verizon Wireless Premises: Utility Pole No. NG 11 /VZ 2-Adjacent to 102 Nelson Ave. and Wright St. Saratoga Springs,New York 12866 STATEMENT OF INTENT and APPLICATION FOR DESIGN REVIEW BOARD APPROVAL I. Purpose and Need CELLCO PARTNERSHIP d/b/a Verizon Wireless ("Verizon Wireless" or the "Applicant") proposes the collocation of an unmanned public utility/personal wireless service facility(a "communications facility") at the above location. More specifically,Verizon Wireless is proposing to add wireless telecommunications equipment to an existing utility pole. The Applicant proposes to add the following to the existing utility pole: a single, cylindrical antenna(approximately 24" tall x 14.6" in diameter) mounted at the top of the pole at a tip height of 37.0± feet) along with the installation of electric and telecommunications equipment on the utility pole at a minimum height of 8' above grade. The existing pole that is being utilized has a maximum height of 33.8± feet. The property is located in the right of way adjacent to 102 Nelson Avenue (at the intersection of Wright Street), City of Saratoga Springs, Saratoga County,New York(NG 2/VZ 2). [Zoning Site Plan Drawings of Tectonic Engineering &Surveying,PC at TAB 6]. Upon completion, the proposed facility will provide additional wireless network bandwidth and improved performance to the nearby roads and the surrounding neighborhood areas. More specifically, the radio-frequency objectives are to extend reliable wireless service along a 0.5±mile portion of Nelson Avenue generally between Lincoln Avenue and Gridley Street and extending into the homes and local roads from the west side of the track to Adams Street, including the drop off / pick up areas along Frank Sullivan Place and the 1863 Club entrance, main track parking lots along Nelson Avenue, The Trackside Grill, Horseshoe Inn and Mexican Connection Restaurants. Lastly, the proposed microcell is needed to add localized 4G/5G capacity to support Emergency Services,traffic control,and track and non-track public safety and security functions before, during and after larger track events (weekend crowds, Belmont, Travers,etc.). Verizon Wireless is considered a public utility for land use purposes under New York decisional law (Cellular Telephone Company v. Rosenberg', 82 N.Y.2d 364 [19931),and a provider of "personal wireless services" under the federal Telecommunications Act of 1996 (the "TCA"). 1 In Rosenberg,the State's highest Court determined that the ordinary variance standard is inapplicable and a cellular telephone company applying for relief need only show that (1) the relief is "required to render safe and adequate service,"and(2)there are"compelling reasons,economic or otherwise,"for needing the variance. Cellular Telephone Company v.Rosenberg, 82 N.Y.2d 364,372(1993). 1 Verizon Wireless' equipment will be in operation twenty-four (24) hours a day, seven (7) days a week,three hundred sixty-five (365) days a year. Verizon Wireless is applying for review by the Design Review Board.2 The proposed replacement pole is located in the UR-1 Zoning District. The facility is not located in the Architectural Review District or the Historic Review District. The proposed communications facility is unmanned and will be visited for routine maintenance purposes approximately two times per year (only as needed). As such, the project will not have any impact on existing water and sewage services. In addition, neither pedestrian nor vehicular access to the premises will be impacted [see Zoning Drawings at TAB 6]. II. Compliance with City Requirements The proposed communications facility complies in all material respects with City requirements: 1. SEQRA: A Short Environmental Assessment Form is attached as TAB 2. 2. Minimum Visual Impact: As noted above,Verizon Wireless' proposed facility is designed to have a minimum possible visual effect on the surrounding community and neighborhood [TAB 3]. 3. Site Plan: The Applicant has provided a Zoning Site Plan that identifies the proposed improvements [TAB 5]. Based upon the foregoing, Verizon Wireless respectfully submits that approval is appropriate in this case. III. Conclusion The communications facility proposed is a public necessity under Rosenberg in that it is required to render adequate and safe service to this area of the City of Saratoga Springs. In an effort to supplement existing telecommunications services to this area of the City,while reducing the need for a new tower or macro cell collocation,Verizon Wireless has identified an appropriate location for the deployment of a small cell facility. Verizon Wireless' existing macro cell sites in the area do not provide adequate coverage and capacity to this area of the City. The City of Saratoga Springs will be lacking adequate and safe capacity, and the failure to approve this application will eliminate the means to provide necessary capacity. This, combined with the federal mandate to expeditiously deploy advanced wireless services across the nation and Verizon Wireless' FCC licenses to provide such services in the City of Saratoga Springs, demonstrates that Verizon Wireless'facility is a public necessity.Without the construction of the communications facility proposed, the public would be deprived of an essential means of communication, which, in turn, would jeopardize the safety and welfare of the community and traveling public. 2 For the reasons set forth herein,Verizon Wireless believes that its project complies in all material respects with the provisions of the City of Saratoga Springs Land Use Laws and,consistent with the application process established by the City for prior Small Cell applications, that no additional approvals or relief are required. To the extent that an additional approval or relief is required,Verizon Wireless submits these materials in support of such approval(s). 2 The small cell facility will not be noticeable to the traveling public or nearby property owners. The communications system proposed has been sited to have the least practical adverse visual effect on the environment, and any resulting impact(s) may properly be considered as minimal in nature and scope. Attached to this Application and Statement of Intent are the following: 1) An Application for Architectural/Historic Review by the Design Review Board; 2) A Short Environmental Assessment Form; 3) Radio Frequency Analysis and Coverage Plots; 4) Photosimulations of the proposed installation and SEQRA Visual EAF Addendum; 5) Radio Frequency-Site Compliance Report;and 6) Project Zoning Drawings. Kindly place this matter on the agenda for discussion at the next available meeting of the Design Review Board. In the meantime, if you should have any questions or require any additional information concerning this project, I can be reached at (518)438-9907. Thank you for your consideration. Respectfully submitted, CELLCO PARTNERSHIP d/b/a Verizon Wireless David C. Brennan,Esq. Regional Local Counsel Dated: March 21,2025 3 Short Environmental Assessment Form Part I -Project Information Instructions for Completing Part 1—Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding,are subject to public review,and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item,please answer as thoroughly as possible based on current information. Complete all items in Part 1.You may also provide any additional information which you believe will be needed by or useful to the lead agency;attach additional pages as necessary to supplement any item. Part 1—Project and Sponsor Information Name of Action or Project: Cellco Partnership,d/b/a Verizon Wireless-Unmanned Wireless Facility-"Siros Project Location(describe,and attach a location map): Right-of-way adjacent to 102 Nelson Ave,City of Saratoga Springs,Saratoga County, NY 12866 Brief Description of Proposed Action: Cellco Partnership,d/b/a Verizon Wireless("Verizon Wireless"or"Applicant")is applying for permits for a proposed unmanned wireless communications facility on an existing wood utility pole on Wright St. The subject pole is located in the south side of the right-of-way of Wright St,0.07 miles east of Jackson st. In general,the installation consists of the following:One(1)antenna mounted at a centerline height of 36.0'above grade on an existing 33.8'tall wood pole. All accessory equipment,cabling and utility services(power and fiber)are proposed to be mounted to the wood pole. Name of Applicant or Sponsor: Telephone: (585)321-5390 Cellco Partnership,d/b/a Verizon Wireless;attn:Maggie Baughman E-Mail: margaret.hayes2@verizonwireless.com Address: 1275 John Street,Suite 100 City/PO: State: Zip Code: West Henrietta NY 14586 1. Does the proposed action only involve the legislative adoption of a plan,local law,ordinance, NO YES administrative rule,or regulation? If Yes,attach a narrative description of the intent of the proposed action and the environmental resources that ❑ may be affected in the municipality and proceed to Part 2. If no,continue to question 2. 2. Does the proposed action require a permit,approval or funding from any other government Agency? NO YES If Yes,list agency(s)name and permit or approval:City of Saratoga Springs-Design Review Board approval;Building ❑ permit 3. a.Total acreage of the site of the proposed action? <0.0001 acres b.Total acreage to be physically disturbed? 0 acres c.Total acreage(project site and any contiguous properties)owned or controlled by the applicant or project sponsor? <0.0001 acres 4. Check all land uses that occur on,are adjoining or near the proposed action: 5. ❑Urban ❑✓ Rural(non-agriculture) ❑ Industrial ❑✓ Commercial ❑✓ Residential(suburban) ❑✓ Forest ❑ Agriculture Aquatic ❑✓ Other(Specify): Saratoga Race Track ❑Parkland Page 1 of 3 5. Is the proposed action, NO YES N/A a. A permitted use under the zoning regulations? ❑ ❑� ❑ b. Consistent with the adopted comprehensive plan? ❑ RI ❑ NO YES 6. Is the proposed action consistent with the predominant character of the existing built or natural landscape? ❑ ❑✓ 7. Is the site of the proposed action located in,or does it adjoin,a state listed Critical Environmental Area? NO YES If Yes,identify: ❑� ❑ NO YES 8. a. Will the proposed action result in a substantial increase in traffic above present levels? ❑ ❑ b. Are public transportation services available at or near the site of the proposed action? ❑� ❑ c. Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed ❑ action? Rl- 9. Does the proposed action meet or exceed the state energy code requirements? NO YES If the proposed action will exceed requirements,describe design features and technologies: ❑ ❑✓ 10. Will the proposed action connect to an existing public/private water supply? NO YES If No,describe method for providing potable water: Potable water service is not required since the proposed facility is an unmanned facility. ❑✓ ❑ 11. Will the proposed action connect to existing wastewater utilities? NO YES If No,describe method for providing wastewater treatment: There will be no wastewater generated since the proposed facility is an unmanned facility. ❑� ❑ 12. a.Does the project site contain,or is it substantially contiguous to,a building,archaeological site,or district NO YES which is listed on the National or State Register of Historic Places,or that has been determined by the ❑ Commissioner of the NYS Office of Parks,Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? Union Avenue Historic District ❑ ❑ b.Is the project site,or any portion of it,located in or adjacent to an area designated as sensitive for archaeological sites on the NY State Historic Preservation Office(SHPO)archaeological site inventory? 13. a. Does any portion of the site of the proposed action,or lands adjoining the proposed action,contain NO YES wetlands or other waterbodies regulated by a federal,state or local agency? ❑� ❑ b.Would the proposed action physically alter,or encroach into,any existing wetland or waterbody? ❑� ❑ If Yes,identify the wetland or waterbody and extent of alterations in square feet or acres: Page 2 of 3 14. Identify the typical habitat types that occur on,or are likely to be found on the project site. Check all that apply: ❑Shoreline ❑✓ Forest ❑Agricultural/grasslands ❑ Early mid-successional ❑Wetland ❑ Urban ❑✓ Suburban 15. Does the site of the proposed action contain any species of animal,or associated habitats,listed by the State or NO YES Federal government as threatened or endangered? Frosted Elfin, Karner Blue ❑ ❑✓ 16. Is the project site located in the 100-year flood plan? NO YES ❑✓ ❑ 17. Will the proposed action create storm water discharge,either from point or non-point sources? NO YES If Yes, ❑ a. Will storm water discharges flow to adjacent properties? ❑ ❑ b. Will storm water discharges be directed to established conveyance systems(runoff and storm drains)? ❑ ❑ If Yes,briefly describe: 18. Does the proposed action include construction or other activities that would result in the impoundment of water ' NO YES or other liquids(e.g.,retention pond,waste lagoon,dam)? If Yes,explain the purpose and size of the impoundment: ❑ ❑ 19. Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste NO YES management facility? If Yes,describe: ❑ ❑ 20.Has the site of the proposed action or an adjoining property been the subject of remediation(ongoing or NO YES completed) for hazardous waste? If Yes,describe: ❑ ❑ I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Applicant/sponsor/name: nS,teven Matthews,agent on behalf of applicant Date:3/11/25 m"Signature: ^� m Title: Director of Engineering PRINT FORM Page 3 of 3 EAF Mapper Summary Report Tuesday, March 11, 2025 2:31 PM Disclaimer: The EAF Mapper is a screening tool intended to assist 1 1 project sponsors and reviewing agencies in preparing an environmental 15n.77 3�1, :.7 3 3'I assessment form(EAF).Not all questions asked in the EAF are k {T answered by the EAF Mapper.Additional information on any EAF 1 77.-3- 16 7r7-3- p � question can be obtained by consulting the EAF Workbooks. Although 66.77 �`�7 the EAF Mapper provides the most up-to-date digital data available to _2�6 I, , �: 1 :77 1 DEC,you may also need to contact local or other data sources in order to obtain data not provided by the Mapper.Digital data is not a t 79 +. substitute for agency determinations. 17'�!2'I :3,.1 :�9.21'13-4 Sourd .2'1-2-5 0 .I,-3 2 AxYsk K ingatm fYfondn S a ra toga p r1 n gs `= Toronto '7 9.21-2 40 Horn iu'an RoO"ter F �!+ .,Buffalo NexYnri+ }' d lb any .21-2 39 179.-1 1 1 79.21-2-50 7 .21 2 38 r Sc.Ur:es;Esr, HERE Garrni^, L{:=.{ Irt-?!i ; 11.9;- E-:V.xroXU ill R RC an, Esri Japai7, METI, Esri Chip f �" ;: -I•_.�a+,' NGCC. ft;DpuStreetNlap :-rh:r..F-r. Ar--. t^�: S _ !212ti35 14 2E 'tlrY'f1 = �;1=II:_ _ . . " .I-IJ-t;' Lser}d�P�ir�ul�i ;. Esri HEREG-i -,I- -1 � !Y. 4iYM hiimh Part 1 /Question 7 [Critical Environmental No Area] Part 1 /Question 12a [National or State Yes Register of Historic Places or State Eligible Sites] Part 1 /Question 12b [Archeological Sites] No Part 1 /Question 13a [Wetlands or Other No Regulated Waterbodies] Part 1 /Question 15 [Threatened or Yes Endangered Animal] Part 1 /Question 15 [Threatened or Frosted Elfin, Kanner Blue Endangered Animal - Name] Part 1 /Question 16 [100 Year Flood Plain] Digital mapping data are not available or are incomplete. Refer to EAF Workbook. Part 1 /Question 20 [Remediation Site] No Short Environmental Assessment Form - EAF Mapper Summary Report 1 verizon / Network Engineering 175 Calkins Road Rochester,New York 14623 Siros Micro Cell Communications Facility Radio Frequency Analysis Verizon is proposing to collocate a new microcell facility on an existing utility pole at the intersection of Nelson Ave and Wright St in the City of Saratoga Springs, Saratoga County, New York. This microcell is needed to improve coverage and network performance at/near the Saratoga Race Track western entrance including main ingress/egress routes Nelson Ave and Wright St. Due to heavy network usage during summer months and track season, and patches of dense tree canopy along the local roads and homes west of the track, Verizon's existing neighboring macro sites are not capable of providing reliable mobile voice and data services to this targeted improvement area. The proposed microcell is also needed to supplement capacity for local police, traffic control and other EMS personnel at times when massive network usage after large track events has caused network access issues (call blocking) and unusable data speeds specifically along Wright St, Frank Sullivan PI, and Nelson Ave, and the intersections of Nelson Ave with Lincoln Ave, Crescent St and Gridley St. General Methodology— Network Design/Micro Cell Placement The proposed micro cell is a significantly paired down version of a typical macro cell (i.e., a standard 3- sectored antenna array placed on a tall tower, building or water tank as commonly seen on wireless communications facilities in Saratoga Springs and the surrounding area - for example the 245 ft. tall guyed tower off West Ave (from Lincoln Ave near Saratoga Springs High School)). The proposed micro cell consists of radios and other ancillary equipment inside an enclosure mounted approximately 12 ft. above ground level and connected via coaxial cable to a 2 ft. tall canister antenna mounted on top of the existing 33.8±ft. tall utility pole at the southwest corner of the Nelson Ave/Wright St intersection. Verizon's specific"Siros" microcell objectives are to extend reliable wireless service along a 0.5± mile portion of Nelson Ave generally between Lincoln Ave and Gridley St and extending into the homes and local roads from the west side of the track to Adams St., including the drop off/ pick up areas along Frank Sullivan PI and the 1863 Club entrance, main track parking lots along Nelson Ave, The Trackside Grill, Horseshoe Inn and Mexican Connection Restaurants. Lastly, and as mentioned previously, the proposed Siros microcell is needed to add localized 4G/5G capacity to support Emergency Services, traffic control, and track and non- track public safety and security functions before, during and after larger track events (weekend crowds, Belmont, Travers, etc.). Verizon's closest wireless facilities to the proposed micro cell are its "Saratoga Gaming & Raceway"site 0.5± miles south at Saratoga Casino Hotel, its "Saratoga City Hall" site 0.9± miles northwest on the Hampton Inn & Suites Hotel, and its "Oklahoma Track" site 1.0± miles northeast on The Grove at Saratoga Apartments rooftop. Due to distance, patches of dense tree canopy in/around the neighborhoods west of the track, but mostly the massive amount of wireless network generated in/around the track during racing season, coverage and capacity from these and all other neighboring wireless facilities (particularly in Verizon's mid- frequency channels in the 1900 MHz — 3500 MHz range) is unable to the reliably serve the targeted Nelson Ave improvement area. In researching the existing co-locatable structures at and generally within 1 block of the Nelson Ave / Wright St intersection, the existing utility pole on the west side of Nelson Ave where it intersects with Wright St was identified as a potential candidate to achieve Verizon's intended coverage and capacity objectives. The specific pole was chosen as it is positioned near the center of the targeted approximately 0.5-mile section of Nelson Ave where it has an unobstructed view north to Lincoln Ave and south to Crescent St and Gridley St. A microcell at this location is also able to provide needed network capacity during and after track events from the 1863 Club and track's west entrance, across the main track parking areas along Nelson Ave, the nearby restaurants and track drop off/ pick up locations along Frank Sullivan PI, and foot and vehicle traffic west to 2 approximately Adams St (including the homes across the areas mentioned above). With no other utility poles or other existing tall structures in the immediate area offering the same desirable characteristics, Verizon is proposing to collocate its microcell facility on Pole# NG 11/VZ 2. Calculated coverage from the proposed Siros microcell facility is shown in the street and aerial maps at Figure 1 below. When viewing the maps, the blue-shaded area illustrates new and/or improved coverage from the proposed facility at Verizon's 2100 MHz frequency band, and the blue semi-circle labeled "Siros" is placed at the proposed micro cell location (on the existing utility pole). As the results demonstrate, the proposed micro cell will successfully cover the targeted section of Nelson Ave generally from Lincoln Ave to Gridley St and extending west of the track's west entrance along Wright St. When complete, mobile devices attempting to access or remain connected to Verizon's network will seamlessly and reliably connect via the Siros microcell site, effectively improving mid-band 4G/5G coverage and capacity across the targeted area. 2100 MHz Coverage 95 dB.RSRP _P oposed N Coverage _h 1 t f eT + T tJ re i1r Yes � r se�15 .yam: T uamor'-`.': x a n w verizon✓ verizonv Figure 1 — Expected Coverage and Performance Improvement Area (Blue-Shaded Region) from the Proposed Siros Microcell Conclusion To summarize, Verizon is proposing to install a small canister antenna (measuring 24 in. high by 14.6 in. wide) on top of an existing 33.8± ft. tall utility pole with associated radios and ancillary equipment inside an enclosure installed 12 ft above ground level on the pole. The proposed microcell is needed to provide reliable coverage and supplement wireless network capacity along Nelson Ave near the Saratoga Race Track west entrance; coverage and capacity is limited in this area due to heavy network usage during summer months (particularly for large track events) and distance to Verizon's neighboring wireless facilities. The proposed facility will resolve this gap in reliable service. Date: March 11, 2025 Prepared by: �ZCk a4 v4a'.P Rick Andras Radio Frequency(RF) Design Engineer Verizon Wireless 617.20 Appendix B State Environmental Quality Review VISUAL EAF ADDENDUM This form may be used to provide additional information relating to Question 11 of Part 2 of the Full EAF. (To be completed by Lead Agency) Distance Between Visibility Project and Resource (in Miles) 1. Would the project be visible from: 0-'/4 /4-'/z /z-3 3-5 5+ ! A parcel of land which is dedicated to and available ❑ ❑ ❑ ❑ ❑ to the public for the use, enjoyment and appreciation of natural or man-made scenic qualities? ! An overlook or parcel of land dedicated to public ❑ ❑ ❑ ❑ ❑ observation, enjoyment and appreciation of natural or man-made scenic qualities? ! A site or structure listed on the National or State ❑ ❑ ❑ ❑ ❑ Registers of Historic Places? ! State Parks? ❑ ❑ ❑ ❑ ❑ The State Forest Preserve? ❑ ❑ ❑ ❑ ❑ ! National Wildlife Refuges and State Game Refuges? ❑ ❑ ❑ ❑ ❑ ! National Natural Landmarks and other outstanding ❑ ❑ ❑ ❑ ❑ natural features? ! National Park Service lands? ❑ ❑ ❑ ❑ ❑ ! Rivers designated as National or State Wild, Scenic ❑ ❑ ❑ ❑ ❑ or Recreational? ! Any transportation corridor of high exposure, such ❑ ❑ ❑ ❑ ❑ as part of the Interstate System, or Amtrak? ! A governmentally established or designated interstate ❑ ❑ ❑ ❑ ❑ or inter-county foot trail, or one formally proposed for establishment or designation? ! A site, area, lake, reservoir or highway designated as ❑ ❑ ❑ ❑ ❑ scenic? ! Municipal park, or designated open space? ❑ ❑ ❑ ❑ ❑ ! County road? ❑ ❑ ❑ ❑ ❑ ! State road? ❑ ❑ ❑ ❑ ❑ Local road? Nelson Ave, Wright St, Frank Sullivan PI R] ❑ ❑ ❑ ❑ 2. Is the visibility of the project seasonal?(i.e., screened by summer foliage, but visible during other seasons) ❑yes ❑✓No 3. Are any of the resources checked in question 1 used by the public during the time of year during which the project will be visible? Zyes ❑No DESCRIPTION OF EXISTING VISUAL ENVIRONMENT 4. From each item checked in question 1, check those which generally describe the surrounding environment. Within *%mile *1 mile Essentially undeveloped ❑ ❑ Forested ❑✓ ❑ Agricultural ❑ ❑ Suburban Residential ❑✓ ❑ Industrial ❑ ❑ Commerical ❑ Urban ❑ ❑ River, Lake, Pond ❑ Cliffs, Overlooks ❑ ❑ Designated Open Space ❑ ❑ Flat ❑✓ ❑ Hilly ❑ ❑ Mountainous ❑ ❑ Other El NOTE:add attachments as needed Saratoga Race Track 5. Are there visually similar projects within: *%mile QYes ❑No 1 mile 0 Yes ❑No 2 miles 0 Yes ❑No 3 miles 0 Yes ❑ No *Distance from project site is provided for assistance. Substitute other distances as appropriate. EXPOSURE 6. The annual number of viewers likely to observe the proposed project is 1.2 Million ? NOTE: When user data is unavailable or unknown, use best estimate. CONTEXT 7. The situation or activity in which the viewers are engaged while viewing the proposed action is: FREQUENCY Holidays/ Activity Daily Weekly Weekends Seasonally Travel to and from work O O O O Involved in recreational activities O O O O Routine travel by residents O O O O At a residence O O O O At worksite O O O O Other O O O O Reset �4 < , Sr AT MID iob K y - - I 'v y �,�• S_ � �fib� _ -� 4, Y n _ Tectonic • • w 4 - �° s Yam. 3�-! �'Y sR�. _,r ':���.sr•- r fLj: z r4r 'k 7. 40 STOP � 4 y r _ e A Y n _ Tectonic • • . mT " - _ 1 ,G r.Qii, f S lectonic Looking west near#102 Nelson Avenue P_2 Proposed equipment will be visible from this location 12397.060 i II' v - -.TectoniO Looking west near#102 Nelson Avenue S-2 Proposed equipment shown as visible from this location 12397.060 c Ycet Verizon Wireless Site Compliance Report Site name - Siros Site Name: Siros Site Address: 102 Nelson Ave, Saratoga Springs, NY, 12866 Structure Type: Utility Pole Report Information Report Date: March 7, 2025 Report Generated by: Mamta Verma Customer Contact: Rick Andras Compliance Statement Verizon Compliance Statement: Verizon wireless is compliant with FCC rules and regulations in all publicly accessible areas. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 circet USA Contents 1. Executive Summary........................................................................................................................................................3 2. Antenna Inventory .........................................................................................................................................................4 3. Analysis...........................................................................................................................................................................5 4. Appendix A: Reference Information...............................................................................................................................6 2 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 circet USA 1. Executive Summary Verizon Wireless has contracted with Circet USA, an independent Radio Frequency consulting firm,to determine if the proposed telecommunications facility is in compliance with Federal Communications Commission(FCC) rules and regulations regarding RF exposure as defined in 47 CFR§ 1.1307(b)and 1.1310. This document and the conclusions herein are based on the information provided by representatives of Verizon Wireless which is assumed to be true and correct. All information used in this report was analyzed to determine compliance in publicly accessible areas,in particular at ground level. The analysis evaluates the telecommunications facility with respect to the General Population/Uncontrolled Maximum Permissible Exposure (MPE)limits. Circet USA has taken into consideration the Verizon Wireless antenna system as well as any existing antenna systems at the subject location. Verizon Wireless final antenna count is(1)antenna. Based on the analysis, Circet USA has determined that: Verizon Wireless is compliant in all publicly accessible areas with the FCC rules and regulations governing human exposure to RF electromagnetic fields as described in 47 CFR§ 1.1307(b)and 1.1310. With the proposed Verizon Wireless antenna configuration in service,the composite exposure from this facility in all areas at ground level will be less than 1%of the General Population MPE limit, or over 100 times less than the maximum allowed exposure in publicly accessible areas. 3 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 circet USA 2. Antenna Inventory The table below contains data provided by Verizon Wireless representatives and/or gathered by Circet USA personnel. This data was used to perform the RF exposure analysis. Antenna Mech.Tilt Azimuth Frequency Elec.Tilt TotalGain ERP Ant ID Owner manufacturer Antenna model Height(ft) band HBW(°) VBW(°) power (') (') (') (Watts) (dBd) (Watts ) 1 Verizon JMAWireless CX200MI224-3Hxy 0 270 36 PCS1900 2 240 25 63.55 7.35 345.22 1 Verizon JMA Wireless CX200MI224-3Hxy 0 270 36 LTE 2100 2 240 25 190.6 7.35 1035.65 1 Verizon I JMAWireless 1 CX200MI224-3Hxy 1 0 270 36 4GHz 0 240 19.2 142.9 7.65 832.05 Notes:Each row with the some number in the Antenna ID column references the same physical antenna.Power values provided by the client and used in the analysis may be greater than what is initially deployed. 80%TDD Duty Cycle and 100%FDD Duty Cycle are used. Jumper/connector/coax power losses between RRHs and antenna: A WSIPCS: 2 dB C-band: 2.5 dB 4 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 �11} Circet USA 3. Analysis Circet USA has included the Verizon Wireless antenna system at the subject location in the analysis. All existing and proposed antennas are listed in the antenna table above.Engineering assumptions were used when specific antenna or operating parameter information was not available for the other existing collocated antennas (if applicable). Using this data, software modeling using IXUS software was performed for all transmitting antennas located at the site. Circet USA has assumed a 100%duty cycle and maximum radiated power. The site has been modeled with these assumptions to determine the maximum potential RF energy density at ground level. Circet USA believes this to be a worst-case analysis based on the best available data. As stated previously,based on this analysis,the calculated ground level exposure from the Verizon Wireless antenna system alone is less than 1%of the General Population MPE limit. Keep in mind that the FCC did not arbitrarily establish their own standards but rather adopted the recommendations of national and international organizations such as the National Council on Radiation Protection and Measurements (NCRP),the American National Standards Institute (ANSI) and the Institute of Electrical and Electronics Engineers(IEEE). These recommendations were developed by expert scientists and engineers following extensive evaluation of the potential biological effects from RF exposure. The FCC MPE limits are based on thresholds for known adverse effects,and they were designed to provide a substantial margin of safety. There is a safety factor of 50 built into the General Public MPE limits, and the predicted Verizon Wireless exposure levels are over 100 times below these very conservative limits. In cases where such compliance exists,the subject of electromagnetic field safety is preempted by the Telecommunications Act of 1996,which states: "No state or local government or instrumentality thereof may regulate the placement,construction, and modification of personal wireless service facilities on the basis of the environmental effects of radio frequency emissions to the extent that such facilities comply with the(Federal Communication) Commission's regulations concerning such emissions." The graph below provides a visual depiction of the rather insignificant electromagnetic field exposure contribution from the Verizon Wireless antenna system out to a distance of 500' from the base of the structure. This portrays how low the Verizon Wireless contribution is when compared to the General Population MPE limit. %General Public MPE vs Distance 120 100 a u 80 a m � a m 0 � 40 20 a 0 50 100 150 200 250 300 350 400 450 500 Distance(ft) •VZW MPE Contribution -FCC MPF Limit 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 �11} Cjrcet USA 4. Appendix A: Reference Information FCC Rules& Regulations All information used in this report was analyzed as a percentage of the MPE limits as detailed in 47 CFR§ 1.1310. The calculated power density at each sample point divided by the limit at each calculated frequency provides a result in%MPE. Summing the calculated%MPE from all contributors provides accumulative %MPE at a particular sample point.Wireless carriers use different frequency bands with varying MPE limits;therefore,it is useful to report results in terms of%MPE as opposed to power density. All results were compared to the FCC radio frequency exposure rules as detailed in 47 CFR§ 1.1307(b)to determine compliance with the MPE limits for General Population/Uncontrolled environments as defined below: Two Classifications for Exposure Limits Occupational—Applies to situations in which persons General Population—Applies to situations in which are"exposed as a consequence of their employment" persons are"exposed as a consequence of their and are'fully aware of the potential for exposure and employment may not be made fully aware of the potential can exercise control over their exposure". for exposure or cannot exercise control over their exposure". Generally speaking,those without significant and documented RF Safety&Awareness training would be in the General Population classification. Environment Classification Controlled —Applies to environments that are restricted Uncontrolled—Applies to environments that are or"controlled"in order to prevent access from members unrestricted or"uncontrolled"that allow access from of the General Population classification. members of the General Population classification. 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 �11} Cjrcet USA FCC Limits for Maximum Permissible Exposure (MPE) Plane-wave Equivalent Power Density 1000 —Occupational — -General Public E 100 U 10 CI N C L a 0.1 0.01 0 1 10 100 1,000 10,000 Frequency (MHz) The MPE limits defined in 47 CFR§ 1.13 10 and utilized in this analysis are outlined in the table and diagram below: Limits or Occupational/Controlled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength Strength S E 12, H 2,or S MHz E /m H)(A/m) (mW/cm2 minutes 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f 900/f2 * 6 30-300 61.4 0.163 1.0 6 300-1500 -- -- f/300 6 1500-100,000 -- -- 5 6 Limits or General Population/Uncontrolled Exposure Frequency Electric Field Magnetic Field Power Density Averaging Time Range Strength Strength S E 12, H 2,or S MHz E)(V/m) (H)(A/m) (mW/cm2 minutes 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f 180/f2 * 30 30-300 27.5 0.073 0.2 30 300-1500 -- -- f/1500 30 1500-100,000 -- -- 1.0 30 f=frequency in MHz * Plane-wave equivalent power density 1777 Sentry Parkway W. Building 11 • Suite 201 Blue Bell • PA • 19422 CELLCO PARTNERSHIP, d / b/ a verizon 1275 JOHN STREET, SUITE 100 WEST HENRIETTA, NY 14586 Tecton'i*c ■ PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. Tectonic Engineering Consultants, Geologists dt Land Surveyors, D.P.C. Project Contact Info 36 British American Blvd. Phone: (518) 783-1630 Suite 101 (800) 829-6531 Latham, NY 12110 www.tectonicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12397.060 LP SM NO. DATE ISSUE 0 12/2/24 FOR REGULATORY SIROS RELEASED BY DATE '(S OF NE 1- ��P FUZE ID#: 16085137 LU NO �_ ,o 08750-1 238 R�FESSIONP� UTILITY POLE NG 11 /VZ 2 SUMMARY OF MAKE READY WORK UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC SURVEYOR IS A VIOLATION OF SECTION SUBDIVISION 2 OF THE NEW YORK STATEE EDUCATION MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. LAW COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE 2. RAISE OPEN WIRE SECONDARY 18" TO 31'1 AND 29'7". RESULTING OF THE SIGNATURE AND AN ORIGINAL EMBOSSED SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF CLEARANCE TO POLE TOP = 32". THE PROFESSIONAL ENGINEER OR LAND SURVEYOR N SHALL NOT BE CONSIDERED VALID COPIES. � s SITE ADDRESS: ADJ TO 102 NELSON AVE 3. ON UTILITY POLE #10; RAISE OPEN WIRE SECONDARY 18". SARATOGA SPRINGS, NY 12866 SHT. DESCRIPTION REV REVISION 0 1 ° NO. NO DATE 4. INSTALL SINGLE POLE GROUND AND ROD PER 13-111 FOR ANTENNA MUNICIPALITY: CITY OF SARATOGA SPRINGS EQUIPMENT AND BOND NEUTRAL. ORIGINAL SIZE IN INCHES COUNTY: SARATOGA T-1 TITLE SHEET 0 12/2/24 NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. (22x34 FORMAT) CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION TAX MAP NUMBER: PUBLIC R.O.W. STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT 0 1 GN-1 GENERAL NOTES 0 12/2/24 SPECIFICATIONS. STRUCTURE COORDINATES: 43.071859° —73.774421° C-1 SITE PLAN & EQUIPMENT PLAN 0 12/2/24 1 LICENSE APPLICATION #SIROS/5000931238 WORK REQUEST #31060631 ORIGINAL SIZE IN INCHES (11 x17 FORMAT) SITE GROUND ELEVATION: 307'f AMSL C-2A MAKE READY SCOPE OF WORK 0 12/2/24 POLE OWNER: NATIONAL GRID/VERIZON C-213 POLE ELEVATION & DETAIL 0 12/2/24 UTILITY PROVIDERS SITE INFORMATION 3 C-3 POLE MOUNT DETAILS 0 12/2/24 ELECTRIC PROVIDER: NATIONAL GRID SIROS POLE #: NG 11/VZ 2 ESR #: XXXXXXX FUZE ID#: 16085137 ACCOUNT #: XXXXX-XXXXX APPLICANT: VERIZON WIRELESS E-1 ELECTRICAL & GROUNDING DIAGRAMS & DETAILS 0 12/2/24 PLANNER: TBD 1275 JOHN STREET, SUITE 100 PHONE: (XXX) XXX-XXXX M DG#: 5000931238 WEST HENRIETTA, NY 14586 CONTACT PERSON: MAGGIE BAUGHMAN FIBER: VERIZON SITE ADDRESS CONTACT PHONE: (585) 321 -5390 UTILITY POLE# NG 11 /VZ 2 Before You Dig, Drill Or Blast! ADJ TO 102 NELSON AVE r Dig Safely. CITY OF SARATOGA SPRINGS Saratoga r New York SARATOGA COUNTY UNDERGROUND FACILITIES V PROTECTIVE ORGANIZATION NY 12866 VICINITY I N TY MAP PROJECT SUMMARY CALL US TOLL FREE 1-800-962-7962 NY industrial code rule 753 requires no less than two SHEET TITLE working days notice,but not more than ten days notice. D RECT ONS PROJECT DESCRIPTION DIG SAFELY - NEW YORK TITLE SHEET DIRECTIONS TO SITE: THE PROPOSED WORK CONSISTS OF: FROM NORTH GREENBUSH SWITCH FACILITY, TURN LEFT ONTO US-4 . INSTALL (1 ) CELLULAR ANTENNA & ASSOCIATED EQUIPMENT ON DO NOT SCALE DRAWINGS N/N GREENBUSH RD. AT THE TRAFFIC CIRCLE, TAKE THE 1ST EXIT EXISTING POLE.ONTO US-4 N. TURN LEFT ONTO MORRISON AVE. TURN LEFT ONTO SHEET INDEX THESE DRAWINGS ARE FORMATTED FOR 22 x34 FULL SIZE AND 11 x17 SHEET NUMBER NY-378 W/HIGH ST. USE THE RIGHT LANE TO MERGE ONTO 1-787 N 0 INSTALL ELECTRICAL, TELCO AND CABLE ROUTING AS NECESSARY. VIA THE RAMP TO COHOES. TAKE I-87 N TO US-9 N IN MALTA. TAKE HALF SIZE. OTHER SIZED VERSIONS ARE NOT PRINTED TO THE SCALE EXIT 13N FROM 1-87 N. TAKE EXIT 13N TO MERGE ONTO US-9 N THIS SET OF PLANS SHALL NOT BE UTILIZED AS CONSTRUCTION DOCUMENTS SHOWN. CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS TOWARD BALLSTON SPA. MERGE ONTO US-9 N. TURN RIGHT ONTO UNTIL ALL ITEMS OF CONCERN HAVE BEEN ADDRESSED AND EACH OF THE & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE CRESCENT ST. TURN LEFT ONTO NELSON AVE. TURN LEFT ONTO DRAWINGS HAS BEEN REVISED AND ISSUED "FOR CONSTRUCTION". ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WRIGHT ST. THE SITE WILL BE ON THE LEFT. THE WORK OR BE RESPONSIBLE FOR SAME. T�l . ELECTRICAL NOTES LANTENNA MOUNTING NOTES GENERAL NOTES 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK SPECIFICATIONS, NEC AND ALL APPLICABLE LOCAL CODES. 1. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO ANSI/TIA-222-H-2017 "STRUCTURAL STANDARD FOR ANTENNA STATE BUILDING CODE, AND ALL OTHER APPLICABLE CODES AND verizon 2. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED. SUPPORTING STRUCTURES, ANTENNAS AND SMALL WIND TURBINE ORDINANCES. SUPPORT STRUCTURES". THE BUILDING CODE OF NEW YORK STATE, AND 2. CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH ALL 3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL CODES. CONDITIONS AFFECTING THE PROPOSED WORK AND MAKE PROVISIONS AS TO ACCESS TO EQUIPMENT IS NOT BLOCKED. THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR 2. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS 1275 JOHN STREET, SUITE 100 4. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE ACCORDANCE WITH ASTM A123 "ZINC (HOT-DIP GALVANIZED) COATINGS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED WEST HENRIETTA, NY 14586 REQUIREMENTS OF THE NEC. ON IRON AND STEEL PRODUCTS", UNLESS OTHERWISE NOTED. AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES 5. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE REQUIRED BY THE NEC. 3. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE COMMENCEMENT OF WORK. GALVANIZED IN ACCORDANCE WITH ASTM A153 "ZINC-COATING (HOT-DIP) ' 6. EACH END OF EVERY POWER, POWER PHASE CONDUCTOR (I.E., HOTS), GROUNDING, AND T1 ON IRON AND STEEL HARDWARE", UNLESS OTHERWISE NOTED. 3. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A Tectonic CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL DIAGRAMMATIC OUTLINE ONLY, UNLESS OTHERWISE NOTED. THE WORK SHALL TAPE (3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). 4. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR "REPAIR EXCEPTIONAL SERVICE. THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA. GALVANIZING IN ACCORDANCE WITH ASTM A780 REPAIR OF DAMAGED NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. Tectonic Engineering Consultants, Geologists & Land Surveym, G.P.C. AND UNCOATED AREAS OF HOT-DIP GALVANIZED COATINGS", USING COLD Project Contact Info GALVANIZING COMPOUND AS MANUFACTURED BY ZINGA-USA OR ZINC 4. DIMENSIONS SHOWN ARE TO FINISH SURFACES, UNLESS OTHERWISE NOTED. 36 British American Blvd. Phone: (518) 783-1630 7. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED. ALL EQUIPMENT SHALL BE Suite 101 (800) 829-6531 KOTE, OR ENGINEER APPROVED EQUAL WITH A MINIMUM METALLIC ZINC SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS Latham, NY 12110 www.tectonicengineering.com LABELED WITH THEIR VOLTAGE RATING, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT CONTENT OF 95% BY WEIGHT IN DRY FILM. DRY FINISHED COATING CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S). THICKNESS SHALL BE 3 MILS MINIMUM. REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS AND/OR WO NUMBER DRAWN BY REVIEWED BY DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A 8. PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) 5. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH DOUBLE NUTS AND CLARIFICATION FROM THE CARRIER'S AUTHORIZED REPRESENTATIVE OR THE 12397.060 LP SM SHALL BE CLEARLY LABELED. SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S ENGINEER PRIOR TO PROCEEDING WITH THE WORK. SPECIFICATIONS. I L NO. DATE ISSUE 9. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE 5. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR 0 12/2/24 FOR REGULATORY SINGLE CONDUCTOR (#14 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, 6. DESIGN OF THE ANTENNA MOUNTING BRACKETS, SUPPORTS, AND ALL MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, STRANDED COPPER CABLE RATED FOR 90°C (WET AND DRY) OPERATION; LISTED OR COMPONENTS THEREOF AND ATTACHMENT THERETO SHALL BE THE AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. RESPONSIBILITY OF THE MANUFACTURER. MANUFACTURER SHALL PROVIDE THE OWNER DRAWINGS DETAILING ALL COMPONENTS OF THE ASSEMBLY, 6. CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR INCLUDING CONNECTIONS, DESIGN LOADS, AND ALL OTHER PERTINENT IN WRITING AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY (#6 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN INSULATION, DATA. MANUFACTURER SHALL ALSO PROVIDE THE OWNER WITH A ITEMS NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. STRANDED COPPER CABLE RATED FOR 90°C (WET AND DRY) OPERATION; LISTED OR STATEMENT OF COMPLIANCE, INDICATING THAT THE ANTENNA SUPPORTS LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED, UNLESS OTHERWISE SPECIFIED. HAVE BEEN DESIGNED IN ACCORDANCE WITH ANSI/TIA-222-H 7. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER OF ALL STANDARDS. ALL SUBMISSIONS SHALL BEAR THE SIGNATURE AND SEAL PRODUCTS OR ITEMS NOTED AS "EXISTING" WHICH ARE NOT FOUND TO BE IN 11. POWER AND CONTROL WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK. THE FIELD. TYPE USE-2 CABLE (#14 AWG OR LARGER), 600 V, OIL RESISTANT RHW-2 OR XHHW-2, RELEASED BY DATE STRANDED COPPER CABLE RATED FOR 90°C (WET AND DRY) OPERATION; WITH OUTER 8. CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING THE BEST JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE SPECIFIED. CONSTRUCTION SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY STRUCTURAL NOTE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, 12. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE SEQUENCES, PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL WORK UNDER CONTRACT, UNLESS OTHERWISE NOTED. BE RATED FOR OPERATION AT NO LESS THAN 90°C. 1. THE VERIFICATION OF STRUCTURAL ADEQUACY AND DESIGN OF THE 9, ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT ATTACHMENTS MUST BE PERFORMED, PRIOR TO THE COMMENCEMENT EXPERIENCED WORKMEN IN ACCORDANCE WITH APPLICABLE CODES AND THE •(ti )F NE 13. ELECTRICAL METALLIC TUBING (EMT) OR RIGID METALLIC CONDUIT (RMC) SHALL BE USED OF CONSTRUCTION, BY A PROFESSIONAL ENGINEER LICENSED IN THE BEST ACCEPTED PRACTICE. ALL MEMBERS SHALL BE LAID PLUMB AND TRUE FOR EXPOSED OR CONCEALED LOCATIONS. STATE OF NEW YORK. AS INDICATED ON THE DRAWINGS. *� 14. ALL OUTDOOR EXPOSED CONDUIT SHALL BE PVC SCHEDULE 80 AND SHALL BE SUPPORTED 2. REFER TO STRUCTURAL ANALYSIS REPORT PREPARED BY XXXXXXXXXXX co ADEQUATELY. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, DATED XX/XX/XX. AND ADJACENT AREAS, THAT ARE LIKELY TO BE AFFECTED BY THE WORK 15. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED OUTDOORS, UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA REQUIREMENTS �.o Qer50� . WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. LFMC SHALL CONFORM TO NEC R�FESSIONP� ARTICLE 350. 11. CONTRACTOR SHALL COORDINATE HIS WORK AND SCHEDULE HIS ACTIVITIES AND 16. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND GROUNDING NOTES OWNERORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS OF THE APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 17. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN 12. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK WITH UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN GROUND TESTING AFTER CONSTRUCTION: THE WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS BEARING THE SEAL OF A LICENSED ENGINEER OR LAND ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC. AND ANY OTHER PORTIONS OF THE WORK. SURVEYOR IS A VIOLATION of SECTION EED SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION 1. AFTER COMPLETION OF CONSTRUCTION OF THE CELL SITE GROUND SYSTEM, LAW. 18. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE A POST INSTALLATION GROUND TEST SHALL BE PERFORMED BY THE 13. CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT THE OWNER COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE GALVANIZED OR EPDXY-COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED CONTRACTOR. THE CONTRACTOR SHALL DETERMINE THE GROUND AND CARRIER. OF THE SIGNATURE AND AN ORIGINAL EMBOSSED NEMA 3R (OR BETTER) OUTDOORS. RESISTANCE FOR ALL SITES AFTER INSTALLATION OF THE EARTH GROUND SEAL R ORIGINAL STAMP IN BLUE OR RED INK of THE PROFESSIONAL ENGINEER OR LAND SURVEYOR 19. IF REQUIRED, CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE SYSTEM. A PRELIMINARY EARTH RESISTIVITY TEST (3 POLE TEST OR 14. INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH SHALL NOT BE CONSIDERED VALID COPIES. AND COORDINATE REQUIREMENTS, SERVICE ROUTING, AND METER SOCKET TYPE WITH LOCAL CLAMP-ON-METER) SHALL BE PERFORMED PRIOR TO BACK FILLING ALL MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OR POWER COMPANY. TRENCHES AS SPECIFIED IN VERIZON NETWORK STANDARDS (NSTD46) AND WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 0 1 THE NATIONAL ELECTRIC CODE. 15. MAKE NECESSARY PROVISIONS TO PROTECT EXISTING SURFACES, EQUIPMENT, 20. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS. ORIGINAL SIZE IN INCHES 2. APPROVED MEASUREMENT METHODS FOR POST INSTALLATION GROUND IMPROVEMENTS, PIPING, ANTENNA AND ANTENNA CABLES. REPAIR ANY 21. CONTRACTOR SHALL LABEL ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC 110.16 AND TESTING SHALL BE ONE OF THE FOLLOWING METHODS: DAMAGE THAT OCCURS DURING CONSTRUCTION. (22x34 FORMAT) 110.24. A. FALL OF POTENTIAL METHOD - 3 POINT B. CLAMP-ON RESISTANCE TEST 16. REPAIR ALL EXISTING SURFACES DAMAGED DURING CONSTRUCTION SUCH 0 1 22. CONTRACTOR SHALL VERIFY THAT THE MAIN BONDING JUMPER AND GROUNDING ELECTRODE C. TOWER AND EXTERNAL CONDUCTOR TEST THAT THEY MATCH AND BLEND WITH ADJACENT SURFACES. CONDUCTOR IS INSTALLED PROPERLY AT SERVICE ENTRANCE. 3. A GROUNDING RESISTANCE TEST REPORT SHALL BE PREPARED UPON 17. KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DEBRIS ORIGINAL SIZE IN INCHES COMPLETION OF THE TESTING. THE TEST REPORT SHALL SHOW THE AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY (11 x17 FORMAT) 23. WHERE ELECTRICAL POWER IS TO BE SUB-FED FROM AN EXISTING DISTRIBUTION SYSTEM, RESISTANCE IN OHMS AT 40%, 52%, 62%, 72% AND 82% POINTS IN 10% OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN CLEAN CONDITION THE FOLLOWING SHALL APPLY: INTERVALS. RESISTANCE IS TO BE RECORDED AT EACH INTERVAL FOR AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. SITE INFORMATION A. CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND EACH POINT FOR FOUR (4) DIFFERENT DIRECTIONS UNTIL THERE IS A CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL PER N.E.C. ARTICLE 220. PLATEAU SEEN AT THE 62% POINT. TESTING SHOULD BE COMPLETED IN A COMPLETION OF CONSTRUCTION. SIROS B. CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE 220. MINIMUM OF TWO (2) DIFFERENT DIRECTIONS AT 90 DEGREES APART. 18. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD C. EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS RECORD THE AVERAGE OR MEAN AS THE RESISTANCE OF THE SITE AND PRIOR TO FABRICATION AND ERECTION OF ANY MATERIAL. ANY UNUSUAL FUZE ID#: 16085137 EQUIPMENT SUPPLYING IT. ENTER THIS ON THE POST RESISTANCE DATA CHART. CONDITIONS SHALL BE REPORTED TO THE ATTENTION OF THE ENGINEER. D. PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE M DG#: 5000931238 LOCATED IN EXISTING PANEL. 4. PROVIDE THE POST INSTALLATION - GROUND RESISTANCE TEST REPORT TO 19. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND THE REGIONAL PROJECT ENGINEER ACCOMPANIED BY THE POST INSPECTIONS AND PAY ALL REQUIRED FEES. SITE ADDRESS RESISTANCE DATE CHART. 5. USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL 20. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS UTILITY POLE# NG 11 A Z 2 THAN 2-ATRAVEL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. ALL PORTIONS OFRTHE BUIOLDOUTWITHIN AREA DUR NGTCONSTRUCTION DISTANCE TO ALL ADJ TO 102 NELSON AVE BENDS SHALL BE MADE WITH 12 RADIUS OR LARGER. 6. APPROVED ANTIOXIDANT COATINGS (I.E. CONDUCTIVE GEL OR PASTE) 21. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP CITY OF SARATOGA SPRINGS SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND DRAWINGS AND OTHER DOCUMENTATION SHALL BE TURNED OVER TO CARRIER CONNECTIONS. AT COMPLETION OF CONSTRUCTION. SARATOGA COUNTY 7. GROUNDING TEST SHALL BE TAKEN BEFORE A/C POWER, NEUTRAL/GROUND 22 AFTER ETE THEJOB DATEHOFL BE ACCEPTANCE BYD FOR A CARRIER.PANIYO WORK, MATERIALS,ROR NY 12866 BOND IS CONNECTED. EQUIPMENT FOUND TO BE DEFECTIVE DURING THAT PERIOD SHALL BE SHEET TITLE 8. ANTI-OXIDATION CONDUCTIVE COMPOUNDS ARE REQUIRED ON ALL GROUND CORRECTED IMMEDIATELY UPON WRITTEN NOTIFICATION AT NO ADDITIONAL CONNECTIONS. NO OX-ID (COSMOLINE GREASE BASED COMPOUND) SHALL COST TO CARRIER. GENERAL NOTES BE USED FOR COPPER TO COPPER CONNECTIONS. ZINC BASED COMPOUND 23. RIGGING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH STATE AND (GREY COLORED) OR APPROVED EQUAL SHALL BE USED FOR COPPER TO FEDERAL SAFETY REGULATIONS (OSHA). ENGINEER, CARRIER AND THE OWNER STEEL CONNECTIONS. SHALL BE HELD HARMLESS IN THE EVENT THE CONTRACTOR DOES NOT 9. ALL LUG CONNECTIONS & THEIR MATING SURFACES SHALL BE CLEANED FOLLOW SUCH SAFETY REGULATIONS. AND COATED WITH THE APPROPRIATE ANTI-OXIDIZING CONDUCTIVE 24. CONTRACTOR SHALL PROVIDE ACCESS TO THE SITE AND ASSIST THE RADIO SHEET NUMBER COMPOUND. IF A LUG CONNECTION IS TO BE SECURED DIRECTLY TO A EQUIPMENT VENDOR AND THE ANTENNA INSTALLATION CONTRACTOR AS THEY PAINTED SURFACE, THE PAINT SHALL BE REMOVED TO REVEAL BARE MAY REQUIRE. METAL AROUND THE AREA OF THE CONNECTION AND COATED WITH AN APPROPRIATE ANTI-OXIDATION CONDUCTIVE COMPOUNDS. 13tINOR H ORIENTATION 13 N t 1 . NORTH ORIENTATION ESTABLISHED WRIGHT STREET BY COMPASS OBSERVATION. EDGE OF DIRECTION OF TRAFFIC EXISTING CURB 1275 JOHN STREET, SUITE 100 WEST HENRIETTA, NY 14586 c� 0 2 U rectonic �y PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. Tectonic Engineering Consultants, Geologists & Land Surveyors, D.P.C. Project Contact Info 36 British American Blvd. Phone: (518) 783-1630 EXISTING Suite 101 (800) 829-6531 •' ' , ' I}r .� t GRASS AREA Latham, www.tectonicengineering.com ` + '' ►r am •f # *,{ *� .14 -}* WO NUMBER DRAWN BY REVIEWED BY f�'_ 12397.060 LP SM t% o \ �• oo N0. DATE ISSUE r ' I I 4 R 4 #, 0 12/2/24 FOR REGULATORY • 4 r , { Awk + 1M 4 4 F ' ,- `; '` EXISTING UTILITY '�;'� tcow ' POLE (TYP) ,y , _ � . EXISTING w 41 ' - STOP SIGN PROPOSED 1-1/2" CONDUIT All • •�' . • • i " ' `'r � - (FROM SECONDARY TO METER) • _ t• '- . PROPOSED METER • f } y� RELEASED BY DATE _ EXISTING t _ UTILITY POLE _ F N y� , PROPOSED 100A *moo �# LOAD CENTER \ — PROPOSED #2 m _ o VERTICAL GROUND 08750- ? PROPOSED 1-1/4" PVC RISER FOR AC CIRCUITS TO ANTENNAS '` — - ONw EXISTING UTILITY POLE# NG 10 / EXISTING CONCRETE UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN CRAISE OPEN WIRE SECONDARY BEARING THE SEAL OF A LICENSED ENGINEER OR LAND WRIGHT S SIDEWALK SURVEYOR IS A VIOLATION OF SECTION 7209 00 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION 18". RAISE EACH COMM LINE 1') OHW LAW. COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE OHW — OF THE SIGNATURE AND AN ORIGINAL EMBOSSED I \ SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR OHW _ - PROPOSED VERIZON WIRELESS \ \ EQUIPMENT PLAN SHALL NOT BE CONSIDERED VALID COPIES. - - EQUIPMENT ON EXISTING 2 UTILITY POLE# NG 11/VZ 2 \ sf C-1 SCALE: 3" = 1'-0" (11x17 SIZE) 0 1 1-1/2" = 1'-0" (22x34 SIZE) ORIGINAL SIZE IN INCHES (22x34 FORMAT) o I \\ \ r 0 1 Z vz- O EXISTING OVERHEAD 13t EXISTING I\ WIRE (TYP) N UTILITY POLE ORIGINAL SIZE IN INCHES I C- (11x17 FORMAT) SITE INFORMATION I I \ PROPOSED 1-1/2" CONDUIT 0 z (FROM SECONDARY TO METER) SIROS - PROPOSED #2 o U', VERTICAL GROUND PROPOSED VERIZON WIRELESS FUZE ID#: 16085137 I I \ \ PROPOSED 4" U—GUARD FOR 1" FIBER CONDUIT M DG#: 5000931238 I I \ AC CIRCUITS TO ANTENNAS SITE ADDRESS W �- UTILITY POLE# N G 11 AZ 2 PROPOSED FUJITSU PASSIVE 0 ADJ TO 102 NELSON AVE I = I '• � \ o O I o ,er� \ FIBER ENCLOSURE MOUNTED CITY OF SARATOGA SPRINGS 0 TO EXTERIOR OF SHROUD SARATOGA COUNTY 0 NOTE: 0 NY 12866 SITE INFORMATION BASED ON A SITE VISIT PERFORMED BY TECTONIC ENGINEERING PROPOSED VERIZON WIRELESS ° CONSULTANTS, GEOLOGISTS & LAND SURVEYORS D.P.C., ON 9/11 /24. EQUIPMENT SHROUD WITH PROPOSED SHEET TITLE RRH AND ASSOCIATED EQUIPMENT 0SITE PLAN & EQUIPMENT (SEE DETAIL 5/C-3) @ ° SITE PLAN PLAN C-1 SCALE: 1" = 80' (11x17 SIZE) 1" = 40' (22x34 SIZE) _ -- SHEET NUMBER 3 SHROUD PLAN VIEW C-1 SCALE: 3" = 1'-0" (11x17 SIZE) 1-1/2" = 1'-0" (22x34 SIZE) C�l SUMMARY OF MAKE READY WORK 1. FLAGGING REQUIRED. CONTRACTOR TO SET UP TRAFFIC MAINTENANCE FLAGGING PERSONNEL PER MUTCD REQUIREMENTS. 2. RAISE OPEN WIRE SECONDARY 18" TO 31'1 AND 29'7". RESULTING CLEARANCE TO POLE TOP = 32". 3. ON UTILITY POLE #10; RAISE OPEN WIRE SECONDARY 18". 1275 JOHN STREET, SUITE 100 WEST HENRIETTA, NY 14586 4. INSTALL SINGLE POLE GROUND AND ROD PER 13-111 FOR ANTENNA EQUIPMENT AND BOND NEUTRAL. NATIONAL GRID APPROVED CONTRACTOR TO PERFORM ALL WORK. CONTRACTOR TO REFER TO NATIONAL GRID OVERHEAD CONSTRUCTION rectonic STANDARD MANUAL FOR ALL DETAILS AND ATTACHMENT SPECIFICATIONS. PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. Tectonic Engineering Consultants, Geologists dt Land Surveyors, D.P.C. LICENSE APPLICATION #SIROS/5000931238 WORK REQUEST #31060631 Project t Info 36 Britisshh American Blvd. Phone: (518) 783-1630 Suite 101 (800) 829-6531 Latham, NY 12110 www.tectonicengineering.com WO NUMBER DRAWN BY REVIEWED BY 12397.060 LP SM TOP OF EXISTING UTILITY POLE TOP OF EXISTING UTILITY POLE NO. DATE ISSUE 33.8'± AGL 33.8'± AGL 0 12/2/24 FOR REGULATORY RAISE OPEN WIRE SECONDARY 18" RELOCATED SECONDARY TO 31'1 AND 29'7". RESULTING EXISTING SECONDARY ELECTRIC 31.1'± AGL CLEARANCE TO POLE TOP — 32" LINE TO BE RELOCATED PER EXISTING SECONDARY NATIONAL GRID REQUIREMENTS RELOCATED SECONDARY 29.6'± AGL (SEE 3/C-2A) 30.3'± AGL EXISTING SECONDARY RELOCATED SECONDARY 28.9'± AGL 29.6'± AGL RELEASED BY DATE EXISTING SECONDARY 28.3'± AGL EXISTING COMMUNICATION LINE EXISTING COMM LINE TO BE RELOCATED (BY OTHERS) OF NE 24.8'± AGL � M'� yp9 EXISTING FIBER LINE RELOCATED COMM LINE *C',� # 23.5'± AGL EXISTING FIBER LINE TO BE 23.5 ± AGL "' U) m w RELOCATED (BY OTHERS) RELOCATED FIBER LINE �_ 22.5 ± AGL I COMM LINE REATTACHMENTS q 0875o� ' TO BE DONE BY OTHERS (TYP) °FEsstio�P I 1 1 LLJ ' UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN J ' BEARING THE SEAL OF A LICENSED ENGINEER OR LAND O ' SURVEYOR IS A VIOLATION OF SECTION 7209 3 2' SUBDIVISION OF THE NEW YORK STATE EDUCATION CD LAW. z - . COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE ~ if- OF THE SIGNATURE ORIG ORIGINAL TAMP AN OR IGINAL S OR INK SEAL OR OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR X = SS, SHALL NOT BE CONSIDERED VALID COPIES. 0 1 ORIGINAL SIZE IN INCHES (22x34 FORMAT) 00 ORIGINAL SIZE IN INCHES (11x17 FORMAT) If EXISTING UTILITY POLE EXISTING UTILITY SITE INFORMATION I Al }. ` +` I #NG 11 /VZ 2 TO REMAIN POLE #NG 11 /VZ 2 H _ SIROS FUZE I D#: 16085137 M DG#: 5000931238 SITE ADDRESS UTILITY PO LE# N G 11 /VZ 2 rITSr- - ADJ TO 102 NELSON AVE CITY OF SARATOGA SPRINGS EXISTING GRADE EXISTING GRADE SARATOGA COUNTY STREET SIDE STREET SIDE NY 12866 SHEET TITLE MAKE READY SCOPE OF EXISTING POLE PHOTO 2 EXISTING UTILITY POLE ELEVATION 3 PROPOSED UTILITY POLE ELEVATION WORK C-2A SCALE: NTS C-2A SCALE: 3/16" = 1'-0" (11x17 SIZE) C-2A SCALE: 3/16" = 1'-0" (11x17 SIZE) 3/8" = 1'-0" (22x34 SIZE) 3/8" = 1'-0" (22x34 SIZE) SHEET NUMBER NOTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY verizo THE UTILITY PROVIDERS REQUIREMENTS. 1275 JOHN STREET, SUITE 100 WEST HENRIETTA, NY 14586 II III EXISTING COMM LINE II ' PROPOSED 4G ANTENNA rectonioc PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. (SEE DETAIL 1/C-3) Tectonic Engineering Consultants, Geologists dt Land Surveyors, D.P.C. TOP OF PROPOSED ANTENNA Project Contact Info EXISTING FIBER LINE 36 British American Blvd. Phone: (518) 829-6531 37.0'± AGL Site 101 c engi 829-6531 Latham, NY 12110 www.tectonicengineering.cam q PROPOSED ANTENNA I I WO NUMBER DRAWN BY REVIEWED BY PROPOSED POLE TOP ANTENNA 36.0'± AGL i 12397.060 LP SM MOUNT (SEE DETAIL 1/C-3) I 3 I N0. DATE ISSUE INSTALL RF "CAUTION" SIGNAGE 2'± BELOW TOP OF EXISTING UTILITY POLE 33.8 ± AGL PROPOSED ANTENNA SEE DETAIL 4C-3 I I 0 12/2/24 FOR REGULATORY ( / ) PROPOSED MOPT EXISTING SECONDARY I TERMINAL (BY OTHERS) 31 .1 '± AGL I CID EXISTING SECONDARY PROPOSED VERIZON WIRELESS 30.3'± AGL 4" U—GUARD (CABLES FROM RRH TO ANTENNA) I EXISTING SECONDARY III RELEASED BY DATE 29.6'± AGL PROPOSED WEATHERHEAD FOR POWER � I (CARLON P/N: E998H-CAR OR APPROVED EQUAL) PROPOSED 1-1/2" I _ PVC RISER FOR POWER PROPOSED 1 1/2" CONDUIT (FROM SECONDARY TO METER) (OPPOSITE SIDE OF POLE) cP��o� N�y�,yQ I I g T� 9 PROPOSED COAX CABLES TO EXISTING COMMUNICATION I * c 23.5'± AGL PROPOSED LC/UPC BIDI RUGGEDIZED FIBER ANTENNAS IN 4" MAX U—GUARD I JUMPER FROM THE PROPOSED MOPT TERMINAL z - EXISTING FIBER TO PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE aA 0$750'1 �2 II PROPOSED MOPT TERMINAL 22.5 ± AGL RofiEsstioN�'�` (BY OTHERS) PROPOSED LC/UPC BIDI RUGGEDIZED FIBER BOTTOM OF PROPOSED MOPT TERMINAL JUMPER FROM THE PROPOSED MOPT 20.2't AGL PROPOSED VERIZON WIRELESS EQUIPMENT UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN TERMINAL TO PROPOSED FUJITSU PASSIVE SHROUD (COMMSCOPE PN: SSC-760249586X1 X BEARING THE SEAL of A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 FIBER ENCLOSURE WITHIN 1" CONDUIT OR EQUAL) (SEE DETAIL 5/C-3) SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW. THISWITHOUT A PROPOSED VERIZON WIRELESS 3 OFFP HIES E OF SIGNATUREANDENT AN ORIGINAL EMBOS EID SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF EQUIPMENT SHROUD WITH PROPOSED C-1 PROPOSED FUJITSU PASSIVE THE PROFESSIONAL ENGINEER OR LAND SURVEYOR RRH & ASSOCIATED EQUIPMENT FIBER ENCLOSURE MOUNTED SHALL NOT BE CONSIDERED VALID COPIES. (COMMSCOPE PN: SSC-760249586X1 X TO EXTERIOR OF SHROUD OR EQUAL) (SEE DETAIL 5/C-3) PROPOSED FUJITSU PASSIVE FIBER ENCLOSURE 0 1 MOUNTED TO EXTERIOR OF SHROUD ORIGINAL SIZE IN INCHES 2 (22x34 FORMAT) C-2B PROPOSED RUGGEDIZED FIBER JUMPERS TO 0 1 BOTTOM OF PROPOSED EQUIPMENT Q Q RRHs AND MMUs IN THE SHROUD (TYP OF 2) 2 12.0'± AGL (MINIMUM) ORIGINAL SIZE IN INCHES PROPOSED 1-1/4" PVC RISER FOR C 1 (11x17 FORMAT) AC CIRCUITS TO ANTENNAS BOTTOM OF PROPOSED LOAD CENTER PROPOSED EATON BRP12B100R LOAD CENTER 10.0'± AGL (MINIMUM) r LI I SITE INFORMATION OR APPROVED EQUAL (SECURE TO POLE SIROS USING UNISTRUT OR APPROVED BOTTOM OF PROPOSED METER PROPOSED EATON BRP12B100R FUZE ID#: 16085137 MANUFACTURER RECOMMENDED HARDWARE) 8.0'± AGL (MINIMUM) LOAD CENTER OR APPROVED EQUAL PROPOSED RF "INFORMATION" BOTTOM OF PROPOSED RF SIGNAGE (ON OPPOSITE SIDE OF POLE) M DG#: 5000931238 SITE ADDRESS SIGNAGE SEE DETAIL 4 C-3 I 8.0'± AGL MINIMUM ( / ) (MINIMUM) PROPOSED 1-1/2" LIQUIDTIGHT PROPOSED METER MILBANK P/N: U2048-RL OR (METER TO LOAD CENTER) UTILITY POLE# NG 11 /VZ 2 APPROVED EQUAL (SECURE TO POLE USING ADJ TO 102 NELSON AVE ERICKSON SERIES PBAL MOUNTING BRACKET OR ELECTRIC COMPANY APPROVED EQUAL) 111 01 CITY OF SARATOGA SPRINGS PROPOSED HIGH IMPACT EXISTING UTILITY POLE SARATOGA COUNTY PVC CABLE COVER (BLACK) EXISTING GRADE PROPOSED METER MILBANK P/N: NY 12866 STREET SIDE EXISTING GRADE U2048-RL OR APPROVED EQUAL (SECURE SHEET TITLE 0.0'± AGL TO POLE USING ERICSSON SERIES PBAL MOUNTING BRACKET OR APPROVED EQUAL) POLE ELEVATION & DETAIL UTILITY POLE ELEVATION EXISTING UTILITY POLE 1 � SHEET NUMBER C-2B SCALE: 3/16" = 1'-0" (11x17 SIZE) 3/8" = 1'-0" (22x34 SIZE) 2 ELEVATION DETAIL C-2B SCALE: 2" = 1'-0" (11x17 SIZE) 1" = 1'-0" (22x34 SIZE) C� 2B N OTE: USE OF SCHEDULE 40/80 CONDUIT OR RIGID CONDUIT SHALL BE DETERMINED BY THE UTILITY PROVIDERS REQUIREMENTS. verizon POLE MOUNTING BRACKET (ERICKSON P/N: PBAL-12 OR UTILITY POLE 1275 JOHN STREET, SUITE 100 ANTENNA (JIMA P/N: APPROVED EQUAL) (TYP OF 2) 0 WEST HENRIETTA, NY 14586 CX200M1224-3Hxy) ° PROPOSED EATON BRP12B100R I ® ° ® 0 ELECTRIC PANEL OR APPROVED EQUAL ° PROPOSED 1 /4"x20 3/4" fectonic LONG BOLT (TYP OF 3) PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. Tectonic Engineering Consultants, Geologists do Land Surveyors, D.P.C. Project Contact Info 36 British American Blvd. Phone: (518) 783-1630 Suite 101 (800) 829-6531 ANTENNA MOUNT SLEEVE (GIMBAL) Latham, NY 12110 www.tectonicengineering.com (CONCEALFAB P/N: 900070) WO NUMBER DRAWN BY REVIEWED BY c PROPOSED P1000T 12397.060 LP SM 0 UNISTRUT 6" LONG NO. DATE ISSUE (TYP OF 2) 0 12/2/24 FOR REGULATORY POLE MOUNT BRACKET ° (CONCEALFAB P/N: 007951 OR APPROVED EQUAL) ° 1 /4"x1 " WOOD SCREW (TYP OF 4/BRACKET) RELEASED BY DATE S.S. 1 /4"-20x3/4" CARRIAGE BOLT, PROPOSED 1 /4%20 FLAT WASHER, 8c NYLON LOCK NUT (INCLUDED WITH BRACKET) CHANNEL NUT (TYP OF 3) UTILITY POLE 0 TO PROPOSED METER SOCKET, PROPOSED 1 /4"x2" BE VERIFIED IN FIELD MILBANK P/N/ U2048-RL (OR LAG SCREW n OF NjE APPROVED EQUAL CONFORMING TO I \ '�� q UTILITY COMPANY STANDARDS) r�P � ��Tj, �9 c 1 POLE— TOP ANTENNA MOUNTING 2 METER MOUNTING DETAIL 3 LOAD CENTER MOUNTING DETAIL i C-3 SCALE: NTS C-3 SCALE: NTS C-3 SCALE: 4" = 1'-0" (11x17 SIZE) fib 087501 fG� 2" = 1'-0" (22x34 SIZE) R�FESSMO��� UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN BEARING THE SEAL OF A LICENSED ENGINEER OR LAND SURVEYOR IS A VIOLATION OF SECTION 7209 SHOWN MOUNTED ON AN8 POLE SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION Metro Cell Solutions MM5 PF Metro Cell Solutions O MS P CLAMP, STRA-P. AND THRU BOLT OPTIONS LAW. [[�[ "' �y q •� { Erieeson Configuralions COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE SS�•-7 02 49 5 6X lX ■ (2)RRt111•1RRiJ32i�2121441`V442 d44T3&(2)PSU+C 0211C undo 2 Z TRADE SIZE KNOCKOUTS FOR CABLE ENTRY/ OF THE SIGNATURE AND AN ORIGINAL EMBOSSED � (1)8643 or 4•449 Uktei���U$t2)�U AC 0 orals ��- �0_[y � � SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF E111T (CROSS CI.FT RUBBER GROM-METS INCLUDED) THE PROFESSIONAL ENGINEER OR LAND SURVEYOR MV2 Micro Radio Concealment Enclosure ■ 11)aB43and(I)-M7.B d(3I PSU AC 02A38 units _ r � SHALL NOT BE CONSIDERED VALID COPIES. ■ (1)4415.(1 M 4449 and(11)22Dxf440x.9(3I PSU AC 021M rrnlrm FULLY VENTED WITH OR487 Universal Single Part Number Radio Enclosure 11)4455 arid(1)444R&(3IPSUACO2A)aunits A COA+IPLIANT PERF PA1TERh�S ■ (f)4449 and(2)220xMA4 x 3 121 PSLI AC UMB units s {Jp to(6)2203r220&221D8 or44C2M40L3 radian 25-3 1 il�1�i1Cr'tlr.[IE117 ■ (1)4i415or4125radia U 7J and . "Fulura pa 61�CamCibilityior8320VVC�andRatiio- ORIGINAL SIZE IN INCHES Gne pole mounted Radio Encb5ure For all you rradio ■ 11)R853-and(t19843it(t)4449t4)PSLF ACIDS.{1)V1 SEIX192M-4ab(1)Raycap c0nfWIL1F8ti0ns under a sin-gle part n UMb& "Pleasa see Carrlrrnseope nNyusanlamro For sddoonal canGguraUaFM * UNIVERSAL POLE REMOVABLE (2 2 x 3 4 FORMAT) • ftl4y configurable-supports varying SAFMUmp Confipuratians 24.0 MOUNTING BRACKET PANEL ACCESS ACAUTION A ounfigu ratiorts wllh a universal mounling + V I ar R2 7D01a5D 320W dual band radio,L 1 I RT4401 8AA CDIss radib,(1)RT22D1- 0 1 sulution FIMFORMATION 46A4 LAA radio-.(1) ar(21 Deft;s 2-0kW UC recffer,(1)BOX 192fiOL4WSDL11126T-0 3 3 TIansmittingAntenna(sJ Aesthetically curved [rant ■ fl)AWS+PCSAWSIPCS32OW dual bend radio,ill RT4401-fallC;BRSradfc,(1) ORIGINAL SIZE IN INCHES Radio frequency fields beyond Accepts Radios for: n l 1TT2201-4MLAAradi3, (t)-13ekh2114W9c mcdbm.itISOX19Ma-4arsa)(192UT- 777 this point MAY EXCEED the FCC ACTIVE COMMUNICATION EOUIPMENI Ericsson radlos SSt-764249586E1X 43 and tl]"zW 7! 0 (11x17 FORMAT) Occupational exposure limit. IIItH41iMAPPROOt i A310C€IS Fr port:20k'rALAAFT VERtIm [Nokia radios SSC-760249586NI X • f1)AWS+PCs or 7004M 320YV dual barldradio,(1)tfi0W dual bond radio(1) _ I � 5.2 Obeyall posted signs and Pawl:IRDOWNANTENNADYLMLIZNG09COMEC7SM704ORCALL = Samsung radios 8SC-7 0241a5&6S1X RT4-aal aSOX1 2604,ill+Tz215T43101-48A a akr�aio.{1sor(2}oelta akwac p g � � RadiaComparibiGtyl iec.,;�er_(1�S1ax1926O�3+sax192$T�3 a„d(1}E�ayrsp i � � SITE INFORMATION ft"t} SEt� LIIC�ellrle5. VERVONV11RELESSFORPOWERSNUIDOKNWHEIFVERAPPAOAOF-1NG 5SC-71b17249581b]I4�[ • A is At 101A 1h7TH14 FT HOR17WAL ANO_IT VER'TICN. AP��a C9tlflil � _ 111 or(3}1�4V dual bend redm,{1)€tT4aFD1�9A CBRS raffia.(t)RT22D1�GA LA4 r SIR 0 S radio,(1 I ar(2)Dana 2AkVV U�C reuifiar,(1)SUS 192150-431 5I3X 1�6T-43(I) Cali Verixon at 1-800-264-6620 I;EA5E CAL LVERiZONwINELEssATv oa�asa ���Rro�Tv Ra 48_L -- r � (PRIOR to working beyond this GPERAnKO DISCOhNEGTSWCrCH The radio call ealm cuts ctosae is rated En to w°� con�eaf small cell radios and be mounted �existing "�'lvasasree��omrrrsce�erepresenl�we far adol'livrra+caadlp,ratiov�s•' F I I1 3�•� point, STATE r FUZE ID#: 16085137 5frt t15: rnelal, concrete, and x pale sxructurtzs as well as Nokia C'Onfiguraliona '- Site ID/ PSLC: ale replacements where low-visual impact is - • 14)Airsrals F fun radios I �• sLLTo+tlNaa[, P p mP de5lred. ;}a',' • 12)Dual Bard Rail ios-1 EWW and 32DU't'pkis ie�clifiers r yer zany r SuppDrteddual band radiiaw • � • M DG#: 5000931238 Unique, itle with Internal mounting system Sup -AHFIB `*ANFIC **AHLBA "AH13GA **AHBCC "ANLBBA f = Can be kitted with Rticllfiers. CammSc�pe { SITE ADDRESS diplexers and jumpers supported Reeffie4m r 2.5 'Gals "GE "CCI -Nokia FPAE TAMPER RES€STANT I TC11--"4 ��� 2-TRADE SIZE '-5� UTILITY POLE NG 11 /VZ 2 7169 sa sea Corr msecps repmsenfa im for adcftma!eonfigurabons- WITH PADLOCK HASP t• • t• System dimensioning & Configuration w KNOCKOUTS w1henw�Il �K ADJ TO 102 NELSON AVE Height r Vddth r"Ili l Volume 48 in. 1219.E mm 5124 in.(�6�,rWI�o-G"Trml)26 in 5W.4 rani)17.3 ou iL - � aa>t�-La rAr n9mauaalara-lFr-i 3 1�a a -RMQ AW SD+x+w . SERVICE , • NNECT ( i"'-'Q- ( ) � >=r.�ut can ac oorrvaotl�e Gmvreeo Pe�IWeMei R.od�i e6X 19a��3i 8a%:a3 dT�3 E7amum can acorxnmodWe•Derr,•!MW.1 MW or 2.MW rtir=&m or CCI rerheers.BE rmcHrEn OR CITY 0 F SARATO GA SPRINGS 1 Mbe (43kg)with nD 1D Tsd rrt irrsul[E d. NmMa FRAE mcffkm twee see flvaneaap+e reprcsert mlhm rtz daialb r � • 5ysi,am vvaigbil Aarpum.475Ibs(216ks)Farr loaded"{max} ■ 'A-&EMIesodor'1'rnr JJM c,rr,'rrnr Graeo.�rar aax-4-7o 1q rSFZN W rarF arrm Brown,-o' (21 2"TRADE SIZE 'wei[IhI varies on oorl!]4ffeiiOn TiKmar Part Gram,Fror IMyk Gdrer,-MiQ WNW KNOC KOLffs SARATO GA COUNTY hft.L Max.r4€ra b&b Poia OD 2,5 n k51n.QG byrdamPng(Larger dlame4er poem by steak banding? TAMPER R ESISTANT NY 12866 {4Vith Inckmkd Mourerg kit) Ulp to 12inOD Wood Pdewrth irxkded 5r'LY'Ihraeded rod Tor tivflugh hafting >rO$CREW$ NOTE: LFV-ar,s wL pDurder teat Various ccAw opbonr.av3ilavho. r l + - a..o SHEET TITLE Finish '1' for Light Grey, '2'far Green '3' For Black '4' FDr&awn. '6'for Fairfax Bronn '8' 1 . CONTRACTOR TO FURNISH AND INSTALL PHENOLIC Federal Perk Broom. '9'for Me9allrc Silver. 'W For Wh1le LABEL APPLIED TO LOAD CENTER. r i - _ �� ---a 1H - POLE MOUNT DETAILS Hack=(2')2'Trade Size Knockouts 1 �r..rr�r 4s��� SSC-760249W6X I X Paved Fiber Inpul Conduil Bat(2)2'Trade Sae Itnockaum �. MUWU� 11i',ETROCELL RADIO CONCEALMENT2. ATTACH RF "CAUTION" AND "INFORMATION" SIGNAGE Top:(2)2-Trade s;xelCnnekauls w MICRO V2 SOLUTION TO FACE OF UTILITY POLE USING 1 " WOOD SCREWS. MSC-Sn-REIMI-21-00s-04 OP2C19Cairrr:cMm.Ww-Alughtzrewn, Mbmiff limn* liladh}0.-rr -WEnw..; .N:. �, R;�1.1.1, :;rr MC-Sp-REMI-21-QU3-0.1 m.OIS�R+rrrx^pe 'mAllr#'brewrvr] A.I1rmhmrro %*EI'Dedryd-crwarereosJerm traoenuraarepeclwdi.-aGxwmLEexppc M&paofWwdrrmarer_i=.c ^,r7r7crtlh..� ltwi M z socem3rks re-zmctr err M CanrrrS_ope Al!%pxYlca Rona mae cubiecl La charge wrtnmM mUrm ear eras vrww aoavr+zao corn firt1w nmi cwmnl wMwrn WorL U:Ym jmjw Jr Ef T! COMMSCOPE xx a yarn w m rnccops ray Lhe mosr rurvm iRPmT mlrn D1F-aw+1f9�w- 3. RF SIGNS ARE APPROXIMATELY 6"x7.5" IN SIZE. 4 SHEET NUMBER 4 PROPOSED SIGNAGE 5 EQUIPMENT SHROUD DETAILS C-3 SCALE: NTS C-3 SCALE: NTS C�3 #2 SOLID TINNED BARE COPPER WIRE GRADE II 00 verizon z z w NONE ~ EXOTHERMIC WELD (TYP) ANTENNA MOUNT GROUNDING COAX GROUND Q ANTENNA MOUNT 1275 JOHN STREET, SUITE 100 CONDUCTORS. #6 AWG STRANDED, KIT (TYP) WEST HENRIETTA, NY 14586 INSULATED AND COPPER CABLE, COMPRESSION CONNECTION SECURED TO POLE AND ANTENNA PROPOSED VERIZON BY CONTRACTOR (TYP) MOUNT USING UV RATED CABLE TIES WIRELESS ANTENNA ■ GROUND ROD, COPPER ' ANTENNA GROUNDING CONDUCTORS. #6 SECONDARY CLAD STEEL ROD, MIN Tectonic AWG STRANDED INSULATED AND COPPER '�:` 0 5/8" DIA. X 8'-0" LONG CABLE SECURED TO POLE AND ANTENNA PRACTICAL SOLUTIONS.EXCEPTIONAL SERVICE. N (TYP OF 2) Tectonic Engineering Consultants, Geologists do Land Surveyors, D.P.C. MOUNT USING UV RATED CABLE TIES Project Contact Info . 36 British American Blvd. Phone: (518) 783-1630 Suite 101 (800) 829-6531 ••, I Latham, NY 12110 www.tectonicengineering.com I I 6' MIN WO NUMBER DRAWN BY REVIEWED BY EQUIPMENT 12397.060l F LPJ 1 SM ::1 SHROUD NOTE: NO. DATE ISSUE 0 12/2/24 FOR REGULATORY GROUND ROD SHALL BE DRIVEN VERTICALLY, BOND MAIN GROUND TO NEUTRAL -54DC CABLE NOT TO EXCEED 45 DEGREES FROM VERTICAL. WIRE OF SECONDARY TRIPLEX ANTENNA COAX JUMPERS F- — — — — — — — — — — — PROPOSED INSULATED (TYP OF 16) P—CLIPS/STRAPS OR �'--- -- ------ SMALL CELL 3 GROUND ROD DETAIL STAPLES PLACED 18" APART I C BAND RRH I E-1 SCALE: NTS I I I cn _-- -- -I_-- _ HI—BAND I o RELEASED BY DATE RR P HH GROUND BAR WITHIN SHROUD I POWER I o MODULE I PROPOSED HOMERUN GROUND WITH #2 DOUBLE C-TAP OR COLOR CODED I I AWG COPPER INSULATED OR QW TINNED LONG BARREL DOUBLE LUG � _ - - _ _ _ - - - - CONNECTION WITH NON OXIDIZING SOF NEyI, PROPOSED COMPOUND (TYP) �P� M,qp k PROPOSED HOME RUN GROUND MOPT TERMINAL 9 WIRE, #2 AWG COPPER (BY OTHERS) * co INSULATED OR #2 TINNED #6 AWG INSULATED GROUND TO LOACENTER m HOME RUN FROM ALL CABLES z� z I AND METALLIC OBJECTS O NEUTRAL aA 0$750-1 BONDING SCREW L1 L2 N0 EsstioN O METER PROPOSED PROPOSED HOME RUN GROUND WIRE, EQUIPMENT #2 AWG COPPER SOCKET GROUND BUS UNAUTHORIZED ALTERATION OR ADDITIONS TO A PLAN SHROUD 120/240V BEARING THE SEAL OF A LICENSED ENGINEER OR LAND INSULATED OR #2 TINNED SURVEYOR IS A VIOLATION OF SECTION 7209 1 SUPPLY CABLE PROPOSED LOAD CENTER SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION GRADE LAW. (TYP) O (EATON P/N: BRP12B100R) COPIES OF THIS DOCUMENT WITHOUT A FACSIMILE O ; OF THE SIGNATURE AND AN ORIGINAL EMBOSSED o GROUND ROD (TYP) SEAL OR ORIGINAL STAMP IN BLUE OR RED INK OF THE PROFESSIONAL ENGINEER OR LAND SURVEYOR PROPOSED •- ' SHALL NOT BE CONSIDERED VALID COPIES. . LOAD CENTER PROPOSED GROUNDING ELECTRODE GROUND LINE #2 AWG COPPER CONDUCTOR. #2 AWG STRANDED, INSULATED 0 1 COPPER CABLE TO GROUND BUS PROPOSED METER ORIGINAL SIZE IN INCHES 2 GROUNDING RISER DIAGRAM 4 LOAD CENTER GROUNDING (22x34 FORMAT) E-1 SCALE: NTS E-1 SCALE: NTS 0 1 #6 AWG INSULATED GROUND TO HOME RUN FROM ALL CABLES ORIGINAL SIZE IN INCHES AND METALLIC OBJECTS (11 x17 FORMAT) SITE INFORMATION PROPOSED 1/2" HIGH IMPACT PVC PROPOSED SMALL CELL SIROS U—GUARD (U—MOLDING) MOLDING C—BAND MMU TO COVER GROUND DOWN WIRE PROPOSED VERIZON WIRELESS 100A LOAD FUZE ID#: 16085137 ALONG BOTTOM 8' OF POLE CENTER (EATON P/N: BRP12B100R) (2) DC CABLE (DELTA P/N 3799423700-S) M DG#: 5000931238 EXISTING GRADE (1 ) AC CABLE (DELTA SITE ADDRESS PROPOSED 100A METER SOCKET - - STREET SIDE 20A P/N 3799919300-S) MICRO (MILBANK P/N: U2048-RL OR UTILITY POLE NG 11 VZ 2 _ APPROVED EQUAL BY UTILITY PROVIDER) 2P P RRH ADJ TO 102 NELSON AVE III—III—III-1 .. kII III III 111-111� �' II—III—III II I-I' IT 111T1=11111 DELTA ADVANTAGE P P -ITI—ITI=ITI=1 h d I 1=1 11=1 11=; A C/D C M O D U L E 111=� � - 111 =11 , P CITY OF SARATOGA SPRINGS 1 T 1—ITI—ITI—ITI i I I_I 11-111-111- R R H —ITI—I 1-1 1=PI i=111=111=ITI=1 100A METER BY SARATO GA COUNTY III—I�I—I�I—I�1= -ITI-1�1-1�1 kI�I1111111TII�IITII�, PROPOSED GROUND UTILITY PROVIDER 1 1 /2 C W/ (3) #1 =1Ti—ITI-1 ITI—IT1-1T ITI 1� =1T1=1T1=1T1; ROD (TYP OF 2) — - -T klll=III=III= -1T—IITII-I ,n, =1i1=1i1-1 (SEE DETAIL 3/E-1) N PROPOSED HI-BAND RRH NY 12866 'I=1 I I—III—III—III—III—I I' 1Ti„I ITi IT-I P P P P P SHEET TITLE 1 -1 /2" CONDUIT W/ (3)# 1 . CONTRACTOR L ELECTRICAL & GROUNDING TO ROUTE CONDUIT TO THE HEIGHT OF THE E DIAGRAMS & DETAILS SECONDARY OHW AND SPOOL 10' OF CONDUCTOR ABOVE THE CONDUIT. SPLICE TO SINGLE PHASE SERVICE TO BE 4 M PERFORMED BY UTILITY PROVIDER. ; SHEET NUMBER 6 -0 s n CONTRACTOR TO UTILIZE PENETROX _ 1 5 UTILITY POLE GROUNDING DETAIL (OR APPROVED EQUAL) ON ALL ONE LINE DIAGRAM CONNECTIONS WITHIN METER SOCKET E-1 SCALE: 3/16" = 1'-0" (11 x17 SIZE) INIE-1 SCALE: NTS 3/8" = 1'-0" (22x34 SIZE)